Loading...
HomeMy WebLinkAbout3349 GREEN LAKE DR - 03 - DISCLOSURES - 3/22/2021Testing Company: Name:Green Insight, LLC Address:917 E Prospect Rd, Unit B Fort Collins, CO 80525 Phone: 833-476-8326 www.thegreeninsight.com Technician: Name:Ryan Moore Credentials:RTIN 537080 Email:rmoore@thegreeninsight.com Building Information: Project ID:3349 Green Lake #3 Address:3349 Green Lake Dr., #3 Fort Collins, CO 80524 Geo-Tag Data:Latitude: Longitude: Timestamp: Customer Information: Name:Townhomes On Vine Address:208 S College #B For t Collins, CO 80524 Phone: 970-632-1067 Email: ceri @trailheadhomes.com Measured Leakage:1.94 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:1 Purpose of Test:RESNET ANSI 380 ACH50 Measured CFM50:753.3 (+/- 0.8%)Effective Leakage Area: 34.8 in² Building Volume:23,318.0 ft³Enclosure Surface Area: 5,225.0 ft² Coefficient (C):45.3 (+/- 2.9%)Exponent (n): 0.719 (+/- 0.009) Correlation Coefficient:0.99998 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 60 °F Altitude: 5,000.0 ft Outdoor Temp: 46 °F Time Average Period: 10 seconds Test Date and Time:2021-03-22 15:27:01 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -1.5 -60.0 -59.8 -58.3 -199.0 835.7 Ring B -48.0 -50.2 -48.7 -155.3 739.0 Ring B -35.0 -37.1 -35.7 -99.6 593.0 Ring B -23.0 -25.2 -23.8 -54.4 439.7 Ring B -10.0 -9.2 -7.7 -75.1 196.0 Ring C Test Equipment: Flow Device: Model 3 110V Fan Pressure Gauge: DG1000 Serial #: 6325 Calibration Date: 2020-08-27 Deviations from Standard: None Comments: House pressure WRT garage = -49.9 Pa Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.7.2 (106), © 2020 The Energy Conservatory, Inc. Ryan J. Moore