HomeMy WebLinkAbout719 COLORADO ST - SPECIAL INSPECTIONS - 8/30/2021 F E L T "A 00 Uf
ARCHITECTURE ENGINEERING FORENSICS
August 30,2021
Studio Shed
1500 Cherry Street
Louisville, CO 80027
Attn: Ben Seaman
Re: Mika
esidence
719 Colorado Street Fort Collins,CO
As requested, the following observation was performed at the referenced address on the date
indicated below. As per our observation, it is our opinion that the observed portions of the
foundation system were found to be in general conformance with the foundation plan for the subject
site. Observations were conducted on a periodic,on-call basis.
Date: Observation:
August 24,2021 Slab Inspection
An electrode is located within and near the bottom of the turndown that is in direct contact with
the earth consisting of at least(20ft)of one or more bare or zinc galvanized or other electrically
conductive steel reinforcing bars or rods of not less than(1/2')in diameter. Reinforcing bars are
bonded together by steel tie wires or other effective means and stubbed out for conductor
bonding.
Sincerely,
Felten Group, Inc.
42501
08/30/2021
9025 EAST MINERAL CIRCLE SuITE 200 • CENTENNIAL,CO 80112 • PxoNE: 720-638.6355 • FAX: 602-867.2503