HomeMy WebLinkAbout2538 NANCY GRAY AVE - SPECIAL INSPECTIONS - 9/15/2021September 15 , 2021
Dominick Campana 3rdgenbuildersinc@qmail.com
Nico Campana ncampana@bellis imoinc.com
Observation Report I
Project: 2538 Nancy Gray, Fort Collins, Colorado
TDSE Project No.: 21-052
Plans/Details: Plans by TD Structural Engineering Inc. dated 6/23/2021
Observation Dates: 9/15/2021
Items Reviewed: st air installation, floor joists at mud room
Notes:
TD~~L
ENCifNE~~C
I understand the 16" I joists were used in lieu of the 9 ½" for the mudroom. This is an adequate
substitution.
Secondly, the wall at the wood stair has a 16" rim board with 2x stud blocking spanning across the floor
joint in the middle of a 2-story wall. I recommend strapping from studs above across the blocking at the
floor to the studs below, lapping a minimum of 16" on the studs, and spaced at 4' on center or closer.
Observations indicate the strapping is installed in accordance with recommendations and therefore the
wall framing at the stair is adequate as installed.
Please let me know if you have any questions.