HomeMy WebLinkAbout2126 LAMBIC ST - PERMITS - 3/4/2021 (3)Owner:WAGNER CHRISTOPHER L/MELISSA K
2126 LAMBIC ST
FORT COLLINS,CO 80524-3961 Phone:970-413-0262
Zoning:Front setback:Rear setback:18'11"Right setback:Left setback:
Minor Amend #:Plat File #:ZBA Case #:
Zoning district:LMN -LOW DENSITY MIXED-USE NEIGHBORHOOD DISTRICT
Legal:Subdivision/PUD:Filing #:Lot #:11 Block #:3
Code:Res sq ft:0 Com sq ft:Ind sq ft:Basement sq ft:
#of stories:Occ Group:Const Type:
Fire Sprklr:Stock plan #:Stock plan options:
Contractor:SUNDECK DESIGNS
305 N SUNSET ST
FORT COLLINS,CO 80521
License #:D2-117
Phone:970-690-9437
Supervisor cert #:2974-D2
Subcontractor(s)Phone License Number
Work Description:Construction of a 252 sq.ft.deck with stainless cable railing at rear of house.John Bridgham 970-690-9437.
SCHEDULE INSPECTIONS:**via Text Message:888-406-6394 **By Phone:970-221-6769
**Online Portal:fcgov.com/CitizenAccess **Online Portal via Mobile Device:fcgov.com/CitizenAccess/mobile
Possible Inspections Required:101 100 203 303
TOTAL FEES PAID AS OF 03/04/21:$959.07 Payment method:Credit Card 4807
**Fee Detail Displayed on Next Page
As a condition for the issuance of a permit,I hereby declare that I am the owner or owner's agent,authorized to perform the proposed work on the property described herein.
I agree to comply with all the requirements contained herein,and City ordinances,and State laws associated with such work.I understand that such permit may be
revoked in the event that issuance was based on incorrect information.This permit shall become null and void if the work authorized by such permit is not commenced,
suspended,abandoned or not inspected within 180 days from the date of such permit.
Community Development &Neighborhood Services
281 N.College Ave Fort Collins,CO 80522
970.221.6760 970.224.6134 -fax
Building Permit #:B2101012
Issued Full:03/04/2021
Permit Type:Deck
Site Address:2126 LAMBIC ST
Job Valuation:$22,000.00 Category:Residential Remodel
Signature:Print Name:Date:
Form Revised Oct 2010
Transactions
Method Check Number Date Paid Amount Paid Comments
Credit Card CK #4807 02/16/2021 $959.07
Receipt issued:03/04/2021 Total Paid to Date:$959.07
Fee Description Account Code Fee Amount Amount Paid Date Paid Amount Due
Building Permit Fee Without
Subs
1000.422010 $271.25 $271.25 02/16/2021 $0.00
City Sales/Use Tax 251.122030 $423.50 $423.50 02/16/2021 $0.00
County Sales/Use Tax 100.217030 $88.00 $88.00 02/16/2021 $0.00
Plan Check Fee 1000.444010 $176.32 $176.32 02/16/2021 $0.00
TOTAL FEES:$959.07 $959.07 $0.00
TOTAL BALANCE DUE AS OF 03/04/2021:$0.00
Community Development &Neighborhood Services
281 N.College Ave Fort Collins,CO 80522
970.221.6760 970.224.6134 -fax
Building Permit #:B2101012
Issued Full:03/04/2021
Permit Type:Deck
Site Address:2126 LAMBIC ST
Job Valuation:$22,000.00 Category:Residential Remodel
Fee Amounts are valid for date of this document only.Fees subject to change without notice.
Form Revised Oct 2010
FSiyfboltins coMMUNtry DEVELoPMENT & NEtGHBoRHooD sERVtcEs
/' - \_ t- 281 N. College Ave. . Fort Coltins, CO 80524 . Phone: 97O.4t6.274O . !51t:y_v-y,i-r:l-g.tv:Xgt.Ill.irtldijjij
BUILDING PERMIT APPLICATION
FCR OFFICE lJSE
,TION NUMBER:APPLICATION DATE:
Job site Address 2126 Lambic St. Fort Collins, CO 80524
PRoPERTY owNER tNid: iniiownei inioimition is requireO f Nof opiionari
Unit# NA
Phone * 974-413'0262 Email wagnermk@comcast.net
Name of Business (coMMERctAL UsE oNLYI
coNTMCToR lNFo: Company Name Sundeck Designs lnc.
License Holder Name John Bridgham Lrc # D2'117 cew *
LEGAT INFO:
subdivision/pun _Timb-eryilg _,_,-_Filing* 2:n! _Lot# 1_1-___,_elock* 3 _ Lotsqrt 52_!9
CONSTRUCTON INFO: Total Building Sq Ft {Nor including basement} ?5? I Garage Sq. Ft.
Residential Sq Ft______ __ __ _ _Commercial Sq Ft -__ _ ____# of Stories ,. _ Bldg Ht _____-_____f of Dwelling Units _ _ --,
1st FloorSq Ft ___ _ _ _ ___2nd FloorSq 3rd Floor Sq Ft _ __ ____ _Unfinished Basement Sq Ft
Finished Basement Sq Ft # of Bedrooms # of Full Baths
% Baths % Baths # Fireplaces
ENERGY INFORMATION: (cHEcK oNE)
comcheck EI uA (Rescheck) fl senff11r1';i;iPerrormance n prescriptivefl ERt(Fnerey Ratins tndex) n
Air Conditioning? YES tr NO V
City of Fort Collins Approved Stock Plan # SPO List Option
UTILITIES INFO: Gas tr Electric n Electric Temp. Pedestal Yes n No V
Electric Main Breaker Size (Residential Only): 150 amp or less n 200 Amp El Other n
ZoNlNc INFO: ICOMMERCIAL USE oNtYl
Proposed Use: (r.e. medicol, office, bank, retoil, etc.)
For Commercial remodels and tenant finishes. please answer the following questions:
ls the rernodel/tenant finishes for an existing or new tenant? (Please check one)
Existing Tenantfl New TenantE
lf for a new tenant, is this the first tenant to occupy this space?
Yes n No n lf not for the initial tenant for this unit, what was the previous use of this tenant space?
Are there any exterior building changes {including mechanical) associated with the work? Yes E No tr
lf yes, please describe:
Value of Construction {materials and laborl: 522,044
Description of Work: construct new ground level composite surfaced 252 sq. ft. deck with stainless
cable railing at rear of house
JOBSITE SUPERVISOR CONTACT INFO: Name
SUBCONTRACIOR INFO: rlectrical NA
John Bridgham Phone 970-690-9437
Mechanical NA
Plumbing NA Framing N4 Roofing NA
Fireplace NA Solar NA other NA
ASBESTOS STATEMENT DISCLOSURE: ln accorddnce with the State of Colorado Senofe Bitl 13-752, property owners, applying for a
remodel permit, shall indicote their aworeness about their property having been inspected for Asbestos Containing Materials (ACM's).
A I do not know if an asbestos inspection has been conducted on this property.
tr An asbestos inspection has been conducted on this property on or about (enter date)
tr An asbestos inspection has not been conducted on this property.
Applicant: I hereby acknowtedge that I have read this application and state that the above information is correct and agree to
comply with all requirements herein alC City of Fort Collins ordinances and state laws regulating building construction.
Applicant Signature Type or Print Name John Bridgham
Phone # 97 37 Emait sundeckdesigns@aol.com
T*tS t\PpLitkTiAN tY?i'ft'f.$ t8* AAYS F*OM A7t"t.tteTl#N *f^Tf.
Submittal Checklist
Permit Application
Builder: Contractor or Homeowner
Affidavit
Deck info filled out (page 4)
Site Plan (PDF drawn to scale)
Plans set (PDF drawn to scale)
including :
Floor Plan,
Side view/elevation
Connection details
At least 1 before photo showing
where the deck will be located.
Payment (check, cash, credit card)
Required Inspections
1.Setback and Footing (Pier Hole)
2.Foundation (post connections)
3.Rough Frame & Rough Electric
4.Final Inspection
Engineered and stamped structural plans or letter is
required for the following conditions:
1.Beam supported by hangers
2.Ledger attached to a cantilever/overhang on the
existing house such as a bay window
3.Kits or pre-manufactured designs
4.Designs other than those presented in code.
5.Decks attached to brick, masonry or veneer.
6.Decks supporting a hot tub/pool.
7.Multi-story stacked decks
8.Steel decks that do not conform to section R505,
including the use of steel beams, or steel decks for
properties located West of Overland Trail (>140
mph wind region)
Homeowner Affidavit or Authorized Contractor License:
A, B, C, C2, D, D2, MM (MM does not include 2 story decks)
Residential Deck Guide
Option #1: The Deck is Engineered
Plans are provided and stamped by a Colorado Licensed Structural Engineer.
Option #2: I am designing to code (current adopted International Residential Code)
I have used the code link below to design my plans per code to the best of my ability.
Plans that do not meet code, will need to be re-designed / re-submitted or engineered.
Will the deck be attached to the house or self-supported?
What is the area (square feet) of the proposed deck?
Code Access (2018 IRC & local amendments)
https://codes.iccsafe.org/content/IRC2018
Chapter 5 - Section 507 Exterior Decks
https://www.fcgov.com/building/codes.php
A permit is required for any of the following conditions: Decks that are more than 30” above grade,
attached to the house, or serve the front exit door.
12/17/2020
(check options on page 4)
(Fill out page 4)
4
Attached to house
252
4
4
4
4
4
4
4
4
4
Step B: Draw a floor plan as if looking down from above.
3’-0” min
2
Tributary area
for each pier.
Table 507.3.1
Show location of the new structure in relation to the house
Provide measurements from deck to property lines
8.5x11 or 8.5x14 page size
Newer homes may have an existing site plan available
through public records, which can be used to create the NEW site plan.
http://citydocs.fcgov.com/
Step C: Draw an Elevation view (Side View)
Step A: Draw a site to scale (i.e.: 1”=20’-0”)
Residential Deck Guide
1
3
5
7
9
5
20 sf 40 sf
20 sf
4
4
4
4
6
9 9 LATERAL CONNECTION
Code Safety List
1.Handrails are required on at least one
side of the stairs where there are 4 or
more risers (landing to landing) and
must be graspable.
IRC Section: R311.7.8 – R311.7.8.6
2.Guards are required for fall protection where
the deck is 30” or more above grade
(measured at a point 5 ft away from the deck edge –
local amendment to definition of grade).
Openings in guards cannot exceed 4 inches
IRC Section: R312.1.1 - R312.1.4 (For cable railing use
3” max spacing and a maximum of 4ft on center support post spacing).
3.Where decks are built over window wells that serve the required emergency escape
and rescue opening (egress windows), a clear access height of 36” is required
(measured from the top of the window well to the underside of the deck structure). IRC
R310.2.4
4.Exterior wet listed light is required at the top landing to illuminate stairs. IRC Section
R311.7.9
5.A solid level landing is required at the bottom of exterior deck stairs sized 36” min deep
(in the path of travel) x 36” min wide (or width of stair) level concrete landing is required
at the bottom of exterior deck stairs. IRC Section: R311.7.6
Step D: Draw connection details showing how beams, joists, posts and piers are connected (see
section 5 for code sections and examples)
Residential Deck Guide
8
¾” 1¾”
1¾”- 2 ¾”max
Type l
Type ll
Topic Code Section Fill in required items
Decking
Material and orientation to joists Table R507.7
Joists
Species and size of joists Table 507.6
Span/length of joists Table & Figure R507.6
Do the joists cantilever? If so, how far? Figure & Table R507.6
(right column in table)
Spacing of joists (measured center to
center)
Table R507.6
Beams
Wood Species and size of beam Table R507.5
Span/ length of beam between posts Table R507.5
Does the beam cantilever? How far? Text Section R507.5
Joists to beam connections (See Step D)
Draw connection detail with fasteners Figures R507.5.1- R507.5.2 Show on Plans
Posts
What is the height of the deck Table R507.4
What is the size of the post Table R507.4
Beam to post connections (See Step D)
Draw connection detail with fasteners R507.5.1 & R507.5.1(2) Show on Plans
Pier/Footing size (See Steps B & C)
Required 30” min deep below grade Local Frost Depth 30 inches min. Deep
Type of footing/piers Text R507.3 & Figure R507.3 Show on plans
Size of footing/piers Table R507.3.1
Use 40psf snow load
Use 1,500 psf Soil Bearing
Post to pier/footing connections (See Step C)
Show connection details on plans R507.4.1 & R507.3 Show on plans
Ledger /Band joist Connection
How will the joists connect to the
house?
Section R507.8 - 507.9.2 &
Table R507.2.3
Show on plans
1
2
3
4
5
6
7
8
9
Step E: Provide deck design info:
Residential Deck Guide
https://codes.iccsafe.org/content/IRC2018 (chapter 5) https://www.fcgov.com/building/codes.php
I am submitting professionally engineered, stamped deck plans. I have confirmed that all of the following
required fields are provided on the engineered plans. Any fields not provided on the plans have been filled
out in the form fields below as needed (ie. deck height/ materials).
I am designing to code. All fields below must be filled out and noted on plans.
Check one of the following:
4
Composite Perpendicular
Southern Pine 2 x 8
9'10
22-1/2"
Yes
16" on center
Southern Pine 2 -2x8
6'-2"
yes - 12"
+/- 32"
4x4 nom.
2- 15" x 30" deep (outer)
2 - 18" x 30" deep (inner)