Loading...
HomeMy WebLinkAbout2538 NANCY GRAY AVE - SPECIAL INSPECTIONS - 9/15/2021September 15 , 2021 Dominick Campana 3rdgenbuildersinc@qmail.com Nico Campana ncampana@bellis imoinc.com Observation Report I Project: 2538 Nancy Gray, Fort Collins, Colorado TDSE Project No.: 21-052 Plans/Details: Plans by TD Structural Engineering Inc. dated 6/23/2021 Observation Dates: 9/15/2021 Items Reviewed: st air installation, floor joists at mud room Notes: TD~~L ENCifNE~~C I understand the 16" I joists were used in lieu of the 9 ½" for the mudroom. This is an adequate substitution. Secondly, the wall at the wood stair has a 16" rim board with 2x stud blocking spanning across the floor joint in the middle of a 2-story wall. I recommend strapping from studs above across the blocking at the floor to the studs below, lapping a minimum of 16" on the studs, and spaced at 4' on center or closer. Observations indicate the strapping is installed in accordance with recommendations and therefore the wall framing at the stair is adequate as installed. Please let me know if you have any questions. TD Structural Engineering, Inc. I 2909 Oxford Ct., Fort Collins, CO 80525 I 970.372.1140 I www.tdstructural.com