Loading...
HomeMy WebLinkAboutCROWNE ON TIMBERLINE - PDP - PDP130009 - CORRESPONDENCE - (4)Fort Collins Green Code Amendments effective starting 1-1-2012. A copy of these requirements can be obtained at the Building Office or contact the above phone number. City of Fort Collins Building Services Plan Review 416-2341 Request will need to be submitted with your formal development proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply for a Modification of Standard. 8. Please see the Submittal Requirements and Checklist at: http://www.fcgov.com/developmentreview/applications.php. 9. The request will be subject to the Development Review Fee Schedule that is available in the Community Development and Neighborhood Services office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal. 10. When you are ready to submit your formal plans, please make an appointment with Community Development and Neighborhood Services at (970)221-6750. Pre -Submittal Meetinqs for Building Permits Pre -Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi -family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi -family projects are advised to call 416-2341 to schedule a pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2009 International Building Code (IBC) 2009 International Residential Code (IRC) 2009 International Energy Conservation Code (IECC) 2009 International Mechanical Code (IMC) 2009 International Fuel Gas Code (IFGC) 2009 International Plumbing Code (/PC) as amended by the State of Colorado 2011 National Electrical Code (NEC) as amended by the State of Colorado Accessibility: State Law CRS 9-5 & ICC/ANSI Al17.1-2003. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2009 IRC Chapter 11 or 2009 IECC Chapter 4 2. Multi -family and Condominiums 3 stories max: 2009 IECC Chapter 4. 3. Commercial and Multi -family 4 stories and taller: 2009 IECC Chapter 5. costs paid for by the applicant. 13. A Development Construction Permit (DCP) will need to be obtained prior to starting any work on the site. Department: Electric Engineering Contact: Alan Rutz, 970-224-6153, arutz(@fc_qov.com 1. Electric Development charges will apply. 2. Large buildings will need to be 3 phase. Submit C-1 form and coordinate transformer locations. 3. Each dwelling unit will need to be separately metered. 4. Buildings may require fire pumps. Contact Light and Power ffor electric requirements. 5. Electric lines are located behind the curb with water and sewer under the asphalt. Water and sewer lines for the single family will need to be relocated to allow room for electric lines and transformers. 6. Coordinate load requirements and transformer location for clubhouse. 7. Gang meters on single family and coordinate meter locations with Light and Power. Current Planning Contact: Seth Lorson, 970-224-6189, slorson a()fcclov.com 1. Please look closely at the block standards in LUC Div. 4.6(E). It appears you are not meeting the building frontage requirement. Please provide an analysis of your proposed blocks and how they meet the aforementioned standards. 2. Although we have yet to review architectural elevations, please look closely at the standards in LUC Div. 4.6(E)(3). 3. Internal private drives are required to meet the standards found in 3.6.2(L). 4. The proposed development project is subject to a Type 2 (Planning and Zoning Board) review and public hearing. The applicant for this development request is required to hold a neighborhood information meeting prior to formal submittal of the proposal. Neighborhood meetings offer an informal way to get feedback from your surrounding neighbors and discover any potential iccups prior to the formal hearing. Please contact me, at 221-6750, to assist you in setting a date, time, and location. I and possibly other City staff, would be present to facilitate the meeting. 5. Please see the Development Review Guide at www.fcgov.com/drg. This online guide features a color coded flowchart with comprehensive, easy to read information on each step in the process. This guide includes links to just about every resource you need during development review. 6. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code (LUC), including Article 3 General Development Standards. The entire LUC is available for your review on the web at http://www.colocode.com/ftcollins/landuse/begin.htm. 7. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a Modification of Standard 1. Though this site is wtihin 450' of a natural habitat or feature (emergent wetlands, aquatic features, and a riparian forest), an Ecological Characterization Study will not be required because the closest feature maximum buffer that could be applied would be 300'. In other words, no buffer standards would reach the property, should they be applied, and thus, an ECS is not required. 2. With respect to landscaping and design, the City of Fort Collins Land Use Code, in Article 3.2.1 (E)(2)(3), requires that you use native plants and grasses in your landscaping or re landscaping and reduce bluegrass lawns as much as possible. Reveille Bluegrass is one option for having bluegrass lawns and using less water. Department: Engineering Development Review Contact: Marc Virata, 970-221-6567, mviratapfcgov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 if you have any questions. 2. The City's Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see: http://www.fcgov,com/engineering/dev-review.php 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 4. Please contact the City's Traffic Engineer, Joe Olson (224-6062) to schedule a scoping meeting for a traffic study needed for this project. In addition, please contact Transportation Planning for their requirements as well. 5. Any public improvements (public streets) must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). They are available online at: http://www.larimer.org/engineering/GMARdStds/UrbanSt.htm 6. Timberline Road will need to be designed and improved to its ultimate condition (sidewalk, pavement, curb & gutter) abutting the property with transitions as required. 7. Section 3.6.3 of the Land Use Code should be reviewed for verification of overall compliance to this section. Section 3.6.3(F) would require the continuation of White Willow Drive into the development, unless alternative compliance to this section is proposed and granted. 8. Public streets are required to have right-of-way dedicated without any encumbrances. Irrigation lines that cross right-of-way would need approval through an encroachment permit process. Irrigation lines would need to have sufficient cover over the top of the pipe to the pavement subgrade in accordance to LCUASS criteria and be encased with tracer wire installed across the length of right-of-way. 9. If the access onto Timberline Road is determined to potentially be interim, guarantees would need to be in place prior to any building permit for the costs associated the closing off of the access onto Timberline Road. The design for the "ultimate" condition would need to be included with the project. 10. This project is responsible for dedicating any right-of-way and easements that are necessary for this project and/or in conformance with the City's Master Street Plan, 11. Construction plans will be required. 12. A Development Agreement will be required and recorded once the project is finalized with recordation 7. The design of this site must conform to the drainage basin design of the Fossil Creek Basin Master Drainage Plan as well the City's Design Criteria and Construction standards. Department: Fire Authority Contact: Jim Lynxwiler, 970-416-2869, ilynxwiler(a)poudre-fire.org 1. DEAD-END FIRE LANES Dead-end fire access roads in excess of 150 feet in length shall be provided with an approved area for turning around fire apparatus. FCLUC 3.6.2(B)2006; International Fire Code 503.2.5 and Appendix D 2. TURNING RADII The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside and 50 feet outside. International Fire Code 503.2.4 and Local Amendments 3. WATER SUPPLY Hydrant spacing and flow must meet minimum requirements based on type of occupancy. Commercial requirements: Hydrants to provide 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter. 4. AUTOMATIC SPRINKLER SYSTEMS An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area. 2006 International Fire Code 903.2.7 5. BALCONIES AND DECKS Sprinkler protection shall be provided for exterior balconies, decks, and ground floor patios of dwelling units where the building is of Type V construction. 2006 International Fire Code 903.3.1.2.1 6. KEY BOXES REQUIRED Poudre Fire Authority requires at least one key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire sprinkler or fire alarm system. The top shall not be higher than 6 feet above finished floor. 2006 International Fire Code 506.1 and Poudre Fire Authority Bureau Policy 88-20 7. PREMISE IDENTIFICATION New and existing buildings shall be plainly identified. Address numbers shall be visible from the street fronting the property, plainly visible, and posted with a minimum of six-inch numerals on a contrasting background. 2006 International Fire Code 505.1 8. PUBLIC -SAFETY RADIO AMPLIFICATION SYSTEM New buildings or building additions that cause the building to be greater than 50,000 square feet will require a fire department, emergency communication system evaluation after the core/shell but prior to final build out. Where adequate radio coverage cannot be established within a building, public -safety radio amplification systems shall be installed. Department: Environmental Planning Contact: Lindsay Ex, 970-224-6143, lex(a)fcgov.com v 11. LUC 3.5.1(G) If any building is over 40ft in height than additional information is required for a special height review (see section for details). Department: Water -Wastewater Engineering Contact: Roger Buffington, , rbuffington@fcgov.com 1. Water and wastewater services in this area are provided by the Fort Collins -Loveland Water District and the South Fort Collins Sanitation District. The Districts may be contacted at 226-3104. 2. Water and wastewater services in this area are provided by the Fort Collins -Loveland Water District and the South Fort Collins Sanitation District. The Districts may be contacted at 226-3104. Department: Stormwater Engineering Contact: Glen Schlueter, 970-224-6065, gschlueterOfcgov.com 1. A drainage and erosion control report and construction plans are required and they must be prepared by a Professional Engineer registered in Colorado. The drainage report must address the four -step process for selecting structural BMPs. Standard operating procedures (SOPs) for all onsite drainage facilities need to be prepared by the drainage engineer and there is a final site inspection required when the project is complete and the maintenance is handed over to an HOA or another maintenance organization. The erosion control requirements are in the Stormwater Design Criteria Section 1.3.3. If you need clarification concerning this section, please contact the Erosion Control Inspector, Jesse Schlam at 224-6015 or jschlam@fcgov.com. 2. Onsite detention is required for the runoff volume difference between the 100 year developed inflow rate and the 2 year historic release rate. 3. Water quality treatment is also required as described in the Urban Storm Drainage Criteria Manual, Volume 3 - Best Management Practices (BMPs). (http://www.udfcd.org/downloads/down_critmanual_volill.htm) Extended detention is the usual method selected for water quality treatment; however the use of any of the BMPs is encouraged. 4. The drainage outfall for the site is to the south through Linden Park PDP. The design engineer will need to verify capacity in that system but it should have enough capacity for 2 yr. detained flows since it presently is sized for existing100 yr. flows from offsite. 5. The Stormwater Utility anticipates that City Council will be approving new Low Impact Development (LID) requirements in late January 2013. Please contact Basil Hamdan at 224-6035 or bhamdan@fcgov.com for more information. The present draft requires that 50% of the new impervious area must be treated by an LID method and 25% of new parking lots must be pervious. 6. The city wide Stormwater development fee (PIF) is $6,390.00/acre ($0.1467/sq.ft.) for new impervious area over 350 sq.-ft., and there is a $1,045.00/acre ($0.024/sq.ft.) review fee. No fee is charged for existing impervious area. These fees are to be paid at the time each building permit is issued. Information on fees can be found on the City's web site at http://www.fcgov.com/utilities/business/builders-and-developers/plant-investment-development-fees or contact Jean Pakech at 221- 6375 for questions on fees. There is also an erosion control escrow required before the Development Construction permit is issued. The amount of the escrow is determined by the design engineer, and is based on the site disturbance area, cost of the measures, or a minimum amount in accordance with the Fort Collins Stormwater Design Criteria. building frontage plazas or other functional open space. Buildings are limited to 3 stories. ` LUC 4.6(E)(2)(c) Minimum setback from a street ROW is none. LUC 4.6(E)(3)(a) 25ft Setback from the property line of abutting property containing single-family and two-family dwellings. 4. LUC 4.6(E)(3)(b) Developments with 5 to 7 buildings shall have at least 2 different building designs LUC 4.6(E)(3)(c) There shall be at least 3 distinct color schemes LUC 4.6(E)(3)(d) Entrance shall be made clearly visible from the streets and public areas through architectural elements and landscaping. LUC 4.6(E)(3)(e) Roof lines (see section for requirements) LUC 4.6(E)(3)(f) Facades of multi -family dwellings shall be articulated (see section for details) 5. LUC 3.2.2(C)(1) To the maximum extent feasible, pedestrians shall be separated from the vehicles and bicycles. This would include detached sidewalks along private/public streets and entries to the development. LUC 3.2.2(C) There shall be sidewalks that provide directness and continuity from building entries to street sidewalks that are at least 6ft in width. 6. LUC 3.2.2(C)(4) There shall be 1 bicycle parking space per bedroom for the development with at least 60% of the required spaces being enclosed and at least 40% of the required fixed. These space shall be located near the primary entrances of the buildings. 7. LUC 3.2.2(K) Vehicle parking is required it is based on the number of units and bedrooms (see section for details). LUC 3.2.2(K) Based on the number of vehicle parking spaces there is a required number of these that will need to be accessibility spaces. At least one of the accessibility spaces will need to be van accessible. These spaces shall be designated by a sign and located as close as possible to primary entrances to the buildings. LUC 3.2.2(L) Refer to tables and figures for stall dimensions. 8. LUC 3.2.5 Enclosures are required that are adequate for both trash and recycling. Such enclosures shall be designed with walk-in access without having to open the main service gate and located on concrete pad at least 20ft from a public sidewalk. 9. LUC 3.2.1 Landscape plan is required (see section for details). LUC 3.2.4 Lighting plan is required, which includes but not limited to a photometric site plan with catalog cutsheets (see section for additional details). 10. LUC 3.5.1(1) Plans (site,landscape and elevations) need to identify locations of Mechanical/Utility (vents, flues, ac/rtu, conduit, meters...) equipment and include a note on how such equipment will be screened/painted. �_ rt Collins January 07, 2013 Alon Levon Crowne Partners, Inc. w t c P cces S o a n MO-L' Community Development and FiCcf 5b �¢ab'�T 1"u , JCW Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com Re: 6111 S Timberline Rd - The Crowne on Timberline Multifamily Description of project: This is a request to construct 300 multifamily units consisting of 25 townhomes and 275 stacked flats at 6111 S Timberline Road. The multifamily complex will be situated on the Medium Density Mixed -Use Neighborhood District (M-M-N) portion of parcel# 8607400010. As the project contains 50+ multifamily units, it is subject to Planning & Zoning Board (Type 2) review. Please see the following summary of comments regarding the project request referrenced above. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you have any questions regarding these comments or the next steps in the review process, you may contact the individual commenter or direct your questions through the Project Planner, Seth Lorson, at 970-224-6189 or slorson@fcgov.com. Comment Summary: Department: Zoning Contact: Noah Beals, 970-416-2313, nbeals fcgov.com 1. Land Use Code (LUC) 4.6(D)(1) If the development is less than 20 acres than the minimum average density if 7 dwelling units per net acre. LUC 4.6(D)(2)(a) A minimum of 2 housing types. LUC 4.6(D)(2)(b) lots sizes shall vary with different housing types. LUC 4.6(D)(2)(d) Lot patterns (size and layout) shall allow building to face toward the street. 2. LUC 4.6(D)(3) 90% of the dwellings of the development project shall be located within a quarter -mile of central feature or gathering place (see section for further details). 3. LUC 4.6(E) Each development shall be developed as a series of complete blocks bounded with streets. Block sizes shall be limited to 7acres. Minimum 40% of each block side consist of either