HomeMy WebLinkAbout701 SANDPIPER PT - SPECIAL INSPECTIONS - 9/10/2021~ATLO K '"I~
HIGH LIFT
-i ' c:t11~Jor:y \Jarne
-· ' l
i
j
l-
.. \. f)f--~i icc1 t ,.)v h.J?i rne
~-·--· ---
-'.~,b:,;t(:; /\ti ~i rt➔SS --
PE:rry~ .t 1'! u :"•7 ber
I D: stLJ:l!dti. ve-~;,r;~ Lil
I
Cl:t v fu ~4 ;-i
/
70! <;,..,/,,,-,,er foi,,,;.. h,,-C./t,.,,; C:0
I r
8 JCJ03CJ7:2
1/"
P hone Nu m ber o/7fJ -l/J3 -1/!2 0 5'
-,
I
Inst a ll ation Da t e 8 -2'1-;l I
A-Side Lot #'s
-·
B -Side Lot #'s
I --1
1---____ __._ _____ ~ _____ ...__ _______ 1
I . I
i..._ ____________ _._ ____________ __. _____________ J
www.De mi lec.com CDEMLEC
H ATLOK'I HFO
HIGH LIFT DEMILEC
Heatlok' HFO High Lift is a two component, closed cell, spray applied, rigid polyurethane foam system. This product uses recycled plastic
materials, rapidly renewable soy oils, and the blowing agent has zero ozone depleting potential. Heatlok HFO High Lift complies with the
intent of the International Code Council's residential and commercial building codes and is commonly used as a thermal insulation, air
barrier, vapor retarder and water resistive barrier in above grade, below grade, interior and exterior applications.
ASTM D 1622
ASTM C 518
ASTM E 283
ASTM E 2178
ASTM E 96
ASTM D 2842
ASTM D 1621
ASTM D 1623
ASTM D 2126
voe Emissions
ASTM C 1338
ASTM D 2856
ASTM C 1029
ASTM E 84
AC 377 Appendix X
NFPA 286
ASTM D 1929
Cream Time
O - 1 seconds
Core Density 2.0 -2.4 lb/ft'
Aged Thermal Resistance 1" = 6.3 ft2h°F/BTU
3.5" = 26 ft'h°F/BTU
Air Leakage @ 75 Pa @ 1" < 0.02 L/sm2
Air Permeance @ 75 Pa @ 1" < 0.02 L/sm2
Water Vapor Permeance 1.56 perms Class Ill vapor barrier per IBC Section 202@ 1"
Class II vapor barrier @ s 1 perm 1.875ll
Water Absorption (volume) 0.87%
Compressive Strength 34.8 psi
Tensile Strength 101.3 psi
Dimensional Stability@ 158°F (70°C) 97% R.H. -3.7 (% volume change) (168 hours)
UL Environment (Greenguard Gold) Meets Criteria
Fungi Resistance No fungal growth
Closed Cell Content 91%
Standard specification for spray applied rigid cellular Type II Compliant polyurethane thermal insulation
Surface Burning Characteristics, 4 11 thick
Flame Spread Index
Smoke Developed
Ignition Barrier -Compliant with 2009, 2012 & 2015 IBC and IRC, and ICC-ES
AC-377 Appendix X, for use in attics and crawl spaces without a prescriptive
ignition barrier or intumescent coating.
Thermal Barrier -Compliant with the 2009, 2012 & 2015 IBC and IRC, as an
interior finish without a 15 minute thermal barrier when coated with DC-315 at 18
mils wet film thickness, 12 mils dry film thickness, or Blazelok"' TBX at 18 mils wet
film thickness, 12 mils dry film thickness.
Ignition Properties (spontaneous ignition temperature)
Gel Time Tack Free Time
2 seconds 3 - 4 seconds
32.0 -38.4 kg/m'
11' = 1.10 Km 2/W
3.5" = 4.57 Km'/W
89.25 ng/Pa•s•m2
47.63mm
240 kPa
698 kPa
Class I
10 -15
350 -400
Pass
Pass
766°F (408°C)
End of Rise
3 - 4 seconds
3315 E. Division Street, Arlington, TX 76011
Phone (817) 640-4900, Fax (817) 633-2000
lnfo@Demilec.com,www.Damilec.com
Heatlok HFO High Lift Technical Data Sheet
Last Revision 9-17-19
Page 1 of 2
HEATLOK
HIGH LIFT
PROPERTY A·PMDI ISOCYANATE
Color Brown
Viscosity@ 77°F (25°C) 180 -220 cps
Specific Gravity 1.24
Shelf Life of unopened drum properly stored 12 months
Storage Temperature 50 -100°F (10 -38°C)
Mixing Ratio (volume) 1:1
*See SDS for more information.
Initial Hose Heat Setpoint Temperature
Initial Processing Setpoint Pressure
Substrate & Ambient Temperature
Moisture Content of Substrate
105 -115°F
1200 -1400 psi
Summer > 50°F
Winter > 15°F
:519%
HEATLOK HFO HIGH LIFT RESIN
Blue
500 -800 cps
1.17 -1.21
6 months
59 -77°F (15 -25°c)
1:1
41-4s•c
8274 -9653 kPa
Summer > 1O°c
Winter > ·9°C
::;;19%
Moisture Content of Concrete Concrete must be cured, dry and free of dust and form release agents.
•Foam application temperatures and pressures can vary widely depending on temperature, humidity, elevation, substrate, equipment and
other factors. While processing, the applicator must continuously observe the characteristics of the sprayed foam and adjust processing
temperatures and pressures to maintain proper cell structure, adhesion, cohesion and general foam quality. It is the sole responsibility of the
applicator to process and apply Heatlok HFO High Lift within specification.
General Requirements: Equipment must be capable of delivering the proper ratio (1:1 by volume) of polymeric isocyanate (PMDI) and polyol
blend at adequate temperatures and spray pressures. Substrate must be at least 5 degrees above dew point, with best processing results
when ambient humidity is below 80%. Substrate must also be free of moisture (dew or frost), grease, oil, solvents and other materials that
would adversely affect adhesion of the polyurethane foam. Applicators should limit the application of this product to no more than a
thickness of 6.5" (165mm) per pass (after expansion) to avoid fire hazards (including spontaneous combustion) resulting from excessive heat
generation. If subsequent passes are needed, applicators should wait until the core temperature of the foam has dropped below 100°F to
allow any reaction heat to dissipate from the prior applications before attempting to reapply the product.
Ambient Temperature Maximum Pass Dual Pass (x" + x")
90°F c21°c> 6.5" 3.25" + 3.25"
>70°F c21°c>; <so°F c2,0 c> 4" 3.25" + 3.25"
>80°F (27°C) 3.25" 3.25" + 3.25"
Heatlok HFO High Lift must be separated from the interior of the building by an approved thermal barrier or an approved finish material
equivalent to a thermal barrier in accordance with applicable codes. Heatlok HFO High Lift must be sprayed at a minimum thickness of 1" per
pass. This product must not be used when the continuous service temperature of the substrate or foam is below -60°F (-51°C) or above
180°F (82°C). Heatlok HFO High Lift should not be used to cover flexible ductwork.
Disclaimer: The information herein is to assist customers in determining whether our products are suitable for their applications. We request
that customers inspect and test our products before use and satisfy themselves as to contents and suitability. Nothing herein shall constitute
a warranty, expressed or implied, including any warranty of merchantability or fitness, nor is protection from any law or patent inferred. All
patent rights are reserved. The foam product is combustible and must be protected in accordance with applicable codes. Protect from direct
flame and spark contact, around hot work for example. The exclusive remedy for all proven claims is replacement of our materials.
3315 E. Division Street, Arlington, TX 76011
Phone (817) 640-4900, Fax (817) 633-2000
lnfo@Demilec.com,www.Demilec.com
Heatlok HFO High Lift Technical Data Sheet
Last Revision 9-17-19
Page 2 of 2
3315 E. Division Street, Arlington, TX 76011
Phone (817) 640-4900, Fax (817) 633-2000
lnfo@Demilec.com,www.Demilec.com
Heatlok HFO High Lift Technical Data Sheet
Last Revision 9-17-19
Page 3 of 2