HomeMy WebLinkAbout414 N LOOMIS AVE - SPECIAL INSPECTIONS - 5/24/2021CES Consultants, LLC
May 13 , 2021
Threseaj'irth
414 N Loomis Street
Ft. Collins, CO 805 2 1
Re: Structural Design of New Upsta irs Bathroom Window Header for the
remodel of the Single-Family Residence located at 414 N. Loomis Avenue, Ft.
Collins, Colorado 80521 (Ft. Collins Building Permit #B2101421)
D ear Thresea:
Per your request, CES Consultants, LLC (CES) has prepared the structural design of the
new exterior wall window header in the upstairs bathroom for the remode l of th e
res id e n ce located at 414 N. Loomis A venue, Fo rt Collins, Colorado. The new header will
s upport loads from the exi st ing roof and is designed to support the C ity of Ft. Co llin s
Design Roof Live Load of 3 0 psf a nd a Roof Dead Load of 15 psf.
T he ne w heade r for the upstairs bathroom window, which will be less than 3'-6" wide,
will need to be a 2-ply 2x8 h eader w ith o ne (I) 2x6 trimmer s tud and (1) 2x6 king stud o n
each s ide of the windo w opening.
T his lett er was prepared fo r the exc lu s iv e use of our client and is n ot intended for a ny
o ther purpose. Our conclusions are based on th e information made avai lable to us at thi s
time. S ho uld additional info rm atio n become availabl e , we r eserve t he right to determine
th e impact , if a ny, of the new information on our opinions and conclus ion s; and to revi s e
o ur opinions a nd conclusions if necessary and warrante d by the di scovery of add ition a l
information.
If you have any questions or comments concerning this matter, pl ease feel free to contact
me at (970) 373-4480 or k urt@ cescons ul tants ll c .com
Sincerely,
CES CONSU LTANTS, LLC
Kurt Rollin , P .E.
Principal
721 4th Street, Suite I • Ft. Lupton, CO 80621 • Phone : (970) 373-4480