Loading...
HomeMy WebLinkAboutBID - 8050 EXTERIOR SIGNAGE AT FORT COLLINS MUSEUM OF DISCOVERY (2)ADDENDUM NO. 1 SPECIFICATIONS AND CONTRACT DOCUMENTS Description of 8050 EXTERIOR SIGNAGE AT FORT COLLINS MUSEUM OF DISCOVERY BID OPENING: 3:00 P.M. (our clock), JANUARY 28, 2015 To all prospective bidders under the specifications and contract documents described above, the following changes/additions are hereby made and detailed in the following sections of this addendum: Exhibit A - Revised Bid Schedule Exhibit B - Questions and Answers Exhibit C - Drawings Please contact John Stephen, CPPO, LEED AP, Senior Buyer at (970) 221-6777 with any questions regarding this addendum. RECEIPT OF THIS ADDENDUM MUST BE ACKNOWLEDGED BY A WRITTEN STATEMENT ENCLOSED WITH THE BID/QUOTE STATING THAT THIS ADDENDUM HAS BEEN RECEIVED. Financial Services Purchasing Division 215 N. Mason St. 2nd Floor PO Box 580 Fort Collins, CO 80522 970.221.6775 970.221.6707 fcgov.com/purchasing 8050 Exterior Signage at Fort Collins Museum of Discovery Page 1 of 24 Exhibit A Addendum 1 Bid Schedule Service provider agrees that they will provide final design, complete all manufacturing including installation. All mobilization, equipment, labor and fuel is included in your lump sum bid for a turnkey job. Lump Sum with back lighting for south face only $____________________________ In Words______________________________________________________________ Lump Sum without back lighting for both east and south face $____________________ In Words______________________________________________________________ FIRM NAME Are you a Corporation, Partnership, DBA, LLC, or PC SIGNATURE: PRINTED: ADDRESS: CITY, STATE, ZIP: PHONE: EMAIL: 8050 Exterior Signage at Fort Collins Museum of Discovery Page 2 of 24 Exhibit B - Questions and Answers Owner responses in blue. 1. “At the meeting there seemed to be a lot of concern about the number of penetrations into the building. Penetrations can be reduced significantly by mounting the letters to a backer panel. This method does however change your design slightly. Each letter will have 2-3 penetrations and the option with the backer panel would have 6. The letters would still stand off the panel and be reverse lit. Please let me know if I should include an additional bid for this method. “ For the backlit option, our preference is a “halo-lit” effect similar to what’s shown in the examples below –rather than a panel backer or chaseway(s). We recognize this approach will require more penetration points into the wall. However, regardless of whether the sign is backlit or not, penetrations will be required and therefore certain conditions must be met. The concrete wall panels at this location are pre- stressed which means they have strands of metal running through them for structural support. Spacing is usually fairly typical but there can be variations within each panel and we must avoid drilling into any of the strands. As long as any penetrations don’t hit the pre- stressed strands and they are caulked/sealed sufficiently to prevent moisture getting into the walls, we can do as many penetrations as required. The selected sign fabricator will be required to seek approval in advance on all installation drawings to ensure that no strands are compromised. Drawings will need to identify exactly where the suggested penetrations would take place. The consultant advising this project is Mike Rettig of EnCon Colorado (formerly Stresscon) and he can be reached at 303-298-1900. 8050 Exterior Signage at Fort Collins Museum of Discovery Page 3 of 24 2. Color of LEDs if white what kelvin temp? 6,000-8,000K range (neutral white, not too blue or yellow) 3. Thickness of material for FCOs (Flat Cut Out Lettering) For bidding purposes, please use ¼” thick aluminum for all signs. After award, sign fabricator to advise thickness on larger south-facing signs (backlit or not) since it has larger elements and may require thicker material. 4. Voltage requirements if illuminated? Provide industry standard for bidding purposes. After award, sign fabricator to advise client on this requirement. 5. Sealant required for penetrations of cast wall? Penetrations must be caulked/sealed sufficiently to prevent moisture getting into the walls. Caulk must be minimum industry standard. 6. Is cast wall pre -stressed? The concrete wall panels at this location are pre-stressed which means they have strands of metal running through them for structural support. Spacing is usually fairly typical but there can be variations within each panel and we must avoid drilling into any of the strands. As long as any penetrations don’t hit the pre-stressed strands and they are caulked/sealed sufficiently to prevent moisture getting into the walls, we can do as many penetrations as required. 7. Hours of access to the archive room? Building access outside of normal operating hours can be arranged on request. Fabricator must provide an installation schedule. 8. Procedure for penetrating roof membrane? There should be no reason for penetrating the roof membrane for this project. In the case of the exterior walls, fabricator will be required to seek approval in advance on all installation drawings to ensure that no pre-stressed strands in the wall are compromised. Drawings will need to identify exactly where the suggested penetrations would take place. The consultant advising this project is Mike Rettig of EnCon Colorado (formerly Stresscon) and he can be reached at 303-298-1900. 8050 Exterior Signage at Fort Collins Museum of Discovery Page 4 of 24 9. The signage on the east facing elevation view specifies non-backlit. Should this sign be made of ¼” thick aluminum material? Yes. 10. The signage on the south facing elevation specifies halo lit illumination. The Bid Schedule requests lump sum pricing with back lighting and without. If we do an option without the backlighting, should the price still include the letters being 3 ½” deep with a clear lexan back, or would you like the non-lit option to be the same material thickness as the east facing elevation sign? The non-lit option for the south facing sign is to be fabricated in the same manner as the other non-lit signage. Please use ¼ thickness for the bid. 11. On the south facing elevation sign, should we assume that there is adequate access behind the wall for the wiring and power supply? And if so, will we need to make a cover over this wiring and power supply? See attached building drawings for access queries. Wiring and power supply must be hidden as much as possible and approved by owner prior to installation. 12. The Fort Collins Museum signage, as designed, will need a variance to allow a proposed sign up to 12’ tall on the wall. The limit per the Fort Collins sign code is 7’ tall, as confirmed yesterday by Noah Beals in Zoning. The variance approval is not guaranteed, and will add about 2 months to the schedule. Clarification: The zoning office is allowing the letters to be up to 7 feet tall and the logo to be up to 7 feet tall as shown on our drawings. Per communication from Noah Beals 21JAN2015, the design will be approved as shown. 13. Is a 3'' return on the illuminated reverse channel letters acceptable? Yes. 14. Is an acrylic polyurethane paint finish acceptable on all characters (illuminated and non- illuminated)? Finish shall be powder coating or comparable treatment for durability reasons. 15. Will an interior/back side of wall cover up wire way, painted to match wall be acceptable for the illuminated sign? Our preference is no chaseways, wireways or visible conduit. This will be approved through shop drawings. 16. Will .25'' aluminum be acceptable for the flat cut out non illuminated signage? Yes. 17. Please verify, Lump Sum with back lighting - this line item will include all the characters of the south facing sign to have halo illumination effect (east facing sign not included in this line item) Correct – east facing sign is non backlit in all scenarios. 8050 Exterior Signage at Fort Collins Museum of Discovery Page 5 of 24 18. Please verify, Lump Sum without back lighting - this line item will include east facing sign characters only (south facing sign not included in this line item) Please provide a quote for both south and east facing sign to be 100% non-backlit, and a quote for east facing sign to be non-backlit and south facing sign to be backlit. In all scenarios, the east facing sign is non-backlit. 19. Will sign permit be a "no cost" from city building dept.? A permit will be required and is the responsibility of the fabricator to procure at regular cost. 8050 Exterior Signage at Fort Collins Museum of Discovery Page 6 of 24 VERSION DATE AUTHOR STATUS EXTERIOR SIGNAGE - EAST FACING SIGNAGE (NON-BACKLIT) Exterior Signage - East Face Fort Collins Museum of Discovery 84" 76" 66" Bid 8050 Exterior Signage at Fort Collins Museum of Discovery GLAZING 4477 24" 30" 4" Sizes are approximate (+/- 2”) for cost estimating purposes only. Exhibit C 8050 Exterior Signage at Fort Collins Museum of Discovery Page 7 of 24 DN DN UP UP DN DN DN DN DN DN DN DN DN DN DN DN DN CODE PLAN GRAPHICS LEGEND 152 COMBINED OCCUPANT LOAD FROM MULTIPLE SPACES 45 M DOOR RATING (IN MINUTES) FIRE RESISTANCE DESIGNATIONS FW FIRE WALL (IBC SECTION 705) FB FIRE BARRIER (IBC SECTION 706) SE SHAFT ENCLOSURE (IBC SECTION 707) FP FIRE PARTITION (IBC SECTION 708) SB SMOKE BARRIER (IBC SECTION 709) SP SMOKE PARTITION (IBC SECTION 710) SP SMOKE PARTITION - E OCCUPANCY (IBC SECTION 508.2.2.1) D C B 7 8 9 AREA OLF OCC EXITS 2,861 SF ROOF DECK 302 96 2 30 AREA OLF OCC EXITS 617 SF CONFERENCE 301 42 1 15 B A-3 90 48 90 118 202 D C B 7 8 9 AREA OLF OCC EXITS 1,211 SF F E D C B A 6 7 8 9 10 G LEVEL ONE RCP- AREA A - A3.1a LEVEL ONE RCP- AREA B - A3.1b LEVEL ONE RCP - AREA A - A3.1a LEVEL ONE RCP - AREA B - A3.1b 1 A4.2.1 1 A4.2.2 3' - 2 3/4" 5' - 5 3/8" COLLECTION STORAGE 128A ELEC 122 HALL 121 REFERENCE 118 VOLUNTEER WORK 120 LOBBY 100 VEST 101A NA 101 GIFT SHOP 102 STOR 104A WORK ROOM 111 STORAGE 112 FAMILY LAV 115 WOMEN 113 MEN 114 MDF / IT 117 MEN 107 WOMEN 108 CLASSROOM LOBBY FFE 100' - 0" UPPER ROOF 144' - 0" A B C D E F G GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" METAL PANEL COLORED PRECAST GLAZING PARTIAL ELEVATION - 2 / A4.1.3 T.O. PARAPET 120' - 0" 16' - 0" ROOF BEYOND G1 G1 G1 G1 G1 H2 H1 H3 G3 G2 G3 HORIZONTAL REVEAL METAL COPING H1 S1 STUCCO OVERFRAME MEZZANINE 119' - 7" A6 A5 T.O. UPPER PARAPET 147' - 7" B12 B12 1 A9.2.3 H 19 21 9 A5.1.1 31 7' - 3 5/8" 34 1' - 5 1/2" 49 STUCCO STUCCO REVEALS - MATCH PRECAST REVEAL ELEVATIONS 96 2' - 6" 7' - 6" 103 108 122 7 A10.1.7 140 369 LOBBY FFE LOBBY FFE 100' - 0" UPPER ROOF 144' - 0" 2 3 4 5 6 7 8 9 10 GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" 1 METAL PANEL COLORED PRECAST GLAZING 2 3/8" / 12" PARTIAL ELEVATION - 9 / A4.1.3 T.O. PARAPET 120' - 0" H1 H1 G1 G1 G5 G1 S2 2 A4.2.1 Sim REVEAL STUCCO 6 A6.2.1 A6 A4 T.O. UPPER PARAPET 147' - 7" B11 B10 8 A5.1.1 STUCCO REVEALS - MATCH PRECAST REVEAL ELEVATIONS (ALL THREE SIDES OF INSET) 96 STUCCO REVEALS - MATCH PRECAST REVEAL ELEVATIONS (ALL THREE SIDES OF INSET) 96 120 134 10 A9.3.3 1 RFI 0345 A1 158 177 584 LOBBY FFE 100' - 0" UPPER ROOF 144' - 0" G F E D C B A GALLERY FFE 97' - 0" LOBBY FFE 100' - 0" UPPER ROOF 144' - 0" A B C D E F G GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" 115' - 0" 1 A4.2.1 4" / 12" T.O. PARAPET 120' - 0" A5.1.1 1 Sim COLLECTION STORAGE 128 114' - 11" T.O. UPPER PARAPET 147' - 7" 1 A9.2.3 H 1 RFI 0197 A1 7 A10.1.7 LOBBY FFE 100' - 0" UPPER ROOF 144' - 0" 2 3 4 5 6 7 8 9 10 GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" 14' - 7" 2 7/16" / 12" A9.0.1 7 T.O. PARAPET 120' - 0" A5.1.1 3 Sim COLLECTION STORAGE 128 TRAVELING EXHIBITS 127 ARTIFACT PROCESSING 131 LOBBY FFE 100' - 0" UPPER ROOF 144' - 0" GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" LOBBY 100 T.O. PARAPET 120' - 0" DOME M02 VEST 101A 114' - 1 3/4" T.O. UPPER PARAPET 147' - 7" A9.2.1 3 A5.1.2 2 623 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 2/1/2012 9:27:45 AM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt 1/8" = 1'-0" FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL/KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS BUILDING SECTIONS A4.2.2 FORT COLLINS DISCOVERY MUSEUM DS 1 SECTION 1/8" = 1'-0" - DIAGONAL LOBBY FFE 100' - 0" LOWER ROOF 116' - 0" A GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" T.O. PARAPET 120' - 0" A9.2.1 1 TYP. PLANTING TRELLIS RE: 11/A9.0.1 TYP. EXT. PRECAST WALL RE: 3/A9.0.1 TYP. GRADE BEAM RE: 9/A9.0.1 TYP. TPO ROOF ASSEMBLY RE: 6/A9.0.1 A9.1.1 3 FOUNDATION DRAIN METAL PRECAST CAP 30 LOBBY FFE 100' - 0" LOWER ROOF 116' - 0" GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" T.O. PARAPET 120' - 0" A9.2.1 1 TYP. PLANTING TRELLIS RE: 11/A9.0.1 TYP. EXT. PRECAST WALL RE: 2/A9.0.1 TYP. GRADE BEAM RE: 9/A9.0.1 TYP. TPO ROOF ASSEMBLY RE: 6/A9.0.1 A9.1.1 2 METAL PRECAST CAP OVERFRAME MEZZANINE 119' - 7" 30 LOBBY FFE 100' - 0" GALLERY FFE 97' - 0" T.O. PARAPET 120' - 0" A9.2.1 7 1' - 8 1/4" 4' - 6 3/4" SPANDREL GLASS TYP. ENCORE STOREFRONT FRAMING/GLAZING VESTIBULE 126A 3 5/8" STUD FRAMING A9.2.3 2 FULLY RECESSED HEATER RE: MECH 8' - 0" 120 2" F.V. 12' - 5 3/4" 10'-0" TYP. A9.3.3 8 144 1 3/4" 9 A9.3.3 158 A9.3.3 13 ALIGN 177 LOBBY FFE 100' - 0" OVERFRAME MEZZANINE 119' - 7" 3 A5.1.2 A9.3.3 2 A9.3.3 1 A9.3.1 4 125 149 3 RFI 252.1 A2 12' - 0" 10' - 0" 3 RFI 360.1 A2 LOBBY FFE 100' - 0" OVERFRAME MEZZANINE LOBBY FFE 100' - 0" UPPER ROOF 144' - 0" D C B A GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" T.O. WINDOW 108' - 0" B.O. WINDOW 102' - 6" T.O. WINDOW 140' - 0" T.O. P/C 132' - 6" T.O. P/C 129' - 2" 2 A5.1.1 3 A5.1.1 PRECAST CAP 3 A6.2.4 9 A9.5.1 3 A9.5.2 OVERFRAME MEZZANINE 119' - 7" T.O. UPPER PARAPET 147' - 7" 1 A9.2.3 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 2/1/2012 8:44:58 AM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt 1/4" = 1'-0" LOBBY FFE 100' - 0" G F E D GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" 1 A4.2.3 10" TALL SS LETTERS 2 A4.2.3 3 A4.2.3 10' - 0" 8' - 2" 9' - 10" STUCCO STUCCO 3 A9.5.2 13 A9.5.3 14 A9.5.3 8 A9.5.3 9 A9.5.3 OVERFRAME MEZZANINE 119' - 7" T.O. UPPER PARAPET 147' - 7" H 7 10 A10.1.7 A10.1.7 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 2/1/2012 8:41:49 AM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt 1/4" = 1'-0" LOBBY FFE 100' - 0" UPPER ROOF 144' - 0" 7 9 8 10 GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" T.O. PARAPET 120' - 0" STUCCO PRECAST 10 A9.5.1 14 A9.5.3 6 A6.2.1 8 A9.5.3 9 A9.5.3 OVERFRAME MEZZANINE 119' - 7" T.O. UPPER PARAPET 147' - 7" 8 A5.1.1 5 RFI 0334 A1 1 PR 0021 A2 8 9 A10.1.7 A10.1.7 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 2/1/2012 8:50:59 AM 3 3/4" - 5 1/2" EXST'G. CONCRETE OR MASONRY WALL #5136 SPACER - 1/2" x 1 1/2" DIA. - BLACK UHMW PLASTIC, TYP. #5132R MOUNTING CLIP, TYP. 3" THICK greenscreen PANEL, TYP. EXPANSION ANCHOR BY OTHERS - MIN. 550 LBS. PULL OUT 2 _15 _ 16 " 3/4" - 2 1/4" VARIES C L CL 5/8" GYP. BD. 6" METAL STUD 5/8" EXT. GYP. SHEATHING WEATHER BARRIER 2" RIGID INSUL. (2 LAYERS, SHIPLAP @ CURVED AREAS), R10.0 MIN. SPRAY FOAM INSULATION (R-15.0 MIN) 5/8" GYP. BD. 6" METAL STUD SPRAY FOAM INSULATION 5/8" EXT. GYP. SHEATHING REVEAL W.O. - SUPERIOR "SIV" (OR EQUAL) - WIRE TIE TO LATH 3 COAT STUCCO SYSTEM 3 COAT STUCCO SYSTEM WEATHER BARRIER 2" RIGID INSULATION (2 LAYERS, SHIPLAP @ CURVED AREAS), R10.0 MIN. 7 1/4" 2" 3/4" +/- 10" +/- PRECAST WALL PANEL, RE: STRUCT. 3.5" SPRAY FOAM INSULATION (R-25.0 MIN) 3 5/8" METAL STUD 5/8" PLYWOOD BACKING WHERE OCCURS, RE: A10.1.3 1' - 4 1/4" 5/8" GYP. BD. 3/8" 3/8" 6" TYP. EXT. PRECAST WALL, RE: 2/A9.0.1 2" RIGID INSULATION DAMP PROOFING GROUT, RE: STRUCT. TYP. GRADE BEAM, RE: 9/A9.0.1 & STRUCT. 12" CONC. SLAB, RE: STRUCT. 2" MUD MAT VAPOR RETARDER SEALANT RUBBER BASE, RE: SPEC. 30 TYP. EXT. PRECAST WALL, RE: 2/A9.0.1 2" RIGID INSULATION GROUT, RE: STRUCT. TYP. GRADE BEAM, RE: 9/A9.0.1 & STRUCT. ISOLATION JOINT EXT. PAVING, RE: LANDSCAPE 12" CONC. SLAB, RE: STRUCT 2" MUD MAT VAPOR RETARDER DAMP PROOFING SEALANT RUBBER BASE, RE: SPEC. 30 TYP. EXT. PRECAST WALL, RE: 2/A9.0.1 2" RIGID INSULATION FLUID APPLIED WP GROUT, RE: STRUCT. TYP. GRADE BEAM, RE: 9/A9.0.1 & STRUCT. PLYWD BACKING DAMP PROOFING PERFORATED UNDERDRAIN PIPE W/ GRAVEL, WRAPPED IN GEO TEXTILE FABRIC 6" MIN. 12" CONC. SLAB, RE: STRUCT. 2" MUD MAT VAPOR RETARDER DRAINAGE BOARD SEALANT RUBBER BASE, RE: SPEC. DRIANAGE BOARD TO INTERACT WITH GRAVEL AND FOLLOW SLOPE OF DRAIN UNDERDRAIN PIPE TO SLOPE @ 1/8" PER FOOT 30 HD SS HD SS SS S SS S S SS S SS SS SS SS SS SS SS SS SS SS S SS SS SS SS SS SS SS HD SS SS SS SS SS J SS SS SS J SS SS SS SS J J J J J J J J J J J F E D C B A 6 7 8 9 10 H G 3 2 3 3 3 1 1 1.3.1 OS OS D D OS OS OS OS OS OS OS OS OS OS OS OS OS 3 OS 3 3 OS D OS J J J J J J J J J J J J J J J J J J OS OS REF. REF. F E D C B A 6 7 8 9 10 H G F3D F3D F3D F3D F3D F3D F3D F3D F3D F3D F3D F3D F3D F3D F3D F3D F3D F3D 4 4 F6 F6 F6 F6 F6 F6 8050 Exterior Signage at Fort Collins Museum of Discovery Page 23 of 24 8050 Exterior Signage at Fort Collins Museum of Discovery Page 24 of 24 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F1 F1 F6 F6 F2 F2 F2 F2 F2 F2 F2 F2 F2 SL4B SL4B SL4C SL4C F2 F2 F2 F2 F2 F2 F6 F6 F2 F3A F3A 3 3 1 1 1 1 1 1 1 F6 F6 2 1 JAN 116 MDF / IT 117 MEN 114 WOMEN 113 CIRC 126B FAMILY LAV 115 CLASSROOM 110 CLASSROOM 109 WORK ROOM 111 STORAGE 112 CORRIDOR 103 MEN 107 WOMEN 108 JAN 106 VEST 105A CAFE 104 GIFT SHOP 102 NA 101 VEST 101A VOLUNTEER WORK 120 STOR 128B ELEV MACH 124 MECH 123 COLLECTION STORAGE 128A ELEC 122 HALL 121 REFERENCE 118 COAT 100C 2 F2 F6 1 F1 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 6 F7 F7 F7 F7 6 6 6 F3D F3D F3D F3D F3D F3D F3D F3D X2 X2 X2 X X2 X2 X2 X2 X2 L1 X L1 L1 L1 T2 T1 T3 T3 T3 T3 F10 F16 F16 F6 F6 F6 F6 7 F5 F5 7 SL4A 5 9 TYP. F3A F3A F3A X2 11 10 F14 F6 F6 F6 F14 F15 F15 F3D F6 F6 F6 F6 3 HLCP-11 (PART) HL1-7 5 5 HL1-5 (PART) HLCP-15 (PART) F6 F6 F6 F6 F6 F6 F6 F6 F10 F10 F10 X2 X2 F6 12 X2 HLCP-9 (PART) F10 F10 F15 F15 F15 F15 F17 2 5 5 4 HL1-5 (PART) F6 F6 12 HL1-5 (PART) F3B UP TO MEZZ. F8, TYP. T3 F6 F6 F6 F6 a b a a a a b b X2 HLCP-11 LL1-3 b LL1-1 X 13 14 13 14 13 14 13 14 14 14 14 14 14 14 13 14 14 F1 F1 F1 HLCP-15 (PART) HLCP-15 (PART) HLCP-15 (PART) HLCP-15 (PART) HLCP-15 (PART) 13 HLCP-15 (PART) LLCP-61,63,65 LLCP-55,57,59 LLCP-49,51,53 LLCP-37,39,41 LLCP-43,45,47 LLCP-31,33,35 LLCP-25,27,29 LLCP-19,21,23 LLCP-13,15,17 LLCP-7,9,11 LLCP-1,3,5 LLCP-67,69,71 EM EM EM EM EM EM EM EM EM EM F3D F3D X2 EM EM EM EM F3A F3A 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 HLCP-1 VIA RELAY 17 F5 1. OCCUPANCY SENSOR SHALL FUNCTION AS MANUAL ON, AUTOMATIC OFF. 2. PROVIDE SWITCH FOR MANUAL OVERRIDE OF LOCAL OCCUPNACY SENSOR. CIRCUIT OCCUPNACY SENSOR TO LINESIDE OF LIGHTING CIRCUIT SERVING ROOM, AHEAD OF WALL SWITCH. 3. PROVIDE LOCAL SLIDE DIMMER SWITCH FOR DIMMING CONTROL OF FIXTURES IN THIS AREA. SWITCH SHALL HAVE A PADDLE TYPE ON-OFF SWITCH WITH VERTICAL SLIDER. DIMMER SWITCH SHALL BE COMPATIBLE WITH FLUORESCENT DIMMING BALLAST. 4. CEILING MOUNTED DUAL TECHNOLOGY OCCUPNACY SENSOR. SENSOR SHALL BE CONNECTED TO LINESIDE OF LIGHTING CIRCUIT SERVING ROOM, AHEAD OF WALL SWITCH. SENSOR SHALL HAVE 1,000 SQUARE FOOT 360°COVERAGE. 5. CONNECT BATTERY BACKUP TO UNSWITCHED LEG OF CIRCUIT. CONNECT TO CIRCUIT HLCP-7. MOUNT 10'-6" A.F.F. 6. (2) LIGHT STRIP FIXTURES LOCATED BEHIND MIRROR, ONE AT THE TOP OF MIRROR AND ONE AT THE BOTTOM. 7. WALL MOUNT FIXTURE 8'-0" ABOVE STAIR IN STAIR WELL. 8. CHAIN HUNG FIXTURES AT 10'-0" A.F.F. 9. MOUNT STEP LIGHT FIXTURE 12" ABOVE STAIR TREAD, TYPICAL. 10. PROVIDE FIXTURE WITH 120V BALLAST AND CONNECT TO ELEVATOR EQUIPMENT ROOM DEDICATED POWER & LIGHTING CIRCUIT LP2-67. 11. SEE ELEVATOR ENLARGED FLOOR PLAN ON DRAWING E6.0 FOR ELEVATOR PIT LIGHT AND CONTROLS. 12. CONNECT TO CIRCUIT HLCP-7. CONNECT EMERGENCY BATTERY PACK TO UNSWITCHED LEG OF CIRCUIT. 13. PROVIDE 277V CIRCUIT FROM HLCP TO THIS POINT FOR CONNECTION TO EXHIBIT SPACE GENERAL LIGHTING CIRCUIT. CIRCUIT SHALL INCLUDE SWITCHED AND UNSWITCHED LEGS, WITH UNSWITCHED LEG TO BE CONNECTED TO BATTERY BACKUP UNITS IN EXHIBIT AREA GENERAL LIGHTING FIXTURES. 14. PROVIDE THREE 120V CIRCUITS, EACH WITH DEDICATED NEUTRAL CONDUCTOR, FROM PANEL LLCP TO THIS POINT. CIRCUITS ARE FOR CONNECTION TO EXHIBIT ACCENT AND DISPLAY LIGHTING FIXTURES. 15. WALL MOUNT EMERGENCY BATTERY BACKUP FIXTURE AS HIGH ON WALL AS POSSIBLE, COORDINATE EXACT LOCATION WITH EXHIBIT FEATURES AND EXHIBIT DESIGNER IN FIELD. CONNECT TO NEAREST LOCAL UNSWITCHED LIGHTING CIRCUIT. KEY NOTES X (THIS SHEET) 1. ALL OCCUPANCY SENSORS SHALL BE DUAL TECHNOLOGY TYPE. 2. OCCUPANCY SENSORS SERVING PRIVATE OFFICES, RESTROOMS AND STORAGE AREAS SHALL FUNCTION BY MANUAL ON, AUTOMATIC OFF CONTROL. 3. VERIFY LOCATIONS OF EXIT SIGNS WITH ARCHITECT AND AUTHORITY HAVING JURISDICTION. 4. CONNECT EMERGENCY BATTERY BACKUP UNITS AND EXIT SIGNS TO UNSWITCHED LEG OF LIGHTING CIRCUITS. 5. EXHIBIT AREA LIGHTING FIXTURES, BOTH GENERAL USE AND ACCENT & DISPLAY LIGHTING; TO BE INDICATED BY SEPARATE PLANS FROM LIGHTING DESIGNER (SHOWN IN LIGHT LINE WEIGHT ON THIS PLAN FOR REFERENCE ONLY). GENERAL USE LINEAR LIGHTING TO INCLUDE EMERGENCY BATTERY BACKUP FOR ONE LAMP EVERY 16 FEET IN GENERAL USE LINEAR LIGHTING SYSTEM ABOVE EGRESS PATHWAYS. ADDITIONAL GENERAL USE LIGHTING IS SHOWN ON THIS SET OF PLANS IN AREA WHERE LIGHTING DESIGNER'S PLANS WILL NOT INCLUDE GENERAL USE LIGHTING FIXTURES. GENERAL NOTES (THIS SHEET) PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 11/25/11 408 MASON COURT FORT COLLINS, CO 80524 1/31/2012 2:26:04 PM D:\My Data\My Revit Projects\MEG-Central_Ft Collins Museum_MEP_2010 - Record_dan.vencill.rvt As indicated FORT COLLINS DISCOVERY MUSEUM 809001.00 MEG JR 08/18/2010 FINAL CONSTRUCTION DOCUMENTS LEVEL 1 LIGHTING PLAN - AREA B E2.3B FORT COLLINS DISCOVERY MUSEUM PJ 1/8" = 1'-0" 1 LEVEL 1 LIGHTING - AREA B d e s i g n m R e High Performance Building Consultants SUITE 3000 80202 3 0 3 . 3 8 2 . 1 9 2 0 w w w . m e g r o u p . c o m Job #: G UP T : 3 0 3 . 3 8 2 . 1 9 3 0 707 17th Sreet, F : DENVER, CO 583.002 8050 Exterior Signage at Fort Collins Museum of Discovery Page 22 of 24 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 36 1. ALL OUTLETS SHOWN REPRESENT INDIVIDUAL DUPLEX RECEPTACLES. EACH PAIR OF OUTLETS IS INSTALLED ON A 10' X 10' GRID AT 16'-0" NOMINALLY, MOUNTED TO BOTTOM OF STRUCTURE. IN EACH PAIR OF OUTLETS SHOWN, ONE IS FOR CONNECTION TO EXHIBIT LIGHTING AND THE OTHER IS FOR CONNECTION TO MISCELLANEOUS OVERHEAD EQUIPMENT (TV'S, PROJECTORS, ETC.). LIGHTING OUTLETS ARE CIRCUITED SEPARATELY FROM EQUIPMENT OUTLETS. CONTRACTOR SHALL PRICE THE OVERHEAD POWER DISTRIBUTION LAYOUT SHOWN AS AN ADD ALTERNATE. 2. PHOTOELECTRIC SMOKE DETECTORS SHOWN THIS SHEET SHALL BE TIED TO THE DOUBLE-INTERLOCK PRE-ACTION SYSTEM SERVING THE ROOM IN WHICH THEY ARE LOCATED. ALL PRE-ACTION SYSTEM COMPONENTS TO BE PROVIDED BY FIRE PROTECTION CONTRACTOR. GENERAL NOTES (THIS SHEET) 1. TIE DOOR HOLDERS TO LOCAL PHOTOELECTRIC SMOKE DETECTIORS. DOORS TO CLOSE UPON DETECTION. 2. REFER TO ELEVATOR DETAIL, SHEET E6.0, FOR FIRE ALARM REQUIREMENTS TO ELEVATOR EQUIPMENT. 3. PROVIDE JUNCTION BOX AT CEILING, TIGHT TO STRUCTURE WITH 120V CIECUIT LM1-5 FOR CONNECTION TO HVAC CONTROL TRANSFORMER(S). KEY NOTES X (THIS SHEET) PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 11/25/11 408 MASON COURT FORT COLLINS, CO 80524 1/31/2012 2:25:48 PM D:\My Data\My Revit Projects\MEG-Central_Ft Collins Museum_MEP_2010 - Record_dan.vencill.rvt As indicated FORT COLLINS DISCOVERY MUSEUM 809001.00 Author Checker 08/18/2010 FINAL CONSTRUCTION DOCUMENTS LEVEL 1 CEILING POWER & SYSTEMS PLAN - AREA B E2.2B FORT COLLINS DISCOVERY MUSEUM Approver d e s i g n m R e High Performance Building Consultants SUITE 3000 80202 3 0 3 . 3 8 2 . 1 9 2 0 w w w . m e g r o u p . c o m Job #: G UP T : 3 0 3 . 3 8 2 . 1 9 3 0 707 17th Sreet, F : DENVER, CO 583.002 1/8" = 1'-0" 1 GALLERY LEVEL CEILING POWER & SYSTEMS - AREA B 8050 Exterior Signage at Fort Collins Museum of Discovery Page 21 of 24 22 2" RIGID INSULATION 12" CONC. SLAB, RE: STRUCT TYP. GRADE BEAM, RE: 9/A9.0.1 & STRUCT. ISOLATION JOINT EXT. PAVING, RE: LANDSCAPE 3" STOREFRONT WINDOW SYSTEM 1/2" GROUT DOWELL, RE: STRUCT. DAMPPROOFING 2" MUD MAT VAPOR RETARDER STOREFRONT WNDW SILL RECEPTOR SHIM W/ BACKER ROD & SEALANT BOTH SIDES 1 1/2" ALUMINUM SILL EXTENSION 339 TYP. EXT. STUCCO WALL SYSTEM, RE: 1 / A9.0.1 TYVEK STRAIGHT FLASHING - EXTEND UP WALL 8" TYP. GRADE BEAM, RE: 9 / A9.0.1 & STRUCT. 12" CONC. SLAB, RE: STRUCT. 2" MUD MAT VAPOR RETARDER DAMP PROOFING (STOP JUST BELOW GRADE) 2" RIGID INSULATION SEALANT RUBBER BASE, RE: SPEC. STUCCO WRAP - EXTEND DN OVER TYVEK STRAIGHT FLASHING WEEP SCREED BACKER ROD & SEALANT MIN. 4" SPRAY FOAM INSULATION 1" TYVEK COMMERCIAL WRAP INSTALL FIRST OVER SHEATHING PRIMER TO BE INSTALLED AT CONCRETE PRIOR TO INSTALLTION OF TYVEK STRAIGHT FLASHING 113 114 540 180 TYP. GRADE BEAM, RE: 9 / A9.0.1 12" CONC. SLAB, RE: STRUCT. 2" MUD MAT VAPOR RETARDER 2" RIGID INSULATION DAMP PROOFING (STOP JUST BELOW GRADE) STOREFRONT WNDW SILL RECEPTOR SHIM W/ BACKER ROD & SEALANT BOTH SIDES MIN. 4" 511 LOBBY FFE 100' - 0" GALLERY FFE 97' - 0" 12" CONC. SLAB, RE: STRUCT. SEALANT RUBBER BASE, RE: SPEC. 43 2" RIGID INSULATION 12" CONC. SLAB, RE: STRUCT TYP. GRADE BEAM, RE: 9/A9.0.1 & STRUCT. ISOLATION JOINT EXT. PAVING, RE: LANDSCAPE 5/8" GYP BD OVER 1 5/8" MTL STUD GROUT DOWELL, RE: STRUCT. DAMPPROOFING 2" MUD MAT VAPOR RETARDER BASEBOARD RADIATION, RE: MECH BACKER ROD & SEALANT BREAK MTL TO MATCH WINDOW SYSTEM - WRAP OVER SHEATHING SEALANT 1/2" REVEAL, RE: SPEC. 3/4" WOOD SILL W/ ALUM GRILLE @ RADIATOR LOCATIONS, RE: MECH MEMBRANE FLASHING - WRAP DN OVER MTL BASE FLASHING 5/8" EXTERIOR GYP SHEATHING STOREFRONT WNDW SILL RECEPTOR SHIM W/ BACKER ROD & SEALANT BOTH SIDES MTL 3 1/2" SPRAY FOAM INSULATION 9 3/8" 2" 1' - 1 3/4" 2" 6" METAL STUDS 16 GUAGE @ 16" W/ CL600 118 STIFF CLIP CL W/ (6) #12 SDST SCREWS AS SHOWN W/ 1/2" EXPANSION ANCHOR 3 1/4" EMBEDMENT 1' - 4 1/4" 103 EXTEND BREAK METAL DOWN PAST TOP OF EXTERIOR SLAB 140 1" 2 3/8" TYP. 1/8" TYP. 3/8" 6" PAINTED WOOD BASE W/ 1/8" ROUTED OPENINGS: 48" LONG SLOTS ALIGN WITH HORIZONTAL GRILLS ON SILL - CENTER ON WINDOW SYSTEM 215 464 30 6" TYP. EXT. PRECAST WALL, RE: 2/A9.0.1 2" RIGID INSULATION DAMP PROOFING GROUT, RE: STRUCT. TYP. GRADE BEAM, RE: 9/A9.0.1 & STRUCT. 12" CONC. SLAB, RE: STRUCT. 2" MUD MAT 4'-0" PERIMTER OF GALLERIES (RE: A2.1): (2) LAYERS OF UNDERSLAB INSULATION/VAPOR BARRIER (THE BARRIER 3/8" + BARRIER X5 1/14") SEALANT RUBBER BASE, RE: SPEC. OVERLAP STANDARD VAPOR BARRIER AND TAPING METHODS PER MANUFACTURERS STANDARD INSTRUCTIONS 30 26 TYP. INT. GALLERY WALL ASSEMBLY W/ PLYWOOD RE: 10.1.3 MEMBRANE FLASHING - EXTEND UP WALL 8" TYP. GRADE BEAM, RE: 2/S4.1 12" CONC. SLAB, RE: STRUCT. 2" MUD MAT VAPOR RETARDER DAMP PROOFING (STOP JUST BELOW GRADE) 2" RIGID INSULATION SEALANT RUBBER BASE, RE: SPEC. WEATHER BARRIER - EXTEND DN OVER STARTER TRAC DRIP EDGE PREFINISHED METAL FLASHING SPRAY FOAM INSULATION LAPPED ONTO STRUCT. SLAB WEEP SCCREED 8" METAL STUDS 3" RIGID INSULATION IN BETWEEN STUDS WIND-LOCK: WSTDE-2 STARTER TRAC DRIP EDGE WEEP HOLES 2" X 8' 15/BX PRECAST BEYOND RE: 2/A9.0.1 1' - 4 1/4" TYP. STUCCO WALL ASSEMBLY SIM. 1/A9.0.1 51 CONCRETE INFILL AT KNEE WALL GRADE BEAM AND KNEE WALL RE: 2/S45.1 100 8 5/8" 3 5/8" STUD 1 5/8" 1 5/8" METAL STUDS 1' - 2 5/8" 124 2" RIGID INSULATION 12" CONC. SLAB, RE: STRUCT TYP. GRADE BEAM, RE: 9/A9.0.1 & STRUCT. ISOLATION JOINT EXT. PAVING, RE: LANDSCAPE DOWELL, RE: STRUCT. DAMPPROOFING 2" MUD MAT VAPOR RETARDER BACKER ROD & SEALANT BREAK MTL TO MATCH METAL PANEL SYSTEM - WRAP OVER SHEATHING SEALANT 1/2" REVEAL, RE: SPEC. 3/4" WOOD SILL MEMBRANE FLASHING - WRAP DN OVER MTL BASE FLASHING 5/8" EXTERIOR GYP SHEATHING STOREFRONT WNDW SILL RECEPTOR SHIM W/ BACKER ROD & SEALANT BOTH SIDES MTL 3 1/2" SPRAY FOAM INSULATION MIN. R-25 2' - 6" 6" METAL STUDS RUBBER BASE (RB-1) SLOPED TO DRAIN 1' - 3 5/8" TYP. PRECASE WALL ASSEMBLY W/O PLYWOOD BACKING RE: 2/A9.0.1 RADIATOR SURFACE MOUNTED @ ROOMS 139 AND 140 3/4" PLYWOOD BLOCKING SLOPED PLYWOOD BLOCKING CL600 118 STIFF CLIP CL W/ (6) #12 SDST SCREWS AS SHOWN ANCHORED TO ACCESS FLOORING WHEN USING 6" STUD 1' - 3 5/8" TYP. 3" 3" 103 2" RIGID INSULATION 12" CONC. SLAB, RE: STRUCT TYP. GRADE BEAM, RE: 9/A9.0.1 & STRUCT. ISOLATION JOINT EXT. PAVING, RE: LANDSCAPE DOWELL, RE: STRUCT. DAMPPROOFING 2" MUD MAT VAPOR RETARDER BASEBOARD RADIATION W/ ENCLOSURE, RE: MECH RECESSED INTO KNEE WALL BACKER ROD & SEALANT BREAK MTL TO MATCH METAL PANEL SYSTEM - WRAP OVER SHEATHING SEALANT 1/2" REVEAL, RE: SPEC. 3/4" WOOD SILL MEMBRANE FLASHING - WRAP DN OVER MTL BASE FLASHING 5/8" EXTERIOR GYP SHEATHING STOREFRONT WNDW SILL RECEPTOR SHIM W/ BACKER ROD & SEALANT BOTH SIDES MTL 3 1/2" SPRAY FOAM INSULATION 2' - 6" 2" 2' - 0" 6" 2" RUBBER BASE (RB-1) 4" SLOPED BREAK METAL SILL 1' - 3 5/8" TYP. PRECASE WALL ASSEMBLY W/O PLYWOOD BACKING RE: 2/A9.0.1 KNEE WALL ON EITHER SIDE OF RADIATOR W/ 4" OF SPACE BETWEEN RADIATOR AND WALL ON EACH SIDE RE: PLANS 3/4" PLYWOOD BLOCKING SLOPED PLYWOOD BLOCKING CL600 118 STIFF CLIP CL W/ (6) #12 SDST SCREWS AS SHOWN ANCHORED TO ACCESS FLOORING WHEN USING 6" STUD 3" 3" 9 1/2" TYP. 1' - 3 5/8" 103 2" RIGID INSULATION 12" CONC. SLAB, RE: STRUCT TYP. GRADE BEAM, RE: 9/A9.0.1 & STRUCT. ISOLATION JOINT EXT. PAVING, RE: LANDSCAPE 5/8" GYP BD OVER 1 5/8" MTL STUD GROUT DOWELL, RE: STRUCT. DAMPPROOFING 2" MUD MAT VAPOR RETARDER BASEBOARD RADIATION, RE: MECH ALUM GRILLE @ RADIATOR LOCATIONS, RE: MECH BACKER ROD & SEALANT BREAK MTL TO MATCH METAL PANEL SYSTEM - WRAP OVER SHEATHING SEALANT 1/2" REVEAL, RE: SPEC. 3/4" WOOD SILL W/ ALUM GRILLE @ RADIATOR LOCATIONS, RE: MECH MEMBRANE FLASHING - WRAP DN OVER MTL BASE FLASHING 5/8" EXTERIOR GYP SHEATHING STOREFRONT WNDW SILL RECEPTOR SHIM W/ BACKER ROD & SEALANT BOTH SIDES MTL 3 1/2" SPRAY FOAM INSULATION 9 3/8" 2" 1' - 1 3/4" 2" SLOPED BREAK METAL SILL 3" TYP. 3/4" PLYWOOD BLOCKING SLOPED PLYWOOD BLOCKING 6" METAL STUDS 16 GUAGE @ 16" W/ CL600 118 STIFF CLIP CL W/ (6) #12 SDST SCREWS AS SHOWN W/ 1/2" EXPANSION ANCHOR 3 1/4" EMBEDMENT 103 1'-4 1/4" TYP. CONC GRADE BEAM RE: STRUCTURAL STUCCO EXTERIOR WALL ASSEMBLY RE: 1/A9.01 FOR DETAILS GALV WEEP SCREED CONC SLAB RE: STRUCTURAL PEEL & STICK MEMBRANE FLASHING BEHIND METAL FLASHING 22 GA PREFINISHED METAL FLASHING- EXTEND UP ABOVE T.O.SLAB 8 IN AND DOWN TO T.O. FOUNDATION - SLOPE @ FLOOR SLAB WEATHER RESISTIVE BARRIER LAP OVER FLASHING SEALANT BEAD 1/2" FIBER MATERIAL CONCRETE PAD, RE: CIVIL 8" TYP. 143 2" 180 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 1/31/2012 6:24:21 PM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt As indicated FORT COLLINS DISCOVERY MUSEUM 809001.00 KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS FOUNDATION DETAILS A9.1.1 FORT COLLINS DISCOVERY MUSEUM DS 1 FOUNDATION 1 1/2" = 1'-0" @ LOW GRADE 2 FOUNDATION 1 1/2" = 1'-0" @ FLUSH GRADE 3 FOUNDATION 1 1/2" = 1'-0" @ HIGH GRADE 4 WINDOW 1 1/2" = 1'-0" @ FLUSH GRADE 5 FOUNDATION 1 1/2" = 1'-0" @ STUCCO WALL 6 WINDOW 1 1/2" = 1'-0" SILL @ STUCCO WALL 7 CORRIDOR 1 1/2" = 1'-0" WALL @ SLAB EDGE 8 WINDOW 1 1/2" = 1'-0" @ CURB W/ DEEP SILL 9 1 1/2" = 1'-0" TYP. UNDERSLAB INSULATION/VAPOR BARRIER @ GALLERIES PERIMETER 10 FOUNDATION 1 1/2" = 1'-0" @ LOW INSET STUCCO WALL 12 WINDOW 1 1/2" = 1'-0" @ CURB W/ DEEP SILL NO RADIATOR (ADMIN) 13 1 1/2" = 1'-0" WINDOW @ CURB W/ DEEP SILL AND RECESSED RADIATOR 11 WINDOW 1 1/2" = 1'-0" @ CURD W/ DEEP SILL (NATURAL AREAS) 14 STUCCO 3" = 1'-0" @ EXT. SLAB 8050 Exterior Signage at Fort Collins Museum of Discovery Page 20 of 24 3/4" 3/4" 135.00° TYP. PRECAST WALL ASSEMBLY, RE: 2A/A9.01 WORK POINT DOUBLE BACKER ROD & SEALANT 1 1/2" 1/2" REVEAL DBL SEALANT JOINT WEEP @ VERT. JOINT 6" ABOVE GRADE 30 30 7" 3 1/2" 7/8" 3 5/8" 1 1/4" 46 373 1 1/2" METAL PANEL 2" Z-FURRING @ 48" O.C. VERT. 2" RIGID INSULATION (R-10.0 MIN) WEATHER BARRIER 5/8" EXT. GYP. SHEATHING 6" METAL STUD W/ SPRAY FOAM INSUL. (R-15.0 MIN) 5/8" GYP. BD. 1 1/2" METAL PANEL 2" RIGID INSULATION (R-10.0 MIN) WEATHER BARRIER 5/8" GYP. BD. 6" METAL STUD W/ SPRAY FOAM INSUL. (R-15.0 MIN) 5/8" EXT. GYP. SHEATHING 11" 1" 1 1/2" 2" 7 1/4" 351 TPO ROOF MEMBRANE OVER BONDING ADHESIVE RIGID INSULATION (R-35.0 MIN.) 1 1/2" METAL DECK ON STR. BAR JOINTS OR STR. BEAM, RE: STRUCT'L AIR BARRIER 1/2" SUBSTRATE BOARD 1/4" SUBSTRATE BOARD 25 25 STANDING SEAM MTL ROOFING PANEL HIGH TEMPERATURE UNDERLAYMENT METAL DECK STEEL STRUCTURE, RE: STRUCTURAL SPRAY FOAM INSULATION (R-22.5 MIN) 2 5/8" NAILBASE (2" RIGID INSUL. ADHERED PAD & 5/8" OSB., R-12.5 MIN) MOUNTED SNOW CLIP - WHERE OCCURS DOUBLE BACKER ROD & SEALANT 3/8" 3/8" TYP. PRECAST WALL ASSEMBLY, RE: 2A/A9.01 3/4" 135.00° 3/4" WORK POINT 30 223 DOUBLE BACKER ROD & SEALANT TYP. PRECAST WALL ASSEMBLY, RE: 2A/A9.01 135.00° 3/8" 3/8" WORK POINT 3/4" 3/4" 30 4" CONC TOPPING SLAB 2" RIGID INSULATION (R-12.0 MIN) COMPOSITE DRAINAGE LAYERS ABOVE AND BELOW THE 2" RIGID INSUALTION FLUID APPLIED WATERPROOF MEMBRANE AND PROTECTION COURSE CONC SLAB ON METAL DECK, RE: STRUCT STEEL STRUCTURE, RE: STRUCT BATT INSULATION (R-23.0 MIN) 6 3/8" +/- 45 334 2" RIGID INSULATION (R-10.0 MIN.) DAMPPROOFING CIP CONCRETE 1" 1" PANEL JOINT FULL OF SEALANT PRECAST CONC PANEL BEYOND (PAINTED) CONT BEAD OF SEALANT TERMINATION BAR FASTENERS @ 12" O.C. (DO NOT FASTEN TERMINATION BAR ON THIS SIDE OF JOINT) TPO MEMBRANE BELOW TERMINATION BAR H TYP. PRECAST ASSEMBLY RE: 2/A9.0.1 SIM. TYP. STUCCO ASSEMBLY RE:1A9.0.1 TYP. 3" 1/2" CAULK AND BACKER ROD JOINT 3 3/8" 9" 1' - 1 1/4" 3 1/2" FINISH PRECAST MIX SANDBLAST FINISH 27 1' - 4 1/4" 47 1' - 0" PANEL JOINT ELEVATION PANEL JOINT 10' - 0" 1' - 0" 8' - 0" RE: ELEVATIONS 4" SIZE VARIES 2''0", 3'-0" OR 4'-0" 13 A9.0.1 GREEN SCREEN 2" TYP. PANEL TRIM 5105 6" + - 5" + - 5132 MOUNTING CLIP EXTEND TO FULL 2 1/4" RE 13/A9.0.1 EQ. EQ. PRECAST WALL 47 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 1/31/2012 6:24:08 PM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt As indicated FORT COLLINS DISCOVERY MUSEUM 809001.00 KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS EXTERIOR TYPICAL ASSEMBLY DETAILS A9.0.1 FORT COLLINS DISCOVERY MUSEUM DS 1 TYP. 3" = 1'-0" STUCCO WALL ASSEMBLY 2 TYPICAL 3" = 1'-0" PRECAST WALL ASSEMBLY 5 TYP. 3" = 1'-0" METAL PANEL WALL ASSEMBLY 6 TYPICAL 3" = 1'-0" TPO ROOF ASSEMBLY 7 TYP 3" = 1'-0" METAL ROOF ASSEMBLY 3 3" = 1'-0" TYP PRECAST WALL JOINT - OBTUSE ANGLE 4 3" = 1'-0" TYP PRECAST WALL JOINT -REFLEX ANGLE B - PLAN A - SECTION B - PLAN A - SECTION B - PLAN A - SECTION 8 TYP 3" = 1'-0" ROOF TERRACE ASSEMBLY 9 TYP 3" = 1'-0" GRADE BEAM 11 3" = 1'-0" TERMINATION AT PRECAST PANEL JOINT 12 PRECAST/3" = 1'-0" STUCCO WALL TRANSITION 13 GREEN 3" = 1'-0" SCREEN DETAIL 10 GREEN 3/4" = 1'-0" SCREEN TRELLIS NOTE: THE TRELLIS SYSTEM WAS VALUE ENGINEERED FROM THE PROJECT AND WAS NOT INSTALLED BY HENSEL PHELPS AS DIRECTED BY THE OWNER. DETAILS HAVE BEEN LEFT ON THE CONTRACT DRAWINGS FOR REFERENCE IF IN THE FUTURE THE TRELLIS IS ADDED BACK INTO THE PROJECT BY THE OWNEER. 52 NOTE: THE TRELLIS SYSTEM WAS VALUE ENGINEERED FROM THE PROJECT AND WAS NOT INSTALLED BY HENSEL PHELPS AS DIRECTED BY THE OWNER. DETAILS HAVE BEEN LEFT ON THE CONTRACT DRAWINGS FOR REFERENCE IF IN THE FUTURE THE TRELLIS IS ADDED BACK INTO THE PROJECT BY THE OWNEER. 8050 Exterior Signage at Fort Collins Museum of Discovery Page 19 of 24 C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt 1/4" = 1'-0" FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL/KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS ENLARGED ELEVATION - PARTIAL EAST ELEV A5.2.3 FORT COLLINS DISCOVERY MUSEUM DS 2 PARTIAL 1/4" = 1'-0" EAST ELEVATION 1 8050 Exterior Signage at Fort Collins Museum of Discovery Page 18 of 24 FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL/KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS ENLARGED ELEVATION - PARTIAL SOUTH ELEV A5.2.2 FORT COLLINS DISCOVERY MUSEUM DS 1 PARTIAL 1/4" = 1'-0" SOUTH ELEV 2 8050 Exterior Signage at Fort Collins Museum of Discovery Page 17 of 24 FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL/KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS ENLARGED ELEVATIONS - PARTIAL SOUTH ELEV A5.2.1 FORT COLLINS DISCOVERY MUSEUM DS 1 PARTIAL 1/4" = 1'-0" SOUTH ELEV 1 8050 Exterior Signage at Fort Collins Museum of Discovery Page 16 of 24 119' - 7" 2 A5.1.2 A9.3.3 3 A9.3.3 3 SIM. 125 149 2 RFI 252.1 A3 A5.1.2 4 191 PANEL MAP 10 3/4" 2' - 0" 4' - 0" EQ. EQ. EQ. 1" 11" 1" EQ. 6" ANNUNCIATOR PANEL METLA PANEL WALL ASSEMBLY KAWNEER ENCORE GLAZING SYSTEM MAP 2' - 0" 6 5/8" 1' - 6" HC 4 1/2" HC EQ. 4 1/2" EQ. EQ. EQ. 191 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 1/31/2012 6:15:48 PM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt As indicated FORT COLLINS DISCOVERY MUSEUM 809001.00 Author Checker 08/18/10 FINAL CONSTRUCTION DOCUMENTS WALL SECTIONS A5.1.2 FORT COLLINS DISCOVERY MUSEUM Approver 1 WALL 3/8" = 1'-0" SECTION @ VESTIBULE 126A 2 SECTION 3/8" = 1'-0" @ LOBBY VESTIBULE 101A NORTH/SOUTH 3 SECTION 3/8" = 1'-0" @ LOBBY VESTIBULE 101A EAST/WEST 4 ANNUNCIATOR 1" = 1'-0" PANEL IN VESTIBULE 8050 Exterior Signage at Fort Collins Museum of Discovery Page 15 of 24 LOWER ROOF 116' - 0" GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" T.O. PARAPET 120' - 0" A9.2.1 1 METAL PRECAST CAP OVERFRAME MEZZANINE 119' - 7" A9.1.1 8 TYP. PRECAST WALL ASSEMBLY RE: 1/A9.0.1 30 30 LOBBY FFE 100' - 0" LOWER ROOF 116' - 0" GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" T.O. PARAPET 120' - 0" A9.3.1 2 A9.2.1 7 A9.1.1 6 OVERFRAME MEZZANINE 119' - 7" 511 LOBBY FFE 100' - 0" LOWER ROOF 116' - 0" GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" T.O. PARAPET 120' - 0" A9.2.1 7 A9.1.1 5 OVERFRAME MEZZANINE 119' - 7" LOBBY FFE 100' - 0" LOWER ROOF 116' - 0" UPPER ROOF 144' - 0" GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" A9.2.1 3 A9.3.1 4 OVERFRAME MEZZANINE 119' - 7" T.O. UPPER PARAPET 147' - 7" A9.1.1 8 A9.2.1 9 A9.2.1 9 SIM. SIM. 205 186 508 464 LOBBY FFE 100' - 0" LOWER ROOF 116' - 0" GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" T.O. PARAPET 120' - 0" TYP. PRECAST WALL ASSEMBLY RE: 2/A9.0.1. TYP. PRECAST WALL ASSEMBLY RE: 2/A9.0.1. 30 30 GALLERY FFE 97' - 0" T.O. PARAPET 120' - 0" A9.2.1 7 A9.2.2 11 A9.2.2 12 H A9.1.1 10 51 1 5/8" F.V. 13' - 6" 121 8 5/8" 1' - 2 5/8" 153 181 49 21 27 306 LOBBY FFE 100' - 0" LOWER ROOF 116' - 0" GALLERY FFE 97' - 0" T.O. PARAPET 120' - 0" A9.2.1 7 21 A9.3.1 12 A9.4.1 15 A9.4.1 15 49 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 1/31/2012 6:15:42 PM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt 3/8" = 1'-0" FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL/KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS WALL SECTIONS A5.1.1 FORT COLLINS DISCOVERY MUSEUM DS 1 3/8" = 1'-0" WALL SECTION - PRECAST @ EAST ELEV 2 3/8" = 1'-0" WALL SECTION - PRECAST @ SOUTH ELEV 3 3/8" = 1'-0" WALL SECTION - PRECAST @ SOUTH ELEV W/ GLAZING 4 3/8" = 1'-0" WALL SECTION - STUCCO @ CAFE GLAZING 5 3/8" = 1'-0" WALL SECTION - STUCCO @ CAFE 6 3/8" = 1'-0" WALL SECTION - METAL PANEL 7 3/8" = 1'-0" WALL SECTION - PRECAST @ WEST ELEV 8 3/8" = 1'-0" WALL SECTION @ STUCCO INSET 9 3/8" = 1'-0" WALL SECTION @ NORTH STUCCO WALL 8050 Exterior Signage at Fort Collins Museum of Discovery Page 14 of 24 8050 Exterior Signage at Fort Collins Museum of Discovery Page 13 of 24 COLLECTION STORAGE 128A STOR 128B NA 101 DOME M02 LOBBY 100 113' - 0" 110' - 0" 111' - 6" A9.2.1 5 A9.2.1 6 T.O. UPPER PARAPET 147' - 7" 535 623 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 2/1/2012 9:15:05 AM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt 1/8" = 1'-0" FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL/KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS BUIDLING SECTIONS A4.2.1 FORT COLLINS DISCOVERY MUSEUM DS 2 SECTION 1/8" = 1'-0" -EAST/WEST 1 SECTION 1/8" = 1'-0" - NORTH/SOUTH 8050 Exterior Signage at Fort Collins Museum of Discovery Page 12 of 24 STRUCTURAL MEZZANINE 114' - 7" 1 A4.2.1 METAL PANEL COLORED PRECAST STUCCO STUCCO CONTROL JOINTS, TYP. PARTIAL ELEVATION - 4 / A4.1.3 AHU BEYOND T.O. PARAPET 120' - 0" 10" HIGH SS ADDRESS LETTERS ROOF BEYOND A1 A2 A1 B7 B8 A5 E1 D1 C1 2 A5.1.1 3 A5.1.1 METAL COPING S3 E2 S4 S5 26' - 0" GLAZING T.O. UPPER PARAPET 147' - 7" 1 A9.2.3 H 9 A5.1.1 47 5" 47 47 207 207 7 A10.1.7 356 140 463 261 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 2/1/2012 9:08:03 AM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt 1/8" = 1'-0" FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL/KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS ELEVATIONS - SOUTH & WEST A4.1.2 FORT COLLINS DISCOVERY MUSEUM DS 1 WEST 1/8" = 1'-0" ELEVATION 2 SOUTH 1/8" = 1'-0" ELEVATION 8050 Exterior Signage at Fort Collins Museum of Discovery Page 11 of 24 100' - 0" UPPER ROOF 144' - 0" 10 9 8 7 6 5 4 3 2 GALLERY FFE 97' - 0" STRUCTURAL MEZZANINE 114' - 7" 1 121' - 7 1/4" COLORED PRECAST GLAZING METAL PANEL PARTIAL ELEVATION - 2 / A4.1.3 SIGNAGE PANEL A5.2.3 2 ROOF BEYOND T.O. PARAPET 120' - 0" A7 A2 A3 A1 B1 B2 B3 B4 B5 B6 D2 C2 F2 1' - 0" 1 A5.1.1 HORIZONTAL REVEAL ROOF @ DOCK RE: 8:A9.2.1 8 A9.2.1 B9 29' - 0" 2 A4.2.1 Sim GAS METER METAL COPING STUCCO 6 A6.2.1 T.O. UPPER PARAPET 147' - 7" 8 A5.1.1 47 47 47 STUCCO REVEALS - MATCH PRECAST REVEAL ELEVATIONS (ALL THREE SIDES OF INSET) 96 159 10 A9.3.3 207 261 354 140 369 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 2/1/2012 9:04:49 AM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt 1/8" = 1'-0" FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL/KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS ELEVATIONS - NORTH & EAST A4.1.1 FORT COLLINS DISCOVERY MUSEUM DS 1 NORTH 1/8" = 1'-0" ELEVATION 2 EAST 1/8" = 1'-0" ELEVATION 8050 Exterior Signage at Fort Collins Museum of Discovery Page 10 of 24 110 CLASSROOM 109 VEST 105A ELEV MACH 124 OPEN TO STRUCT. OPEN TO STRUCT. GYP SOFFIT @ OPERABLE PARTITION OVERHEAD DOOR TRACK ACT 10' - 0" AFF GYP BD 9' - 0" AFF ACT-1 11' - 9" A.F.F. GYP BD 9' - 0" AFF GYP BD 9' - 0" AFF OPEN TO STRUCTURE 6 A5.1.1 1 A5.2.9 2 A5.2.9 MATCH LINE OPEN TO STRUCTURE STOR 128B COAT 100C COVE LIGHT GYP-1 10' - 6" AFF SPRINKLER HEADS PER ICC ESR-2397 8 A9.5.2 MECH 123 COLLECTION STORAGE 128 GYP-1 12' - 0" A.F.F. GYP-1 11' - 6" A.F.F. GYP-1 SOFFIT 10' - 0" A.F.F. ACT-1 10' - 4" A.F.F. OPEN TO ABOVE OPEN TO ABOVE EQ EQ EQ OPEN TO ABOVE GYP-1 12' - 0" A.F.F. WD-1 4' - 2" 4' - 0" GLASS 12' - 0" A.F.F. 108' - 4" GYP-1 9' - 0" AFF GYP-1 9' - 0" A.F.F. 19' - 8 1/2" ACT-1 9' - 0" A.F.F. ACT 10' - 0" AFF ACT 9' - 0" AFF ACT 10' - 0" AFF GYP BD 9' - 0" AFF GYP BD 9' - 0" AFF GYP BD 9' - 0" AFF GYP BD 9' - 0" AFF ACT 9' - 0" AFF GYP-1 12' - 0" A.F.F. 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" GYP BD 8' - 2.5" A.F.F. GYP-1 SOFFIT 8' - 2.5" A.F.F. ACT 10' - 0" AFF 6' - 5 1/2" 3 7/8" 2" 6' - 6" 14' - 3 1/2" GYP BD 8' - 2" AFF GYP SOFFIT 8' - 2" A.F.F. GYP SOFFIT 8' - 2" A.F.F. GYP BD 8' - 4" AFF GYP BD 8' - 4" AFF 6 A6.2.1 9 A9.3.1 GYP BD 9' - 0" AFF NOTE:CENTRAL CEILING AREA TO INCLUDE ACOUSTICAL PLASTER SYSTEM 8 A5.1.1 1 A9.2.3 GYP BD 9'-0" A.F.F. 6 GYP-1 8' - 6" AFF 7 H 4' - 0" 16' - 0" 14" DIA SOLATUBE 290 DS SERIES 37 35 2 A5.1.2 3 A5.1.2 Sim 125 4 A9.2.3 4 A9.2.3 SIM. GYP-1 12' - 0" A.F.F. 30' - 0 5/8" 9' - 7 1/8" 19' - 6 7/8" 6 A9.2.3 A9.2.3 5 10 A9.3.3 1' - 9 7/8" 8 1/2" ACCESS PANEL 206 206 7 A10.1.7 294 565 153 371 486 160 569 583 145 396 455 149 186 532 205 187 521 487 1. REFLECTED CEILING PLANS INDICATE LOCATION OF CEILINGS, LIGHT FIXTURES, DIFFUSERS, AND SIMILAR ITEMS. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION ON ELECTRICAL, HVAC, SPRINKLER AND LIFE SAFETY DEVICES. IN THE EVENT OF DISCREPANCIES BETWEEN REFLECTED CEILING PLANS AND THE ENGINEERS' PLANS, IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING BEFORE ORDERING MATERIALS OR PROCEEDING WITH WORK. 2. COORDINATE ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS, ETC. NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED. 3. ANY ACCESS PANELS NOT SHOWN ON THE REFLECTED CEILING PLAN BUT REQUIRED BY PLUMBING, MECHANICAL, OR ELECTRICAL SYSTEMS SHALL BE REVIEWED WITH ARCHITECT FOR LOCATION. 4. CONTRACTOR TO COORDINATE LOCATION OF FIRE SPRINKLER HEADS. 5. LIGHT FIXTURES, EXIT SIGNS, SPRINKLER HEADS & OTHER CEILING ELEMENTS SHALL BE LOCATED IN CENTER OF INDIVIDUAL CEILING TILE UNLESS OTHERWISE NOTED. 6. CENTER ACOUSTICAL CEILING GRID WITHIN THE ROOM UNLESS OTHERWISE NOTED. 7. CEILINGS ARE 10'-0" TO THE BOTTOM OF ACOUSTICAL CEILING TILE FROM THE TOP OF SLAB UNLESS OTHERWISE NOTED. 8. GYPSUM BOARD SOFFITS AND CEILINGS ARE TO BE PAINTED P-1 UNLESS OTHERWISE NOTED. 9. PAINT ALL EXPOSED CEILING STRUCTURE & DUCTWORK P_____ UNLESS OTHERWISE NOTED. 10. DIMENSIONS OF SPECIALTY LIGHT FIXTURES ARE TO CENTER OF FIXTURE UNLESS OTHERWISE NOTED. REFLECTED CEILING PLAN NOTES REFLECTED CEILING LEGEND ACT 1 GYP. BD HEIGHT ABOVE FINISHED FLOOR PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 2/1/2012 2:18:17 PM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt As indicated FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL/KG PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS LEVEL ONE RCP - AREA B A3.1b FORT COLLINS DISCOVERY MUSEUM DS 1 LEVEL 1/8" = 1'-0" 1 REFLECTED CEILING PLAN - AREA B 0' 4' 8' 16' 32' 8050 Exterior Signage at Fort Collins Museum of Discovery Page 9 of 24 DIGITAL DOME M02 88 2 15 AREA OLF OCC EXITS 1,286 SF UPPER LOBBY M01 86 2 30 OPEN TO BELOW A-3 A-1 63 63 41 41 126 NA 623 A-3 S-1 B S-1 B F E D C B A 2 3 4 5 6 7 8 9 10 G 1 H AREA OLF OCC EXITS 16,696 SF GALLERY 126 557 3 30 AREA OLF OCC EXITS 3,018 SF CLASSROOMS 107-111 151 2 20 AREA OLF OCC EXITS 692 SF UPPER GALLERY 103A 23 1 30 AREA OLF OCC EXITS 955 SF GIFT SHOP 102 29 1 30 AREA OLF OCC EXITS 3,016 SF LOBBY 100-101 207 3 15 AREA OLF OCC EXITS 1,714 SF REFERENCE 118 33 1 50 AREA OLF OCC EXITS 482 SF MECH 123 51 100 AREA OLF OCC EXITS 218 SF ELEC 122 31 100 AREA OLF OCC EXITS 4,361 SF COLLECTION STORAGE 128 15 1 300 AREA OLF OCC EXITS 782 SF SHOP 132 81 100 AREA OLF OCC EXITS 274 SF STAGING 133 31 100 AREA OLF OCC EXITS 249 SF RECIEVING 134 31 100 AREA OLF OCC EXITS 2,456 SF ADMINISTRATION 135-142 25 1 100 AREA OLF OCC EXITS 5,109 SF TRAVELING EXHIBIT 127 139 2 30 AREA OLF OCC EXITS 385 SF ARTIFACT PROCESSING 131 41 100 A-3 A-3 B F-1 B B S-1 BB B A-3 A-3 A-3 AREA OLF OCC EXITS 489 SF CAFE 104 17 1 30 A-3 A-3 38 38 38 38 2 250 23 17 149 29 63 359 150 35 209 1 208 209 69 70 25 33 8 4 5 3 90 5 22 19 209 250 299 626 35 178 12" Concrete Slab 539 12" Concrete Slab 342 343 298 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 1805 29th Street Suite 2054 Boulder, Colorado 80301 phone 303.449.8900 RECORD DRAWINGS 02/02/12 408 MASON COURT, FORT COLLINS, CO 80524 1/31/2012 5:36:50 PM C:\Revit Local Files\Revit 2010\809001 Discovery\Revit boulder local\809001-FT COLLINS MUSEUM-jlevy local.rvt As indicated FORT COLLINS DISCOVERY MUSEUM 809001.00 JPL PS/DS 08/18/10 FINAL CONSTRUCTION DOCUMENTS CODE PLAN AND ANALYSIS A0.01 FORT COLLINS DISCOVERY MUSEUM DS AREA OCCUPANCY LOAD CALCULATION SUMMARY Number Name Area Occupancy Group Occupancy Two Means of Egress Compare Table 1004.1.1 - Use Description OLF Occ Load Req'd Exits Level Exit Width-Calc 100-101 LOBBY 3,016 SF A-3 Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area 15 202 2 49 LOBBY FFE 102 GIFT SHOP 955 SF M Mercantile - Basements and Grade Floor areas 30 32 1 49 LOBBY FFE 103A UPPER GALLERY 692 SF A-3 Assembly Areas, Exhibit Gallery and Museum - Net Area 30 24 1 49 LOBBY FFE 104 CAFE 489 SF A-3 Assembly Areas, Exhibit Gallery and Museum - Net Area 30 17 1 49 3 3/8" LOBBY FFE 107-111 CLASSROOMS 3,018 SF A-3 Assembly Areas, Exhibit Gallery and Museum - Net Area 30 101 2 49 LOBBY FFE 118 REFERENCE 1,714 SF B Business Areas 100 18 1 49 LOBBY FFE 122 ELEC 218 SF S-1 Business Areas 100 3 1 49 5/8" LOBBY FFE 123 MECH 482 SF S-1 Business Areas 100 5 1 49 LOBBY FFE 124 ELEV. MECH. 58 SF S-1 Accessory storage areas, mechanical equipment room 300 1 1 49 1/4" LOBBY FFE 126 GALLERY 16,696 SF A-3 Assembly Areas, Exhibit Gallery and Museum - Net Area 30 557 3 49 LOBBY FFE 127 TRAVELING EXHIBIT 5,109 SF A-3 Assembly Areas, Exhibit Gallery and Museum - Net Area 30 171 2 49 LOBBY FFE 128 COLLECTION STORAGE 4,361 SF S-1 Accessory storage areas, mechanical equipment room 300 15 1 49 LOBBY FFE 131 ARTIFACT PROCESSING 385 SF B Business Areas 100 4 1 49 LOBBY FFE 132 SHOP 782 SF F-1 Industrial areas 100 8 1 49 LOBBY FFE 133 STAGING 274 SF B Business Areas 100 3 1 49 LOBBY FFE 134 RECIEVING 249 SF B Business Areas 100 3 1 49 LOBBY FFE 135-142 ADMINISTRATION 2,456 SF B Business Areas 100 25 1 49 LOBBY FFE LOBBY FFE 40,953 SF 1189 M01 UPPER LOBBY 1,286 SF A-3 Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area 15 86 2 49 STRUCTURAL MEZZANINE M02 DIGITAL DOME 1,211 SF A-1 Assembly with fixed seats w dividing arms, 1 seat/24" (see Section 1004.7) 13.375 91 2 49 1' - 5 1/2" STRUCTURAL MEZZANINE STRUCTURAL MEZZANINE 2,497 SF 177 301 CONFERENCE 617 SF A-3 Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area 15 42 1 49 UPPER ROOF 302 ROOF DECK 2,861 SF A-3 Assembly Areas, Exhibit Gallery and Museum - Net Area 30 96 2 49 UPPER ROOF UPPER ROOF 3,478 SF 138 Grand total 46,928 SF 1504 3 UPPER 3/32" = 1'-0" ROOF CODE REVIEW 2 MEZZANINE 3/32" = 1'-0" CODE REVIEW . NA . * * OCCUPANCY LOAD IS DERIVED FROM THE NUMBER OF SEATS IN THE DIGITAL DOME. 202 4 OCCUPANCY 1/32" = 1'-0" KEY 8050 Exterior Signage at Fort Collins Museum of Discovery Page 8 of 24