Loading...
HomeMy WebLinkAboutRFP - 8330 PHOTO VOLTAIC SOLAR FOR NEW DOWNTOWN PARKING GARAGE (3)RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 1 of 15 REQUEST FOR PROPOSAL 8330 PHOTOVOLTAIC SOLAR FOR DOWNTOWN PARKING GARAGE The City of Fort Collins is requesting proposals from qualified firms to provide materials and install a PV (photovoltaic) solar system on the new Downtown Parking Garage. The successful service provider will design and install a system in the range of 50 kW/DC based on the design and system costs. As part of the City’s commitment to Sustainable Purchasing, proposals submission via email is preferred. Proposals shall be submitted in a single Microsoft Word or PDF file under 20MB and e-mailed to: purchasing@fcgov.com. If electing to submit hard copy proposals instead, five (5) copies, will be received at the City of Fort Collins' Purchasing Division, 215 North Mason St., 2nd floor, Fort Collins, Colorado 80524. Proposals must be received before 3:00 p.m. (our clock), June 23, 2016 and referenced as Proposal No. 8330. If delivered, they are to be sent to 215 North Mason Street, 2nd Floor, Fort Collins, Colorado 80524. If mailed, the address is P.O. Box 580, Fort Collins, 80522-0580. Please note, additional time is required for bids mailed to the PO Box to be received at the Purchasing Office. The City encourages all Disadvantaged Business Enterprises (DBEs) to submit proposals in response to all requests for proposals. No individual or business will be discriminated against on the grounds of race, color, sex, or national origin. It is the City’s policy to create a level playing field on which DBEs can compete fairly and to ensure nondiscrimination in the award and administration of all contracts. A pre proposal conference with representatives of prospective proposers will be held at 10 AM, on June 8, 2016, in the Operation Services 2nd floor conference room, 300 Laporte Ave. Building B, Fort Collins, CO 80521. Prospective proposers are invited to present their questions relative to this proposal at this meeting. Questions concerning the scope of the bid should be directed to Stu Reeve, Energy Manager, at (970) 221-6274 or sreeve@fcgov.com. Questions regarding bid submittal or process should be directed to Elliot Dale, Buyer, at (970) 221-6777 or edale@fcgov.com. All questions must be submitted in writing via email to Stu Reeve , with a copy to Elliot Dale, no later than 5:00 PM our clock on June 14, 2016. Questions received after this deadline will not be answered. Financial Services Purchasing Division 215 N. Mason St. 2nd Floor PO Box 580 Fort Collins, CO 80522 970.221.6775 970.221.6707 fcgov.com/purchasing RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 2 of 15 A copy of the RFP may be obtained at www.rockymountainbidsystem.com. The City of Fort Collins is subject to public information laws, which permit access to most records and documents. Proprietary information in your response must be clearly identified and will be protected to the extent legally permissible. Proposals may not be marked ‘Proprietary’ in their entirety. All provisions of any contract resulting from this request for proposal will be public information. New Vendors: The City requires new vendors receiving awards from the City to fill out and submit an IRS form W-9 and to register for Direct Deposit (Electronic) payment. If needed, the W-9 form and the Vendor Direct Deposit Authorization Form can be found on the City’s Purchasing website at www.fcgov.com/purchasing under Vendor Reference Documents. Sales Prohibited/Conflict of Interest: No officer, employee, or member of City Council, shall have a financial interest in the sale to the City of any real or personal property, equipment, material, supplies or services where such officer or employee exercises directly or indirectly any decision- making authority concerning such sale or any supervisory authority over the services to be rendered. This rule also applies to subcontracts with the City. Soliciting or accepting any gift, gratuity favor, entertainment, kickback or any items of monetary value from any person who has or is seeking to do business with the City of Fort Collins is prohibited. Collusive or sham proposals: Any proposal deemed to be collusive or a sham proposal will be rejected and reported to authorities as such. Your authorized signature of this proposal assures that such proposal is genuine and is not a collusive or sham proposal. The City of Fort Collins reserves the right to reject any and all proposals and to waive any irregularities or informalities. Utilization of Award by Other Agencies: The City of Fort Collins reserves the right to allow other state and local governmental agencies, political subdivisions, and/or school districts to utilize the resulting award under all terms and conditions specified and upon agreement by all parties. Usage by any other entity shall not have a negative impact on the City of Fort Collins in the current term or in any future terms. Sustainability: Consulting firms/teams participating in the proposal are to provide an overview of the organization’s philosophy and approach to Sustainability. In no more than two (2) pages please describe how your organization strives to be sustainable in the use of materials, equipment, vehicles, fuel, recycling, office practices, etc. The City of Fort Collins incorporates the Triple Bottom Line into our decision process by including economic (or financial), environmental, and social factors in our evaluation. The selected Service Provider shall be expected to sign the City’s standard Agreement without revision prior to commencing Services (see sample attached to this Proposal). Sincerely, Gerry S. Paul Purchasing Director RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 3 of 15 8330 PHOTOVOLTAIC SOLAR FOR DOWNTOWN PARKING GARAGE SCOPE OF WORK BACKGROUND The new Downtown Parking Garage is a 40,000 SF/Floor three story parking garage located at 354 Walnut Street in Fort Collins, Co. The facility is scheduled for completion in the fall of 2017. PROJECT DESCRIPTION The City of Fort Collins, Operation Services Department, is seeking proposals from qualified firms to install a PV (photovoltaic) solar system on the roof area structural support infrastructure designed for this system. The Service Provider will design and install a system in the range of 50 kW/DC based on design and system costs. The City would like to maximize the on-site energy production of the building. Architectural and Structural Drawings (Attachment 1) of the facility are provided with this RFP to aid proposers in evaluating what PV equipment can be successfully installed or what modification must be made to insure successful installation. Conduit from the structural support to the main electrical room will be provided. These drawings can be viewed at the end of this RFP document. SCOPE OF SERVICES • Service Provider to complete & pull all Utilities/Building Department permits. • The system must be installed on the structural support as shown on the drawing layout. • The system shall include all necessary materials and equipment to make it fully functional. This includes but not limited to panels, mounting hardware, wiring, conduit and mounting hardware, inverters, disconnects at panel and main garage power disconnect on the outside of the parking structure. • Structural support has been designed into the facility column stem to accommodate wind and snow load. Upon award, consult with the structural engineer for confirmation on final design. • Provide complete installation services for a functional operating system. • PV monitoring and status via remote access must be provided by the Service Provider and is included in this project. Service Provider will submit specifications of monitoring equipment, infrastructure required to attain monitoring (network drop, phone line, etc.) and all associated ongoing fees for monitoring to be addressed. • Ensure that all Fort Collins Utilities interconnection contracts and requirements are met. The systems must comply with all applicable codes and all Fort Collins Utilities requirements. • Provide warranty information and documentation for all equipment installed. • Provide as-built drawings and operation and maintenance manuals for all equipment installed. • Any structural modifications must be completed so as not to void warranties. Any modifications done shall be reviewed by structural engineer and approved by the manufacturer/installer representative. Any costs associated with this manufacturer review shall be included in the proposal and paid for by the Service Provider. • The Service Provider shall pay close attention to fit and finish and paint/hide/minimize conduit runs exposed on the interior and exterior of the facility. Inverter location shall be RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 4 of 15 convenient, but not obtrusive. The inverter location shall be a collaborative decision between the City and the Service Provider as design review evolves. • Project to be completed by October 2017. • The City of Fort Collins will coordinate the Solar Rebate application process with Fort Collins Utilities. Rebates are not to be included in proposal pricing. • Please reference the attached drawing showing an example system design layout (Attachment 1). PROPOSAL SUBMITTAL REQUIREMENTS • Provide an estimate of the total available installed capacity of the proposed equipment at the new downtown parking garage. Provide an annual (by month) PV Watts estimate of the PV systems kWh production. Provide these estimates for all proposed configurations of panel layout (e.g. all south facing, maximum density east west configuration). • Service Provider must be a member of the Colorado Solar Energy Industries Association and equipment provided shall meet the Fort Collins Utilities Eligible Equipment List. • Stamped structural drawings will be provided to the City for record. • Provide 3 previous installations of similarly sized photovoltaic systems preferably on parking garages and shade structures. Include the size of the system, number of panels, kW/DC of electricity and owner contact information (Name, title, organization, phone number, email address). • Describe the impact if any, of the proposed use of any federal, state, or local tax incentives or rebates. • Describe any reorganization/restructuring, including purchases, sales, mergers and name changes within your company within the past three years. • Describe the ability of your selected inverter to provide or be retrofitted for smart inverter functionality (adjustable transient ride through, voltage, VAR, and frequency control, etc.). COST SUBMITTAL REQUIREMENTS • Provide itemized turnkey cost including breakdown for all design, materials, and installation per the scope of work. Contractor must specify American or non-American materials. • The City desires to have American made materials. Contractor may provide costs for either American made or non-American made or costs for both. One alternative to the base system are also requested (optional): 1. Provide the complete system as a power purchase agreement (PPA). The PPA should describe all the financial elements of the project, at a minimum including the proposed per kWh electricity cost for years one through twenty and optional buyout information at the prescribed milestones. RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 5 of 15 SELECTION PROCESS & SCHEDULE Pre-proposal meeting: 10:00 am June 8, 2016 Final day for questions: June 14, 2016 Proposal due date: June 23, 2016 Notify Consultants to be interviewed: Week of June 27th, 2016 Interviews: Week of July 11th, 2016 RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 6 of 15 PROPOSAL REVIEW AND ASSESSMENT Professional firms will be evaluated on the following criteria. These criteria will be the basis for review and assessment of the written proposals and optional interview session. At the discretion of the City, interviews of the top rated firms may be conducted. The rating scale shall be from 1 to 5, with 1 being a poor rating, 3 being an average rating, and 5 being an outstanding rating. WEIGHTING FACTOR QUALIFICATION STANDARD 2.0 Scope of Proposal Does the proposal address all elements of the RFP? Does the proposal show an understanding of the project objectives, methodology to be used and results/outcomes required by the project? Are there any exceptions to the specifications, Scope of Work, or agreement? 2.0 Assigned Personnel Do the persons who will be working on the project have the necessary skills and qualifications? Are sufficient people of the requisite skills and qualifications assigned to the project? 1.0 Availability Can the work be completed in the necessary time? Can the target start and completion dates be met? Are other qualified personnel available to assist in meeting the project schedule if required? Is the project team available to attend meetings as required by the Scope of Work? 1.0 Sustainability/TBL Methodology Does the firm demonstrate a commitment to Sustainability and incorporate Triple Bottom Line methodology in both their Scope of Work for the project, and their day-to-day business operating processes and procedures? 2.0 Cost and Work Hours Does the proposal included detailed cost break-down for each cost element as applicable and are the line- item costs competitive? Do the proposed cost and work hours compare favorably with the Project Manager's estimate? Are the work hours presented reasonable for the effort required by each project task or phase? 2.0 Firm Capability Does the firm have the resources, financial strength, capacity and support capabilities required to successfully complete the project on-time and in- budget? Has the firm successfully completed previous projects of this type and scope? RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 7 of 15 Definitions Sustainable Purchasing is a process for selecting products or services that have a lesser or reduced negative effect on human health and the environment when compared with competing products or services that serve the same purpose. This process is also known as “Environmentally Preferable Purchasing” (EPP), or “Green Purchasing”. The Triple Bottom Line (TBL) is an accounting framework that incorporates three dimensions of performance: economic, or financial; environmental, and social. The generally accepted definition for TBL is that it “captures the essence of sustainability by measuring the impact of an organization’s activities on the world…including both its profitability and shareholders values and its social, human, and environmental capital.” REFERENCE EVALUATION (TOP RATED FIRM) The Project Manager will check references using the following criteria. The evaluation rankings will be labeled Satisfactory/Unsatisfactory. QUALIFICATION STANDARD Overall Performance Would you hire this Professional again? Did they show the skills required by this project? Timetable Was the original Scope of Work completed within the specified time? Were interim deadlines met in a timely manner? Completeness Was the Professional responsive to client needs; did the Professional anticipate problems? Were problems solved quickly and effectively? Budget Was the original Scope of Work completed within the project budget? Job Knowledge a) If a study, did it meet the Scope of Work? b) If Professional administered a construction contract, was the project functional upon completion and did it operate properly? Were problems corrected quickly and effectively? ATTACHMENTS: Attachment 1: Architectural and Structural Drawings RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 8 of 15 SERVICES AGREEMENT THIS AGREEMENT made and entered into the day and year set forth below by and between THE CITY OF FORT COLLINS, COLORADO, a Municipal Corporation, hereinafter referred to as the "City" and , hereinafter referred to as "Service Provider". WITNESSETH: In consideration of the mutual covenants and obligations herein expressed, it is agreed by and between the parties hereto as follows: 1. Scope of Services. The Service Provider agrees to provide services in accordance with the scope of services attached hereto as Exhibit "A", consisting of ( ) page and incorporated herein by this reference. Irrespective of references in Exhibit A to certain named third parties, Service Provider shall be solely responsible for performance of all duties hereunder. 2. The Work Schedule. [Optional] The services to be performed pursuant to this Agreement shall be performed in accordance with the Work Schedule attached hereto as Exhibit "B", consisting of ( ) page , and incorporated herein by this reference. 3. Time of Commencement and Completion of Services. The services to be performed pursuant to this Agreement shall be initiated within ( ) days following execution of this Agreement. Services shall be completed no later than . Time is of the essence. Any extensions of the time limit set forth above must be agreed upon in a writing signed by the parties. 4. Contract Period. This Agreement shall commence , 200 , and shall continue in full force and effect until , 200 , unless sooner terminated as herein provided. In addition, at the option of the City, the Agreement may be extended for additional one year periods not to exceed ( ) additional one year periods. Renewals and pricing changes shall be negotiated by and agreed to by both parties. Written notice of renewal shall be provided to the Service Provider and mailed no later than thirty (30) days prior to contract end. 5. Delay. If either party is prevented in whole or in part from performing its obligations by unforeseeable causes beyond its reasonable control and without its fault or negligence, then the party so prevented shall be excused from whatever performance is prevented by such cause. To the extent that the performance is actually prevented, the Service Provider must provide written notice to the City of such condition within fifteen (15) days from the onset of such condition. 6. Early Termination by City/Notice. Notwithstanding the time periods contained herein, the City may terminate this Agreement at any time without cause by providing written notice of termination to the Service Provider. Such notice shall be delivered at least fifteen (15) days prior to the termination date contained in said notice unless otherwise agreed in RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 9 of 15 writing by the parties. All notices provided under this Agreement shall be effective when mailed, postage prepaid and sent to the following addresses: Service Provider: City: Copy to: Attn: City of Fort Collins Attn: PO Box 580 Fort Collins, CO 80522 City of Fort Collins Attn: Purchasing Dept. PO Box 580 Fort Collins, CO 80522 In the event of early termination by the City, the Service Provider shall be paid for services rendered to the date of termination, subject only to the satisfactory performance of the Service Provider's obligations under this Agreement. Such payment shall be the Service Provider's sole right and remedy for such termination. 7. Contract Sum. The City shall pay the Service Provider for the performance of this Contract, subject to additions and deletions provided herein, ($ ) as per the attached Exhibit " ", consisting of page , and incorporated herein by this reference. 8. City Representative. The City will designate, prior to commencement of the work, its representative who shall make, within the scope of his or her authority, all necessary and proper decisions with reference to the services provided under this agreement. All requests concerning this agreement shall be directed to the City Representative. 9. Independent Service provider. The services to be performed by Service Provider are those of an independent service provider and not of an employee of the City of Fort Collins. The City shall not be responsible for withholding any portion of Service Provider's compensation hereunder for the payment of FICA, Workmen's Compensation or other taxes or benefits or for any other purpose. 10. Subcontractors. Service Provider may not subcontract any of the Work set forth in the Exhibit A, Statement of Work without the prior written consent of the city, which shall not be unreasonably withheld. If any of the Work is subcontracted hereunder (with the consent of the City), then the following provisions shall apply: (a) the subcontractor must be a reputable, qualified firm with an established record of successful performance in its respective trade performing identical or substantially similar work, (b) the subcontractor will be required to comply with all applicable terms of this Agreement, (c) the subcontract will not create any contractual relationship between any such subcontractor and the City, nor will it obligate the City to pay or see to the payment of any subcontractor, and (d) the work of the subcontractor will be subject to inspection by the City to the same extent as the work of the Service Provider. 11. Personal Services. It is understood that the City enters into the Agreement based on the special abilities of the Service Provider and that this Agreement shall be considered as an agreement for personal services. Accordingly, the Service Provider shall neither assign any responsibilities nor delegate any duties arising under the Agreement without the prior RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 10 of 15 written consent of the City. 12. Acceptance Not Waiver. The City's approval or acceptance of, or payment for any of the services shall not be construed to operate as a waiver of any rights or benefits provided to the City under this Agreement or cause of action arising out of performance of this Agreement. 13. Warranty. a. Service Provider warrants that all work performed hereunder shall be performed with the highest degree of competence and care in accordance with accepted standards for work of a similar nature. b. Unless otherwise provided in the Agreement, all materials and equipment incorporated into any work shall be new and, where not specified, of the most suitable grade of their respective kinds for their intended use, and all workmanship shall be acceptable to City. c. Service Provider warrants all equipment, materials, labor and other work, provided under this Agreement, except City-furnished materials, equipment and labor, against defects and nonconformances in design, materials and workmanship/workwomanship for a period beginning with the start of the work and ending twelve (12) months from and after final acceptance under the Agreement, regardless whether the same were furnished or performed by Service Provider or by any of its subcontractors of any tier. Upon receipt of written notice from City of any such defect or nonconformances, the affected item or part thereof shall be redesigned, repaired or replaced by Service Provider in a manner and at a time acceptable to City. 14. Default. Each and every term and condition hereof shall be deemed to be a material element of this Agreement. In the event either party should fail or refuse to perform according to the terms of this agreement, such party may be declared in default thereof. 15. Remedies. In the event a party has been declared in default, such defaulting party shall be allowed a period of ten (10) days within which to cure said default. In the event the default remains uncorrected, the party declaring default may elect to (a) terminate the Agreement and seek damages; (b) treat the Agreement as continuing and require specific performance; or (c) avail himself of any other remedy at law or equity. If the non-defaulting party commences legal or equitable actions against the defaulting party, the defaulting party shall be liable to the non-defaulting party for the non-defaulting party's reasonable attorney fees and costs incurred because of the default. 16. Binding Effect. This writing, together with the exhibits hereto, constitutes the entire agreement between the parties and shall be binding upon said parties, their officers, employees, agents and assigns and shall inure to the benefit of the respective survivors, heirs, personal representatives, successors and assigns of said parties. 17. Indemnity/Insurance. RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 11 of 15 a. The Service Provider agrees to indemnify and save harmless the City, its officers, agents and employees against and from any and all actions, suits, claims, demands or liability of any character whatsoever brought or asserted for injuries to or death of any person or persons, or damages to property arising out of, result from or occurring in connection with the performance of any service hereunder. b. The Service Provider shall take all necessary precautions in performing the work hereunder to prevent injury to persons and property. c. Without limiting any of the Service Provider's obligations hereunder, the Service Provider shall provide and maintain insurance coverage naming the City as an additional insured under this Agreement of the type and with the limits specified within Exhibit , consisting of one (1) page, attached hereto and incorporated herein by this reference. The Service Provider before commencing services hereunder, shall deliver to the City's Director of Purchasing and Risk Management, P. O. Box 580, Fort Collins, Colorado 80522, one copy of a certificate evidencing the insurance coverage required from an insurance company acceptable to the City. 18. Entire Agreement. This Agreement, along with all Exhibits and other documents incorporated herein, shall constitute the entire Agreement of the parties. Covenants or representations not contained in this Agreement shall not be binding on the parties. 19. Law/Severability. The laws of the State of Colorado shall govern the construction interpretation, execution and enforcement of this Agreement. In the event any provision of this Agreement shall be held invalid or unenforceable by any court of competent jurisdiction, such holding shall not invalidate or render unenforceable any other provision of this Agreement. 20. Prohibition Against Employing Illegal Aliens. Pursuant to Section 8-17.5-101, C.R.S., et. seq., Service Provider represents and agrees that: a. As of the date of this Agreement: 1. Service Provider does not knowingly employ or contract with an illegal alien who will perform work under this Agreement; and 2. Service Provider will participate in either the e-Verify program created in Public Law 208, 104th Congress, as amended, and expanded in Public Law 156, 108th Congress, as amended, administered by the United States Department of Homeland Security (the “e-Verify Program”) or the Department Program (the “Department Program”), an employment verification program established pursuant to Section 8-17.5-102(5)(c) C.R.S. in order to confirm the employment eligibility of all newly hired employees to perform work under this Agreement. b. Service Provider shall not knowingly employ or contract with an illegal alien to perform work under this Agreement or knowingly enter into a contract with a subcontractor that knowingly employs or contracts with an illegal alien to perform work under this Agreement. RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 12 of 15 c. Service Provider is prohibited from using the e-Verify Program or Department Program procedures to undertake pre-employment screening of job applicants while this Agreement is being performed. d. If Service Provider obtains actual knowledge that a subcontractor performing work under this Agreement knowingly employs or contracts with an illegal alien, Service Provider shall: 1. Notify such subcontractor and the City within three days that Service Provider has actual knowledge that the subcontractor is employing or contracting with an illegal alien; and 2. Terminate the subcontract with the subcontractor if within three days of receiving the notice required pursuant to this section the subcontractor does not cease employing or contracting with the illegal alien; except that Service Provider shall not terminate the contract with the subcontractor if during such three days the subcontractor provides information to establish that the subcontractor has not knowingly employed or contracted with an illegal alien. e. Service Provider shall comply with any reasonable request by the Colorado Department of Labor and Employment (the “Department”) made in the course of an investigation that the Department undertakes or is undertaking pursuant to the authority established in Subsection 8-17.5-102 (5), C.R.S. f. If Service Provider violates any provision of this Agreement pertaining to the duties imposed by Subsection 8-17.5-102, C.R.S. the City may terminate this Agreement. If this Agreement is so terminated, Service Provider shall be liable for actual and consequential damages to the City arising out of Service Provider’s violation of Subsection 8-17.5-102, C.R.S. g. The City will notify the Office of the Secretary of State if Service Provider violates this provision of this Agreement and the City terminates the Agreement for such breach. 21. Special Provisions. Special provisions or conditions relating to the services to be performed pursuant to this Agreement are set forth in Exhibit " " - Confidentiality, consisting of one (1) page, attached hereto and incorporated herein by this reference. RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 13 of 15 THE CITY OF FORT COLLINS, COLORADO By: Gerry Paul Purchasing Director DATE: ATTEST: City Clerk APPROVED AS TO FORM: Senior Assistant City Attorney SERVICE PROVIDER'S NAME By: Printed: Title: CORPORATE PRESIDENT OR VICE PRESIDENT Date: RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 14 of 15 EXHIBIT INSURANCE REQUIREMENTS 1. The Service Provider will provide, from insurance companies acceptable to the City, the insurance coverage designated hereinafter and pay all costs. Before commencing work under this bid, the Service Provider shall furnish the City with certificates of insurance showing the type, amount, class of operations covered, effective dates and date of expiration of policies, and containing substantially the following statement: “The insurance evidenced by this Certificate will not reduce coverage or limits and will not be cancelled, except after thirty (30) days written notice has been received by the City of Fort Collins.” In case of the breach of any provision of the Insurance Requirements, the City, at its option, may take out and maintain, at the expense of the Service Provider, such insurance as the City may deem proper and may deduct the cost of such insurance from any monies which may be due or become due the Service Provider under this Agreement. The City, its officers, agents and employees shall be named as additional insureds on the Service Provider 's general liability and automobile liability insurance policies for any claims arising out of work performed under this Agreement. 2. Insurance coverages shall be as follows: A. Workers' Compensation & Employer's Liability. The Service Provider shall maintain during the life of this Agreement for all of the Service Provider's employees engaged in work performed under this agreement: 1. Workers' Compensation insurance with statutory limits as required by Colorado law. 2. Employer's Liability insurance with limits of $100,000 per accident, $500,000 disease aggregate, and $100,000 disease each employee. B. Commercial General & Vehicle Liability. The Service Provider shall maintain during the life of this Agreement such commercial general liability and automobile liability insurance as will provide coverage for damage claims of personal injury, including accidental death, as well as for claims for property damage, which may arise directly or indirectly from the performance of work under this Agreement. Coverage for property damage shall be on a "broad form" basis. The amount of insurance for each coverage, Commercial General and Vehicle, shall not be less than $1,000,000 combined single limits for bodily injury and property damage. In the event any work is performed by a subcontractor, the Service Provider shall be responsible for any liability directly or indirectly arising out of the work performed under this Agreement by a subcontractor, which liability is not covered by the subcontractor's insurance. RFP 8330 Photovoltaic Solar for Downtown Parking Garage Page 15 of 15 EXHIBIT CONFIDENTIALITY IN CONNECTION WITH SERVICES provided to the City of Fort Collins (the “City”) pursuant to this Agreement (the “Agreement”), the Service Provider hereby acknowledges that it has been informed that the City has established policies and procedures with regard to the handling of confidential information and other sensitive materials. In consideration of access to certain information, data and material (hereinafter individually and collectively, regardless of nature, referred to as “information”) that are the property of and/or relate to the City or its employees, customers or suppliers, which access is related to the performance of services that the Service Provider has agreed to perform, the Service Provider hereby acknowledges and agrees as follows: That information that has or will come into its possession or knowledge in connection with the performance of services for the City may be confidential and/or proprietary. The Service Provider agrees to treat as confidential (a) all information that is owned by the City, or that relates to the business of the City, or that is used by the City in carrying on business, and (b) all information that is proprietary to a third party (including but not limited to customers and suppliers of the City). The Service Provider shall not disclose any such information to any person not having a legitimate need-to-know for purposes authorized by the City. Further, the Service Provider shall not use such information to obtain any economic or other benefit for itself, or any third party, except as specifically authorized by the City. The foregoing to the contrary notwithstanding, the Service Provider understands that it shall have no obligation under this Agreement with respect to information and material that (a) becomes generally known to the public by publication or some means other than a breach of duty of this Agreement, or (b) is required by law, regulation or court order to be disclosed, provided that the request for such disclosure is proper and the disclosure does not exceed that which is required. In the event of any disclosure under (b) above, the Service Provider shall furnish a copy of this Agreement to anyone to whom it is required to make such disclosure and shall promptly advise the City in writing of each such disclosure. In the event that the Service Provider ceases to perform services for the City, or the City so requests for any reason, the Service Provider shall promptly return to the City any and all information described hereinabove, including all copies, notes and/or summaries (handwritten or mechanically produced) thereof, in its possession or control or as to which it otherwise has access. The Service Provider understands and agrees that the City’s remedies at law for a breach of the Service Provider’s obligations under this Confidentiality Agreement may be inadequate and that the City shall, in the event of any such breach, be entitled to seek equitable relief (including without limitation preliminary and permanent injunctive relief and specific performance) in addition to all other remedies provided hereunder or available at law. Project Number: 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 LAT:40° 58'N LON:105° 07'W WALNUT STREET 354, LLC 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 PARKING GARAGE OWNER DOWNTOWN FORT COLLINS PARKING GARAGE 13 MAY 2016 GMP/ PERMIT SET 165 CHESTNUT ST. FORT COLLINS, COLORADO 80524 21129.02 Attachment 1 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 10:35:34 AM G000 SHEET INDEX 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SHEET INDEX SHEET NUMBER SHEET NAME 13 MAY 2016 GMP/ PERMIT SET 1 GENERAL G0 COVER O G000 SHEET INDEX O G011 GENERAL INFORMATION O G021 CODE SUMMARY O G100 CODE ANALYSIS - FIRE SEPARATION DISTANCE O G101 CODE ANALYSIS - FIRE RATED WALLS O G102 CODE ANALYSIS - FIRE RATED WALLS O G103 CODE ANALYSIS - FIRE RATED WALLS O G201 CODE ANALYSIS - EGRESS & TRAVEL DISTANCE O G202 CODE ANALYSIS - EGRESS & TRAVEL DISTANCE O X 101 ROOM NAME 101 X A3 EL= LEVEL X' - X" ROOM NUMBER DOOR TYPE NUMBER WINDOW TYPE NUMBER REVISION NUMBER 1 ELEVATION HEIGHT FLOOR LEVEL OR DATUM DESCRIPTION EL= LEVEL X' - X" CLEAR HEIGHT FINISH CEILING OR SOFFIT DESCRIPTION SHEET NUMBER DRAWING NUMBER X XXXX XXXX X X X X SHEET NUMBER SHEET NUMBER DRAWING NUMBER ROOM IDENTIFICATION DOOR IDENTIFICATION WINDOW IDENTIFICATION REVISION NOTE REFERENCE LEVEL OR DATUM ELEVATION CEILING HEIGHT REFERENCE BUILDING SECTION REFERENCE EXTERIOR ELEVATION REFERENCE INTERIOR ELEVATION REFERENCE 1 / A101 SHEET NUMBER 1 / A101 DRAWING NUMBER MATCHLINE GRID LINE GRID LETTER BUILDING TRANSVERSE GRID GRID NUMBER X BUILDING LONGITUDINAL GRID WALL TYPE REFERENCE WALL TYPE NUMBER WALL LOCATION TAIL X XXXX X XXXX GOVERNING CODES ARCHITECTURAL DESIGN: 2012 INTERNATIONAL BUILDING CODE (IBC) STRUCTURAL DESIGN: 2012 INTERNATIONAL BUILDING CODE (IBC) MECHANICAL, PLUMBING, AND FIRE PROTECTION DESIGN: 2012 INTERNATIONAL MECHANICAL CODE (IMC) 2012 INTERNATIONAL PLUMBING CODE (IPC) 2012 INTERNATIONAL FIRE CODE, AS REFEREED BY IBC (IFC) 2012 INTERNATIONAL FUEL GAS CODE (IFGC) 2001 NFPA - 15 2002 NFPA - 13, 13D, 13R, 17, 17A, 24, 25, & 72 2003 NFPA - 14, 16, 20, 22. & 750 2004 NFPA - 12a, 409, 423, & 2001 2005 NFPA - 11 & 12 2006 NFPA - 1 ELECTRICAL DESIGN: 2014 NATIONAL ELECTRICAL CODE (NEC) ENERGY CONSERVATION DESIGN: 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ACCESSIBILITY DESIGN: ICC/ANSI A117.1 - 2009 ELEVATOR DESIGN: 2007 ASME A17.1 - 2007: SAFETY CODE FOR ELEVATORS AND ESCALATORS AMENDMENTS: LOCAL AMENDMENTS FIRE DISTRICT: POUDRE FIRE AUTHORITY CODE SUMMARY BUILDING ADDRESS: 165 CHESTNT ST. FORT COLLINS, CO 80524 USE AND OCCUPANCY CLASSIFICATIONS - CHAPTER 3 M: RETAIL (IBC 309.1) S-2: PARKING GARAGE, OPEN (IBC SECTION 311.3) DESIGN OCCUPANT LOAD (IBC TABLE 1004.1.2) FUNCTION OF SPACE FL. AREA(SF)/OCC. ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOMS 300 SF GROSS MERCANTILE - RETAIL 30 SF GROSS PARKING GARAGES 200 SF GROSS CONSTRUCTION TYPE: IB OPEN PARKING GARAGE (IBC TABLE 503) IB RETAIL / OFFICE (IBC TABLE 506) ALLOWABLE BUILDING HEIGHT: GROUP S-2 OPEN PARKING GARAGE STORIES = 11, ACTUAL = 3 STORIES) HEIGHT = 160', ACTUAL = 38'-8" AT ELEVATOR TOWER GROUP M RETAIL GROUP B OFFICE ALLOWABLE BUILDING AREA: RETAIL (GROUP M) TYPE IIB 2 STORIES 12,500 SF OPEN PARKING GARAGE (GROUP S-2) TYPE IB 8 TIERS 50,000 SF (PER TIER) AREA SUMMARY AREA OF OPEN PARKING GARAGE OCCUPANCY TYPE LEVEL 01: 37,320 SF S-2 LEVEL 01: 2,650 SF M LEVEL 02: 39,607 SF S-2 LEVEL 03: 39,607 SF S-2 TOTAL: 119,184 SF FIRE DISTRICT: POUDRE FIRE AUTHORITY FIRE RESISTANCE RATING REQUIREMENTS - GARAGE TYPE IIB (IBC TABLE 601) MAXIMUM AREA OF EXTERIOR WALL OPENINGS (IBC TABLE 705.8) 0' TO LESS THAN 3' FIRE SEPARATION DISTANCE = NOT PERMITTED (UP, NS) 3' TO LESS THAN 5' FIRE SEPARATION DISTANCE = NOT PERMITTED (UP, NS) 5' TO LESS THAN 10' FIRE SEPARATION DISTANCE = 10% (UP, NS) 10' TO LESS THAN 15' FIRE SEPARATION DISTANCE = 15% (UP, NS) 15' TO LESS THAN 20' FIRE SEPARATION DISTANCE = 25% (UP, NS) UP FD FD FD FD FD FD FD FD FD FD FD FD UP . MAX. AREA OF EXTERIOR. WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE. (IBC TABLE 705.8) FIRE SEPARATION DISTANCE 30' & ABOVE UNPROTECTED, NONSPRINKLERED (UP, NS) ALLOWABLE AREA: NO LIMIT C.L. ROW. CHESTNUT STREET JEFFERSON STREET (100' ROW) (100' ROW) OLD FIREHOUSE ALLEY C.L. ROW. 54'-5 5/8" 56'-5 5/8" . MAX. AREA OF EXTERIOR. WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE. (IBC TABLE 705.8) FIRE SEPARATION DISTANCE 30' & ABOVE UNPROTECTED, NONSPRINKLERED (UP, NS) ALLOWABLE AREA: NO LIMIT 26'-10 5/8" 14'-7 5/8" 18'-6 1/8" 36'-10 1/8" C.L. ROW. 21'-4 1/2" 19'-0 7/8" 5'-6" 5'-10 1/2" P.L. P.L. P.L. P.L. . MAX. AREA OF EXTERIOR. WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE. (IBC TABLE 705.8) FIRE SEPARATION DISTANCE 20' TO 25' UNPROTECTED, NONSPRINKLERED (UP, NS) ALLOWABLE AREA: 45% OPEN PARKING EXCEPTION: NO LIMIT . MAX. AREA OF EXTERIOR. WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE. (IBC UP UP FD FD FD FD FD FD FD FD FD FD FD FD UP OCCUPANCY: AREA SUBTOTAL: LOAD FACTOR: OCCUPANT LOAD: FUNCTION: 76 SF MECHANICAL 300 SF 1 MECH. MECH. OCCUPANCY: AREA SUBTOTAL: LOAD FACTOR: OCCUPANT LOAD: FUNCTION: 1127 SF STORAGE 300 SF 4 S-2 OCCUPANCY: AREA SUBTOTAL: LOAD FACTOR: OCCUPANT LOAD: FUNCTION: 2650 SF FUTURE RETAIL 30 SF 88 M RETAIL REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: REQ'D STAIR WIDTH: STAIR 02 95 .15"/OCC = 14.25" < 38" ACTUAL .30"/OCC = 28.5" < 48" ACTUAL MECH. ROOM STAIR 02 FUTURE RETAIL STORAGE ROOM SERVER ROOM UP DN DN UP FD FD FD FD FD FD FD FD FD FD FD FD FD REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: REQ'D STAIR WIDTH: STAIR 02 99 .15"/OCC = 14.85" < 36" ACTUAL .30"/OCC = 29.7" < 48" ACTUAL 99 OCCUPANCY: AREA SUBTOTAL: LOAD FACTOR: OCCUPANT LOAD: FUNCTION: 39619 SF PARKING 200 SF 198 S-2 PARKING 99 REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: REQ'D STAIR WIDTH: STAIR 01 99 .15"/OCC = 14.85" < 68" ACTUAL .30"/OCC = 29.7" < 48" ACTUAL ELEV. STAIR 01 STAIR 02 FIRE RESISTANCE - RATED WALL LEGEND (IBC 708) WALL SYMBOL DESCRIPTION LOCATION / PURPOSE FIRE RESISTIVE RATING (1) FIRE DAMPER RATING (2) SMOKE DAMPER RATING (3) FIRE DOOR / SHUTTER RATING (4) NOTES: (1) THE FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE > 5 FEET SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE; FOR A FIRE SEPARATION DISTANCE < OR = 5 FEET, SUCH WALLS SHALL BE RATED FOR EXPOSURE TO FIRE FROM BOTH SIDES. DN DN FD FD FD FD SHEET NOTES: 1. SEE A500 SERIES FOR WALL TYPES. ALL FIRE RATED WALLS/BARRIERS WILL EXTEND TO THE OUTSIDE FACE OF ALL WALL ASSEMBLIES 2. ALL RATED WALLS WILL INCLUDE DOOR OPENING, HEADER, AND FRAMES 3. ALL INTERIOR SHAFTS WILL BE 2HR RATED 4. FIRE RESISTANCE - RATED WALL LEGEND (IBC 708) WALL SYMBOL DESCRIPTION LOCATION / PURPOSE FIRE RESISTIVE RATING (1) FIRE DAMPER RATING (2) SMOKE DAMPER RATING (3) FIRE DOOR / SHUTTER RATING (4) NOTES: (1) THE FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE > 5 FEET SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE; FOR A FIRE SEPARATION DISTANCE < OR = 5 FEET, SUCH WALLS SHALL BE RATED FOR EXPOSURE TO FIRE FROM BOTH SIDES. (2) SEE MECHANICAL DOCUMENTATION FOR LOCATIONS OF FIRE DAMPERS. (3) SEE MECHANICAL DOCUMENTATION FOR LOCATIONS OF SMOKE DAMPERS. (4) SEE ARCHITECTURAL DOCUMENTATION FOR LOCATIONS OF FIRE DOORS AND FIRE SHUTTERS. (5) NOT REQUIRED AT PENETRATION OF EXHAUST OR SUPPLY SHAFTS IN PARKING GARAGES THAT ARE SEPARATED FROM OTHER BUILDING SHAFTS BY NOT LESS THAN 2 HR FIRE RESISTANCE RATED CONSTRUCTION. WALLS SEPARATING DWELLING UNITS OR SLEEPING UNITS, AND OCCUPANCY SEPARATIONS CLASSIFICATION PER IBC 302 1 HR 1 HR EXTERIOR WALL @ TRANSFORMER AND GENERATOR 3 HR NR NOT REQUIRED NA NOT 20 MIN REQUIRED FIRE WALL DESIGN OCCUPANCY LOAD FIRE UP FD FD FD FD FD FD FD FD FD FD FD FD UP EGRESS LEGEND SYMBOL DESCRIPTION COMMON PATH OF TRAVEL: 2 SEPARATE PATHS OF EGRESS TO SEPARATE EXITS 125' MAX GROUP R-2 NFPA 13 OVERALL DIAGONAL DIMENSION DISTANCE BETWEEN EXITS (NONSPRINKLERED > 1/2 OVERALL DIAGONAL DIMENSION) TRAVEL DISTANCE OCCUPANCY MAXIMUM TRAVEL DISTANCE A, E, F-1, I-1, M, R, S-1 B F-2, S-2, U I-2, I-3, I-4 NON-SPRINKLERED SPRINKLERED 200' 250' 200' 300' 300' 400' 150' 200' OCCUPANCY 2 EXITS REQ'D WHEN OCCUPANT LOAD > THAN A, B, E, F, M, U H-4, H-5, I-1, I-3, I-4, R S 49 10 (20 WITHIN R-2 DWELLING UNIT) 29 OCCUPANCY COMMON PATH OF EGRESS A,M,R-1 B,S-2 75' MAX (SPRINKLERED) 100' MAX (SPRINKLERED) ACCESSIBLE ENTRANCE EXIT OCCUPANT LOAD LONGEST DIAGONAL = 274'-11" (1/2 DIAGONAL = 137'-5 1/2") EXIT TRAVEL DISTANCE = 91' - 5" (<300'-0" MAX.) EXIT DISTANCE = 250'-11" MIN. EXIT DISTANCE = 137'-5 1/2" EXIT TRAVEL DISTANCE = 162' - 10" (<300'-0" MAX.) EXIT TRAVEL DISTANCE = 52' - 1" (<300'-200 0" MAX.) EXIT TRAVEL DISTANCE = 50' - 2" (<300'-200 0" MAX.) EXIT TRAVEL DISTANCE = 50' - 11" (<300'-200 0" MAX.) COMMON PATH OF EGRESS TRAVEL = 99' - 0" UP DN DN UP FD FD FD FD FD FD FD FD FD FD FD FD FD EGRESS LEGEND SYMBOL DESCRIPTION COMMON PATH OF TRAVEL: 2 SEPARATE PATHS OF EGRESS TO SEPARATE EXITS 125' MAX GROUP R-2 NFPA 13 OVERALL DIAGONAL DIMENSION DISTANCE BETWEEN EXITS (NONSPRINKLERED > 1/2 OVERALL DIAGONAL DIMENSION) TRAVEL DISTANCE OCCUPANCY MAXIMUM TRAVEL DISTANCE A, E, F-1, I-1, M, R, S-1 B F-2, S-2, U I-2, I-3, I-4 NON-SPRINKLERED SPRINKLERED 200' 250' 200' 300' 300' 400' 150' 200' OCCUPANCY 2 EXITS REQ'D WHEN OCCUPANT LOAD > THAN A, B, E, F, M, U H-4, H-5, I-1, I-3, I-4, R S 49 10 (20 WITHIN R-2 DWELLING UNIT) 29 OCCUPANCY COMMON PATH OF EGRESS A,M,R-1 B,S-2 75' MAX (SPRINKLERED) 100' MAX (SPRINKLERED) ACCESSIBLE ENTRANCE EXIT OCCUPANT LOAD LONGEST DIAGONAL = 274'-11" (1/2 DIAGONAL = 137'-5 1/2") EXIT DISTANCE = 235'-2" MIN. EXIT DISTANCE = 137'-5 1/2" EXIT TRAVEL DISTANCE = 189' - 6" (<300'-0" MAX.) EXIT TRAVEL DISTANCE = 187' - 3" (<300'-0" MAX.) 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT DN DN FD FD FD FD EGRESS LEGEND SYMBOL DESCRIPTION COMMON PATH OF TRAVEL: 2 SEPARATE PATHS OF EGRESS TO SEPARATE EXITS 125' MAX GROUP R-2 NFPA 13 OVERALL DIAGONAL DIMENSION DISTANCE BETWEEN EXITS (NONSPRINKLERED > 1/2 OVERALL DIAGONAL DIMENSION) TRAVEL DISTANCE OCCUPANCY MAXIMUM TRAVEL DISTANCE A, E, F-1, I-1, M, R, S-1 B F-2, S-2, U I-2, I-3, I-4 NON-SPRINKLERED SPRINKLERED 200' 250' 200' 300' 300' 400' 150' 200' OCCUPANCY 2 EXITS REQ'D WHEN OCCUPANT LOAD > THAN A, B, E, F, M, U H-4, H-5, I-1, I-3, I-4, R S 49 10 (20 WITHIN R-2 DWELLING UNIT) 29 OCCUPANCY COMMON PATH OF EGRESS A,M,R-1 B,S-2 75' MAX (SPRINKLERED) 100' MAX (SPRINKLERED) ACCESSIBLE ENTRANCE EXIT OCCUPANT LOAD LONGEST DIAGONAL = 274'-11" (1/2 DIAGONAL = 137'-5 1/2") EXIT DISTANCE = 235'-2" MIN. EXIT DISTANCE = 137'-5 1/2" EXIT TRAVEL DISTANCE = 124' - 8" (<300'-0" MAX.) EXIT TRAVEL DISTANCE = 126' - 3" (<300'-0" MAX.) 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL 2" U.N.O. EQ EQ 4" TYP 3' - 6" TYP 2" LIGHT SWITCH DIMMER 4' - 0" THERMOSTAT 1' - 4" MIN 2" ELEC. RECEPTACLE / JUNCTION BOX / TELEPHONE / DATA OUTLET 6' - 8" STROBE LIGHT AND HORN HANDLE 4' - 0" FIRE ALARM PULL STATION F.E.C. FINISH FLOOR ACCESSIBILITY NOTES DIMENSIONS AND NOTES ARE TYPICAL THROUGHOUT PROJECT UNLESS NOTED OTHERWISE. 1. DIMENSIONS AND STANDARDS COINCIDE WITH ICC / ANSI A117.1-2003. 2. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST UP UP FD FD FD FD FD FD FD FD FD FD FD FD UP 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 JEFFERSON STREET FIREHOUSE ALLEY CHESTNUT STREET ADJACENT HOTEL PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE TO P.L. 6' - 6" TO P.L. 4' - 7 3/4" TO P.L. 16' - 8 1/4" TO P.L. 24' - 5 5/8" TO P.L. 4' - 2 1/2" TO P.L. 7' - 11 3/4" TO P.L. 2' - 2 7/8" TO P.L. 18' - 8 1/4" TO P.L. 5' - 8 3/4" TO P.L. 21' - 8 1/2" TO P.L. 2 1/4" TO P.L. 5" A.4 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT UP UP FD FD FD FD FD FD FD FD FD FD FD FD UP 4 A200 A200 A200 A200 2 3 1 4 3.7 3 2 1.6 1.3 1 A B C D E F G 1 A250 1 A250 4' - 2" 18' - 4" 36' - 1" 62' - 6" 19' - 1" 19' - 1" 16' - 3" 16' - 7" 22' - 5" 40' - 0" 40' - 0" 40' - 0" 40' - 0" 24' - 9 7/8" 1' - 0 1/8" 13' - 2" 3 SPACES 16 SPACES 16 SPACES 11 SPACES 5 SPACES 6 SPACES 5 SPACES POTENTIAL RETAIL/OFFICE FLEX SPACE RAMP DOWN 5" RAMP ON GRADE W/ FIBROUS REINFORCING RE. STRUCT. VAN VAN PUBLIC PARKING RETAIL/OFFICE FLEX SPACE ELEV 3 A250 3 A250 61' - 10" 1.9% 1.9% 5.7% DN 5 UP DN DN UP FD FD FD FD FD FD FD FD FD FD FD FD FD 4 A200 A200 A200 A200 2 3 1 4 3.7 3 2 1.6 1.3 1 A B C D E F G 1 A250 1 A250 11 SPACES 18 SPACES 16 SPACES 9 SPACES 9 SPACES 16 SPACES 19 SPACES 11 SPACES 16' - 7" 22' - 5" 40' - 0" 40' - 0" 40' - 0" 40' - 0" 24' - 9 7/8" 1' - 0 1/8" 13' - 2" 4' - 2" 18' - 4" 36' - 1" 62' - 6" 19' - 1" 19' - 1" 16' - 3" 4 SPACES 4 SPACES 3 A250 3 5 A250 PAY STATION (ALTERNATE) EMERGENCY CALL BOX (ALTERNATE) PAY STATION (ALTERNATE) EMERGENCY CALL BOX (ALTERNATE) A.3 F.6 F.6 A701 2 DN DN FD FD FD FD 4 A200 A200 A200 A200 2 3 1 4 3.7 3 2 1.6 1.3 1 A B C D E F G 1 A250 1 A250 RAMP DOWN 6.67% DN 19 SPACES 16 SPACES 16 SPACES 18 SPACES 11 SPACES 11 SPACES 5 SPACES 9 SPACES 9 SPACES 16' - 7" 22' - 5" 40' - 0" 40' - 0" 40' - 0" 40' - 0" 24' - 9 7/8" 1' - 0 1/8" 13' - 2" 4' - 2" 18' - 4" 36' - 1" 62' - 6" 19' - 1" 19' - 1" 16' - 3" 3 A250 3 A250 RAMP UP 6.67% UP 5 PAY STATION EMERGENCY CALL BOX PAY STATION (ALTERNATE) EMERGENCY CALL BOX (ALTERNATE) A.3 F.6 A701 3 A702 3 6" DIA. BOLLARD WS-3 WS-3 2 FD FD FD FD 4 A200 A200 A200 A200 2 3 1 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 PV ARRAY (ALTERNATE) 20'-4" X 150'-6" = 3060 SF PV ARRAY (ALTERNATE) 20'-4" X 150'-6" = 3060 SF A.3 F.6 5 A250 1/2" /12" MIN. 1/2" /12" MIN. 1/2" /12" MIN. 1/2" /12" MIN. 1/2" /12" MIN. A250 6 6" DOWNSPOUT AND SCUPPER TO MATCH METAL PANEL 6" DOWNSPOUT AND SCUPPER TO MATCH METAL PANEL A.4 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" G F E D C B A 1 A250 1 A250 METAL GRATE W/ GALVANIZED STEEL FRAME BRICK VENEER INTEGRAL COLOR PRECAST CONCRETE SPANDREL METAL GRATE WITH GALVANIZED STEEL FRAME ALUMINUM STOREFRONT CONCRETE PLANTERS W/ PREFINISHED GALVANIZED FLOWERS REF. LANDSCAPE METAL COPING GALV. STEEL 'C' CHANNEL CONTINUOUS STEEL PLATE FIN A309 1 A308 1 F.6 A.3 GALVANIZED STEEL C CHANNEL CANOPY W/ METAL GRATE INFILL PANELS T.O. PANEL EL = 103' - 9" T.O. PANEL EL = 107' - 0" T.O. PANEL EL = 129' - 5" T.O. PANEL EL = 118' - 9" T.O. PANEL EL = 129' - 5" 2 A250 2 A250 CONTINUOUS PRECAST REVEAL PV ARRAY BEYOND (ALTERNATE) D2 DASHED LINE OF ROOF BEYOND DASHED LINE OF BRICK LEDGE BELOW - RE: STRUCT E1 F1 E1 F1 E1 F1 A1 C C C C C C A2 A2 A2 E2 F2 E3 F3 E3 F3 E3 G H H H H H H H H H H H H H G OVERFLOW DRAIN DOWNSPOUT NOZZLE - CENTER ON BRICK PILASTER, TYP. A.4 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 1 1.3 1.6 2 3 3.7 4 3 A250 3 A250 5 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" A B C D E F G 1 A250 1 A.3 A250 F.6 2 A250 2 A250 A250 4 CABLE GUARDS BETWEEN SPANDREL PANELS - 42" MIN AFF WITH 4" MAX SPACING, TYP. - RE. STRUCT. A.4 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 1 1.3 1.6 2 3 3.7 4 3 A250 3 A250 5 3' - 0" CLR. 3' - 0" CLR. LEVEL 01 100' - 0" WS-5 SLOPE SLOPE CONCRETE WALL BEYOND SIM. LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" 4 A301 3 A301 5 A301 7 A301 8 A301 6 A301 2 A301 PRECAST COLOR 1 PRECAST COLOR 2 ONLY IN AREAS BEHIND SCREENS 1/2" PRECAST REVEAL - REFER 8A606 / A511 5 CANOPY SUPPORTS, RE. STRUCT. WS-1A WS-1B SIM. SIM. 05 12 00.a SIGNAGE TO BE APPROVED EQ EQ 5' - 10" 5' - 7" 8'-4" CLR. VEHICLE CRASH BAR METAL GRATE WITH GALVANIZED STEEL FRAME CONT. STEEL PLATE FIN 03 40 00.a 03 40 00.a 03 40 00.a 1'-1" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-1" 11" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" G A511 1 A604 2 WS-1A WS-1B SIM. SIM. A601 4 T.O. PANEL EL = 129' - 5" A606 11 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 5 4 3.7 2 A302 4 A302 5 A302 6 A302 WS-1A WS-2 WS-1B 3 A302 7 A302 STEEL CANOPY, RE. STRUCT. 03 30 00.0 WS-6 05 12 00.a 03 30 00.c 03 40 00.a 1/2" PRECAST REVEAL - REFER 8 / A606 CAST STONE CAP 03 40 00.a 08 43 13.e 08 43 13.d METAL GRATE WITH GALVANIZED STEEL FRAME TO SUPPORT "GREEN SCREEN" SYSTEM VINES G A601 1 A605 1 A605 2 A605 3 T.O. STEEL EL = 110' - 10 1/2" FINISHED FLOOR EL = 102' - 6" 3.7 G 2 A302 3.7 G 2 A302 A602 4 UP DN UP DN LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 1 1.3 2 A303 3 A303 4 A303 5 A303 6 A303 SIGNAGE TO BE APPROVED GALV. STEEL CANOPY, RE. STRUCT. 03 30 00.0 08 43 13.e 08 43 13.d WS-3 T.O. STEEL EL = 111' - 8" A605 3 A605 1 A605 4 A.4 WS-3 WS-3 WS-3 A605 5 A601 1 T.O. STEEL EL = 111' - 8" A605 1 A605 2 A605 3 A.4 WS-3 WS-3 1 1.3 2 A303 3 A602 A303 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" F G 2 A304 3 A304 4 A305 1 A305 2 A305 3 A305 F.6 SIGNAGE TO BE APPROVED WS-1A STEEL CANOPY, RE. STRUCT. 03 40 00.a 03 40 00.a 03 30 00.n 08 43 13.e 08 43 13.d 9 A606 T.O. PARAPET CAP EL = 143' - 8" WS-3 WS-2 WS-1B 05 12 00.a A601 1 T.O. STEEL EL = 110' - 10 1/2" A605 2 A605 1 A605 3 T.O. STEEL EL = 110' - 10 1/2" A605 1 A605 3 A605 4 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT UP UP F 2 G A304 3 A304 4 A305 F.6 A603 5 A603 1 A603 3 F 2 G A304 3 A304 4 A305 F.6 35' - 0 3/8" 8' - 7 1/8" 3' - 10 1/2" A603 2 A603 4 A603 6 A603 10 F 2 G A304 3 A304 4 A305 F.6 A603 2 A603 7 PRECAST PARAPET CAP BELOW GALVANIZED STEEL PLATE FIN BELOW A603 10 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" A605 5 A601 3 ELEVATOR PIT LADDER LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" F 3 A306 2 A306 4 A306 5 A306 6 A306 WS-1A WS-1B WS-2 05 12 00.a 03 40 00.a 1/2" PRECAST REVEAL - REFER 05 50 00.f 8A606 / CAST STONE CAP 1'-0" 1'-0" 1'-0" 1'-1" 4 5 WS-1A WS-1B WS-1B WS-5 T.O. STEEL EL = 114' - 4" WS-2 A601 4 SIM. A605 6 A605 7 A604 3 SIM. A605 8 A604 5 A511 1 TYP. T.O. PANEL EL = 129' - 5" T.O. PARAPET CAP EL = 124' - 6" T.O. SILL EL = 106' - 4" T.O. PANEL EL = 118' - 9" 4 5 WS-1B WS-1A WS-5 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" D 2 A307 3 A307 6 A307 7 A307 8 A307 5 A307 4 A307 WS-1A WS-2 WS-2 WS-1B WS-1B 05 12 00.a 03 40 00.a 05 12 00.a 1/2" PRECAST REVEAL - REFER 8 / A606 4 5 A604 5 A605 8 A511 1 TYP. A601 4 A605 6 A605 7 A604 3 SIM. T.O. PANEL EL = 129' - 5" T.O. PARAPET CAP EL = 124' - 6" T.O. SILL EL = 106' - 4" T.O. PANEL EL = 118' - 9" T.O. STEEL EL = 114' - 4" FINISHED FLOOR EL = 102' - 7" 4 5 A604 5 A601 4 A511 1 TYP. LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 2 A308 3 A308 4 A308 5 A308 A.3 03 30 00.0 03 40 00.a 08 43 13.d 08 43 13.e STEEL CANOPY, RE. STRUCT. 1.3 1 A.4 A601 1 A605 1 A605 2 A605 3 1 2 A308 A.4 1 2 A308 A602 7 SIM. A.4 1 2 A308 A602 7 SIM. A.4 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" F 2 A309 4 A309 3 A309 7 A309 6 A309 5 A309 WS-1B WS-1A WS-2 WS-1B 05 12 00.a 03 40 00.a 1/2" PRECAST REVEAL - REFER 8 / A606 METAL GRATE WITH GALVANIZED STEEL FRAME CAST STONE CAP METAL GRATE WITH GALVANIZED STEEL FRAME PRECAST COLOR 2 ONLY BEHIND METAL SCREENS 1 A511 1 TYP. A606 1 A606 2 A601 4 SIM. T.O. PANEL EL = 129' - 5" T.O. STEEL EL = 112' - 4 1/2" T.O. PARAPET CAP EL = 119' - 6" T.O. PANEL EL = 118' - 9" T.O. SILL EL = 103' - 0" T.O. PANEL EL = 103' - 9" A604 5 SIM. 1 A601 4 SIM. T.O. PANEL EL = 129' - 5" T.O. PARAPET CAP EL = 119' - 6" T.O. PANEL EL = 118' - 9" SECTION 4" TYP. 04 20 00.a MASONRY VENEER 07 21 00.a 1-1/2" BOARD INSULATION STUD 6" STUD 3 5/8" F.O. STUD 6 3/4" 07 25 00.a WEATHER/AIR BARRIER 04 20 00.d MASONRY ANCHORAGE 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 07 21 00.b R-13 BATT INSULATION (3-1/2") 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 07 21 00.a 1-1/2" BOARD INSULATION 07 21 00.b R-13 BATT INSULATION (3-1/2") 07 25 00.a WEATHER/AIR BARRIER 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. PLAN 1" AIRSPACE, TYP. 1" AIRSPACE, TYP. 05 40 00.a 3-5/8" METAL STUD FRAMING, RE: STRUCT. 04 20 00.a MASONRY VENEER 05 40 00.a 3-5/8" METAL STUD FRAMING, RE: STRUCT. F.O. STUD 6 3/4" STUD 3 5/8" STUD 6" NOTE: NO RIGID OR BATT INSULATION AT SIM. CONDITION 07 25 00.a WEATHER/AIR BARRIER PLAN SECTION 07 25 00.a WEATHER/AIR BARRIER 07 42 13.a INTERLOCKING METAL WALL PANEL 07 42 13.a INTERLOCKING METAL WALL PANEL 03 30 00.c CONC. WALL, RE: STRUCT 03 30 00.c CONC. WALL, RE: STRUCT 8" 1 7/8" 05 40 00.c 7/8" METAL FURRING CHANNEL 05 40 00.c 7/8" METAL FURRING CHANNEL 8" 1 7/8" NOTE: CMU AT SIM. CONDITION SECTION 4" 04 20 00.a MASONRY VENEER 07 21 00.a 1-1/2" BOARD INSULATION STUD 6" F.O. STUD 6 3/4" 07 25 00.a WEATHER/AIR BARRIER 04 20 00.d MASONRY ANCHORAGE 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 07 21 00.b R-13 BATT INSULATION (3-1/2") 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 07 21 00.a 1-1/2" BOARD INSULATION 07 21 00.b R-13 BATT INSULATION (3-1/2") 07 25 00.a WEATHER/AIR BARRIER 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. PLAN SECTION 07 21 00.a 1-1/2" BOARD INSULATION 07 25 00.a WEATHER/AIR BARRIER 07 21 00.b R-13 BATT INSULATION (3-1/2") 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 03 45 00.d PRECAST CONCRETE ATTACHMENT 6" F.O. STUD 5 1/8" 1" AIR SPACE, TYP. 2" 2" 03 45 00.d PRECAST CONCRETE ATTACHMENT 6" F.O. STUD 5 1/8" 1" AIRSPACE, TYP. SECTION 04 20 00.l CONCRETE MASONRY UNIT 2'-10" T.O. BASE CONCRETE BASE AT SIM. CONDITION PLAN 04 20 00.l CONCRETE MASONRY UNIT FINISHED FLOOR 7 5/8" ALIGN OUTSIDE WALL 7 5/8" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 SHEETNOTES: 1.ALL DIMENSIONS PROVIDED ARE TO ROUGH OPENINGS (R.O.) ACTUAL WINDOW SIZES SHALL BE DETERMINED BY WINDOW MFGR, TAKING INTO ACCOUNT THEIR REQ'D SHIM SPACE. SUBMIT FRAME SIZES & R.O. FOR REVIEW PRIOR TO FABRICATION. 2. VERIFY ALL DIMENSIONS IN FIELD. 3. ALL STOREFRONTS SHOWN ARE USING 6.5" DEEP FRAMES. 4.REFER TO DETAIL FOR METAL INSERTS GLAZING LEGEND: T = TEMPERED GLASS M = METAL INSERT (REPLACING GLASS ) 3A606 / 33' - 4" 4'-11 1/4" 2'-0" 4'-11 1/4" 11' - 10 1/2" T T T T T T T T T T T T T T T T T T T T T T T T T T T M M M M M 11 3/4" 4'-11 1/4" 1'-6" 3'-3 1/2" 1'-0" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-1" 1'-1 1/4" 1/2" 2'-4" 10 1/2" 4'-8" 1'-11 1/4" 33' - 4" 1'-11 1/4" 4'-8" 10 1/2" 2'-4" 1'-1 1/4" 4'-11 3/4" 1'-6" 3'-1" 1'-1 1/4" 4'-11 3/4" 1'-6" 3'-3 1/2" 1'-0" 11 3/4" 2'-0" 6'-0 1/4" 2'-0" 6'-0 1/4" T T T T T T T C A2 A1 LEVEL 01 100'-0" 2' - 7" 25' - 1" 5' - 5 1/2" EQ EQ EQ EQ 5' - 5 1/2" 3' - 10" 23' - 10" 19' - 4" 8' - 4" EQ EQ 5' - 5 1/2" 8' - 2" 1' - 0" 2' - 0" 1' - 0" 10' - 7" 1' - 4" 1' - 0" 2' - 0" 1' - 0" 10' - 7" 1' - 4" 1'-4" 1" 1" 10'-4 1/4" 1" 7'-11 1/4" 1" 1" 2'-4 5/8" 2'-4 5/8" 1" 1" 2'-4 5/8" 2'-4 5/8" 1" 1" 10'-4 1/4" 1" 7'-6 5/8" 1" 1" 1" 2'-4 5/8" 2'-4 5/8" 1" 1" 2'-4 5/8" 2'-4 5/8" 1" 1" 6'-7 5/8" 1" 1" 2'-4 5/8" 2'-4 5/8" 1" F3 F2 F1 E3 E2 E1 2' - 9 1/2" 2' - 9 1/2" 2' - 9 1/2" 2' - 9 1/2" 2' - 9 1/2" 2' - 9 1/2" 1' - 7" 28' - 4" 6' - 4" 1' - 0" 4' - 8" 1' - 0" 9' - 7" 1' - 0" 3' - 7" 3' - 3" 26' - 8" 5' - 1" 1' - 0" 4' - 8" 1' - 0" 9' - 7" 1' - 0" 3' - 7" 6' - 1" 23' - 10" 2' - 4" 1' - 0" 4' - 8" 1' - 0" 9' - 7" 1' - 0" 3' - 7" 1' - 7" 28' - 4" 6' - 4" 1' - 0" 4' - 8" 1' - 0" 9' - 7" 1' - 0" 3' - 7" 3' - 3" 26' - 8" 5' - 1" 1' - 0" 4' - 8" 1' - 0" 9' - 7" 1' - 0" 3' - 7" 6' - 1" 23' - 10" 2' - 4" 1' - 0" 4' - 8" 1' - 0" 9' - 7" 1' - 0" 3' - 7" H G LEVEL 01 100'-0" 3' - 2" 8' - 0" VARIES 8' - 6" 5' - 6" 4' - 3" 1" 5' - 1" 1" 1" 7' - 7" 1" 1" 3' - 10" 1" 1" 8' - 1" 1" 6'-7" 1'-6" 8'-0" 1'-3" 9'-3" 1" 1" 2'-3 1/2" 1" 2'-3 1/2" 1" 1" 4'-9" 1'-6" 8'-0" 1'-3" 9'-3" 1" A NOTE: SEE DOOR SCHEDULE FOR OVERALL DIMENSIONS AND DETAILS. Finish Floor B C D 10" 4" 4" 4" 10" 4" 4" 4" 4" 4" 8' - 10 3/8" 19' - 0 3/8" 19' - 0 3/8" 8' - 6 3/8" 19' - 0 3/8" 7' - 10 3/8" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:35 AM A520 DOOR & FRAME TYPES & DOOR SCHEDULE 165 CHESTNUT ST FORT COLLINS, CO 80524 07 25 00.c VAPOR RETARDER 03 30 00.h EXPANSION JOINT 07 11 13.a DAMPPROOFING 07 21 00.f FOUNDATION INSULATION BOARD 03 30 00.h EXPANSION JOINT EXT. SLAB ON GRADE, ELEV VARIES, RE. CIVIL CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a 08 43 13.b STOREFRONT SILL EXTRUDED ALUM SILL W/ BACK AND END DAMS, SET IN BED OF SEALANT 08 43 13.c 07 92 00.b CONT. SEALANT CONCRETE STEM WALL, RE: STRUCT. ALGIN SLOPE 1/4" PER FOOT MIN. 07 21 00.f FOUNDATION INSULATION BOARD 07 11 13.a DAMPPROOFING 07 25 00.c VAPOR RETARDER 03 30 00.h EXPANSION JOINT 07 25 00.a WEATHER/AIR BARRIER 05 12 00.e STEEL ANGLE, RE: STRUCT. 07 65 00.0 FLEXIBLE FLASHING OVER ANGLE AND WRAP UNDER SILL CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a 08 43 13.b STOREFRONT SILL 08 43 13.m NON-EXPANDING SPRAY FOAM INSULATION F.O. STUD 3" SEAL MEMBRANE TO FOUNDATION WALL 03 30 00.a CONC. SLAB, RE: STRUCT CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a EXTEND UP WALL UNDER FLASHING 4" MIN 1/4" FIBER REINFORCED ASPHALTIC MEMBRANE 07 54 00.h 04 20 00.j DRAINAGE BOARD 07 65 00.0 FLEXIBLE FLASHING 03 45 00.d PRECAST CONCRETE ATTACHMENT SLOPE GROUT FOR POSITIVE DRAINAGE, TYP. LAP OVER FLEXIBLE FLASHING 4" MIN BEHIND INSUL. WS-6 EXTRUDED ALUM SILL W/ BACK AND END DAMS, SET IN BED OF SEALANT 08 43 13.c T.O. PRECAST EL = 104' - 4" 04 20 00.e WEEP HOLES SLOPE OUT OF WALL @ 24" O.C. ABOVE GRADE 07 65 00.0 FLEXIBLE FLASHING 07 42 13.c INTERLOCKING METAL WALL FLASHING SLOPE CONCRETE FOR POSITIVE DRAINAGE 07 21 00.f FOUNDATION INSULATION BOARD 07 11 13.a DAMPPROOFING 1" TYP. 2"x3"x1/4" GALV. BENT PLATE - MECHANICALLY FASTENED TO HORIZONTAL FIN AT 48" O.C. 4"x3/8" HORIZONTAL GALV. STEEL FIN - REFER ELEVATIONS FOR LOCATIONS 1/2" TYP. 2' - 4" 2' - 11 5/8" 05 12 00.c STEEL COLUMN; RE: STRUCT. 03 40 00.a PRECAST CONCRETE PANEL 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT AT VERTICAL JOINTS - BOTH SIDES, TYP. SIM. WS-1B SIM. WS-1A SIM. WS-1B GALV. METAL CANOPY BELOW 05 12 00.c STEEL COLUMN; RE: STRUCT. 03 40 00.a PRECAST CONCRETE PANEL 2"x3"x1/4" GALV. BENT PLATE - MECHANICALLY FASTENED TO UNDERSIDE OF HORIZONTAL FIN AT 48" O.C. 4"x3/8" HORIZONTAL GALV. STEEL FIN - REFER ELEVATIONS FOR LOCATIONS 1" TYP. 1/2" TYP. GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 05 12 00.a 1" MIN. OVERLAP 3/8" 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT AT VERTICAL JOINTS BOTH SIDES, TYP. SIM. WS-1B SIM. WS-1B SIM. WS-1B SIM. WS-1A STUCCO SYSTEM 09 22 00.0 WEATHER/AIR BARRIER 07 25 00.a 5/8" TYPE X EXTERIOR GYP SHEATHING 09 21 16.k 5/8" AIR SPACE 2' - 4" CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a BELOW METAL CANOPY BELOW 03 40 00.a PRECAST CONCRETE PANEL 05 12 00.c STEEL COLUMN; RE: STRUCT. CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a SIM. WS-1B SIM. WS-1A CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a INTERLOCKING METAL WALL PANEL FASTENERS WS-3 07 42 13.b WS-3 05 12 00.d STEEL BEAM, RE: STRUCT. WS-3 08 43 13.d STOREFRONT TYPICAL MULLION CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a INTERLOCKING METAL WALL PANEL FASTENERS 07 42 13.b CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a 3" CONCRETE WALL RE: STRUCT. WS-1A WS-6 1" AIR SPACE 3/8" 1" AIR SPACE 5 1/4" CUT BRICK TO ALLOW FOR CONT. 1" AIR SPACE WS-1A TOP OF CHANNEL BELOW WS-2 STEEL PLATE WELDED TO CHANNEL ENDS, BOTH SIDES, TYP. 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT 1" AIR SPACE INTERIOR EXTERIOR NO PANEL AT SIM. CONDITION 03 40 00.a PRECAST CONCRETE PANEL CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a 03 30 00.c CONC. WALL, RE: STRUCT WS-1A 1/2" 4" RETAIL INTERIOR ELEVATOR SHAFT INTERIOR EXTERIOR WS-3 WS-1A WS-3 07 42 13.b INTERLOCKING METAL WALL PANEL FASTENERS 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT 07 25 00.a WEATHER/AIR BARRIER EXTERIOR GARAGE INTERIOR A606 5 A606 6 SIM. WS-1B BRICK WALL BEYOND GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 05 12 00.a 05 12 00.e STEEL ANGLE, RE: STRUCT. 05 12 00.d STEEL BEAM, RE: STRUCT. 03 40 00.a PRECAST CONCRETE PANEL WS-2 SIM. WS-1A SIM. WS-1B A606 7 A606 10 SIM. 03 40 00.a PRECAST CONCRETE PANEL 05 12 00.e STEEL ANGLE, RE: STRUCT. 05 12 00.d STEEL BEAM, RE: STRUCT. 05 31 23.0 STEEL ROOF DECK, RE: STRUCT. LEVEL 02 115' - 0" 07 62 00.a PREFINISHED METAL FLASHING CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a WS-1B WS-2 1/2" TYP. 1 1/2" AIR SPACE GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 05 12 00.a 03 30 00.a CONC. SLAB, RE: STRUCT 03 40 00.a PRECAST CONCRETE PANEL 09 22 00.j CASING BEAD W/WEEPS 07 25 00.a WEATHER/AIR BARRIER LAP OVER METAL FLASHING REFER STRUCTURAL PLAN FOR INSULATED SLAB LOCATIONS A605 8 WS-1A WS-5 WS-2 2x3x8 ANGLE AT 48" O.C. INTERNAL GUTTER SLOPE TO ROOF DRAIN 07 65 00.0 FLEXIBLE FLASHING 03 45 00.b PRECAST CONCRETE WALL CAP 07 54 00.d TPO MEMBRANE CONTINUE OVER ROOF EDGE & TURN DOWN WALL A606 10 05 12 00.d STEEL BEAM, RE: STRUCT. 05 51 00.a METAL STAIRS GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 05 12 00.a 05 50 00.h GALVANIZED METAL GRATE 05 12 00.e STEEL ANGLE, RE: STRUCT. LEVEL 02 115' - 0" 08 80 00.b SPANDREL GLASS 05 12 00.d STEEL BEAM, RE: STRUCT. 05 12 00.e STEEL ANGLE, RE: STRUCT. CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a EXTRUDED ALUM SILL W/ BACK AND END DAMS, SET IN BED OF SEALANT 08 43 13.c 08 43 13.a STOREFRONT HEAD 08 43 13.d STOREFRONT TYPICAL MULLION 6 1/2" 07 92 00.b CONT. SEALANT ROOF 136' - 10" 07 62 00.a PREFINISHED METAL FLASHING 07 54 00.d TPO MEMBRANE LAP MEMBRANE, SEAL AND HEAT WELD PER ROOFING MFR'S RECOMMENED INSTALLATION INSTRUCTIONS 05 31 23.0 STEEL ROOF DECK, RE: STRUCT. 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 08 80 00.b SPANDREL GLASS REFER STOREFRONT TYPES FOR LCOATIONS STOREFRONT TYPICAL MULLION WITH MULLION CAP 08 43 13.e 08 80 00.b SPANDREL GLASS REFER STOREFRONT TYPES FOR LCOATIONS PAINTED WHITE WHEN BEHIND SPANDREL PANEL, TYP. 05 12 00.d STEEL BEAM, RE: STRUCT. 05 12 00.c STEEL COLUMN; RE: STRUCT. 06 10 00.a BLOCKING AS REQ'D SLOPE 07 92 00.b CONT. SEALANT 07 62 00.u CONT. METAL CLEAT , BEYOND 4 3/4" 1/2" TYP. ALIGN B.O. BRICK W/ B.O. STEEL ANGLE, TYP. CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a 08 43 13.a STOREFRONT HEAD 08 51 13.d NON-EXPANDING SPRAY FOAM INSULATION 05 12 00.e STEEL ANGLE, RE: STRUCT. 07 65 00.0 FLEXIBLE FLASHING 04 20 00.e WEEP HOLES SLOPE OUT OF WALL @ 24" O.C. ABOVE GRADE MCNICOLS WELDED BAR GRATING 4" X 2" X 1/8" TUBE STEEL FRAME 1.5"x2"x1/4" ANGLE TO RUN LENGTH OF GRATING WS-1B 2" WS-2 07 62 00.a PREFINISHED METAL FLASHING 07 65 00.0 FLEXIBLE FLASHING 07 92 00.b CONT. SEALANT 09 22 00.j CASING BEAD W/WEEPS 1" MCNICOLS WELDED BAR GRATING 4" X 2" X 1/8" TUBE STEEL FRAME 1.5"x2"x1/4" ANGLE TO RUN LENGTH OF GRATING 1/2" MIN. LIPPED BRICK ALIGN B.O. BRICK W/ B.O. STEEL ANGLE, TYP. WS-2 WS-1B 09 22 00.i CASING BEAD CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 05 12 00.a 07 65 00.0 FLEXIBLE FLASHING 04 20 00.e WEEP HOLES 04 20 00.g MORTAR NET SLOPE OUT OF WALL @ 24" O.C. 07 25 00.a WEATHER/AIR BARRIER LAP OVER FLEXIBLE FLASHING 4" 05 12 00.e STEEL ANGLE, RE: STRUCT. 07 42 64.d COMPOSITE ALUMINUM WALL PANEL 08 43 13.0 ALUMINUM FRAMED STOREFRONTS 1/2" 1/2" 04 20 00.a MASONRY VENEER 07 21 00.a 1-1/2" BOARD INSULATION 07 25 00.a WEATHER/AIR BARRIER 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. 04 20 00.d MASONRY ANCHORAGE 07 21 00.b R-13 BATT INSULATION (3-1/2") 1/2" TYP. 6" 5/8" 1 1/2" 1 1/2" AIR SPACE 3 5/8" WS-1B SIM. WS-1B GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 05 12 00.a SIM. W-2 05 12 00.d STEEL BEAM, RE: STRUCT. 05 12 00.e STEEL ANGLE, RE: STRUCT. DN UP DN UP 3.7 F G F.6 4 A701 5 A701 10 TREADS @ 11" = 9' - 2" 4' - 2" 9 TREADS @ 11"= 8' - 3" 4' - 5 1/2" 8 1/2" 4' - 5 1/2" 11' - 0 1/2" CLR. 6'-4 1/8" STANDPIPE LOCATION 7'-6" CLR. ELEV. STAIR 01 3.7 F G F.6 4 A701 5 A701 7' - 6 1/8" 8 TREADS @ 11"= 4' - 2" 7' - 4" 4' - 5 1/2" 8 1/2" 4' - 5 1/2" 11' - 0 1/2" CLR. STANDPIPE LOCATION 6'-4 1/8" F.E.C. DOWNSPOUT DOWNSPOUT 7'-6" CLR. ELEV. ELEV. CONTROL ROOM STAIR 01 3.7 F G F.6 4 A701 5 A701 5 TREADS @ 11" = 3' - 8" 12 TREADS @ 11" = 8' - 3" UP DN UP DN 1.3 1 4 A702 11" 11 TREADS @ 11" = 10' - 1" 4' - 8" 4' - 5 1/2" 5" 4' - 5 1/2" 6" STANDPIPE LOCATION A.4 1.3 1 4 A702 1' - 7" 10 TREADS @ 11" = 9' - 2" 11" 9 TREADS @ 11" = 8' - 3" 4' - 8" 4' - 5 1/2" 5" 4' - 5 1/2" 6" STANDPIPE LOCATION A.4 TYP 1' - 0" TYP 1' - 0" 1.3 1 4 A702 1' - 7" 10 TREADS @ 11" = 9' - 2" 4' - 8" 4' - 5 1/2" 5" 4' - 5 1/2" 6" STANDPIPE LOCATION A.4 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 1.3 1 1 A702 2 A702 3 A702 11 EQ RISERS = 6' - 2" 10 EQ RISERS = 4' - 6" PTD 1-1/2" O.D. STL RAIL. RE: ROOM FINISH SCHEDULE PTD 1/2" STL ROD PICKETS. RE: ROOM FINISH SCHEDULE PTD 1-1/2" O.D. RAW TUBE STL RAILS W/ CLEAR SEALER, UNO. PTD 1-1/2" O.D. TUBE STL RAILS. RE: ROOM FINISH SCHEDULE STEEL CHANNELS, PTD. (TYP) FINISH FLOOR RE: ROOM FINISH SCHEDULE PTD STEEL CHANNEL STRINGER; PAINT ALL EXPOSED STEEL, TOP & BOTTOM 3' - 6" MIN 3' - 0" 3 7/8" MAX 3 7/8" MAX 3'-0" STEEL PLATES, PTD. (TYP) MAX 3 7/8" CONCRETE WALL LOCATION PER STRUCTURAL STOREFRONT LOCATION PER PLANS 3' - 6" 3' - 6" MIN 3' - 0" PTD 1-1/2" TUBE STL SUPPORT PLACED AT EACH END OF GUARDRAIL LENGTH & CENTER. RE: ROOM FINISH SCHEDULE PTD 1/2" STL ROD PICKETS RE: ROOM FINISH SCHEDULE PTD 1 1/2" TUBE STL RAIL RE: ROOM FINISH SCHEDULE PTD 1-1/2" O.D. STEEL RAIL RE: ROOM FINISH SCHEDULE PTD STL CHANNEL STRINGER RE: ROOM FINISH SCHEDULE (PAINT ALL EXPOSED, TOP & BOTTOM) A703 5 2" 3 1/4" EQ EQ 1 1/2" RE: STAIR SECTIONS 7" MAX. RE: STAIR PLANS 1" 11" MIN. SITE C.I.P. CONCRETE TREADS MC 12x10.6 STRINGER, RE: STRUC. - PTD (TYP.) Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:20 PM S-000 COVER 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 A. INTERNATIONAL BUILDING CODE (IBC 2012) B. SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (AISC 360-10) MEMBER DESIGN BASIS IS LOAD AND RESISTANCE FACTOR DESIGN (LRFD) CONNECTION DESIGN BASIS IS LOAD AND RESISTANCE FACTOR DESIGN (LRFD) C. BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-11) D. BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-11/ASCE5-11/TMS 402-11) E. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE7-10) 1. GOVERNING DESIGN CODES: 01-GENERAL REQUIREMENTS A. SEE "STATEMENT OF SPECIAL INSPECTIONS" FOLLOWING GENERAL NOTES FOR INSPECTION REQUIREMENTS. 2. SPECIAL INSPECTION REQUIREMENTS AND QUALITY CONTROL: A. DEFERRED SUBMITTALS ARE REQUIRED FOR THE FOLLOWING ITEMS. THE CONTRACTOR SHALL SUBMIT COPIES OF THESE ITEMS TO THE BUILDING DEPARTMENT AFTER REVIEW BY THE ARCHITECT AND/OR ENGINEER OF RECORD: a. PRECAST CONCRETE FRAMING b. PRE-ENGINEERED METAL STAIRS c. EXTERIOR CLADDING 3. DEFERRED SUBMITTALS: A. BUILDING CONSTRUCTION TYPE: TYPE 1-B B. FIRE RESISTIVE RATINGS: ROOF CONSTRUCTION: 1 HOURS FLOOR CONSTRUCTION: 2 HOURS STRUCTURAL FRAME: 2 HOURS C. RESTRAINED CONSTRUCTION: THE BUILDING SUPERSTRUCTURE INCLUDING ROOF AND FLOOR CONSTRUCTION IS CONSIDERED RESTRAINED PER THE DEFINITION OF RESTRAINED CONSTRUCTION GIVEN IN ASTM E119, APPENDIX X3, TABLE X3.1: II. CONCRETE FRAMING - ALL TYPES OF PREFABRICATED FLOOR OR ROOF SYSTEMS WITH CONTINUOUS STRUCTURAL CONCRETE TOPPING. III. CONCRETE FRAMING - ALL TYPES OF PREFABRICATED ROOF SYSTEMS WHERE THE SPACE BETWEEN THE ENDS OF THE PRECAST UNITS AND VERTICAL FACE OF SUPPORTS DOES NOT EXCEED 0.25% OF THE MEMBER LENGTH. UNRESTRAINED CONSTRUCTION IS NOTED ON THE PLANS.. E. COMPONENT FIRE RATING ASSEMBLIES: 4. BUILDING CONSTRUCTION INFORMATION: STRUCTURAL COMPONENT OR ASSEMBLY DESCRIPTION REQUIRED FIRE RATING MINIMUM SIZE OR THICKNESS REQ'D. PROVIDED CONCRETE COVER TO REINFORCING UL ASSEMBLY NUMBER RESTRAINED/ UNRESTRAINED REMARKS CONCRETE TYPE PRESTRESSED STEEL REINFORCING MILD STEEL REINFORCING ACTUAL SIZE OR 14-CONVEYING EQUIPMENT 22, 23, 26-MECHANICAL AND ELECTRICAL TRADES 1. ELEVATORS: 1. PRECEDENCE: 2. COORDINATION: 3. EQUIPMENT: 4. SLEEVES AND CORE DRILLING: (CONCRETE ON METAL DECK) 5. CORE DRILLING: (PRECAST CONCRETE) 6. ELECTRICAL CONDUIT: (CONCRETE ON METAL DECK) 7. ELECTRICAL CONDUIT: (PRECAST CONCRETE) 8. SUPPORT OF EQUIPMENT: 9. PRE-POUR OBSERVATION: A. THE ELEVATOR MACHINE ROOM FLOOR, ELEVATOR HOISTWAYS, ELEVATOR PITS, FLOOR AND WALL BLOCKOUTS WERE DESIGNED USING INFORMATION OBTAINED FROM DRAWINGS, SKETCHES AND DESIGN DATA SUPPLIED BY KONE DATED 03/31/16. THE ACCURACY AND COMPLETENESS OF THE INFORMATION RECEIVED IS THE RESPONSIBILITY OF THE ELEVATOR CONSULTANT AND MANUFACTURER. B. DOCUMENTATION: REACTIONS FROM ELEVATOR EQUIPMENT ON MACHINE ROOM FLOOR, ELEVATOR PITS AND SUPPORT BEAMS WERE PROVIDED BY OTHERS AND ARE SHOWN ON THE DRAWINGS FOR INFORMATION ONLY. C. DIVIDER BEAMS: PROVIDE DIVIDER BEAMS AS SHOWN ON THE DRAWINGS. PROVIDE ADDITIONAL DIVIDER BEAMS AS REQUIRED TO SUPPORT GUIDE RAILS BETWEEN FLOORS IF VERTICAL DISTANCE BETWEEN DIVIDER BEAMS SHOWN EXCEEDS MAXIMUM DISTANCE ALLOWED. D. HOIST BEAMS: IF HOIST BEAMS ARE REQUIRED BY THE ELEVATOR MANUFACTURER AND ARE NOT SHOWN ON THE STRUCTURAL DRAWINGS, PROVIDE HOIST BEAMS AT TOP OF ELEVATOR SHAFTS AND CONNECT TO ADJACENT STRUCTURAL FRAMING. SUBMIT SHOP DRAWINGS OF HOIST BEAM FRAMING FOR REVIEW AND APPROVAL PRIOR TO BEAM INSTALLATION. E. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY PURCHASED ELEVATOR EQUIPMENT AGAINST THE INFORMATION SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING, BUT NOT LIMITED TO, EQUIPMENT LOCATION, SIZE, LOADS, OPENINGS, HOISTWAY AND PIT REQUIREMENTS AND SUPPORT REQUIREMENTS. REPORT DIFFERENCES TO THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH THE WORK. F. REDESIGN: IF A REVIEW OF THE ELEVATOR SUBMITTAL REVEALS REDESIGN OF THE MACHINE ROOM FLOOR, HOISTWAY, PIT OR SUPPORT BEAMS IS REQUIRED, THE CONTRACTOR SHALL PROVIDE COMPENSATION TO THE STRUCTURAL ENGINEER FOR THE REDESIGN EFFORT. G. MODIFICATIONS: NO MODIFICATIONS TO THE ELEVATOR MACHINE ROOM FLOOR, HOISTWAY, PIT OR SUPPORT BEAMS TO ACCOMMODATE PURCHASED EQUIPMENT WILL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION FROM THE ARCHITECT AND ENGINEER. H. LIMITATIONS: ELEVATOR CONSTRUCTION INFORMATION SHOWN ON THE STRUCTURAL DRAWINGS IS LIMITED TO THE FOLLOWING ITEMS: 1. ELEVATOR PITS INCLUDING SUMP PIT AND ELEVATOR DIVIDER BEAMS 2. MACHINE ROOM CONSTRUCTION: FLOOR AND ROOF CONSTRUCTION, MACHINE BEAMS AND HOIST BEAMS. 3. ELEVATOR SHAFT CONSTRUCTION: SHAFT OPENINGS IN FLOOR AND ROOF LEVELS INCLUDING EDGE FRAMING, GUIDE RAIL SUPPORT FRAMING AT FLOORS AND BETWEEN FLOORS WHERE FLOOR TO FLOOR DISTANCES EXCEED 14'-0" AND SUPPORT OF ELEVATOR HOIST MACHINERY LOCATED IN SHAFTS. 4. ALL OTHER EQUIPMENT AND ACCESSORIES REQUIRED FOR ELEVATOR CONSTRUCTION SHALL BE PROVIDED BY THE ELEVATOR MANUFACTURER. A. STRUCTURAL FRAMING COMPONENTS, INCLUDING BUT NOT LIMITED TO STEEL FRAMING, CONCRETE FRAMING, REINFORCING, POST-TENSIONING CABLES AND EMBEDMENTS SHALL TAKE PRECEDENCE OVER MECHANICAL, PLUMBING AND ELECTRICAL (MEP) ITEMS. STRUCTURAL FRAMING COMPONENTS SHALL NOT BE MOVED, ADJUSTED OR OTHERWISE MODIFIED FROM THE STRUCTURAL DRAWINGS TO ACCOMMODATE OTHER DISCIPLINES WITHOUT APPROVAL FROM THE STRUCTURAL ENGINEER. A. THE GENERAL CONTRACTOR AND MECHANICAL AND ELECTRICAL SUBCONTRACTORS SHALL VERIFY PURCHASED EQUIPMENT AND REQUIRED OPENINGS THROUGH FLOORS, ROOF AND WALLS ARE IN AGREEMENT WITH THE DESIGN INFORMATION SHOWN ON THE DRAWINGS. 1. Inspection of reinforcing steel, including prestressing tendons, and placement. 2. Inspection of reinforcing steel welding in accordance with Table 1705.2.2, Item 2b. 3. Inspection of anchors cast in concrete prior to and during placement of concrete where allowable loads have been increased or where strength design is used. 5. Verifying use of required design mix. 6. At the time fresh concrete is sampled to fabricate specimens for strength tests, perform slump and air content tests, and determine the temperature of the concrete. 7. Inspection of concrete and shotcrete placement for proper application techniques. 8. Inspection for maintenance of specified curing temperature and techniques. 10.Inspect formwork for shape, location and dimensions of the concrete member being formed. 1705.2.2 Steel construction other than structural steel - Provide special inspection per Table 1705.2.2 1705.1.1 Special cases - Perform inspections required by the building official for special cases. TABLE 1705.3 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION - x VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED IBC REFERENCE STANDARD ACI 318: 3.5, 7.1-7.7 1910.4 - - AWS D1.4 - ACI 318: 3.5.2 - x ACI 318: CH. 4, 5.2-5.4 - x 1908.5, 1909.1 - x - - x - - x 1910.9 x - x - 1910.10 9. Erection of precast concrete members. (See Table 1705.2 for steel connections and welds.) ACI 318: CH. 16 ACI 318: 6.1.1 ACI 318: 5.11-5.13 ACI 318: 5.9, 5.10 ASTM C 172 ASTM C 31 ACI 318: 5.6, 5.8 1910.6, 1910.7, 1910.8 1904.2, 1910.2, 1910.3 VERIFICATION AND INSPECTION TASK (with IBC reference, where applicable) CONTINUOUS PERIODIC 1704.2.5 Inspection of fabricators - Inspect structural load-bearing members and assemblies where fabrication is being performed at a fabricator's shop per the special inspection requirements of this schedule. 1704.2.5.1 Fabrication and implementation procedures - Verify fabricator's fabrication and quality control procedures. 1705.2.1 Steel construction - Provide inspections per Table of Minimum Requirements for Inspection of Structural Steel Buildings. 1705.2.2 Steel construction - Inspect welding of cold-formed steel framing members such as studs and joists per Table 1705.2.2. Cold formed metal framing: (Including load-bearing stud wall framing, exterior non-load-bearing stud wall UP FD FD FD FD FD FD FD FD FD FD FD FD UP FD FD 4 4 2 1.6 1.3 1.3 1 1 3.7 3.7 3 A A B B C D E F F G G A.3 26'-2" 12'-10" 1'-11 1/4" 1'-10" 39'-0" 40'-0" 40'-0" 40'-0" 40'-0" 39'-0" 1'-10" 243'-7 1/4" 4'-2" 54'-5" 62'-6" 54'-5" 19'-1" 19'-1" 16'-3" 5 18'-4" 36'-1" 1'-10" 17'-1 3/8" 13'-6 1/2" 25'-5 1/2" F.6 16'-7" 22'-5" 39'-0" 1'-10" 1'-8" 24'-9 7/8" 14'-2 1/8" 3" 16'-3" 1'-8" 1'-10" 18'-4" 18'-4" 1'-0" 1'-6" 2'-1" 18'-6 7/8" 14'-1 1/4" 1'-0 1/2" 1'-0 1/2" 1'-0 1/2" 1'-0 1/2" 13'-6 7/8" 5" S.O.G. 5" S.O.G. DN UP DN UP 115' - 0" 115' - 0" 115' - 0" 115' - 0" 4 4 2 1.6 1.3 1.3 1 1 3.7 3.7 3 A A B B C D E F F G G 1'-1" 9" 1'-0 7/8" TEE STEMS ON SLIDE BRNGS. SPANDREL SUPPORT @ SLIDE BRNG. 10'-0" = 40'-0" 4 SPCS. @ A.3 5 F.6 26'-2" 12'-10" 4'-2" 54'-5" 62'-6" 54'-5" 1'-10" 18'-4" 36'-1" 19'-1" 19'-1" 16'-3" 1'-10" 16'-7" 22'-5" 13'-6 1/2" 25'-5 1/2" 3" 16'-3" 1'-10" 16'-3" 8" 8" 11'-0 1/2" 8" 1'-10" 11" 1'-0" 8" 7'-6" 8" 1" GAP 10'-0" = 40'-0" 4 SPCS. @ 16 TEES @ 10'-0" = 160'-0" 3 @ 9'-1" = 27'-3" 6'-4 1/2" 6'-4 1/2" 1" GAP DEPRESS SLAB SLAB FOR W.P. MEMBRANE & TOPPING SLAB POUR STRIP 9" 1'-1" 9" 9" 9" 1'-1" 1'-1" 9" 2'-1" DN DN FD FD FD FD 8" 4 4 2 1.6 1.3 1.3 1 1 3.7 3.7 3 A A B B C D E F F G G A.3 5 F.6 26'-2" 12'-10" 54'-5" 62'-6" 54'-5" 18'-4" 36'-1" 19'-1" 19'-1" 16'-3" 16'-7" 22'-5" 16'-3" 1'-10" 7'-6 1/2" 10'-9 1/2" 19'-0" 0" EXP. JT. 0" 8'-10" 1'-11" 8" 7'-6" 8" 2'-8 5/8" 16'-6 1/2" 11'-8 1/2" 8'-0" 2'-9" 1'-10" 11" 2 S-411 9" 1'-1" 4 S-301 9" 3" 3 S-301 4 S-301 5 3" S-301 7 S-301 7 S-301 9" 1'-1" 5 S-301 1" GAP 10'-0" = 40'-0" 4 SPCD.@ 10'-0" 8'-0" 16 TEES @ 10'-0" = 160'-0" 3 @ 9'-1" = 27'-3" 6'-4 1/2" 6'-4 1/2" 1" GAP 4 4 2 1.6 1.3 1.3 1 1 3.7 3.7 3 A A B B C D E F F G G A.3 5 F.6 26'-2" 12'-10" 4'-2" 54'-5" 62'-6" 54'-5" 18'-4" 36'-1" 19'-1" 19'-1" 16'-3" 13'-6 1/2" 25'-5 1/2" 16'-7" 22'-5" 16'-3" 8" 18'-4" 19'-0" 8" 8'-10" 1'-11" 8" 7'-6" 8" 28'-3" 10'-9" 11" 2 S-411 3 S-411 3 S-411 16" x 16" CIP PILASTER TYP. 32 PLACES HSS6x6x1/2 COL TYP. 32 PLACES 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" HSS10x6x3/8 W10x22 HSS10x6x3/8 W10x22 1'-10" 39'-0" 40'-0" 40'-0" 40'-0" 40'-0" 39'-0" 1'-10" 241'-8" HSS6x6x1/2 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 GRID GRID GRID GRID GRID SCHEDULE SHAFT DIA. RE: DRILLED PIER #5 AT 24" O.C. U.N.O.; #4 AT 18" O.C. AT 18" Ø PIER 3" CLR. ALIGNMENT BAR DETAIL DRILED PIER REINF. PLACE AT 1/4 POINTS AROUND THE CIRCUMFERENCE AT TOP & BOTTOM AT MID-HEIGHT OF CAGE 3 1/2" 3 1/2" #3 x EXT. 4" 4" ASSUMED TOP OF BEDROCK EL. = 86'-0" FOR BID PURPOSES ONLY. (REFERENCE FIRST FLOOR. EL. = 100'-0") SHEAR RINGS TO BE MADE UNDER DIRECTION OF THE SOILS ENGINEER DRILLED PIER SCHEDULE TYPE DIAMETER BEDROCK REINFORCING VERTICAL REINFORCING 1. DRILLED PIERS SHALL BE CENTERED UNDER COLUMNS AND WALLS UNLESS INDICATED OTHERWISE ON PLANS. 2. DRILLED PIER REINFORCING FABRICATED INTO CAGES SHALL BE TIED ONLY; NO TACK WELDING ALLOWED. 3. IF CASING IS REQUIRED, THE INNER DIAMETER OF THE CASING SHALL MATCH THE SPECIFIED PIER DIAMETER. 4. VERTICAL REINFORCING SHALL NOT BE SPLICED IN THE TOP 30'-0 OF PIER LENGTH. 5. MAXIMUM DRILLED PIER LENGTH = 30xPIER DIAMETER. NOTES: B2 18" 24" 10 FT. REIF. FILL HEIGHT ~TYP. 24" PROVIDE 4-#6X5'-0 DOWELS WITH 2'-6" PROJECTION INTO FOUNDATION WALLS OR GRADE BEAMS WHERE DRILLED PIER REINF. CAN NOT BE EXTENDED U.N.O. ON PLAN OR IN DETAILS NOTES TIE REINFORCING SCHEDULE FOR REQUIRED PENETRATION MINIMUM BEDROCK PENETRATION = 10'-0" ~SEE DRILLED PIER PROJECT VERTICAL DRILLED PIER REINF. INTO CAPS, PILASTERS AND TIE BEAMS ~RE: DETAILS GRID E GRID GRID GRID GRID HSS COL. COL. GRADE BEAM RE: 11/S-201 RE: PLAN 3" RE: PLAN POUR DOWN SLAB @ CAP NO INTERIOR SLAB AT SIM. DRILLED PIER PIER CAP RE: SCHEDULE S-101 PIER T.O. LEDGE RE: PLAN T.O. SLAB/CURB RE: PLAN T.O. DRILLED PIER RE: PLAN 2"2" 6" 2"2" PL 3/4"X6"X1'-2" W/ (2) 3/4"Ø ANCHOR BOLTS W/ 1'-0" EMBEDMENT 6" 4" VOID PIER CAP RE: SCHEDULE SHEET S-101 RE: 11/S-202 FOR REINFORCING 1'-7 1/2" 15'-4" CMU WALL RE: ARCH FOR LOCATION SEE GENERAL NOTER FOR REQUIRMENTS S.O.G. STEP RE: 2/S-201 THICKENED SLAB UNDER CMU WALL RE: 2/S-201 FOR REQUIRMENTS CMU WALL RE: ARCH FOR LOCATION SEE GENERAL NOTES FOR REQUIRMENTS STANDARD HOOK 4" VOID FORM ~ TYP. BAR DEVELOPMENT LENGTH C.I.P. CONCRETE WALL CONCRETE PILASTER RE: PLAN RE: PLAN RE: PLAN CONCRETE GRADE BEAM PILASTER VERT. REINF PILASTER TIES T.O. SLAB RE: PLAN T.O. GRADE BM. RE: PLAN B.O. GRADE BM. T.O. PIER GRID GRID GRID 6" 1' - 6" #4 AT 1'-0" O.C. HOOK INTO ADJACENT RETAING WALL 2" CLR. 1/2" ISOLATION JOINT #4 @ 1'-0" 5" T.O. SLAB RE: PLAN 24" 24" T.O. SLAB RE: PLAN #4 AT 1'-0" O.C. (2) # 4BOTTOM, TYP. (1) # 4 CONT. (1) # 4 CONT. T.O. SLAB RE: PLAN T.O. GRADE BM. RE: PLAN B.O. GRADE BM. T.O. PIER RE: PLAN SLAB-ON-GRADE ~ RE: PLAN SITE PAVING ~ RE: CIVIL (2) #9 T&B STORE FRONT RE: ARCH RE: PLAN 3/8" EXPANSION JOINT MATERIAL, TYP. #4 TIES @ 12" O.C. #5 SKIN REINF. @ 12" O.C. NOTE: 1.) ALL BASE PLATES 1" THICK 2.) ALL ANCHOR BOLTS TO BE 3/4"Ø F1554 W/ ANCHOR RODS W/ 1'-0" MIN EMBEDMENT 3.) 1/4" FILLET WELD ALL COLUMNS W/ 1/4" FILLET WELD ALL AROUND 2" 2" 6" 2" 2" 2" 2" 6" 2" 2" T.O. SLAB RE: PLAN B.O. GRADE BEAM RE: PLAN T.O. DRILLED PIER RE: PLAN CMU WALL RE: ARCH FOR LOCATION SEE GENERAL NOTES FOR REQUIRMENTS CMU CENTERED ON WALL AT SIM. T.O. SLAB RE: PLAN (1) #5 DOWEL@ 48" O.C. RE: 11/S-201 FOR GRID GRID GRID GRID GRID GRID 3'-6" 3" TOPPING 3" WASH 1'-0" 2'-0" TEE T.O. SLAB RE: PLAN FORMED DRIP SPANDREL TO DOUBLE TEE ERECTION CONN. BY P/C MANUF. PRECAST SPANDREL ~ RE: ARCH. FOR PROFILE AND REVEALS PANEL HEIGHT (MIN.) 7'-0" SPANDREL CORBEL BY P/C MFR. TEE STEM MAY BE POCKETED INTO SPANDREL AT P/C MANUF. OPTION. TOOLED JOINT ~ RE: DTL. B, STD. JOINT SEALANT DETAILS W.W.F. ~ TYP. RE: ARCH RE: PLAN 1'-4" BARS CHORD REINF. ~ RE: PLAN OR DETAILS DRAFT ~ RE: ARCH. CONNECTION BY P/C MFR. REFERENCE ELVATION ~ SEE PLANS 3'-6" 3" TOPPING 3" WASH 1'-0" 2'-0" TEE T.O. SLAB RE: PLAN FORMED DRIP 3/8" BEARING PAD PRECAST SPANDREL ~ RE: ARCH. FOR O.F. SURFACE PROFILE HEIGHT (MIN.) 7'-0" SPANDREL P/C DOUBLE TEE STEM NOT SHOWN. COLUMN TO TEE ERECTION CONNECTION BY P/C MFR. 3.7 5 4 3.7 3.7 2 3.7 GRID 2" 3" 2 1/2" 2 1/2" 3/4" GAP (±) P/C TEE FLANGE EMBEDDED PLATE W/ WELDED REINF. SPCG. OF PLATES BY P/C MANUF., NOT TO EXCEED 8'-0" O.C. ~ SEE NOTE* TOOLED JOINT W/ SEALANT ~ RE: STD. JOINT SEALANT DETAILS CONN. PLATE BY P/C MANUF. ~ SEE NOTE* 1/4" 1/2" RET. EA. END DT FLANGE CONN. (MATCHING CAMBER) *NOTE: ALL EMBEDDED PLATES AND CONN. PLATES SHALL BE PAINTED W/ ZINC-RICH PAINT AFTER WELDING. RECTANGULAR BAR. BAR SIZE TO ACCOMMODATE CAMBER DIFF. 1/4" DT FLANGE CONN. (UNEVEN CAMBER) SEE DETAIL ABOVE FOR ADD'L INFO. W.W.F. SHALL BE CONTINUOUS OVER JOINT 3" MIN. 1'-2" 1'-6" TOPPING 3" TOOLED & SEALED JOINTS 7" 7" 18" DP. DOUBLE TEES P/C INVERTED TEE BEAM 6" DAP 18" DP. DOUBLE TEES 6" 2'-5" 1'-9" 8" 3 1/2" CONC. TOPPING 4" INSULATION DRAIN 1/2" W.P. & 1'-6" 3" 3'-6" CURTAIN WALL ~ RE: ARCH T.O. SLAB RE: PLAN CONCRETE SLAB ON METAL DECK ~RE: PLAN 3/16 2-12 L6 TO HSS HSS TO COL L6X3 1/2X5/16XCONT. LLH GRID RE: ARCH HSS TO COL HSS TO COL 3/16 2-12 L3 TO HSS L3X3X3/8XCONT. CURTAIN WALL ~ RE: ARCH HSS TO COL GRID HSS TO COL HSS TO COL 1/4 HSS TO HSS MITER CHANNEL CORNERS 1/4 C8 TO HSS L3X3X3/8 T.O. STEEL RE: PLAN 3/16 2-12 L3 TO HSS HSS TO COL 3/16 HSS TO COL 3/16 HSS TO COL HSS TO COL 3/16 HSS TO COL HSS BEAM RE: PLAN HSS COLUMN RE: PLAN HSS BEAM RE: PLAN HSS8X6X1/2 CHANNEL ~ RE: PLAN HSS BEAM ~ RE: PLAN ANGLE ~ RE: PLAN T.O. STEEL RE: PLAN T.O. STEEL RE: PLAN HSS BEAM ~ RE: PLAN 1" MIN. 4" 3/8" KNIFE PLATE L2X2X3/8X0'-4" 1" MIN. 3/16 UP DN UP DN UP DN 4 3.7 F G 39'-0" 9" 1'-0" 2'-0 1/4" 19'-0" 9'-3" 10'-9" 9" 1'-0" 8'-9" 1'-0" 6" 3" 3'-9 1/4" 1'-0" 15'-5" 8" 6'-0" 8" 4" 5'-9" 8" 8" 6" 2'-8 3/4" 18'-10" 3 1/2" 10'-2 1/2" 100' - 0" 103' - 6" 101' - 10" T.O. WALL T.O. WALL 101' - 10" T.O. WALL T.O. WALL STEP T.O. WALL 1'-3" 1 S-203 101' - 10" T.O. WALL 101' - 10" 18'-4" 5'-11 1/2" 8" 11'-8 1/2" 8" 8" 97' - 6" T.O. MATT T.O. WALL 102' - 6" 1/2" STEP T.O. WALL STEP B.O. WALL STEP B.O. WALL 104' - 9" 102' - 5" T.O. LEDGE T.O. CURB 7 S-202 GRID Level 3 125' - 8" Level 2 115' - 0" Level 1 100' - 0" F E D C B 101' - 5" 102' - 5" 103' - 5" 104' - 5" 105' - 5" 106' - 5" TYP. P/C LITE WALL DIMS. 2'-0" 6'-0" 4'-0" 6'-0" 4'-0" 6'-0" 4'-0" 6'-0" 2'-0" 5'-0" 15 SP. @ 10'-0" = 150'-0" 5'-0" 40'-0" 40'-0" 40'-0" 40'-0" 160'-0" 3 S-411 106' - 3" 8" 4" 24" SQ. COL. TYPICAL LITE WALL PANEL T.O.W. T.O.W. T.O.W. T.O.W. T.O.W. T.O.W. T.O.W. T.O.W. 99' - 7" T.O.W. T.O.W. PV SUPPORT FRAME POST LOC'S 103' - 6" 9 S-202 96' - 0" B.O.W. 1'-5 1/2" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 1'-5 1/2" 6'-0" 98' - 8" B.O.W. 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 8'-6" Level 3 125' - 8" HSS6x6x1/2 HSS6x6x1/2 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 10'-0" 1'-0" 9'-0" 9'-0" 6" 3'-6" MIN. VARIES RAMP SLAB ~ EL. VARIES 175 North 27th Street, Suite 1312 Billings, MT 59101-2048 406.256.1141 P S PS APS FM LT SD PDS S T T H N T S T A T I T AI T G CO CO2 NO2 M SIZE A CFM TYPE F D C MECHANICAL LEGEND ABBREVIATIONS CONTROLS LEGEND PROJECT INFORMATION GENERAL NOTES (FOR ALL MECHANICAL DRAWINGS) REF CO CO ICE T NO 2 1.5" Mechanical, Electrical & Energy Consultants Greenwood Village, CO 80111-2518 7600 East Orchard Road, Suite 250-S 303.796.6000 www.mkkeng.com Cheyenne, WY 82001-4368 307.634.7647 500 West 18th Street, Suite 200 2 FLEXIBLE PIPE CONNECTOR (STAINLESS STEEL BRAIDED) EXISTING FIRE SPRINKLER EXISTING FIRE SPRINKLER TO BE REMOVED EXISTING FIRE SPRINKLER TO BE RELOCATED FLEXIBLE EQUIPMENT CONNECTOR (RUBBER DOUBLE BELLOWS) SHUT-OFF VALVE W/TAMPER SWITCH UP UP FD FD FD FD FD FD FD FD FD FD FD FD T T M M M T T T T T 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 FCU-1 ACCU-1 300 10"ø A 300 10"ø A 400 4-60 C 400 4-60 C 24/14 10/10 24x24 D 24x24 D CU-1 CU-2 CU-3 FC-3 FC-2 FC-1 300 10"ø A DN DN FD FD FD FD T 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 ACCU-2 FCU-2 106 107 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 NO SCALE NO SCALE NO SCALE POWER ELECTRICAL RL RS FAN COIL - DX/ELECTRIC HEAT - PRESSURE DEPENDENT OUTSIDE AIR CONTROL DRAWING AND SEQUENCE OF OPERATION SPACE TEMPERATURE MONITOR - IT ROOM CONTROL DRAWING AND SEQUENCE OF OPERATION ELECTRIC UNIT HEATER TERMINAL - UNIT CONTROLS CONTROL DRAWING AND SEQUENCE OF OPERATION AI- RAT AI- MAT BI- LTDA AI- SAT AI- SPT BI- RSD BO- FSS BI- FST BO- OAD AO- ECMOD STG1 BO- STG2 BO- CALR BI- AI- SPT SUPPLY AIR SPACE TEMPERATURE SENSOR AS SHOWN ON PLAN, TYP LOCATED IN IN I.T. ROOM FIELD VERIFY QUANTITIES SUPPLY AIR T T LT T T CT FS T CONTROL SYSTEM DATA POINT MATRIX NC OUTSIDE OCCUPANT OCCUPANT BREATHING TABLE 6-2 ZONE TOTAL SUPPLY SYSTEM OUTDOOR AREA DENSITY ZONE AIR AIR TO ZONE AT ZONE VENTILATION MINIMUM MINIMUM UNIT FLOOR ROOM ROOM NAME ZONE TYPE AREA AIRFLOW OUTDOOR PEOPLE OCCUPANT OUTDOOR DISTRIBUTION CONDITION VENTILATION EFFICIENCY PERCENTAGE OUTSIDE AIRFLOW NUMBER SQ FT RATE AIRFLOW RATE PER 1000 QUANTITY AIRFLOW RATE EFFECTIVENESS ANALYZED EFFICIENCY NOTE 2 AIRFLOW AT AT UNIT CFM/PER CFM/SQ FT SQ FT CFM (Ez) CFM - NOTE 1 (Evz) (Ev) UNIT NOTE 3 FC-1 1ST FLOOR 100 RETAIL Sales (except as below) 925 7.5 0.12 15 14 215 0.8 1400 0.96 0.96 - - FC-1 TOTALS 1400 - 0.96 16% 224 SPECIFIC NOTES: 1. TOTAL SUPPLY AIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. 2. AS DETERMINED USING THE ASHRAE 62.1-2010 "62 MZ Calc" SPREADSHEET. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. 3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. ASHRAE STANDARD 62.1-2010 / IMC 2012 VENTILATION RATE PROCEDURE CALCULATIONS OCCUPANT OCCUPANT BREATHING TABLE 6-2 ZONE TOTAL SUPPLY SYSTEM OUTDOOR AREA DENSITY ZONE AIR AIR TO ZONE AT ZONE VENTILATION MINIMUM MINIMUM UNIT FLOOR ROOM ROOM NAME ZONE TYPE AREA AIRFLOW OUTDOOR PEOPLE OCCUPANT OUTDOOR DISTRIBUTION CONDITION VENTILATION EFFICIENCY PERCENTAGE OUTSIDE AIRFLOW NUMBER SQ FT RATE AIRFLOW RATE PER 1000 QUANTITY AIRFLOW RATE EFFECTIVENESS ANALYZED EFFICIENCY NOTE 2 AIRFLOW AT AT UNIT CFM/PER CFM/SQ FT SQ FT CFM (Ez) CFM - NOTE 1 (Evz) (Ev) UNIT NOTE 3 FC-2 1ST FLOOR 101 RETAIL Sales (except as below) 875 7.5 0.12 15 13 203 0.8 1400 0.96 0.96 - - FC-2 TOTALS 1400 - 0.96 15% 211 SPECIFIC NOTES: 1. TOTAL SUPPLY AIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. 2. AS DETERMINED USING THE ASHRAE 62.1-2010 "62 MZ Calc" SPREADSHEET. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. 3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. ASHRAE STANDARD 62.1-2010 / IMC 2012 VENTILATION RATE PROCEDURE CALCULATIONS OCCUPANT OCCUPANT BREATHING TABLE 6-2 ZONE TOTAL SUPPLY SYSTEM OUTDOOR AREA DENSITY ZONE AIR AIR TO ZONE AT ZONE VENTILATION MINIMUM MINIMUM UNIT FLOOR ROOM ROOM NAME ZONE TYPE AREA AIRFLOW OUTDOOR PEOPLE OCCUPANT OUTDOOR DISTRIBUTION CONDITION VENTILATION EFFICIENCY PERCENTAGE OUTSIDE AIRFLOW NUMBER SQ FT RATE AIRFLOW RATE PER 1000 QUANTITY AIRFLOW RATE EFFECTIVENESS ANALYZED EFFICIENCY NOTE 2 AIRFLOW AT AT UNIT CFM/PER CFM/SQ FT SQ FT CFM (Ez) CFM - NOTE 1 (Evz) (Ev) UNIT NOTE 3 FC-3 1ST FLOOR 102 RETAIL Sales (except as below) 910 7.5 0.12 15 14 212 0.8 1400 0.96 0.96 - - FC-3 TOTALS 1400 - 0.96 16% 220 SPECIFIC NOTES: 1. TOTAL SUPPLY AIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. 2. AS DETERMINED USING THE ASHRAE 62.1-2010 "62 MZ Calc" SPREADSHEET. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. 3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. ASHRAE STANDARD 62.1-2010 / IMC 2012 VENTILATION RATE PROCEDURE CALCULATIONS EQUIP TAG TYPE FACE SIZE IN. MOUNTING TYPE DAMPER REQUIRED MATERIAL MANUFACTURER & MODEL NO. PLAN INFO SPECIFIC NOTES A LOUVER FACE CEILING DIFFUSER 24" x 24" TILE CLG YES STEEL KRUEGER SHR NECK / CFM 7 B LOUVER FACE CEILING DIFFUSER --- HARD CLG YES STEEL KRUEGER SHR NECK / CFM 1, 7 C LINEAR SLOT DIFFUSER SEE PLANS --- YES ALUMINUM KRUEGER 1975 #SLOTS-LENGTH / CFM 4, 5 D PERFORATED FACE CEILING RETURN GRILLE --- --- NO STEEL KRUEGER 6490/6690 NECK / CFM* 2, 3, 6 GENERAL NOTES: 1. SEE PLANS FOR NECK SIZE 2. ALL GRDs REQUIRING DAMPERS SHALL BE EQUIPPED WITH A REMOTE BALANCING DAMPER THAT IS ADJUSTABLE THROUGH THE GRD FACE OR ANOTHER APPROVED LOCATION UNLESS SUPPLIED FROM AN ACCESSIBLE TAKE-OFF WITH LOCKING DAMPER. 3. VERIFY GRD FINISH AND CLG/WALL/SILL/FLOOR MOUNTING TYPE WITH ARCHITECT FOR EACH APPLICATION PRIOR TO ORDERING. 4. PROVIDE 4-WAY THROW FOR DIFFUSERS UNLESS OTHERWISE SHOWN ON PLANS. 5. PROVIDE MANUFACTURERS ROUND TO RECTANGULAR ADAPTIVE COLLAR FOR DIFFUSERS AND GRILLES AS REQUIRED, MATCH DUCT SIZE AND TYPE 6. MATERIAL SHALL BE STEEL UNLESS OTHERWISE INDICATED OR SPECIFIED. MATERIAL SHALL BE SUITABLE FOR INSTALLED ENVIRONMENT. FOR WET LOCATIONS SUCH AS LOCKER ROOMS, RESTROOMS, SHOWER ROOMS, KITCHENS, POOL ROOMS, ETC....PROVIDE ALUMINUM. UP UP FD FD FD FD FD FD FD FD FD FD FD FD 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 4" F 1 1/2" DCW 1 1/2" DCW 1" DCW 4" SAN 4" SAN 4" SAN TD-1 ESP-1 (TYP. 12) 8" SAN 4" SAN WH-1 4" GW 4" GW 4" GW FD-1 SOI-1 4" SO 4" SO 4" SO 4" SO 4" SO 4" SO 4" SO 4" SO WH-1 WH-1 DSN-1 DSN-1 3" 4" 4" GW 4" GW AC-1 100 101 102 208 210 205 205 206 206 202 DN UP DN UP FD FD FD FD FD FD FD FD FD FD FD FD FD 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 AD-1 AD-1 (5260 SF) (5260 SF) FD-1 (TYP. 10) 6" ST 216 204 6" ST DN. 6" ST DN. 6" ST DN. 6" ST DN. 6" ST UP. 6" ST DN. 6" ST DN. RD-1 (760 SF) RD-1 (760 SF) ORD-1 ORD-1 RD-1 ORD-1 RD-1 ORD-1 (455 SF) (455 SF) 500 3" 3" 3" 3" 3" 3" 3" DN DN FD FD FD FD 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 AD-1 (6536 SF) AD-1 (4775 SF) AD-1 (5588 SF) AD-1 AD-1 AD-1 (5960 SF) (4775 SF) (6595 SF) 204 HT-1 WH-1 4" F DN. 4" F DN. 4" F DN. 4" F DN. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 NO SCALE NO SCALE FS PS PS FIRE ENTRY PIPING DETAIL SAND & OIL INTERCEPTOR AIR COMPRESSOR FOR DRY VALVES LOCATED IN WATER ENTRY EXTERIOR INTERIOR RE: PLBG DWGS FOR SIZES 4" MINIMUM RE: PLBG DWG SIZES INSTALL 6" CUP AND 4" DRAIN BELOW PURGE DRAIN OF BFP-1. ROUTE DRAIN TO DSN-1. SEE WATER ENTRY DETAIL 1-1/2" TO FUTURE RETAIL SPACES. CAPPED FOR FUTURE CONNECTION 1-1/2" DESIGN CRITERIA. PRESSURE DROPS BELOW TO INITIATE IF WATER WIRE TO FIRE ALARM PANEL DRY VALVE ZONE TO AREA: DRAIN, TYP. FLOOR BACKFLOW PREVENTER TO FIRE SYSTEMS. PROTECTION DRAIN VALVE, PIPE TO FLOOR FLOW SWITCH TO ALARMS. 1/2" PS AUTOMATIC BALL DRIP MIN. 4'-0" TO ALARMS. PRESSURE SWITCH LOCATION. PIPE TO OUTSIDE. TEST VALVE AT MOST REMOTE WALL SERVICE FLANGE 1'-6" MIN. GRADE FIRE CONNECTION 5'-0" MAX. FIRE DEPT. LIGHT AND HORN EXTERIOR RETAIL AREA. DRY VALVE ZONE TO AREA: ITEM TYPE SERVICE NO. GPM HEAD MOTOR SUMP MANUFACTURER & NOTES CONTROLS HP RPM V-PH STRTR DIA. DEPTH MODEL # ESP-1 SUBMERSIBLE ELEVATOR SHAFT 1.0 50.0 25.0 1 1750 115-1 -- 36.0 24.0 STANCOR - SE-100 O/M ELV 1 1 NOTES: 1. PROVIDE CAST IN PLACE SUMP IN BOTTOM OF ELEVATOR PIT AND CONTROL PANEL WITH DRY CONTACT TO BAS SYSTEM FOR PUMP FAILURE SUMP/SEWAGE PUMP SCHEDULE 1/26/2016 PLAN FIXTURE ICC/ANSI A117.1 MANUFACTURER SERIES TRIM SERIES SUPPLIES TRAP / DRAIN CW HW / WASTE VENT WATER NOTES / REMARKS CODE COMPLIANT # WASTE TEPID CONSUMPTION AD-1 AREA DRAIN --- J.R. SMITH 2450 --- --- --- --- INTEGRAL --- --- 4" --- --- W/GALVANIZED CAST IRON PARTS TRAFFIC RATED AND W/SEDIMENT BUCKET BFP-1 REDUCED PRESSURE --- FEBCO 860 / 860U --- --- INTEGRAL --- --- 2" --- --- --- --- W/MANUFACTURER'S MATCHING PRIN. BACKFLOW PREVENTOR 2" AIR GAP DRAIN DSN-1 DOWNSPOUT --- J.R. SMITH 1770 --- --- --- --- --- --- --- SEE --- --- MOUNT 24" ABOVE FIN. GRADE NOZZLE JOSAM 25010 PLANS FCO FLOOR CLEANOUT --- J.R. SMITH 4020/4040 --- --- --- --- --- --- --- SEE --- --- JOSAM 55000-1/-1SQ PLANS FD-1 FLOOR DRAIN --- J.R. SMITH 2450 --- --- --- --- INTEGRAL --- --- 4" --- --- W/GALVANIZED CAST IRON PARTS TRAFFIC RATED AND W/SEDIMENT BUCKET ORD-1 OVERFLOW --- J.R. SMITH 1070 --- --- --- --- --- --- --- SEE --- --- PROVIDE W/WATER DAM ROOF DRAIN JOSAM 21500-16 PLANS RD-1 ROOF DRAIN --- J.R. SMITH 1010 --- --- --- --- --- --- --- SEE --- --- JOSAM 21500 PLANS TD-1 TRENCH DRAIN --- MEA-JOSAM J1000 --- --- --- P-TRAP INTEGRAL --- --- 4" -- --- PROVIDE SEDIMENT (CHANNEL DRAINAGE) INTERCEPTOR WHERE NOTED WH-1 WALL HYDRANT --- WOODFORD B65 --- --- W/ISO. --- --- 3/4" --- --- --- --- 1, MOUNT 18" ABOVE FIN. GRADE FROST PROOF VALVE WM-1 WATER METER --- MUELLER SERIES IIS --- --- W/ISO. --- --- 1-1/2" --- --- --- --- W/ELECTRONIC READING SYSTEM DISPLACEMENT VALVE FOR CONTROL CONNECTION LEGEND: CH = CHILD HEIGHT, CM = CEILING MOUNTED, CP = CHROME PLATED, CT = COUNTERTOP, FM = FLOOR MOUNTED, FV = FLUSH VALVE, PA = PRESSURE ASSIST, SS = STAINLESS STEEL, TP = PROVIDE TRAP PRIMER (TP-1) ADJACENT TO FIXTURE, WM = WALL MOUNTED (PROVIDE WITH A FLOOR MOUNTED CONCEALED CARRIER), UCT = UNDER COUNTERTOP GENERAL NOTES: 1. WHERE FIXTURE/EQUIPMENT MODEL NUMBERS ARE GIVEN THESE ARE FOR REFERENCE ONLY. WRITTEN # WHERE NOTED THE PLUMBING FIXTURE, EQUIPMENT AND ASSOCIATED ACCESSORIES SPECIFICATION REQUIREMENTS AND SCHEDULE NOTES HOLD PRESIDENCE. THE MORE STRIGENT SHALL APPLY SHALL BE ICC/ANSI A117.1 (ADA) COMPLIANT. EXPOSED CW, HW AND W PIPING ALONG WITH 2. SEE ARCHITECTURAL DWGS FOR MOUNTING HEIGHTS ON ALL WALL MOUNTED FIXTURES/EQUIPMENT, MIXING VALVE SHALL INSULATED. PIPING WITHIN CASEWORK THAT OPENS FOR FIXTURE ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER ANY VALUES WITHIN THIS SCHEDULE. USE IS CONSIDERED EXPOSED. 3. THE MINIMUM WASTE/VENT PIPE SIZE FOR BURIED PIPE SHALL BE 2". 4. ALL ACCESIBLE FIXTURES SHALL COMPLY WITH ICC/ANSI A117.1 (ADA), REFERENCE ARCH DWGS FOR SPECIFIC LOCATIONS. SEE NOTE # 5. ALL FIXTURES AND EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. SPECIFIC NOTES: 1. EQUIPMENT AND/OR ISOLATION VALVE SHALL BE CONCEALED (WITHIN ADJACENT WALL OR WITHIN CASEWORK). WHERE LOCATED IN WALL/CEILING COORDINATE FINAL DEVICE AND ACCESS DOOR LOCATION WITH ARCHITECT. PLUMBING FIXTURE AND EQUIPMENT SCHEDULE ITEM TYPE CAP DISCH MOTOR DATA OP MANUFACTURER SERVES NOTES CON- SCFM PRESS HP RPM V-PH STRTR WGT & MODEL NO. TROLS PSI LBS AC-1 RECIP -- 125 1/8 115-1 -- QUINCY COMPRESSOR DRY PIPE SPRINKLER ZONES -- -- NOTES: AIR COMPRESSOR SCHEDULE EQUIP SERVICE HEATING CAPACTIY ELECTRICAL MANUFACTURER & NOTES CONTROLS I I S C M I GF I I G 3 V A M J D J J J L M M P P/T L F T F F F F D H F F F FAAP F FAGP FACP A TV CC M C B B V M M S S W P K G SPD T MCC N F M PB UP FD FD FD FD FD FD FD FD FD FD FD FD UP O1 O1 1 1 O1 J 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 A AE AE A AES AE AE A A AE A A AE A AE AE A AES AE A AES B B CE CE CE C CE STORAGE ROOM 5 DE DE D D D D D D D D SCE SCE SCE SCE DN UP DN UP FD FD FD FD FD FD FD FD FD FD FD FD FD 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 AD AE AE A AES AE AE A A AE A A AE A A A AES A AE B B AE AE CE CE CE L1-4 PART 2/3 L1-5 PART 2/3 L1-7 L1-8 L1-9 L1-9 L1-9 L1-9 L1-9 L1-9 L1-9 L1-9 L1-9 L1-9 L1-9 102 102 102 102 DN DN FD FD FD FD P O1 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 CE CE CE CE L1-4 PART 3/3 L1-5 PART 3/3 L1-10 103 103 103 103 104 104 104 104 L1-11 L1-11 L1-11 L1-11 100 SAE SAE SAE SAE D SCE SCE WP,GFI WP,GFI WP,GFI WP,GFI 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER UP FD FD FD FD FD FD FD FD FD FD FD FD UP J J J J J J F F F P F F P F P J J F P F P F P F F F F F F F F F F F F F F F F F F F F P F P F P F P F P F F F DN UP DN UP FD FD FD FD FD FD FD FD FD FD FD FD FD J J J F F P F J F F J J J J J J J J J 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 WP WP, GFI 201 200 200 203 (TYP.) WP WP 201 WP, GFI 211 211 G1-10 G1-10 G1-28 G1-25 G1-27 G1-26 L1-13,15 L1-17,19 211 211 L1-12,14 L1-21,23 215 G1-36 211 211 211 211 L1-24,26 L1-16,18 L1-25,27 L1-20,22 DN DN FD FD FD FD F J J J F F P F F J F F F 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 WP WP, GFI WP, GFI 200 201 200 EL-1 EL-1,LTG 203 (TYP.) WP WP WP WP WP WP WP 201 WP WP WP WP WP WP WP WP WP WP G1-12 G1-12 G1-40 G1-42 G1-39 NO SCALE UG UG FAULT CURRENT CALCULATIONS GENERAL NOTES: Maximum Available Fault Current (IAIC) I SCA = (I AIC x M) Where M = 1 / (1+f), and f = (1.732 x L x I AIC) / (C x n x E) (Note: Use "1/0" for 1/0AWG wire size, "2/0" for 2/0AWG, "3/0" for 3/0AWG, and "4/0" for 4/0AWG) Point Fault Location Length, feet Conductors size # conductors per phase Cu (1) Al (2) Conduit Magnetic (1) Nonmagn. (2) Voltage Phase "C" Value Previous fault value Fault value U Service Transformer Secondary Winding 1000kVA 52,190 1 "GMDP" 150 350 2 1 1 208 3 19703 52,190 19,662 2 PNL "G1" 4 "3/0" 1 1 1 208 3 12843 19,662 18,708 3 PNL "LVP" 4 6 1 1 1 208 3 2425 18,708 14,884 4 PNL "L1" 2 1 1 1 1 208 3 7292 19,662 18,817 5 ELEV 3 100 4 1 1 1 208 3 3806 19,662 3,709 6 PNL "T1" 128 1 1 1 1 208 3 7292 19,662 5,075 7 PNL "T2" 89 1 1 1 1 208 3 7292 19,662 6,558 8 PNL "T3" 147 1 1 1 1 208 3 7292 19,662 4,572 9 FC-1 120 4 1 1 1 208 3 3806 19,662 3,191 10 FC-2 90 4 1 1 1 208 3 3806 19,662 4,036 11 FC-3 130 4 1 1 1 208 3 3806 19,662 2,983 12 NO SCALE SMOKE DETECTOR LOCATED AT ELEVATOR LOBBY OF EACH FLOOR, NFPA 72-5.6.5. TO INITIATE ELEVATOR RECALL. SMOKE DETECTOR LOCATED AT TOP OF SHAFT IF REQUIRED FOR CONTROL OF ELEVATOR SHAFT DAMPER (COORDINATE WITH DIV. 15) OR IF HOISTWAY IS SPRINKLED. IT SHALL INITIATE ELEVATOR RECALL. (ASME 17.1- 211.3b REQUIRES SMOKE DETECTORS IN SPRINKLED HOISTWAYS.) COMBINATION 190° F RATE OF RISE/FIXED TEMP. HEAT DETECTOR LOCATED AT TOP OF SHAFT (ONLY IF SHAFT IS SPRINKLED) SHALL INITIATE ELEVATOR SHUT DOWN ASME A17.1 102.2(c)(3). NFPA 72-3-8.14.3 PROHIBITS PUTTING DETECTORS IN THE HOISTWAY (SHAFT OR PIT) UNLESS IT IS SPRINKLED. SWITCH FOR ELEVATOR CAB LIGHTING SHALL BE BE 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:32 PM E501 LUMINAIRE SCHEDULES & COMCHECK 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 INTERIOR LUMINAIRE SCHEDULE TYPE SOURCE 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:33 PM E502 ELECTRICAL SCHEDULES 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 Notes: Spare: 186 A Total Est. Demand: 14 A Total Conn.: 14 A NO SCALE ELEVATOR PIT PLAN ELEV. 1 LADDER SEPARATE BRANCH CIRCUIT REQUIRED FOR PIT LIGHTING AND RECEPTACLE. DON'T CONNECT LIGHT TO LOAD SIDE OF GFI RECEPTACLE. NEC 620.24. +50" GFI PROVIDE 4'-0" LED STRIP LIGHT, WET LOCATION LISTED, VERTICALLY MOUNTED IN EACH CORNER OF ELEVATOR SHAFT ON EACH LEVEL THAT THE SHAFT IS INTENDED TO BE ACCESSED. LITHONIA LIGHTING: #XWMLED. PIT RECEPTACLES MUST BE GFI NEC 620.85 PROVIDE SWITCH FOR PIT LIGHT(S) SWITCH FOR PIT LIGHT SHALL BE ACCESSIBLE FROM THE PIT ACCESS DOOR DOOR. ASME A17.1 2.2.5.3 NOTE: MACHINEROOMLESS ELEVATORS REQUIRE MAINTENANCE FROM THE TOP OF THE ELEVATOR CAR. LIGHTS AND A RECEPTACLE SHOULD BE PROVIDED AT THE FLOOR IN WHICH MAINTENANCE WILL BE PERFORMED (USUALLY THE TOP OF THE SHAFT) NOTE: FOR ALL ELEVATORS DESIGNATED AS FIRE SERVICE ACCESS ELEVATORS, PROVIDE ONE LIGHT (LITHONIA #XWMLED) PER FLOOR MOUNTED IN ALTERNATING CORNERS TO CREATE A SPIRAL PATTERN THE FULL HEIGHT OF THE SHAFT. THESE FIXTURES SHALL BE POWERED ON BY THE ELEVATOR CONTROLLER UPON ACTIVATION OF THE PHASE I RECALL. NO SCALE LIGHTING CONTROLS DETAIL PARKING DECK TIME CLOCK ON TO 100% OF FULL OUTPUT FOR ALL FIXTURES ON THIS LEVEL 30 MINUTES PRIOR TO SUNSET. STARTING AT 10:00 PM, DIM TO 20% OF FULL OUTPUT FOR ALL FIXTURES ON THIS LEVEL 20 MINUTES AFTER LAST DETECTION OF OCCUPANCY ON THIS LEVEL. RAISE TO 100% OF FULL OUTPUT FOR ALL FIXTURES ON THIS LEVEL UPON DETECTION OF OCCUPANCY DURING TIME CLOCK ON HOURS. TIME CLOCK OFF FOR ALL FIXTURES ON THIS LEVEL 30 MINUTES AFTER SUNRISE. AUTOMATIC OVERRIDE ON TO 100% OF FULL OUTPUT FOR ALL EMERGENCY FIXTURES ON THIS LEVEL UPON LOSS OF NORMAL POWER. LEVEL 1 EXTERIOR SCONCES TIME CLOCK ON TO 100% OF FULL OUTPUT FOR ALL BUILDING-MOUNTED FIXTURES 30 MINUTES PRIOR TO SUNSET. STARTING AT 10:00 PM, DIM TO 20% OF FULL OUTPUT FOR ALL BUILDING-MOUNTED FIXTURES 20 MINUTES AFTER LAST DETECTION OF OCCUPANCY ON THIS LEVEL. RAISE TO 100% OF FULL OUTPUT FOR ALL BUILDING-MOUNTED FIXTURES UPON DETECTION OF OCCUPANCY DURING TIME CLOCK ON HOURS. TIME CLOCK OFF FOR ALL BUILDING-MOUNTED FIXTURES 30 MINUTES AFTER SUNRISE. AUTOMATIC OVERRIDE ON TO 100% OF FULL OUTPUT FOR ALL BUILDING-MOUNTED FIXTURES UPON LOSS OF NORMAL POWER. LEVELS 1-2 AUTOMATIC ON TO 100% OF FULL OUTPUT FOR ALL FIXTURES ON THE ASSOCIATED LEVEL UPON DETECTION OF OCCUPANCY ON THE ASSOCIATED LEVEL. DIM TO 20% OF FULL OUTPUT FOR ALL FIXTURES ON THE ASSOCIATED LEVEL 20 MINUTES AFTER LAST DETECTION OF OCCUPANCY DURING NORMAL BUSINESS HOURS. DIM TO 20% OF FULL OUTPUT FOR ALL FIXTURES ON THE ASSOCIATED LEVEL 10 MINUTES AFTER LAST DETECTION OF OCCUPANCY AFTER NORMAL BUSINESS HOURS. AUTOMATIC OVERRIDE ON TO 100% OF FULL OUTPUT FOR ALL EMERGENCY FIXTURES ON THE ASSOCIATED LEVEL UPON LOSS OF NORMAL POWER. LEVELS 1-2 DAYLIGHT ZONES AUTOMATIC ON TO 100% OF FULL OUTPUT FOR ALL FIXTURES ON THE ASSOCIATED LEVEL UPON DETECTION OF OCCUPANCY ON THE ASSOCIATED LEVEL. DIM TO 20% OF FULL OUTPUT FOR ALL FIXTURES ON THE ASSOCIATED LEVEL 20 MINUTES AFTER LAST DETECTION OF OCCUPANCY DURING NORMAL BUSINESS HOURS. DIM TO 20% OF FULL OUTPUT FOR ALL FIXTURES ON THE ASSOCIATED LEVEL 10 MINUTES AFTER LAST DETECTION OF OCCUPANCY AFTER NORMAL BUSINESS HOURS. AUTOMATIC OVERRIDE ON TO 100% OF FULL OUTPUT FOR ALL EMERGENCY FIXTURES ON THE ASSOCIATED LEVEL UPON LOSS OF NORMAL POWER. ADDITIONAL DAYLIGHTING CONTROL: FIXTURES IN DAYLIGHT ZONES DIM TOGETHER AS GROUPED AND DESIGNATED ON PLANS. UP UP FD FD FD FD FD FD FD FD FD FD FD FD UP S1 S2 CB3 CB1 CB2 S8 S8 S8 S8 S8 S8 S8 S8 S13 (ALT) R7-1 S8 S8 S14 (ALT) S15 (ALT) S16 (ALT) S8 R7-8a R7-8 R7-8a S12 R7-8 S8 S12 R7-1 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S9 S9 S11 S10 R7-1 S8 S8 S12 S8 S12 S8 S8 S20 S17 S20/S21 S23 S20 S27 S26 S24 S20 S20/S22 S25 S23 S12 S10 FACE OF SIGN (SEE SIGN SCHEDULE) MARK (TYPICAL ALL LEVELS) SIGN KEY FIRST LEVEL DN UP DN UP S6 S7 S8 S8 S8 S8 S8 S8 S8 S8 S13 R7-1 S8 S8 S12 S8 S8 S8 S9 S9 S11 S10 S5 S29 S3 S5 S8 S12 S13 S12 R7-8 R7-8 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S8 S12 S8 S8 S12 S8 S12 S8 S12 S8 S12 S8 S12 S12 S8 S12 R7-1 S8 S12 S8 S12 R7-1 S8 R7-1 S8 S12 S8 S12 S8 S17 S20/S21 S20/S22 S23 S12 S4 S28 S23 S31 S30 S32 S11a S30 S32 S11a S31 S11a S31 S30 S32 4 3.7 3 2 1.6 1.3 1 A B DN DN S13 S12 S12 S13 R7-8 R7-8 S12 S12 S12 S12 S12 S12 S12 S12 S12 S8 S12 S12 S8 S8 S12 S12 S8 S8 S8 S17 S20/S21 S20/S22 S23 S12 S23 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S12 S11a S31 S12 S11a S31 S12 S12 S30 S32 S12 S30 S32 S12 S30 S32 S11a S31 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 16' - 7" 22' - 5" 40' - 0" 40' - 0" 40' - 0" 40' - 0" 25' - 10" 13' - 2" 4' - 2" 18' - 4" 36' - 1" 62' - 6" 19' - 1" 19' - 1" 16' - 3" ELEV PAY STATION EMERGENCY CALL BOX PAY STATION EMERGENCY CALL BOX 6" DIA. BOLLARD 2' - 6" 4' - 4" 16 SPACES AT 8'-9" = 154' - 8" 3' - 0" 65° 16'-6" 8'-10" =90° 5'-0"/8'-0" =90° 8'-0" =90° 8'-0" 2'-0" 8'-10" (8'-10" AT VAN) 5'-7" 4" WIDE WHITE PAINT STRIPE, TYPICAL INTERNATIONAL SYMBOL OF ACCESSIBILTY PAINTED WHITE, TYPICAL 90º 16'-6" (8'-0" AT VAN) 5'-0" 2'-10" 8'-0" 2'-0" 8'-0" 4" WIDE WHITE PAINT STRIPE, TYPICAL INTERNATIONAL SYMBOL OF ACCESSIBILTY PAINTED WHITE, TYPICAL 4" WIDE WHITE PAINT STRIPE AT 45°, TYPICAL 1'-0" 6'-1" 9'-8" 7'-8" = 90° 8'-9" 6'-1" 65° 16'-6" 16'-6" 1'-0" FACE OF WALL, WHERE APPLICABLE CURB, WHERE APPLICABLE CONTINUE STRIPING WHERE APPLICABLE WITH 4" WIDE CENTER STRIPE BETWEEN BAYS 4" WIDE WHITE PAINT STRIPE, TYPICAL END OF STRIPING STRING START OF STRIPING STRING PER DRAWINGS 10'-0" 9'-0" 16'-6" 16'-6" 1'-0" FACE OF WALL, WHERE APPLICABLE CURB, WHERE APPLICABLE CONTINUE STRIPING WHERE 8'-0" 8" 6" EQUAL 1'-9" EQUAL 3" CAP HEIGHT, COLOR BLACK BLACK ON YELLOW RETROREFLECTIVE BACKGROUND STICKER 2" CAP HEIGHT, COLOR BLACK BLACK PVC PIPE MOUNTING HEIGHT 8 FT 2 IN 8'-0" 8" 6" EQUAL 1'-9" EQUAL 3" CAP HEIGHT, COLOR BLACK BLACK ON YELLOW RETROREFLECTIVE BACKGROUND STICKER 2" CAP HEIGHT, COLOR BLACK BLACK PVC PIPE MOUNTING HEIGHT 7 FT 6 IN 8'-0" 8" EQUAL 6" 3" 3" 6" EQUAL DONOT ENTER DONOT ENTER 6" CAP HEIGHT, CENTERED, COLOR WHITE WHITE ON RED RETROREFLECTIVE STICKER, TYPICAL FEDERAL SIGN R5-1 SIMILAR MOUNTING HEIGHT BLACK PVC PIPE Exit Only 1'-0" MOUNTING 1'-6" HEIGHT NO PARKING ANY TIME 1'-0" 1'-6" 1 1/2" R, TYPICAL MOUNTING HEIGHT 2'-0" 6" E X T I N G U I S H E R RED WHITE LEGEND FIRE MOUNTING HEIGHT 5'-0" ABOVE FINISHED FLOOR EQUAL EQUAL 3 NOTES: 1. RAISED IMAGE TEXT WITH BRAILLE COPY TO CONFORM TO REQUIREMENTS OF AMERICAN'S WITH DISABILITIES ACT. 2. PROVIDE SIGN AT EACH ELEVATOR DOOR, EACH LEVEL. 2" HIGH HELVETICA MEDIUM MATTE FINISH RAISED IMAGE TEXT WITH GRADE-2 BRAILLE COPY BELOW (BY ELEVATOR CONTRACTOR). PROVIDE SIGN ON BOTH SIDES OF DOOR JAMB. 3" 5" MOUNTING HEIGHT EXIT SUPERSINE PROCESS DIE-RAISED LETTER .102" ALUMINUM SIGN (OR APPROVED EQUIVALENT) BLACK MATTE FINISH (FACE, EDGES AND BACK) 1" HIGH HELVETICA MEDIUM SILVER TEXT (1/32" MINIMUM RAISED IMAGE RELIEF HEIGHT) GRADE-2 BRAILLE COPY NOTES: 1. SIGN TO BE MOUNTED ON WALL OR COLUMN ADJACENT OPENING TO EXIT. (WHERE DOOR IS USED - MOUNT ON WALL ADJACENT LATCH SIDE.) 2. MOUNT WITH STAINLESS STEEL TAMPERPROOF SCREWS. 3. SIGN AND MOUNTING TO CONFORM TO REQUIREMENTS OF AMERICAN'S WITH DISABILITIES ACT. 1/2" RADIUS MOUNTING HEIGHT VARIES 6" MINIMUM 8'-0" 1'-0" 3'-0" 1'-0" VARIES 3'-0" MOUNTING HEIGHT (SEE SCHEDULE) TRAFFIC FLOW PIPE CENTERLINE REFLECTIVE LETTER DIE-CUT TEXT (SEE SCHEDULE) 1/4"Ø DRAIN HOLE BELOW EACH HANGER ASSEMBLY 1/4" GALVANIZED BENT PLATE HANGER, 3" WIDE @ 4'-0" MAXIMUM SPACING 1/4"Ø PLASTIC COATED STEEL CABLE WITH CRIMP STYLE CLAMPS - PROTECT CUT END OF CABLE FROM CORROSION 1/4"Ø SELF-TAPPING STAINLESS STEEL SCREWS (2) 2" x 2" x 1/4" x 1'-0" ANGLES. ALUMINUM ANGLES IN SAWCUT ALONG PIPE AXIS - ATTACH ANGLES TOGETHER USING (2) 1/4"Ø STAINLESS STEEL SCREWS 1/4"Ø THREADED STUD EXPANSION ANCHOR WITH STAINLESS STEEL WASHER AND LOCK NUT FOR HANGER ATTACHMENT P/C SPANDREL OR P/C TEE LEG 8"Ø BLACK PVC PIPE WITH FLUSH, SMOOTH END CAPS AT EACH END OF PIPE - MOUNT HORIZONTAL ABOVE TRAFFIC LANE REFLECTIVE LETTER DIE-CUT TEXT (SEE SCHEDULE) 1/4"Ø DRAIN HOLE BELOW EACH HANGER ASSEMBLY SEE SECTION BELOW CLEARANCE BAR ELEVATION 2" 3/4" 3/4" 2" (SEE SCHEDULE) MOUNTING HEIGHT TOP OF PANEL WHERE APPLICABLE FACE OF COLUMN, WALL, OR BEAM "HILTI" METAL HIT ANCHOR OR APPROVED EQUAL @ 3'-0" ON CENTER (MINIMUM (4) ANCHORS PER SIGN) SIGN FACE BOTTOM OF BEAM WHERE APPLICABLE NOTES: 1. DO NOT OVERDRIVE ANCHORS. OVERDRIVEN ANCHORS WILL DAMAGE SIGNS. 2. WHERE TOP OF PANEL OR BOTTOM OF BEAM CONDITION OCCURS; MAINTAIN A CONSTANT 2" DIMENSION FROM TOP OF PANEL OR BOTTOM OF BEAM TO SIGN AS SHOWN. 3. SEE DETAIL 3/PK620 FOR SIGNS MOUNTED AT TOP LEVEL AND IN CONDITIONS WHERE SIGN FACE IS EXPOSED TO DIRECT SUNLIGHT. 1/16" MAXIMUM 1" 7/16" .080 NOMINAL ALUMINUM SIGN THICKNESS NOTES: 1. DO NOT OVERDRIVE ANCHORS. OVERDRIVEN ANCHORS WILL DAMAGE BUSHINGS AND SIGNS. 2. USE THIS MOUNTING DETAIL ON BUMPER WALLS, COLUMNS, PANELS AND BEAMS WITH DETAIL 2/PK620 AT TOP LEVEL AND IN CONDITIONS WHERE SIGN FACE IS EXPOSED TO DIRECT SUNLIGHT. ELEVATION SECTION SLOTTED HOLE IN SIGN FACE AT EACH REQUIRED LOCATION 5/8" OUTSIDE DIAMETER STAINLESS STEEL WASHER SIGN FACE NYLON BUSHING HILTI METAL HIT ANCHOR OR APPROVED EQUAL 1" 1" 1" 1" 2" 2" 1" 3/4" 3/4" (SEE SCHEDULE) MOUNTING HEIGHT WELDED CONNECTION (ALL AROUND) OPTION: 3" ANGLE (MINIMUM) HORIZONTAL SLEEVE WELDED TO VERTICAL - PROVIDE (2) STAINLESS STEEL SELF-LOCKING CUP POINT SET SCREWS EACH HORIZONTAL, EACH END SIGN FACE FOR BACK TO BACK SIGNS A 1/8"Ø STAINLESS STEEL TAMPER PROOF SCREWS @ EACH VERTICAL AND MIDPOINT BETWEEN VERTICALS ALUMINUM ANGLE 3" x 3" x 1/4" WITH (2) 3/8"Ø x 2" EMBED. STAINLESS STEEL OR GALVANIZED HILTI KWIK-BOLT 3 OR APPROVED EQUAL 3/8"Ø STAINLESS STEEL BOLT AND LOCKNUT. SNUG LOCKNUT TO ALLOW SIGN TO SWING FREE (SEE NOTE 2) 1" SQUARE x 1/8" WALL ALUMINUM HORIZONTAL (MINIMUM (2) REQUIRED) 1" SQUARE x 1/8" WALL ALUMINUM VERTICAL TUBE HANGER SIGN FACE NOTES: 1. HANGER SPACING 3'-0" ON CENTER MAXIMUM - MINIMUM (2) HANGERS PER SIGN. 2. OPTIONAL HANGER CONNECTION - 3/8"Ø STAINLESS STEEL CLEVIS PIN WITH HAIRPIN COTTER. 3. MAXIMUM SIGN CANTILEVER 1'-0". 4. ALUMINUM TUBING SHALL BE SQUARE CORNER EXTRUDED 6063-T52 OR 6061-T6. ALUMINUM ANGLE SHALL BE EXTRUDED 6061-T6. STAINLESS STEEL HARDWARE SHALL BE 300 SERIES MATERIAL. 5. USE NEOPRENE OR VINYL WASHERS BETWEEN DISSIMILAR METALS SURFACES IN AREAS SUBJECT TO CORROSION. 6. SEE DETAIL 4/PK620 FOR MOUNTING LOCATION IN RELATIONSHIP TO P/C TEE LEGS. ELEVATION A MOUNTING HEIGHT (SEE SCHEDULE) 4" 1'-0" 6" 1/2"Ø STAINLESS STEEL KWIK BOLT OR APPROVED EQUAL SET SCREW GALVANIZED BENT PLATE 1 1/2" WIDE x 3/16" THICK TOP CAP PLATE SIGN FACE BOTTOM CAP PLATE MOUNTING BRACKETS WITH TAMPER RESISTANT SIGN BOLTS 2 3/8" OUTSIDE DIAMETER GALVANIZED PIPE CONCRETE OR CMU BUMPER WALL NOTES: 1. PIPE TO BE VERTICAL. 2. LOCATE REINFORCEMENT PRIOR TO INSTALLATION OF BENT PLATE BRACKETS. SECTION A-A A A MOUNTING HEIGHT (SEE SCHEDULE) SEE STRUCTURAL PLANS 1'-0" MAXIMUM NOTES: 1. CENTER SIGN MOUNTING BETWEEN P/C TEE LEGS WHERE SIGNS ARE BACK TO BACK. TRAFFIC FLOW P/C TEE LEG, TYPICAL FACE OF SIGN SEE DETAIL 5/PK620 FOR ATTACHMENT TO P/C TEE 3'-6" 1'-0" 1'-6" SQUARE 1 2 2 1 SLAB-ON-GRADE 6"∅ STANDARD GALV STEEL PIPE FILED WITH CONCRETE 9" x 9" x 1/2" GALV STEEL PLATE W/ (4) 3/4"Ø x 4 3/4" EMBEDMENT STAINLESS STEEL EXPANSION ANCHORS @ 6 1/2" OC 1/4" NEOPRENE PAD, SEALANT ALL AROUND 3/16" NOTE: PAINT ENTIRE PIPE GUARD ASSEMBLY TRAFFIC YELLOW. SLOPE CONCRETE AT TOP FOR DRAINAGE INTER CELL SPACING WITHIN A CELL = .10" ROUNDED DOT (ACCEPTIBLE) SQUARE DOT (IS NOT ACCEPTIBLE) RECOMMEND ROUNDED OR DOMED CALIFORNIA BRAILLE DOTS, EACH DISTINCT AND SEPERATE. DOTS WITH STRAIGHT SIDES AND FLAT TOPS ARE NOT READABLE FOR MANY BRAILLE USERS. BRAILLE CELL INTER CELL SPACING = .20" 5. BRAILLE: CONTRACTED CALIFORNIA GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10 INCH (2.54 mm) ON CENTERS IN EACH CELL WITH 2/10 INCH (5.08 mm) SPACE BETWEEN CELLS, MEASURED M THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF 1/40 INCH (0.635 mm) ABOVE THE BACKGROUND. (SEE 10.005B FOR TEMPLATES) 1. CHARACTER TYPE: CHARACTERS ON SIGNS SHALL BE RAISED 1/32" (0.794 mm) MINIMUM AND SHALL BE HALVETICA MEDIUM UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE (SEE NOTE 5 BELOW). 2. CHARACTER SIZE: RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8" (15.9 mm) AND A MAXIMUM OF 2 INCHES (51 mm) HIGH. 3. FINISH AND CONTRAST: CONTRAST BETWEEN CHARACTERS, SYMBOLS AND THEIR BACKGROUND MUST BE 70% MINIMUM AND HAVE A NON- GLARE FINISH. 1117B.5.2 4. PROPORTIONS: CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH TO HEIGHT RATION OF BETWEEN 1:5 AND 1:10 1117B.5.3 ALL LETTERS MEASURED MUST BE UPPERCASE. AFTER CHOOSING A TYPE TO TEST, BEGIN BY PRINTING THE LETTERS I, X, AND 0 AT 1 INCH HIGH. PLACE THE TEMPLATES 1:1 SQUARE OVER THE X OR 0, WHICHEVER IS NARROWER. IF THE CHARACTER IS NOT WIDER THAN 1 INCH, NOR NARROWER THAN THE 3:5 RECTANGLE, THE PROPORTIONS ARE CORRECT. USE THE 1:5 RECTANGLE TO DETERMINE IF THE STROKE OF THE I IS TOO BROAD, AND THE 1:10 RECTANGLE TO SEE IF IT IS TOO NARROW. IF THE TESTS ARE PASSED, THE TYPESTYLE IS COMPLIANT WITH PROPORTION CODE (SEE 10.005A FOR TEMPLATES). TEMPLATE FOR CHECKING CHARACTER AND STROKE WIDTH TO HEIGHT PROPORTIONS: BRAILLE CELL DOT 1:1 100% CHARACTER WIDTH 1:5 20% STROKE WIDTH 3:5 60% 1:10 10% (VERTICAL OR HORIZONTAL) EQ EQ 5'-0" 5'-0" 4" MIN/ 12" MAX 4" MIN/ 12" MAX 4" MIN/ 12" MAX 5'-0" 4" MIN/ 12" MAX ACCESSIBLE DOOR SIGNAGE NOTES: 1. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE 60 IN. ABOVE THE FINISH FLOOR TO THE CENTERLINE OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. FOR PAIRS OF DOORS WHERE DOOR SWING IS LIMITED TO 90 DEGREES, MOUNT SIGN 9" FROM EDGE OF DOOR. FOR PAIRS OF DOORS WHERE DOOR SWING EXCEEDS 90 DEGREES, MOUNT SIGN DOOR WIDTH PLUS 9" FROM EDGE OF DOOR. 2. SIGNS SHALL BE INSTALLED CENTERED ON THE DOOR. MOUNTING HEIGHT SHALL BE 60 IN. ABOVE THE FINISH FLOOR TO THE CENTERLINE OF THE SIGN. THE COLOR AND CONTRAST OF THE SIGN SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE DOOR. ACCESSIBLE DOOR SIGNAGE ACCESSIBLE DOOR SIGNAGE 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/10/2016 11:43:31 AM PK620 SIGN MOUNTING DETAILS WALNUT ST & CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1SIGN SCALE: 3/4" MOUNTING = 1'-0" DETAIL 2SIGN SCALE: 3/4" MOUNTING = 1'-0" DETAIL 3SIGN SCALE: 12" MOUNTING = 1'-0" DETAIL 5SIGN SCALE: 3/4" MOUNTING = 1'-0" DETAIL 6SIGN SCALE: 3/4" MOUNTING = 1'-0" DETAIL 4SIGN SCALE: 3/4" MOUNTING = 1'-0" DETAIL 7PIPE SCALE: 3/4" BOLARD = 1'-0" - SLAB ON GRADE 9BRAILLE SCALE: 1" = 1'-0" INFORMATION 8DOOR SCALE: 1/4" = SIGNAGE 1'-0" LOCATION 5" 9" MOUNTING HEIGHT ELEVATOR SW STAIR SUPERSINE PROCESS DIE-RAISED LETTER .102" ALUMINUM SIGN (OR APPROVED EQUIVALENT) BLACK MATTE FINISH (FACE, EDGES AND BACK) 1" HIGH HELVETICA MEDIUM SILVER TEXT (1/32" MINIMUM RAISED IMAGE RELIEF HEIGHT) GRADE-2 BRAILLE COPY NOTES: 1. SIGN TO BE MOUNTED ON WALL OR COLUMN ADJACENT OPENING TO EXIT. (WHERE DOOR IS USED - MOUNT ON WALL ADJACENT LATCH SIDE.) 2. MOUNT WITH STAINLESS STEEL TAMPERPROOF SCREWS. 3. SIGN AND MOUNTING TO CONFORM TO REQUIREMENTS OF AMERICAN'S WITH DISABILITIES ACT. 4. COORDINATE NAME OF STAIR TOWER WITH OWNER. 1/2" RADIUS 3" 9" MOUNTING HEIGHT NE STAIR SUPERSINE PROCESS DIE-RAISED LETTER .102" ALUMINUM SIGN (OR APPROVED EQUIVALENT) BLACK MATTE FINISH (FACE, EDGES AND BACK) 1" HIGH HELVETICA MEDIUM SILVER TEXT (1/32" MINIMUM RAISED IMAGE RELIEF HEIGHT) GRADE-2 BRAILLE COPY NOTES: 1. SIGN TO BE MOUNTED ON WALL OR COLUMN ADJACENT OPENING TO EXIT. (WHERE DOOR IS USED - MOUNT ON WALL ADJACENT LATCH SIDE.) 2. MOUNT WITH STAINLESS STEEL TAMPERPROOF SCREWS. 3. SIGN AND MOUNTING TO CONFORM TO REQUIREMENTS OF AMERICAN'S WITH DISABILITIES ACT. 4. COORDINATE NAME OF STAIR TOWER WITH OWNER. 1/2" RADIUS 1'-2" 1'-9" 2" 4" 2" 7" 3" 3" 1 1/2'' RADIUS 2" CAP HEIGHT CENTERED HORIZONTALLY 1" CAP HEIGHT, CENTERED HORIZONTALLY 5" CAP HEIGHT, CENTERED HORIZONTALLY. SIGN TO INDICATE LEVEL NUMBER 1" CAP HEIGHT, CENTERED HORIZONTALLY GRADE-2 BRAILLE, TYPICAL NOTES: 1. SIGN TO BE MOUNTED IN A POSITION THAT IS READILY VISIBLE WHEN THE DOORS ARE IN THE OPEN AND CLOSE POSITIONS. 2. SIGN AND MOUNTING TO CONFORM TO IBC. THE CITY OF FORT COLLINS FIRE DEPARTMENT, AND THE AMERICAN'S WITH DISABILITIES AC REQUIREMENTS. 3. TEXT FONT AND COLORS BY OWNER. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND, WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. 4. COORDINATE NAME OF STAIR TOWER AND LEVEL WITH OWNER. 5. ARROW TO POINT DOWN AT UPPER LEVELS AND LEFT OR RIGHT AT GROUND LEVEL. NE STAIR 3 GROUND LEVEL ROOF ACCESS 1 THRU 3 EXIT AT MOUNTING HEIGHT MOUNTING HEIGHT 5" 1'-0" EQ EQ EQ 5/8" MIN 5/8" MIN 5/8" MIN EQ 1/4" ELECTRICAL ROOM 3/8" RADIUS TYP NOTES: 1. THE SIGN MESSAGE TO BE COORDINATED WITH ROOM NAMES AS SHOWN ON THE PLANS. 2. WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF THE DOOR, CLEAR OF DOOR SWING. NOTES: TYPE 3 ROOM NUMBER INTERIOR 1. 1/4" ACRYLIC PLAQUE, EASED EDGES. 2. RAISED NUMBERS AND BRAILLE PRODUCED BY PHOTOPOLYMER PROCESS TO CONFORM WITH CALIFORNIA TITLE 24 3. ALL EXPOSED SURFACES PAINTED/SCREEN PRINTED TO MATCH COLOR BREAKS AS SHOWN. EXTERIOR 1. 1/4" ALUMINUM OR ZINC PLAQUE,EASED EDGES. 2. SURFACE ETCHED TO PRODUCE RAISED NUMBERS AND BRAILLE TO CONFORM WITH CALIFORNIA TITLE 24. 3. ALL EXPOSED SURFACES PAINTED/SCREEN PRINTED TO MATCH COLOR BREAKS AS SHOWN. - ADHESIVE-MOUNTED TO WALLS. - TYPEFACE HELVETICA MEDIUM SIDE VIEW SEE SIGN SCHEDULE FOR ROOM NAME 4'-4" 1'-0" 3" 6 1/2" 3" EQUAL 6 1/2" EQUAL MOUNTING HEIGHT SYMBOL COLOR WHITE, TYPICAL BACKGROUND COLOR BLACK 6" CAP HEIGHT, CENTERED VERTICALLY, COLOR WHITE Park 4'-4" 3" 6 1/2" 3" EQUAL 6 1/2" EQUAL 1'-0" SYMBOL COLOR WHITE, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, BACKGROUNDWHITE COLOR COLOR BLACK MOUNTING HEIGHT Park 5" 8" RED BLACK WHITE In Case Of Fire Use Exit Elevators Are Out Of Service LEGEND 5'-4" 1'-0" 3" 6 1/2" 3" EQUAL EQUAL 6 1/2" SYMBOL COLOR BLACK, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, COLOR BLACK BACKGROUND COLOR WHITE MOUNTING HEIGHT Pay Station EQUAL EQUAL 4'-4" 1'-0" EQ 6 1/2" 2" 6 1/2" 8" 2" 2" 2" 2" 5" 4 7/8" 1" EQ MOUNTING HEIGHT SYMBOL COLOR WHITE, TYPICAL 4" CAP HEIGHT, CENTERED VERTICALLY, COLOR WHITE BACKGROUND COLOR BLACK Elevator Stairs 4'-4" 1'-0" 3 1/2" 5" 3 1/2" 4 7/8" 4'-4" 2" EQUAL EQUAL EQUAL 6 1/2" 2" 6 1/2" EQUAL SYMBOL COLOR WHITE, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, COLOR WHITE BACKGROUND COLOR BLACK MOUNTING HEIGHT Stairs 4'-4" 1'-0" 5" 3 1/2" 3 1/2" 4 7/8" 4'-4" 2" EQUAL EQUAL 2" 6 1/2" EQUAL 6 1/2" EQUAL SYMBOL COLOR WHITE, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, BACKGROUNDWHITE COLOR COLOR BLACK MOUNTING HEIGHT Stairs 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/10/2016 11:43:31 AM PK611 SIGN DETAILS WALNUT ST & CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 3SIGN SCALE: 3" = DETAIL 1'-0" S18 4SIGN SCALE: 1/2" DETAIL = 1'-0" S19 5SIGN SCALE: 3" = DETAIL 1'-0" S20 6SIGN SCALE: 3" = DETAIL 1'-0" S21 7SIGN SCALE: 3" = DETAIL 1'-0" S22 8SIGN SCALE: 1 1/DETAIL 2" = 1'-0" S23 9SIGN SCALE: 3" = DETAIL 1'-0" S26 10SIGN SCALE: 1" = DETAIL 1'-0" S28 11SIGN SCALE: 1" = DETAIL 1'-0" S29 2SIGN SCALE: 1" = DETAIL 1'-0" S17 1SIGN SCALE: 1" = DETAIL 1'-0" S16 12SIGN SCALE: 1" = DETAIL 1'-0" S30 13SIGN SCALE: 1" = DETAIL 1'-0" S31 14SIGN SCALE: 1" = DETAIL 1'-0" S32 RESERVED PARKING 6" 1" RESERVED PARKING NOTES: 1. THE VAN ACCESSIBLE SIGN SHALL BE CENTERED UNDER THE ACCESSIBLE PARKING SIGN AS SHOWN. 2. SEE DETAIL 5/PK610 FOR MORE INFORMATION ON RESERVED PARKING SIGN. MOUNTING HEIGHT VAN ACCESSIBLE 8'-0" 1'-0" 6 1/2" 3" EQUAL EQUAL 6 1/2" 3" 6" MOUNTING HEIGHT SYMBOL COLOR WHITE, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, BACKGROUNDWHITE COLOR COLOR BLACK RED CIRCLE, BLACK ARROW ON WHITE RETROREFLECTIVE STICKER Public Parking 4'-4" 1'-0" 3" 6 1/2" EQUAL EQUAL 6 1/2" EQ 6 1/2" 3" EQ SYMBOL COLOR WHITE, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, COLOR WHITE BACKGROUND COLOR BLACK MOUNTING HEIGHT Exit 4'-4" 1'-0" 3" 6 1/2" 3" EQUAL EQUAL 6 1/2" 3" 6" SYMBOL COLOR WHITE, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, COLOR WHITE BACKGROUND COLOR BLACK MOUNTING HEIGHT RED CIRCLE, BLACK ARROW ON WHITE RETROREFLECTIVE STICKER Park 4'-4" 1'-0" 3" 6 1/2" 3" SYMBOL COLOR WHITE, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, COLOR WHITE BACKGROUND COLOR BLACK MOUNTING HEIGHT Out 4'-4" EQUAL 6" EQUAL 1'-0" 3" 6" 6" 3" 1" MOUNTING HEIGHT WHITE ON RED RETROREFLECTIVE STICKER, TYPICAL 4" CAP HEIGHT, CENTERED VERTICALLY, COLOR WHITE BACKGROUND COLOR BLACK Enter Do Not 4'-4" 3" 6 1/2" 3" EQUAL 6 1/2" EQUAL 1'-0" SYMBOL COLOR WHITE, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, BACKGROUNDWHITE COLOR COLOR BLACK MOUNTING HEIGHT Out 4'-4" 1'-0" 3" 6 1/2" 3" EQUAL EQUAL 6 1/2" 3" 6" SYMBOL COLOR WHITE, TYPICAL BACKGROUND COLOR BLACK MOUNTING HEIGHT RED CIRCLE, BLACK ARROW ON WHITE RETROREFLECTIVE STICKER 6" CAP HEIGHT, CENTERED VERTICALLY, COLOR WHITE Out LEVEL COLOR GROUND SECOND THIRD NUMBER LEVEL G 2 3 1'-6" 1'-6" 3" 2" 2" 8" 3" 2 DESIGNATION COLORS SCHEDULE FOR LEVEL TO BE DETERMINED BY OWNER/ARCHITECT TO BE DETERMINED BY OWNER/ARCHITECT TO BE DETERMINED BY OWNER/ARCHITECT LEVEL NUMBER, SEE SCHEDULE BACKGROUND COLOR, SEE SCHEDULE LETTER/SYMBOL COLOR WHITE FRUTIGER LT 55 ROMAN 1 1/2" RADIUS NOTES: 1. CENTER TEXT ON SIGN. 2. GENERAL CONTRACTOR TO VERIFY AND COORDINATE COLORS WITH OWNER PRIOR TO ORDERING SIGNS. 3. PRIMARY SIGN COLORS SHOULD BE CONSIDERED INSTEAD OF PASTELS. RED, YELLOW AND ORANGE ARE NOT RECOMMENDED. MOUNTING HEIGHT Remember 4'-4" 1'-0" 5" 3 1/2" 3 1/2" 4 7/8" 4'-4" 2" EQUAL EQUAL 2" 6 1/2" EQUAL 6 1/2" EQUAL SYMBOL COLOR WHITE, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, BACKGROUNDWHITE COLOR COLOR BLACK MOUNTING HEIGHT Stairs EQUAL EQUAL 4'-4" 1'-0" 2" 6 1/2" EQ 6 1/2" 8" 2" 2" 2" 4 7/8" 5" 2" 1" EQ MOUNTING HEIGHT SYMBOL COLOR WHITE, TYPICAL 4" CAP HEIGHT, CENTERED VERTICALLY, BACKGROUNDWHITE COLOR COLOR BLACK Elevator Stairs EQUAL EQUAL 4'-4" 1'-0" 2" 6 1/2" EQ 6 1/2" 8" 2" 2" 2" 4 7/8" 5" 2" 1" EQ MOUNTING HEIGHT SYMBOL COLOR WHITE, TYPICAL 4" CAP HEIGHT, CENTERED VERTICALLY, BACKGROUNDWHITE COLOR COLOR BLACK Elevator Stairs 1'-10" 2'-3" Remember 3/8" license plate number. Pay at pay station at stair tower immediately after parking. NOTES: 1. CENTER TEXT ON SIGN. BACKGROUND COLOR WHITE 2" CAP HEIGHT, CENTERED VERTICALLY, COLOR BLACK MOUNTING HEIGHT 1 1/2" RADIUS 1 1/8" RADIUS 3/8" BORDER, COLOR BLACK 3'-10" 1'-0" EQUAL EQUAL 3/8" 4" CAP HEIGHT, CENTERED VERTICALLY, COLOR BLACK BACKGROUND COLOR WHITE MOUNTING HEIGHT 3/8" BORDER, COLOR BLACK 1 1/8" RADIUS P a y H e r e 5'-4" 1'-0" 6 1/2" 3" EQUAL EQUAL 6 1/2" 3" 6 1/2" SYMBOL COLOR BLACK, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, COLOR BLACK BACKGROUND COLOR WHITE MOUNTING HEIGHT Pay Here 5'-4" 1'-0" 3" 6 1/2" 3" EQUAL 6 1/2" EQUAL SYMBOL COLOR BLACK, TYPICAL 6" CAP HEIGHT, CENTERED VERTICALLY, BACKGROUND COLOR COLOR BLACK WHITE MOUNTING HEIGHT Pay Station REMARKS CB1 MARK W L 8'-0" SIZE TEXT/MESSAGE 8 FT 2 IN TYPE PVC SIGN SIGN SCHEDULE MOUNTING DETAIL HEIGHT SIGN DETAIL 1/PK620 8'-2" Pay Here 7 FT 6 IN PVC Exit Only Pay Station CB2 CB3 R7-1 R7-8 R7-8a S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 S15 S16 S17 8'-0" 8'-0" 1'-6" 1'-0" No Parking Any Time 1'-6" 1'-0" 2'-1" 1'-0" ........ VAN ........ Exit Park Public Parking Out Do Not Enter Out Out Level Designator Remember Stairs Stairs/Elevator Stairs/Elevator Remember License Plate Number ... Pay Here Pay Station In Case Of Fire... PVC V R R V V V V V V R PP PP PP PP PP PP PP VR PP 8'-0" 1'-6" 1'-6" 4'-4" 1'-10" 1/PK610 PP 2/PK610 3/PK610 4/PK610 5/PK610 6/PK610 7/PK610 8/PK610 9/PK610 10/PK610 11/PK610 12/PK610 13/PK610 14/PK610 15/PK610 16/PK610 17/PK610 18/PK610 19/PK610 20/PK610 21/PK610 22/PK610 1/PK611 1/PK620 7'-6" 1/PK620 8'-2" 2/PK620 5'-0" 5'-0" 5'-0" 4/PK620 2/PK620 5'-0" 2/PK620 2/PK620 2/PK620 6'-0" 5/PK620 8'-4" 7'-8" 5/PK620 8'-4" 7'-8" 5/PK620 8'-4" 7'-8" 4/PK620 8'-4" 7'-8" 4/PK620 8'-4" 7'-8" 8'-4" 7'-8" 5/PK620 8'-4" 5/PK620 8'-4" TWO COMPONENT SIGN MOUNT AT 8'-4" AT GROUND LEVEL, AND AT 7'-8" AT OTHER LEVELS MOUNT AT 8'-4" AT GROUND LEVEL, AND AT 7'-8" AT OTHER LEVELS MOUNT AT 8'-4" AT GROUND LEVEL, AND AT 7'-8" AT OTHER LEVELS MOUNT AT 8'-4" AT GROUND LEVEL, AND AT 7'-8" AT OTHER LEVELS MOUNT AT 8'-4" AT GROUND LEVEL, AND AT 7'-8" AT OTHER LEVELS MOUNT AT 8'-4" AT GROUND LEVEL, AND AT 7'-8" AT OTHER LEVELS MOUNT PER ELEVATOR MANUFACTURER 8'-4" 4/PK620 8'-4" 4/PK620 7'-8" 4/PK620 7'-8" 5/PK620 4/PK620 S18 Fire Extinguisher S19 Elevator Designation S20 Exit (Braille) S21 SW Stair/Elevator (Braille) S22 NE Stair (Braille) S23 Stair/Level Designation S24 Storage Room (Braille) S25 Mechanical Room (Braille) S26 Electrical Room (Braille) S27 Server Room (Braille) S28 Park S29 Park SIGNAGE GENERAL NOTES: 1. SIGN PANEL BACKGROUND AND LETTER COLORS TO BE PER MUTCD STANDARDS.CONTRACTOR TO VERIFY WITH OWNER/ARCHITECT PRIOR TO FABRICATION. 2. UPPER AND LOWER CASE SHALL BE USED ON ALL DIRECTIONAL TRAFFIC AND PEDESTRIAN SIGNS, UNLESS NOTED. 3. SIGN CONTRACTOR SHALL REVIEW SIGN LOCATIONS PRIOR TO INSTALLATION WITH ARCHITECT TO COORDINATE WITH LIGHTING SYSTEM. SIGN AND LIGHT LOCATIONS PER SPECIFICATIONS. 4. SIGNS SHALL BE MOUNTED LEVEL AND PLUMB, UNLESS NOTED. 5. WHERE TWO (2) SIGNS ARE MOUNTED BACK TO BACK, SMALLEST L DIMENSION SHALL INCREASE TO MATCH LARGEST L DIMENSION. 6. MAXIMUM BOLT INSERT EMBEDMENT LENGTH 1 1/4", UNLESS NOTED. 7. DO NOT SCALE DRAWINGS. 8. BACK AND EDGES OF ALL ALUMINUM SIGNS MOUNTED DIRECTLY TO STRUCTURE SHALL BE PAINTED (SIGHT BACKGROUND COLOR) TO PREVENT CATHODIC REACTIONS. 9. REFLECTIVE GRAPHICS AND COPY COLORS ARE 3M. ALL NON-REFLECTIVE COLORS AND PANTONE. 10. ALL FONTS TO BE ARIAL OR APPROVED EQUIVALENT SAN SERIF FONT, UNLESS NOTED OTHERWISE. SIGN TYPES LEGEND MARK TYPE V - REFLECTIVE VEHICULAR DIRECTIONAL AND INFORMATION SIGNS R - RETROREFLECTIVE REGULATORY SIGNS PVC - PVC PIPE CLEARANCE SIGNS VR - VANDAL-RESISTANT SIGNS A - BRAILLED ADA COMPLIANT IDENTIFICATION SIGNS PP - PEDESTRIAN PANEL 8"Ø 8"Ø 8"Ø 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 4'-4" 4'-4" 4'-4" 4'-4" 4'-4" 4'-4" 1'-0" 1'-0" 1'-0" 2'-3" 4'-4" 4'-4" 3'-10" 1'-0" 1'-0" 5'-4" 1'-0" 5'-4" 1'-0" 5'-4" 8" 5" 2'-0" 6" 3" 5" 5" 9" 3" 9" 1'-9" 1'-2" 5" 1'-0" 5" 1'-0" 5" 1'-0" 5" 1'-0" 1'-0" 4'-4" 1'-0" 4'-4" PP PP A A A A A A A A V V 2/PK611 3/PK611 4/PK611 5/PK611 6/PK611 7/PK611 8/PK611 8/PK611 8/PK611 8/PK611 9/PK611 5/PK620 8'-4" 10/PK611 5/PK620 8'-4" 5'-0" 5'-0" 5'-0" 2/PK620 5'-0" 2/PK620 2/PK620 2/PK620 2/PK620 2/PK620 2/PK620 2/PK620 2/PK620 2/PK620 - - 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" - - SEE DETAIL 8/PK620 FOR SIGN MOUNTING LOCATION SEE DETAIL 8/PK620 FOR SIGN MOUNTING LOCATION SEE DETAIL 8/PK620 FOR SIGN MOUNTING LOCATION SEE DETAIL 8/PK620 FOR SIGN MOUNTING LOCATION AT LEVEL 1 ATTACH TO UNISTRUT SUPPORTED BETWEEN TWO LIGHT WALLS 2/PK620 6/PK620 MOUNT ABOVE FIRE EXTINGUISHER CABINET. PLAN LOCATION APPROXIMATE S30 1'-0" 4'-4" S11a Stairs/Elevator PP FOR MOUNTING HEIGHT AT LEVEL 3, SEE DETAIL 1'-0" 4'-4" 2/PK620 5'-0" 2/PK620 - 5'-0" ATTACH TO UNISTRUT SUPPORTED BETWEEN TWO LIGHT WALLS OR SEE DETAILS 2/PK620 FOR MOUNTING HEIGHT AT LEVEL 3 Stairs/Elevator PP 11/PK610 1'-0" 4'-4" 2/PK620 5'-0" Stairs 1'-0" 4'-4" PP 1'-0" 4'-4" PP 2/PK620 5'-0" 2/PK620 5'-0" AT LEVEL 3 ATTACH TO UNISTRUT SUPPORTED BETWEEN TWO LIGHT WALLS AT LEVEL 3 ATTACH TO UNISTRUT SUPPORTED BETWEEN TWO LIGHT WALLS AT LEVEL 3 ATTACH TO UNISTRUT SUPPORTED BETWEEN TWO LIGHT WALLS S31 S32 12/PK610 Stairs 13/PK610 14/PK610 EQUAL EQUAL 4'-4" 1'-0" 2" 6 1/2" EQ 6 1/2" 8" 2" 2" 2" 4 7/8" 5" 2" 1" EQ MOUNTING HEIGHT SYMBOL COLOR WHITE, TYPICAL 4" CAP HEIGHT, CENTERED VERTICALLY, BACKGROUNDWHITE COLOR COLOR BLACK Elevator Stairs 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/10/2016 11:43:31 AM PK610 SIGN SCHEDULE AND DETAILS WALNUT ST & CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1SIGN SCALE: 1" = DETAIL 1'-0" CB1 2SIGN SCALE: 1" = DETAIL 1'-0" CB2 3SIGN SCALE: 1" = DETAIL 1'-0" CB3 4FEDERAL SCALE: 1" = 1'-0" SIGN R7-1 5FEDERAL SCALE: 1" = 1'-0" SIGN R7-8 6FEDERAL SCALE: 1" = 1'-0" SIGN R7-8a 7SIGN SCALE: 1" = DETAIL 1'-0" S1 8SIGN SCALE: 1" = DETAIL 1'-0" S2 9SIGN SCALE: 1" = DETAIL 1'-0" S3 10SIGN SCALE: 1" = DETAIL 1'-0" S4 11SIGN SCALE: 1" = DETAIL 1'-0" S5 12SIGN SCALE: 1" = DETAIL 1'-0" S6 13SIGN SCALE: 1" = DETAIL 1'-0" S7 14SIGN SCALE: 1" = DETAIL 1'-0" S8 15SIGN SCALE: 1" = DETAIL 1'-0" S9 16SIGN SCALE: 1" = DETAIL 1'-0" S10 17SIGN SCALE: 1" = DETAIL 1'-0" S11 19SIGN SCALE: 1" = DETAIL 1'-0" S12 20SIGN SCALE: 1" = DETAIL 1'-0" S13 21SIGN SCALE: 1" = DETAIL 1'-0" S14 22SIGN SCALE: 1" = DETAIL 1'-0" S15 18SIGN SCALE: 1" = DETAIL 1'-0" S11a APPLICABLE WITH 4" WIDE CENTER STRIPE BETWEEN BAYS 4" WIDE WHITE PAINT STRIPE, TYPICAL 1'-0" 2'-0" TYP. 45° VARIES SEE PLANS SEE PLANS 4" WIDE WHITE PAINT STRIPE, TYPICAL FACE OF WALL WHERE OCCURS 4'-0" 5'-4" 1'-10" 1'-8" 2'-0" 1'-0" 1'-3" 8" 2'-0" 8" 8" 8" 6'-0" 2'-9" 3'-3" 4" 2'-0" 8" 8" 8" 8'-0" 4'-9" 3'-3" 4" 1'-10" 1'-8" 8" 1'-0" 2'-0" 1'-3" 4'-0" 5'-4" NOTE: PAINT ARROWS SOLID WHITE, UNLESS NOTED OTHERWISE. 3'-6" MINIMUM 6" TYPICAL WHITE PAINT TYPICAL 9'-3" 4'-0" 10'-0" 4'-0" 1'-6" 2'-3" 17'-0" A B CR/I AG PROTECTIVE BOLLARD, TYPICAL SEE 8/PK601 C8 C5 C7 C9 C1 3/4" 6" 6" 4'-0" 1 1/4" TYP NOTES: 1. PAINT ENTIRE PIPE BOLLARD ASSEMBLY TRAFFIC YELLOW. 2. PARCS VENDOR AND GENERAL CONTRACTOR TO COORDINATE FINAL LOCATION OF PIPE BOLLARD WITH EQUIPMENT ACCESS REQUIREMENTS. 1/4 3/16 PAVEMENT RAKE SLAB SURFACE FOR BOND ISLAND CONSTRUCTION PER STRUCTURAL TOP OF CURB OR ISLAND COVE SEALANT ALL AROUND PLATE 6" x 10" x 1/2" GALV PLATE W/ (4) 3/4" DIA STAINLESS STEEL EXPANSION ANCHORS W/ 4 3/4" EMBEDMENT 1/8" NEOPRENE PAD 4" DIA GALV SCHEDULE 40 PIPE SET PLUMB W/ 5" DIA x 1/4" CAP PLATE PAINT VERT FACE AND 6" OF HORIZ FACE TRAFFIC YELLOW TYPICAL 6'-0" 2'-6" 45° NOTES: A. VERIFY SIZE OF LOOP, SIZE OF WIRE AND NUMBER OF TURNS AND NUMBER OF TWISTS PER FOOT IN LOOP LEADS WITH DETECTOR SUPPLIER BEFORE INSTALLATION. B. LOOP LEAD RUNS SHALL HAVE (4) TWISTS PER FOOT AND ARE LIMITED TO 100 FEET. C. LOOP AND LOOP LEADS SHALL BE LOCATED AT LEAST 18" FROM ANY ELECTRICAL POWER SERVICE OR RUNS, AND STEEL REINFORCING IF POSSIBLE. D. LOOP LEADS SHALL BE IN SEPARATE RIGID STEEL CONDUIT BETWEEN LOOP AND DETECTOR. IT MUST NOT SHARE CONDUIT WITH OTHER WIRING OR LEADS FROM OTHER LOOPS. E. LOOP AND LOOP LEAD WIRE SHALL BE 16-GAUGE XLPE CONDUCTOR STRANDED WIRE. ALL WIRE TO BE CONTINUOUS WITHOUT SPLICES. F. COORDINATE INSTALLATION WITH GENERAL CONTRACTOR. ℄ ℄ SAWCUT PAVEMENT 1/4" WIDE BY 1" DEEP. INSTALL 4 TURNS OF 16-GAUGE XLPE SINGLE CONDUCTOR WIRE. FILL SLOT WITH 3M DETECTOR LOOP SEALANT OR AN APPROVED EQUIVALENT. 16-GAUGE XLPE TWISTED CONDUCTOR WIRES TO LOOP DETECTOR UNIT IN 3.4" RIGID STEEL CONDUIT. AG 6'-0" 2'-6" CR\I GENERAL NOTES: 1. DRAWINGS ARE SCHEMATIC DIAGRAMS. PARCS CONTRACTOR TO COORDINATE FINAL CONDUIT QUANTITIES, SIZES, LOCATION OF CONDUIT STUB UPS, PROTECTIVE BOLLARDS, AND EQUIPMENT MOUNTING LOCATIONS. ELECTRICAL NOTES: 1. ALL EXPOSED CONDUIT TO BE RIGID HOT DIPPED GALVANIZED. 2. SEE EQUIPMENT LEGEND FOR POWER REQUIREMENTS. 3. COORDINATE WITH CIVIL AND ELECTRICAL DRAWINGS FOR POWER SUPPLY AND DATA LINE INTERFACES. 4. POWER AND COMMUNICATIONS SHALL BE ROUTED IN SEPARATE CONDUITS. VOLTAGE DROP SHALL BE LESS THAN 3%. CONDUITS AND CONDUCTORS SHALL BE SIZED PER THE NATIONAL ELECTRICAL CODE REQUIREMENTS. CONSULT ELECTRICAL ENGINEER FOR DETAILS. ISLAND PROTECTIVE BOLLARD CARD READER/INTERCOM POWER FROM GATE/BOOTH AUTOMATIC GATE 1-30A, 120V, 2400W CIRCUIT TYPICAL LOOP EQUIPMENT LEGEND DEFINITION CONDUIT LEGEND DESIGNATION SIZE DEFINITION C1 C5 C7 C8 C9 1 1/2" 1 1/2" 1" 3/4" 1" PARCS DATA RIGID STEEL LOOP LEAD POWER FEEDER, ONE 120V CIRCUIT FROM POWER SOURCE VOICE COMMUNICATION TO MAIN COMMUNICATION INTERFACE PARCS DATA FROM FACILITY MANAGEMENT SYSTEM EQUIPMENT 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/10/2016 11:43:30 AM PK601 STRIPING AND PARCS DETAILS WALNUT ST & CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 165° SCALE: ACCESSIBLE 1/8" = 1'-0" STRIPING DETAIL 290° SCALE: ACCESSIBLE 1/8" = 1'-0" STRIPING DETAIL 365° SCALE: STRIPING 1/8" = 1'-0" DETAIL 490° SCALE: STRIPING 1/8" = 1'-0" DETAIL 5STRIPING SCALE: 1/4" = 1'-0" DETAIL-NO PARKING AREA 7TYPICAL SCALE: 1/2" = 1'-0" ARROW DETAILS 6CROSSWALK SCALE: 1/8" = 1'-0" MARKING 9ENTRY/SCALE: 1/4" = 1'-EXIT 0" WITH CARD READER 8PIPE SCALE: 1" BOLLARD = 1'-0" DETAIL 10DETECTOR SCALE: 3/4" = 1'-0" LOOP DETAIL 3' - 0" OPEN TO BELOW RAMP DOWN 6.6 % DN 3' - 11 1/2" 18 SPACES AT 8'-9" = 174' - 0" 2' - 0" 9' - 0" 6' - 0" 8' - 0" 18 SPACES AT 8'-9" = 173' - 2 1/2" 5' - 6" 6' - 1" 8' - 10" 5' - 6" 8' - 10" 9 SPACES AT 8'-9" = 87' - 0" 10" 2 SPACES AT 9'-0" = 18' - 0" 1' - 0" 13' - 2" 2' - 0" 10 SPACES AT 8'-9" = 96' - 8" 5' - 11" 2' - 6" 3' - 6" 16 SPACES AT 8'-9" = 154' - 8" 3' - 10" 3' - 0" 9 SPACES AT 9'-0" = 81' - 0" 2' - 0" 9 SPACES AT 9'-0" = 81' - 0" 2' - 0" 7' - 6" 5 SPACES AT 8'-9" = 48' - 4" 4' - 8" R 6' - 0" R 5' - 0" R 3' - 0" R 6' - 0" R 6' - 0" R 5' - 0" S19 FIRST LEVEL ISOMETRIC EXPRESS RAMP EL. 0'-0" FIRST LEVEL EL. 4'-6" SECOND LEVEL EL. 15'-0" THIRD LEVEL EL. 25'-8" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/10/2016 11:43:29 AM PK103 FLOOR PLAN LEVEL 3 WALNUT ST & CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1THIRD SCALE: 3/32" LEVEL = 1'-0" FLOOR PLAN C D E F G 5 A.3 F.6 16' - 7" 22' - 5" 40' - 0" 40' - 0" 40' - 0" 40' - 0" 25' - 10" 13' - 2" 4' - 2" 18' - 4" 36' - 1" 62' - 6" 19' - 1" 19' - 1" 16' - 3" ELEV PAY STATION EMERGENCY CALL BOX PAY STATION EMERGENCY CALL BOX 6" DIA. BOLLARD 28' - 9 3/8" RAMP DOWN 6.6 % DN EXPRESS RAMP DOWN 13.9 % DN RAMP UP 6.67 % 4 SPACES AT 9'-0" = 36' - 0" 4' - 4 1/2" 2' - 6" 4' - 2" 9' - 0" 2' - 0" 10 SPACES AT 8'-9" = 96' - 8" 5' - 11" 2' - 6" 1' - 9" 16 SPACES AT 8'-9" = 154' - 8" 6' - 6" 2' - 6" 4 SPACES AT 9'-0" = 36' - 0" 4' - 4 1/2" 2' - 6" 2' - 6" 6' - 6" 16 SPACES AT 8'-9" = 154' - 8" 1' - 9" 2' - 6" 3' - 11 1/2" 18 SPACES AT 8'-9" = 174' - 0" 2' - 0" 9' - 0" 6' - 0" 4' - 0" 9 SPACES AT 9'-0" = 81' - 0" 4' - 0" 9 SPACES AT 9'-0' = 81' - 0" 5' - 6" 18 SPACES AT 8'-9" = 174' - 0" 7' - 3" 6' - 1" 8' - 10" 5' - 6" 8' - 10" 9 SPACES AT 9'-0" = 87' - 0" 10" 2 SPACES AT 9'-0" = 18' - 0" 1' - 0" R 8' - 0" R 3' - 0" R 5' - 0" R 5' - 0" R 8' - 0" R 3' - 0" R 3' - 0" R 3' - 0" S19 S30 S11a FIRST LEVEL ISOMETRIC EXPRESS RAMP EL. 0'-0" FIRST LEVEL EL. 4'-6" SECOND LEVEL EL. 15'-0" THIRD LEVEL EL. 25'-8" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/10/2016 11:43:28 AM PK102 FLOOR PLAN LEVEL 2 WALNUT ST & CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1SECOND SCALE: 3/32" = 1'-0" LEVEL FLOOR PLAN ISOMETRIC EXPRESS RAMP EL. 0'-0" FIRST LEVEL EL. 4'-6" SECOND LEVEL EL. 15'-0" THIRD LEVEL EL. 25'-8" 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 STORAGE ROOM MECH. 16' - 7" 22' - 5" 40' - 0" 40' - 0" 40' - 0" 40' - 0" 25' - 10" 13' - 2" 4' - 2" 18' - 4" 36' - 1" 62' - 6" 19' - 1" 19' - 1" 16' - 3" 16' - 7" 22' - 5" 40' - 0" 40' - 0" 40' - 0" 40' - 0" 25' - 10" 13' - 2" POTENTIAL RETAIL/OFFICE FLEX SPACE RAMP DOWN 5" RAMP ON GRADE W/ FIBROUS REINFORCING RAMP UP 6.67 % EXPRESS RAMP UP 13.9 % UP PUBLIC PARKING HOTEL VALET PARKING HOTEL VALET PARKING RETAIL/OFFICE FLEX SPACE JEFFERSON STREET CHESTNUT STREET ELEV FIREHOUSE ALLEY 1.9% 1.9% 5.7% DN FINISH FLOOR FINISH FLOOR CARD READER AND GATE SEE DETAIL 9/PK601 CARD READER AND GATE SEE DETAIL 9/PK601 PAY STATION (ALTERNATE) EMERGENCY CALL BOX (ALTERNATE) PAY STATION (ALTERNATE) EMERGENCY CALL BOX (ALTERNATE) FINISH FLOOR EL = 103' - 3 23/32" FINISH FLOOR STORAGE ROOM 8" TRENCH DRAIN - WIDTH OF RAMP SERVER ROOM ELEC. ROOM RAMP UP 1 % EMERGENCY CALL BOX (ALTERNATE) MECH. 6" DIA. BOLLARD 1.5% 1.2% 1.7% 1.5% EXTENTS OF FUTURE RETAIL/OFFICE EL = 104' - 1 23/32" SLOPE LANDING AWAY FROM DOORS FOR WATER DRAINAGE EL = 103' - 3 1/2" 4 SPACES AT 9'-0" = 38' - 8" 1' - 0" 9' - 0" 7' - 3" 4' - 0" 6' - 2" 16 SPACES AT 8'-9" = 154' - 8" 2' - 1" 2' - 3" 6 SPACES AT 9'-0" = 54' - 0" 3' - 11" 2' - 3" 2' - 0" 11' - 0" 5 SPACES AT 9'-0" = 45' - 0" 3' - 11" 2' - 3" 3 SPACES AT 9'-0" = 27' - 0" 1' - 0" 9' - 8" 16' - 11" 24' - 0" 36' - 2" 2 SPACES AT 9'-0"= 18' - 0" 2' - 0" 1' - 6" 2 SPACES AT 9'-0" = 18' - 0" 3' - 8" 3 SPACES AT 8'-9"= 29' - 0" 11' - 0" 3 SPACES AT 8'-9" = 29' - 0" 11' - 0" 3 SPACES AT 8'-9" = 29' - 0" 13' - 0" 4 SPACES AT 8'-9" = 38' - 8" 11' - 1 1/2" 9' - 0" 11 SPACES AT 8'-9" = 106' - 4" 2' - 5" 4' - 0" 1' - 8" 8' - 0" 8' - 0" 8' - 0" 2 SPACES AT 9'-0" = 17' - 0" 4' - 0" 1' - 8" 8' - 0" 8' - 0" 8' - 0" 2 SPACES AT 9'-0" = 17' - 0" 4' - 0" 1' - 6" 16 SPACES AT 8'-9" = 154' - 8" 6' - 9" 2' - 3" 3' - 6" R 8' - 0" R 4' - 0" R 5' - 0" R 3' - 0" R 5 ' - 0" R 5' - 0" R 8' - 0" PIPE BOLARD, TYPICAL SEE 10/PK620 S19 S14 MOUNT ABOVE PAY STATION (ALT) CAR COUNT 9'-0" 90° STANDARD SPACE 8'-9" 65° STANDARD SPACE TIER GROUND HOTEL GROUND PUBLIC SECOND THIRD TOTAL STANDARD CAR ACCESSIBLE VAN ACCESSIBLE TOTAL 80 4 117 114 315 0 2 2 2 6 0 2 0 0 2 80 8 119 116 323 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/10/2016 11:43:26 AM PK101 FLOOR PLAN LEVEL 1 WALNUT ST & CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1FIRST SCALE: 3/32" LEVEL = 1'-0" FLOOR PLAN AUTOMATIC DIMMING VIA PHOTOSENSOR FOR FIXTURES IN DAYLIGHT ZONES. START DIMMING WHEN AMBIENT DAYLIGHT LEVELS EXCEED 5 FC AND DIM TO OFF WHEN AMBIENT DAYLIGHT REACHES 15 FC. DAYLIGHT TRANSITION ZONES FIXTURES TRACK PHOTOSENSOR LOCATED ON PARKING DECK. AUTOMATIC ON TO 100% LIGHT OUTPUT FOR FIXTURES IN DAYLIGHT TRANSITION ZONES WHEN AMBIENT DAYLIGHT LEVELS EXCEED 40 FC. AUTOMATIC OFF FOR FIXTURES IN DAYLIGHT TRANSITION ZONES WHEN AMBIENT DAYLIGHT LEVELS FALL BELOW 20 FC. STAIRWELLS AUTOMATIC ON TO 100% OF FULL OUTPUT FOR ALL STAIRWELL FIXTURES UPON DETECTION OF OCCUPANCY. DIM TO 30% OF FULL OUTPUT FOR ALL STAIRWELL FIXTURES 15 MINUTES AFTER THE LAST DETECTION OF OCCUPANCY. AUTOMATIC OVERRIDE ON TO 100% OF FULL OUTPUT FOR ALL STAIRWELL FIXTURES UPON LOSS OF NORMAL POWER. CONTROLS NARRATIVE LIGHTING CONTROLS LEGEND 1 P XPOINT ENABLED FIXTURE XPOINT ENABLED EMERGENCY FIXTURE XPOINT ENABLED FIXTURE XPOINT ENABLED EMERGENCY FIXTURE CEILING MOUNTED CONTROLS WALL MOUNTED SWITCH SUBSCRIPTS: WALL MOUNTED CONTROLS: O1 = LINE VOLTAGE PIR WALL SWITCH SENSOR LIGHTING CONTROLS NOTES: 1. ALL PART NUMBERS ARE ACUITY BRANDS CONTROLS UNLESS NOTED OTHERWISE. 2. CIRCUIT EXIT SIGNS AND SENSING LEAD FOR EMERGENCY BALLASTS AHEAD OF LOCAL CONTROLS. 3. PRIOR TO SUBMITTING SHOP DRAWINGS, PROVIDE AN ENTIRE SET OF THE MOST UP-TO-DATE ELECTRICAL PLANS TO A FACTORY-AUTHORIZED MANUFACTURER'S REPRESENTATIVE AND ALLOW THE MANUFACTURER'S REPRESENTATIVE TWO WEEKS TO LAY OUT THE LIGHTING CONTROLS SYSTEM ON THE CEILING PLANS, SHOWING DEVICE LOCATIONS FOR ALL SPACES FOR PLACEMENT REVIEW BY THE ENGINEER. 4. PROVIDE RELAY PACKS AS NECESSARY FOR A COMPLETE, OPERATIONAL SYSTEM. #WSX-SA-WH-LT PHOTOCELL: #LCS-624D LOW VOLTAGE STANDARD RANGE PIR: #CM-9 C C C C B B A A A SENSORVIEW D C C C ORANGE BLACK WHITE RED GRAY VIOLET (CAP) B B B B B WHITE BLACK ORANGE BLUE BLUE WIRELESS GATEWAY XPA BRG nLIGHT ETHSW ETHERNET SWITCH nETHSW (5-PORT) WIRELESS GATEWAY XPA BRG WIRELESS GATEWAY XPA BRG XPA SBOR 10 TYPICAL OF TYPE AD TYPICAL OF TYPE A, B nIO PC KIT B B B B B WHITE BLACK ORANGE BLUE BLUE NGWY2 CTRL FIRST FLOOR nGWY2 GFX ETHERNET BASED LOCAL AREA NETWORK USING TCP/IP TO NEXT ETHERNET HUB ETHERNET HUB ***PROVIDED BY OTHERS 1ST FLOOR NPODM4SB NPP16 NPP16 A 2ND FLOOR 3RD FLOOR BUILDING MOUNTED LIGHTS POLE MOUNTED RECEPTACLES TYPICAL OF TYPE AE XPA SBOR 10 EM TYPICAL OF TYPE AES A LAN PS 250 WHITE BLACK A A A TYPICAL OF TYPE A, B TYPICAL OF TYPE AE XPA SBOR 10 EM TYPICAL OF TYPE AES, SCE XPA SBOR 10 EM TYPICAL OF TYPE SAE, SCE LIGHTING CONTROL SCHEME OPERATION 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:34 PM E601 ELECTRICAL DETAILS 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 RECEPTACLE 360 100.00% 360 Total Est. Demand: 4942 Motor 4503 100.00% 4503 Total Conn. Load: 4926 LIGHTING 63 125.00% 79 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 13 A 16 A 13 A Total Load: 1564 1861 1501 41 Spare 20 A 1 0 0 1 20 A Spare 42 39 Spare 20 A 1 0 0 1 20 A Spare 40 37 Spare 20 A 1 0 0 1 20 A Spare 38 35 Spare 20 A 1 0 0 1 20 A Spare 36 33 Spare 20 A 1 0 0 1 20 A Spare 34 31 Spare 20 A 1 0 0 1 20 A Spare 32 29 Spare 20 A 1 0 0 1 20 A Spare 30 27 Spare 20 A 1 0 0 1 20 A Spare 28 25 Spare 20 A 1 0 0 1 20 A Spare 26 23 Spare 20 A 1 0 0 1 20 A Spare 24 21 Spare 20 A 1 0 0 1 20 A Spare 22 19 Spare 20 A 1 0 0 1 20 A Spare 20 17 Spare 20 A 1 0 0 1 20 A Spare 18 15 Spare 20 A 1 0 0 1 20 A Spare 16 13 Spare 20 A 1 0 0 1 20 A Spare 14 11 Spare 20 A 1 0 0 1 20 A Spare 12 9 Spare 20 A 1 0 0 1 20 A Spare 10 7 Spare 20 A 1 0 0 1 20 A Spare 8 5 Spare 20 A 1 0 1501 -- -- -- 6 3 R-TENANT 20 A 1 360 1501 -- -- -- 4 1 LIGHTING 20 A 1 63 1501 3 20 A CU-3 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: SURFACE Wires: 4 Mains Rating: 200 A Supply From: GMDB Phases: 3 Mains Type: MLO Location: Volts: 120/208 Wye A.I.C. Rating: 10000 PANEL: T3 Notes: Spare: 187 A Total Est. Demand: 13 A Total Conn.: 13 A RECEPTACLE 180 100.00% 180 Total Est. Demand: 4798 Motor 4503 100.00% 4503 Total Conn. Load: 4775 LIGHTING 92 125.00% 115 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 13 A 14 A 13 A Total Load: 1593 1681 1501 41 Spare 20 A 1 0 0 1 20 A Spare 42 39 Spare 20 A 1 0 0 1 20 A Spare 40 37 Spare 20 A 1 0 0 1 20 A Spare 38 35 Spare 20 A 1 0 0 1 20 A Spare 36 33 Spare 20 A 1 0 0 1 20 A Spare 34 31 Spare 20 A 1 0 0 1 20 A Spare 32 29 Spare 20 A 1 0 0 1 20 A Spare 30 27 Spare 20 A 1 0 0 1 20 A Spare 28 25 Spare 20 A 1 0 0 1 20 A Spare 26 23 Spare 20 A 1 0 0 1 20 A Spare 24 21 Spare 20 A 1 0 0 1 20 A Spare 22 19 Spare 20 A 1 0 0 1 20 A Spare 20 17 Spare 20 A 1 0 0 1 20 A Spare 18 15 Spare 20 A 1 0 0 1 20 A Spare 16 13 Spare 20 A 1 0 0 1 20 A Spare 14 11 Spare 20 A 1 0 0 1 20 A Spare 12 9 Spare 20 A 1 0 0 1 20 A Spare 10 7 Spare 20 A 1 0 0 1 20 A Spare 8 5 Spare 20 A 1 0 1501 -- -- -- 6 3 R-TENANT 20 A 1 180 1501 -- -- -- 4 1 LIGHTING 20 A 1 92 1501 3 20 A CU-2 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: SURFACE Wires: 4 Mains Rating: 200 A Supply From: GMDB Phases: 3 Mains Type: MLO Location: Volts: 120/208 Wye A.I.C. Rating: 10000 PANEL: T2 Notes: Spare: 187 A Total Est. Demand: 13 A Total Conn.: 13 A RECEPTACLE 180 100.00% 180 Total Est. Demand: 4762 Motor 4503 100.00% 4503 Total Conn. Load: 4746 LIGHTING 63 125.00% 79 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 13 A 14 A 13 A Total Load: 1564 1681 1501 41 Spare 20 A 1 0 0 1 20 A Spare 42 39 Spare 20 A 1 0 0 1 20 A Spare 40 37 Spare 20 A 1 0 0 1 20 A Spare 38 35 Spare 20 A 1 0 0 1 20 A Spare 36 33 Spare 20 A 1 0 0 1 20 A Spare 34 31 Spare 20 A 1 0 0 1 20 A Spare 32 29 Spare 20 A 1 0 0 1 20 A Spare 30 27 Spare 20 A 1 0 0 1 20 A Spare 28 25 Spare 20 A 1 0 0 1 20 A Spare 26 23 Spare 20 A 1 0 0 1 20 A Spare 24 21 Spare 20 A 1 0 0 1 20 A Spare 22 19 Spare 20 A 1 0 0 1 20 A Spare 20 17 Spare 20 A 1 0 0 1 20 A Spare 18 15 Spare 20 A 1 0 0 1 20 A Spare 16 13 Spare 20 A 1 0 0 1 20 A Spare 14 11 Spare 20 A 1 0 0 1 20 A Spare 12 9 Spare 20 A 1 0 0 1 20 A Spare 10 7 Spare 20 A 1 0 0 1 20 A Spare 8 5 Spare 20 A 1 0 1501 -- -- -- 6 3 R-TENANT 20 A 1 180 1501 -- -- -- 4 1 LIGHTING 20 A 1 63 1501 3 20 A CU-1 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: SURFACE Wires: 4 Mains Rating: 200 A Supply From: GMDB Phases: 3 Mains Type: MLO Location: Volts: 120/208 Wye A.I.C. Rating: 10000 PANEL: T1 Notes: Spare: 30 A Total Est. Demand: 70 A Total Conn.: 65 A RECEPTACLE 720 100.00% 720 Total Est. Demand: 25094 LIGHTING 6696 125.00% 8370 Total Conn. Load: 23538 EQUIPMENT 16004 100.00% 16004 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 86 A 62 A 51 A Total Load: 10141 7293 6104 41 Spare 20 A 1 0 0 1 20 A Spare 42 39 Spare 20 A 1 0 0 1 20 A Spare 40 37 Spare 20 A 1 0 0 1 20 A Spare 38 35 Spare 20 A 1 0 0 1 20 A Spare 36 33 Spare 20 A 1 0 0 1 20 A Spare 34 31 Spare 20 A 1 0 0 1 20 A Spare 32 29 Spare 20 A 1 0 0 1 20 A Spare 30 27 -- -- -- 1000 4 1 20 A E-NETWORK POWER SUPPLY 28 25 CAR CHARGER 20 A 2 1000 1000 -- -- -- 26 23 -- -- -- 1000 1000 2 20 A CAR CHARGER 24 21 CAR CHARGER 20 A 2 1000 1000 -- -- -- 22 19 -- -- -- 1000 1000 2 20 A CAR CHARGER 20 17 CAR CHARGER 20 A 2 1000 1000 -- -- -- 18 15 -- -- -- 1000 1000 2 20 A CAR CHARGER 16 13 CAR CHARGER 20 A 2 1000 1000 -- -- -- 14 11 R-LIGHT POLES 20 A 1 720 1000 2 20 A CAR CHARGER 12 9 L-SECOND LEVEL 20 A 1 407 360 1 20 A L-THIRD LEVEL 10 7 L-SECOND LEVEL 20 A 1 1075 1219 1 20 A L-SECOND LEVEL 8 5 L-NORTH STAIRWELL 20 A 1 224 160 1 20 A L-EXTERIOR 6 3 L-FIRST LEVEL 20 A 1 1294 228 1 20 A L-SOUTH STAIRWELL 4 1 L-FIRST LEVEL 20 A 1 1403 444 1 20 A L-FIRST LEVEL 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: SURFACE Wires: 4 Mains Rating: 100 A Supply From: GMDB Phases: 3 Mains Type: MLO Location: ELEC. ROOM 22 Volts: 120/208 Wye A.I.C. Rating: 22000 PANEL: L1 Notes: RECEPTACLE 2340 100.00% 2340 Spare: 88 A Other 180 100.00% 180 Total Est. Demand: 112 A Motor 11828 100.00% 11828 Total Conn.: 111 A LIGHTING 1200 125.00% 1500 Total Est. Demand: 40327 HEATING 11628 100.00% 11628 Total Conn. Load: 40027 EQUIPMENT 12851 100.00% 12851 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 121 A 89 A 132 A Total Load: 13961 10695 15371 59 Spare 0 A 1 0 0 1 0 A Spare 60 57 Spare 0 A 1 0 0 1 0 A Spare 58 55 Spare 0 A 1 0 0 1 0 A Spare 56 53 Spare 0 A 1 0 0 1 0 A Spare 54 51 Spare 0 A 1 0 0 1 0 A Spare 52 49 Spare 0 A 1 0 0 1 0 A Spare 50 47 Spare 0 A 1 0 0 1 0 A Spare 48 45 Spare 0 A 1 0 0 1 0 A Spare 46 43 -- -- -- 1144 0 1 0 A Spare 44 41 ACCU-2/FCU-2 20 A 2 1144 500 1 20 A EMERGENCY CALL BOX 42 39 EMERGENCY CALL BOX 20 A 1 500 500 1 20 A PAY STATION 40 37 PAY STATION 20 A 1 500 1200 1 20 A EXTERIOR SIGNAGE 38 35 EXTERIOR SIGNAGE 20 A 1 1200 1200 1 20 A EXTERIOR SIGNAGE 36 33 -- -- -- 1654 125 1 20 A HEAT TRACE 34 31 -- -- -- 656 563 1 20 A HEAT TRACE 32 29 PANEL LVP THRU UPS 35 A 3 2374 563 1 20 A HEAT TRACE 30 27 PAY STATION 20 A 1 500 500 1 20 A EMERGENCY CALL BOX 28 25 PAY STATION 20 A 1 500 500 1 20 A EMERGENCY CALL BOX 26 23 PAY STATION 20 A 1 500 500 1 20 A EMERGENCY CALL BOX 24 21 AC-1 20 A 1 396 500 1 20 A EMERGENCY CALL BOX 22 19 EF-2 20 A 1 156 1200 1 20 A ELEVATOR LIGHTS 20 17 -- -- -- 1654 1920 1 20 A ESP-1 18 15 UH-2 25 A 2 1654 2506 -- -- -- 16 13 -- -- -- 1456 2506 2 40 A UH-1 14 11 ACCU-1/FCU-1 25 A 2 1456 360 1 20 A R-THIRD FLOOR 12 9 FACP 20 A 1 500 360 1 20 A R-SECOND FLOOR 10 7 -- -- -- 1000 1000 -- -- -- 8 5 GATE MOTOR 20 A 2 1000 1000 2 20 A GATE MOTOR 6 3 EMERGENCY CALL BOX 20 A 1 500 500 1 20 A PAY STATION 4 1 EMERGENCY CALL BOX 20 A 1 500 1080 1 20 A R-FIRST FLOOR 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: SURFACE Wires: 4 Mains Rating: 200 A Supply From: GMDB Phases: 3 Mains Type: MLO Location: ELEC. ROOM 22 Volts: 120/208 Wye A.I.C. Rating: 22000 PANEL: G1 Notes: RECEPTACLE 3780 100.00% 3780 Spare: 367 A Other 180 100.00% 180 Total Est. Demand: 433 A Motor 101425 100.00% 101425 Total Conn.: 427 A LIGHTING 8114 125.00% 10143 Total Est. Demand: 156011 HEATING 11628 100.00% 11628 Total Conn. Load: 153982 EQUIPMENT 28855 100.00% 28855 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 455 A 403 A 433 A Total Load: 54094 48408 51481 41 Spare 0 A 1 0 0 1 0 A Spare 42 39 Spare 0 A 1 0 0 1 0 A Spare 40 37 Spare 0 A 1 0 0 1 0 A Spare 38 35 Spare 0 A 1 0 0 1 0 A Spare 36 33 Spare 0 A 1 0 0 1 0 A Spare 34 31 -- -- -- 1501 0 1 0 A Spare 32 29 -- -- -- 1681 0 1 0 A Spare 30 27 T2 200 A 3 1593 0 1 0 A Spare 28 25 0 1 0 A Spare 26 23 -- -- -- 1501 5044 -- -- -- 24 21 -- -- -- 1861 5044 -- -- -- 22 19 T3 200 A 3 1564 5044 3 100 A ELEVATOR 20 17 -- -- -- 1501 6773 -- -- -- 18 15 -- -- -- 1681 6773 -- -- -- 16 13 T1 200 A 3 1564 6773 3 60 A FC-3 14 11 -- -- -- 6064 6773 -- -- -- 12 9 -- -- -- 7215 6773 -- -- -- 10 7 L1 100 A 3 10141 6773 3 60 A FC-2 8 5 -- -- -- 15371 6773 -- -- -- 6 3 -- -- -- 10695 6773 -- -- -- 4 1 G1 200 A 3 13961 6773 3 60 A FC-1 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: NEMA 1 Indoor MCB Rating: 800 A Mounting: Surface Wires: 4 Mains Rating: 800 A Supply From: Phases: 3 Mains Type: MCB Location: ELEC. ROOM 22 Volts: 120/208 Wye A.I.C. Rating: Use Panel Short Circuit & Refer to... PANEL: GMDB Notes: Spare: 37 A Total Est. Demand: 13 A RECEPTACLE 720 100.00% 720 Total Conn.: 13 A Motor 156 100.00% 156 Total Est. Demand: 4684 HEATING 3308 100.00% 3308 Total Conn. Load: 4684 EQUIPMENT 500 100.00% 500 Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 21 A 5 A 15 A Total Load: 2374 656 1654 11 Spare 20 A 1 0 0 1 20 A Spare 12 9 Spare 20 A 1 0 0 1 20 A Spare 10 7 -- -- -- 1654 0 1 20 A Spare 8 5 UH-3 20 A 2 1654 0 1 20 A Spare 6 3 SECURITY CONTROL PANEL 20 A 1 500 156 1 20 A EF-1 4 1 R-LV ROOM 20 A 1 360 360 1 20 A R-LV ROOM 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: 35 A Mounting: SURFACE Wires: 4 Mains Rating: 50 A Supply From: G1 Phases: 3 Mains Type: MCB Location: SERVER ROOM 21 Volts: 120/208 Wye A.I.C. Rating: 22000 PANEL: LVP MECHANICAL EQUIPMENT CONNECTION SCHEDULE KEY DESCRIPTION LOAD (VA) VOLT FEEDER O.C. PROTECTION C.B. FUSE REMARKS AC-1 AIR COMPRESSOR 396 120 V (2#12+#12G)3/4"C 20A1P - PROVIDE THERMAL OVERCURRENT PROTECTION ACCU-1/FCU-1 MINI-SPLIT 2912 208 V (2#12+#10G)3/4"C 25A2P 20 PROVIDE DISCONNECT ACCU-2/FCU-2 MINI-SPLIT 2288 208 V (2#12+#12G)3/4"C 20A2P 20 PROVIDE DISCONNECT CU-1 CONDENSING UNIT 4503 208 V (3#12+#12G)3/4"C 20A3P 20 PROVIDE DISCONNECT CU-2 CONDENSING UNIT 4503 208 V (3#12+#12G)3/4"C 20A3P 20 PROVIDE DISCONNECT CU-3 CONDENSING UNIT 4503 208 V (3#12+#12G)3/4"C 20A3P 20 PROVIDE DISCONNECT EF-1 EXHAUST FAN 156 120 V (2#12+#12G)3/4"C 20A1P - PROVIDE THERMAL OVERCURRENT PROTECTION EF-2 EXHAUST FAN 156 120 V (2#12+#12G)3/4"C 20A1P - PROVIDE THERMAL OVERCURRENT PROTECTION EL-1 ELEVATOR 15131 208 V (3#4+#8G)1-1/4"C 100A3P 70 PROVIDE DISCONNECT EL-1, LTG ELEVATOR LTG 1200 120 V (2#12+#12G)3/4"C 20A1P 20 PROVIDE DISCONNECT ESP-1 ELEVATOR SUMP PUMP 1920 120 V (2#12+#10G)3/4"C 30A1P 20 PROVIDE DISCONNECT FC-1 FAN COIL 20319 208 V (3#4+#10G)1-1/2"C 70A3P 70 PROVIDE DISCONNECT FC-2 FAN COIL 20319 208 V (3#4+#10G)1-1/2"C 70A3P 70 PROVIDE DISCONNECT FC-3 FAN COIL 20319 208 V (3#4+#10G)1-1/2"C 70A3P 70 PROVIDE DISCONNECT UH-1 UNIT HEATER 5012 208 V (2#8+#10G)1"C 35A2P 30 PROVIDE DISCONNECT UH-2 UNIT HEATER 3308 208 V (2#10+#10G)3/4"C 20A2P 20 PROVIDE DISCONNECT UH-3 UNIT HEATER 3308 208 V (2#10+#10G)3/4"C 20A2P 20 PROVIDE DISCONNECT DESCRIPTION INPUT LOAD INPUT QTY. TYPE CCT CRI VOLTAGE MOUNTING MANUFACTURER, SERIES (B.O.D.) NOTES A 1 LED - 2103 LUMENS 3000 K 80+ LED PARKING GARAGE FIXTURE WITH TWO ENGINES (20 LEDS), 530 mA DRIVE CURRENT, TYPE V MEDIUM DISTRIBUTION, XPOINT WIRELESS ENABLED, AND WHITE FINISH. 37 120 V PENDANT AT 8' 0" A.F.F. LITHONIA LIGHTING D-SERIES PARKING GARAGE #DSXPG LED-20C-530-30K-T5M-120-XAD-DWHXD [1] AD 1 LED - 2103 LUMENS 3000 K 80+ LED PARKING GARAGE FIXTURE WITH TWO ENGINES (20 LEDS), 530 mA DRIVE CURRENT, TYPE V MEDIUM DISTRIBUTION, INTEGRAL XPOINT WIRELESS ENABLED PIR/DAYLIGHT HARVESTING SENSOR, AND WHITE FINISH. 37 120 V PENDANT AT 8' 0" A.F.F. LITHONIA LIGHTING D-SERIES PARKING GARAGE #DSXPG LED-20C-530-30K-T5M-120-PIR3FC3V-XAD-DWHXD [1] AE 1 LED - 2103 LUMENS 3000 K 80+ LED PARKING GARAGE FIXTURE WITH TWO ENGINES (20 LEDS), 530 mA DRIVE CURRENT, TYPE V MEDIUM DISTRIBUTION, XPOINT WIRELESS ENABLED FOR EMERGENCY CIRCUIT, AND WHITE FINISH. 37 120 V PENDANT AT 8' 0" A.F.F. LITHONIA LIGHTING D-SERIES PARKING GARAGE #DSXPG LED-20C-530-30K-T5M-120-XADN-DWHXD [1] AES 1 LED - 2103 LUMENS 3000 K 80+ LED PARKING GARAGE FIXTURE WITH TWO ENGINES (20 LEDS), 530 mA DRIVE CURRENT, TYPE V MEDIUM DISTRIBUTION, INTEGRAL XPOINT WIRELESS ENABLED PIR SENSOR FOR EMERGENCY CIRCUIT, AND WHITE FINISH. 37 120 V PENDANT AT 8' 0" A.F.F. LITHONIA LIGHTING D-SERIES PARKING GARAGE #DSXPG LED-20C-530-30K-T5M-120-PIR-XADN-DWHXD [1] B 1 LED - 7113 LUMENS 3000 K 80+ LED PARKING GARAGE FIXTURE WITH THREE ENGINES (30 LEDS), 1000 mA DRIVE CURRENT, TYPE V ENTRYWAY DISTRIBUTION, XPOINT WIRELESS ENABLED, AND WHITE FINISH. 107 120 V PENDANT AT 8' 0" A.F.F. LITHONIA LIGHTING D-SERIES PARKING GARAGE #DSXPG LED-30C-1000-30K-T5E-120-XAD-DWHXD [1] C 1 LED - 2952 LUMENS 3000 K 80+ 4' LED STAIRWELL FIXTURE WITH 0-10V 1% DIMMING DRIVER STANDARD, NO nLIGHT, XPOINT WIRELESS CONTROLLER, PIR OCCUPANCY & PHOTOCELL SENSOR CONTROL, DIM TO 50% OUTPUT WHEN UNOCCUPIED STANDBY MODE, AND STANDARD WHITE FINISH. 29 120 V SURFACE LITHONIA LIGHTING W SERIES #WL4-30L-EZ1-LP830-XADNS7-DIM50 [1] CE 1 LED - 2952 LUMENS 3000 K 80+ 4' LED STAIRWELL FIXTURE WITH 0-10V 1% DIMMING DRIVER STANDARD, NO nLIGHT, XPOINT WIRELESS CONTROLLER, PIR OCCUPANCY & PHOTOCELL SENSOR CONTROL, DIM TO 50% OUTPUT WHEN UNOCCUPIED STANDBY MODE, INTEGRAL EMERGENCY BATTERY BACKUP, AND STANDARD WHITE FINISH. 29 120 V SURFACE LITHONIA LIGHTING W SERIES #WL4-30L-EZ1-LP830-XADNS7-DIM50-EL14L [1] D 1 LED - 3740 LUMENS 3000 K 80+ 4' LED STRIP LIGHT WITH DROP LENS AND WHITE FINISH. 33 120 V SURFACE LITHONIA LIGHTING Z SERIES #ZL1D-L48-3000LM-FST-120-30K-80CRI-WH DE 1 LED - 3740 LUMENS 3000 K 80+ 4' LED STRIP LIGHT WITH DROP LENS, INTEGRAL EMERGENCY BATTERY BACKUP, AND WHITE FINISH. 33 120 V SURFACE LITHONIA LIGHTING Z SERIES #ZL1D-L48-3000LM-FST-120-30K-80CRI-E7W-WH EXIT 1 LED 3000 K NA LED EXIT SIGN WITH INTEGRAL EMERGENCY BATTERY BACKUP. 5 120 V SEE PLANS LITHONIA LIGHTING WLTE SERIES [2] EXTERIOR LUMINAIRE SCHEDULE TYPE SOURCE DESCRIPTION INPUT LOAD INPUT QTY. TYPE CCT CRI VOLTAGE MOUNTING MANUFACTURER, SERIES (B.O.D.) NOTES SAE 1 LED - 15,340 LUMENS (7670 LM/HEAD) 3000 K 80+ LED AREA LUMINAIRE WITH TWO (2) HEADS, EACH HAVING ONE ENGINE (30 LEDS), 700 mA DRIVE CURRENT, TYPE III MEDIUM DISTRIBUTION, ROUND POLE MOUNTING, 0-10V DIMMING DRIVER, AND WHITE FINISH. PROVIDE ONE XPOINT WIRELESS WET LOCATION MULTI-SENSOR AND CONTROLLER PER POLE AT 10' 0" A.F.G. TO BOTTOM OF SENSOR. 90 120 V POLE AT 20' 0" A.F.G. LITHONIA LIGHTING D-SERIES SIZE 1 AREA LUMINAIRE #(2)DSX1 LED-30C-700-30K-T3M-120-RPA-DMG-DWHXD XPOINT WIRELESS SENSOR: #XPA-SBOR10-WH-EM [1] SCE 1 LED - 2888 LUMENS 3000 K 80+ LED WALL LUMINAIRE WITH ONE ENGINE (10 LEDS), 1000 mA DRIVE CURRENT, TYPE IV MEDIUM DISTRIBUTION, 0-10V DIMMING DRIVER, INTEGRAL EMERGENCY BATTERY BACKUP, HOUSE-SIDE SHIELD, AND WHITE FINISH. PROVIDE ONE INTEGRAL XPOINT WIRELESS WET LOCATION MULTI-SENSOR AND CONTROLLER PER FIXTURE. 40 120 V SURFACE WALL LITHONIA LIGHTING D-SERIES SIZE 1 WALL LUMINAIRE #DSXW1 LED-10C-1000-30K-T4M-120-DMG-ELCW-HS-DWHXD XPOINT WIRELESS SENSOR: #XPA-SBOR10-WH-EM [1] ARCHITECT TO VERIFY ALL FINISHES. [1] FIXTURE FOR USE WITH XPOINT WIRELESS CAPABILITIES. [2] PROVIDE MOUNTING, NUMBER OF FACES, AND DIRECTIONAL CHEVRONS AS INDICATED ON PLANS AND AS REQUIRED TO MEET LOCAL A.H.J. REQUIREMENTS PRIOR TO ORDERING. COORDINATE LETTERING COLOR AND FIELD COLOR WITH LOCAL A.H.J. REQUIREMENTS PRIOR TO ORDERING. ARCHITECT TO VERIFY ALL FINISHES. [1] FIXTURE FOR USE WITH XPOINT WIRELESS CAPABILITIES. [2] PROVIDE MOUNTING, NUMBER OF FACES, AND DIRECTIONAL CHEVRONS AS INDICATED ON PLANS AND AS REQUIRED TO MEET LOCAL A.H.J. REQUIREMENTS PRIOR TO ORDERING. COORDINATE LETTERING COLOR AND FIELD COLOR WITH LOCAL A.H.J. REQUIREMENTS PRIOR TO ORDERING. LOCKABLE IN THE OPEN POSITION. (NEC 620.22, 620.53) SUGGEST HUBBLE "CIRCUIT LOCK" FDS30 FUSED DISC. COORDINATE REQUIREMENTS WITH LOCAL JURISDICTION, SOME REQUIRE SHUNT TRIP OF ELEV. CAB LIGHTING. IF ROOM IS SPRINKLERED MUST BE PROVIDED WITH NEMA 4X RATING PER ASME 17. REFER TO POWER PLAN FOR LOCATION AND QUANTITY. SEPARATE CIRCUIT REQUIRED FOR ELEVATOR CAB LIGHTS AND VENTILATION FOR NEC 620.22. FUSED DISCONNECT. SUGGEST BUSSMAN "POWER MODULE" SWITCH. IF ROOM IS SPRINKLERED SUGGEST TO BE PROVIDED WITH A NEMA 3R DISCONNECT. REFER TO POWER PLANS FOR LOCATION AND QUANTITY. ELEV, P F P F F T X ST ST ST 3 1. PAD MOUNTED TRANSFORMER BY UTILITY COMPANY. 2. ENERGY METER BY UTILITY COMPANY, COORDINATE LOCATION WITH UTILITY COMPANY PRIOR TO INSTALLATION. 3. PROVIDE INDICATED CIRCUIT BREAKER WITH SHUNT TRIP OPERATOR TO INTERFACE WITH FIRE ALARM SYSTEM. 4. PROVIDE E-MON D -MON METER. A. BRACING FOR ALL ELECTRICAL EQUIPMENT TO BE SIZED TO EXCEED SHORT CIRCUIT CALCULATIONS SHOWN ON SHORT CIRCUIT CALCULATION SCHEDULE. B. ARC FLASH CALCULATION AND LABEL TO BE PROVIDED BY CONTRACTOR. 1 2 4 4 4 FEEDER SCHEDULE 600U 2[(3-350KCMIL)2-1/2" PVC] 200Y 100Y 60Y (4#3/0+#6G)2"C (4#1+#8G)1-1/2"C (4#4+#8G)1-1/4"C WIRE AND CONDUIT SIZE - 3∅, 4W 20Y (4#12+#12G)3/4"C 80D (3#3+#8G)1-1/4"C 70D (3#4+#8G)1-1/4"C 50Y (4#6+#10G)1"C 800U 2[(3-600KCMIL)3-1/2"PVC] 1. ONLY DETECTORS AT LANDINGS, AND HOISTWAY SHALL INITIATE ELEVATOR RECALL. DO NOT RECALL UPON GENERAL FIRE ALARM. 2. ELEVATOR RECALL AND SHUT-TRIP SHOULD BE INITIATED VIA THE FACP AND CONTROL MODULES WHICH ALLOWS WIRING TO BE SUPERVISED. 3. IF MACHINE ROOM OR HOISTWAY ARE SPRINKLERED THEN MEANS TO AUTOMATICALLY DISCONECT POWER (SHUNT TRIP) PRIOR TO WATER FLOW IS REQUIRED ASME 17.1-102.2(C)(3). FIRE ALARM NOTES TO ELEV. CONTROLLER FOR CAB LIGHTS (NEC 620.22 & 620.53) b. PER NFPA/ANSI REQUIREMENTS. ELEVATOR RECALL SYSTEM/SHUNT TRIP, SEQUENCE EACH ELEVATOR SHALL BE PROVIDED WITH A COMPLETE ELEVATOR RECALL SYSTEM OF EVENTS, SHALL BE AS FOLLOWS: NOTES: 1. a. F H N COMPLETION OF ELEVATOR RECALL. 120V NORMALLY OPEN CONTACT. PROVIDED WITH "RECALL COMPLETE" CONTACT SHALL CLOSE UPON ELEVATOR CAB CONTROLLER. LTG & RECEPT. LTG AND FAN ELEV CAB MACHINE ROOM ELEVATOR WHEN ASSOCIATED ELEVATOR LOBBY, ELEVATOR MACHINE ROOM, OR ELEVATOR SHAFT SMOKE DETECTOR GOES INTO ALARM, AND UPON A VERIFICATION CYCLE IF USED, THE BUILDING WILL GO INTO GENERAL ALARM AND WILL INITIATE ELEVATOR RECALL. WHEN A THERMAL DETECTOR RATED 190 DEGREES, LOCATED IN THE ELEVATOR MACHINE ROOM IS ACTIVATED, THE SHUNT TRIP ON ELEVATOR MACHINERY WILL TRIP ONLY AFTER THE AUTOMATIC RECALL IS COMPLETE, THUS DISCONNECTING THE POWER TO THE ELEVATOR, MACHINE ROOM LIGHT AND RECEPTACLE, AND ELEVATOR CAB LIGHT AND FAN. THIS CIRCUIT IS INDEPENDENT OF THE FIRE ALARM SYSTEM AND SHALL BE ROUTED VIA THE ELEVATOR CONTROLLER CONTACTS WHICH VERIFY THAT RECALL IS COMPLETE. THE INTENT IS TO DISCONNECT POWER ONLY AFTER THE ELEVATORS HAVE RECALLED TO THEIR ASSIGNED FLOOR, BUT BEFORE WATER FLOWS. TO FACP FOR SHUNT 2. UPON LOSS OF POWER TO SHUNT TRIP, AN ALARM SHALL BE INDICATED AT THE FACP AND REMOTE MONITORING COMPANY. T190° TRIP MONITORING T M PANEL T1 PANEL T2 PANEL T3 PANEL G1 M M M ELEVATOR 100A3P 70A LPN-RK ELEVATOR CONTROLLER PANEL L1 FC-1 60A3P 60A LPN-RK FC-2 60A3P 60A LPN-RK FC-3 60A3P 60A LPN-RK PANEL LVP F F "GMDB" 800A, 120/208V, 3PH, 4W, 65K AIC 120/208V, 3PH, 4W 800A 3P SPD 60A 3P 200A 3P 200A 3P 200A 3P 200A 3P 100A 3P 100A 3P PV SYSTEM 70D 5 INV EM LIGHTING (TYP.3) 20A1P 100Y UPS 50A1P 200A SPACE 200A SPACE 200Y 200Y 200Y 200Y UTILITY CO. PAD MOUNTED TRANSFORMER 120/208V, 3PH, 4W 800U 60Y #2/0 CU TO COLD WATER PIPE #2/0 CU TO BUILDING STEEL #6 CU TO SERVICE ENTRANCE GROUND ROD #4 CU TO CONCRETE ENCASED ELECTRODE N G 60A 3P 70D 9 60A 3P 70D 10 60A 3P 70D 11 50Y 50Y 2 4 6 7 8 1 3 200A 3P CT AND UTILITY METER CABINET ELECTRICAL ONE-LINE DIAGRAM TYPICAL MACHINEROOMLESS ELEVATOR DETAIL TYPICAL ELEVATOR SHUNT TRIP SCHEMATIC FLAG NOTES THIS SHEET: 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:32 PM E401 ELECTRICAL ONE-LINE DIAGRAM 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 G1-37 G1-20 GMDB-20,22,24 210 205 WP G1-41,43 ACCU-2 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:31 PM E203 POWER AND SYSTEMS PLAN LEVEL 3 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1POWER SCALE: 3/32" = 1'-AND 0" SYSTEMS PLAN LEVEL 3 1 GMP/PERMIT SET 13 MAY 2016 FLAG NOTES (THIS SHEET) 200 PROVIDE J-BOX AND CONDUIT FOR EMERGENCY CALL BOX. ROUTE 3/4" CONDUIT FROM INSTALLED J-BOX TO HEAD END EQUIPMENT IN SERVER ROOM. PROVIDE PULL STRING INSIDE CONDUIT. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 201 PROVIDE 120 V POWER CONNECTION FOR PAY STATION. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 203 PROVIDE J-BOX AND CONDUIT FOR SECURITY CAMERA. ROUTE 3/4" CONDUIT FROM INSTALLED J-BOX TO HEAD END EQUIPMENT IN SERVER ROOM. PROVIDE PULL STRING INSIDE CONDUIT. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 205 REFER TO TYPICAL ELEVATOR PIT DETAILS, AND TYPICAL ELEVATOR DETAILS OR ADDITIONAL REQUIREMENTS. 210 INSTALL SECURITY CAMERAS ON LIGHTING POLE WHERE APPLICABLE OR PROVIDE REQUIRED SUPPORT. 211 PROVIDE J-BOX AND 208 V, SINGLE PHASE POWER CONNECTION FOR FUTURE CAR CHARGER. COORDINATE REQUIREMENTS AND EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. GENERAL NOTES: A REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND QUANTITY OF HVAC AND PLUMBING EQUIPMENT. COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. B PROVIDE OUTDOOR, COLD WEATHER LISTED EXIT SIGNS WITH INTEGRAL BATTERY BACKUP AS REQUIRED TO MEET NFPA101 EGRESS PATH SIGNAGE AND LOCAL A.H.J. REQUIREMENTS. ADDITIONAL INFORMATION WILL BE PROVIDED DURING CD PHASE. SYSTEMS GENERAL NOTES: A VERIFY ROUTING AND CIRCUITRY REQUIREMENTS WITH FIRE ALARM SUPPLIER PRIOR TO BID OR ROUGH-IN. B FIRE ALARM CABLE TO BE RUN IN CONDUIT IN ELEVATOR HOISTWAYS, ELECTRICAL ROOMS, MECHANICAL ROOMS, AND SIMILAR AREAS. C NOTIFICATION BOOSTER POWER SUPPLY SHALL HAVE 4 NOTIFICATION APPLIANCE CIRCUITS AND 24 HOURS OF STANDBY AND 5 MINUTES IN ALARM. D ALL NOTIFICATION BOOSTER POWER SUPPLIES MUST BE MONITORED BY THE FACP FOR ALARM, TROUBLE AND SUPERVISORY CONDITIONS. E PROVIDE FIREMEN'S PHONE AND SPEAKER IN ELEVATOR CAR. F LOCATION AND NUMBER OF FIRE ALARM DEVICES ARE SHOWN FOR GENERAL REFERENCE ONLY. CONTRACTOR SHALL PROVIDE A COMPLETE DESIGN APPROVED BY THE FIRE DEPARMENT. NORTH 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:25 PM E202 POWER AND SYSTEMS PLAN LEVEL 2 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1POWER SCALE: 3/32" = 1'-AND 0" SYSTEMS PLAN LEVEL 2 1 GMP/PERMIT SET 13 MAY 2016 FLAG NOTES (THIS SHEET) 200 PROVIDE J-BOX AND CONDUIT FOR EMERGENCY CALL BOX. ROUTE 3/4" CONDUIT FROM INSTALLED J-BOX TO HEAD END EQUIPMENT IN SERVER ROOM. PROVIDE PULL STRING INSIDE CONDUIT. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 201 PROVIDE 120 V POWER CONNECTION FOR PAY STATION. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 203 PROVIDE J-BOX AND CONDUIT FOR SECURITY CAMERA. ROUTE 3/4" CONDUIT FROM INSTALLED J-BOX TO HEAD END EQUIPMENT IN SERVER ROOM. PROVIDE PULL STRING INSIDE CONDUIT. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 211 PROVIDE J-BOX AND 208 V, SINGLE PHASE POWER CONNECTION FOR FUTURE CAR CHARGER. COORDINATE REQUIREMENTS AND EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. 215 PROVIDE 120 V DEDICATED CIRCUIT FOR BUILDING MOUNTED SIGN. COORDINATE ALL POWER AND CONTROL REQUIREMENTS, LOCATION WITH OWNER AND ARCHITECT PRIOR TO INSTALLATION. GENERAL NOTES: A REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND QUANTITY OF HVAC AND PLUMBING EQUIPMENT. COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. B PROVIDE OUTDOOR, COLD WEATHER LISTED EXIT SIGNS WITH INTEGRAL BATTERY BACKUP AS REQUIRED TO MEET NFPA101 EGRESS PATH SIGNAGE AND LOCAL A.H.J. REQUIREMENTS. ADDITIONAL INFORMATION WILL BE PROVIDED DURING CD PHASE. SYSTEMS GENERAL NOTES: A VERIFY ROUTING AND CIRCUITRY REQUIREMENTS WITH FIRE ALARM SUPPLIER PRIOR TO BID OR ROUGH-IN. B FIRE ALARM CABLE TO BE RUN IN CONDUIT IN ELEVATOR HOISTWAYS, ELECTRICAL ROOMS, MECHANICAL ROOMS, AND SIMILAR AREAS. C NOTIFICATION BOOSTER POWER SUPPLY SHALL HAVE 4 NOTIFICATION APPLIANCE CIRCUITS AND 24 HOURS OF STANDBY AND 5 MINUTES IN ALARM. D ALL NOTIFICATION BOOSTER POWER SUPPLIES MUST BE MONITORED BY THE FACP FOR ALARM, TROUBLE AND SUPERVISORY CONDITIONS. E PROVIDE FIREMEN'S PHONE AND SPEAKER IN ELEVATOR CAR. F LOCATION AND NUMBER OF FIRE ALARM DEVICES ARE SHOWN FOR GENERAL REFERENCE ONLY. CONTRACTOR SHALL PROVIDE A COMPLETE DESIGN APPROVED BY THE FIRE DEPARMENT. NORTH J J J J CR CR CR F F J J J M 4 3.7 3 2 1.6 1.3 1 A B C D E F G 5 A.3 F.6 G1 L1 GMDB T1 T2 T3 STORAGE ROOM 5 WP WP, GFI WP, GFI 213 213 200 201 200 201 FACP SECURITY PANEL GFI UPS LTG. INVERTER (TYP. 3) 203 (TYP.) 204 204 205 207 207 207 FC-1 CU-1 CU-2 FC-2 FC-3 CU-3 UH-3 FCU-1 ACCU-1 UH-2 UH-1 WP 208 209 WP AC-1 WP WP 200 215 212 200 EF-1 EF-2 ESP-1 MECH. ROOM 7 LVP-3 G1-2 G1-2 WP, GFI G1-2 G1-2 G1-23 G1-24 G1-6,8 G1-22 G1-38 G1-4 G1-3 G1-5,7 G1-35 G1-1 GFI GFI LVP-1 LVP-2 G1-11,13 G1-14,16 G1-15,17 LVP-5,7 LVP-4 G1-19 G1-18 G1-21 T1-2,4,6 GMDB-2,4,6 T2-2,4,6 GMDB-8,10,12 T3-2,4,6 GMDB-14,16,18 T3-3 T2-3 T1-3 WP, GFI WP, GFI G1-2 G1-2 4'-0"AFF 4'-0"AFF 4'-0"AFF G1-9 HEAT TRACE (TYP. 3) G1-34 G1-32 G1-30 LVP T 214 216 217 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:20 PM E201 POWER AND SYSTEMS PLAN LEVEL 1 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1POWER SCALE: 3/32" = 1'-AND 0" SYSTEMS PLAN LEVEL 1 FLAG NOTES (THIS SHEET) 200 PROVIDE J-BOX AND CONDUIT FOR EMERGENCY CALL BOX. ROUTE 3/4" CONDUIT FROM INSTALLED J-BOX TO HEAD END EQUIPMENT IN SERVER ROOM. PROVIDE PULL STRING INSIDE CONDUIT. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 201 PROVIDE 120 V POWER CONNECTION FOR PAY STATION. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 203 PROVIDE J-BOX AND CONDUIT FOR SECURITY CAMERA. ROUTE 3/4" CONDUIT FROM INSTALLED J-BOX TO HEAD END EQUIPMENT IN SERVER ROOM. PROVIDE PULL STRING INSIDE CONDUIT. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 204 PROVIDE POWER CONNECTION FOR GATE MOTOR. COORDINATE EXACT LOCATIONS, ADDITIONAL ROUGH-IN AND ELECTRICAL POWER INSTALLATION REQUIREMENTS WITH OWNER AND VENDOR. 205 REFER TO TYPICAL ELEVATOR PIT DETAILS, AND TYPICAL ELEVATOR DETAILS OR ADDITIONAL REQUIREMENTS. 207 INSTALL (1) 2" UNDERGROUND CONDUIT FROM ELECTRICAL ROOM TO POTENTIAL RETAIL SPACE. PROVIDE PULL STRING INSIDE CONDUIT. COORDINATE ROUTE WITH OWNER AND ARCHITECT. 208 PROVIDE (2) 3" CONDUITS FOR COMMUNICATION WIRING FROM COMMUNICATION EQUIPMENT ROOM TO PROVIDER SERVICE POINT. VERIFY QUANTITY AND SIZE WITH PROVIDER. COORDINATE EXACT ROUTING WITH OWNER AND ARCHITECT. 209 PROVIDE THREE (3) INVERTERS FOR EMERGENCY LIGHTING BATTERY BACKUP. EVENLITE LITEMINDER SERIES: (3)#LM-52-LC-V1 212 INSTALL (1) 1" CONDUIT FROM ELECTRICAL ROOM TO FUTURE EXTERIOR PARKING GARAGE SIGN LOCATION. PROVIDE 120 V DEDICATED CIRCUIT . COORDINATE ALL POWER AND CONTROL REQUIREMENTS, LOCATION WITH OWNER AND ARCHITECT PRIOR TO INSTALLATION. 213 GATE CARD READER. COORDINATE INSTALLATION REQUIREMENTS WITH GATE VENDOR. 214 ENERGY METER BY UTILITY COMPANY, COORDINATE LOCATION WITH UTILITY COMPANY PRIOR TO INSTALLATION. 215 PROVIDE 120 V DEDICATED CIRCUIT FOR BUILDING MOUNTED SIGN. COORDINATE ALL POWER AND CONTROL REQUIREMENTS, LOCATION WITH OWNER AND ARCHITECT PRIOR TO INSTALLATION. 216 POWERED FROM ACCU-1 UNIT. 217 PROVIDE 10 KVA UPS, EATON 9355 OR EQUAL. COORDINATE ALL REQUIREMENTS WITH OWNER AND AV VENDOR PRIOR TO ORDER. 1 GMP/PERMIT SET 13 MAY 2016 GENERAL NOTES: A REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND QUANTITY OF HVAC AND PLUMBING EQUIPMENT. COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. B PROVIDE OUTDOOR, COLD WEATHER LISTED EXIT SIGNS WITH INTEGRAL BATTERY BACKUP AS REQUIRED TO MEET NFPA101 EGRESS PATH SIGNAGE AND LOCAL A.H.J. REQUIREMENTS. ADDITIONAL INFORMATION WILL BE PROVIDED DURING CD PHASE. SYSTEMS GENERAL NOTES: A VERIFY ROUTING AND CIRCUITRY REQUIREMENTS WITH FIRE ALARM SUPPLIER PRIOR TO BID OR ROUGH-IN. B FIRE ALARM CABLE TO BE RUN IN CONDUIT IN ELEVATOR HOISTWAYS, ELECTRICAL ROOMS, MECHANICAL ROOMS, AND SIMILAR AREAS. C NOTIFICATION BOOSTER POWER SUPPLY SHALL HAVE 4 NOTIFICATION APPLIANCE CIRCUITS AND 24 HOURS OF STANDBY AND 5 MINUTES IN ALARM. D ALL NOTIFICATION BOOSTER POWER SUPPLIES MUST BE MONITORED BY THE FACP FOR ALARM, TROUBLE AND SUPERVISORY CONDITIONS. E PROVIDE FIREMEN'S PHONE AND SPEAKER IN ELEVATOR CAR. F LOCATION AND NUMBER OF FIRE ALARM DEVICES ARE SHOWN FOR GENERAL REFERENCE ONLY. CONTRACTOR SHALL PROVIDE A COMPLETE DESIGN APPROVED BY THE FIRE DEPARMENT. NORTH BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:17 PM E103 LIGHTING PLAN LEVEL 3 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1LIGHTING SCALE: 3/32" = 1'-0" PLAN LEVEL 3 1 GMP/PERMIT SET 13 MAY 2016 FLAG NOTES (THIS SHEET) 100 FOR ELEVATOR PIT LIGHTING, SEE ELEVATOR PIT PLAN ON ELECTRICAL DETAILS SHEET. 103 FIXTURE TO BE ON EMERGENCY BATTERY BACK UP VIA INVERTER 3. SEE POWER PLANS. EVENLITE LITEMINDER SERIES: #LM-52-LC-V1 104 GFCI RECEPTACLE IS PROVIDED WITH METAL WEATHER PROOF IN-USE COVER. RECEPTACLE SHALL BE CONTROLLED WITH THE EXTERIOR POLE FIXTURES. REFERENCE ELECTRICAL DETAILS SHEET FOR ADDITIONAL INFORMATION. GENERAL NOTES: A REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND QUANTITY OF HVAC AND PLUMBING EQUIPMENT. COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. B PROVIDE OUTDOOR, COLD WEATHER LISTED EXIT SIGNS WITH INTEGRAL BATTERY BACKUP AS REQUIRED TO MEET NFPA101 EGRESS PATH SIGNAGE AND LOCAL A.H.J. REQUIREMENTS. ADDITIONAL INFORMATION WILL BE PROVIDED DURING CD PHASE. NORTH 102 102 102 102 102 102 102 B B B B B B B B A A A A A A A AD A A AD A A A A A A A A A A AD 100 DAYLIGHT TRANSITION ZONE EAST DAYLIGHT ZONE WEST DAYLIGHT ZONE NORTH DAYLIGHT ZONE SOUTH DAYLIGHT ZONE SOUTH DAYLIGHT ZONE 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:15 PM E102 LIGHTING PLAN LEVEL 2 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1LIGHTING SCALE: 3/32" = 1'-0" PLAN LEVEL 2 1 GMP/PERMIT SET 13 MAY 2016 FLAG NOTES (THIS SHEET) 100 FOR ELEVATOR PIT LIGHTING, SEE ELEVATOR PIT PLAN ON ELECTRICAL DETAILS SHEET. 102 FIXTURE TO BE ON EMERGENCY BATTERY BACK UP VIA INVERTER 2. SEE POWER PLANS. EVENLITE LITEMINDER SERIES: #LM-52-LC-V1 GENERAL NOTES: A REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND QUANTITY OF HVAC AND PLUMBING EQUIPMENT. COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. B PROVIDE OUTDOOR, COLD WEATHER LISTED EXIT SIGNS WITH INTEGRAL BATTERY BACKUP AS REQUIRED TO MEET NFPA101 EGRESS PATH SIGNAGE AND LOCAL A.H.J. REQUIREMENTS. ADDITIONAL INFORMATION WILL BE PROVIDED DURING CD PHASE. NORTH D L1-1 L1-2 PART 1/3 PART 1/3 L1-2 L1-2 L1-2 L1-2 L1-2 L1-2 L1-2 L1-2 L1-2 L1-2 L1-2 L1-3 L1-4 L1-5 T1-1 T2-1 T3-1 L1-6 PART 2/2 L1-6 PART 1/2 A A A A A A A CE CE C C C B B B B B B B B B B A A A A A A A A A A 101 101 101 101 101 101 101 101 101 101 101 101 100 L1-28 105 DAYLIGHT TRANSITION ZONE EAST DAYLIGHT ZONE WEST DAYLIGHT ZONE NORTH DAYLIGHT ZONE SOUTH DAYLIGHT ZONE SOUTH DAYLIGHT ZONE 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:10 PM E101 LIGHTING PLAN LEVEL 1 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1LIGHTING SCALE: 3/32" = 1'-0" PLAN LEVEL 1 1 GMP/PERMIT SET 13 MAY 2016 FLAG NOTES (THIS SHEET) 100 FOR ELEVATOR PIT LIGHTING, SEE ELEVATOR PIT PLAN ON ELECTRICAL DETAILS SHEET. 101 FIXTURE TO BE ON EMERGENCY BATTERY BACK UP VIA INVERTER 1. SEE POWER PLANS. EVENLITE LITEMINDER SERIES: #LM-52-LC-V1 105 PROVIDE 120V, 15A CIRCUIT FOR NETWORK POWER SUPPLY #PS-250 FOR nLIGHT NETWORK POWER. GENERAL NOTES: A REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND QUANTITY OF HVAC AND PLUMBING EQUIPMENT. COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. B PROVIDE OUTDOOR, COLD WEATHER LISTED EXIT SIGNS WITH INTEGRAL BATTERY BACKUP AS REQUIRED TO MEET NFPA101 EGRESS PATH SIGNAGE AND LOCAL A.H.J. REQUIREMENTS. ADDITIONAL INFORMATION WILL BE PROVIDED DURING CD PHASE. NORTH C MCP - MOTOR CIRCUIT PROTECTION XFMR VFD TTB RVNR NTS NIC MLO WP ZS XP UG WG SR SC PT OL OC NO NL NC - WEATHERPROOF - LIMIT OR POSITION SWITCH - EXPLOSION PROOF - TRANSFORMER - VARIABLE FREQUENCY DRIVE - UNDERGROUND - TELEPHONE TERMINAL BOARD - SAFE OR STOP/RUN - WIREGUARD - REDUCED VOLTAGE, NON-REVERSING - SHORT CIRCUIT - POTENTIAL TRANSFORMER - OVER CURRENT - NOT TO SCALE - OVERLOAD - NORMALLY OPEN - NOT IN CONTRACT - NORMALLY CLOSED - MAIN LUGS ONLY - NIGHT LIGHT CU - COPPER MCC MCA EWC ETM MCB LOR MCCB GRC FWE FLA FVNR FVR HOA ELR LS LT IG LC HP GFI ES EM - LEVEL SWITCH - MOTOR CONTROL CENTER - MOLDED CASE CIRCUIT BREAKER - MINIMUM CIRCUIT AMPS - MAIN CIRCUIT BREAKER - LET THROUGH - LOCAL-OFF-REMOTE - LIGHTING CONTACTOR - ISOLATED GROUND - HAND-OFF-AUTOMATIC - HORSEPOWER - FULL VOLTAGE, NON-REVERSING - FULL VOLTAGE, REVERSING - FULL LOAD AMPS - GALVANIZED RIGID CONDUIT - GROUND FAULT INTERRUPTER - FURNISHED WITH EQUIPMENT - ELAPSED TIME METER - EMERGENCY STOP - ELECTRIC WATER COOLER - END OF LINE RESISTOR - EMERGENCY NOTE: ALL ABBREVIATIONS SHOWN AFG AFF CPT AIC BFG AFC AL CR CT CB AC - ALUMINUM - CIRCUIT BREAKER - CORROSION RESISTANT - BELOW FINISHED GRADE - CURRENT TRANSFORMER - CONTROL POWER TRANSFORMER - ABOVE COUNTER - AMPS INTERRUPTING CURRENT - ABOVE FINISHED CEILING - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE ARE NOT NECESSARILY USED. 1. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. 2. REFER TO THE ARCHITECTURAL PLANS, ELEVATIONS, AND DIAGRAMS FOR LOCATIONS OF THE FLOOR AND WALL DEVICES. IF DEVICES ARE NOT NOTED OTHERWISE THEY SHALL BE MOUNTED LONG AXIS VERTICAL AT THE FOLLOWING HEIGHTS AFF TO CENTER OF DEVICE: SWITCHES +48", RECEPTACLES +18", VOICE/DATA JACKS +18". 3. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY NEW ELECTRICAL SERVICE INSTALLATION OR MODIFICATIONS TO THE EXISTING ELECTRICAL SERVICE WITH THE LOCAL UTILITY COMPANY PRIOR TO STARTING ANY WORK. 4. COORDINATE ALL EQUIPMENT LOCATIONS WITH THE OWNER PRIOR TO ROUGH-IN. COORDINATE THE WIRING DEVICE LOCATIONS WITH THE ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS, AND EQUIPMENT INSTALLATION DRAWINGS. COORDINATE THE LOCATION OF THE MECHANICAL EQUIPMENT WITH THE MECHANICAL PLANS AND THE MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. COORDINATE THE LOCATION OF THE LUMINAIRES WITH THE ARCHITECTURAL REFLECTED CEILING PLANS. 5. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER. 6. ALL 120V BRANCH CIRCUITS SHALL BE 3-WIRE (PHASE,NEUTRAL,GROUND). PHASE, NEUTRAL, AND GROUND CONDUCTORS SHALL BE SIZE 12 AWG UNLESS OTHERWISE NOTED. BRANCH CIRCUITS SHOWN AS A SINGLE HOMERUN SHALL NOT BE COMBINED WITH OTHER CIRCUITS. ALL BRANCH CIRCUITS AND FEEDERS SHALL HAVE EQUIPMENT GROUNDING CONDUCTORS INSTALLED IN THE RACEWAY. 7. PROVIDE (1) 3/4"C WITH BUSHING AND PULL WIRE FROM EACH TELEPHONE, DATA, COMMUNICATION, AND THERMOSTAT OUTLET TO ABOVE THE ACCESSIBLE CEILING, UNLESS NOTED OTHERWISE. 8. THE CONTRACTOR SHALL MAINTAIN FIRE-RATINGS FOR ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED CONSTRUCTION. 9. COORDINATE THE LOCATIONS AND CONTROLS OF ALL APPLICABLE FIRE/SMOKE DAMPERS WITH THE MECHANICAL CONTRACTOR, PRIOR TO CONSTRUCTION. 10. ALL MOUNTING OF ELECTRICAL DEVICES (LUMINAIRES, TRANSFORMERS, PANELS, OUTLETS, CONDUIT RUNS, ETC.) SHALL COMPLY WITH STATE AND LOCAL SEISMIC REQUIREMENTS. ALL LUMINAIRES SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING SUPPORT HANGERS IN COMPLIANCE WITH IBC AND NEC REQUIREMENTS. 11. ADA COMPLIANCE: ELECTRICAL DEVICES PROJECTING FROM THE WALLS WITH THEIR LEADING EDGES BETWEEN 27" AND 80" AFF SHALL PROTRUDE NO MORE THAN 4" INTO WALKWAYS OR CORRIDORS. 12. BACK TO BACK MOUNTING OF RECEPTACLES OR COMMUNICATION OUTLETS IS NOT PERMITTED. THE MINIMUM SEPARATION BETWEEN DEVICES SHALL BE 6" O.C. IN COMMON WALLS AND 24" O.C. IN SOUND-RATED WALLS. 13. GFCI DEVICES SHALL BE PROVIDED AS NOTED AND SHALL COMPLY WITH NEC AND LOCAL REQUIREMENTS. NO FEED-THRU GFCI PROTECTION SHALL BE PERMITTED FOR DOWNSTREAM DEVICES. GFCI DUPLEX RECEPTACLES SHALL BE UL 943 2006 "LOCK-OUT" ACTION OR "NOTIFICATION" COMPLIANT. 14. SWITCHES CONTROLLING LIGHTING LOADS: WHERE SWITCHES CONTROL LIGHTING LOADS SUPPLIED BY A GROUNDED GENERAL PURPOSE BRANCH CIRCUIT, THE GROUNDED CIRCUIT CONDUCTOR (NEUTRAL WIRE) FOR THE CONTROLLED LIGHTING CIRCUIT SHALL BE PROVIDED AT THE SWITCH LOCATION. EXISTING SWITCHES IN REMODELED SPACES SHALL NOT BE EXEMPT FROM THIS REQUIREMENT. 15. WHERE DIMMING CONTROL IS SPECIFIED AS A PORTION OF A CIRCUIT THAT ALSO HAS SWITCHED LIGHTING IN ADJACENT SPACES, PROVIDE A SEPARATE, DEDICATED NEUTRAL WIRE FROM THE DIMMING DEVICE BACK TO THE ORIGINATING PANEL. 16. COORDINATE THE INSTALLATION OF COMMUNICATIONS CABLING, ROUTING, MOUNTING BOXES, AND TERMINATIONS WITH THE OWNER OR IT MANAGER, PRIOR TO CONSTRUCTION. 17. ALL LOW VOLTAGE AND SYSTEMS CABLING LOCATED ABOVE THE ACCESSIBLE CEILING SHALL BE PROPERLY RATED FOR THE APPLICATION. WITHOUT EXCEPTION, ALL CABLING SHALL BE HUNG FROM BRIDLE-TYPE RINGS OR PLACED IN CABLE TRAYS BY THE ELECTRICAL CONTRACTOR. IN EXPOSED CEILING AREAS, ALL CABLING SHALL BE RUN IN CONDUIT TO THE NEAREST ACCESSIBLE CEILING LOCATION. 18. ELECTRICAL DEVICE IDENTIFICATION LABELS: PROVIDE ADHESIVE FILM LABEL, MACHINE PRINTED, IN BLACK, BY THERMAL TRANSFER OR EQUIVALENT PROCESS WITH MINIMUM LETTER HEIGHT OF 3/8" ON ALL ELECTRICAL DEVICES. LABEL SHALL IDENTIFY ORIGINATING PANEL AND CIRCUIT NUMBER IN THE FOLLOWING FORMAT: PANEL-CKT. REFERENCE SPECIFICATIONS FOR ADDITIONAL LABELING REQUIREMENTS. WHERE THE PROJECT SPECIFICATIONS INDICATE MORE STRINGENT LABELING REQUIREMENTS, THOSE REQUIREMENTS SHALL TAKE PRECEDENCE. 19. PROVIDE TYPED UPDATED PANEL DIRECTORIES FOR EXISTING PANELS AFFECTED BY REMODEL WORK. PROVIDE NEW CIRCUIT BREAKER NUMBER IDENTIFICATION AS REQUIRED. 20. ALL EXPOSED CONDUITS SHALL BE ROUTED PERPENDICULAR, PARALLEL AND TIGHT TO COLUMNS AND BEAMS. EXPOSED CONDUIT ROUTING SHALL BE COORDINATED WITH ARCHITECT AND ENGINEER PRIOR TO INSTALLATION. 1. PROVIDE ALL NECESSARY EQUIPMENT AND DEVICES FOR COMPLETE FIRE ALARM SYSTEM PER APPLICABLE CODE REQUIREMENTS. 2. THE LOCATIONS OF SMOKE DETECTORS SHOWN ARE CONSIDERED TO BE SCHEMATIC ONLY. THE ACTUAL LOCATIONS (SPACING TO ADJACENT DETECTORS, DIFFUSERS, WALLS, ETC.) ARE REQUIRED TO MEET NFPA 72. 3. ALL STROBES AND HORN/STROBES SHALL BE SYNCHRONIZED PER NFPA AND LOCAL REQUIREMENTS. 4. THE CONTRACTOR SHALL OBTAIN A STATE REGISTERED ENGINEER TO REVIEW, SEAL, AND SIGN SHOP DRAWINGS FOR PLAN REVIEW SUBMISSION. THE ENGINEER OF RECORD FOR THESE DRAWINGS SHALL NOT SEAL THE FIRE ALARM SHOP DRAWINGS. T165° = COMBINATION, 165°F SUBSCRIPTS: WALL MOUNTED SWITCH CLOSED CIRCUIT TV OUTLET TELEVISION OUTLET MASTER INTERCOM STATION HOUSE PHONE/INTERCOM = DOUBLE POLE = DOOR SWITCH = THERMAL OVERLOAD = LOW VOLTAGE = KEY-OPERATED T DUAL-LEVEL SWITCHES DS LV P = PILOT LIGHT D = DIMMER K SUBSCRIPTS: = 3-WAY = 4-WAY 3 4 2 AMPLIFIER NOTATIONS WALL MOUNTED TELEPHONE OUTLET, +48" AFF = COMBINATION, 190°F TELEPHONE TERMINAL BOARD - TTB CEILING OR WALL MOUNTED CLOCK FLOOR OR WALL MOUNTED MICROPHONE OUTLET WALL MOUNTED TELEPHONE OUTLET FLOOR MOUNTED TELEPHONE AND/OR DATA CEILING OR WALL MOUNTED SPEAKER WALL MOUNTED DATA OUTLET WALL MOUNTED COMBINATION TELEPHONE/DATA REMOTE PILOT LIGHT WITH TEST SWITCH FIREFIGHTERS TELEPHONE JACK SPRINKLER SYSTEM TAMPER SWITCH SPRINKLER SYSTEM FLOW SWITCH SMOKE DETECTOR IN VENTILATING DUCT LIFE SAFETY SPEAKER WITH STROBE = COMPENSATION, 165°F FAN SHUT-DOWN CONNECTION OUTLET BOX, AS NOTED CONNECTION TO PRE-WIRED EQUIPMENT COMMUNICATION SYSTEM SURGE PROTECTIVE DEVICE CONDUIT STUB-OUT - CAP & MARK NO. OF ARROWS INDICATE NO. OF CIRCUITS CIRCUIT HOMERUN TO PANEL OR CABINET, SEALOFF SWITCHING CIRCUIT TURNED UP CIRCUIT TURNED DOWN CONDUIT RUN ENGINE GENERATOR CIRCUITING TRANSFORMER MOTOR CONTROL CENTER PANELBOARD CALL-IN SWITCH TIME-TONE UNIT BUZZER PROGRAM BELL VOLUME CONTROL PAY PHONE OUTLET BOX = SHUNT TRIP = MULTISPEED = VARIABLE FREQUENCY = SOLID-STATE, REDUCED VOLTAGE ENCLOSED CIRCUIT BREAKER, MOLDED-CASE, COMBINATION DISCONNECT AND STARTER FUSED DISCONNECT SWITCH SAFETY DISCONNECT SWITCH SUBSCRIPTS: ST THERMAL-MAGNETIC FIXED SSRV VF MS CONTROL MODULE MONITOR MODULE DAMPER CONNECTION LIFE SAFETY SPEAKER REMOTE PILOT LIGHT MAG. DOOR HOLDER T190° TF165° EXTERIOR POLE MOUNTED LUMINAIRE, AS SCHEDULED EAT = ELECTRONIC ADJUSTABLE TRIP THERMAL-MAGNETIC FIXED ENCLOSED CIRCUIT BREAKER, MOLDED-CASE, ENCLOSED FUSED DISCONNECT SWITCH = SHUNT TRIP = KEY INTERLOCK = CURRENT LIMITING = INSULATED CASE = GROUND FAULT CIRCUIT INTERRUPTER = ZONE-SELECTIVE INTERLOCKING = COMPENSATION, 135°F = COMBINATION, 135°F = IONIZATION FIRE ALARM GRAPHIC PANEL GROUND FAULT PROTECTION CURRENT TRANSFORMER MOTOR, NUMBER INDICATES HORSEPOWER GENERAL ALARM COMBINATION HORN/STROBE FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL CEILING OR WALL MOUNTED DETECTOR = PHOTOELECTRIC OUTLET WITH SPECIAL DEVICE, AS NOTED GENERATOR PEDESTAL OUTLET, AS NOTED WALL MOUNTED OUTLET WITH SPECIAL DEVICE, ABOVE CEILING POWER DISTRIBUTION BOX POKE THROUGH, AS NOTED SURFACE RACEWAY, AS NOTED MAGNETIC MOTOR STARTER FLOOR MOUNTED COMBINATION OUTLET BOX, FLOOR MOUNTED POWER BOX, AS NOTED WALL MOUNTED OUTLET BOX JUNCTION BOX, AS NOTED OUTLET BOX CONNECTION TO MOTOR TELE-POWER POLE PULL BOX CLOCK HANGER OUTLET AS NOTED AS NOTED FIRE ALARM STROBE T TF FIRE ALARM HORN SUBSCRIPTS: MANUAL PULL STATION FIRE ALARM = HOSPITAL GRADE = HOSPITAL GRADE TAMPER RESISTANT = SURGE SUPRRESSION = GROUND FAULT INTERRUPTER = 6" ABOVE COUNTER STRAIGHT BLADE SINGLE RECEPTACLE STRAIGHT BLADE DUPLEX RECEPT. ON EMERGENCY CIRCUIT STRAIGHT BLADE DUPLEX RECEPT. HALF-SWITCHED STRAIGHT BLADE DUPLEX RECEPTACLE STRAIGHT BLADE DOUBLE DUPLEX RECEPT. (FOURPLEX) INSTALL FACES AS INDICATED BY SHADING EMERGENCY LIGHT AS NOTED CEILING OR WALL MOUNTED EXIT SIGN, HG SS AC HGT GFI SUBSCRIPTS: POWER BOLLARD VOLT METER TRANSFER SWITCH AMMETER POWER TRANSFORMER KI ZSI ST GFCI CL IC = ADJUSTABLE INSTANTANEOUS TRIP = MULTISPEED = SOLID-STATE, REDUCED VOLTAGE = VARIABLE FREQUENCY ARE NOT NECESSARILY USED. NOTE: ALL SYMBOLS SHOWN ON LEGEND CIRCUIT BREAKER, MOLDED-CASE, THERMAL-MAGNETIC FIXED MAGNETIC MOTOR STARTER GROUND CONNECTION AS NOTED RECESS MOUNTED LUMINAIRE RECESS MOUNTED LUMINAIRE CEILING OR WALL MOUNTED LUMINAIRE WITH MODULAR WIRING CONNECTOR CEILING OR WALL MOUNTED EXTERIOR LUMINAIRE STRIP LUMINAIRE TRACK LIGHT, AS NOTED OR SCHEDULED DIRECTIONAL ACCENT OR WALL-WASH LUMINAIRE WALL MOUNTED INTERIOR PORCELAIN KEYLESS LUMINAIRE, AS NOTED DOWNLIGHT LIGHTING FUSES SUBSCRIPTS: AT VF MS SSRV SUBSCRIPTS: SCHEMATIC WIRING GRAPHICS DISCONNECT SWITCH METER P = COMBINATION PHOTOELECTRIC AND THERMAL = COMPENSATION, 190°F PT TF190° TVSS - TRANSIENT VOLTAGE SURGE SUPPRESSOR SPD - SURGE PROTECTIVE DEVICE UPPER CASE LETTER AT LUMINAIRES (F1, , ETC.) INDICATES LUMINAIRE TYPE. = TYPE F1 LUMINAIRES IN AREA INDICATED. LOWER CASE LETTER AT LUMINAIRES AND SWITCHES (a, b, ETC.) INDICATE ASSOCIATED UNITS FOR SWITCHING. SHADING WITHIN LUMINAIRE DENOTES "NL" WITHIN LUMINAIRES DENOTES UNIT ON NIGHT LIGHT CIRCUIT. PLUS (+) SIGN WITH DIMENSION AT OUTLET INDICATES HEIGHT ABOVE FINISHED FLOOR OR GRADE TO CENTERLINE OF OUTLET. 3 - 4 - 5 - 2 - 1 - 1 F1 UNIT WITH EMERGENCY BATTERY PACK. ABBREVIATIONS GENERAL NOTES-FIRE ALARM SYSTEMS GENERAL NOTES (FOR ALL ELECTRICAL SHEETS) ELECTRICAL LEGEND Mechanical, Electrical & Energy Consultants 175 North 27th Street, Suite 1312 Billings, MT 59101-2048 406.256.1141 Cheyenne, WY 82001-4368 307.634.7647 500 West 18th Street, Suite 200 Greenwood Village, CO 80111-2518 7600 East Orchard Road, Suite 250-S 303.796.6000 www.mkkeng.com CONSULTING ENGINEERS, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:36:06 PM E000 ELECTRICAL COVER SHEET 165 CHESTNUT ST. FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 TAG WATTS # OF WATTS V-PH CIRCUIT MODEL PER FOOT FEET TOTAL BREAKER HT-1 DCW TO WH AT ROOF 5 25 125 120-1 15A RAYCHEM 5XL-1-CR 1,2,3 -- NOTES: 1. PROVIDE CONNECTION KITS AS REQUIRED. 2. PROVIDE ELECTRONIC AUTOMATIC CONTROLLER. 3. PROVIDE RTD TEMPERATURE SENSORS AS REQUIRED. HEAT TRACE SCHEDULE 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:40:03 PM P501 PLUMBING SCHEDULES 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 CAPPED FOR FUTURE RETAIL AREA. 2" TO STANDPIPES. TYPICAL. WM WM RE: PLANS 70" OUTLET FLOW 46" 48" FINISHED GRADE. MIN 6" CLEAN OUT FLUSH WITH 5" MIN 4" WATER PLUG, TYP. LEVEL 45" 54" 26" 6" FILLET ALL ROUND, TYP. CLEAN OUT TO BE IRON BODY FERRULE WITH BRASS SCREW NOTES: 1'-0" 4" FROM BUILDING 6" MIN 23 2" VENT GRADE 1. 750 GALLON SAND & OIL INTERCEPTOR 2. ALL PIPE AND FITTINGS TO BE CAST IRON, MIN 4" DIA. 3. WALLS AND BOTTOM REINFORCED THROUGHOUT. 4. OUTLET PIPE INVERT TO BE 2" LOWER THAN INLET PIPE. 5. CONSTRUCTION SPECIFICATIONS FOR INTERCEPTOR TO BE PER FT COLLINS WASTE WATER DEP'T. 6. INTERCEPTOR TO BE 60" WIDE. TOTAL VOLUME SHALL BE A MINIMUM OF 100 CU. FT. 5' MIN. FROM BLDG. 4" CLEANOUT DETAILS NO SCALE DOUBLE CLEANOUT DETAIL NO SCALE DOMESTIC WATER PIING ENTRY DETAIL NO SCALE AUTOMATIC ELECTRIC ELEVATOR SUMP PUMP DETAIL NO SCALE WATER ENTRY; COPPER NO SCALE (3" AND SMALLER) FIRE ENTRY; IRON NO SCALE (4" OR LARGER) 6" FLOOR LINE CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH W/TOP OF FLOOR. 16" SQ. CONC. PAD TROWEL SMOOTH & EDGE BRASS CLEANOUT PLUG W/COUNTER SUNK HEAD FINISHED GRADE 1/8 C.I. BEND C.I. WASTE LINE. LENGTH TO SUIT. 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE WASTE LINE CLEANOUT TO GRADE (COTG) BALANCE OF PIPING SAME AS CLEANOUT TO GRADE 1/8 C.I. BEND GRADE CLEANOUT & ACCESS COVER WIRE REINFORCED 30"x18"x8" CONCRETE PAD WIRE REINFORCED CUT OFF FERRULES WALL SLEEVE 4" LARGER I.D. THAN O.D. OF SEWER PIPE WITH WATER PROOF FLANGE CAST-IN PLACE RE: PLBG DWGS FOR SIZES FILL ANNULAR SPACE WITH NON HARDENING, ADHESIVE TYPE WATER & GAS TIGHT SEALANT FOUNDATION WALL TWO WAY CLEANOUT FTG TYLER 003519 4" FTG OR TYLER 003513 6"x6"x4"x4" FTG AS APPROPRIATE OR EQUIVALENT (USE TWO SINGLE WYE CLEANOUT FITTINGS FOR 8" AND LARGER) TO SEWER CUT OFF FERRULES D.I. OR C.I. HUB & SPIGOT PIPE "SV" WEIGHT BFP-1 BACKFLOW PREVENTER. REDUCED PRESSURE PROVIDE HEAT TRACE FROM WATER ENTRY ROOM TO RETAIL SPACES. & ANCHOR TO CONC. 1-1/2"x1-1/2"x1/4" BRACE ON EACH SIDE OF PIPE. CROSS BRACE TIGHT SEAL WATER 96 INTERIOR COVER WITH HANDLE (TYP.) COVER TRAFFIC WEIGHT MANHOLE & 24" ∅ C.I. 24"∅ GRATE ELEVATOR PIT FLOOR PUMP ALARM SENSOR ALARM PANEL NOTE: INSTALL PUMP AND ACCESSORIES PER MANUFACTURERS INSTRUCTIONS FINISHED FLOOR ESP-# F DSN-1 COPPER SERVICE FROM STREET. WALL SLEEVE; I.D. = 4" LARGER THAN O.D. OF PIPE. SEAL BLDG. FLOOR SLAB FOUNDATION WALL OR GRADE BEAM GRADE CAST OR DUCTILE IRON SERVICE FROM STREET. GRADE FOUNDATION WALL OR GRADE BEAM CAST IRON HUB TO FLANGED ADAPTER. FLANGED CAST IRON TO WATER &/OR FIRE SERVICE VALVES. PIPE SLEEVE; CAST IN PLACE. 4" LARGER THAN O.D. OF PIPE. BLDG. FLOOR SLAB CAULK WALL SLEEVE; I.D. = 1" LARGER THAN O.D. OF PIPE. TIE RODS; TYP. THRUST BLOCK WM-1 WM-1 FLOOR CLEANOUT (FCO) CLEANOUT NOT TO BE LOCATED IN CARPETED AREA PIPE SLEEVE; CAST IN PLACE. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:40:03 PM P401 PLUMBING DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:40:02 PM P103 PLUMBING PLAN LEVEL 3 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1THIRD SCALE: 3/32" LEVEL = 1'-0" PLUMBING PLAN FLAG NOTES (THIS SHEET) 204 4" AD-1 AREA DRAIN, TYPICAL. 1 GMP/PERMIT SET 13 MAY 2016 NORTH 3" HT-1 4" F UP & DN. 4" F UP & DN. 4" F UP & DN. 4" F UP & DN. ORD-1 3" 3" RD-1 (275 SF) 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:39:56 PM P102 PLUMBING PLAN LEVEL 2 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1SECOND SCALE: 3/32" = 1'-0" LEVEL PLUMBING PLAN FLAG NOTES (THIS SHEET) 204 4" AD-1 AREA DRAIN, TYPICAL. 216 4" FD-1 FLOOR DRAIN, TYPICAL. 500 4" STANDPIPE WITH FIRE DEPARTMENT CONNECTION. PROVIDE 2-1/2" HOSE CONNECTION AT 48" AFF ON EACH LEVEL. 1 GMP/PERMIT SET 13 MAY 2016 NORTH 103 104 700 302 4" F UP. 500 216 4" F 4" F FDC 6" ST 8" ST 12" ST 8" ST 12" ST 8" ST 10" ST 12" ST 6" ST UP. 6" ST UP. 6" ST UP. 6" ST UP. 6" ST UP. 6" ST UP. 6" ST UP. 6" ST UP. 6" ST DN. 6" ST DN. 4" SO 4" SO 4" ST 4" ST 4" DSN-1 4" DSN-1 6" ST 3/4" DCW 3/4" DCW 3/4" DCW UP. 4" F 106 501 4" SO 4" SO 4" DSN-1 4" DSN-1 4" ST 4" ST 6" ST 502 503 MDF ROOM ELEC. ROOM 3" V UP. 2" V 2" V 217 217 4" DSN-1 4" OST 4" ST 4" ST 4" F UP. 4" F 4" F 4" F 4" F 4" F 4" F 4" F UP. 4" F UP. 4" F 4" F I.E. - 95'-10" I.E. - 96'-0" I.E. - 95'-10" I.E. - 95'-6" I.E. - 96'-4" I.E. - 96'-2" 107 4" SO UP. 4" SO DN. 4" SO UP. 4" SO DN. 4" SO UP. 4" SO UP. 4" SO UP. 4" SO DN. 4" SO UP. 4" SO DN. 4" SO UP. 4" SO UP. 4" SO UP. 4" SO UP. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:39:51 PM P101 PLUMBING PLAN LEVEL 1 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1FIRST SCALE: 3/32" LEVEL = 1'-0" PLUMBING PLAN FLAG NOTES (THIS SHEET) 100 WH-1 WALL HYDRANT. TYPICAL. 101 1" COLD WATER LINE FOR FUTURE TENANT USE. PROVIDE SHUT-OFF VALVE, TYPICAL. 102 1-1/2" INSULATED WATER LINE ROUTED UNDERGROUND FROM WATER ENTRY ROOM TO LOCATION SHOWN. 103 WATER ENTRY ROOM, REFER TO DETAIL. PROVIDE GPM SUB-METERS FOR EACH SET OF RETAIL AREAS (2). 104 1-1/2" MAIN WATER SERVICE. SEE CIVIL FOR CONTINUATION 106 WATER ENTRY. REFER TO DETAIL AND SCHEMATIC. 107 1-1/2" WATER LINE ROUTED UNDERGROUND FROM WATER ENTRY ROOM TO FUTURE RETAIL SPACE AND STUBBED UP AND CAPPED AT BOTH ENDS. FUTURE RETAIL TENANT SHALL MAKE FINAL CONNECTIONS TO WATER METER IN WATER ENTRY ROOM AT TIME OF TENANT BUILD OUT. 202 NEW 4" SANITARY SEWER LINE. SEE CIVIL FOR CONTINUATION. PROVIDE DOUBLE CLEAN OUT AND CAP FOR FUTURE CONNECTION TO FUTURE GREASE TRAP. 205 4" SANITARY WASTE LINE. CAP FOR FUTURE TENANT USE, TYPICAL. 206 4" GREASE WASTE LINE. CAP FOR FUTURE TENANT USE, TYPICAL. 208 FUTURE GREASE TRAP LOCATION. 210 750 GALLON SAND/OIL INTERCEPTOR, SEE DETAIL. PROVIDE (2) 2" VENT LINES FROM SAND/OIL INTERCEPTOR. CONNECT INTO ONE 2" VENT AND TERMINATE PER CODE. 216 4" FD-1 FLOOR DRAIN, TYPICAL. 217 PROVIDE SCORED CONCRETE SLAB TO INDICATE WHERE SANITARY CONNECTIONS ARE TO BE COMPLETED. CONNECTIONS TO ACTIVE MAINS FROM UNUSED LINES MUST BE MAXIMUM 3'-0". 302 12" STORM CONNECTION. REFER TO CIVIL FOR CONTINUATION. 500 4" STANDPIPE WITH FIRE DEPARTMENT CONNECTION. PROVIDE 2-1/2" HOSE CONNECTION AT 48" AFF ON EACH LEVEL. 501 FIRE ENTRY. REFER TO DETAIL AND SCHEMATIC. 502 AREA TO BE SPRINKLED WITH A DRY PIPE SYSTEM PER NFPA 13 LIGHT HAZARD. 503 FUTURE RETAIL SPACE TO BE SPRINKLED WITH A DRY PIPE SYSTEM PER NFPA 13 LIGHT HAZARD. DRY PIPE SYSTEM TO BE STUBBED OUT OF THE MAIN BUT KEPT WITHIN THE WATER ENTRY ROOM. 700 ELEVATOR SUMP PUMP, REFER TO DETAIL. 1 GMP/PERMIT SET 13 MAY 2016 NORTH * WHERE CFM IS INDICATED ON PLANS FOR RETURN AND TRANSFERS, BALANCE TO AIRFLOW INDICATED. SPECIFIC NOTES: 1. PROVIDE SMALLEST FACE AVAILABLE FOR NECK LISTED IN PLANS 2. PROVIDE DAMPER FOR A DUCTED RETURN/TRANSFER AIR SYSTEM THAT REQUIRES AIR BALANCE AT RETURN/TRANSFER OPENINGS AS INDICATED BY AIRFLOW (CFMs) ON DRAWINGS. 3. AS IDENTIFIED ON THE PLANS PROVIDE 12"x24" FACE FOR 10"x22" NECKS, PROVIDE 24"x24" FACE FOR 22"x22" NECKS 4. PROVIDE THE MANUFACTURERS INSULATED SUPPLY PLENUM OVER THE ACTIVE SECTIONS OF THE DIFFUSER UNLESS NOTED OTHERWISE ON THE PLAN. PROVIDE DUCT TRANSITIONS TO ACCOMMODATE ANY PLENUM WITH OVAL DUCT CONNECTIONS. WHERE REQUIRED PROVIDE BLANK-OFF ON NON-ACTIVE SECTIONS. 5. PROVIDE 1" SLOT WIDTH. 6. PROVIDE BACKPAN WHERE CONNECTED TO DUCT OR SOUND BOOT; WHERE NOT DUCT OR SOUND BOOT IS PRESENT PROVIDE PERFORATED PANEL ONLY. 7. FOR THE INLET (NECK) SIZE CALLED FOR ON THE PLAN PROVIDE THE FOLLOWING BACKPAN SIZES: 6" (9x9"), 8" (9x9"), 10" (12x12"), 12" (15x15") GRILLES, REGISTERS, & DIFFUSERS SCHEDULE ITEM TYPE CFM kW AIR MOTOR DATA MANUFACTURER & NOTES CONTROLS EAT LAT MCA V-PH MODEL # F F UH-1 HORIZ. 400 5.0 0.0 45 24.1 208-1 TRANE - UHEC WATER ENTRY ROOM T-STAT UH-2 HORIZ. 400 3.3 10.0 40 15.9 208-1 TRANE - UHEC IDF/MDF ROOM T-STAT UH-3 HORIZ. 400 3.3 10.0 40 15.9 208-1 TRANE - UHEC ELECTRICAL ROOM T-STAT NOTES: 1. PROVIDE WITH UNIT DISCONNECT UNIT HEATER SCHEDULE ITEM SERVICE CFM MAX. S.P. VELOCITY MIN. FREE SIZE MANUFACTURER & NOTES DROP FPM AREA WIDTH HEIGHT MODEL # IN. SQ.FT. IN. IN. SL-1 FC-1 INTAKE/EXHAUST 250 0.05 500 0.50 18 12 RUSKIN ELF6375DX 1 SL-2 FC-2 INTAKE/EXHAUST 250 0.05 500 0.50 18 12 RUSKIN ELF6375DX 1 SL-3 FC-3 INTAKE/EXHAUST 250 0.05 500 0.50 18 12 RUSKIN ELF6375DX 1 SL-4 EF-1 INTAKE/EXHAUST 210 0.17 500 0.42 18 12 RUSKIN ELF6375DX 1 SL-5 EF-2 INTAKE/EXHAUST 210 0.17 500 0.42 18 12 RUSKIN ELF6375DX 1 NOTES: 1. PROVIDE WITH 1/2"X1/2" BIRDSCREEN ON INSIDE FACE AND EXTENDED SILL, BAKED ENAMEL FINISH, COLOR AS SELECTED BY ARCHITECT STATIONARY LOUVER SCHEDULE ITEM SERVICE EVAPORATOR FAN ITEM CONDENSER SECTION COOLING CAPACITY MANUFACTURER NOTES CON- CFM FAN ELECTRICAL ELECTRICAL OP MBH EAT COND SEER & MODEL NO. TROLS TYPE MCA V-PH V-PH MOCP MCA WGT SENS °F TEMP LBS DB/WB °F FCU-1 MDF/IDF ROOM 750 DIRECT -- -- ACCU-1 208-1 25 14.0 155.0 13.5 80/60 95 13.0 CARRIER 38MVC024-3, 40MVC024-3 ALL T-STAT FCU-2 ELEV. CONTROL ROOM 500 DIRECT -- -- ACCU-2 208-1 20 11.0 155.0 10.1 80/60 95 13.0 CARRIER 38MVC018-3, 40MVC018-3 ALL T-STAT NOTES: 1. PROVIDE FIELD DISCONNECT SWITCH, 2. PROVIDE OPTIONAL FILTER BOX AT INLET, 3. PROVIDE PRE-CHARGED LINE SET, 4. PROVIDE WALL MOUNTED THERMOSTAT 5. PROVIDE CONDENSATE PUMP, 6. PROVIDE LOW AMBIENT CONTROL TO -20°F, 7. PROVIDE INDOOR UNIT POWER FROM OUTDOOR UNIT 8. PROVIDE CRANKCASE HEATER, 9. PROVIDE WINTER START CONTROL SPLIT-SYSTEM AIR CONDITIONING UNIT ITEM TYPE SUPPLY FAN MOTOR DATA HEATING CAPACITY COOLING CAPACITY OP MANUFACTURER & NOTES CON- CFM OSA ESP HP V-PH MCA MBH EAT LAT MBH EAT LAT WGT MODEL # TROLS CFM IN °F °F °F °F LBS FC-1 HORZ 1400 250 0.50 3/4 208-3 56.4 27.3 --- --- 38.2 80 50 275 CARRIER - 42BHE12 ALL T-STAT FC-2 HORZ 1400 250 0.50 3/4 208-3 56.4 27.3 --- --- 38.2 80 50 275 CARRIER - 42BHE12 ALL T-STAT FC-3 HORZ 1400 250 0.50 3/4 208-3 56.4 27.3 --- --- 38.2 80 50 275 CARRIER - 42BHE12 ALL T-STAT NOTES: 1. PROVIDE WITH 8kW 2-STAGE ELECTRIC HEATER. 2. PROVIDE 6-ROW DX COOLING COIL. 3. PROVIDE MERV 8 FILTERS. 4. PROVIDE MIXING BOX FAN / BLOWER COIL SCHEDULE ITEM SERVICE MIN CAPACITY ELECTRICAL DATA OP MANUFACTURER NOTES CONTROLS SEER TOT SENS EVAP COND V-PH COMPRESSOR CONDENSER MCA MOCP WGT & MODEL NO. MBH MBH EAT DB/WB EAT RLA LRA RLA LRA LBS CU-1 RETAIL 14 41.0 38.0 80/62 95 208-3 9.0 71 1.2 1.2 12.5 20 200 CARRIER 24AHA436A005 1,2 T-STAT CU-2 RETAIL 14 41.0 38.0 80/62 95 208-3 9.0 71 1.2 1.2 12.5 20 200 CARRIER 24AHA436A005 1,2 T-STAT CU-3 REATIL 14 41.0 38.0 80/62 95 208-3 9.0 71 1.2 1.2 12.5 20 200 CARRIER 24AHA436A005 1,2 T-STAT NOTES: 1. CONTROL SHALL BE PROVIDE VIA FACTORY CONTROLLER PROVIDE WITH FC-1,2,3 2. PROVIDE WITH REFRIGERANT LINE SET, SUCTION LINE FILTERS, ACCESS PORTS, SHUT OFF VALVES, LIQUID LINE FILTER DRYERS, SOLENOID VALVES, SIGHT GLASSES, EXPANSION VALVES AND FLEX CONNECTORS. SEE DETAIL FOR REQUIREMENTS CONDENSING UNIT SCHEDULE ITEM TYPE AREA CFM ESP DRIVE SONES MOTOR DATA OP WT MANUFACTURER CONTROLS SERVED INWC TYPE BHP AMPS RPM V-PH STRTR LBS & MODEL NO. EF-1 CEILING MTD. ELEC. ROOM 210 0.50 DIRECT 5.5 -- 2.3 1500 115-1 -- 20 COOK - GC-184 T-STAT EF-2 CEILING MTD. STORAGE 210 0.50 DIRECT 5.5 -- 2.3 1500 115-1 -- 20 COOK - GC-184 T-STAT NOTES: 1. PROVIDE INTEGRAL DISCONNECT SWITCH, BACKDRAFT DAMPER, VIBRATION ISOLATORS, AND FLEX CONNECTIONS OUTLET. FAN SCHEDULE ROUND DUCT TAKE-OFF FITTINGS NO SCALE LATERAL TAKE-OFF FITTING FLEX DUCT AIR FLOW SPIN-IN FITTING AIR FLOW FLEX DUCT LATERAL TAKE-OFF FITTING W/ MANUAL DAMPER, HANDLE, & LOCK NUT. USE GASKETED FITTING. ATTACH PER MANUFACTURER'S RECOMMENDATIONS. WORM DRIVE S.S. CLAMP (ON INNER LINER) ROUND TWIST-IN FITTING W/ MANUAL DAMPER, HANDLE, & LOCK NUT. USE DUCT SEALANT OR GASKETED FITTING. WORM DRIVE S.S. CLAMP (ON INNER LINER). 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:41:06 PM M501 MECHANICAL SCHEDULES 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 AIR MIN DA RETURN AIR OF STAGES OF VERIFY NUMBER CONTRACTOR TO UNIT AIR COOLED CONDENSING COOLING. REMOTE SEQUENCE OF OPERATION: GENERAL: ALARMS SHALL BE AS NOTED WITHIN THE SEQUENCE OF OPERATION AND THE CONTROL SYSTEM DATA POINT MATRIX. OCCUPIED/UNOCCUPIED CYCLE: THE DDC SYSTEM SHALL MONITOR THE SPACE TEMPERATURES OF THE ROOM. THE STAND ALONE COOLING UNIT LOCATED WITHIN THE ROOM SHALL OPERATE THROUGH IT'S INTERNAL CONTROLS. POINT NAME TYPE ALARM NOTE 2 GRAPHIC NOTE 1 NOTE 3 TREND NOTES SPT - ZONE SPACE TEMP AI 60/85 5 MIN 4 NOTES: 1) NOT ALL VIRTUAL POINTS ARE SHOWN. PROVIDE ALL POINTS REQUIRED FOR SOFTWARE OPERATION. 2) AV (ANALOG VIRTUAL) & BV (BINARY VIRTUAL) 3) POINT SHALL BE DISPLAYED ON THE NOTED SYSTEM GRAPHIC 4) LOCKOUT ALARM WHEN UNIT IS DE-ENERGIZED. PROVIDE 15-MINUTE STARTUP DELAY PRIOR TO ENABLING ALARM. --- NOTE 5 5) OI (ON INDICATION), TREND SHALL NOTE TIME OF BINARY POINT CHANGE SEQUENCE OF OPERATION: SETPOINTS: HEATING SETPOINT: 60 DEG. F (ADJ.) OCCUPIED/UNOCCUPIED CYCLE: ON SENSING A NEED FOR HEAT THE FAN AND ELECTRIC COIL SHALL ENERGIZE AND RUN AS REQUIRED TO SATISFY THE SPACE HEATING SET POINT. T RETURN AIR SEQUENCE OF OPERATION: GENERAL: OUTSIDE AIR AND RETURN AIR DAMPERS ARE PROVIDED AND FIELD INSTALLED BY THE MECHANICAL CONTRACTOR. DAMPER ACTUATOR BY THE CONTROLS CONTRACTOR. THE SPACE TEMPERATURE SENSOR SHALL BE PROVIDED WITH AN OCCUPANT ADJUSTABLE WARMER/COOLER SLIDER AND OCCUPANT OVERRIDE BUTTON. THE SLIDER SHALL ALLOW FOR TEMPERATURE CONTROL OF +/- 2 DEG. F (ADJ.). ALARMS SHALL BE AS NOTED WITHIN THE SEQUENCE OF OPERATION. SETPOINTS: COOLING SETPOINT: 75 DEG. F (ADJ.) UNOCCUPIED COOLING SETPOINT: 85 DEG. F (ADJ.) HEATING SETPOINT: 70 DEG. F (ADJ.) UNOCCUPIED HEATING SETPOINT: 55 DEG. F (ADJ.) UNIT/LIFE SAFETY: THE OUTSIDE AIR AND RELIEF DAMPERS SHALL CLOSE AND THE RETURN AIR DAMPERS SHALL OPEN WHENEVER THE SUPPLY FAN STOPS UNDER ANY CONDITION. UNIT START / STOP CONTROL: IF EQUIPPED AN OCCUPANT OVERRIDE SWITCH WILL CYCLE THE UNIT INTO THE OCCUPIED MODE. OCCUPIED CYCLE: THE SUPPLY FAN SHALL START AND SHALL RUN CONTINUOUSLY. THE OUTSIDE AIR DAMPER SHALL OPEN TO ITS MINIMUM POSITION. THE RELIEF DAMPERS SHALL MODULATE TO MAINTAIN A POSITIVE SPACE PRESSURE OF 0.05 IN.W.C. (ADJ.) RELATIVE TO THE OUTSIDE AMBIENT CONDITIONS. THE SPACE COOLING SET POINT TEMPERATURE SHALL BE MAINTAINED BY MODULATING THE STAGES OF DX COOLING. BEFORE HEATING IS INITIATED, THE CONTROLS SHALL ENTER A NO LOAD BAND. THE SPACE HEATING SET POINT TEMPERATURE SHALL BE MAINTAINED BY THE SCR TYPE ELECTRIC HEATING COIL. THE DISCHARGE AIR TEMPERATURE SHALL BE LIMITED TO A MINIMUM OF 45 DEG. F (ADJ.) AND A MAXIMUM OF 95 DEG. F (ADJ.). UNOCCUPIED CYCLE: THE SUPPLY FAN SHALL BE OFF. THE OUTSIDE AIR AND RELIEF DAMPERS SHALL CLOSE, AND THE RETURN DAMPER SHALL BE OPEN. THE HEATING SHALL BE DISABLED EXCEPT WHEN THE OUTSIDE AIR IS BELOW 35 DEG. F AS DESCRIBED ABOVE. THE COOLING SHALL BE LOCKED OUT. THE SYSTEM SHALL CYCLE THE FAN AND MODULATE THE HEATING TO MAINTAIN THE UNOCCUPIED SPACE HEATING SET POINT. D F SS E C DX C S E C UNIT CONTRLS 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:41:05 PM M401 MECHANICAL CONTROLS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:41:05 PM M103 MECHANICAL PLAN LEVEL 3 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1THIRD SCALE: 3/32" LEVEL = 1'-0" MECHANICAL PLAN FLAG NOTES (THIS SHEET) 106 LOCATION FOR FUTURE EXHAUST DUCT. 107 PROVIDE 12/12 GOOSENECK ON ROOF FOR EXHAUST/RELIEF WITH DAMPER. TYPICAL. 1 GMP/PERMIT SET 13 MAY 2016 NORTH 300 10"ø A 400 4-60 C 400 4-60 C 24/14 300 10"ø A 300 10"ø A 400 4-60 C 400 4-60 C 24/14 24x24 D 24x24 D 24x24 D 24x24 D 10/10 10/10 UH-1 UH-2 UH-3 100 102 103 104 800 700 105 701 703 702 EF-1 STORAGE ROOM 5 MECH. ROOM 7 SERVER ROOM ELEC. ROOM ELEV. RETAIL/OFFICE FLEX SPACE 20/14 20/14 20/14 SL-1 SL-2 SL-3 EF-2 SL-4 SL-5 SL-4 SL-5 701 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:41:00 PM M101 MECHANICAL PLAN LEVEL 1 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1FIRST SCALE: 3/32" LEVEL = 1'-0" MECHANICAL PLAN FLAG NOTES (THIS SHEET) 100 30X12 INTAKE LOUVER WITH 12" PLENUM. ROUTE 10X10 OUTSIDE AIR DUCT TO MIXING BOX. WRAP DUCT WITH 2" INSULATION. TYPICAL. 102 LINEAR SLOT DIFFUSER WITH PLENUM BOX. REFER TO SCHEDULE FOR MORE INFORMATION. TYPICAL. 103 ROUND DUCT TAKE OFF. SEE DETAIL. TYPICAL. 104 LOUVER FACED DIFFUSER. REFER TO SCHEDULE FOR MORE INFORMATION. TYPICAL. 105 PERFORATED RETURN GRILLE. REFER TO SCHEDULE FOR MORE INFORMATION. TYPICAL. 700 FC-# HORIZONTAL FAN COIL WITH MIXING BOX. REFER TO SCHEDULE FOR MORE INFORMATION. TYPICAL. 701 CONDENSING UNIT MOUNTED ON GARAGE WALL TIGHT TO UNDERSIDE OF STRUCTURE. ROUTE REFRIGERANT LINES FROM CONDENSING UNIT TO FAN COIL. REFER TO SCHEDULE FOR MORE INFORMATION. TYPICAL. 702 UNIT HEATER. MOUNT TIGHT TO UNDERSIDE OF STRUCTURE. REFER TO SCHEDULE FOR MORE INFORMATION. TYPICAL. 703 FCU-# DUCTLESS FAN COIL UNIT MOUNTED ABOVE THE DOOR. REFER TO SCHEDULE FORE MORE INFORMATION. TYPICAL. 800 24/7 PROGRAMMABLE THERMOSTAT. MOUNT 60" AFF. TYPICAL. 1 GMP/PERMIT SET 13 MAY 2016 NORTH FIRE DEPARTMENT CONNECTION-WALL TYPE NEW FIRE SPRINKLER O.S. & Y VALVE FIRE PROTECTION F.A. F FS PIPE GUIDE FLOW SWITCH FIRE ALARM FIRE PIPE PIPE EXPANSION JOINT PIPE ANCHOR PIPE UNION PIPE CAP CHILLED WATER RETURN HEATING WATER RETURN HEATING WATER SUPPLY CHILLED WATER SUPPLY CONDENSER WATER SUPPLY CONDENSER WATER RETURN HIGH PRESSURE COND. RETURN DUAL TEMPERATURE RETURN LOW PRESSURE COND. RETURN SHUT OFF VALVE IN RISER DRAIN VALVE W/ HOSE END CONDENSATE PUMP DISCHARGE PLUG OR BALANCING SHUT-OFF VALVE IN RISER DUAL TEMPERATURE SUPPLY FLOW CONTROL VALVE W/ CHECK STRAINER W/ BLOW-OFF VALVE & HOSE END N.O. VALVE W/ LOCKING COVER SAFETY OR RELIEF VALVE PRESSURE REDUCING VALVE PRESSURE - TEMP. TAP TEMPERATURE CONTROL VALVE, 3-WAY TEMPERATURE CONTROL VALVE, 2-WAY PRESSURE GAUGE W/ PIG TAIL & COCK VACUUM BREAKER THERMOMETER MANUAL AIR VENT VALVES & SPECIALTIES RL CHECK VALVE REFRIGERANT LIQUID SHUT-OFF VALVE GLOBE VALVE FLOW INDICATOR FOR FOS RS FOV LPS CP LPR D CHR HPR HPS CS CR CHS LOW PRESSURE STEAM FUEL OIL SUPPLY FUEL OIL VENT FUEL OIL RETURN REFRIGERANT SUCTION HIGH PRESSURE STEAM DRAIN PIPE HWS CWS CWR HWR PIPING 2-WAY VALVES 2 POSITION 3-WAY & 2-WAY VALVES MODULATING 3-WAY & LOW TEMPERATURE DUCT SMOKE DETECTOR DAMPER ACTUATOR TEMPERATURE CONTROL END SWITCH EMERGENCY PULL SWITCH REFRIGERENT DETECTOR FLOW SWITCH DETECTION THERMOSTAT EMER ES FS SSWITCH DA GAUGE LT 2P M 2P M OUTPUT SYMBOL BINARY INPUT OR XXX XXX OUTPUT SYMBOL ANALOG INPUT OR CURRENT TRANSFORMER DIFFERENTIAL PRESSURE XXX XXX DP CT HI LOW SENSOR MAIN AIR CONTROL AIR PIPING CONTROL WIRING BUTTERFLY BUTTERFLY 2-WAY VALVE BFV VALVE 3-WAY STARTER MOTOR BFV COIL FILTER FAN M PUMP FLOW SENSOR/CONTROLLER DUCT AVERAGING TEMPERATURE ROOM THERMOSTAT/TEMP SENSOR WATER TEMPERATURE SENSOR SENSOR/CONTROLLED WATER DIFFERENTIAL PRESSURE CARBON DIOXIDE SENSOR CARBON MONOXIDE SENSOR SNOW/ICE SENSOR HUMIDISTAT/HUMIDITY SENSOR BUILDING STATIC PRESSURE SENSOR PRESSURE SENSOR DUCT STATIC BSD T HI LO WITH WELL LO DSP PS LU HI HI LO T T SENSOR H REMOTE BULB DAMPER (T.C.) (SYMBOLS LOCATED IN TC SCHEMATICS) WORK STATION OPERATORS TERMINAL CPU COMPUTER UNIT MONITOR MOD MODEM PRINTER LAP TOP HAND HELD CALIBRATED BALANCING SHUT-OFF VALVE. PREMANUFACTURED PIPE EXPANSION LOOP. REQUIRED EXPANSION COMPENSATION LISTED. PROVIDE GUIDES & ANCHORS AS RECOMMENDED BY MANUFACTURER. PRESSURE INDEPENDENT 2-WAY CONTROL VALVE PRESSURE INDEPENDENT AUTOMATIC BALANCING VALVE PROJECT LOCATION: FORT COLLINS, COLORADO PROJECT ALTITUDE: 5,000 FEET ABOVE SEA LEVEL SUMMER DESIGN TEMPERATURE: 90.1°F DRY BULB, 60.9°F WET BULB (ASHRAE 0.4% DESIGN) WINTER DESIGN TEMPERATURE: -2.6°F DRY BULB, 0%RH (ASHRAE 99.6%) SUMMER ROOM DESIGN TEMP: 75°F DRY BULB - NO HUMIDITY REQUIREMENT WINTER ROOM DESIGN TEMP: 70°F DRY BULB - NO HUMIDITY REQUIREMENT SUMMER ROOM SETBACK TEMP: 90°F DRY BULB - NO HUMIDITY REQUIREMENT (ASHRAE 90.1) WINTER ROOM SETBACK TEMP: 55°F DRY BULB - NO HUMIDITY REQUIREMENT (ASHRAE 90.1) AUTOMATIC AIR VENT RD REFRIGERANT DISCHARGE 1. INFORMATION ON THE DRAWINGS HAS BEEN ASCERTAINED FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. THIS INFORMATION IS AS ACCURATE AS CONDITIONS WOULD ALLOW. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE, PRIOR TO BID, AND BECOME FAMILIAR WITH THE EXTENT OF THE WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY CONTRACT DOCUMENTS. 2. CONTRACTOR IS TO PROVIDE COMPLETE CONNECTIONS TO ALL EQUIPMENT. 3. CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING, COORDINATE ANY EQUIPMENT DOWNTIME, AND COORDINATE GENERAL WORK SCHEDULE WITH THE PROPERTY MANAGER. 4. CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING BID, AND VERIFY DIMENSIONS AND EXISTING CONDITIONS RELATED TO THE WORK. 5. ALL CUTTING, PATCHING AND CORE DRILLING FOR THE INSTALLATION OF NEW EQUIPMENT, DUCTS, HANGERS, ETC. SHALL BE HELD TO A MINIMUM AND BE ACCOMPLISHED IN A CAREFUL MANNER. 6. CONTRACTOR TO COORDINATE THE LOCATION OF ALL DUCTWORK, CEILING DEVICES, GRILLES, REGISTERS AND DIFFUSERS WITH REFLECTED CEILING PLAN AND STRUCTURE PRIOR TO BEGINNING WORK. 7. DUCT DIMENSIONS GIVEN ARE OUTSIDE SHEET METAL DIMENSIONS. 8. MECHANICAL DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY INDICATE EVERY REQUIRED OFFSET, FITTING, ETC. DRAWINGS ARE NOT TO BE SCALED FOR DIMENSIONS. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS AND FROM THE STRUCTURE ITSELF BEFORE FABRICATING ANY WORK, VERIFY ALL SPACE REQUIREMENTS COORDINATING WITH OTHER TRADES, AND INSTALL THE SYSTEMS IN THE SPACE PROVIDED WITHOUT EXTRA CHARGES TO THE OWNER. 9. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR TO MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM HIS WORK. 10. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE CODES, LOCAL CODES AND OWNER'S STANDARDS INDICATED BY THE CONSTRUCTION DOCUMENTS. 11. ALL EXTERIOR WALL AND ROOF PENETRATIONS SHALL BE SEALED WATERPROOF. 12. ALL MECHANICAL WORK UNDER THIS CONTRACT IS TO FIVE (5) FEET OUTSIDE THE BUILDING. 13. XX-## REFERS TO EQUIPMENT DESIGNATION. SEE SPECIFICATIONS AND EQUIPMENT SCHEDULES FOR FURTHER INFORMATION IN REFERENCE TO THAT DESIGNATED PIECE OF EQUIPMENT. DOMESTIC HOT WATER ( TEMP. SHOWN ) STORM DRAIN/ BUILDING STORM SEWER PIPE (1) SHEET NO. WHERE SHOWN. SECTION CUT: (A) SECTION I.D. POINT OF PIPE CONNECTION NEW TO EXISTING POINT OF DUCT OR PIPE CONNECTION NEW TO EXISTING U.C. 1" UNDERCUT DOOR, 1". MISCELLANEOUS A 1 CONTROLS (IN PLAN) DIFFERENTIAL AIR PRESSURE SENSOR PRESSURE DIFFERENTIAL SENSOR LOW LIMIT THERMOSTAT TEMPERATURE CONTROL (T.C.) DAMPER SMOKE DETECTOR (DUCT) FLOW METER SWITCH PRESSURE SWITCH HUMIDISTAT/SENSOR NIGHT THERMOSTAT THERMOSTAT/TEMP SENSOR STARTER FLEXIBLE DUCT HORIZONTAL CLEANOUT HVAC DUCTWORK 24/12 BACKDRAFT DAMPER FLEXIBLE CONNECTION SUPPLY AIR DUCT DOWN OA, RA OR EXH DUCT DOWN UP VERTICAL CLEANOUT COMBINATION FIRE / SMOKE DAMPER OPPOSED BLADE DAMPER ( O.B.D. ) TURNING VANES SHOWN IN 90° ELBOW. SMOKE DAMPER FS FIRE DAMPER S T PLUMBING NP V SAN CHV GW CHW CA SO OST ST NG TEMPERED WATER NON-POTABLE WATER OVERFLOW STORM DRAIN PIPE CHEMICAL VENT PIPE SANITARY WASTE PIPE GREASE WASTE PIPE CHEMICAL WASTE PIPE PLUMBING VENT PIPE COMPRESSED AIR PIPE SAND/OIL WASTE NATURAL GAS DOMESTIC HOT WATER CIRCULATING DOMESTIC COLD WATER DOMESTIC HOT WATER 180 D - DOUBLE WALL CONSTRUCTION UL - UNLINED DUCTWORK V - OVAL DUCTWORK DUCT SIZES ARE OUTSIDE SHEET METAL DIMENSIONS. 1st NO. IS SIZE OF SURFACE SHOWN. 2nd NO. IS DUCT DEPTH. LETTERS AFTER DIM. CORRESPOND TO FOLLOWING: ø - ROUND DUCTWORK SUPPLY DIFFUSER. ALL DIFFUSERS FOUR-WAY THROW UNLESS NOTED OR THROWS SHOW IN PLAN. SEE SCHEDULE FOR TYPE. RETURN/TRANSFER/EXHAUST AIR TAG. SEE SCHEDULE FOR TYPE. SECTION THRU OUTSIDE AIR INTAKE OR SUPPLY AIR DUCT SECTION THRU RETURN AIR OR EXHAUST DUCT CHANGE OF ELEVATION UP (UP) DOWN (DN) IN DIRECTION OF AIR FLOW RETURN AIR GRILLE W/SOUND BOOT SHADING INDICATES OPEN END REFERENCE DESIGNATION FOR PLUMBING ISOMETRIC AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE ALT ALTITUDE BHP BRAKE HORSEPOWER BTU BRITISH THERMAL UNIT C COMMON PORT CFM CUBIC FEET PER MINUTE SCFM CFM, STANDARD CONDITIONS CU FT CUBIC FEET CU IN CUBIC INCH Cv COEFFICIENT, VALVE FLOW dB DECIBEL DB DRY BULB DCW DOMESTIC COLD WATER DEG OR ° DEGREE DHW DOMESTIC HOT WATER DIA DIAMETER DN DOWN (E) EXISTING EAT ENTERING AIR TEMP. EFF EFFICIENCY ELEV ELEVATION ESP EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMP. EXH EXHAUST F FAHRENHEIT FLA FULL LOAD AMPS FPM FEET PER MINUTE FPS FEET PER SECOND FT FOOT, FEET, FEET WATER COLUMN FU FIXTURE UNITS GA GAUGE GAL GALLONS GPH GALLONS PER HOUR GPM GALLONS PER MINUTE HD HEAD HG MERCURY HGT HEIGHT HORZ HORIZONTAL HP HORSEPOWER HR HOUR(S) HWC HOT WATER CIRCULATING (DOMESTIC) HZ HERTZ ID INSIDE DIAMETER IE INVERT ELEVATION IJS IN JOIST SPACE IN INCHES IN W.C. INCHES IN INCHES WATER COLUMN KW KILOWATT KWH KILOWATT HOUR LAT LEAVING AIR TEMPERATURE LBS OR # POUNDS LF LINEAR FEET LRA LOCKED ROTOR AMPS LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MBH BTU PER HOUR (THOUSAND) MCA MINIMUM CIRCUIT AMPS MIN MINIMUM N/A NOT APPLICABLE N.C. NORMALLY CLOSED N.O. NORMALLY OPEN NC NOISE CRITERIA NIC NOT IN CONTRACT NO OR # NUMBER NTS NOT TO SCALE OA OUTSIDE AIR OD OUTSIDE DIAMETER % PERCENT PH OR ∅ PHASE (ELECTRICAL) PPM PARTS PER MILLION PRESS PRESSURE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSIA PSI ABSOLUTE PSIG PSI GAUGE RA RETURN AIR RECIRC RECIRCULATE RH RELATIVE HUMIDITY RLA RUNNING LOAD AMPS RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SENS SENSIBLE SL SEA LEVEL SP STATIC PRESSURE SPEC SPECIFICATION SQ SQUARE STD STANDARD TD TEMPERATURE DIFFERENCE TEMP TEMPERATURE THRU THROUGH TJO THROUGH JOIST OPENINGS TONS TONS OF REFRIGERATION TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TYP TYPICAL V VOLT VAV VARIABLE AIR VOLUME VEL VELOCITY VERT VERTICAL VOL VOLUME W WATT WB WET-BULB WPD WATER PRESSURE DROP WT WEIGHT W/SETPOINT ADJUSTMENT W/TEMP INDICATION W/TEMP AND ADJUSTMENT W/STAINLESS STEEL COVER SUBSCRIPTS: W/LOCKING GUARD NIGHT S - A - I - AI - G - N - VFD VARIABLE FREQUENCY DRIVE AIR FLOW MEASURING FLOW STATION PLUG VALVE. BALL VALVE TEMP SENSOR W/STAINLESS STEEL COVER TEMP SENSOR W/SETPOINT ADJUSTMENT TEMP SENSOR W/TEMP INDICATION TEMP SENSOR W/SET POINT ADJUSTMENT AND TEMP INDICATION THERMOSTAT/TEMP SENSOR WITH LOCKING GUARD CARBON DIOXIDE SENSOR CARBON MONOXIDE SENSOR NITROGEN DIOXIDE SENSOR NITROGEN DIOXIDE SENSOR SIZE CFM X CONSULTING ENGINEERS, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER BOHEMIAN COMPANIES 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 5/12/2016 1:40:56 PM M000 MECHANICAL COVER SHEET 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP/PERMIT SET 13 MAY 2016 2" EQ EQ EQ EQ 2" 16"x16" CONC. PILASTER 4 4 2 1.6 1.3 1.3 1 1 3.7 3.7 3 A A B C D E F F G A.3 5 F.6 A.4 NOTES: 1. ALL SHEARWALLS FORCES INDICATED ARE STRENGTH LEVEL SEISMIC SHEARS, 'EQ' (KIPS) AND STRENGTH LEVEL WIND SHEARS, 'WL' (KIPS) APPLIED TO THE SHEARWALL BY THE FLOOR DIAPHRAGM AT THE LEVEL INDICATED. BOTH STORY SHEARS (NOTED V) AND CUMULATIVE SHEARS (NOTED ∑V ) ARE INDICATED. OVER-TURNING MOMENTS (KIP-FT) ARE FOR REFERENCE ONLY AND ONLY PROVIDE INFORMATION ON MAXIMUM MOMENT LOCATION. SHEARWALLS SHALL BE DESIGNED FOR THE MAXIMUM SHEAR AND MOMENT TO OCCUR ANYWHERE ALONG THE HEIGHT OF THE WALL. 2. ALL SHEARWALL FORCES ARE CALCULATED IN ACCORDANCE WITH THE 2012 IBC. REFER TO THE 2012 IBC (SECTION 1605.2) FOR REQUIRED LOAD COMBINATIONS. 3. SIGNS OF SHEARWALL FORCES INDICATE RELATIVE DIRECTIONS ONLY. SHEARWALLS SHALL BE DESIGNED FOR FORCES IN BOTH DIRECTIONS. 4. COMPATIBILITY OF WALLS AT CORNERS WAS NOT CONSIDERED IN THE CALCULATION OF THE ABOVE FORCES. 5. THE FORCES GIVEN ABOVE DO NOT INCLUDE GRAVITY DEAD OR LIVE LOADS. THE PRECAST MANUFACTURER MUST INCORPORATE GRAVITY DEAD AND LIVE LOADS IN THE DESIGN OF THE WALLS. 6. IF VERTICAL PANEL JOINTS NOT SHOWN IN THE SHEARWALL ELEVATIONS ARE REQUIRED FOR SHIPPING OR ERECTION PURPOSE. THE PRECAST MANUFACTURER SHALL DESIGN THE JOINT SO THAT PANELS ACT AS ONE CONTINUOUS WALL. 7. ALL 9" THICK PRECAST LITEWALLS SHALL BE DESIGNED FOR THE SPECIFIED FORCES AND MOMENTS. SEE THIS SHEET FOR LITEWALL ELEVATIONS. 8. ALL LOADS PROVIDED ARE FOR 1.0E OR 1.0W (STRENGTH LEVEL FORCES). 9. DESIGN ALL DIAPHRAGM TO SHEAR WALL / LITE WALL CONNECTIONS FOR A CAPACITY OF 3.82 KLF (STRENGTH LEVEL) PRECAST SHEARWALL DESIGN FORCE SCHEDULE WALL 'A' V ∑V ∑M V ∑V ∑M -- -- 374 864 1823 4056 35 81 71 158 71 158 35 81 36 77 -- -- -- -- 32 96 154 488 3 9 6 19 6 19 3 9 3 10 -- -- LEVEL LEVEL 2 LEVEL 3 LEVEL 1 (BASE) WL EQ WL WL EQ EQ LATERAL FORCE (KIPS) & OVER TURNING MOMENT (KIP-FT) WALL 'B' Level 3 125' - 8" Level 2 115' - 0" Level 1 100' - 0" B C D E F 103' - 6" T.O.W. 98' - 8" B.O.W. 1'-5 1/2"5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0" 6'-2 1/2" 4" 8" 8'-6" 10'-0" 20'-0" 10'-0" 10'-0" 106' - 5" 105' - 5" 104' - 5" 102' - 5" 101' - 5" 100' - 5" T.O.W. T.O.W. T.O.W. T.O.W. T.O.W. T.O.W. 6'-0" 96' - 0" B.O.W. TYP. P/C LITE WALL DIMS. 2'-0" 6'-0" 4'-0" 6'-0" 4'-0" 6'-0" 4'-0" 6'-0" 2'-0" 160'-0" 40'-0" 40'-0" 40'-0" 40'-0" PV SUPPORT FRAME POST LOC'S 5'-0" 15 SP. @ 10'-0" = 150'-0" 5'-0" 9 S-202 Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:49 PM S-411 RAMP WALL ELEVATIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-101 S-411 3/32" = 1'-0" 2 RAMP WALL (LITE WALL) ELEVATION AT GRID 3 S-103 S-411 1/2" = 1'-0" 3 PHOTO VOLTAIC SUPPORT FRAME S-411 S-411 1" = 20'-0" 4 SHEAR WALL PLAN 3/32" = 1'-0" RAMP WALL (LITE WALL) ELEVATION AT GRID 2 2 S-203 S-203 3 S-203 3 O.H. 10 S-202 102' - 6" 102' - 5" STEP T.O. WALL STEP T.O. WALL STEP T.O. WALL 103' - 6" T.O. WALL 1'-0" 1'-0" 9 1/2" 7 1/2" 101' - 10" T.O. PILASTER 2 S-203 10 S-202 10 S-202 10 S-202 101' - 0" 5'-4" 4" 4'-6" 10" 5 S-203 99' - 0" 97' - 6" B.O. WALL B.O. WALL HSS4x4x3/8 T.O. STEEL = 100' 9 1/2" 107' 1" 115' 1" 120' 7" 127' 6" 139' 5" CONNEC TO PRECAST PER 12/S-302 DESIGN PER ELEV. MNF. REQUIRED LOADS 2'-1 5/8" 4 3.7 F G C8x13.7 HSS8x6x3/8 C8x13.7 C8x13.7 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 C8x13.7 HSS8x6x3/8 T.O. STEEL 2 S-310 HSS8x6x3/8 HSS8x2x1/4 HSS8x6x1/2 HSS8x6x1/2 110' - 10 1/2" 18'-4" 4'-7 1/8" 4'-3 1/2" 4'-3 1/2" 4'-3 1/2" 4'-3 1/2" 4'-4 1/2" 4'-3" 4'-5 3/4" 11'-5 1/4" 2'-9 5/8" 4'-6 7/8" 3'-8 7/8" 6'-5 5/8" 9" W8X10 W10x22 W8X10 W10x22 114' - 5" 5 S-302 S-310 3 1 S-310 6 S-302 10 S-302 4'-10 1/4" HSS14x6x3/8 HSS14x6x3/8 HSS8x6x1/4 HSS14x6x3/8 HSS14x6x3/8 114' - 5 1/2" 110' - 10 1/2" HIGH LOW HIGH LOW HIGH LOW 114' - 0" T.O. STEEL HIGH T.O. STEEL LOW T.O. STEEL HIGH LOW 11 S-302 12 S-302 11'-9 7/8" PROVIDE 1/4" BENT PL AT EDGE OF SLAB 3" CONC. ON 2" COMPOSIT E DECK CONNECTION TO P/C/ PER 10/S-302 HSS8X6X1/4 LANDING T.O.S. = 107' 8 1/2" 4 3.7 F G HSS14x6x3/8 HSS14x6x3/8 W8X10 W10x22 W10x22 5 S-302 S-310 3 1 S-310 6 S-302 10 S-302 11 S-302 12 S-302 39'-0" 2'-8 5/8" 9'-3 7/8" 9'-5 1/8" 7'-4 1/2" 10'-2 1/2" 9" 18'-4" 125' - 1" 125' - 1" T.O. STEEL T.O. STEEL 3" CONC. ON 2" COMPOSIT E DECK 125' - 1 1/2" HSS14x6x3/8 HSS8X6X1/4 LANDING T.O.S. = 119' 3 3/8" 4 3.7 F G 3N 18 GA. ROOF DECK 136' - 0 3/8" 136' - 3" HSS10x6x3/8 W10x22 W10x22 W10x22 W10x22 HSS10x6x3/8 HSS10x6x3/8 1.5B 18 GA. ROOF DECK 8 S-302 8 S-302 7 S-302 S-310 3 11 S-302 39'-0" 3'-1 5/8" 7'-4 1/2" 18'-4" 1.3 1 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 C8x11.5 C8x13.7 C8x13.7 C8x13.7 111' - 8" T.O. STEEL HSS8x6x1/4 2 S-310 A.4 HSS8x2x1/4 W8X10 HSS14x6x3/8 11 S-302 SIM. S-310 3 1 S-310 HSS14x6x3/8 HSS8x6x1/4 HIGH LOW HIGH LOW 114' - 5 1/2" 111' - 8" T.O. STEEL HIGH T.O. STEEL 114' - 5" LOW T.O. STEEL 3" CONC. ON 2" COMPOSITE DECK 6 S-302 SIM. 10 S-302 114' - 0" 7 1/4" 16'-3" 7'-8 1/4" 3'-10" 11 7/8" 3'-7 3/8" HSS14x6x3/8 HSS8X6X1/4 LANDING T.O.S. = 108' 4 1/8" SIM. 3'-3 7/8" 3'-3 7/8" 3'-3 7/8" 3'-3 7/8" 3'-3 7/8" 3'-3 7/8" 4'-7 1/4" 1.3 1 104' - 2" 102' - 6 1/2" 16'-3" 4'-1 1/2" 3'-1" A.4 103' - 3 1/2" 2 S-203 1'-11" 5 1/4" 3'-4" 7 S-202 2 S-203 T.O. WALL T.O. WALL 8 S-202 8 S-202 STEP T.O. WALL 2'-3" 7'-11" 9'-9 1/2" 9'-8 1/2" 1'-2 7/8" 1.3 1 A.4 HSS14x6x3/8 W8X10 HSS14x6x3/8 11 S-302 SIM. S-310 3 1 S-310 125' - 1" 3" CONC. ON 2" COMPOSITE DECK 6 S-302 SIM. 10 S-302 HSS14x6x3/8 HSS8X6X1/4 LANDING T.O.S. = 118' 9" SIM. 16'-3" 3'-1" 11 7/8" 125' - 1 1/2" T.O. STEEL 124' - 8" T.O. STEEL 1.3 1 A.4 HSS10x6x3/8 HSS10x6x3/8 HSS10x6x3/8 8 S-302 3N 20 GA ROOF DECK S-310 3 Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:45 PM S-401 STAIR TOWER PLANS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-101 S-401 1/4" = 1'-0" 1 STAIR 1 LEVEL 1 FRAMING PLAN S-102 S-401 1/4" = 1'-0" 2 STAIR 1 LEVEL 2 FRAMING PLAN S-103 S-401 1/4" = 1'-0" 3 STAIR 1 LEVEL 3 FRAMING PLAN S-103.5 S-401 1/4" = 1'-0" 4 STAIR 1 ROOF FRAMING PLAN S-102 S-401 1/4" = 1'-0" 5 STAIR 2 LEVEL 2 FRAMING PLAN S-101 S-401 1/4" = 1'-0" 6 STAIR 2 LEVEL 1 FRAMING PLAN S-103 S-401 1/4" = 1'-0" 7 STAIR 2 LEVEL 3 FRAMING PLAN S-103.5 S-401 1/4" = 1'-0" 8 STAIR 2 ROOF FRAMING PLAN PL TO HSS 3/16 L4 TO PL 3 SIDES 3/16 HSS TO L2 3 SIDES 3/16 L2 TO COL HSS TO HSS HSS TO HSS 3/16 L4 TO HSS 2"2" 6" 2"2" 1 1/2" 3" 1 1/2" L7X4X3/8 LLH 3/16 1 - 12 L7 TO HSS HSS TO COL 1/4 HSS TO HSS PL 3/8"X6"X0'-8 1/4" EA. SIDE OF HSS 3/16 PL TO HSS 3 SIDES 3/16 PL TO C12 B.O. LEDGE RE: ARCH T.O. C12 RE: ARCH C12X20.7 RE: ARCH HSS5X5X3/8 ALIGH TO BOTTOM OF BRICK LEDGE . PL 3/4"X6"X1'-2" W/ (4) 3/4"Ø THREDED RODS WELDED TO EMBED PL EMBED PL 3/4"X6"X1'-2" W/ (4) 3/4"Ø HAS CENTERED ON A 3" GAGE W/ 6" MIN EMBEDMENT BENT PL 1/2"X11"X4" LLH 3/16 1 - 12 LTO HSS B.O. LEDGE RE: ARCH HSS6X6X3/8 ALIGH TO BOTTOM OF BRICK LEDGE 6" x 16 GA. STUDS @ 16" O.C. ATTACH TO STEEL W/ SIMPSON RCKW5.5 L3X3X5/16X CONT. Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:44 PM S-310 FRAMING DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-401 S-310 3/4" = 1'-0" 1 SECTION AT STORE FRONT S-401 S-310 3/4" = 1'-0" 2 SECTION AT CANOPY S-401 S-310 3/4" = 1'-0" 3 BEAM TO COLUMN CONNECTION S-102 S-310 3/8" = 1'-0" 4 SECTION AT ENTRY CANOPY S-102 S-310 3/4" = 1'-0" 5 STEEL FRAME AT STORE FRONT 3" WASH 3 1/2" 4 1/2" 3" TOPPING 1'-6" 6" PRECAST SPANDREL ~ RE: ARCH. FOR PROFILE AND REVEALS PANEL HEIGHT (MIN.) 6'-8" SPANDREL TOOLED JOINT ~ RE: DTL. B, STD. JOINT SEALANT DETAILS W.W.F. ~ TYP. 9" 1'-1" 1'-4" CHORD REINF. ~ RE: PLAN OR DETAILS ~ RE: ARCH. DRAFT 6" DAP BARS REFERENCE ELEVATION ~ SEE PLANS 4'-2" ROOF DECK 1 1/2" 20 GA. T.O. SLAB RE: PLAN RETAIL SPACE BELOW CONNECTION PER 8/S-302 6" x 16 GA. STUDS @ 16" O.C. ATTACH TO STEEL W/ SIMPSON RCKW5.5 1'-0" 2" 2'-0" 3" TOPPING 1'-8" STAIR OPNG. STAIR & HANDRAIL, RE: ARCH. 2'-6" 1'-0" DAP TEES CMU WALL RE: ARCH FOR LOCATION SEE GENERAL NOTES FOR REQUIRMENTS STAIR LANDING 2" DECK 3" CMU WALL RE: ARCH FOR LOCATION SEE GENERAL NOTES FOR REQUIRMENTS 1'-2" 1'-0" 1'-6" 3" TOPPING 1'-8" EMBED PL BY P/C MFR. @ 24" O.C. MAX DESIGN FOR 2.5 KIP FACTORED VERTICAL REACTION CONCRETE SLAB ON METAL DECK ~RE: PLAN L3X3X3/8XCONT. PRECAST SPANDREL PANEL SPANDREL CONNECTION AT PRECAST SHEAR WALL BY P/C MFR. PRECAST SHEAR WALL RE: PLAN JOINT 3/4" 1" JOINT PRECAST WALL 5" 5" CORBEL BELOW ~ RE: 8/S3.02-P T.O. STEEL RE: PLAN T.O. PRECAST RE: PLAN P/C WALL OR SPANDREL METAL DECK ~ RE: PLAN RE: GENERAL NOTES FOR CONN. DESIGN REQUIREMENTS STEEL BEAM ~ RE: PLAN EMBED PLATE BY P/C MFR. T.O. STEEL RE: PLAN T.O. PRECAST RE: ARCH P/C WALL OR SPANDREL METAL DECK ~ RE: PLAN FOR SIZE AND DIRECTION L4x4x3/8xCONT. EMBED PLATE BY PRECAST MFR. AT 24" O.C. MAX. ~ DESIGN FOR 1 KIP FACTORED VERTICAL REACTION AND 1 KIP FACTORED HORIZONTAL REACTION 1/4 3" WELD PER PLAN NOTES 2" CONC. SLAB-ON-GRADE ~ RE: PLAN (2) L3x3x1/4x0'-6" W/ (4) 1/2"Ø KWIK BOLT TZ W/ 3 1/4" EMBEDMENT, W/ 9" GAGE ELEVATOR DIVIDER BEAM ~ RE: PLAN 3/16 TYP. 1 1/2" 3" 1 1/2" T.O. SLAB RE: PLAN 1" RE: 10/S1.05-P ELEVATOR PIT WALL ~ RE: 10/S1.05-P NOTE: DOWELS NOT SHOWN FOR CLARITY 1'-0" 2" 1'-0" 1'-6" 3" TOPPING 1'-8" STAIR LANDING EMBED PL BY P/C MFR. DESIGN FOR 12KIP FACTORED VERTICAL REACTION AND 12 KIP FACTORED HORIZONTAL REACTION RE: GENERAL NOTES FOR CONNECTION DESIGN EMBED PL BY P/C MFR. DESIGN FOR 7KIP FACTORED VERTICAL REACTION,8 KIP FACTORED HORIZONTAL REACTION AND 4KIP FACTORED TENSION REACTION EQ EQ 1" MIN. HSS TO EMBED 1/4 HSS TO EMBED 3 SIDES 1" MIN. PC COLUMN EMBED PL BY P/C MFR. DESIGN FOR 5KIP FACTORED VERTICAL REACTION,5 KIP FACTORED HORIZONTAL REACTION AND 5KIP FACTORED TENSION REACTION 1" MIN. HSS TO EMBED 1/4 HSS TO EMBED 3 SIDES PC WALL 1" MIN. Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:43 PM S-302 PRECAST GARAGE DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-102 S-302 1 1/2" = 1'-0" 1 DOUBLE TEE CONN. DETAILS S-102 S-302 3/4" = 1'-0" 3 SECTION AT SLAB DEPRESSION S-102 S-302 3/4" = 1'-0" 2 TYPICAL SPANDREL SECTION AT RETAIL S-401 S-302 3/4" = 1'-0" 5 SECTION AT STAIR OPENING S-103 S-302 3/4" = 1'-0" 6 SECTION AT STAIR LANDING S-302 3/4" = 1'-0" 4 PLAN - P/C SPANDREL AND WALL AT P/C SHEAR WALL S-302 3/4" = 1'-0" 7 STEEL BEAM @ P/C WALL OR SPANDREL S-401 S-302 3/4" = 1'-0" 8 ROOF DECK @ P/C WALL S-302 1 1/2" = 1'-0" 9 ELEVATOR DIVIDER BEAM AT CONC. SLAB-ON-GRADE S-401 S-302 3/4" = 1'-0" 10 SECTION AT STAIR LANDING S-401 S-302 3/4" = 1'-0" 11 STEEL CONNECTION AT P/C COLUMN S-401 S-302 3/4" = 1'-0" 12 SECTION AT STAIR LANDING W.W.F. ~ TYP. RE: ARCH 3'-0" 1" CLR. 10" 1'-4" BARS CHORD REINF. ~ RE: PLAN OR DETAILS DRAFT ~ RE: ARCH. TOOLED JOINT ~ DTL. B, STD. JOINT SEALANT DTLS. COL. CORBEL (FULL WIDTH OF COL.) CONNECTION BY P/C MFR. S-301 6 TYP. REFERENCE ELEVATION ~ SEE PLANS 3'-6" 3" TOPPING 3" MIN. 1'-0" 2'-0" TEE T.O. SLAB RE: PLAN FORMED DRIP PRECAST SPANDREL ~ RE: ARCH. FOR PROFILE AND REVEALS HEIGHT (MIN.) 7'-0" SPANDREL TOOLED JOINT ~ RE: DTL. B, STD. JOINT SEALANT DETAILS W.W.F. ~ TYP. RE: ARCH 3'-0" RE: PLAN 1'-4" CHORD REINF. ~ RE: PLAN OR DETAILS DRAFT ~ RE: ARCH. CONNECTION BY P/C MFR. P/T TEE BARS REFERENCE ELEVATION ~ SEE PLANS 1" GAP P/C COLUMN P/C SPANDREL PANEL 1/4 1/2" RET. T & B (MAX.) 3/8" x 6" x 0'-6 EMBED PLATE BY P/C MANUF. L4x4x3/8 x 0'-4 LONG NOTE: P/C MANUF. MAY PROPOSE ALTERNATIVE CONN. DETAIL FOR APPROVAL. CONNECTION MUST ACCOMMODATE THERMAL MOVEMENT OF SPANDREL. NOTE: PAINT ALL PLATES & ANGLES W/ ZING-RICH PAINT AFTER WELDING. PROVIDE SEALANT IN GAP BETWEEN BACK OF SPANDREL AND COLUMN 3'-0" 7" 7" DAP TEES ~ TYP. CONN. TEES TO IT BEAM ON ALTERNATE TEE STEMS TOOLED JOINT W/ SEALANT ~ RE: DTL. A, STANDARD JOINT SEALANT DTLS. #4 x 6'-0 @ 12"O.C. W.W.F. PRECAST INVERTED-T BEAM BEARING PAD P/C TEE T.O. SLAB RE: PLAN 1" WASH 3" TOPPING 1'-6" PAD BRG. 1'-0" 2'-0" CORBEL FULL WIDTH OF COLUMN P/C COLUMN RE: PLAN RE: PLAN REQUIRED AS 3/8" BEARING PAD 2'-0" TEE = 4" OVER IT BEAMS 3" TOPPING PLUS 1" WASH TOOLED JOINT W/ SEALANT ~ RE: DETAIL A OF STD. JT. SEALANT DETAILS. COLUMN TO DIAPHRAGM CONNECTION BY P/C MFR. P/C IT BEAM P/C TEE STRUCTURAL FRAMING COMPONENTS: PRECAST CONCRETE DOUBLE TEE PRECAST CONCRETE INVERTED TEE BEAM PRECAST CONCRETE COLUMN PRECAST CONCRETE SPANDREL PANEL 3" UNIFORM THICKNESS CONCRETE TOPPING TOPPING SLOPED TO FORM "WASH" TOOLED JOINT WITH SEALANT AT JOINTS BETWEEN DOUBLE TEES AND SPANDREL AND WALL PANELS TOOLED JOINT WITH SEALANT AROUND BASE OF ALL COLUMNS SEAL GAPS BETWEEN COLUMNS AND SPANDREL PANELS WITH SEALANT (SIDES AND TOP) JOINT SEALANT NOTES: BASE OR VALLEY IN "WASH" - NO TOOLED JOINT OR SEALANT HERE TOOLED JOINT WITH SEALANT OVER ALL JOINTS BETWEEN PRECAST DOUBLE TEES. CONTINUE JOINT THROUGH "WASH" AND OVER INVERTED TEE BEAM TOOLED JOINTS WITH SEALANT OVER JOINTS BETWEEN DOUBLE TEES AND BEAM FRAMING 1 2 3 4 5 6 7 8 9 10 11 12 6 5 10 7 7 9 6 8 7 1 3 3 10 3 6 2 4" 4" PARKING DECK SIDE RE: ARCHITECTURAL DRAWINGS FOR SLAB EDGE CONDITION AT OPENINGS BETWEEN P/C LIGHT WALLS ERECTION CONNECTION BY P/C MFR. TOOLED JOINT BOTH SIDES OF WALL ~ RE: DETAIL B OF STANDARD JT. SEALANT DETAILS. WALL PANEL CONNECTION BY P/C MFR. P/C TEE 1/4" THICK BEARING PAD ~ TYP. P/C WALL PANEL RE: SCHEDULE OF WALL FORCES FOR P/C WALL LATERAL LOADS RAMP SIDE T.O. SLAB RE: PLAN DIAPHRAGM CHORD REINF. ~ RE: PLAN OR DTLS. LATERAL LOAD CONN. BY P/C MANUF. (FIRE-PROOFED) WELD-ON CORBEL BEARING PAD 2'-0" 3" TOPPING 3" WASH 6 5/16" 3/4" DP. JT. 2" TEE FLANGE 3" TOPPING (MIN.) 1/2" DRAIN DIA. 1/2" JT. AROUND DRAIN 1/4" RECESS FOR DRAIN AS REQ'D CORE DRILL OR BLOCKOUT TEE FLANGE PROVIDE 1-#4 x 4'-0" BAR EA. SIDE OF DRAIN NOTE: LOCATE AREA DRAINS AT LOW POINTS SHOWN ON PLANS PROVIDE BACKER ROD AND JOINT SEALANT AROUND DRAIN 2" FLANGE 3" TOPPING CLOSE JOINT W/ WIRE MESH TO PREVENT CONC. LEAKAGE SEE DETAILS FOR DT JOINT CONN. BY P/C MANUF. SMOOTH TROWEL FINISH FOR 1 1/2" EACH SIDE OF JOINT W.W.F. AT CL OF TOPPING (CONT. THROUGH JOINT) JOINT BETWEEN TEES SHOWN, JOINTS OVER IT BEAMS SIMILAR TEES 3/4" CLR. BETWEEN SEE SPECS. FOR JOINT SEALER FINISHING REQUIREMENTS. 3/4" WIDE JT. 1 1/8" JOINT SEALANT - PREPARE JT. W/ PRIMER PER MANUF. RECOMMENDATIONS. BACKER ROD BOND BREAKER AT BOTTOM OF JOINT 1/4" RADIUS (EACH SIDE OF JOINT) VEE-SHAPED JOINT @ "WASH" 3" MIN. THICKER PRECAST FRAMING JOINT SEALANT - PREPARE JT. W/ PRIMER PER MANUF. RECOMMENDATIONS. 1/4" RADIUS 3/4" WALL PANEL 1/2" JT. ~ SPANDREL OR COLUMN JOINT WIDTH VARIES BACKER ROD BOND BREAKER AT BOT. OF JOINT CLOSE JOINT TO PREVENT CONC. LEAKAGE DETAIL A DETAIL B RB LB IT 12RB24 20LB40-16 26IT20-12 5ST18 ST DT 10DT24 DEPTH WIDTH NOMINAL DEPTH OF SECTION (IN.) SINGLE TEE WIDTH OF SECTION (FT.) NOMINAL DEPTH OF SECTION (IN.) DOUBLE TEE WIDTH OF SECTION (FT.) DEPTH OF SECTION (IN.) INVERTED TEE SHAPE BEAM WIDTH OF SECTION (IN.) DEPTH OF LEDGE (IN) DEPTH OF SECTION (IN.) L-SHAPE BEAM WIDTH OF SECTION (IN.) DEPTH OF LEDGE (IN.) DEPTH OF SECTION (IN.) RECTANGULAR SHAPE BEAM WIDTH OF SECTION (IN.) DEPTH WIDTH WIDTH DEPTH LEDGE WIDTH DEPTH LEDGE . WIDTH DEPTH TEES 2" AT OTHERS 4 3/4" AT PRETOPPED 5' - 0" PRECAST NOMENCLATURE Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:43 PM S-301 PRECAST GARAGE DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-102 S-301 3/4" = 1'-0" 3 TYPICAL SPANDREL SECTION S-102 S-301 3/4" = 1'-0" 5 TYPICAL SPANDREL AT COLUMN SECTION S-102 S-301 3/4" = 1'-0" 4 TYPICAL SPANDREL SECTION S-301 S-301 3" = 1'-0" 6 SPANDREL/COLUMN CONN. DETAIL S-102 S-301 3/4" = 1'-0" 7 SECTION AT IT BEAM S-102 S-301 3/4" = 1'-0" 9 TYPICAL COLUMN DETAIL S-301 1/4" = 1'-0" 2 JOINT SEALANT ISOMETRIC DETAIL S-102 S-301 3/4" = 1'-0" 8 SECTION AT RAMP WALL S-301 3" = 1'-0" 10 TYPICAL AREA DRAIN DETAIL S-102 S-301 3" = 1'-0" 11 STANDARD JOINT SEALANT DETAILS S-301 3/4" = 1'-0" 1 PRECAST NOMENCLATURE REINFORCING T.O. WALL RE: PLAN T.O. SLAB RE: PLAN T.O. WALL RE: PLAN B.O. WALL T.O. PIER RE: PLAN CONT. VOID RE: PLAN T.O. SLAB RE: PLAN #5xCONT. #4x @ 18" O.C. SLAB-ON-GRADE ~ RE: PLAN 2'-0" 2'-0" RE: PLAN #5 HORIZ. @ 12" O.C. #4 TIES. @ 6" O.C. (3) #8 T&B #4 TIES @ 5" O.C. (2) #9 T&B Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:42 PM S-203 FOUNDATION DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-401 S-203 3/4" = 1'-0" 1 TYPICAL STAIR ON GRADE DETAIL S-401 S-203 3/4" = 1'-0" 2 GRADE BEAM SECTION AT STAIR CORE S-401 S-203 1 1/2" = 1'-0" 3 COLUMN BASE AT STAIR TOWER S-101 S-203 3/4" = 1'-0" 4 SECTION AT RETAIL STEM WALL S-401 S-203 3/4" = 1'-0" 5 GRADE BEAM SECTION AT STAIR CORE RE: PLAN RE: PLAN #4x4'-0" LONG @ 18" O.C. #4x @ 18" O.C. SLAB-ON-GRADE ~ RE: PLAN 2'-0" 2'-0" SITE PAVING ~ RE: CIVIL RE: 11/S-201 FOR REINF. 4" CONT. VOID RE: PLAN 3" #5x CONT. T.O. SLAB RE: PLAN T.O. PIER RE: PLAN DRILLED PIER ~ RE: PLAN & SCHEDULE FOR PIER SIZE & REINF. 3'-0" (4)-#5 CONT. EACH FACE SLAB-ON-GRADE ~ RE: PLAN 3/8" EXPANSION JOINT MAT'L P/C SHEAR WALL OR LITE WALL DOWELS PER 5/S-202 AT EXTENDED 2'-2" MIN. INTO TIE BEAM, TERMINATE WITH STANDARD HOOKS (7)-#8 CONT. TOP & BOT. 4'-0" #5 TIES AT 6" O.C. ENSURE FIRST TIE IS WITHIN 3" OF FACE OF PIER 5 S-202 T.O. TIE BEAM RE: PLAN SLAB-ON-GRADE ~ RE: PLAN #5 HORIZ. @ 18" O.C. EACH FACE #5 VERT. @ 12" O.C. T.O. SLAB RE: PLAN T.O. PIER RE: PLAN 3/8" EXPANSION JOINT MATERIAL SHORE WALL PRIOR TO BACKFILLING AND LEAVE IN PLACE UNTIL RAMP SLAB IS IN PLACE DRILLED PIER ~ RE: PLAN AND PIER SCHEDULE FOR PIER SIZE AND REINFORCING POUR DOWN WALL AT PIERS 3- #8 TOP AND BOTTOM DRILLED PIER DOWELS ~ RE: 11/S-201 #5 VERT.@ 16" O.C. RE: PLAN x CONT. 4" VOID T.O. WALL RE: PLAN P/C SHEAR WALL OR LITE WALL T.O. SLAB RE: PLAN T.O. PIER RE: PLAN DRILLED PIER ~ RE: PLAN & SCHEDULE FOR PIER SIZE & REINF. #5 HORIZ. @ 12" O.C. #5 VERT. @ 12" O.C. #5x @ 12" O.C. 4'-8" #6 @ 12" O .C. EA. WAY T&B HOOK ENDS T.O. WALL RE: PLAN SLAB-ON-GRADE ~ RE: PLAN 3/8" EXPANSION JOINT MATERIAL, TYP. RE: ARCH T.O. MATT RE: PLAN T.O. SLAB RE: PLAN #5 @ 12" O .C. SIDE REINFORCING DRILLED PIER BELOW ~RE: PLAN TIE BEAM. REINFORCING NOT SHOWN FOR CLARITY. ~RE: PLAN (6) #9x6'-8" DOWELS WITH STANDARD HOOK. IF DOWELS ARE WET-STABBED INTO PIER, VIBRATE TOP OF OF PIER AFTER DOWELS ARE PLACED. POSITION DOWELS SIMILAR TO WHAT IS SHOWN, ENSURE THE STANDARD HOOKS WILL BE INSIDE THE TIE BEAM ABOVE 4" 8" 1'-0" RE: PLANS TEE SPACING 2'-0" 3" TOPPING SEAL GAP AGAINST CONC. LEAKAGE WALL REINF. ~ RE: DETAILS #5 x 6'-0" @ 12" O.C. SLOPE ~ RE: PLANS 5" S.O.G. #5 CONT. #4 x @ 12" O.C. 2'-6 #6 @ 12" O.C. #6 @ 3" O.C. BASE TO 3'-0" #6 @ 9" O.C. 3'-0" TO 6'-0" #6 @ 12" REMAINDER EXPANSION JOINT MATERIAL SLAB ON GRADE ~RE: PLAN T.O. SLAB RE: PLAN (4) #6 DOWELS INTO EA. PIER BRACE WALL UNTIL SLAB CONCRETE IS FULLY CURED T.O. DRILLED PIER RE: PLAN T.O. SLAB RE: PLAN T.O. PIER CAP RE: PLAN T.O. SLAB RE: PLAN STEM WALL BEYOND P/C COLUMN PIER CAP RE: SCHEDULE SHEET S-101 CONC. PILASTER REINFORCE W/ (4) #8 VERT. AND #4 TIES @ 12" O.C. (3) ADDITIONAL TIES AT TOP DOWELS TO MATCH COL. REINF. T.O. WALL RE: PLAN 6 S-202 3" 3" 3" 3" #5 x @ 9" O.C. #6 x @ 6" O.C. EACH WAY CONCRETE PIER CAP T.O. PIER CAP RE: PLAN T.O. SLAB RE: PLAN PIER CAP RE: SCHEDULE SHEET S-101 RE: 11/S-202 FOR REINFORCING CONC. PILASTER REINFORCE W/ (4) #8 VERT. DOWELS HOOKED INTO PIER CAP AND #4 TIES @ 12" O.C. SITE PAVING ~ RE: CIVIL T.O. PILASTER RE: PLAN P/C SPANDREL NOTCH SPANDREL OVER CAP Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:41 PM S-202 FOUNDATION DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-101 S-202 3/4" = 1'-0" 1 PILASTER DETAIL @ RETAIL S-101 S-202 1/2" = 1'-0" 2 SECTION AT ELECTRICAL ROOM S-202 3/4" = 1'-0" 4 GRADE BEAM/FOUNDATION WALL STEP DETAIL S-202 S-202 3/4" = 1'-0" 6 CONCRETE GRADE BEAM @ CONCRETE PILASTER S-101 S-202 3/4" = 1'-0" 7 SECTION AT ENTRY S-101 S-202 3/4" = 1'-0" 8 P/C SHEAR WALL/LITE WALL @ CONC. TIE BEAM S-411 S-202 3/4" = 1'-0" 9 SECTION AT RAMP FOUNDATION WALL S-401 S-202 3/4" = 1'-0" 10 ELEVATOR PIT AT TIE BEAM S-202 S-202 3/4" = 1'-0" 5 DRILLED PIER AT TIE BEAM S-101 S-202 3/4" = 1'-0" 3 RAMP S.O.G. / P/C DECK TRANSITION DETAIL S-101 S-202 3/4" = 1'-0" 11 PILASTER AT RETAIL S-101 S-202 3/4" = 1'-0" 12 PILASTER AT ENTRY 3" THREE ADD'L TIES AT TOP OF DRILLED PIERS 1'-6" TYP. 1'-6" 1'-6" TYP. 3" 1'-6" TYP. 2" RE: SCHED. FOR REINF. REQUIRED DO NOT SPLICE VERTICAL REINF. WITHIN THE TOP 30 FEET OF PIER LENGTH. SPACE TIES AT 12" O.C. FOR LENGTH OF LAP SPLICE. RE: SCHEDULE FOR CLASS B LAP SPLICE LENGTH C1 D2 B1 A1 30" 36" LATERAL LATERAL 10 FT. 10 FT. 12 FT. 10 FT. D1 36" 12 FT. (6) #5 (6) #6 (6) #6 (6) #7 (6) #9 (10) #12 #4 @ 9" O.C. #4 @ 9" O.C. #4 @ 10" O.C. #4 @ 12" O.C. #4 @ 14" O.C. #4 @ 18" O.C. TYPICAL DEPRESSED SLAB OR SLAB STEP SUBBASE AND SUBGRADE RE: TYPICAL S.O.G JOINT DETAIL VAPOR BARRIER (IF REQ'D.) ~RE: SPECIFICATIONS AND ARCH. DRAWINGS. PROTECT BARRIER FROM PUNCTURE TYPICAL THICKENED SLAB TYPICAL UNDER NON LOAD BEARING MASONRY WALLS NOT ON GRADE BEAM 1-#5 CONT. EACH SIDE OF WALL VAPOR BARRIER (IF REQ'D.) ~RE: SPECIFICATIONS AND ARCH. DRAWINGS. PROTECT BARRIER FROM PUNCTURE SLAB REINF. RE: PLAN VERTICAL REINF. PER GENERAL NOTES OR DTLS., # 5 AT 48" O.C. (MIN) 1' - 0" 6" 'T' 'H' # 5 AT 12" O.C. 3'-0 SLAB RIENF. RE: PLAN NOTE: PROVIDE CONTROL JOINT IN CONCRETE 5'-0 FROM SLAB STEP WHEN 'H' IS 4" OR GREATER. # 5 CONT. NOTE: PROVIDE SLAB STEP REINF. BARS ONLY AT LOCATIONS WHERE 'H' IS 4" OR GREATER MASONRY WALL ('T'=THICKNESS) 4" 'T' 4" 9" MIN. # 5 DOWELS x SPACING TO MATCH VERT. REINF. 2'-6 6" TYPICAL SLAB CONTROL JOINT SEE PLANS AND SPECIFICATIONS FOR LOCATIONS OF CONTROL JOINTS 1/8" T/4 SUBBASE ~ RE: PLAN NOTES AND SPECIFICTIONS PREPARED SUBGRADE OR UNDISTURBED SOIL. SEE BUILDING PAD OVER-EXCAVATION DETAIL VAPOR BARRIER (IF REQ'D.) ~RE: SPECIFICATIONS AND ARCH. DRAWINGS. PROTECT BARRIER FROM PUNCTURE SLAB REINF., CONT. THROUGH JOINT CONTROL JOINT ~ RE: SPECIFICATIONS FOR CONSTRUCTION OF JOINT SLAB THICKNESS 'T' RE: PLAN TYPICAL SLAB CONSTRUCTION JOINT LOCATE UNDER PARTITION WHEN POSSIBLE SEE SPECS. FOR POUR LIMITATIONS SUBBASE ~ RE: SPECS. 1" x2" CONT. KEY, ~RE: SPECS VAPOR BARRIER (IF REQ'D.) ~RE: SPECIFICATIONS AND ARCH. DRAWINGS. PROTECT BARRIER FROM PUNCTURE STOP SLAB REINF. AT JOINT FILL WITH JOINT SEALANT 'T' APPLY BOND BREAKER FULL LENGTH AND DEPTH OF THE JOINT EXTERIOR INTERIOR GRID 1/2" EXPANSION JOINT MATERIAL VARIES LENGTH 6" MIN. ~ TYP. SLAB CONSTRUCTION OR CONTROL JOINTS ~ RE: 3/S-301 CONCRETE CAST SEPARATELY FROM SLAB-ON-GRADE CORNER GRID GRID GRID CONCRETE COLUMN 5" SLAB 3/8" EXP. JT. MATERIAL DRILLED PIER SPANDREL SUPPORT, RE: PLAN EXTERIOR OF BUILDING INTERIOR OF BUILDING 3'-0" (MIN.) RE: PLAN SLAB THICKNESS, DETAILS AND NOTES LAYER OF GRANULAR AND SUBBASE MAT'L. RE: S.O.G. PER GEOTECHNICAL REPORT AND SPECIFICATIONS EXCAVATION AND BACKFILL BELOW LAYER OF SUBBASE UNDISTURBED, NATURAL SOILS, INSPECTED AND APPROVED BY BASE OF EXCAVATION GEOTECHNICAL ENGINEER LAY BACK EXCAVATION PER OSHA REQUIREMENTS RE: SPECIFICATIONS IMPORTED, STRUCTURAL FILL OR RECONDITIONED ON-SITE SOILS, RE: SPECIFICATIONS FOR MATERIAL REQUIREMENTS 9" 1'-1" RE: ARCH 4" VOID P/C SPANDRAL 3/8" EXP. JT. MATERIAL TO PIER 1'-5 1/2" DRILLED PIER SPANDREL SUPPORT, RE: PLAN P/C COL. ~RE: PLAN ANCHOR BOLTS BY P/C MFR. ~PLACED BY CONTRACTOR 3/8" EXP. JT. MATERIAL RE: PLAN RE: PLAN RE: PLAN T.O. SLAB RE: PLAN GROUT 2" T.O. DRILLED PIER RE: PLAN GROUT CONNECTION POCKETS SOLID DRILLED PIER ~RE: PLAN AND SCHEDULE FOR SIZE AND REINF. 9" 1" JT. 1'-0" 2'-2" 1'-8" 1'-0" RE: ARCH VOID 4" DRILLED PIER P/C SPANDREL P/C COLUMN NOTCH SPANDREL OVER CAP PIER CAP RE: SCHEDULE SHEET S-101 RE: 11/S-202 FOR REINFORCING 4" VOID T.O. PIER CAP RE: PLAN T.O. SLAB/CURB RE: PLAN T.O. DRILLED PIER RE: PLAN 3/8" EXP. JT. MAT. 6" x 16 GA. STUDS @ 16" O.C. SITE PAVING OR SIDEWALK BRICK VENEER RE: ARCH. RE: PLAN RE: PLAN RE: PLAN 1 OR 7 POUR GRADE BEAM DOWN TO TOP OF PIER DRILLED PIER, RE: PLAN T.O. LEDGE RE: PLAN T.O. SLAB/CURB RE: PLAN B.O. GRADE BEAM RE: PLAN T.O. DRILLED PIER RE: PLAN (2) #9 T&B #4 TIES @ 5" O.C. NO SLAB AT SIM. #4x @ 12" O.C. 1'-7" 1'-7" #5x CONT. #5 SKIN REINF. @ 12" O.C. (4) #6 DOWELS 6"x16 GA. STUDS @ 16" O.C. STOREFRONT RE: ARCH. SITE CONC. RE: PLAN RE: PALN RE: PLAN SEE DTL. 11/S-201 FOR ADDL. INFO. BRICK VENEER RE: ARCH. T.O. LEDGE RE: PLAN T.O. SLAB/CURB RE: PLAN B.O. GRADE BEAM RE: PLAN T.O. DRILLED PIER RE: PLAN Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:40 PM S-201 FOUNDATION DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-201 3/4" = 1'-0" 5 DRILLED PIER DETAIL S-201 3/4" = 1'-0" 2 TYPICAL SLAB ON GRADE DETAILS S-201 3/4" = 1'-0" 3 TYPICAL SLAB ON GRADE JOINT DETAILS S-201 3/4" = 1'-0" 4 TYPICAL SLAB-ON-GRADE BLOCKOUTS AT COLUMNS S-201 3/4" = 1'-0" 6 BUILDING PAD OVEREXCAVATION DETAIL S-101 S-201 3/4" = 1'-0" 9 TYPICAL P/C SPANDREL DETAIL S-101 S-201 3/4" = 1'-0" 8 P/C COLUMN TO DRILLED PIER DETAIL S-101 S-201 3/4" = 1'-0" 10 PIER CAP & COLUMN DETAIL S-101 S-201 3/4" = 1'-0" 11 FOUNDATION DETAIL @ RETAIL S-101 S-201 3/4" = 1'-0" 12 FOUNDATION DETAIL @ RETAIL HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS4x4x3/8 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 HSS6x6x1/2 W10x22 HSS10x6x3/8 HSS10x6x3/8 135' - 2" T.O.S. TYP. 1 S-411 A.4 S-401 4 S-401 8 1'-0" HSS10x6x3/8 Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:39 PM S-103.5 LEVEL 3.5 FRAMING PLAN 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-103.5 3/32" = 1'-0" 1 Level 3.5 FRAMING PLAN = 40'-0" 4 SPCS. @ 10'-0" 1" GAP 3 S-301 1'-1" 9" 1'-10" 16'-7" 8'-0" 7'-9" 7'-9" 3 S-301 6 S-302 7 S-301 7 S-301 3 S-301 4 S-301 5 S-301 4 S-301 3 S-301 5 S-301 8" 8" POUR STRIP 1'-0" 18'-0" 8" 6'-0" HIGH P/C SPANDREL 1'-10" 13'-6 1/2" 25'-5 1/2" 1'-1" 9" 16 TEES @ 10'-0" O.C. = 160'-0" 7'-1 1/2" 7'-1 1/2" 9'-7" 8'-1" 8'-1" 1" GAP 8'-3 1/2" 8'-3 1/2" 8'-0" 7'-9" 7'-9" OPEN TO BELOW 10'-0 1/8" 9'-11 7/8" 10'-0" 10'-0" 10'-0 1/8" 0" 10'-9" 9'-9" 9'-9" 9'-9" 1" GAP 4" 4" 4'-0" 6'-0" 4'-0" 6'-0" 2'-0" 4" 4" 2'-1" 9" 1'-1" 1'-1" 9" 9" 9" 9" 1'-1" 1'-10" 1'-6" 2'-6" 5'-0" 6" TEE STEMS 3 S-411 DT24 TEES (TYP.) 20LB30-12 26IT34-12 26IT34-12 26IT34-12 11 S-301 11 S-301 1 S-302 TYP TYP TYP 16" x 16" CIP PILASTER TYP. 32 PLACES 1'-10" 39'-0" 40'-0" 40'-0" 40'-0" 40'-0" 39'-0" 1'-10" 241'-8" HSS14x6x3/8 HSS14x6x3/8 W10x22 HSS14x6x3/8 HSS14x6x3/8 HSS14x6x3/8 1 S-411 26IT34-12 A.4 S-401 3 S-401 7 HSS6x6x3/8 HSS6x6x3/8 HSS6x4x1/4 120' - 11 1/2" T.O.S. TYP. 8 S-301 8 S-301 1.5B 20 GA. ROOF DECK HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 NOTES: 1. TOP OF SLAB ELEVATION NOTED THUS: ON PLAN (BELOW CONCRETE WASH). SLOPE FLOOR FRAMING UNIFORMILY BETWEEN POINTS OF UNEQUAL ELEVATION. 2. FLOOR FRAMING SHALL BE NORMAL WEIGHT CONCRETE TOPPING OVER 24" DEEP PRECAST DOUBLE TEES. TOPPING THICKNESS SHALL BE A UNIFORM 3" FOLLOWING TEE CAMER. SEE DETAILS FOR ADDITIONAL CONCRETE TOPPING REQUIRED AT WASHES AT EDGES OF SLAB AND OVER INVERTED TEE BEAMS. REINFORCE TOPPING WITH 6x6 - W2.9xW2.9 WELDED WIRE FABRIC. 3. SEE SHEET S-102 FOR ADDITIONAL PLAN NOTES. DESIGN LOADS: DEAD 1. 3" UNIFORM THICK. CONCRETE TOPPING. 38.0 PSF LOADS: 2. 24" DEEP BY 10'-0" WIDE NW DOUBLE TEES. 50.0 PSF 3. MISCELLANEOUS (SPRINKLERS, LIGHTS): 5.0 PSF TOTAL: 93.0 PSF LIVE 1. PARKING LIVE LOAD: 40.0 PSF (RED.) LOADS: 2. SNOW LOAD: 30.0 PSF (NR) XXX'-X" DRIFTING SNOW LOAD SCHEDULE A EXTERIOR 37.1 PSF SPANDREL B 27.9 PSF WALL PANEL 6'-3" C 28.8 PSF WALL PANEL D 57.0 PSF EXTERIOR SPANDREL 12'-10" E EXTERIOR 41.6 PSF SPANDREL 16'-7" 6'-6" 1. DRIFT LOADS SHOWN ABOVE DO NOT INCLUDE THE BALANCED SNOW LOAD. ADD 30.0 PSF UNIFORM SNOW LOAD TO DRIFT LOADS. NOTES: 11'-4" Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:36 PM S-103 LEVEL 3 FRAMING PLAN 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-411 S-103 3/32" = 1'-0" 1 Level 3 FRAMING PLAN 19'-2" 8'-10" 1'-11" 26IT34-12 4" 4" 6'-0" 4'-0" 6'-0" 4'-0 7/8" RAMP DOWN RAMP UP 4" 4" 9" 1'-1" 16'-7" 8'-0" 7'-9" 7'-9" 16 TEES @ 10'-0" O.C. = 160'-0" 7'-1 1/2" 7'-1 1/2" 9'-7" 8'-1" 8'-1" 16 TEES @ 10'-0" O.C. = 160'-0" TO TOP OF RAMP 26IT34-12 1'-1" 8" 9" 1'-1" 1'-10" 1'-10" 18'-4" 4'-2" 18'-4" 3 S-302 3 S-301 3 S-301 3 S-301 3 S-301 3 S-301 7 S-301 5 S-301 7 S-301 5 S-301 5 S-301 5 S-301 7 S-301 7 S-301 4 S-301 4 S-301 4 S-301 4 S-301 8 S-301 8 S-301 8 S-301 2 S-302 10'-0" 10'-0" 10'-0" 10'-0" 4" 10'-5" 9'-9" 9'-9" 9'-9" 1" GAP 1" GAP 2 S-411 DEPRESS SLAB SLAB FOR W.P. MEMBRANE & TOPPING SLAB 26IT34-12 / 14 26IT34-12 / 14 26IT34-12 / 14 2'-8 5/8" 18'-10" 9'-5" DT24 TEES DT18 TEES DT24 TEES 26IT34-12 26IT34-12 DT18 TEES DT24 TEES DT18 TEES DT24 TEES DT18 TEES 20LB30-12 9 S-301 9 S-301 11 S-301 11 S-301 1 S-302 TYP TYP TYP 1'-10" 39'-0" 40'-0" 40'-0" 40'-0" 40'-0" 39'-0" 1'-10" 241'-8" HSS14x6x3/8 HSS14x6x3/8 W10x22 HSS14x6x3/8 W8X10 HSS14x6x3/8 1 S-411 S-401 5 S-401 2 S-102 5 A.4 9'-9" 26IT30-12 / 14 26IT30-12 / 14 26IT30-12 / 14 7'-0 5/8" 14'-2 1/8" HSS8x6x3/8 HSS8x6x3/8 HSS8x6x3/8 112' - 0 3/8" T.O. STEEL 5 S-310 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 115' - 4" 113' - 2" 113' - 2" 115' - 4" 113' - 2" 113' - 2" 115' - 4" 113' - 2" 113' - 2" 115' - 4" T.O. STEEL T.O. STEEL T.O. STEEL T.O. STEEL T.O. STEEL T.O. STEEL T.O. STEEL T.O. STEEL T.O. STEEL T.O. STEEL 2 S-302 5 S-310 3 S-302 10'-2 7/8" 4'-8 3/4" 5'-3" 4'-8 3/4" 5'-3" 10'-8 3/4" HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 HSS6x4x1/4 115' - 0" T.O. STEEL TYP. HSS KICKER PRECAST (DOUBLE TEE) GARAGE FLOOR FRAMING PLAN NOTES NOTES: 1. TOP OF SLAB ELEVATION NOTED THUS: ON PLAN. (BELOW CONCRETE WASH. SLOPE FLOOR FRAMING UNIFORMLY BETWEEN POINTS OF UNEQUAL ELEVATION. 2. FLOOR FRAMING SHALL BE NORMAL WEIGHT CONCRETE TOPPING OVER PRECAST DOUBLE TEES. SEE PLAN FOR DEPTH OF DOUBLE TEE FRAMING. TOPPING THICKNESS SHALL BE A UNIFORM 3" FOLLOWING TEE CAMBER. SEE DETAILS FOR ADDITIOANL CONCRETE TOPPING REQUIRED AT WASHES AT EDGES OF SLAB AND OVER INVERTED TEE BEAMS. REINFORCED TOPPING WITH 6x6-W2.9xW2.9 WELDED WIRE FABRIC. 3. PRECAST COLUMNS SHALL BE 24". 4. PROVIDE 2-#6 CONTINUOUS REINFORCING AROUND PERIMETER OF FLOOR IN CAST-IN-PLACE TOPPING. 5. SEE SHEETS SX.X AND SX.X FOR SHEARWALL DESIGN FORCES, PLANS AND ELEVATIONS. 6. PROVIDE EMBED PLATES TO SUPPORT STAIR FRAMING AS REQUIRED. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 7. INDICATES 4" THICK (MIN.) NORMAL WEIGHT CONCRETE PAD UNDER MECHANICAL EQUIPMENT. REINFORCE PAD WITH #4 BARS AT 12" O.C.EACH WAY AT CENTER OF PAD THICKNESS. 8. DESIGN WEIGHT, SIZE AND LOCATION OF MECHANICAL EQUIPMENT IS SHOWN ON PLAN. CONTRACTOR SHALL VERIFY PURCHASED EQUIPMENT AGAINST IS SHOWN AND IMMEDIATELY REPORT ANY DIFFERENCES TO THE ARCHITECT AND STRUCTURAL ENGINEER. XXX'-X" DESIGN LOADS: DEAD 1. 3" UNIFORM THICKN. CONCRETE TOPPING: 38.0 PSF LOADS: 2. 24" DEEP BY 10'-0" WIDE NW DOUBLE TEES: 50.0 PSF 3. MISCELANEOUS (SPRINKLERS, LIGHTS): 5.0 PSF TOTAL: 93.0 PSF LIVE 1. PARKING LIVE LOAD: 40.0 PSF (RED) LOADS: HSS12x6x1/2 C8x13.7 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 HSS8x2x1/4 C8x13.7 C8x13.7 1'-4 1/4" 1'-3 7/8" HSS18x6x5/8 HIGH LOW 112' - 6" 110' - 0" T.O. STEEL HIGH T.O. STEEL LOW 4 S-310 110' - 0" T.O. STEEL Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:30 PM S-102 LEVEL 2 FRAMING PLAN 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-411 S-102 3/32" = 1'-0" 1 Level 2 FRAMING PLAN S-102 S-102 3/16" = 1'-0" 5 Level 2 - Callout 3 4" S.O.G. 8" PRE-CAST WALLS CENTERED ON GRID 14" GRADE BEAM BELOW P/C LITE WALLS 12" FDN. WALL 10 S-201 12 S-201 1 S-202 8 S-201 1'-0" 9" 1'-10" 1'-8" 9" 20'-10" 9 S-201 10 S-201 1'-10" 9" 1'-10" 9" 9 S-201 10 S-201 9" 2'-9" 9" 1'-10" 1'-8" 9" 20'-0" 20'-0" 20'-0" 19'-6" 20'-0" 20'-0" 20'-0" 20'-6" 18'-6 3/4" A1 A1 A1 5" S.O.G. D1 D1 A1 C1 D1 C1 C1 C1 B1 A1 A1 A1 A1 A1 D2 D2 D2 D2 B1 D1 D1 A1 D1 D1 D1 D1 C1 B1 B1 B2 B2 B2 B2 B2 B2 B2 B2 A1 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 2 S-411 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B1 A1 A1 A1 ( 99' - 10" ) ( 98' - 11" ) ( 98' - 11" ) ( 98' - 11" ) ( 99' - 1" ) ( 98' - 2" ) ( 97' - 7" ) ( 96' - 10" ) ( 96' - 2" ) ( 96' - 2" ) ( 96' - 2" ) ( 96' - 6" ) ( 96' - 2" ) ( 96' - 2" ) ( 96' - 2" ) ( 101' - 5" ) ( 101' - 7" ) ( 101' - 5" ) ( 96' - 6" ) ( 97' - 2" ) ( 98' - 6" ) A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 ( 97' - 6" ) ( 97' - 6" ) ( 97' - 11" ) ( 98' - 8" ) ( 99' - 4" ) ( 100' - 5" ) ( 100' - 10" ) ( 100' - 10" ) ( 99' - 5 1/2" ) ( 99' - 10" ) ( 98' - 4" ) ( 99' - 6" ) ( 97' - 6" ) ( 98' - 10" ) ( 97' - 2" ) ( 97' - 2" ) ( 97' - 10" ) ( 98' - 6" ) D2 D2 D2 D2 D2 D2 D2 D2 ( 95' - 8" ) ( 95' - 8" ) ( 95' - 8" ) ( 95' - 8" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) A1 A1 A1 ( 98' - 10" ) ( 98' - 6" ) ( 98' - 2" ) 8" 4" . RAMP . RAMP PC1 PC1 PC3 PC2 PC4 PC2 PC4 PC4 PC10 PC1 PC5 PC5 PC1 PC1 PC1 PC1 PC1 PC7 PC4 PC1 PC1 PC4 PC7 PC1 PC2 PC2 PC2 PC2 PC1 PC1 PC1 PC1 PC1 PC2 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 B2 PC1 101' - 3" 102' - 2" 102' - 0" 101' - 8" ( 96' - 6" ) ( 96' - 6" ) 99' - 0" 99' - 0" 99' - 0" 99' - 0" 99' - 0" 99' - 0" 99' - 0" 99' - 0" 99' - 8" 99' - 8" 99' - 0" 99' - 0" 100' - 4" 100' - 5" 101' - 0" 101' - 0" 101' - 0" 101' - 0" 101' - 11" 102' - 8" 102' - 8" 102' - 8" 102' - 8" 102' - 6" 102' - 6" 101' - 11" 95' - 0" ( 95' - 8" ) ( 95' - 8" ) ( 95' - 8" ) ( 95' - 8" ) ( 95' - 8" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 98' - 4" ) ( 95' - 8" ) ( 95' - 8" ) ( 95' - 8" ) ( 95' - 8" ) ( 95' - 8" ) 99' - 8" 100' - 6" PC9 PC9 3 S-202 11 BETWEEN S-201 WINDOWS AT WINDOWS ( 99' - 10" ) A1 PC1 102' - 5" A1 ( 100' - 1" ) PC9 HSS10x6x5/8 HSS6x6x3/8 HSS6x6x1/2 102' - 7" 1 S-411 HSS6x6x3/8 HSS6x6x3/8 2 S-202 18'-8" A1 ( 94' - 6" ) A1 A1 ( 94' - 6" ) ( 94' - 6" ) A1 ( 94' - 6" ) HSS6x6x3/8 S-401 1 S-401 6 A1 A1 A1 A1 A.4 102' - 5" 103' - 8 7/8" 103' - 6" 103' - 6" 102' - 3 1/2" 102' - 3 1/2" 103' - 0 1/4" 103' - 0 1/4" 103' - 8 7/8" 103' - 5 1/4" 103' - 5 1/4" 103' - 3" 103' - 3" 100' - 0" 100' - 0" 100' - 0" 100' - 0" 99' - 6" 100' - 0" 100' - 0" 100' - 0" 103' - 2" ( 98' - 8" ) ( 98' - 8" ) ( 98' - 8" ) ( 98' - 8" ) 99' - 0" RAMP . 7 S-202 . RAMP S-101 2 11 S-201 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 AT DOOR WAYS 102' - 0" ( 99' - 6" ) A1 ( 98' - 6" ) 101' - 0" PC2 9'-3 7/8" 10'-1 3/4" 10'-3 7/8" 10'-1 3/4" 10'-3 7/8" 11'-1 3/4" 104' - 9" T.O. WALL 97' - 6" B.O. WALL B.O. WALL 99' - 8 3/4" 97' - 10" STEP B.O. WALL 98' - 8" B.O. WALL STEP B.O. WALL STEP B.O. WALL 99' - 5" B.O. WALL ( 99' - 4" ) 100' - 0" B.O. WALL TYPICAL P/C COL. TO BE 24"X24" U.N.O 16"X16" P/C COL. ON CIP PILASTER 16"X16" P/C COL. ON CIP PILASTER 16"X16" P/C COL. ON CIP PILASTER 16"X16" P/C COL. 16"X16" P/C COL. 16"X16" P/C COL. 16"X16" P/C COL. COL. CL 4'-7 1/8" A1 ( 100' - 10" ) 20'-10" 4 S-203 104' - 1 3/4" B2 95' - 0" A1 ( 99' - 0" ) A1 ( 99' - 0" ) A1 ( 99' - 0" ) A1 ( 99' - 0" ) 3'-3 7/8" 8" 8" 3'-3 7/8" 8" 2'-3 1/4" 16'-2 3/8" 102' - 10" T.O.WALL 3'-7 7/8" 24'-7 1/8" 6'-6" 24'-1 1/8" 20'-10" 20'-10" 100' - 0" 8" 4" 1'-8" 1'-8" 1'-8" 1'-8" 1'-8" 1'-8" 1'-8" 1'-8" 2'-0" 2'-0" 1'-8" 9 7/8" S-101 3 ( 98' - 6" ) 100' - 8" 100' - 8" 100' - 4" 101' - 0" 1'-7 3/4" 101' - 0" T.O. GRADE BEAM ( 98' - 10" ) 100' - 4" T.O. GRADE BEAM 98' - 2" STEP T.O. GRADE BEAM B.O. GRADE BEAM B.O. GRADE BEAM STEP B.O. GRADE BEAM 100' - 4" T.O. GRADE BEAM 99' - 8" T.O. GRADE BEAM STEP T.O. GRADE BEAM ( 97' - 10" ) 97' - 6" B.O. GRADE BEAM STEP B.O. GRADE BEAM 99' - 8" T.O. GRADE BEAM 99' - 0" T.O. GRADE BEAM STEP T.O. GRADE BEAM 1'-8" 11 S-201 SIM. HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 1 S-202 SIM. 1'-10" 6" 6" 10" 1'-0" 1'-0" 10" 9 S-201 9 S-201 1'-6" 9'-0" 9'-0" 1'-6" 1'-6" 9'-0" 9'-0" 1'-6" 1'-5 1/2" 1'-6" 9'-0" 9'-0" 1'-6" 3'-2 1/2" 9 1/2" 1'-6" 9'-0" 9'-0" 1'-6" ( 98' - 4" ) ( 98' - 4" ) ( 95' - 8" ) ( 95' - 8" ) 1'-5 1/2" 6 1/2" 3'-5 1/2" 6 1/2" 3'-5 1/2" 1'-2 1/2" 6 1/2" 3'-5 1/2" 1'-5 1/2" 8 S-202 8 S-202 8 S-202 8 S-202 101' - 8" T.O. TIE BEAM 101' - 8" T.O. TIE BEAM 99' - 0" T.O. TIE BEAM 99' - 0" T.O. TIE BEAM 4 S-203 4" 4" 4" 1'-0" 5 1/4" 4" 1'-0" 11 S-202 4 S-203 SIM. 1'-9" 1'-10 5/8" 12 S-202 12 S-202 9 S-201 10 S-201 10 S-201 100' - 5" 101' - 7" ( 96' - 2" ) ( 96' - 2" ) ( 99' - 6" ) 99' - 6" ( 99' - 2" ) ( 99' - 1" ) ( 99' - 8" ) ( 99' - 8" ) ( 99' - 10" ) ( 99' - 10" ) ( 99' - 10" ) ( 98' - 6" ) ( 98' - 2" ) ( 97' - 10" ) ( 98' - 9" ) ( 98' - 0" ) ( 97' - 2" ) 99' - 0" 99' - 8" ( 98' - 11" ) A1 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 HSS6x6x3/8 NOTES: XXX'-X 1. TOP OF SLAB ELEVATION = 100'-0 (4973.5 USGS), UNLESS NOTED THUS: ON PLAN. SLAB SHALL SLOPE UNIFORMLY BETWEEN POINTS OF UNEQUAL ELEVATION. 2. GARAGE SLAB ON GRADE SHALL BE 5" THICK NORMAL WEIGHT CONCRETE WITH FIBOURS REINFORCING OVER 4"THICK LAYER OF GRANULAR MATERIAL, RE: SPECIFICATIONS. REINFORCE SLAB. 3. RETAIL SLAB ON GRADE SHALL BE 4" THICK NORMAL WEIGHT CONCRETE WITH FIBOURS REINFORCING CONSTRUCTED OVER A VAPOR BARRIER. PLACE THE VAPOR BARRIER OVER A 4" THICK LAYER OF GRANULAR MATERIAL, RE: SPECIFICATIONS. 4. REFER TO DETAIL 6/S-201 AND EARTHWORK SPECIFICATIONS FOR OVEREXCAVATION REQUIREMENTS. 5. RE: DETAIL 3/S-201 FOR SLAB ON GRADE JOINTING REQUIREMENTS. PROVIDE CONTROL JOINTS AT A MAXIMUM SPACING OF 10'-0" O.C. UNLESS NOTED OTHERWISE ON PLAN. PROVIDE THICKENED SLAB BENEATH ALL CMU WALLS AND AT STAIR CONNECTION WHERE NO FOUNDATION ISSHOWN. RE: 2/S-201 6. RE: DETAIL 4/S-201 FOR SLAB ON GRADE JOINTING REQUIREMENTS AT COLUMNS. 7. SEE FOUNDATION LEGEND ON THIS SHEET FOR PIER, COLUMN, AND PILASTERS, AND PIER CAP NOMENCLATURE. 8. DRILLED PIERS TO BE CENTERED ON GRID LINES, OR UNDER COLUMNS, FOUNDATION WALLS, OR GRADE BEAMS, UNLESS DIMENSIONED OTHERWISE ON PLAN. 9. PRECAST COLUMNS SHALL BE 24" SQUARE UNLESS NOTED OTHERWISE ON PLAN 10. COLUMNS SHALL BE CENTERED ON GRIDS UNLESS DIMENSIONED OTHERWISE ON PLAN. 11. RE: S-411 FOR SHEARWALL DIMENSIONS, ELEVATIONS, AND DESIGN FORCES. 12. RE: CONCRETE REINFORCING SPLICE SCHEDULE ON SHEET S-001. 13. PROVIDE 4" THICK CONCRETE HOUSEKEEPING PADS UNDER ALL FLOOR MOUNTED MECHANICAL AND ELECTRICAL EQUIPMENT. RE: ARCHITECTURAL AND MEP DRAWINGS FOR SIZE AND LOCATION. REINFORCE PAD WITH #3 BARS AT 12" O.C. EACH WAY. 14. DENOTES SLAB STEP ~ RE: 1/S-202. AX PCX ( XXX'-X" ) XX'-X" TOP OF DRILLED PIER ELEVATION TOP OF PIER CAP PIER MARK ~ RE: DRILLED PIER SCHEDULE ON S-101 PIER CAP MARK ~ RE: PIER CAP SCHEDULE THIS PIER CAP SHEET DRILLED PIER P/C COLUMN FOUNDATION LEGEND 4 C D E F 5 7" 9" 2'-6 3/8" 1'-0 7/8" 9'-0" 2'-11 5/8" 4'-0 3/8" 2'-0" 1'-10 3/4" 2'-0 7/8" 2'-0" 4'-0 3/8" 2'-11 5/8" 9'-0" 1'-10 3/4" 2'-0 7/8" 2'-0" 4'-0 3/8" 2'-11 5/8" 9'-0" 2'-10 3/4" 1'-0 1/8" 6" 6" 101' - 0" T.O. LEDGE STEP T.O. GRADE BEAM 101' - 9" 99' - 2" B.O. GRADE BEAM STEP B.O. GRADE BEAM ( 99' - 10" ) 20'-9" STEP T.O. GRADE BEAM 101' - 0" T.O. LEDGE 101' - 9" 20'-9" STEP B.O. GRADE BEAM ( 100' - 2" ) B.O. GRADE BEAM 101' - 0" B.O. GRADE BEAM T.O. GRADE BEAM T.O. GRADE BEAM T.O. LEDGE 101' - 8" T.O. LEDGE 101' - 11" T.O. GRADE BEAM STEP T.O. BEAM STEP T.O. BEAM STEP T.O. BEAM 101' - 8" T.O. LEDGE 101' - 11" T.O. GRADE BEAM 101' - 8" T.O. LEDGE 102' - 0" T.O. LEDGE 102' - 6" T.O. GRADE BEAM 102' - 0" T.O. LEDGE 102' - 6" T.O. GRADE BEAM 102' - 0" T.O.SLAB 102' - 7" T.O.SLAB 102' - 5" T.O.SLAB 103' - 2" 7" 9" 2 1/8" 8" 6" 2 1/8" 7" 9" 2 1/8" 7" 9" 2 1/8" 10" 6" 2 1/8" 6" 6" 2 1/8" STEP T.O. BEAM STEP T.O. BEAM STEP T.O. BEAM STEP T.O. BEAM STEP T.O. BEAM STEP T.O. BEAM STEP T.O. BEAM STEP T.O. BEAM STEP T.O. BEAM 1 C D E F 7'-3 5/8" 10" 2'-2 1/4" 1'-8 5/8" T.O. LEDGE 101' - 9" T.O. CURB 9" 19'-3" 9" 19'-3" 20'-0" 7" 6" 1'-7 7/8" 6'-9 5/8" 6" 101' - 9" T.O. CURB 101' - 0" 100' - 8" STEP T.O. LEDGE 101' - 0" T.O. LEDGE T.O. LEDGE ( 99' - 2" ) ( 98' - 10" ) 1'-8 5/8" 2'-3" B.O. GRADE BEAM STEP B.O. GRADE BEAM 101' - 0" T.O. CURB B.O. GRADE BEAM STEP T.O. CURB 1'-8 5/8" 2'-3" 15'-0" 100' - 4" STEP T.O. LEDGE 100' - 8" T.O. LEDGE T.O. LEDGE 98' - 10" 98' - 6" B.O. GRADE BEAM STEP B.O. GRADE BEAM B.O. GRADE BEAM 100' - 4" 101' - 0" T.O. CURB T.O. LEDGE 8'-1 5/8" 9" 7" 6'-9 5/8" 6" 8" 1'-3" 2" 2" 2" 2" Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:26 PM S-101 FOUNDATION PLAN 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE S-411 S-101 3/32" = 1'-0" 1 LEVEL 1 FRAMING PLAN PIER CAP SCHEDULE TYPE WIDTH LENGTH Comments PC1 3' - 10" 3' - 10" PC2 2' - 4" 2' - 4" PC3 4' - 0" 4' - 0" PC4 3' - 0" 3' - 0" PC5 3' - 0" 3' - 1" PC7 3' - 8" 3' - 8" PC9 2' - 1" 2' - 1" PC10 5' - 5" 3' - 10" S-101 S-101 1/8" = 1'-0" 2 FIREHOUSE GRADEBEAM PLAN S-101 S-101 1/8" = 1'-0" 3 JEFFERSON GRADEBEAM PLAN framing, and joist framing.) 1705.3 Concrete construction - Provide inspections per Table 1705.3. Post-installed anchors in concrete: 2. Verify hole diameter and depth, method of drilling using appropriate bit, and hole preparation as recommended by anchor manufacturer. 1705.4 Masonry construction - Provide inspection and verification of masonry construction as follows: 1705.6 Soils - Provide inspections per Table 1705.6. 1705.8 Cast-In-Place Deep Foundations - Provide inspections per Table 1705.8. 1705.13 Sprayed fire-resistant materials - Inspect sprayed fire-resistant materials as follows: 1. Inspect surface preparation for compliance with the approved fire-resistance design and the approved manufacturer's written instructions. 1705.14 Mastic and intumescent fire-resistant coatings - Inspect mastic and intumescent fire-resistant coatings in accordance with AWCI 12-B. - - - - - - - - - - - - - - - - x - x x x x x x x x x x x - x 4. Measure average thickness per ASTM E605 and Section 1704.12.4. 1. Inspect welds. 1. Verify anchor description including product name, diameter and length. 3. Verify installation locations including anchor distance to edge of concrete and anchor spacing. 2. Verify minimum ambient temperature before and after application. 3. Verify ventilation of area during and after application. 5. Verify density of material for conformance with the approved fire-resistant design and ASTM E605. 6. Test cohesive/adhesive bond strength per IBC Section 1704.12.6. 2. Inspection of cold formed framing for compliance with approved construction documents and shop drawings: a. Details such as bracing and stiffening b. Member sizes and locations. c. Application of details at each connection. SCHEDULE OF SPECIAL INSPECTIONS FOR STANDARD BUILDINGS - x 4. Inspection of anchors post-installed in hardened concrete - x ACI 318: 3.8.6, 8.1.3, 21.2.8 1909.1 ACI 318: 8.1.3, 21.2.8 STANDARD BUILDING SPECIAL INSPECTION REQUIREMENTS (per IBC Section 1704.2): This Statement of Special Inspections is submitted in accordance with the requirements of the 2012 International Building Code (IBC) Sections 1704 and 1705. Special Inspections and Structural Observations applicable to this project: • Special Inspections for Standard Buildings (per IBC 1704.2) • Special Inspections for Seismic Resistance (per IBC 1705.11) • Special Inspections for Wind Resistance (per IBC 1705.10) • Structural Observations for Seismic Resistance (per IBC 1704.5.1) • Structural Observations for Wind Resistance (per IBC 1704.5.2) This Statement of Special Inspections is intended to apply only to items within the scope of work of the Structural Engineer. See Statement of Special Inspections prepared by the design professional in responsible charge for additional special inspection requirements applicable to other disciplines. The following Schedules of Special Inspections summarize the Special Inspections and Tests required. Special Inspectors shall refer to the approved plans and specifications for detailed special inspection requirements. Any additional tests and inspections required by the approved plans and specifications shall also be performed. Special Inspections and Testing shall be performed in accordance with the approved plans and specifications, this statement and IBC Sections 1704 and 1705. The owner shall retain and directly pay for the special inspections and testing as required by IBC section 1704.2. Interim Special Inspection Reports shall be submitted to the Building Official and the Registered Design Professional in Responsible Charge in accordance with IBC Section 1704.2.4. A Final Report of Special Inspections shall be submitted to the Building Official and the Registered Design Professional in Responsible Charge in accordance with IBC Section 1704.2.4. This Statement of Special Inspections has been developed with the understanding that the Building Official will: • Review and approve the qualifications of the Special Inspectors who will perform the inspections. • Monitor special inspection activities on the job site to assure that the Special Inspectors are qualified and are performing their duties as called for in this Statement of Special Inspections. • Review submitted inspection reports. • Perform inspections as required by IBC Section 110 and the local building code. Structural Observations, when required, will be performed by a registered professional engineer from S. A. Miro, Inc. At the conclusion of the work included in the permit, the structural observer shall submit to the Building Official a written statement that the site visits have been made and identify any reported deficiencies that, to the best of the structural observer's knowledge, have not been resolved. Structural Observation does not include or waive the responsibility for the Special Inspections included in this Statement of Special Inspections or the inspections required by IBC Section 110. Provide inspections required in the Schedule of Special Inspections for Standard Buildings. STATEMENT OF SPECIAL INSPECTIONS STRUCTURAL GENERAL NOTES REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED 1. Structures with empirically designed masonry, glass unit masonry or masonry veneer designed in accordance with ACI 530-11, Chapters 5, 6 or 7 in Risk Category I, II or III shall be inspected and verified per Table 1.19.1 2. Structures with glass unit masonry or masonry veneer designed in accordance - - with ACI 530-11, Chapters 6 or 7 in Risk Category IV shall be inspected and verified per Table 1.19.2 3. Structures with masonry designed in accordance with chapters other than 5, 6 or 7 - - in ACI 530-11 in Risk Category I, II or III shall be inspected and verified per Table 1.19.2 4. Structures with masonry designed in accordance with chapters other than 5, 6 or 7 - - in ACI 530-11 in Risk Category IV shall be inspected and verified per Table 1.19.3 INSPECTION REQUIREMENT REFERENCE Material identification procedures Review of material test reports and certifications Section 6.1 of Code of Standard Practice MINIMUM REQUIREMENTS FOR INSPECTION OF STRUCTURAL STEEL BUILDINGS AISC 360, N5.2 Quality Control (QC) Inspector Qualifications AISC 360, N4.1 Quality Assurance (QA) Inspector Qualifications AISC 360, N4.2 NDT Personnel Qualifications AISC 360, N4.3 Inspections performed in fabricator's shop: Shop welding inspections performed prior, during, and after welding Nondestructive testing of shop welded joints Shop bolting inspections performed prior, during, and after bolting Shop cut and finished surfaces Shop heating for straightening, cambering and curving Tolerances for shop fabrications AISC 360, N5.4 AISC 360, N5.5 AISC 360, N5.6 AISC 360, N2, M2 AISC 360, N2, M2.1 Section 6 of Code of Standard Practice Inspections performed in field: Field welding inspections performed prior, during, and after welding Nondestructive testing of field welded joints Field bolting inspections performed prior, during, and after bolting Placement and fastening of composite steel deck Installation of steel headed stud anchors Field cut surfaces Field heating for straightening Tolerances for field erection Inspection of erected steel for conformance to project documents AISC 360, N5.4 AISC 360, N5.5 AISC 360, N5.6 AISC 360, N6 AISC 360, N6 AISC 360, N2, M2.2 AISC 360, N2, M2.1 Section 7.13 of Code of Standard Practice AISC N.7 Submittal of inspection and testing reports AISC 360, N5.2 Submittal of certificate of compliance AISC 360, N7 1. Material verification of cold-formed steel deck: a. Identification markings to conform to ASTM standards specified in the approved construction documents. b. Manufacturer's certified test reports. 2. Inspection of welding: a. Cold-formed steel deck: 1) Floor and roof deck welds. TABLE 1705.2.2 REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION OTHER THAN STRUCTURAL STEEL - x VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARD Applicable ASTM material standards - x - x AWS D1.3 x x b. Cold-formed steel framing including joists and studs: 1) Floor and roof framing welds. - x AWS D1.3 c. Reinforcing steel: 1) Verification of weldability of reinforcing steel other than ASTM A 706. - x AWS D1.4 ACI 318: Section 3.5.2 2) Reinforcing steel resisting flexural and axial forced in intermediate and special moment frames, and boundary elements of special structural walls of concrete and shear reinforcing. - 3) Shear reinforcement. - 4) Other reinforcing steel. - x - - 1. Observe drilling operations and maintain complete and accurate records for each element. 2. Verify placement locations and plumbness, confirm element diameters, bell diameters (if applicable), lengths, embedment into bedrock (if applicable) and adequate end-bearing strata capacity. Record concrete or grout volumes. 3. For concrete elements, perform additional inspections in accordance with Section 1705.3. TABLE 1705.6 REQUIRED VERIFICATION AND INSPECTION OF SOILS PERIODICALLY DURING TASK LISTED 1. Verify materials below shallow foundations are adequate to achieve the design bearing capacity. 2. Verify excavations are extended to proper depth and have reached proper material. 3. Perform classification and testing of compacted fill materials. 4. Verify use of proper materials, densities and lift thicknesses during placement and compaction of compacted fill. 5. Prior to placement of compacted fill, observe subgrade and verify that site has been prepared properly. VERIFICATION AND INSPECTION TASK CONTINUOUS DURING TASK LISTED - x - x - x x - - x TABLE 1705.8 REQUIRED VERIFICATION AND INSPECTION OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS VERIFICATION AND INSPECTION TASK CONTINUOUS DURING TASK LISTED PERIODICALLY DURING TASK LISTED x - x - - - Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:23 PM S-003 STRUCTURAL GENERAL NOTES 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE B. DIFFERENCES OR CONFLICTS BETWEEN THE DRAWINGS AND MECHANICAL AND ELECTRICAL REQUIREMENTS SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. C. PENETRATIONS: THE GENERAL CONTRACTOR SHALL SUBMIT COORDINATED AND DIMENSIONED DRAWINGS SHOWING ALL MECHANICAL, PLUMBING AND ELECTRICAL PENETRATIONS THROUGH CONCRETE FLOOR AND ROOF SLABS FOR REVIEW AND APPROVAL AT LEAST THREE WEEKS PRIOR TO STARTING THE WORK. A. THE FLOOR AND ROOF FRAMING IS DESIGNED TO SUPPORT THE MECHANICAL AND ELECTRICAL EQUIPMENT SHOWN ON PLANS. DIFFERENCES IN ACTUAL EQUIPMENT LOCATION, SIZE OR WEIGHT MAY REQUIRE REDESIGN OF THE FRAMING AT THE EXPENSE OF THE CONTRACTOR. B. PROVIDE 4" HIGH CONCRETE PADS UNDER FLOOR MOUNTED MEP EQUIPMENT. REINFORCE PADS WITH #4 BARS AT 12" O.C. UNLESS NOTED OTHERWISE. C. PROVIDE CONCRETE PADS UNDER ROOF TOP EQUIPMENT ONLY AS SHOWN ON THE STRUCTURAL DRAWINGS. A. SLEEVES AND CORE DRILLING THROUGH CONCRETE SLABS ON METAL DECK ARE PERMITTED SUBJECT TO THE FOLLOWING RESTRICTIONS: a. PENETRATIONS SHALL NOT EXCEED 6" IN DIAMETER b. EDGE OF PENETRATION SHALL BE A MINIMUM OF 2" CLEAR FROM EDGE OF BEAM FLANGE. c. MULTIPLE PENETRATIONS SHALL BE SPACED A MINIMUM OF 1 CORE DIAMETER APART USING THE LARGER PENETRATION DIAMETER. d. LOCATE SLAB REINFORCING PRIOR TO MAKING PENETRATION AND ADJUST PENETRATION LOCATION TO AVOID REINFORCING. IF PENETRATION LOCATION CANNOT BE ADJUSTED, OBTAIN ENGINEER'S APPROVAL PRIOR TO MAKING PENETRATION. e. A MAXIMUM OF THREE PENETRATIONS WITH MINIMUM SPACING MAY BE GROUPED WITHOUT ENGINEER'S APPROVAL. NO MORE THAN FOUR PENETRATIONS ARE ALLOWED BETWEEN ADJACENT FLOOR BEAMS UNLESS APPROVED BY ENGINEER. A. CORE DRILLING THROUGH CONCRETE SLABS IS PERMITTED SUBJECT TO THE FOLLOWING RESTRICTIONS: a. PENETRATIONS SHALL NOT EXCEED 6" IN DIAMETER b. EDGE OF PENETRATION SHALL BE A MINIMUM OF 2" CLEAR FROM EDGE OF DOUBLE TEE LEG c. MULTIPLE PENETRATIONS SHALL BE SPACED A MINIMUM OF 1 CORE DIAMETER APART USING THE LARGER PENETRATION DIAMETER. d. SUBMIT DIMENSIONED PLANS SHOWING CORE DRILLED OPENINGS FOR REVIEW AND APPROVAL WHEN THREE OR MORE PENETRATIONS ARE GROUPED TOGETHER WITHIN AN AREA MEASURING 5'-0 SQUARE. A. ELECTRICAL CONDUIT IS ALLOWED IN CONCRETE SLABS ON METAL DECK SUBJECT TO THE FOLLOWING RESTRICTIONS: a. CONDUIT O.D. SHALL NOT EXCEED 1". MINIMUM CLEAR DISTANCE BETWEEN CONDUITS IS 2". b. NO MORE THAN THREE CONDUITS MAY BE BUNDLED IN ONE GROUP. BUNDLED CONDUITS SHALL HAVE AT LEAST 12" CLEAR BETWEEN GROUPS. c. CONDUIT MAY NOT CROSS WITHIN FLOOR SLAB THICKNESS. d. CONDUIT SHALL REST DIRECTLY ON METAL DECK AND WILL BE SECURELY FASTENED DOWN. A. ELECTRICAL CONDUIT IS ALLOWED IN CONCRETE TOPPING OVER DOUBLE TEES SUBJECT TO THE FOLLOWING RESTRICTIONS: a. CONDUIT O.D. SHALL NOT EXCEED 1". MINIMUM CLEAR DISTANCE BETWEEN CONDUITS IS 2". b. NO MORE THAN THREE CONDUITS MAY BE BUNDLED IN ONE GROUP. BUNDLED CONDUITS SHALL HAVE AT LEAST 12" CLEAR BETWEEN GROUPS. c. CONDUIT MAY NOT CROSS WITHIN TOPPING THICKNESS. d. CONDUIT SHALL REST DIRECTLY ON TEE FLANGE AND WILL BE SECURELY FASTENED DOWN. e. NO CONDUIT IS ALLOWED IN CONCRETE TOPPING IN GARAGE CONSTRUCTION UNLESS SHOWN OTHERWISE ON THE DRAWINGS. A. SUPPORT OF MECHANICAL, PLUMBING AND ELECTRICAL ITEMS SUSPENDED FROM CONCRETE FLOOR AND ROOF SLABS IS THE RESPONSIBILITY OF THE CONTRACTOR INCLUDING DETERMINING THE NUMBER AND POSITION OF FASTENERS. THE FOLLOWING FASTENERS ARE APPROVED FOR USE IN CONCRETE: a. POWDER ACTUATED FASTENERS: HILTI UNIVERSAL KNURLED SHANK FASTENER (X-U) WITH 1-1/4" EMBEDMENT. IN POST-TENSIONED DECKS, USE 3/4" MAXIMUM EMBEDMENT. b. DRILLED ANCHORS: HILTI DROP-IN CONCRETE EXPANSION ANCHOR (X-GN) WITH 1-1/2" EMBEDMENT. IN POST-TENSIONED DECKS, USE POWERS 3/8" MINI DROP-IN ANCHOR WITH EMBEDMENT NO MORE THAN 3/4". c. EMBEDDED ANCHORS: USE HILTI HCI-WF OR HIS-MD AS APPROPRIATE OR UNISTRUT P3300 SERIES CONCRETE INSERT. d. DO NOT SUSPEND LOADS GREATER THAN 1,000 LBS. FROM CONCRETE DECK. PROVIDE SUPPORT FRAMING BETWEEN MAIN STRUCTURAL FRAMING. e. THE CONTRACTOR MAY SUBMIT MANUFACTURER'S DATA FOR ALTERNATE FASTENERS FOR REVIEW AND APPROVAL. A. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW OF MEP ITEMS EMBEDDED IN FLOOR AND ROOF SLABS PRIOR TO PLACEMENT OF CONCRETE. NOTIFICATION SHALL OCCUR AT LEAST 48 HOURS PRIOR TO POUR. B. OBSERVATION BY ARCHITECT OR ENGINEER DOES NOT RELIEVE CONTRACTOR FROM MEETING REQUIREMENTS LISTED IN PRECEDING PARAGRAPHS. 30-INSTRUCTIONS AND COORDINATION EXPLANATION OF SECTION DIAGRAM USED (PLAN SHEET) EXPLANATION OF SECTION DIAGRAM USED (DETAIL SHEET) 1. COORDINATION: 2. SUBSTITUTIONS: 3. QUALITY CONTROL: 5. INSTRUCTIONS TO CONTRACTOR: 6. DRAWING NOMENCLATURE: 4. ENGINEERING DESIGN PERFORMED BY CONTRACTOR: A. ANY DIFFERENCES BETWEEN THE ARCHITECTURAL AND STRUCTURAL DRAWINGS SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. B. CONFLICTS WITHIN THE STRUCTURAL DRAWINGS OR BETWEEN THE STRUCTURAL DRAWINGS, GENERAL NOTES AND/OR SPECIFICATIONS SHALL BE REPORTED TO THE STRUCTURAL ENGINEER FOR RESOLUTION BEFORE PROCEEDING WITH MODIFICATIONS OR ADJUSTMENT. C. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE MECHANICAL AND ELECTRICAL EQUIPMENT PURCHASED WITH INFORMATION SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING, BUT NOT LIMITED TO, EQUIPMENT LOCATION, SIZE, WEIGHT, OPENINGS AND SUPPORT REQUIREMENTS. REPORT DIFFERENCES TO THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH THE WORK. D. EXISTING CONDITIONS: THE STRUCTURAL DRAWINGS HAVE BEEN PREPARED USING AVAILABLE INFORMATION OF EXISTING CONDITIONS. NO ATTEMPT HAS BEEN MADE TO VERIFY EXISTING CONDITIONS AGAINST INFORMATION RECEIVED FROM THE CLIENT OR OTHER SOURCES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPARE THE EXISTING CONDITIONS TO THE INFORMATION SHOWN ON THE DRAWINGS AND NOTIFY THE ARCHITECT OF ANY DIFFERENCES BEFORE PROCEEDING WITH THE WORK. A. SUBSTITUTIONS ARE NOT ALLOWED WITHOUT APPROVAL FROM THE ARCHITECT AND STRUCTURAL ENGINEER. REQUEST FOR SUBSTITUTION MUST BE ACCOMPANIED BY PROPER INFORMATION NECESSARY TO EVALUATE THE SUBSTITUTION AND COMPENSATION FROM THE CONTRACTOR MAY BE REQUIRED TO CONDUCT THE EVALUATION PROCESS. A. THE CONTRACTOR SHALL MAINTAIN A LOG OF DISCREPANCIES NOTED BY THE INDEPENDENT TESTING AGENCY FOR THE DURATION OF THE PROJECT. EACH ITEM IN THE LOG SHALL BE REFERENCED BY AN ITEM NUMBER WITH A DESCRIPTION OF THE DISCREPANCY, THE DATE THE DISCREPANCY WAS NOTED, A DESCRIPTION OF THE CORRECTIVE ACTION TAKEN AND THE DATE OF THE CORRECTIVE ACTION. B. A LETTER OF ENGINEER'S STATEMENT USED TO OBTAIN A CERTIFICATE OF OCCUPANCY CANNOT BE ISSUED UNTIL ALL ITEMS NOTED IN THE DISCREPANCY LOG ARE ADDRESSED TO THE ENGINEER'S SATISFACTION. C. PRECONSTRUCTION MEETINGS: THE GENERAL CONTRACTOR SHALL CONDUCT THE FOLLOWING PRECONSTRUCTION MEETINGS IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS: a. DRILLED PIER INSTALLATION b. CAST-IN-PLACE CONCRETE CONSTRUCTION c. LOAD-BEARING, PRECAST CONCRETE CONSTRUCTION EACH MEETING SHALL BE ATTENDED BY THE ARCHITECT AND/OR STRUCTURAL ENGINEER, THE GENERAL CONTRACTOR, THE INDEPENDENT TESTING AGENCY AND REPRESENTATIVES OF THE AFFECTED SUBCONTRACTORS. A. TEMPORARY BRACING: DURING ERECTION OF THE BUILDING, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND PLACEMENT OF TEMPORARY BRACING TO WITHSTAND ALL LOADS TO WHICH THE STRUCTURE MAY BE SUBJECTED, INCLUDING LATERAL LOADS AND STOCKPILES OF MATERIAL AND EQUIPMENT. BRACING SHALL BE LEFT IN PLACE AS LONG AS NECESSARY FOR SAFETY AND UNTIL ALL STRUCTURAL FRAMING AND FLOOR AND ROOF DIAPHRAGMS ARE IN PLACE WITH CONNECTIONS COMPLETED. B. STORAGE: THE CONTRACTOR SHALL NOT STOCKPILE MATERIAL OR EQUIPMENT IN A MANNER THAT EXCEEDS THE LOAD CAPACITY OF THE STRUCTURE OR CAUSES DAMAGE OR EXCESSIVE DEFLECTION OF STRUCTURAL ELEMENTS. C. BACKFILL OF FOUNDATION WALLS: DO NOT PLACE BACKFILL AGAINST FOUNDATION WALLS UNTIL TOP AND BOTTOM OF WALLS ARE ADEQUATELY BRACED. ADEQUATE BRACING INCLUDES THE FOLLOWING: a. SLAB ON GRADE THAT HAS REACHED 75% OF ITS DESIGN STRENGTH INCLUDING COMPLETION OF DELAY OR POUR STRIPS. b. ELEVATED CAST-IN-PLACE CONCRETE FLOOR CONSTRUCTION THAT HAS REACHED 75% OF ITS DESIGN STRENGTH INCLUDING COMPLETION OF DELAY OR POUR STRIPS c. ELEVATED PRECAST FLOOR CONSTRUCTION WHERE CONNECTIONS BETWEEN PRECAST AND WALL ARE COMPLETED AND CONCRETE TOPPING IS IN PLACE AND HAS REACHED 75% OF ITS DESIGN STRENGTH. d. ELEVATED STRUCTURAL STEEL-FRAMED FLOOR CONSTRUCTION WHERE FRAMING CONNECTIONS TO THE WALL ARE COMPLETE AND CONCRETE TOPPING IS IN PLACE AND HAS REACHED 75% OF ITS DESIGN STRENGTH. A. EXPLANATION OF SECTION CUT CALL-OUT: SECTION IDENTIFICATION STRUCTURAL SHEET WHERE SECTION IS DRAWN STRUCTURAL SHEET WHERE SECTION IDENTIFICATION SECTION IS FIRST CUT STRUCTURAL SHEET WHERE SECTION IS DRAWN A. THE CONTRACTOR OR RESPONSIBLE SUBCONTRACTOR SHALL HAVE APROFESSIONAL ENGINEER LICENSED IN THE PROJECT JURISDICTION PERFORM ENGINEERING DESIGN OF THE FOLLOWING BUILDING COMPONENTS INCLUDING, BUT NOT LIMITED TO, LOAD DETERMINATION, COMPONENT ANALYSIS AND DESIGN AND CONNECTION ANALYSIS AND DESIGN: a. PREFABRICATED STEEL STAIRS b. EXTERIOR WALL ENCLOSURES c. SUPPORT OF MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT THE ENGINEERING DESIGN SHALL CONSIDER THE EFFECTS OF SUPPORTING THE BUILDING COMPONENTS FROM THE PRIMARY STRUCTURE AND INCLUDE ALL BRACING NECESSARY TO MAINTAIN STABILITY OF THE AFFECTED STRUCTURAL FRAMING. B. CORRECTIVE MEASURES DUE TO ERRORS OR DEFECTS IN CONSTRUCTION: THE CONTRACTOR SHALL SUBMIT PLANS, DETAILS AND CALCULATIONS FOR PROPOSED CORRECTIVE MEASURES FOR REVIEW BY ARCHITECT AND STRUCTURAL ENGINEER. WHEN REQUIRED, THE SUBMITTED DOCUMENTS SHALL BE SEALED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE PROJECT JURISDICTION. ABBREVIATIONS A.B. @ -ANCHOR BOLT(S) -AT -ADDITIONAL -ANCHOR -APPROXIMATE -ARCHITECT OR ARCHITECTURAL DOCUMENTS ADDN'L ANCH. APPROX. ARCH. AVG BLDG. BLK. BM. BOD BOT. OR B. -AVERAGE -BUILDING -BLOCK -BEAM -BOTTOM OF DECK -BEARING -BOTTOM BRG. BTWN. BW CANT. C-C CEIL. OR CLG. C.I.P. C.J. -BETWEEN -BUTT WELD -CANTILEVER -CENTER TO CENTER -CEILING -CAST IN PLACE -CONTROL JOINT OR CONSTRUCTION JOINT CL OR CLR C.M.U. CL CLR. COL. CONC. CONN. CONSTR. CONT. CONTR. CTR. OR CNTR. CTR'D. DBL. DEPR DET OR DTL DIA. DIAG. DIM. DN. DP DWG. DWL. EA. E.F. E.J. E. OR ELECT'L -CLEAR -CONCRETE MASONRY UNIT -CENTER LINE -CLEAR -COLUMN -CONCRETE -CONNECTION -CONSTRUCTION -CONTINUE OR CONTINUOUS -CONTRACTOR -CENTER -CENTERED -DOUBLE -DEPRESSION -DETAIL -DIAMETER -DIAGONAL -DIMENSION -DOWN -DEEP OR DEPTH -DRAWING(S) -DOWEL -EACH -EACH FACE -EXPANSION JOINT -ELECTRICAL -ELEVATION -ENGINEER -EQUAL -EACH SIDE -EACH WAY -EAST-WEST -EXCAVATE -EXISTING -EXPANSION -EXTERIOR -FABRICATION -FOUNDATION -FAR FACE OR FINISHED FLOOR EL. OR ELEV. ENGR EQ. ES EW E-W EXC EXIST. EXP. EXT. FAB FDN F.F. FIN. FLG. FLR. FS FT. FTG. GA. GALV. GC OR GEN CONTR GLU-LAM GR OR GRD H.A.S. HORIZ.-HOR. HT. I.D. I.F. IN INCL INFO INT JT. -FINISH -FLANGE -FLOOR -FAR SIDE -FOOT-FEET -FOOTING -GAGE OR GAUGE -GALVANIZED -GENERAL CONTRACTOR -GLUE LAMINATED -GRADE -HEADED ANCHOR STUD -HORIZONTAL -HEIGHT -INSIDE DIAMETER -INSIDE FACE -INCH -INCLUDE -INFORMATION -INTERIOR -JOINT K -KIP = 1000 LBS. LB OR # LG. L.L.H. L.L.V. LOC. LT.-LGT. LWC MACH MAS MATL. MAX. M.B. MECH. MEMB. MEZZ. MFR. OR MFRR. MID. MIN. MISC NF NO. NS N-S N.T.S. -POUND(S) -LONG -LONG LEG HORIZONTAL -LONG LEG VERTICAL -LOCATION -LIGHT -LIGHT WEIGHT CONCRETE -MACHINE -MASONRY -MATERIAL -MAXIMUM -MACHINE BOLT -MECHANICAL -MEMBRANE -MEZZANINE -MANUFACTURER -MIDDLE -MINIMUM -MISCELLANEOUS -NEAR FACE -NUMBER -NEAR SIDE -NORTH-SOUTH -NOT TO SCALE -ON CENTER -OUTSIDE DIAMETER -OUTSIDE FACE -OVERHANG -OPENING -OPPOSITE -OPPOSITE HAND O.C. OR O/C O.D. O.F. O.H. OPNG. OPP OPP HD P.C. OR P/C PCF PEN PL PERP. P.L. PLF PLYWD PP PRELIM PSI R. OR RAD. R RE: REINF. REQ'D. SCHED. SECT SHTHG SH OR SHT SIM. SLV -PRECAST -POUNDS PER CUBIC FOOT -PENETRATION -PLATE -PERPENDICULAR -PROPERTY LINE -POUNDS PER LINEAL FOOT -PLYWOOD -PANEL POINT OR PARTIAL PENETRATION -PRELIMINARY -POUNDS PER SQUARE INCH -RADIUS -RISER (STAIR) -REFERENCE -REINFORCED OR -REQUIRED -SCHEDULE -SECTION -SHEATHING -SHEET -SIMILAR -SLEEVE OR SHORT LEG VERTICAL SLH -SHORT LEG HORIZONTAL SOG SP OR SPCS SPCG SPEC. SQ. STD. STIFF. STL. STRUCT. SYMM. T. T AND B T AND G THK THK'ND TOC TOF TOPG TOS TR TYP. U.N.O. VERT. W/ W/O WD W.P. WT.-WGT. W.W.F. OR W.W.M. X-BRACE -SLAB ON GRADE -SPACES -SPACING -SPECIFICATION -SQUARE -STANDARD -STIFFENER -STEEL -STRUCTURE OR -SYMMETRICAL -TOP OR TREAD (STAIR) -TOP AND BOTTOM -TONGUE AND GROOVE -THICK OR THICKNESS -THICKENED -TOP OF CONCRETE -TOP OF FOOTING -TOPPING -TOP OF STEEL, TOP OF SLAB -TRUSS -TYPICAL -UNLESS NOTED OTHERWISE -VERTICAL -WITH -WITHOUT -WOOD -WORKING POINT -WEIGHT -WELDED WIRE FABRIC -CROSS BRACING MTL. -METAL STRUCTURAL REINFORCING 5. COLD-FORMED METAL FRAMING: A. COLD-FORMED METAL FRAMING REFERENCED IN THIS SECTION PERTAINS TO FRAMING DESCRIBED IN SPECIFICATION DIVISION 05 40 00 ONLY. B. REFERENCE STANDARDS: COLD-FORMED METAL FRAMING SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF COLD- FORMED STEEL STRUCTURAL MEMBERS". C. FABRICATION: COLD-FORMED METAL FRAMING PRODUCTS SHALL BE MANUFACTURED BY A CURRENT MEMBER OF THE STEEL STUD MANUFACTURERS ASSOCIATION (SSMA). D. SHEET STEEL USED IN THE FABRICATION OF COLD-FORMED FRAMING PRODUCTS SHALL CONFORM TO ASTM A1003, STRUCTURAL GRADE, TYPE H OR ASTM A653 AND SHALL BE ZINC COATED IN ACCORDANCE WITH ASTM A924, G60. MINIMUM YIELD STRENGTH SHALL BE 50 KSI OR 33 KSI AS GIVEN IN THE TABLE OF MINIMUM SECTION PROPERTIES. E. COLD-FORMED FRAMING NOMENCLATURE SHALL FOLLOW SSMA DESIGNATION AS FOLLOWS: F. MINIMUM COLD-FORMED MEMBER SIZE REQUIREMENTS: UNLESS OTHERWISE SHOWN ON THE DRAWINGS, COLD-FORMED MEMBERS SHALL CONFORM TO THE FOLLOWING MINIMUM REQUIREMENTS: a. STUDS AND JOISTS: THICKNESS SHALL BE 43 MILS (18 GAGE) AND HAVE 162 WIDE FLANGES (1-5/8"). b. TRACK: THICKNESS SHALL MATCH WALL OR JOIST FRAMING AND HAVE 125 DEEP LEGS (1-1/4"). c. DEEP LEG TRACK (DEFLECTION TRACK): THICKNESS SHALL BE 97 MILS (12 GAGE) AND HAVE 200 DEEP LEGS (2"). G. FASTENERS: a. UNLESS SHOWN OTHERWISE ON THE DRAWINGS, PROVIDE TRAXX#10, SELF-DRILLING FASTENERS AT ALL COLD-FORMED FRAMING CONNECTIONS (MINIMUM TWO SCREWS PER CONNECTION). PROVIDE SUFFICIENT NUMBER OF SCREWS AT EACH CONNECTION TO SUPPORT ALL APPLIED LOADS. b. PROVIDE HILTI POWDER-ACTUATED, UNIVERSAL KNURLED SHANK FASTENERS (X-U) TO ATTACH COLD-FORMED FRAMING TO CONCRETE SUBSTRATES. PROVIDE SUFFICIENT NUMBER OF FASTENERS TO TRANSFER ALL LOADS INTO CONCRETE. (MAXIMUM SPACING OF FASTENERS NO GREATER THAN STUD SPACING). c. WELDS: UNLESS NOTED OTHERWISE ON THE DRAWINGS, WELDS SHALL BE FILLET WELDS (MINIMUM TWO-3/4" LONG WELDS PER CONNECTION). PAINT ALL WELDS IN EXTERIOR WALL CONSTRUCTION WITH ZINC-RICH PAINT. H. INSTALLATION: a. SPLICING OF STUDS AND JOISTS SHALL NOT BE PERMITTED. b. ALL CORNERS SHALL BE FRAMED WITH A MINIMUM OF THREE STUDS OF THE SAME DEPTH AND GAGE AS WALL STUDS, UNLESS NOTED OTHERWISE. c. FRAME WALL OPENINGS WITH HEADERS, KING AND JAMB STUDS AS REQUIRED. d. MULTIPLE STUDS AT JAMBS OF OPENINGS SHALL BE SECURED TOGETHER WITH EITHER SELF- DRILLING FASTENERS OR 3/4" LONG FILLET WELDS AT EACH FLANGE AT 12" O.C. UNLESS NOTED OTHERWISE. e. BRACE WALL STUDS USING EITHER COLD-ROLLED CHANNELS THROUGH PUNCH-OUTS OR BY HORIZONTAL STRAPS AT EACH FLANGE WITH TRACK BLOCKING. BRACING SHALL CONFORM TO SECTION D3 OF THE AISI SPECIFICATION. f. NON-LOAD BEARING FRAMING: 1. PROVIDE JACK STUDS OR CRIPPLES BELOW WINDOW SILLS, ABOVE WINDOW AND DOOR HEADS AND ELSEWHERE AS REQUIRED. 2. PROVIDE DEFLECTION ALLOWANCE AT TOP OF ALL WALLS TO ACCOMMODATE STRUCTURAL MOVEMENT. SUBMIT DETAILS INCLUDING MANUFACTURER'S PRODUCT LITERATURE TO ARCHITECT AND ENGINEER FOR REVIEW. 3. PROVIDE SLIDE CLIPS AT CONNECTIONS WHERE WALLS EXTEND PAST EDGE OF FLOORS OR ROOF AS SHOWN ON THE DRAWINGS. SUBMIT DETAILS INCLUDING MANUFACTURER'S PRODUCT LITERATURE TO ARCHITECT AND ENGINEER FOR REVIEW. A. THE CONTRACTOR SHALL PROVIDE COMPLETE DRAWINGS AND CALCULATIONS FOR ALL STAIR CONSTRUCTION NOT SHOWN ON THE STRUCTURAL DRAWINGS. STAIR AND LANDING FRAMING SHALL BE DESIGNED AND DETAILED BY A PROFESSIONAL ENGINEER LICENSED IN THE PROJECT JURISDICTION. REFER TO PROJECT SPECIFICATIONS FOR SUBMITTAL REQUIREMENTS. B. DESIGN REQUIREMENTS: a. STAIRWAY FRAMING, LANDINGS AND ALL SUPPORT FRAMING SHALL BE DESIGNED FOR DEAD LOADS, SEISMIC LOADS AND LIVE LOADS PER THE REQUIREMENTS OF THE REFERENCED BUILDING CODE. b. REFER TO ARCHITECTURAL DRAWINGS FOR STAIRWAY WIDTHS AND CLEARANCES. MINIMUM HEADROOM CLEARANCES SHALL COMPLY WITH REQUIREMENTS OF THE REFERENCED BUILDING CODE. c. ALL REQUIRED EMBEDDED PLATES AND ANGLES SHALL BE INCLUDED AS PART OF THE STAIR DESIGN. d. THE STAIR MANUFACTURER SHALL PROVIDE ALL FRAMING, CONNECTIONS AND ACCESSORIES AS NECESSARY TO SUPPORT STAIRS FROM THE PRIMARY STRUCTURE. CONNECTIONS TO PRIMARY FRAMING SHALL BE LOCATED AND DETAILED TO PROPERLY TRANSFER FORCES TO THE PRIMARY FRAMING WITHOUT CAUSING OVERLOAD OR DISTORTION OF THE SUPPORTING ELEMENTS. SECTION DEPTH (IN.) FLANGE WIDTH (IN.) 600-S162-54 STYLE: S = STUDS, T = TRACK MINIMUM THICKNESS (MILS) EXAMPLES: 600 = 6" DEPTH 362 = 3-5/8" DEPTH S162 = STUD, 1-5/8" FLANGE T125 = TRACK, 1-1/4" DEEP LEG 33 = 20 GAGE, 43 = 18 GAGE, 54 = 16 GAGE 6. STAIR DESIGN: 07-THERMAL AND MOISTURE PROTECTION A. PROVIDE HANDTOOLED JOINTS IN CAST-IN-PLACE CONCRETE TOPPING OVER PRECAST FRAMING SUITABLE FOR SEALING WITH SPECIFIED JOINT SEALANT. REFER TO STANDARD JOINT DETAIL ON STRUCTURAL DRAWINGS FOR GEOMETRY AND CONSTRUCTION OF JOINT. B. LOCATE JOINTS IN TOPPING DIRECTLY ABOVE ALL JOINTS BETWEEN PRECAST ELEMENTS INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING LOCATIONS: a. JOINTS BETWEEN DOUBLE TEES b. JOINTS BETWEEN TEES AND INVERTED TEE (IT), ELL BEAMS (L) OR RECTANGULAR (R) BEAMS c. JOINTS BETWEEN COLUMN FACES AND TEES AND BEAMS d. JOINTS BETWEEN WALL OR SPANDREL PANEL FACES AND TEES AND BEAMS e. ELSEWHERE AS NOTED ON DRAWINGS C. STRIKE JOINTS IN TOPPING USING STRAIGHTEDGE ONLY. A. SEAL ALL HORIZONTAL GARAGE DECKS AND RAMPS WITH THE SPECIFIED DECK SEALER AFTER SWEEPING AND WASHING DECKS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SEALER SHALL BE COMPATIBLE WITH CURING PRODUCT OR CURING PRODUCT SHALL BE REMOVED AND DECK SURFACE PREPARED FOR APPLICATION OF SEALER IN ACCORDANCE WITH THE SEALER MANUFACTURER'S INSTRUCTIONS. B. SEAL VERTICAL FACES OF WALLS, COLUMNS AND SPANDREL PANELS A HEIGHT OF AT LEAST 3'-0 ABOVE ADJACENT DECK SURFACE. C. APPLY THE SPECIFIED TRAFFIC COATING IN LOCATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS. TRAFFIC COATING SHALL BE COMPATIBLE WITH PREVIOUSLY APPLIED CURING OR SEALER PRODUCTS OR PRODUCTS SHALL BE REMOVED AND DECK SURFACE PREPARED FOR APPLICATION OF TRAFFIC COATING IN ACCORDANCE WITH THE TRAFFIC COATING MANUFACTURER'S INSTRUCTIONS. 2. GARAGE DECK SEALER AND TRAFFIC COATINGS: 1. GARAGE DECK JOINTS: (PRECAST WITH CIP TOPPING): 05-STEEL MINIMUM NUMBER OF BOLTS PER CONNECTION 1. STRUCTURAL STEEL: NUMBER OF BOLTS FRAMING MEMBER SIZES e. WELDED CONNECTIONS: 1. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AWS STANDARD QUALIFICATION TESTS. 2. WELD SIZES AND LENGTHS ARE SHOWN ON THE DRAWINGS. WELD SIZES ARE THE NET EFFECTIVE SIZE REQUIRED. INCREASE WELD SIZE IF GAPS EXIST AT FAYING SURFACE. MINIMUM FILLET WELD SIZE IS 3/16". 3. WELDS SHALL BE CONTINUOUS UNLESS SHOWN OTHERWISE. 4. GROOVE WELDS SHALL BE FULL PENETRATION WELDS UNLESS NOTED OTHERWISE. BACKING BARS AND RUNOFF TABS SHALL BE REMOVED AFTER WELDING IS COMPLETE. f. HEADED ANCHOR STUDS: WELD STUDS TO PLATES AND EMBEDDED ITEMS IN FABRICATOR'S SHOP WHERE POSSIBLE. FOR COMPOSITE CONSTRUCTION, FIELD WELD CONNECTORS THROUGH METAL DECK. PROVIDE WELDING WASHERS AT DECK GAGES LIGHTER THAN 22 GAGE. WELDS SHALL DEVELOP FULL STRENGTH OF CONNECTORS. WELDING FERRULES MUST BE REMOVED PRIOR TO INSPECTION AND PLACEMENT OF CONCRETE. g. ANCHOR BOLTS: PROVIDE ANCHOR BOLTS WITH HEX NUT TACK WELDED TO EMBEDDED END OF BOLT. E. GALVANIZING OF STEEL: a. ALL STEEL PERMANENTLY EXPOSED TO WEATHER INCLUDING STRUCTURAL SHAPES, PLATES AND FASTENERS SHALL BE PROTECTED BY HOT-DIP GALVANIZING OR PAINTED WITH A HIGH PERFORMANCE PAINT SYSTEM PER PROJECT SPECIFICATIONS. b. GALVANIZING: i. STRUCTURAL STEEL SHAPES AND PLATES SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A123 AND SHALL HAVE A MINIMUM COATING THICKNESS OF 3.9 MILS. FASTENERS SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A153 AND SHALL HAVE A MINIMUM COATING THICKNESS OF 1.7 MILS. FIELD WELDING AND OTHER DAMAGE TO GALVANIZING SHALL BE TOUCHED UP WITH ZINC RICH PAINT WITH A MINIMUM DRY FILM THICKNESS OF 4.0 MILS IN ACCORDANCE WITH ASTM A780. METAL DECK PERMANENTLY EXPOSED TO WEATHER SHALL BE PROTECTED BY A GALVANIZED FINISH (G90 THICKNESS, MINIMUM) IN ACCORDANCE WITH ASTM A653. c. STEEL LINTELS SUPPORTING ANCHORED VENEER SHALL BE GALVANIZED UNLESS NOTED OTHERWISE ON DRAWINGS OR IN SPECIFICATIONS. F. FIELD MODIFICATION OF STEEL: STRUCTURAL STEEL SHALL NOT BE CUT IN FIELD OR MODIFIED WITHOUT PRIOR APPROVAL OF THE ENGINEER. SPLICING STEEL MEMBERS IS NOT PERMITTED EXCEPT WHERE SHOWN ON THE DRAWINGS OR WHERE APPROVED BY THE ENGINEER. WHERE APPROVED, SPLICES SHALL NOT OCCUR AT LOCATIONS OF MAXIMUM STRESS AND SHALL DEVELOP THE FULL CAPACITY OF THE MEMBER. SPLICE DETAILS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO BEGINNING THE WORK. A. REFERENCE STANDARDS: STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE AISC MANUAL OF STEEL CONSTRUCTION AND THE AISC CODE OF STANDARD PRACTICE (REFERENCED EDITIONS) WITH EXCEPTIONS NOTED IN THE PROJECT SPECIFICATIONS. B. MATERIAL REQUIREMENTS: STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING DESIGNATIONS UNLESS NOTED OTHERWISE ON THE DRAWINGS OR IN THE SPECIFICATIONS: a. WIDE FLANGE SHAPES: ASTM 992, GRADE 50 b. ANGLES, CHANNELS AND PLATES: ASTM A36 OR ASTM A572, GRADE 50 c. ROUND HSS SECTIONS: ASTM A500, GRADE "B" (FY=42 KSI) d. RECTANGULAR HSS SECTIONS: ASTM A500, GRADE "B" (FY=46 KSI) e. STRUCTURAL PIPES: ASTM A53, GRADE "B" (FY=35 KSI) f. HIGH-STRENGTH BOLTS: ASTM A325 OR ASTM A490 g. ANCHOR BOLTS: ASTM F1554, GRADE 36 (WELDABLE) h. HEADED ANCHOR STUDS (H.A.S.): ASTM A108 AND AWS D1.1 i. DEFORMED BAR ANCHORS (D.B.A.): ASTM A496, GRADE 70 AND AWS D1.1 j. WELDING ELECTRODES: AWS D1.1 E70 SERIES k. GALVANIZED FINISH: ASTM A123 C. SHOP PRIMING OF STEEL: STRUCTURAL STEEL SCHEDULED TO BE SPRAYED WITH FIRE RESISTIVE MATERIAL SHALL NOT BE SHOP PRIMED UNLESS NOTED OTHERWISE. ALL OTHER STEEL SHALL BE PAINTED WITH FABRICATOR'S STANDARD, RUST-INHIBITING PRIMER. OMIT PRIMER ON SURFACES ENCLOSED IN CONCRETE, SURFACES TO BE WELDED, CONTACT SURFACES IN SLIP CRITICAL CONNECTIONS AND TOPS OF BEAMS IN COMPOSITE CONSTRUCTION. D. CONNECTIONS: a. PROVIDE STANDARD SIMPLE SHEAR BEAM CONNECTIONS AS SHOWN IN THE AISC STEEL CONSTRUCTION MANUAL (REFERENCED EDITION) SUBMITTED IN ACCORDANCE WITH THE SPECIFICATIONS, UNLESS NOTED OTHERWISE ON THE DRAWINGS. b. SEE SPECIFICATIONS FOR ADDITIONAL CONNECTIONS SUBMITTAL REQUIREMENTS FOR ALTERNATE CONNECTIONS AND FOR CONNECTIONS NOT COMPLETELY DETAILED OR NOT INDICATED ON THE DRAWINGS. c. SELECT CONNECTIONS TO SUPPORT THE REACTIONS SHOWN ON PLANS AND DETAILS. REACTIONS ARE GIVEN AS SERVICE LOADS USING ASD LOAD COMBINATIONS UNLESS NOTED OTHERWISE. WHERE REACTIONS ARE NOT SHOWN, PROVIDE CONNECTIONS TO SUPPORT A SERVICE LOAD OF 8.0 KIPS FOR ASD DESIGN OR A FACTORED LOAD OF 14.0 KIPS FOR LRFD DESIGN. d. BOLTED CONNECTIONS: 1. MINIMUM CONNECTION REQUIREMENT: USE 3/4" DIAMETER, ASTM A325 HIGH-STRENGTH BOLTS UNLESS NOTED OTHERWISE ON DRAWINGS. 2. FOR ALL HIGH-STRENGTH BOLTED CONNECTIONS, APPROPRIATE NUTS AND HARDENED WASHERS SHALL BE PROVIDED PER PROJECT SPECIFICATIONS. 3. ALL CONNECTIONS SHALL BE TYPE N (BEARING OR SNUG-TIGHTENED) CONNECTIONS UNLESS NOTED ON THE DRAWINGS AS TYPE SC (SLIP CRITICAL) OR PRETENSIONED (WITH TENSION CONTROL BOLTS). 4. PROVIDE A MINIMUM OF TWO BOLTS FOR ALL CONNECTIONS EXCEPT AS NOTED IN THE FOLLOWING TABLE: 2 W8, W10, W12, S8, S10, S12, C8, C9, C10, C12 MC8, MC9, MC10, MC12, MC13 3 W14, W16, W18, S15, S18 C15 MC18 4 W21, W24 S20, S24 5 W27, W30 6 W33, W36 7 W40, W44 4 4 3 3 A. REFERENCE STANDARDS: STEEL DECK SHALL BE DESIGNED, FABRICATED AND ERECTED IN ACCORDANCE WITH STANDARDS OF THE STEEL DECK INSTITUTE (SDI). B. ALL STEEL DECK AND DECK ACCESSORIES SHALL BE FABRICATED FROM SHEET STEEL CONFORMING TO ASTM A653 WITH G60 GALVANIZED FINISH. MINIMUM DECK YIELD STRESS SHALL CONFORM TO THE VALUES GIVEN IN THE TABLE OF MINIMUM DECK SECTION PROPERTIES. C. SPECIFIED STEEL DECK SHALL EXHIBIT THE FOLLOWING MINIMUM SECTION PROPERTIES: EDIT TABLE OR ADD/DELETE DECK TYPES TO FIT PROJECT REQUIREMENTS MINIMUM DECK SECTION PROPERTIES DECK GAGE (YIELD STRESS) DECK TYPE USE Sp Ip (IN /FT) In (IN /FT) (IN /FT) Sn (IN /FT) 2. ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS): 3. MISCELLANEOUS STRUCTURAL STEEL: a. STEEL DECK PROPERTIES LISTED IN TABLE ABOVE CONFORM TO DECK PRODUCED BY VULCRAFT. STEEL DECK FROM OTHER SUPPLIERS MAY BE SUPPLIED PROVIDED SECTION PROPERTIES ARE SIMILAR, LOAD CAPACITY IS EQUIVALENT, CONSTRUCTION SPANS ARE EQUAL OR GREATER, AND SUBSTITUTION IS APPROVED BY THE STRUCTURAL ENGINEER. b. THE CONTRACTOR SHALL PROVIDE ADDITIONAL SHEAR STUDS IF ALTERNATE DECK TYPE REQUIRES MORE STUDS THAN SPECIFIED FOR COMPOSITE BEAMS TO MEET LEVEL OF COMPOSITE ACTION ACHIEVED USING ORIGINAL DECK TYPE. D. INSTALLATION: a. DECKING SHALL BE 3-SPAN CONTINUOUS (FOUR SUPPORTS) AS A MINIMUM UNLESS NOTED OTHERWISE. b. DECK SHALL BEAR A MINIMUM OF 1-1/2" AT SUPPORTS. c. ROOF DECK ENDLAPS SHALL BE A MINIMUM OF 2" d. STEEL DECK SHALL BE FASTENED TO SUPPORTS PER INSTRUCTIONS ON THE PLANS OR SPECIFICATIONS BUT NOT LESS THAN REQUIRED BY SDI. e. DECK SHALL NOT BE SHORED DURING PLACEMENT OF CONCRETE UNLESS APPROVED BY THE STRUCTURAL ENGINEER. E. OPENINGS THROUGH STEEL DECK: SEE REQUIREMENTS GIVEN IN THE MISCELLANEOUS STRUCTURAL STEEL SECTION IN THESE GENERAL NOTES. F. HANGERS SUPPORTING DUCTWORK OR MECHANICAL EQUIPMENT SHALL NOT BE SUSPENDED FROM STEEL ROOF DECK. ATTACH HANGERS DIRECTLY TO MAIN ROOF FRAMING OR PROVIDE ADDITIONAL MISCELLANEOUS STEEL FRAMING CONNECTED TO MAIN ROOF FRAMING. 20 (50) 0.409 0.406 0.341 0.346 20 (50) 0.920 0.919 0.534 0.551 20 (33) 0.201 0.222 0.234 0.247 20 (33) 0.848 1.079 0.501 0.552 A. MISCELLANEOUS STRUCTURAL STEEL IS DEFINED FOR THE PURPOSE OF THIS SECTION AS STEEL ITEMS OTHER THAN THE MAIN SUPERSTRUCTURE FRAMING (COLUMNS, BEAMS, JOISTS, GIRDERS, TRUSSES AND LATERAL BRACING). B. THE STEEL SUPPLIER SHALL PROVIDE ALL MISCELLANEOUS STRUCTURAL STEEL ITEMS NECESSARY TO FULFILL THE INTENT OF THE STRUCTURAL DRAWINGS WHETHER OR NOT THE ITEMS ARE SHOWN ON THE STRUCTURAL DRAWINGS. SUCH ITEMS MAY INCLUDE BUT ARE NOT LIMITED TO: EDGE ANGLES, CLOSURE PLATES AND DECK SUPPORT FRAMING. C. DECK OPENINGS: FLOOR AND ROOF OPENINGS ARE SHOWN ON ARCHITECTURAL, STRUCTURAL, AND OTHER DISCIPLINE DRAWINGS. IF OPENINGS ARE NOT SHOWN, LOCATED OR DIMENSIONED ON STRUCTURAL DRAWINGS, REFER TO DRAWINGS LISTED ABOVE FOR REQUIRED INFORMATION. UNLESS OTHERWISE NOTED, ALL OPENINGS THROUGH FLOOR AND ROOF DECK SHALL BE FRAMED USING MISCELLANEOUS STRUCTURAL STEEL FRAMES OR REINFORCING AS FOLLOWS: a. DECK SUPPORTING CONCRETE: 1. FOR OPENINGS WITH THE LARGEST DIMENSION LESS THAN 24", PROVIDE 1-#5 BAR IN CONCRETE ABOVE DECK FLUTES ON EACH SIDE OF OPENING. EXTEND REINFORCING A MINIMUM OF 24" BEYOND EDGES OF OPENING OR PROVIDE A STANDARD HOOK. OPENINGS SHALL BE SPACED A MINIMUM OF 24" CLEAR. IF SPACING REQUIREMENT CANNOT BE MET, THE OPENINGS SHALL BE CONSIDERED AS ONE LARGE OPENING AND A STEEL FRAME AROUND OPENINGS SHALL BE PROVIDED AS DESCRIBED BELOW. 2. FOR ALL OTHER OPENINGS, PROVIDE A STEEL FRAME AROUND OPENING PER TYPICAL OPENING FRAME DETAIL PROVIDED ON STRUCTURAL DRAWINGS. b. ROOF DECK (NO CONCRETE TOPPING): 1. NO ADDITIONAL DECK SUPPORT FRAMING IS REQUIRED FOR OPENINGS WITH THE LARGEST DIMENSION LESS THAN OR EQUAL TO 10". OPENINGS IN THIS CATEGORY MUST BE SPACED A MINIMUM OF 24" APART (CLEAR) WHEN OPENINGS ARE NOT ALIGNED PARALLEL TO DIRECTION OF FLUTES. IF SPACING REQUIREMENT CANNOT BE MET, THE OPENINGS SHALL BE CONSIDERED AS ONE LARGE OPENING AND A DECK SUPPORT FRAME SHALL BE PROVIDED AS DESCRIBED BELOW. 2. FOR ALL OTHER OPENINGS, PROVIDE A STEEL FRAME AROUND OPENINGS PER TYPICAL OPENING FRAME DETAIL PROVIDED ON STRUCTURAL DRAWINGS. ROOF DECK COMPOSITE DECK 2 VLI 3 VLI 1.5B 3N A. STRUCTURAL STEEL NOTED AS AESS ON THE STRUCTURAL DRAWINGS SHALL BE CLASSIFIED AS CATEGORY 1 UNLESS OTHERWISE SPECIFIED. REFER TO PROJECT SPECIFICATIONS FOR DETAILING, FABRICATION AND ERECTION REQUIREMENTS FOR AESS. B. FABRICATION OF AESS SHALL HAVE WELDS GROUND SMOOTH, MILL MARKS REMOVED AND PIECE MARKS HIDDEN. SURFACE PREPARATION SHALL CONFORM TO SSPC SP-3 POWER TOOL CLEANING. C. UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS, FIELD WELDS EXPOSED TO VIEW SHALL BE MADE CONTINUOUS AND GROUND SMOOTH WITH BACKING BARS AND RUNOFF TABS REMOVED. 4. STEEL DECK: A. UNLESS NOTED OTHERWISE ON THE ARCHITECTURAL DRAWINGS OR PROJECT SPECIFICATIONS, ANCHOR BRICK OR STONE VENEER TO BACKING AS DESCRIBED IN THE FOLLOWING PARAGRAPHS. B. ANCHORS: VENEER ANCHORS SHALL BE ADJUSTABLE, TWO-PIECE ANCHORS WITH A MINIMUM W1.7 WIRE SIZE. SUBMIT ANCHOR INFORMATION TO ARCHITECT FOR REVIEW AND APPROVAL. C. ANCHOR SPACING: LOCATE ANCHORS AT THE FOLLOWING MAXIMUM SPACING: a. UNLESS OTHERWISE DIRECTED BY THE FOLLOWING PARAGRAPHS, LOCATE ANCHORS AT 24" ON CENTER VERTICAL AND 16" ON CENTER HORIZONTAL MAXIMUM SPACING. b. FOR SEISMIC DESIGN CATEGORIES D, E AND F: LOCATE ANCHORS AT 16" ON CENTER VERTICALLY AND 16" ON CENTER HORIZONTALLY MAXIMUM SPACING. c. REFER TO SECTION 01-GENERAL REQUIREMENTS, PARAGRAPH 6.F IN THE GENERAL NOTES FOR SEISMIC DESIGN CATEGORY. D. BACKING SUPPORT OF VENEER: COLD-FORMED FRAMING USED AS BACKING FOR ANCHORED VENEER SHALL BE 18 GAGE MINIMUM, GALVANIZED, SPACED AT 16" ON CENTER. SCREWS USED TO FASTEN ANCHORS TO STUDS SHALL HAVE A MINIMUM SHANK DIAMETER OF 0.190". E. RELIEF ANGLE SUPPORTS: UNLESS SHOWN OTHERWISE ON THE DRAWINGS, STEEL RELIEF ANGLES SHALL BE GALVANIZED AND HAVE A MINIMUM LEG THICKNESS OF 3/8". PROVIDE A MINIMUM CLEAR GAP OF 3/8" BETWEEN BOTTOM OF ANGLE AND TOP OF VENEER BELOW. 2. ANCHORED VENEER: STRUCTURAL GENERAL NOTES Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:22 PM S-002 STRUCTURAL GENERAL NOTES 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE THICKNESS PROVIDED SCHEDULE OF FIRE PROTECTION PROVISIONS NOTES: 1. PROTECT STRUCTURAL STEEL FRAMING (COLUMNS, BEAM, GIRDERS, SPANDREL BEAMS) WITH SPRAY-APPLIED FIRE RESISTIVE MATERIALS, GYP-BOARD ASSEMBLIES OR INTUMESCENT PAINT PER ARCHITECTURAL PLANS AND SPECIFICATIONS. SPRAY-APPLIED FIRE RESISTIVE MATERIAL SHALL HAVE A MINIMUM AVERAGE DENSITY OF 15 PCF AND SHALL BE APPLIED WITH A MINIMUM THICKNESS TO PROVIDE THE FIRE RESISTIVE RATING PERIOD REQUIRED. FLOOR SLAB 2-HOUR N.W. 4-1/2" 4-1/2" NA NA D916 RESTRAINED GARAGE FLOOR SLAB 2-HOUR N.W. VARIES, 5" MINIMUM 5" 1-1/2" 2-1/2" J942 RESTRAINED 1-3 HOURS N.W. 1-1/2" NA NA 1-3 HOURS N.W. NA 1-1/2" 3" RESTRAINED PRECAST WALLS 3-HOUR N.W. 5.7" 3/4" NA NA IBC TABLE 721.1 (2) N901, N902, N903 IBC TABLE 721.1(1) NORMAL-WEIGHT CONCRETE TOPPING ON PRECAST CONCRETE FRAMING PRECAST COLUMNS PRECAST IT-BEAMS, L-BEAMS, RECTANGULAR BEAMS STRUCTURAL FRAME STRUCTURAL FRAME STRUCTURAL FRAME NORMAL-WEIGHT CONCRETE ON COMPOSITE STEEL DECK SEE PLANS SEE PLANS SEE PLANS 12" OR LARGER LOCATION/ DESCRIPTION ZONE 10 120 0 125 40 130 WIND SUCTION WIND PRESSURE 24.1 PSF ROOF AT EDGES ROOF NOT AT EDGES/CORNERS 2 ROOF AT CORNERS 3 WALLS NOT AT CORNERS 4 WALLS AT CORNERS 5 44.0 PSF CLAY SAND & GRAVEL CLAYSTONE COHESION, c (PSI) DENSITY (PCF) SOIL TYPE DESIGN PARAMETER OVERBURDEN SOILS (ABOVE BEDROCK) BEDROCK INTERNAL FRICTION ANGLE, phi (DEGREES) STRAIN AT 50% OF PEAK SHEAR STRENGTH, e (IN/IN) INITIAL MODULUS OF HORIZONTAL SUBGRADE REACTION, k (PCI) INITIAL MODULUS OF HORIZONTAL SUBGRADE REACTION FOR CYCLIC LOADING, k (PCI) 1 50 S C F. DESCRIPTION OF LATERAL LOAD-RESISTING SYSTEM: a. THE LATERAL LOAD-RESISTING ELEMENTS THAT PROVIDE LATERAL STRENGTH AND STABILITY OF THE COMPLETED STRUCTURE ARE AS FOLLOWS: 1. CONCRETE SHEAR WALLS (CAST-IN-PLACE OR PRECAST CONCRETE) b. THE DIAPHRAGM ELEMENTS WITHIN THE LATERAL LOAD-RESISTING SYSTEM ARE AS FOLLOWS: 1. STEEL ROOF DECK, INCLUDING THE CONNECTIONS OF THE STEEL DECK TO THE LATERAL LOAD-RESISTING ELEMENTS. 2. CONCRETE ROOF AND FLOOR SLABS COMPRISED OF CONCRETE TOPPING OVER PRECAST FLOOR FRAMING INCLUDING CONNECTIONS BETWEEN PRECAST FRAMING, AND CONNECTIONS OF THE SLABS TO THE LATERAL LOAD-RESISTING ELEMENTS. c. SEE DETAILS FOR SPECIAL ERECTION CONSIDERATIONS AND LATERAL LOAD-RESISTING SYSTEM COMPONENTS NOT LISTED HERE. d. TEMPORARY BRACING: DURING BUILDING ERECTION, THE STEEL ERECTOR SHALL DETERMINE, FURNISH AND INSTALL ALL TEMPORARY SUPPORTS AND BRACING NECESSARY FOR LATERAL STABILITY OF THE SUPERSTRUCTURE UNTIL THE LATERAL LOAD-RESISTING ELEMENTS AND DIAPHRAGMS ARE IN PLACE AND ALL CONNECTIONS ARE COMPLETE. 5. DESIGN LOAD CRITERIA: a. ALL PARAPETS AND OTHER FEATURES WITH WIND EXPOSURE ON OPPOSITE SIDES SHALL BE DESIGNED FOR ± 78.8 PSF. b. CANOPIES AND OVERHANGS: REFER TO ASCE 7 FOR DESIGN PROCEDURES TO DETERMINE COMPONENT AND CLADDING WIND LOADING REQUIREMENTS. G. SPECIAL LOAD REQUIREMENTS ARE DESCRIBED IN PLAN NOTES OR SPECIFIC LOCATIONS ON THE CONTRACT DRAWINGS. NOTES: 1. VALUES GIVEN ABOVE ARE FOR EFFECTIVE WIND AREAS OF 10 SQUARE FEET OR LESS. VALUES MAY BE REDUCED FOR AREAS GREATER THAN 10 SQUARE FEET IN ACCORDANCE WITH PROCEDURES GIVEN IN ASCE 7 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES". 2. VALUES GIVEN ABOVE WERE DETERMINED AT A MEAN ROOF HEIGHT OF 26.0 FT. WIND PRESSURE VALUES MAY BE REDUCED FOR COMPONENTS AT LOWER ELEVATIONS IN ACCORDANCE WITH PROCEDURES GIVEN IN ASCE 7 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES". 3. PRESSURE INDICATES LOAD ACTING TOWARDS SURFACES. SUCTION INDICATES LOAD ACTING AWAY FROM SURFACES. 4. REFER TO ASCE 7 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES", TABLE 30.7-2, FOR DEFINITION OF ZONES. 5. THE VALUES ABOVE DO NOT APPLY TO CHIMNEYS, TANKS, ROOFTOP EQUIPMENT, SIGNS OR OTHER SIMILAR STRUCTURES. 6. CLADDING AND COMPONENTS SHALL BE DESIGNED FOR MAXIMUM PRESSURE AND SUCTION ACTING INDEPENDENTLY. A. GEOTECHNICAL REPORT: FOUNDATION DESIGN CRITERIA WAS TAKEN FROM RECOMMENDATIONS SET FORTH IN GEOTECHNICAL REPORT NO. 2014-5072 BY TERRACON CONSULTANTS INC., DATED JAN. 20 2015. B. ALLOWABLE DRILLED PIER SOIL CAPACITIES USED FOR DESIGN: END BEARING . . . . . . . . . . . . . . . . . . . SIDE SHEAR (DOWNWARD LOADS) . . . . . . . . SIDE SHEAR (UPWARD LOADS) . . . . . . . . . . C. ALLOWABLE DRILLED PIER SOIL CAPACITIES USED FOR DESIGN: D. MODULUS OF SUBGRADE REACTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 PSI E. LATERALLY LOADED PIER DESIGN CRITERIA: 1. FOUNDATION DESIGN CRITERIA: 02-FOUNDATION CONSTRUCTION F. LATERAL EARTH PRESSURE FOR ON-SITE SOIL MATERIAL (DOES NOT INCLUDE HYDROSTATIC OR SURCHARGE LOADS): AT-REST CONDITION . . . . . . . . . . . . . . . . . . . . . ACTIVE CONDITION . . . . . . . . . . . . . . . . . . . . . . PASSIVE CONDITION . . . . . . . . . . . . . . . . . . . . G. MINIMUM FROST DEPTH IS 30 INCHES. 35 PCF 56 PCF 480 PCF A. DRILLED PIERS SHALL BE CONSTRUCTED USING DRY EXCAVATION METHODS. SLURRY EXCAVATION METHODS SHALL NOT BE USED WITHOUT APPROVAL FROM ARCHITECT, STRUCTURAL ENGINEER AND GEOTECHNICAL ENGINEER. B. STABILIZE PIER EXCAVATION SIDEWALLS USING TEMPORARY STEEL CASING AS REQUIRED. STEEL CASING SHALL BE REMOVED DURING CONCRETE PLACEMENT AND OBSERVED BY THE GEOTECHNICAL ENGINEER. C. INSIDE DIAMETER OF CASING SHALL NOT BE LESS THAN THE SPECIFIED PIER DIAMETER. D. CONSTRUCT SHEAR RINGS OVER LENGTH OF PIER IN BEDROCK. SEE STANDARD DRILLED PIER DETAIL FOR ADDITIONAL INFORMATION. INSTALLATION OF SHEAR RINGS SHALL BE OBSERVED AND APPROVED BY THE GEOTECHNICAL ENGINEER. E. IF REQUIRED, SPLICE PIER REINFORCING USING CLASS B LAP SPLICE. DO NOT SPLICE VERTICAL REINFORCING WITHIN THE TOP 30' OF PIER LENGTH. LONGITUDINAL PIER REINFORCING SHALL EXTEND THE FULL LENGTH OF PIER. UNLESS NOTED OTHERWISE ON PLANS OR DETAILS, REINFORCING SHALL NOT TERMINATE HIGHER THAN 18" FROM BOTTOM OF EXCAVATION. F. MINIMUM PIER PENETRATION INTO BEDROCK IS 10'-0" FEET. 2. DRILLED PIERS: 03-CONCRETE F1 F0 P1 P0 C1 C0 S0 S0 NW NW 4,000 4,000 FOUNDATIONS (WALLS, GRADE BEAMS, PILASTERS, PIER CAPS) DRILLED PIERS DESCRIPTION OF CONCRETE USE CONCRETE TYPE D. DURABILITY REQUIREMENTS: CONCRETE MIXES USED ON THE PROJECT SHALL BE PROPORTIONED TO SATISFY THE FOLLOWING DURABILITY REQUIREMENTS: F0 P0 C1 DESCRIPTION OF CONCRETE USE AND / OR EXPOSURE FREEZE-THAW (ACI 318, 4.2.1) PERMEABILITY (ACI 318, 4.2.1) CHLORIDES (ACI 318, 4.2.1) SULFATES (ACI 318, 4.2.1) EXTERIOR EXPOSURE (FLOORS, ROOFS) PARKING GARAGE (ALL CONCRETE) 28-DAY COMPRESSIVE STRENGTH (PSI) INTERIOR SLABS-ON-GRADE NW 3,500 PARKING GARAGE SLABS-ON-GRADE NW 4,500 NORMAL WEIGHT TOPPING ON METAL DECK NW 3,500 PARKING GARAGE TOPPING ON PRECAST TEES NW 5,000 ALL OTHER CONCRETE NW 4,000 NOTES: 1. NORMAL WEIGHT CONCRETE (NW): 145 PCF, STONE AGGREGATE. 2. LIGHT-WEIGHT CONCRETE (LW): 110 PCF, LIGHT-WEIGHT COARSE AGGREGATE. FOUNDATIONS (PIERS, WALLS, GRADE BEAMS) INTERIOR EXPOSURE (ALL CONCRETE) EXTERIOR EXPOSURE (VERTICAL CONCRETE ONLY) F2 P1 C1 S0 F3 P1 C2 S0 NOTES: 1. REFER TO ACI 318, CHAPTER 4 DEFINITION OF EXPOSURE CLASSIFICATIONS. 2. CONCRETE USED IN POST-TENSIONED CONCRETE IN ANY EXPOSURE CLASSIFICATION SHALL BE LIMITED TO A CHLORIDE ION CONTENT OF 0.06% OR LESS (ACI 318.4.3.1). 3. BUILDING PAD PREPARATION: A. ALL EARTHWORK AND SITE PREPARATION SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND GEOTECHNICAL REPORT. ALL EXCAVATION AND BACKFILL OPERATIONS SHALL BE OBSERVED AND APPROVED BY THE GEOTECHNICAL ENGINEER. B. OVEREXCAVATE BUILDING SITE TO A DEPTH OF X.XX FT. FROM THE PROPOSED FINISHED FLOOR ELEVATION, OR, X.XX FEET BELOW THE BOTTOM OF FOOTINGS. BACKFILL WITH RECONDITIONED, ON-SITE SOIL MATERIAL (IMPORTED, STRUCTURAL FILL MATERIAL) AND COMPACT IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. FILL MATERIAL MUST BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. C. UNSUITABLE SOILS ENCOUNTERED AT THE BOTTOM OF THE SPECIFIED EXCAVATION SHALL BE REMOVED AND REPLACED WITH STRUCTURAL FILL COMPACTED PER PARAGRAPH B ABOVE. D. DO NOT EXCAVATE BELOW THE BOTTOM OF EXISTING FOOTINGS. EXCAVATIONS ADJACENT TO EXISTING FOOTINGS SHALL BE OBSERVED AND APPROVED BY THE GEOTECHNICAL ENGINEER. E. PLACE X" THICK LAYER OF IMPERVIOUS SOIL MATERIAL OVER BACKFILL. REFER TO PROJECT SPECIFICATIONS FOR DESCRIPTION OF SOIL MATERIAL AND COMPACTION REQUIREMENTS. F. ROUGH GRADE TOP OF SUBGRADE TO +0",-1.5" TOLERANCE FROM SPECIFIED ELEVATION. 4. SLAB-ON-GRADE AND FOUNDATION CONSTRUCTION REQUIREMENTS A. VOID SPACES: PROVIDE A MINIMUM 4" HIGH, CONTINUOUS VOID SPACE BENEATH ALL FOUNDATION WALLS, GRADE BEAMS, PIER CAPS, ETC. B. PROVIDE A GRANULAR SUB-BASE MATERIAL BELOW SLABS-ON-GRADE IN ACCORDANCE WITH THE PLANS AND PROJECT SPECIFICATIONS. FINE GRADE TOP OF SUB-GRADE TO +0",-3/4" FROM SPECIFIED ELEVATION. C. VAPOR BARRIER: PROVIDE A VAPOR BARRIER ON TOP OF SUB-BASE AND DIRECTLY BELOW THE SLAB-ON-GRADE AT FLOORS SCHEDULED TO BE FINISHED WITH WATER-SENSITIVE FINISHES. REFER TO THE PROJECT SPECIFICATIONS FOR A DESCRIPTION OF THE VAPOR BARRIER MATERIAL. D. ISOLATION JOINTS: PROVIDE 3/8" WIDE ISOLATION JOINT AT THE EDGES OF ALL SLABS-ON-GRADE ABUTTING VERTICAL CONSTRUCTION (COLUMNS, WALLS, GRADE BEAMS, ETC.) E. SLIP JOINTS: PROVIDE SLIP JOINTS AT THE TOP OF ALL PARTITION WALLS SUPPORTED BY THE SLAB-ON-GRADE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. F. PERIMETER DRAIN: PROVIDE A PERIMETER DRAIN AROUND THE BUILDING IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND GEOTECHNICAL REPORT. REFER TO CIVIL DRAWINGS FOR ADDITIONAL INFORMATION. FOUNDATION WALLS HAVE NOT BEEN DESIGNED TO RESIST HYDROSTATIC PRESSURE. A. ALL CONCRETE WORK INCLUDING FABRICATION AND PLACEMENT OF REINFORCING SHALL BE PERFORMED IN ACCORDANCE WITH REQUIREMENTS GIVEN IN ACI 318 AND ACI 301 (REFERENCED EDITIONS) EXCEPT AS MODIFIED BY THE PROJECT CONTRACT DOCUMENTS. B. CONCRETE MIXES SHALL SATISFY THE REQUIREMENTS GIVEN IN THE PROJECT SPECIFICATIONS. C. CONCRETE STRENGTH: CONCRETE MIXES USED ON THE PROJECT SHALL ATTAIN 28-DAY COMPRESSIVE STRENGTHS AS FOLLOWS: 1. CAST-IN-PLACE CONCRETE: CONCRETE STRENGTH=5000 psi CONCRETE STRENGTH=4000 psi CONCRETE STRENGTH=4500 psi BAR CASE SIZE BAR CASE SIZE BAR CASE SIZE NOTES: 1. UNLESS SPECIFICALLY INDICATED OTHERWISE ON THE CONTRACT DRAWINGS, USE THE MINIMUM LENGTH FOR A CLASS B LAP SPLICE OR THE MINIMUM DEVELOPMENT LENGTH INDICATED IN THE TABLES ABOVE MULTIPLIED BY THE APPLICABLE FACTOR(S) LISTED BELOW. 2. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12 INCHES OF CONCRETE CAST BELOW THE BARS. 3. WHERE THE CLEAR SPACING BETWEEN BARS LAP SPLICED OR EMBEDDED AT ANY SECTION IS LESS THAN 2 BAR DIAMETERS, OR WHERE THE BAR COVER IS LESS THAN OR EQUAL TO THE BAR DIAMETER. INCREASE THE TABULATED BAR SPLICE OR DEVELOPMENT LENGTH BY 50%. 4. TABLE IS FOR 1 OR 2 BAR BUNDLES ONLY. FOR DEVELOPMENT LENGTHS AND TENSION LAP SPLICE LENGTHS OF BUNDLED BARS REFER TO ACI 318-11, 12.4 OR CONTACT THE STRUCTURAL ENGINEER. 5. MECHANICAL COUPLERS MAY BE SUBSTITUTED FOR TENSION LAP SPLICED BARS PROVIDED THAT THEY MEET THE REQUIREMENTS OF ACI 318-11, 12.14. #3 17 13 22 17 #4 23 17 29 23 #5 28 22 36 28 #6 34 26 43 34 #7 49 38 63 49 #8 56 43 72 56 #9 63 48 81 63 #10 70 54 92 70 #11 78 60 102 78 TOP BARS OTHER BARS CLASS B LAP TOP BARS OTHER BARS #3 18 14 23 18 #4 24 18 31 24 #5 30 23 38 30 #6 35 27 46 35 #7 51 40 67 51 #8 59 45 76 59 #9 66 51 86 66 #10 74 57 96 74 #11 82 64 107 82 #3 19 15 24 19 #4 25 19 33 25 #5 31 24 41 31 #6 37 29 49 37 #7 54 42 71 54 #8 62 48 81 62 #9 70 54 91 70 #10 79 61 102 79 #11 87 67 113 87 DEVELOPMENT LENGTH OR CLASS A LAP DEVELOPMENT LENGTH OR CLASS A LAP CLASS B LAP TOP BARS OTHER BARS TOP BARS OTHER BARS CLASS B LAP DEVELOPMENT LENGTH OR CLASS A LAP TOP BARS OTHER BARS TOP BARS OTHER BARS L. WELDING OF REINFORCING IS NOT ALLOWED UNLESS DETAILED OR AUTHORIZED BY THE STRUCTURAL ENGINEER. M. PLACING OF REINFORCING: a. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING AT POSITIONS SHOWN ON PLANS AND TO MAINTAIN REQUIRED CONCRETE COVER. b. PROVIDE ADDITIONAL BARS AND SUPPORTS AS NECESSARY TO SECURE REINFORCING IN PLACE DURING CONCRETE PLACEMENT. c. ALL STIRRUPS SHALL HAVE A #3 SPACER BAR AT ALL CORNERS OVER LENGTH OF STIRRUP SPACING WHERE NO OTHER LONGITUDINAL REINFORCING BAR IS PRESENT. d. WET-STABBING OF REINFORCING OR EMBEDS INTO PREVIOUSLY PLACED CONCRETE IS NOT ALLOWED. N. CONTROL JOINTS IN CONCRETE: a. PROVIDE CONTROL JOINTS IN CONCRETE WALLS AT A MAXIMUM SPACING OF 30'-0 ON CENTER. SEAL CONTROL JOINTS EXPOSED TO EARTH OR WEATHER WITH JOINT SEALANT. b. PROVIDE CONTROL JOINTS IN SLABS-ON-GRADE AT A MAXIMUM SPACING OF 12'-0 ON CENTER UNLESS OTHERWISE SHOWN ON PLAN OR IN DETAILS. COORDINATE JOINT LOCATIONS WITH FLOOR FINISHES AND LOCATE JOINTS AT COLUMN CENTERLINES, AT ENDS AND CORNERS OF WALLS, RE-ENTRANT CORNERS AND LOCATIONS PRONE TO CRACKING WHERE POSSIBLE. CONTRACTOR SHALL SUBMIT A PLAN LOCATING CONTROL JOINTS TO ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO PROCEEDING WITH THE WORK. O. CONSTRUCTION JOINTS: a. LOCATE CONSTRUCTION JOINTS AT CONTROL JOINT LOCATIONS WHERE POSSIBLE. MAINTAIN REQUIRED CONCRETE COVER. b. SLABS, BEAMS, AND JOISTS SHALL NOT HAVE CONSTRUCTION JOINTS IN A HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK MUST BE MADE AT THIRD POINT OF SPAN WITH VERTICAL BULKHEADS AND HORIZONTAL KEYS, UNLESS OTHERWISE SHOWN. ALL CONSTRUCTION JOINTS SHALL BE AS DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. c. FOR CONCRETE POURED ON METAL DECK, LOCATE CONSTRUCTION JOINTS FIVE FEET FROM THE CENTERLINE OF PARALLEL STEEL BEAMS OR GIRDERS, OR, HALFWAY BETWEEN ADJACENT BEAMS, WHICH EVER IS LESS. d. ALL REINFORCING SHALL BE CONTINUOUS THROUGH CONSTRUCTION JOINTS, OR, PROVIDE DOWEL BAR SPLICERS CAPABLE OF DEVELOPING THE STRENGTH OF THE REINFORCING. LAP SPLICE DOWEL BAR EXTENSION AND DOWEL BAR SPLICER TO REINFORCING USING CLASS 'B' LAP SPLICES. P. CONCRETE TOLERANCES: TOLERANCES SHALL CONFORM TO REQUIREMENTS GIVEN IN ACI 117 AND THE FOLLOWING ADDITIONAL REQUIREMENTS: a. ALIGNMENT OF WALLS AND COLUMNS: 1. FOR HEIGHTS 100 FEET OR LESS ADJACENT TO STONE OR BRICK VENEER. +0.50" OR -0.50" FROM THEORETICAL PLAN LOCATION. 2. ALIGNMENT DIFFERENCE BETWEEN ADJACENT STORIES SHALL NOT EXCEED 0.50". b. ALIGNMENT OF WALLS SUPPORTING STRUCTURAL STEEL OR PRECAST FRAMING: 1. FOR HEIGHTS 100 FEET OR LESS: ± 0.75" FROM THEORETICAL PLAN LOCATION. 2. ALIGNMENT DIFFERENCE BETWEEN ADJACENT STORIES SHALL NOT EXCEED 0.50". c. LATERAL ALIGNMENT 1. EDGES OF SLABS ON BEAMS ADJACENT TO STONE OR BRICK VENEER: +0.50", -0.75" 2. EDGES OF SLABS AND BEAMS SUPPORTING STRUCTURAL STEEL OR PRECAST FRAMING: +0.75, -1.00" 3. ALIGNMENT DIFFERENCE BETWEEN EDGES OF ADJACENT STORIES SHALL NOT EXCEED 0.50". d. LEVEL L ALIGNMENT: 1. ELEVATION OF TOP OF SLABS POURED ON METAL DECK. i AT COLUMNS, WALLS AND OTHER VERTICAL SUPPORTS: +0.75", -0.75" FROM SPECIFIED ELEVATION. ii OVER FLOOR FRAMING: SET SCREEDS AND ADJUST AS REQUIRED TO ACHIEVE SPECIFIED UNIFORM SLAB THICKNESS OVER BEAMS, ALLOWING FOR BEAM CAMBER AND DEFLECTION. ADDITIONAL SLAB THICKNESS BETWEEN BEAMS DUE TO DEFLECTION OF METAL DECK IS ACCEPTABLE. Q. CONCRETE PLACEMENT: a. CONSOLIDATE ALL CONCRETE DURING PLACEMENT AND THOROUGHLY WORK AROUND REINFORCING AND EMBEDDED ITEMS AND INTO CORNERS OF FORMS FOLLOWING ACI RECOMMENDATIONS. b. WHEN CONCRETE PLACEMENT IS INTERRUPTED, NOTIFY THE STRUCTURAL ENGINEER FOR RECOMMENDATIONS. UNLESS DIRECTED OTHERWISE, PROVIDE A CONSTRUCTION JOINT BY ROUGHENING THE CONCRETE SURFACE TO AN AMPLITUDE OF 1/4". COAT THE JOINT SURFACE WITH SPECIFIED BONDING AGENT PRIOR TO POURING THE CONCRETE. i. AT ENDS OF BEAMS, SLABS, JOINTS, WALLS AND GRADE BEAMS, TERMINATE TOP REINFORCING WITH STANDARD HOOKS UNLESS SHOWN OTHERWISE ON PLANS OR DETAILS. j. REINFORCING AROUND OPENINGS IN WALLS AND FLOORS: UNLESS NOTED OTHERWISE ON PLAN OR IN DETAILS, PROVIDE 2-#5 BARS (ONE BAR EACH FACE) AT EACH SIDE OF OPENING (CIRCULAR OPENINGS SHALL BE CONSIDERED SQUARE WITH EQUIVALENT OPENING WIDTH EQUAL TO DIAMETER OF CIRCULAR OPENING). EXTEND #5 BARS PAST EDGES OF OPENING A DISTANCE OF 24". EXCEPTIONS: RECTANGULAR OPENINGS WITH THE LARGEST OPENING DIMENSION LESS THAN 8" AND CIRCULAR OPENINGS LESS THAN 8" IN DIAMETER DO NOT NEED ADDITIONAL REINFORCING AS DESCRIBED ABOVE. MULTIPLE OPENINGS SHALL BE SPACED A MINIMUM OF 32" (CLEAR) APART TO QUALIFY FOR THIS EXCEPTION. WHERE UNIFORMLY SPACED WALL OR SLAB REINFORCING IS INTERRUPTED BY THE OPENING, PROVIDE ADDITIONAL REINFORCING AT EACH EDGE EQUAL TO HALF THE AREA OF INTERRUPTED REINFORCING. SIZE OF ADDITIONAL BARS AT EACH EDGE SHALL MATCH THE SIZE OF INTERRUPTED REINFORCING. SPACE THE ADDITIONAL BARS AT 3" ON CENTER STARTING 1" FROM THE SIDE OF THE OPENING AND EXTEND THE BARS PAST THE EDGES OF THE OPENING THE LENGTH OF A CLASS 'B' SPLICE. A. ALL CONCRETE AND MILD REINFORCING MATERIALS USED IN POST-TENSIONED CONCRETE CONSTRUCTION SHALL CONFORM TO REQUIREMENTS GIVEN IN ACI 318, ACI 301 (REFERENCED EDITIONS) AND THE REQUIREMENTS GIVEN IN PARAGRAPH 1 ABOVE. B. THE DESIGN OF CONNECTIONS SHALL BE IN ACCORDANCE WITH ACI 318 AND PCI DESIGN HANDBOOK- PRECAST AND PRESTRESSED CONCRETE. C. THE PRECAST MANUFACTURER SHALL SUPPLY ALL PRECAST MEMBERS NECESSARY TO FULLY CONSTRUCT THE COMPLETED STRUCTURE AS SHOWN IN THE CONTRACT DOCUMENTS. D. THE PRECAST MANUFACTURER SHALL DESIGN ALL PRECAST COMPONENTS AND CONNECTIONS TO ADEQUATELY WITHSTAND AND SUPPORT LOADS, FORCES AND MEMBER WEIGHTS SHOWN IN THE CONTRACT DOCUMENTS. E. THE PRECAST MANUFACTURER SHALL SUPPLY ALL NECESSARY CONNECTION HARDWARE AND ACCESSORIES TO ERECT AND PLACE PRECAST MEMBERS IN THEIR FINAL POSITION AND PROPERLY TRANSFER ALL LOADS FROM THE MEMBERS INTO SUPPORTING ELEMENTS. THE DESIGN OF CONNECTIONS AND SUPPORT OF PRECAST MEMBERS SHALL NOT OVERLOAD NOR CAUSE DISTORTION OF THE SUPPORTING ELEMENTS. F. THE CONTRACTOR AND PRECAST MANUFACTURER SHALL JOINTLY PROVIDE TEMPORARY BRACING OF THE PRECAST STRUCTURE AS REQUIRED TO PROVIDE STRUCTURAL STABILITY UNTIL THE LATERAL LOAD RESISTING SYSTEM IS COMPLETE AND ALL CONNECTIONS ALONG WITH CONCRETE TOPPING (IF ANY) ARE COMPLETED, INSPECTED AND ACCEPTED. G. THE STRUCTURE IS DESIGNED FOR ITS COMPLETED SERVICE CONDITION. THE CONTRACTOR AND PRECAST MANUFACTURER ARE JOINTLY RESPONSIBLE FOR MEMBER DESIGN TO WITHSTAND HANDLING AND ERECTION FORCES. H. THE PRECAST MANUFACTURER SHALL PROVIDE ALL PLATES EMBEDDED IN CAST-IN-PLACE CONCRETE REQUIRED TO SUPPORT AND TRANSFER FORCES FROM PRECAST ELEMENTS. ADDITIONAL EMBED PLATES NECESSARY TO MAINTAIN POSITION AND STABILITY OF PRECAST ELEMENTS SHALL BE PROVIDED BY THE PRECAST MANUFACTURER. ALL WELDING OF HEADED ANCHOR STUDS AND DEFORMED ANCHORS SHALL BE CAPABLE OF DEVELOPING THE STRENGTH OF THE ANCHOR. I. FIRE RATING OF PRECAST ELEMENTS: PROVIDE PRECAST ELEMENTS AND ASSEMBLIES WITH FIRE RESISTIVE RATINGS EQUAL TO THE REQUIREMENTS GIVEN IN PARAGRAPH 5 - BUILDING CONSTRUCTION INFORMATION, PART B. PROTECT STEEL SEATS SUPPORTING PRECAST CONSTRUCTION WITH SPRAY-APPLIED FIRE-RESISTIVE MATERIALS. J. CONNECTIONS FOR ANY PRECAST ELEMENT SUBJECT TO THERMAL EXPANSION AND CONTRACTION SHALL BE DESIGNED TO PROVIDE FOR MOVEMENT OF THE ELEMENT WITHOUT DAMAGE OR DISTRESS TO THE ELEMENT, CONNECTION OR SUPPORTING STRUCTURE. K. PRODUCT MATERIAL REQUIREMENTS: a. PRESTRESS REINFORCING SHALL BE LOW-RELAXATION, 7-WIRE STRAND (GRADE 270) CONFORMING TO THE REQUIREMENTS OF ASTM A416. b. REINFORCING TO BE WELDED SHALL CONFORM TO THE REQUIREMENTS OF ASTM A706, GRADE 60. c. BEARING PADS: 1. DOUBLE TEES: R.O.F. BEARING PADS, SIZE AS REQUIRED (3/8" THICK x4"x0'-6 MINIMUM). 2. BEAMS: COTTON DUCK BEARING PADS, SIZE AS REQUIRED (1/2" THICK MINIMUM). 3. SPANDREL PANELS: COTTON DUCK BEARING PADS, SIZE AS REQUIRED (1/2" THICK MINIMUM). 4. SLABS AND PLANK: 1/8" THICK BY 2" WIDE CONTINUOUS TEMPERED HARDBOARD, KOROLATH OR APPROVED EQUAL 5. ALL R.O.F. PADS SHALL BE MASTICORD OR APPROVED EQUAL L. CONNECTION REQUIREMENTS: a. UNLESS SHOWN OTHERWISE, CONNECT ALL PRECAST FLOOR AND ROOF MEMBERS TO ADJACENT WALLS, BEAMS AND SPANDRELS AT 5'-0 ON CENTER MAXIMUM. MINIMUM CONNECTION CAPACITY SHALL BE 12 KIPS IN SHEAR AND TENSION, ACTING SIMULTANEOUSLY, UNLESS NOTED OTHERWISE. b. PROVIDE STEEL LEVELING ANCHORAGES AT 8'-0 ON CENTER MAXIMUM IN ALL TEE AND SLAB EDGES. ANCHORS IN TEES AND SLABS SHALL BE BROUGHT TOGETHER AND WELDED TO ELIMINATE DIFFERENTIAL CAMBER. c. ALL CONNECTIONS SHALL BE CONCEALED UNLESS SHOWN OTHERWISE OR PERMANENTLY COVERED BY OTHER WORK. d. COAT ALL CONNECTIONS IN CONTACT WITH EARTH WITH BITUMINOUS PAINT. e. COAT ALL FINISHED CONNECTIONS IN GARAGE CONSTRUCTION WITH PRIMER AND HIGH PERFORMANCE PAINT SYSTEM APPROVED BY THE ARCHITECT AND ENGINEER. ALTERNATIVELY, PROVIDE GALVANIZED CONNECTIONS WITH A MINIMUM GALVANIZING THICKNESS OF G90. REPAIR GALVANIZING DAMAGED BY WELDING PER SPECIFICATIONS. f. WELDED CONNECTIONS SHALL BE IN ACCORDANCE WITH AWS D1.1 BY WELDERS CERTIFIED BY THE AWS STANDARD QUALIFICATION TESTS. 2. PRECAST CONCRETE A. PROVIDE POST-INSTALLED, CONCRETE ANCHORS AS SHOWN IN THE CONTRACT DOCUMENTS AND IN THE SPECIFICATIONS. B. ANCHORS SUPPORTING FIRE-RESISTANCE RATED FRAMING (FIRE-PROOFED STRUCTURAL FRAMING), SHALL BE ONE OF THE FOLLOWING AS INDICATED ON PLANS AND DETAILS: a. HILTI HDA UNDERCUT OR KWIK BOLT TZ ANCHORS b. SIMPSON TORQ-CUT OR STRONG-BOLT 2 ANCHORS c. POWERS ATOMIC+ UNDERCUT OR POWER-STUD+ SD1 d. RED HEAD TRUBOLT+ WEDGE ANCHOR BY ITW ANCHOR INSTALLATION SHALL BE INSPECTED IN ACCORDANCE WITH THE REQUIREMENTS FOR SPECIAL INSPECTIONS DESCRIBED IN PARAGRAPH 2, SECTION 01-GENERAL REQUIREMENTS IN THE GENERAL NOTES AND SHALL BE PROTECTED WITH CEMENTITIOUS SPRAY-APPLIED FIRE PROOFING IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. C. ANCHORS SUPPORTING NON-FIREPROOFED STRUCTURAL FRAMING SHALL BE ONE OF THE FOLLOWING AS INDICATED ON PLANS AND DETAILS: a. HILTI HDA UNDERCUT OR KWIK BOLT TZ ANCHORS b. SIMPSON TORQ-CUT OR STRONG-BOLT 2 ANCHORS c. POWERS ATOMIC+ UNDERCUT OR POWER-STUD+ SD1 d. RED HEAD TRUBOLT+ WEDGE ANCHOR BY ITW ANCHOR ISTALLATION SHALL BE INSPECTED IN ACCORDANCE WITH THE REQUIREMENTS FOR SPECIAL INSPECTIONS DESCRIBED IN PARAGRAPH 2, SECTION 01-GENERAL REQUIREMENTS IN THE GENERAL NOTES. D. ANCHORS SUPPORTING MISCELLANEOUS FRAMING SHALL BE AS SHOWN IN THE PLANS AND DETAILS. IF NOT OTHERWISE SPECIFIED, THE ANCHORS SHALL BE ONE OF THE FOLLOWING: a. HILTI KWIK BOLT TZ b. SIMPSON STRONG-BOLT 2 c. POWERS POWER-STUD+ SD1 d. RED HEAD TRUBOLT+ WEDGE ANCHOR BY ITW E. ANCHORS SUPPORTING ARCHITECTURAL COMPONENTS, ELECTRICAL AND MECHANICAL EQUIPMENT SHALL BE ONE OF THE FOLLOWING AS INDICATED ON PLANS AND DETAILS: a. HILTI HDI b. SIMPSON DROP-IN c. POWERS STEEL DROP-IN d. RED HEAD MULTI-SET II DROP IN. F. ANCHORS ATTACHING LIGHT-GAGE STEEL FRAMING TO CONCRETE SHALL BE ONE OF THE FOLLOWING AS INDICATED ON PLANS AND DETAILS: a. HILTI LOW-VELOCITY X-U UNIVERSAL POWDER DRIVEN TRACK FASTENERS b. SIMPSON PDPA POWDER DRIVEN FASTENERS c. POWERS POWDER ACTUATED FASTENERS d. RAMSET TRUE EMBEDMENT (TE) POWER DRIVEN FASTENER G. PRIOR TO ANCHOR INSTALLATION, LOCATE EXISTING REINFORCING WITHIN CONCRETE SUBSTRATE. DO NOT DAMAGE EXISTING REINFORCING DURING INSTALLATION. CONTACT THE STRUCTURAL ENGINEER IF ANCHOR LOCATION CONFLICTS WITH EXISTING REINFORCING. H. PRODUCT SUBSTITUTION: THE CONTRACTOR MAY SUBMIT ALTERNATE ANCHORS FOR REVIEW AND APPROVAL PROVIDED THE ACCOMPANYING PRODUCT DATA IS SATISFACTORY TO THE ENGINEER FOR COMPARISION TO THE SPECIFIED ANCHORS. 3. POST-INSTALLED ANCHORS INTO CONCRETE: A. ALL CONCRETE MASONRY WORK INCLUDING FABRICATION AND PLACEMENT OF REINFORCING SHALL BE PERFORMED IN ACCORDANCE WITH REQUIREMENTS GIVEN IN ACI 530 AND ACI 530.1 (REFERENCED EDITIONS) EXCEPT AS MODIFIED BY THE PROJECT CONTRACT DOCUMENTS. B. MASONRY BLOCK UNITS SHALL CONFORM TO ASTM C90 (LIGHTWEIGHT BLOCK). C. MORTAR USED IN MASONRY CONSTRUCTION SHALL CONFORM TO ASTM C270 AS FOLLOWS: a. EXTERIOR WALLS AND INTERIOR BEARING WALLS: TYPE S b. FOUNDATION WALLS AND WALLS EXPOSED TO EARTH: TYPE M c. INTERIOR, NON-BEARING WALLS: TYPE O (OR TYPE S) D. GROUT USED IN MASONRY CONSTRUCTION SHALL CONFORM TO ASTM C476 AND SHALL DEVELOP PSI (MINIMUM) COMPRESSIVE STRENGTH IN 28-DAYS WHEN TESTED IN ACCORDANCE WITH C1019. E. MASONRY SHALL DEVELOP PSI (MINIMUM) COMPRESSIVE STRENGTH (f'm) IN 28 DAYS WHEN TESTED IN ACCORDANCE WITH PROJECT SPECIFICATIONS. F. ALL REINFORCING STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI AND SHALL MEET THE REQUIREMENTS OF ASTM A615 OR ASTM A706. G. REINFORCING USED IN WELDED APPLICATIONS SHALL CONFORM TO ASTM A706 WITH A MINIMUM YIELD STRENGTH OF 60,000 PSI. H. HORIZONTAL JOINT REINFORCING SHALL CONFORM TO ASTM A951 (LADDER-TYPE) WITH CROSS WIRES AT 16" ON CENTER. SIDE RODS SHALL BE SIZE AND SHALL CONFORM TO ASTM A82. I. STEEL PLATES EMBEDDED IN GROUTED MASONRY SHALL CONFORM TO ASTM A36 UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. HEADED ANCHOR STUDS SHALL CONFORM TO ASTM A108, 60,000 PSI MINIMUM TENSILE STRENGTH. REINFORCING BARS WELDED TO PLATES SHALL CONFORM TO ASTM A706, GRADE 60. J. REINFORCING DETAILING: a. ALL REINFORCING SHALL BE DETAILED IN ACCORDANCE WITH ACI 530 AND ACI 530.1. b. VERTICAL REINFORCING SHALL EXTEND THE FULL HEIGHT OF THE WALL AND SHALL BE GROUTED IN PLACE. c. CONTINUOUS REINFORCING MAY BE SPLICED AS REQUIRED USING BARS OF LONGEST PRACTICAL LENGTH. HORIZONTAL REINFORCING SHALL BE CONTINUOUS AROUND WALL CORNERS AND INTERSECTIONS. d. WHERE REQUIRED, REINFORCING SPLICES SHALL BE SHOWN ON REINFORCING SHOP DRAWINGS AND SHALL CONFORM TO THE FOLLOWING SCHEDULE: 1. CONCRETE MASONRY UNITS: 04-MASONRY 3,000 1,350 #9 A. DEAD LOADS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B. FLOOR LIVE LOADS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C. ROOF LIVE LOADS . . . . . . . . . . . . . . D. RISK CATEGORY (IBC 1604.5) . . . . . . . . . . . . . . . . . . . . E. SNOW LOADS: GROUND SNOW LOAD, P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FLAT ROOF SNOW LOAD, P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SNOW EXPOSURE FACTOR, C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SNOW LOAD IMPORTANCE FACTOR, I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THERMAL FACTOR, C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SEISMIC LOADS: SEISMIC IMPORTANCE FACTOR, I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SITE CLASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SEISMIC DESIGN CATEGORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BASIC SEISMIC FORCE RESISTING SYSTEM(S) . . . . . . . . . . . . DESIGN BASE SHEAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SEISMIC RESPONSE COEFFICIENT, C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RESPONSE MODIFICATION FACTOR, R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANALYSIS PROCEDURE USED . . . . . . . . . . . . . . . . . . F. WIND LOADS: BASIC WIND SPEED (3-SECOND GUST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIND EXPOSURE CATEGORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INTERNAL PRESSURE COEFFICIENT . . . . . . . . . . . . . . . . . . . . . . . . . . g f e s t E S 1 DS D1 S AS SHOWN ON PLANS AS SHOWN ON PLANS SEE SNOW AND WIND LOADS BELOW (20 PSF MINIMUM) II - STANDARD OCCUPANCY 30 PSF 30 PSF 1.0 1.0 1.2 1.0 0.183 0.058 C 0.147 0.066 B ORDINARY PRECAST SHEAR WALLS --- 0.037 4 EQUIVALENT LATERAL FORCE ANALYSIS (ASCE-7 12.8) 126 MPH B ± 0.18 (ENCLOSED) E. ALL CONCRETE IN CONTACT WITH ON-SITE SOILS SHALL CONTAIN TYPE I/II CEMENT. F. ALL REINFORCING STEEL IN CONCRETE SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI AND SHALL MEET THE REQUIREMENTS OF ASTM A615 OR ASTM A706. REINFORCING SHOWN AS GRADE 75 SHALL HAVE A MINIMUM YIELD STRENGTH OF 75,000 PSI AND MEET THE REQUIREMENT OF ASTM A615. G. CONCRETE REINFORCING USED IN WELDED APPLICATIONS SHALL CONFORM TO ASTM A706 WITH A MINIMUM YIELD STRENGTH OF 60,000 PSI. H. MECHANICAL REINFORCING COUPLERS SHALL BE ZAP SCREWLOCK MANUFACTURED BY BARSPLICE PRODUCTS, INC. (ICC REPORT ER-5461) OR APPROVED EQUIVALENT. COUPLERS SHALL BE ZINC COATED WHERE USED IN PARKING STRUCTURES AND STRUCTURES CONTAINING LIQUIDS. COUPLERS SHALL BE CAPABLE OF DEVELOPING 125% OF THE SPECIFIED YIELD STRENGTH OF THE REINFORCING. I. WELDED WIRE FABRIC SHALL BE SUPPLIED IN SHEETS ONLY AND SHALL MEET THE REQUIREMENTS OF ASTM A185. J. STEEL PLATES EMBEDDED IN CONCRETE SHALL CONFORM TO ASTM A36 UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. HEADED ANCHOR STUDS SHALL CONFORM TO ASTM A108, 60,000 PSI MINIMUM TENSILE STRENGTH. REINFORCING BARS WELDED TO PLATES SHALL CONFORM TO ASTM A706, GRADE 60. K. REINFORCING DETAILING: a. ALL REINFORCING SHALL BE DETAILED IN ACCORDANCE WITH ACI 318 AND ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT". b. CONCRETE COVER: UNLESS OTHERWISE SHOWN ON PLANS OR IN DETAILS, PROVIDE THE FOLLOWING CONCRETE COVER TO REINFORCING: 1. CONCRETE POURED AGAINST EARTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. CONCRETE POURED IN FORMS AND EXPOSED TO WEATHER OR EARTH: #5 BARS OR SMALLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BARS LARGER THAN #5 BARS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. COLUMNS, GIRDERS AND BEAMS (PRINCIPAL REINFORCING, TIES AND STIRRUPS). . . . . . 4. SLABS AND WALLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . c. SPLICES OF REINFORCING BARS ARE PERMITTED ONLY AS DETAILED OR AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALL BE CLASS 'B' LAP SPLICES UNLESS NOTED OTHERWISE. d. REINFORCING IN BEAMS, SLABS, WALLS AND GRADE BEAMS NOTED AS CONTINUOUS SHALL BE LAP SPLICED WITH CLASS 'B' LAP SPLICES AS FOLLOWS: 1. TOP REINFORCING BARS - AT MIDSPAN 2. BOTTOM REINFORCING BARS - OVER SUPPORTS e. SPLICE WIRE FABRIC REINFORCING BY LAP SPLICING ONE FULL MESH PLUS 2" AT SIDE AND END LAPS, BUT NOT LESS THAN 6" . LAP SPLICES SHALL BE WIRE TIED. f. MAKE ALL REINFORCING BARS CONTINUOUS AROUND CORNERS OR PROVIDE CORNER BARS OF EQUAL SIZE AND SPACING. SEE DETAILS FOR REINFORCING AT WALL INTERSECTIONS AND CORNERS. SPLICE CORNER BARS WITH CLASS 'B' LAP SPLICES UNLESS SHOWN OTHERWISE. g. AT LOCATIONS WHERE ALL REINFORCING WITHIN A STRUCTURAL ELEMENT WILL BE SPLICED, THE SPLICES MUST BE STAGGERED UNLESS SHOWN OTHERWISE IN DETAILS OR SCHEDULES. OTHERWISE, STAGGER ADJACENT SPLICES WHERE POSSIBLE. h. REINFORCING BAR DEVELOPMENT AND LAP SPLICE LENGTHS: REFER TO DEVELOPMENT LENGTH AND LAP SPLICE SCHEDULE SHOWN BELOW FOR MINIMUM SPLICE AND DEVELOPMENT LENGTHS TO BE USED FOR DETAILING. MASONRY LAP SPLICE SCHEDULE BAR CENTERED IN CELL BAR SIZE 6" BLOCK 8" BLOCK 10" AND 12" BLOCK ALL BLOCK SIZES BAR AT EDGE OF CELL 22 16 54 34 64 NOTES: 1. VALUES APPLY ONLY FOR MASONRY COMPRESSIVE STRENGTH (f'm) OF 1,350 PSI. 2. LAP LENGTHS IN TABLE ABOVE ARE GIVEN IN INCHES. 3. VALUES ONLY APPLY WHEN A SINGLE BAR IS WITHIN CELL. 4. PROVIDE MECHANICAL SPLICES FOR #8 BARS AND LARGER. 7 6 4 5 3 64 52 50 22 28 16 46 22 28 16 64 54 32 45 18 e. VERTICAL REINFORCING SHALL BE DOWELED INTO FOUNDATION OR SLAB SUPPORTING MASONRY. PROVIDE DOWELS OF ADEQUATE LENGTH FOR DEVELOPMENT LENGTH INTO FOUNDATION AND LAP SPLICE PROJECTION ABOVE. FOR MASONRY SUPPORTED ON SLABS, PROVIDE DOWELS EMBEDDED INTO SLAB WITH STANDARD HOOKS. DOWEL SIZE AND SPACING SHALL MATCH VERTICAL REINFORCING. K. MINIMUM WALL REINFORCING: a. REINFORCE MASONRY WALLS AS SHOWN ON THE DRAWINGS. WHERE NOT SHOWN, REINFORCE WALLS (INCLUDING PARTITION WALLS) WITH #5 VERTICAL BARS AT 48" ON CENTER MAXIMUM SPACING. b. PROVIDE 1-#5 BAR AT ALL CORNERS, ENDS OF WALLS, EACH SIDE OF OPENINGS AND EACH SIDE OF CONTROL JOINTS. c. PROVIDE HORIZONTAL JOINT LADDER-TYPE REINFORCING AT 16" ON CENTER UNLESS NOTED OTHERWISE ON DRAWINGS. PROVIDE PREFABRICATED JOINT REINFORCING ASSEMBLIES FOR CORNERS AND INTERSECTIONS. LAP SPLICE JOINT REINFORCING 8" KEEPING CELL OPENING CLEAR OF CROSS WIRES. d. PROVIDE ADDITIONAL HORIZONTAL JOINT REINFORCING IN BED JOINT ONE MASONRY COURSE ABOVE OPENINGS. EXTEND JOINT REINFORCING A MINIMUM OF 2'-6" PAST EDGE OF OPENINGS. e. PROVIDE BOND BEAMS IN MASONRY WALLS AS SHOWN ON THE DRAWINGS. WHERE NOT SHOWN, PROVIDE BOND BEAMS WITH 2-#5 BARS AS FOLLOWS: 1. AT TOP COURSE OF PARAPETS, 2. IN ONE OF THE UPPER THREE COURSES OF ALL WALLS, 3. UNLESS SHOWN OTHERWISE IN LINTEL SCHEDULE, OVER THE TOP OF ALL OPENINGS GREATER THAN 24" WIDE, EXTENDING 2'-6 PAST EDGE OF OPENING. L. OPENINGS IN WALLS: a. REFER TO ARCHITECTURAL, MECHANICAL AND PLUMBING DRAWINGS FOR LOCATIONS OF OPENINGS THROUGH MASONRY WALLS. PROVIDE LOOSE LINTEL OR BOND BEAM OVER TOP OF OPENINGS GREATER THAN 24" WIDE. M. REINFORCING PLACEMENT: a. ALL REINFORCING SHALL HAVE A MINIMUM GROUT COVER OF ONE BAR DIAMETER. b. BARS CENTERED IN CELLS SHALL BE HELD SECURELY IN PLACE. BARS NOTED AS "EACH FACE" SHALL BE SECURED IN PLACE AT 4'-0 ON CENTER (VERTICAL) USING PREFABRICATED REBAR POSITIONERS. N. CONTROL JOINTS: a. UNLESS SHOWN OTHERWISE ON STRUCTURAL OR ARCHITECTURAL DRAWINGS, PROVIDE CONTROL b. JOINTS AT A MAXIMUM SPACING OF 30'-0 ON CENTER IN EXTERIOR WALLS AND 40'-0 ON CENTER IN INTERIOR WALLS. O. GROUTING: a. FILL ALL BLOCK CELLS CONTAINING REINFORCING WITH GROUT. b. FILL ALL VOIDS AND CELLS WITH GROUT FOR A DISTANCE OF 24" BELOW AND 16" EACH SIDE OF ALL BEAM AND LINTEL REACTIONS OR OTHER CONCENTRATED LOADS UNLESS SHOWN OTHERWISE. c. FILL ALL VOIDS AND CELLS OF MASONRY BLOCK SUPPORTING SLABS OR STEEL DECK FOR A DISTANCE OF 8" BELOW BEARING ELEVATION. d. UNLESS SHOWN OTHERWISE IN DETAILS, GROUT CELLS CONTAINING ANCHORS OR EMBEDMENTS PLUS ADJACENT CELLS BELOW, ABOVE AND EACH SIDE. e. FILL ALL CELLS BELOW GRADE WITH GROUT. f. FILL ALL CELLS ABOVE ROOF LEVEL WITH GROUT AT PARAPETS. g. WHERE A CHANGE IN WALL THICKNESS OCCURS, GROUT THE TOP COURSE OF THE THICKER WALL. h. GROUT BEAM AND JOIST POCKETS WHERE REQUIRED TO MAINTAIN FIRE RATING OF WALL. P. SLIP JOINTS: PROVIDE SLIP JOINTS AT THE TOP OF ALL NON-LOAD BEARING WALLS. UNLESS SHOWN OTHERWISE ON DRAWINGS, BRACE TOP OF WALLS TO STRUCTURE ABOVE USING L4x4x1/4" BY 12" LONG EACH SIDE OF WALL AT 8'-0 ON CENTER. ATTACH ANGLES DIRECTLY TO FRAMING ABOVE, OR USE L3x3x1/4" ANGLE FRAMING AS HANGERS AND KICKERS AS REQUIRED TO SUSPEND L4x4x1/4 FROM FRAMING ABOVE. Q. MAINTAIN SUPPORT OF MASONRY LINTELS FOR A MINIMUM OF SEVEN DAYS OR UNTIL MASONRY HAS REACHED STRENGTH SUFFICIENT TO SAFELY SUPPORT IMPOSED LOADS. R. MASONRY WALL CONSTRUCTION SHALL BE RUNNING BOND UNLESS NOTED OTHERWISE ON THE DRAWINGS. PRECAST CONCRETE NW 5,000 S1 3" 1 1/2" 2" 1 1/2" 3/4" 35,000 PSF 2,500 PSF 2,500 PSF N.A. 35 N.A. 0.01 N.A. 0.004 100 60 2,000 30 60 800 M. COMPOSITE CONCRETE TOPPING: a. PRECAST SURFACES RECEIVING CONCRETE TOPPINGS SHALL BE ROUGHED (RAKED FINISH) FOR PROPER BOND PER ACI 318. b. MINIMUM CONCRETE TOPPING THICKNESS IS GIVEN IN DRAWING PLAN NOTES. ADDITIONAL TOPPING MAY BE REQUIRED AT ENDS OF MEMBERS DUE TO MEMBER CAMBER AND/OR WASHES FOR WATER DRAINAGE IN PARKING GARAGES. c. REINFORCING IN TOPPING AROUND OPENINGS: PROVIDE 1-#5 BAR AT EACH SIDE OF OPENING. BARS SHALL EXTEND 24" BEYOND OPENING EDGES. N. ERECTION AND HANDLING OF PRECAST MEMBERS SHALL BE ACCOMPLISHED IN SUCH A MANNER AS TO ASSURE THAT NO SECTIONS ARE OVERSTRESSED OR CHIPPED. STRUCTURAL GENERAL NOTES 24.1 PSF 66.7 PSF 24.1 PSF 95.0 PSF 41.1 PSF 44.0 PSF 41.1 PSF 51.3 PSF Consulting Engineers 4582 S. Ulster St. Pkwy., Ste. 750 Denver, CO 80237-2639 303-741-3737 M I R O S. A. MIRO, INC. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2015 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 OWNER MCWHINNEY 2725 ROCKY MOUNTAIN AVE STE 200 LOVELAND, CO 80538 t: 970.962.9990 DEVELOPER SAGE HOSPITALITY 1575 WELTON STREET STE 300 DENVER, CO 80202 t: 303.595.7200 f: 303.595.7219 OPERATOR SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 1 GMP / PERMIT SET 13 MAY 2016 5/12/2016 10:07:21 PM S-001 STRUCTURAL GENERAL NOTES 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE DOWNTOWN FORT COLLINS PARKING GARAGE _Sheet List Sheet Number Sheet Name PERMIT 100% CD S-000 COVER • S-001 STRUCTURAL GENERAL NOTES • S-002 STRUCTURAL GENERAL NOTES • S-003 STRUCTURAL GENERAL NOTES • S-101 FOUNDATION PLAN • S-102 LEVEL 2 FRAMING PLAN • S-103 LEVEL 3 FRAMING PLAN • S-103.5 LEVEL 3.5 FRAMING PLAN • S-201 FOUNDATION DETAILS • S-202 FOUNDATION DETAILS • S-203 FOUNDATION DETAILS • S-301 PRECAST GARAGE DETAILS • S-302 PRECAST GARAGE DETAILS • S-310 FRAMING DETAILS • S-401 STAIR TOWER PLANS • S-411 RAMP WALL ELEVATIONS • BENT STL. PL. RISER PTD (TYP.) BENT STL. PL. TREAD PTD (TYP.) 1'-0" CONCRETE FILLED STL PAN TREAD (TYP.) STEEL CHANNEL STRINGER, PTD, (TYP.) CONCRETE ON MTL DECKING PTD CLOSURE PLATE, GRIND WELDS SMOOTH CONT.PTD STEEL CHANNEL AT STAIR LANDING PERIMETER (TYP) PAINT EXPOSED STL RISER (TYP.) EXPOSED STRUCTURAL STEEL @ LANDING PTD, (TYP.) CONT. SEALANT @ JOINT, TYP STEEL PLATE, PTD. (TYP.) RE: FINISH SCHEDULE 2 1/2" 1-1/2" STD STL PIPE PTD 1-1/2" TUBE STL SUPPORT PLACED AT EACH END OF GUARDRAIL LENGTH & CENTER. RE: ROOM FINISH SCHEDULE FINISH OF STL HANDRAIL AND SUPPORT BRACKET TO BE RAW STEEL W/CLEAR SEALER, UNO. PTD 1/2" STL ROD PICKETS RE: ROOM FINISH SCHEDULE 3/4" 3/4" 1 1/2" MIN 1 1/2" 1 1/2" 4 1/2" MAX ALIGN 2" MIN 1 1/2" 1 1/2" 3/4" 3/4" RE: SHEET NOTE 2 1/2" LINE OF FLOOR OR NOSING AS APPLIES 1/4" THICK 2" DIA STL PLATE BRACKET MOUNTING PLATE - FULLY WELD TO BRACKET ARM. GRIND WELDS SMOOTH (TYP) 1/2" OD STL BAR HANDRAIL SUPPORT SPACE BRACKETS AT 4'-0" O.C. MAX, TYP. (UNO) 1-1/2" STD STL PIPE ANCHOR TO CONCRETE WALL OR ATTACH DIRECTLY TO STUDS OR BLOCKING AT METAL FRAMING FACE OF WALL FINISH OF STL HANDRAIL AND SUPPORT BRACKET TO BE RAW STEEL W/CLEAR SEALER, UNO. 4 - 1/2" MAX PTD 1-1/2" O.D. STL RAIL. RE: ROOM FINISH SCHEDULE PTD 1/2" STL ROD PICKETS. RE: ROOM FINISH SCHEDULE PTD 1-1/2" O.D. RAW TUBE STL RAILS W/ CLEAR SEALER, UNO. PTD 1-1/2" O.D. TUBE STL RAILS. RE: ROOM FINISH SCHEDULE PTD STEEL CHANNEL STRINGER; PAINT ALL EXPOSED STEEL, TOP & BOTTOM 3' - 6" MIN 3' - 0" 3 7/8" MAX 3 7/8" MAX 3'-0" 11" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:49 AM A703 STAIR DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1TYPICAL SCALE: 1 1/2" = 1'-STAIR 0" @ LANDING 2TYPICAL SCALE: 1 1/2" = 1'-GAURDRAIL 0" 3TYPICAL SCALE: 3" = 1'-0" STAIR TREAD 4TYPICAL SCALE: 3" = 1'-0" STAIR TREAD @ TOP STAIR LANDING 5TYPICAL SCALE: 6" = 1'-0" STRINGER MOUNTED HANDRAIL 6TYPICAL SCALE: 6" = 1'-0" WALL MOUNTED HANDRAIL 1 GMP / PERMIT SET 13 MAY 2016 7TYPICAL SCALE: 1 1/2" = 1'-STAIR 0" @ RETURN 11 EQ RISERS = 5' - 10 7/8" 12 EQ RISERS = 3' - 3 1/2" 5' - 9 5/8" A703 1 A703 3 A703 4 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 9:47:05 AM A702 STAIR TOWER PLANS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1NE SCALE: STAIR 1/4" = 1'-0" TOWER AT LEVEL 01 2NE SCALE: STAIR 1/4" = 1'-0" TOWER AT LEVEL 02 3NE SCALE: STAIR 1/4" = 1'-0" TOWER AT LEVEL 03 4NE SCALE: STAIR 1/4" = 1'-0" SECTION 1 GMP / PERMIT SET 13 MAY 2016 11' - 0 1/2" CLR. 6" 6' - 0" 6" EDGE OF SLAB 8" EDGE OF SLAB STANDPIPE LOCATION 7'-6" CLR. ELEV. FUTURE RETAIL 24"X24"X24" SUMP PIT LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" F 5 F.6 G A701 1 A701 2 A701 3 A701 9 EQUAL RISERS 5' - 7 5/8" 10 EQUAL RISERS 5' - 0 3/8" 11 EQUAL RISERS 6' - 6 1/2" 11 EQUAL RISERS 2' - 6" 5' - 11 1/2" A703 1 A703 3 A703 4 24"X24"X24" SUMP PIT, BEYOND PIT DEPTH 5'-0" LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 3.7 4 A701 1 A701 2 A701 3 A701 WS-3 5' - 11" 1' - 0" 4 TREADS @ 11" = 11" 3' - 8 1/8" 5 RISERS @ 6"= 2' - 6" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:47 AM A701 STAIR TOWER PLANS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 2SW SCALE: STAIR 1/4" = 1'-0" TOWER @ LEVEL 02 3SW SCALE: STAIR 1/4" = 1'-0" TOWER @ LEVEL 03 1SW SCALE: STAIR 1/4" = 1'-0" TOWER @ LEVEL 01 4SW SCALE: STAIR 1/4" = 1'-0" SECTION 5SW SCALE: ELEVATOR 1/4" = 1'-0" SECTION 1 GMP / PERMIT SET 13 MAY 2016 1/2" MIN. LIPPED BRICK ALIGN B.O. BRICK W/ B.O. STEEL ANGLE, TYP. 07 65 00.0 FLEXIBLE FLASHING 04 20 00.e WEEP HOLES SLOPE OUT OF WALL @ 24" O.C. LAP OVER FLEXIBLE FLASHING 4" MIN. BEHIND INSULATION 07 25 00.a WEATHER/AIR BARRIER 04 20 00.g MORTAR NET 09 22 00.0 STUCCO SYSTEM 09 22 00.j CASING BEAD W/WEEPS SIM. WS-2 09 22 00.j CASING BEAD W/WEEPS CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a 03 40 00.a PRECAST CONCRETE PANEL SIM. WS-1A SIM. WS-1B SLOPE - 1/4" : 1'-0" 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT 05 12 00.e STEEL ANGLE, RE: STRUCT. 07 65 00.0 FLEXIBLE FLASHING 04 20 00.e WEEP HOLES 07 25 00.a WEATHER/AIR BARRIER 1/2" MIN. LIPPED BRICK ALIGN B.O. BRICK W/ B.O. STEEL ANGLE, TYP. SLOPE OUT OF WALL @ 24" O.C. ABOVE GRADE 04 20 00.g MORTAR NET LAP OVER FLEXIBLE FLASHING 4" MIN BEHIND INSUL. 1/2" TYP. DRIP KERF 07 65 00.0 FLEXIBLE FLASHING 03 45 00.b PRECAST CONCRETE WALL CAP 07 54 00.c TPO BONDING ADHESIVE 07 54 00.d TPO MEMBRANE CONTINUE OVER ROOF EDGE & TURN DOWN WALL 09 21 16.p 1/2" FRT PLY WOOD SHEATHING AND ANCHOR WS-3 1/2" TYP. 07 54 00.e COVER BOARD 07 54 00.d TPO MEMBRANE 07 54 00.g WELD SPLICE 07 54 00.c TPO BONDING ADHESIVE 07 21 00.a 1-1/2" BOARD INSULATION 8" 07 92 00.b CONT. SEALANT 07 54 00.f SEAM PLATE W/ FASTENTER 03 40 00.a PRECAST CONCRETE PANEL 07 62 00.t PREFINISHED METAL COUNTERFLASHING 05 31 23.0 STEEL ROOF DECK, RE: STRUCT. 05 12 00.J STRUCTURAL STEEL 3X2 ANGLE TO RUN WIDTH OF BRICK PILASTER - PAINT TO MATCH PRECAST ABOVE 1" MIN. MAINTAIN CLEAR SPACE FOR PRECAST DEFLECTION 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:44 AM A606 SECTION DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1BRICK SCALE: 3" = 1'-TO 0" STUCCO SILL 2CHANNEL SCALE: 3" = 1'-0" AT STUCCO 3METAL SCALE: 3" = 1'-INSERT 0" 8PRECAST SCALE: 6" = 1'-0" PANEL REVEAL 4ACCENT SCALE: 3" = 1'-0" BRICK AT RETAIL 5CHANNEL SCALE: 3" = 1'-0" AT BRICK 6STUCCO SCALE: 3" = 1'-0" AT PRECAST 7BRICK SCALE: 3" = 1'-PARAPET 0" 9METAL SCALE: 3" = 1'-PANEL 0" REVEAL 1 GMP / PERMIT SET 13 MAY 2016 10RETAIL SCALE: 3" = 1'-0" ROOF AT PRECAST 11BRICK SCALE: 3" = 1'-HEAD 0" AT PRECAST 1 1/2" AIR SPACE WS-1B 04 20 00.g MORTAR NET 07 25 00.a WEATHER/AIR BARRIER LAP OVER FLEXIBLE FLASHING 4" MIN BEHIND INSUL. F.O. STUD 3" LEVEL 02 115' - 0" 08 43 13.d STOREFRONT TYPICAL MULLION 05 12 00.d STEEL BEAM, RE: STRUCT. 05 12 00.e STEEL ANGLE, RE: STRUCT. 08 43 13.a STOREFRONT HEAD CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a EXTRUDED ALUM SILL W/ BACK AND END DAMS, SET IN BED OF SEALANT 08 43 13.c STAIR LANDING, RE. STRUCT. 1/2" 6 1/2" 07 92 00.b CONT. SEALANT 07 62 00.o GALV. COPING CAP 06 10 00.a BLOCKING AS REQ'D 07 65 00.0 FLEXIBLE FLASHING 07 42 13.c INTERLOCKING METAL WALL FLASHING W-3 07 54 00.d TPO MEMBRANE CONTINUE OVER ROOF EDGE & TURN DOWN WALL WS-1B 1 1/2" AIR SPACE 1/2" TYP. F.O. STUD 3" 09 21 16.p 1/2" FRT PLY WOOD SHEATHING 08 43 13.m NON-EXPANDING SPRAY FOAM INSULATION 08 43 13.b STOREFRONT SILL EXTRUDED ALUM SILL W/ BACK AND END DAMS, SET IN BED OF SEALANT 08 43 13.c 07 92 00.b CONT. SEALANT 07 65 00.0 FLEXIBLE FLASHING 05 12 00.e STEEL ANGLE, RE: STRUCT. 04 20 00.g MORTAR NET 07 25 00.a WEATHER/AIR BARRIER 07 65 00.0 FLEXIBLE FLASHING 04 20 00.e WEEP HOLES CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a WS-1A LAP OVER FLEXIBLE FLASHING 4" MIN BEHIND INSUL. SLOPE OUT OF WALL @ 24" O.C. ABOVE GRADE 1/2" MIN. LIPPED BRICK WS-2 ALIGN B.O. BRICK W/ B.O. STEEL ANGLE, TYP. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:41 AM A605 SECTION DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1CANOPY SCALE: 3" = 1'-0" AT STOREFRONT 2STOREFRONT SCALE: 3" = 1'-0" AT STRUCTURE 3STOREFRONT SCALE: 3" = 1'-0" PARPET 7STOREFRONT SCALE: 3" = 1'-0" HEAD AT RETAIL DETAIL 4STOREFRONT SCALE: 3" = 1'-0" AT UPPER FLOORS 5PARAPET SCALE: 3" = 1'-0" AT METAL PANEL 6STOREFRONT SCALE: 3" = 1'-0" SILL AT RETAIL 8STUCCO SCALE: 3" = 1'-0" TO BRICK 1 GMP / PERMIT SET 13 MAY 2016 SIM. DRIP KERF 1/2" TYP. MAINTAIN CLEAR SPACE FOR PRECAST DEFLECTION 03 40 00.a PRECAST CONCRETE PANEL 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT AND ANCHOR - SLOPE 1/4" PER FOOT, TYP. 05 12 00.d STEEL BEAM, RE: STRUCT. 05 31 23.0 STEEL ROOF DECK, RE: STRUCT. 1/2" A606 10 3x2x8 ANGLE AT 48" O.C. MAINTAIN CLEAR SPACE FOR PRECAST DEFLECTION WS-1A A606 7 SIM. 03 40 00.a PRECAST CONCRETE PANEL 03 45 00.b PRECAST CONCRETE WALL CAP 07 54 00.d TPO MEMBRANE 04 20 00.l CONCRETE MASONRY UNIT 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:40 AM A604 SECTION DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1GARAGE SCALE: 1 1/2" = 1'-0" ENTRY AT CANOPY 2GARAGE SCALE: 1 1/2" = 1'-0" ENTRY AT PARAPET 3CHANNEL SCALE: 1 1/2" = 1'-0" AT RETAIL 4PARAPET SCALE: 1 1/2" = 1'-0" AT RETAIL CORNER 5BRICK SCALE: 1 1/2" PARAPET = 1'-0" AT RETAIL 1 GMP / PERMIT SET 13 MAY 2016 ELEVATOR SHAFT INTERIOR PRECAST CONCRETE PANEL 03 40 00.a 03 30 00.c CONC. WALL, RE: STRUCT EXPANSION JOINT 03 30 00.h INTERLOCKING METAL WALL PANEL FASTENERS 07 42 13.b WEATHER/AIR BARRIER 07 25 00.a 1" WS-3 07 42 13.b INTERLOCKING METAL WALL PANEL FASTENERS 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT 03 40 00.a PRECAST CONCRETE PANEL ELEVATOR SHAFT INTERIOR EXTERIOR GARAGE INTERIOR WS-3 SIM. ELEVATOR CONTROL ROOM CONT. GALV STEEL PLATE FIN BELOW 03 30 00.h EXPANSION JOINT 03 30 00.c CONC. WALL, RE: STRUCT 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT 1 1/2" AIR SPACE 4" @ SIM. 3 1/8" 3/8" W-1B W-1A 1" AIR SPACE 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT 1" TYP. WS-1B PRECAST CONCRETE PANEL 03 40 00.a CONT. GALV. STEEL PLATE FIN BELOW CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a WEATHER/AIR BARRIER 07 25 00.a 07 92 00.b CONT. SEALANT 05 12 00.c STEEL COLUMN; RE: STRUCT. .080" ALUMNINUM BRAKE METAL BY STOREFRONT MFR TO MATCH STOREFRONT MULLIONS 08 43 13.f STOREFRONT JAMB 4" .080" ALUMNINUM BRAKE METAL BY STOREFRONT MFR TO MATCH STOREFRONT MULLIONS 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:39 AM A603 PLAN DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 2METAL SCALE: 3" = 1'-PANEL 0" AT STOREFRONT 1METAL SCALE: 3" = 1'-PANEL 0" AT STOREFRONT @ LEVEL 01 3BRICK SCALE: 3" = 1'-AT 0" CONCRETE STEM WALL 4BRICK SCALE: 3" = 1'-AT 0" PLASTER 5ELEV SCALE: 3" = CORE 1'-0" @ LEVEL 01 6ELEVATOR SCALE: 3" = 1'-0" CORE @ LEVEL 02 7ELEVATOR SCALE: 3" = 1'-0" CORE @ LEVEL 03 9RETAIL SCALE: 3" = 1'-0" BRICK AT BRICK 8BRICK SCALE: 3" = 1'-AT 0" PRECAST 1 GMP / PERMIT SET 13 MAY 2016 10STOREFRONT SCALE: 3" = 1'-0" JAMB @ COLUMN TOP OF WALLS BELOW 1 1/2" AIRSPACE 1 1/2" AIRSPACE 3.7 G A511 3 SIM. 08 43 13.g CORNER STOREFRONT MULLION 05 12 00.c STEEL COLUMN; RE: STRUCT. 05 12 00.d STEEL BEAM, RE: STRUCT. 03 40 00.a PRECAST CONCRETE PANEL 05 51 00.a METAL STAIRS CONCRETE STEM WALL BELOW CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a 08 43 13.d STOREFRONT TYPICAL MULLION SIM. WS-3 03 30 00.m CONC. COLUMN, RE: STRUCT 07 92 00.a CONT. CLOSED CELL BACKER ROD AND SEALANT BOTH SIDES CONCRETE STEM WALL BELOW 03 30 00.c CONC. WALL, RE: STRUCT CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a BOTH SIDES, TYP. ALIGN INTERIOR FACE OF STOREFRONT WITH INTERIOR FACE OF CONCRETE STEM WALL 08 43 13.d STOREFRONT TYPICAL MULLION 03 40 00.a PRECAST CONCRETE PANEL WS-3 WS-3 03 30 00.c CONC. WALL, RE: STRUCT CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a 05 12 00.c STEEL COLUMN; RE: STRUCT. 08 43 13.g CORNER STOREFRONT MULLION CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a A511 3 SIM. 1/2" WS-3 TOP OF CONCRETE WALL BELOW 3.7 G TOP OF CMU WALL BELOW TOP OF CONCRETE COLUMN BELOW TOP OF PRECAST SPANDREL BELOW TOP OF METAL SCREEN FRAME BELOW 05 12 00.c STEEL COLUMN; RE: STRUCT. 05 12 00.d STEEL BEAM, RE: STRUCT. 05 51 00.a METAL STAIRS 08 43 13.g CORNER STOREFRONT MULLION STOREFRONT MULLION EXTENSION BELOW 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:38 AM A602 PLAN DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1BRICK SCALE: 1 1/2" PILASTER = 1'-0" @ LEVEL 01 2BRICK SCALE: 1 1/2" PILASTER = 1'-0" @ BRICK INSET 3ENTRY SCALE: 1 1/2" = PILASTER 1'-0" @ LEVEL 02 4STOREFRONT SCALE: 1 1/2" = 1'-0" CORNER AT SW STAIR @ LEVEL 02 6CURTAIN SCALE: 1 1/2" = 1'-0" WALL AT NE STAIR TOWER 7STOREFRONT SCALE: 1 1/2" = 1'-0" RETURN AT NE STAIR 5STOREFRONT SCALE: 1 1/2" = 1'-0" CORNER AT SW STAIR @ ROOF 1 GMP / PERMIT SET 13 MAY 2016 03 30 00.h EXPANSION JOINT EXT. SLAB ON GRADE, ELEV. VARIES, RE. CIVIL WS-3 07 25 00.a WEATHER/AIR BARRIER 07 62 00.a PREFINISHED METAL FLASHING 8" 4" 04 20 00.g MORTAR NET 07 25 00.a WEATHER/AIR BARRIER 07 65 00.0 FLEXIBLE FLASHING 04 20 00.e WEEP HOLES 07 11 13.a DAMPPROOFING 07 25 00.c VAPOR RETARDER 03 30 00.h EXPANSION JOINT 04 20 00.d MASONRY ANCHORAGE LAP OVER FLEXIBLE FLASHING 4" MIN BEHIND INSUL. SLOPE GROUT FOR POSITIVE DRAINAGE, TYP. SLOPE OUT OF WALL @ 24" O.C. ABOVE GRADE 03 30 00.h EXPANSION JOINT EXT. SLAB ON GRADE, ELEVATION VARIES, RE: CIVIL CONT. CLOSED CELL BACKER ROD AND SEALANT 07 92 00.a 1/4" FIBER REINFORCED ASPHALTIC MEMBRANE 07 54 00.h 04 20 00.j DRAINAGE BOARD WS-1A EXTEND UP WALL 8" MIN. ABOVE GRADE EXTEND UP WALL UNDER FLASHING 4" MIN 1" AIR SPACE BRICK WALL BEYOND MCNICOLS WELDED GALV. BAR GRATING 4" X 2" X 1/8" TUBE GALV. STEEL FRAME 1.5"x2"x1/4" GALV. ANGLE TO RUN LENGTH OF GRATING 09 22 00.j CASING BEAD W/WEEPS 07 62 00.a PREFINISHED METAL FLASHING 07 65 00.0 FLEXIBLE FLASHING 07 25 00.a WEATHER/AIR BARRIER LAP OVER FLEXIBLE FLASHING 4" MIN. BEHIND INSULATION 07 92 00.b CONT. SEALANT 07 21 00.f FOUNDATION INSULATION BOARD 07 11 13.a DAMPPROOFING 07 25 00.c VAPOR RETARDER 03 30 00.h EXPANSION JOINT 1" ABOVE GRADE 4" MIN. WS-2 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:36 AM A601 FOUNDATION DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1FOUNDATION SCALE: 3" = 1'-0" DETAIL AT STOREFRONT 2FOUNDATION SCALE: 3" = 1'-0" AT RETAIL STOREFRONT 3FOUNDATION SCALE: 3" = 1'-0" DETAIL AT ELEVATOR CORE 4FOUNDATION SCALE: 3" = 1'-0" AT BRICK LEDGE 5FOUNDATION SCALE: 3" = 1'-0" DETAIL AT STUCCO 1 GMP / PERMIT SET 13 MAY 2016 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: 1/4" = 1'-0" DOOR TYPES DOOR SCHEDULE DOOR # FIRE RATING DOOR FRAME DETAILS TYPE WIDTH HEIGHT THICKNESS MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB THRESHOLD HDW COMMENTS 1 D 3' - 0" 7' - 6" 2" ALUM & GL . STOREFRONT ENTRANCE 2 19' - 0" 8' - 10 1/2" . OVERHEAD DOOR 3 D 3' - 7 1/2" 8' - 9" 2" ALUM & GL . STOREFRONT ENTRANCE 4 D 3' - 7 1/2" 8' - 7" 2" ALUM & GL . STOREFRONT ENTRANCE 5 18' - 0 1/2" 8' - 6 1/2" . OVERHEAD DOOR 6 D 3' - 7 1/2" 8' - 0" 2" ALUM & GL . STOREFRONT ENTRANCE 7 18' - 0 1/2" 8' - 6 1/2" . OVERHEAD DOOR 8 A 3' - 0" 7' - 0" 2" HM . 9 A 3' - 0" 7' - 0" 2" HM . 10 B 5' - 0" 7' - 0" 2" HM . 11 A 3' - 0" 7' - 0" 2" HM . 12 D 3' - 0" 7' - 6 1/2" 2" ALUM & GL . STOREFRONT ENTRANCE 13 A 3' - 0" 7' - 0" 2" HM . 14 C 5' - 8" 7' - 0" 2" ALUM & GL . 15 A 3' - 0" 7' - 0" 2" HM . 17 A 3' - 0" 7' - 0" 2" HM . SCALE: 1/4" = 1'-0" SECTIONAL OVERHEAD DOORS 1 GMP / PERMIT SET 13 MAY 2016 1" 2'-3 1/2" 1" 3'-4" 1'-6" 8'-0" 1'-3" 9'-3" 1" 1" 2'-3 1/2" 1" 1'-3" 4'-8" 1'-4" 10'-3" 1'-3" 9'-2" 1" 2'-3 1/2" 1" 3'-0" 1'-4" 10'-3" 1'-3" 9'-2" 1'-3" 1" 2'-3 1/2" 1" 10'-3" 1'-3" 9'-2" 1'-3" 4"x3/8" HORIZONTAL GALV. STEEL FIN - REFER ELEVATIONS FOR LOCATIONS 2"x3"x1/4" GALV. BENT PLATE - MECHANICALLY FASTENED TO HORIZONTAL FIN AT 48" O.C. STEEL EMBED PLATE METAL SCREEN BEYOND STEEL EMBED PLATE MCNICOLS WELDED GALV. BAR GRATING WITH SADDLE CLIP AT 24" SPACING 4" X 2" X 1/4" GALV. STEEL ANGLE FRAME 4"x3/8" HORIZONTAL GALV. STEEL FIN - REFER ELEVATIONS FOR LOCATIONS 03 40 00.a PRECAST CONCRETE PANEL 1.5"x2"x1/4" GALV. STEEL ANGLE TO RUN LENGTH OF GRATING BOLT HEAD WELDED TO TUBE STEEL FRAME FOR ATTACHEMENT 1/2" 1" STEEL EMBED PLATE MCNICOLS WELDED GALV. BAR GRATING WITH SADDLE CLIP AT 24" SPACING 2" X 4" X 1/4" GALV. STEEL PLATE 4" X 2" X 1/4" GALV. STEEL ANGLE FRAME 6" X 2" X 1/4" GALV. STEEL ANGLE FRAME AT SIM. CONDITION 4"x3/8" HORIZONTAL GALV. STEEL FIN - REFER ELEVATIONS FOR LOCATIONS 03 40 00.a PRECAST CONCRETE PANEL 1.5"x2"x1/4" GALV. STEEL ANGLE TO RUN LENGTH OF GRATING BOLT HEAD WELDED TO TUBE STEEL FRAME FOR ATTACHEMENT 1/2" STEEL EMBED PLATE MCNICOLS WELDED GALV. BAR GRATING 2" X 4" X 1/4" GALV. STEEL PLATE - MECHANICALLY FASTENED TO TUBE STEEL FRAME WITH SLIP CONNECTION 03 40 00.a PRECAST CONCRETE PANEL 1.5"x2"x1/4" GALV. STEEL ANGLE TO RUN LENGTH OF GRATING 4" X 2" X 1/4" GALV. STEEL ANGLE - 6" X 2" X 1/4" GALV. STEEL ANGLE AT GREEN SCREENS 4" X 2" X 1/4" GALV. STEEL ANGLE 4" X 2" X 1/4" STEEL ANGLE FRAME 4"x3/8" HORIZONTAL STEEL FIN - REFER ELEVATIONS FOR LOCATIONS 2"x3"x1/4" BENT PLATE - MECHANICALLY FASTENED TO HORIZONTAL FIN AT 48" O.C. 03 40 00.a PRECAST CONCRETE PANEL PRECAST PANEL REVEAL MCNICOLS WELDED BAR GRATING WITH SADDLE CLIP AT 24" SPACING 1.5"x2"x1/4" ANGLE TO RUN LENGTH OF GRATING 1" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:35 AM A511 SCREEN TYPES AND DETAILS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: 3/8" = 1'-0" SCREEN TYPES 1 GMP / PERMIT SET 13 MAY 2016 1HORIZONTAL SCALE: 3" = 1'-0" FIN DETAIL 2PLAN SCALE: 3" = DETAIL 1'-0" AT GREEN SCREENS 3PLAN SCALE: 3" = DETAIL 1'-0" AT METAL SCREENS 4SECTION SCALE: 3" = 1'-0" AT METAL SCREENS 5METAL SCALE: 3" = 1'-SCREEN 0" ELEVATION T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T M M M M M 34' - 4" 2'-11 1/4" 4'-8" 10 1/2" 2'-4" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-1" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-3 1/2" 1'-0" 11 3/4" T T T T T T T T T T T T T T T T T T T T T T T T T T M M M M M 2'-11 5/8" 3'-2" 2'-11 5/8" 9' - 1 1/8" 7' - 6 1/4" R.O. 7' - 0" R.O. 6' - 0 3/8" EQ EQ R.O. 5' - 0" R.O. 3' - 0 3/8" LEVEL 01 100' - 0" 1'-11" 4'-9 3/4" 10 1/2" 1'-6 1/2" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-1" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-3 1/2" 1'-0" 11 3/4" 4' - 2" 32' - 8" 6'-2 1/2" 2'-0" 6'-0" 2'-4 1/4" 3'-2" 2'-4 1/4" T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T M M M M M 7' - 6 1/4" 22' - 1" 32' - 8" 1'-11" 4'-9 3/4" 10 1/2" 1'-6 1/2" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-1" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-3 1/2" 1'-0" 11 3/4" 4' - 8 3/4" 2' - 0" 4' - 9 1/4" T T T T T T T T T T T T T T T T T T T T T T T T T T T M M M M M 11' - 6" LEVEL 01 100' - 0" 3' - 6" 33' - 4" 1'-11 1/4" 4'-8" 10 1/2" 2'-4" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-1" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-3 1/2" 1'-0" 11 3/4" 6' - 10 1/4" 2'-6 5/8" 5'-1 3/8" 2'-0" 5'-4" M M M M M M M M M M M M M M T T T T T T 15' - 0" 32' - 8" 11 3/4" 4'-11 1/4" 1'-6" 3'-3 1/2" 1'-0" 1'-1 1/4" 1/2" 4'-11 1/4" 1'-6" 3'-1" 1'-1 1/4" 1/2" 1'-6 1/2" 10 1/2" 1'-11" 4'-9 3/4" M M M M M M M M M M M M M M 5' - 6" 2' - 0" 5' - 5" 2' - 1" T T T T T T 15' - 0" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:33 AM A510 STOREFRONT TYPES 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE A B C1 C2 C3 C4 D1 D2 D3 1 GMP / PERMIT SET 13 MAY 2016 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:32 AM A501 EXTERIOR WALL ASSEMBLIES 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: WALL SYSTEM (SEE WALL ASSEMBLY NOTE 1) WS-6 3" = 1'-0" SCALE: WALL SYSTEM (SEE WALL ASSEMBLY NOTE 1) WS-5 3" = 1'-0" 1 GMP / PERMIT SET 13 MAY 2016 07 21 00.a 1-1/2" BOARD INSULATION 07 21 00.b R-13 BATT INSULATION (3-1/2") 07 25 00.a WEATHER/AIR BARRIER 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. PLAN U.N.O. 1" AIRSPACE 1" AIRSPACE, TYP. 04 20 00.a MASONRY VENEER F.O. STUD 6 3/4" STUD 6" NOTE: NO RIGID OR BATT INSULATION AT SIM. CONDITION SECTION 07 21 00.a 1-1/2" BOARD INSULATION 07 25 00.a WEATHER/AIR BARRIER 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 07 21 00.b R-13 BATT INSULATION (3-1/2") 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. 09 21 16.k 5/8" TYPE X EXTERIOR GYP SHEATHING 07 21 00.a 1-1/2" BOARD INSULATION 07 21 00.b R-13 BATT INSULATION (3-1/2") 07 25 00.a WEATHER/AIR BARRIER 05 40 00.b 6" METAL STUD FRAMING, RE: STRUCT. PLAN F.O. STUD 2 7/8" STUD 6" STUD 6" F.O. STUD 2 7/8" 09 22 00.0 STUCCO SYSTEM 09 22 00.0 STUCCO SYSTEM NOTE: NO RIGID OR BATT INSULATION AT SIM. CONDITION PLAN SECTION 04 20 00.l CONCRETE MASONRY UNIT 07 21 00.a 1-1/2" BOARD INSULATION 07 21 00.b R-13 BATT INSULATION (3-1/2") 05 40 00.a 3-5/8" METAL STUD FRAMING, RE: STRUCT. GARAGE SIDE RETAIL SIDE GARAGE SIDE RETAIL SIDE 07 21 00.b R-13 BATT INSULATION (3-1/2") 05 40 00.a 3-5/8" METAL STUD FRAMING, RE: STRUCT. 07 21 00.a 1-1/2" BOARD INSULATION GARAGE FINISHED FLOOR 1' - 6" 04 20 00.l CONCRETE MASONRY UNIT RETAIL FINISHED FLOOR VARIES 1" TYP. 7 5/8" 1 1/2" 3 5/8" 07 25 00.a WEATHER/AIR BARRIER 07 65 00.0 FLEXIBLE FLASHING 07 62 00.t PREFINISHED METAL COUNTERFLASHING W/DRIP EDGE - LAP OVER WEATHER/AIR BARRIER 7 5/8" 1 1/2" 3 5/8" 07 25 00.a WEATHER/AIR BARRIER 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:32 AM A500 EXTERIOR WALL ASSEMBLIES 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: WALL SYSTEM (SEE WALL ASSEMBLY NOTE 1) WS-1A 3" = 1'-0" SCALE: WALL SYSTEM (SEE WALL ASSEMBLY NOTE 1) WS-3 3" = 1'-0" SCALE: WALL SYSTEM (SEE WALL ASSEMBLY NOTE 1) WS-1B 3" = 1'-0" SCALE: WALL SYSTEM (SEE WALL ASSEMBLY NOTE 1) SCALE: WS-2 3" = 1'-0" WALL SYSTEM (SEE WALL ASSEMBLY NOTE 1) WS-4 3" = 1'-0" 1 GMP / PERMIT SET 13 MAY 2016 T.O. PANEL EL = 103' - 9" T.O. STEEL EL = 112' - 4 1/2" A604 5 SIM. 1 F 2 A309 4 A309 3 A309 A603 8 A603 4 SIM. 1 F 2 A309 4 A309 3 A309 A603 9 SIM. A603 8 1 F 2 A309 4 A309 3 A309 1 A511 1 TYP. A601 5 A606 2 T.O. PANEL EL = 129' - 5" T.O. PANEL EL = 103' - 9" T.O. STEEL EL = 112' - 4 1/2" T.O. PARAPET CAP EL = 119' - 6" T.O. PANEL EL = 118' - 9" A604 5 SIM. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:31 AM A309 ENLARGED ELEVATIONS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1ENLARGED SCALE: 3/8" = 1'-0" ELEVATION - JEFFERSON AT BRICK CORNER 2WALL SCALE: 3/8" SECTION = 1'-0" 3WALL SCALE: 3/8" SECTION = 1'-0" AT BRICK 5EAST SCALE: 3/8" BRICK = 1'-0" CORNER @ LEVEL 01 6EAST SCALE: 3/8" BRICK = 1'-0" CORNER @ LEVEL 02 7EAST SCALE: 3/8" BRICK = 1'-0" CORNER @ LEVEL 03 4WALL SCALE: 3/8" SECTION = 1'-0" Keynote Legend 03 40 00.a PRECAST CONCRETE PANEL 05 12 00.a GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 1 GMP / PERMIT SET 13 MAY 2016 SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:30 AM A308 ENLARGED ELEVATIONS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1ENLARGED SCALE: 3/8" = 1'-0" ELEVATION - NE STAIR TOWER 2WALL SCALE: 3/8" SECTION = 1'-0" - NE STAIR 3NE SCALE: STAIR 3/8" = 1'-0" TOWER @ LEVEL 01 4NE SCALE: STAIR 3/8" = 1'-0" TOWER @ LEVEL 02 5NE SCALE: STAIR 3/8" = 1'-0" TOWER @ LEVEL 03 Keynote Legend 03 30 00.0 CAST-IN-PLACE CONCRETE 03 40 00.a PRECAST CONCRETE PANEL 08 43 13.d STOREFRONT TYPICAL MULLION 08 43 13.e STOREFRONT TYPICAL MULLION WITH MULLION CAP 1 GMP / PERMIT SET 13 MAY 2016 T.O. PANEL EL = 129' - 5" T.O. PARAPET CAP EL = 124' - 6" T.O. PANEL EL = 118' - 9" FINISHED FLOOR EL = 102' - 7" 4 D 5 2 A307 3 A307 5 A307 4 A307 A603 9 4 D 5 2 A307 3 A307 5 A307 4 A307 A603 4 SIM. 4 D 5 2 A307 3 A307 5 A307 4 A307 ROOF AND OVERFLOW DRAIN, RE: PLUMBING 4 5 A604 5 A604 3 SIM. A605 8 A511 1 TYP. T.O. PANEL EL = 129' - 5" FINISHED FLOOR EL = 103' - 2" T.O. STEEL EL = 114' - 4" T.O. PANEL EL = 118' - 9" T.O. PARAPET CAP EL = 124' - 6" 4 5 A606 4 A604 5 A605 8 A601 4 A604 3 SIM. A511 1 TYP. T.O. PANEL EL = 129' - 5" T.O. STEEL EL = 114' - 4" T.O. PARAPET CAP EL = 124' - 6" T.O. PANEL EL = 118' - 9" FINISHED FLOOR EL = 103' - 2" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:28 AM A307 ENLARGED ELEVATIONS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1ENLARGED SCALE: 3/8" = 1'-0" ELEVATION - FIREHOUSE ALLEY AT RETAIL 2WALL SCALE: 3/8" SECTION = 1'-0" - RETAIL ENTRANCE 3WALL SCALE: 3/8" SECTION = 1'-0" - BRICK AT RETAIL 6FIREHOUSE SCALE: 3/8" = 1'-0" ALLEY RETAIL ENTRANCE @ LEVEL 01 7FIREHOUSE SCALE: 3/8" = 1'-0" ALLEY RETAIL ENTRANCE @ LEVEL 02 8FIREHOUSE SCALE: 3/8" = 1'-0" ALLEY RETAIL ENTRANCE @ LEVEL 03 5WALL SCALE: 3/8" SECTION = 1'-0" - OVERHEAD DOOR 4WALL SCALE: 3/8" SECTION = 1'-0" - RETAIL BRICK ACCENTS Keynote Legend 03 40 00.a PRECAST CONCRETE PANEL 05 12 00.a GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT CAST STONE CAP 1 GMP / PERMIT SET 13 MAY 2016 WS-2 T.O. STEEL EL = 114' - 4" A604 3 SIM. A605 8 A604 5 A511 1 TYP. T.O. PANEL EL = 129' - 5" T.O. PARAPET CAP EL = 124' - 6" T.O. PANEL EL = 118' - 9" 4 F 5 3 A306 2 A306 A603 9 A603 3 O.H. 4 F 5 3 A306 2 A306 A603 4 SIM. A603 4 O.SIM. H. 4 F 5 3 A306 2 A306 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:27 AM A306 ENLARGED ELEVATIONS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1ENLARGED SCALE: 3/8" = 1'-0" ELEVATION - FIREHOUSE ALLEY RETAIL CORNER 2WALL SCALE: 3/8" SECTION = 1'-0" 3WALL SCALE: 3/8" SECTION = 1'-0" 4FIREHOUSE SCALE: 3/8" = 1'-0" ALLEY RETAIL @ LEVEL 01 5FIREHOUSE SCALE: 3/8" = 1'-0" ALLEY RETAIL @ LEVEL 02 6FIREHOUSE SCALE: 3/8" = 1'-0" ALLEY RETAIL @ LEVEL 03 Keynote Legend 03 40 00.a PRECAST CONCRETE PANEL 05 12 00.a GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 05 50 00.f PLATE STEEL, RE: STRUCT 1 GMP / PERMIT SET 13 MAY 2016 WS-3 T.O. PARAPET CAP EL = 143' - 8" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:26 AM A305 ENLARGED ELEVATIONS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1SW SCALE: STAIR 3/8" = 1'-0" @ LEVEL 01 2SW SCALE: STAIR 3/8" = 1'-0" @ LEVEL 02 3SW SCALE: STAIR 3/8" = 1'-0" @ LEVEL 03 1 GMP / PERMIT SET 13 MAY 2016 4WALL SCALE: 3/8" SECTION = 1'-0" ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:25 AM A304 ENLARGED ELEVATIONS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1ENLARGED SCALE: 3/8" = 1'-0" ELEVATION - FIREHOUSE ALLEY STAIR TOWER 2WALL SCALE: 3/8" SECTION = 1'-0" 3WALL SCALE: 3/8" SECTION = 1'-0" Keynote Legend 03 30 00.n CAST IN PLACE ARCHITECTURAL CONC., RE: STRUCT 03 40 00.a PRECAST CONCRETE PANEL 05 12 00.a GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 08 43 13.d STOREFRONT TYPICAL MULLION 08 43 13.e STOREFRONT TYPICAL MULLION WITH MULLION CAP 1 GMP / PERMIT SET 13 MAY 2016 7 A602 6 A.4 1 1.3 2 A303 3 A303 3' - 11" 3' - 11" 8' - 6 1/8" 24' - 10" A.4 1 1.3 2 A303 3 A303 A.4 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:24 AM A303 ENLARGED ELEVATIONS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1ENLARGED SCALE: 3/8" = 1'-0" ELEVATION - NORTH AT STAIR TOWER 2WALL SCALE: 3/8" SECTION = 1'-0" - NE STAIR AT SIGNAGE 3WALL SCALE: 3/8" SECTION = 1'-0" - NE STAIR AT STOREFRONT 4NE SCALE: STAIR 3/8" = 1'-0" @ LEVEL 01 5NE SCALE: STAIR 3/8" = 1'-0" @ LEVEL 02 6NE SCALE: STAIR 3/8" = 1'-0" @ LEVEL 03 Keynote Legend 03 30 00.0 CAST-IN-PLACE CONCRETE 08 43 13.d STOREFRONT TYPICAL MULLION 08 43 13.e STOREFRONT TYPICAL MULLION WITH MULLION CAP 1 GMP / PERMIT SET 13 MAY 2016 3.7 G 2 A302 F T.O. STEEL EL = 114' - 4" A605 7 A601 2 A604 4 A511 1 TYP. WS-1B WS-1A WS-2 A604 3 FINISHED FLOOR EL = 102' - 5" T.O. PANEL EL = 129' - 5" WS-5 T.O. PARAPET CAP EL = 124' - 6" 3.7 G 2 A302 A602 5 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:21 AM A302 ENLARGED ELEVATIONS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1ENLARGED SCALE: 3/8" = 1'-0" ELEVATION - CHESTNUT AT STAIR TOWER 4CHESTNUT SCALE: 3/8" = 1'-0" STAIR @ LEVEL 01 2WALL SCALE: 3/8" SECTION = 1'-0" 5CHESTNUT SCALE: 3/8" = 1'-0" STAIR @ LEVEL 02 6CHESTNUT SCALE: 3/8" = 1'-0" STAIR @ LEVEL 03 3WALL SCALE: 3/8" SECTION = 1'-0" 7CHESTNUT SCALE: 3/8" = 1'-0" STAIR @ ROOF METAL PANEL BEYOND Keynote Legend 03 30 00.0 CAST-IN-PLACE CONCRETE 03 30 00.c CONC. WALL, RE: STRUCT 03 40 00.a PRECAST CONCRETE PANEL 05 12 00.a GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 08 43 13.d STOREFRONT TYPICAL MULLION 08 43 13.e STOREFRONT TYPICAL MULLION WITH MULLION CAP 1 GMP / PERMIT SET 13 MAY 2016 SIM. G A604 1 A604 2 T.O. STEEL EL = 110' - 0" B.O. STEEL EL = 111' - 0" 9' - 0" CLR. WS-1B WS-1A SIM. SIM. WS-1B SIM. 5' - 0" A511 1 TYP. T.O. PANEL EL = 129' - 5" T.O. PARAPET CAP EL = 119' - 6" T.O. PANEL EL = 118' - 9" T.O. PANEL EL = 103' - 9" G 4 A301 3 A301 2 A301 A602 1 A511 3 A511 2 G 4 A301 3 A301 2 A301 A602 3 G 4 A301 3 A301 2 A301 G 4 A301 3 A301 2 A301 A602 2 G A511 4 T.O. PANEL EL = 129' - 5" 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:19 AM A301 ENLARGED ELEVATIONS AND SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1ENLARGED SCALE: 3/8" = 1'-0" ELEVATION - CHESTNUT AT ENTRY 3WALL SCALE: 3/8" SECTION = 1'-0" 4WALL SCALE: 3/8" SECTION = 1'-0" 5CHESTNUT SCALE: 3/8" = 1'-0" ENTRY @ LEVEL 01 7CHESTNUT SCALE: 3/8" = 1'-0" ENTRY @ LEVEL 02 8CHESTNUT SCALE: 3/8" = 1'-0" ENTRY @ LEVEL 03 6CHESTNUT SCALE: 3/8" = 1'-0" ENTRY @ BRICK INSET 2WALL SCALE: 3/8" SECTION = 1'-0" Keynote Legend 03 40 00.a PRECAST CONCRETE PANEL 05 12 00.a GALV. STEEL C CHANNEL; RE: STRUCT FOR ATTACHMENT 1 GMP / PERMIT SET 13 MAY 2016 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" G F.6 F C4 6" DOWNSPOUT AND SCUPPER TO MATCH METAL PANEL 6" DOWNSPOUT AND SCUPPER TO ALIGN AND MATCH METAL PANEL PREFINISHED METAL COPING LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 1.3 1 D1 6" DOWNSPOUT AND SCUPPER TO MATCH METAL PANEL PREFINISHED METAL COPING 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:18 AM A250 BUILDING SECTIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1EAST-SCALE: 3/32" WEST = 1'-0" SECTION 3NORTH-SCALE: 3/32" = 1'-SOUTH 0" SECTION 2EAST-SCALE: 3/32" WEST = 1'-0" SECTION THRU LOWER RAMP 4TRENCH SCALE: 1" = 1'-0" DRAIN DETAIL 5BUILDING SCALE: 3/32" = 1'-0" SECTION - SW STAIR TOWER 6BUILDING SCALE: 3/32" = 1'-0" SECTION - NE STAIR TOWER 1 GMP / PERMIT SET 13 MAY 2016 LEVEL 03 125' - 8" ROOF 136' - 10" A B C D E F G 1 A250 1 A250 ALUMINUM STOREFRONT SIGNAGE TO BE APPROVED INTERLOCKING METAL PANEL (ZINC) TO MATCH HOTEL PREFINISHED GALVANIZED METAL COPING EXTERIOR PLASTER FINISH PANEL TO RECEIVE "ALLEY ART", TYP. (3) BAYS GALVANIZED STEEL "C" CHANNEL BRICK VENEER INTEGRAL COLOR PRECAST CONCRETE SPANDREL METAL GRATE WITH GALVANIZED STEEL FRAME TO SUPPORT "GREEN SCREEN" SYSTEM VINES STOREFRONT WINDOW PV ARRAY BEYOND (ALTERNATE) SECTIONAL OVERHEAD DOOR CONTINUOUS PRECAST REVEALS CONTINUOUS STEEL PLATE FIN A304 1 A306 1 A307 1 A.3 F.6 CORBELLED BRICK BANDING BRICK SOLDIER COURSE T.O. PANEL EL = 107' - 2" T.O. PANEL EL = 129' - 5" 2 A250 2 A250 GALVANIZED STEEL FRAME CANOPY WITH INFILL PERFORATED METAL GRATE C1 C2 A A A T.O. PANEL EL = 120' - 1" DASHED LINE OF ROOF BEYOND DASHED LINE OF BRICK LEDGE BELOW - RE: STRUCT F3 E3 F3 F3 F3 E3 F3 E3 F3 E3 F3 E3 F3 F3 E3 F3 E3 OVERFLOW DRAIN DOWNSPOUT NOZZLE - CENTER ON BRICK PILASTER, TYP. A.4 LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 1 1.3 1.6 2 3 3.7 4 3 A250 3 A250 5 INTEGRAL COLOR PRECAST CONCRETE SPANDREL METAL GRATE WITH GALVANIZED STEEL FRAME TO SUPPORT "GREEN SCREEN" SYSTEM VINES SIGNAGE TO BE APPROVED ALUMINUM STOREFRONT RAMP, BEYOND PV ARRAY BEYOND (ALTERNATE) CONTINUOUS STEEL PLATE FIN A303 1 T.O. PANEL EL = 129' - 5" GALVANIZED STEEL FRAME CANOPY WITH INFILL PERFORATED METAL GRATE CONTINUOUS PRECAST REVEAL D3 T.O. PANEL EL = 109' - 3" T.O. PANEL EL = 118' - 9" T.O. PANEL EL = 120' - 1" F3 E3 E3 F3 E3 F3 E3 F3 E3 F3 F3 E3 F3 E3 F3 E3 INTERLOCKING METAL PANEL (ZINC) TO MATCH HOTEL LEVEL 01 100' - 0" LEVEL 02 115' - 0" LEVEL 03 125' - 8" ROOF 136' - 10" 4 3.7 3 2 1.6 1.3 1 3 A250 3 5 A250 PRECAST REVEAL METAL GRATE WITH GALVANIZED STEEL FRAME TO SUPPORT "GREEN SCREEN" SYSTEM VINES INTREGAL COLOR PRECAST CONCRETE SPANDREL BRICK VENEER SIGNAGE TO BE APPROVED GALVANIZED STEEL FRAME CANOPY WITH INFILL PREFORATED METAL GRATE CONTINUOUS STEEL PLATE FIN A302 1 A301 1 T.O. PANEL EL = 103' - 9" T.O. PANEL EL = 118' - 9" GALVANIZED STEEL FRAME T.O. PANEL EL = 129' - 5" CANOPY WITH INFILL PERFORATED METAL GRATE ALUMINUM STOREFRONT PV ARRAY BEYOND (ALTERNATE) GALVANIZED STEEL "C" CHANNEL STOREFRONT WINDOW BRICK SOLDIER COURSE EXTERIOR PLASTER FINISH PANEL TO RECEIVE "ALLEY ART" GALVANIZED STEEL "C" CHANNEL ANGLE CANOPY SUPPORTS C3 B DASHED LINE OF ROOF BEYOND DASHED LINE OF BRICK LEDGE BELOW - RE: STRUCT E1 F1 E1 F1 F1 E1 F1 E1 F1 A1 C C A1 A1 A1 F1 E1 F1 E1 F1 E1 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:13 AM A200 GARAGE ELEVATIONS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 4EAST SCALE: 3/32" (JEFFERSON) = 1'-0" 3WEST SCALE: 3/32" (= FIREHOUSE 1'-0" ALLEY) 2NORTH SCALE: 3/32" = 1'-0" 1SOUTH SCALE: 3/32" = (1'-CHESTNUT) 0" 1 GMP / PERMIT SET 13 MAY 2016 GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:00 AM A104 ROOF PLAN 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: N 1ROOF 3/32" PLAN = 1'-0" 1 GMP / PERMIT SET 13 MAY 2016 A250 2 A250 RAMP BELOW CUT LINE SEE A102 5 A250 17 A250 6 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% FINISH FLOOR EL = 124' - 4" EL = 125' - 8" FINISH FLOOR EL = 125' - 4" FINISH FLOOR EL = 125' - 8" FINISH FLOOR EL = 124' - 4" FINISH FLOOR EL = 124' - 4" FINISH FLOOR EL = 125' - 8" FINISH FLOOR FINISH FLOOR EL = 124' - 4" FINISH FLOOR EL = 124' - 4" FINISH FLOOR EL = 125' - 4" FINISH FLOOR EL = 125' - 5 1/2" EL = 125' - 8" FINISH FLOOR FINISH FLOOR EL = 125' - 8" FINISH FLOOR FINISH FLOOR EL = 125' - 5" FINISH FLOOR EL = 125' - 1" FINISH FLOOR EL = 125' - 1" FINISH FLOOR RAMP DOWN 6.67% DN FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR ELEV. STAIR 01 STAIR 02 SLAB LEAVE OUT FOR FUTURE SHAFT ENCLOSURE INFILL LEAVEOUT WITH GALVANIZED METAL GRATE TO MATCH SCREENS ELEV. CONTROL ROOM SLAB LEAVE OUT FOR FUTURE SHAFT ENCLOSURE INFILL LEAVEOUT WITH GALVANIZED METAL GRATE TO MATCH SCREENS 2.0% EL = 124' - 11" EL = 124' - 11" EL = 124' - 11" EL = 124' - 11" EL = 124' - 11" EL = 125' - 1" FINISH FLOOR WS-3 WS-3 A.4 1/2" /12" MIN 1/2" /12" MIN 1/2" /12" MIN 1/2" /12" MIN RIDGE ROOF DRAIN AND OVERFLOW DRAIN RE: PLUMBING ROOF DRAIN AND OVERFLOW DRAIN RE: PLUMBING F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. SIM. WS-3 WS-3 SIM. SIM. 18 19 WS-3 WS-3 WS-3 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:32:57 AM A103 FLOOR PLAN LEVEL 3 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: N 1THIRD 3/32" LEVEL = 1'-0" FLOOR PLAN 1 GMP / PERMIT SET 13 MAY 2016 A702 2 6" DIA. BOLLARD WS-3 2 A250 2 A250 5 A250 28' - 9 3/8" 14 15 A250 6 EV EV EV EV EV EV EV EV ELECTRIC VEHICLE CHARING STATION, TYP. OF (4) WS-3 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% EL = 113' - 8" EL = 115' - 0" EL = 114' - 8" EL = 113' - 8" EL = 113' - 8" EL = 115' - 0" EL = 113' - 8" EL = 114' - 9 1/2" EL = 115' - 0" EL = 115' - 0" EL = 114' - 9" EL = 114' - 5" FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR EL = 114' - 5" FINISH FLOOR EL = 114' - 8" EL = 114' - 5" FINISH FLOOR EL = 114' - 9" FINISH FLOOR EL = 113' - 8" EL = 113' - 8" RAMP DOWN 6.67% DN RAMP DOWN 6.67% DN EXPRESS RAMP DOWN 13.6% DN 13.6% DN EXPRESS RAMP DOWN 6.67% UP RAMP UP 6.67% UP RAMP UP EL = 114' - 3" FINISH FLOOR EL = 114' - 3" FINISH FLOOR EL = 114' - 3" EL = 114' - 3" FINISH FLOOR FINISH FLOOR ELEV. STAIR 01 STAIR 02 SLAB LEAVE OUT FOR FUTURE SHAFT ENCLOSURE INFILL LEAVEOUT WITH GALVANIZED METAL GRATE TO MATCH SCREENS F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. 2'-0" 9'-0 1/2" 1'-11" 1" SLAB LEAVE OUT FOR FUTURE SHAFT ENCLOSURE INFILL LEAVEOUT WITH GALVANIZED METAL GRATE TO MATCH SCREENS A.4 REFER A103 RAMP UP REFER A101 RAMP DOWN 1/2" /12" MIN 1/2" /12" MIN 1/2" /12" MIN 1/2" /12" MIN RIDGE ROOF AND OVERFLOW DRAIN RE: PLUMBING ROOF AND OVERFLOW DRAIN RE: PLUMBING WS-3 WS-3 WS-3 SIM. 2'-0" 2'-0" WS-3 WS-3 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:32:50 AM A102 FLOOR PLAN LEVEL 2 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: N 1SECOND 3/32" = 1'-0" LEVEL FLOOR PLAN 1 GMP / PERMIT SET 13 MAY 2016 2 SPACES 2 SPACES 3 SPACES 3 SPACES 4 SPACES FINISH FLOOR FINISH FLOOR 4 SPACES 2 SPACES 2 SPACES CARD READER AND GATE CARD READER AND GATE PAY STATION (ALTERNATE) EMERGENCY CALL BOX (ALTERNATE) PAY STATION (ALTERNATE) EMERGENCY CALL BOX (ALTERNATE) A.3 F.6 FINISH FLOOR EL = 103' - 3 1/2" FINISH FLOOR A702 1 A701 1 STORAGE ROOM 8" TRENCH DRAIN - WIDTH OF RAMP RAMP UP 1% EMERGENCY CALL BOX (ALTERNATE) MECH. ROOM 6" DIA. BOLLARD 1.5% 1.5% 1.2% 1.5% 1.7% 1.5% WS-3 WS-3 2 A250 2 A250 WS-5 WS-5 WS-5 WS-5 WS-5 SIM. WS-5 WS-5 WS-5 WS-5 SIM. SIM. SIM. WS-5 WS-5 EXTENTS OF FUTURE RETAIL/OFFICE EL = 104' - 1 1/2" SLOPE LANDING AWAY FROM DOORS FOR WATER DRAINAGE EL = 103' - 3 1/2" C4 D1 5 A250 8 9 10 13 11 2 3 4 5 6 7 1 12 EL = 102' - 5" EL = 102' - 7" EL = 103' - 2" EL = 102' - 6" FINISH FLOOR 2'-9" EL = 100' - 0" FINISH FLOOR EL = 100' - 0" FINISH FLOOR 3' - 0" 3' - 0" 20' - 8" EL = 100' - 0" FINISH FLOOR 1% UP A250 6 PIPE BOLLARD, TYP. RE. PK DRAWINGS WS-4 WS-4 35' - 9" 19' - 0" 16' - 9" RAMP DOWN 6.67% DN RAMP DOWN 6.67% DN EXPRESS RAMP DOWN 13.6% DN 13.6% DN EXPRESS RAMP DOWN RAMP DOWN 1% DN RAMP DOWN 1% DN SERVER ROOM ELEC. ROOM STAIR 02 175'-6" 3'-9 1/8" 3'-10 3/4" 10'-0 7/8" 9'-6 3/8" 1'-9 1/8" 6'-0 3/8" 4'-0 1/4" 1'-10 3/4" 2'-0 7/8" 4'-0 1/4" 14'-6 1/8" 14'-6 1/8" 2'-0 7/8" 4'-0 1/4" 1'-10 3/4" 2'-0 7/8" 2'-10 3/4" 13'-7 7/8" 2'-11 5/8" 2'-11 5/8" 13'-1 1/2" 2'-8 5/8" 6'-3 3/8" 3'-11 5/8" 3'-0" 1'-8 5/8" 2'-3" 3'-0" 3'-0" 1'-8 5/8" 2'-3" 3'-0" 2'-3" 5'-0 3/8" 1'-8 5/8" 3'-11 5/8" 4'-1 1/2" 6'-3 3/4" 18'-8" 2'-7 1/2" 12'-0" F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. A.4 WS-3 WS-3 CAR COUNT 9'-0" 90° STANDARD SPACE 8'-9" 65° STANDARD SPACE TIER GROUND SECOND THIRD TOTAL STANDARD CAR ACCESSIBLE VAN ACCESSIBLE TOTAL 96 117 114 327 2 2 2 6 2 0 0 2 100 119 116 335 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:32:46 AM A101 FLOOR PLAN LEVEL 1 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: N 1FIRST 3/32" LEVEL = 1'-0" FLOOR PLAN 1 GMP / PERMIT SET 13 MAY 2016 ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:32:43 AM A001 SITE PLAN 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: N 1SITE 1/PLAN 16" = 1'-0" 1 GMP / PERMIT SET 13 MAY 2016 GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:34:19 AM G351 DETAILS - ACCESSIBILITY MOUNTING HEIGHTS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE SCALE: 3/4" = 1'-0" FIRE PROTECTION & ELECTRICAL MOUNTING HEIGHTS 1 GMP / PERMIT SET 13 MAY 2016 MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:34:18 AM G203 CODE ANALYSIS - EGRESS & TRAVEL DISTANCE 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1EGRESS SCALE: 3/32" = 1'-0" & TRAVEL DISTANCE - LEVEL 03 1 GMP / PERMIT SET 13 MAY 2016 ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:34:15 AM G202 CODE ANALYSIS - EGRESS & TRAVEL DISTANCE 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1EGRESS SCALE: 3/32" = 1'-0" & TRAVEL DISTANCE - LEVEL 02 1 GMP / PERMIT SET 13 MAY 2016 (<100'-0" MAX.) COMMON PATH OF EGRESS TRAVEL = 32' - 3" (<100'-0" MAX.) 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:34:08 AM G201 CODE ANALYSIS - EGRESS & TRAVEL DISTANCE 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1EGRESS SCALE: 3/32" = 1'-0" & TRAVEL DISTANCE - LEVEL 01 1 GMP / PERMIT SET 13 MAY 2016 PARTITIONS CORRIDORS PER UBC 1018.1. .5 HR @ R OCCUPANCY NR NOT 20 MIN REQUIRED FIRE PARTITION IN/EXTERIOR WALLS INTERIOR AND EXTERIOR NON-RATED WALLS (PER OCCUPANCY - IBC 302) NR NR NOT REQUIRED NOT REQUIRED EXIT ENCLOSURES, ALL SHAFT WALLS, AND EXIT PASSAGE WALL. ALSO ALL FLOOR AND CEILING ASSEMBLIES 2 HR 1.5 HR (NOT REQ'D WHERE EXCEPTIONS ARE MET) NOT REQUIRED FIRE WALL 90 MIN SMOKE BARRIERS ELEVATOR LOBBY (IBC 713.14.1) NR NR NOT 20 MIN REQUIRED CUMULATIVE OCCUPANCY LOAD EXIT OCCUPANT LOAD X Y OR Y Z FIRE BARRIERS (IBC 707) TYPE HR RATING < 4 STORIES STAIRWAYS 1HR (2HR*) HR RATING > 4 STORIES 2HR SHAFTS 1HR (2HR*) 2HR HOR. EXIT 2HR NA EXIT PASSAGEWAY 1HR NA INCIDENTAL USES 1HR OR SPRINKLER 1HR OR SPRINKLER * FIRE HR RATING IS NOT TO BE LESS THEN FLOOR ASSEMBLY PENETRATED. (IBC 2012 SECTION 713.4) ELEV. STAIR 01 STAIR 02 OCCUPANCY: AREA SUBTOTAL: LOAD FACTOR: OCCUPANT LOAD: FUNCTION: 39597 SF PARKING 200 SF 198 S-2 PARKING REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: REQ'D STAIR WIDTH: STAIR 02 99 .15"/OCC = 14.85" < 36" ACTUAL .30"/OCC = 29.7" < 48" ACTUAL 99 99 REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: REQ'D STAIR WIDTH: STAIR 01 99 .15"/OCC = 14.85" < 68" ACTUAL .30"/OCC = 29.7" < 48" ACTUAL OPEN TO RAMP BELOW 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:34:06 AM G103 CODE ANALYSIS - FIRE RATED WALLS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1LEVEL SCALE: 3/32" 03 = 1'-0" 1 GMP / PERMIT SET 13 MAY 2016 (2) SEE MECHANICAL DOCUMENTATION FOR LOCATIONS OF FIRE DAMPERS. (3) SEE MECHANICAL DOCUMENTATION FOR LOCATIONS OF SMOKE DAMPERS. (4) SEE ARCHITECTURAL DOCUMENTATION FOR LOCATIONS OF FIRE DOORS AND FIRE SHUTTERS. (5) NOT REQUIRED AT PENETRATION OF EXHAUST OR SUPPLY SHAFTS IN PARKING GARAGES THAT ARE SEPARATED FROM OTHER BUILDING SHAFTS BY NOT LESS THAN 2 HR FIRE RESISTANCE RATED CONSTRUCTION. WALLS SEPARATING DWELLING UNITS OR SLEEPING UNITS, AND OCCUPANCY SEPARATIONS CLASSIFICATION PER IBC 302 1 HR 1 HR EXTERIOR WALL @ TRANSFORMER AND GENERATOR 3 HR NR NOT REQUIRED NA NOT 20 MIN REQUIRED FIRE WALL DESIGN OCCUPANCY LOAD FIRE PARTITIONS CORRIDORS PER UBC 1018.1. .5 HR @ R OCCUPANCY NR NOT 20 MIN REQUIRED FIRE PARTITION IN/EXTERIOR WALLS INTERIOR AND EXTERIOR NON-RATED WALLS (PER OCCUPANCY - IBC 302) NR NR NOT REQUIRED NOT REQUIRED EXIT ENCLOSURES, ALL SHAFT WALLS, AND EXIT PASSAGE WALL. ALSO ALL FLOOR AND CEILING ASSEMBLIES 2 HR 1.5 HR (NOT REQ'D WHERE EXCEPTIONS ARE MET) NOT REQUIRED FIRE WALL 90 MIN SMOKE BARRIERS ELEVATOR LOBBY (IBC 713.14.1) NR NR NOT 20 MIN REQUIRED CUMULATIVE OCCUPANCY LOAD EXIT OCCUPANT LOAD X Y OR Y Z FIRE BARRIERS (IBC 707) TYPE HR RATING < 4 STORIES STAIRWAYS 1HR (2HR*) HR RATING > 4 STORIES 2HR SHAFTS 1HR (2HR*) 2HR HOR. EXIT 2HR NA EXIT PASSAGEWAY 1HR NA INCIDENTAL USES 1HR OR SPRINKLER 1HR OR SPRINKLER * FIRE HR RATING IS NOT TO BE LESS THEN FLOOR ASSEMBLY PENETRATED. (IBC 2012 SECTION 713.4) SHEET NOTES: 1. SEE A500 SERIES FOR WALL TYPES. ALL FIRE RATED WALLS/BARRIERS WILL EXTEND TO THE OUTSIDE FACE OF ALL WALL ASSEMBLIES 2. ALL RATED WALLS WILL INCLUDE DOOR OPENING, HEADER, AND FRAMES 3. ALL INTERIOR SHAFTS WILL BE 2HR RATED 4. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:34:03 AM G102 CODE ANALYSIS - FIRE RATED WALLS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1LEVEL SCALE: 3/32" 02 = 1'-0" 1 GMP / PERMIT SET 13 MAY 2016 ELEC. ROOM ELEV. OCCUPANCY: AREA SUBTOTAL: LOAD FACTOR: OCCUPANT LOAD: FUNCTION: 83 SF SERVER ROOM 160 SF 1 B SERVER OCCUPANCY: AREA SUBTOTAL: LOAD FACTOR: OCCUPANT LOAD: FUNCTION: 83 SF ELECTRICAL 300 SF 1 MECH. ELECTRICAL REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: REQ'D STAIR WIDTH: STAIR 01 150 .15"/OCC = 22.5" <36.0" ACTUAL .20"/OCC = 30.0" < X44.0" ACTUAL OCCUPANCY: AREA SUBTOTAL: LOAD FACTOR: OCCUPANT LOAD: FUNCTION: 35942 SF PARKING 200 SF 180 S-2 PARKING 4 1 1 1 95 95 2 92 REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: EXIT DOOR LV. 1 92 .15"/OCC = 13.8" < 36" ACTUAL REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: EXIT DOOR LV. 1 95 .15"/OCC = 14.25" < 38" ACTUAL 95 29.3 29.3 29.3 29.3 29.3 29.3 REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: EXIT DOOR LV. 1 29.3 .15"/OCC = 4.4" < 48" ACTUAL REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: EXIT DOOR LV. 1 29.3 .15"/OCC = 4.4" < 48" ACTUAL REQ'D DOOR WIDTH: TOTAL EGRESS LOAD: EXIT DOOR LV. 1 29.3 .15"/OCC = 4.4" < 48" ACTUAL 90 90 92 <154'-7" DEAD END CORRIDOR (SECTION 1018.4) 60'-3 7/8" < 2.5xWIDTH 61'-10" FIRE RESISTANCE - RATED WALL LEGEND (IBC 708) WALL SYMBOL DESCRIPTION LOCATION / PURPOSE FIRE RESISTIVE RATING (1) FIRE DAMPER RATING (2) SMOKE DAMPER RATING (3) FIRE DOOR / SHUTTER RATING (4) NOTES: (1) THE FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE > 5 FEET SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE; FOR A FIRE SEPARATION DISTANCE < OR = 5 FEET, SUCH WALLS SHALL BE RATED FOR EXPOSURE TO FIRE FROM BOTH SIDES. (2) SEE MECHANICAL DOCUMENTATION FOR LOCATIONS OF FIRE DAMPERS. (3) SEE MECHANICAL DOCUMENTATION FOR LOCATIONS OF SMOKE DAMPERS. (4) SEE ARCHITECTURAL DOCUMENTATION FOR LOCATIONS OF FIRE DOORS AND FIRE SHUTTERS. (5) NOT REQUIRED AT PENETRATION OF EXHAUST OR SUPPLY SHAFTS IN PARKING GARAGES THAT ARE SEPARATED FROM OTHER BUILDING SHAFTS BY NOT LESS THAN 2 HR FIRE RESISTANCE RATED CONSTRUCTION. WALLS SEPARATING DWELLING UNITS OR SLEEPING UNITS, AND OCCUPANCY SEPARATIONS CLASSIFICATION PER IBC 302 1 HR 1 HR EXTERIOR WALL @ TRANSFORMER AND GENERATOR 3 HR NR NOT REQUIRED NA NOT 20 MIN REQUIRED FIRE WALL DESIGN OCCUPANCY LOAD FIRE PARTITIONS CORRIDORS PER UBC 1018.1. .5 HR @ R OCCUPANCY NR NOT 20 MIN REQUIRED FIRE PARTITION IN/EXTERIOR WALLS INTERIOR AND EXTERIOR NON-RATED WALLS (PER OCCUPANCY - IBC 302) NR NR NOT REQUIRED NOT REQUIRED EXIT ENCLOSURES, ALL SHAFT WALLS, AND EXIT PASSAGE WALL. ALSO ALL FLOOR AND CEILING ASSEMBLIES 2 HR 1.5 HR (NOT REQ'D WHERE EXCEPTIONS ARE MET) NOT REQUIRED FIRE WALL 90 MIN SMOKE BARRIERS ELEVATOR LOBBY (IBC 713.14.1) NR NR NOT 20 MIN REQUIRED CUMULATIVE OCCUPANCY LOAD EXIT OCCUPANT LOAD X Y OR Y Z FIRE BARRIERS (IBC 707) TYPE HR RATING < 4 STORIES STAIRWAYS 1HR (2HR*) HR RATING > 4 STORIES 2HR SHAFTS 1HR (2HR*) 2HR HOR. EXIT 2HR NA EXIT PASSAGEWAY 1HR NA INCIDENTAL USES 1HR OR SPRINKLER 1HR OR SPRINKLER * FIRE HR RATING IS NOT TO BE LESS THEN FLOOR ASSEMBLY PENETRATED. (IBC 2012 SECTION 713.4) SHEET NOTES: 1. SEE A500 SERIES FOR WALL TYPES. ALL FIRE RATED WALLS/BARRIERS WILL EXTEND TO THE OUTSIDE FACE OF ALL WALL ASSEMBLIES 2. ALL RATED WALLS WILL INCLUDE DOOR OPENING, HEADER, AND FRAMES 3. ALL INTERIOR SHAFTS WILL BE 2HR RATED 4. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:34:00 AM G101 CODE ANALYSIS - FIRE RATED WALLS 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1LEVEL SCALE: 3/32" 01 = 1'-0" 1 GMP / PERMIT SET 13 MAY 2016 TABLE 705.8) FIRE SEPARATION DISTANCE 5' TO 10' UNPROTECTED, NONSPRINKLERED (UP, NS) ALLOWABLE AREA: 10% . MAX. AREA OF EXTERIOR. WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE. (IBC TABLE 705.8) FIRE SEPARATION DISTANCE 15' TO 20' UNPROTECTED, NONSPRINKLERED (UP, NS) ALLOWABLE AREA: 25% OPEN PARKING EXCEPTION: NO LIMIT . MAX. AREA OF EXTERIOR. WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE. (IBC TABLE 705.8) FIRE SEPARATION DISTANCE 10' TO 15' UNPROTECTED, NONSPRINKLERED (UP, NS) ALLOWABLE AREA: 15% OPEN PARKING EXCEPTION: NO LIMIT . MAX. AREA OF EXTERIOR. WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE. (IBC TABLE 705.8) FIRE SEPARATION DISTANCE 15' TO 20' UNPROTECTED, NONSPRINKLERED (UP, NS) ALLOWABLE AREA: 25% OPEN PARKING EXCEPTION: NO LIMIT . MAX. AREA OF EXTERIOR. WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE. (IBC TABLE 705.8) FIRE SEPARATION DISTANCE 25' TO 30' UNPROTECTED, NONSPRINKLERED (UP, NS) ALLOWABLE AREA: 70% OPEN PARKING EXCEPTION: NO LIMIT 54'-10 3/8" 74'-9 7/8" 56'-5 7/8" 50'-5 3/4" 56'-5 3/8" 54'-2 3/8" MAX. AREA OF EXTERIOR WALL OPENING TO R.O.W. - FIRE SEPARATION DIST. & DEGREE OF OPENING PROTECTION - (IBC TABLE 705.8) SYMBOL FIRE SEPARATION DIST. ALLOWABLE AREA NOTES: G. THE AREA OF OPENINGS IN AN OPEN PARKING STRUCTURE WITH A FIRE SEPERATION DISTANCE OF 10 FEET OR GREATER SHALL NOT BE LIMITED. EXTERIOR WALL 15' TO LESS THAN 20' 25% 45% DEGREE OF OPENING PROTECTION EXTERIOR WALL 20' TO LESS THAN 25' EXTERIOR WALL 5' TO LESS THAN 10' 10% EXTERIOR WALL 15% 10' TO LESS THAN 15' *G EXTERIOR WALL 0' TO LESS THAN 3' UNPROTECTED, NONSPRINKLER NOT PERMITTED (UP,NS) EXTERIOR WALL 3' TO LESS THAN 5' UNPROTECTED, NONSPRINKLER (UP,NS) UNPROTECTED, NONSPRINKLER (UP,NS) UNPROTECTED, NONSPRINKLER (UP,NS) UNPROTECTED, NONSPRINKLER (UP,NS) UNPROTECTED, NONSPRINKLER (UP,NS) NOT PERMITTED EXTERIOR WALL 45% 25' TO LESS THAN 30' UNPROTECTED, NONSPRINKLER (UP,NS) EXTERIOR WALL 45% 30' OR GREATER UNPROTECTED, NONSPRINKLER (UP,NS) *G *G *G *G *G *G *G *G *G IBC SECTION 406.5.2 OPENINGS FOR NATURAL VENTILATION PURPOSES THE EXTERIOR SIDE OF THE STRUCTURE SHALL HAVE UNIFORMILY DISTRIBUTED OPENINGS ON TWO OR MORE SIDES. THE AREA OF SUCH OPENINGS IN EXTERIOR WALLS ON A TIER SHALL BE NOT LESS THAN 20 PERCENT OF THE TOAL PERIMETER WALL AREA OF EACH TIER. THE AGGREGATE LENGTH OF THE OPENINGS CONDISERED TO BE PROVIDING NATURAL VENTILATION SHALL BE NOT LESS THAN 40 PERCENT OF THE PRIMETER OF THE TIER. INTERIOR WALLS SHALL BE NOT LESS THAN 20 PERCENT OPEN WITH UNIFORMILY DISTRIBUTED OPENINGS. NORTH ELEVATION TOTAL AREA (sf) TOTAL CLOSED AREA (sf) TOTAL OPEN AREA (sf) OPEN AREA (%) FIRST FLOOR SECOND FLOOR 1231 1231 1113 1116 118 115 10% 9% WEST ELEVATION TOTAL AREA (sf) TOTAL CLOSED AREA (sf) TOTAL OPEN AREA (sf) OPEN AREA (%) FIRST FLOOR SECOND FLOOR 1681 1681 1528 1437 153 244 9% 15% SOUTH ELEVATION TOTAL AREA (sf) TOTAL CLOSED AREA (sf) TOTAL OPEN AREA (sf) OPEN AREA (%) FIRST FLOOR SECOND FLOOR 1157 1157 574 710 583 447 50% 39% EAST ELEVATION TOTAL AREA (sf) TOTAL CLOSED AREA (sf) TOTAL OPEN AREA (sf) OPEN AREA (%) FIRST FLOOR SECOND FLOOR 1453 1453 1221 894 232 559 16% 25% TOTAL PERIMETER AREA TOTAL AREA (sf) TOTAL CLOSED AREA (sf) TOTAL OPEN AREA (sf) OPEN AREA (%) FIRST FLOOR SECOND FLOOR 5522 5522 4437 4157 1085 1365 20% 25% OPENING CALCULATIONS 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:57 AM G100 CODE ANALYSIS - FIRE SEPARATION DISTANCE 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1FIRE SCALE: 1/16" SEPERATION = 1'-0" DISTANCE 1 GMP / PERMIT SET 13 MAY 2016 20' TO LESS THAN 25' FIRE SEPARATION DISTANCE = 45% (UP, NS) 25' TO LESS THAN 30' FIRE SEPARATION DISTANCE = 70% (UP, NS) 30' OR GREATER FIRE SEPARATION DISTANCE = NO LIMIT (UP, NS) A. VALUES INDICATED AREA THE PERCENTAGE OF THE AREA OF THE EXTERIOR WALL, PER STORY. B. FOR THE REQUIREMENTS FOR FIRE WALLS OF BUILDINGS WITH DIFFERING HEIGHTS, SEE IBC SECTION 706.6.1. G. THE AREA OF OPENINGS IN AN OPEN PARKING STRUCTURE WITH A FIRE SEPARATION DISTANCE OF 10 FEET OR GREATER SHALL NOT BE LIMITED. COMMON PATH OF EGRESS TRAVEL (IBC 1014.3) GROUP S OCCUPANCY: OCCUPANT LOAD < 30 = 100 FEET MAXIMUM OCCUPANT LOAD > 30 = 75 FEET MAXIMUM GROUP M OCCUPANCY: 75 FEET MAXIMUM (NONSPRINKLERED) d. THE COMMON PATH OF EGRESS TRAVEL IN A GROUP S-2 OPEN PARKING GARAGE SHALL NOT BE MORE THAN 100 FEET DEAD END CORRIDORS (IBC 1018.4) EXCEPTION 3: A DEAD END CORRIDOR SHALL NOT BE LIMITED IN LENGTH WHERE THE LENGTH OF THE DEAD- END CORRIDOR IS LESS THAN 2.5 TIMES THE LEAST WIDTH OF THE DEAD-END CORRIDOR. MINIMUM NUMBER OF EXITS PER STORY (IBC TABLE 1021.1) OCCUPANCY LOAD (persons per story) MINIMUM NUMBER OF EXITS 1 - 500 2 EXITS 501 - 1000 3 EXITS MORE THAN 1000 4 EXITS DISTANCE BETWEEN EXITS (IBC 1015.2.1; EXC. 2) MINIMUM SEPARATION BETWEEN EXITS SHALL NOT BE LESS THAN 1/2 OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED EGRESS WIDTH PER OCCUPANT SERVED (NONSPRINKLERED) STAIRWAYS: 0.3 INCHES / OCCUPANT (TABLE 1005.1) OTHER EGRESS COMPONENTS: 0.15 INCHES / OCCUPANT (TABLE 1005.1) MINIMUM STAIRWAY WIDTH: 44" (IBC 1009.1) 36" <50 OCCUPANTS (IBC 1009.1;EXC. 1) MINIMUM RAMP WIDTH: SEE CORRIDOR WIDTH MINIMUM CORRIDOR WIDTH: 44" (IBC 1017.2) 36" <50 OCCUPANTS (IBC 1017.2 ;EXC. 2) 24" ACCESS TO AND UTILIZATION OF MEP SYSTEMS OR EQUIPMENT (IBC 1017.2 ;EXC.1) DOOR ENCROACHMENT: DOORS OPENING INTO PATH OF EGRESS TRAVEL SHALL NOT REDUCE THE REQUIRED WIDTH TO LESS THAN ONE-HALF DURING THE COURSE OF THE SWING. WHEN FULLY OPEN, THE DOOR SHALL NOT PROJECT MORE THAN 7 INCHES INTO THE REQUIRED WIDTH. (IBC 1005.2) DOORS, GATES AND TURNSTILES MINIMUM & MAXIMUM DOOR SIZES: 32" AND 48" CLEAR WIDTH, RESPECTIVELY (IBC 1008.1.1) DIRECTION OF SWING: IN DIRECTION OF EGRESS TRAVEL WHERE SERVING > 50 OCCUPANTS (IBC 1008.1.2) DOOR CLOSING: FIRE DOORS SHALL BE SELF- OR AUTOMATIC-CLOSING (IBC 716.5.7). LANDING WIDTH: NOT LESS THAN THE WIDTH OF THE STAIR OR THE DOOR, WHICHEVER IS GREATER. DOORS IN FULLY OPEN POSITION SHALL NOT REDUCE A REQUIRED DIMENSION BY MORE THAN 7 INCHES. AT LANDINGS SERVING AN OCCUPANT LOAD > 50, DOOR SWING SHALL LEAVE NOT LESS THAN ONE HALF OF THE REQUIRED WIDTH OF A LANDING. (IBC 1008.1.6) LANDING LENGTH: 44" MINIMUM IN DIRECTION OF TRAVEL. (IBC 1008.1.6) THRESHOLD HEIGHT: 1/2" MAXIMUM (IBC 1008.1.7) ELECTRICAL ROOMS: ELECTRICAL ROOMS WITH EQUIPMENT RATED 1,200 AMPERES OR MORE AND OVER 6 FEET WIDE THAT CONTAIN CURRENT DEVICES, SWITCHING DEVICES OR CONTROL DEVICES -- DOOR SHALL HAVE PANIC/FIRE EXIT HARDWARE AND SWING IN THE DIRECTION OF TRAVEL (IBC 1008.1.10) ACCESSIBLE MEANS OF EGRESS CODE SUMMARY, CONTINUED CODE SUMMARY, CONTINUED SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY (IBC TABLE 1015.1) OCCUPANCY MAX. OCC. LOAD GROUP S 29 GROUP M 49 ACCESSIBLE MEANS OF EGRESS REQUIRED SEPARATION BETWEEN BUILDINGS OR REFUGE AREAS CONNECTED BY A HORIZONTAL EXIT SHALL BE PROVIDED BY A FIRE WALL COMPLYING WITH IBC SECTION 706; OR IT SHALL BE PROVIDED BY A FIRE BARRIER COMPLYING WITH IBC SECTION 707 OR A HORIZONTAL ASSEMBLY COMPLYING WITH IBC SECTION 711, OR BOTH. OPENING PROTECTIVES IN HORIZONTAL ASSEMBLIES SHALL ALSO COMPLY WITH IBC SECTION 716. DUCT AND AIR TRANSFER OPENINGS IN A FIRE WALL OR FIRE BARRIER THAT SERVES AS A HORIZONTAL EXIT SHALL ALSO COMPLY WITH IBC SECTION 717. THE HORIZONTAL EXIT SEPARATION SHALL EXTEND VERTICALLY THROUGH ALL LEVELS OF THE BUILDING UNLESS FLOOR ASSEMBLIES HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN TWO-HOURS WITH NO UNPROTECTED OPENINGS (IBC SECTION 1025.2) DEFERRED SUBMITTALS (IBC 106.3.4.2) DOCUMENTS FOR DEFERRED SUBMITTAL SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. 1. FIRE ALARM SHOP SUBMITTAL. 2. PRECAST CONCRETE SHOP DRAWINGS. 3. GLAZED ALUMINUM CURTAIN WALL SHOP DRAWINGS. 4. METAL STAIRS AND MISC. ARCHITECTURAL METAL WORK, (INCLUDING HANDRAIL SHOP DRAWINGS). 5. ROOFING SYSTEMS CONFORMANCE TO WIND / DEFLECTION CRITERIA. 6. SPECIAL INSPECTIONS (IBC 1704). - STEEL CONSTRUCTION: WELDS, CUTS AND HIGH-STRENGTH BOLTING (IBC 1704.3). - CONCRETE CONSTRUCTION (IBC 1704.4). - MASONRY CONSTRUCTION (IBC 1704.5). - SOILS (IBC 1704.7). - PIERS (IBC 1704.9). - SPRAY FIRE RESISTANT MATERIALS (FIRE-PROOFING STEEL AND FLOORS). (IBC 1704.10). - SPECIAL CASES: AS DETERMINED BY THE CITY OF GREENVILLE BUILDING DEPARTMENT (IBC 1704.13). 7. CODE REQUIRED SIGNAGE, INCLUDING BUT NOT LIMITED TO: - ACCESSIBILITY PER IBC 1007 AND 1110. - DOORS PER IBC 1008. - ELEVATORS PER IBC 1109. - ASSEMBLY OCCUPANT CONTENT PER IBC 1004. - TACTILE EXIT SIGNAGE PER IBC 1011.3. - STAIR IDENTIFICATION PER IBC 1011, 1020 AND 1110. - STANDPIPE CONTROL PER IBC 905. GENERAL BUILDING CODE COMMENTS 1. A CERTIFICATE OF OCCUPANCY MUST BE OBTAINED BY THE TENANT PRIOR TO OCCUPYING ANY BUILDINGS OR PORTIONS OF BUILDINGS. 2. FIRE RESISTANCE RATINGS OF SHAFT ENCLOSURES SHALL COMPLY WITH IBC 707.4, BUT SHALL NOT BE LESS THAN THE FLOOR ASSEMBLY PENETRATED. 3. FIRE RESISTANCE RATINGS OF SHAFT ENCLOSURES SHALL COMPLY WITH IBC 707.4. 4. THE SUPPORTING CONSTRUCTION OF SHAFT ENCLOSURES SHALL BE PROTECTED TO AFFORD THE REQUIRED FIRE-RESISTANCE RATING OF THE ELEMENT SUPPORTED. 5. PENETRATIONS OTHER THAN THOSE NECESSARY FOR THE PURPOSE OF THE SHAFT SHALL NOT BE PERMITTED IN SHAFT ENCLOSURES. DUCTS SHALL NOT PENETRATE EXIT SHAFT ENCLOSURES. (RE: IBC 707.8.1 AND APPROPRIATE EXCEPTIONS). 6. SHAFTS THAT DO NOT EXTEND TO THE BOTTOM OF THE STRUCTURE SHALL COMPLY WITH IBC 707.11. 7. SHAFTS THAT DO NOT EXTEND TO THE UNDERSIDE OF THE FLOOR DECK SHALL COMPLY WITH IBC 707.12. 8. PENETRATION OF ALL FIRE RATED BARRIERS, PARTITIONS AND HORIZONTAL ASSEMBLIES SHALL COMPLY WITH IBC 712. 9. FOR FIRE RATED WALLS OR PARTITIONS, THE SURFACE AREA OF INDIVIDUAL METALLIC OUTLET OR SWITCH BOXES SHALL NOT EXCEED 16 SQ INCHES. THE AGGREGATE SURFACE OF THE BOXES SHALL NOT EXCEED 100 SQ INCHES PER 100 SF OF WALL SURFACE. BOXES LOCATED ON OPPOSITE SIDES OF WALLS OR PARTITIONS SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. (RE: IBC 712.3.2, EXCEPTIONS 1 AND 1.1). 10. MEMBRANE PENETRATIONS SHALL COMPLY WITH IBC 712.3.2. (SEE EXCEPTIONS FOR ELECTRICAL BOXES, ETC). 11. PENETRATIONS OF MEMBRANES THAT ARE PART OF A FIRE-RESISTANT RATED HORIZONTAL ASSEMBLY SHALL COMPLY WITH IBC 712.4. 12. PENETRATIONS OF HORIZONTAL ASSEMBLIES WITHOUT A FIRE RESISTANT RATING SHALL COMPLY WITH IBC 712.4.2. 13. EXTERIOR CURTAIN WALL / FLOOR INTERSECTIONS SHALL COMPLY WITH IBC 713.4. 14. OPENING PROTECTIVES SHALL COMPLY WITH IBC TABLE 715.4. 15. FIRE DOORS SHALL BE LABELED IN ACCORDANCE WITH IBC 715.4.5 THRU 715.4.5.1. 16. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE (11 LUX) AT THE FLOOR LEVEL. (RE: IBC 1006.1 AND 1006.2) 17. HANDRAILS SHALL COMPLY WITH IBC 1012.1 THRU 1012.8. GUARDS SHALL COMPLY WITH IBC 1013.1 THRU 1013.6 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCE - CHAPTER 4 ACCESSORY OCCUPANCIES (IBC 508.2) INCIDENTAL USE AREAS (IBC 509.2 & TABLE 509) OPEN PARKING GARAGE, IN ACCORDANCE WITH IBC SECTION 406.5, IS NOT REQUIRED TO BE EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (IBC SECTION 403.3, EXCEPTION). FIRE DETECTION SHALL COMPLY WITH IBC SECTION 907.2.13.1 (IBC SECTION 403.4.1). FIRE ALARM SHALL BE PROVIDED IN ACCORDANCE WITH IBC SECTION 907.2.13 (IBC SECTION 403.4.2). STANDBY POWER SYSTEM COMPLYING WITH CHAPTER 27 AND SECTION 3003 SHALL BE PROVIDED FOR STANDBY POWER LOADS INCLUDING POWER AND LIGHTING FOR FIRE COMMAND CENTER, VENTILATION AND AUTOMATIC FIRE DETECTION EQUIPMENT FOR SMOKE-PROOF ENCLOSURES, AND ELEVATORS. EMERGENCY POWER SYSTEM COMPLYING WITH CHAPTER 27 SHALL BE PROVIDED FOR EMERGENCY POWER LOADS INCLUDING EXIT SIGNAGE, MEANS OF EGRESS ILLUMINATION, ELEVATOR CAR LIGHTING, EMERGENCY VOICE/ALARM COMMUNICATIONS SYSTEMS, AUTOMATIC FIRE DETECTION SYSTEMS, FIRE ALARM SYSTEMS, AND ELECTRICALLY POWERED FIRE PUMPS. STANDBY POWER AND EMERGENCY POWER SHALL BE PROVIDED/INTERCONNECTED WITH HOTEL GENERATOR LUMINOUS EGRESS PATH MARKINGS SHALL BE PROVIDED IN ACCORDANCE WITH IBC SECTION 1024 (IBC SECTION 403.5.5). ELEVATOR INSTALLATION AND OPERATION SHALL COMPLY WITH CHAPTER 30 AND IBC SECTIONS 403.6.1 AND 403.6.2. NO FEWER THAN TWO FIRE SERVICE ACCESS ELEVATORS, OR ALL ELEVATORS, WHICHEVER IS LESS, SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 3007 AND HAVE A CAPACITY OF NOT LESS THAN 3500 POUNDS. WHERE INSTALLED IN ACCORDANCE WITH IBC SECTION 3008, PASSENGER ELEVATORS FOR GENERAL PUBLIC SHALL BE PERMITTED TO BE USED FOR PASSENGER SELF-EVACUATION (IBC SECTION 403.5.6). PUBLIC PARKING GARAGES - CHAPTER 4 CLEAR HEIGHT SHALL NOT BE LESS THAN 7 FEET ABOVE EACH FLOOR LEVEL (IBC SECTION 406.4.1) RAMPS USED FOR VERTICAL CIRCULATION AS WELL AS PARKING SHALL NOT EXCEED A 1:15 SLOPE (IBC SECTION 406.4.4). FLOORS SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO DRAINS OR VEHICLE ENTRY (IBC SECTION 406.4.5) MIXED OCCUPANCIES SHALL BE SEPARATED FROM OTHER OCCUPANCIES IN ACCORDANCE WITH IBC SECTION 508.1(IBC SECTION 406.4.6) OPEN PARKING GARAGES SHALL BE OF TYPE I, II OR IV CONSTRUCTION (IBC SECTION 406.5.1) OPENINGS SHALL COMPLY WITH IBC SECTION 406.5.2 A STANDPIPE SYSTEM SHALL BE PROVIDED PER IBC SECTION 905.3 (IBC SECTION 406.5.8) TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT SEPARATED OCCUPANCIES (TABLE 508.4) REQUIRED SEPARATION OF OCCUPANCES (HOURS) (IBC 508.2) OCCUPANCY S-2 B, M S-2 N N 1 2 B, M - - N N ACCESSORY OCCUPANCIES SHALL NOT OCCUPY MORE THAN 10 PERCENT OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED AND SHALL NOT EXCEED THE VALUES IN IBC TABLE 503, AND IN ACCORDANCE WITH IBC SECTION 506 (IBC SECTION 508.2) SECTION 510.8 GROUP B OR M WITH GROUP S-2 OPEN PARKING GARAGE GROUP B OR M OCCUPANCIES LOCATED NOT HIGHER THAN THE FIRST STORY ABOVE GRADE PLANE SHALL BE CONSIDERED AS A SEPERATE AND DISTINCT BUILDING FOR THE PURPOSE OF DETERMINING THE TYPE OF CONSTRUCTION WHERE ALL OF THE FOLLOWING CONIDITIONS ARE MET: 1. THE BUILDINGS ARE SEPERATED WITH A HORIZONTAL ASSEMBLY HAVING A FIRE RATING OF NOT LESS THAN 2 HOURS. 2. THE OCCUPANCIES IN THE BUILDING BELOW THE HORIZONTAL ASSEMBLY ARE LIMITED TO GROUPS B AND M. 3. THE OCCUPANCY ABOVE THE HORIZONAL ASSEMBLY IS LIMITED TO A GROUP S-2 OPEN PARKING GARAGE 4. THE BELING BELOW THE HORIZONTAL ASSEMBLY IS OF TYPE I OR II CONSTUCTION BUT NOT LESS THAN THE TYPE OF CONSTUCTION REQUIRED FOTH GROUP S-2 OPEN PARKING GARAGE ABOVE. 5. THE HEIGHT AND AREA OF THE BUILDING BELOW THE HORIZONTAL ASSEMBLY DOES NOT EXCEED THE LIMITS SET FORTH IN SECTION 503. 6. THE HEIGHT AND AREA OF THE GROUP S-2 OPEN PARKING GARAGE DOES NOT EXCEED THE LIMITS SET FORTH IN SECTION 405.5. THE HEIGHT, IN BOTH FEET AND STORIES OF THE GROUP S-2 OPEN PARKING GARAGE SHALL BE MEASURED FROM GRADE PLANE AND SHALL INCLUDE THE BUILDING BELOW THE HORIZONTAL ASSEMBLY. 7. EXITS SERVING THE GROUP S-2 OPEN PARKING GARAGE DISCHARGE DIRECTLY TO A STREET OR PUBLIC WAY AND ARE SEPERATED FROM THE BUILDING BELOW THE HORIZONTAL ASSEMBLY BY 2-HR FIRE BARRIERS CONSTRUCTED IN ACCORDANCE WITH SECTION 707 OR 2 HOUR HORIZONTAL ASSEMBLIES CONSTRUCTION IN ACCORDANCE WITH SECTION 711, OR BOTH. PRIMARY STRUCTURAL FRAME EXCLUSING COLUMNS GIRDERS, BEAMS, TRUSSES, & SPANDRELS 0 HOURS** STRUCTURAL COLUMNS 0 HOURS* BEARING WALLS EXTERIOR f, g 0 HOURS* INTERIOR 0 HOURS** NON-LOAD BEARING WALLS AND PARTITIONS EXTERIOR SEE BELOW TABLE 602 INTERIOR *a 0 HOURS FLOOR CONSTRUCTION INCLUDING SECONDARY MEMBERS 0 HOURS ROOF CONSTRUCTION INCLUDING SECONDARY MEMBERS 0 HOUR c* a. ROOF SUPPORTS: FIRE-RESISTANCE OF PRIMARY STRUCTURAL FRAME AND BEARING WALLS ARE PERMITTED TO BE REDUCED BY 1 HOUR WHERE SUPPORTING A ROOF ONLY. b. EXCEPT IN GROUP F-1, H, M AND S-1 OCCUPANCIES, FIRE PROTECTION OF STRUCTURAL MEMBERS SHALL NOT BE REQUIRED, INCLUDING PROTECTION OF ROOF FRAMING AND DECKING WHERE EVERY PART OF THE ROOF CONSTRUCTION IS 20 FEET OR MORE ABOVE ANY FLOOR IMMEDIATELY BELOW. FIRE-RETARDANT-TREATED OF EXTERIOR WALLS SHALL NOT BE PERMITTED. c. IN ALL OCCUPANCIES, HEAVY TIMBER SHALL BE ALLOWED WHERE A 1-HOUR OR LESS FIRE-RESISTANCE RATING IS REQUIRED. f. NOT LESS THAN THE FIRE-RESISTANCE RATING BASED ON FIRE SEPARATION DISTANCE (REFER TO IBC TABLE 602). g. NOT LESS THAN THE FIRE-RESISTANCE RATING AS REFERENCED IN SECTION 704.10. COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION COMBUSTIBLE MATERIALS SHALL BE PERMITTED AS NOTED IN IBC SECTION 603.1 AND IN ACCORDANCE WITH IBS SECTION 603.1.1 THROUGH 603.1.3. FIRE AND SMOKE PROTECTION FEATURES - CHAPTER 7 SECTION 705.5 FIRE RESISTANCE RATINGS EXTERIOR WALLS SAHLL BE FIRE RESISTANCE RATED IN ACCORDANCE WITH TABLES 601 AND 602 AND THIS SECTION. THE REQUIRED FIRE- RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPERATION DISTANCE GREATER THAN 10 FEET SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE. THE REQUIRED FIRE- RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPERATION DISTANCE OF LESS THAN OR EQUAL TO 10 FEET SHALL BE RATED FOR EXPOSURE TO FIRE FROM BOTH SIDES. AREA/OCCUPANT LOAD FACTOR OCCUPANT LOAD SPACE AREA/O.L. FACTOR OCCUPANT LOAD LEVEL 01 (GARAGE) 35952 SF / 200 SF 180 LEVEL 01 (MERCANTILE - RETAIL) 2650 SF / 30 SF 88 LEVEL 01 (MECHANICAL) 76 SF / 300 SF 1 LEVEL 01 (ELECTRICAL) 83 SF / 300 SF 1 LEVEL 01 (SERVER) 83 SF / 300 SF 1 LEVEL 01 (STORAGE) 1127 SF / 300 SF 4 TOTAL 39,971 SF 275 LEVEL 02 (GARAGE) 39607 / 200 SF 198 TOTAL 39,607 SF 198 LEVEL 03 (GARAGE) 39607 / 200 SF 198 TOTAL 39,607 SF 198 EXIT ACCESS TRAVEL DISTANCE (IBC TABLE 1016.2) OCCUPANCY WITHOUT SPRINKLER SYSTEM (feet) GROUP S-2 300 GROUP M 200 FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE - TYPE IB (TABLE 602) SEPARATION DISTANCE GROUP M GROUP A, B, R, & S-2g X < 5' FIRE SEPARATION DISTANCE 2 HOUR 1 HOURS d 5' ≤ X ≤ 10' FIRE SEPARATION DISTANCE 2 HOUR 1 HOUR d 10' ≤ X ≤ 30' FIRE SEPARATION DISTANCE 0 HOUR 0 HOUR d X > 30' FIRE SEPARATION DISTANCE 0 HOURS 0 HOURS d a. LOAD-BEARING EXTERIOR WALLS SHALL ALSO COMPLY WITH THE FIRE-RESISTANCE RATING REQUIREMENTS OF TABLE 601. c. REFER TO SECTION 706.1.1 FOR PARTY WALLS. d. OPEN PARKING GARAGES COMPLYING WITH SECTION 406 SHALL NOT BE REQUIRED TO HAVE A FIRE RESISTANCE RATING. e. THE FIRE-RESISTANCE RATING OF AN EXTERIOR WALL IS DETERMINED BASED ON THE FIRE SEPARATION DISTANCE OF THE EXTERIOR WALL AND THE STORY IN WHICH THE WALL IS LOCATED. h. WHERE IBC TABLE 705.8 PERMITS NON-BEARING EXTERIOR WALLS WITH UNLIMITED AREA OF UNPROTECTED OPENINGS, THE FIRE-RESISTANCE RATING FOR THE EXTERIOR WALLS IS 0 HOURS. TYPE OF CONSTRUCTION HEIGHT (IN TIERS) AREA PER TIER RAMP ACCESS AUTOMATIC SPRINKLER SYSTEM NO YES IB UNLIMITED 12 TIERS 12 TIERS 18 TIERS STAIRWAYS HEADROOM: MINIMUM 80" MEASURED VERTICALLY FROM A LINE CONNECTING THE EDGE OF THE NOSINGS (IBC 1009.5) STAIR TREADS AND RISERS: STAIR RISER HEIGHTS SHALL BE 7" MAXIMUM AND 4" MINIMUM. STAIR TREAD DEPTHS SHALL BE 11" MINIMUM. (IBC 1009.7) LANDINGS: PROVIDE FLOOR OR LANDING AT TOP AND BOTTOM OF EACH STAIR. LANDING WIDTH SHALL NOT BE LESS THAN WIDTH OF STAIRS BEING SERVED. LANDING SHALL HAVE A MINIMUM DIMENSION MEASURED IN THE DIRECTION OF TRAVEL EQUAL TO THE WIDTH OF THE STAIRWAY. (IBC 1009.8) VERTICAL RISE: MAXIMUM 12' BETWEEN FLOOR LEVELS OR LANDINGS (IBC 1009.10) STAIR TO ROOF: REQ'D IN BLDGS LOCATED FOUR OR MORE STORIES IN HEIGHT ABOVE GRADE PLANE. ROOFS NOT USED FOR HABITABLE PURPOSES SHALL PROVIDE ONE CONVENTIONAL STAIRWAY OR ONE ALTERNATING TREAD DEVICE (IBC 1009.16). SIGNAGE REQUIRED: EXIT SIGNAGE SHALL BE PROVIDED AT EACH EXIT STAIRWAY (IBC 1011.1, 1011.2, 1011.3, 1011.4, 1011.5, 1011.6) ELEVATORS AND ELEVATOR LOBBIES MACHINE ROOM VENTILATION SHALL BE CONNECTED TO STANDBY POWER SOURCE. (IBC 3003.1.4) TWO-WAY COMMUNICATION REQUIRED (IBC 1007.8) INTERIOR WALL AND CEILING FINSH REQUIREMENTS (SPRINKLERED) (IBC TABLE 803.9) SPACE TYPE B, M EXIT ENCLOSURES AND EXIT PASSAGEWAYS CLASS B CORRIDORS CLASS C ROOMS AND ENCLOSED SPACES CLASS PROVIDE FLAMESPREAD CERTIFICATION OF ALL FINISH MATERIALS IN COMPLIANCE WITH IBC 803.1. INTERIOR FLOOR FINISHES SHALL COMPLY WITH IBC 804. 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:51 AM G021 CODE SUMMARY 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 GMP / PERMIT SET 13 MAY 2016 PLAN, SECTION OR ELEVATION DETAIL OR ENLARGEMENT REFERENCE AREA X XXXX DETAIL SECTION REFERENCE DRAWING SYMBOLS SHEET NUMBER DRAWING NUMBER X WALL SECTION REFERENCE XXXX EXIT PATH 1 HOUR RATED ENCLOSURE 2 HOUR RATED ENCLOSURE PROPERTY LINE SHEET NUMBER DRAWING NUMBER DRAWING NUMBER X XXXX RE: X/A4XX UNIT TYPE UNIT IDENTIFICATION ENLARGED PLAN REFERENCE ABBREVIATIONS GENERAL NOTES LOCATION MAP PINE STREET LINDEN STREET CONCRETE CMU SAND / GROUT GYPSUM BOARD PLYWOOD DETAIL PLYWOOD BOARD INSULATION EARTH GRAVEL FINISH WOOD CONTINUOUS WOOD FRAMING PLASTIC CERAMIC TILE GLASS ALUMINUM BATT INSULATION WOOD BLOCKING SHIMS MATERIAL SYMBOLS BRICK STEEL STONE FIRE SAFING PARTICLE BOARD FOAMED-IN-PLACE INSULATION 1. SITEWORK 3. MASONRY 2. CONCRETE 5. WOOD 6. THERMAL 4. METAL 7. GLAZING 8. FINISHES CARPET 4240 ARCHITECTURE INC 3507 RINGSBY COURT SUITE 117 DENVER, CO 80216 t: 303.292.3388 f: 303.292.3113 ARCHITECT ISS. # copyright 2016 KEY PLAN DESCRIPTION DATE ARCHITECT'S PROJECT NUMBER SA MIRO, INC 4582 S. ULSTER ST PKWY STE 300 DENVER, CO 80237 t: 303.741.3737 f: 720.407.1635 STRUCTURAL MECHANICAL MKK CONSULTING ENGINEERS, INC ELECTRICAL PLUMBING CIVIL NORTHERN ENGINEERING, INC LANDSCAPE RUSSELL + MILLS STUDIOS PARKING WALKER PARKING CONSULTANTS 7600 E ORCHARD RD 250-S GREENWOOD, CO 80111 t: 303.796.6000 f: 303.796.6099 200 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.568.5415 f: 970.221.4159 5350 S ROSLYN ST GREENWOOD VILLAGE, CO 80111 t: 303.694.6622 141 S COLLEGE AVE FORT COLLINS, CO 80524 t: 970.484.8855 PARKING GARAGE WALNUT STREET 354, LLC OWNER 262 E MOUNTAIN AVE FORT COLLINS, CO 80524 t: 970.490.2626 5/13/2016 8:33:50 AM G011 GENERAL INFORMATION 165 CHESTNUT ST FORT COLLINS, CO 80524 21129.02 DOWNTOWN FORT COLLINS PARKING GARAGE 1 ALL WORK SHALL COMPLY WITH APPLICABLE FEDERAL, STATE, LOCAL AND ADOPTED CODES, ORDINANCES, REGULATIONS, LAWS, STATUTES, GUIDELINES AND REQUIREMENTS OF BUILDING AND FIRE AUTHORITIES HAVING JURISDICTION. 2 THE GENERAL CONTRACTOR (HEREAFTER "THE CONTRACTOR") AND SUBCONTRACTORS SHALL CAREFULLY STUDY ALL CONTRACT DOCUMENTS AND ACQUIRE A THOROUGH UNDERSTANDING OF THE DESIGN INTENT OF THE PROJECT AND THE DETAILS REQUIRED TO ACHIEVE THE DESIGN INTENT. 3 THE CONTRACTOR SHALL FORWARD REQUESTS FOR CLARIFICATION OR ADDITIONAL INFORMATION WITH REGARD TO ACHIEVING THE DESIGN INTENT OF THE PROJECT TO THE ARCHITECT IN WRITING FOR REVIEW AND WRITTEN RESPONSE. 4 THE CONTRACTOR SHALL CHECK AND VERIFY THE CONTRACT DOCUMENTS WITH FIELD CONDITIONS, CONFIRMING THAT ALL WORK IS BUILDABLE AS SHOWN, PRIOR TO PROCEEDING WITH THE WORK AND VERIFY ALL SPACE DIMENSIONS AS SHOWN WITH EXISTING JOB CONDITIONS BEFORE STARTING CONSTRUCTION. IF DISCREPANCIES EXIST, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING PRIOR TO COMMENCEMENT OF WORK. 5 PRICING OF THESE CONTRACT DOCUMENTS SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO CONSTRUCT THE PROJECT IN ACCORDANCE WITH THE DESIGN INTENT DESCRIBED THEREIN. 6 THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS AND SLEEVES THROUGH FLOORS, CEILINGS, ROOFS, WALLS, STRUCTURAL MEMBERS AND ARCHITECTURAL ELEMENTS WITH CIVIL, LANDSCAPE, ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL AND OTHER DISCIPLINES DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS. 7 THE CONTRACTOR SHALL PROTECT ALL IN-PLACE CONSTRUCTION, LANDSCAPING, PAVING, UTILITIES, ETC. FROM DAMAGE DURING CONSTRUCTION. ALL DAMAGED AREAS AND ITEMS SHALL BE RESTORED TO ORIGINAL CONDITION BY THE CONTRACTOR OR SUBCONTRACTOR DAMAGING THE SAME. 8 THE CONTRACTOR SHALL SUBMIT PROPOSED SUBSTITUTIONS OF SPECIFIED MATERIALS/ PRODUCTS TO THE ARCHITECT FOR REVIEW, IN ACCORDANCE WITH PROCEDURES DESCRIBED IN THE SPECIFICATIONS. 9 THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, CUT-SHEETS, AND SAMPLES WHEN REQUIRED BY THE SPECIFICATIONS, FOR REVIEW BY THE ARCHITECT, PRIOR TO COMMENCING WITH RELATED WORK. 10 ALL WORK SHALL BE ERECTED PLUMB, LEVEL AND TRUE-TO-LINE IN ACCORDANCE WITH BEST PRACTICES OF THE TRADE, MANUFACTURER'S INSTRUCTIONS FOR THE PARTICULAR PRODUCT, AND IN ACCORDANCE WITH THE SPECIFICATIONS. 11 THE CONTRACTOR SHALL NOTIFY ALL APPLICABLE LOCAL GOVERNMENTAL AGENCIES WHEN THERE IS A NEED FOR AN INSPECTION REQUIRED BY THE APPLICABLE CODE, OR BY THE AUTHORITY HAVING JURISDICTION. 12 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ALL PERSONNEL AND OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE OSHA REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED TO THE OWNER. 13 DO NOT SCALE DRAWINGS. 14 INTERIOR PARTITIONS ARE DIMENSIONED TO FACE OF GYPSUM BOARD, UNLESS INDICATED OTHERWISE. 15 THE INSIDE FACE OF DOOR JAMBS SHALL BE 4" FROM ADJACENT WALL OR FINISHED COLUMN, UNLESS INDICATED OTHERWISE. 16 WHERE NEW WORK HAS DISTURBED PREVIOUSLY INSTALLED OR EXISTING WORK OR FINISHES, SUCH AREAS SHALL BE REWORKED AND/OR REFINISHED AS REQUIRED TO MATCH THE ORIGINAL CONDITION OF THE AREA PRIOR TO THE DISTURBANCE. 17 EACH MISCELLANEOUS ITEM OF CUTTING, PATCHING OR FITTING IS NOT NECESSARILY INDIVIDUALLY DESCRIBED IN THE DOCUMENTS. THE ABSENCE OF SPECIFIC DESCRIPTIONS OF CUTTING, PATCHING, OR FITTING REQUIRED TO PROPERLY ACCOMMODATE THE SCOPE OF WORK SHALL NOT RELIEVE THE CONTRACTOR OR SUBCONTRACTOR FROM THE RESPONSIBILITY TO PERFORM SUCH WORK AS REQUIRED TO ACHIEVE THE DESIGN INTENT OF THE PROJECT. 18 NOTES APPEAR ON DIFFERENT SHEETS FOR DIFFERENT SYSTEMS AND CONSTRUCTION MATERIAL. ALL SHEETS ARE TO BE REVIEWED AND NOTES ON ANY ONE SHEET ARE TO BE APPLIED TO ALL RELATED DRAWINGS AND DETAILS. 19 DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER AND QUALITY TO THOSE DETAILED. WHERE SPECIFIED DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR CLARIFICATION, PRIOR TO PROCEEDING WITH WORK. 20 ALL EXTERIOR SOFFITS SHALL BE CONSTRUCTED WITH RIGID FRAME MEMBERS AND SHALL RESIST UPLIFTING WIND LOADS OF AT LEAST 1.5 TIMES WIND PRESSURES. 21 ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER TO AVOID GALVANIC ACTION. 22 A FINISH OR FIRE RATING ON A WALL SHALL MEAN THE ENTIRE LENGTH AND HEIGHT OF WALL TO BE FINISHED OR FIRE RATED, AS INDICATED. 23 THE HEAD AND BASE CONDITIONS OF ALL FIRE RATED WALLS SHALL BE TERMINATED WITH UL-APPROVED DESIGNS AND MATERIALS. 24 SCOPES OF WORK ON THE DRAWINGS NOTED AS "NIC" ARE" NOT INCLUDED IN CONTRACT. 25 ALL FLOOR ELEVATIONS ARE TO TOP OF STRUCTURAL CONCRETE OR TOPPING SLAB UNLESS INDICATED OTHERWISE. 26 PROVIDE BLOCKING OR OTHER SUPPORT AS REQUIRED FOR ALL WALL, FLOOR, CEILING AND ROOF MOUNTED ITEMS. BLOCKING SHALL BE FIRE RESISTIVE TREATED AS REQUIRED AND PERMITTED BY CODE. 27 SHOULD ANY CONFLICT OCCUR BETWEEN THE ARCHITECTURAL DRAWINGS AND THE ARCHITECT'S CONSULTANTS' DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR CLARIFICATION. 28 COORDINATE PLACEMENT OF ALL CEILING ELEMENTS WITH MECHANICAL, ELECTRICAL, FIRE PROTECTION, EQUIPMENT AND OTHER INSTALLERS. WHERE DISCREPANCIES EXIST BETWEEN DRAWINGS AND FIELD CONDITIONS, CONSULT THE ARCHITECT PRIOR TO PROCEEDING WITH INSTALLATION. 29 REFER TO PLUMBING DRAWINGS FOR LOCATIONS OF ALL FLOOR DRAINS, TRENCH DRAINS, SUMPS AND SUBSOIL DRAINAGE, UNLESS INDICATED OTHERWISE. IF LOCATIONS CONFLICT WITH ARCHITECTURAL DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR CLARIFICATION. 30 ALL PENETRATIONS OF DUCTWORK, CONDUIT, PIPING AND OTHER WORK THROUGH FIRE RATED ASSEMBLIES SHALL BE SEALED WITH UL-APPROVED DESIGNS AND MATERIALS TO MAINTAIN THE RATING OF THE ASSEMBLY. 31 ALL EQUIPMENT INSTALLED IN RETURN AIR PLENUMS SHALL BE APPROVED BY THE AUTHORITY HAVING JURISDICTION AGENCY FOR COMPLIANCE WITH CODE. 32 THE CONTRACTOR SHALL COORDINATE ALL EQUIPMENT BASE AND HOUSEKEEPING PADS WITH MECHANICAL, PLUMBING AND ELECTRICAL CONTRACTORS. EQUIPMENT BASE AND HOUSEKEEPING PADS TO BE MINIMUM 4" HIGH AND TO BE INSTALLED BENEATH THE PROJECTED AREA OF THE EQUIPMENT, AND IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. 33 SEE STRUCTURAL DRAWINGS FOR EXACT LOCATION, SIZE AND THICKNESS OF ALL STRUCTURAL ELEMENTS. IF STRUCTURAL DRAWINGS CONFLICT WITH ARCHITECTURAL DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR CLARIFICATION PRIOR TO PROCEEDING WITH WORK. MTL METAL MR MOISTURE RESISTANT MWP METAL WALL PANEL NA NOT APPLICABLE NIC NOT IN CONTRACT NTS NOT TO SCALE NO / # NUMBER O.C. ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OFOI OWNER FURNISHED, OWNER INSTALLED OPP OPPOSITE HAND ORD OVERFLOW ROOF DRAIN PC PRECAST CONCRETE PLAM PLASTIC LAMINATE PLUMB PLUMBING PLYWD PLYWOOD PN PROJECT NORTH PT PRESSURE TREATED PTD PAINTED RRADIUS RB RUBBER BASE RCP REFLECTED CEILING PLAN RD ROOF DRAIN RE: REFER TO REQ'D REQUIRED R.O. ROUGH OPENING ROW RIGHT OF WAY RS ROUGH SAWN SC SOLID CORE SHT SHEET SIM SIMILAR SIP STRUCTURAL INSULATED PANEL SS STAINLESS STEEL STD STANDARD STL STEEL STRUC STRUCTURE (STRUCTURAL) T TRANSFORMER TG TEMPERED GLASS T.O. TOP OF T.O.B. TOP OF BEAM T.O.D. TOP OF DECK T.O.R.D. TOP OF ROOF DECK T.O.F.D. TOP OF FLOOR DECK T.O.F.F. TOP OF FINISH FLOOR T.O.C. TOP OF CONCRETE T.O.P. TOP OF PARAPET T.O.R. TOP OF RAIL T.O.S. TOP OF STRUCTURE TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VERT VERTICAL VIF VERIFY IN FIELD W/ WITH WD WOOD W.O. WHERE OCCURS W/O WITHOUT WP WATERPROOFING WWF WELDED WIRE FABRIC CFMF COLD-FORMED METAL FRAMING ACT ACOUSTICAL CEILING TILE AES ARCHITECTURAL EXPOSED STEEL AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM BLDG BUILDING CIP CAST-IN-PLACE CG CORNER GUARD CJ CONSTRUCTION JOINT CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT C.O. CENTER OF C.O.F. CENTER OF FLUE COL COLUMN CONC CONCRETE C.O.W. CENTER OF WALL CT CERAMIC TILE CPT CARPET DD DESIGN DEVELOPMENT DIA DIAMETER DJ DEFLECTION JOINT DS DOWNSPOUT DWG DRAWING (E) EXISTING EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EPS EXPANDED POLYSTYRENE EQ EQUAL FD FLOOR DRAIN FEC FIRE EXTINGUISHER CABINET FH FINISH HEIGHT FIN FINISH FF FINISH FLOOR FR FIRE RESISTANT FRP FIBER REINFORCED PLASTIC FRT FIRE RETARDANT TREATED F.O. FACE OF FVC FIRE VALVE CABINET FXT FIXTURE GALV GALVANIZED GWB GYPSUM WALL BOARD GC GENERAL CONTRACTOR GFRC GLASS FIBER REINFORCED CONCRETE HC HANDICAPPED ACCESSIBLE HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HP HIGH POINT HT HEIGHT ID INTERIOR DESIGN ISS ISSUE LP LOW POINT MACH MACHINED MDF MEDIUM DENSITY FIBERBOARD MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM 1 GMP / PERMIT SET 13 MAY 2016 G203 CODE ANALYSIS - EGRESS & TRAVEL DISTANCE O G351 DETAILS - ACCESSIBILITY MOUNTING HEIGHTS O 4 ARCHITECTURAL A001 SITE PLAN O A101 FLOOR PLAN LEVEL 1 O A102 FLOOR PLAN LEVEL 2 O A103 FLOOR PLAN LEVEL 3 O A104 ROOF PLAN O A200 GARAGE ELEVATIONS O A250 BUILDING SECTIONS O A301 ENLARGED ELEVATIONS AND SECTIONS O A302 ENLARGED ELEVATIONS AND SECTIONS O A303 ENLARGED ELEVATIONS AND SECTIONS O A304 ENLARGED ELEVATIONS AND SECTIONS O A305 ENLARGED ELEVATIONS AND SECTIONS O A306 ENLARGED ELEVATIONS AND SECTIONS O A307 ENLARGED ELEVATIONS AND SECTIONS O A308 ENLARGED ELEVATIONS AND SECTIONS O A309 ENLARGED ELEVATIONS AND SECTIONS O A500 EXTERIOR WALL ASSEMBLIES O A501 EXTERIOR WALL ASSEMBLIES O A510 STOREFRONT TYPES O A511 SCREEN TYPES AND DETAILS O A520 DOOR & FRAME TYPES & DOOR SCHEDULE O A601 FOUNDATION DETAILS O A602 PLAN DETAILS O A603 PLAN DETAILS O A604 SECTION DETAILS O A605 SECTION DETAILS O A606 SECTION DETAILS O A701 STAIR TOWER PLANS AND SECTIONS O A702 STAIR TOWER PLANS AND SECTIONS O A703 STAIR DETAILS O 5 STRUCTURAL S000 COVER O S001 STRUCTURAL GENERAL NOTES O S002 STRUCTURAL GENERAL NOTES O S003 STRUCTURAL GENERAL NOTES O S101 FOUNDATION PLAN O S102 LEVEL 2 FRAMING PLAN O S103 LEVEL 3 FRAMING PLAN O S103.5 LEVEL 3.5 FRAMING PLAN O S201 FOUNDATION DETAILS O S202 FOUNDATION DETAILS O S203 FOUNDATION DETAILS O S301 PRECAST GARAGE DETAILS O S302 PRECAST GARAGE DETAILS O S310 FRAMING DETAILS O S401 STAIR TOWER PLANS O S411 RAMP WALL ELEVATIONS O 6 MECHANICAL M000 MECHANICAL COVER SHEET O M101 MECHANICAL PLAN LEVEL 1 O M103 MECHANICAL PLAN LEVEL 3 O M401 MECHANICAL CONTROLS O M501 MECHANICAL SCHEDULES O 7 PLUMBING P101 PLUMBING PLAN LEVEL 1 O P102 PLUMBING PLAN LEVEL 2 O P103 PLUMBING PLAN LEVEL 3 O P401 PLUMBING DETAILS O P501 PLUMBING SCHEDULES O 8 ELECTRICAL E000 ELECTRICAL COVER SHEET O E101 LIGHTING PLAN LEVEL 1 O E102 LIGHTING PLAN LEVEL 2 O E103 LIGHTING PLAN LEVEL 3 O E201 POWER AND SYSTEMS PLAN LEVEL 1 O E202 POWER AND SYSTEMS PLAN LEVEL 2 O E203 POWER AND SYSTEMS PLAN LEVEL 3 O E401 ELECTRICAL ONE-LINE DIAGRAM O E501 LUMINAIRE SCHEDULES & COMCHECK O E502 ELECTRICAL SCHEDULES O E601 ELECTRICAL DETAILS O 9 STRIPING AND SIGNAGE PK101 FLOOR PLAN LEVEL 1 O PK102 FLOOR PLAN LEVEL 2 O PK103 FLOOR PLAN LEVEL 3 O PK601 STRIPING AND PARCS DETAILS O PK610 SIGN SCHEDULE AND DETAILS O PK611 SIGN DETAILS O PK620 SIGN MOUNTING DETAILS O 1 GMP / PERMIT SET 13 MAY 2016