HomeMy WebLinkAbout359 LINDEN ST - SPECIAL INSPECTIONS - 6/4/2021~ ENGINE!=f=!.ING S....,ffA FXPr?E-.HS June 4, 2021 Prepared For: Denver Pergo la Systems 5273 Adahi Rd Indian Hills, CO Regarding: G&B/ f~,~·,+ ~ e, ;;l. \ 6 ;:).. ' ). \ 359 LINDEN ST. FORT COLLINS, CO 80524 FORT COLLINS, CO EX Project #21 -37207 -Order #659 1 Attention: Building Department Official This office has reviewed the design and installation of the Struxure Mechanically opening Pergola at the above address as detailed in EX drawing set #21-37207. Additionally , due to some unforeseen site-specific conditions, the installation of these posts into the footings detailed may be adjusted as noted herein. This letter is applicable for any or all of the posts included in this plan. At many of the columns included in t his installation, suitable ground was not found for caisson installation as detailed in the above referenced plan. As such, this office is approving the use of helical piles to be installed and used in place of the caisson piles designed. These helical piles are to be separately designed and certified by a licensed eng ineer, and must be designed to support the forces and reactions found in the corresponding calculation packages, rounded up to the nearest 25 lb. These reactions are to be as follows: Tension = 200 lb ; Compression = 2200 lb; shear= 150 lb, and moment= 27,900 lb-in(= 2325 lb-ft). T hese designed piles are also to be encased in 5000 psi non-shrink grout min (or as specified per separate engineering) Once installed, these helical piles may be connected to the posts via a steel plate, ( 4) thru bolts, and a standard post base-cap. The steel plate is to be 3/8" galvanized steel (m in) and is to be welded to the steel pile cap using a 1/8" min perimeter fillet weld. This plate is to have (4) 3/8" SS thru bolts with double-nuts into the post cap as detailed below. The post cap is to be attached to the post using a (6) #14 tek screws (min). Posts and plates installed in this fashion may not be directly centered over the helical pile, but must remain within a I" eccentricity from the edge of the post to the pile casing. Except as expressly provided herein, no additional certifications or affirmations are intended. Final approval shall be at the discretion of the governing authority having jurisdiction as inspection of work completed under permit has been performed by others. Unless otherwise noted herein, all work and in stallation shall follow the direction and details provided in the sealed drawing EX #21-37207, as well as the minimum requirements of the International B uild ing Code (2018) and all other referenced codes and standards. Thank you for your attention to this matter. Respectfu lly , Frank Bennardo PE ENGINEERING EXPRESS® PE#0053085 160 SW 12TH AVENUE SUITE 106, DEERFIE L D BEACH, F LORIDA 33442 (954) 354-0660 I (866) 396 -9999 T EAM@ENGI NEERING EX PRESS . COM ENGINEERINGEXPRESS. '.:OM June 4, 2021 Prepared For: Denver Pergola Systems 5273 Adahi Rd I ndian Hills, CO Regarding: Attention: G&BJ 359 LINDEN ST. FORT COLLINS, CO 80524 FORT COLL INS , CO EX Project #21-37207 -Order #6591 Building Department Official This office has reviewed the design and installation of the Struxure Mechanically opening Pergola at the above address as detailed in EX drawing set #21-37207. Additionally, due to some unforeseen site-specific conditions, the installation of these posts into the footings detailed may be adjusted as noted herein. At the corner column shown in the photo, the retaining wall , -m·---,----+ noted prevented the installation of a full , tapered caisson as detailed ""-, __________ _ in the original structural plans. As such, this office has reviewed ~1 the forces and reactions at this post and determined that a surface-.. ,. mount attachment is sufficient for installation at the noted post. 1 At this post, use ( 4) 1/2" Power-Stud+ SD4 & SD6 anchors -----------I into the 3000 PSI Concrete slab. Maintain 3" concrete edge distance and 3 3/4" Anchor embedment. A typical detail has been provided for reference. Except as expressly provided herein, no additional certifications or affirmations are intended. Final approval shall be at the discretion of the governing authority having jurisdiction as inspection of work completed under permit has been performed by others. Unless otherwise noted herein, all work and installation shall follow the direction and details provided in the sealed drawing EX #21-37207, as well as the minimum requirements of the International Building Code (2018) and all other referenced codes and standards. Thank you for your attention to this matter. Respectfully, 1 1 :15:05 -04'00' FUNCTIONAL POST _BRA~KET TO FOOTER CONNECTION 6'x6" 160 SW 12TH AV E NU E SUITE 106, DEER FIE LD BEACH, FL O RID A 33442 (954) 354-0660 I (866) 396-9999 TEAM@EN G IN E E R ING EXPRESS. CO M ENGIN E ERIN G EXP RE S S. C OM