HomeMy WebLinkAbout2938 CONQUEST ST - SPECIAL INSPECTIONS - 5/25/2021May 25, 2021 Adam Hess Hartford Homes, LLC 4801 Goodman Street Timnath, Colorado 80547 Subject: Mr; Hess., Framing Clarifications Letter 29.~8 Conquest Street Lot 12, Block 16, Mosaic Subdivision Timnath, Colorado CTLIT Project Number: FC07735.151 It is our understanding that the a$-b1Jilt framing of the above structure varied from the design drawings provided by CTL Thompson (project number FC07735.151, dated 08/08/2020). Studs below the windows in the stair opening were framed using HF 2x6., wh.ereas .the plans specify 1 ¾''x5 ½'' LSL studs at the stairwell. Additionally, a Simpson HU hangerwas·installed where an HUG hanger was specified ln the "Roof Framing Plan." The flange that should be concealed has been bent back and end-grain nailed into the carrying member. Per your request, personnel from our office have reviewed the framing changes. The full height LSL studs at t.he stairwell are required for out-of-plane wind loading, but only apply to the full height studs and king studs. The HF 2x6 studs that have been installed as trimmer studs below the windows· and are not full height. Therefore, the installed studs are acceptable by design and no changes to the frami11g are required. 400 North Link Lane I Fort Collins, Colorado 80524 Telephone: 970-206-9455 Fax: 970-206-9441 At this time, Simpson Specifications C<!n not be found allowing for the bending of a flange on a hanger. Due to this, the bent hanger is not an acceptable replacement for the specified HUG hanger. (2) 2X4 min studs shall be installed below the beam at the stairwell in order to provide solid bearing support. The studs are supported below by the W14x30 steel beam requiring no further framing addition to support the new stud pack. Figure 3: New Stud Locatiol\ Thank you for selecting CTLITHOMP$ON for your engineering needs .. When we can be of addition.al service, please contact the unden,igned. Very truly yours, CTL!THOMPSON, INC. bevin Hougard May 25 202.1 S:.101\.M Devin Hougard, P.E. Project Engineer Hartford Homes 2938 Conquest-Street CTL I T PROJECT NO. FC07735. 151 2 a5-1d,t . g2,0 • P Lafayette LLC .. fi. A LJniv0.01 FprokPtodpc0 Coraprrny May 24,2021 To Whom It May Concern: Please note the following regarding roof truss CO1 G provided to Hartford Homes by UFP Lafayette,LLC for the home under construction at 2938 Conquest Street,Fort Collins,Colorado. Truss COIG was designed as a structural gable.Tt was designed to bear on 3-1/2 inch of bearing width at each end and was not designed with interior or continuous bearing. If you have any questions or if we may assist you further in this matter,please feel free to contact us. Sincerely, Joseph L.Neilson P.E. 7402;: ;'�38iTB&C ,t?.,,t. &?hl;: # 43S4i^t_A!E9Ad,L°4,7ti&'b�,'�Y'r�„'g Clr$Yiy itwt T« SFSh R�-T7Glttt '.bx Y$ , €5, '? R sr- t42CY1 P1 9 430 47 st rzia a4,r -ifii. [4 :teaat 4.244 •MAI fit' .� -T.i r 12 .. 1 : .¢3 .. `•-art it 1g • N iI. *# ' . 1201 E.South Boulder Road Lafayette,CO 80026-2029 303.666.6800 phone 303.666.512: 05/24/2021 UFP Lafayette, LLC A TJnNt1ri{r1'_:t?a,tfmt PrpduttSCqmpn:ny May 24, 2021 To Whom It May Concern: Please note the following regarding roof tmss COl G provided to Hartford Homes by UFP Lafayette, LLC for the home under constrnction at 2938 Conquest Street, Fort Collins, Colorado. Truss CO I G was designed as a structural gable. It was designed to bear on 3-1 /2 inch of bearing width at each end and was not designed with interior or continuous hearing. lf you have any questions or if we may assist you further in this matter, please feel free to contact us. 7~. t91G) J~"f~~· ':"Sj'.:i~~ ;$-):A, .'5':1~12.' . 1J'..i¾· i'-£:Jf1:.? Sincerely, Joseph L. Neilson P.E. 1201 E. South Boulder Road Lafayette, CO 80026-2029 303.666.6800 phone 303.666.512: 05i24/2021