Loading...
HomeMy WebLinkAboutRESPONSE - BID - 8346 TRANSFORMERS 300 KVA THREE PHASE PAD-MOUNTEDEXHIBIT A BID ACKNOWLEDGEMENT Contractor hereby acknowledges receipt of the City of Fort Collins Utilities' Request for Bids for the Transformers and acknowledges that it has read and agrees to be fully bound by all of the terms, conditions and other provisions set forth in the Bid. Additionally, the Contractor hereby makes the following representations to Utilities: a. All of the statements and representations made in this bid are true to the best of the Contractor's knowledge and belief. b. The Contractor has obtained all necessary authorizations and approvals that will enable the Contractor to commit to the terms provided in this bid submittal. c. This bid submittal is a firm and binding offer, for a period of 45 days from the date hereof. I further agree that the method of award is acceptable to my company. I acknowledge receipt of _ addenda. Contractor Firm Name: \ � tA" \S a Physical Address: \ -Qcy,�" Remit to Address: Sp --Mg!.. Phone: a(D - S $D - 77 0 LA i _ Authorized Agent of Firm Name: Signature of Authorized Agent: Primary Contact for Project: S�e (` Mac, Title:_S�,Q � S Email Address: Phone: --W)b ;9M- -70L4I Cell Phone: CC ,'o. ar Systems USA inc T E Q s ,A L SP]EC5 T :P,t a5 fiv8. Y.rS','rjlt r. IJ Quantity: 1.1 Three Phase Pad -Mount Transfornier(s) I.VA Rating: 344 IWA Model #: Mincral Oil Immersed Cooling Class: ONAN MIA-1;Altitudc consicicra:itnn hr'egaency-: (10 H% 65 °(' 1'rint::rt 1 ult.t�r: ; 3?(t!1 Gtdy: `020 vna+ ticcundxry Valtilge: .OtiY. ; 20 volt, l'1'IIII'31'1 fill. Rating: ` )5 kV St-concha-Y It'll. Rali,tg: O kv flb 11 inding 1•Iutl:-llrnninum I-V Winding AM: .aluminum High Voltage Taps: B Taps - Two 2.5%Taps below Nominal ond'fwo 2-5 /r.; Taps above Nominal No Load Loss. 598 Watts Load Loss: 2083 Watts rotai Loss: 2681 Watts Impedance: 2.47 % Tank Enclosure: _ Welded Cover w/(I) Handhole(s) - IOx16 Cabinet Depth: 19 Inches, Pentahead Security Bolts Sicel I-IV-I,V Barrier 1.oi-p Fix-i +. Li wn I1imen,ion,, E1,'atl I•rra( l'rin,:ul 1c;+nirrsiin:,:•: �leli� 5tx: rnlar•. I'.,rr in:n :t,. l;.Luc, Pn>':in+,� .:,i"hr,:ad-on -1 flolo Vva iiimml H Snadv.. Srnie Sit-mo•t --- f I amm! t ' SA* ti)- Plastic Drz. i hicld { ). l'RC LF t('lit Pressure: Relief Val:c IFO. Drain va) c w•/Sampler Liquid Temperature Gauge 1" Upper Filter Press and FillinJ Plug Upper Filter Press and Pilling Plug (or Cap) 1" Switching: FIOXO Removable Link Paint Color: Dl%SI-.RT TAN (NIUN'SELL I OYR6.4/3/0). Coal Tar Over Powder. -1„it-d :!! of,rl,ftl:tr, tv fh the (alc.t alviicablt ANSI standards uni.ss oulct•:rise specified hi' the :oston,cr, ',llipliken!: 14 w I' Printed by PSUS-Sally Kleekamp on 9/13/3016 CG Power Systems USA Inc TERMS L. CONDITIONS OF Registered Office d Plant: SALE One Pauwels Drive, Washington, Missouri 630�,0, USA T; +1 636 239 9300 F: +1 636 239 9398 W: www.cgglobal.com Commercial Terms alternative delivery is required, freight price adders may apply. Purchaser should advise at or before time of order of any special requirements. 1. COMMERCIAL TERMS CG Power Systems USA Inc (herein referred to as "CG") is an ISO certified company. Our standard Terms and Conditions of Sale apply unless otherwise indicated. CG assumes no obligations or liabilities beyond those sppecifiod i.i th(: CG document enti'lect ''Form,,s & Coy all'.1 ns of Sale Unless otherwise indicated in this proposal, standard delivery terms are F.O.B. CG Factory, freight prepaid and allowed. Freight is included in the proposed equipment price with Purchaser assuming all risk of loss and damage in transit and liable for cost, such as demurrage or detention, after the purchased equipment has left our loading docks or facility. 2. QUOTATION NOTES Our proposal is valid for the equipment specifically described in the attached CG Technical Specs. Adding of any reouirrr design featuros not included in our Technical Sper,.s at tirne of proposal may result in revisions to the proposed price, delivery time, or any other particulars related to the herewith submitted proposal. This proposal includes standard factory testing. These tests are standard routine test as defined by the latest ANSI standards. Certified test reports can be provided at no additional charge upon indication at time of purchase order placement. Price adders will be incurred per schedule for items such as witness testing, sraeciai tests, ir.snectians, etc. The proposed equipment is based on application at an altitude of 3,300 ft and below unless specifically noted in the design. For equipment rated at standard altitude and used in applications above this elevation, the transformer must be de -rated In accordance with applicable ANSI standards. 3. SHIPMENT NOTES Shipment will be made according to quoted lead times after complete order information is received by the factory, inclusive of approval/record type drawings when requestoo at time or order. Should standaro apprcvrrl diawit,ps be req-..sired they can be mailkad 2-3 weeks ARO Ai, prices are for shipments arriwng by truck at Purcimser's site, Mon -Fri, 8AM-5PM. If 4. PROPOSAL CLARIFICATIONS All Transformers are shipped with our standard Operations and Maintenance manual, unless otherwise indicated. Impedance (%1z no��iinail andi'or losses quoted are subject to the applicable ANSI tolerances. Average sound level shall not exceed NEMA standards. Rubber Goods such as primary elbow connectors, portable insulated standoff bushings, deadend caps/plugs, as well as items such as hotsticks, hooksticks, padlocks, and special tools unless specified in the BOM, are Purchaser supplied. For Delta conficlured transformers, core design shall be 3-logged stacked and not 5-legged wound type. Annealing for our stacked designs is "not required". 5. TESTING Pricing includes CG "standard" factory tests below: -Applied Voltage on Secondary -Applied Voltage on Primary (Delta connected only) -Induced Voltage -No Load Loss and Excitation Current -Load Losses and Impedance Voltage -Winding Resistance Ratio -Phase Rela'ion -Sobn'19sion of 10011<o of ail production to production line impulse testing Accuracy of test equipment is within +/- 3% traceable to national Bureau of Standards and calibrated annually. Additional testing beyond those listed will incur additional fees per schedule. ONE PAUWELS DRIVE WASHINGTON, MO 63090 PHONE: 636.239.9300 FAX: 636.239.9398 n: '^ CG Power Systems USA Inc Registered Office & Plant: One Pauwels Drive, Washington, Missouri 63090, USA T: +1 636 239 9300 F: +1 636 239 9398 W: taw v.cggiobal.corn 6, CANCELLATION SCHEDULE If an order cancellation occurs, penalties will apply per CG Cancellation Schedule. TERMS & CONDITIONS OR SALE STATUS SALES PRICE Order Acknowledged 5% Scheduled • Order Scheduled 10% Fn incerin,, _ —! • f.ha��in ,s Esstied i Pruchtclion Control '— • f'in;ti \1;u': Cl:il (}rt{:'t'c`:.I _._..----- �---....._- 0 5,'heduir, I..urd'k, PhIll" Transformer Produt:(ion 1517 .D"ir----•-1 • Tank Slimed — --- 5()rt • Core Started --- 65% —� • CoiI Started 75 % • Advanced Assembled Parts (Core & Coils) 100% • Oven 100% • Tanked 100% • Tested 100% _ + Asscmifl% 100% _Final 1-11111rpe(J ONE PAUWELS DRIVE WASHINGTON, MO 63090 PHONE: 636,239.9300 FAX: 636.239.9398 GG Power Systems USA Inc. Washington, Missouri (USA) 'Rt?Ut* Tests Dptailed At;St'IEEE C57.12.90 Remarks I Acceptance Description of Tests Section Criteria Winding Resistance measurements Section 5 Of all windin on t':o rated voyage tap and at the tap extremes Total Loss within tolerance Ratio test dnd phase relation � �ieenon o, 7 On the rated vottage connectioc and on all tap connections O.5 /o of Calculated Ratio No-load and excitation current Section 8 _ _ At 100% and 1101 voltage and at rated frequency _ .. 0% of Guaranteed NLL At rated curront ar.J frequency on the rated voltage connection arc at Impedance voltage and load loss Section 9 the tap extremes .6 c of Guaranteed Total Losses ±7.5 of Guaranteed %iZ Low Prenuenev Tests Section 10.6 On rated voilaoe connection of primary and secondary windings. — Applic 1 voltage HV Winding %34, ': tiaye: See IEEE C57.12.90 _ LV Winding 1'est voltage: — Induced voltage Section 10.7 On the rated voltage connection of primary & secondary windings. See IEEE C57.12.90 (Clara f jar, N,4, Transformer Test) AC Level: 2 linos rrtec voltage for 7200 cycles. Quality Cc,arol ;erd. One r,)duced wave followed by one full wavy: nn LightnineImpulse Test Section 10.4 HV phase terminals only. Chopped wave and switching impulse See IEEE C57.12.90 are not included. Auxiliary 'germ Dielectric Test Dielectric m ,q-^a i r t ;i7rJV7L' to ground — Bee IEEE 057.12.90 Bushing Current Transformers Dielectric .^ ogga, r,f 250OVDC to ground :0.5°/ of Calculated Ratio Check of polarity and ratio of bushing current transformers. Standai a Leak test of Fully Assembled Transtorrn�-r Section 8.2 at C57.12.00 5 psig of dry a:r (14 ai ambient temperature) for 24 hours No Leaks _ _ See Remarks Mechanical inspection Conformance to specs. standards and drawings. Check of layout d,rrensions. clearances. etc. Check of namepiare data. Functional test of all accessories and auxiliary devices Page 1 of 1 CG Power Systems USA Inc Registered Office & Plant: One Paumis Drive, Washington. Missouri 63090, USA 1 +1 636 239 9300 F: +1 636 239 9395 W. a wnv.cgglobat.com Smart solutions. Strong relationships. TEST PRICE SCHEDULE — 2500 kVA and Smaller Following list prices shall be respected for {est. in Accordance to the latest ANSI si:andard< <:t time of quotation: Description Unit Size t)nit: price each Remarks Full impulse test 2500 kVA and smaller $900 Heat Run Test, OA 1000 kVA and smaller $2400 rating or one rating only* Heat Run Test, 0A 1500 kVA up to and $2700 rating or one rating including 2500 kVA Heat Run tns:., each 2500 kVA and i,maller ~ Sound level Fast, one 2500 kVA and smaller + $600 � rating" only—__— Sound level test, each an _----- --- 2500 WA d smaller $400y additional ratin Insulation P/F test (not 2500 kVA and smaller $200 doble test Oil Quality test 2500 kVA and smaller $200 Outside Lab Per sample Oil DGA test 2500 kVA and smaller $400 Outside Lab ' Per sample 5'tprt Circuit test 2500 kVA and smaller TO BE REQUESTED Outside Lab Vyitness tes!incl ?500 kVA and smaller t �.?50 per day l To be scheduled in i l 1 advance * Witness Testing or Temperature Rise Testing will add 1-2 weeks to shipment schedule. The coaLolled copy of this document is located on the PSUS Intranet Site. This copy was printed on 3,26l15 at 10:21 AM AVANTtIA C,R011P nnwPANY CG 11wser }t ;tvnh t.'I .A ine r;.iU'+a). '. SA3 r 4,a, Smart solutions. Strong relationships. WARRANTY TERMS WARRANTY: Company warrants to Purchaser that the equipment to be delivered to Purchaser will be free from defects in material and workmansh!p when t.ised under groper and normal use for a period of 12 months after the equipment is put into service. Not to exceed 18 months from the date the equipment is delivered (whether by sale, lease or rental). Organic insulation materials are sold with the express understanding that their life and fitness for purpose are indeterminate and largely depend on application and operating circumstances and continuing maintenance, Should any failure :a conform to the above (or to any additiolin! ,A,!!1rT,,anty contained in the special conditions of sale set forth in the applicable r)rod,.,ct-!`no ;rice szh -r�,tl ippear .vith within one (1) year after me date of shipment by Company, the Company agrees, upon prompt notification thereof and conformation that the equipment has been stored, installed, operated and maintained in accordance with recommendations of the Company and standard industry practice, to correct the nonconformity at Company's option either by repairing any defective part or parts or by making available at i,'ompany's plant a repaired or replacement par',. The, liat)ility of Cor pany to Purchaser arising out of ti-le supplying of said ­:quipment or its ..use, whother on warranty, contract or negligence, shall not in any event exceed the cost of correcting defects in the equipment as herein provided, and upon the expiration of said one (1) year, all such liability shall terminate. The foregoing shall constitute the sole remedy of the Purchaser and the sole liability of Company. The Warranty does not and shall not include reirrbursement for the expenses which may be incurred by Purchaser. Before any material is returned, Purchaser must contact Company, as outlined under Returned Goods. No warranty is made with respect to equipment not manufactured by Company, such being subject only to warranties made by their respective manufacturers. Company shall in no event be responsible or liable for modifications, alterations, misapplication or repairs made to its products or equipment by Purchaser or others, or for damage caused thereto by negligence, accident, overloadi; ig or improper use by Purchaser or others. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN, ORAL OR IMPLIED (INCLUDING ANY WARRANTY ON MERCHANTABILITY OR FITNESS FOR PURPOSE). THE ONLY WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE ARE THOSE EXPRESSED ABOVE AND THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILIT` OR FITNESS FOR PURPOSE. One Pauwels Drive, Washington MO 63090 PH 636-239-9300, FAX 636-239-9398 The controlled copy of this document is located on the PSUS Intranet Site. This copy was printed on 1/15/2015 at 9:31 AM. CG Power Systems USA Inc One Pauwels Drive, Washington, Missouri 63090, USA T: + 1 636 239 9300 F: + 1 636 239 9398 W: www.ceelobal.com CANCELLAT101-NI SCHEDULE STATUS SALES PRICK Order Acknowledged 5%v Scheduled • Order Scheduled 10% Engineering__ _ • Drattinp Issued _ 15% 1'rcxlrlclu�r Control • I:in:.l; \iatrrial 0alercll t 3'::utsti•.rtu�•r 1'rcultl•:tiun _ _ _• T.lnk Started — -- 'iO4-r — Core Started 65'% • _ Coil Started 75% • Advanced Assembled Parts 100% (Core &. Coils) • Oven 100% • Tanked 100% • 100% �� •- _Tested _ 1' na! Assrmhl� 011114, Sally Kleekamp Account Specialist Miguel Osuna Product Sales Manager The controlled copy of this document is located on the SharePoint Intranet Site. '1'Iti, coley was printed on 8117l2016 at 10:48 AM PSUS-Sally Kleckanip. C41L w0i Smart solutions, Strong relationships. 0 AVAPITHA CROUP COMPANY 8346 TRANSFORMERS, 300KVA BID SCHEDULE WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR 8346 TRANSFORMERS, 300KVA, THREE PHASE, PAD -MOUNTED PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS. QUANTITY: DESCRIPTION: 11 ea. T3000030 TRANSFORMER, 300 kVA PAD -MOUNTED COMPARTMENTAL TYPE, THREE PHASE DISTRIBUTION WITH SEPARABLE INSULATED LOAD BREAK HIGH VOLTAGE CONNECTORS. HIGH VOLTAGE RATING: 13200 GRDY/7620. LOW VOLTAGE RATING: 208Y/120. SERIAL NUMBER 030 TO BE IN ACCORDANCE WITH SPECIFICATION #368-300-030, REVISION QQ. Please complete the Excel spreadsheet issued separately for bid submittal. The spreadsheet MUST be submitted in Excel format only. Failure to submit in the format requested may cause the submittal to be deemed incomplete and may be subject to rejection. IF YOU ELECT TO PASSWORD PROTECT YOUR BID, PLEASE NOTE THAT PASSWORD IN A SEPARATE EMAIL TO puurchasing(a-)fcgov.com at the time of bid submittal. "Any surcharges or additional costs shall be noted & included in bid submittal. For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid. Awards from this bid will be based primarily on the evaluated bid price. Delivery lead times, escalation and exceptions taken will also be considered. The City of Fort Collins reserves the right to split the bid award in whatever percentages are most advantageous to the City. Future orders of 300KVA THREE PHASE, PAD -MOUNTED may be authorized, at the option of the City, from this bid for a period of five years after bid closing date. Satisfactory pricing, losses and delivery are required for future orders based on this bid. BID 8346 Page 3 of 30 Fort Collins Utilities Transformer Bid Loss Data Sheet FCU Stock # T3000030 # Units Bid #: Preparer Name : Name Size 300kVA Date: 13Sep Preparer Contact Num: Number NIL Loss Cost $ 3.91 FL Loss Cost $ 2.K Includes Winding's Stray Losses 8 Losses Escalation Losses Associated associated Base Bid Base Bid $ / Guar No Load Guar Full Load Most Specs? (is / is not) Guar Total with Auxiliary Winding's with Auxiliary NIL Loss' NIL FL Loss' FL Evaluated Extended Cost supplier MIr / Mfr# Each DeVWks Loss Loss Impedance (Yes / No) a factor Load Loss Devices (Yes / No) Stray Losses Devices Loss Cost Loss Cost Bid (Total $) Supplier 1 Mfg 1 S 8,328,00 14 - 16 Weeks 698 2083 2.47 Yes Is Not 2681 Yes 0 0 $ 2,332.20 $ 4.790.90 $ 15,461.10 $ 91,608.00 Supplier 2 Mir 2 $ - - 0 0 0.00 - - 0 - 0 0 $ - $ - $ - $ - Supplier 3 Mfr 3 S - - 0 0 0.00 - - 0 - 0 0 $ - $ - $ - $ - 1) No load losses 2) Full load losses — it shall be clearly stated whether this number includes the winding's expected stray losses and losses associated with auxiliary devices 3) Winding's expected stray losses related to quoted transformer design 4) Losses associated with auxiliary devices such as fuses, breakers, switches, etc. quoted loss values shall be corrected to a reference temperature of 85'C. Quotations submitted during the bid process without the required losses information shall be deemed unresponsive and are subject rejection by the City of Fort Collins. Fill out the information in the cells with blue text. Save the file using your company name and the bid number and e-mail it to: purchasing@fcgov.com (Example: TransformerSales_Bid_58.xls) I o protect this file, take the following steps: 1) Select Tools, Options 2) Select Security Tab 3) Type your password in the "Password to Open" field. 4) Re-enter your password to confirm it. Important! Please remember to include this password in the bid information that will be sealed in the envelope that will be unsealed at Bid Opening. This will secure your data until the time of the bid opening. 5) Save the file and e-mail it to: purchasing@fcgov.com HO D )OINDUST IE SILICON WESTERN UNITED ELEC SPY 100 BROMLEY BUSINESS PKW BRIGHTON, CO 80603 Item ITEM 1 11 Howard Industries. Inc. Utility Transformer Division P.O. Box 1588 Laurel. MS 39441-1588 Phone: 601 425 3151 Fax: 601 6498090 FOB: DESTINATION PRICING:FIRM FOR QUOTED SHIPMENT AGENT: AMERICAN POWER & COMM-WE Description PRODUCT: 3-PHASE PADMOUNT ANSI C57.12.34 DEAD FRONT KVA: 300 KVA HV: 13200GRDY/7620 + GRD 95KV BIL LV: 208Y/120 30KV BIB• TAPS: (2) 2-1/2 ABOVE & BELOW LOSSES: NO LOAD = 534, LOAD = 2430, TOTAL = 2964 IMPED = 2.6 OIL TYPE: MINERAL QUOTED PER CUSTOMER SPEC 368-300 DATED 7/6/16 EVALAUTED: NO LOAD = 3.90 LOD = 2.30 THREE PHASE PADMOUNT, DEAD FRONT, LOOP FEED. 2016 DOE COMPLIANT VALIDITY: 30 DAYS 'PERMS: NET 30 DAYS INQUIRY: CITY OF FORT COLLINS 8346 SINGLE VOLTAGE ORDERS REQUIRING APPROVAL DRAWINGS: LEADTIMES QUOTED ASSUME THAT APPROVAL DRAWINGS WILL BE SIGNED AND RETURNED TO HOWARD INDUSTRIES WITHIN TWO WEEKS OF RECEIPT OF SAID DRAWING. SHOULD THE PROCESS REQUIRE ANY ADDITIONAL TIME BEYOND THESE TWO WEEKS, THAT ADDITIONAL TIME WILL BE ADDED TO THE QUOTED LEADTIME. TRANSFORMERS ON THIS QUOTATION ARE DESIGNED TO COMPLY WITH DOE EFFICIENCY REQUIREMENTS EFFECTIVE FOR COVERED TRANSFORMERS COMPLETING MANUFACTURE BEGINNING JANUARY 1, 2016. CUSTONI�ER COFY PAGE NO: 1 Unit Price '3, -71�)_ Shiptnet AR ,g 06-08 WKS UNCONTROLLED COPY LAST PAGE SUBMITTED BY LARETIAA HILL UNLESS VIEWED ON A PC FROM THE 'QCShars on Howardpdc Dr.,,, DESCRIPTION LV BUSHING & 4-HOLE SPADE LV SPADE SUPPORT - 1/2-13 GROUND PAD HV BUSH DF WELL LOADBREAK PARKING STAND NP ON DOOR, SERIAL ON TANK TANK HANDHOLE & SECURITY COVER LIFTING LUGS JACKING PROVISIONS 1/2-13 GROUND PAD 1 IN DRAIN VALVE AND SAMPLER PADLOCKABLE DOOR HANDLE 3 PT LATCH PENTA SEC BOLT 12 IN REMOVABLE SILL METAL LV-HV BARRIER CUP ON DRIP SHIELD BAYONET FUSE HOLDER_ iFD NON-RESETTABLE DEVICE DIAL THERM W/MAX POINTER 2" MAGNETIC LL GAUGE OIL LEVEL PLUG TAP CHANGER HANDLE 1" UPPER FILTER PRESS CONN PROVISION FOR PRES VAC GAUGE SPECIAL NOTES' BAY-O-NET FUSE CURRENT LIMITING FUSE 'AT NO CC. 745 NOT FOR CONSTRUCTION I� 25 -" 91806311S,6M, 16, 0,FO8 ,169, 5, 45 I HOWARD U INDUSTRIES INC. LAUREL, MISS, USA 39440 THREE PHASE PAD DISTRIBUTION TRANSFORMERS CUSTOMER : FORT COLLINS, CO. SPEC. 368- 300 DA i cD n7 /nF, /1 Fi LOW VOLTAGE 0 APPROX. CORE AND COIL WEIGHT 2147 APPROX. TANK AND ACCESS. WEIGHT 90 GAL. OF ❑IL 2301 APPROX. WEIGHT 1726 APPROX. TOTAL WEIGHT 47R1 DESCRIPTI NOTE: THE WEIGHTS AND DIMENSIONS ARE APPROXIMATE AND SUBJECT TO CHANGE WITHIN THE CUSTOMER SPECIFIED LIMITS. APPROVAL DRAWINGS WITH THE ACTUAL WEIGHTS AND DIMENSIONS WILL BE PROVIDED UPON REQUEST AFTER RECEIPT OF ORDER. NOTE: (1) DIMENSIONS IN INCHES (2) WEIGHTS IN POUNDS 0 N 505129, 616871,2, 514.2, 2379 59000000.210 HL8659001 i NO. TRANSFORMERHOWARDQINDUSTRIES LAUREL MS 39440 DOE COMPLIANT READ INSTRUCTION HI 105 BEFORE OPERATING MFG KVA 3 0 0 BIL HV 9 5 LV 3 OKV 2. 6%dMP HV 132000RDY/7620 Lv208Y/120 AMPS 833 LB TANK 908 C&C 21 4 7 OIL II 230 6GAL TOTAL 4781 LB I I CONT 65 'C R[SE CLASS ONAN 60HZ --- TANK DESIGNED FOR +7 PSIG F1 CLF PARTIAL RANGE r � F2 BAYONET FUSE CONTAINS NO DETECTABLE LEVEL OF PCB (LESS( 0 LESS( O 0 r ) ) l THAN 2 PPM) AT THE 71ME OF MANUFACTURE. J 7 7 F2 VOLTAGE POS AMPS o F1 13860 vA 12.5C 0NV LV 13530 2/B 12.80 ,� x 13200 3/C 13.12 AL AL Ho xo co 12870 4/I1 13.46 o H1„ 3p Ox1x2x3 12540 i 13.81 Hl H xi x 0 a SER. NO_ BAR CODE CAT. NO. BAR CODE SER. ND, HOWARD [MINDUSTRIES INC. LAUREL, MISS. USA 39440 MFG. OF DISTRIBUTION TRANSFORMERS NAME: LASER NAME PLATE cc 857 DESCR: LF/TP/2FUSE/ Y—Y ID 3VHLO136 DWG: HL8659001 REV DATE REVISION BY tAPP SCAM 1.00C 1 DWG BY CHK BY I DATE9/07/16 strong Date: 09/ 13/2016 Customer: WESTERN UNITED ELEC SUP CORP 100 BROMLEY BUSINESS PARKWAY BRI(IHTON, Colorado 80603 Rel*Crt.a«: (TI"1' '-)i' I -Wl C( .1-INS. ('O Ve are pic;ased to present our gUotattot) for three phase: transformers with the acLCSsOrieS according to the attached bill of material(s). General Conditions: Prices: Firm for the duration of the contract. Validity: From 09/ 14/2016 to 10/ 16/2016 Taxes: Federal, state, local or any other taxes are excluded. 1're441it: 1`013 best.. i`rt allowed on PPD f.1vinfAll: 0 Dav> Net Z` at'1'NIICti': tit::i-idard. i 2 month; from the date of installation. but not to cxCeed 18 n"•flth:, i' t tt the da"k, of ;Itil7t7;�:tt. r',.n; t! ,i::i ctiittett>ic'rt;. u.lic ; otherwise specified are for i-i'dication only, and ,ire not binding. This quotation' is .�i.djcvl it, CCi Pc ver System USA Ternis and Conditions of Sale, which are available at www.cgglob<tl.us. Any deviation from the attached bill of matcrial(s), before or after receipt of order, may affect price and delivery. The quoted ship weeks will go into effect after all outstanding technical matters have been resolved. Ship weeks are based on plant loading at time of quotation. Please verify ship weeks when placing an order. Please reference our quotation number on all purchase orders and C01'reihonilence. «'c Nvill pleased to prek+,ilo yOU with any additional information that is required. Plank- you for your intiuirti. :ind %,v lot4 lOrw:ird to workinIg ,pith you iit die ftnurc. Sincereiv. CG Power Systems USA Iric Sally Klecykamp account Specialist ,.'Bill`- JGIC' Miguel Osuna Product Sales Manager DistribUtion Tranid'ormers Vrl:. aid 'eC:.C'. ^.r? to pioise rfre: . j GG .> P�,va,x, :'ctwy ...,rt.ii• on ws •r ,re W 'vY .Y.Cg:7io;.ai JDtn to wldo-r5lend antl fzn1!1i3rr8e yJ4'Self with t;Gs Pnvn--.y PoIICY iavd.3r(t3 A3 l)USir:u>., partners vJh r.•spect 1c shafina of perscnel 7ata. AVA N T H A STar1 !rnaiips. sc:a'ions. 34sng reir.! Dat?C: t19; 13 2016 Customer: WESTERN UNITED ELEC SUP CORP 100 BROMLEY BUSINESS PARKWAY BRIGHTON, Colorado 80603 LTSA (11to(Atiou i orntl'ews' hm; till- 30 i1lys and escal;itinns do not apply. 3.2.2.7. i. NANIEPi_ATE IS IN LOW %:'Ol_TAGE C'ONIPAK' N4ENT' , 6.2.2.9. TANK COVER IS WELDED, WITH 10"x16" HANDHOLE. Test Reports will be sent with Invoice, rather than at time os shipment. Plou-,e :c attached CG Pov,er Svstems Standard List of Routine Tests that are included in our P!"c!'r 1"or additional testing; if required. our Warranty Terms and ilat• Y'•C t:'tttn;& to (..{t Po%%er without oi-1,r lkriaen r' ppi—mat froitl CC; �.l;lat J1i:Ct11. C G llowcr cannot give delivery dates, only ctirrvnt lead tirrics in number of weeks after receipt of order. These lead times are subject to change based on production availability. Due to the volatility of the raw materials market, strict interpretation of our 30 day quotation validation period must be adhered to. If your quote has expired, please consult your Account Speciatist'Product Engineer for a quotation update. ACCl.irt!tt.• ;!Ild 0-Moiled ti'lip to address and contact information is required at time of purchase order it, .issiirc correct shipping and handling. Crltur-Al 'on 1101.1) ii)r %PPRO\•'AU yin(! :-.Xu I rcic: skA within :?;i ___ (3't weeks altlet' i-cct'iViigl tilCtur) approval t1'pe drawings arc subiert it) price lricrenscs at tke !Lmi: of release. It appi-m:ll drawings arc required, quoted lead tlnics begin alter drawings lim'e been approved. Subject al credit atpprmai. 'fe% ore qrr:-s'w•; r; please ref,,- to r p, ,icy Policy avaitable or CG's w , o /'ti ,Ci Customer and Sa fiitr Prix eb-it (�,/,' �. .,a•rst::n�i and fa ii nse •:o;,rs.if ., tr CG's Priva:.r Pu!i:., to%v in,nss T' .. .. aids its UuE !0 '1;af1rg of persor al 'Jac& AVANTH A lk, %:74 C.! 0 Ca.)in.7t HF�iqnt it -,rrij: 2� )08Y' 120 TRANSFORMER OVERKEAD VIEV! 1743 (sa.6,-) Dimensions are preliminary and not for construction.