HomeMy WebLinkAboutBid Tally -8370 TRANSFORMERS 25KVA & 100 KVA SINGLE PHASE PAD-MOUNTED1 Phase Padmounted Transformer Bid Evaluation # Units %fmr Type 1P Pad Bid if: Size IDb kVA SecondaryV 240,120 Date: NL Loss Cost $ 3 90 Stock # T120170 FL Loss Cost $ 1.so Specified Impedance % 2.1 r (See Impedance Requirements Table in Specification) Includes Winding's Sbay Losses Losses 8 Losses sndated Base Bid Rank Based on Rank Bassd on Base Bid Guar No Guar Total Associated oath A-hary Winding's with Aumliary Impedance Extended Cost NL Loss' NL FL Loss' FL Bid (1 is best Evaluated bid (t Supplier Manufacturer $ / Each DeVWks Load Loss Guar Fue Load Loss Impedance Meet Specs? Escalation Load Loss Devices (Yes / No) Sbay Losses Devices Variance Evaluated Bic) (Total $) Loss Cost Loss Cost choice) is best choice) Wesco ABB S 2,611.50 8 - 10 Weeks 152 863 2.15 Yes Not 1015 Yes 11 8 -OA2'0 $ 4,498.80 $ 39,172.50 $ 592.80 $ 1,294.50 4 3 Western United Central Moloney $ 2,110.00 12 161 921 2.04 Yes is not 1082 Yes 26 0 5.99°m $ 4,119.40 $ 31,650.00 $ 627.90 $ 1,381.50 1 1 Irby Eaton Cooper Powe$ 2.346.60 12 ISO 928 208 Yes Yes 1078 Yes 38,63 0 A, 15%$ 4,323.60 $ 35,199.00 $ 585.00 $ 1.392.00 2 2 Western United Howanl Industries $ 2,566.00 8-10 WKS ARC 196 789 2.10 Yes No 985 YES 32 0 -3.23% $ 4,513.90 $ 38,490.00 $ 764.40 $ 1,183.50 3 4 0 -100.00% $ - $ - $ - $ - NN/A - Notes: 1. it appears that ABB meets our specification. 2. Central Maloney does not provide any design documents with bid proposal but they appear to meet our specification 3, it appears that Cooper meets our specifications but some clarifications have been sent regarding multiple sections in our specification. They state they will not provide an internal marling for fluid levels at 25 deg C. A word document has been drafted and sent to gather/provide information irom/lor them. 4. From the bid documents, it appears that Howard Industries' footprint is 7' longer than our specification states however it will still fit on our 43' x 37' surface area. Also, Howard's u is are 3' taller than our specification allows however they still fall within C57.12.38's height limitations which is what we base our uit's dieter Based on the ranking of the evaluated bids, Central Moloney care of Western United is the lowest evaluated responsible bidder and should be awarded Bid 8370. IEEE C57.12.DO, Section 9.2 Tolerances for impedance The tolerances for impedance shall be as follows: a) The impedance of a two -winding transformer with an impedance voltage greater than 2.5%shall have a tolerance of±7.5%of the specified value, and those with an impedance voltage of 2.5% or less shall have a tolerance of±10% of the specified value. Differences of impedance between duplicate two -winding transformers, when two or mote units of a given rating are produced by one manufacturer at the same time, shall not exceed 7.5% of the specified value. b) The impedance of a transformer having three or more windings, or having zigzag windings, shall have a tolerance of ±10%of the specified value. Differences of impedance between duplicate three -winding or zigzag transformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed 10%of the specified value. c) The impedance of an autotransformer shall have a tolerance of±10% of the specified value. Differences of impedance between duplicate autotransformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed 10%of the specified value. d) Transformers shall be considered suitable for operation in parallel when reactances come within the limitations of the preceding paragraphs, provided that turns ratios and other controlling characteristics are suitable for such operation. No Text 1 Phase Padmounted Transformer Bid Evaluation # Units %fmr Type 1P Pad Bld #: 9370 Size Secondary V 240,120 Date: ;'k,!obar 21, 2010 NL Loss Cost 3 <K, Stock Of T120130 FL Loss Cost 1.50 Specified Impedance', 1.07 (See Impedance Requirements Table in Specification) Includes Winding's Stray Losses Losses 8 Losses associated Base Bid Rark Based on Rank Based on Base Bid Guar No Guar Total Associated wth Auxiliary Winding's with Auxiliary Impedance Extended Cost NL Loss' NL FL Loss' FL Bid (1 I. best Evaluated bid (1 Stppaer Manufacturer $ / Each DaVW ks Load Loss Guar Full Load Loss Impedance Meet Specs? Escalation Load Loss Devices (Yes / No) Stray Lasses Devices Variance Evaluated Bid (Total $) Loss Cost Loss Cost choice) Is best choice) Irby Eaton Cooper Powe S 1,583.GO 12 64 225 1.86 yes y�.; 289 yes 6.82 0 -5.34% $ 2,171.00 $ 47,517.00 $ 249.60 $ 337.50 3 2 Wesco ABB S 1,706.25 8 - 10 Weeks 60 236 1.25 Yes Yes 296 Yes 1 3 -0.761io $ 2,294.25 $ 51,187.50 $ 234.00 $ 354.00 4 4 Western Uniled Central Moloney $ 1.505.00 12 62 277 1.80 Yes Isrot 339 Yes 8 0 -8.40°; $ 2,162.30 $ 45,150.00 $ 241.80 $ 415.50 2 1 Western Uniled Howard lndusides $ 1,499.00 6-8 wks ARO 64 297 1.90 Yes No 361 Yes o 0 -331% $ 2,194.10 $ 44,970.00 $ 249.60 $ 445.50 1 3 0 -100.00% $ - $ - $ - $ - #N/A - Notes: 1. It appears that Cooper meets our specifications but some clarifications have been sent regarding multiple sections in our specification. They state they will rot provide an internal marking for fluid levels at 25 deg C. A word document has been drafted and sent to gather/provide information iromdor them. 2. it appears that ABB meets our specification. 3. Central Maloney appears to meet our specifications. 4. Howard Industries states that they do not meet our spec due to the height of design needing to be 35' rather than 32', which is our current max height. We are willing to make an exception to this height requirement since the height still falls into the general height requireents specified in C57.12.38. Based on the ranking of the evaluated bids. Central Moloney care of Western United is the lowest evaluated responsible bidder and should be awarded Bid $370, IEEE C57.12.00, Section 9.2 Tolerancesfor impedance The tolerances for impedance shall be as follows: a) The impedance of a two -winding transformer with an impedance voltage greater than 2.5%shall have a tolerance of ±7.5%of the specified value, and those with an impedance voltage of 2.5% or less shall have a tolerance of±10% of the specified value. Differences of impedance between duplicate two -winding transformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed 7.5%of the specified value. b) The impedance of a transformer having three or more windings, or having zigzag windings, shall have a tolerance of±10%of the specified value. Differences of impedance between duplicate three -winding or zigzag transformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed 10% of the specified value. c) The impedance of an autotransformer shall have a tolerance of ±10%of the specified value. Differences of impedance between duplicate autotramformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed 10%of the specified value. d) Transformers shall be considered suitable for operation in parallel when reactances come within the limitations of the preceding paragraphs, provided that turns ratios and other controlling characteristics are suitable for such operation.