HomeMy WebLinkAboutRESPONSE - BID - 8259 TRANSFORMERS 500 & 750 KVA THREE PHASE PADMOUNTED (2)FCU Stock # T3000050 It Units 6 Size 500kVA NL Loss Cost $ FL Loss Cost S Supplier MIU Will Fort Collins Utilities Transformer Bid Loss Data Sheet Bid n: Preparer Name: Mark Baragary Date: 1 N1Preparer Contact Num: 303-217-7516 Includes Winding's Stray Losses & Escalation Losses Associated Base Bid $ / Guar No Load Guar Full Load Meet Specs? (Is / la not) Guar Total with Auxiliary Each DeVWks Loss Loss Impedance (Yes / No) a factor Load Loss Devices (Yes / No) 10,1g5.30 7-9 Woeks i77 '150.7 3,02 Yos Not 5071 Yes Losses associated Winding's with Auxiliary NL Lon ' NL Stray Losses Devices Loss Cost IW 0 $ 2) Full load losses — it shall be clearly stated whether this number includes the winding's expected stray losses and losses associated with auxiliary devices 3) Winding's expected stray losses related to quoted transformer design 4) Losses associated with auxiliary devices such as fuses, breakers, switches, etc. Base Bid FL Loss' FL Evaluated Extended Cost Loss Cost Bid (Total $) $ - $ 10,105.30 $ 60,631.80 All quoted loss values shall be corrected to a reference temperature of 85°C. Quotations submitted during the bid process without the required losses information shall be deemed unresponsive and are subject to rejection by the City of Fort Collins. 1) Fill out the information in the cells with blue text. 2) Save the file using your company name and the bid number and e-mail it to: purchasing@fcgov.com (Example: TransfornerSales_Sid_58.xis) To protect this file, take the following steps: 1) Select Tools, Options 2) Select Security Tab 3) Type your password in the "Password to Open" field. 4) Re-enter your password to confirm it. Importantl Please remember to include this password in the bid information that will be sealed in the envelope that will be unsealed at Bid Opening. This will secure your data until the time of the bid opening. 5) Save the file and e-mail it to: purchasing@fcgov.com FCU Stock # T3000075 # Units Size 750 kVA NL Loss Cost $ FL Loss Cost $ Supplier Mir /Mh# ABB 750KVA Fort Collins Utilities Transformer Bid Loss Data Sheet Bid a: Preparer Name: Mark Baragary Date: ,. , Preparer Contact Num: 303-217-7516 Includes Winding's Stray Losses a Escalation Losses Associated Base Bid $ / Guar No Load Guar Full Load Meet Specs? (Is / Is not) Guar Total with Auxiliary Each DBI/Wks Loss Loss Impedance (Yes / No) a factor Load Loss Devices (Yes / No) S 16.289.50 9- 11 weeks 57n Yos Not 5731 Ye, Losses associated Winding's with Auxiliary NL Loss' NL Stray Losses Devices Loss Cost 607 (I $ Quoted losses submitted by manufacturers shall include the following: 1) No load losses 2) Full load losses — it shall be clearly stated whether this number includes the winding's expected stray losses and losses associated with auxiliary devices 3) Winding's expected stray losses related to quoted transformer design 4) Losses associated with auxiliary devices such as fuses, breakers, switches, etc. Base Bid FL Loss' FL Evaluated Extended Cost Loss Cost Bid (Total $) $ - $ 16,209.50 $ 48,868.50 All quoted loss values shall be corrected to a reference temperature of 85'C. Quotations submitted during the bid process without the required losses information shall be deemed unresponsive and are subject to rejection by the City of Fort Collins. Fill out the information in the cells with blue text. Save the file using your company name and the bid number and e-mail it to: purchasing@fcgov.com (Example: Tmnsformer5ales_Bid-58.xis) 1) Select Tools, Options 2) Select Security Tab 3) Type your password in the "Password to Open" field. 4) Re-enter your password to confirm it. Importantl Please remember to include this password in the bid information that will be sealed in the envelope that will be unsealed at Bid Opening. This will secure your data until the time of the bid opening. 5) Save the file and e-mail it to: purchasing@fcgov.com J AL It It ^,.,. Neg #: 1602910335 City of Fort Collins / Wesco Distribution, Inc / City of Fort Collins To: City of Fort Collins 11333 East 55th Ave Denver CO 80239 Phone: Fax: From: Mark Baragary Wesco Distribution, Inc. Phone: 303-217-7516 Fax: 303-217-7535 Email: mbaragary@wesco.com Item Alt Oty Description Price Each (USD) 10 3 750 KVA Liquid Filled Padmounted Transformer $16,289.50 DTR 2401, Jefferson City, USA (9AAE300179), PDC: 9AAC30400147, DTAN-L3S135 500 KVA Liquid Filled Padmounted Transformer 20 6 DTR 2401, Jefferson City, USA (9AAE300179). PDC: 9AAC30400147, DTAN-L3S135 $10,105.30 ABB Page I of 6 2/260-016 NOTICE-- This document may contain confidential and privileged information for the sole use of the intended recipient. If you are nor the intended recipient You may not review, copy or distribute this message. Any review or distribution by others is .strictly prohibited. If you are not the intended recipient, please contact the sender immediately and delete all copies. Neg #: 16Q2910335 City of Fort Collins / Wesco Distribution, Inc / City of Fort Collins ITEM QTY kVA EACH (USD) Altitude I NIL I LL I TL Conductor 10 3 750 $16,289.50 3300 1 994 0 20 14737 @ 85 1 5731 AI/AI nit ITEM %Z Shipment 10 5.79 6946 9-11 Weeks Quoted loss values are subjected to ANSI Test Tolerances. All weights and dimensions are approximate. Lead times for orders subject to drawing approval will be confirmed upon receipt of approval and release for manufacturing. Description: Type Liquid -Filled MTR Padmounted Transformer Fluid Mineral Oil Core Grain Oriented Steel Phase 3 Phase Frequency 60 Hz Average Winding Rise 65 °C Ambient Temperature 30 °C High Voltage 1320OGrdY/7620 High Voltage Taps +2 -2 2.5% High Voltage BIL 95kV BIL Low Voltage 208Y/120 Low Voltage BIL 30kV BIL Neutral HOXO bushing with ground strap Feed Configuration Loop feed Color Desert tan paint (Munsell 1 OYR 6.0/3.0) Customer Specification 368-300 Rev PP, 5/8/2014 Features (included in price): TANK & CABINET • Undercoat • Penta-head cabinet handle bolt BUSHINGS • Threaded stud LV bushings x 4 • Loadbreak Inserts (dead front) x 6 • HV Bushing pattern per ANSI standard C57.12.26, Fig 6A & 7 (5.0" spacing) • 200 amp HV bushing wells x 6 • 6-hole NEMA spade terminals x 4 • Spade Supports • ANSI C57.12.26 Fig 7&8a specific stgrd LV bushing pattern FUSES • Fused bayonet no isolation link x 3 • Oil -immersed partial range current limiting fuse x 3 MONITORING • Internal Fault Detector (IFD) ABB Page 2 of 6 2/26/2016 NOTICE— This document mar contain confidential and privileged inforn nation for the sole use of the intended recipient. If you are not the intended recipientyou may not review. coPy or distribute this message. Any review or distribution by others is strictiv prohibited. if you are not the intended recipient, please contact the .tender immediately and delete all copies. AL N! I! rRIL111111/ Neg #: 16Q2910335 City of Fort Collins / Wesco Distribution, Inc / City of Fort Collins • Liquid level gauge • Pressure relief valve • Dial type thermometer • Provisions for pressure/vacuum gauge FITTINGS • Drain valve and sampler MARKINGS • Non -PCB label OTHER • Bushing leads long enough for field replacement • LV compartment width min 28", LV bushing height 46", LV spacing per page 14, Max dims per pad drawing on page 15 • 9.5" x 17.5" Tank Handhole Cover • 18" deep cabinet • DOE Efficiency (2016) Item 10 General Comments and Exceptions • Stray Losses Item 10 - 660 Watts Ass Page 3 of 6 2/26/2016 NOTICE- This document mac contain confidential and privileged information for the sole use of the intended recipient. If you are not the intended recipient you map not review. cope or distribute this message. Anr review or distribution by others is strictly prohibited. If you are not the intended recipient, please contact the .sender immediateh• and delete all copies. /L 1! 1! P%IPIP Neg #: 16Q2910335 City of Fort Collins / Wesco Distribution, Inc / City of Fort Collins ITEM QTY kVA EACH USD) Altitude NIL LL TL Conductor 20 6 500 $10,105.30 A 3300 1527 @ 20 4544 ® 85 5071 AI/AI nit ITEM %Z Shipment 20 1 3.02 1 5545 7-9 Weeks Quoted loss values are subjected to ANSI Test Tolerances. All weights and dimensions are approximate. Lead times for orders subject to drawing approval will be confirmed upon receipt of approval and release for manufacturing. Description: Type Fluid Core Phase Frequency Average Winding Rise Ambient Temperature High Voltage High Voltage Taps High Voltage BIL Low Voltage Low Voltage BIL Neutral Feed Configuration Color Customer Specification . Liquid -Filled MTR Padmounted Transformer Mineral Oil Grain Oriented Steel 3 Phase 60 Hz 65 °C 30 °C 1320OGrdY/7620 +2 -2 2.5% 95kV BIL 208Y/120 io 11VA1:311111 HOXO bushing with ground strap Loop feed Desert tan paint (Munsell 1 OYR 6.0/3.0) 368-300 Rev PP, 5/8/2014 Features (included in price): TANK & CABINET • Undercoat • Penta-head cabinet handle bolt BUSHINGS • Threaded stud LV bushings x 4 • Loadbreak Inserts (dead front) x 6 • ANSI C57.12.34 Fig 98,11 HV bushing pattern (minimum) • 200 amp HV bushing wells x 6 • 6-hole NEMA spade terminals x 4 • Spade Supports • ANSI C57.12.26 Fig 38,4a minimum stgrd LV bushing pattern FUSES • Fused bayonet no isolation link x 3 • Oil -immersed partial range current limiting fuse x 3 MONITORING • Internal Fault Detector (IFD) • Liquid level gauge ABB Page 4 of 6 2/26/2016 NOTICE— This document nmY contain confidential and privileged information for the .sole use n(the intended recipient. Ifyou are not the intended recipient you nurc not review. copy or distribute this message. Anv review or distribution by others is strictly prohibited If you are not the intended recipient please contact the .sender immediately and delete all copies. A MIND P119111 Neg #: 1602910335 City of Fort Collins / Wesco Distribution, Inc / City of Fort Collins • Pressure relief valve • Dial type thermometer • Provisions for pressure/vacuum gauge FITTINGS • Drain valve and sampler MARKINGS • Non -PCB label OTHER • Bushing leads long enough for field replacement • LV compartment width min 28", LV bushing height 31 ", LV spacing per page 14, Max dims per pad drawing on page 15 • 9.5" x 17.5" Tank Handhole Cover • 18" deep cabinet • DOE Efficiency (2016) Item 20 General Comments and Exceptions • Stray Losses Item 20 - 190 Watts KVA FEED A 9 C D E F WT 750 Loop 68 82 60.8 50.8 66 18 7400 (Dead) 500 Loop 56 68 58.8 48.8 62 18 5600 (Dead) All weights and dimensions are approximate. Dimensions may change to meet specific customer requirements. Weights are in pounds. Dimensions are in inches. Cooling fins may be required on the back and/or side of the tank if necessary. Maximum cooling fin depth is 16". Top Yew FINS L - -B FINS TANK FINS CABLE OPENING ABB Page 5 of 6 2/26/2016 NOTICE --This document nuty contain confidential and privileged information for the sole use of the intended recipient. If you are not the intended recipient you nmv not review, ropy or distribute this message. Any review or distribution by others is strictly prohibited. If you are not the intended recipient. please contact the sender immediately and delete all copies. A It it P♦ Ip l! Neg #: 1602910335 City of Fort Collins / Wesco Distribution, Inc / City of Fort Collins Side Yew Front View City of Fort Collins 2/26/2016 1 3-Phase Padmounted Transformer I ABB Inc, Jefferson City, MO ABB Page 6 of 6 2/26/2016 NOTICE-- This document mar contain confidential and privileged information for the sole use of the intended ret ipient. If you are not the intended recipient You may not rn'iew. copy or distribute this message. My review or distribution by others is strictly prohibited. If you are not the intended reripinu, please contact the sender immedtarelr and delete all copies.