HomeMy WebLinkAboutBID - 8058 TRANSFORMERS 100KVA PAD-MOUNTED 1-PHASE8058 Transformer, 100kVA, Pad-mounted, 1 PH Page 1 of 5 INVITATION TO BID 8058 TRANSFORMERS, 100 KVA PAD-MOUNTED, 1 PHASE BID OPENING: 3:00 P.M. (our clock), FEBRUARY 10, 2015 The City of Fort Collins is requesting bids from firms for 100kVA, pad-mounted, 1 Phase transformers. Bid submission via email is preferred. Bids shall be submitted in Microsoft Excel, Word or PDF format and e-mailed to: purchasing@fcgov.com. If electing to submit hard copy bids instead, three (3) copies, will be received at the City of Fort Collins' Purchasing Division, 215 North Mason St., 2nd floor, Fort Collins, Colorado 80524. Bids will be received before 3:00 p.m. (our clock), February 10, 2015 and referenced as Bid No. 8058. If delivered, they are to be sent to 215 North Mason Street, 2 nd Floor, Fort Collins, Colorado 80524. If mailed, the address is P.O. Box 580, Fort Collins, 80522-0580. The City encourages all disadvantaged business enterprises to submit bid in response to all invitations and will not be discriminated against on the grounds of race, color, national origin. Any questions or inquiries regarding this bid should be directed to: Pat Johnson, CPPB, Senior Buyer at (970) 221-6816 or pjohnson@fcgov.com. A copy of the Bid may be obtained by downloading the RFP from the Rocky Mountain E-Purchasing System at www.rockymountainbidsystem.com. Special Instructions All bids must be properly signed by an authorized representative of the company with the legal capacity to bind the company to the agreement. Bids may be withdrawn up to the date and hour set for closing. Once bids have been accepted by the City and closing has occurred, failure to enter into contract or honor the purchase order will be cause for removal of supplier's name from the City of Fort Collins' bidders list for a period of twelve months from the date of the opening. The City may also pursue any remedies available at law or in equity. Bid prices must be held firm for a period of forty- five (45) days after bid openings. Submission of a bid is deemed as acceptance of all terms, conditions and specifications contained in the City's specifications initially provided to the bidder. Any proposed modification must be accepted in writing by the City prior to award of the bid. Only bids properly received by the Purchasing Office will be accepted. All bids should be clearly identified by the bid number and bid name contained in the bid proposal. Financial Services Purchasing Division 215 N. Mason St. 2nd Floor PO Box 580 Fort Collins, CO 80522 970.221.6775 970.221.6707 fcgov.com/purchasing 8058 Transformer, 100kVA, Pad-mounted, 1 PH Page 2 of 5 No proposal will be accepted from, or any purchase order awarded, to any person, firm or corporation in default on any obligation to the City. Bids must be furnished exclusive of any federal excise tax, wherever applicable. Bidders must be properly licensed and secure necessary permits wherever applicable. New Vendors: The City requires new vendors receiving awards from the City to fill out and submit an IRS form W-9 and to register for Direct Deposit (Electronic) payment. If needed, the W- 9 form and the Vendor Direct Deposit Authorization Form can be found on the City’s Purchasing website at www.fcgov.com/purchasing under Vendor Reference Documents. The City may elect where applicable, to award bids on an individual item/group basis or on a total bid basis, whichever is most beneficial to the City. The City reserves the right to accept or reject any and all bids, and to waive any irregularities or informalities. Sales prohibited/conflict of interest: no officer, employee, or member of City Council, shall have a financial interest in the sale to the City of any real or personal property, equipment, material, supplies or services where such officer or employee exercises directly or indirectly any decision-making authority concerning such sale or any supervisory authority over the services to be rendered. This rule also applies to subcontracts with the City. Soliciting or accepting any gift, gratuity, favor, entertainment, kickback or any items of monetary value from any person who has or is seeking to do business with the City of Fort Collins is prohibited. Freight terms: unless otherwise noted, all freight is F.O.B. Destination, Freight Prepaid. All freight charges must be included in prices submitted on proposal. Discounts: any discounts allowed for prompt payment, etc., must be reflected in bid figures and not entered as separate pricing on the proposal form. Purchasing restrictions: your authorized signature of this bid assures your firm's compliance with the City's purchasing restrictions. A copy of the resolutions is available for review in the Purchasing Office or the City Clerk's Office. Request Resolution 91- 121 for cement restrictions. Collusive or sham bids: any bid deemed to be collusive or a sham bid will be rejected and reported to authorities as such. Your authorized signature of this bid assures that such bid is genuine and is not a collusive or sham bid. Bid results will be posted online at www.rockymountainbidsystem.com. Gerry S. Paul Director of Purchasing and Risk Management 8058 Transformer, 100kVA, Pad-mounted, 1 PH Page 3 of 5 FIRM NAME:_____________________________ CITY OF FORT COLLINS 8058 TRANSFORMERS, 100KVA PAD-MOUNTED, 1 PHASE WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR TRANSFORMERS, 100KVA, PAD-MOUNTED, 1 PHASE PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS. QUANTITY: DESCRIPTION: 20 ea. T1200170 TRANSFORMER, 100 kVA PAD-MOUNTED COMPARTMENTAL TYPE, SINGLE PHASE DISTRIBUTION WITH SEPARABLE INSULATED LOAD BREAK HIGH VOLTAGE CONNECTORS. HIGH VOLTAGE RATING: 13200 GRDY/7620. LOW VOLTAGE RATING: 240/120. SERIAL NUMBER 170 TO BE IN ACCORDANCE WITH SPECIFICATION #368-120-170, REVISION GG Please complete the Excel spreadsheet issued separately for bid submittal. The spreadsheet MUST be submitted in Excel format only. IF YOU ELECT TO PASSWORD PROTECT YOUR BID, PLEASE NOTE THAT PASSWORD BELOW. _______________________________ *Any surcharges or additional costs shall be noted & included in bid submittal. The items being bid meet or exceed the specifications. _______ Yes ______No. If not, please list exceptions (specifying paragraph reference number) on a separate sheet of paper and submit with your bid documents. Escalation is _____, is not _____ applicable for the transformers bid. If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof. Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city. Escalation occurring after acceptance, if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid. Delivery lead time may be a consideration of bid award. For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid. 8058 Transformer, 100kVA, Pad-mounted, 1 PH Page 4 of 5 Awards from this bid will be based primarily on the evaluated bid price. Delivery lead times, escalation and exceptions taken will also be considered. The City of Fort Collins reserves the right to split the bid award in whatever percentages are most advantageous to the City. Future orders of Transformers, 100kVA, Pad-Mounted, 1 Phase may be authorized, at the option of the City, from this bid for a period of five years after bid closing date. Satisfactory pricing and delivery is required for future orders based on this bid. Pages 3 and 5 of this bid document comprise the bid submittal, along with the Excel Spreadsheet. Failure to submit any of these in the format requested may cause the submittal to be deemed incomplete and may be subject to rejection. 8058 Transformer, 100kVA, Pad-mounted, 1 PH Page 5 of 5 EXHIBIT A BID ACKNOWLEDGEMENT Contractor hereby acknowledges receipt of the City of Fort Collins Utilities’ Request for Bids for the Transformers and acknowledges that it has read and agrees to be fully bound by all of the terms, conditions and other provisions set forth in the Bid. Additionally, the Contractor hereby makes the following representations to Utilities: a. All of the statements and representations made in this bid are true to the best of the Contractor’s knowledge and belief. b. The Contractor has obtained all necessary authorizations and approvals that will enable the Contractor to commit to the terms provided in this bid submittal. c. This bid submittal is a firm and binding offer, for a period of 45 days from the date hereof. d. I further agree that the method of award is acceptable to my company. e. I acknowledge receipt of addenda. Contractor Firm Name: Physical Address: Remit to Address: Phone: Authorized Agent of Firm Name: Signature of Authorized Agent: Primary Contact for Project: Title: Email Address: Phone: Cell Phone: THE CITY OF FORT COLLINS Light and Power Department P.O. Box 580 Fort Collins, CO 80522 SPECIFICATION NO: 368-120 PAD-MOUNTED COMPARTMENTAL-TYPE, SINGLE-PHASE DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED LOAD BREAK HIGH-VOLTAGE CONNECTORS UPDATED BY: Adam Bromley Senior Electrical Engineer APPROVED BY: Kraig E. Bader Standards Engineering Manager ORIGINATED: 09/14/72 LAST REVISED: 2 April 2013 ITEMS COVERED BY THIS SPECIFICATION DESCRIPTION STOCK NO. SPECIFICATION NO. SERIAL 25 KVA, 120/240 ANSI Type 1 Transformer. 368-120 -130 50 KVA, 120/240 ANSI Type 1 Transformer. 368-120 -150 100 KVA, 120/240 ANSI Type 1 Transformer. 368-120 -170 167 KVA, 120/240 ANSI Type 1 Transformer. 368-120 -180 250 KVA, 120/240 ANSI Type 1 Transformer. 368-120 -190 REV. SYM: GG 2 368-120 PREVIOUS REVISION DESCRIPTIONS ON FILE REVISION DESCRIPTION APPROVED REVISION DD:  Paragraph 3.2.2.7.5: Editorial  Add paragraph 3.2.2.9.4 requiring pentahead locking bolts  Paragraph 3.2.2.13 add glossy to paint requirement  Paragraph 4.2.2: Clarify impedance requirement Sagen 10/21/94 REVISION EE:  Paragraph 5.0: revised pallet size from 28 to 34 inches Sagen 2/25/98 REVISION FF  Added 50kVA ANSI Type 2 Transformer (368-120-155) to Specification  Changed paint color to standard Munsell Green  Reorganized to consolidate impedance and fusing requirements into one table.  Consolidated secondary terminal requirements into one table.  Added maximum impedance requirement for 250kVA transformer (+/-7.5% from nominal for transformers with impedance greater than 2.5%) per ANSI/IEEE C57.12.00-2000.  Re-evaluated fusing requirements of all transformers in this specification. Went from dual sensing bay-o-net (expulsion) fuses to current sensing bay-o-net (expulsion) fuses. Fuse sizing was changed as follows:  Changed 25 kVA from 8A expulsion / 40 amp CL to 10A expulsion / 30A CL  Changed 50 kVA from 15A expulsion / 80 amp CL to 15A expulsion / 40A CL  Changed 100 kVA from 25A expulsion / 175 amp CL to 25A expulsion / 80A CL  Changed 167 kVA from 40A expulsion / 200amp CL to 40A expulsion / 125A CL  Changed 250 kVA from 65A expulsion / 350amp CL to 65A expulsion / 125A CL Kraig Bader 7/21/2004 REVISION GG  Deleted ANSI Type 2, 50 kVA, transformers from the Specification. Fort Collins is no longer purchasing Type 2 transformers because most maintenance situations require Type 1 bushing heights.  Updated all references from ANSI to IEEE standards. The standards development process utilized by IEEE is approved by ANSI, so they do not explicitly place their name on each standard anymore.  Eliminated “Not Used” sections.  Updated references to IEEE C57.12.25, which is no longer active, to now reference IEEE C57.12.38 and the corresponding sections and figures within the new standard.  Added IEEE C57.12.37 – Electronic Reporting of Distribution Transformer Test Data as a reference standard. Amended section 5.1.2 to include details for the application of IEEE C57.12.37.  Added “Operation Test” to the required design tests contained within C57.12.28 to Section 3.1.3.2.  Added section on DOE Energy Efficiency Requirements.  Amended section 3.2.2.4.3 to require that locking nuts be provided on all low-voltage line and neutral terminals. Adam Bromley Kraig Bader 4/3/2013 REV. SYM: GG 3 368-120  Amended section 3.2.2.6.6 to specify a pressure relief device that includes detection and indication of internal transformer faults. The approved device is manufactured by IFD Corporation.  Moved and updated section on Losses (now Section 4) to include new required information to be submitted by manufacturers during the bid process. Additional information to be supplied includes expected winding’s stray losses and losses associated with auxiliary devices such as fuses, breakers, switches, etc. Also updated Special Conditions and Supplemental Instructions to Bidders with new required losses information.  Removed General Electric as an approved manufacturer and added Central Moloney to the Conditionally Approved Manufacturers list.  Deleted Individual Transformer Loss Evaluation Form. Typically, orders include more than one unit and the average form is used. Fort Collins Utilities has always and continues to reserve the right to calculate losses and assess penalties individually, if favorable to Fort Collins Utilities.  Added Special Conditions and Supplemental Instructions to Bidders to the end of this specification. Previously, this had been submitted to Bidders separately. This merge helps to maintain consistency among transformer specifications. REV. SYM: GG 4 368-120 TABLE OF CONTENTS PREVIOUS REVISION DESCRIPTIONS ON FILE ................................................................................................................ 2 1 SCOPE ................................................................................................................................................................................. 5 2 APPLICABLE DOCUMENTS .............................................................................................................................................. 5 3 REQUIREMENTS ................................................................................................................................................................ 5 3.1 GENERAL REQUIREMENTS FOR DESIGN ................................................................................................................. 5 3.2 SPECIFIC DESIGN REQUIREMENTS .......................................................................................................................... 6 4 LOSSES ............................................................................................................................................................................... 9 5 QUALITY ASSURANCE .................................................................................................................................................... 10 5.1 GENERAL .................................................................................................................................................................... 10 5.2 TEST CONDITIONS .................................................................................................................................................... 10 5.3 TESTS ......................................................................................................................................................................... 10 6 PREPARATION FOR DELIVERY ..................................................................................................................................... 11 7 DEFINITIONS AND ABBREVIATIONS ............................................................................................................................. 11 APPENDIX A – TRANSFORMER STOCK NUMBER CODING .......................................................................................... 12 APPENDIX B – DIMENSIONAL DRAWINGS ...................................................................................................................... 13 APPENDIX C – APPROVED MANUFACTURERS .............................................................................................................. 15 TRANSFORMER LOSS EVALUATION - AVERAGE LOSSES .......................................................................................... 16 SPECIAL CONDITIONS AND SUPPLEMENTAL INSTRUCTIONS TO BIDDERS APPLICABLE TO SPECIFICATION 368-120 ................................................................................................................................................................................. 17 1 SC T di 13 fo T tra 2 AP T do 3 RE 3.1 COPE his Specificat ielectric fluid- 3,200 Grd Y/7 or step down p his standard g ansformers, C PPLICABLE he following d ocument is no  IEEE C Transf  IEEE C  IEEE C  IEEE C Voltag  IEEE Transf  IEEE C  IEEE C  IEEE C  IEEE 3 EQUIREMEN GENERAL R 3.1.1 BASIC Trans requir parag a) b) 3.1.2 KILOV Kilovo tempe 65°C The tr 3.1.3 GENE 3.1.3. cable termin WITH SE tion establishe immersed, se 7620 volts, w purposes from generally con C57.12.38. DOCUMEN documents fo REV. SYM: GG 6 368-120 mounting on a pad. There shall be no exposed screws, bolts, or other fastening devices which are externally removable. The cover shall be welded construction. There shall be no opening through which foreign objects such as sticks, rods, or wires might be inserted to contact live parts. Suitable means for padlocking the compartment door(s) shall be provided. 3.1.3.2 In addition to the enclosure security design tests listed in Section 4.3.1 of IEEE C57.12.28, the manufacturer shall perform an “Operation test”. The unit shall be lifted, utilizing provided lifting lugs, at least one meter in accordance with the manufacturer’s standard lift instructions and then set again on a flat surface. The doors shall be easily opened, closed, latched and locked without requiring adjustments to the cabinet, latch mechanism and/or enclosure door(s). All of the door latch points must fully engage when the door is closed. 3.1.3.3 The high- and low-voltage compartment shall be located side by side on one side of the transformer tank. When facing the compartment, the low-voltage side shall be on the right. 3.1.3.4 Construction of the unit shall be such that it can be lifted, skidded, and slid into place on the mounting pad without disturbing the entrance cables. 3.1.3.5 An undercoating over the regular finish or an equivalent treatment shall be applied to all surfaces that are in contact with the pad to minimize corrosion. 3.1.3.6 Minimum dimensions for Type 1 transformers shall be as shown in Figure 1, Appendix B. 3.1.4 ENERGY EFFICIENCY Transformers shall be designed to meet the minimum energy efficiency ratings defined in the United States Department of Energy October 12, 2007 Final Rule: 10 CFR Part 31, Energy Conservation Program for Commercial Equipment: Distribution Transformers Energy Conservation Standards. 3.2 SPECIFIC DESIGN REQUIREMENTS 3.2.1 FUNCTIONAL DESCRIPTION The transformer shall be a single phase, pad mounted, loop feed-safe break, "dead-front" type for use on a 13.8 kV grounded "Y" distribution system. 3.2.2 DESIGN AND CONSTRUCTION 3.2.2.1 RATING The transformer shall be rated as follows: a) High Voltage 13,200 Grd Y/7620 volts b) Low Voltage 240/120 c) Taps Two - 2½% FC above and below normal d) Polarity Additive e) Capacity, Impedance values, and fusing for transformers in this specification shall conform to Table 1. 3.2.2.2 OVERCURRENT PROTECTION An RTE / Cooper Power Systems BAY-O-NET current sensing fuse and internally mounted partial range current limiting fuse shall be furnished as shown in Table 1. REV. SYM: GG 7 368-120 Table 1 – Transformer Capacity, Impedance and Fuse Selection Stock Number kVA Capacity Min. Impedance Max. Impedance Bay-O-Net Fuse1,2 Current Limiting Fuse(s)2 368-120-130 25 1.77% 2.16% 10 Amp 4000353C06 ELSP 3544030M61M (30 A) 368-120-150 50 1.77% 2.16% 15 Amp 4000353C08 ELSP 3543040M61M (40 A) 368-120-155 50 1.77% 2.16% 15 Amp 4000353C08 ELSP 3543040M61M (40 A) 368-120-170 100 1.95% 2.38% 25 Amp 4000353C10 ELSP 3543080M71M (80 A) 368-120-180 167 2.28% 2.79% 40 Amp 4000353C12 ELSP 3543125M71M (125 A) 368-120-190 250 5.75% 6.61% 65 Amp 4000353C14 ELSP 3543125M71M (125 A) 1 The BAY-O-NET fuse shall be located in the high voltage side of the compartment. 2 The approved manufacturer for the fuses is Cooper Power Systems. Other fuses meeting the requirements defined in this specification shall be specifically approved in writing by Fort Collins Utilities Engineering Standards Division 3.2.2.3 INSULATION LEVEL 3.2.2.3.1 The basic impulse insulation level (BIL) of completely assembled high-voltage and low-voltage terminals shall be 95 kV and 30 kV respectively. 3.2.2.3.2 Dielectric test levels shall be in accordance with the distribution levels in Section 4 of ANSI C57.12.00. 3.2.2.4 HIGH-VOLTAGE TAPS A no-load tap changer with external operating handle shall provide two - 2½% full capacity taps above and below normal. The tap changer operating handle shall be located within the high-voltage terminal side of the terminal compartment. 3.2.2.5 BUSHING WELLS AND TERMINALS 3.2.2.5.1 The number, location, and arrangement of bushing wells, terminals and parking stands shall be as shown in Fig. 1 in Appendix B. All low-voltage bushings and high-voltage wells shall be externally clamped and shall have leads of sufficient length to allow them to be changed without removing the cover. Welded bushings and wells are expressly prohibited. 3.2.2.5.2 High-voltage bushing wells shall be 200 A load-break interface 8.3/14.4 kV bushings in accordance with IEEE 386. Two wells shall be provided and shall be connected in a feed-through configuration. Loadbreak bushing inserts in accordance with IEEE 386 will be purchaser furnished. 3.2.2.5.3 Low-voltage line and neutral terminals shall be sized as shown in Table 2 in accordance with IEEE C57.12.38. Bushing arrangement and spacing shall be as shown in Fig. 1 in Appendix B. All low- voltage line and neutral terminals shall be equipped with locking nuts. Table 2 – Low Voltage Terminal Sizes 3.2.2.5.4 The low-voltage X2 bushing shall be a fully insulated bushing. A ground pad shall be provided REV. SYM: GG 8 368-120 3.2.2.5.5 The high-voltage neutral shall be securely grounded internally. 3.2.2.6 ACCESSORY CABINET 3.2.2.6.1 The accessory cabinet shall consist of a compartment containing high- and low-voltage bushings constructed in accordance with applicable IEEE specifications, including IEEE C57.12.28. Dimensions shall be in accordance with Fig. 1 of this specification. 3.2.2.6.2 Cabinet doors shall be hinged, removable, lockable, and of sufficient size to provide adequate working space when removed or open. Unlocking the padlock shall permit access to both the high- and low-voltage terminations. Stainless steel hinge pins shall be provided. 3.2.2.7 ACCESSORY EQUIPMENT Accessory equipment shall be provided in accordance with the following details: 3.2.2.7.1 The transformer base shall be arranged for rolling in two directions: Parallel to and at right angles to the center line of the high-voltage bushings. 3.2.2.7.2 Lifting lugs or bosses for screw-in lift bolts shall be provided. These lugs or bosses shall be adequate strength and size and arranged on the tank to provide a suitable balanced lift for the completely assembled unit. 3.2.2.7.3 The base of the assembly shall be provided with suitable means for mounting the unit on the pad. An internal flange shall be provided at the base of the accessory compartment to provide means for mounting the unit on the pad. (Fig. 1, Appendix B). 3.2.2.7.4 Terminal designations are shown in Figure 1, Appendix B. The identification of terminal connections shall be shown on the instruction nameplate. Instruction nameplate shall be located in the low-voltage side and shall be readable with cables in place. Where the nameplate is mounted on a removable part, the manufacturer's name and transformer serial number shall be permanently affixed to a non-removable part. Instruction nameplate shall contain the information specified in 5.12 of IEEE C57.12.00-2010. Also, on the nameplate, or label affixed near it, the manufacturer shall indicate that the dielectric fluid contains less than 1 ppm PCB. 3.2.2.7.5 A suitable marking inside of the tank shall indicate the correct oil level at 25°C. 3.2.2.7.6 A non-resettable device which detects and provides external indication of internal transformer faults, as well as incorporating automatic pressure relief functionality shall be provided. The pressure relief device shall meet the following requirements:  ¼" NPT or larger male Inlet Port.  Exposed parts of weather and corrosion resistant materials.  Non-deteriorating gasket and o-ring material.  Manual pull ring able to withstand a static force of 25 pounds for 1 minute without permanent deformation. The valve shall also withstand for 1 minute a static force of 100 lbf applied normal to its longitudinal axis at the outermost extremity of the body.  Bug shield to prevent entry of dust, moisture, and insects before and after the valve has operated.  Cracking pressure of 10 ± 2 psig.  Resealing pressure of 8 ± 2 psig.  Zero leakage from resealing pressure to -8 psig.  Minimum flow rate of 35 SCFM at 15 psig. The approved manufacturer for this device is IFD Corporation. Other devices meeting the requirements defined in this specification shall be specifically approved in writing by Fort Collins Utilities Engineering Standards Division. 4 LO The t tests dupli Supp rates addit spec and t Exce Loss be gi If any witho equa Exce (Load 3.2.2. Trans the ta will re 3.2.2. The ta minim parag 3 3 7/ 3 on co 3 3.2.2. The m ampe 3.2.2. The a 3.2.2. The b dimen 3.2.2. EEI "F 3.2.2. NEMA labels OSSES total losses o shall be perf cate units. Lo plemental Inst s. If tested los tional cost inc ified rates an the following ess loss $ = [N Evaluation $ ven the Supp y unit or units out express pe ation: Quot     All qu witho Collin 5 QU 5.1 5.2 T U 5.3 T T a ted losses sub  No load lo  Full load l losses ass  Winding’s  Losses as uoted loss va out the require ns. UALITY ASS GENERAL 5.1.1 RESP Unles specif labora of the 5.1.2 TEST The m data a cover The e 4.2 an as sp Sectio addre TEST CONDIT Unless otherw 5.2.1 REFE The re 85°C. 5.2.2 TOLER Imped 5.2.3 TOLER The p voltag TESTS The kinds of t and C57.12.9 5.3.1 DIELE No ap termin 1000 bmitted by ma osses osses – it sha 6 PR Trans Units Units acco trans weig or mo 7 DE Vend Artic          5.3.2 IMPED Imped tests REPARATIO sformers sha s shall be pac s shall be fully mmodate min sformer. The S hs over 5,000 odifications s EFINITIONS dor or Suppli cle, Unit, Ass DC or d.c. AC or a.c. °C - Degre °F - Degree kV - 1000 v CPS or Hz psig - Pou V or v - Vo KVA - 100 DANCE AND dance and loa made on a du ON FOR DEL ll be prefilled ckaged in suc y palletized on nimum fork sp Supplier shall 0 pounds. In hown on the AND ABBR er - The man embly - All re - Direct Curre - Alternating ee Celsius (Ce REV. SYM: GG 12 368-120 APPENDIX A – Transformer Stock Number Coding Below are examples that demonstrate the coding method used by City of Fort Collins to establish transformer stock numbers. I. SINGLE PHASE Example #1: 368 - 1 BC - X Y Z II. THREE PHASE Example #2 368 - 300 - XYZ Other KVA 0 = 5 5 = 50 1 = 10 6 = 75 2 = 15 7 = 100 3 = 25 8 = 167 4 = 37.5 9 = 250 1 = single voltage 2 = dual voltage Transformer 00 = 13.2Y/7620 & 7620/13.2Y x 2400/4160 outside pole 05 = 13.2Y7620 ESNA pole 20 = 13.2Y/7620 ESNA pad Single Phase Transformer 3 Phase Pad KVA 006 = 75 075 = 750 015 = 150 100 = 1000 030 = 300 150 = 1500 050 = 500  All suffixes indicate 208Y/120 sec.  For 480Y/277 sec., add 1 to XYZ (ie. 007 would indicate a 75kVA with 480Y/277 sec.) REV. SYM: GG 13 368-120 APPENDIX B – DIMENSIONAL DRAWINGS Figure 1 – Type 1 Transformer Dimensions and bushing Designations (not to scale) REV. SYM: GG 14 368-120 Pad Dimensions This drawing is not intended to dictate requirements for items purchased under Specification 368-120 but is included as an aid to those users desiring a minimum of pad designs for the transformers covered by Specification 368-120. The dimensions in inches of Figure 2 will fit the minimum compartments on transformers covered by this Specification as well as the maximum transformer envelope. Figure 2 – Pad Dimensions 3" 3" 3" LENGTH AND WIDTH FOUR #3 REBAR 3" 3" FRONT 12" PRIMARY SECONDARY 12" 4 1/2" 18" 48" 48" 7 1/2" Notes on Pad Material - 1. Concrete must be 3,000 psi minimum. 2. Maximum coarse aggregate size 1 1/2 inches. Space requirements for pad and primary switching cabinet will generally be 9' X 12'. Factors to be considered in locating the pad include - 1. Accessibility - The transformer pad shall be accessible to line boom trucks equipped for the installation and removal of heavy transformers. Such accessibility shall not require intrusion on adjacent property. 2. Proximity of Buildings, Walls, Barriers, and/or Overhangs - In addition to the clearances required for installation and removal, the minimum clearance in front of the transformer pad shall be eight (8) feet and the minimum clearance from all other sides shall be two (2) feet. If the building has an overhang, clearance to the edge of the transformer pad shall be measured horizontally from the outer edge of the overhang. Transformers through 300 KVA may be installed under the overhang if the vertical clearance between the pad and the overhang is at least 25 feet and the location is accessible to line boom trucks. 3. Codes and Standards - In addition to the above, the installation shall conform to the National Electric Code and federal, state and city codes and standards. 2" 15" 6" 15" REV. SYM: GG 15 368-120 APPENDIX C – Approved Manufacturers Transformers purchased under this Specification shall be of the make shown below. Manufacturers not listed below may submit written proposals demonstrating compliance with these Specifications for consideration of addition to the accepted manufacturers list prior to the next request for bids. In addition to inclusion on the list below, manufacturer's equipment must also satisfy all requirements of this Specification to be acceptable. Approved manufacturers must have constructed and submitted prototype units for inspection and deemed satisfactory by the Fort Collins Utilities Electric Department. APPROVED MANUFACTURERS ABB Cooper Power Systems Howard Industries The manufacturers in the following list have been conditionally approved and may bid as an alternate. The definition and intent of "Conditional Approval" of a manufacturer is to allow the City to gain some experience with the manufacturer's product. In order to be added to the Conditionally Approved List, the manufacturer shall submit drawings demonstrating that their design meets technical and dimensional requirements contained within this Specification. Should a conditionally approved manufacturer be the evaluated low bidder, the City reserves the right to award all, part, or none of the order to them, dependant upon the current needs of the City for that item or items. CONDITIONALLY APPROVED MANUFACTURERS Central Moloney REV. SYM: GG 16 368-120 TRANSFORMER LOSS EVALUATION - AVERAGE LOSSES City Order No. __________________________ S/N __________________________________ Manufacturer ___________________________ Invoice No. __________________________ KVA/Unit _____________________________ LINE DESCRIPTION AMOUNT (1) No. of units ________ (2) Average core losses ________ (3) Quoted core losses ________ (4) Excess average core losses: line (2) less line (3) ________ (5) Penalty for excess average core losses: line (1) x line (4) x $____________ ________ (6) Average copper losses ________ (7) Quoted copper losses ________ (8) Excess average copper losses: line (6) less line (7) ________ (9) Penalty for excess average copper losses: line (1) x line (8) x $_______________ ________ (10) Penalty to be assessed manufacturer: line (5) plus line (9) but not less than zero ________ Date ______________________________ Prepared By: _____________________________ Design Engineering NOTE: If any unit(s) exceeds the loss tolerances of IEEE C57.12.00, Utilities Electric Department will (1) either reject it, (2) include it on these averages, or (3) calculate losses and assess penalties individually, whichever is most favorable to Utilities Electric Department. REV. SYM: GG 17 368-120 Special Conditions and Supplemental Instructions to Bidders Applicable to Specification 368-120 A. Data to be supplied with Bidder's Proposal The following data shall be supplied with the bidder's proposal in addition to that information required by the "Invitation to Bid" and the "Purchase Requisition". 1. Impedance volts in percent (%) at full load, high voltage to low voltage at 85°C 2. No load losses, full load losses, total losses, expected winding’s stray losses, auxiliary devices’ losses all corrected to a reference of 85°C. Please see Section 4 – Losses for more information. 3. Delivery in weeks 4. A statement indicating compliance with our Specification with exception or a detailed list of exceptions. 5. Escalation IS ______ / IS NOT ______ applicable for the transformers bid. If escalation applies, the Bidder shall indicate in his bid, the specific items or materials subject to escalation and shall provide the method and indices to be used in computing the amount thereof. Escalation occurring after acceptance, if Purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid. If the above information and compliance statement are not supplied the proposal will not be evaluated. An alternate bid for the total order may be submitted in addition to the unit bids. B. Loss Evaluations Loss penalties and loss evaluations will be based on the following values: 1. No-load or excitation losses at $3.90/watt 2. Load losses at $1.50/watt C. Shipping Terms Ship F.O.B. point of destination, freight prepaid. D. Terms of Payment 1. If escalation applies, the City of Fort Collins shall not be billed for escalation occurring after the promised delivery date. 2. Electronic test reports as describe in Section 5.1.2 sent via E-mail shall accompany the invoice sent to the Material Control Section. If test reports do not accompany the invoice, late payment penalty charges incurred due to delays in obtaining the test reports will not be paid. Electronic test reports shall also be sent via E-mail to Engineering Standards Division, Fort Collins Utilities - Light & Power. 3. Loss penalty credits and escalation charges shall be itemized on the invoice. e Fahrenheit volts. z - Cycles per nds per squa olts. 0 Volt-ampere LOAD-LOSS ad-loss tests s uplicate unit is LIVERY with the appr h a way as to n two-way pa pacing) and lo l give 24 hour addition to th purchase ord REVIATIONS ufacturer and efer to the equ ent. Current. entigrade) second. re inch gauge es. TESTS shall be made s available. ropriate amou o provide for e llets or four-w oaded on the r notice prior t ese requirem er and/or sup S /or manufactu uipment define e. e on each un unt of transfor ease of handl way universal truck for side to delivery for ments, the Sup pplemental ins urer's agent su ed by this Spe it and may no rmer oil and s ing and to pro pallets with 3 e removal. Pa r any shipme pplier shall co structions. upplying or qu ecification. ot be omitted shall be shipp otect units fro 30” minimum allets shall be nts where an omply with an uoting on the RE 11 368- even if a reco ped by open-b om shipping d openings (to e independent individual tra ny additional r specified artic EV. SYM: GG 1 120 ord of such bed truck. damage. t of the ansformer requirements cle. G sociated with s expected str ssociated with lues shall be ed losses info SURANCE ONSIBILITY ss otherwise s fied herein. E atory accepta e inspections s REPORT manufacturer as specified in r letter. The m electronic repo nd 4.3, respec ecified in sec on along with esses shall be TIONS wise specified RENCE TEM eference tem RANCE ON IM dance on com RANCE ON IM percent depar ge shall not be ests to be pe 0 except as s ECTRIC TEST pplied potentia nals of one w volts plus 3.4 anufacturers all be clearly auxiliary dev ray losses rela h auxiliary dev corrected to a ormation shal FOR INSPEC specified, the Except as oth able to the City set forth in th shall furnish t n IEEE C57.1 manufacturer’ orts shall inclu ctively, of IEE tion 5.3 of IEE the invoice, a e provided to d, testing requ PERATURE perature to w MPEDANCE mpleted units MPEDANCE rture of tested e greater than rformed and t specified here TS al test shall b inding a volta 46 times the ra shall include stated whethe vices ated to quote vices such as a reference te l be deemed CTION vendor is res erwise specif y of Fort Colli is Specificatio to the purcha 2.37. Unsign s Quality Con ude the stand EE C57.12.37 EE C57.12.37 and to the En manufacturer uired by Sectio which losses, i VOLTAGE shall fall with VOLTAGE O d impedance v n the total tap the test proce ein. e made. The age which will ated transform the following: er this numbe d transforme s fuses, break emperature o unresponsive sponsible for t fied, the vend ins Utilities. T on where suc ser, prior to p ed copies are ntrol Manager dard data set 7-2006. These 7-2006. Thes gineering Sta r upon award on 5.4 shall b impedance, r in the range s N A TAP voltage on an p voltage rang edures shall b e induced-pot develop from mer winding v : er includes th r design kers, switches of 85˚C. Quota e and are sub the performan dor may utilize The City rese ch inspections payment, elec e not accepta r shall review and the exten e reports shal se reports sha andards Divis of bid. be conducted regulation, an specified here ny tap from te ge expressed be as specifie tential test sha m high-voltage voltage. e winding’s e s, etc. ations submit bject to rejecti nce of all insp e his own faci erves the right s are deemed ctronic reports able even if ac w and approve nded data set ll be formatted all be sent to t sion via Electr under the fol d efficiency a ein. sted impedan as a percent ed in IEEE C5 all be made b e line termina RE 10 368- expected stray tted during the on by the City pection requir ilities or any c t to perform o d necessary. s including tra ccompanied b e each test rep t as specified d in a comma the Material C ronic Mail (E- lowing condit are corrected nce voltage a tage of the ra 57.12.20, ANS by applying be als to ground a EV. SYM: GG 0 120 y losses and e bid process y of Fort rements as commercial or witness any ansformer tes by a signed port. d in sections a delimited file Control mail). E-mail tions: shall be t rated ted voltage. SI C57.12.00, etween the a voltage of G s y st e ess loss $ = (N d Loss Evalua 8 OIL PRES sformers shall ank from the a emain effectiv 9 TANKS ank shall be d mum of 500 lb graphs 6.1 and .2.2.9.1 The c .2.2.9.2 Tank /16 inch deep .2.2.9.3 These ne in the high ompartments .2.2.9.4 Locki 10 COMPON minimum curre eres (continuo 11 AUDIBLE audible sound 12 BASE PL base plan of a nsions shown 13 PAINT Finishing Guid 14 SAFETY A 1260 Safety s after delivery f a transforme formed and re oss evaluatio tructions to B sses exceed q curred from th d will be dedu equation “Un No. of units] [( $) (Avg. Load plier. s exceed the t ermission fro No Load Loss ation $) (Load ERVATION l be of sealed atmosphere, a ely sealed for domed or slop s. vertical loa d 6.6. cover shall be grounding pr p. e ground pad h-voltage side are separate ng bolts shall NENTS FOR ent-carrying c ous) and 10,0 E SOUND LEV level shall be LAN a completely a in Fig. 1B. delines" spec LABELS y Labels shal y. er shall be the eported on all ons and loss c idders.” Tran quoted losses he differential ucted from the its” shall mea (No Load Los Losses – Quo tolerances of m the City. If s Evaluation $ d Losses – Q d-tank constru and in which t r a top-oil tem ped to shed w ad. Construct e welded cons rovision shall ds shall be we e and one in th e, provisions s l be pentahea LOOPED PR capability of c 00 amperes s VEL e in accordan assembled un cification shall l not be applie e sum of the e units regardl costs will be b nsformers will s but are with of losses will e original Pur an “Transform ss Evaluation oted Load Lo paragraph 9. f accepted, th $) (No Load L uoted Losses uction. Seale the gas plus t mperature ran water. The ta tion of the tan struction. consist of two elded on the tr he low-voltag shall be made ad. RIMARY components fo symmetrical ( nce with NEM nit shall be su l apply. Finis ed by the ma excitation los ess of whethe based on the v be evaluated hin the toleran be calculated rchase Order mers of the sam $) (Avg. No L osses)]. If this 3, IEEE C57. he deduction f Losses – Quot s) But Not Les d-tank constr the oil volume ge of -5°C to ank shall be o nk shall be in o steel pads, ransformer ba ge side. In ca e for electrica or the looped (momentary). A Standard T uch that it can h coat shall b nufacturer; P ses and the l er or not a re values shown d on excitatio nces of parag d using the fo or back char me size and d Load Losses s equation res .12.00-2010, for excess los ted No Load ss Than Zero ruction is that e remains con 105°C. of sufficient st accordance w each with ½ ase or on the ases where th ally connecting primary cabl TR1-1980. n be installed be Munsell Gr urchaser will oad losses (I2 cord of such n in the “Spec n losses and raph 9.3, IEE ollowing equa rged to the ma design on one – Quoted No sults in a neg that unit or un sses will be b Losses) But N . RE 9 368- which seals nstant. The tr trength to sup with ANSI C5 inch - 13 NC e tank wall nea he transforme g them. e system sha on a pad of th reen, glossy. apply custom 2R losses). L tests is availa cial Condition I2R losses at EE C57.12.00 ation and the a anufacturer. e order.” Load Losses ative number nits shall not ased on the f Not Less Tha EV. SYM: GG 9 120 the interior of ransformer pport a 7.12.25-1981 tapped hole, ar the base, r tank and all be 200 he m warning Load loss able on s and t the specified -2010, the above In Table 18 s) + (Load r no credit wil be shipped following an Zero + G f , d l on the outer surface of the tank and an external removable copper ground strap shall be provided and connected between the low-voltage X2 bushing and the ground pad. Stock Number kVA Capacity Low voltage Terminal Size 368-120-130 25 5/8" x 11” UNC-2A copper studs 368-120-150 50 5/8" x 11” UNC-2A copper studs 368-120-170 100 1” x 14” UNC-2A copper studs 368-120-180 167 1" x 14” UNC - 2A copper studs 368-120-190 250 1¼" x 12 UNF - 2A copper studs. ot dated, the C57.12.00 – S formers C57.12.28 – S C57.12.37 – S C57.12.38 – S e, 34 500 Grd C57.12.70 – formers C57.12.80 – S C57.12.90 – S C57.91 – Guid 386 – Separab NTS REQUIREMEN C DESIGN ST sformers purc rements of the graphs. In cas ) This Specifi ) Applicable I VOLT-AMPER olt-ampere rat erature or an when measu ransformers s ERAL CONST 1 The pad-m terminating c nating compa PA SINGLE PARABLE IN es the minimu elf-cooled, pa ith separable m an undergro nforms to IEE NTS orm a part of t latest issue in Standard for G Standard for P Standard for th Standard for dY/19 920 V a Standard fo Standard Term Standard Test de for Loading ble Insulated NTS FOR DES TANDARDS hased under e applicable I se of conflict, ication IEEE Standar RE TEMPERA tings are cont 80°C hot spo red near the t shall be desig RUCTION mounted-type compartment artment and ta SPEC D-MOUNTED E-PHASE DIS NSULATED L um electrical d-mounted di insulated loa ound primary E requiremen his Specificat n effect on the General Requ Pad-Mounted he Electronic Pad-Mounted and Below, Lo or Standard T minology for P t Code for Liqu g Mineral-Oil-I Connectors fo SIGN these Specifi EEE Standar the requirem rds ATURE RATIN tinuous and a ot temperature top of the tan gned for overlo transformers constructed i ank shall be a CIFICATION D COMPARTM STRIBUTION LOAD BREAK requirements istribution tran ad break high y cable supply nts for pad-mo tion to the ext e date of invit uirements for Equipment – Reporting of D d-Type, Self-C ow Voltage, 24 Terminal Mar Power and Dis uid-Immersed Immersed Tra or Power Distr ications shall rds and the m ments of the fo NGS are based on e rise. The te nk. The tempe oads based o shall consist n accordance assembled as FOR MENTAL-TYP TRANSFOR K HIGH-VOLT s and mechan nsformers rat voltage conn y. ounted-type, tent specified tation for bids Liquid-Immer Enclosure Int Distribution Tr Cooled, Single 40/120 V; 167 rkings and C stribution Tran d Distribution, ansformers an ribution Syste be new and, modifications a ollowing docu not exceedin emperature ris erature rise is on IEEE C57. t of a transform e with IEEE C s an integral u PE RMERS TAGE CONN nical features ted 250 KVA nectors. Thes self-cooled, s d herein. In th s shall form a rsed Distribut tegrity ransformer Te e-Phase Distr 7 kVA and Sm Connections f nsformers Power, and R nd Step-Volta ems above 60 unless otherw and additions uments shall a ng either a 65° se of the insu s based on an 91. mer tank and C57.12.28 and unit, tamperpr RE 5 368- ECTORS of single pha and smaller, se transforme single-phase, hose cases w part of this S ion, Power, a est Data ribution Trans maller for Distributio Regulating Tra ge Regulators 00 V wise specified s given in the apply in the p °C average w ulating oil sha n altitude of 3 d a high and lo d C57.12.38. roof and weat EV. SYM: GG 5 120 ase, 60 HZ, high voltage ers are used distribution when the pecification. and Regulating sformers; High on and Powe ansformers s d, meet the subsequent riority shown: winding ll not exceed 3,300 feet. ow-voltage The therproof for G g h er