Loading...
HomeMy WebLinkAboutWORK ORDER - BID - 7658 MISCELLANEOUS CONCRETE ANNUAL (48)Estimate Date 10/3/2016 Estimate # 305 Name / Address BANNER CONCRETE LLC 715 Peterson Street Fort Collins, CO 80524 bannerconcrete@gmail.com Accounting:970-219-1026 Project Customer Signature Total Description Qty Cost Total Remington Eco-Totem,Foundation Foundation 1 2,150.00 2,150.00 Traffic Control 1 1,200.00 1,200.00 _____________________________________ $3,350.00 Estimate Date 10/3/2016 Estimate # 306 Name / Address BANNER CONCRETE LLC 715 Peterson Street Fort Collins, CO 80524 bannerconcrete@gmail.com Accounting:970-219-1026 Project Customer Signature Total Description Qty Cost Total Remington Eco-Totem, Curb and paving Medium cover-4" San Diego Buff per sq ft 160 9.87 1,579.20 Barrier curb-epoxy per lf 71 21.94 1,557.74 Reinforcing steel per pound 190 2.19 416.10 Aggregate base course/Recycled concrete base <5 tons 4 42.77 171.08 Concrete nosing 1 250.00 250.00 Traffic control 1 1,600.00 1,600.00 _____________________________________ $5,574.12 36 in 3 in FLUSH IN GRADE SERVICE ENTRANCE SPLICE BOX. EXISTING UTILITY SPLICE BOX. POWER SUPPLY FLUSH IN GRADE VAULT BY Q-TRAN. NEW POLYMER CONCRETE COMMUNICATIONS FLUSH IN-GRADE SPLICE BOX WITH TRAFFIC RATED TIER 22 COVER, 18" x 11" x 12" DP. CONTRACTOR TO SAW-CUT ZELT INDUCTIVE LOOP IN ROADWAY. LEGEND: C P S U C 1" BORED HDPE CONDUIT ACROSS REMINGTON. EXISTING ROADWAY LUMINAIRE ZELT INDUCTIVE LOOP 1" HDPE CONDUIT POWER SUPPLY IN VAULT (2#10 THWN CU & 1#10 GND) 3/4" PVC FROM PEDESTRIAN LUMINAIRE CIRCUIT, TO POWER SUPPLY. 24" TRENCH, BURY, BACKFILL AND RETURN LANDSCAPE TO PRE-CONSTRUCTION CONDITION. (2#10 THWN CU & 1#10 THWN GND) 3 4" C. BLOCK-OUT IN CURB TO ALLOW ZELT CABLE INTO SAW-CUT IN ROADWAY PAVEMENT. BLOCK-OUT IN CURB TO ALLOW ZELT CABLE INTO SAW-CUT IN ROADWAY PAVEMENT. SPLICE BOX EXCAVATED IN EXISTING TREE LAWN. E LAKE STREET ECO CONCRETE BULB OUT REMINGTON ST. ECO TOTEM ZELT INDUCTIVE LOOP P C 1" HDPE CONDUIT WITH ZELT CABLE S (2#8 THWN CU) 3/4" PVC U C 1" PVC CONDUIT TRENCHED OR BORED HDPE CONDUIT ALONG SIDEWALK. RETURN LANDSCAPE TO PRE-CONSTRUCTION CONDITION. SPLICE BOX EXCAVATED ADJACENT TO EXISTING SIDEWALK. RETURN LANDSCAPE TO PRE-CONSTRUCTION CONDITION. Sheet Date: 3/4" x 10'-0" COPPER CLAD DRIVEN GROUND ROD. PROVIDE 1#6 S.D.B.C. EXOTHERMIC WELDED OR UNDERGROUND RATED LUG CONNECT CONDUCTOR TO GROUND ROD. ECO TOTEM FOUNDATION, SEE SITE PLAN. 6" MIN EXISTING TREE LAWN AREA (TYPICAL) P SEE ECO TOTEM INSTALLATION FOR FOUNDATION CONDUIT AND BOLT PATTERN INFORMATION (TYPICAL) C 1" BORED HDPE CONDUIT ACROSS REMINGTON TO ZELT INDUCTIVE LOOP ON N.B. SIDE. SAW-CUT THROUGH ROADWAY PAVEMENT TO INSTALL SPLICE BOX. (TYPICAL) SAW-CUT THROUGH ROADWAY PAVEMENT CONCRETE BULB OUT CURB. BLOCK-OUT IN CURB TO ALLOW ZELT CABLE IN CURB-CUT IN ROADWAY PAVEMENT. 30" 15" ROUTE GROUND WIRE TO GROUND LUG IN ECO TOTEM DRAIN PIPE CONTRACTOR SHALL MULTI-METER TEST EXISTING CIRCUIT AT PEDESTRIAN LUMINAIRE SPLICE BOX PRIOR TO ORDERING Q-TRAN POWER SUPPLY TO RECORD THE EXISTING VOLTAGE. CONTRACTOR SHALL EXCAVATE A 15" W x30" L x30" D HOLE FOR THE POWER SUPPLY FLUSH IN-GRADE VAULT. AFTER BOX IS SET TO HEIGHT, LEVEL TO NEW CONCRETE BULB -OUT AND CONDUITS ARE INSTALLED BACKFILL WITH PEA-GRAVEL/ DIRT MIXTURE TO PROMOTE DRAINAGE. INSTALL DRAIN PIPE AT LOWER SLOPE FOR PROPER DRAINAGE. CONTRACTOR SHALL PROVIDE AND INSTALL A 120V PRI. TO 24VAC SEC. POWER SUPPLY WITH PRIMARY AND SECONDARY BREAKERS Q-TRAN PRODUCT NUMBER = QSET-120-120/24. AND FLUSH IN CONCRETE VAULT BOX #Q-VALT-5+SC+CR. DETAIL NOTES: GRAVEL BED 3/4" PVC 1 2 3 2 3 1 1" PVC 1" PVC 3/4" x 10'-0" COPPER CLAD DRIVEN GROUND ROD. PROVIDE 1#6 S.D.B.C. EXOTHERMIC WELDED OR UNDERGROUND RATED LUG CONNECT CONDUCTOR TO GROUND ROD. ROUTE GROUND WIRE TO GROUND LUG INCOMING POWER IN 3/4" PVC FROM EXISTING UTILITY SPLICE BOX. NEW 11" x 18" x 12" DP. TIER 22 POLYMER CONCRETE, FLUSH IN-GRADE SERVICE ENTRANCE BOX. (3) LUG, UNDERGROUND RATED TERMINAL BLOCK, ILSOC # PED3-3350SSP OR APPROVED EQUAL. INLINE NON-BREAKAWAY, SUBMERSIBLE FUSE HOLDER WITH 15A FUSE. BUSSMANN #HEB-JJ & BAF 15 FUSE OR APPROVED EQUAL. 5 6 4 4 5 6 COIL 5'-0" OF CONDUCTORS IN THIS BOX FOR FINAL CONNECTION BY F.C. L & P FORCES. EXISTING F.C. L & P UTILITY SPLICE BOX. IN TREE LAWN. (2#8 THWN CU) 3/4" PVC H N H G N G U S LOAD CALCULATION ECO BIKE TOTEM NEC DEMAND FACTOR 25 % 139/120 = 1.16 AMP @ 120V = 111 VA = 28 VA 139 VA ALL OF THIS EQUIPMENT IS IN THE CONCRETE BULB OUT. FLUSH IN-GRADE HAND HOLE/ SPLICE BOX. ZELT CABLE TO HAVE 8X TURNS IN ZELT LOOP DIAMOND. (TYP.) MINIMUM 30 TWIST PER YARD COPPER, STRANDED WIRE, ZELT CABLE. 16" 43" TO 60" SIZE TO FIT BIKE LANE POLYMER CONCRETE BOX. C 1/4" TO 1/2" WIDE X 2" DEEP SAW-CUT ZELT LOOP DIAMOND. THE DIAMOND SHAPE MUST BE PERFECT. EXISTING CURB OR NEW CONCRETE BULB-OUT CURB. EXISTING ROADWAY PAVEMENT BIKE LANE LINE CONDUIT ROUTED IN CONCRETE BULB-OUT OR BORE ACROSS REMINGTON TO ECO TOTEM. BLOCK-OUT IN CURB TO ALLOW ZELT CABLE INTO SAW-CUT IN ROADWAY PAVEMENT. SAW-CUT IN CONDUIT EXISTING CURB. 2" 1/4" TO 1/2" MICRO-CEMENT TO SEAL ROADWAY PAVEMENT FOAM 8X TURNS OF ZELT CABLE Sheet Date: Sheet Number: Drawing Name: Drawn by: Designed by: Revisions 1603 Oakridge Drive Fort Collins, CO 80525 (970) 223-7577 fax (970) 223-1827 Landscape Architecture Urban Design Graphic Design Checked by: NORTH 0 SCALE: Project Number: Project: Client: REMINGTON GREENWAY CITY OF FORT COLLINS ECO TOTEM ELECTRICAL PLAN 15075 10.30.2015 E02 1" = 10' 5' 10' 20' DR GF NC lighting design and engineering ECO TOTEM ELECTRICAL DETAIL ZELT INDUCTIVE LOOP DETAIL Sheet Number: Drawing Name: Drawn by: Designed by: Revisions 1603 Oakridge Drive Fort Collins, CO 80525 (970) 223-7577 fax (970) 223-1827 Landscape Architecture Urban Design Graphic Design Checked by: NORTH 0 SCALE: Project Number: Project: Client: REMINGTON GREENWAY CITY OF FORT COLLINS ECO TOTEM ELECTRICAL PLAN 15075 10.30.2015 E01 1" = 10' 5' 10' 20' DR GF NC ECO TOTEM ELECTRICAL PLAN lighting design and engineering FORT COLLINS LIGHT & POWER (F.C. L & P ) EXISTING UTILITY SPLICE BOX ADJACENT TO F.C. L & P'S ROADWAY LUMINAIRE. COIL 5'-0" OF CONDUCTORS. FINAL CONNECTION BY F.C. L & P FORCES. CONTRACTOR SHALL EXCAVATE A 15" W x30" L x30" D HOLE FOR THE POWER SUPPLY FLUSH IN-GRADE VAULT. AFTER BOX IS SET TO HEIGHT, LEVEL TO NEW CONCRETE BULB -OUT AND CONDUITS ARE INSTALLED BACKFILL WITH PEA-GRAVEL/ DIRT MIXTURE TO PROMOTE DRAINAGE. INSTALL DRAIN PIPE AT LOWER SLOPE FOR PROPER DRAINAGE. CONTRACTOR SHALL PROVIDE AND INSTALL A 120V PRI. TO 24VAC SEC. POWER SUPPLY WITH PRIMARY AND SECONDARY BREAKERS Q-TRAN PRODUCT NUMBER = QSET-120-120/24. AND FLUSH IN CONCRETE VAULT BOX #Q-VALT-5+SC+CR. NEW 11" x 18" x 12" DP. TIER 22 POLYMER CONCRETE, FLUSH IN-GRADE SERVICE ENTRANCE BOX. PLAN NOTES: 2 3 1 1 2 3 4 4