HomeMy WebLinkAboutKING SOOPERS #146 MIDTOWN GARDENS MARKETPLACE - PDP200012 - - DRAINAGE REPORTPREPARED FOR: Dillon Companies/King Soopers, Inc. 55 Tejon Street Denver, Colorado 80223 Phone: (303) 778-3053 PREPARED BY: Galloway & Company, Inc. 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 DATE: July 28, 2020 REVISED: October 7, 2020 MIDTOWN GARDENS MARKETPLACE KING SOOPERS STORE #146 Fort Collins, Colorado PRELIMINARY DRAINAGE REPORT FC Water Utilities Comments Matt Simpson 10/29/2020 masimpson@fcgov.com Galloway Comment Responses Galloway & Company, Inc.Page 2 of 20 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 •GallowayUS.com Galloway & Company, Inc.Page 3 of 20 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 •GallowayUS.com PRELIMINARY DRAINAGE REPORT Midtown Gardens Marketplace King Soopers Store #146 Legal Description Lots 1,2, and 4 of K-Mart Plaza, and all of Lot 2 of the extension of K-Mart Plaza, situated in the Southeast 1/4 of Section 23, Township 7 North, Range 69 West, of the 6th Principle Meridian, City of Fort Collins, County of Larimar, State of Colorado. Preparation Date July 28, 2020 Revised Date October 7, 2020 Prepared for Dillon Companies/King Soopers, Inc. 55 Tejon Street Denver, Colorado 80223 Phone: (303) 778-3053Client Address City, State, Zip Prepared by:Reviewed by: ________________________________________ ____________________________ Name Name Galloway & Company, Inc.Page 4 of 20 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 •GallowayUS.com Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 5 of 20 ENGINEER’S STATEMENT I hereby attest that this report and plan for the preliminary drainage design for Midtown Gardens Marketplace was prepared by me or under my direct supervision, in accordance with the provisions of the Fort Collins Stormwater Criteria Manual. I understand that the City of Fort Collins does not and will not assume liability for drainage facilities designed by others. Phil Dalrymple, PE # 41171 Date For and on behalf of Galloway & Company, Inc. DEVELOPER’S CERTIFICATION “King Soopers, Inc. hereby certifies that the drainage facilities for Midtown Gardens Marketplace shall be constructed according to the design presented in this report. I understand that the City of Fort Collins does not and will not assume liability for the drainage facilities designed and/or certified by my engineer and that the City of Fort Collins review))s drainage plans pursuant to the Municipal Code; but cannot, on behalf of Midtown Gardens Marketplace, guarantee that final drainage design review will absolve King Soopers, Inc. and/or their successors and/or assigns of future liability for improper design.” Authorized Signature Date King Soopers, Inc. Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 6 of 20 I. General Location and Existing Information ............................................................................................ 7 Location ...................................................................................................................................... 7 Description of Property ................................................................................................................ 7 II. Master Drainage Basin Description ...................................................................................................... 7 Major Basin Description .............................................................................................................. 7 Sub- Basin Description ................................................................................................................ 8 III. Floodplain Information ........................................................................................................................ 8 IV. Project Description ............................................................................................................................. 8 V. Drainage Design Criteria ..................................................................................................................... 8 Regulations ................................................................................................................................. 8 The Four Step Process (Low Impact Development) ..................................................................... 9 Development Criteria Reference and Constraints ........................................................................ 9 Hydrologic Criteria .................................................................................................................... 10 Hydraulic Criteria ...................................................................................................................... 10 VI. Proposed Drainage Facilities ............................................................................................................ 11 General Concept ....................................................................................................................... 11 Specific Details ......................................................................................................................... 11 VII. Variance Requests .......................................................................................................................... 13 VIII. Erosion Control .............................................................................................................................. 13 Construction Material & Equipment ........................................................................................... 14 Maintenance ............................................................................................................................. 14 IX. Conclusions ..................................................................................................................................... 14 Compliance with Standards ....................................................................................................... 14 Variances .................................................................................................................................. 14 Drainage Concept ..................................................................................................................... 14 VI. References....................................................................................................................................... 15 VII. Appendices ..................................................................................................................................... 16 A.Exhibits & Figures ........................................................................................................... 16 B.Hydrologic Computations ................................................................................................ 16 C.Hydraulic Computations .................................................................................................. 16 D.Drainage Maps ............................................................................................................... 16 TABLE OF CONTENTS Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 7 of 20 I. General Location and Existing Information Location Midtown Gardens Marketplace (hereafter referred to as “the site” or “project site”) will be located at the northwest corner of South College Avenue and West Drake Road. It is bounded on north by an existing commercial development; on the south by West Drake Road (including a Jiffy Lube and Loaf ‘N Jug to remain); on the east by College Avenue; and on the west by the MAX-BRT Bus Line. Spring Creek is located north of the site. More specifically, the site is located in the Southeast Quarter of Section 23, Township 7 North, Range 69 West in the City of Fort Collins, County of Larimer and State of Colorado. Refer to Appendix A for a Vicinity Map. Description of Property The project site is approximately 11.34 acres, and consists of a currently vacant Kmart store, a small retail building at the northeast corner of the site, and an existing Loaf N’ Jug fueling station. Existing grades on the site range from one to four percent, with historic runoff generally draining to the north and east across the site. There are no major drainage ways passing through the project site. According to the USDA NRCS Web Soil Survey, ‘Nunn Clay loam, 0 to 1 percent slopes’ covers the entire project site. This soil is associated with Hydrologic Soil Group (HSG) ‘C’. HSG ‘C’ soils have a slow infiltration rate when thoroughly wet and consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Refer to Appendix A for additional soils information. The Midtown Gardens Marketplace will be developed in one phase and is approximately 11.34 acres. The existing vacant Kmart building along with the vacant retail building at the northeast corner of the site will be removed. A new King Soopers Marketplace will replace the Kmart, while a new King Soopers fueling station will replace the vacant retail building. The existing parking lot will be reconstructed to accommodate the new structures. The lot containing the Loaf N’ Jug will remain vacant for future development but is included in this report in its developed condition. During the water quality storm event, surface runoff will flow into one of several stormwater quality features located on the site. The stormwater quality features include the use of an underground storage system. During the minor (i.e., 2-year) and major (i.e., 100-year) storm events, runoff volume in excess of the water quality event will bypass the WQ system and enter the existing storm sewer system. II. Master Drainage Basin Description Major Basin Description The project site is located in the Spring Creek drainage basin. According to the City of Fort Collins website (http://www.fcgov.com/utilities/what-we-do/stormwater/drainage-basins/spring-creek-basin), this basin “is a major watercourse that flow from Spring Canyon Dam at Horsetooth Reservoir to its confluence with the Poudre River. The basin is dominated by residential development, but also includes open space, parks, and isolated areas of commercial and industrial development.” On-site detention storage is not required for the site because the site is mostly impervious and the proposed development does not trigger detention requirements. While detention is not required, the applicant has coordinated with the City to provide 100-year detention for the proposed development and small retail on SE corner of site (Lark Burger building) please update based on design with detention. Corrected as noted Corrected as noted Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 8 of 20 to alleviate the impact to the downstream system. The Impervious Area Exhibit in Appendix D, which shows a net decrease in total impervious area form the existing to proposed condition. Water quality for the site has been provided in accordance with the City of Fort Collins LID requirements for the redeveloped portions of the site. A Water Quality and detention structure has been sized for the redeveloped portions of the site in the form of an underground extended detention basin, herein referred to as Pond A. Preliminary calculations for underground basin have been provided, and can be found in Appendix C. Sub- Basin Description The site historically drains north and east towards the adjacent commercial development and College Avenue. There are several storm inlets along the northern property line and throughout the site which collect runoff. These storm sewer mains ultimately drain to Spring Creek. At the request of Fort Collins Stormwater Master Planning, The historic drainage pattern will be modified to convey flows from the site to the existing storm drain system at the southeast corner of the site in College Ave and flowing east along Princeton Road, rather than to the existing storm drain system on the adjacent property to the north. Minor flows will be conveyed off-site at the site boundaries, which is consistent with the historic drainage pattern. At the sub-basin level, no offsite runoff is anticipated to enter the site, with the exception of a small amount of runoff at the southwest corner or the site coming from the MAX/BRT bus station, which is currently tributary to the site. A portion of the site along W Drake Rd. and S College Ave. will drain offsite, which is consistent with the current drainage pattern. The site has been broken into four basins, each with their own set of sub-basins. A description of each basin and their characteristics can be found later in the report. There are no irrigation, reservoir, or other facilities that influence, or are influenced by, the local drainage. III. Floodplain Information The project site is shown on FEMA Map Number 08069C0987G (refer to Appendix A for FEMA Firmette). This map shows that the project is not impacted by an existing floodplain/floodway. Refer to Appendix A for a copy of the Firmette. IV. Project Description The Midtown Gardens Marketplace will be developed in one phase and is approximately 11.34 acres. The existing vacant Kmart building along with the vacant retail building at the northeast corner of the site will be removed. A new King Soopers Marketplace will replace the Kmart, while a new King Soopers fueling station will replace the vacant retail building. The existing parking lot will be reconstructed to accommodate the new structures. The lot containing the Loaf N’ Jug will remain vacant for future development but is included in this report in its developed condition. V. Drainage Design Criteria Regulations This preliminary drainage design presented herein is prepared in accordance with the Fort Collins Stormwater Criteria Manual, November 2017 (FCSCM), the Mile High Flood District (MHFD) Urban Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 9 of 20 Storm Drainage Criteria Manual, January 2016 (USDCM), and Chapter 10, Flood Prevention and Protection, of the Fort Collins City Code. No other drainage reports could be provided for the site by the City of Fort Collins. The Four Step Process (Low Impact Development) At this preliminary stage of the design process, we developed a commensurate implementation of the ‘The Four-Step Process’ for stormwater quality management. Ordinance No. 007, 2016 requires that no less than seventy-five percent (75%) of any newly developed or redeveloped area be treated using one or a combination of LID techniques. As previously mentioned, the developer proposes to replace the existing Kmart with a new King Soopers Marketplace. The runoff for the modified areas collected onsite will be treated using and underground LID water quality system. This LID system will address 100% of the captured volume rather than using a combination of LID and standard methods. Appropriate spill containment will be provided in the area of the proposed fuel station. Step 1 - Employ runoff reduction practices The attached drainage map (see Appendix D) delineates the proposed drainage basins, each of which drains to a proposed underground water quality system, Pond A. Underground systems are an accepted LID method when surface BMPs are infeasible, which consist of an underground chamber that provide stormwater quality treatment via sedimentation, screening, filtration, and other physical and chemical processes. Step 2 - Implement BMPs that provide a Water Quality Capture Volume (WQCV) Due to site constraints, and underground storage system will provide the necessary Water Quality Capture Volume (WQCV). Step 3 - Stabilize drainageways The developed runoff generated by the proposed redevelopment will drain to an existing storm drain system located along the west side of South College Avenue. This system drains north and outfalls into Spring Creek. Our work assumes that an appropriate level of stabilization exists at the outfall into Spring Creek. Step 4 - Implement site specific and other source control BMPs Site specific considerations such as material handling/storage and other site operations will be addressed in the Stormwater Management Plan (SWMP). Development Criteria Reference and Constraints This preliminary drainage design presented herein is prepared in accordance with the Fort Collins Stormwater Criteria Manual, November 2017 (FCSCM) and the Mile High Flood District (MHFD) Urban Storm Drainage Criteria Manual, January 2016 (USDCM). No other drainage reports could be provided for the site by the City of Fort Collins. Existing runoff for the proposed site generally drains to the north and east across the site. The majority of the on-site runoff is captured by an existing storm sewer system which has three connections to the offsite system downstream. The site drains into an existing 24” storm pipe just north of the site (2 connections), and a 15” storm pipe along College Avenue. Capacity calculations for the proposed and existing portions of the storm sewer system have been provided in Appendix C. Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 10 of 20 Hydrologic Criteria For urban catchments that are not complex and are generally 160 acres or less in size, it is acceptable that the design storm runoff be analyzed using the Rational Method. The Rational Method is often used when only the peak flow rate or total volume of runoff is needed (e.g., storm sewer sizing or simple detention basin sizing). The Rational Method was used to estimate the peak flow at each design point. Routing calculations (i.e., time attenuation) that aggregate the basins draining to a specific design point are include in the Rational Method calculations in Appendix B. The Rational Method is based on the Rational Formula: Q = CiA Where: Q = the maximum rate of runoff, cfs C = a runoff coefficient that is the ratio between the runoff volume from an area and the average rate of rainfall depth over a given duration for that area i = average intensity of rainfall in inches per hour for a duration equal to the Time of Concentration (Tc) A = area, acres Runoff Coefficients were determined based on Tables 3.2-1, 3.2-2, and 3.2-3 of the the FCSCM. The one-hour rainfall Intensity-Duration-Frequency tables for use with the Rational Method of runoff analysis are provided in Table 3.4-1 of the FCSCM. The 2-year and 100-year storm events serve as the basis for the drainage system design. The 2-year storm is considered the minor storm event. It has a fifty percent probability of exceedance during any given year. The 100-year storm is considered the major storm event. It has a one percent probability of exceedance during any given year. The 2-year drainage system, at a minimum, must be designed to transport runoff from the 2-year recurrence interval storm event with minimal disruption to the urban environment. The 100-year drainage system, as a minimum, must be designed to convey runoff from the 100-year recurrence interval flood to minimize life hazards and health, damage to structures, and interruption to traffic and services. Hydraulic Criteria There are three on-site basins which drain to the proposed storm sewer system, which are identified in the proposed drainage map (Appendix D) as Basins A, B, and C. Runoff from each basin will be collected by storm sewer inlets and pipes and conveyed offsite to the existing storm drain system in College Ave at the southeast corner of the site. Basin A is collected by a storm sewer system on the west, south, and east sides of the proposed building. Basins B & C are collected by storm sewers on the east side of the building. Each of these three systems convey flows to a proposed underground detention system at the southeast corner of the site for water quality, detention, and attenuation, which then releases the detained flows into the existing storm drain system in College Ave. Additional areas for the site not collected by the proposed storm drain system are designated as Off- Site Basins (OS) and will drain offsite to existing storm drain infrastructure, consistent with the existing drainage pattern. Runoff from these offsite basins will be released undetained toward W Drake Rd, S College Ave, and existing inlets north of the site. Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 11 of 20 Inlet Capacity Analysis Inlet calculations are not required to be included with this preliminary report and will provided with the Final Drainage Report. Storm Drain Capacity Analysis The preliminary storm drain system is typically sized to convey the sum of the 100-year developed runoff at each design point draining into the system. The pipes are sized to convey this runoff without surcharging (full-flow capacity). This method should provide a conservative estimate of total runoff and pipe sizes. It appears that the 100-year developed runoff for the site will not be able to be conveyed in the existing storm sewer system at the north end of the site, per the existing drainage pattern. Therefore, the City has granted that the proposed storm sewer system can be re-routed such that it will be detained and treated for water quality on site, then released at a controlled 2-year historic rate into the existing storm drain system in College Ave at the southeast corner of the site. The preliminary design of the storm sewer system for the site has been sized to handle the 100-year storm event. For this preliminary Drainage Study, Flowmaster was used to size the proposed system, and provide capacity calculations, using a minimum slope of 0.5%. The Flowmaster summaries in Appendix C show the max flows for the proposed storm drains at the minimum slope. VI. Proposed Drainage Facilities General Concept This final design presents the detailed design of the proposed system for collecting and conveying developed runoff from current and proposed development at the Midtown Gardens Marketplace site to the Stormwater quality and detention features and offsite systems. The existing site runoff drains to existing storm sewer inlets within the parking lot. The proposed design matches this existing drainage pattern and includes the implementation of and underground StormTech system to provide water quality and detention for the site. Specific Details The site has been broken into three basins, each with their own set of sub-basins. A description of each basin and their characteristics can be found below. The intent of the drainage design is to have the runoff from the majority of the site collected and drain through a water quality and detention facility prior to entering the existing storm sewer system offsite. Pond A has been sized based on the City of Fort Collins LID requirements for the necessary portions of the site, which will be located at the downstream connection point to the existing storm drain system at the southeast corner of the site in College Ave. The released stormwater from the site will travel in the existing storm sewer system, and ultimately reach Spring Creek. Basin A Basin A consists of the west, south, and southeast portions of the site and is comprised of 13 sub- basins. The basin includes the proposed building, the south and southeast parking lots, the areas to the west of the proposed building, and the existing Loaf N’ Jug site (which will remain vacant as part of this project but is included in the drainage calculations in its future developed condition). Runoff from Basin A will be collected by the proposed storm sewer system and conveyed to the southeast corner of the site to the proposed underground detention facility, and ultimately discharge into the existing storm sewer system in College Ave. Basin B Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 12 of 20 Basin B consists of the northeastern portion of the site between the building and the fuel center and is comprised of 3 sub-basins. The basin includes the portion of the east parking lot at the building entry and the access drive to College Ave. Runoff from Basin B will be collected by the proposed storm sewer system and conveyed south to the southeast corner of the site to the proposed underground detention facility, and ultimately discharge into the existing storm sewer system in College Ave. Basin C Basin C consists of the northeast corner of the site and is comprised of 5 sub-basins. The basin includes the proposed fuel center and the northeast portion of the main parking lot. Runoff from Basin B will be collected by the proposed storm sewer system and conveyed south to the southeast corner of the site to the proposed underground detention facility, and ultimately discharge into the existing storm sewer system in College Ave. Offsite Basins The remainder of the site consists of basins that flow offsite, as is current with the existing drainage pattern. These basins are located along W Drake Rd, S College Ave, and the northern portion of the site between the building and the adjacent property. These basins include sidewalk, tree lawn, and landscape areas between the sidewalk and the parking lot, and access drives off of S College Ave and W Drake Rd, as well as paved areas joining the site with the adjacent property. Flows from these areas historically sheet flow to either the existing roadways adjacent to the site or to existing inlets on the adjacent property north of the site, and ultimately drain to an existing inlet located in College Avenue near the northeast corner of the site and an existing inlet at the northwest corner of College and Drake. The characteristics of the tributary areas draining to these inlets will remain virtually the same, so anticipated flow rates generated should be the same and not negatively impact the existing storm sewer system. Once in the existing storm sewer inlets, the stormwater from this basin is conveyed through the existing storm sewer system and ultimately reaches Spring Creek. Water Quality Enhancement The site has been divided into multiple drainage basins as described above. Runoff from each basin will be collected and conveyed to Pond A, which provides water quality treatment in the form of and underground LID system. The LID Summary Table provided in Appendix B identifies and compares the on-site impervious area of the existing and proposed conditions. In the existing condition, there is approximately 10.59 acres of impervious area within the limits of disturbance. Of that area, 8.69 acres of impervious area flow to the on-site storm drain system. The remaining 1.91 acres flow offsite and does not contribute to the on-site storm system. In the proposed condition, there is approximately 10.54 acres or impervious area within the limits of disturbance. Of that area, 9.74 acres of impervious area flow to the on-site storm drain system. The remaining 0.80 acres flow offsite and does not contribute to the on-site storm system. Therefore, the proposed site will increase the total amount of treated impervious area while reducing the overall impervious area. In conformance with the requirement identified under the Four Step Process to treat at least 75% of impervious areas through LID methods, 100% of the on-site proposed impervious areas will be treated through the proposed underground detention system. A summary of the Impervious areas can be found in Appendix B, and a delineation of the on-site area boundaries for the existing and proposed conditions can be found in the Impervious Area Exhibit in Appendix D. More information for the calculation and sizing of the water quality system is provide in Appendix B. I think 10.54 acres of Imp. Area is your required treatment area. How much of this 10.54 is on-property? Off-property areas do not count into WQ/LID for a redeveloping site. Please discuss with me if this does not make sense. This sounds like you are short 0.8 acres of treated impervious area. (10.54 - 9.74 = 0.80) I am unclear if the project is providing the required water quality treatment area. Please move the WQ and LID table to the report body here. I have made more comments on this table in the appendix. Onsite impervious areas (new or modified) require WQ treatment. It doesn't matter where they flow to. This paragraph has been updated to address these based on discus- sions with Matt Simpson Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 13 of 20 Water Quality treatment will be provided in the isolator rows of the StormTech detention system. The total volume of water quality has been calculated based on a release rate of 0.35 gpm/sf of storage area. Structures within the StormTech system will divert flows in excess of the water quality event to the remainder of the detention system. A summary of the water quality system calculations can be found in Appendix B. Storm Water Detention The City has requested that the underground systems mentioned above be utilized to provide additional detention storage to alleviate flooding issues downstream of the site. The proposed underground StormTech system, Pond A, will be designed as an Extended Detention Basin for the site, including Water Quality treatment and 100-year detention with a controlled 2-year historic release rate of 0.50 cfs/acre. Required volumes were determined using the Modified FAA Method. Below is a summary of the total storage proposed for each system. A tabulation of the stage storage volume for Pond A can be found in Appendix C. StormTech Detention Facility Summary Facility I.D. WQCV Provided (cf) Additional Storage Volume Provided (cf) Total Volume Required (cf) Total Volume Provided (cf) Pond A 14,796 72,581 86,940 87,377 VII. Variance Requests No variances are being requested with the proposed improvements described herein. VIII. Erosion Control A General Permit for Stormwater Discharge Associated with Construction Activities issued by the Colorado Department of Public Health and Environment (CDPHE), Water Quality Control Division (WQCD), will be acquired for the site. A Stormwater Management Plan (SWMP) should be prepared to identity the Best Management Practices (BMPs) which, when implemented, will meet the requirements of said General Permit. Below is a summary of SWMP requirements which may be implemented on-site. The following temporary BMPs may be installed and maintained to control on-site erosion and prevent sediment from traveling off-site during construction: · Silt Fence – a woven synthetic fabric that filters runoff. The silt fence is a temporary barrier that is placed at the base of a disturbed area. · Vehicle Tracking Control – a stabilized stone pad located at points of ingress and egress on a construction site. The stone pad is designed to reduce the amount of mud transported onto public roads by construction traffic. · Straw Wattles – wattles act as a sediment filter. They are a temporary BMP and require proper installation and maintenance to ensure their performance. · Inlet protection – Inlet protection will be used on all existing and proposed storm inlets to help prevent debris from entering the storm sewer system. Inlet protection generally consists of straw wattles or block and gravel filters. Add -tributary area -imperviousness -release rate updated table as requested Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 14 of 20 Compliance with Erosion Control Criteria and all Erosion Control Materials in greater detail will be provided with the Final Drainage Report Construction Material & Equipment The contractor shall store all construction materials and equipment and shall provide maintenance and fueling of equipment in confined areas on-site from which runoff will be contained and filtered. Maintenance The temporary BMPs will be inspected by the contractor at a minimum of once every two weeks and after each significant storm event. The property owner will be responsible for routine and non-routine maintenance of the temporary BMPs. Routine maintenance includes: · Remove sediment from the bottom of the temporary sediment basin when accumulated sediment occupies about 20% of the design volume or when sediment accumulation results in poor drainage. · Debris and litter removal-remove debris and litter to minimize outlet clogging and improve aesthetics as necessary. · Inspection of the facility-inspect the facility annually to ensure that it functions as initially intended. · Cleaning and repair of BMP’s is required when sediment has built up or the BMP is not working properly. IX. Conclusions Compliance with Standards The design presented in this final drainage report for the Midtown Gardens Marketplace has been prepared in accordance with the design standards and guidelines presented in the Fort Collins Stormwater Criteria Manual and the MHFD Urban Storm Drainage Criteria Manual. Variances No variances are being requested with the proposed improvements described herein. Drainage Concept The proposed Midtown Gardens Marketplace storm drainage improvements should provide adequate collection and Water Quality protection for the developed site. The proposed drainage design will sufficiently drain the proposed development and should not negatively impact the existing condition of the overall storm drainage system. Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 15 of 20 VI. References 1. Fort Collins Stormwater Criteria Manual, November 2017 2. Urban Storm Drainage Criteria Manual, Mile High Flood District, January 2016 (with current revisions). 3. Flood Insurance Rate Map – Larimer County, Colorado and Incorporated Areas Community Panel No. 08069C0987G, Effective May 2, 2012. 4. Soil Map – Larimer County Area, Colorado as available through the Natural Resources Conservation Service National Cooperative Soil Survey web site via Web Soil Survey 2.0. Midtown Gardens Marketplace 10/7/2020 Galloway & Company, Inc.Page 16 of 20 VII. Appendices A. Exhibits & Figures · Vicinity Map · USGS Soil Survey Data · FEMA Flood Insurance Rate Map B. Hydrologic Computations · Existing Condition Basin Summary · Existing Condition Rational Method Computations · Existing Minor and Major Storm Runoff Computations · Proposed Condition Basin Summary · Proposed Condition Rational Method Computations · Proposed Minor and Major Storm Runoff Computations · Modified FAA Calculations - Water Quality · Modified FAA Calculations – 100-Year Storage · Water Quality System Calculation Summary · LID Summary Table C. Hydraulic Computations · Flowmaster Pipe Capacity Calculations · ADS StormTech Specifications · ADS StormTech Stage Storage Summary D. Drainage Maps · Impervious Area Exhibit · Existing Drainage Map · Proposed Drainage Map Subdivision:Midtown Gardens Marketplace Project Name:King Soopers Store #146 Location:CO, Fort Collins Project No.: Calculated By:E. Mowinckel Checked By:P. Dalrymple Date:10/5/20 1 BASIN D.A.Hydrologic C2 C5 C100 L S Ti | 2-Year Ti | 100-Year L S Cv VEL.Tt COMP. Tc | 2-Year COMP. Tc | 100-Year TOTAL Urbanized Tc Tc | 2-Year Tc | 100-Year ID (AC)Soils Group Cf=1.00 Cf=1.00 Cf=1.25 (FT)(%)(MIN)(MIN)(FT)(%)(FPS)(MIN)(MIN)(MIN)LENGTH(FT)(MIN)(MIN)(MIN) EX01 1.11 C 0.92 0.92 1.00 239 1.87 4.2 2.3 0 1.00 20 2.0 0.0 4.2 2.3 239 11.3 5.0 5.0 EX02 0.14 C 0.92 0.92 1.00 85 2.60 2.3 1.3 0 1.00 20 2.0 0.0 2.3 1.3 85 10.5 5.0 5.0 EX03 1.02 C 1.03 1.03 1.00 390 1.60 2.2 3.2 0 1.00 20 2.0 0.0 2.2 3.2 390 12.2 5.0 5.0 EX04 0.33 C 0.95 0.95 1.00 190 1.61 3.3 2.2 0 1.00 20 2.0 0.0 3.3 2.2 190 11.1 5.0 5.0 EX05 0.53 C 0.95 0.95 1.00 350 1.91 4.4 2.8 0 1.00 20 2.0 0.0 4.4 2.8 350 11.9 5.0 5.0 EX06 1.22 C 0.85 0.85 1.00 340 1.00 8.5 3.4 75 0.64 20 1.6 0.8 9.3 4.2 415 12.3 9.3 5.0 EX07 2.44 C 0.92 0.92 1.00 355 1.30 5.7 3.2 285 0.41 20 1.3 3.7 9.4 6.9 640 13.6 9.4 6.9 EX08 0.44 C 0.89 0.89 1.00 140 2.39 3.5 1.7 0 1.00 20 2.0 0.0 3.5 1.7 140 10.8 5.0 5.0 EX09 0.61 C 0.72 0.72 0.90 200 1.00 10.0 5.3 0 1.00 20 2.0 0.0 10.0 5.3 200 11.1 10.0 5.3 EX10 0.34 C 0.71 0.71 0.89 90 2.62 5.0 2.7 0 1.00 20 2.0 0.0 5.0 2.7 90 10.5 5.0 5.0 EX11 0.61 C 0.83 0.83 1.00 250 2.54 5.9 2.2 0 1.00 20 2.0 0.0 5.9 2.2 250 11.4 5.9 5.0 EX12 1.05 C 0.91 0.91 1.00 160 3.08 3.0 1.6 0 1.00 20 2.0 0.0 3.0 1.6 160 10.9 5.0 5.0 EX13 0.25 C 0.95 0.95 1.00 150 2.00 2.7 1.8 0 1.00 20 2.0 0.0 2.7 1.8 150 10.8 5.0 5.0 EX14 0.11 C 0.95 0.95 1.00 100 2.00 2.2 1.5 0 1.00 20 2.0 0.0 2.2 1.5 100 10.6 5.0 5.0 EX15 0.12 C 0.95 0.95 1.00 105 2.00 2.3 1.5 0 1.00 20 2.0 0.0 2.3 1.5 105 10.6 5.0 5.0 EX16 0.59 C 0.95 0.95 1.00 240 2.00 3.4 2.3 0 1.00 20 2.0 0.0 3.4 2.3 240 11.3 5.0 5.0 EX17 0.48 C 0.95 0.95 1.00 230 2.00 3.4 2.3 0 1.00 20 2.0 0.0 3.4 2.3 230 11.3 5.0 5.0 EX18 0.53 C 0.95 0.95 1.00 235 2.00 3.4 2.3 0 1.00 20 2.0 0.0 3.4 2.3 235 11.3 5.0 5.0 EX19 0.33 C 0.95 0.95 1.00 220 2.00 3.3 2.2 0 1.00 20 2.0 0.0 3.3 2.2 220 11.2 5.0 5.0 EX20 0.15 C 0.82 0.82 1.00 460 1.17 10.7 3.8 0 1.00 20 2.0 0.0 10.7 3.8 460 12.6 10.7 5.0 EX21 0.23 C 0.83 0.83 1.00 125 0.80 6.1 2.3 0 1.00 20 2.0 0.0 6.1 2.3 125 10.7 6.1 5.0 NOTES: Ti = (1.87*(1.1 - CCf)*(L)^0.5)/((S)^0.33), S in %Cv Tt=L/60V (Velocity From Fig. 501)2.5 Velocity V=Cv*S^0.5, S in ft/ft 5 Tc Check = 10+L/180 7 For Urbanized basins a minimum Tc of 5.0 minutes is required.10 For non-urbanized basins a minimum Tc of 10.0 minutes is required 15 20 STANDARD FORM SF-2 TIME OF CONCENTRATION - EXISTING SUB-BASIN Tc CHECK KSS000018.02 DATA (URBANIZED BASINS)(Tt)FINALINITIAL/OVERLAND (Ti) TRAVEL TIME Paved areas and shallow paved swales Type of Land Surface Heavy Meadow Tillage/field Short pasture and lawns Nearly bare ground Grassed waterway H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College Drake\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports-Info\Hydrology\KSS 146_Rational_Routing - Ex.xls Page 1 of 1 10/5/2020 You need to use the Fort Collins Stormwater Criteria Manual (FCSCM) method for the Tc calcs. This is the "manning velocity method", for this method, you will need to simple assume a flow depth to compete the Tc calculation. Please see chapter 5, section 3.3 of the FCSCM. Feel free to contact me if you have questions. V=1.4/n * R^2/3 * S^1/2 Tc Calc has been up- dated Subdivision:Midtown Gardens Marketplace Project Name:King Soopers Store #146 Location:CO, Fort Collins Project No.: Calculated By:E. Mowinckel Checked By:P. Dalrymple Date:10/5/20 1 BASIN D.A.Hydrologic C2 C5 C100 L S Ti | 2-Year Ti | 100-Year L S Cv VEL.Tt COMP. Tc | 2-Year COMP. Tc | 100-Year TOTAL Urbanized Tc Tc | 2-Year Tc | 100-Year ID (AC)Soils Group Cf=1.00 Cf=1.00 Cf=1.25 (FT)(%)(MIN)(MIN)(FT)(%)(FPS)(MIN)(MIN)(MIN)LENGTH(FT)(MIN)(MIN)(MIN) A-1 0.83 C 0.92 0.92 1.00 250 1.75 4.5 2.5 100 2.00 20 2.8 0.6 5.1 3.0 350 11.9 5.1 5.0 A-2 0.50 C 0.91 0.91 1.00 200 3.00 3.5 1.8 0 1.00 20 2.0 0.0 3.5 1.8 200 11.1 5.0 5.0 A-3 0.90 C 0.82 0.82 1.00 175 1.75 5.7 2.1 0 1.00 20 2.0 0.0 5.7 2.1 175 11.0 5.7 5.0 A-4 0.23 C 0.87 0.87 1.00 125 1.50 4.2 1.8 0 1.00 20 2.0 0.0 4.2 1.8 125 10.7 5.0 5.0 A-5 1.21 C 0.89 0.89 1.00 200 2.00 4.4 2.1 0 1.00 20 2.0 0.0 4.4 2.1 200 11.1 5.0 5.0 A-6 1.08 C 0.85 0.85 1.00 280 1.90 6.4 2.5 0 1.00 20 2.0 0.0 6.4 2.5 280 11.6 6.4 5.0 A-7 0.15 C 0.95 0.95 1.00 80 7.00 1.3 0.9 0 1.00 20 2.0 0.0 1.3 0.9 80 10.4 5.0 5.0 A-8 0.28 C 0.88 0.88 1.00 60 2.00 2.5 1.1 40 0.80 20 1.8 0.4 2.9 1.5 100 10.6 5.0 5.0 A-9 0.25 C 0.72 0.72 0.91 60 2.00 4.3 2.2 60 1.00 20 2.0 0.5 4.8 2.7 120 10.7 5.0 5.0 A-10 0.11 C 0.95 0.95 1.00 20 2.00 1.0 0.7 0 1.00 20 2.0 0.0 1.0 0.7 20 10.1 5.0 5.0 A-11 0.55 C 0.95 0.95 1.00 230 2.00 3.4 2.3 0 1.00 20 2.0 0.0 3.4 2.3 230 11.3 5.0 5.0 A-12 0.65 C 0.95 0.95 1.00 230 2.00 3.4 2.3 0 1.00 20 2.0 0.0 3.4 2.3 230 11.3 5.0 5.0 A-13 1.56 C 0.95 0.95 1.00 230 2.00 3.4 2.3 0 1.00 20 2.0 0.0 3.4 2.3 230 11.3 5.0 5.0 B-1 0.77 C 0.92 0.92 1.00 250 1.80 4.4 2.4 40 1.00 20 2.0 0.3 4.7 2.8 290 11.6 5.0 5.0 B-2 0.09 C 0.72 0.72 0.91 40 2.50 3.3 1.7 90 2.00 20 2.8 0.5 3.8 2.2 130 10.7 5.0 5.0 B-3 0.08 C 0.65 0.65 0.82 40 3.00 3.7 2.3 90 2.00 20 2.8 0.5 4.2 2.9 130 10.7 5.0 5.0 C-1 0.11 C 0.95 0.95 1.00 45 1.50 1.6 1.1 75 1.00 20 2.0 0.6 2.3 1.7 120 10.7 5.0 5.0 C-2 0.12 C 0.95 0.95 1.00 20 2.00 1.0 0.7 0 1.00 20 2.0 0.0 1.0 0.7 20 10.1 5.0 5.0 C-3 0.65 C 0.93 0.93 1.00 190 2.50 3.3 1.9 0 1.00 20 2.0 0.0 3.3 1.9 190 11.1 5.0 5.0 C-4 0.34 C 0.90 0.90 1.00 160 2.20 3.7 1.8 0 1.00 20 2.0 0.0 3.7 1.8 160 10.9 5.0 5.0 C-5 0.01 C 0.95 0.95 1.00 15 2.00 0.9 0.6 0 1.00 20 2.0 0.0 0.9 0.6 15 10.1 5.0 5.0 OS-1 0.51 C 0.54 0.54 0.68 50 1.75 6.1 4.6 600 0.20 20 0.9 11.2 17.3 15.8 650 13.6 13.6 13.6 OS-2 0.32 C 0.73 0.73 0.91 40 2.00 3.5 1.8 450 1.00 20 2.0 3.8 7.2 5.5 490 12.7 7.2 5.5 OS-3 0.13 C 0.92 0.92 1.00 85 4.00 2.0 1.1 0 1.00 20 2.0 0.0 2.0 1.1 85 10.5 5.0 5.0 OS-4 0.32 C 0.93 0.93 1.00 150 2.50 2.9 1.7 0 1.00 20 2.0 0.0 2.9 1.7 150 10.8 5.0 5.0 OS-5 0.71 C 0.87 0.87 1.00 170 2.00 4.5 1.9 0 1.00 20 2.0 0.0 4.5 1.9 170 10.9 5.0 5.0 OS-6 0.15 C 0.95 0.95 1.00 124 3.00 2.2 1.4 0 1.00 20 2.0 0.0 2.2 1.4 124 10.7 5.0 5.0 NOTES: Ti = (1.87*(1.1 - CCf)*(L)^0.5)/((S)^0.33), S in %Cv Tt=L/60V (Velocity From Fig. 501)2.5 Velocity V=Cv*S^0.5, S in ft/ft 5 Tc Check = 10+L/180 7 For Urbanized basins a minimum Tc of 5.0 minutes is required.10 For non-urbanized basins a minimum Tc of 10.0 minutes is required 15 20 STANDARD FORM SF-2 TIME OF CONCENTRATION - PROPOSED Paved areas and shallow paved swales Type of Land Surface Heavy Meadow Tillage/field Short pasture and lawns Nearly bare ground Grassed waterway DATA (URBANIZED BASINS)(Tt)FINALINITIAL/OVERLAND (Ti) TRAVEL TIMESUB-BASIN Tc CHECK KSS000018.02 H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College Drake\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports-Info\Hydrology\KSS 146_Rational_Routing.xls Page 1 of 1 10/5/2020 You need to use the Fort Collins Stormwater Criteria Manual (FCSCM) method for the Tc calcs. This is the "manning velocity method", for this method, you will need to simple assume a flow depth to compete the Tc calculation. Please see chapter 5, section 3.3 of the FCSCM. Feel free to contact me if you have questions. V=1.4/n * R^2/3 * S^1/2 Tc Calc has been up- dated Project Number:King Soopers Store #146 Date:10/5/2020 Project Location:CO, Fort Collins Calculations By:E. Mowinckel Checked By:P. Dalrymple Pond Description:Pond A Water Quality User Input Cell:Blue Text 1/2 2-year 5137 0.90 0.12 10.47 3.30 minutes seconds in/hr cubic feet cubic feet cubic feet acre-feet 5 300 1.43 4022 990.6 3031 0.07 10 600 1.11 6237 1981.2 4256 0.10 15 900 0.94 7917 2971.8 4945 0.11 20 1200 0.81 9088 3962.4 5125 0.12 25 1500 0.72 10090 4953 5137 0.12 30 1800 0.65 11007 5943.6 5063 0.12 35 2100 0.59 11557 6934.2 4623 0.11 40 2400 0.54 12079 7924.8 4155 0.10 45 2700 0.50 12573 8915.4 3658 0.08 50 3000 0.46 12983 9906 3077 0.07 55 3300 0.44 13505 10896.6 2608 0.06 60 3600 0.41 13886 11887.2 1998 0.05 65 3900 0.39 14309 12877.8 1431 0.03 70 4200 0.37 14422 13868.4 553 0.01 75 4500 0.35 14817 14859 -42 0.00 80 4800 0.33 14902 15849.6 -948 -0.02 85 5100 0.32 15353 16840.2 -1487 -0.03 90 5400 0.31 15494 17830.8 -2336 -0.05 95 5700 0.29 15551 18821.4 -3271 -0.08 100 6000 0.28 15805 19812 -4007 -0.09 105 6300 0.27 16002 20802.6 -4800 -0.11 110 6600 0.26 16143 21793.2 -5650 -0.13 115 6900 0.26 16553 22783.8 -6231 -0.14 120 7200 0.25 16595 23774.4 -7179 -0.16 Modified FAA Method - WQ Storage Volume Calculations Inputs | Tributary Area Output | Detention Volume Return Period for Detention Control:Required Storage, cubic feet: Catchment 'C':Required Storage, ac-ft: Average Outflow Storage Volume Storage Volume Catchment Drainage Area, ac: Release Rate, cfs: Storm Duration Time Rainfall Intensity Inflow Volume H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College Drake\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports- Info\Hydrology\KSS 146_Rational_Routing.xls Page 1 of 2 10/5/2020 does not match WQ Calc summary page - 2.4 cfs based on 91 chambers. Corrected as noted Project Number:King Soopers Store #146 Date:10/5/2020 Project Location:CO, Fort Collins Calculations By:E. Mowinckel Checked By:P. Dalrymple Pond Description:Pond A 100-Year Detention User Input Cell:Blue Text 100-year 86940 0.90 2.00 10.47 5.24 minutes seconds in/hr cubic feet cubic feet cubic feet acre-feet 5 300 9.95 28082 1570.5 26511 0.61 10 600 7.72 43576 3141 40435 0.93 15 900 6.52 55204 4711.5 50492 1.16 20 1200 5.60 63219 6282 56937 1.31 25 1500 4.98 70275 7852.5 62422 1.43 30 1800 4.52 76540 9423 67117 1.54 35 2100 4.08 80605 10993.5 69611 1.60 40 2400 3.74 84443 12564 71879 1.65 45 2700 3.46 87886 14134.5 73752 1.69 50 3000 3.23 91160 15705 75455 1.73 55 3300 3.03 94067 17275.5 76791 1.76 60 3600 2.83 95845 18846 76999 1.77 65 3900 2.71 99429 20416.5 79013 1.81 70 4200 2.59 102336 21987 80349 1.84 75 4500 2.48 104989 23557.5 81432 1.87 80 4800 2.38 107473 25128 82345 1.89 85 5100 2.29 109872 26698.5 83173 1.91 90 5400 2.21 112271 28269 84002 1.93 95 5700 2.13 114218 29839.5 84378 1.94 100 6000 2.06 116278 31410 84868 1.95 105 6300 2.00 118536 32980.5 85556 1.96 110 6600 1.94 120455 34551 85904 1.97 115 6900 1.88 122036 36121.5 85914 1.97 120 7200 1.84 124632 37692 86940 2.00 Average Outflow Storage Volume Storage Volume Catchment Drainage Area, ac: Release Rate, cfs: Storm Duration Time Rainfall Intensity Inflow Volume Modified FAA Method - 100-Year Storage Volume Calculations Inputs | Tributary Area Output | Detention Volume Return Period for Detention Control:Required Storage, cubic feet: Catchment 'C':Required Storage, ac-ft: H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College Drake\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports- Info\Hydrology\KSS 146_Rational_Routing.xls Page 1 of 2 10/5/2020 FYI: Per criteria, this should be C x Cf (1.25). or a max of 1.00. However, since this is a detention retrofit, not as big of a deal. I am okay proceeding with the C = 0.9 in this situation. Noted, thank you (i)(ii)(iii)(iv)(v)(vi)(vii)(viii)(ix)(x)(xi)(xii) Vault ID Total Required WQ Volume (cf) Flow, WQ (cfs) Chamber Type Chamber Unit Release Rate (cfs) Chamber Unit Volume (cf) Installed Chamber Unit Volume with Aggregate (cf) Minimum No. of Chambers Total Release Rate (cfs) Required Storage Volume by FAA Method (cf) Minimum No. of Chambers Storage Provided within the Chambers (cf) Total Installed System Volume (cf) A 14,649 13.40 MC-4500 0.026 106.5 162.6 91 2.366 5,137 49 9,691 14,796 (i) Calculated WQCV (Eq. 7-1 & 7-2) (ii) 1/2 of the 2-year developed flow rate for the basin being sized (use half of the 2-year intensity for the time of concentration used in the calc - i.e. for 5 min Tc, use 1.425) (iii) Per ADS, these equate to different chamber sizes they have available. (iv) Flow rate thru the bottom of the Isolator Row chamber which is equal to the area of the bottom of the chamber multiplied by the flow rate per unit area (.35 gpm/sf). (v) Volume within chamber only, not accounting for void spaces in surrounding aggregate. (vi) Volume includes chamber and void spaces (40%) in surrounding aggregate, per chamber unit. (vii) Number of chambers required to provide full WQCV within total installed system, including aggregate. (i) / (vi) (viii) Release rate per chamber times number of chambers. (iv) * (vii) (ix) FAA calc based on Flow, WQ and Total Release Rate. (x) Number of chambers required to provide required FAA storage volume stored within the chamber only (no aggregate storage). (ix) / (v) (xi) Volume provided in chambers only (no aggregate storage). This number must meet or exceed the required FAA storage volume. Greater of (vii) or (x) * (v) (xii) System volume includes total number of chambers, plus surrounding aggregate. This number must meet or exceed the required WQCV. Greater of (vi) or (x) * (vi) (xiii) Total number of Water Quality System Chambers to be installed. (i)(ii)(iii)(iv)(v)(vi)(vii)(viii)(ix)(x)(xi) Vault ID Chamber Type No. of Water Quality Chambers Provided Total No. of Chambers Provided No. of End Caps Provided Chamber Volume (cf) Installed Chamber Volume with Aggregate (cf) Installed End Cap Volume with Aggregate (cf) Water Quality Volume Provided (cf) Total Chamber Volume Provided (cf) Total End Cap Volume Provided (cf) Total Installed System Volume (cf) A MC-4500 91 463 46 106.5 162.6 115.3 14,796 75,283 5,303 80,586 (i) ADS chamber size provided in system. (ii) Number of WQ chambers provided. (ii) Number of chamber provided (including WQ). (iv) Number of end caps provided. (v) Volume within chamber only, not accounting for void spaces in surrounding aggregate. (vi) Volume includes chamber and void spaces (40%) in surrounding aggregate, per chamber unit. (vii) Volume includes end cap and void spaces (40%) in surrounding aggregate, per chamber unit. (viii) Total Volume provided in WQ chambers. (ii) * (vi) (ix) Total Volume provided in chambers, including WQ chambers. Excludes end caps. (iii) * (vi) (x) Total Volume provided in end caps. (iv) * (vi) (xi) System volume includes total number of chambers & end caps, excludes surrounding aggregate. (ix) + (x) See additional Stage Storage tabulation for total system volume including surrounding aggregate. WQ System Calculation Summary Detention System Summary H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College Drake\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports-Info\Hydrology\KSS 146_Rational_Routing.xls Page 2 of 3 10/7/2020 the FAA calc for stormtec calc has 3.6 cfs. These need to match. Suggest FAA calc is not correct. The total volume should be detention + water quality 86940 + 14649CF = 101,589 CF corrected this value in FAA calc modified table to include total vol- ume Project Name:King Soopers Store #146 Project No.: Calculated By:E. Mowinckel Checked By:P. Dalrymple Date:10/5/20 (sf)(ac) On-Site 378,401 8.69 Off-site 83,009 1.91 Total 461,410 10.59 On-Site 424,443 9.74 Off-site 34,651 0.80 Total 459,094 10.54 New Impervious Area 46,042 1.06 Modified Impervious Area 378,401 8.69 Required Minimum Impervious Area to be Treated 424,443 9.74 Total Impervious Area Treated 424,443 9.74 Portion of New and Modified Impervious Area 100%>75% Notes: 1) Refer to Impervious Area Exhibit, Appendix D Existing Impervious Area Proposed Impervious Area 75% On-Site Treatment by LID Requirement (without Pavers) KSS000018.02 LID SUMMARY TABLE H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College Drake\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports-Info\Hydrology\KSS 146_Rational_Routing.xls I am unclear if the project is providing the required water quality treatment area. Please do the following things: -Move this table to the report body in the water quality (WQ) discussion section. -For a redevelopment project, the off-property areas are not subject to WQ/LID requirements. Please remove the off-site (off-property) impervious area from this tabulation. - For clarification: All areas that are within your property (on-site) need to be in this tabulation, even if they "drain off-site". -It may help to add landscape areas to this tabulation. -Moved to the report body -revised calcs to only address on-site areas - per discussions with the City, on-site impervi- ous areas infeasible to be captured on-site are acceptable -table has been simplified and summarizes the impervious areas more clearly without needing to include pervious area RxPICKUP21 CO CO E EVT ECB GM E E E E TL TL E TL GM IR TL CO CO E E IR IR IR EVT ECB GM IR CO IR E E E E TL TL RI CO EM WM GM DYHDYHE IR GM ECB ECB DYH DYH ECB EME TL GM WM IR CO TL CO CO - - - - - - - - - - - - - - STAMP H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\Exhibits\KSS146_Impervious Areas.dwg - Erland Mowinckel - 10/5/2020Init.#Issue / DescriptionDate THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 Planning. Architecture. Engineering. O www.gallowayUS.com C 2016. Galloway & Company, Inc. All Rights Reserved PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate: Drawn By: Project No: Checked By: KSS000146 OF 1EXHIBIT FORMIDTOWN GARDENS MARKETPLACEKING SOOPERS MARKETPLACE #146S. COLLEGE AVE. & DRAKE RD.FORT COLLINS, COLORADOEKM PJD 10/07/2020 IMPERVIOUS AREA EXHIBIT 1SCALE: 1"=40' 0 20 40 This area should have WQ treatment provided or explain why it is not necessary Please draw a boundary around "new and modified" impervious areas on the property and report this are - this is the required water quality treatment area. This area should have WQ treatment provided or explain why not necessary Per discussions with the City, this area is infeasible to capture to the constraint of matching existing grades along the north edge of pavement. creating a low point here would crease unacceptable cross-slopes Per discussions with the City, this area is infeasible to capture to the constraint of matching existing grades along the north edge of pavement. creating a low point here would crease unacceptable cross-slopes. However, an inlet has been provided to capture a portion of this area and reduce the amount of runoff flowing offsite the boundary delineations have been updated per the comments regarding WQ & LID