HomeMy WebLinkAboutRESPONSE - BID - 8327 TRANSFORMERS 150KVA THREE PHASE PAD-MOUNTEDFort Collins Utilities Transformer Bid Loss Data Sheet FCU Stock a T3000015 u Units 13 Bid M: ,,.,. Preparer Name : Leesa Kappler, Central Moloney Size 15DkVA Date: 31-May Preparer Contact Num: 870-543-6562 NL Loss Cast S 3.90 FL Loss Cost S 2.30 Includes Winding's Stray Losses 8 Losses Escalation Losses Associated associated Base Bid Base Bid $ / Guar No Load Guar Full Load Meet Specs? (Is / is not) Guar Total with Auxiliary Winding's with Auxiliary NL Loss' NL FL Loss' FL Evaluated Extended Cost Supplier Mtr / Mfrp Each Del/Wks Loss Loss Impedance (Yes / No) a factor Load Loss Devices (Yes / No) Stray Losses Devices Loss Cost Loss Cost Bid (Total $) Ventral Moloney Central Molone S 8,301.00 12 288 128E 215 yes is not 1574 YES 12:1 0 $ 1,123.20 $ 2,957.80 $ 12,382.00 $ 107,913.00 SUppliei 2 Mfr 2 $ - - 0 0 0.00 - - 0 - 0 0 $ - $ - $ - $ - Supplier 3 Mir 3 $ - - 0 0 0.00 - - 0 - 0 0 $ - $ - $ - $ - 1) No load losses 2) Full load losses — it shall be clearly stated whether this number includes the winding's expected stray losses and losses associated with auxiliary devices 3) Winding's expected stray losses related to quoted transformer design 4) Losses associated with auxiliary devices such as fuses, breakers, switches, etc. quoted loss values shall be corrected to a reference temperature of 85'C. Quotations submitted during the bid process without the required losses information shall be deemed unresponsive and are subject rejection by the City of Fort Collins. 1) Fill out the information in the cells with blue text. 2) Save the file using your company name and the bid number and e-mail it to: purchasing 0 fcgov.com (Example: TransformerSales_Bid_58.xls) To protect this tile, take the following steps: 1) Select Tools, Options 2) Select Security Tab 3) Type your password in the "Password to Open" field. 4) Re-enter your password to confirm it. Importantl Please remember to include this password in the bid information that will be sealed in the envelope that will be unsealed at Bid Opening. This will secure your data until the time of the bid opening. 5) Save the file and e-mail It to: purchasing@fcgov.com CG Power Systems USA Inc TECHNICAL SPECS _:•:.r., Date: 6,1134016 Customer Line No.: Quantity: 13 Unit Price: 4aS(o-7 _ Extended Price ?] f _ Three Phase Pad -Mount Transformer(s) kVA Rating: 150 kVA Model #: Mineral Oil Immersed Cooling Class: ONAN High -Altitude considcrations Frequency: 60 Hz @ 3300 Feet Avg. Winding Temp. 65 °C Primari %oltaec: 13200 Grdyn620 volts Secondary Voltage: 208Y!120 volts hrinwr-, MI. Rating,: 95 kV Secondary RIL Rating: 30 kV I1igh ti'oila a taps: B Taps -Two 2.5% •raps below Nominal and Two 2.5% Taps above Nominal No Load I n". Wnil's Load Loss: 1219 Watts Total Loss: 1572 Watts Unledanec: - — 115 Tank Enclost+re: — - Welded Cover w't 1) Handhole(s) - 1 Ox 16 Cabinet Depth. 19 Inches, Pentahead Security Bolts Steel HV-I.Y Barrier Bushings: Loop Feed Custom Dimensions Dmd Front Primary Terminations: Wells Secondar% Tonninations: Epo.• Bushings w/Ihread-on 4 Hole Aluminum H SL+adas, Spade Support ----�— ----- Protection:- — I ...;It Scminp Hayonet Fusing (353COS)_Plastic Dripshield O_PRC1.F %CBU(' 1504UC100) P •.. , ;::':1 .-1•e !at :nal 1=auit U,:tcvlor, Dn.iin plug LATIat N! 1 I.R PRESS AND P1iJ.rct1 PLUG (OR CAP) i 1" I ..--__'---- 110XU itc•t!oNable 1Juk — — -- Pauit Color: — — ---- ---- --- — DESERT TAN (MUNSELL I OYR6.0/3/0), Coal Tar Under Powder, Standards: -- '— uotad in coin lianee with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: 14 !o 19 :vccks —'--' -- Printed by YSGS-S.di> Kleekamp on 6l13i.036 Order/Quotation: 495913092-10 kVA: 150 Cabinet Height (mm): 1562 (61") HV: 13200Y17620 Weight (lbs): 3334 EV. 20EY1120 Coolant (gallons): 140 TRANSFORMER OVERHEAD VIEW 33 (1.5) lip �c Ww ----------------------- ------- -- SO (2") lip �— (40, S" 1667 (65.6"} Dimensions are preliminary and not for construction. 0 CG Power Systems USA! Inc. Washington, Missouri (USA) _ Routine Tests Detailed ANSIIIEE-E C57.12.90 Remarks Acceptance Description of Tests Section Criteria Winding Resistance measurements Section 5 Of all windings on the ratoo voltage lap and at the tap extremes Total Loss within tolerance Ratio test and phase relation SeCtiD1, 6. 7 On the rated voltage connection, and on all lap connections _0.51'< of Calculated Ratio No-load and excitation current Sec; on 8 At 100Y, and 110% voltage and at rated frequency - ; 09•; of Guaranteed NLL At rated current and frequency on the rated voltage connection and at Impedance voltage and load loss Secrar 9 the tap extremes -6`4 or Guaranteed Total Losses c1.5 of Guaranteed %IZ Low Frequency Tests Sectior 10.6 On rated voltage connection o' o� mary and secondary windings. — Applied voltage RV Winding Test Voltage: See IEEE C57.12.90 LV Winding Test Voltage: — Induced voltage Section 10.7 On the rated voltage connection of primary & secondary windings. Sec IEEE C57,12.90 (Class I Power Transformer Test) AC Level: 2 times rated vellage for 7200 cycles. Quality Control test. One redured wave followed by ore full wave on Lightning Impulse Test Section 10.4 NV phase terminals only. Chopped wave and switching impulse See IEEE C57.12.90 are not included. Auxiliary Wiring Dielectric Test Dielectric meg ar of ID00VDC;o ground See IEEE C57.12.90 Bushing Current Transformers Dielectric meggar of 2500VDC to ground -0.5 0 of Calculated Ratio Check of polarity and ratio of ocseiing current transformers. Standard Leak test of Fully Assembled Transformer Section 8.2 of C57.12.00 5 psig of dry air (oil at ambier,::emperature) for 24 hours No Leaks Mechanical Inspection Conformance to specs, standards ano drawings. See Remarks Check of layout, dimensions. clearances. etc. Check of nameplate data. Functional test of all accessories and auxiliary devices Page 1 of 1 CG Power Systems USA Inc Rf;aveled la! a $ P;•nll Cna'aa oet; Ddv, t'lashm im. Ul ssoun 631380. USA TEST PRICE SCHEDULE — 2500 kVA and Smaller Following list prices shall be respected for test in accordance to the latest ANSI standards at time of quotation: Sman solutions. SVona relallonsn'ps. Description Unit Size Unit price each Remarks Full impulse test 2500 kVA and smaller $900 Heat Run Test, OA kVA and smaller 52400 rating or one rating 11000 I jl only' Heat Rur. Test, OA 1500 kVA uo to and $2700 i rating or one rating including 2500 kVA only* Heat Run test, each 2500 kVA and smaller $1050 add. FA rating* Sound level test, one 2500 kVA and smaller $600 rating only Sound level test, each 2500 kVA and smaller $400 additional ratio Insulation PIF test (not Z500 kVA and smaller $200 do_ble test) Oil Quality test 1 2500 kVA and smaller S200 Outside Lab Per sam le 0o DGA test 2500 kVA and Smaller — t _ S400 : Outside Lab Per sample i Short Circuit test 2500 kVA and smaller TO BE REQUESTED Outside Lab Witness testing* 2500 kVA and smaller $750 per day To be scheduled in advance * Witness Testing or Temperature Rise Testing will add 1-2 weeks to shipment schedule. The controlled copy of this dnetnnent is located on the PSUS Intranet Site. This copy sans pnntM on i 26 19 at In21 AM AVANT IIA CROUP COMPANY W Power Systems USA Inc One Pauwels Drive, Washington, Missouri 63090, USA T: + 1 636 239 9300 F: + 1 636 239 9398 W: wwwxgglobal.cont CANCELLATION SCHEDULE STATUS SA1,ES PRICr: _ Order Acknowledged 5% Scheduled • Order Scheduled 10% Engineering • Drawings Issued 15% Production Control • Final Material Ordered 30% • Schedules Issued To Plant 35% Transformer Production _•_ T. Started • Core Starlcd '---- • Coil Sla reed • Adtanccd Asscinhlcd farts (Core & Coils) -- - _ SD"k - 65rYr 7551, 10044 — 0 Oven - 1001k • Tanked 100% • Tested 100% • Final Assembly 100% • Dock 100% Shipped 100% Sally Kleekamp Account Specialist Brian McCarrick Product Sales Manager The controlled copy of this document is located on the SharePoint Intranet Site. This copy was printed on 10/142015 at 10:06 AM PSUS-Sally Kleekamp. Smart solutions. Slrong relationships. AVANTI-IA GROUP COMPANY CG Power Systems USA Inc One Pauwcls Drive, Washington, Missouri 63090, IJSA T: - 1 636 239 9300 F: - 1 636 239 9395 IN:.mw.cseiobaLeom Sinari solutions. SOGng rulationstdps. WARRANTY TERMS WARRANTY: Company warrants to Purchaser that the equipment to be delivered to Purchaser will be free from defects in material and workmanship when used under proper and normal use for a period of 12 months after the equipment is put into service. Not to exceed 18 months from the date the equipment is delivered (whether by sale, lease or rental). Organic insulation materials are sold with the express understanding that their life and fitness for purpose are indeterminate and largely depend on application and operating circumstances and continuing maintenance. Should any failure to conform to the above (or to any additional warranty contained in the special conditions of sale set forth in the applicable product -line price sheet) appear with within one (1) year after the date of shipment by Company, the Company agrees, upon prompt notification thereof and conformation that the equipment has been stored, installed, operated and maintained in accordance with recommendations of the Company and standard industry practice, to correct the nonconformity at Company's option either by repairing any defective part or parts or by making available at Company's plant a repaired or replacement part. The liability of Company to Purchaser arising out of the supplying of said equipment or its use, whether on warranty, contract or negligence, shall not in any event exceed the cost of correcting defects in the equipment as herein provided, and upon the expiration of said one (1) year, all such liability shall terminate. The foregoing shall constitute the sole remedy of the Purchaser and the sole liability of Company. The Warranty does not and shall not include reimbursement for the expenses which may be incurred by Purchaser. Before any material is returned, Purchaser must contact Company, as outlined under Returned Goods. No warranty is made with respect to equipment not manufactured by Company, such being subject only to warranties made by their respective manufacturers. Company shall in no event be responsible or liable for modifications, alterations, misapplication or repairs made to its products or equipment by Purchaser or others, or for damage caused thereto by negligence, accident, overloading or improper use by Purchaser or others. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN, ORAL OR IMPLIED (INCLUDING ANY WARRANTY ON MERCHANTABILITY OR FITNESS FOR PURPOSE). THE ONLY WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE ARE THOSE EXPRESSED ABOVE AND THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR PURPOSE. One Pauwels Drive, Washington MO 63090 PH 636-239-9300, FAX 636-239-9398 The controlled copy of this document is located on the. PSUS Intranet Site. This copy was printed on 1/15/2015 at 9:31 AM. CG Power Systems USA Inc Registered Office & Plant: One Pau%vels Drive Washington MO 63090 cop small solullans. strong iclallanshlps. SUBJECT: Certification or compliance with rederal laws governing PCB content of oil and oil -filled transformers. REFERENCE: Final rule on PCB's per Environmental Protection Agency Part IV Federal Register Vol. 44, Nos. 106, dated May 31, 1979 As part of our program for compliance with Federal Environmental Laws, we are required to maintain and certify that our product and production oil system contains less than 50 PPM of PCB's (Polychlorinated Biphenyls.) This letter is to certify that CG Power Systems USA Inc supplies insulating oll-filled equipment with oil which contains less than 1 PPM PCBs. Our suppliers of oil have certified to us that no PCB's are introduced into the oil any time during their processing. We have no knowledge that CG Power Systems USA Inc has produced a product containing over 50 PPM of PCBs. Our certification is maintained by ensuring that all new oil received at our plant is PCB free, by periodic testing of samples from various plant locations and requiring that returned product containing oil be certified to less than 1 PPM PCB. The serial numbers for certified transformers will be 89A-- or later. The first two numbers are the year and the letter is the month of order entry. We do not anticipate transmitting test results in the form of reports or guarantees for specific individual units. __A/ 14-�- Jeff Barnes Total Quality Manager Fort Collins Utilities Transformer Bid Loss Data Sheet FCU Stock # 13000015 # Units Bid #: Preparer Name : Name sally Size 15DkVA Date: Date I,f,. Preparer Contact Num: Number 495913092 NL Loss Cost s 3.90 FL Loss Cost 230 Includes Winding's Stray Losses & Losses Escalation Losses Associated associated Base Bid Base Bid $ / Guar No Load Guar Full Load Meet Space? (Is / is not) Guar Total with Auxiliary Winding's with Auxiliary NL Loss' NL FL Loss' FL Evaluated Extended Cost Supplier MIT / Mr# Each DeVWks Loss Loss impedance (Yes / No) a factor Load Loss Devices (Yes / No) Stray Losses Devices Loss Cost Loss Cost Bid (Total $) Supplier 1 Power S 6,567.00 16-18 weeks 353 121n 2.1 S yes is not 1572 - r, (I $ 1,376.70 $ 2,803.70 $ 10,747.40 $ 85,371.00 Supplier 2 Mir 2 S - - 0 0 0-00 - 0 0 0 $ - IS - IS - $ - Supplier 3 MIT 3 S - - 0 0 0.00 - - 0 - 0 0 $ $ - $ - IS - 2) Full load losses — it shall be clearly stated whether this number includes the winding's expected stray losses and losses associated with auxiliary devices 3) Winding's expected stray losses related to quoted transformer design 4) Losses associated with auxiliary devices such as fuses, breakers, switches, etc. quoted loss values shall be corrected to a reference temperature of 85°C. Quotations submitted during the bid process without the required losses information shall be deemed unresponsive and are subject rejection by the City of Fort Collins. Fill out the information in the cells with blue text. Save the file using your company name and the bid number and e-mail it to: purchasing@fcgov.com (Example: TransfornerSales_Bid-58.xis) Select Tools, Options Select Security Tab Type your password in the "Password to Open' field. Re-enter your password to confirm it. Important! Please remember to include this password in the bid information that will be sealed in the envelope that will be unsealed at Bid Opening. This will secure your data until the time of the bid opening. Save the file and e-mail it to: purchasing@fcgov.com Fort Collins Utilities Transformer Bid Loss Data Sheet FCU Stock # T3000015 # Units 13 Bid #: Preparer Name : LaKetia Davis Size 1500A Date: Preparer Contact Num: 3301-425-3151 NL Loss Cost $ 3.90 FL Loss Cost $ 2.30 Includes Winding's Stray Losses a Losses Escalation Losses Associated associated Base Bid Base Bid $ / Guar No Load Guar Full Load Meet Specs? (Is / Is not) Guar Total with Auxiliary Winding's with Auxlllary NL Loss' NL FL Loss • FL Evaluated Extended Cost Supplier Mfr / Mfr# Each Del/Wks Loss Loss Impedance (Yes / No) a factor Load Lose Devices (Yes / No) Stray Losses Devices Loss Cost Loss Cost Bid (Total $) Howard Industrie Howard Indust, $ 6,116.00 f3-8 Wks ARO 333 1290 2.00 Yes,, NO 1623 Yes 25 0 $ $ 2,967.00 $ 10,262.70 $ 79,508.00 Supplier 2 Mfr 2 $ - - 0 0 0.00 - - 0 - 0 0 $ - $ $ $ - Supplier 3 Mfr 3 $ - - 0 0 000 - - 0 - 0 0 $ - $ - $ - $ Full load losses — it shall be clearly stated whether this number includes the winding's expected stray losses and losses associated with auxiliary devices Winding's expected stray losses related to quoted transformer design Losses associated with auxiliary devices such as fuses, breakers, switches, etc. All quoted loss values shall be corrected to a reference temperature of 85"C. Quotations submitted during the bid process without the required losses information shall be deemed unresponsive and are subject to rejection by the City of Fort Collins. Fill out the information in the cells with blue text. Save the file using your company name and the bid number and e-mail it to: purchasing@fcgov.com (Example: TransformerSales_Bid_58.xls) To protect this file, take the following steps: 1) Select Tools, Options 2) Select Security Tab 3) Type your password in the "Password to Open" field. 4) Re-enter your password to confirm it. Important! Please remember to include this password in the bid information that will be sealed in the envelope that will be unsealed at Bid Opening. This will secure your data until the time of the bid opening. 5) Save the file and e-mail it to: purchasing@fcgov.com EXHIBIT A BID ACKNOWLEDGEMENT Contractor hereby acknowledges receipt of the City of Fort Collins Utilities' Request for Bids for the Transformers and acknowledges that it has read and agrees to be fully bound by all of the terms, conditions and other provisions set forth in the Bid. Additionally, the Contractor hereby makes the following representations to Utilities: a. All of the statements and representations made in this bid are true to the best of the Contractor's knowledge and belief. b. The Contractor has obtained all necessary authorizations and approvals that will enable the Contractor to commit to the terms provided in this bid submittal. c. This bid submittal is a firm and binding offer, for a period of 45 days from the date hereof. d. I further agree that the method of award is acceptable to my company. e. 1 acknowledge receipt of _ addenda. Contractor Firm Name: n��c�e s `�n_%Ve A F 1 o C�- c Cl op4� Physical Address: ,Do 93rpmAa_Q Lnc t \ i cb gu(0� Remit to Address: Phone: —7 070- S S-0 - -7 D Q 1 Authorized Agent of Firm Name: Signature of Authorized Agent: Primary Contact for Project: Title: c%o ,Sa i. o S Email Address: SL na\V N COOP Phone: 7c)O - 990- —7041 Cell Phone: 8327 Transformers 150 kVA 3-Phase Page 4 of 31 8327 TRANSFORMERS, 150KVA BID SCHEDULE WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR 8327 TRANSFORMERS, 150KVA, THREE PHASE, PAD -MOUNTED PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS, QUANTITY: DESCRIPTION: 13 ea. T3000015 TRANSFORMER, 150 kVA PAD -MOUNTED COMPARTMENTAL TYPE, THREE PHASE DISTRIBUTION WITH SEPARABLE INSULATED LOAD BREAK HIGH VOLTAGE CONNECTORS. HIGH VOLTAGE RATING: 13200 GRDY/7620. LOW VOLTAGE RATING: 208Y/120. SERIAL NUMBER 015 TO BE IN ACCORDANCE WITH SPECIFICATION #368-300-015, REVISION PP. Please complete the Excel spreadsheet issued separately for bid submittal. The spreadsheet MUST be submitted in Excel format only. Failure to submit in the format requested may cause the submittal to be deemed incomplete and may be subject to rejection. IF YOU ELECT TO PASSWORD PROTECT YOUR BID, PLEASE NOTE THAT PASSWORD IN A SEPARATE EMAIL TO ourchasing(a)fcgov.com at the time of bid submittal. "Any surcharges or additional costs shall be noted & included in bid submittal. Delivery lead time may be a consideration of bid award. For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid. Awards from this bid will be based primarily on the evaluated bid price. Delivery lead times, escalation and exceptions taken will also be considered. The City of Fort Collins reserves the right to split the bid award in whatever percentages are most advantageous to the City. Future orders of 150KVA THREE PHASE, PAD -MOUNTED may be authorized, at the option of the City, from this bid for a period of five years after bid closing date. Satisfactory pricing, losses and delivery are required for future orders based on this bid. 8327 Transformers 150 kVA 3-Phase Page 3 of 31 Howes Inc. �I1:� 1.AJEiRllIREIIYLJU4 M.7: }• 'nd(osmerDivision Ro 3oa1b88 • lawei h7S 39441-1588 Phcne. 601 425 3151 Fax 6C1 649 8090 SILICON FOB: DESTINATION VALIDITY: 30 DAYS WESTERN UNITED ELEC SPY PRICING:FIRM FOR QUOTED SHIPMENT TERMS: NET 30 DAYS 100 BROMLEY BUSINESS PKW AGENT: POWER EQUIPMENT SPECIALS INQUIRY: CITY OF FORT BRIGHTON, CO 80603 COLLINS Item ITEM 1 13 PRODUCT: 3-PHASE PADMOUNt ANSI C57.12.34 DEAD FRONT SINGLE VOLTAGE KVA: 150 KVA HV: 13200GRDY/7620 + GRD 95KV BIL IV: 208Y/120 30KV BIL TAPS: (2) 2-1,''2 ABOVE & BELOW LOSSES: NO LOAD = 333, LOAD = 1290, TOTAL = 1623 IMPED = 2.0 OIL TYPE: MINERAL QUOTED PER CUSTOMER SPEC DATED 5/9/14 EVALUATED: NO LOAD = 3.90 LOAD = 2.30 THREE PHASE PADMOUNT, DEAD FRONT, LOOP FEED. 2016 DOE COMPLIANT **NOTE: GUARANTEED LOSSES QUOTED **NOTE: TAKING EXCEPTION TO 4 WAY PALLET, QUOTING RUNNERS FOR 2 WAY ENTRY. ORDERS REQUIRING APPROVAL DRAWINGS: LEADTIMES QUOTED ASSUME THAT APPROVAL DRAWINGS WILL BE SIGNED AND RETURNED TO HOWARD INDUSTRIES WITHIN TWO WEEKS OF RECEIPT OF SAID DRAWING. SHOULD THE PROCESS REQUIRE ANY ADDITIONAL TIME BEYOND THESE TWO WEEKS, THAT ADDITIONAL TIME WILL BE ADDED TO THE QUOTED LEADTIME. TRANSFORMERS ON THIS QUOTATION ARE DESIGNED TO COMPLY WITH DOE EFFICIENCY REQUIREMENTS EFFECTIVE FOR COWERED TRANSFORMERS COMPLETING MANUFACTURE BEGINNING JANUARY 1, 2016. UNCONTROLLED COPY LAST PAGH UNLE55 VIEWED ON A PC FROM THE =Sham on Howardpdo Drlvo QUOTATION QUOTAI'10` DATE:06/06/2016 PAGE NO: 1 Shipment Unit Price ARO `116 06-08 WKS SUBMITTED BY LAKETIA HILL Neuesaa.eal } DESCRIPTION DWG No. HOWARD NOT FOR CONSTRUCTION LAUREL,®WDIISTRINC. 440 THREE PHASE PAD DISTRIBUTION TRANSFORMERS CUSTOMER : FORT COLLINS. CO. 6& SPEC. — DATED o 0 KVA 150, 0 BIL 95 TAPS — % HIGH VOLTAGE13200GRDY/7620 ' LOW VOLTAGE I— 1 ri APPROX. CORE AND COIL WEIGHT 1341 i I I I APPROX. TANK AND ACCESS. WEIGHT 1 I----------� GAL. OF OIL 31 APPROX, WEIGHT 1373 APPROX. TOTAL WEIGHT 4 o 0 0 2, REV. DATE DESCRIPTION p ai A NOTE. THE WEIGHTS AND DIMENSIONS ARE APPROXIMATE AND SUBJECT TO CHANGE WITHIN THE CUSTOMER SPECIFIED LIMITS. APPROVAL DRAWINGS WITH THE ACTUAL WEIGHTS AND DIMENSIONS WILL BE 2S PROVIDED UPON REQUEST AFTER RECEIPT OF ORDER. 41 5 7 NOTE: (1) DIMENSIONS IN INCHES 3g (2) WEIGHTS IN POUNDS 12 Tl 10 50 8 2 22 o L 4. m "'A "is O 1Sd 1Y1 o vA "®° xwro x2 cu 21 3 sIr N 212 o IL 4. 4 14 51 15 t4 13 1. 4, 47.65 _ r 00 N W 1 LV BUSHING & 4—HOLE SPADE 2 LV SPADE SUPPORT 3 1 2-13 GROUND PAD 4 HV BUSH DF WELL 5 LOADBREAK PARKING STAND 7 NP ON DOOR, SERIAL ON TANK 8 TANK 10 HANDHOLE &SECURITY COVER 12 LIFTING LUGS 13 JACKING PROVISIONS 14 1/2-13 GROUND PAD 15 1 IN PIPE PLUG — VERA SEAL 21 PADLOCKABLE DOOR HANDLE 22 3 PT LATCH PENTA SEC BOLT 24 12 IN REMOVABLE SILL 25 METAL LV—HV BARRIER 39 CUP ON DRIP SHIELD 41 BAYONET FUSE HOLDER 47 IFD NON—RESETTABLE DEVICE 48 DIAL THERM W MAX POINTER 50 OIL LEVEL PLUG 51 TAP CHANGER HANDLE 52 10 UPPER FILTER PRESS CONN SPECIAL NOTES A BAY—O—NET FUSE B CURRENT LIMITING FUSE n E T NO DWG BY HL DATE, 05 31 is PP BYd CC. 745 0.050 91506311S,6M, 16, O,FO8 ,169, 34, 45 524773, 626571.2, 321.2. 1263 59000000.210 No. HL8323001 THREE PHASE r1 O YY ARD M]I DVS RIES USAREL MS 39440 TRANSFORMER i7 YY 1111 11V DOE COMPLIANT lJ 1 i� l 1 READ INSTRUCTION HI 105 BEFORE OPERATING MFG KVA 150 BIL HV 95 LV 3OKV 2.0%mp HV 132000RDY/7620 Lv208Y/120 AMPS 416 LB TANK 831 C&C 1341 T9, II 18,3 GAL TOTAL 3545 LBS CONT 65 'C RISE CLASS ONAN 60HZ TANK DESIGNED FOR +7 PSIG F1 CLF PARTIAL RANGE — F2 BAYONET FUSE \ i o CONTAINS NO DETECTABLE LEVEL OF PCB (LESS \ THAN 2 PPM) AT THE TIME OF MANUFACTURE. \O J F V13LTAGE P13S AMPS o FL 13860 1/A 6.25 eHV LV AL 13530 2/B 6.40 H x 13200 3/c 6.56 AL 'A H ; I x2x3 Ho xo 12870 4/D 6.73 12 1 H1 H xt x 0 SER. NO. BAR CODE CAT. N0. BAR CODE SER. NLT, HOWARD M) INDUSTRIES INC. LAUREL, MISS. USA 39440 MFG. OF DISTRIBUTION TRANSFORMERS NAME: LASER NAME PLATE cc 857 DESCR: LF/TP/2FUSE Y—Y ID 3CHLO136 DWG: HL8323001 E VI S I O N I BY APP SCALE 1.000 1 DWG BY CHK BY DATE1 /16 CENTRAL MOLONEY, INC. PAGE: 1 TO: DAVE BAUER @ PETERSON SUBJECT: CITY OF FORT COLLINS CUSTOMER NAME:CITY OF FORT COLLINS CUST:CITY WE ARE PLEASED TO GIVE YOU THE FOLLOWING QUOTATION: DATE: 05/31/16 FROM: LEESA KAPPLER INQUIRY NO:8327 5-31-16 QUOTATION NO:69100 ITEM I QTY I KVA I TYPE ! PRIMARY I SECONDARY iCORE I COPPER ISHIP WEEKS UNIT -PRICE EFF BUSH I TAPS ITEM I QTY I KVA I TYPE I PRIMARY I SECONDARY ICORF. I COPPER ISHIP WEEKSI UNIT -PRICE COMMENTS: QUOTE VALID FOR 30 DAYS. DOE 2016 COMPLIANT TAPS PRICE INCLUDES THE IFD. STOCK -CODE %I Z PRICES ARE FIRM FOR DELIVERY QUOTED UNLESS OTHERWISE STATED. THIS QUOTATION IS VALID FOR ACCEPTANCE WITHIN THIRTY(30) DAYS FROM DATE HEREOF AND, IN THE MEANTIME, IS SUBJECT TO CHANGE UPON NOTICE. STANDARD TERMS AND CONDITIONS OF SALE FORM 300322, WILL APPLY. PLEASE NOTE THAT TERMS ARE NET THIRTY(30) DAYS AFTER DATE ON INVOICE. FAX:(870)543.6560 PHONE:(870)534-5332 P.O. BOX 6608 PINE BLUFF, AR 71611