HomeMy WebLinkAboutRESPONSE - BID - 8327 TRANSFORMERS 150KVA THREE PHASE PAD-MOUNTEDFort Collins Utilities Transformer Bid Loss Data Sheet
FCU Stock a
T3000015
u Units
13
Bid M: ,,.,.
Preparer Name :
Leesa Kappler, Central Moloney
Size
15DkVA
Date: 31-May
Preparer Contact Num:
870-543-6562
NL Loss Cast
S 3.90
FL Loss Cost
S 2.30
Includes Winding's
Stray Losses 8
Losses
Escalation Losses Associated
associated
Base Bid
Base Bid $ /
Guar No Load
Guar Full Load Meet Specs?
(Is / is not) Guar Total with Auxiliary
Winding's with Auxiliary NL Loss' NL
FL Loss' FL
Evaluated
Extended Cost
Supplier
Mtr / Mfrp
Each
Del/Wks Loss
Loss Impedance (Yes / No)
a factor Load Loss Devices (Yes / No)
Stray Losses Devices Loss Cost
Loss Cost
Bid
(Total $)
Ventral Moloney
Central Molone S 8,301.00
12 288
128E 215 yes
is not 1574 YES
12:1 0 $ 1,123.20
$ 2,957.80
$ 12,382.00
$ 107,913.00
SUppliei 2
Mfr 2
$ -
- 0
0 0.00 -
- 0 -
0 0 $ -
$ -
$ -
$ -
Supplier 3
Mir 3
$ -
- 0
0 0.00 -
- 0 -
0 0 $ -
$ -
$ -
$ -
1) No load losses
2) Full load losses — it shall be clearly stated whether this number includes the winding's expected stray losses and losses associated with auxiliary devices
3) Winding's expected stray losses related to quoted transformer design
4) Losses associated with auxiliary devices such as fuses, breakers, switches, etc.
quoted loss values shall be corrected to a reference temperature of 85'C. Quotations submitted during the bid process without the required losses information shall be deemed unresponsive and are subject
rejection by the City of Fort Collins.
1) Fill out the information in the cells with blue text.
2) Save the file using your company name and the bid number and e-mail it to: purchasing 0 fcgov.com
(Example: TransformerSales_Bid_58.xls)
To protect this tile, take the following steps:
1) Select Tools, Options
2) Select Security Tab
3) Type your password in the "Password to Open" field.
4) Re-enter your password to confirm it.
Importantl Please remember to include this password in the bid information that will be sealed in the envelope that will be
unsealed at Bid Opening. This will secure your data until the time of the bid opening.
5) Save the file and e-mail It to: purchasing@fcgov.com
CG Power Systems USA Inc
TECHNICAL SPECS
_:•:.r.,
Date:
6,1134016
Customer Line No.:
Quantity:
13
Unit Price: 4aS(o-7 _
Extended Price
?] f
_
Three Phase Pad -Mount Transformer(s)
kVA Rating: 150 kVA
Model #:
Mineral Oil Immersed
Cooling Class:
ONAN
High -Altitude considcrations
Frequency:
60 Hz
@ 3300 Feet
Avg. Winding Temp.
65 °C
Primari %oltaec: 13200 Grdyn620 volts
Secondary Voltage:
208Y!120 volts
hrinwr-, MI. Rating,: 95 kV
Secondary RIL Rating:
30 kV
I1igh ti'oila a taps: B Taps -Two 2.5% •raps below Nominal
and Two 2.5% Taps above Nominal
No Load I n". Wnil's Load Loss:
1219 Watts
Total Loss: 1572 Watts
Unledanec: - — 115
Tank Enclost+re:
— -
Welded Cover w't 1) Handhole(s) - 1 Ox 16
Cabinet Depth. 19 Inches, Pentahead Security Bolts
Steel HV-I.Y Barrier
Bushings:
Loop Feed Custom Dimensions
Dmd Front Primary Terminations: Wells
Secondar% Tonninations: Epo.• Bushings w/Ihread-on 4 Hole Aluminum H SL+adas, Spade Support
----�— -----
Protection:-
—
I ...;It Scminp Hayonet Fusing (353COS)_Plastic Dripshield O_PRC1.F
%CBU(' 1504UC100)
P •.. , ;::':1 .-1•e !at :nal 1=auit U,:tcvlor, Dn.iin plug
LATIat N! 1 I.R PRESS AND P1iJ.rct1 PLUG (OR CAP) i 1" I
..--__'----
110XU itc•t!oNable 1Juk
— — --
Pauit Color:
— — ----
---- --- —
DESERT TAN (MUNSELL I OYR6.0/3/0), Coal Tar Under Powder,
Standards:
-- '—
uotad in coin lianee with the latest applicable ANSI standards unless otherwise specified by the
customer.
Shipment: 14 !o 19 :vccks
—'--' --
Printed by YSGS-S.di> Kleekamp on 6l13i.036
Order/Quotation: 495913092-10
kVA: 150 Cabinet Height (mm): 1562 (61")
HV: 13200Y17620 Weight (lbs): 3334
EV. 20EY1120 Coolant (gallons): 140
TRANSFORMER OVERHEAD VIEW
33 (1.5) lip
�c
Ww
----------------------- ------- --
SO (2") lip
�— (40, S" 1667
(65.6"}
Dimensions are preliminary and not for construction.
0
CG Power Systems USA! Inc.
Washington, Missouri (USA)
_ Routine Tests
Detailed
ANSIIIEE-E C57.12.90
Remarks
Acceptance
Description of Tests
Section
Criteria
Winding Resistance measurements
Section 5
Of all windings on the ratoo voltage lap and at the tap extremes
Total Loss within tolerance
Ratio test and phase relation
SeCtiD1, 6. 7
On the rated voltage connection, and on all lap connections
_0.51'< of Calculated Ratio
No-load and excitation current
Sec; on 8
At 100Y, and 110% voltage and at rated frequency
- ; 09•; of Guaranteed NLL
At rated current and frequency on the rated voltage connection and at
Impedance voltage and load loss
Secrar 9
the tap extremes
-6`4 or Guaranteed Total Losses
c1.5 of Guaranteed %IZ
Low Frequency Tests
Sectior 10.6
On rated voltage connection o' o� mary and secondary windings.
— Applied voltage
RV Winding Test Voltage:
See IEEE C57.12.90
LV Winding Test Voltage:
— Induced voltage
Section 10.7
On the rated voltage connection of primary & secondary windings.
Sec IEEE C57,12.90
(Class I Power Transformer Test)
AC Level: 2 times rated vellage for 7200 cycles.
Quality Control test. One redured wave followed by ore full wave on
Lightning Impulse Test
Section 10.4
NV phase terminals only. Chopped wave and switching impulse
See IEEE C57.12.90
are not included.
Auxiliary Wiring Dielectric Test
Dielectric meg ar of ID00VDC;o ground
See IEEE C57.12.90
Bushing Current Transformers
Dielectric meggar of 2500VDC to ground
-0.5 0 of Calculated Ratio
Check of polarity and ratio of ocseiing current transformers.
Standard Leak test of Fully Assembled
Transformer
Section 8.2 of C57.12.00
5 psig of dry air (oil at ambier,::emperature) for 24 hours
No Leaks
Mechanical Inspection
Conformance to specs, standards ano drawings.
See Remarks
Check of layout, dimensions. clearances. etc.
Check of nameplate data.
Functional test of all accessories and auxiliary devices
Page 1 of 1
CG Power Systems USA Inc
Rf;aveled la! a $ P;•nll
Cna'aa oet; Ddv, t'lashm im. Ul ssoun 631380. USA
TEST PRICE SCHEDULE — 2500 kVA and Smaller
Following list prices shall be respected for test in accordance to the latest ANSI
standards at time of quotation:
Sman solutions.
SVona relallonsn'ps.
Description
Unit Size
Unit price each
Remarks
Full impulse test
2500 kVA and smaller
$900
Heat Run Test, OA
kVA and smaller
52400
rating or one rating
11000
I
jl
only'
Heat Rur. Test, OA
1500 kVA uo to and
$2700
i rating or one rating
including 2500 kVA
only*
Heat Run test, each
2500 kVA and smaller
$1050
add. FA rating*
Sound level test, one
2500 kVA and smaller
$600
rating only
Sound level test, each
2500 kVA and smaller
$400
additional ratio
Insulation PIF test (not
Z500 kVA and smaller
$200
do_ble test)
Oil Quality test
1 2500 kVA and smaller
S200 Outside Lab
Per sam le
0o DGA test
2500 kVA and Smaller — t
_
S400 : Outside Lab
Per sample
i Short Circuit test
2500 kVA and smaller
TO BE REQUESTED
Outside Lab
Witness testing*
2500 kVA and smaller
$750 per day
To be scheduled in
advance
* Witness Testing or Temperature Rise Testing will add 1-2 weeks to shipment
schedule.
The controlled copy of this dnetnnent is located on the PSUS Intranet Site.
This copy sans pnntM on i 26 19 at In21 AM
AVANT IIA
CROUP COMPANY
W Power Systems USA Inc
One Pauwels Drive, Washington, Missouri 63090, USA
T: + 1 636 239 9300 F: + 1 636 239 9398 W: wwwxgglobal.cont
CANCELLATION SCHEDULE
STATUS
SA1,ES PRICr:
_
Order Acknowledged
5%
Scheduled
• Order Scheduled
10%
Engineering
• Drawings Issued
15%
Production Control
• Final Material Ordered
30%
• Schedules Issued To Plant
35%
Transformer Production
_•_ T. Started
• Core Starlcd '----
• Coil Sla reed
• Adtanccd Asscinhlcd farts
(Core & Coils)
-- -
_
SD"k
- 65rYr
7551,
10044
—
0 Oven
- 1001k
• Tanked
100%
• Tested
100%
• Final Assembly
100%
• Dock
100%
Shipped
100%
Sally Kleekamp
Account Specialist
Brian McCarrick
Product Sales Manager
The controlled copy of this document is located on the SharePoint Intranet Site.
This copy was printed on 10/142015 at 10:06 AM PSUS-Sally Kleekamp.
Smart solutions.
Slrong relationships.
AVANTI-IA
GROUP COMPANY
CG Power Systems USA Inc
One Pauwcls Drive, Washington, Missouri 63090, IJSA
T: - 1 636 239 9300 F: - 1 636 239 9395 IN:.mw.cseiobaLeom
Sinari solutions.
SOGng rulationstdps.
WARRANTY TERMS
WARRANTY: Company warrants to Purchaser
that the equipment to be delivered to Purchaser
will be free from defects in material and
workmanship when used under proper and normal
use for a period of 12 months after the equipment
is put into service. Not to exceed 18 months from
the date the equipment is delivered (whether by
sale, lease or rental). Organic insulation materials
are sold with the express understanding that
their life and fitness for purpose are indeterminate
and largely depend on application and operating
circumstances and continuing maintenance.
Should any failure to conform to the above (or to
any additional warranty contained in the special
conditions of sale set forth in the applicable
product -line price sheet) appear with within one (1)
year after the date of shipment by Company, the
Company agrees, upon prompt notification thereof
and conformation that the equipment has been
stored, installed, operated and maintained in
accordance with recommendations of the
Company and standard industry practice, to
correct the nonconformity at Company's option
either by repairing any defective part or parts or by
making available at Company's plant a repaired or
replacement part. The liability of Company to
Purchaser arising out of the supplying of said
equipment or its use, whether on warranty,
contract or negligence, shall not in any event
exceed the cost of correcting defects in the
equipment as herein provided, and upon the
expiration of said one (1) year, all such liability
shall terminate. The foregoing shall constitute
the sole remedy of the Purchaser and the sole
liability of Company. The Warranty does not and
shall not include reimbursement for the expenses
which may be incurred by Purchaser. Before any
material is returned, Purchaser must contact
Company, as outlined under Returned Goods. No
warranty is made with respect to equipment not
manufactured by Company, such being subject
only to warranties made by their respective
manufacturers. Company shall in no event be
responsible or liable for modifications, alterations,
misapplication or repairs made to its products or
equipment by Purchaser or others, or for damage
caused thereto by negligence, accident,
overloading or improper use by Purchaser or
others.
THE FOREGOING WARRANTY IS EXCLUSIVE
AND IN LIEU OF ALL OTHER WARRANTIES
WHETHER WRITTEN, ORAL OR IMPLIED
(INCLUDING ANY WARRANTY ON
MERCHANTABILITY OR FITNESS FOR
PURPOSE). THE ONLY WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR
PURPOSE ARE THOSE EXPRESSED ABOVE
AND THERE ARE NO IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR
PURPOSE.
One Pauwels Drive, Washington MO 63090 PH 636-239-9300, FAX 636-239-9398
The controlled copy of this document is located on the. PSUS Intranet Site.
This copy was printed on 1/15/2015 at 9:31 AM.
CG Power Systems USA Inc
Registered Office & Plant:
One Pau%vels Drive
Washington MO 63090 cop
small solullans.
strong iclallanshlps.
SUBJECT: Certification or compliance with rederal laws governing PCB content
of oil and oil -filled transformers.
REFERENCE: Final rule on PCB's per Environmental Protection Agency Part IV
Federal Register Vol. 44, Nos. 106, dated May 31, 1979
As part of our program for compliance with Federal Environmental Laws, we are
required to maintain and certify that our product and production oil system contains
less than 50 PPM of PCB's (Polychlorinated Biphenyls.)
This letter is to certify that CG Power Systems USA Inc supplies insulating oll-filled
equipment with oil which contains less than 1 PPM PCBs.
Our suppliers of oil have certified to us that no PCB's are introduced into the oil any
time during their processing.
We have no knowledge that CG Power Systems USA Inc has produced a product
containing over 50 PPM of PCBs. Our certification is maintained by ensuring that all
new oil received at our plant is PCB free, by periodic testing of samples from various
plant locations and requiring that returned product containing oil be certified to less
than 1 PPM PCB.
The serial numbers for certified transformers will be 89A-- or later. The first two
numbers are the year and the letter is the month of order entry.
We do not anticipate transmitting test results in the form of reports or guarantees for
specific individual units.
__A/ 14-�-
Jeff Barnes
Total Quality Manager
Fort Collins Utilities Transformer Bid Loss Data Sheet
FCU Stock #
13000015
# Units
Bid #:
Preparer Name :
Name
sally
Size
15DkVA
Date:
Date I,f,. Preparer Contact Num:
Number
495913092
NL Loss Cost
s 3.90
FL Loss Cost
230
Includes Winding's
Stray Losses &
Losses
Escalation
Losses Associated
associated
Base Bid
Base
Bid $ /
Guar No Load Guar Full Load Meet Space?
(Is / is not)
Guar Total with Auxiliary
Winding's with Auxiliary NL Loss' NL
FL Loss' FL
Evaluated
Extended Cost
Supplier
MIT / Mr#
Each
DeVWks
Loss Loss impedance (Yes / No)
a factor
Load Loss Devices (Yes / No)
Stray Losses Devices Loss Cost
Loss Cost
Bid
(Total $)
Supplier 1
Power
S
6,567.00 16-18 weeks
353 121n 2.1 S yes
is not
1572 -
r, (I $ 1,376.70
$ 2,803.70
$ 10,747.40
$ 85,371.00
Supplier 2
Mir 2
S
- -
0 0 0-00
-
0
0 0 $ -
IS -
IS -
$ -
Supplier 3
MIT 3
S
- -
0 0 0.00 -
-
0 -
0 0 $
$ -
$ -
IS -
2) Full load losses — it shall be clearly stated whether this number includes the winding's expected stray losses and losses associated with auxiliary devices
3) Winding's expected stray losses related to quoted transformer design
4) Losses associated with auxiliary devices such as fuses, breakers, switches, etc.
quoted loss values shall be corrected to a reference temperature of 85°C. Quotations submitted during the bid process without the required losses information shall be deemed unresponsive and are subject
rejection by the City of Fort Collins.
Fill out the information in the cells with blue text.
Save the file using your company name and the bid number and e-mail it to: purchasing@fcgov.com
(Example: TransfornerSales_Bid-58.xis)
Select Tools, Options
Select Security Tab
Type your password in the "Password to Open' field.
Re-enter your password to confirm it.
Important! Please remember to include this password in the bid information that will be sealed in the envelope that will be
unsealed at Bid Opening. This will secure your data until the time of the bid opening.
Save the file and e-mail it to: purchasing@fcgov.com
Fort Collins Utilities Transformer Bid Loss Data Sheet
FCU Stock #
T3000015
# Units
13
Bid #:
Preparer Name :
LaKetia Davis
Size
1500A
Date:
Preparer Contact Num:
3301-425-3151
NL Loss Cost
$ 3.90
FL Loss Cost
$ 2.30
Includes Winding's
Stray Losses a
Losses
Escalation
Losses Associated
associated
Base Bid
Base
Bid $ /
Guar No Load Guar Full Load Meet Specs?
(Is / Is not) Guar Total
with Auxiliary
Winding's with Auxlllary NL Loss' NL
FL Loss • FL
Evaluated
Extended Cost
Supplier
Mfr / Mfr#
Each
Del/Wks
Loss Loss Impedance (Yes / No)
a factor Load Lose
Devices (Yes / No)
Stray Losses Devices Loss Cost
Loss Cost
Bid
(Total $)
Howard Industrie Howard Indust,
$
6,116.00 f3-8 Wks ARO
333 1290 2.00 Yes,,
NO 1623 Yes
25 0 $
$ 2,967.00
$ 10,262.70
$ 79,508.00
Supplier 2
Mfr 2
$
- -
0 0 0.00 -
-
0 -
0 0 $ -
$
$
$ -
Supplier 3
Mfr 3
$
- -
0 0 000 -
-
0 -
0 0 $ -
$ -
$ -
$
Full load losses — it shall be clearly stated whether this number includes the winding's expected stray losses and losses associated with auxiliary devices
Winding's expected stray losses related to quoted transformer design
Losses associated with auxiliary devices such as fuses, breakers, switches, etc.
All quoted loss values shall be corrected to a reference temperature of 85"C. Quotations submitted during the bid process without the required losses information shall be deemed unresponsive and are subject
to rejection by the City of Fort Collins.
Fill out the information in the cells with blue text.
Save the file using your company name and the bid number and e-mail it to: purchasing@fcgov.com
(Example: TransformerSales_Bid_58.xls)
To protect this file, take the following steps:
1) Select Tools, Options
2) Select Security Tab
3) Type your password in the "Password to Open" field.
4) Re-enter your password to confirm it.
Important! Please remember to include this password in the bid information that will be sealed in the envelope that will be
unsealed at Bid Opening. This will secure your data until the time of the bid opening.
5) Save the file and e-mail it to: purchasing@fcgov.com
EXHIBIT A
BID ACKNOWLEDGEMENT
Contractor hereby acknowledges receipt of the City of Fort Collins Utilities' Request for Bids for
the Transformers and acknowledges that it has read and agrees to be fully bound by all of the
terms, conditions and other provisions set forth in the Bid. Additionally, the Contractor hereby
makes the following representations to Utilities:
a. All of the statements and representations made in this bid are true to the best of the
Contractor's knowledge and belief.
b. The Contractor has obtained all necessary authorizations and approvals that will enable
the Contractor to commit to the terms provided in this bid submittal.
c. This bid submittal is a firm and binding offer, for a period of 45 days from the date
hereof.
d. I further agree that the method of award is acceptable to my company.
e. 1 acknowledge receipt of _ addenda.
Contractor Firm Name: n��c�e s `�n_%Ve A F 1 o C�- c Cl op4�
Physical Address: ,Do 93rpmAa_Q Lnc t \ i cb gu(0�
Remit to Address:
Phone: —7 070- S S-0 - -7 D Q 1
Authorized Agent of Firm Name:
Signature of Authorized Agent:
Primary Contact for Project:
Title: c%o ,Sa i. o S Email Address: SL na\V N COOP
Phone: 7c)O - 990- —7041 Cell Phone:
8327 Transformers 150 kVA 3-Phase Page 4 of 31
8327 TRANSFORMERS, 150KVA
BID SCHEDULE
WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR
8327 TRANSFORMERS, 150KVA, THREE PHASE, PAD -MOUNTED PER THE BID
INVITATION AND ANY REFERENCED SPECIFICATIONS,
QUANTITY: DESCRIPTION:
13 ea. T3000015 TRANSFORMER, 150 kVA PAD -MOUNTED
COMPARTMENTAL TYPE, THREE PHASE DISTRIBUTION
WITH SEPARABLE INSULATED LOAD BREAK HIGH VOLTAGE
CONNECTORS. HIGH VOLTAGE RATING: 13200 GRDY/7620.
LOW VOLTAGE RATING: 208Y/120. SERIAL NUMBER 015 TO
BE IN ACCORDANCE WITH SPECIFICATION #368-300-015,
REVISION PP.
Please complete the Excel spreadsheet issued separately for
bid submittal. The spreadsheet MUST be submitted in Excel
format only. Failure to submit in the format requested may cause
the submittal to be deemed incomplete and may be subject to
rejection.
IF YOU ELECT TO PASSWORD PROTECT YOUR BID, PLEASE
NOTE THAT PASSWORD IN A SEPARATE EMAIL TO
ourchasing(a)fcgov.com at the time of bid submittal.
"Any surcharges or additional costs shall be noted & included in bid submittal.
Delivery lead time may be a consideration of bid award.
For purposes of warranty and service ONLY approved manufacturers or distributors authorized
by an approved manufacturer to serve the Fort Collins area may bid.
Awards from this bid will be based primarily on the evaluated bid price. Delivery lead times,
escalation and exceptions taken will also be considered. The City of Fort Collins reserves the
right to split the bid award in whatever percentages are most advantageous to the City.
Future orders of 150KVA THREE PHASE, PAD -MOUNTED may be authorized, at the option of
the City, from this bid for a period of five years after bid closing date. Satisfactory pricing, losses
and delivery are required for future orders based on this bid.
8327 Transformers 150 kVA 3-Phase Page 3 of 31
Howes Inc.
�I1:� 1.AJEiRllIREIIYLJU4 M.7:
}• 'nd(osmerDivision
Ro 3oa1b88
•
lawei h7S 39441-1588
Phcne. 601 425 3151
Fax 6C1 649 8090
SILICON
FOB: DESTINATION
VALIDITY:
30 DAYS
WESTERN UNITED ELEC SPY
PRICING:FIRM FOR QUOTED SHIPMENT
TERMS:
NET 30 DAYS
100 BROMLEY BUSINESS PKW
AGENT: POWER EQUIPMENT SPECIALS
INQUIRY:
CITY OF FORT
BRIGHTON, CO 80603
COLLINS
Item
ITEM 1
13
PRODUCT: 3-PHASE PADMOUNt ANSI C57.12.34 DEAD FRONT SINGLE VOLTAGE
KVA: 150 KVA
HV: 13200GRDY/7620 + GRD 95KV BIL
IV: 208Y/120 30KV BIL
TAPS: (2) 2-1,''2 ABOVE & BELOW
LOSSES: NO LOAD = 333, LOAD = 1290, TOTAL = 1623
IMPED = 2.0
OIL TYPE: MINERAL
QUOTED PER CUSTOMER SPEC DATED 5/9/14
EVALUATED: NO LOAD = 3.90 LOAD = 2.30
THREE PHASE PADMOUNT, DEAD FRONT, LOOP FEED.
2016 DOE COMPLIANT
**NOTE: GUARANTEED LOSSES QUOTED
**NOTE: TAKING EXCEPTION TO 4 WAY PALLET,
QUOTING RUNNERS FOR 2 WAY ENTRY.
ORDERS REQUIRING APPROVAL DRAWINGS: LEADTIMES QUOTED ASSUME THAT APPROVAL
DRAWINGS WILL BE SIGNED AND RETURNED TO HOWARD INDUSTRIES WITHIN TWO WEEKS OF
RECEIPT OF SAID DRAWING. SHOULD THE PROCESS REQUIRE ANY ADDITIONAL TIME BEYOND
THESE TWO WEEKS, THAT ADDITIONAL TIME WILL BE ADDED TO THE QUOTED LEADTIME.
TRANSFORMERS ON THIS QUOTATION ARE DESIGNED TO COMPLY WITH DOE EFFICIENCY
REQUIREMENTS EFFECTIVE FOR COWERED TRANSFORMERS COMPLETING MANUFACTURE BEGINNING
JANUARY 1, 2016.
UNCONTROLLED COPY LAST PAGH
UNLE55 VIEWED ON A PC FROM THE =Sham on Howardpdo Drlvo
QUOTATION
QUOTAI'10` DATE:06/06/2016
PAGE NO: 1
Shipment
Unit Price ARO
`116 06-08 WKS
SUBMITTED BY LAKETIA HILL
Neuesaa.eal
}
DESCRIPTION
DWG No.
HOWARD
NOT FOR CONSTRUCTION LAUREL,®WDIISTRINC. 440
THREE PHASE PAD DISTRIBUTION TRANSFORMERS
CUSTOMER : FORT COLLINS. CO.
6& SPEC. — DATED
o 0
KVA 150, 0 BIL 95 TAPS —
% HIGH VOLTAGE13200GRDY/7620
' LOW VOLTAGE
I— 1 ri APPROX. CORE AND COIL WEIGHT 1341
i I I I APPROX. TANK AND ACCESS. WEIGHT 1
I----------� GAL. OF OIL 31 APPROX, WEIGHT 1373
APPROX. TOTAL WEIGHT 4
o 0
0 2, REV. DATE DESCRIPTION p
ai A
NOTE. THE WEIGHTS AND DIMENSIONS ARE APPROXIMATE
AND SUBJECT TO CHANGE WITHIN THE CUSTOMER
SPECIFIED LIMITS. APPROVAL DRAWINGS WITH
THE ACTUAL WEIGHTS AND DIMENSIONS WILL BE
2S PROVIDED UPON REQUEST AFTER RECEIPT OF ORDER.
41 5 7 NOTE: (1) DIMENSIONS IN INCHES
3g (2) WEIGHTS IN POUNDS
12
Tl 10
50 8
2
22
o L 4.
m "'A "is
O 1Sd 1Y1 o
vA "®° xwro x2 cu 21
3
sIr N
212 o
IL
4.
4 14 51 15 t4 13
1. 4, 47.65
_
r
00
N
W
1
LV BUSHING & 4—HOLE SPADE
2
LV SPADE SUPPORT
3
1 2-13 GROUND PAD
4
HV BUSH DF WELL
5
LOADBREAK PARKING STAND
7
NP ON DOOR, SERIAL ON TANK
8
TANK
10
HANDHOLE &SECURITY COVER
12
LIFTING LUGS
13
JACKING PROVISIONS
14
1/2-13 GROUND PAD
15
1 IN PIPE PLUG — VERA SEAL
21
PADLOCKABLE DOOR HANDLE
22
3 PT LATCH PENTA SEC BOLT
24
12 IN REMOVABLE SILL
25
METAL LV—HV BARRIER
39
CUP ON DRIP SHIELD
41
BAYONET FUSE HOLDER
47
IFD NON—RESETTABLE DEVICE
48
DIAL THERM W MAX POINTER
50
OIL LEVEL PLUG
51
TAP CHANGER HANDLE
52
10 UPPER FILTER PRESS CONN
SPECIAL NOTES
A
BAY—O—NET FUSE
B
CURRENT LIMITING FUSE
n
E
T
NO
DWG
BY
HL
DATE, 05 31 is
PP
BYd
CC. 745
0.050 91506311S,6M, 16, O,FO8 ,169, 34, 45 524773, 626571.2, 321.2. 1263 59000000.210
No. HL8323001
THREE PHASE r1 O YY ARD M]I DVS RIES USAREL MS 39440
TRANSFORMER i7 YY 1111 11V
DOE COMPLIANT
lJ 1 i� l
1
READ INSTRUCTION HI
105 BEFORE OPERATING MFG
KVA 150
BIL HV 95 LV 3OKV 2.0%mp
HV 132000RDY/7620
Lv208Y/120 AMPS 416
LB TANK 831 C&C 1341 T9,
II 18,3 GAL TOTAL 3545 LBS
CONT 65 'C RISE CLASS ONAN 60HZ
TANK DESIGNED FOR +7 PSIG
F1 CLF PARTIAL RANGE
—
F2 BAYONET FUSE \
i o
CONTAINS NO DETECTABLE LEVEL OF PCB (LESS
\
THAN 2 PPM) AT THE TIME OF MANUFACTURE. \O J
F
V13LTAGE P13S AMPS
o FL
13860 1/A 6.25
eHV LV
AL
13530 2/B 6.40 H x
13200 3/c 6.56
AL
'A H ; I x2x3
Ho xo
12870 4/D 6.73
12 1 H1 H xt x
0
SER. NO. BAR CODE
CAT. N0. BAR CODE
SER. NLT,
HOWARD M) INDUSTRIES INC.
LAUREL, MISS. USA 39440
MFG. OF DISTRIBUTION TRANSFORMERS
NAME: LASER NAME PLATE cc 857
DESCR: LF/TP/2FUSE Y—Y
ID 3CHLO136 DWG: HL8323001
E VI S I O N I BY APP SCALE 1.000 1 DWG BY CHK BY DATE1 /16
CENTRAL MOLONEY,
INC.
PAGE: 1
TO: DAVE BAUER @ PETERSON
SUBJECT: CITY OF FORT COLLINS
CUSTOMER NAME:CITY OF FORT COLLINS
CUST:CITY
WE ARE PLEASED TO GIVE YOU THE FOLLOWING QUOTATION:
DATE: 05/31/16
FROM: LEESA KAPPLER
INQUIRY NO:8327 5-31-16
QUOTATION NO:69100
ITEM I QTY I KVA I TYPE ! PRIMARY I SECONDARY iCORE I COPPER ISHIP WEEKS UNIT -PRICE
EFF
BUSH I TAPS
ITEM I QTY I KVA I TYPE I PRIMARY I SECONDARY ICORF. I COPPER ISHIP WEEKSI UNIT -PRICE
COMMENTS: QUOTE VALID FOR 30 DAYS. DOE 2016 COMPLIANT
TAPS
PRICE INCLUDES THE IFD.
STOCK -CODE
%I Z
PRICES ARE FIRM FOR DELIVERY QUOTED UNLESS OTHERWISE STATED. THIS QUOTATION IS VALID FOR ACCEPTANCE WITHIN THIRTY(30) DAYS FROM DATE HEREOF
AND, IN THE MEANTIME, IS SUBJECT TO CHANGE UPON NOTICE. STANDARD TERMS AND CONDITIONS OF SALE FORM 300322, WILL APPLY. PLEASE NOTE THAT TERMS
ARE NET THIRTY(30) DAYS AFTER DATE ON INVOICE. FAX:(870)543.6560 PHONE:(870)534-5332 P.O. BOX 6608 PINE BLUFF, AR 71611