Loading...
HomeMy WebLinkAbout3343 GREEN LAKE DR - 02 - DISCLOSURES - 3/22/2021Testing Company: Name:Green Insight, LLC Address:917 E Prospect Rd, Unit B Fort Collins, CO 80525 Phone: 833-476-8326 www.thegreeninsight.com Technician: Name:Ryan Moore Credentials:RTIN 537080 Email:rmoore@thegreeninsight.com Building Information: Project ID:3343 Green Lake #2 Address:3343 Green Lake Dr., #2 Fort Collins, CO 80524 Geo-Tag Data:Latitude: Longitude: Timestamp: Customer Information: Name:Townhomes On Vine Address:208 S College #B For t Collins, CO 80524 Phone: 970-632-1067 Email: ceri @trailheadhomes.com Measured Leakage:1.78 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:1 Purpose of Test:RESNET ANSI 380 ACH50 Measured CFM50:693.5 (+/- 1.2%)Effective Leakage Area: 37.5 in² Building Volume:23,318.0 ft³Enclosure Surface Area: 5,225.0 ft² Coefficient (C):53.3 (+/- 4.4%)Exponent (n): 0.656 (+/- 0.013) Correlation Coefficient:0.99994 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 61 °F Altitude: 5,000.0 ft Outdoor Temp: 54 °F Time Average Period: 10 seconds Test Date and Time:2021-03-22 13:41:40 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -2.3 -60.0 -62.1 -59.8 -172.2 777.9 Ring B -48.0 -51.0 -48.7 -128.4 672.6 Ring B -35.0 -38.5 -36.1 -86.1 551.6 Ring B -23.0 -26.0 -23.7 -49.4 418.8 Ring B -10.0 -9.8 -7.5 -77.1 198.7 Ring C Test Equipment: Flow Device: Model 3 110V Fan Pressure Gauge: DG1000 Serial #: 6325 Calibration Date: 2020-08-27 Deviations from Standard: None Comments: House pressure WRT garage = -49.5 Pa Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.7.2 (106), © 2020 The Energy Conservatory, Inc. Ryan J. Moore