HomeMy WebLinkAboutBid Tally -8370 TRANSFORMERS 25KVA & 100 KVA SINGLE PHASE PAD-MOUNTED1 Phase Padmounted Transformer Bid Evaluation
# Units
%fmr Type 1P Pad Bid if:
Size
IDb kVA SecondaryV 240,120 Date:
NL Loss Cost
$ 3 90 Stock # T120170
FL Loss Cost
$ 1.so
Specified
Impedance %
2.1 r (See Impedance Requirements Table in Specification)
Includes Winding's Sbay
Losses
Losses 8 Losses
sndated
Base Bid
Rank Based on
Rank Bassd on
Base Bid Guar No
Guar Total Associated oath A-hary
Winding's
with Aumliary
Impedance
Extended Cost NL Loss' NL FL
Loss' FL
Bid (1 is best
Evaluated bid (t
Supplier
Manufacturer $ / Each DeVWks Load Loss Guar Fue Load Loss
Impedance Meet Specs? Escalation Load Loss Devices (Yes / No)
Sbay Losses
Devices
Variance Evaluated Bic) (Total $) Loss
Cost Loss Cost
choice)
is best choice)
Wesco
ABB S 2,611.50 8 - 10 Weeks 152 863
2.15 Yes Not
1015 Yes
11
8
-OA2'0 $
4,498.80 $ 39,172.50 $
592.80 $
1,294.50
4 3
Western United
Central Moloney $ 2,110.00 12 161 921
2.04 Yes is not
1082 Yes
26
0
5.99°m $
4,119.40 $ 31,650.00 $
627.90 $
1,381.50
1 1
Irby
Eaton Cooper Powe$ 2.346.60 12 ISO 928
208 Yes Yes
1078 Yes
38,63
0
A, 15%$
4,323.60 $ 35,199.00 $
585.00 $
1.392.00
2 2
Western United
Howanl Industries $ 2,566.00 8-10 WKS ARC 196 789
2.10 Yes No
985 YES
32
0
-3.23% $
4,513.90 $ 38,490.00 $
764.40 $
1,183.50
3 4
0
-100.00% $
- $ - $
- $
-
NN/A
-
Notes:
1. it appears that ABB meets our specification.
2. Central Maloney does not provide any design documents with bid proposal but they appear to meet our specification
3, it appears that Cooper meets our specifications but some clarifications have been sent regarding multiple sections in our specification. They state they will not provide an internal marling for fluid levels at 25 deg C. A word document has been drafted and sent to gather/provide information irom/lor them.
4. From the bid documents, it appears that Howard Industries' footprint is 7' longer than our specification states however it will still fit on our 43' x 37' surface area. Also, Howard's u is are 3' taller than our specification allows however they still fall within C57.12.38's height limitations which is what we base our uit's dieter
Based on the ranking of the evaluated bids, Central Moloney care of Western United is the lowest evaluated responsible bidder and should be awarded Bid 8370.
IEEE C57.12.DO, Section 9.2 Tolerances for impedance
The tolerances for impedance shall be as follows:
a) The impedance of a two -winding transformer with an impedance voltage greater than 2.5%shall have a tolerance of±7.5%of the specified value, and those with an impedance voltage of 2.5% or
less shall have a tolerance of±10% of the specified value.
Differences of impedance between duplicate two -winding transformers, when two or mote units of a given rating are produced by one manufacturer at the same time, shall not exceed 7.5% of the
specified value.
b) The impedance of a transformer having three or more windings, or having zigzag windings, shall have a tolerance of ±10%of the specified value.
Differences of impedance between duplicate three -winding or zigzag transformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed
10%of the specified value.
c) The impedance of an autotransformer shall have a tolerance of±10% of the specified value. Differences of impedance between duplicate autotransformers, when two or more units of a given
rating are produced by one manufacturer at the same time, shall not exceed 10%of the specified value.
d) Transformers shall be considered suitable for operation in parallel when reactances come within the limitations of the preceding paragraphs, provided that turns ratios and other controlling
characteristics are suitable for such operation.
No Text
1 Phase Padmounted Transformer Bid Evaluation
# Units
%fmr Type 1P Pad
Bld #: 9370
Size
Secondary V 240,120
Date: ;'k,!obar 21, 2010
NL Loss Cost
3 <K, Stock Of T120130
FL Loss Cost
1.50
Specified
Impedance',
1.07 (See Impedance Requirements
Table in Specification)
Includes Winding's Stray
Losses
Losses 8 Losses
associated
Base Bid
Rark Based on
Rank Based on
Base Bid
Guar No
Guar Total Associated wth Auxiliary
Winding's with Auxiliary
Impedance
Extended Cost NL Loss' NL FL Loss'
FL
Bid (1 I. best
Evaluated bid (1
Stppaer
Manufacturer $ / Each DaVW ks
Load Loss Guar Full Load Loss
Impedance Meet Specs? Escalation Load Loss Devices (Yes / No)
Stray Lasses Devices
Variance Evaluated Bid (Total $) Loss
Cost Loss Cost
choice)
Is best choice)
Irby
Eaton Cooper Powe S 1,583.GO 12
64 225
1.86 yes y�.;
289 yes
6.82 0
-5.34% $
2,171.00 $ 47,517.00 $
249.60 $
337.50
3 2
Wesco
ABB S 1,706.25 8 - 10 Weeks
60 236
1.25 Yes Yes
296 Yes
1 3
-0.761io $
2,294.25 $ 51,187.50 $
234.00 $
354.00
4 4
Western Uniled
Central Moloney $ 1.505.00 12
62 277
1.80 Yes Isrot
339 Yes
8 0
-8.40°; $
2,162.30 $ 45,150.00 $
241.80 $
415.50
2 1
Western Uniled
Howard lndusides $ 1,499.00 6-8 wks ARO
64 297
1.90 Yes No
361 Yes
o 0
-331% $
2,194.10 $ 44,970.00 $
249.60 $
445.50
1 3
0
-100.00% $
- $ - $
- $
-
#N/A
-
Notes:
1. It appears that Cooper meets our specifications but some clarifications have been sent regarding multiple sections in our specification. They state they will rot provide an internal marking for fluid levels at 25 deg C. A word document has been drafted and sent to gather/provide information iromdor them.
2. it appears that ABB meets our specification.
3. Central Maloney appears to meet our specifications.
4. Howard Industries states that they do not meet our spec due to the height of design needing to be 35' rather than 32', which is our current max height. We are willing to make an exception to this height requirement since the height still falls into the general height requireents specified in C57.12.38.
Based on the ranking of the evaluated bids. Central Moloney care of Western United is the lowest evaluated responsible bidder and should be awarded Bid $370,
IEEE C57.12.00, Section 9.2 Tolerancesfor impedance
The tolerances for impedance shall be as follows:
a) The impedance of a two -winding transformer with an impedance voltage greater than 2.5%shall have a tolerance of ±7.5%of the specified value, and those with an impedance voltage of 2.5% or
less shall have a tolerance of±10% of the specified value.
Differences of impedance between duplicate two -winding transformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed 7.5%of the
specified value.
b) The impedance of a transformer having three or more windings, or having zigzag windings, shall have a tolerance of±10%of the specified value.
Differences of impedance between duplicate three -winding or zigzag transformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed
10% of the specified value.
c) The impedance of an autotransformer shall have a tolerance of ±10%of the specified value. Differences of impedance between duplicate autotramformers, when two or more units of a given
rating are produced by one manufacturer at the same time, shall not exceed 10%of the specified value.
d) Transformers shall be considered suitable for operation in parallel when reactances come within the limitations of the preceding paragraphs, provided that turns ratios and other controlling
characteristics are suitable for such operation.