HomeMy WebLinkAbout2026 BEAR MOUNTAIN DR - 101 - SPECIAL INSPECTIONS - 3/19/2021Page 1 of 2
BUILDING INSPECTION RECORD
Lofts at Timberline (2026 Bear Mountain Drive)
Owner: Omnia Cum Deo
Contact: Keith Meyer, P.E.
Project Name: Lofts at Timberline
Project Number: N/A
Building 2026 Bear Mountain Drive
Local Building Official: City of Fort Collins Building Permit No: B2013756
Architect/Engineer: R4 Architects / Ditesco LLC Type of Construction: Type III-B
Contractors: General: Elder Construction Occupancy Classifications: B, S
Electrical: APS, Inc. Total Building Area: 4,575 sf
Mechanical: Integrated Mechanical
Plumbing: Integrated Mechanical
Building General Date Inspector
☒ Footings/Foundations
Comments: Under separate permit for Core & Shell. N/A N/A
☒ Concrete Slab / Under-Floor
Comments: Concrete slab was constructed in accordance with plans and specifications. 2/9/2021 KP-Ditesco
☐ Light Gauge Framing
Comments: N/A N/A N/A
☐ Sheathing
Comments: N/A N/A N/A
☐ Fire-Resistant Penetrations
Comments: N/A N/A N/A
☐ Mechanical/Energy Efficiency
Comments: N/A N/A N/A
☐ Roofing
Comments: N/A N/A N/A
☐ Other
Comments: N/A N/A N/A
☐ Final
Comments: N/A N/A N/A
Special Date Inspector
☒ Bolt/Weld Inspection
Comments: Beam-Beam and Beam-Column Bolting Inspected. Installed in accordance with PEMB Engineer
and project plans and specifications. 2/24/2021 KP-Ditesco
☒ Special Structural Concrete
Comments: The mezzanine composite slab was constructed in accordance with the plans and specifications. 2/25/2021 KP-Ditesco
☐ Masonry
Comments: N/A N/A N/A
☐ Wood
Comments: N/A N/A N/A
☐ Soils/Foundations
Comments: N/A N/A N/A
☐ Spray-Applied Fireproofing
Comments: N/A N/A N/A
☐ Control Systems
Comments: N/A N/A N/A
2133 S. Timberline Rd. – Suite 110
Fort Collins, CO 80525
ditescoservices.com
Delivery via e-mail to:
keith.meyer@ditescoservices.com
March 10, 2021
Mr. Keith Meyer, P.E.
Omni Cum Deo
2133 S. Timberline Rd STE 110
Fort Collins, CO 80525
RE: Bolt Inspection 2-24-2021 (Dutch Brothers HQ)
Dear Keith:
The following inspection was performed on February 24, 2021
Location/Project: Lofts at Timberline, 2021, 2027 and 2033 S Timberline Rd (parcels #8719144006, 8719144007,
8719144004)
Inspector: Kelsey Petersen
Inspection Type: Visual, High Strength Bolt (AISC Spec. for Structural Joints Using ASTM A325 or A490 Bolts,
Sect. 8,9)
Observations: Structural connections at beam-to-beam and beam-to-column locations at Dutch Brothers HQ
mezzanine. Inspection was at 10% frequency to hand tight condition per ASTM and Project Specifications. Bolts
observed to not be tightened to hand tight condition were tightened before completion of observation. 100% of
inspected bolts were in acceptable condition prior to completion of observation.
PEMB Plans by:
Dutch Brothers HQ – RA Architects, Job # RRE20468, drawn on 2/15/2021
PEMB Steel supplied by: Hueber Industries
At the time of our observation, the items observed met the quality standards listed above: Yes
Discrepancies were observed, see attached discrepancy list: No
Please let me know if you have any questions regarding this monthly progress report or the attached invoice. I can
be reached by phone at 970.820.0175 or email bill.renz@ditescoservices.com.
Sincerely,