Loading...
HomeMy WebLinkAbout5206 FOSSIL CREEK DR - SPECIAL INSPECTIONS - 2/17/2021 TD Structural Engineering, Inc. | 2909 Oxford Ct., Fort Collins, CO 80525 | 970.372.1140 | www.tdstructural.com February 17, 2021 Hammersmith Structures 201 Commerce Drive #1 Fort Collins, Colorado Project: Pearson Residence Location: 5206 Fossil Creek Drive, Fort Collins, Colorado TDSE Project No.: 20-024 Plans/Details: Plans by TD Structural Engineering dated 4/29/20, revised 6/12/20 Observation Dates: December 4th, 2020 Items Observed: framing Notes: Observations indicate the framing is in substantial conformance with the plans as noted above with the following exceptions: • There was a single 2x6 stud instead of a 2-2x6 required to support Girder truss G1 at the detached garage. An additional 2x6 has since been added. • The STHD holdown straps at the detached garage were misplaced. HDU8 holdowns have been installed in the correct locations. • There were a few ledgerloks for the upper-level roof trusses that missed the studs. Additional ledgerloks were added and were installed correctly. • The W10x22 steel beam to post connection was missing during the time of our observation. This has since been fixed with a welded connection, two opposite sides. • Three additional 7¼” LVL kings studs were added to the west side of the two-story entry window to transfer lateral forces. • The ten 2x6 king studs and post have been strapped per our request. Please let me know if you have any questions. Sincerely, Jordan M. Halvorson Wendy Thomas Dworak, P.E. Associate Engineer President TD Structural Engineering Inc. TD Structural Engineering Inc.