HomeMy WebLinkAbout719 COLORADO ST - SPECIAL INSPECTIONS - 8/30/2021 F E L T "A 00 Uf ARCHITECTURE ENGINEERING FORENSICS August 30,2021 Studio Shed 1500 Cherry Street Louisville, CO 80027 Attn: Ben Seaman Re: Mika esidence 719 Colorado Street Fort Collins,CO As requested, the following observation was performed at the referenced address on the date indicated below. As per our observation, it is our opinion that the observed portions of the foundation system were found to be in general conformance with the foundation plan for the subject site. Observations were conducted on a periodic,on-call basis. Date: Observation: August 24,2021 Slab Inspection An electrode is located within and near the bottom of the turndown that is in direct contact with the earth consisting of at least(20ft)of one or more bare or zinc galvanized or other electrically conductive steel reinforcing bars or rods of not less than(1/2')in diameter. Reinforcing bars are bonded together by steel tie wires or other effective means and stubbed out for conductor bonding. Sincerely, Felten Group, Inc. 42501 08/30/2021 9025 EAST MINERAL CIRCLE SuITE 200 • CENTENNIAL,CO 80112 • PxoNE: 720-638.6355 • FAX: 602-867.2503