Loading...
HomeMy WebLinkAboutCORRESPONDENCE - RFP - 7657 ATHLETIC FIELD LIGHTING (4)MUSCO LIGHTING PROPOSAL PREPARED FOR: Rolland Moore Park Lighting Project Fort Collins, CO November 10, 2017 Project #150831 Submitted by: Musco Sports Lighting, LLC 2107 Stewart Road Muscatine, Iowa 52761 Toll Free: 800-756-1205 Fax: 800-374-6402 This information is provided by Musco exclusively for this project. Reproduction or distribution of the enclosed documents or information withough the written permission of Musco Sports Lighting,LLC is prohibited. M-1164-enUS-5 TABLE OF CONTENTS Rolland Moore Park, 150831 Project Submittal: Table of Contents A. LETTER / CHECKLIST B. EQUIPMENT LAYOUT C. ON FIELD LIGHTING DESIGN D. OFF FIELD LIGHTING DESIGN D1. PEDESTRAIN PATH LIGHTING E. ENVIRONMENTAL LIGHT CONTROL DESIGN F. PHOTOMETRIC REPORT G. PERFORMANCE GUARANTEE H. STRUCTURAL INFORMATION I. CONTROLS AND MONITORING J. ELECTRICAL DISTRIBUTION PLANS K. WARRANTY L. PROJECT REFERENCES M. PRODUCT INFORMATION N. DELIVERY TIMEFRAME O. NON COMPLIANCE P. LIFE CYCLE COST SAVINGS Rolland Moore Park, 150831 A. LETTER / CHECKLIST Rolland Moore Park, 150831 Rolland Moore Park, Project # 150831 M-1911-enUS-5 Project Submittal: Bill of Materials Equipment Description 57 Light-Structure System™ Total Light Control™ TLC-LED-1150 luminaires 17 Light-Structure System™ Total Light Control™ TLC-BT-675 luminaires 7 70 Foot galvanized steel poles 3 80 Foot galvanized steel poles 10 Pre-cast concrete foundations (9,500 PSI) with Integrated Grounding  Factory wired and assembled pole top luminaire assemblies  Factory wired electrical component enclosures  Factory built wire harnesses with plug-in connections Controls 2 24 x 72 Controls and Monitoring Cabinet 24 30-amp contactors 4 On-Off-Auto (OOA) switches Warranty  Musco’s Constant 25™ product assurance and warranty program that eliminates 100% maintenance costs for 25 years, including labor, materials, monitoring and guaranteed light levels. B. EQUIPMENT LAYOUT Rolland Moore Park, 150831 EQUIPMENT LAYOUT Not to be reproduced in whole or part without the written consent of Musco ENGINEERED DESIGN By: Daniel Lohman • File #150831r4 • 10-Nov-17 Sports Lighting, LLC. ©1981, 2017 Musco Sports Lighting, LLC. C5 C6 B4 Baseball 3 297'/307'/297' - basepath 90' A3 A5 B5 C7 C8 Baseball 4 297'/307'/297' - basepath 90' B1 A1 SCALE IN FEET 1 : 200 0' 200' 400' Pole locaƟon(s) dimensions are relaƟve to 0,0 reference point(s) Rolland Moore Park Fort Collins,CO EQUIPMENT LAYOUT INCLUDES: · Baseball 3 · Baseball 4 Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE 1 A1 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 5/3* 2 A3, A5 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 3 B1, B4-B5 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 4 C5-C8 70' - 15' C. ON FIELD LIGHTING DESIGN Rolland Moore Park, 150831 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco ENGINEERED DESIGN By: Daniel Lohman • File #150831r4 • 10-Nov-17 Sports Lighting, LLC. ©1981, 2017 Musco Sports Lighting, LLC. C5 C6 B4 38 38 32 38 34 27 21 23 18 17 40 37 33 37 35 30 27 23 19 19 21 35 33 34 32 32 30 24 24 26 22 24 36 33 31 28 28 25 20 20 24 22 18 36 38 30 27 25 23 22 22 20 24 28 34 30 24 22 22 22 23 21 23 23 26 24 19 19 21 17 15 20 18 23 21 23 20 20 23 18 19 18 17 20 24 23 18 23 23 18 17 19 21 22 24 25 16 20 20 16 A3 A5 B5 287' 104' 104' 287' 60' 50' 173' 50' 36' 79' 55' 173' SCALE IN FEET 1 : 100 0' 100' 200' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS 1 A3 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 1 4 1 4 1 A5 70' 10' 25' 80' ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco ENGINEERED DESIGN By: Daniel Lohman • File #150831r4 • 10-Nov-17 Sports Lighting, LLC. ©1981, 2017 Musco Sports Lighting, LLC. C7 C8 34 40 32 33 33 29 27 20 20 20 38 37 38 36 39 32 24 17 19 27 22 28 34 39 35 32 28 24 20 20 22 21 33 35 36 30 25 23 20 20 24 22 15 39 38 32 26 21 19 17 17 19 26 33 29 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco ENGINEERED DESIGN By: Daniel Lohman • File #150831r4 • 10-Nov-17 Sports Lighting, LLC. ©1981, 2017 Musco Sports Lighting, LLC. C5 C6 B4 A3 A5 B5 C7 C8 B1 A1 11 2 12 3 2 2 14 12 9 7 5 3 2 2 1 1 5 9 12 13 14 14 14 12 10 7 5 3 2 1 1 2 2 3 3 4 5 6 5 4 3 9 7 5 2 1 1 1 2 2 4 5 7 8 9 9 9 8 7 13 15 5 4 2 1 1 2 3 4 6 9 12 14 14 14 14 13 12 7 6 4 2 2 3 5 7 11 14 18 19 20 20 20 21 19 14 12 8 5 4 5 8 12 16 20 23 24 26 26 27 27 25 24 24 25 25 23 21 18 13 9 7 9 13 18 22 26 28 29 29 30 30 30 29 28 27 27 28 30 31 30 28 25 22 18 13 11 13 19 24 29 32 34 33 33 32 31 31 31 26 22 16 14 17 23 29 24 19 17 21 27 31 26 22 21 24 30 31 26 25 26 28 32 35 31 28 28 29 30 31 30 30 29 28 27 27 24 24 20 14 9 7 8 10 11 12 13 15 16 14 14 14 11 8 6 5 5 4 4 4 4 SCALE IN FEET 1 : 80 0' 80' 160' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE D. OFF FIELD LIGHTING DESIGN Rolland Moore Park, 150831 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco ENGINEERED DESIGN By: Daniel Lohman • File #150831r4 • 10-Nov-17 Sports Lighting, LLC. ©1981, 2017 Musco Sports Lighting, LLC. C5 C6 B4 A3 A5 B5 C7 C8 B1 A1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco ENGINEERED DESIGN By: Daniel Lohman • File #150831r4 • 10-Nov-17 Sports Lighting, LLC. ©1981, 2017 Musco Sports Lighting, LLC. C5 C6 B4 A3 A5 B5 C7 C8 B1 A1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.2 0.2 0.3 0.3 0.4 0.5 0.5 0.4 0.3 0.2 0.3 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco ENGINEERED DESIGN By: Daniel Lohman • File #150831r4 • 10-Nov-17 Sports Lighting, LLC. ©1981, 2017 Musco Sports Lighting, LLC. C5 C6 B4 A3 A5 B5 C7 C8 B1 A1 319 569 595 289 372 244 407 1407 4385 10517 24511 27141 22305 29511 24796 23879 25089 34194 25654 13184 11105 18943 18911 11730 6199 3016 558 32 29 26 22 19 17 15 13 11 11 10 10 9 9 8 8 7 5 4 6 5 0 1 1 E. PEDESTRAIN PATH LIGHTING Rolland Moore Park, 150831 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco ENGINEERED DESIGN By: Daniel Lohman • File #150831r4 • 10-Nov-17 Sports Lighting, LLC. ©1981, 2017 Musco Sports Lighting, LLC. C5 C6 B4 A3 A5 B5 C7 C8 B1 A1 11 2 12 3 2 2 14 12 9 7 5 3 2 2 1 1 5 9 12 13 14 14 14 12 10 7 5 3 2 1 1 2 2 3 3 4 5 6 5 4 3 9 7 5 2 1 1 1 2 2 4 5 7 8 9 9 9 8 7 13 15 5 4 2 1 1 2 3 4 6 9 12 14 14 14 14 13 12 7 6 4 2 2 3 5 7 11 14 18 19 20 20 20 21 19 14 12 8 5 4 5 8 12 16 20 23 24 26 26 27 27 25 24 24 25 25 23 21 18 13 9 7 9 13 18 22 26 28 29 29 30 30 30 29 28 27 27 28 30 31 30 28 25 22 18 13 11 13 19 24 29 32 34 33 33 32 31 31 31 26 22 16 14 17 23 29 24 19 17 21 27 31 26 22 21 24 30 31 26 25 26 28 32 35 31 28 28 29 30 31 30 30 29 28 27 27 24 24 20 14 9 7 8 10 11 12 13 15 16 14 14 14 11 8 6 5 5 4 4 4 4 SCALE IN FEET 1 : 80 0' 80' 160' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE F. ENVIRONMENTAL LIGHT CONTROL DESIGN Rolland Moore Park, 150831 ENVIRONMENTAL GLARE IMPACT Not to be reproduced in whole or part without the written consent of Musco ENGINEERED DESIGN By: Daniel Lohman • File #150831r4 • 10-Nov-17 Sports Lighting, LLC. ©1981, 2017 Musco Sports Lighting, LLC. Candelas: + 150,000 100,000 50,000 5,000 1,000 500 250 Rolland Moore Park Fort Collins,CO GLARE IMPACT Summary Map indicates the maximum candela an observer would see when facing the brightest light source from any direcƟon. A well-designed lighƟng system controls light to provide maximum useful on-Įeld illuminaƟon with minimal destrucƟve oī-site glare. GLARE Candela Levels High Glare: 150,000 or more candela Should only occur on or very near the lit area where the light source is in direct view. Care must be taken to minimize high glare zones. SigniĮcant Glare: 25,000 to 75,000 candela Equivalent to high beam headlights of a car. Minimal to No Glare: 500 or less candela Equivalent to 100W incandescent light bulb. G. PHOTOMETRIC REPORT Rolland Moore Park, 150831 Datasheet: TLC-LED-1150, Type 3W, Typical Photometric Report www.musco.com · lighting@musco.com 2017 Musco Sports Lighting, LLC · M-2031-en04-1 1 TESTING NVLAP Lab Code 200702-0 Musco Lighting Photometry Laboratory Oskaloosa, Iowa REPORT NUMBER: MPL01971_M-2031 PAGE: 1 OF 2 ISSUE DATE: 01/12/17 CATALOG NUMBER: L224N_3WEK_AIBCB_30_90 LUMINAIRE: TLC-LED-1150 fixture assembly consisting of: (25) "1x9 array" modules (224 total LEDs) with 0.5" optics (3W), formed side visors; mounted to a gray painted heatsink with welded fins, enclosed with a diecast barrel cover and clear flat glass, with a 17" two-piece external visor. LAMP: Cree Light Emitting Diode (LED); Color kit: ave. 5700K; 75 Typical CRI MOUNTING: 30 degrees below horizon WAVEFORM: DC AMBIENT TEMP: 24.7 C *(SEE PAGE 2 FOR MORE INFORMATION)* FLOODLIGHT CHARACTERISTICS 3H X 3V 719562. AT 0.0 H, -1.0 V 21.9 deg 19.0 deg 38.5 deg 43.1 deg 53045. ( 44.5 % ) 102155. ( 85.7 % ) 119259. (100.0 % ) IES TYPE MAXIMUM CANDLEPOWER HORIZONTAL BEAM ANGLE (50%) VERTICAL BEAM ANGLE (50%) HORIZONTAL FIELD ANGLE (10%) VERTICAL FIELD ANGLE (10%) BEAM LUMENS (% FIXTURE) FIELD LUMENS (% FIXTURE) TOTAL LUMENS (% FIXTURE) ALL CANDELA AND LUMEN VALUES IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY. AXIAL CANDLEPOWER DEG HORIZ. DEG VERT. 90.0 0. 90.0 0. 85.0 0. 85.0 0. 75.0 0. 75.0 0. 65.0 0. 65.0 0. 55.0 0. 55.0 0. 47.5 0. 47.5 0. 42.5 137. 42.5 0. 37.5 545. 37.5 0. 33.0 1411. 33.0 0. 29.0 3056. 29.0 0. 25.5 7137. 25.5 0. 22.5 25188. 22.5 0. 19.5 63971. 19.5 0. 17.0 107769. 17.0 0. 15.0 161358. 15.0 0. 13.0 243042. 13.0 2150. 11.0 356087. 11.0 86491. 9.0 484359. 9.0 204954. Datasheet: TLC-LED-1150, Type 3W, Typical Photometric Report 2 www.musco.com · lighting@musco.com 2017 Musco Sports Lighting, LLC · M-2031-en04-1 Musco Lighting Photometry Laboratory Oskaloosa, Iowa REPORT NUMBER: MPL01971_M-2031 TESTI NG NVLAP Lab Code 200702-0 PAGE: 2 OF 2 ISSUE DATE: 01/12/17 CATALOG NUMBER: L224N_3WEK_AIBCB_30_90 ADDITIONAL INFORMATION NOTE: Data shown is absolute for the sample provided. Report made in accordance with IESNA LM-79:2008 (minus Section 12 for color). Corrections were made for stray light/dark current. Spectral mismatch correction factor was not performed. Goniophotometer calibration (MPL01926 on 11/18/2016) traceable to NIST through lamp ITL-1000-54. The results listed herein relate only to the item tested. Report amended to remove proprietary information. LAB ASSETS: Elgar CW2501, PL0001, AC power supply; Agilent 34410A: PL0040, 6-1/2 Digit DMM to measure voltage drop across shunt; Ohm Labs CS10: PL0017, 10A shunt; Agilent 34410A: PL0036, 6-1/2 Digit DMM to measure forward voltage; Omega Engineering DPi32: PL0033, temp meter; OWL/ITL: PL0008, Type C moving mirror goniophotometer with test distance of 48’ STABILIZATION: Units were operated for stabilization approximately 23 hours before testing. Total on-time was approximately 24-1/2 hours. ACCREDITED: Accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for specific scope of accreditation under Lab Code 200702-0. This NVLAP logo does not imply endorsement by NVLAP, NIST, or any agency of the U.S. Government and this account must not be used to claim such endorsement. CONVERT: Photometric type, luminaire test position and photometric web converted from original test data. H. PERFORMANCE GUARANTEE Rolland Moore Park, 150831 Musco hereby guarantees compliance with the following specifications for your project. Constant light levels are guaranteed for the length of time specified in your warranty. Field Constant Average Illumination Uniformity Lamp Tilt Factor Average kW Demand Baseball 2 30fc/20fc 2.0:1.0/2.5:1.0 1.0 43.79 Baseball 3 30fc/20fc 2.0:1.0/2.5:1.0 1.0 43.79 This guarantee is dependent upon the following: • All test stations matched exactly to the number and location of points supplied with the Musco computer generated light scan for constant light levels. • Pole placement must be within 3 feet of Musco recommendation. • Voltage supply to the ballast of all fixtures must be no less than 97% of the designed secondary voltage. In the unlikely event that these performance specifications are not met, Musco shall provide necessary corrective action at no expense to the owner. We trust this meets with your approval. Musco Sports Lighting, LLC Jeff Rogers Vice-President Sales Rolland Moore Park, 150831 I. STRUCTURAL INFORMATION Rolland Moore Park, 150831 J. CONTROLS AND MONITORING Rolland Moore Park, 150831 Control System Summary Project Information Project #: 150831 Project Name: Rolland Moore Park Date: 10/27/17 Project Engineer: D. Lohman Sales Representative: Richard Wadlow Control System Type: Control and Monitoring Communication Type: Digital Cellular Scan: 150831r3 Document ID: 150831P1V2-1027150932 Distribution Panel Location or ID: Service #1 Total # of Distribution Panel Locations for Project: 1 Design Voltage/Hertz/Phase: 480/60/3 Control Voltage: 120 Project Specific Notes: Materials Checklist Contractor/Customer Supplied: A single control circuit must be supplied per distribution panel location. If the control voltage is NOT available, a control transformer is required. Electrical distribution panel to provide overcurrent protection for circuits Thermal/Magnetic circuit breaker sized per full load amps on Circuit Summary by Zone Chart Wiring: Dedicated control power circuit Power circuit to and from lighting contactors Harnesses for cabinets at remote locations Means of grounding, including lightning ground protection Electrical conduit wireway system Entrance hubs rated NEMA 4: must be die-cast zinc, PVC, or copper-free die-cast aluminum Mounting hardware for cabinets Control circuit lock-on device to prevent unauthorized power interruption to control power Anti-corrosion compound to apply to ends of wire, if necessary Call Control-Link Central TM operations center at 877/347-3319 to schedule activation of the control system upon completion of the installation. Note: Activation may take up to 1 1/2 hours Equipment Listing DESCRIPTION APPROXIMATE SIZE 1.Control and Monitoring Cabinet 24 X 72 2.Control and Monitoring Cabinet 24 X 72 QTY SIZE Total Contactors 24 30 AMP Total Off/On/Auto Switches: 4 IMPORTANT NOTES 1. Please confirm that the design voltage listed above is accurate for this facility. Design voltage/phase is defined as the voltage/phase being connected and utilized at each lighting pole's ballast enclosure disconnect. Inaccurate Control System Summary Rolland Moore Park / 150831 - 150831r3 Service #1 - Page 2 of 5 T:\150\150831P1V2-1027150932.pdf Control System Summary Rolland Moore Park / 150831 - 150831r3 Service #1 - Page 3 of 5 T:\150\150831P1V2-1027150932.pdf CONTROL POWER CONSUMPTION 120V Single Phase VA loading of Musco Supplied Equipment INRUSH: 6483.0 SEALED: 729.8 SWITCHING SCHEDULE Field/Zone Description Zones Baseball 1 1 Baseball 2 2 Baseball 3 3 Baseball 4 4 CIRCUIT SUMMARY BY ZONE POLE CIRCUIT DESCRIPTION # OF FIXTURES # OF DRIVERS *FULL LOAD AMPS CONTACTOR SIZE (AMPS) CONTACTOR ID ZONE A1 Baseball 1 5 5 9.2 30 C1 1 A2 Baseball 1 5 5 9.2 30 C2 1 B1 Baseball 1 7 7 11.8 30 C3 1 B2 Baseball 1 7 7 11.8 30 C4 1 C1 Baseball 1 6 6 9.2 30 C5 1 C2 Baseball 1 6 6 9.2 30 C6 1 A2 Baseball 2 5 5 9.2 30 C7 2 A3 Baseball 2 5 5 9.2 30 C8 2 B2 Baseball 2 7 7 11.8 30 C9 2 B3 Baseball 2 7 7 11.8 30 C10 2 C3 Baseball 2 6 6 9.2 30 C11 2 C4 Baseball 2 6 6 9.2 30 C12 2 A3 Baseball 3 5 5 9.2 30 C13 3 A5 Baseball 3 5 5 9.2 30 C14 3 B4 Baseball 3 7 7 11.8 30 C15 3 B5 Baseball 3 7 7 11.8 30 C16 3 C5 Baseball 3 6 6 9.2 30 C17 3 C6 Baseball 3 6 6 9.2 30 C18 3 A1 Baseball 4 5 5 9.2 30 C19 4 A5 Baseball 4 5 5 9.2 30 C20 4 B1 Baseball 4 7 7 11.8 30 C21 4 B5 Baseball 4 7 7 11.8 30 C22 4 C7 Baseball 4 6 6 9.2 30 C23 4 C8 Baseball 4 6 6 9.2 30 C24 4 *Full Load Amps based on amps per driver. Control System Summary Rolland Moore Park / 150831 - 150831r3 Service #1 - Page 4 of 5 T:\150\150831P1V2-1027150932.pdf PANEL SUMMARY CABINET # CONTROL MODULE LOCATION CONTACTOR ID CIRCUIT DESCRIPTION FULL LOAD AMPS DISTRIBUTION PANEL ID (BY OTHERS) CIRCUIT BREAKER POSITION (BY OTHERS) 1 1 C1 Pole A1 9.21 1 1 C2 Pole A2 9.21 1 1 C3 Pole B1 11.78 1 1 C4 Pole B2 11.78 1 1 C5 Pole C1 9.21 1 1 C6 Pole C2 9.21 1 1 C7 Pole A2 9.21 1 1 C8 Pole A3 9.21 1 1 C9 Pole B2 11.78 1 1 C10 Pole B3 11.78 1 1 C11 Pole C3 9.21 1 1 C12 Pole C4 9.21 2 1 C13 Pole A3 9.21 2 1 C14 Pole A5 9.21 2 1 C15 Pole B4 11.78 2 1 C16 Pole B5 11.78 2 1 C17 Pole C5 9.21 2 1 C18 Pole C6 9.21 2 1 C19 Pole A1 9.21 2 1 C20 Pole A5 9.21 2 1 C21 Pole B1 11.78 2 1 C22 Pole B5 11.78 2 1 C23 Pole C7 9.21 2 1 C24 Pole C8 9.21 ZONE SCHEDULE CIRCUIT DESCRIPTION ZONE SELECTOR SWITCH ZONE DESCRIPTION POLE ID CONTACTOR ID Zone 1 1 Baseball 1 A1 C1 A2 C2 B1 C3 B2 C4 C1 C5 C2 C6 Zone 2 2 Baseball 2 A2 C7 A3 C8 Control System Summary Rolland Moore Park / 150831 - 150831r3 Service #1 - Page 5 of 5 ZONE SCHEDULE CIRCUIT DESCRIPTION ZONE SELECTOR SWITCH ZONE DESCRIPTION POLE ID CONTACTOR ID Zone 3 3 Baseball 3 C6 C18 Zone 4 4 Baseball 4 A1 C19 A5 C20 B1 C21 B5 C22 C7 C23 C8 C24 Control System Flexible control and solid management of your facility — saves operating cost and improves service Get fingertip control of your facilities from your desk your field your home your phone ... from anywhere Musco’s Control-Link® System for new and existing sports facilities With cities and recreational needs growing faster than ever, it’s critical to maximize your available resources and make solid decisions about managing and expanding your facilities. Control-Link is the reliable, cost-effective control system that helps control, monitor, and manage your new recreational facility lighting. In addition, it can control your existing lighting systems and other electrically-operated equipment. Whether for new lighting systems or to upgrade existing lights, the Control-Link system includes our Control-Link Central™ team, the on-site Control-Link equipment, and an industry-leading warranty. Our exclusive Control-Link Central team is staffed 24/7 to assist with your scheduling and reporting needs. Reduce energy cost and staff legwork Control-Link reduces energy usage by operating lights and equipment only when needed. This helps curtail taxpayers’ concerns about lights operating when fields are not in use. The automated system does not require staff to travel from field to field to turn lights on and off. It also eliminates distributing and tracking multiple sets of keys and reduces time coordinating staff and facility schedules. Simplify operations with flexible controls Lighting schedules are entered into an easy-to-use Control-Link Central website or by email, phone, or fax. User passwords have varying access levels that you specify. Passwords, unlike keys, can be issued or cancelled at any time – making seasonal personnel or volunteer changes easier to manage. Emergency schedule changes can be made through Control-Link Central call center staff, and on-site manual controls are provided for your maintenance staff. Reduce hassle with solid management tools Control-Link saves you time overseeing facility operations, scheduling staff, and planning routine maintenance. Control-Link Central stores information about your facility usage, including operating history by facility and user group. The control and monitoring system Musco supplies with new lights provides proactive monitoring, reporting lamp outages to help plan routine maintenance. A preseason light check helps ensure your fields are ready for play. Our Control-Link Central team can assist you in generating reports and analyzing your data to provide tools for efficient operations, allocation of costs, assessment of user fees, proactive maintenance, and facility expansion planning. These capabilities provide significant long-term cost savings and the potential for providing better customer service and innovative uses of your facilities without adding staff. 2 Enter schedules at your convenience Enter schedules from any location via our easy-to-use Control-Link Central™ website, smart phone mobile website, or by email, phone, or fax. 1 • Saves Energy and Staff Costs • Allows Flexible Control • Provides Usage Data and Reports • Increases Security • Provides Reliable Operation • Monitors System Performance Manage your 3 Each Control Module can operate 7 combinations of switches Zone 1 Baseball 1 Zone 2 Baseball 2 Zone 3 Baseball 3 Zone 4 Soccer 1 Zone 5 Soccer 2 Zone 6 Soccer 3 Zone 7 Concessions Equipment is controlled automatically Lights and other equipment such as door locks, concession stands, and security lights are operated per your schedules. 3 Control-Link Central provides support, monitoring, and usage data Control-Link Central supports you every step of the way. Trained staff provides scheduling support and verification, and monitors your lighting system for lamp outages. Control-Link Central’s database stores field usage data by facility and user group. Schedules are 4 stored on-site, backed-up at Control-Link Central Schedules are transmitted from Control-Link Central via digital cellular technology and stored in the on-site equipment controller. 2 “ Thank you so much for providing such an effective and advanced system for scheduling our lights; it has truly revolutionized the way we work.” — Kelly Barker Athletic Field Permit Coordinator Dept. of Parks, Recreation and Marine City of Long Beach, California “ It’s like being an umpire. If people don’t know you’re there, you did a great job. If there aren’t any complaints about the lights, I know the system is doing its job.” — Roger Russomanno Ballfield Operations Supervisor Denver, Colo., Parks and Recreation Dept. “ I use Control-Link Central™ to enter the weekly schedules so I can spend my time taking care of other things … They do a Meet Our Control-Link Central Team Control-Link Central provides trained technical assistance with the helpful, “can-do” attitude you expect from Musco, to solve any last-minute change or issue. ™ ™ 4 Trained Staff Available 24/7 Control-Link Central operators oversee on/off control of over 33,000 fields per night and have experience with controlling over 3.3 million schedules per year worldwide. “We strive to provide a level of service where every customer reaches a live operator, rather than a voice mail system, when they call in. We can make your last-minute scheduling changes happen in just a few minutes.” Ryan Tighe Control-Link Central Manager Call Center This is a partial sample of a customer’s weekly schedule as entered on Musco’s Control-Link website. The current day is always highlighted. Musco Control-Link Usage Report (Auto Only) By Facility, Field Usage Type of Light Usage June, 2010 Summary by Facility Total Hours Saved Facility Total Auto Hours Usage from Early Offs Cowley 112:50 17:08 Dunbar 64:53 29:46 Garland Parklet 49:48 0:00 Herschel Field 256:47 26:05 Total: 484:18 72:59 Summary by Facility, Field Total Hours Saved Facility Field Total Auto Hours Usage from Early Offs Cowley Baseball 63:04 17:08 Cowley Basketball 49:46 0:00 Dunbar Baseball 64:53 29:46 Garland Parklet Courts 49:48 0:00 Herschel Field (Lower) Baseball-FB 81:22 10:23 Herschel Field (Upper) Baseball 79:43 12:02 Herschel Field Basketball 47:51 1:50 Herschel Field Hockey 47:51 1:50 Control-Link Central database stores usage data by field and user group. ©1999, 2003 Musco Lighting 5 Operations Support Control-Link Central provides three options for management and control of your facilities: • Directly control your fields via an easy-to-use website • Enter, edit, and update your schedules from your web-enabled smart phone • Contact Control-Link Central’s team of trained operators 24/7 to enter your schedules and request last minute changes Data Management Control-Link Central offers effective tools to manage and analyze the extensive amount of stored information. Standard reports include usage reports by facility, field, and/or end-user. System and Schedule Monitoring The Control-Link control and monitoring system Musco supplies with new lights checks your system performance each time your lights are turned on. If the system detects lamp outages, it notifies your warranty specialist who contacts you. Preseason checks can be a part of your proactive maintenance program to help make sure your lights are operating properly before the first game. Control-Link Central staff monitors all schedules entered to ensure the controller receives them. In addition, staff monitors the status of the system daily to ensure it’s ready to run your schedules. If they detect any system issues, the Control-Link Central staff contacts you to resolve them before they become a problem. Control-Link Activation Once the on-site equipment is installed, the installing contractor contacts a Musco technician to assist them in commissioning the system. The technician sends sample schedule commands to the Control-Link system to test each lighting zone. The technician also collects baseline diagnostic data the system needs for monitoring. Customer Training Control-Link Central staff provides customer training via New Lighting Installation On-Site Equipment Overview 6 Control-Link Control and Monitoring System Control-Link Retrofit System Existing Lighting Installation The Control-Link® control and monitoring system supplied with new lighting installations provides these features: • Lighting contactors to handle circuit switching • Equipment controller to store and execute schedules • Monitoring module to track system performance and detect problems such as lamp outages • Key-operated manual switches • NEMA type 4 rated enclosures • Factory built and fully tested, ready to install • Optional remote-mounted switches in a lockable cabinet The Control-Link retrofit control system supplied with existing lighting installations provides these features: • Interposing relays to drive your existing lighting contactors • Equipment controller to store and execute schedules • Key-operated manual switches • NEMA type 4 rated enclosures • Factory built and fully tested, ready to install • Optional remote-mounted switches in a lockable cabinet On-Site Equipment Overview 7 The remote manual switches cabinet provides the option of more convenient switch location for maintenance staff. • Lockable cabinet helps prevent tampering for outdoor mounted equipment • Locate up to 300 ft. (wire length) from control cabinet • Connectors and mating plugs for easy installation Optional Remote Manual Switches Cabinet Manual Switches Cabinet Easy to Operate “Musco’s control and monitoring system is definitely a more proactive approach than our previous system. When there is a problem, the monitoring system allows a warranty specialist to immediately notify us. This is a huge asset, as problems are resolved right away. The system is user friendly, very efficient, and easy to operate. Using a phone to call Control-Link Central™ is much easier than our previous system, which required a laptop to dial in and make changes to a particular facility. The simplicity of this system is very refreshing.” Joe Ross Recreation Programmer City of Rialto, Recreation and Community Services Rialto, California Customer Service Second to None “We enjoy the great customer service. The staff answering the phones are so polite and we really appreciate that. We value being able to monitor the usage of the facilities through the website. Control-Link helps ensure that field lights are turned off when they are supposed to be. We no longer receive calls at 1:00 in the morning that the lights were left on. The monitoring system has also been impressive. We received a call during the day that there was a problem with one of the fixtures. After checking the fuses, we replaced one and the system was back to go. The problem was resolved before we would have even been aware there was a problem.” Stephen Cooke Sports Manager, Greenville County Recreation Dept. Assistant District Administrator S.C. District 7 Little League Greenville, South Carolina Corona Park, California Usage Data is Great “It’s been great. It’s ten times better than anything we’ve tried before. The field usage data is great. Our monthly reports needed for financial planning are more accurate and easy to do. That makes setting user fees much easier. The customer service we continue to get from Musco is excellent. I know I can call them anytime, from anywhere, and they’re right there to help, 24 hours a day, 7 days a week.” Judy Flynn Former Recreation Supervisor City of Corona, California Carrollton Sports Complex, Texas Neighbors Appreciate Control-Link “We used to get calls from neighbors every once in a while that the lights had been left on, and someone would have to go out in the middle of the night to turn them off. Neighbors have called us saying how much they appreciate the lights being on only when someone is actually using the field.” Scott Whitaker Park & Recreation Director City of Carrollton, Texas United States patents issued. Control-Link® is a registered trademark of Musco Corporation in the U.S. Control-Link Central™ is a trademark of Musco Corporation. ©1998, 2013 Musco Sports Lighting, LLC · M-1546-enUS-12 www.musco.com email: lighting@musco.com K. ELECTRICAL DISTRIBUTION PLANS Rolland Moore Park, 150831 Refer to Tab C Rolland Moore Park, 150831 L. WARRANTY Rolland Moore Park, 150831 SAMPLE 25-Year Product Assurance & Warranty Program Musco Constant 25 ™ ©2005, 2017 Musco Sports Lighting, LLC · M-1291-enUS-10 Musco has a team of people to ensure fulfillment of our product and services warranty and maintains financial reserves dedicated to support our fulfillment of this warranty. Please keep this document as your signed contract guaranteeing comprehensive service for the 25 year period. - Page 1 of 3 - Musco Sports Lighting, LLC will provide all materials and labor to maintain operation of your lighting system to original design criteria for 25 years, or until maximum hours of coverage have accumulated, whichever comes first. Musco products and services are guaranteed to perform on your project as detailed in this document. Light Average illumination levels are guaranteed as described in the Project Details on the following page. Musco will electronically monitor luminaire operation and operating hours, and will group re-lamp if applicable. Individual luminaire outages that occur during the warranty and maintenance period are repaired when the usage of any field is materially impacted. If actual usage exceeds the maximum hours of coverage, the customer will be required to pay an additional fee in order to maintain the warranty to the end of 25 years. Energy Consumption Average and maximum energy consumptions for your lighting system are guaranteed. Monitoring, Maintenance and Control Services Musco shall monitor the performance of your lighting system, including on/off status, hours of usage and lamp outages. If fixture outages that affect playability are detected, Musco will contact you and proactively dispatch technicians. On-off control of your lighting system is provided via an easy-to-use web site scheduling system, phone, fax, or email. Our trained Control-Link Central™ service center staff is available toll-free 24/7. Regular usage reports are always available on Control-Link Central’s web site. Structural Integrity Your project has been designed to Structural integrity of equipment manufactured by Musco is guaranteed. SAMPLE 25-Year Product Assurance & Warranty Program Musco Constant 25 ™ Project Details Musco products and services are guaranteed to perform on your project as follows: - Page 2 of 3 - Field/Zone Fixture Quantity Lamp Type Average Target Light Level Uniformity Max/Min Total Relamps Included Estimated Annual/25- Year Estimated Usage Hours Maximum Hours of Coverage Project Name: Project Pr Number: Owner: City: State: Product(s) Covered: Date Issued: Expiration: __________________________________________ or maximum hours of coverage noted below, whichever occurs first Total Average kW per hour:________ Total Maximum kW per hour:________ ©2005, 2017 Musco Sports Lighting, LLC · M-1291-enUS-10 SAMPLE ©2005, 2017 Musco Sports Lighting, LLC · M-1291-enUS-10 25-Year Product Assurance & Warranty Program Terms and Conditions Musco Constant 25 ™ - Page 3 of 3 - Service under this Contract is provided by Musco Sports Lighting, LLC (“Musco”) or an authorized servicer approved by Musco. Services performed under this Contract shall consist of furnishing labor and parts necessary to restore the operation of the Covered Product(s) to original design criteria provided such service is necessitated by failure of the Covered Product(s) during normal usage. This Contract covers Product(s) consisting of Musco’s Total Light Control – TLC for LED™ or Green Generation Lighting® with Control-Link® and any additional Musco manufactured product as listed on page 2. “We”, “us” and “our” mean Musco. “You” and “your” mean the purchaser of the Covered Product(s). No one has the authority to change this Contract without the prior written approval of Musco. Musco shall not assume responsibility for their agents or assignees other than as described below. If there is a conflict between the terms of this Contract and information communicated either orally or in writing by one or more of our employees or agents, this Contract shall control. Additional Provisions 1. Availability of Service: Control-Link Central operators shall be available 24/7 via web site, phone, fax, or email. Maintenance service specialists shall be available 8AM to 5PM Central Time, and services shall be rendered during these same hours in your local time zone, Monday through Friday (with the exception of national holidays). Hours of operation are subject to change without notice to you. Musco will exercise all reasonable efforts to perform service under this Contract, but will not be responsible for delays or failure in performing such services caused by adverse weather conditions, acts of any government, failure of transportation, accidents, riots, war, labor actions or strikes or other causes beyond its control. 2. Determination of Repairs: Musco will utilize the field monitoring system and any information provided by the customer to determine when the usage of the field is materially impacted. From this information, Musco will determine needed repair and/or replacement of Covered Product(s) and parts. Repair will be with product(s) of like kind and quality. 3. Your Requirements Under this Contract: You must meet all electrical and installation requirements as specified by the manufacturer. In addition, you promise and assure: full cooperation with Musco, Musco’s technicians and authorized servicers during telephone diagnosis and repair of the Covered Product(s); reasonable accessibility of the Covered Product(s); a non- threatening and safe environment for service. You agree to check fuses and to replace fuses as needed. Musco provides spare fuses in the lowest alpha-numeric numbered enclosure. Musco will replenish spare fuses used. You agree to keep your control system online. This means keeping the required control voltage to the control system at all times. Any deviation from this practice must be discussed with Musco’s Warranty Department. 4. Service Limitations - This Contract does not cover: Maintenance, repair or replacement necessitated by loss or damage resulting from any external causes such as, but not limited to, theft, environmental conditions, negligence, misuse, abuse, improper electrical/power supply, unauthorized repairs by third parties, attachments, damage to cabinetry, equipment modifications, vandalism, animal or insect infestation, physical damage to Covered Products parts or components, failure of existing structures, supporting electrical systems or any non-Musco equipment, or acts of God/ nature (including, but not limited to: earthquake, flood, tornadoes, typhoons, hurricanes or lightning). 5. Contract Limitations: a. EXCLUSIONS FROM COVERAGE: IN NO EVENT WILL MUSCO M. PROJECT REFERENCES Rolland Moore Park, 150831 *Partial Listing **Under Construction Musco Sports Lighting, LLC 2005, 2017 • M-1066-enUS-7 Project Installations: Colorado* www.musco.com • lighting@musco.com Baseball / Softball Barnes Field Softball Complex Loveland, Colorado Denver Christian Baseball Lakewood, Colorado Challenger Park Parker, Colorado City of Durango at Fort Lewis College** Durango, Colorado Colorado School of Mines Golden, Colorado Edora Park Baseball Fort Collins, Colorado England Softball Westminster, Colorado Ft. Carson Softball Colorado Springs, Colorado Joslin Needham Brush, Colorado Long Lake Ranch Arvada, Colorado Ray Ross Park Lakewood, Colorado Rifle Softball Roan Field Rifle, Colorado Schafer Athletic Complex Denver, Colorado Southeast Community Park Fort Collins, Colorado St. Mary’s High School Grace Center Colorado Springs, Colorado Twin Rivers Community Park Greeley, Colorado USAFA Softball USAF Academy, Colorado Vanetta Field Steamboat Springs, Colorado Weld Central High School** Keenesburg, Colorado Widefield Park Colorado Springs, Colorado Multi-Purpose El Pomar Youth Complex Colorado Springs, Colorado Erie Sports Park Erie, Colorado Parkfield Community Park Denver, Colorado Plainview Junior Senior High School** Sheridan Lake, Colorado University of Denver Recreational Fields Denver, Colorado University of Northern Colorado Greely, Colorado Football Adams State University N. PRODUCT INFORMATION Rolland Moore Park, 150831 Datasheet: Light-Structure System™ 1 www.musco.com · lighting@musco.com ©2015, 2016 Musco Sports Lighting, LLC · U.S. and foreign patent(s) issued and pending. · M-2214-en04-1 2 1 3 4 5 Precast Concrete Base Galvanized Steel Pole Electrical Components Enclosure Poletop Luminaire Assembly Wire Harness 5 Easy Pieces™ Complete System from Foundation to Poletop Factory wired, aimed, and tested Fast, trouble-free installation Comprehensive corrosion package Integrated lightning ground TLC for LED™ Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com ©2012, 2016 Musco Sports Lighting, LLC · U.S. patents issued. · M-2215-en04-1 1 DRAFT 01_11-04-2016_JVS TLC for LED™ – Precast Concrete Base Overview The precast concrete base is set directly into the ground and backfilled with concrete. The base includes an integrated lightning ground system. Features Base • Set pole on base in 24 hours • Tapered upper section for slip-fit steel pole • Access holes for wire entry • Epoxy-coated ends prevent water intrusion • Lifting hole accepts load-rated steel rod provided by Musco Integrated Lightning Ground System • Complies with NFPA 780, UL 96A, and EN 62305 standards when installed per Musco installation instructions • UL Listed, Class II Lightning Protection, file number E337467 • Tested up to 100 kA by independent laboratory • Steel pole interfaces with integrated grounding system by means of the pole grounding connector • 2/0 AWG (crossectional area of 67.4 mm2) grounding electrode conductor • Concrete-encased grounding electrode, 20 feet (6.1 m) total length, 1/2 inch (12.7 mm) diameter Technical Specifications Base dimensions vary. For measurements refer to project-specific Foundation and Pole Assembly drawing. Construction • Spun concrete construction • Prestressed steel vertical strands and coil spiral for strength throughout base • Minimum design strength is 9500 lb/in² (65.5 MPa) at 28 days • Meets ASTM C1804 design requirements Quality Assurance Tests • 28-day compressive strength • Bending moment capacity • Grounding system continuity 5 Easy Pieces™ 1 2 3 4 5 Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com ©2012, 2016 Musco Sports Lighting, LLC · U.S. patents issued. · M-2215-en04-1 2 TLC for LED™ – Precast Concrete Base Handhole Conduit adapter plate Wire access hole Tapered upper section for slip-fit steel pole Lifting hole Compacted dirt fill top 2 ft (0.6 m)* Concrete backfill* Grounding electrode conductor Integrated grounding electrode Wireway Pole grounding connector Steel reinforcement *Standard pier foundation shown. Foundation and/or backfill may vary per alternate foundation design. Pole ID 5 Easy Pieces™ 1 2 3 4 5 www.musco.com · lighting@musco.com ©2005, 2016 Musco Sports Lighting, LLC · M-2216-en04-1 Datasheet: Light-Structure System™ 1 TLC for LED™ – Galvanized Steel Pole Overview The galvanized steel pole is designed to slip-fit together with the precast concrete base and the poletop luminaire assembly. Features • Slip-fit connection allows pole assembly with come-alongs • Built-in hardware for attaching electrical components enclosure • Wire access from inside the pole (no exposed wiring or conduit) • Shipped in sections for easier handling • Labeled with pole identification for location on field Technical Specifications Pole dimensions vary. For measurements refer to project specific pole configuration drawing. Construction • Pole designs comply with all major building codes • High strength, low alloy, tapered, round steel pole • Hot-dip galvanizing inside and outside after fabrication meets ASTM-A123 and EN 1461 standards • Conforms to AASHTO stress standards and BS EN 40-3-1 • Grounding lug—rated for aluminum (AL) or copper (CU) wiring • Pole shipped in sections • Stainless steel fasteners passivated and coated • Material certifications are available Quality Assurance Tests • Bending stress • Minimum galvanizing thickness • Straightness measurement 5 Easy Pieces™ 1 2 3 4 5 www.musco.com · lighting@musco.com ©2005, 2016 Musco Sports Lighting, LLC · M-2216-en04-1 Datasheet: Light-Structure System™ 2 TLC for LED™ – Galvanized Steel Pole Electrical components enclosure attachment bracket Electrical components enclosure hub with stainless steel screw threads Slip-fit attachment to precast concrete base Weld mark to identify field side orientation Weld mark to identify field side orientation Jacking ear Wire harness strain relief provided on poles 80 ft (24.5 m) and taller per NEC Wire access handhole Grounding lug (inside handhole) 5 Easy Pieces™ 1 2 3 4 5 Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com ©2015, 2016 Musco Sports Lighting, LLC · ECE 9 · M-2217-en04-1 1 TLC for LED™ – Electrical Components Enclosure 5 Easy Pieces™ 1 2 3 4 5 Overview The electrical components enclosure contains all necessary equipment to operate luminaires. Built-in mounting hardware allows for easy attachment to the galvanized steel pole. Quick connect plugs fasten to the wire harness. Features • Factory-built and tested as a unit • Quick connect plug for easy field wiring • Mounted 10 ft (3 m) above grade for servicing with ladder • Labeled with pole identification and electrical information • Drivers individually fused and spare fuses supplied • Wire access from inside the pole (no exposed wiring or conduit) • Disconnect per circuit Technical Specifications For amperage draws and circuitry refer to project specific document. Construction • 0.08 inch (2 mm) thick, powder-coated aluminum • Enclosure ratings: NEMA 3R, IP54 • Designed to operate in up to 50˚ C (122˚ F) ambient temperature • Full length stainless steel hinge • All stainless steel fasteners passivated and coated • Meets touchsafe standards • Up to four drivers per enclosure • Approximate weight 65 lb (29 kg) • Lower enclosure size 14.25 in (362 mm) wide x 8 in (203 mm) deep x 52.5 in (1334 mm) high • Upper enclosure size 14.25 in (362 mm) wide x 8 in (203 mm) deep x 40.5 in (1029 mm) high Quality Assurance Tests • Grounding continuity • High potential dielectric withstand • Full functionality test F1 Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com ©2015, 2016 Musco Sports Lighting, LLC · ECE 9 · M-2217-en04-1 2 TLC for LED™ – Electrical Components Enclosure 1 2 3 4 5 Ground bar (AL,CU)* Disconnect (CU only)* * Aluminum (AL) Copper (CU) Controller Wiring schematics Surge protection Pole alignment beam switch Spare fuses Terminal blocks Driver Fuses 5 Easy Pieces™ Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com ©2005, 2016 Musco Sports Lighting, LLC · M-2218-en04-1 TLC for LED™ – Wire Harness 5 Easy Pieces™ 1 2 3 4 5 Overview The factory-built wire harness connects the electrical components enclosure to the poletop luminaire assembly. Features • Quick connect plugs for easy field wiring • Factory-assembled support grip alleviates strain on connections • Spiral wound cable eliminates slippage • Protective sleeve prevents wire damage • All internal wiring, no exposed wires • Labels identify pole and luminaires Technical Specifications Construction • Spiral wound, wrapped cable, 14 AWG (cross-sectional area of 2.08 mm2) copper wire • Integral cable support grip • Two wires per driver • Each harness supports up to four drivers • Multiple top connectors may be present if required for number of luminaires Quality Assurance Tests • Connector/load resistance • High potential dielectric withstand • Grounding continuity • Termination crimp Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com ©2005, 2016 Musco Sports Lighting, LLC · M-2218-en04-1 TLC for LED™ – Wire Harness 5 Easy Pieces™ 1 2 3 4 5 Top quick connector Wire tie Top cable support grip Spiral wound cable consisting of 14 AWG (cross-sectional area of 2.08 mm2) copper wire Mid-point cable support grip for poles 80 ft (24.5 m) and taller Flexible protective sleeve Bottom quick connector Wire harness bottom quick connector Cable support grip and snap hook Cable support grip and snap hook (if required) Wire harness top quick connector Enclosure harness quick connector Bar harness quick connector www.musco.com · lighting@musco.com ©2015, 2016 Musco Sports Lighting, LLC · U.S. and foreign patent(s) issued and pending. · M-2219-en04-1 Datasheet: Light-Structure System™ 1 TLC for LED™ – Poletop Luminaire Assembly, Weld On Overview The factory-aimed poletop luminaire assembly is the upper section of the pole and slip-fits together with the galvanized steel pole. Features • Each luminaire is factory-built, tested, and ships as a unit • Luminaires are factory-aimed to two-tenths degree of accuracy • Luminaire mounts and connects in a single step • Slip-fit connection allows assembly with come-alongs • All luminaires are factory-wired to a quick connect harness for easy installation • Labels identify pole and luminaire location • No exposed wiring or conduit • Factory-set pole alignment beam allows easy field alignment Technical Specifications Construction • Crossarms and pole shaft hot-dip galvanizing inside and outside after fabrication meets ASTM-A123 and EN 1461 standards • All aluminum components are powder-coated or anodized to mil-A-8625F and BS 5599 • Luminaire and knuckle are powder-coated die-cast aluminum • All stainless steel fasteners are passivated and coated • Crossarms are constructed of rectangular steel tubing • Polecap is attached with stainless steel lanyard and securing bolt Quality Assurance Tests • Galvanizing thickness • High potential dielectric withstand • Electrical continuity 5 Easy Pieces™ 1 2 3 4 5 www.musco.com · lighting@musco.com ©2015, 2016 Musco Sports Lighting, LLC · U.S. and foreign patent(s) issued and pending. · M-2219-en04-1 Datasheet: Light-Structure System™ TLC for LED™ – Poletop Luminaire Assembly, Weld On 5 Easy Pieces™ 1 2 3 4 5 Fixture styles may vary. MKT-4294 Gen3 Luminaire Views RWS 11 August 2016 17.00 in (432 mm) 21.00 in (533 mm) 26.00 in (660 mm) 27.50 in (699 mm) Datasheet: TLC-LED-1150 Luminaire and Driver www.musco.com · lighting@musco.com U.S. and foreign patent(s) issued and pending • ©2016, 2017 Musco Sports Lighting, LLC • TLC-LED-1150 5700K 75 CRI • M-2209-en04-4 1 Luminaire Data Weight (luminaire) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80 lb (36 kg) UL listing number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E338094 UL listed for USA / Canada . . . . . . . . .UL1598 CSA-C22 .2 No .250 .0 Ingress protection, luminaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP65 Material and finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum, powder-coat painted Wind speed rating (aiming only) . . . . . . . . . . . . . 150 mi/h (67 m/s) Photometric Characteristics Projected lumen maintenance per IES TM-21-11 L90(8 .5k) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >51,000 h L80(8 .5k) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >51,000 h L70(8 .5k) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >51,000 h CIE correlated color temperature . . . . . . . . . . . . . . . . . . . . . . .5700 K Color Rendering Index (CRI), typical . . . . . . . . . . . . . . . . . . . . . . . . . 75 Color Rendering Index (CRI), minimum . . . . . . . . . . . . . . . . . . . . . 70 Lumens1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121,000 Footnotes: 1) Incorporates appropriate dirt depreciation factor for life of luminaire . M L S R 2 + − Fuse L1 Fuse L2* Surge† protection Disconnect Driver Controller (if present) Luminaire * If L2 (com) is neutral then not switched or fused. † Not present if indoor installation. Typical Wiring Datasheet: TLC-LED-1150 Luminaire and Driver www.musco.com · lighting@musco.com U.S. and foreign patent(s) issued and pending • ©2016, 2017 Musco Sports Lighting, LLC • TLC-LED-1150 5700K 75 CRI • M-2209-en04-4 2 Driver Data Electrical Data Rated wattage1 Per driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,150 W Per luminaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,150 W Number of luminaires per driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Starting (inrush) current . . . . . . . . . . . . . . . . . . . . . . . . . .<40 A, 256 μ Fuse rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 A UL ambient temperature rating, electrical components enclosure . . . . . . . . . . . . . . . . . 50˚C (122˚F) Ingress protection, electrical components enclosure . . . . . . . . . . . . . . . . . . . . . . . . .IP54 Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95% Dimming mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .optional Range, energy consumption . . . . . . . . . . . . . . . . . . . . .15 – 100% Range, light output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 – 100% 200 Vac 208 Vac 220 Vac 230 Vac 240 Vac 277 Vac 347 Vac 380 Vac 400 Vac 415 Vac 480 Vac 50/60 Hz 60 Hz 50/60 Hz 50 Hz 50/60 Hz 60 Hz 60 Hz 50/60 Hz 50 Hz 50 Hz 60 Hz Max operating current2 7 .11 A 6 .83 A 6 .46 A 6 .18 A 5 .92 A 5 .13 A 4 .10 A 3 .74 A 3 .56 A 3 .43 A 2 .96 A Footnotes: 1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25˚C ambient temperature environment . 2) Operating current includes allowance for 0 .90 minimum power factor, operating temperature, and LED light source manufacturing tolerances . Notes 1 . Use thermal magnetic HID-rated or D-curve circuit breakers . 2 . See Musco Control System Summary for circuit information . Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com U.S. and foreign patent(s) issued and pending • ©2017 Musco Sports Lighting, LLC • TLC-BT-675 5700K 75CRI • M-2407-en04-1 Luminaire and Driver Components – TLC-BT-675 1 Luminaire Data Weight (luminaire) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 lb (22 kg) UL listing number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E338094 UL Listed for USA / Canada . . . . . . . .UL1598 CSA-C22 .2 No .250 .0 Ingress protection, luminaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP65 Material and finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum, powder-coat painted Wind speed rating (aiming only) . . . . . . . . . . . . . 150 mi/h (67 m/s) Photometric Characteristics Projected lumen maintenance per IES TM-21-11 L90(8 .5k) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >51,000 h L80(8 .5k) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >51,000 h L70(8 .5k) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >51,000 h CIE correlated color temperature . . . . . . . . . . . . . . . . . . . . . . .5700 K Color Rendering Index (CRI), typical . . . . . . . . . . . . . . . . . . . . . . . . . 75 Color Rendering Index (CRI), minimum . . . . . . . . . . . . . . . . . . . . . 70 Lumens1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48,000 Footnotes: 1) Incorporates appropriate dirt depreciation factor for life of luminaire . All components from foundation to poletop are designed to work together in Light-Structure System™ to ensure reliable, trouble-free operation. M T R 1 + − Fuse L1 Fuse L2* Surge† protection Disconnect Driver Controller (if present) Luminaire * If L2 (com) is neutral then not switched or fused. † Not present if indoor installation. Typical Wiring Datasheet: Light-Structure System™ www.musco.com · lighting@musco.com U.S. and foreign patent(s) issued and pending • ©2017 Musco Sports Lighting, LLC • TLC-BT-675 5700K 75CRI • M-2407-en04-1 Luminaire and Driver Components – TLC-BT-675 2 Driver Data Electrical Data Rated wattage1 Per driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .675 W Per luminaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .675 W Number of luminaires per driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Starting (inrush) current . . . . . . . . . . . . . . . . . . . . . . . . . .<40 A, 256 µ Fuse rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 A UL ambient temperature rating, electrical components enclosure . . . . . . . . . . . . . . . . . 50°C (122°F) Ingress protection, electrical components enclosure . . . . . . . . . . . . . . . . . . . . . . . . .IP54 Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96% 200 Vac 208 Vac 220 Vac 230 Vac 240 Vac 277 Vac 347 Vac 380 Vac 400 Vac 415 Vac 480 Vac 50/60 Hz 60 Hz 50/60 Hz 50 Hz 50/60 Hz 60 Hz 60 Hz 50/60 Hz 50 Hz 50 Hz 60 Hz Max operating current2 4 .21 A 4 .04 A 3 .82 A 3 .66 A 3 .51 A 3 .04 A 2 .43 A 2 .22 A 2 .11 A 2 .03 A 1 .76 A Footnotes: 1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25˚C ambient temperature environment . 2) Operating current includes allowance for 0 .90 minimum power factor, operating temperature, and LED light source manufacturing tolerances . Notes 1 . Use thermal magnetic HID-rated or D-curve circuit breakers . 2 . See Musco Control System Summary for circuit information . 20.00 in (508 mm) 16.00 in (406 mm) 26.00 in (660 mm) 25.00 in (635 mm) Safety: UL Product Certification www.musco.com · lighting@musco.com ©2011, 2017 Musco Sports Lighting, LLC · M-1684-en04-10 UL Product Certification for: Musco Sports Lighting, LLC 100 1st Ave W PO Box 808 Oskaloosa, IA 52577 USA UL Category Covers UL Number High-Intensity Discharge Surface-Mounted Luminaires • Green Generation™ luminaires and remote ballast assemblies • SportsCluster® and SportsCluster-2® luminaires and remote ballast assemblies • Light-Structure 2™ and Light-Structure System™ luminaires and remote ballast assemblies • 1000 W Light-Pak™ and Light-Pak indoor luminaires with Multi-Watt™ control system • 1000 W Show-Light™ and Show-Light Green™ luminaires with hooded light actuator system and remote ballast assemblies • 2000 W Mirtran™ luminaire • Stadium 2K Fixture™ 2000 W luminaire and Hot Restrike Green™ 2000 W hot restrike luminaire E33316 Management Equipment, Energy Lighting control systems for: • Control-Link® control and monitoring system • Control-Link retrofit control system E139944 Industrial Control Panels Control panels and enclosures for: • Control-Link® control and monitoring system • Control-Link retrofit control system • Lighting contactor cabinets • Multi-Watt™ control systems E204954 Emergency Lighting and Power Equipment • Auxiliary Lighting Interface Cabinet (ALIC) E311491 Luminaire Fittings Galvanized steel poles 12 ft (3.7 m) or less for: • Poles for Mirtran™ luminaire mounting • Rooftop poles • Special applications E132445 Luminaire Pole in Excess of 12 ft (3.7 m) Galvanized steel poles greater than 12 ft (3.7 m) for: • Light-Structure System™ luminaire mounting • Sportspole™ structure or mounting system and special applications E325078 Safety: UL Product Certification www.musco.com · lighting@musco.com ©2011, 2017 Musco Sports Lighting, LLC · M-1684-en04-10 UL Category Covers UL Number Devices, Scaffolding Service platforms for: • Light-Structure System™ luminaires and remote ballast assemblies • SportsCluster® System luminaires and remote ballast assemblies SA7004 Lightning Conductors, Air Terminals, and Fittings • Light-Structure System™ pole structure concrete base E337467 Light-Emitting-Diode Surface-Mounted Luminaires • LED luminaires and driver assemblies • LED auxiliary luminaires E338094 A copy of the UL Certificate of Compliance is available upon your request. Corrosion Protection www.musco.com · lighting@musco.com ©2005, 2017 Musco Sports Lighting, LLC · M-1502-en04-5 Manufacturer’s Certification of Corrosion Protection for Light-Structure System™ and SportsCluster® Lighting Systems The following standard corrosion protection is provided on your equipment: • All exposed components are constructed of corrosion-resistant material and/or coated to protect against corrosion. • All exposed carbon steel is hot-dip galvanized, meeting ASTM A123 and ISO/EN 1461. • All exposed aluminum is powder-coated with high-performance polyester or anodized. All exterior reflective inserts are anodized, coated with a clear, high-gloss, durable fluorocarbon, and protected from direct environmental exposure to prevent reflective degradation or corrosion. • All exposed hardware and fasteners are stainless steel of 18-8 grade or better, passivated, and coated with an aluminum based thermosetting epoxy resin for protection against corrosion and stress corrosion cracking. Alternately, for hardware in non-stressed applications, an electroless nickel coating meeting ASTM B733 may be used. Pole strapping used to mount certain equipment to light poles is annealed grade 304 stainless steel and passivated. • Certain structural fasteners are carbon steel, galvanized meeting ASTM A153 and ISO/EN 1461 (for hot-dip galvanizing), or ASTM B695 (for mechanical galvanizing). This corrosion protection package only applies to equipment manufactured by Musco. Musco Sports Lighting, LLC Greg Kubbe Product Development Manager O. DELIVERY TIMEFRAME Rolland Moore Park, 150831 Musco Lighting shall deliver equipment to the job site 6 - 8 weeks after submittal approval or release of order. Rolland Moore Park, 150831 P. NON COMPLIANCE Rolland Moore Park, 150831 Rolland Moore Park, 150831 Musco is in full compliance Q. LIFE CYCLE COST SAVINGS Rolland Moore Park, 150831 Metal halide light source 184.7 kilowatts 114 luminaires Diode light source 75.2 kilowatts 72 luminaires Energy Controls How is this possible? Musco's 40 years of developing systems, light control, and application expertise puts more available lumens per watt on the field. Our services team provides all on/off operation, monitoring, and maintenance. 566 tons** 119 cars off the road for one year Assumptions Baseball Field 3 - 50/30fc Baseball Field 4 - 50/30fc Annual operating hours 300 300 Energy: Energy cost per kilowatt hour $0.09 Demand charge per kilowatt hour $0.00 Maintenance: Group relamp - cost per luminaire $266 Spot maintenance over 25 years $3,750 Controls: Labor - turning lights on & off $0.00 Lights on extra time without controls 10% © 2017 Musco Sports Lighting, LLC - M-2264-enUS-3 For your budget . . . for the environment $169,860 Maintenance 150831 25-Year Cost of Ownership Comparison Musco LED ** Equivalent to taking Rolland Moore Park November 10, 2017 25-Year Ownership Savings CO2 reduction Typical 1500 Watt TLC for LED™ City of Fort Collins $50,760 $124,844 $83,310 $12,466 $0 $50,000 $100,000 $150,000 $200,000 $250,000 Maintenance included Controls included Rex Stadium Alamosa, Colorado Battle Mountain High School Edwards, Colorado Cheyenne Mountain Charter Academy Colorado Springs, Colorado Classical Academy Colorado Springs, Colorado Colorado School of Mines Golden, Colorado Colorado State University Hughes Stadium Fort Collins, Colorado Colorado State University Pueblo, Colorado Denver Broncos Field House Denver Broncos Indoor Training Facility – NFL Englewood, Colorado Denver South High School Denver, Colorado Douglas County District Stadium Parker, Colorado Falcon Stadium Air Force Academy Colorado Springs, Colorado Frederick High School Frederick, Colorado La Junta High School La Junta, Colorado Legacy Stadium Aurora, Colorado Manitou Springs High School Manitou Springs, Colorado North Stadium Complex Westminster, Colorado Pine Creek High School Colorado Springs, Colorado Rangeview High School Aurora, Colorado Stutier Bowl Greenwood Village, Colorado University of Colorado Folsom Field Boulder, Colorado Valor Christian Stadium Denver, Colorado Tennis Glenwood Springs Glenwood Springs, Colorado Valor Christian Denver, Colorado Venezia Park Colorado Springs, Colorado Soccer Aurora Sports Park Aurora, Colorado Colorado Mesa University Grand Junction, Colorado Colorado State University Pueblo, Colorado Delta Youth Sports Complex Delta, Colorado Denver University Soccer Stadium Denver, Colorado Dicks Sporting Goods Park Commerce City, Colorado Highland Heritage Regional Park Highlands Ranch, Colorado Holly Sports Complex Thornton, Colorado Lowry Sports Complex Denver, Colorado Peak to Peak Charter School Lafayette, Colorado Rhyolite Park Castle Rock, Colorado UCCS Alpine Field Colorado Springs, Colorado UCCS Mountain Lion Stadium Colorado Springs, Colorado Weld County District 6 Soccer Pitch Greeley, Colorado Other Howellson Ski Hill Steamboat Springs, Colorado Keystone Ski Resort Keystone, Colorado Lacrosse Stadium Air Force Academy Colorado Springs, Colorado Pathfinder Park Horse Arena Canon City, Colorado Ruby Hill Snowboard Park Denver, Colorado University of Colorado Coors Event Center Basketball / Volleyball Boulder, Colorado University of Denver Magness Arena Basketball / Hockey Denver, Colorado University of Denver** Peter Barton Stadium Lacrosse Denver, Colorado Vail Ski Resort Vail, Colorado BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES WHICH INCLUDE, BUT ARE NOT LIMITED TO, ANY DELAY IN RENDERING SERVICE OR LOSS OF USE DURING THE REPAIR PERIOD OF THE COVERED PRODUCT(S) OR WHILE OTHERWISE AWAITING PARTS. b. Limitation of Liability: To the extent permitted by applicable law, the liability of Musco, if any, for any allegedly defective Covered Product(s) or components shall be limited to repair or replacement of the Covered Product(s) or components at Musco’s option. THIS CONTRACT IS YOUR SOLE EXPRESS WARRANTY WITH RESPECT TO THE COVERED PRODUCT(S). ALL IMPLIED WARRANTIES WITH RESPECT TO THE COVERED PRODUCT(S) INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXPRESSLY EXCLUDED. c. For the purposes of and by your acceptance of this Contract you acknowledge and agree that if a surety bond (“Bond”) is provided the warranty and/or maintenance guarantee provided for in this Contract and any corresponding liability on behalf of the issuing surety under the Bond is limited to the first twelve (12) months of said warranty and/or maintenance guarantee coverage period. Any warranty and/or guarantee coverage period in excess of said initial 12 month period does not fall within the scope of the Bond and shall be the sole responsibility of Musco. d. Musco requires reasonable access for a crane or man lift equipment to service the lighting system. Musco will not be responsible for damage from operating the vehicle on the property when the equipment is operated in the prescribed manner over the designated access route. e. Obsolescence or Environmental Restrictions: If during any maintenance or other work performed under this Warranty, any of the parts of the Covered Product(s) are found to be either obsolete, no longer available, or prohibited by any state of federal agency, Musco shall replace said parts with comparable parts and materials with equal operating characteristics solely at Musco’s discretion. The cost of replacement of any obsolete cellular related technology shall be borne by you. Prior to completing any such work, Musco shall notify you of the cost (if any) you will incur in the replacement of such parts under this section. 6. Transfer and Assignment: Except to owners, you shall not have the right to assign or otherwise transfer your rights and obligations under this Contract except with the prior written consent of Musco; however, a successor in interest by merger, operation of law, assignment or purchase or otherwise of your entire business shall acquire all of your interests under this Contract. 7. Governing Law: Unless otherwise governed by applicable state law, the Contract shall be interpreted and enforced according to the laws of the State of Iowa. 8. Subrogation: In the event Musco repairs or replaces any Covered Product(s), parts or components due to any defect for which the manufacturer or its agents or suppliers may be legally responsible, you agree to assign your rights of recovery to Musco. You will be reimbursed for any reasonable costs and expenses you may incur in connection with the assignment of your rights. You will be made whole before Musco retains any amounts it may recover. Signature: ___________________________________________ Vice President of Sales What Our Customers Have to Say telephone, conference, or on-line tutorial covering Control-Link operation, scheduling, website access, and all user functions. ™ ™ Efficient Management Tools The Control-Link website provides easy and efficient scheduling of fields, reports, and control over the access levels of your Control-Link website users. “ We greatly appreciate your super-friendly service.” — Kelly Barker Athletic Field Permit Coordinator Dept. of Parks, Recreation and Marine City of Long Beach, California great job, week after week.” — John Banks Park and Recreation Supervisor Laguna Niguel, California Available 24/7 lights without the late-night hours B2 C9 B3 C10 C3 C11 C4 C12 Zone 3 3 Baseball 3 A3 C13 A5 C14 B4 C15 B5 C16 C5 C17 CONTINUED ON NEXT PAGE design voltage/phase can result in additional costs and delays. Contact your Musco sales representative to confirm this item. 2. In a 3 phase design, all 3 phases are to be run to each pole. When a 3 phase design is used Musco's single phase luminaires come pre-wired to utilize all 3 phases across the entire facility. 3. One contactor is required for each pole. When a pole has multiple circuits, one contactor is required for each circuit. All contactors are UL 100% rated for the published continuous load. All contactors are 3 pole. 4. If the lighting system will be fed from more than one distribution location, additional equipment may be required. Contact your Musco sales representative. 5. A single control circuit must be supplied per control system. 6. Size overcurrent devices using the full load amps column of the Circuit Summary By Zone chart- Minimum power factor is 0.9. NOTE: Refer to Installation Instructions for more details on equipment information and the installation requirements C 1999,2017 Musco Sports Lighting,LLC Form: T-5030-1 T:\150\150831P1V2-1027150932.pdf 7.0 585639. 7.0 343864. 5.0 654702. 5.0 484096. 3.0 697592. 3.0 620842. 1.0 715120. 1.0 710056. 0.0 716637. 0.0 716637. -1.0 715120. -1.0 719562. -3.0 697593. -3.0 712250. -5.0 654702. -5.0 680806. -7.0 585639. -7.0 624498. -9.0 484359. -9.0 528703. -11.0 356087. -11.0 418244. -13.0 243042. -13.0 326279. -15.0 161358. -15.0 264420. -17.0 107769. -17.0 222400. -19.5 63972. -19.5 182529. -22.5 25188. -22.5 140856. -25.5 7137. -25.5 111003. -29.0 3056. -29.0 88130. -33.0 1411. -33.0 64640. -37.5 545. -37.5 43723. -42.5 137. -42.5 25989. -47.5 0. -47.5 15404. -55.0 0. -55.0 7704. -65.0 0. -65.0 4893. -75.0 0. -75.0 5603. -85.0 0. -85.0 318. -90.0 0. -90.0 17. This technical data is the confidential property of Musco Sports-Lighting, LLC. Any reproduction or use of this information in whole or part for anything other than its limited, intended purpose for this project, without the written permission of Musco, is prohibited. Approved Tested By Rian Leedom Kurt Dunkin Photometric Report ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS 1 A1 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 5/3* 1 5 1 3 1 A3 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 1 4 1 4 1 A5 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 2 8 0 0 1 B1 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 1 B4 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 2 6 0 6 1 B5 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 2 12 0 0 4 C5-C8 70' - 15' 70' TLC-BT-675 TLC-LED-1150 2 4 2 4 0 0 10 TOTALS 96 74 22 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s) dimensions are relaƟve to 0,0 reference point(s) Rolland Moore Park Fort Collins,CO GRID SUMMARY Name: Walkways Spacing: 10.0' x 10.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average: 15.20 Maximum: 35 Minimum: 1 Avg / Min: 15.92 Max / Min: 36.50 UG (adjacent pts): 2.27 CU: 0.04 No. of Points: 221 LUMINAIRE INFORMATION Color / CRI: 3000K - 80 CRI Luminaire Output: 101,640 / 40,320 lumens No. of Luminaires: 74 Total Load: 77.03 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1150 >51,000 >51,000 >51,000 TLC-BT-675 >51,000 >51,000 >51,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. 5 0 0 0 1 0 0 0 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 1 0 0 0 0 1 0 0 4 2 0 0 6 5 0 0 2 3 4 3 7 12 14 15 14 9 7 7 7 8 8 8 9 8 6 4 4 4 4 4 3 3 2 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 6 7 8 8 9 9 10 10 11 12 14 17 13 9 7 8 7 10 13 14 14 13 11 11 11 14 39 126 477 2275 7137 11569 7149 3502 2234 874 558 365 644 669 379 200 336 1384 1243 845 SCALE IN FEET 1 : 225 0' 225' 450' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS 1 A1 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 5/3* 1 4 1 4 1 A3 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 1 4 1 4 1 A5 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 2 8 0 0 1 B1 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 1 B4 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 1 B5 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 2 12 0 0 4 C5-C8 70' - 15' 70' TLC-BT-675 TLC-LED-1150 2 4 2 4 0 0 10 TOTALS 96 72 24 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s) dimensions are relaƟve to 0,0 reference point(s) Rolland Moore Park Fort Collins,CO GRID SUMMARY Name: Spill Spacing: 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED CANDELA (PER FIXTURE) EnƟre Grid Scan Average: 1656.3024 Maximum: 34193.72 Minimum: 0.00 No. of Points: 231 LUMINAIRE INFORMATION Color / CRI: 3000K - 80 CRI Luminaire Output: 101,640 / 40,320 lumens No. of Luminaires: 72 Total Load: 75.2 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1150 >51,000 >51,000 >51,000 TLC-BT-675 >51,000 >51,000 >51,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 SCALE IN FEET 1 : 225 0' 225' 450' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS 1 A1 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 5/3* 1 4 1 4 1 A3 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 1 4 1 4 1 A5 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 2 8 0 0 1 B1 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 1 B4 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 1 B5 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 2 12 0 0 4 C5-C8 70' - 15' 70' TLC-BT-675 TLC-LED-1150 2 4 2 4 0 0 10 TOTALS 96 72 24 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s) dimensions are relaƟve to 0,0 reference point(s) Rolland Moore Park Fort Collins,CO GRID SUMMARY Name: Spill Spacing: 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED MAX VERTICAL FOOTCANDLES EnƟre Grid Scan Average: 0.0252 Maximum: 0.52 Minimum: 0.00 No. of Points: 231 LUMINAIRE INFORMATION Color / CRI: 3000K - 80 CRI Luminaire Output: 101,640 / 40,320 lumens No. of Luminaires: 72 Total Load: 75.2 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1150 >51,000 >51,000 >51,000 TLC-BT-675 >51,000 >51,000 >51,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 SCALE IN FEET 1 : 225 0' 225' 450' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS 1 A1 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 5/3* 1 4 1 4 1 A3 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 1 4 1 4 1 A5 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 2 8 0 0 1 B1 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 1 B4 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 1 B5 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 2 12 0 0 4 C5-C8 70' - 15' 70' TLC-BT-675 TLC-LED-1150 2 4 2 4 0 0 10 TOTALS 96 72 24 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s) dimensions are relaƟve to 0,0 reference point(s) Rolland Moore Park Fort Collins,CO GRID SUMMARY Name: Spill Spacing: 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average: 0.0064 Maximum: 0.15 Minimum: 0.00 No. of Points: 231 LUMINAIRE INFORMATION Color / CRI: 3000K - 80 CRI Luminaire Output: 101,640 / 40,320 lumens No. of Luminaires: 72 Total Load: 75.2 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1150 >51,000 >51,000 >51,000 TLC-BT-675 >51,000 >51,000 >51,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS 1 A1 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 5/3* 1 5 1 3 1 A3 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 1 4 1 4 1 A5 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 2 8 0 0 1 B1 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 1 B4 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 2 6 0 6 1 B5 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 2 12 0 0 4 C5-C8 70' - 15' 70' TLC-BT-675 TLC-LED-1150 2 4 2 4 0 0 10 TOTALS 96 74 22 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s) dimensions are relaƟve to 0,0 reference point(s) Rolland Moore Park Fort Collins,CO GRID SUMMARY Name: Walkways Spacing: 10.0' x 10.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average: 15.20 Maximum: 35 Minimum: 1 Avg / Min: 15.92 Max / Min: 36.50 UG (adjacent pts): 2.27 CU: 0.04 No. of Points: 221 LUMINAIRE INFORMATION Color / CRI: 3000K - 80 CRI Luminaire Output: 101,640 / 40,320 lumens No. of Luminaires: 74 Total Load: 77.03 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1150 >51,000 >51,000 >51,000 TLC-BT-675 >51,000 >51,000 >51,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. 26 22 19 19 20 22 21 25 26 22 22 21 20 20 19 18 21 19 19 17 21 22 21 23 19 18 18 19 17 19 26 25 23 22 18 21 25 18 20 29 27 19 24 26 17 B1 A1 65' 172' 50' 69' 287' 104' 104' 287' 65' 50' 172' 74' A5 B5 SCALE IN FEET 1 : 100 0' 100' 200' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS 1 A1 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 5/3* 1 4 1 4 1 A5 70' 10' 25' 80' TLC-BT-675 TLC-LED-1150 1/1* 4/4* 1 4 1 4 1 B1 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 1 B5 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 2 C7-C8 70' - 15' 70' TLC-BT-675 TLC-LED-1150 2 4 2 4 0 0 6 TOTALS 60 36 24 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s) dimensions are relaƟve to 0,0 reference point(s) Rolland Moore Park Fort Collins,CO GRID SUMMARY Name: Baseball 4 Size: 297'/307'/297' - basepath 90' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES InĮeld Ouƞield Guaranteed Average: 30 20 Scan Average: 33.87 21.78 Maximum: 40 33 Minimum: 21 15 Avg / Min: 1.58 1.46 Guaranteed Max / Min: 2 2.5 Max / Min: 1.86 2.24 UG (adjacent pts): 1.34 1.56 CU: 0.69 No. of Points: 25 75 LUMINAIRE INFORMATION Color / CRI: 3000K - 80 CRI Luminaire Output: 40,320 / 101,640 lumens No. of Luminaires: 36 Total Load: 37.6 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-BT-675 >51,000 >51,000 >51,000 TLC-LED-1150 >51,000 >51,000 >51,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. TLC-BT-675 TLC-LED-1150 1/1* 4/4* 1 4 1 4 2 B4-B5 80' - 15' 80' TLC-BT-675 TLC-LED-1150 1/1* 6/6* 1 6 1 6 2 C5-C6 70' - 15' 70' TLC-BT-675 TLC-LED-1150 2 4 2 4 0 0 6 TOTALS 60 36 24 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s) dimensions are relaƟve to 0,0 reference point(s) Rolland Moore Park Fort Collins,CO GRID SUMMARY Name: Baseball 3 Size: 297'/307'/297' - basepath 90' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES InĮeld Ouƞield Guaranteed Average: 30 20 Scan Average: 33.64 21.84 Maximum: 40 34 Minimum: 25 15 Avg / Min: 1.36 1.42 Guaranteed Max / Min: 2 2.5 Max / Min: 1.62 2.19 UG (adjacent pts): 1.25 1.54 CU: 0.70 No. of Points: 25 75 LUMINAIRE INFORMATION Color / CRI: 3000K - 80 CRI Luminaire Output: 101,640 / 40,320 lumens No. of Luminaires: 36 Total Load: 37.6 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1150 >51,000 >51,000 >51,000 TLC-BT-675 >51,000 >51,000 >51,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. 70' TLC-BT-675 TLC-LED-1150 2 4 10 TOTALS 96 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon SINGLE LUMINAIRE AMPERAGE DRAW CHART Ballast SpeciĮcaƟons (.90 min power factor) Line Amperage Per Luminaire (max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-1150 6.8 6.5 5.9 5.1 4.1 3.7 3.0 TLC-BT-675 4.0 3.8 3.5 3.0 2.4 2.2 1.8