HomeMy WebLinkAbout2026 BEAR MOUNTAIN DR - 115 - SPECIAL INSPECTIONS - 4/20/20212133 S. Timberline Rd. – Suite 110
Fort Collins, CO 80525
ditescoservices.com
Delivery via e-mail to:
keith.meyer@ditescoservices.com
April 15, 2021
Mr. Keith Meyer, P.E.
Omni Cum Deo
2133 S. Timberline Rd STE 110
Fort Collins, CO 80525
RE: Bolt Inspection 2-8-2021 (Outrun Parkour)
Dear Keith:
The following inspection was performed on February 8, 2021:
Location/Project: Lofts at Timberline, 2021, 2027 and 2033 S Timberline Rd (parcels #8719144006, 8719144007,
8719144004)
Inspector: Kelsey Petersen
Inspection Type: Visual, High Strength Bolt (AISC Spec. for Structural Joints Using ASTM A325 or A490 Bolts,
Sect. 8,9), Welding per AWS D1.1
Observations: Structural connections at beam-to-beam and beam-to-column locations at Outrun Parkour
mezzanine. Inspection was at 10% frequency to hand tight condition per ASTM and Project Specifications. Bolts
observed to not be tightened to hand tight condition were tightened before completion of observation. 100% of
inspected bolts were in acceptable condition prior to completion of observation. Welds were inspected and
compliant with Plan Sheet S4.1, Details 3 and 5.
PEMB Plans by:
Outrun Parkour – RA Architects, Job # RRE20434, drawn on 12/7/2020
PEMB Steel supplied by: Hueber Industries
At the time of our observation, the items observed met the quality standards listed above: Yes
Discrepancies were observed, see attached discrepancy list: No
Please let me know if you have any questions regarding this monthly progress report or the attached invoice. I can
be reached by phone at 970.820.0175 or email bill.renz@ditescoservices.com.
Sincerely,
Bill Renz, P.E.