Loading...
HomeMy WebLinkAbout1133 BON HOMME RICHARD DR - DISCLOSURES - 12/16/2020BUILDING LEAKAGE TEST Date of Test: 12/16/2020 Test File: 1133 Bon Homme Richard Dr 2.95ACH 3.29.2021 Technician:Sam Chaney/ EnergyLogic Project Number: Customer:Lokal Homes Phone: Fax: Building Address: 1133 Bon Homme Richard Dr Fort Collins, CO 80526 Test Results at 50 Pascals: cfm50 Airflow 1064 (+/- 4.8 %) ACH50 2.95 Leakage Areas:51.8 in² (+/- 29.0 %) Canadian EqLA @ 10 Pa 18.0 in² (+/- 44.6 %) LBL ELA @ 4 Pa Building Leakage Curve:Flow Coefficient (C) = 13.5 (+/- 68.4 %) Exponent (n) = 1.117 (+/- 0.172) Correlation Coefficient = 0.99650 Test Standard:E779-10 Test Mode:Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 90 Building Pressure (Pa) 60 70 80 90 100 200 300 400 500 600 700 8009001000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/16/2020 Test File: 1133 Bon Homme Richard Dr 2.95ACH 3.29.2021 Building Information Volume (ft³)21657.0 Surface Area: (ft²) Floor Area: (ft²) Height (ft)25 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/16/2020 Test File: 1133 Bon Homme Richard Dr 2.95ACH 3.29.2021 Depressurization Test: Environmental Data Indoor Temperature (°F)Outdoor Temperature (°F)Altitude (ft) Pre-Test 72.0 66.0 Post-Test 72.0 66.0 Average 72.0 66.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm)% Error Fan Configuration 11.0 n/a n/a -60.0 -74.5 73.9 73.9 1549 1712 3.1 Ring A -50.0 -64.5 49.6 49.6 1276 1409 -0.3 Ring A -40.0 -54.5 298.1 298.1 1021 1128 -3.7 Ring B -30.0 -44.5 197.7 197.7 833 920 -1.5 Ring B -20.0 -34.5 121.0 121.0 653 722 2.6 Ring B 18.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters -n value (1.117) outside of acceptable limits (0,5 ≤ n ≤ 1). -Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/16/2020 Test File: 1133 Bon Homme Richard Dr 2.95ACH 3.29.2021 Comments -48 pa house to garage connection