HomeMy WebLinkAbout6232 SAKER CT - PERMITS - 2/5/2021Owner:VENNELL VICKI ANN/JAEGER MARY ELIZABETH
JOINT TRUST
6232 SAKER CT
FORT COLLINS,CO 80528-7037 Phone:202-997-4968
Zoning:Front setback:Rear setback:23'Right setback:Left setback:
Minor Amend #:Plat File #:ZBA Case #:
Zoning district:UE -URBAN ESTATE DISTRICT
Legal:Subdivision/PUD:Filing #:Lot #:1 Block #:18
Code:Res sq ft:80 Com sq ft:Ind sq ft:Basement sq ft:
#of stories:Occ Group:Const Type:
Fire Sprklr:Stock plan #:Stock plan options:
Contractor:TNT HOME IMPROVEMENT
1448 ANTERO DR
LOVELAND,CO 80538
License #:MM-2007
Phone:970-217-1530
Supervisor cert #:
Subcontractor(s)Phone License Number
Misc &Minor Struct:TNT HOME IMPROVEMENT 970-217-1530 MM-2007
Work Description:Extend existing deck out 80 sq.ft.and building new landing/stairs.Work to also include extending gable cover out
80 sq.ft.Job contact:Tad Bjorlie 970-663-2868.
SCHEDULE INSPECTIONS:**via Text Message:888-406-6394 **By Phone:970-221-6769
**Online Portal:fcgov.com/CitizenAccess **Online Portal via Mobile Device:fcgov.com/CitizenAccess/mobile
Possible Inspections Required:101 100 203 303
TOTAL FEES PAID AS OF 02/05/21:$739.65 Payment method:Credit Card 6279
**Fee Detail Displayed on Next Page
As a condition for the issuance of a permit,I hereby declare that I am the owner or owner's agent,authorized to perform the proposed work on the property described herein.
I agree to comply with all the requirements contained herein,and City ordinances,and State laws associated with such work.I understand that such permit may be
revoked in the event that issuance was based on incorrect information.This permit shall become null and void if the work authorized by such permit is not commenced,
suspended,abandoned or not inspected within 180 days from the date of such permit.
Community Development &Neighborhood Services
281 N.College Ave Fort Collins,CO 80522
970.221.6760 970.224.6134 -fax
Building Permit #:B2100375
Issued Full:02/05/2021
Permit Type:Deck
Site Address:6232 SAKER CT
Job Valuation:$16,200.00 Category:Single Family Detach Res
Signature:Print Name:Date:
Form Revised Oct 2010
Transactions
Method Check Number Date Paid Amount Paid Comments
Credit Card CK #6279 02/05/2021 $596.65
Credit Card CK #1465 01/19/2021 $143.00
Receipt issued:02/05/2021 Total Paid to Date:$739.65
Fee Description Account Code Fee Amount Amount Paid Date Paid Amount Due
Building Permit Fee Without
Subs
1000.422010 $220.00 $220.00 02/05/2021 $0.00
City Sales/Use Tax 251.122030 $311.85 $311.85 02/05/2021 $0.00
County Sales/Use Tax 100.217030 $64.80 $64.80 02/05/2021 $0.00
Plan Check Fee 1000.444010 $143.00 $143.00 01/19/2021 $0.00
TOTAL FEES:$739.65 $739.65 $0.00
TOTAL BALANCE DUE AS OF 02/05/2021:$0.00
Community Development &Neighborhood Services
281 N.College Ave Fort Collins,CO 80522
970.221.6760 970.224.6134 -fax
Building Permit #:B2100375
Issued Full:02/05/2021
Permit Type:Deck
Site Address:6232 SAKER CT
Job Valuation:$16,200.00 Category:Single Family Detach Res
Fee Amounts are valid for date of this document only.Fees subject to change without notice.
Form Revised Oct 2010
BUILDING PERMIT APPLICATION
FOR OFFICE USE
APPLICATION NUMBER: APPLICATION DATE:
Job Site Address Unit#
PROPERTY OWNER INFO: (All owner information is required – NOT optional)
Last Name First Name Middle
Street Address City State Zip
Phone # Email
Name of Business (COMMERCIAL USE ONLY)
CONTRACTOR INFO: Company Name
License Holder Name LIC # CERT #
LEGAL INFO:
Subdivision/PUD Filing # Lot # Block # Lot Sq Ft
CONSTRUCTON INFO: Total Building Sq Ft (NOT including basement) Total Garage Sq. Ft.
Residential Sq Ft Commercial Sq Ft # of Stories Bldg Ht # of Dwelling Units
1st Floor Sq Ft 2nd Floor Sq Ft 3rd Floor Sq Ft Unfinished Basement Sq Ft
Finished Basement Sq Ft # of Bedrooms # of Full Baths
¾ Baths ½ Baths # Fireplaces
ENERGY INFORMATION: (CHECK ONE)
ComCheck ܆܆ UA (ResCheck) ܆܆ SPA (Simulated Performance
Alternative) ܆܆ Prescriptive܆܆ ERI(Energy Rating Index) ܆܆
Air Conditioning? YES տտ NO ܆܆
City of Fort Collins Approved Stock Plan # SP0 List Option #s
UTILITIES INFO: Gas տտ Electric ܆܆ Electric Temp. Pedestal Yes ܆܆No ܆܆
Electric Main Breaker Size (Residential Only): 150 amp or less ܆܆ 200 Amp ܆܆ Other տտ
ZONING INFO: (COMMERCIAL USE ONLY)
Proposed Use: (i.e. medical, office, bank, retail, etc.)
For Commercial remodels and tenant finishes, please answer the following questions:
Is the remodel/tenant finishes for an existing or new tenant? (Please check one)
Existing Tenant ܆܆New Tenant ܆܆
If for a new tenant, is this the first tenant to occupy this space?
Yes ܆܆No ܆܆ If not for the initial tenant for this unit, what was the previous use of this tenant space?
Are there any exterior building changes (including mechanical) associated with the work? Yes ܆܆ No ܆܆
If yes, please describe:
COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES
281 N. College Ave. xx Fort Collins, CO 80524 x Phone: 970.416.2740 x www.fcgov.com/building
TNT llc
Tad Bjorlie
Fort Collins CO
6232 Saker Ct
Jaeger Beth
6232 Saker Ct 80528
202-997-4968
1/19/21B2100375
Value of Construction (materials and labor): $
Description of Work:
JOBSITE SUPERVISOR CONTACT INFO: Name Phone
SUBCONTRACTOR INFO: Electrical Mechanical
Plumbing Framing Roofing
Fireplace Solar Other
ASBESTOS STATEMENT DISCLOSURE: In accordance with the State of Colorado Senate Bill 13-152, property owners, applying for a
remodel permit, shall indicate their awareness about their property having been inspected for Asbestos Containing Materials (ACM's).
տ I do not know if an asbestos inspection has been conducted on this property.
տ An asbestos inspection has been conducted on this property on or about (enter date)
տ An asbestos inspection has not been conducted on this property.
Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to
comply with all requirements contained herein and City of Fort Collins ordinances and state laws regulating building construction.
Applicant Signature Type or Print Name
Phone # Email
THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE
Tad Bjorlie 970-663-2868
x
Tad Bjorlie
jordin@tnthomeimprovements.com970-663-2868
16,200.00
Extend existing deck out additional 4'x20' and build new landing/stairs - extend existing gable cover
out 4'x20'
Egger's Electric
Digitally signed by Tad Bjorlie
DN: CN=Tad Bjorlie, C=US, OU=T-N-T llc, O=TNT Home
Improvements, E=sales@tnthomeimprovements.com
Reason: I am the author of this document
Location:
Date: 2021-01-18 12:38:39
Tad Bjorlie
Submittal Checklist
Permit Application
Builder: Contractor or Homeowner
Affidavit
Deck guide filled out
Site Plan (2 copies)
Floor Plan (2 copies)
Side view / elevation (2 copies)
Connection details (2 copies)
At least 1 before photo showing
where the deck will be located.
Payment (check, cash, credit
card)
Required Inspections
1.Setback and Footing (Pier Hole)
2.Foundation (post connections)
3.Rough Frame & Rough Electric
4.Final Inspection
Engineered and stamped structural plans or letter is
required for the following conditions:
1.Beam supported by hangers
2.Ledger attached to a cantilever/overhang on the
existing house such as a bay window
3.Kits or pre-manufactured designs
4.Designs other than those presented in code.
5.Decks attached to brick, masonry or veneer.
6.Decks supporting a hot tub/pool.
7.Multi-story stacked decks
8.Steel decks that do not conform to section R505,
including the use of steel beams, or steel decks for
properties located West of Overland Trail (>140
mph wind region)
Homeowner Affidavit or Authorized Contractor License:
A, B, C, C2, D, D2, MM (MM does not include 2 story decks)
Residential Deck Guide
Option #1: The Deck is Engineered
Plans are provided and stamped by a Colorado Licensed Structural Engineer.
Option #2: I am designing to code (current adopted International Residential Code)
I have used the code link below to design my plans per code to the best of my ability.
Plans that do not meet code, will need to be re-designed / re-submitted or engineered.
Will the deck be attached to the house or self-supported?
What is the area (square feet) of the proposed deck?
Code Access (2018 IRC & local amendments)
xhttps://codes.iccsafe.org/content/IRC2018
Chapter 5 - Section 507 Exterior Decks
xhttps://www.fcgov.com/building/codes.php
A permit is required for any of the following conditions: Decks that are more than 30” above grade,
attached to the house, or serve the front exit door.
✔
Self-supported
80 sq ft
Topic Code Section Fill in the blank
Decking
Material and orientation to joists Table R507.7
Joists
Species and size of joists Table 507.6
Span/length of joists Table & Figure R507.6
Do the joists cantilever? If so, how far? Figure & Table R507.6
(right column in table)
Spacing of joists (measured center to
center)
Table R507.6
Beams
Wood Species and size of beam Table R507.5
Span/ length of beam between posts Table R507.5
Does the beam cantilever? How far? Text Section R507.5
Joists to beam connections (See Step D)
Draw connection detail with fasteners Figures R507.5.1- R507.5.2 Show on Plans
Posts
What is the height of the deck Table R507.4
What is the size of the post Table R507.4
Beam to post connections (See Step D)
Draw connection detail with fasteners R507.5.1 & R507.5.1(2) Show on Plans
Pier/Footing size (See Steps B & C)
Required 30” min deep below grade Local Frost Depth 30 inches min. Deep
Type of footing/piers Text R507.3 & Figure R507.3 Show on plans
Size of footing/piers Table R507.3.1
Use 40psf snow load
Use 1,500 psf Soil Bearing
Post to pier/footing connections (See Step C)
Show connection details on plans R507.4.1 & R507.3 Show on plans
Ledger /Band joist Connection
How will the joists connect to the
house?
Section R507.8 - 507.9.2 &
Table R507.2.3
Show on plans
1
2
3
4
5
6
7
8
9
Step E: Size all members using code (All blanks must be filled in and noted on plans)
Residential Deck Guide
https://codes.iccsafe.org/content/IRC2018 (chapter 5) https://www.fcgov.com/building/codes.php
Composite Perpendicular
Southern Pine 2 x 10
4'
4'Yes
16" on center
Southern Pine 2 -2x10
10'
No
5'
6x6
12"x30"