HomeMy WebLinkAboutBid Tally -8110 TRANSFORMERS 3-PHASE PAD-MOUNTED 150, 500 & 750 KVA3 Phase Padmounted Transformer Bid Evaluation #Units 5 %fmr Type 3P Pad Bid#: silo Size 500 kVA SeeondaryV 2771480 Date: May 27,2015 NL Loss Cost S 3.90 Stock # T300051 FL Loss Cost $ 2.30 Specified Impedance % 3.04 (See Impedance Requirements Table in Specification) Includes Winding's Stray Losses Losses a Losses associated Base Bid Rank Based on Rank Based on Base Bid Guar No Guar Total Associated with Audliary Wmdag s with Ausaary Impedance Extended Cost NL Loss - NL FL Lou - FL Bid (1 is best Evaluated Nd (1 Supplier Manufacturer f / Each DeWyks Load Low Guar Fus Load Low Impedance Meet Boom? Escalation Load Lou Devices (Yea / No) Stray Losses Devices Variance Evaluated Bid (Total S) Lou Cold Lou Cast choice) is best choice) Border Stales Howard Industries S 10,459.79 B-10wks ARO 902 3753 3.10 NO No 4655 Yes 163.8 No 1,97% $ 22,609A9 $ 52,298.95 $ 3,517.80 $ 8,631.90 2 - Graybar CG Power Sys $ 12,599.00 10-12 Weeks 905 2673 2.96 No Is 3578 - 0 0 -2.63% $ 22,276.40 $ 62,995.00 $ 3,529.50 $ 6,147.90 7 Irby Utilities Utilities Cooper Power $ 11,244.55 B-10 weeks 970 2941 3.04 Yes is not 3911 Yes 248 0 0,00% $ 21,791.85 $ 56,222.75 $ 3,783.00 $ 6,764.30 4 3 Wesco ASS $ 10,890.00 7-9 Weeks 9% 2668 3.02 Yes Is 3664 Yes 360 0 -0.66% $ 20,910.80 $ 54,450.00 S 3,884.40 S 6,136.40 3 2 Western United CG POWER $ 12,357.00 10-12 Weeks 905 2673 2.98 No Is 3578 - 0 0 -2.63% S 22,034.40 $ 61,785.00 S 3,529.50 $ 6,147.90 6 - Westem United Howard Industries $ 10,368.00 B-10wks ARO 1015 2694 3.00 No No 3709 yes 212.1 No -1.32% $ 20,522.70 $ 51,840.00 $ 3,958.50 3 6,196.20 1 - Imy Cooper - DOE 2016S 11.428.50 B-10 weeks 903 3007 3.05 Yes is not 3910 Yes 253 0 0,33% 321,856.30 S 57,142.50 $ 3,521.70 $ 6,916.10 5 4 0 -100.00% Notes: 1, BSE's bid for Howard units states it does not meet our specification, however they do not include any explanation of this discrepancy in their documentation. This bid is considered to not meet our specification. 2. Graybaes bid for CG units does not induce stray lasses and as such is considered to be non-responsive- 3. Imys bid for Eaton's units includes several exceptions. CTRs will be sent within 30 days of shipment- this is acceptable as long as Fort Collins agreement with Irby still stands to get these immediately after shipment. The exceptions taken regarding paint, leak testing, design temperatures, nameplate, and production tests are acceptable. 4. Wesco's bid for ASS units looks to have all the required information and is an acceptable bid. S. WUE's bid for CG units did riot have the required stray losses information and as such is considered to be non -responsive. 6. WUE's bid for Howard units took exception to the D dimension in Figure 6 of our specification. This figure shows the size of our concrete xfmr pad, not the depth of the cabinet. 23" should be fine; it looks as though the quoted unit will fit on that pad. 7. Irbys bid for 2016 DOE compliant Eaton units includes several exceptions. CTRs, will be sent within 30 days of shipment - this is acceptable as long as Fort Collins agreement with Irby still stands to get these immediately after shipment. The exceptions taken regarding paint, leak testing, design temperatures, nameplate, and production tests am acceptable. Based on the ranking of the evaluated bids, ABB (care of Wasm) is the lowest evaluated responsible bidder and should be awarded this portion of Bid 8110 for 5.500IrVA transformers. IEEE C57.12.00, Section 9.2 Tolerances for impedance The tolerances for impedance shall be as follows: a) The impedance of a two -winding transformer with an impedance voltage greater than 2.5%shall have a tolerance of 27.5%of the specified value, and those with an impedance voltage of 25%or less shall have a tolerance of t10%of the specified value. Differences of impedance between duplicate two -winding transformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed 7.5%of the specified value. b) The impedance of a transformer having three or more windings, or having zigzag windings, shall have a tolerance of t10%of the specified value. Differences of impedance between duplicate three -winding or zigzag transformers, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed 10%of the specified value. c) The impedance of an autotnnsformer shall have a tolerance of t10%of the specified value. Differences of impedance between duplicate autotransfonners, when two or more units of a given rating are produced by one manufacturer at the same time, shall not exceed 10%of the specified value. d) Transformers shall be considered suitable for operetion in parallel when reactances come within the limitations of the preceding paragraphs, provided that turns ratios and other controlling characteristics are sultable for such operation.