HomeMy WebLinkAboutWORK ORDER - BID - 7658 MISCELLANEOUS CONCRETE ANNUAL (48)Estimate
Date
10/3/2016
Estimate #
305
Name / Address
BANNER CONCRETE LLC
715 Peterson Street
Fort Collins, CO 80524
bannerconcrete@gmail.com
Accounting:970-219-1026
Project
Customer Signature
Total
Description Qty Cost Total
Remington Eco-Totem,Foundation
Foundation 1 2,150.00 2,150.00
Traffic Control 1 1,200.00 1,200.00
_____________________________________
$3,350.00
Estimate
Date
10/3/2016
Estimate #
306
Name / Address
BANNER CONCRETE LLC
715 Peterson Street
Fort Collins, CO 80524
bannerconcrete@gmail.com
Accounting:970-219-1026
Project
Customer Signature
Total
Description Qty Cost Total
Remington Eco-Totem, Curb and paving
Medium cover-4" San Diego Buff per sq ft 160 9.87 1,579.20
Barrier curb-epoxy per lf 71 21.94 1,557.74
Reinforcing steel per pound 190 2.19 416.10
Aggregate base course/Recycled concrete base <5 tons 4 42.77 171.08
Concrete nosing 1 250.00 250.00
Traffic control 1 1,600.00 1,600.00
_____________________________________
$5,574.12
36 in
3 in
FLUSH IN GRADE SERVICE ENTRANCE SPLICE BOX.
EXISTING UTILITY SPLICE BOX.
POWER SUPPLY FLUSH IN GRADE VAULT BY Q-TRAN.
NEW POLYMER CONCRETE COMMUNICATIONS FLUSH IN-GRADE SPLICE
BOX WITH TRAFFIC RATED TIER 22 COVER, 18" x 11" x 12" DP.
CONTRACTOR TO SAW-CUT ZELT INDUCTIVE LOOP IN ROADWAY.
LEGEND:
C
P
S
U
C
1" BORED HDPE
CONDUIT ACROSS
REMINGTON.
EXISTING ROADWAY LUMINAIRE
ZELT INDUCTIVE LOOP
1" HDPE CONDUIT
POWER SUPPLY IN
VAULT
(2#10 THWN CU & 1#10 GND) 3/4" PVC
FROM PEDESTRIAN LUMINAIRE
CIRCUIT, TO POWER SUPPLY.
24" TRENCH, BURY, BACKFILL AND
RETURN LANDSCAPE TO
PRE-CONSTRUCTION CONDITION.
(2#10 THWN CU &
1#10 THWN GND) 3
4" C.
BLOCK-OUT IN CURB TO
ALLOW ZELT CABLE INTO
SAW-CUT IN ROADWAY
PAVEMENT.
BLOCK-OUT IN CURB TO ALLOW
ZELT CABLE INTO SAW-CUT IN
ROADWAY PAVEMENT.
SPLICE BOX EXCAVATED
IN EXISTING TREE LAWN.
E LAKE STREET
ECO
CONCRETE BULB OUT
REMINGTON ST.
ECO TOTEM
ZELT INDUCTIVE LOOP
P C
1" HDPE CONDUIT
WITH ZELT CABLE
S
(2#8 THWN CU) 3/4" PVC
U
C
1" PVC CONDUIT TRENCHED OR
BORED HDPE CONDUIT ALONG
SIDEWALK. RETURN LANDSCAPE TO
PRE-CONSTRUCTION CONDITION.
SPLICE BOX EXCAVATED
ADJACENT TO EXISTING SIDEWALK.
RETURN LANDSCAPE TO
PRE-CONSTRUCTION CONDITION.
Sheet Date:
3/4" x 10'-0" COPPER CLAD
DRIVEN GROUND ROD.
PROVIDE 1#6 S.D.B.C.
EXOTHERMIC WELDED OR
UNDERGROUND RATED LUG
CONNECT CONDUCTOR TO
GROUND ROD.
ECO TOTEM FOUNDATION,
SEE SITE PLAN.
6"
MIN
EXISTING
TREE LAWN
AREA
(TYPICAL)
P
SEE ECO TOTEM
INSTALLATION FOR
FOUNDATION CONDUIT
AND BOLT PATTERN
INFORMATION (TYPICAL)
C
1" BORED HDPE
CONDUIT ACROSS
REMINGTON TO ZELT
INDUCTIVE LOOP ON
N.B. SIDE.
SAW-CUT THROUGH ROADWAY
PAVEMENT TO INSTALL SPLICE BOX.
(TYPICAL)
SAW-CUT THROUGH
ROADWAY PAVEMENT
CONCRETE BULB OUT
CURB.
BLOCK-OUT IN CURB
TO ALLOW ZELT CABLE
IN CURB-CUT IN
ROADWAY PAVEMENT.
30"
15"
ROUTE GROUND WIRE
TO GROUND LUG IN ECO
TOTEM
DRAIN PIPE
CONTRACTOR SHALL MULTI-METER TEST EXISTING CIRCUIT AT PEDESTRIAN LUMINAIRE SPLICE BOX PRIOR TO
ORDERING Q-TRAN POWER SUPPLY TO RECORD THE EXISTING VOLTAGE.
CONTRACTOR SHALL EXCAVATE A 15" W x30" L x30" D HOLE FOR THE POWER SUPPLY FLUSH IN-GRADE VAULT. AFTER
BOX IS SET TO HEIGHT, LEVEL TO NEW CONCRETE BULB -OUT AND CONDUITS ARE INSTALLED BACKFILL WITH
PEA-GRAVEL/ DIRT MIXTURE TO PROMOTE DRAINAGE. INSTALL DRAIN PIPE AT LOWER SLOPE FOR PROPER DRAINAGE.
CONTRACTOR SHALL PROVIDE AND INSTALL A 120V PRI. TO 24VAC SEC. POWER SUPPLY WITH PRIMARY AND
SECONDARY BREAKERS Q-TRAN PRODUCT NUMBER = QSET-120-120/24. AND FLUSH IN CONCRETE VAULT BOX
#Q-VALT-5+SC+CR.
DETAIL NOTES:
GRAVEL
BED
3/4"
PVC
1
2
3
2
3
1
1" PVC 1" PVC
3/4" x 10'-0" COPPER
CLAD DRIVEN GROUND
ROD. PROVIDE 1#6
S.D.B.C. EXOTHERMIC
WELDED OR
UNDERGROUND RATED
LUG CONNECT
CONDUCTOR TO
GROUND ROD.
ROUTE GROUND
WIRE TO GROUND
LUG
INCOMING POWER
IN 3/4" PVC FROM
EXISTING UTILITY
SPLICE BOX.
NEW 11" x 18" x 12" DP. TIER 22 POLYMER CONCRETE, FLUSH IN-GRADE SERVICE ENTRANCE BOX.
(3) LUG, UNDERGROUND RATED TERMINAL BLOCK, ILSOC # PED3-3350SSP OR APPROVED EQUAL.
INLINE NON-BREAKAWAY, SUBMERSIBLE FUSE HOLDER WITH 15A FUSE. BUSSMANN #HEB-JJ & BAF 15 FUSE OR
APPROVED EQUAL.
5
6
4
4
5
6
COIL 5'-0" OF
CONDUCTORS IN THIS BOX
FOR FINAL CONNECTION
BY F.C. L & P FORCES.
EXISTING F.C. L & P UTILITY
SPLICE BOX. IN TREE LAWN.
(2#8 THWN CU)
3/4" PVC
H N H
G N
G
U
S
LOAD CALCULATION
ECO BIKE TOTEM
NEC DEMAND FACTOR 25 %
139/120 = 1.16 AMP @ 120V
= 111 VA
= 28 VA
139 VA
ALL OF THIS
EQUIPMENT IS IN THE
CONCRETE BULB OUT.
FLUSH IN-GRADE
HAND HOLE/
SPLICE BOX.
ZELT CABLE TO HAVE 8X TURNS
IN ZELT LOOP DIAMOND. (TYP.)
MINIMUM 30 TWIST PER YARD
COPPER, STRANDED WIRE,
ZELT CABLE.
16"
43" TO 60"
SIZE TO FIT BIKE LANE
POLYMER
CONCRETE
BOX. C
1/4" TO 1/2" WIDE X 2" DEEP
SAW-CUT ZELT LOOP DIAMOND.
THE DIAMOND SHAPE MUST BE
PERFECT.
EXISTING CURB OR NEW
CONCRETE BULB-OUT CURB.
EXISTING ROADWAY PAVEMENT
BIKE LANE LINE
CONDUIT ROUTED
IN CONCRETE
BULB-OUT OR
BORE ACROSS
REMINGTON TO
ECO TOTEM.
BLOCK-OUT IN CURB
TO ALLOW ZELT
CABLE INTO SAW-CUT
IN ROADWAY
PAVEMENT. SAW-CUT
IN CONDUIT EXISTING
CURB.
2"
1/4" TO 1/2"
MICRO-CEMENT TO SEAL
ROADWAY PAVEMENT
FOAM
8X TURNS OF ZELT CABLE
Sheet Date:
Sheet Number:
Drawing Name:
Drawn by:
Designed by:
Revisions
1603 Oakridge Drive
Fort Collins, CO 80525
(970) 223-7577
fax (970) 223-1827
Landscape Architecture
Urban Design
Graphic Design
Checked by:
NORTH
0
SCALE:
Project Number:
Project:
Client:
REMINGTON GREENWAY
CITY OF FORT COLLINS
ECO TOTEM
ELECTRICAL PLAN
15075
10.30.2015
E02
1" = 10'
5' 10' 20'
DR
GF
NC
lighting design and engineering
ECO TOTEM ELECTRICAL DETAIL
ZELT INDUCTIVE LOOP DETAIL
Sheet Number:
Drawing Name:
Drawn by:
Designed by:
Revisions
1603 Oakridge Drive
Fort Collins, CO 80525
(970) 223-7577
fax (970) 223-1827
Landscape Architecture
Urban Design
Graphic Design
Checked by:
NORTH
0
SCALE:
Project Number:
Project:
Client:
REMINGTON GREENWAY
CITY OF FORT COLLINS
ECO TOTEM
ELECTRICAL PLAN
15075
10.30.2015
E01
1" = 10'
5' 10' 20'
DR
GF
NC
ECO TOTEM ELECTRICAL PLAN
lighting design and engineering
FORT COLLINS LIGHT & POWER (F.C. L & P ) EXISTING UTILITY SPLICE BOX ADJACENT TO F.C. L & P'S ROADWAY
LUMINAIRE. COIL 5'-0" OF CONDUCTORS. FINAL CONNECTION BY F.C. L & P FORCES.
CONTRACTOR SHALL EXCAVATE A 15" W x30" L x30" D HOLE FOR THE POWER SUPPLY FLUSH IN-GRADE VAULT. AFTER
BOX IS SET TO HEIGHT, LEVEL TO NEW CONCRETE BULB -OUT AND CONDUITS ARE INSTALLED BACKFILL WITH
PEA-GRAVEL/ DIRT MIXTURE TO PROMOTE DRAINAGE. INSTALL DRAIN PIPE AT LOWER SLOPE FOR PROPER DRAINAGE.
CONTRACTOR SHALL PROVIDE AND INSTALL A 120V PRI. TO 24VAC SEC. POWER SUPPLY WITH PRIMARY AND
SECONDARY BREAKERS Q-TRAN PRODUCT NUMBER = QSET-120-120/24. AND FLUSH IN CONCRETE VAULT BOX
#Q-VALT-5+SC+CR.
NEW 11" x 18" x 12" DP. TIER 22 POLYMER CONCRETE, FLUSH IN-GRADE SERVICE ENTRANCE BOX.
PLAN NOTES:
2
3
1
1
2 3
4
4