Loading...
HomeMy WebLinkAbout910 HILL POND RD - 17 - SPECIAL INSPECTIONS - 2/27/2019617 0 5-67 Z February 27, 2019 Mr. Rich Laue Schuman Construction 500 Goodman St. er COFFEY ENGINEERING & SURVEYING 4045 St. Cloud Drive, Suite 180 Loveland, CO 80538 [P] 970-622-2095 [F] 970461-4469 Timnath, CO 80547 � �11 Re: 910 Hill Pond Road, Fort Collins, CO 80526, Lots 17 & 18, Shear Wall Observation Letter Dear Mr. Laue, Coffey Engineering and Surveying (Coffey) conducted, at your request, a shear wall observation on 2/27/2019 of Lots 17 and 18 within the Hill Pond Duplex development. This included the exterior shear walls, the demising wall between the units, and the walls that separate the garage from the interior space of the units. It is Coffey`s professional opinion that the items observed pertaining to the shear wall fastening and sheathing appear to be in general compliance with the Coffey Engineering structural plans dated 3/8/2018. Coffey only visually observed the items noted above. No warranty is either expressed or implied for the construction of the shear wall framing. If you have any questions or if you require further observation - concerning this structure, please call us at (970) 622-2095. Sincerely, COFFEY ENGINEERING & SURVEYING, LLC Deacon Maggard, El Structural Design Engineer I Troy Campbell, PE Project Manager