Loading...
HomeMy WebLinkAbout526 VICOT WAY - DISCLOSURES - 3/9/2021BUILDING LEAKAGE TEST Date of Test: 3/9/2021 Test File: 526 Vicot Way 2.37 ACH 3.9.2021 Technician:Sam Chaney/ EnergyLogic Project Number: Customer:Lennar Phone: Fax: Building Address: 526 Vicot Way Fort Collins, CO 80521 Test Results at 50 Pascals: cfm50 Airflow 1124 (+/- 3.6 %) ACH50 2.37 Leakage Areas:95.5 in² (+/- 10.2 %) Canadian EqLA @ 10 Pa 45.5 in² (+/- 16.8 %) LBL ELA @ 4 Pa Building Leakage Curve:Flow Coefficient (C) = 55.1 (+/- 27.0 %) Exponent (n) = 0.771 (+/- 0.074) Correlation Coefficient = 0.99863 Test Standard:E779-10 Test Mode:Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 9001000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/9/2021 Test File: 526 Vicot Way 2.37 ACH 3.9.2021 Building Information Volume (ft³)28403.44 Surface Area: (ft²) Floor Area: (ft²) Height (ft)28 Year of Construction 2021 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/9/2021 Test File: 526 Vicot Way 2.37 ACH 3.9.2021 Depressurization Test: Environmental Data Indoor Temperature (°F)Outdoor Temperature (°F)Altitude (ft) Pre-Test 66.0 61.0 Post-Test 66.0 61.0 Average 66.0 61.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm)% Error Fan Configuration 0.0 n/a n/a -20.0 -20.0 82.4 82.4 540 559 0.8 Ring B -30.2 -30.2 149.0 149.0 724 750 -1.6 Ring B -40.1 -40.1 235.3 235.3 908 940 -0.8 Ring B -50.0 -50.0 37.6 37.6 1114 1154 2.7 Ring A -60.0 -60.0 46.4 46.4 1235 1279 -1.1 Ring A 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters -An interval between building pressures exceeds 10 Pa. -Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/9/2021 Test File: 526 Vicot Way 2.37 ACH 3.9.2021 Comments -45 pa house to garage connection