HomeMy WebLinkAboutCORRESPONDENCE - PURCHASE ORDER - 9200988A. ALL DIMENSIONS ARE TO FACE OF STUD, CMU AND/OR CONCRETE UNLESS
NOTED OTHERWISE.
B. ALL NEW WORK SHALL BE PLUMB TRUE, AND LEVEL UNLESS OTHERWISE NOTED.
C. DISSIMILAR FLOOR MATERIALS SHALL MEET UNDER CENTER OF DOOR LEAF.
D. U.N.O. ALL PAINTED SURFACES TO RECEIVE A MINIMUM OF ONE (1) PRIMER COAT
AND THEN TWO (2) FINISH PAINT COATS.
a. WALL SURFACES: EGG SHELL (SATIN) NON-RESTROOM AREAS
b. WALL SURFACES: SEMI-GLOSS - RESTROOM AREAS
c. HOLLOW METAL DOOR FRAME: SEMI-GLOSS
E. U.N.O. ALL EXPOSED STRUCTURE, DUCT WORK, PIPING & CONDUITS TO BE
PAINTED.
PLAN GENERAL NOTES
3 A1.1
5
4
101 102
4'-8" 9-1
4'-8"
5'-3 3/8" 4'-11"
3'-8"
9-2
9-3
9-1
9-2
9-3
1
1
1A
9-4
9-5 9-5
D6-1
D6-1
D6-1
D8-1
D9-1
D9-1
D6-1
D9-2
D9-3
T8
6" TILE BASE W/
SCHLUTER STRIP
T6
T7
T9
T1
T2
T3
5'-0"
T4
WALL TILE BASE W/
SCHLUTER STRIP
T1
T2
T3
T4
5'-0"
WALL TILE BASE W/
SCHLUTER STRIP
A. EXISTING CONSTRUCTION SHOWN DASHED IS TO BE DEMOLISHED –
RECESSED DOWNLIGHT w/ EMERGENCY BALLAST/DRIVER - CEILING MTD.
a
DUPLEX RECEPTACLE - MOUNTED 6" ABOVE COUNTER
MAGNETIC STARTER
SAFETY SWITCH - FUSIBLE
SAFETY SWITCH - NON-FUSIBLE
EQUIPMENT - MOTOR
BRANCH CIRCUIT PANELBOARD - FLUSH MOUNTED
BRANCH CIRCUIT PANELBOARD - SURFACE MOUNTED
POWER
RECESSED DOWNLIGHT - CEILING MOUNTED
LIGHTING
AUTOMATIC TRANSFER SWITCH
METER
CIRCUIT BREAKER
GROUND
FIRE ALARM
ONE-LINE DIAGRAM
GENERATOR
DELTA-WYE TRANSFORMER
SWITCH
SERVICE DROP
SHUNT TRIP PUSH BUTTON - MOUNTED 46" AFF
CONDUIT - CAPPED
CABLE TRAY
SEALING FITTING
EXPANSION FITTING
CONDUIT FITTING (CONDULET)
JUNCTION BOX
CONDUIT - FLEXIBLE
CONDUIT - CONTINUED
CONDUIT - CONCEALED BELOW
SLAB OR GRADE
CONDUIT - UP AND DOWN
(CHANGE IN ELEVATION)
CONDUIT - TURNING UP
CONDUIT - EXPOSED
CONDUIT - CONCEALED IN
SUSPENDED CEILING OR WALL
CONDUIT - TURNING DOWN
REVISION CALL-OUT
ROOM NUMBER
FEEDER CALL-OUT
KEYNOTE
MECHANICAL EQUIPMENT CALL-OUT: REFER TO
THE EQUIPMENT DATA SCHEDULE FOR DETAILS
GENERAL
JUNCTION BOX - EMERGENCY POWER
FOOD SERVICE EQUIPMENT DESIGNATION
WIRING AND CONDUITS
NEW EQUIPMENT (TYPICAL)
EXISTING EQUIPMENT (TYPICAL)
DEMOLITION EQUIPMENT (TYPICAL)
WALL MOUNT BRACKET (TYPICAL)
CARBON MONOXIDE DETECTOR
LUMINAIRE - SURFACE MOUNTED
OPEN INDUSTRIAL LUMINAIRE
RECESSED LUMINAIRE CONNECTED TO THE
EMERGENCY POWER SYSTEM OR BALLAST/DRIVER
OPEN INDUSTRIAL LUMINAIRE
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
ISSUE:
# DATE: DESCRIPTION:
NOT FOR CONSTRUCTION
DESIGNED:
4/8/2020 10:32:47 AM
E0.2
GENERAL
INFORMATION
JPG
APC
0200100.04
Downtown Transit
Center - Restroom
Upgrades
City of Fort Collins
250 N. MASON ST. FORT
COLLINS, CO
04.08.2020
INM
90% CD
6. MAXIMUM SIX FOOT FLEXIBLE FIXTURE WHIP SHALL BE USED FOR FINAL CONNECTIONS TO
LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS. MAXIMUM FOUR LIGHT FIXTURE WHIPS SHALL BE
CONNECTED FROM ONE JUNCTION BOX. FEED THRU BETWEEN LIGHT FIXTURES SHALL NOT BE
ALLOWED.
5. NO SHARING OF NEUTRALS ALLOWED. CIRCUIT SHALL HAVE DEDICATED NEUTRAL CONDUCTORS.
ONE CIRCUIT, ONE NEUTRAL.
4. DERATING OF CONDUCTOR AMPACITY SHALL BE APPLIED PER NEC.
3. EACH RACEWAY SHALL CONTAIN AN INSULATED EQUIPMENT GROUNDING CONDUCTOR PER NEC.
2. MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG. #10 AWG SHALL BE USED FOR HOME RUNS OF 20 AMP
BRANCH CIRCUITS OVER 100 FEET IN LENGTH.
1. MINIMUM CONDUIT SIZE SHALL BE 3/4".
T. WHERE CONDUIT AND WIRING RUNS ARE NOT SHOWN ON FLOOR PLANS, THE CONTRACTOR SHALL
DETERMINE AND PROVIDE THE REQUIRED CONDUIT AND WIRING FOR SPECIFIED CIRCUITING IN
ACCORDANCE WITH NEC AND THE FOLLOWING MINIMUM REQUIREMENTS:
S. IF POSSIBLE, ALL NEWLY INSTALLED RECEPTACLES SHALL BE INSTALLED IN SEPARATE OR ADJACENT
STUD SPACES, TO AVOID SOUND TRANSMISSION AND WALL INTEGRITY ISSUES. ALL NEWLY INSTALLED
RECEPTACLES LOCATED IN COMMON STUD SPACES OF FIRE-RESISTANT WALLS SHALL BE EQUIPPED
WITH FIRE-RESISTANT PUTTY PADS AT THE BACK OF EACH BOX IN ACCORDANCE WITH NEC.
R. CONTRACTOR SHALL NOT SCALE DRAWING FOR QUANTITIES. CONTRACTOR IS RESPONSIBLE FOR FIELD
VERIFYING ALL MEASUREMENTS.
Q. UNLESS INDICATED IN SOME MANNER THAT ELECTRICAL EQUIPMENT IS EXISTING, ALL EQUIPMENT SHALL
BE NEW.
P. PRIOR TO SUBMITTING BID PROPOSAL, BIDDER SHALL EXAMINE ALL GENERAL CONSTRUCTION DRAWINGS
AND VISIT CONSTRUCTION SITE TO BE FAMILIAR WITH EXISTING CONDITIONS UNDER WHICH HE WILL
HAVE TO OPERATE AND WHICH WILL IN ANY WAY AFFECT THE WORK UNDER THIS CONTRACT. NO
SUBSEQUENT ALLOWANCE WILL BE MADE IN THIS CONNECTION ON BEHALF OF THE CONTRACTOR FOR
ANY ERROR OR NEGLIGENCE ON HIS PART.
O. PROVIDE AND INSTALL IN EACH PANEL, TYPEWRITTEN NEAT TWO-COLUMN CIRCUIT INDEX CARD SET
UNDER PLASTIC COVERS ON INSIDE OF DOORS. EACH ODD-NUMBERED CIRCUIT SHALL BE IN SEQUENCE
ON ONE COLUMN AND THE EVEN-NUMBERED CIRCUITS ON THE OTHER COLUMN (E.G. 1,3,5...,2,4,6...).
EACH CIRCUIT SHALL BE IDENTIFIED AS TO THE USE AND ROOM NAME(S) OR AREA(S). THE CONTRACTOR
SHALL CONFIRM ROOM NAMES AND/OR ROOM NUMBERS WITH THE ARCHITECT PRIOR TO PROJECT
COMPLETION.
OS OS
WATER ROOM
3
TOILET
4
TOILET
5
WAITING
6
B
A
A
A
A
B
1
P3-15
P3-15 P3-15
P3-15 P3-15
P3-15
3 3
WATER ROOM
3
TOILET
4
TOILET
5
WAITING
6
GFI GFI
1
P2-21 P2-21
EF
10
ON ROOF
P1-24
4
IG IG IG
1
2
P2-9 P2-21
P2-21
P2-21 P2-21
P2-9 P2-9
P3-15 P3-15 P3-15
P3-15 P3-15
N
G
M
P1
P3 P2
TVSS
208Y/120V, 3PH, 4-WIRE
PADMOUNTED UTILITY
TRANSFORMER BY
CITY OF FORT COLLINS
X
29,500A
2 SETS(4#350, 3"C PVC)
X
BD BOILER BLOW DOWN
CD CONDENSATE DRAIN
CWS CONDENSER WATER SUPPLY
HCWS DUAL TEMPERATURE SUPPLY
HPS HIGH PRESSURE STEAM
HRS HEAT RECOVERY SUPPLY
HTWS HIGH TEMP WATER SUPPLY
HWS HOT WATER SUPPLY
LPS LOW PRESSURE STEAM
LS LOOP SUPPLY
MPS MEDIUM PRESSURE STEAM
PD PUMP DISCHARGE
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID
RS REFRIGERANT SUCTION
CHR CHILLED WATER RETURN
CWR CONDENSER WATER RETURN
HCWR DUAL TEMPERATURE RETURN
HPR HIGH PRESSURE STEAM CONDENSATE RETURN
HRR HEAT RECOVERY RETURN
HTWR HIGH TEMP WATER RETURN
HWR HOT WATER RETURN
LPR LOW PRESSURE STEAM CONDENSATE RETURN
LR LOOP RETURN
MPR MEDIUM PRESSURE STEAM CONDENSATE RETURN
AC ABOVE CEILING/AIR CONDITIONER
OA OUTDOOR AIR
ACC AIR COOLED CONDENSER
AF AIR FILTER
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AMS AIR MEASURING STATION
AS AIR SEPARATOR
AV AUTOMATIC AIR VENT
B BOILER
BAS BUILDING AUTOMATION SYSTEM
BDD BACKDRAFT DAMPER
BFC BELOW FINISHED CEILING
BFP BACKFLOW PREVENTION DEVICE
BJ BETWEEN JOISTS
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
BTUH BRITISH THERMAL UNITS PER HOUR
CA COMPRESSED AIR
CBS COUNTER BALANCED SHUTTER
CC COOLING COIL
CF CEILING / CIRCULATING FAN
CFM CUBIC FEET PER MINUTE
CH CHILLER
CHP CHILLED WATER PUMP
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CNV CONVECTOR
COND CONDENSATE
CP CONDENSATE PUMP
CRAC COMPUTER ROOM AIR CONDITIONER
CTTOWER COOLING
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONTROL VALVE
EXHAUST FAN SCHEDULE
MARK MANUFACTURER MODEL TYPE DRIVE SERVICE CFM TSP
(IN. W.C.)
SONES DAMPER
ROOF
OPENING
ELECTRICAL
DATA
REMARKS
L
(IN.)
W
(IN.)
HP/
WATTS
V/PH WT. (LBS.)
EF-10 COOK ACE-D 90C15DH DOWNBLAST DIRECT RESTROOMS 200 0.3 4.5 BD-12 13.5 13.5 1/8 115/1 42 1-3
NOTES: 1. PROVIDE FAN SPEED CONTROLLER.
2. PROVIDE DISCONNECT AT EXHAUST FAN.
3. FAN TO OPERATE CONTINUALLY.
AIR DEVICE SCHEDULE
MARK MANUFACTURER MODEL SERVICE STYLE
MAX.
N.C.
MAX.
AIR P.D.
(IN. W.C.)
MODULE
SIZE
FRAME FINISH MATERIAL REMARKS
S1 PRICE SDC SUPPLY CONE 25 0.022 12x12 LAY-IN WHITE ALUMINUM 1
E1 PRICE 80 EXHAUST EGGCRATE 25 0.013 12x12 LAY-IN WHITE ALUMINUM
NOTES: 1. PROVIDE BALANCE DAMPER.
WATER ROOM
3
TOILET
4
TOILET
5
WAITING
6
8x8
E1
100
8x8
E1
100
8x8
EF
10
2 8"ø
6"ø
S1
75
6"ø
S1
75
6"ø
S
50
PLUMBING PIPING MATERIAL SCHEDULE
SYSTEM TYPE MATERIAL SELECTION
DOM. CW ABOVE GRADE
ASTM B88 (ASTM B88M), TYPE L COPPER OR PEX
PIPING (ASTM F876 OR ASTM F877; 160 PSIG AT 73
DEGREES F) FOR ONE INCH PIPING AND SMALLER.
DOM. HW ABOVE GRADE
ASTM B88 (ASTM B88M), TYPE L COPPER OR PEX
PIPING (ASTM F876 OR ASTM F877; 160 PSIG AT 73
DEGREES F) FOR ONE INCH PIPING AND SMALLER.
DOM. HWC ABOVE GRADE
ASTM B88 (ASTM B88M), TYPE L COPPER OR PEX
PIPING (ASTM F876 OR ASTM F877; 160 PSIG AT 73
DEGREES F) FOR ONE INCH PIPING AND SMALLER.
SANITARY BELOW GRADE PIPING , WITHIN 5 FEET OF
BUILDING
CAST IRON, CISPI 301 HUBLESS OR HUB AND
SPIGOT PIPING; OR ASTM D2665 SCHEDULE 40 PVC
SANITARY ABOVE GRADE PIPING TO FIXTURES
CAST IRON, CISPI 301 HUBLESS OR HUB AND
SPIGOT PIPING; OR ASTM D2665 SCHEDULE 40 PVC
SANITARY VENT PIPING
CAST IRON, CISPI 301 HUBLESS OR HUB AND
SPIGOT PIPING; OR ASTM D2665 SCHEDULE 40 PVC
NOTES:
PLASTIC PIPING (PVC, CPVC, PEX, ETC.) IS NOT ALLOWED IN RETURN AIR PLENUMS UNLESS THE PIPING IS ASTM
E84 (25/50) RATED AND APPROVED BY ENGINEER FOR USE IN EACH INSTANCE. SUBMIT ALL PIPING TO BE USED
TO ENGINEER FOR REVIEW AND APPROVAL PRIOR TO PURCHASE.
PROVIDE ALL DOMESTIC SOLDER COPPER SYSTEMS WITH ASME B16.18 OR ASME B16.22 PIPE FITTINGS, SOLDER
AND FLUX (IF USED) THAT COMPLY WITH NSF 61 AND NSF 372 FOR MAXIMUM LEAD CONTENT FOR COPPER
PIPING INSTALLATIONS.
PROVIDE ALL MECHANICAL PRESSED SEALED DOMESTIC COPPER PIPING WITH DOUBLE PRESSED TYPE, NSF
61/NSF 372 APPROVED FITTINGS UTILIZING EDPM, NON-TOXIC RUBBER SEALING ELEMENTS WITH FOOD GRADE
RATED LUBRICANTS.
FOR DOMESTIC PEX PIPING INSTALLATIONS, PROVIDE WITH BRASS AND COPPER FITTINGS OR BRASS AND
ENGINEERED POLYMER (EP) FITTINGS THAT COMPLY WITH ASTM F1960 AND ASTM F1960, OR COLD EXPANSION
FITTINGS THAT CONFORM WITH ASTM
F1960.
PROVIDE ALL HUBLESS CAST IRON PIPING WITH CAST IRON FITTINGS AND EACH JOINT WITH CISPI 310, HEAVY
DUTY, STAINLESS STEEL CLAMP AND SHIELD ASSEMBLY WITH NEOPRENE GASKETS.
PROVIDE ALL HUB AND SPIGOT CAST IRON PIPING WITH ASTM C564, COMPRESSION TYPE, NEOPRENE GASKETS.
PROVIDE ASTM D2564 SOLVENT FOR ANY PVC DRAIN PIPING.
FOR ALL PIPING, PROVIDE BRACING IN ACCORDANCE WITH MSS SP 58 ATTACHED TO STRUCTURE OR TRAPEZE
HANGERS.
GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS. PROVIDE DIELECTRIC INSULATORS FOR ANY
DISSIMILAR METAL CONTACT BETWEEN PIPING, AND PIPING-AND-HANGERS IN ALL INSTANCES. PROVIDE
CLEARANCE FROM HANGERS, FROM STRUCTURE, AND OTHER EQUIPMENT FOR INSTALLATION OF THE
INSULATION AND TO PROVIDE ACCESS TO VALVES, FITTINGS AND OTHER APPURTENANCES. PROVIDE PEX
PIPING WITH MANUFACTURER APPROVED, PREFABRICATED HANGERS AND SUPPORTS TO ALLOW FOR PIPING
SUPPORTS AND CONFIGUREATIONS SAME/SIMILAR TO COPPER PIPING SUPPORT REQUIREMENTS OF A SIMILAR
SIZE.
FOR ALL BELOW GRADE METALLIC PIPING, LAP AND DOUBLE WRAP BELOW GRADE PIPING AND PIPING
THROUGH GRADE
PENETRATIONS CONTINUOUSLY TO APPROXIMATELY THREE INCHES ABOVE GRADE WITH PROTECTIVE TAPE
AND/OR PLASTIC WRAPPING TO PREVENT DAMAGE AND CORROSION. COORDINATE EXACT REQUIREMENTS
WITH LOCAL AHJ PRIOR TO INSTALLATION.
IN ALL CASES REFER TO PLUMBING SPECIFICATIONS.
COMMON REQUIREMENTS
GENERAL NOTES
A. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISCONNECTION AND
WATER ROOM
TOILET 3
4
TOILET
5
WAITING
6
3/4"HW
1/2"HWC
1 1/2"CW
1 1/2"CW
1/2"HWC
3/4"HW
3/4"CW
1"CW 1"CW
3/4"HW
3/4"CW
3/4"HW
1/2"HWC
1
4
7 6 6 7 1
2
3
9
3/4"HW
1/2"HWC
1 1/2"CW
4"FCO
4"W 4"FCOW 4"
4"W
1 1/2"CW
1/2"HWC
3/4"HW
3/4"CW
2"V
(E) VENT PIPING SHOWN HERE
IS BELOW SLAB BEFORE
RISING IN WALL TO OVERHEAD.
TO 3"VTR
FROM (E)
WATER ENTRY
3
5
4
4
SAW CUT IN THIS
WORK AREA AS
REQUIRED FOR
NEW FIXTURE
INSTALLATIONS.
WATER ROOM
3
TOILET
4
TOILET
5
WAITING
6
4"FCO
4"W 4"FCOW 4"
4"W
4"W
2"V
2"V
2"V
1 1/2"V
2"V
1 1/2"W
4"W
1 1/2"W
5
4
3
8 8
2"V
HOT
WATER
SUPPLY
TYPICAL QUATER TURN STOP
COLD WATER
SUPPLY
TW
TYPICAL LAVATORY
(SELF-RIMMING OR
WALL HUNG)
TMV (SEE SCHEDULE)
SENSOR FAUCET
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
ISSUE:
# DATE: DESCRIPTION:
NOT FOR CONSTRUCTION
DESIGNED:
4/7/2020 10:16:43 AM
P1.1
DEMO AND NEW
FLOORPLAN, NOTES,
AND DETAILS
BAJ
CRF
0200100.04
Downtown Transit
Center - Restroom
Upgrades
City of Fort Collins
250 N. Mason St, Fort Collins, CO
04.08.2020
JMB
90% CD
I. ENSURE BUILDING SUPPLY PRESSURE IS SET NO HIGHER THAN 80 PSI MAX.
H. ALL NEW WASTE PIPING SHOWN IS BELOW THE FLOOR OF THE INDICATED LEVEL.
G. GROUP ALL DOMESTIC PIPING. PIPE LABELS ARE TO BE READ FROM LEFT TO RIGHT
OR TOP TO BOTTOM.
F. ALL WATER PIPING SHALL BE INSULATED PER THE IECC AND PVC-JACKETED.
E. ALL VALVES SHOWN ARE TO BE LINE SIZED AND NORMALLY OPEN UNLESS
OTHERWISE INDICATED ON THE DRAWINGS.
D. ALL NEW DOMESTIC AND VENT PIPING SHALL BE MOUNTED AS HIGH AS POSSIBLE IN
THE OVERHEAD SPACE. REFERENCE STRUCTURAL DRAWINGS.
C. INSTALL ALL FIXTURES, APPURTENANCES, VALVES, AND EQUIPMENT AS PER THE
MANUFACTURERS RECOMMENDATIONS.
B. SUBMIT ALL PIPING, FITTINGS, HANGERS, FIXTURES AND ASSOCIATED
APPURTENANCES TO BE USED FOR THIS PROJECT TO ENGINEER FOR REVIEW AND
APPROVAL PRIOR TO PURCHASE.
A. REFER TO P0.1 FOR ADDITIONAL GENERAL NOTES.
GENERAL NOTES
0 2 4 8
NORTH
TRUE
SCALE: 1/4" = 1'-0"
2
DOMESTIC PLUMBING PLAN
KEYNOTES #
1 ROUTE HOT WATER PIPING DOWN IN WALL HERE TO BEHIND THE STOP VALVES
THAT SERVE THE LAVATORIES. CONNECT HOT WATER CIRCULATION PIPING JUST
DOWNSTREAM OF THIS POINT AND BACK UP IN WALL TO OVERHEAD AS SHOWN.
2 PROVIDE BALANCE VALVE FOR APPROXIMATELY 0.5 GPM AND 1 PSI OF PRESSURE
DROP. EXISTING BUILDING HOT WATER CIRCULATION SYSTEM FOR A FULL
FUNCTIONING HOT WATER SYSTEM FOR THE ENTIRE BUILDING.
3 TO/FROM CONFERENCE AND BREAKROOM.
4 TO/FROM RESTROOMS, WORK ROOM, AND JANITORS CLOSET.
5 TO 4" BUILDING DRAIN. I.E. AT BLDG EDGE ~4.0 FT BFF.
6 ADA COMPLIANT, ELONGATED, FLOOR MOUNTED, PRESSURE ASSISTED FLUSH
TANK WATER CLOSET. MUST BE WATER SENSE CERTIFIED AND FLUSH ON 1.1 GPF.
KOHLER: HIGHLINE CLASSIC COMFORT HEIGHT. (MODEL: K-3519-T) PROVIDE WITH
OPEN FRONT SEAT, LESS COVER, WITH STAINLESS STEEL, SELF SUSTAINING
CHECK HINGE.PROVIDE WITH SLOAN/FLUSHMATE INTELLI-FLUSH ON WALL SENSOR
TYPE ADAPTER IN WHITE. (MODEL: K-100100) COORDINATE WITH SUPPLIER TO
ENSURE ACCURATE ADAPTER IS SUPPLIED. PROVIDE PER MANUFACTURERS
RECOMMENDATIONS AND COORDINATE MOUNTING HEIGHT TO MATCH
SAME/SIMILAR TO EXISTING RESTROOM CONFIGURATIONS.
7 ADA COMPLIANT, WALL MOUNTED, WHITE VITREOUS CHINA LAVATORY WITH 20
INCH X 18 INCH BASIN. PROVIDE BASIN WITH 3 HOLE DRILLINGS ON 4 INCH
CENTERS, 4 INCH BACK SPLASH, OVERFLOW, AND CONCEALED ARM SUPPORTS
FOR IN WALL LAVATORY CARRIER. AMERICAN STANDARD: LUCERNE. PROVIDE WITH
A SENSOR ACTIVATED, BATTERY POWERED, CHROME PLATED CONVENTIONAL
SPOUT FAUCET WITH 0.5 GPM VANDAL RESISTANT AERATOR. DELTA:
591LF-LGHGMHDF PROVIDE TRIM WITH: MINIMUM 17-GAUGE 1-1/4 INCH OFFSET
GRID STRAINER AND P-TRAP WITH INTEGRAL CLEANOUT; QUARTER TURN, CHROME
PLATED SOLID BRASS ANGLE STOPS AND WITH FLEXIBLE CONNECTORS AND
CHROME PLATED WALL ESCUTCHEONS; WITH ADA TRAP, STOP, AND SUPPLY
PROTECTORS. PROVIDE WITH THERMOSTATIC MIXING VALVES OF LEAD FREE
CONSTRUCTION FOR SINGLE FIXTURE APPLICATIONS ALLOWING DOWN TO 0.25
GPM AND SET OUTLET TO 105 DEG F MAX. WATTS: LFUSG-B.
8 2 INCH FLOOR DRAIN. PROVIDE WITH NICKEL-BRONZE FINISH AND HEEL-PROOF,
ROUND GRATING. JAY R. SMITH: 2005. PROVIDE WITH INSERTED, ELASTOMERIC
TRAP SEAL THAT IS ASSE 10702 COMPLIANT.
9 GROUP NEW RESTROOM(S) VALVES TOGETHER. FIELD COORDINATE EXACT
PLACEMENTS FOR ACCESSIBLE LOCATION(S) FOR EASE OF MAINTENANCE.
PROVIDE LABEL(S) WITH VALVING TO INDICATE AREA SERVED.
SCALE: 1/4" = 1'-0"
1
PLUMBING DEMOLITION PLAN KEY PLAN
SCALE: 1/4" = 1'-0"
3
DRAIN WASTE AND VENT PLAN
D. EXISTING CONDITIONS ARE DRAWN TO MOST CURRENT INFORMATION AVAILABLE TO
ENGINEER AND TO ILLUSTRATE DIAGRAMMATIC INTENT. FIELD VERIFY EXISTING
PIPING CONDITIONS PRIOR TO START OF WORK. COORDINATE IN WRITING WITH
ENGINEER OF ANY DEVIATIONS OBSERVED.
C. ALL EXISTING DOMESTIC PIPING SHOWN IS IN THE OVERHEAD SPACE OF THE
INDICATED LEVEL.
B. ALL EXISTING WASTE PIPING SHOWN IS BELOW THE FLOOR OF THE INDICATED LEVEL.
A. REFER TO P0.1 FOR ADDITIONAL GENERAL DEMOLITION NOTES.
GENERAL DEMOLITION NOTES
D. ALL FIRE PROTECTION RELATED EQUIPMENT AND PIPING WHICH IS REMOVED FROM
THE BUILDING IS TO BE TAKEN OFFSITE AND DISPOSED OF LEGALLY.
C. COORDINATE DEMOLITION OF FIRE PROTECTION PIPING WITH OTHER PIPING WHICH IS
NOT TO BE REMOVED. PROTECT OTHER PIPING WHICH IS NOT TO BE REMOVED FROM
DAMAGE, DIRT, AND DEBRIS.
B. COORDINATE WITH OWNER FOR ANY SHUTDOWNS OR PLANNED INTERRUPTIONS OF
THE FIRE PROTECTION SERVICE. THE CONTRACTOR SHALL GIVE THE OWNER THREE
(3) DAYS NOTICE PRIOR TO THE PLANNED SHUTDOWN OR INTERRUPTION.
A. THE CONTRACTOR IS TO FIELD VERIFY THE EXACT LOCATIONS OF EXISTING FIRE
PROTECTION LINES AND EQUIPMENT INCLUDING RISERS AND VALVES PRIOR TO THE
START OF WORK.
FIRE PROTECTION GENERAL DEMOLITION
NOTES
F. CENTER ALL SPRINKLER HEADS IN WORK AREA IN TWO DIRECTIONS WHEN LOCATED
IN CEILING SPACES WITH CEILING TILES AND SYMMETRICALLY WITH OTHER CEILING
DEVICES IN GYP CEILINGS. ARCHITECT SHALL HAVE FINAL APPROVAL OF
SYMMETRICAL LAYOUT PRIOR TO INSTALLATION.
E. PROVIDE SERVICED AREAS WITH NEW SPRINKLER HEADS AND PIPING TO MATCH
EXISTING AS REQUIRED. PROVIDE A NEW SPARE HEAD FOR MAINTENANCE
PURPOSES.
D. ADJUST SPRINKLER HEAD LOCATIONS AND TYPES AS REQUIRED FOR THE NEW SPACE
LAYOUTS. REFER TO ARCHITECTURAL DRAWINGS FOR SPACE CATEGORY
CLASSIFICATIONS AND REFLECTED CEILING PLANS FOR COORDINATION.
C. PROVIDE AS-BUILT SHOP DRAWING UPON COMPLETION OF INSTALLATION.
B. PRESSURE TEST SYSTEM UPON COMPLETION OF INSTALLATION IN ACCORDANCE
WITH 2013 NFPA 13. REPAIR LEAKS IN PIPING UNDER THIS CONTRACT.
A. PROVIDE RENOVATED FIRE PROTECTION SYSTEM TO PROVIDE FIRE PROTECTION
COVERAGE OF RENOVATION AREAS IN ACCORDANCE 2013 NFPA 13, LOCAL CODES
AND ALL AHJ DESIGN GUIDELINES AND INSTALLATION REQUIREMENTS.
FIRE PROTECTION GENERAL NOTES
SECTION- BASIC PLUMBING GENERAL REQUIREMENTS
PART 1- GENERAL
SUMMARY
SECTION SPECIFIES THE BASIC REQUIREMENTS FOR PLUMBING INSTALLATIONS AND INCLUDES
REQUIREMENTS COMMON TO MORE THAN ONE SECTION OF THE SPECIFICATIONS.
GENERAL REFERENCES
ALL OF THE DRAWINGS AND SPECIFICATIONS ARE CONSIDERED A PART OF THE CONTRACT
DOCUMENTS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR SEARCHING ALL CONTRACT DOCUMENTS TO
DETERMINE THE SCOPE OF WORK REQUIRED IN FINAL CONNECTIONS TO EQUIPMENT PROVIDED BY
OTHER CONTRACTS OR CONTRACTORS. IT IS THE INTENT OF THE DRAWINGS TO PROVIDE AS MUCH
INFORMATION AS POSSIBLE ON EQUIPMENT PROVIDED BY OTHERS. HOWEVER, THE EXTENT OF
FINAL CONNECTIONS AND TYPE OF FINAL CONNECTIONS SHALL BE DETERMINED BY THE ACTUAL
EQUIPMENT SUPPLIED BY OTHERS. THIS CONTRACTOR SHALL INCLUDE IN HIS BASE BID,
REASONABLE COST FOR THE INSTALLATION OF EQUIPMENT PROVIDED BY OTHERS. HE SHALL NOT
BE AWARDED EXTRA COSTS AFTER THE CONTRACT IS AWARDED UNLESS THE EQUIPMENT SO
INSTALLED IS NOT SHOWN ON ANY OF THE CONTRACT DOCUMENTS.
WORK INCLUDED UNDER THIS DIVISION SHALL CONSIST OF FURNISHING ALL MATERIALS, SUPPLIES,
EQUIPMENT, TOOLS, INSURANCE, TRANSPORTATION AND FACILITIES, AND PERFORMING ALL LABOR
AND SERVICES NECESSARY FOR COMPLETE INSTALLATION OF THE NEW PLUMBING SYSTEM(S).
DRAWINGS
DRAWINGS ARE DIAGRAMMATIC, INDICATING ONLY APPROXIMATE LOCATIONS OF SERVICES,
FIXTURES, APPARATUS, AND PIPING UNLESS NOTED OTHERWISE, AND ARE NOT TO BE SCALED.
ACTUAL INSTALLATION MUST CONFORM TO ACTUAL BUILDING CONDITIONS AND VERIFIED IN THE
FIELD. THE ARCHITECT/ ENGINEER RESERVES THE RIGHT TO EFFECT REASONABLE CHANGES IN THE
LOCATION OF EQUIPMENT UP TO THE TIME OF ROUGH-IN WITHOUT ADDITIONAL COST TO THE
OWNER. ANY AND ALL CHANGES SHALL BE APPROVED BY THE ARCHITECT/ ENGINEER. MAINTAIN
MANUFACTURERS RECOMMENDED CLEARANCES AROUND ALL EQUIPMENT.
THE DECISION OF THE ARCHITECT/ ENGINEER AS TO THE TRUE INTENT AND MEANING OF THE PLANS
AND SPECIFICATIONS SHALL BE FINAL AND BINDING UPON BOTH PARTIES TO THE CONTRACT. ITEMS
OMITTED FROM THE DRAWINGS BUT SPECIFIED, OR ITEMS CALLED FOR ON THE DRAWINGS BUT
OMITTED FROM THE SPECIFICATIONS, SHALL BE CONSIDERED AS APPEARING IN BOTH. WHERE A
CONFLICT OCCURS BETWEEN SPECIFICATIONS AND DRAWINGS, THE MOST EXPENSIVE ITEM WILL
TAKE PRECEDENCE. THE CONFLICT WILL THEN BE RESOLVED DURING CONSTRUCTION AND A CREDIT
ISSUED FOR A LESS COSTLY SOLUTION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL PLUMBING PIPING, AND
TO CONFORM TO ACTUAL BUILDING STRUCTURAL CONDITIONS.
ITEMS OMITTED FROM DRAWINGS AND/ OR SPECIFICATIONS BUT REQUIRED FOR PROPER
OPERATION OF EQUIPMENT OR FIXTURES BY MANUFACTURER SHALL BE CONSIDERED AS PART OF
THE CONTRACT DOCUMENTS. ITEMS AS STATED ABOVE WHICH ARE NECESSARY TO COMPLY WITH
THE INTENT OF THE CONTRACT DOCUMENTS SHALL BE CONSIDERED AS PART OF THE CONTRACT
REQUIREMENTS.
REGULATORY REQUIREMENTS
PLUMBING TO CONFORM TO THE STATE OF COLORADO STATE PLUMBING CODE, INTERNATIONAL
PLUMBING CODE, AND LOCAL, COUNTY, AND CITY CODES.
SECURE AND PAY FOR ALL PERMITS AND CERTIFICATIONS OF INSPECTIONS INCIDENTAL TO THIS
WORK REQUIRED BY FOREGOING AUTHORITIES. BE RESPONSIBLE FOR PAYMENTS TO ALL PUBLIC
UTILITIES FOR WORK PERFORMED BY THEM IN CONNECTION WITH THE PROVISION OF SERVICE
CONNECTION REQUIRED.
DELIVER ALL CERTIFICATES TO ARCHITECT/ ENGINEER IN DUPLICATE.
PART 2- PRODUCTS (REFER TO PLUMBING SCHEDULES)
PART 3- EXECUTION
OPERATIONS MANUAL
THIS CONTRACTOR SHALL FURNISH COMPETENT PERSONNEL TO INSTRUCT THE OWNER'S
OPERATING PERSONNEL IN THE PROPER OPERATION OF EACH PIECE OF EQUIPMENT AND FIXTURES.
PRIOR TO FINAL PAYMENT DEMONSTRATE TO THE OWNER'S SATISFACTION THE PROPER OPERATION
OF EACH AND ALL SYSTEMS, INSTRUCTING IN OPERATION AND MAINTENANCE OF PLUMBING
FIXTURES AND EQUIPMENT.
GENERAL PIPING AND VALVES
ALL PIPING SHALL BE INSTALLED PARALLEL WITH, OR AT RIGHT ANGLES TO, THE BUILDING WALLS.
ALL VERTICAL RISERS SHALL BE INSTALLED PLUMB AND STRAIGHT.
ALL PIPING SHALL BE INSTALLED WITH A PITCH IN THE DIRECTION OF FLOW OF NOT LESS THAN ONE
INCH IN FORTY FEET, EXCEPT AS OTHERWISE SHOWN. IT MUST BE POSSIBLE TO DRAIN EVERY
PORTION OF THE PIPING SYSTEM. DRAINS SHALL HAVE HOSE THREAD ENDS.
ANY PIPE RESTING ON OR COMING IN CONTACT WITH BUILDING STRUCTURE OR SUPPLEMENTAL
SUPPORTS SHALL BE INSULATED AT THAT POINT TO PREVENT TELEGRAPHING OF SOUND OR
VIBRATION.
ALL PLUMBING PIPING SHALL BE RIGIDLY SUPPORTED AND SHALL NOT BE LOOSE OR SHAKY. COPPER
WATER PIPING JOINTS SHALL BE MADE WITH THE SCHEDULED FITTINGS. SURFACE TO BE SOLDERED
SHALL BE CLEANED BRIGHT, PROPERLY FLUXED AND MADE WITH SILVER SOLDER OF NOT LESS
THAN 95-5. JOINTS BETWEEN COPPER PIPE TO SCREWED PIPE JOINTS SHALL BE MADE BY USE OF A
BRASS FITTING.
CLEAN- UP
AT ALL TIMES KEEP PREMISES AND BUILDING IN NEAT ORDERLY CONDITION, FOLLOW EXPLICITLY
ANY INSTRUCTIONS OF CONSTRUCTION MANAGER AND ARCHITECT/ ENGINEER IN REGARD TO
STORING OF MATERIALS, PROTECTIVE MEASURES, CLEANING- UP OF DEBRIS, ETC. UPON
COMPLETION OF THE WORK THE CONTRACTOR SHALL THOROUGHLY CLEAN ALL FIXTURES, FAUCET
AERATORS, FLUSH VALVE DIAPHRAGMS, EQUIPMENT, PACK ALL VALVES REMOVING ALL DIRT,
GREASE AND OIL.
FIRE AND SOUND STOPPING
PIPE SLEEVES SHALL BE SIZED TO ALLOW FOR PROPER ANNULAR SPACE BETWEEN SLEEVE AND
PIPE OR INSULATION. SEAL THE ANNULAR SPACE WITH A FIRE RETARDANT CAULK OR PUTTY ON ALL
WALLS USING UL APPROVED METHOD AS RECOMMENDED BY THE SEALANT MANUFACTURER. THE
SIZE OF THE ANNULAR SPACE WILL VARY DEPENDENT ON THE SEALANT APPLICATION TECHNIQUE
WITH THE SEALANT MANUFACTURER. FIRE AND SOUND STOPPING SEALER SHALL BE 3M FIRE
BARRIER CAULK CP25 OR PUTTY 303, THOMAS & BETTS FLAME-SAFE FIRE STOP COMPOUND OR
NELSON FLAMESEAL PUTTY.
SECTION- ESCUTCHEONS FOR PLUMBING PIPING
PART 1- GENERAL
SUMMARY
ESCUTCHEONS FOR PIPING AT CEILING, FLOOR AND WALL PENETRATIONS.
PART 2 - PRODUCTS
ESCUTCHEONS
ONE-PIECE, CAST BRASS TYPE, WITH POLISHED, CHROME-PLATED AND ROUGH-BRASS FINISH AND
SETSCREW FASTENER.
ONE-PIECE, DEEP-PATTERN TYPE: DEEP-DRAWN, BOX-SHAPED BRASS WITH CHROME-PLATED FINISH
AND SPRING-CLIP FASTENERS.
ONE-PIECE, STAMPED-STEEL TYPE: WITH CHROME-PLATED FINISH AND SPRING-CLIP FASTENERS.
PART 3 - EXECUTION
INSTALLATION
INSTALL ESCUTCHEONS FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FINISHED FLOORS.
INSTALL ESCUTCHEONS WITH ID TO CLOSELY FIT AROUND PIPE, TUBE, AND INSULATION OF PIPING
AND WITH OD THAT COMPLETELY COVERS OPENING.
FIELD QUALITY CONTROL
REPLACE BROKEN AND DAMAGED ESCUTCHEONS AND FLOOR PLATES USING NEW MATERIALS.
PART 3 - EXECUTION (NOT APPLICABLE)
SECTION- GENERAL-DUTY VALVES FOR PLUMBING PIPING
PART 1- GENERAL
SUMMARY
SECTION INCLUDES GENERAL DUTY VALVES COMMON TO MULTIPLE PLUMBING SYSTEMS.
ACTION SUBMITTALS
PRODUCT DATA: FOR EACH TYPE OF VALVE INDICATED.
QUALITY ASSURANCE
ASME COMPLIANCE:
ASME B16:10 AND ASME B16:34 FOR FERROUS VALVE DIMENSIONS AND DESIGN CRITERIA.
ASME B31.1 FOR POWER PIPING VALVES.
ASME B31.9 FOR BUILDING SERVICES PIPING VALVES.
NSF COMPLIANCE: NSF 61 FOR VALVE MATERIALS FOR POTABLE-WATER SERVICE.
PART 2 - PRODUCTS
GENERAL REQUIREMENTS FOR VALVES
VALVE PRESSURE AND TEMPURATURE RATINGS: NOT LESS THAN INDICATED AND AS REQUIRED FOR
SYSTEM PRESSURES AND TEMPERATURES.
BRONZE BALL VALVES
TWO-PIECE, FULL-PORT, BRONZE BALL VALVES WITH BRONZE TRIM.
DESCRIPTION:
STANDARD: MSS SP-110, SWP RATING: 150 PSIG; BODY DESIGN: TWO PIECE; BODY MATERIAL:
BRONZE.
DESCRIPTION:
BRONZE SWING CHECK VALVES
CLASS 150, BRONZE SWING CHECK VALVES WITH BRONZE DISC:
DESCRIPTION:
STANDARD: MSS SP-80, TYPE 3, BODY DESIGN: HORIZONTAL FLOW, BODY MATERIAL: ASTM B 62,
BRONZE,
ENDS: THREADED, DISC: BRONZE.
VALVE INSTALLATION
LOCATE VALVES FOR EASY ACCESS AND PROVIDE SEPARATE SUPPORT WHERE NECESSARY.
IF VALVES WITH SPECIFIED SWP CLASSES OR CWP RATINGS ARE NOT AVAILABLE, THE SAME TYPES
OF VALVES WITH HIGHER SWP CLASSES OR CWP RATINGS MY BE SUBSTITUTED.
DOMESTIC, HOT-AND COLD-WATER VALVE SCHEDULE
PIPE NPS2 AND SMALLER:
BRONZE VALVES: MAY BE PROVIDED WITH SOLDER-JOINT ENDS INSTEAD OF THREADED ENDS.
BALL VALVES: TWO PIECE, FULL PORT, BRONZE WITH BRONZE DISC.
PERFORMANCE REQUIREMENTS
DELEGATED DESIGN: DESIGN TRAPEZE PIPE HANGERS AND EQUIPMENT SUPPORTS, INCLUDING
COMPREHENSIVE ENGINEERING ANALYSIS BY A QUALIFIED PROFESSIONAL ENGINEER, USING
PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED.
ACTION SUBMITTALS
PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
PART 2 - PRODUCTS
METAL PIPE HANGERS AND SUPPORTS
CARBON-STEEL PIPE HANGERS AND SUPPORTS:
DESCRIPTION: MSS SP-58, TYPES 1 THROUGH 58, FACTORY-FABRICATED COMPONENTS.
GALVANIZED METALLIC COATINGS: PRE-GALVANIZED OR HOT DIPPED. HANGER RODS: CONTINUOUS-
THREAD ROD, AND WASHER MADE OF CARBON STEEL.
COPPER PIPE HANGERS:
DESCRIPTION: MSS SP-58, TYPES 1 THROUGH 58, COPPER-COATED-STEEL, FACTORY-FABRICATED
COMPONENTS. HANGER RODS: CONTINUOUS-THREAD ROD, NUTS, AND WASHER MADE OF COPPER-
COATED STEEL.
TRAPEZE PIPE HANGERS
DESCRIPTION: MSS SP-69, TYPE 59, SHOP-OR FIELD-FABRICATED PIPE-SUPPORT ASSEMBLY MADE
FROM STRUCTURAL CARBON-STEEL SHAPES WITH MSS SP-58 CARBON-STEEL HANGER RODS, NUTS,
SADDLES, AND U-BOLTS.
FASTENER SYSTEMS
MECHANICAL-EXPANSION ANCHORS: INSERT-WEDGE TYPE ZINC COATED, STAINLESS-STEEL
ANCHORS, FOR USE IN HARDENED PORTLAND CEMENT CONCRETE; WITH PULL-OUT, TENSION, AND
SHEAR CAPACITIES APPROPRIATE FOR SUPPORTED LOADS AND BUILDING MATERIALS WHERE USED.
PIPE POSITIONING SYSTEMS
DESCRIPTION: IAPMO PS 42, POSITIONING SYSTEM OF METAL BRACKETS, CLIPS AND STRAPS FOR
POSITIONING PIPING IN PIPE SPACES, FOR PLUMBING FIXTURES IN COMMERCIAL APPLICATIONS.
SECTION- IDENTIFCATION FOR PLUMBING PIPING AND EQUIPMENT
PART 1- GENERAL
SUMMARY
SECTION INCLUDES LABELS, STENCILS, AND VALVE TAGS COMMON TO PLUMBING SYSTEMS.
ACTION SUBMITTALS
PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
PART 2 – PRODUCTS
PIPE LABELS
GENERAL REQUIREMENTS FOR MANUFACTURED PIPE LABELS: PREPRINTED, COLOR-CODED, WITH
LETTERING INDICATED SERVICE, AND SHOWING FLOW DIRECTION.
SELF-ADHESIVE PIPE LABELS: PRINTED PLASTIC WITH CONTACT-TYPE, PERMANENT-ADHESIVE
BACKING.
PIPE LABEL CONTENTS: INCLUDE IDENTIFICATION OF PIPING SERVICE USING SAME DESIGNATIONS
OR ABBREVIATIONS AS USED ON DRAWINGS; ALSO INCLUDE PIPE SIZE AND AN ARROW INDICATING
FLOW DIRECTION.
PART 3 – EXECUTION
PIPE LABEL INSTALLATION
PIPE LABEL LOCATIONS: LOCATE PIPE LABELS WHERE PIPING IS EXPOSED OR ABOVE ACCESSIBLE
CEILINGS IN FINISHED SPACES; MACHINE ROOMS; ACCESSIBLE MAINTENANCE SPACES SUCH AS
SHAFTS, TUNNELS, AND PLENUMS.
SECTION- PLUMBING PIPING INSULATION
PART 1- GENERAL
SUMMARY
SECTION INCLUDES INSULATION, JACKETS AND INSULATION ACCESSORIES FOR PLUMBING PIPING TO
PREVENT HEAT LOSS IN ACCORDANCE WITH THE LATEST ENERGY STANDARDS.
ACTION SUBMITTALS
PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
QUALITY ASSURANCE
SURFACE-BURNING CHARACTERISTICS: FOR INSULATION AND RELATED MATERIALS, AS
DETERMINED BY TESTING IDENTICAL PRODUCTS ACCORDING TO ASTM E 84 BY A TESTING AGENCY
ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. FACTORY LABEL INSULATION AND JACKET
MATERIALS AND
ADHESIVE, MASTIC, TAPES, AND CEMENT MATERIAL CONTAINERS, WITH APPROPRIATE MARKINGS OF
APPLICABLE TESTING AGENCY.
INSULATION INSTALLED INDOORS: FLAME-SPREAD INDEX OF 25 OR LESS, AND SMOKE-DEVELOPED
INDEX OF 50 OR LESS. COMPLY WITH THE FOLLOWING APPLICABLE STANDARDS AND OTHER
REQUIREMENTS SPECIFIED FOR MISCELLANEOUS COMPONENTS:
SUPPLY AND DRAIN PROTECTIVE SHIELDING GUARDS: ICC A117.1.
PART 2 – PRODUCTS
INSULATION MATERIALS
COMPLY WITH REQUIREMENTS IN “PIPING INSULATION SCHEDULE, GENERAL,” “INDOOR PIPING
INSULATION SCHEDULE,” ARTICLES FOR WHERE INSULATING MATERIALS SHALL BE APPLIED.
PRODUCTS SHALL NOT CONTAIN ASBESTOS, LEAD, MERCURY, OR MERCURY COMPOUND.
FLEXIBLE ELASTOMERIC INSULATION: CLOSED-CELL, SPONGE-OR EXPANDED-RUBBER MATERIALS.
COMPLY WITH ASTM C534, TYPE I FOR TUBULAR MATERIALS.
MINERIAL-FIBER, PREFORMED PIPE INSULATION: TYPE I, 850 DEG F MAXIMUM SERVICE
TEMPERATURE MATERIALS: MINERAL OR GLASS FIBERS BONDED WITH A THERMOSETTING RESIN.
COMPLY WITH ASTM C547 AND ASTM C795, TYPE I, GRADE A, WITH FACTORY-APPLIED ASJ. FACTORY-
APPLIED JACKET. SHALL HAVE A ‘K’ VALUE OF 0.24 AT 75 DEGREES F. AS PER ASTM C177.
ADHESIVES
FLEXIBLE ELASTOMERIC AND POLYOLEFIN ADHESIVE: COMPLY WITH MIL-A-24179A, TYPE II, CLASS I.
MINERAL-FIBER ADHESIVE: COMPLY WITH MIL-A-3316C, CLASS 2, GRADE A.
ASJ ADHESIVE, AND FSK JACKET ADHESIVE: COMPLY WITH MIL-A-3316C, CLASS 2, GRADE A FOR
BONDING INSULATION JACKET LAP SEAMS AND JOINTS.
SEALANTS
JOINT SEALANTS:
MATERIALS SHALL BE COMPATIBLE WITH INSULATION MATERIALS, JACKETS, AND SUBSTRATES.
PERMANENTLY FLEXIBLE, ELASTOMERIC SEALANT. SERVICE TEMPERATURE RANGE: MINUS 100 TO
PLUS 300 DEG F.
FACTORY-APPLIED JACKETS
INSULATION SYSTEM SCHEDULES INDICATE FACTORY-APPLIED JACKETS ON VARIOUS APPLICATIONS.
WHEN FACTORY-APPLIED JACKETS ARE INDICATED, COMPLY WITH THE FOLLOWING:
ASJ-SSL: ASJ WITH SELF-SEALING, PRESSURE-SENSITIVE, ACRYLIC-BASED ADHESIVE COVERED BY A
REMOVABLE PROTECTIVE STRIP; COMPLYING WITH ASTM C 1136, TYPE I.
TAPES
ASJ TAPE: WHITE VAPOR-RETARDER TAPE MATCHING FACTORY-APPLIED JACKET WITH ACRYLIC
ADHESIVE, COMPLYING WITH ASTM C 1136.
SECUREMENTS
STAPLES: OUTWARD-CLINCHING INSULATION STAPLES, NOMINAL ¾ INCH-WIDE, STAINLESS STEEL OR
MONEL.
PROTECTIVE SHIELDING GUARDS
PROTECTIVE SHIELDING PIPE COVERS. DESCRIPTION: MANUFACTURED PLASTIC WRAPS FOR
COVERING PLUMBING FIXTURE HOT-AND COLD-WATER SUPPLIES AND TRAP AND DRAIN PIPING.
COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS.
PART 3 – EXECUTION
GENERAL INSTALLATION REQUIREMENTS
INSTALL INSULATION MATERIALS, ACCESSORIES, AND FINISHES WITH SMOOTH, STRAIGHT, AND EVEN
SURFACES; FREE OF VOIDS THROUGHOUT THE LENGTH OF PIPING INCLUDING FITTINGS, VALVES,
AND SPECIALTIES. INSTALL INSULATION MATERIALS, FORMS, VAPOR BARRIERS OR RETARDERS,
JACKETS, AND THICKNESSES REQUIRED FOR EACH ITEM OF PIPE SYSTEM AS SPECIFIED IN
INSULATION SYSTEM SCHEDULES. INSTALL ACCESSORIES COMPATIBLE WITH INSULATION
MATERIALS AND SUITABLE FOR THE SERVICE. INSTALL ACCESSORIES THAT DO NOT CORRODE,
SOFTEN, OR OTHERWISE ATTACK INSULATION OR JACKET IN EITHER WET OR DRY STATE.
INSULATION INSTALLATION AT INTERIOR WALL AND PARTITION PENETRATIONS (THAT ARE NOT FIRE
RATED): INSTALL INSULATION CONTINUOUSLY THROUGH WALLS AND PARTITIONS.
INSULATION INSTALLATION AT FIRE-RATED WALL AND PARTITION PENETRATIONS:
INSTALL INSULATION CONTINUOUSLY THROUGH PENETRATIONS OF FIRE-RATED WALLS AND
PARTITIONS.
GENERAL PIPE INSULATION INSTALLATION
INSULATION INSTALLATION OF STRAIGHT PIPES AND TUBES:
SECURE EACH LAYER OF PREFORMED PIPE INSULATION TO PIPE WITH WIRE OR BANDS AND TIGHTEN
BANDS WITHOUT DEFORMING INSULATION MATERIALS.
FOR INSULATION WITH FACTORY-APPLIED JACKETS ON BELOW-AMBIENT SURFACES, DO NOT STAPLE
LONGITUDINAL TABS. INSTEAD, SECURE TABS WITH ADDITIONAL ADHESIVE AS RECOMMENDED BY
INSULATION MATERIALS. FOR INSULATION WITH FACTORY-APPLIED JACKETS ON BELOW-AMBIENT
SURFACES, DO NOT STAPLE LONGITUDINAL TABS. INSTEAD, SECURE TABS WITH ADDITIONAL
ADHESIVE AS RECOMMENDED BY INSULATION MATERIAL MANUFACTURER AND SEAL WITH VAPOR-
BARRIER MASTIC AND FLASHING SEALANT.
INSULATION INSTALLATION ON PIPE FITTINGS AND ELBOWS:
INSTALL PREFORMED SECTIONS OF SAME MATERIAL AS STRAIGHT SEGMENTS OF PIPE INSULATION
WHEN AVAILABLE. WHEN PREFORMED INSULATION ELBOWS AND FITTINGS ARE NOT AVAILABLE,
INSTALL MITERED SECTIONS OF PIPE INSULATION, TO A THICKNESS EQUAL TO ADJOINING PIPE
INSULATION. SECURE INSULATION MATERIALS WITH WIRE OR BANDS.
DIVISION 22 0000 SPECIFICATIONS
SCALE: NOT TO SCALE
4
POINT-OF-USE MIXING VALVE SENSOR OPERATED DIAGRAM
REMOVAL OF ALL PLUMBING FIXTURES, PIPING, EQUIPMENT, AND ASSOCIATED
APPURTENANCES. NO PERSON OTHER THAN A LICENSED PLUMBER SHALL REMOVE
PLUMBING ITEMS FROM THEIR ORIGINAL LOCATION.
B. SHUTDOWN OF EXISTING SYSTEMS SHALL BE COORDINATED WITH OWNER TO LIMIT
INTERFERENCE WITH OWNER'S OPERATION AND DOWNTIME. CONTRACTOR SHALL
SUBMIT TO OWNER FOR REVIEW AND APPROVAL, THE PROPOSED PHASING PLAN FOR
SHUTDOWN OF EXISTING SERVICES.
C. CONTRACTOR SHALL COMPLY WITH GENERAL CONDITIONS AND PROTECTION
PROVISIONS SPECIFIED FOR JOINT OWNER/CONTRACTOR OCCUPANCY WORK AREAS.
D. CONTRACTOR SHALL PROTECT EXISTING UTILITIES TO REMAIN FROM DAMAGE DURING
DEMOLITION. ANY UTILITIES AND SERVICES DAMAGED SHALL BE REPAIRED AT NO
EXPENSE TO OWNER.
E. CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO TEMPORARILY
MOVING OR TAKING EQUIPMENT OUT OF SERVICE AS NECESSARY TO COMPLETE
WORK.
F. WHERE APPLICABLE, THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE
OWNER AND GENERAL TRADE FOR ANY WALL AND CEILING OPENINGS IN WHICH
PLUMBING WORK IS TO BE PERFORMED. GENERAL TRADE SHALL BE RESPONSIBLE FOR
PATCHING SUCH WALL AND CEILING OPENINGS TO MATCH EXISTING ONCE PLUMBING
INSTALLATION HAS BEEN COMPLETED. WHERE PLUMBING CONTRACTOR IS PRIME,
THEY WILL BE RESPONSIBLE FOR ARRANGING ALL WORK DESCRIBED ABOVE AND
INCLUDE RELATED COST IN BID.
G. WHERE APPLICABLE THE PLUMBING CONTRACTOR SHALL DEMARCATE EXISTING
CONCRETE FLOOR AREAS FOR SAW CUT AND REMOVAL BY GENERAL TRADE.
PLUMBING CONTRACTOR SHALL PROVIDE ALL EXCAVATION AND BACKFILL REQUIRED
FOR INSTALLATION OF SYSTEM PIPING AND SPECIALTIES. GENERAL TRADE WILL BE
RESPONSIBLE FOR PATCHING FLOOR AREAS FLUSH TO MATCH WITH EXISTING FLOOR
ONCE PLUMBING INSTALLATION HAS BEEN COMPLETED. WHERE PLUMBING
CONTRACTOR IS PRIME, THEY WILL BE RESPONSIBLE FOR ARRANGING ALL WORK
DESCRIBED ABOVE AND INCLUDE RELATED COST IN BID.
A. WORK SHALL BE PERFORMED BY A LICENSED PLUMBER OF THE STATE OF COLORADO.
B. MATERIALS, INSTALLATION AND TESTING SHALL BE IN ACCORDANCE WITH THE LATEST
ADOPTED EDITION OF STATE AND LOCAL CODE PROCEDURES, METHODS AND
REQUIREMENTS, INCLUDING THE MOST STRINGENT OF HEALTH AND SAFETY
STANDARDS AS REQUIRED AND AS INTERPRETED BY THE AUTHORITY HAVING
JURISDICTION. APPLICABLE CODES AND STANDARDS INCLUDE, BUT ARE NOT LIMITED
TO THE FOLLOWING:
"COLORADO STATE PLUMBING CODE" 2019 EDITION
"INTERNATIONAL PLUMBING CODE" 2018 EDITION
"INTERNATIONAL FUEL GAS CODE" 2018 EDITION
"INTERNATIONAL ENERGY CONSERVATION CODE" 2018 EDITION
"NFPA 54 - NATIONAL FUEL GAS CODE"
APPLICABLE LOCAL AND MUNICIPAL CODES AND ORDINANCES.
C. MEANING AND INTENT OF DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND PLUMBING
SYSTEMS ARE SHOWN IN SCHEMATIC FORM. DRAWINGS DO NOT SHOW EVERY
PLUMBING SYSTEM COMPONENT AND SHOULD BE FOLLOWED AS CLOSELY AS
CIRCUMSTANCES WILL PERMIT. PLUMBING SYSTEM INSTALLATIONS RELATED TO THIS
PROJECT SHALL BE PROVIDED TO MEET THE INTENT AND MEANING OF THE DRAWINGS
IN COMPLIANCE WITH APPLICABLE CODES, AND STANDARDS. WHERE APPLICABLE THE
PLUMBING CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO INSTALLATION.
REPORT ANY QUESTIONS, OR CONCERNS TO THE ARCHITECT/ENGINEER PRIOR TO
PROCEEDING WITH WORK. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED
DIMENSIONS. MINOR CHANGES IN LOCATIONS OF PLUMBING EQUIPMENT, &/OR
SYSTEMS FROM THOSE INDICATED ON DRAWINGS SHALL BE MADE WITHOUT EXTRA
COST. A COMPLETE AND OPERATIONAL PLUMBING SYSTEM SHALL BE PROVIDED.
D. THE PLUMBING CONTRACTOR SHALL REFER TO BOTH DRAWINGS AND SPECIFICATIONS
FOR ALL PLUMBING CRITERIA REQUIRED FOR THIS PROJECT.
E. PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL PLUMBING UTILITY SERVICES FROM
5'-0" OUTSIDE BUILDING FOUNDATION WALL TO WITHIN THE BUILDING UNLESS NOTED
OTHERWISE ON PLANS. SEE SITE UTILITY PLANS FOR RELATED SITE UTILITY WORK BY
OTHERS.
F. COORDINATE ROUTING OF PIPING WITH ALL OTHER TRADES AND STRUCTURAL
CONDITIONS TO AVOID ANY ROUTING CONFLICTS OR SERVICE INTERFERENCES.
G. MAINTAIN A MINIMUM CLEARANCE IN FRONT OF AND FROM EITHER SIDE OF
ELECTRICAL PANELS, EQUIPMENT, ETC., AS OUTLINED IN NEC STANDARDS. PIPE
SYSTEMS SHALL NOT BE ROUTED DIRECTLY OVER PANELS, EQUIPMENT, ETC.
H. INCLUDE IN BID, ALL LICENSE, PERMIT, INSPECTION AND OTHER FEES REQUIRED BY
UTILITY COMPANIES OR AUTHORITIES HAVING JURISDICTION REQUIRED FOR
COMPLETION OF WORK SO THAT NO UNEXPECTED ADDITIONAL EXPENSES ARE
INTRODUCED TO OWNER.
I. ALL CLEANOUTS, VALVES, WATER HAMMER ARRESTORS, ETC. ARE TO BE ACCESSIBLE.
EXTEND PIPING AND COORDINATE ACCESS PANEL SIZE AND LOCATION AS NECESSARY.
J. PLUMBING CONTRACTOR SHALL CLEAN WORK AREA OF ALL DUST AND DEBRIS
GENERATED BY THEIR WORK AT THE END OF EACH WORK DAY.
K. ALL PLUMBING SYSTEM VALVES SHALL BE INSTALLED IN A LOCATION AND ORIENTATION
THAT WILL PERMIT INTENDED USE.
L. PROVIDE STOPS AND/OR ISOLATION VALVES TO EACH INDIVIDUAL FIXTURE, FIXTURE
GROUP OR PIECE OF EQUIPMENT PER APPLICABLE CODES TO ALLOW FOR INDIVIDUAL
SERVICING UNLESS NOTED OTHERWISE ON PLANS.
M. SANITARY WASTE PIPING SHALL BE SLOPED AT 1/8-INCH PER FOOT MINIMUM FOR ALL
PIPING 4-INCH AND LARGER AND AT 1/4-INCH PER FOOT MINIMUM FOR ALL PIPING 3-
INCH AND SMALLER.
N. INDIRECT DRAIN PIPING FROM FIXTURES, SPECIALTIES, AND EQUIPMENT SHALL BE
ROUTED TO FLOOR DRAIN OR OTHER APPROVED RECEPTACLE AND TERMINATED WITH
AN AIR GAP 2 TIMES THE DIAMETER OF THE DRAIN PIPING, BUT NOT LESS THAN 1 INCH
GAP. SUPPORT PIPING SO DRAIN PIPING CANNOT BE DEFLECTED FROM DRAIN
SOURCE.
O. ALL VENTS FROM HORIZONTAL SOIL OR WASTE PIPE SHALL COME OFF TOP OR AT 45
DEGREE VERTICALLY FROM CENTER OF PIPE BEFORE OFFSETTING HORIZONTALLY TO
RISER.
P. ALL VENT TERMINATIONS SHALL BE COORDINATED WITH BUILDING OPENINGS, AIR
INTAKES AND AIR EXHAUST OPENINGS. ADJUST VENT THROUGH ROOF LOCATIONS TO
COMPLY WITH APPLICABLE CODE.
Q. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING ALL HANGERS AND
SUPPORTS ARE SECURELY ANCHORED OR ATTACHED TO BUILDING ELEMENTS
ADEQUATE FOR INTENDED PLUMBING SYSTEM OR EQUIPMENT.
R. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL NAIL PLATES WHERE PIPING
PASSES THROUGH STUD(S) WITHIN 2" OF NAILING SURFACE TO PROTECT PIPE FROM
NAILS OR DRYWALL SCREWS.
S. PLUMBING CONTRACTOR SHALL PROVIDE APPROVED WATER HAMMER ARRESTORS IN
WATER LINES SERVING QUICK-CLOSING VALVES, BATTERIED, OR BACK TO BACK
FIXTURES WITH INDIVIDUAL ISOLATION VALVES.
T. ALL NEWLY INSTALLED CIRCULATED HOT WATER SHALL BE WITHIN THE MAXIMUM
ALLOWABLE PIPE LENGTH TO TERMINATE AT EACH FIXTURE, OR APPLIANCE AS
OUTLINED IN THE INTERNATIONAL ENERGY CONSERVATION CODE. SPECIAL ATTENTION
SHOULD BE PAID TO PUBLIC LAVATORIES WHERE MAXIMUM PIPE LENGTHS ARE
LIMITED. REFER TO PLUMBING PLANS AND DETAILS FOR CLARIFICATION.
U. ALL P-TRAPS FOR FLOOR DRAINS AND FLOOR SINKS SHALL BE DEEP SEAL TYPE. TRAPS
SHALL MAINTAIN THE SEWER GAS SEALS BY MEANS OF A PRIMING DEVICE DESIGNED
FOR SUCH PURPOSES OR BY OTHER METHODS AS ACCEPTABLE BY CODE AND AHJ.
V. PLUMBING CONTRACTOR TO INSTALL, TEST, AND FIELD BALANCE APPROVED
EQUIPMENT PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND
RECOMMENDATIONS.
W. PROVIDE INSULATION FOR THE PLUMBING PIPING SYSTEMS DESCRIBED IN THESE
DRAWINGS AS PER THE IPC AND THE IECC.
HWC
HW
3-WAY CONTROL VALVE
ANGLE GATE VALVE
ANGLE GLOBE VALVE
BALANCING/SHUTOFF VALVE
BALL VALVE
BUTTERFLY VALVE
CHECK VALVE
CALIBRATED BALANCING VALVE
CONTROL VALVE
EXPANSION VALVE
GATE VALVE
GLOBE VALVE
QUICK OPEN VALVE
SAFETY RELIEF VALVE
SOLENOID VALVE
BACKFLOW PREVENTER
ECCENTRIC REDUCER
CONCENTRIC REDUCER
FLOW ARROW
HOSE BIBB / SILLCOCK
WALL CLEANOUT
WATER CLOSET
VENT THRU ROOF
VACUUM BREAKER
THERMOSTATIC MIXING VALVE
TO BELOW
SILLCOCK (EXTERIOR)
PLUMBING CONTRACTOR
MOP SINK BASIN
LAVATORY
HOT WATER RECIRCULATION PUMP
HOSE BIBB (INTERIOR)
HIGH AS POSSIBLE
GENERAL CONTRACTOR
FROM FLOOR ABOVE
FLOOR CLEANOUT
FURNISHED BY OTHERS
ELECTRICAL CONTRACTOR
BELOW GRADE
BELOW FLOOR
ABOVE FINISHED FLOOR
ABOVE CEILING
PLUMBING EQUIPMENT DESIGNATION
AC
AFF
BF
BG
EC
FBO
FCO
FFA
GC
HAP
HB
HWCP
L
MSB
PC
SC
TB
TMV
VB
VTR
WC
WCO
SP SUMP PUMP
UR URINAL
EWC ELECTRIC WATER COOLER
FD FLOOR DRAIN
RD ROOF DRAIN
CSS CLINICAL SERVICE SINK
ET EXPANSION TANK
FA FROM ABOVE
FB FROM BELOW
FFB FROM FLOOR BELOW
FT FILL TANK
GWH GAS WATER HEATER
TFB TO FLOOR BELOW
TFA TO FLOOR ABOVE
WF WASH FOUNTAIN
VACUUM RELIEF VALVE
SH SHOWER
EWH ELECTRIC WATER HEATER
SS SERVICE SINK
LT LAUNDRY TUB
IM ICE MAKER
HS HOSE STATION
ESHSHOWER COMB. EMERGENCY EYE WASH/
EEWWASH EMERGENCY EYE
DWDISHWASHER
CF COMBINATION FIXTURE
WB WASHER BOX
SK SINK
WS WATER SOFTENER
BH BOOSTER HEATER
PIPING SYSTEM
DF DRINKING FOUNTAIN
NOTE: NOT ALL SYMBOLS ARE USED IN CONSTRUCTION DOCUMENTS
GAS COCK
PLUG VALVE
BAS BUILDING AUTOMATION SYSTEM
BFP BACKFLOW PREVENTION DEVICE
BJ BETWEEN JOISTS
BOP BOTTOM OF PIPE
BTUH BRITISH THERMAL UNITS PER HOUR
COND CONDENSATE
CP CONDENSATE PUMP
CV CONTROL VALVE
DN DOWN
FPC FIRE PROTECTION SUBCONTRACTOR
GPM GALLONS PER MINUTE
MBH THOUSANDS OF BTU PER HOUR
P PUMP
PRV PRESSURE RELIEF VALVE
TOP TOP OF PIPE
NTS NOT TO SCALE
GENERAL
SF SQUARE FOOT
SE SEWAGE EJECTOR
EXISTING
PLUMBING KEYNOTE
KITCHEN EQUIPMENT DESIGNATION
POINT OF NEW CONNECTION
POINT OF TERMINATION/CAP
NEW BOLD TEXT INDICATES NEW ITEM
ITALIC TEXT INDICATES EXISTING ITEM
#
PRESSURE REDUCING VALVE (WATER)
PRESSURE REGULATOR (GAS)
PIPE ANCHOR
PIPE GUIDES
WALL CLEANOUT
SUSPENDED CLEANOUT
WCO
WYE STRAINER
WYE STRAINER W/DRAIN VALVE
FLOOR DRAIN - ROUND OR SQUARE
FLOOR CLEANOUT - ROUND OR SQUARE
PIPE CAP
PIPE TURNING DOWN
PIPE TURNING UP
TEE UP
TEE DOWN
DROP AND RUN
DROP AND TURN
TEE OFF TOP
TEE OFF BOTTOM
CROSS AND RISER
PLAN 90° ELBOW
PIPE TEE
PIPE UNION
FLEXIBLE PIPE CONNECTOR
WATER METER
PUMP
AUTOMATIC AIR VENT
PRESSURE SWITCH
PRESSURE GAUGE
THERMOMETER
FLOW SWITCH
TEMPERATURE SWITCH
G NATURAL GAS
ST STORM
PD PUMP DISCHARGE
OST OVERFLOW STORM
GW GREASE WASTE
OW OIL WASTE
W SANITARY WASTE
CD CONDENSATE DRAIN
FS FLOOR SINK
MC MECHANICAL CONTRACTOR
ORD OVERFLOW ROOF DRAIN
CA COMPRESSED AIR
AW ACID WASTE
N2 NITROGEN
N2O NITROUS OXIDE
MA MEDICAL AIR
O2 OXYGEN
WAGD WASTE ANESTHETIC GAS DISPOSAL
VAC VACUUM
V SANITARY VENT
OV OIL VENT
AV ACID VENT
NPCW NONPOTABLE COLD WATER
DI DE-IONIZED WATER
SCW SOFTENED COLD WATER
CW DOMESTIC COLD WATER
RO REVERSE OSMOSIS WATER
DOMESTIC HW RECIRCULATION
DOMESTIC HOT WATER
CO2 CARBON DIOXIDE
HW (---) DOMESTIC HOT WATER (OTHER TEMP)
OR
OR
YCO YARD CLEANOUT
WFL WATER FILTER
CO
PIPE SLOPE ARROW
F
P
T
M
L1
K22
GD GARBAGE DISPOSAL
DS DOWNSPOUT NOZZLE
AD AREA DRAIN
SYMBOLS LEGEND ABBREVIATIONS
DEMOLITION
PIPING
LHW LAB HOT WATER
TW TEMPERED WATER
LINE STYLE INDICATES DEMOLISHED ITEM
LHWC LAB HW RECIRCULATION
FCW FILTERED COLD WATER
LCW LAB COLD WATER
SHEET #
DETAIL #
DETAIL OR SECTION MARK
##
#
FIRE PROTECTION GENERAL RENOVATION NOTES
A. DURING THE TIME THAT THE FIRE PROTECTION RENOVATION WORK IS BEING PERFORMED, AND THE FIRE PROTECTION SYSTEM IS DOWN AND OUT OF COMMISSION,
THE FIRE PROTECTION CONTRACTOR SHALL HAVE SUFFICIENT PERSONNEL ONSITE TO KEEP A “FIRE WATCH” ON THE FACILITY.
B. A FIRE PROTECTION WATCH IS IMPLEMENTED TO ENSURE THE FIRE SAFETY OF A BUILDING IN THE EVENT OF ANY ACT, OR SITUATION INSTIGATING AN INCREASED
RISK TO PERSONS OR PROPERTY. THE TERM “FIRE WATCH” IS USED TO DESCRIBE A DEDICATED PERSON OR PERSONS WHO’S SOLE RESPONSIBILITY IS TO LOOK
FOR FIRES WITHIN AN ESTABLISHED AREA.
C. IN THE OPINION OF THE FIRE AND LIFE-SAFETY GROUP (FLS) OF FACTORY MUTUAL (FM), ANY REQUIRED FIRE PROTECTION SYSTEM THAT IS OUT OF SERVICE FOR
MORE THAN 4 HOURS AND OCCUPIED IS REQUIRED TO ESTABLISH A FIRE WATCH. FOR THE PERSON OR PERSONS ASSIGNED TO THE FIRE WATCH, THIS MUST BE
THEIR ONLY JOB DUTY DURING THE TIME PERIOD OF THE FIRE PROTECTION RENOVATION WORK.
D. IN ADDITION THE BUILDING OWNER IS REQUIRED TO HAVE AN IMPAIRMENT COORDINATOR. THE OUT OF SERVICE EQUIPMENT MUST BE TAGGED “OUT OF SERVICE”.
AN OUT OF SERVICE TAG MUST BE PLACED AT THE FIRE ALARM PANEL AND THE FIRE DEPARTMENT CONNECTION (REFERENCE INTERNATIONAL FIRE CODE-
CHAPTER 9, SECTION 901.7).
E. FIRE WATCH PERSONNEL ARE TO KEEP WATCH FOR FIRES IN THE GENERAL AREA OF PERFORMANCE, THE PERSONS PERFORMING THE FIRE WATCH ARE NOT
PERMITTED TO PERFORM ANY OTHER DUTIES.
F. FIRE WATCH PERSONNEL ARE TO HAVE FIRE EXTINGUISHING EQUIPMENT READILY AVAILABLE AND TO BE TRAINED IN ITS USE.
G. THE QUANTITY OF PERSONNEL INVOLVED IN THE FIRE WATCH IS TO BE ADEQUATE SUCH THAT EACH FLOOR, LEVEL, AND ROOM OF THE FIRE AREA IS COVERED.
H. IN GENERAL, A FIRE WATCH IS TO FULFILL THE INTENT OF NFPA-72 AS FOLLOWS: 1. NOTIFY OCCUPANTS TO EVACUATE WHEN THERE IS A FIRE IN THE BUILDING; 2.
NOTIFY THE CENTRAL MONITORING STATION TO INITIATE EMERGENCY PERSONNEL RESPONSE; 3. ACTIVATE FIRE PROTECTION SYSTEMS IN ORDER TO RELEASE
DOOR HOLDERS, CLOSE SMOKE DAMPERS, AND SHUT DOWN FANS.
I. IF BUILDING OCCUPANTS ASSIST WITH FIRE WATCH DUTIES, THE PROCEDURES FOR CONTACTING EMERGENCY PERSONNEL AND EVACUATING THE BUILDING ARE
TO BE DISTRIBUTED TO BUILDING OCCUPANTS. FOR PLANNED OUTAGES, THE PROCEDURES ARE TO BE SENT TO THE BUILDING OWNER FOR DISTRIBUTION.
A. THE FIRE PROTECTION CONTRACTOR SHOULD USE NFPA-13 (CURRENT EDITION), “PLANS AND CALCULATIONS” AS A GUIDELINE WHEN PREPARING SUBMITTALS FOR
REVIEW. DISREGARD ONLY THOSE ITEMS NOT APPLICABLE TO THE INDIVIDUAL BUILDING SYSTEM. FIRE PROTECTION MATERIALS, EQUIPMENT AND INSTALLATION
SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA-13 FOR THE INSTALLATION OF AUTOMATIC SPRINKLER SYSTEM.
B. THE FIRE PROTECTION CONTRACTOR SHALL COMPLY WITH THE INTERNATIONAL BUILDING CODE (LATEST ADOPTED EDITION). INSTALLATION SHALL MEET THE
REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.
C. IT IS THE CONTRACTOR'S RESPONSIBILITY TO HYDRAULICALLY CALCULATE SPRINKLER REQUIREMENTS PER THE APPROPRIATE HAZARD OCCUPANCY AND PROVIDE
ACTUAL NUMBER OF HEADS, REQUIRED SPACING AND PIPE ROUTING AS REQUIRED FOR CLEARANCE WITH STRUCTURAL CONDITIONS AND OTHER TRADES TO
PROVIDE A COMPLETE AND OPERABLE SYSTEM IN ACCORDANCE WITH IFC, NFPA AND AUTHORITY HAVING JURISDICTION REQUIREMENTS.
D. SPRINKLER CONTRACTOR SHALL DESIGN THE SYSTEM AND ROUTE PIPING AS REQUIRED FOR CONFORMANCE WITH ACTUAL BUILDING CONDITIONS AND NFPA
REQUIREMENTS. COORDINATE SPRINKLER WORK WITH ALL OTHER TRADES TO AVOID CONFLICT.
E. SUPPORT ALL NEW PIPING AND EQUIPMENT FROM STRUCTURE ABOVE AS REQUIRED. CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTAL STEEL TO SPAN BETWEEN
PRIMARY BUILDING STRUCTURAL MEMBERS. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE DESIGN OF SUPPLEMENTAL STEEL AND SUPPORTS INCLUDING
REACTION LOADS AT PRIMARY BUILDING STRUCTURAL MEMBERS.
F. PROVIDE ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, ETC. REQUIRED FOR COMPLETE AND FUNCTIONAL SYSTEM AS SPECIFIED AND INDICATED ON THE DRAWINGS.
G. INCLUDE IN BID, ALL LICENSE, PERMIT, INSPECTION, AND OTHER FEES REQUIRED BY UTILITY COMPANIES OR AUTHORITIES HAVING JURISDICTION REQUIRED FOR
COMPLETION OF WORK SO NO ADDITIONAL EXPENSES ARE INTRODUCED TO OWNER.
H. PROMPTLY INFORM THE ENGINEER, IN WRITING, OF ANY DEVIATIONS IN THE CONTRACT DOCUMENTS FROM REQUIREMENTS OF LOCAL UTILITIES, MUNICIPALITIES,
STATE OR FEDERAL LAWS AND REGULATIONS. PERFORM WORK IN ACCORDANCE WITH SUCH REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER.
I. FIRE PROTECTION CONTRACTOR SHALL SUBMIT ONE COMPLETE SET OF AUTOMATIC SPRINKLER SYSTEM DRAWINGS, HYDRAULIC CALCULATIONS, CURRENT WATER
FLOW TEST, AND EQUIPMENT DATA BROCHURES AS PREPARED BY (OR PREPARED UNDER THE SUPERVISION OF) A PROFESSIONAL ENGINEER WHO SHALL BE
SEALING THE AFOREMENTIONED SYSTEM DRAWINGS. THE SUBMITTAL SHALL BE SENT TO ALL AUTHORITIES HAVING JURISDICTION FOR REVIEW AND APPROVAL.
SYSTEM SHALL ALSO BE IN COMPLIANCE WITH ALL REQUIRED PLUMBING CODES.
J. ALL EXPENSES CARRIED BY THE A/E IN TROUBLESHOOTING SYSTEM(S) PROBLEMS CAUSED BY INADEQUATE WORKMANSHIP, LACK OF TECHNICAL EXPERTISE OR
OTHER FORMS OF POOR PERFORMANCE ON THE PART OF A CONTRACTOR, SHALL BE BORN BY THAT CONTRACTOR.
K. PROVIDE FIRE STOP / SEALANT AT ALL PIPE PENETRATIONS THROUGHOUT FIRE RATED WALLS. REVIEW ARCHITECTURAL PLANS PRIOR TO BIDDING AND INDICATE
FIRE-RATED PENETRATION LOCATIONS ON SPRINKLER LAYOUT SUBMITTAL.
L. FIRE PROTECTION CONTRACTOR SHALL FURNISH AND INSTALL ARMOVER SUPPORTS FOR ALL END OF LINE BRANCH LINES PER NFPA-13, SECTION: 9.2.3.4. REFER TO
A.9.2.3.4.3(B) FOR ACCEPTABLE.
M. ALL DROPS TO SPRINKLER HEADS SHALL TEE / ELBOW OFF TOP OF BRANCH PIPE, EXCEPT WHERE STRUCTURAL, ARCHITECTURAL OR MECHANICAL EQUIPMENT
CONDITIONS PRECLUDE CONVENTIONAL INSTALLATION.
N. THE CONTRACTOR SHALL VERIFY THE EXACT EXISTING CONDITIONS, INCLUDING ANY PERCEIVED CONCEALED SPACES, AND THE BUILDING TYPE AND CONSTRUCTION
AS OUTLINED IN THE INTERNATIONAL BUILDING CODE, PRIOR TO THE START OF WORK. REFER TO THE INTERNATIONAL BUILDING CODE, ESPECIALLY CHAPTERS 6
(TYPES OF CONSTRUCTION) AND CHAPTER 9 (FIRE PROTECTION SYSTEMS), NFPA 13, AND THE PROJECT SPECIFICATIONS FOR OTHER FIRE PROTECTION
REQUIREMENTS.
FIRE PROTECTION BUILDING AND OCCUPANT SAFETY FOR THE INTERRUPTION OF FIRE PROTECTION SERVICE
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
ISSUE:
# DATE: DESCRIPTION:
NOT FOR CONSTRUCTION
DESIGNED:
4/7/2020 10:16:29 AM
P0.1
GENERAL
INFORMATION
BAJ
CRF
0200100.04
Downtown Transit
Center - Restroom
Upgrades
City of Fort Collins
250 N. Mason St, Fort Collins, CO
04.08.2020
JMB
90% CD
22x10
R
18"ø 16"ø 10"ø
12x8
S
265
12x8
S
265
ON ROOF
1
6"ø
S
50
22x10
R
8"ø
S
230
18"ø 16"ø 10"ø
12x8
S
265
12x8
S
265
36"
MAX.
36"
MAX.
36"
MAX.
36"
MAX.
FLEXFLOW ELBOW AS
MANUFACTURED BY
THERMAFLEX
SHEET METAL
PLENUM
MANUAL VOLUME
DAMPER (TYP)
BRANCH DUCT
"SPIN-IN" TAKEOFF (TYP)
SUPPLY AIR
TRUNK DUCT
APPLICATION NOTES:
1. FLEXIBLE DUCTWORK IS
INTENDED FOR THE SOLE
PURPOSE OF DIFFUSER
ALIGNMENT.
2. UNDER NO CIRCUMSTANCE
WILL THE USE OF FLEXIBLE
DUCT BE ALLOWED IN
NEGATIVE PRESSURE
APPLICATIONS.
3. FLEXIBLE DUCTWORK MAY
BE INSTALLED ONLY ABOVE
ACCESSIBLE CEILINGS.
TOP TAKEOFF
SIDE TAKEOFF - ROUND
BOTTOM TAKEOFF
36"
MAX.
36"
MAX.
DESIGNER'S NOTE: FLEXFLOW ELBOW SUPPORT AND SHEET METAL PLENUM NOT ALLOWABLE ON ALL
PROJECTS
36"
MAX.
4" MIN.
SIDE TAKEOFF - ROUND
CONDUIT TO
WIRING POST
BY EC
DAMPER BY FAN
MANUFACTURER
DISCONNECT BY FAN
MANUFACTURER WITHIN
HOUSING
PREFABRICATED
ROOF CURB
REMOVABLE, SPUN
ALUMINUM
HOUSING
NON-FERROUS
BIRD SCREEN
WIRING POST
SHEET METAL PLENUM.
SEAL LOWER 6 INCHES
WATERTIGHT.
BRANCH DUCT
ROOF SYSTEM -
REFER TO
ARCHITECTURAL
DETAILS
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
ISSUE:
# DATE: DESCRIPTION:
NOT FOR CONSTRUCTION
DESIGNED:
4/7/2020 5:34:49 PM
M1.1
DEMO AND NEW
FLOORPLAN, NOTES,
AND DETAILS
BAJ
CRF
0200100.04
Downtown Transit
Center - Restroom
Upgrades
City of Fort Collins
250 N. Mason St, Fort Collins, CO
04.08.2020
BEB
90% CD
0 2 4 8
NORTH
TRUE
K. MECHANICAL SYSTEMS HAVE BEEN DESIGNED BASED UPON THE 2018 INTERNATIONAL
MECHANICAL CODE, 2018 INTERNATIONAL ENERGY CONSERVATION CODE.
J. DO NOT INSULATE EXPOSED SPIRAL DUCT AND EXHAUST DUCT UNLESS OTHERWISE
NOTED.
I. INSTALL DUCTS, UNLESS OTHERWISE INDICATED, VERTICALLY AND HORIZONTALLY,
PARALLEL AND PERPENDICULAR TO BUILDING LINES; AVOID DIAGONAL RUNS UNLESS
SPECIFICALLY INDICATED ON DRAWINGS.
H. COORDINATE SIZE AND LOCATION OF ALL OPENINGS REQUIRED FOR DUCT AND PIPE
PENETRATIONS THROUGH WALLS, FLOORS, AND ROOFS, WITH CONTRACTOR
RESPONSIBLE FOR ROUGH FRAMING. COORDINATE LOCATION OF AIR INTAKES WITH
EXHAUST AND PLUMBING VENTS SO THAT INTAKES ARE A MINIMUM OF 10 FEET FROM
EXHAUST OPENINGS OR PLUMBING VENTS.
G. FABRICATE RECTANGULAR DUCTS, ELBOWS, TRANSITIONS, OFFSETS, BRANCH
CONNECTIONS, AND OTHER CONSTRUCTION WITH GALVANIZED, SHEET STEEL,
ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS--METAL AND
FLEXIBLE." COMPLY WITH REQUIREMENTS FOR METAL THICKNESS, REINFORCING
TYPES AND INTERVALS, TIE-ROD APPLICATIONS, AND JOINT TYPES AND INTERVALS.
F. COMPLY WITH NFPA 90B, "INSTALLATION OF WARM AIR HEATING AND AIR
CONDITIONING SYSTEMS," UNLESS OTHERWISE INDICATED.
E. COMPLY WITH NFPA 90A, "INSTALLATION OF AIR CONDITIONING AND VENTILATING
SYSTEMS," UNLESS OTHERWISE INDICATED.
D. INSTALL EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER
BUILDING SYSTEMS AND COMPONENTS.
C. FINAL TEST AND BALANCE REPORT SHALL BE SUBMITTED FOR APPROVAL.
B. ALL EXTERIOR WALL AND ROOF PENETRATIONS SHALL BE SEALED WATER TIGHT.
A. ALL DUCTWORK IS SHOWN IN SCHEMATIC FORM. PROVIDE OFFSETS AS REQUIRED TO
MEET SPACE REQUIREMENTS AND TO AVOID INTERFERENCE WITH OTHER TRADES
AND FIELD CONDITIONS. EXACT LOCATION OF THE DUCTWORK MAY VARY ACCORDING
TO THE COORDINATED SPACE REQUIREMENTS. EACH TRADE SHALL BE RESPONSIBLE
FOR COORDINATION WITH OTHER TRADES.
GENERAL NOTES
SCALE: 1/4" = 1'-0"
2
VENTILATION PLAN
KEYNOTES #
1 RETURN GRILLE OPEN TO SPACE ABOVE.
2 8x8 EXHAUST DUCT UP TO EF-10 ON ROOF.
SCALE: 1/4" = 1'-0"
1
MECHANICAL DEMOLITION PLAN KEY PLAN
SCALE: NOT TO SCALE
3
FLEXIBLE DUCT CONNECTIONS
SCALE: NOT TO SCALE
4
DOWNFLOW ROOF EXHAUST FAN
CWWATER DOMESTIC COLD
CWP CONDENSER WATER PUMP
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
DC DRY COOLER
DN DOWN
DP DIFFERENTIAL PRESSURE
DS DUCT SILENCER
EA EXHAUST AIR
EBB ELECTRIC BASEBOARD HEATER
EF EXHAUST FAN
EG EXHAUST GRILLE (LESS DAMPER)
EHC ELECTRIC HEATING COIL
EL ELEVATION
ER EXHAUST REGISTER
ERV ENERGY RECOVERY VENTILATOR
ET EXPANSION TANK
FA FRESH AIR
FD FIRE DAMPER
FDC FLEXIBLE DUCT CONNECTION
FFA FROM FLOOR ABOVE
FFB FROM FLOOR BELOW
FPC FLEXIBLE PIPE CONNECTION
FPT FAN POWERED AIR TERMINAL
FT FINNED TUBE RADIATION
GF GAS FURNACE
GIH GRAVITY INTAKE HOOD
GPM GALLONS PER MINUTE
GR GLYCOL RETURN
GS GLYCOL SUPPLY
GUH GAS UNIT HEATER
HU HUMIDIFIER
HC HEATING COIL
HCWR DUAL TEMPERATURE RETURN
HCWS DUAL TEMPERATURE SUPPLY
HP HEAT PUMP
HPR HIGH PRESSURE STEAM RETURN
HPS HIGH PRESSURE STEAM SUPPLY
HRC HEAT RECOVERY COIL
HS HUMIDITY SENSOR
HWP HOT WATER PUMP
HWR HOT WATER RETURN
LOW PRESSURE STEAM SUPPLY
LOW PRESSURE STEAM RETURN
KITCHEN HOOD - COMMERCIAL
HEAT EXCHANGER
HOT WATER SUPPLY
LPS
LPR
KH
HX
HWS
THOUSANDS OF BTU PER HOUR
MOTORIZED DAMPER
MAKEUP AIR UNIT
MIXED AIR
MBH
MD
MAU
MA
OBD OPPOSED BLADE DAMPER
P PUMP
PBD PARALLEL BLADE DAMPER
PRV PRESSURE RELIEF VALVE
PS PRESSURE SWITCH
PSI POUNDS PER SQUARE INCH
PTAC
RA RETURN AIR
RF RETURN AIR FAN
RG RETURN GRILLE (LESS DAMPER)
RH ROOF HOOD
RHC REHEAT COIL
RLFA RELIEF AIR
RPZ REDUCED PRESSURE BFP
RR RETURN REGISTER (WITH DAMPER)
RTU ROOFTOP AIR HANDLING UNIT
SA SUPPLY AIR
SAS SELF-ACTING SHUTTER
SD SUPPLY DIFFUSER/SMOKE DAMPER
SF SUPPLY FAN / SQUARE FOOT
SFD SMOKE/FIRE DAMPER
SG SUPPLY GRILLE
SR SUPPLY REGISTER
TCAC TEMP. CONTROL AIR COMPRESSOR
TCAD TEMP. CONTROL AIR DRYER
TDV TRIPLE DUTY VALVE
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
TOD TOP OF DUCT
TOP TOP OF PIPE
UC UNIT COOLER
UFD UNDERFLOOR DUCT
UH UNIT HEATER
UV UNIT VENTILATOR
VAV VARIABLE AIR VOLUME TERMINAL
VD VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
AUTOMATIC AIR VENT
TEMPERATURE SENSOR/SWITCH
PRESSURE GAUGE
THERMOMETER
PIPE ANCHOR
PIPE GUIDES
MANUAL AIR VENT
FLOW SENSOR/SWITCH
PIPE EXPANSION JOINT
PIPE UNION
CONCENTRIC REDUCER
ECCENTRIC REDUCER
WYE STRAINER
WYE STRAINER W/DRAIN VALVE
DIRECTION OF FLOW
STEAM BUCKET TRAP
STEAM F&T TRAP
BACKFLOW PREVENTER
PIPE TURNING UP
PIPE TURNING DOWN
TEE OFF TOP
TEE OFF BOTTOM
PIPE TEE
PIPE CAP
PLAN 90 DEGREE ELBOW
PLAN 45 DEGREE ELBOW
PIPING SYSTEM (SOLID LINE)
PIPING SYSTEM (DASHED LINE)
MOTORIZED SHUTTER
NOT TO SCALE
MS
NTS
GENERAL
HYDRONIC VENTILATION
GENERAL NOTES
COMMON REQUIREMENTS PIPING SYSTEM REQUIREMENTS
DEMOLITION
DESIGN CONDITIONS
DUCTWORK REQUIREMENTS
UFT UNDERFLOOR FAN TERMINAL
HRV HEAT RECOVERY VENTILATOR (SENSIBLE)
EUH ELECTRIC UNIT HEATER
ESP EXTERNAL STATIC PRESSURE
ISP INTERNAL STATIC PRESSURE
TSP TOTAL STATIC PRESSURE
PUMP
PC PLUMBING CONTRACTOR
EC ELECTRICAL CONTRACTOR
GC GENERAL CONTRACTOR
FLEXIBLE PIPE CONNECTOR
FCU FAN COIL UNIT
AL ALUMINUM
VRP VERTICAL RADIANT PANEL
WAC WINDOW / WALL AIR CONDITIONER
DAC DOOR AIR CURTAIN
DH DEHUMIDIFIER
DOAS DEDICATED OUTDOOR AIR SYSTEM
DSU DUCTLESS SPLIT UNIT
DX DX COOLING COIL
ERP ELECTRIC RADIANT PANEL
GRH GAS RADIANT HEATER
L LOUVER
PDH POOL ROOM DEHUMIDIFIER
PACKAGED TERMINAL AIR CONDITIONER
RP RADIANT PANEL
S1
12x12
250
EXISTING
EQUIPMENT TYPE
EQUIPMENT MARK
SHEET #
DETAIL #
AIRFLOW IN CFM
THROAT SIZE
MECHANICAL EQUIPMENT TAG
AIR TERMINAL DESIGNATION
KEYNOTE
DETAIL OR SECTION MARK
POINT OF NEW CONNECTION
CAP EXISTING PIPE OR DUCT
BOLD TEXT INDICATES PROPOSED ITEM
ITALIC TEXT INDICATES EXISTING ITEM
NEW
##
#
#
PRESSURE/TEMPERATURE PLUG
AHU-1
GUARD LOCKABLE GUARD WHERE INDICATED
EQUIPMENT TO BE CONTROLLED
GUARD
TEMP
HUMID
CO
ELEMENT TO BE MONITORED
LOCKABLE GUARD WHERE INDICATED
HUMIDISTAT
THERMOSTAT
SENSOR
SUPPLY DIFFUSER/REGISTER
RETURN REGISTER/GRILLE
EXHAUST REGISTER/GRILLE
DIFFUSER AIRFLOW PATTERN IF
OTHER THAN 4-WAY BLOW
FLEXIBLE BRANCH RUNOUT TO SUPPLY
DIFFUSER, 36" MAX LENGTH
CEILING RETURN REGISTER WITH LINED
DUCT FOR SOUND ATTENUATION OPEN
TO CEILING PLENUM
FLEXIBLE DUCT CONNECTION TO
EQUIPMENT OR BETWEEN DUCTS
VOLUME DAMPER
MOTORIZED DAMPER
FIRE DAMPER
SMOKE DAMPER
COMBINATION FIRE/SMOKE DAMPER
SUPPLY AIR DUCT TOWARDS
SUPPLY AIR DUCT AWAY
RETURN/OUTDOOR AIR DUCT TOWARDS
RETURN/OUTDOOR AIR DUCT AWAY
TRANSFER AIR
A. THIS FACILITY HAS BEEN DESIGNATED A "SMOKE-FREE" ENVIRONMENT. NO MECHANICAL VENTILATION
PROVISIONS HAVE BEEN MADE TO ACCOMMODATE TOBACCO USAGE BY THE BUILDING OCCUPANTS
B. ALL MECHANICAL SYSTEMS SHALL BE INSTALLED TO THE SATISFACTION OF THE LOCAL CODE
AUTHORITIES HAVING JURISDICTION
A. INSTALL EQUIPMENT TO ALLOW MAXIMUM POSSIBLE HEADROOM UNLESS SPECIFIC MOUNTING
HEIGHTS ARE INDICATED
B. INSTALL EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER BUILDING
SYSTEMS AND COMPONENTS IN EXPOSED INTERIOR SPACES, UNLESS OTHERWISE INDICATED
C. INSTALL HVAC EQUIPMENT TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR OR REPLACEMENT
OF COMPONENTS. CONNECT EQUIPMENT FOR EASE OF REMOVAL, WITH MINIMUM INTERFERENCE TO
OTHER INSTALLATIONS
D. ALL MECHANICAL EQUIPMENT WITH THE EXCEPTION OF AIR HANDLING UNITS, SUPPORTED FROM
FLOOR STRUCTURE SHALL BE MOUNTED ON 4" THICK CONCRETE HOUSEKEEPING PADS UNLESS
NOTED OTHERWISE. AIR-HANDLING UNITS SHALL BE MOUNTED ON 6" THICK CONCRETE
HOUSEKEEPING PADS TO ACCOMMODATE PROPER TRAPPING OF THE CONDENSATE DRAIN
E. AIR FILTERS SHALL BE REPLACED IN ALL AIR HANDLING EQUIPMENT EMPLOYING SUCH PRIOR TO
FINAL COMPLETION AND OWNER OCCUPANCY
F. THE INSTALLING CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ALL MECHANICAL EQUIPMENT
PUT INTO OPERATION PRIOR TO THE INSTALLATION OF A WORKING CONTROL SYSTEM, TESTING, AND
BALANCING, AND SUBSTANTIAL COMPLETION. ALL RETURN AND EXHAUST DUCT OPENINGS SHALL BE
COVERED WITH ROLL TYPE FILTER MEDIA DURING SUCH TEMPORARY OPERATION. OPERATION OF
THE MECHANICAL EQUIPMENT PRIOR TO FINAL COMPLETION SHALL NOT IMPACT THE EQUIPMENT
WARRANTY. MINIMUM 1-YEAR FROM SUBSTANTIAL COMPLETION UNLESS SPECIFIED OTHERWISE
G. PROVIDE FLEXIBLE DUCT CONNECTION BETWEEN MOTOR DRIVEN MECHANICAL UNITS AND SHEET
METAL SUPPLY, OUTDOOR AIR, EXHAUST, AND/OR RETURN AIR DUCTWORK CONNECTIONS
H. PROVIDE FLEXIBLE PIPE CONNECTION BETWEEN MOTOR DRIVEN MECHANICAL UNITS AND
CONNECTING PIPING
I. BASIS OF DESIGN MECHANICAL EQUIPMENT IS AS SCHEDULED ON THE DRAWINGS. INSTALLING
CONTRACTOR ASSUMES RESPONSIBILITY FOR COORDINATING PHYSICAL SPACE REQUIREMENTS OF
EQUIVALENT CAPACITY MECHANICAL EQUIPMENT DEEMED ACCEPTABLE BY THE ENGINEER
J. MECHANICAL EQUIPMENT FACTORY FINISH DAMAGED DURING THE COURSE OF CONSTRUCTION
SHALL BE RESTORED TO ORIGINAL CONDITION PRIOR TO FINAL ACCEPTANCE
A. DUCTWORK IS SHOWN IN SCHEMATIC FORM. ALL REQUIRED DUCT RISERS AND DROPS TO ALLOW
GENERAL ROUTING DEPICTED MAY NOT BE SHOWN. PROVIDE OFFSETS AS REQUIRED TO MEET SPACE
REQUIREMENTS AND TO AVOID INTERFERENCE WITH OTHER TRADES AND FIELD CONDITIONS. EXACT
LOCATION OF THE DUCTWORK MAY VARY ACCORDING TO THE COORDINATED SPACE REQUIREMENTS.
EACH TRADE SHALL BE TOTALLY RESPONSIBLE FOR COORDINATION WITH OTHER TRADES. NOTIFY
ENGINEER OF CONDITIONS REPRESENTING SIGNIFICANT CHANGES TO THE DESIGNED ROUTING
B. COMPLY WITH NFPA 90A, "INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS," UNLESS
OTHERWISE INDICATED
C. COMPLY WITH NFPA 90B, "INSTALLATION OF WARM AIR HEATING AND AIR CONDITIONING SYSTEMS,"
UNLESS OTHERWISE INDICATED
D. FABRICATE RECTANGULAR DUCTS, ELBOWS, TRANSITIONS, OFFSETS, BRANCH CONNECTIONS, AND
OTHER CONSTRUCTION WITH GALVANIZED, SHEET STEEL, ACCORDING TO SMACNA'S "HVAC DUCT
CONSTRUCTION STANDARDS--METAL AND FLEXIBLE." COMPLY WITH REQUIREMENTS FOR METAL
THICKNESS, REINFORCING TYPES AND INTERVALS, TIE-ROD APPLICATIONS, AND JOINT TYPES AND
INTERVALS
E. COORDINATE SIZE, QUANTITY, AND LOCATION OF ALL OPENINGS REQUIRED FOR DUCT AND PIPE
PENETRATIONS THROUGH WALLS, FLOORS, AND ROOFS, WITH CONTRACTOR RESPONSIBLE FOR ROUGH
FRAMING. COORDINATE LOCATION OF AIR INTAKES WITH EXHAUST AND PLUMBING VENTS SO THAT
INTAKES ARE A MINIMUM OF 10 FEET FROM EXHAUST OPENINGS OR PLUMBING VENTS
F. INSTALL DUCTS IN LONGEST LENGTH POSSIBLE AND FEWEST POSSIBLE JOINTS. INSTALL FABRICATED
FITTINGS FOR CHANGES IN DIRECTIONS, CHANGES IN SIZE AND SHAPE, AND CONNECTIONS
G. INSTALL DUCTS, UNLESS OTHERWISE INDICATED, VERTICALLY AND HORIZONTALLY, PARALLEL AND
PERPENDICULAR TO BUILDING LINES; AVOID DIAGONAL RUNS UNLESS SPECIFICALLY INDICATED ON
DRAWINGS
H. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING MOUNTED
DEVICES. COORDINATE MECHANICAL CEILING DEVICES SUCH AS DIFFUSERS AND REGISTERS WITH
LIGHT FIXTURES, SPEAKERS, SPRINKLER HEADS, ETC.
I. ELECTRICAL EQUIPMENT SPACES: ROUTE DUCTWORK TO AVOID PASSING THROUGH TRANSFORMER
VAULTS AND ELECTRICAL EQUIPMENT SPACES AND ENCLOSURES. AVOID ROUTING DUCTWORK
DIRECTLY ABOVE ELECTRICAL EQUIPMENT UNLESS SPECIFICALLY INDICATED ON THE MECHANICAL
DRAWINGS
J. NON-FIRE-RATED PARTITION PENETRATIONS: WHERE DUCTS PASS THROUGH INTERIOR PARTITIONS
AND ARE EXPOSED TO VIEW IN MECHANICAL ROOMS, CONCEAL SPACE BETWEEN CONSTRUCTION
OPENING AND DUCT OR DUCT INSULATION WITH SHEET METAL FLANGES OF SAME METAL THICKNESS AS
DUCT. OVERLAP OPENING ON FOUR SIDES BY AT LEAST 1-1/2 INCHES UNLESS INDICATED OTHERWISE
K. FIRE-RATED PARTITION PENETRATIONS: WHERE DUCTS PASS THROUGH INTERIOR PARTITIONS, INSTALL
APPROPRIATELY RATED FIRE DAMPER. FIRE DAMPER INSTALLATION MUST STRICTLY ADHERE TO
MANUFACTURER'S WRITTEN INSTRUCTIONS
L. PROVIDE MANUAL VOLUME-CONTROL BALANCING DAMPER AT ALL BRANCH DUCTS AND AT ALL OTHER
LOCATIONS REQUIRED FOR A COMPLETE AND BALANCEABLE AIR DISTRIBUTION SYSTEM
M. BALANCE ENTIRE AIR DISTRIBUTION SYSTEM TO AIRFLOW QUANTITIES INDICATED ON MECHANICAL
DRAWINGS
N. FLEXIBLE DUCTWORK SHALL BE ALLOWED ONLY IN POSITIVE PRESSURE APPLICATIONS AT SUPPLY
BRANCH RUNOUTS TO DIFFUSERS ABOVE ACCESSIBLE CEILINGS. FLEXIBLE DUCTWORK SHALL NOT
EXCEED 36" IN LENGTH. 90 DEGREE TURNS SHALL ONLY BE ALLOWED IF RETAINING BANDS EQUAL TO
THERMAFLEX "FLEX-FLOW" ARE EMPLOYED. UNDER NO CIRCUMSTANCES SHALL FLEXIBLE DUCTWORK
BE ALLOWED IN NEGATIVE PRESSURE APPLICATIONS
A. VERIFY EXACT SIZE AND LOCATION OF EXISTING UTILITIES PRIOR TO START OF DEMOLITION WORK
B. RELOCATE, REMOVE, AND ADJUST ALL MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO
ACCOMPLISH SCOPE OF NEW WORK
C. EXISTING MECHANICAL ITEMS ARE SHOWN IN SCHEMATIC FORM BASED UPON EXISTING
CONSTRUCTION DOCUMENTS AND/OR FIELD INVESTIGATION
D. REMOVE EXISTING PIPING AND DUCTWORK BACK TO LAST ACTIVE SERVICE AND CAP
E. FIXTURES AND EQUIPMENT INDICATED TO BE REUSED OR SALVAGED SHALL REMAIN THE
PROPERTY OF THE OWNER AND BE STORED IN A LOCATION AS DIRECTED BY OWNER'S
REPRESENTATIVE
F. IN LOCATIONS WHERE EXISTING CONSTRUCTION IS REMOVED AND NO ADDITIONAL CONSTRUCTION
IS INDICATED, PATCH EXISTING CONSTRUCTION TO MATCH ADJACENT SURFACES AND FINISHES
G. CONNECTIONS TO, AND SHUTDOWNS OF, EXISTING SYSTEMS SHALL BE COORDINATED WITH
OWNER'S REPRESENTATIVE TO ALLOW MINIMUM INTERFERENCE WITH OWNER'S OPERATION AND
DOWNTIME OF EXISTING UTILITIES. CONTRACTOR SHALL SUBMIT TO OWNER FOR REVIEW AND
APPROVAL THE PROPOSED PHASING PLAN FOR CONNECTING NEW SERVICES TO EXISTING
A. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT
OF PIPING SYSTEMS. INDICATED LOCATIONS AND ARRANGEMENTS WERE USED TO SIZE PIPE AND
CALCULATE FRICTION LOSS, EXPANSION, PUMP SIZING, AND OTHER DESIGN CONSIDERATIONS.
INSTALL PIPING AS INDICATED UNLESS DEVIATIONS TO LAYOUT ARE APPROVED BY ENGINEER
B. DELIVER PIPES AND TUBES WITH FACTORY-APPLIED END CAPS. MAINTAIN END CAPS THROUGH
SHIPPING, STORAGE, AND HANDLING TO PREVENT PIPE END DAMAGE AND TO PREVENT ENTRANCE OF
DIRT, DEBRIS, AND MOISTURE
C. COORDINATE PIPE ROUTINGS, CHASES, AND OPENINGS IN BUILDING STRUCTURE WITH ALL TRADES
DURING PROGRESS OF CONSTRUCTION. COORDINATE INSTALLATION OF REQUIRED SUPPORTING
DEVICES AND SET SLEEVES IN POURED-IN-PLACE CONCRETE AND OTHER STRUCTURAL
COMPONENTS AS THEY ARE CONSTRUCTED
D. INSTALL PIPING IN CONCEALED LOCATIONS, UNLESS OTHERWISE INDICATED AND EXCEPT IN
EQUIPMENT ROOMS AND SERVICE AREAS. INSTALL PIPING INDICATED TO BE EXPOSED AND PIPING IN
EQUIPMENT ROOMS AND SERVICE AREAS AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS.
DIAGONAL RUNS ARE PROHIBITED UNLESS SPECIFICALLY INDICATED OTHERWISE
E. INSTALL PIPING ABOVE ACCESSIBLE CEILINGS TO ALLOW SUFFICIENT SPACE FOR CEILING PANEL
REMOVAL
F. INSTALL PIPING TO PERMIT VALVE SERVICING
G. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS
H. INSTALL PIPING TO ALLOW APPLICATION OF INSULATION
I. INSTALL ESCUTCHEONS FOR PENETRATIONS OF FINISHED WALLS, CEILINGS, AND FLOORS
J. SLEEVES ARE NOT REQUIRED FOR CORE-DRILLED HOLES.
K. PERMANENT SLEEVES ARE NOT REQUIRED FOR HOLES FORMED BY REMOVABLE PE SLEEVES
L. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS AND CONCRETE
FLOOR AND ROOF SLABS
M. UNDERGROUND, EXTERIOR-WALL PIPE PENETRATIONS: INSTALL CAST-IRON "WALL PIPES" FOR
SLEEVES. SEAL PIPE PENETRATIONS USING MECHANICAL SLEEVE SEALS. SELECT SLEEVE SIZE TO
ALLOW FOR 1-INCH ANNULAR CLEAR SPACE BETWEEN PIPE AND SLEEVE FOR INSTALLING
MECHANICAL SLEEVE SEALS
N. FIRE-BARRIER PENETRATIONS: MAINTAIN INDICATED FIRE RATING OF WALLS, PARTITIONS, CEILINGS,
AND FLOORS AT PIPE PENETRATIONS. SEAL PIPE PENETRATIONS WITH FIRESTOP MATERIALS.
O. VERIFY FINAL EQUIPMENT LOCATIONS FOR ROUGHING-IN.
MECHANICAL EQUIPMENT INSTALLATION
PRESSURE SENSOR/SWITCH
EXHAUST AIR DUCT TOWARDS
EXHAUST AIR DUCT AWAY
TJ THROUGH JOISTS
CHS CHILLED WATER SUPPLY
CO2
3-WAY CONTROL VALVE
ANGLE GATE VALVE
ANGLE GLOBE VALVE
BALANCING/SHUTOFF VALVE
BALL VALVE
BUTTERFLY VALVE
CHECK VALVE
CALIBRATED BALANCING VALVE
CONTROL VALVE
EXPANSION VALVE
GATE VALVE
GLOBE VALVE
QUICK OPEN VALVE
SAFETY RELIEF VALVE
SOLENOID VALVE
VACUUM RELIEF VALVE
GAS COCK
PLUG VALVE
PRESSURE REDUCING VALVE (WATER)
PRESSURE REGULATOR (GAS)
PIPE SLOPE ARROW
WALL SWITCH
H
S
T
CFM
F
P
T
12x8Φ FLAT OVAL DUCT
12"ø ROUND DUCT
12x8 RECTANGULAR DUCT
AHU
1
M METER
MC MECHANICAL CONTRACTOR
SYMBOLS LEGEND
NOTE: NOT ALL SYMBOLS ARE USED IN CONSTRUCTION DOCUMENTS
HVAC DESIGN LOAD CALCULATIONS ARE BASED ON THE FOLLOWING CLIMATE DATA:
CITY AND STATE: FORT COLLINS
WINTER OUTDOOR AMBIENT DB: -2.6
SUMMER OUTDOOR AMBIENT DB/WB: 90.1/60.9
MECHANICAL SYSTEMS HAVE BEEN DESIGNED BASED UPON THE 2018 INTERNATIONAL MECHANICAL
CODE, 2018 INTERNATIONAL ENERGY CONSERVATION CODE, NATIONAL FIRE PROTECTION (NFPA)
STANDARDS, AND ACCEPTED AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR-CONDITIONING
ENGINEERS (ASHRAE) ACCEPTED STANDARDS AND PRACTICES
ABBREVIATIONS
LINE STYLE INDICATES DEMOLISHED ITEM
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
ISSUE:
# DATE: DESCRIPTION:
NOT FOR CONSTRUCTION
DESIGNED:
4/8/2020 2:09:34 PM
M0.1
GENERAL
INFORMATION
Drawn By
Approver
0200100.04
Downtown Transit
Center - Restroom
Upgrades
City of Fort Collins
250 N. Mason St, Fort Collins, CO
04.08.2020
Designer
90% CD
14,957A
1#2/0
X
13,649A
DO NOT TERMINATE
IG CONDUCTOR
IN PANEL P1
(4#3, 1#8G, 1-1/4"C)
(4#4/0, 1#4IG, 1#4G, 2-1/2"C)
LIEBERT AVC
SERIES OR
APPROVED EQUAL
LOAD SUMMARY: P2
EXISTING LOAD: 13400 VA
LOAD REMOVED: 1260 VA
NEW LOAD: 360 VA
TOTAL LOAD: 12500 VA
TOTAL LOAD: 34.72 A
LOAD SUMMARY: P1
EXISTING LOAD: 101400 VA
LOAD REMOVED (P2 AND P3): 1508 VA
NEW LOAD (P2, P3, AND EF-10): 1040 VA
TOTAL LOAD: 100932 VA
TOTAL LOAD: 280.37 A
LOAD SUMMARY: P3
EXISTING LOAD: 21800 VA
LOAD REMOVED: 248 VA
NEW LOAD: 152 VA
TOTAL LOAD: 21704 VA
TOTAL LOAD: 60.29 A
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
ISSUE:
# DATE: DESCRIPTION:
NOT FOR CONSTRUCTION
DESIGNED:
4/8/2020 10:32:48 AM
E1.1
ELECTRICAL PLANS
JPG
APC
0200100.04
Downtown Transit
Center - Restroom
Upgrades
City of Fort Collins
250 N. MASON ST. FORT
COLLINS, CO
04.08.2020
INM
90% CD
0 4 8 16
NORTH
PLAN
B. CONTRACTOR TO CONFIRM THAT ALL EXISTING CIRCUIT CONTINUITY IS MAINTAINED.
A. EXISTING PANNEL/CIRCUIT NUMBERS SHOWN ARE BASED ON EXISTING DRAWINGS.
CONTRACTOR TO CONFIRM THAT INFORMATION SHOWN ON DEMOLITION DRAWINGS
ARE ACCURATE.
GENERAL NOTES
#
SCALE: 1/4" = 1'-0"
2
LIGHTING PLAN
KEYNOTES
1 THIS ROOM IS NOT IN SCOPE OF WORK. ALL EQUIPMENT AND FIXTURES ARE
EXISTING TO REMAIN.
2 DEMOLISH ALL EXISTING ELECTRICAL EQUIPMENT AND LIGHTING FIXTURES IN THIS
SPACE. SEE NEW WORK PLANS E1.1/1 AND E1.1/2 ON THIS SHEET. REUSE EXISTING
CONDUCTORS AND CONDUITS WHERE APPROPRIATE.
3 MOUNT TYPE B FIXTURE HORIZONTALLY AND CENTERED ABOVE MIRROR.
4 CIRCUIT EF-10 TO P1-24. IF CIRCUIT IS NOT AVAILABLE, CIRCUIT TO OPEN SPACE OR
15A/1P SPARE AVAILABLE IN PANEL P1.
SCALE: 1/4" = 1'-0"
1
POWER AND SYSTEMS PLAN
SCALE: 1/4" = 1'-0"
3
ELECTRICAL DEMOLITION PLAN
KEY PLAN
SCALE: NOT TO SCALE
4
EXISTING ONE-LINE DIAGRAM (FOR REFERENCE ONLY)
LUMINAIRE SCHEDULE
TYPE MANUFACTURER CATALOG NUMBER LAMP DESCRIPTION VOLTAGE LOAD (VA) FINISH MOUNTING DESCRIPTION
A PRESCOLITE LC8SL SERIES 3500K, 90+ CRI, LED 120 V 22 WHITE RECESSED 8" DOWNLIGHT, 0-10V DIMMING, 1000 LM
B COLUMBIA LIGHTING CWM SERIES 3500K, LED 120 V 32 WHITE HORIZONTAL
ABOVE
MIRROR
4' VANITY LIGHT, 3240 LM, FROSTED RECTILINEAR LENS,
FLAT ALUMINUM END CAPS, 0-10V DIMMING, WITH
EMERGENCY BATTERY PACK.
B.
FOR APPROVAL OF FIXTURES FROM MANUFACTURERS OTHER THAN THOSE LISTED, PROPOSED FIXTURES SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER TEN BUSINESS DAYS PRIOR TO BID FOR REVIEW. FINAL DETERMINATION
OF
'EQUAL' STATUS FOR BIDDING SHALL BE THE SOLE DETERMINATION OF THE ARCHITECT/ENGINEER.
NOTES: A. REMOVE ALL FINGER PRINTS FROM LENSES, REFLECTORS, AND LOUVERS FOLLOWING LIGHT FIXTURE INSTALLATION.
EQUIPMENT DATA SCHEDULE
DESCRIPTION LOAD DATA DISCONNECT AT EQUIP.
WIRE & CONDUIT REMARKS
MARK EQUIPMENT
FURNISHED BY
INSTALLED BY
LOCATION
LOAD
VOLTAGE
PHASE
DISC. TYPE
DISC. SIZE
FURNISHED BY
INSTALLED BY
EF 10 EXHAUST FAN MC MC ROOF 1/8 HP 120 1 SW -- EC EC 2#12, 1#12G, 3/4"C
N. FIELD ADJUST ALL LUMINAIRES REQUIRING AIMING WITH THE OWNER PRESENT AND TO THEIR
SATISFACTION.
M. THE ELECTRICAL CONTRACTOR SHALL BE HELD FINANCIALLY RESPONSIBLE FOR ANY AND ALL COSTS OF
THE ENGINEERS TIME REQUIRED TO REVIEW AND RESEARCH NON-SPECIFIED EQUIPMENT SUBMITTED
FOR SUBSTITUTION BY THE ELECTRICAL CONTRACTOR. THESE COSTS SHALL BE AUTOMATICALLY
INVOICED TO THE CONTRACTOR UNLESS SUCH SUBSTITUTIONS FOLLOW THE GUIDELINES FOR
SUBSTITUTION AND ARE WITHIN THE PROPER TIME FRAME AS OUTLINED IN OTHER SECTIONS OF THIS
SPECIFICATION.
L. ALL LUMINAIRES WITH EMERGENCY BATTERIES SHALL HAVE THE BATTERY CHARGER CIRCUITED TO THE
AMBIENT LIGHTING CIRCUIT IN THE SPACE BUT SHALL BE UNSWITCHED. IF THE LUMINAIRE IS INDICATED
AS SWITCHED, ONLY THE LUMINAIRE SHALL BE CONTROLLED BY THE SWITCHED CONDUCTORS (BATTERY
CHARGER SHALL REMAIN UNSWITCHED).
K. FINISH OF ALL LIGHTING FIXTURES IS SUBJECT TO ARCHITECT'S APPROVAL. SUBMIT SAMPLES IF
REQUESTED.
J. ALL RECESSED LUMINAIRES IN HARD CEILINGS SHALL HAVE FEED-THRU JUNCTION BOXES.
I. ALL LIGHT FIXTURES SHALL BE EQUIPPED WITH A GREEN GROUND WIRE BONDED TO THE HOUSING.
1. ALL PENETRATIONS OF FIRE-RESISTIVE FLOORS OR SHAFT WALLS SHALL BE PROTECTED BY
MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UNDERWRITERS' LABORATORIES LISTINGS
FOR "THROUGH-PENETRATION FIRE STOP SYSTEMS." THE CONTRACTOR SHALL SUBMIT SHOP
DRAWING DETAILS, FURNISHED BY THE MANUFACTURER OF THE FIRE STOP MATERIAL, WHICH SHOW
COMPLETE CONFORMANCE TO THE UL LISTING AND SHALL BE SPECIFIC FOR EACH PENETRATION WITH
ALL VARIABLES DEFINED. THESE FINAL AND APPROVED DRAWINGS SHALL BE READILY AVAILABLE TO
THE LOCAL INSPECTORS AT ALL TIMES AT THE PROJECT SITE.
H. REFER TO ARCHITECTURAL PLANS TO CONFIRM ALL FIRE-RATED CEILINGS AND WALLS.
G. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR ACTUAL LAYOUT OF LIGHT FIXTURES AND
CEILING TYPES. VERIFY CEILING TYPES PRIOR TO ORDERING FIXTURES.
F. DRAWINGS SHOW EXISTING CONDITIONS OF THE SITE. AN ATTEMPT HAS BEEN MADE TO SHOW EXISTING
BUILDING, SITE DETAILS, ETC., BUT ACCURACY CANNOT BE GUARANTEED. VERIFY EXACT LOCATIONS OF
ALL CIRCUITS, CONDUITS, PIPING, EQUIPMENT, ETC. VERIFY ALL SITE AND BUILDING DETAILS.
E. GROUT AND SEAL ALL CONDUIT PENETRATIONS OF WALLS AND FLOOR SLABS TO PRESERVE FIRE RATING
AND WATERTIGHT INTEGRITY.
D. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY, COORDINATE AND CONFIRM WITH
THE MECHANICAL AND PLUMBING CONTRACTOR THE EXACT LOCATIONS AND FEED REQUIREMENTS OF
ALL EQUIPMENT NEEDING AN ELECTRICAL CONNECTION.
C. SEE MECHANICAL/PLUMBING DRAWINGS FOR ELECTRICAL REQUIREMENTS OF ALL
MECHANICAL/PLUMBING EQUIPMENT, FOR WIRING AND CONTROL DIAGRAMS, AND FOR EXACT LOCATION
OF EQUIPMENT.
B. PRIOR TO ROUGH-IN AND FINAL CONNECTION, VERIFY ELECTRICAL REQUIREMENTS AND EXACT
LOCATION OF EQUIPMENT BEING PROVIDED BY OTHER TRADES. REFERENCE ENTIRE SET OF
CONSTRUCTION DOCUMENTS AS WELL AS FINALIZED SHOP DRAWINGS.
A. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, ELEVATIONS, AND BUILDING DETAILS. VERIFY
LOCATION OF ALL WALL OUTLETS, SWITCHES, ETC., WITH ARCHITECTURAL DRAWINGS AND ACTUAL
CONDITIONS.
COMMON REQUIREMENTS:
I. EXISTING LOW VOLTAGE WIRING WHICH WILL NOT BE MADE OBSOLETE AND WHICH WILL BE DISTURBED
DUE TO CONSTRUCTION CHANGES REQUIRED BY THIS CONTRACT SHALL BE RESTORED TO CONDITION,
OR POSITION, AS REQUIRED. PROPERLY RE-SECURE CABLE IN CHASES, CRAWL SPACES, TUNNELS, AND
CEILING SPACES AS REQUIRED BY NEC. IN SOME CASES IT MAY BE NECESSARY TO ADD SUPPORTING
HARDWARE TO ACCOMPLISH THIS REQUIREMENT.
H. ALL ELECTRICAL CONNECTIONS REQUIRING AN OUTAGE SHALL BE MADE DURING AN APPROVED TIME
LIMIT. CHANGEOVERS SHALL BE AS SHORT A DURATION AS POSSIBLE AND SHALL NOT INTERFERE WITH
NORMAL OPERATION OF THE OWNER'S FACILITIES. NOTICE SHALL BE REQUIRED IN ADVANCE OF A
SHUTDOWN OF ANY ELECTRICAL CIRCUIT FOR CHANGEOVER, AND SUCH A CHANGEOVER SHALL BE DONE
DURING HOURS AS DIRECTED BY OWNER. WORK SHALL BE SCHEDULED SO THAT AT NO TIME WILL ANY
EMERGENCY FEEDER, CIRCUIT, OR FIRE ALARM ZONE BE OUT OF SERVICE. PROVIDE NECESSARY
TEMPORARY FEEDERS TO ACCOMPLISH THIS REQUIREMENT.
G. EXAMINE ARCHITECTURAL, STRUCTURAL, AND MECHANICAL DRAWINGS AND SPECIFICATIONS TO
DETERMINE THE SEQUENCE OF CONSTRUCTION THROUGHOUT THE PROJECT, INCLUDING EXISTING,
TEMPORARY, REMODELED AND NEW AREAS.
F. ALL TEMPORARY AND REMODELING WORK SHALL BE CONSIDERED A PART OF THIS CONTRACT AND NO
EXTRA CHARGES WILL BE ALLOWED. THIS SHALL INCLUDE MINOR ITEMS OF MATERIAL OR EQUIPMENT
NECESSARY TO MEET THE REQUIREMENTS AND INTENT OF THE PROJECT.
E. THE CONTRACTOR SHALL BE HELD FULLY RESPONSIBLE FOR THE PROPER RESTORATION OF ALL
EXISTING SURFACES REQUIRED PATCHING, PLASTERING, PAINTING AND/OR OTHER REPAIR DUE TO THE
INSTALLATION OF ELECTRICAL WORK UNDER THE TERMS OF THIS SPECIFICATION. CLOSE ALL
OPENINGS, REPAIR ALL SURFACES, ETC., AS REQUIRED. THE CONTRACTOR SHALL EMPLOY QUALIFIED
AND EXPERIENCED WORKMEN FOR THIS WORK. ALL RESTORATION WORK SHALL BE SUBJECT TO THE
APPROVAL OF THE ARCHITECT AND/OR THE OWNER.
D. OUTLETS FROM WHICH FIXTURES, SWITCHES, RECEPTACLES, AND/OR OTHER ELECTRICAL DEVICES ARE
MOVED AND WHICH ARE NOT REPLACED OR REUSED SHALL BE REMOVED OR, IF IT IS NOT POSSIBLE TO
REMOVE, PLACE A BLANK COVER ON THE OUTLET BOX. WHERE OUTLETS, BOXES, ETC., ARE
COMPLETELY REMOVED, THE CONTRACTOR SHALL CUT OFF CONDUITS AND REMOVE WIRING.
C. EXISTING ELECTRICAL WIRING WHICH WILL NOT BE MADE OBSOLETE AND WHICH WILL BE DISTURBED
DUE TO CONSTRUCTION CHANGES REQUIRED BY THIS CONTRACT SHALL BE RESTORED TO OPERATING
CONDITION, AS REQUIRED AND/OR DIRECTED. WHERE REQUIRED, SHOWN AND/OR DIRECTED, OUTLETS
AND CONDUIT RUNS SHALL BE RELOCATED. IN SOME CASES IT MAY BE NECESSARY TO EXTEND
CONDUITS AND PULL IN NEW WIRING OR INSTALL JUNCTION BOXES AND SPLICE IN NEW WIRING OR
REPLACE OLD WIRING WITH NEW.
B. BRANCH CIRCUITS SHALL BE REUSED WHERE PRACTICAL AND SHALL, IN ADDITION, BE REMODELED AS
REQUIRED. THE CONTRACTOR SHALL CONCEAL ALL WORK WHERE POSSIBLE. WHERE EXPOSED WORK
IS REQUIRED IN FINISHED AREAS, THE CONTRACTOR SHALL USE WIREMOLD RACEWAY WITH #500 BEING
THE MINIMUM SIZE ACCEPTABLE.
A. CERTAIN RENOVATION OF ELECTRICAL FACILITIES WILL BE REQUIRED IN THE EXISTING BUILDING.
EXISTING CONDUIT RUNS ARE GENERALLY NOT SHOWN, ALTHOUGH A FULL ATTEMPT HAS BEEN MADE TO
SHOW SOME EXISTING CONDITIONS, OF WHICH INFORMATION HAS BEEN TAKEN FROM EXISTING RECORD
DRAWINGS OF THIS PROJECT. THE DRAWINGS SHOWING LOCATION OF EXISTING EQUIPMENT, OUTLETS,
FIXTURES, ETC., IN EXISTING AREAS ARE APPROXIMATE ONLY (FIELD VERIFY).
RENOVATION NOTES:
H. EXISTING EQUIPMENT NOT IMPLICITLY SHOWN ON THE DRAWINGS IS INTENDED TO BE "EXISTING TO
REMAIN UNCHANGED", UNLESS NOTED OTHERWISE.
6. REMOVAL OF FEEDER CONDUIT IF FOUND TO BE UNSALVAGEABLE BY ARCHITECT, ENGINEER OR
OWNER'S REPRESENTATIVE.
5. CAPPING OF FEEDER CONDUIT AT 6" ABOVE OR BELOW FLOOR/CEILING AS REQUIRED AND
MARKING LOCATION OF POINT OF FEED WITH AN ENGRAVED BRASS TAG.
4. PATCHING OF WALLS, FLOORS AND CEILINGS PER ARCHITECT'S INSTRUCTIONS.
3. REMOVAL OF ALL FITTINGS, SUPPORTS, BRACKETS, ETC.
2. REMOVAL OR RE-CIRCUITING OF ALL BRANCH CIRCUITING.
1. REMOVAL OF FEEDER FROM EQUIPMENT TO POINT OF FEED.
G. WORK REQUIRED FOR EXISTING EQUIPMENT NOTED AS "EXISTING TO BE REMOVED" SHALL INCLUDE:
F. MAKE AS-BUILTS WITH NEW TYPED DIRECTORIES FOR ALL PANELBOARDS, INDICATING CIRCUIT
DESCRIPTION (USED OR SPARE), CIRCUIT BREAKERS AND CIRCUIT LOAD.
E. REMOVED OR DAMAGED CONDUIT, WIRE, AND FITTINGS SHALL NOT BE REUSED FOR RELOCATED OR
NEW DEVICES.
D. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK REQUIRED TO REMOVE/RELOCATE
ANY EXISTING ELECTRICAL EQUIPMENT SUCH THAT ELECTRIC SHOCK HAZARDS TO WORKMEN ARE
ELIMINATED DURING DEMOLITION AND NEW CONSTRUCTION.
C. ELECTRICAL CONTRACTOR TO PROVIDE ALL NECESSARY LABOR, CONDUIT, WIRE, CONNECTIONS,
ETC., FOR DEVICES, FIXTURES, ETC., NOTED AS "EXISTING TO REMAIN" SUCH THAT EXISTING CIRCUIT
CONTINUITY IS MAINTAINED.
B. REMOVE ALL EXISTING WIRING DEVICES, LIGHT FIXTURES, WIRE, CONDUIT, ETC., AS NOTED OR
INDICATED WITHIN DEMOLITION AREA. (ALL ITEMS MAY NOT BE SHOWN). REWORK AS NECESSARY
CIRCUITING WHICH REQUIRES CONTINUATION THROUGH THE AREA.
A. RETURN REMOVED MATERIAL DEEMED SALVAGEABLE BY OWNER'S REPRESENTATIVE. MATERIALS
DEEMED NOT SALVAGEABLE SHALL BE REMOVED FROM THE PREMISES.
DEMOLITION:
GENERAL NOTES
A. THE WORK TO BE PERFORMED UNDER THIS DIVISION OF THE SPECIFICATIONS SHALL INCLUDE ALL LABOR,
MATERIALS, EQUIPMENT, TRANSPORTATION, CONSTRUCTION, FACILITIES, AND INCIDENTALS NECESSARY FOR
THE PROPER EXECUTION AND COMPLETION OF ALL ELECTRICAL WORK AS SHOWN AND INDICATED ON THE
CONTRACT DRAWINGS, AND/OR HEREIN SPECIFIED WITH THE INTENT THAT THE INSTALLATION SHALL BE
COMPLETE IN EVERY RESPECT, READY FOR USE. COMPLY WITH THE LATEST EDITION IN FORCE OF THE NFPA
CODES INCLUDING THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL
CODES.
WORK INCLUDED
FIRE ALARM
D. SUBMIT ELECTRONIC COPIES OF OPERATING AND MAINTENANCE MANUAL/RECORD DOCUMENTS.
MANUAL/RECORD DOCUMENTS SHALL CONSIST OF MANUFACTURER'S STANDARD PRODUCT DATA,
MANUFACTURER'S CURRENT PRINTED OPERATING AND MAINTENANCE INSTRUCTION, LIST OF ORIGINAL SPARE
PARTS, LIST OF SUPPLIERS DISTRIBUTING SPARE PARTS, RECOMMENDED QUANTITIES TO BE MAINTAINED IN
STORAGE, TEST REPORTS AS REQUIRED BY CODE (IF SYSTEM REQUIRED), APPROVAL DOCUMENTATION OF THE
AHJ (IF SYSTEM REQUIRED), PROGRAMING INFORMATION STORED ON A FLASH DRIVE (FIRE ALARM ONLY),
PAPER COPIES OF ALL DOCUMENTATION STORED IN THE FIRE ALARM DOCUMENT CABINET (FIRE ALARM ONLY).
MANUAL SHALL INCLUDE INFORMATION ON THE FOLLOWING:
WIRING DEVICES/COVER PLATES
OCCUPANCY/VACANCY SENSORS
LIGHTING
C. SUBMIT ELECTRONIC COPIES OF OPERATING AND MAINTENANCE MANUAL/RECORD DOCUMENTS.
MANUAL/RECORD DOCUMENTS SHALL CONSIST OF MANUFACTURER'S STANDARD PRODUCT DATA,
MANUFACTURER'S CURRENT PRINTED OPERATING AND MAINTENANCE INSTRUCTIONS, LIST OF ORIGINAL SPARE
PARTS, LIST OF SUPPLIERS DISTRIBUTING SPARE PARTS, RECOMMENDED QUANTITIES TO BE MAINTAINED IN
STORAGE AND ALL WARRANTIES. MANUAL SHALL INCLUDE INFORMATION ON THE FOLLOWING:
FIRE ALARM
B. SUBMIT ELECTRONIC COPIES OF PRODUCT DATA, SHOP DRAWINGS, WIRING DIAGRAMS, LAYOUT DRAWINGS ,
BATTERY CALCULATIONS PER CODE (IF SYSTEM REQUIRED), AND NICET CERTIFICATE FOR DESIGN TECHNICIAN
(IF SYSTEM REQUIRED). LITERATURE SHALL BE MARKED TO INDICATE THE SIZE, TYPE OR MODEL BEING
PROPOSED AND ALL ACCESSORIES TO BE PROVIDED:
WIRING DEVICES/COVER PLATES
OCCUPANCY/VACANCY SENSORS
LIGHTING AND LIGHTING CONTROLS
A. SUBMIT ELECTRONIC COPIES OF PRODUCT DATA, SHOP DRAWINGS, WIRING DIAGRAMS AND LITERATURE ON
SYSTEMS INDICATED BELOW. LITERATURE SHALL BE MARKED TO INDICATE THE SIZE, TYPE OR MODEL BEING
PROPOSED AND ALL ACCESSORIES TO BE PROVIDED.
SUBMITTALS
B. THE ELECTRICAL CONTRACTOR SHALL BE HELD FINANCIALLY RESPONSIBLE FOR ANY AND ALL COSTS OF THE
ENGINEER'S TIME REQUIRED TO REVIEW AND RESEARCH NON-SPECIFIED EQUIPMENT SUBMITTED FOR
SUBSTITUTION BY THE ELECTRICAL CONTRACTOR. THESE COSTS SHALL BE AUTOMATICALLY INVOICED TO THE
CONTRACTOR UNLESS SUCH SUBSTITUTIONS FOLLOW THE GUIDELINES FOR SUBSTITUTION AND ARE WITHIN
THE PROPER TIME FRAME AS OUTLINED IN OTHER SECTIONS OF THIS SPECIFICATION.
A. "APPROVED EQUAL" INDICATES THE SPECIFYING ENGINEER SHALL APPROVE ALL CONTRACTOR PROPOSED
ALTERNATE MATERIAL OR MANUFACTURERS. ENGINEER'S DECISION IS FINAL.
GENERAL
B. MANUFACTURER'S WARRANTY ON ALL EQUIPMENT SHALL BE FOR A TIME PERIOD OF ONE (1) YEAR FROM
SUBSTANTIAL COMPLETION UNLESS NOTED OTHERWISE.
A. CONTRACTOR'S WARRANTY ON COMPLETE ELECTRICAL INSTALLATION SHALL BE FOR A TIME PERIOD OF ONE
(1) YEAR FROM SUBSTANTIAL COMPLETION.
WARRANTY
B. COORDINATE INSTALLATION OF SERVICE ENTRANCE THOROUGHLY WITH UTILITY COMPANY. CONTRACTOR
SHALL BE RESPONSIBLE FOR ALL COSTS RELATED TO SERVICE ENTRANCE WORK, INCLUDING ANY CHARGES
FROM THE UTILITY COMPANY.
A. IN GENERAL, COORDINATE WORK THOROUGHLY WITH OTHER TRADES, OWNER AND UTILITY COMPANIES TO
PROVIDE EFFICIENT FLOW OF THE WORK AND TIMELY COMPLETION OF THE CONTRACT.
COORDINATION
C. "APPROVED EQUAL" INDICATES THE SPECIFYING ENGINEER SHALL APPROVE ALL CONTRACTOR PROPOSED
ALTERNATE MATERIAL OR MANUFACTURERS. ENGINEER'S DECISION IS FINAL.
B. IDENTIFICATION: LAMINATED PLASTIC LABELS ON ALL EQUIPMENT, SWITCHES, CONTROLS, ETC.
A. IN GENERAL ALL MATERIALS SHALL BE: NEW, U.L. LISTED FOR THE SPECIFIC APPLICATION AS SPECIFIED OR AS
REQUIRED, AND INSTALLED PER MANUFACTURER'S INSTRUCTIONS.
BASIC MATERIALS
G. PROVIDE CONDUIT SEALING FITTINGS IN ACCORDANCE WITH NEC AND WHERE INDICATED ON DRAWINGS.
LOCATE FITTINGS AT SUITABLE, APPROVED, ACCESSIBLE LOCATIONS AND FILL WITH U.L. LISTED SEALING
COMPOUND. INSTALL SEALING FITTINGS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
F. CONDUIT SHALL BE INSTALLED CONCEALED UNLESS NOTED OTHERWISE ON DRAWINGS.
E. RGS CONDUIT SHALL BE USED IN OUTDOOR EXPOSED LOCATIONS, INDOOR DAMP OR WET LOCATIONS,
HAZARDOUS LOCATIONS, OR WHERE REQUIRED BY NEC AND WHERE NOTED ON DRAWINGS.
D. EMT MAY BE USED WHERE PERMITTED BY NEC EXCEPT WHERE OTHER TYPE IS SPECIFIED HEREIN OR NOTED
ON DRAWINGS.
C. MINIMUM CONDUIT SIZE SHALL BE 3/4".
B. RIGID GALVANIZED STEEL (RGS) CONDUIT: COMPLYING WITH ANSI C80.1, THREADED CONDUIT WITH APPROVED
FITTINGS, SIZED AS SHOWN ON DRAWINGS OR IF NOT SIZED ON THE DRAWINGS, IN ACCORDANCE WITH NEC
AND OTHER APPLICABLE PORTIONS OF THE CONTRACT DOCUMENTS.
A. ELECTRICAL METALLIC TUBING (EMT): COMPLYING WITH ANSI C80.3 WITH COMPRESSION TYPE FITTINGS, SIZED
AS SHOWN ON DRAWINGS OR IF NOT SIZED ON THE DRAWINGS, IN ACCORDANCE WITH NEC AND OTHER
APPLICABLE PORTIONS OF CONTRACT DOCUMENTS.
CONDUIT
4. BE U.L. LISTED AND LABELED FOR THEIR APPLICATION.
3. BE OF PROPER SIZE AND SHAPE FOR CONDUITS ENTERING THEM.
2. BE NEMA TYPE 3R OR NEMA TYPE 4 FOR INDOOR DAMP OR WET LOCATIONS AND OUTDOOR LOCATIONS.
1. BE NEMA TYPE 1 FOR INDOOR DRY LOCATIONS.
B. ALL PULL/JUNCTION BOXES AND ENCLOSURES SHALL:
4. BE CAST TYPE FOR EXPOSED WORK BELOW 10'-0" AFF.
3. BE U.L. LISTED AND NEC RATED FOR THEIR APPLICATION.
2. BE OF PROPER SIZE AND SHAPE FOR CONDUITS ENTERING THEM.
1. BE STAMPED, ONE PIECE, GALVANIZED STEEL.
A. ALL STANDARD INTERIOR OUTLET BOXES SHALL:
BOXES
E. MC CABLE SHALL NOT BE USED EXCEPT FOR FIXTURE WHIPS.
D. ALL CONDUCTORS FOR BRANCH CIRCUITS SHALL BE COPPER.
C. ALL CONDUCTORS SIZE #10 AND SMALLER SHALL BE SOLID COPPER. CONDUCTORS SIZE #8 AND LARGER SHALL
BE STRANDED.
B. ALL CONDUCTORS SHALL BE COLOR CODED WITH WIRE LABELS INSTALLED FOR EASY IDENTIFICATION.
A. ALL CONDUCTORS SHALL BE COPPER, 600 VOLT, TYPE THHN/THWN UNLESS OTHERWISE NOTED. MINIMUM WIRE
SIZE SHALL BE #12 AWG FOR POWER WIRING AND #14 AWG FOR CONTROL WIRING.
WIRE AND CABLES
A. ALL CONNECTORS SHALL BE OF MATERIAL COMPATIBLE WITH THE MATERIAL OF THE CONDUCTORS TO
PREVENT CORRODING, DIFFERENCES IN COEFFICIENTS OF EXPANSION AND ELECTROLYSIS AS MANUFACTURED
BY IDEAL, BURNDY, THOMAS AND BETTS, AND 3-M.
WIRE CONNECTIONS AND DEVICES
WIRE COLOR CODE FOR 120/208V, 3Ø, 4W
PHASE A: BLACK
PHASE B: RED
PHASE C: BLUE
NEUTRAL: WHITE
GROUND: GREEN
WIRE COLOR CODE FOR 480V
PHASE A: BROWN
PHASE B: ORANGE
PHASE C: YELLOW
NEUTRAL: GRAY
GROUND: GREEN
D. WIRE SHALL BE COLOR CODED IN INDUSTRY STANDARD FORMAT, COLORED CONDUCTOR OR COLORED TAPE
WRAPPING.
C. RECEPTACLES SHALL HAVE ENGRAVED COVER PLATES IDENTIFYING THE PANEL AND CIRCUIT NUMBER.
B. ALL PANELBOARDS SHALL BE PROVIDED WITH A TYPEWRITTEN CIRCUIT DIRECTORY, LAMINATED AND MOUNTED
INSIDE THE PANEL COVER.
A. ALL PANELBOARDS, SWITCHBOARDS, DISCONNECT DEVICES, CONTROLLERS, ETC., SHALL BE PROVIDED WITH A
WHITE NAMEPLATE WITH BLACK ENGRAVED LETTERS MOUNTED IN A VISIBLE LOCATION ON THE DEVICE. PLATE
SHALL INDICATE THE DEVICE TAG, THE SOURCE OF POWER AND THE CIRCUIT NUMBER.
IDENTIFICATION
c. PASS & SEYMOUR/LEGRAND #2097W
b. LEVITON #N7899
a. HUBBELL #GFST20
GFCI RECEPTACLE
c. PASS & SEYMOUR/LEGRAND #5362
b. LEVITON #5362
a. HUBBELL #HBL 5362
20 AMP, STRAIGHT BLADE, NEMA 5-20R
4. APPROVED PRODUCTS:
3. COVERPLATES SHALL BE HIGH IMPACT, SMOOTH NYLON TYPE; COLOR SHALL MATCH WIRING DEVICE
UNLESS NOTED OTHERWISE.
2. SNAP SWITCHES SHALL BE QUIET-TYPE; COMPLYING WITH U.L. STANDARD 20 AND FEDERAL SPECIFICATION
W-S-896.
1. RECEPTACLES SHALL BE NEMA 5-20, STRAIGHT BLADE, GROUNDING TYPE, COMPLYING WITH FEDERAL
SPECIFICATION WC-596F.
A. WIRING DEVICES SHALL BE U.L. LISTED, HEAVY DUTY INDUSTRIAL GRADE TYPE, 1. COMPLYING WITH NEMA
STANDARD WD 1. COLOR SHALL BE DETERMINED BY THE DESIGN PROFESSIONAL DURING SHOP DRAWINGS.
WIRING DEVICES
1. MATCH EXISTING.
D. APPROVED MANUFACTURERS:
1. SYSTEMS SHALL MATCH EXISTING SYSTEM IN BUILDING.
B. CEILING MOUNTED SYSTEMS
A. LIGHTING SYSTEM CONTROLS ARE DIAGRAMMATIC AND ARE GENERIC. SUCCESSFUL LIGHTING CONTROL
SYSTEM VENDOR SHALL THOROUGHLY EXAMINE PLANS AND SHALL PROVIDE CONTRACTOR WITH DETAILED
LAYOUT DRAWINGS AND BILL OF MATERIALS TO PROVIDE A COMPLETE AND OPERATIONAL SYSTEM WITHOUT
REQUESTS FOR ADDITIONAL MONETARY COMPENSATION FOR "MISSING" COMPONENTS.
OCCUPANCY/VACANCY SENSORS
F. PROVIDE "BLACK-OUT" TEST OF EMERGENCY LUMINAIRES UPON PROJECT COMPLETION IN THE PRESENCE OF
THE AUTHORITY HAVING JURISDICTION.
E. CORRECT WIRING DEFICIENCIES AND REPAIR OR REPLACE DAMAGED OR DEFECTIVE PRODUCTS. REPAIR OR
REPLACE EXCESSIVELY NOISY BALLASTS AS DETERMINED BY ARCHITECT.
D. TEST SELF-POWERED EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND FLUORESCENT EMERGENCY POWER
SUPPLY UNITS TO VERIFY PROPER OPERATION UPON LOSS OF NORMAL POWER SUPPLY.
C. OPERATE EACH LUMINAIRE AFTER INSTALLATION AND CONNECTION TO VERIFY PROPER OPERATION.
B. INSPECT EACH PRODUCT FOR DAMAGE AND DEFECTS.
A. SEE SECTION 01 4000 - QUALITY REQUIREMENTS FOR ADDITIONAL REQUIREMENTS.
FIELD QUALITY CONTROL
A. PERFORM COMPLETE OPERATIONAL TEST OF ELECTRICAL INSTALLATION BEFORE ACCEPTANCE BY OWNER.
TEST SHALL BE PERFORMED IN PRESENCE OF OWNER'S REPRESENTATIVE.
TESTING
B. SEE LUMINAIRE SCHEDULE ON DRAWINGS FOR DESCRIPTION.
2. FURNISHED WITH 6'-0" OF FLEXIBLE CONDUIT PREWIRED (DROP IN ONLY). BE U.L. LISTED IN ACCORDANCE
WITH THE NEC.
1. FURNISHED WITH PROPER OUTLET BOXES, HANGERS, HARDWARE, SUPPORTS, CANOPY EXTENSIONS,
PLUGS.
A. LUMINAIRES SHALL BE:
LIGHTING
J. SUBMIT A CERTIFICATE OF COMPLETION PER NFPA 72.
I. PROVIDE DEMONSTRATION OF THE MODIFIED FIRE ALARM SYSTEM TO THE OWNER. PERFORM ALL THE
FUNCTIONS SPECIFIED.
H. BEFORE REQUESTING FINAL APPROVAL OF THE INSTALLATION, THE INSTALLING CONTRACTOR SHALL FURNISH
A WRITTEN STATEMENT TO THE EFFECT THAT THE SYSTEM HAS BEEN INSTALLED AND TESTED IN ACCORDANCE
WITH THE MANUFACTURER'S SPECIFICATIONS AND THE APPROPRIATE NFPA REQUIREMENTS.
G. FIRE ALARM SYSTEM MODIFICATIONS AND EXPANSION SHALL BE INSTALLED AND FULLY TESTED UNDER THE
SUPERVISION OF A MANUFACTURER'S SPECIFICATIONS AND THE APPROPRIATE NFPA REQUIREMENTS.
REPORTS OF ALL TESTING DURING INSTALLATION SHALL BE SUBMITTED TO THE OWNER AND ENGINEER UPON
REQUEST.
F. NEW AUDIBLE/VISUAL ALARM DEVICES SHALL BE 100% COMPATIBLE WITH THE EXISTING FIRE ALARM CONTROL
PANEL; SHALL COMPLY WITH ADA REQUIREMENTS; SHALL BE LISTED AND LABELED PER U.L. STANDARD 1971;
AND UL 464 15CD TYPE STROBE, UNLESS NOTED OTHERWISE. SURFACE MOUNT DEVICES AT 80" ABOVE
FINISHED FLOOR OR AT 6" BELOW CEILING, WHICHEVER IS LOWER. PROVIDE ASSOCIATED BACKBOX.
E. NEW VISUAL ALARM DEVICES SHALL BE 100% COMPATIBLE WITH THE EXISTING FIRE ALARM CONTROL PANEL;
SHALL COMPLY WITH ADA REQUIREMENTS; SHALL BE LISTED AND LABELED PER U.L. STANDARD 1971; 15CD
TYPE STROBE, UNLESS OTHERWISE NOTED. SURFACE MOUNT DEVICES AT 80" ABOVE FINISHED FLOOR OR AT
6" BELOW CEILING WHICHEVER IS LOWER. PROVIDE ASSOCIATED BACKBOX.
D. ALL WIRING SHALL BE VERIFIED WITH FIRE ALARM EQUIPMENT SUPPLIER AS TO QUANTITY, SIZE, ROUTING,
CONDUIT, JUNCTION BOX REQUIREMENTS, ETC.
C. PROVIDE HARDWARE AND PROGRAMMING MODIFICATIONS REQUIRED TO THE EXISTING ALARM CONTROL
PANEL AND ASSOCIATED ACCESSORIES TO EXPAND THE EXISTING SYSTEM AS INDICATED ON THE DRAWINGS.
ALL MODIFICATIONS SHALL BE COMPLETE BY MANUFACTURER'S AUTHORIZED TECHNICIAN.
B. ALL NEW WIRING SHALL BE 100% COMPATIBLE WITH EXISTING FIRE ALARM SYSTEM AND SHALL BE AS
DIRECTED BY THE MANUFACTURER OF THE EXISTING FIRE ALARM SYSTEM.
A. ALL DEVICES AND EQUIPMENT ADDED TO THE EXISTING FIRE ALARM SYSTEM SHALL BE 100% COMPATIBLE WITH
THE EXISTING SYSTEM. ALL NEW DEVICES AND EQUIPMENT SHALL BE U.L. LISTED AND SHALL CONFORM TO
NFPA 72.
EXISTING FIRE ALARM SYSTEM
EMERGENCY POWER SYSTEM OR
BALLAST/DRIVER
LUMINAIRE TYPE
PANEL NAME
LUMINAIRE - RECESSED (REFER TO LUMINAIRE SCHEDULE)
CONNECTED FOR NIGHT LIGHT USE
1LP-1a NL
CIRCUIT NUMBER AND SWITCH LEG
(LUMINAIRES ARE CONTROLLED BY LOCAL
SWITCH UNLESS DESIGNATION GIVEN)
A
SPECIAL SYSTEMS
HANDICAP DOOR OPERATORS - SEE ARCHITECURALS WITH 3/4" CONDUIT
a
WALL MOUNTED LUMINAIRE
T-1
45 KVA 3Ø
208Y/120VAC
# AF
# AT
# A
# A
75
75
C
75
C
75
75
C
G
ST
GROUND FAULT
PROTECTED BREAKER
SHUNT TRIP BREAKER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
# AF DRAWOUT CIRCUIT BREAKER
# AT
FUSE
PANELBOARD
1
Room name
101A
PLUMBING EQUIPMENT CALL-OUT: REFER TO
THE EQUIPMENT DATA SCHEDULE FOR DETAILS
J
J
M
G
# A
# POLES
PANEL
###
F
J
DUPLEX RECEPTACLE (NEMA 5-20R) - MOUNTED 18" AFF
GFI GROUND FAULT CIRCUIT INTERRUPTER
SS SURGE SUPPRESSOR (ISOLATED GROUND TYPE)
WP WEATHERPROOF
HG HOSPITAL GRADE
TR TAMPER RESISTANT
D DEDICATED
USB STANDARD DUPLEX WITH 2 USB PORTS
FLOOR BOX - SEE SPECS OR KEYED NOTES ON
PLAN FOR DETAILS
TOGGLE SWITCH - MOUNTED 48" AFF
b LOWER CASE LETTER DENOTES LTG. SWITCH GROUP
2 DOUBLE-POLE SINGLE-THROW (DPST)
3 3-WAY
4 4-WAY
B PUSHBUTTON
D DIMMER (WALL BOX TYPE)
K KEY OPERATED
M MANUAL MOTOR STARTER
P PILOT LIGHT
T TIMER
TT THERMAL TRIP SWITCH
WP WEATHERPROOF
OS WALL BOX OCCUPANCY SENSOR
OS2 WALL BOX OCCUPANCY SENSOR FOR TWO LEVEL
SWITCHING
VS WALL BOX VACANCY SENSOR
LV LOW VOLTAGE SWITCH
TC TEACHER CONTROLS STATION
TE TEACHER ENTRY STATION
MC MOMENTARY CONTACT SWITCH
OS CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR
a LOWER CASE LETTER DENOTES LTG. SWITCH GROUP
NOTIFICATION APPLIANCE MOUNTED 80" AFF OR 6" FROM
CEILING WHICHEVER IS LOWER
C CHIME
H HORN
LF LOW FREQUENCY
NOTIFICATION APPLIANCE - STROBE ONLY
MOUNTED 80" AFF
CANDELA VALUE AS SHOWN MINIMUM
NOTIFICATION APPLIANCE WITH STROBE MOUNTED 80" AFF
OR 6" FROM CEILING WHICHEVER IS LOWER
CANDELA VALUE AS SHOWN MINIMUM
C CHIME
H HORN
LF LOW FREQUENCY
NOTIFICATION APPLIANCE (CEILING)
C CHIME STROBE
H HORN STROBE
LF LOW FREQUENCY
CANDELA VALUE AS SHOWN MINIMUM
CEILING MOUNTED COMBINATION VOICE EVACUATION
SPEAKER AND STROBE
CANDELA VALUE AS SHOWN MINIMUM
COMBINATION VOICE EVACUATION SPEAKER AND STROBE
MOUNTED AT 80" AFF
CANDELA VALUE AS SHOWN MINIMUM
F
CO
S
S
a
VS CEILING MOUNTED DUAL TECHNOLOGY VACANCY SENSOR
a LOWER CASE LETTER DENOTES LTG. SWITCH GROUP
RTS REMOTE TEST SWITCH
GROUND BAR
100A4G
# KVA/KW
480Y/277V, 3Ø, 4W
AHU
1
GWH1
1
#
C ENCLOSED CIRCUIT BREAKER
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
ISSUE:
# DATE: DESCRIPTION:
NOT FOR CONSTRUCTION
DESIGNED:
4/8/2020 10:32:47 AM
E0.1
GENERAL
INFORMATION
JPG
APC
0200100.04
Downtown Transit
Center - Restroom
Upgrades
City of Fort Collins
250 N. MASON ST. FORT
COLLINS, CO
04.08.2020
INM
90% CD
SYMBOLS LEGEND
NOTE: NOT ALL SYMBOLS ARE USED IN CONSTRUCTION DOCUMENTS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MCP MOTOR CIRCUIT PROTECTOR
MDF MAIN DISTRIBUTION FRAME
MDP MAIN DISTRIBUTION PANEL
MEPFP MECHANICAL, ELECTRICAL, PLUMBING,
FIRE PROTECTION
MGB MASTER GROUND BAR
MH MANHOLE
MH METAL HALIDE
MIN MINIMUM
MLO MAIN LUG ONLY
MOCP MAXIMUM OVERCURRENT PROTECTION
MSB MAIN SWITCHBOARD
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MVA MEGAVOLT-AMPERES
MW MEGAWATT
MWH MEGAWATT-HOURS
N NEUTRAL
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NF NONFUSED
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NP NAMEPLATE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OWN OWNER
P POLE
PA PUBLIC ADDRESS
PB PULL BOX
PC PHOTOCELL
PC PLUMBING CONTRACTOR
PF POWER FACTOR
PH PHASE
PIR PASSIVE INFRARED
PLC PROGRAMMABLE LOGIC CONTROLLER
PNL PANEL
PR PAIR
PRI PRIMARY
PT POTENTIAL TRANSFORMER
PV PHOTOVOLTAIC
PVC POLYVINYL CHLORIDE
PWC PRE-WIRED CONTROLS
PWR POWER
RCPT RECEPTACLE
REQD REQUIRED
RF RADIO FREQUENCY
RM ROOM
RMC RIGID METAL CONDUIT
RNC RIGID NON-METALLIC CONDUIT (SCH 40)
RVAT REDUCED VOLTAGE -
AUTOTRANSFORMER
SC SHORT CIRCUIT
SCC SHORT CIRCUIT CURRENT RATING
SDP SUBDISTRIBUTION PANEL
SEC SECONDARY
SHLD SHIELD(ED) (AS IN CABLE)
SHT SHEET
SPD SURGE-PROTECTIVE DEVICE
SPDT SINGLE POLE DOUBLE THROW
SPST SINGLE POLE SINGLE THROW
SR SINGLE RECEPTACLE
ST SHUNT TRIP
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TBD TO BE DETERMINED
TC TIMECLOCK
TCC TEMPERATURE CONTROLS
CONTRACTOR
TEMP TEMPERATURE
TT THERMAL TRIP SWITCH
TTB TELEPHONE TERMINAL BOARD
TYP TYPICAL
U UTILITY
UG UNDERGROUND
UL UNDERWRITERS LABORATORY
UON UNLESS OTHERWISE NOTED
UPS UNINTERUPTABLE POWER SUPPLY
V VOLTS
VA VOLT-AMPERES
VAC VOLTS ALTERNATING CURRENT
VDC VOLTS DIRECT CURRENT
VFD VARIABLE FREQUENCY DRIVE
VND VENDOR
W WATTS
W WIRE
WHM WATTHOUR METER
WP WEATHERPROOF
XFMR TRANSFORMER
XP EXPLOSION PROOF
%Z IMPEDANCE
(E) EXISTING (ALSO COVERED BY TEXT
WEIGHT)
(F) FUTURE
(PART) PARTIAL CIRCUIT
(R) RELOCATE
A AMPERES
AC 6" ABOVE COUNTER
ADA AMERICANS WITH DISABILITIES ACT
AF AMPERES FRAME
AFCI ARC FAULT CIRCUIT INTERRUPTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERES INTERRUPTION CAPACITY
AL ALUMINUM
AT AMPERES TRIP
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAUGE
BMS BUILDING MANAGEMENT SYSTEM
C CONDUIT
CAM CAMERA
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTER CLOCKWISE
CKT CIRCUIT
CL CENTER LINE
CLG CEILING
CO CONDUIT ONLY
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CU COPPER
CW CLOCKWISE
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DPDT DOUBLE POLE DOUBLE THROW
DPST DOUBLE POLE SINGLE THROW
DR DUPLEX RECEPTACLE
DWG DRAWING(S)
EC ELECTRICAL CONTRACTOR
ELC ELEVATOR CONTRACTOR
ELEC ELECTRIC/ELECTRICAL
EM EMERGENCY
EMT ELECTRICAL METALLIC TUBING
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXP EXPLOSION PROOF
F FUSED
FA FIRE ALARM
FAA FIRE ALARM ANNUNCIATOR
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FLA FULL LOAD AMPERES
FMC FLEXIBLE METAL CONDUIT
FO FIBER OPTIC
FPC FIRE PROTECTION CONTRACTOR
FS FUSED SWITCH
FSD FIRE/SMOKE DAMPER
FT FOOT/FEET
FVNR FULL VOLTAGE, NON-REVERSING
FVR FULL VOLTAGE, REVERSING
G GROUND
GC GENERAL CONTRACTOR
GEN GENERATOR
GF GROUND FAULT
GFI/GFCI GROUND FAULT INTERRUPTER
GND GROUND/GROUNDING
H HORIZONTALLY MOUNTED
HH HANDHOLE
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTO
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HZ FREQUENCY
I/O INPUT/OUTPUT
ID INSIDE DIAMETER
IDF INTERMEDIATE DISTRIBUTION FRAME
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
ISC SHORT CIRCUIT CURRENT
JB JUNCTION BOX
K KELVIN (COLOR TEMPERATURE)
KCMIL 1000 CIRCULAR MILS
KV KILOVOLTS
KVA KILVOLT-AMPERES
KW KILOWATTS
KWH KILOWATT-HOUR
LAN LOCAL AREA NETWORK
LC LIGHTING CONTACTOR
LCP LIGHTING CONTROL PANEL
LED LIGHT EMITTING DIODE
LF LINEAR FOOT
LFMC LIQUID-TIGHT FLEXIBLE METAL CONDUIT
LM LUMEN
LTG LIGHTING
LV LOW VOLTAGE
MAN MANUAL MOTOR STARTER WITH
OVERLOADS
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPERES
ABBREVIATIONS
COORDINATE WITH NEW CONSTRUCTION
B. ALL ITEMS INDICATED TO BE DEMOLISHED SHALL BE REMOVED AS TO FULLY
ALLOW FOR THE PROPER FURNISHING AND INSTALLATION OF ALL SCHEDULED
NEW WORK. THIS SHALL INCLUDE DEMOLITION OF ADJACENT ITEMS,
ACCESSORIES, AND APPURTENANCES AS NECESSARY.
C. DEMOLITION DRAWINGS ILLUSTRATE MAJOR ITEMS TO BE REMOVED.
CONTRACTOR SHALL COORDINATE THESE DRAWINGS WITH NEW WORK
DRAWINGS AND SHALL BE RESPONSIBLE FOR OTHER ITEMS REQUIRED TO BE
DEMOLISHED TO ACCOMMODATE NEW WORK.
D. THE CONTRACTOR IS RESPONSIBLE FOR RETAINING AND RELOCATING ALL
SALVAGE AS DESIGNATED BY THE OWNER'S REPRESENTATIVE.
E. PROTECT ALL FINISHES TO REMAIN FROM DAMAGE DURING DEMOLITION AND
CONSTRUCTION.
F. PRIOR TO DEMOLITION, ENSURE THE STABILITY OF ANY WALLS TO REMAIN.
G. REMOVE CEILINGS INCLUDING, BUT NOT LIMITED TO, RELATED SUPPORT
SYSTEMS, CEILING TILES, LIGHT FIXTURES, GRILLES, DIFFUSERS, EXIST SIGNS,
AND OTHER ELECTRICAL OR COMMUNICATION DEVICES.
H. DEMOLITION OF FLOOR FINISHES INCLUDES REMOVAL OF ADHESIVES, GROUTING
BEDS, RESILIENT BASE, ETC.
I. REMOVAL OF EXISTING PLUMBING FIXTURES TO INCLUDE PIPING, WASTE LINES,
ETC. LINES ARE TO BE CAPPED AS REQUIRED. SEE PLUMBING DRAWINGS.
J. REMOVAL OF EXISTING HVAC TO INCLUDE DUCTWORK, HANGERS, GRILLES,
DIFFUSERS, ETC. SEE MECHANICAL DRAWINGS.
K. REMOVAL OF EXISTING ELECTRICAL SYSTEMS TO INCLUDE CONDUIT, BOXES,
WIRE, CABLE, SUPPORTS, WIRING DEVICES, SAFETY SWITCHES, FIRE ALARM
EQUIPMENT, SPEAKERS, TELEPHONE OUTLETS AND LIGHT FIXTURES. SEE
ELECTRICAL DRAWINGS.
DEMOLITION GENERAL NOTES
A. CONTRACTOR TO PROVIDE ALL ADDITIONAL FRAMING NECESSARY FOR ALL
OPENINGS AND SUPPLEMENTAL FRAMING ABOVE PARTITIONS.
B. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES FOR SYSTEM RELATED
PENETRATIONS NOT SHOWN.
C. CONTRACTOR SHALL MAINTAIN THE BUILDING IN A WEATHERPROOF CONDITION
AT ALL TIMES.
D. PROJECTS SHALL REMAIN IN COMPLIANCE WITH ALL ASPECTS OF ALL
GOVERNING CODES AND ORDINANCES DURING THE COURSE OF
CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, EXITING, FIRE ALARM
SYSTEM(S) SMOKE/FIRE DETECTION SYSTEM(S), SPRINKLER SYSTEM(S).
E. TEMPORARY BARRICADES AS PERTAINING TO CONTRACTOR'S ACTIVITIES SHALL
BE INSTALLED TO PREVENT POSSIBLE INJURY TO PERSONS IN AND AROUND
DEMOLITION AND CONSTRUCTION AREAS IN ACCORDANCE WITH OSHA
REQUIREMENTS. COORDINATE WITH OWNER.
F. ALL AREAS TO BE DEMOLISHED OR DISTURBED BY ANY DEMOLITION ARE TO BE
PATCHED AND PAINTED (OR PREPARED FOR OTHER SCHEDULED FINISH). IF
PAINTING IS REQUIRED, ENTIRE WALL SHALL RECEIVE PAINT TO AVOID
MISMATCH OF COLOR.
G. ALL OPENINGS AND VOIDS LEFT BY THE REMOVAL OF EXISTING CONSTRUCTION,
EQUIPMENT, PIPING, DUCTS, ETC, SHALL BE PROPERLY PATCHED AND CLOSED
OFF TO MAINTAIN PROPER FIRE RATING IN AFFECTED WALL, FLOOR, OR ROOF.
PREPARE PATCHED AREAS TO RECEIVE NEW FINISHES AS SCHEDULES (OR
MATCH EXISTING FINISHES IF NOT OTHERWISE IDENTIFIED).
H. WHEN PATCH OF EXISTING FLOOR IS REQUIRED, SLOPING OR RAMPING IN
EXCESS OF CONTRACT TOLERANCES WILL NOT BE ALLOWED (1/8" PER 10 FEET
MAXIMUM).
I. UPON REMOVAL OF TEMPORARY PARTITIONS, CONTRACTOR IS RESPONSIBLE
FOR PATCHING TO MATCH EXISTING ADJACENT CONSTRUCTION.
J. AT CONSTRUCTION ACCESS, CONTRACTOR TO PROVIDE LABOR AND MATERIALS
TO REPAIR ALL DISTURBED ELEMENTS.
K. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO PROVIDE COMPLETE
WORKING SYSTEMS FOR ALL NEW ELEMENTS AND TO COORDINATE THEIR
WORK WITH ALL OTHER TRADES.
L. ALL CONTRACTORS SHALL PROVIDE NEW, UNDAMAGED MATERIALS UNLESS
OTHERWISE SPECIFIED.
M. STORE MATERIALS IN SUCH A MANNER AS NOT TO OVERSTRESS, OVERLOAD, OR
OTHERWISE PUT AN UNSAFE LOAD ON ANY STRUCTURE DURING
CONSTRUCTION.
N. INSTALL ALL WORK IN ACCORDANCE WITH CURRENT APPLICABLE CODES,
PUBLISHED STANDARDS, AND ACCEPTABLE CONSTRUCTION STANDARDS.
O. DETAILS ARE GENERALLY TYPICAL AND ARE NOT TO BE CONSTRUED AS LIMITED
TO THOSE AREAS SPECIFICALLY INDICATED. REVIEW ANY QUESTIONS OR
CONFLICTING INFORMATION WITH THE DESIGN PROFESSIONAL PRIOR TO
FABRICATION OR INSTALLATION.
P. CONTRACTOR SHALL VERIFY DIMENSIONS IN FIELD PRIOR TO BEGINNING
CONSTRUCTION.
Q. HINGE SIDE OF DOOR JAMBS TO BE LOCATED 4” FROM NEAREST WALL
INTERSECTION UNLESS OTHERWISE NOTED.
GENERAL NOTES
1-1/2"
DIAMETER
GRAB BAR
TOILET
TISSUE
DISPENSER
SANITARY
NAPKIN
DISPOSAL
TOILET
FIXTURE
TOILET
FIXTURE
TOILET
TISSUE
DISPENSER
1-1/2"
DIAMETER
GRAB BAR
EXPOSED
PLUMBING AT
BARRIER
FREE
LAVATORIES
SHALL BE
INSULATED.
LEVER OPERATING
CONTROLLED
SOAP DISPENSER
NOTE: SINKS IN COUNTERS TO BE
MOUNTED WITH RIM NO MORE
THAN 2'-10" HIGH AND WITH AT
LEAST 2'-3" KNEE CLEARANCE.
CLEAR
ACCESSIBLE TOILET TYPICAL ACCESSIBLE
CLEARANCE AT LAVATORY
TYPICAL ACCESSIBLE
LAVATORY AND MIRROR
1'-3" 1'-3"
2'-5" MIN
2'-10" MAX
3'-4" MAX
4'-0" MAX
6'-8" A.F.F.
1'-6"
17" - 19"
5'-0" CLEAR
3'-0" 6"
17" - 19"
3'-0" MAX
3'-4" 1'-6"
1'-0" 3'-6"
2'-4"
5'-0" CLEAR
MIN
8"
MAX
6"
MIN
9"
2'-3" MIN
2'-5" MIN
2'-10" MAX
17" MIN
TO BOTTOM OF
REFLECTIVE
SURFACE OF
MIRROR
7"-9"
PAPER TOWEL DISPENSER/
WASTE RECEPTICLE
4'-0"
PAPER TOWEL
DISPENSER
4'-0"
2'-0" AT SIDEWALLS
AT COUNTER SINKS
1'-6" AT SIDEWALLS
AT LAVATORY
FINISH FLOOR
SEAL GAP @ GYP. BD.
TO FLOOR CONDITION
BASE - REFER TO FLOOR
PLAN KEYNOTES
SEE INTERIOR ELEVATIONS
FURTHER FINISH INFORMATION
3 5/8" GALVANIZED LIGHT
GAUGE METAL STUDS @
16" O.C. W/ CONTINUOUS
STIFFENER CHANNEL
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
GYPSUMBOARD CEILING @
8'-6" A.F.F.
ACOUSTICAL JOINT SEALANT
1
1A GYPSUM WALLBOARD ONE SIDE ONLY
2'-6"
LIGHTGAGE BOXBEAM
HEADER
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10
DATE:
DRAWN:
REVIEWED:
SHEET TITLE:
SHEET NUMBER:
PROJECT NO.:
PROJECT:
ISSUE:
# DATE: DESCRIPTION:
NOT FOR CONSTRUCTION
DESIGNED:
3/30/2020 11:07:24 AM
A1.1
DEMO AND NEW
FLOOR PLAN, NOTES,
AND DETAILS
JMS
JMS
0200100.04
Downtown Transit
Center - Restroom
Upgrades
City of Fort Collins
Enter address here
03.30.2020
JMS
Preliminary
SCALE: 1/4" = 1'-0"
2
FLOOR PLAN
#.#
KEY PLAN
SCALE: 1/4" = 1'-0"
1
DEMOLITION FLOOR PLAN
SCALE: 1/4" = 1'-0"
3
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
4
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
5
INTERIOR ELEVATION
DEMOLITION KEYNOTES (BY DIVISION)
DIVISION 06
D6-1 REMOVE EXISTING CASEWORK AND/OR COUNTERTOP
DIVISION 08
D8-1 REMOVE EXISTING DOOR FRAME, AND HARDWARE AS REQUIRED FOR NEW
WORK
DIVISION 09
D9-1 REMOVE EXISTING STUD WALL ASSEMBLY AS REQUIRED FOR NEW WORK
D9-2 REMOVE EXISTING CEILING ASSEMBLY AS REQUIRED FOR NEW WORK
D9-3 REMOVE EXISTING FLOORING AS REQUIRED FOR NEW WORK
TOILET ACCESSORY SCHEDULE
MARK DESCRIPTION
T1 GRAB BAR (42")
T2 GRAB BAR (36")
T3 GRAB BAR (18")
T4 TOILET TISSUE DISPENSER
T5 PAPER TOWEL DISPENSER
T6 SOAP DISPENSER - WALL MOUNTED
T7 MIRROR UNIT (3'-8" T x 2'-0" W)
T8 SEMI-RECESSED PAPER TOWEL DISPENSER / WASTE
RECEPTACLE
T9 UNDERLAVATORY GUARD
SCALE: 3/8" = 1'-0"
STANDARD MOUNTING HEIGHTS
DOOR SCHEDULE
DOOR DOOR FRAME
LBL
HDWR
NO. WIDTH HEIGHT THICK MAT'L FINISH ELEV MAT'L FINISH SET NOTES
T/ SLAB
101 3' - 0" 7' - 0" 1 3/4" WD PF F HM PNT 01
102 3' - 0" 7' - 0" 1 3/4" WD PF F HM PNT 01
HARDWARE SET 01
2 HINGES
1 ELECTRIFIED HINGE
1 LOCKSET (PRIVACY)
1 CLOSER
1 KICKPLATE
1 CARD READER
SILENCERS
KEYNOTES (BY DIVISION)
DIVISION 00
#.#
DIVISION 09
9-1 TILE FLOOR ASSEMBLY
9-2 GYPSUM BOARD CEILING ASSEMBLY - PAINT (SEMI-GLOSS)
9-3 PAINT GYPSUM BOARD ABOVE WALL TILE (SEMI-GLOSS)
9-4 GYPSUM BOARD AND METAL STUD WALL ASSEMBLY INFILL - MATCH ADJACENT
FINISH
9-5 NEW RUBBER BASE TO MATCH EXISTING. PAINT GYPSUMBOARD
SCALE: 3/4" = 1'-0"
PARTITION TYPES