HomeMy WebLinkAbout924 BREAKWATER DR - PERMITS - 3/26/2021Owner:HAY PHYLLIS A REVOCABLE LIVING TRUST
924 BREAKWATER DR
FORT COLLINS, CO 80525
Phone: 847-508-6448
Zoning:Front setback:Rear setback:42'Right setback:Left setback:16'
Minor Amend #:Plat File #:ZBA Case #:
Zoning district:RL - LOW DENSITY RESIDENTIAL DISTRICT
Legal:Subdivision/PUD:Filing #:Lot #:Block #:
Code:Res sq ft:638 Com sq ft:Ind sq ft:Basement sq ft:
# of stories:Occ Group:Const Type:
Fire Sprklr:Stock plan #:Stock plan options:
Contractor:ROCKY MOUNTAIN FENCE & DECKS
614 W. 29th St.
Loveland, CO 80537
License #:D-837
Phone: 970-402-1000
Supervisor cert #:
Subcontractor(s)Phone License Number
Work Description:
Construction of a 638 sq. ft. deck. Job contact: Travis Kerns
SCHEDULE INSPECTIONS: ** via Text Message: 888-406-6394 ** By Phone: 970-221-6769
** Online Portal: fcgov.com/CitizenAccess ** Online Portal via Mobile Device: fcgov.com/CitizenAccess/mobile
Possible Inspections Required: 101 100 203 303
TOTAL FEES PAID AS OF 03/26/21: $1,443.56 Payment method:Credit Card 4941
** Fee Detail Displayed on Next Page
As a condition for the issuance of a permit, I hereby declare that I am the owneror owner's agent, authorized to perform the proposed workonthe property describedherein.
I agree to comply with all the requirements contained herein, and City ordinances, and State lawsassociated with suchwork. I understand that suchpermit may be
revoked in the event that issuance was basedonincorrect information. This permit shall becomenull and void if the workauthorized by suchpermit is not commenced,
suspended, abandoned or not inspected within 180 daysfromthe date of such permit.
Community Development & Neighborhood Services
281 N. College Ave Fort Collins, CO 80522
970.221.6760 970.224.6134 - fax
Building Permit #:B2100684
Issued Full:03/26/2021
Permit Type:Deck
Site Address: 924 BREAKWATERDR
Job Valuation:$34,623.78 Category:Residential Remodel
Signature:Print Name:Date:
Form Revised Oct 2010
Transactions
Method Check Number Date Paid Amount Paid Comments
Credit Card CK # 4941 02/01/2021 $1,443.56
Receipt issued:03/26/2021 Total Paid to Date:
$1,443.56
Fee Description Account Code Fee Amount Amount Paid Date Paid Amount Due
Building Permit Fee Without
Subs
1000.422010 $387.00 $387.00 02/01/2021 $0.00
City Sales/Use Tax 251.122030 $666.51 $666.51 02/01/2021 $0.00
County Sales/Use Tax 100.217030 $138.50 $138.50 02/01/2021 $0.00
Plan Check Fee 1000.444010 $251.55 $251.55 02/01/2021 $0.00
TOTAL FEES:$1,443.56 $1,443.56 $0.00
TOTAL BALANCE DUE AS OF 03/26/2021:$0.00
Community Development & Neighborhood Services
281 N. College Ave Fort Collins, CO 80522
970.221.6760 970.224.6134 - fax
Building Permit #:B2100684
Issued Full:03/26/2021
Permit Type:Deck
Site Address: 924 BREAKWATERDR
Job Valuation:$34,623.78 Category:Residential Remodel
Fee Amounts are valid for date of this document only. Fees subject to change without notice.
Form Revised Oct 2010
City of ktColl� COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES
281 N. College Ave. • Fort Collins, CO 80524 • Phone: 970.416.2740 • www.fcgov.com/building
BUILDING PERMIT APPLICATION
FOR OFFICE USE
APPLICATION NUMBER: APPLICATION DATE:
Job Site Address 924 Breakwater Dr.
PROPERTY OWNER INFO: (All owner information is required -NOT optional)
Last Name Hay First Name Howard Middle ----------
Unit#
Street Address 924 Break Water Dr City Fort Collins state Co Zip 80525
Phone# 84 7-508-6448 Email
Name of Business (COMMERCIAL USE ONLY)
CONTRACTOR INFO: Company Name Rocky Mountain Fence & Decks
License Holder Name Travis Kerns uc # D-837 CERT#
LEGAL INFO:
---
Subdivision/PUD The Landing Filing# 3 Lot# 15 Block# ---�---__ Lot Sq Ft ___ _
CONSTRUCTON INFO: Total Building Sq Ft (NOT including basement) Total Garage Sq. Ft. ----------�
Residential Sq Ft Commercial Sq Ft # of Stories Bldg Ht # of Dwelling Units-------
1st Floor Sq Ft 2nd Floor Sq Ft 3rd Floor Sq Ft Unfinished Basement Sq Ft -------
Finished Basement Sq Ft # of Bedrooms -----
% Baths � Baths
ENERGY INFORMATION: (CHECK ONE)
ComCheck D UA {ResCheck) D
Air Conditioning? YES D
# Fireplaces
SPA(Simulated Performance DAlternative)
NO D
# of Full Baths
PrescriptiveD
City of Fort Collins Approved Stock Plan# SPO List Option #s
ER l{Energy Rating Index) D
----------------------
UTILITIES INFO: Gas l!!!!I Electric O Electric Temp. Pedestal Yes
Electric Main Breaker Size (Resid ential Only): 150 amp or less D 200 Amp
ZONING INFO: (COMMERCIAL USE ONLY)
Proposed Use: (i.e. medical, office, bank, retail, etc.)
For Commercial remodels and tenant finishes, please answer the following questions:
Is the remodel/tenant finishes for an existing or new tenant? (Please check one)
Existing TenantD New Tenant D
If for a new tenant, is this the first tenant to occupy this space?
D No D
D Other D
Yes D No D If not for the initial tenant for this unit, what was the previous use of this tenant space?
Are there any exterior building changes (including mechanical) associated with the work?
If yes, please describe:
Yes D No D
B2001456 1/27/2021
Value of Construction (materials and labor}: $34,623.78 __;_ ______________________ _
Descrip tion of work: Rebuilding the existing deck on existing caissons { See engineered drawings }
JOBSITE SUPERVISOR CONTACT INFO: Name Travis kerns--------------Phone 970-402-1000
Mechanical N/ASUBCONTRACTOR INFO: Electrical N/A------------------------
Plumbing N/ A Framing
Solar
YES Roofing N/A--------------------
Fire p I ace N/ A N/A 0th er----------
ASBESTOS STATEMENT DISCLOSURE: In accordance with the State of Colorado Senate Bi/113-152, property owners, applying for a
remodel permit, shall indicate their awareness about their property having been inspected for Asbestos Containing Materials (ACM's).
0 I do not know if an asbestos inspection has been conducted on this property.
D An asbestos inspection has been conducted on this property on or about (enter date)
D An asbestos inspection has not been conducted on this property.
Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to
comply with all requirements contained herein and City of Fort Collins ordinances and state laws regulating building construction.
Applicant Signature �
Phone# 970-402-1000
L-t---Type or Print Name Travis Kerns
Email rmdfence@comcast.net
THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE
···: -Cityof Residenti_al Deck -Guide �tColl�
Homeowner Affidavit or Authorized Contractor License:
7/27/2020 A B, C, C2, D, D2, MM (MM does not include 2 story decks)
A permit is required for any of the following conditions: Decks that are more than 30" above grade,
attached to the house; or serve the front exi or.
Option #1: The Deck is Engineered
Plans are provided and stamped by a Colorado Licensed Structural Engineer. {check options on page 4 )
Option #2: I am designing to code { current adopted International Residential Code) D
I have used the code link below to design my plans per code to the best of my ability. {Fill out page 4)
Plans that do not meet code, will need to be re-de,signed / re-submitted or engineered.
Will the deck be attached to the house or self-supported?
What is the area {square feet) of the proposed deck?
Code Access (2(1-18 IRC & local amendments)
•https://codes.iccsafe.org/content/lRC2018
Chapter 5 -Section 507 Exterior Decks
• · https://w ww.fcgov.com/building/ codes.php
Engineered and stamped structural plans or letter is
required for the following conditions:
1 . Beam supported by hangers
2. Ledger attached to a cantilever/overhang on the
existing house such as a bay window
3.Kits or pre-manufactured designs
4.Designs other than those presented in code.
5.Decks attached to brick, masonry or veneer.
6.Decks supporting a hot tub/pool.
7.Multi-story stacked decks
8.Steel decks that do not conform to section R505,
including the use of steel beams, or steel decks for
properties located West of Overland Trail (> 140
mph wind region)
Joists cannot
attach to a
cantilever on
Beams cannot
attach to ledgers,
only joists can
Beam
1.Y+$
Submittal Checklist
�rmit Application
�uilder: Contractor or Homeowner
Affidavit
�ck info filled out (page 4)
@site Plan (2 copies)
[]1i'oor Plan (2 copies)
[]s'fde view/ elevation (2 copies)
[:f'connection details (2 copies)
�t least 1 before photo showing
where the deck will be located.
�yment ( check, cash, credit
card)
·Re uired Ins ections
l.Setback and Footing (Pier Hole}
2.Foundation (post connect ions)
3.Rough Frame & Rough Electric
4.Final Inspecti on
City of ktColli� Residential Deck Guide
Check one of the following: Step E: Provide deck design info:
D I am submitting professionally engineered, stamped deck plans. I have confirmed that all of the following
required fields are provided on the engineered plans. Any fields not provided on the plans have been filled
out in the form fields below as needed (ie. deck height/ materials). 0 I am designing to code. All fields below must be filled out and noted on plans.
https :// codes.iccsafe .erg/content /IRC2018 ( chapter 5) https://www.fcgov.com/building/ codes.php
Topic Code Section
1 I Decking
Material and orientation to joists Table R507.7
2 I Joists
Species and size of joists Table 507.6
Span/length of joists Table & Figure R507.6
Do the joists cantilever? If so, how far? Figure & Table R507.6
(right column in table)
Spacing of joists (measured center to Table R507.6
center)
3 [ Beams
Wood Species and size of beam Table R507.5
Span/ length of beam between posts Table R507.5
Does the beam cantilever? How far? Text Section R507 .5
4 l Joists to beam connections (See Steo D}
Draw connection detail with fasteners Fiaures R507.5.1-R507.5.2
s I Posts
What is the height of the deck Table R507.4
What is the size of the post Table R507.4
6 I Beam to post connections (See Steo D l
Draw connection detail with fasteners R507.5. l & R507.5. l (2)
1 I Pier/Footina size (See Steps B & C)
Required 30" min deep below grade Local Frost Depth
Type of footing/piers Text R507.3 & Figure R507.3
Size of footing/piers Table R507.3. l
Use 40psf snow load
Use 1,500 psf Soil Bearing
s I Post to pier/footing connections (See Step Cl
Show connection details on plans R507.4. 1 & R507 .3
9 I Ledger /Band joist Connection
How will the joists connect to the Section R507.8 -507.9.2 &
house? Table R507.2.3
Fill in required items
·:?� ,c..,k_r.
4w -�"'l� f.�
h" ;;;. ' PL.-.. -, " \ -
·4w �a•-"'· -?�
�6,; �, � f {t-,
·711G Gvv:., u..:..,.
�g::.;;. �c.,-'",, ..-,,
0� kwk:. \ ... :_A'
Show on Plans
.f ff
'?a;-
$-i -
��
r::_ ..... I
Show on Plans
e-�
p /, ..
PluAJ.
f�
'i>l'4. -
30 inches min. Deep
Show on plans
,' 7w �e,,� I�
Show on plans
Show on plans
Residential Deck Guide
Show location of the new structure in relation to the house
§' Provide measurements from deck to property lines0 8.5xl l or 8.5xl 4 page size
Newer homes may have an existing site plan available
so·--0• PROPERTY LINE
....
HOUSE
�---<GARAGE
through public records, which can be used to create the NEW site plan.
http://citydocs.fcgov.com/ NORTH
Step B: Draw a floor plan as if looking down from above.
Tributary area
for each pier.
Table 507.3.1
Ill QI ·.::;QI Q.
,:: ·.::;RI 11 VI
I QI•
' Step C: Draw an Elevation view (Side View) I
BEAM PER CHART
5 REDWOOD OR TREAlED POST. ONLY TREATED WOOD CAN BE CAST INTO CONCRETE
BcoNCRETE PIER
METAL CONNECTORS SEE DETAILS
60'-0" PROPeRT'( UNE
424MA1NSl SAMPLE SITE PLAN SCALE 1"=20'
Handrail
Cantilever
3'--0" min .. ...
OPENING MUST NOT MJ...OW 4" SPHERE TO PMS THROUGH
LESS THAN 6"
• 4" min -7 %" max
•<4" openings
Treads:
• 10" min.