Loading...
HomeMy WebLinkAboutCORRESPONDENCE - PURCHASE ORDER - 9200988A. ALL DIMENSIONS ARE TO FACE OF STUD, CMU AND/OR CONCRETE UNLESS NOTED OTHERWISE. B. ALL NEW WORK SHALL BE PLUMB TRUE, AND LEVEL UNLESS OTHERWISE NOTED. C. DISSIMILAR FLOOR MATERIALS SHALL MEET UNDER CENTER OF DOOR LEAF. D. U.N.O. ALL PAINTED SURFACES TO RECEIVE A MINIMUM OF ONE (1) PRIMER COAT AND THEN TWO (2) FINISH PAINT COATS. a. WALL SURFACES: EGG SHELL (SATIN) NON-RESTROOM AREAS b. WALL SURFACES: SEMI-GLOSS - RESTROOM AREAS c. HOLLOW METAL DOOR FRAME: SEMI-GLOSS E. U.N.O. ALL EXPOSED STRUCTURE, DUCT WORK, PIPING & CONDUITS TO BE PAINTED. PLAN GENERAL NOTES 3 A1.1 5 4 101 102 4'-8" 9-1 4'-8" 5'-3 3/8" 4'-11" 3'-8" 9-2 9-3 9-1 9-2 9-3 1 1 1A 9-4 9-5 9-5 D6-1 D6-1 D6-1 D8-1 D9-1 D9-1 D6-1 D9-2 D9-3 T8 6" TILE BASE W/ SCHLUTER STRIP T6 T7 T9 T1 T2 T3 5'-0" T4 WALL TILE BASE W/ SCHLUTER STRIP T1 T2 T3 T4 5'-0" WALL TILE BASE W/ SCHLUTER STRIP A. EXISTING CONSTRUCTION SHOWN DASHED IS TO BE DEMOLISHED – RECESSED DOWNLIGHT w/ EMERGENCY BALLAST/DRIVER - CEILING MTD. a DUPLEX RECEPTACLE - MOUNTED 6" ABOVE COUNTER MAGNETIC STARTER SAFETY SWITCH - FUSIBLE SAFETY SWITCH - NON-FUSIBLE EQUIPMENT - MOTOR BRANCH CIRCUIT PANELBOARD - FLUSH MOUNTED BRANCH CIRCUIT PANELBOARD - SURFACE MOUNTED POWER RECESSED DOWNLIGHT - CEILING MOUNTED LIGHTING AUTOMATIC TRANSFER SWITCH METER CIRCUIT BREAKER GROUND FIRE ALARM ONE-LINE DIAGRAM GENERATOR DELTA-WYE TRANSFORMER SWITCH SERVICE DROP SHUNT TRIP PUSH BUTTON - MOUNTED 46" AFF CONDUIT - CAPPED CABLE TRAY SEALING FITTING EXPANSION FITTING CONDUIT FITTING (CONDULET) JUNCTION BOX CONDUIT - FLEXIBLE CONDUIT - CONTINUED CONDUIT - CONCEALED BELOW SLAB OR GRADE CONDUIT - UP AND DOWN (CHANGE IN ELEVATION) CONDUIT - TURNING UP CONDUIT - EXPOSED CONDUIT - CONCEALED IN SUSPENDED CEILING OR WALL CONDUIT - TURNING DOWN REVISION CALL-OUT ROOM NUMBER FEEDER CALL-OUT KEYNOTE MECHANICAL EQUIPMENT CALL-OUT: REFER TO THE EQUIPMENT DATA SCHEDULE FOR DETAILS GENERAL JUNCTION BOX - EMERGENCY POWER FOOD SERVICE EQUIPMENT DESIGNATION WIRING AND CONDUITS NEW EQUIPMENT (TYPICAL) EXISTING EQUIPMENT (TYPICAL) DEMOLITION EQUIPMENT (TYPICAL) WALL MOUNT BRACKET (TYPICAL) CARBON MONOXIDE DETECTOR LUMINAIRE - SURFACE MOUNTED OPEN INDUSTRIAL LUMINAIRE RECESSED LUMINAIRE CONNECTED TO THE EMERGENCY POWER SYSTEM OR BALLAST/DRIVER OPEN INDUSTRIAL LUMINAIRE DATE: DRAWN: REVIEWED: SHEET TITLE: SHEET NUMBER: PROJECT NO.: PROJECT: ISSUE: # DATE: DESCRIPTION: NOT FOR CONSTRUCTION DESIGNED: 4/8/2020 10:32:47 AM E0.2 GENERAL INFORMATION JPG APC 0200100.04 Downtown Transit Center - Restroom Upgrades City of Fort Collins 250 N. MASON ST. FORT COLLINS, CO 04.08.2020 INM 90% CD 6. MAXIMUM SIX FOOT FLEXIBLE FIXTURE WHIP SHALL BE USED FOR FINAL CONNECTIONS TO LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS. MAXIMUM FOUR LIGHT FIXTURE WHIPS SHALL BE CONNECTED FROM ONE JUNCTION BOX. FEED THRU BETWEEN LIGHT FIXTURES SHALL NOT BE ALLOWED. 5. NO SHARING OF NEUTRALS ALLOWED. CIRCUIT SHALL HAVE DEDICATED NEUTRAL CONDUCTORS. ONE CIRCUIT, ONE NEUTRAL. 4. DERATING OF CONDUCTOR AMPACITY SHALL BE APPLIED PER NEC. 3. EACH RACEWAY SHALL CONTAIN AN INSULATED EQUIPMENT GROUNDING CONDUCTOR PER NEC. 2. MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG. #10 AWG SHALL BE USED FOR HOME RUNS OF 20 AMP BRANCH CIRCUITS OVER 100 FEET IN LENGTH. 1. MINIMUM CONDUIT SIZE SHALL BE 3/4". T. WHERE CONDUIT AND WIRING RUNS ARE NOT SHOWN ON FLOOR PLANS, THE CONTRACTOR SHALL DETERMINE AND PROVIDE THE REQUIRED CONDUIT AND WIRING FOR SPECIFIED CIRCUITING IN ACCORDANCE WITH NEC AND THE FOLLOWING MINIMUM REQUIREMENTS: S. IF POSSIBLE, ALL NEWLY INSTALLED RECEPTACLES SHALL BE INSTALLED IN SEPARATE OR ADJACENT STUD SPACES, TO AVOID SOUND TRANSMISSION AND WALL INTEGRITY ISSUES. ALL NEWLY INSTALLED RECEPTACLES LOCATED IN COMMON STUD SPACES OF FIRE-RESISTANT WALLS SHALL BE EQUIPPED WITH FIRE-RESISTANT PUTTY PADS AT THE BACK OF EACH BOX IN ACCORDANCE WITH NEC. R. CONTRACTOR SHALL NOT SCALE DRAWING FOR QUANTITIES. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL MEASUREMENTS. Q. UNLESS INDICATED IN SOME MANNER THAT ELECTRICAL EQUIPMENT IS EXISTING, ALL EQUIPMENT SHALL BE NEW. P. PRIOR TO SUBMITTING BID PROPOSAL, BIDDER SHALL EXAMINE ALL GENERAL CONSTRUCTION DRAWINGS AND VISIT CONSTRUCTION SITE TO BE FAMILIAR WITH EXISTING CONDITIONS UNDER WHICH HE WILL HAVE TO OPERATE AND WHICH WILL IN ANY WAY AFFECT THE WORK UNDER THIS CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN THIS CONNECTION ON BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART. O. PROVIDE AND INSTALL IN EACH PANEL, TYPEWRITTEN NEAT TWO-COLUMN CIRCUIT INDEX CARD SET UNDER PLASTIC COVERS ON INSIDE OF DOORS. EACH ODD-NUMBERED CIRCUIT SHALL BE IN SEQUENCE ON ONE COLUMN AND THE EVEN-NUMBERED CIRCUITS ON THE OTHER COLUMN (E.G. 1,3,5...,2,4,6...). EACH CIRCUIT SHALL BE IDENTIFIED AS TO THE USE AND ROOM NAME(S) OR AREA(S). THE CONTRACTOR SHALL CONFIRM ROOM NAMES AND/OR ROOM NUMBERS WITH THE ARCHITECT PRIOR TO PROJECT COMPLETION. OS OS WATER ROOM 3 TOILET 4 TOILET 5 WAITING 6 B A A A A B 1 P3-15 P3-15 P3-15 P3-15 P3-15 P3-15 3 3 WATER ROOM 3 TOILET 4 TOILET 5 WAITING 6 GFI GFI 1 P2-21 P2-21 EF 10 ON ROOF P1-24 4 IG IG IG 1 2 P2-9 P2-21 P2-21 P2-21 P2-21 P2-9 P2-9 P3-15 P3-15 P3-15 P3-15 P3-15 N G M P1 P3 P2 TVSS 208Y/120V, 3PH, 4-WIRE PADMOUNTED UTILITY TRANSFORMER BY CITY OF FORT COLLINS X 29,500A 2 SETS(4#350, 3"C PVC) X BD BOILER BLOW DOWN CD CONDENSATE DRAIN CWS CONDENSER WATER SUPPLY HCWS DUAL TEMPERATURE SUPPLY HPS HIGH PRESSURE STEAM HRS HEAT RECOVERY SUPPLY HTWS HIGH TEMP WATER SUPPLY HWS HOT WATER SUPPLY LPS LOW PRESSURE STEAM LS LOOP SUPPLY MPS MEDIUM PRESSURE STEAM PD PUMP DISCHARGE RHG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION CHR CHILLED WATER RETURN CWR CONDENSER WATER RETURN HCWR DUAL TEMPERATURE RETURN HPR HIGH PRESSURE STEAM CONDENSATE RETURN HRR HEAT RECOVERY RETURN HTWR HIGH TEMP WATER RETURN HWR HOT WATER RETURN LPR LOW PRESSURE STEAM CONDENSATE RETURN LR LOOP RETURN MPR MEDIUM PRESSURE STEAM CONDENSATE RETURN AC ABOVE CEILING/AIR CONDITIONER OA OUTDOOR AIR ACC AIR COOLED CONDENSER AF AIR FILTER AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT AMS AIR MEASURING STATION AS AIR SEPARATOR AV AUTOMATIC AIR VENT B BOILER BAS BUILDING AUTOMATION SYSTEM BDD BACKDRAFT DAMPER BFC BELOW FINISHED CEILING BFP BACKFLOW PREVENTION DEVICE BJ BETWEEN JOISTS BOD BOTTOM OF DUCT BOP BOTTOM OF PIPE BTUH BRITISH THERMAL UNITS PER HOUR CA COMPRESSED AIR CBS COUNTER BALANCED SHUTTER CC COOLING COIL CF CEILING / CIRCULATING FAN CFM CUBIC FEET PER MINUTE CH CHILLER CHP CHILLED WATER PUMP CHR CHILLED WATER RETURN CHS CHILLED WATER SUPPLY CNV CONVECTOR COND CONDENSATE CP CONDENSATE PUMP CRAC COMPUTER ROOM AIR CONDITIONER CTTOWER COOLING CU CONDENSING UNIT CUH CABINET UNIT HEATER CV CONTROL VALVE EXHAUST FAN SCHEDULE MARK MANUFACTURER MODEL TYPE DRIVE SERVICE CFM TSP (IN. W.C.) SONES DAMPER ROOF OPENING ELECTRICAL DATA REMARKS L (IN.) W (IN.) HP/ WATTS V/PH WT. (LBS.) EF-10 COOK ACE-D 90C15DH DOWNBLAST DIRECT RESTROOMS 200 0.3 4.5 BD-12 13.5 13.5 1/8 115/1 42 1-3 NOTES: 1. PROVIDE FAN SPEED CONTROLLER. 2. PROVIDE DISCONNECT AT EXHAUST FAN. 3. FAN TO OPERATE CONTINUALLY. AIR DEVICE SCHEDULE MARK MANUFACTURER MODEL SERVICE STYLE MAX. N.C. MAX. AIR P.D. (IN. W.C.) MODULE SIZE FRAME FINISH MATERIAL REMARKS S1 PRICE SDC SUPPLY CONE 25 0.022 12x12 LAY-IN WHITE ALUMINUM 1 E1 PRICE 80 EXHAUST EGGCRATE 25 0.013 12x12 LAY-IN WHITE ALUMINUM NOTES: 1. PROVIDE BALANCE DAMPER. WATER ROOM 3 TOILET 4 TOILET 5 WAITING 6 8x8 E1 100 8x8 E1 100 8x8 EF 10 2 8"ø 6"ø S1 75 6"ø S1 75 6"ø S 50 PLUMBING PIPING MATERIAL SCHEDULE SYSTEM TYPE MATERIAL SELECTION DOM. CW ABOVE GRADE ASTM B88 (ASTM B88M), TYPE L COPPER OR PEX PIPING (ASTM F876 OR ASTM F877; 160 PSIG AT 73 DEGREES F) FOR ONE INCH PIPING AND SMALLER. DOM. HW ABOVE GRADE ASTM B88 (ASTM B88M), TYPE L COPPER OR PEX PIPING (ASTM F876 OR ASTM F877; 160 PSIG AT 73 DEGREES F) FOR ONE INCH PIPING AND SMALLER. DOM. HWC ABOVE GRADE ASTM B88 (ASTM B88M), TYPE L COPPER OR PEX PIPING (ASTM F876 OR ASTM F877; 160 PSIG AT 73 DEGREES F) FOR ONE INCH PIPING AND SMALLER. SANITARY BELOW GRADE PIPING , WITHIN 5 FEET OF BUILDING CAST IRON, CISPI 301 HUBLESS OR HUB AND SPIGOT PIPING; OR ASTM D2665 SCHEDULE 40 PVC SANITARY ABOVE GRADE PIPING TO FIXTURES CAST IRON, CISPI 301 HUBLESS OR HUB AND SPIGOT PIPING; OR ASTM D2665 SCHEDULE 40 PVC SANITARY VENT PIPING CAST IRON, CISPI 301 HUBLESS OR HUB AND SPIGOT PIPING; OR ASTM D2665 SCHEDULE 40 PVC NOTES: PLASTIC PIPING (PVC, CPVC, PEX, ETC.) IS NOT ALLOWED IN RETURN AIR PLENUMS UNLESS THE PIPING IS ASTM E84 (25/50) RATED AND APPROVED BY ENGINEER FOR USE IN EACH INSTANCE. SUBMIT ALL PIPING TO BE USED TO ENGINEER FOR REVIEW AND APPROVAL PRIOR TO PURCHASE. PROVIDE ALL DOMESTIC SOLDER COPPER SYSTEMS WITH ASME B16.18 OR ASME B16.22 PIPE FITTINGS, SOLDER AND FLUX (IF USED) THAT COMPLY WITH NSF 61 AND NSF 372 FOR MAXIMUM LEAD CONTENT FOR COPPER PIPING INSTALLATIONS. PROVIDE ALL MECHANICAL PRESSED SEALED DOMESTIC COPPER PIPING WITH DOUBLE PRESSED TYPE, NSF 61/NSF 372 APPROVED FITTINGS UTILIZING EDPM, NON-TOXIC RUBBER SEALING ELEMENTS WITH FOOD GRADE RATED LUBRICANTS. FOR DOMESTIC PEX PIPING INSTALLATIONS, PROVIDE WITH BRASS AND COPPER FITTINGS OR BRASS AND ENGINEERED POLYMER (EP) FITTINGS THAT COMPLY WITH ASTM F1960 AND ASTM F1960, OR COLD EXPANSION FITTINGS THAT CONFORM WITH ASTM F1960. PROVIDE ALL HUBLESS CAST IRON PIPING WITH CAST IRON FITTINGS AND EACH JOINT WITH CISPI 310, HEAVY DUTY, STAINLESS STEEL CLAMP AND SHIELD ASSEMBLY WITH NEOPRENE GASKETS. PROVIDE ALL HUB AND SPIGOT CAST IRON PIPING WITH ASTM C564, COMPRESSION TYPE, NEOPRENE GASKETS. PROVIDE ASTM D2564 SOLVENT FOR ANY PVC DRAIN PIPING. FOR ALL PIPING, PROVIDE BRACING IN ACCORDANCE WITH MSS SP 58 ATTACHED TO STRUCTURE OR TRAPEZE HANGERS. GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS. PROVIDE DIELECTRIC INSULATORS FOR ANY DISSIMILAR METAL CONTACT BETWEEN PIPING, AND PIPING-AND-HANGERS IN ALL INSTANCES. PROVIDE CLEARANCE FROM HANGERS, FROM STRUCTURE, AND OTHER EQUIPMENT FOR INSTALLATION OF THE INSULATION AND TO PROVIDE ACCESS TO VALVES, FITTINGS AND OTHER APPURTENANCES. PROVIDE PEX PIPING WITH MANUFACTURER APPROVED, PREFABRICATED HANGERS AND SUPPORTS TO ALLOW FOR PIPING SUPPORTS AND CONFIGUREATIONS SAME/SIMILAR TO COPPER PIPING SUPPORT REQUIREMENTS OF A SIMILAR SIZE. FOR ALL BELOW GRADE METALLIC PIPING, LAP AND DOUBLE WRAP BELOW GRADE PIPING AND PIPING THROUGH GRADE PENETRATIONS CONTINUOUSLY TO APPROXIMATELY THREE INCHES ABOVE GRADE WITH PROTECTIVE TAPE AND/OR PLASTIC WRAPPING TO PREVENT DAMAGE AND CORROSION. COORDINATE EXACT REQUIREMENTS WITH LOCAL AHJ PRIOR TO INSTALLATION. IN ALL CASES REFER TO PLUMBING SPECIFICATIONS. COMMON REQUIREMENTS GENERAL NOTES A. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISCONNECTION AND WATER ROOM TOILET 3 4 TOILET 5 WAITING 6 3/4"HW 1/2"HWC 1 1/2"CW 1 1/2"CW 1/2"HWC 3/4"HW 3/4"CW 1"CW 1"CW 3/4"HW 3/4"CW 3/4"HW 1/2"HWC 1 4 7 6 6 7 1 2 3 9 3/4"HW 1/2"HWC 1 1/2"CW 4"FCO 4"W 4"FCOW 4" 4"W 1 1/2"CW 1/2"HWC 3/4"HW 3/4"CW 2"V (E) VENT PIPING SHOWN HERE IS BELOW SLAB BEFORE RISING IN WALL TO OVERHEAD. TO 3"VTR FROM (E) WATER ENTRY 3 5 4 4 SAW CUT IN THIS WORK AREA AS REQUIRED FOR NEW FIXTURE INSTALLATIONS. WATER ROOM 3 TOILET 4 TOILET 5 WAITING 6 4"FCO 4"W 4"FCOW 4" 4"W 4"W 2"V 2"V 2"V 1 1/2"V 2"V 1 1/2"W 4"W 1 1/2"W 5 4 3 8 8 2"V HOT WATER SUPPLY TYPICAL QUATER TURN STOP COLD WATER SUPPLY TW TYPICAL LAVATORY (SELF-RIMMING OR WALL HUNG) TMV (SEE SCHEDULE) SENSOR FAUCET DATE: DRAWN: REVIEWED: SHEET TITLE: SHEET NUMBER: PROJECT NO.: PROJECT: ISSUE: # DATE: DESCRIPTION: NOT FOR CONSTRUCTION DESIGNED: 4/7/2020 10:16:43 AM P1.1 DEMO AND NEW FLOORPLAN, NOTES, AND DETAILS BAJ CRF 0200100.04 Downtown Transit Center - Restroom Upgrades City of Fort Collins 250 N. Mason St, Fort Collins, CO 04.08.2020 JMB 90% CD I. ENSURE BUILDING SUPPLY PRESSURE IS SET NO HIGHER THAN 80 PSI MAX. H. ALL NEW WASTE PIPING SHOWN IS BELOW THE FLOOR OF THE INDICATED LEVEL. G. GROUP ALL DOMESTIC PIPING. PIPE LABELS ARE TO BE READ FROM LEFT TO RIGHT OR TOP TO BOTTOM. F. ALL WATER PIPING SHALL BE INSULATED PER THE IECC AND PVC-JACKETED. E. ALL VALVES SHOWN ARE TO BE LINE SIZED AND NORMALLY OPEN UNLESS OTHERWISE INDICATED ON THE DRAWINGS. D. ALL NEW DOMESTIC AND VENT PIPING SHALL BE MOUNTED AS HIGH AS POSSIBLE IN THE OVERHEAD SPACE. REFERENCE STRUCTURAL DRAWINGS. C. INSTALL ALL FIXTURES, APPURTENANCES, VALVES, AND EQUIPMENT AS PER THE MANUFACTURERS RECOMMENDATIONS. B. SUBMIT ALL PIPING, FITTINGS, HANGERS, FIXTURES AND ASSOCIATED APPURTENANCES TO BE USED FOR THIS PROJECT TO ENGINEER FOR REVIEW AND APPROVAL PRIOR TO PURCHASE. A. REFER TO P0.1 FOR ADDITIONAL GENERAL NOTES. GENERAL NOTES 0 2 4 8 NORTH TRUE SCALE: 1/4" = 1'-0" 2 DOMESTIC PLUMBING PLAN KEYNOTES # 1 ROUTE HOT WATER PIPING DOWN IN WALL HERE TO BEHIND THE STOP VALVES THAT SERVE THE LAVATORIES. CONNECT HOT WATER CIRCULATION PIPING JUST DOWNSTREAM OF THIS POINT AND BACK UP IN WALL TO OVERHEAD AS SHOWN. 2 PROVIDE BALANCE VALVE FOR APPROXIMATELY 0.5 GPM AND 1 PSI OF PRESSURE DROP. EXISTING BUILDING HOT WATER CIRCULATION SYSTEM FOR A FULL FUNCTIONING HOT WATER SYSTEM FOR THE ENTIRE BUILDING. 3 TO/FROM CONFERENCE AND BREAKROOM. 4 TO/FROM RESTROOMS, WORK ROOM, AND JANITORS CLOSET. 5 TO 4" BUILDING DRAIN. I.E. AT BLDG EDGE ~4.0 FT BFF. 6 ADA COMPLIANT, ELONGATED, FLOOR MOUNTED, PRESSURE ASSISTED FLUSH TANK WATER CLOSET. MUST BE WATER SENSE CERTIFIED AND FLUSH ON 1.1 GPF. KOHLER: HIGHLINE CLASSIC COMFORT HEIGHT. (MODEL: K-3519-T) PROVIDE WITH OPEN FRONT SEAT, LESS COVER, WITH STAINLESS STEEL, SELF SUSTAINING CHECK HINGE.PROVIDE WITH SLOAN/FLUSHMATE INTELLI-FLUSH ON WALL SENSOR TYPE ADAPTER IN WHITE. (MODEL: K-100100) COORDINATE WITH SUPPLIER TO ENSURE ACCURATE ADAPTER IS SUPPLIED. PROVIDE PER MANUFACTURERS RECOMMENDATIONS AND COORDINATE MOUNTING HEIGHT TO MATCH SAME/SIMILAR TO EXISTING RESTROOM CONFIGURATIONS. 7 ADA COMPLIANT, WALL MOUNTED, WHITE VITREOUS CHINA LAVATORY WITH 20 INCH X 18 INCH BASIN. PROVIDE BASIN WITH 3 HOLE DRILLINGS ON 4 INCH CENTERS, 4 INCH BACK SPLASH, OVERFLOW, AND CONCEALED ARM SUPPORTS FOR IN WALL LAVATORY CARRIER. AMERICAN STANDARD: LUCERNE. PROVIDE WITH A SENSOR ACTIVATED, BATTERY POWERED, CHROME PLATED CONVENTIONAL SPOUT FAUCET WITH 0.5 GPM VANDAL RESISTANT AERATOR. DELTA: 591LF-LGHGMHDF PROVIDE TRIM WITH: MINIMUM 17-GAUGE 1-1/4 INCH OFFSET GRID STRAINER AND P-TRAP WITH INTEGRAL CLEANOUT; QUARTER TURN, CHROME PLATED SOLID BRASS ANGLE STOPS AND WITH FLEXIBLE CONNECTORS AND CHROME PLATED WALL ESCUTCHEONS; WITH ADA TRAP, STOP, AND SUPPLY PROTECTORS. PROVIDE WITH THERMOSTATIC MIXING VALVES OF LEAD FREE CONSTRUCTION FOR SINGLE FIXTURE APPLICATIONS ALLOWING DOWN TO 0.25 GPM AND SET OUTLET TO 105 DEG F MAX. WATTS: LFUSG-B. 8 2 INCH FLOOR DRAIN. PROVIDE WITH NICKEL-BRONZE FINISH AND HEEL-PROOF, ROUND GRATING. JAY R. SMITH: 2005. PROVIDE WITH INSERTED, ELASTOMERIC TRAP SEAL THAT IS ASSE 10702 COMPLIANT. 9 GROUP NEW RESTROOM(S) VALVES TOGETHER. FIELD COORDINATE EXACT PLACEMENTS FOR ACCESSIBLE LOCATION(S) FOR EASE OF MAINTENANCE. PROVIDE LABEL(S) WITH VALVING TO INDICATE AREA SERVED. SCALE: 1/4" = 1'-0" 1 PLUMBING DEMOLITION PLAN KEY PLAN SCALE: 1/4" = 1'-0" 3 DRAIN WASTE AND VENT PLAN D. EXISTING CONDITIONS ARE DRAWN TO MOST CURRENT INFORMATION AVAILABLE TO ENGINEER AND TO ILLUSTRATE DIAGRAMMATIC INTENT. FIELD VERIFY EXISTING PIPING CONDITIONS PRIOR TO START OF WORK. COORDINATE IN WRITING WITH ENGINEER OF ANY DEVIATIONS OBSERVED. C. ALL EXISTING DOMESTIC PIPING SHOWN IS IN THE OVERHEAD SPACE OF THE INDICATED LEVEL. B. ALL EXISTING WASTE PIPING SHOWN IS BELOW THE FLOOR OF THE INDICATED LEVEL. A. REFER TO P0.1 FOR ADDITIONAL GENERAL DEMOLITION NOTES. GENERAL DEMOLITION NOTES D. ALL FIRE PROTECTION RELATED EQUIPMENT AND PIPING WHICH IS REMOVED FROM THE BUILDING IS TO BE TAKEN OFFSITE AND DISPOSED OF LEGALLY. C. COORDINATE DEMOLITION OF FIRE PROTECTION PIPING WITH OTHER PIPING WHICH IS NOT TO BE REMOVED. PROTECT OTHER PIPING WHICH IS NOT TO BE REMOVED FROM DAMAGE, DIRT, AND DEBRIS. B. COORDINATE WITH OWNER FOR ANY SHUTDOWNS OR PLANNED INTERRUPTIONS OF THE FIRE PROTECTION SERVICE. THE CONTRACTOR SHALL GIVE THE OWNER THREE (3) DAYS NOTICE PRIOR TO THE PLANNED SHUTDOWN OR INTERRUPTION. A. THE CONTRACTOR IS TO FIELD VERIFY THE EXACT LOCATIONS OF EXISTING FIRE PROTECTION LINES AND EQUIPMENT INCLUDING RISERS AND VALVES PRIOR TO THE START OF WORK. FIRE PROTECTION GENERAL DEMOLITION NOTES F. CENTER ALL SPRINKLER HEADS IN WORK AREA IN TWO DIRECTIONS WHEN LOCATED IN CEILING SPACES WITH CEILING TILES AND SYMMETRICALLY WITH OTHER CEILING DEVICES IN GYP CEILINGS. ARCHITECT SHALL HAVE FINAL APPROVAL OF SYMMETRICAL LAYOUT PRIOR TO INSTALLATION. E. PROVIDE SERVICED AREAS WITH NEW SPRINKLER HEADS AND PIPING TO MATCH EXISTING AS REQUIRED. PROVIDE A NEW SPARE HEAD FOR MAINTENANCE PURPOSES. D. ADJUST SPRINKLER HEAD LOCATIONS AND TYPES AS REQUIRED FOR THE NEW SPACE LAYOUTS. REFER TO ARCHITECTURAL DRAWINGS FOR SPACE CATEGORY CLASSIFICATIONS AND REFLECTED CEILING PLANS FOR COORDINATION. C. PROVIDE AS-BUILT SHOP DRAWING UPON COMPLETION OF INSTALLATION. B. PRESSURE TEST SYSTEM UPON COMPLETION OF INSTALLATION IN ACCORDANCE WITH 2013 NFPA 13. REPAIR LEAKS IN PIPING UNDER THIS CONTRACT. A. PROVIDE RENOVATED FIRE PROTECTION SYSTEM TO PROVIDE FIRE PROTECTION COVERAGE OF RENOVATION AREAS IN ACCORDANCE 2013 NFPA 13, LOCAL CODES AND ALL AHJ DESIGN GUIDELINES AND INSTALLATION REQUIREMENTS. FIRE PROTECTION GENERAL NOTES SECTION- BASIC PLUMBING GENERAL REQUIREMENTS PART 1- GENERAL SUMMARY SECTION SPECIFIES THE BASIC REQUIREMENTS FOR PLUMBING INSTALLATIONS AND INCLUDES REQUIREMENTS COMMON TO MORE THAN ONE SECTION OF THE SPECIFICATIONS. GENERAL REFERENCES ALL OF THE DRAWINGS AND SPECIFICATIONS ARE CONSIDERED A PART OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SEARCHING ALL CONTRACT DOCUMENTS TO DETERMINE THE SCOPE OF WORK REQUIRED IN FINAL CONNECTIONS TO EQUIPMENT PROVIDED BY OTHER CONTRACTS OR CONTRACTORS. IT IS THE INTENT OF THE DRAWINGS TO PROVIDE AS MUCH INFORMATION AS POSSIBLE ON EQUIPMENT PROVIDED BY OTHERS. HOWEVER, THE EXTENT OF FINAL CONNECTIONS AND TYPE OF FINAL CONNECTIONS SHALL BE DETERMINED BY THE ACTUAL EQUIPMENT SUPPLIED BY OTHERS. THIS CONTRACTOR SHALL INCLUDE IN HIS BASE BID, REASONABLE COST FOR THE INSTALLATION OF EQUIPMENT PROVIDED BY OTHERS. HE SHALL NOT BE AWARDED EXTRA COSTS AFTER THE CONTRACT IS AWARDED UNLESS THE EQUIPMENT SO INSTALLED IS NOT SHOWN ON ANY OF THE CONTRACT DOCUMENTS. WORK INCLUDED UNDER THIS DIVISION SHALL CONSIST OF FURNISHING ALL MATERIALS, SUPPLIES, EQUIPMENT, TOOLS, INSURANCE, TRANSPORTATION AND FACILITIES, AND PERFORMING ALL LABOR AND SERVICES NECESSARY FOR COMPLETE INSTALLATION OF THE NEW PLUMBING SYSTEM(S). DRAWINGS DRAWINGS ARE DIAGRAMMATIC, INDICATING ONLY APPROXIMATE LOCATIONS OF SERVICES, FIXTURES, APPARATUS, AND PIPING UNLESS NOTED OTHERWISE, AND ARE NOT TO BE SCALED. ACTUAL INSTALLATION MUST CONFORM TO ACTUAL BUILDING CONDITIONS AND VERIFIED IN THE FIELD. THE ARCHITECT/ ENGINEER RESERVES THE RIGHT TO EFFECT REASONABLE CHANGES IN THE LOCATION OF EQUIPMENT UP TO THE TIME OF ROUGH-IN WITHOUT ADDITIONAL COST TO THE OWNER. ANY AND ALL CHANGES SHALL BE APPROVED BY THE ARCHITECT/ ENGINEER. MAINTAIN MANUFACTURERS RECOMMENDED CLEARANCES AROUND ALL EQUIPMENT. THE DECISION OF THE ARCHITECT/ ENGINEER AS TO THE TRUE INTENT AND MEANING OF THE PLANS AND SPECIFICATIONS SHALL BE FINAL AND BINDING UPON BOTH PARTIES TO THE CONTRACT. ITEMS OMITTED FROM THE DRAWINGS BUT SPECIFIED, OR ITEMS CALLED FOR ON THE DRAWINGS BUT OMITTED FROM THE SPECIFICATIONS, SHALL BE CONSIDERED AS APPEARING IN BOTH. WHERE A CONFLICT OCCURS BETWEEN SPECIFICATIONS AND DRAWINGS, THE MOST EXPENSIVE ITEM WILL TAKE PRECEDENCE. THE CONFLICT WILL THEN BE RESOLVED DURING CONSTRUCTION AND A CREDIT ISSUED FOR A LESS COSTLY SOLUTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL PLUMBING PIPING, AND TO CONFORM TO ACTUAL BUILDING STRUCTURAL CONDITIONS. ITEMS OMITTED FROM DRAWINGS AND/ OR SPECIFICATIONS BUT REQUIRED FOR PROPER OPERATION OF EQUIPMENT OR FIXTURES BY MANUFACTURER SHALL BE CONSIDERED AS PART OF THE CONTRACT DOCUMENTS. ITEMS AS STATED ABOVE WHICH ARE NECESSARY TO COMPLY WITH THE INTENT OF THE CONTRACT DOCUMENTS SHALL BE CONSIDERED AS PART OF THE CONTRACT REQUIREMENTS. REGULATORY REQUIREMENTS PLUMBING TO CONFORM TO THE STATE OF COLORADO STATE PLUMBING CODE, INTERNATIONAL PLUMBING CODE, AND LOCAL, COUNTY, AND CITY CODES. SECURE AND PAY FOR ALL PERMITS AND CERTIFICATIONS OF INSPECTIONS INCIDENTAL TO THIS WORK REQUIRED BY FOREGOING AUTHORITIES. BE RESPONSIBLE FOR PAYMENTS TO ALL PUBLIC UTILITIES FOR WORK PERFORMED BY THEM IN CONNECTION WITH THE PROVISION OF SERVICE CONNECTION REQUIRED. DELIVER ALL CERTIFICATES TO ARCHITECT/ ENGINEER IN DUPLICATE. PART 2- PRODUCTS (REFER TO PLUMBING SCHEDULES) PART 3- EXECUTION OPERATIONS MANUAL THIS CONTRACTOR SHALL FURNISH COMPETENT PERSONNEL TO INSTRUCT THE OWNER'S OPERATING PERSONNEL IN THE PROPER OPERATION OF EACH PIECE OF EQUIPMENT AND FIXTURES. PRIOR TO FINAL PAYMENT DEMONSTRATE TO THE OWNER'S SATISFACTION THE PROPER OPERATION OF EACH AND ALL SYSTEMS, INSTRUCTING IN OPERATION AND MAINTENANCE OF PLUMBING FIXTURES AND EQUIPMENT. GENERAL PIPING AND VALVES ALL PIPING SHALL BE INSTALLED PARALLEL WITH, OR AT RIGHT ANGLES TO, THE BUILDING WALLS. ALL VERTICAL RISERS SHALL BE INSTALLED PLUMB AND STRAIGHT. ALL PIPING SHALL BE INSTALLED WITH A PITCH IN THE DIRECTION OF FLOW OF NOT LESS THAN ONE INCH IN FORTY FEET, EXCEPT AS OTHERWISE SHOWN. IT MUST BE POSSIBLE TO DRAIN EVERY PORTION OF THE PIPING SYSTEM. DRAINS SHALL HAVE HOSE THREAD ENDS. ANY PIPE RESTING ON OR COMING IN CONTACT WITH BUILDING STRUCTURE OR SUPPLEMENTAL SUPPORTS SHALL BE INSULATED AT THAT POINT TO PREVENT TELEGRAPHING OF SOUND OR VIBRATION. ALL PLUMBING PIPING SHALL BE RIGIDLY SUPPORTED AND SHALL NOT BE LOOSE OR SHAKY. COPPER WATER PIPING JOINTS SHALL BE MADE WITH THE SCHEDULED FITTINGS. SURFACE TO BE SOLDERED SHALL BE CLEANED BRIGHT, PROPERLY FLUXED AND MADE WITH SILVER SOLDER OF NOT LESS THAN 95-5. JOINTS BETWEEN COPPER PIPE TO SCREWED PIPE JOINTS SHALL BE MADE BY USE OF A BRASS FITTING. CLEAN- UP AT ALL TIMES KEEP PREMISES AND BUILDING IN NEAT ORDERLY CONDITION, FOLLOW EXPLICITLY ANY INSTRUCTIONS OF CONSTRUCTION MANAGER AND ARCHITECT/ ENGINEER IN REGARD TO STORING OF MATERIALS, PROTECTIVE MEASURES, CLEANING- UP OF DEBRIS, ETC. UPON COMPLETION OF THE WORK THE CONTRACTOR SHALL THOROUGHLY CLEAN ALL FIXTURES, FAUCET AERATORS, FLUSH VALVE DIAPHRAGMS, EQUIPMENT, PACK ALL VALVES REMOVING ALL DIRT, GREASE AND OIL. FIRE AND SOUND STOPPING PIPE SLEEVES SHALL BE SIZED TO ALLOW FOR PROPER ANNULAR SPACE BETWEEN SLEEVE AND PIPE OR INSULATION. SEAL THE ANNULAR SPACE WITH A FIRE RETARDANT CAULK OR PUTTY ON ALL WALLS USING UL APPROVED METHOD AS RECOMMENDED BY THE SEALANT MANUFACTURER. THE SIZE OF THE ANNULAR SPACE WILL VARY DEPENDENT ON THE SEALANT APPLICATION TECHNIQUE WITH THE SEALANT MANUFACTURER. FIRE AND SOUND STOPPING SEALER SHALL BE 3M FIRE BARRIER CAULK CP25 OR PUTTY 303, THOMAS & BETTS FLAME-SAFE FIRE STOP COMPOUND OR NELSON FLAMESEAL PUTTY. SECTION- ESCUTCHEONS FOR PLUMBING PIPING PART 1- GENERAL SUMMARY ESCUTCHEONS FOR PIPING AT CEILING, FLOOR AND WALL PENETRATIONS. PART 2 - PRODUCTS ESCUTCHEONS ONE-PIECE, CAST BRASS TYPE, WITH POLISHED, CHROME-PLATED AND ROUGH-BRASS FINISH AND SETSCREW FASTENER. ONE-PIECE, DEEP-PATTERN TYPE: DEEP-DRAWN, BOX-SHAPED BRASS WITH CHROME-PLATED FINISH AND SPRING-CLIP FASTENERS. ONE-PIECE, STAMPED-STEEL TYPE: WITH CHROME-PLATED FINISH AND SPRING-CLIP FASTENERS. PART 3 - EXECUTION INSTALLATION INSTALL ESCUTCHEONS FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FINISHED FLOORS. INSTALL ESCUTCHEONS WITH ID TO CLOSELY FIT AROUND PIPE, TUBE, AND INSULATION OF PIPING AND WITH OD THAT COMPLETELY COVERS OPENING. FIELD QUALITY CONTROL REPLACE BROKEN AND DAMAGED ESCUTCHEONS AND FLOOR PLATES USING NEW MATERIALS. PART 3 - EXECUTION (NOT APPLICABLE) SECTION- GENERAL-DUTY VALVES FOR PLUMBING PIPING PART 1- GENERAL SUMMARY SECTION INCLUDES GENERAL DUTY VALVES COMMON TO MULTIPLE PLUMBING SYSTEMS. ACTION SUBMITTALS PRODUCT DATA: FOR EACH TYPE OF VALVE INDICATED. QUALITY ASSURANCE ASME COMPLIANCE: ASME B16:10 AND ASME B16:34 FOR FERROUS VALVE DIMENSIONS AND DESIGN CRITERIA. ASME B31.1 FOR POWER PIPING VALVES. ASME B31.9 FOR BUILDING SERVICES PIPING VALVES. NSF COMPLIANCE: NSF 61 FOR VALVE MATERIALS FOR POTABLE-WATER SERVICE. PART 2 - PRODUCTS GENERAL REQUIREMENTS FOR VALVES VALVE PRESSURE AND TEMPURATURE RATINGS: NOT LESS THAN INDICATED AND AS REQUIRED FOR SYSTEM PRESSURES AND TEMPERATURES. BRONZE BALL VALVES TWO-PIECE, FULL-PORT, BRONZE BALL VALVES WITH BRONZE TRIM. DESCRIPTION: STANDARD: MSS SP-110, SWP RATING: 150 PSIG; BODY DESIGN: TWO PIECE; BODY MATERIAL: BRONZE. DESCRIPTION: BRONZE SWING CHECK VALVES CLASS 150, BRONZE SWING CHECK VALVES WITH BRONZE DISC: DESCRIPTION: STANDARD: MSS SP-80, TYPE 3, BODY DESIGN: HORIZONTAL FLOW, BODY MATERIAL: ASTM B 62, BRONZE, ENDS: THREADED, DISC: BRONZE. VALVE INSTALLATION LOCATE VALVES FOR EASY ACCESS AND PROVIDE SEPARATE SUPPORT WHERE NECESSARY. IF VALVES WITH SPECIFIED SWP CLASSES OR CWP RATINGS ARE NOT AVAILABLE, THE SAME TYPES OF VALVES WITH HIGHER SWP CLASSES OR CWP RATINGS MY BE SUBSTITUTED. DOMESTIC, HOT-AND COLD-WATER VALVE SCHEDULE PIPE NPS2 AND SMALLER: BRONZE VALVES: MAY BE PROVIDED WITH SOLDER-JOINT ENDS INSTEAD OF THREADED ENDS. BALL VALVES: TWO PIECE, FULL PORT, BRONZE WITH BRONZE DISC. PERFORMANCE REQUIREMENTS DELEGATED DESIGN: DESIGN TRAPEZE PIPE HANGERS AND EQUIPMENT SUPPORTS, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BY A QUALIFIED PROFESSIONAL ENGINEER, USING PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED. ACTION SUBMITTALS PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. PART 2 - PRODUCTS METAL PIPE HANGERS AND SUPPORTS CARBON-STEEL PIPE HANGERS AND SUPPORTS: DESCRIPTION: MSS SP-58, TYPES 1 THROUGH 58, FACTORY-FABRICATED COMPONENTS. GALVANIZED METALLIC COATINGS: PRE-GALVANIZED OR HOT DIPPED. HANGER RODS: CONTINUOUS- THREAD ROD, AND WASHER MADE OF CARBON STEEL. COPPER PIPE HANGERS: DESCRIPTION: MSS SP-58, TYPES 1 THROUGH 58, COPPER-COATED-STEEL, FACTORY-FABRICATED COMPONENTS. HANGER RODS: CONTINUOUS-THREAD ROD, NUTS, AND WASHER MADE OF COPPER- COATED STEEL. TRAPEZE PIPE HANGERS DESCRIPTION: MSS SP-69, TYPE 59, SHOP-OR FIELD-FABRICATED PIPE-SUPPORT ASSEMBLY MADE FROM STRUCTURAL CARBON-STEEL SHAPES WITH MSS SP-58 CARBON-STEEL HANGER RODS, NUTS, SADDLES, AND U-BOLTS. FASTENER SYSTEMS MECHANICAL-EXPANSION ANCHORS: INSERT-WEDGE TYPE ZINC COATED, STAINLESS-STEEL ANCHORS, FOR USE IN HARDENED PORTLAND CEMENT CONCRETE; WITH PULL-OUT, TENSION, AND SHEAR CAPACITIES APPROPRIATE FOR SUPPORTED LOADS AND BUILDING MATERIALS WHERE USED. PIPE POSITIONING SYSTEMS DESCRIPTION: IAPMO PS 42, POSITIONING SYSTEM OF METAL BRACKETS, CLIPS AND STRAPS FOR POSITIONING PIPING IN PIPE SPACES, FOR PLUMBING FIXTURES IN COMMERCIAL APPLICATIONS. SECTION- IDENTIFCATION FOR PLUMBING PIPING AND EQUIPMENT PART 1- GENERAL SUMMARY SECTION INCLUDES LABELS, STENCILS, AND VALVE TAGS COMMON TO PLUMBING SYSTEMS. ACTION SUBMITTALS PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. PART 2 – PRODUCTS PIPE LABELS GENERAL REQUIREMENTS FOR MANUFACTURED PIPE LABELS: PREPRINTED, COLOR-CODED, WITH LETTERING INDICATED SERVICE, AND SHOWING FLOW DIRECTION. SELF-ADHESIVE PIPE LABELS: PRINTED PLASTIC WITH CONTACT-TYPE, PERMANENT-ADHESIVE BACKING. PIPE LABEL CONTENTS: INCLUDE IDENTIFICATION OF PIPING SERVICE USING SAME DESIGNATIONS OR ABBREVIATIONS AS USED ON DRAWINGS; ALSO INCLUDE PIPE SIZE AND AN ARROW INDICATING FLOW DIRECTION. PART 3 – EXECUTION PIPE LABEL INSTALLATION PIPE LABEL LOCATIONS: LOCATE PIPE LABELS WHERE PIPING IS EXPOSED OR ABOVE ACCESSIBLE CEILINGS IN FINISHED SPACES; MACHINE ROOMS; ACCESSIBLE MAINTENANCE SPACES SUCH AS SHAFTS, TUNNELS, AND PLENUMS. SECTION- PLUMBING PIPING INSULATION PART 1- GENERAL SUMMARY SECTION INCLUDES INSULATION, JACKETS AND INSULATION ACCESSORIES FOR PLUMBING PIPING TO PREVENT HEAT LOSS IN ACCORDANCE WITH THE LATEST ENERGY STANDARDS. ACTION SUBMITTALS PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. QUALITY ASSURANCE SURFACE-BURNING CHARACTERISTICS: FOR INSULATION AND RELATED MATERIALS, AS DETERMINED BY TESTING IDENTICAL PRODUCTS ACCORDING TO ASTM E 84 BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. FACTORY LABEL INSULATION AND JACKET MATERIALS AND ADHESIVE, MASTIC, TAPES, AND CEMENT MATERIAL CONTAINERS, WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING AGENCY. INSULATION INSTALLED INDOORS: FLAME-SPREAD INDEX OF 25 OR LESS, AND SMOKE-DEVELOPED INDEX OF 50 OR LESS. COMPLY WITH THE FOLLOWING APPLICABLE STANDARDS AND OTHER REQUIREMENTS SPECIFIED FOR MISCELLANEOUS COMPONENTS: SUPPLY AND DRAIN PROTECTIVE SHIELDING GUARDS: ICC A117.1. PART 2 – PRODUCTS INSULATION MATERIALS COMPLY WITH REQUIREMENTS IN “PIPING INSULATION SCHEDULE, GENERAL,” “INDOOR PIPING INSULATION SCHEDULE,” ARTICLES FOR WHERE INSULATING MATERIALS SHALL BE APPLIED. PRODUCTS SHALL NOT CONTAIN ASBESTOS, LEAD, MERCURY, OR MERCURY COMPOUND. FLEXIBLE ELASTOMERIC INSULATION: CLOSED-CELL, SPONGE-OR EXPANDED-RUBBER MATERIALS. COMPLY WITH ASTM C534, TYPE I FOR TUBULAR MATERIALS. MINERIAL-FIBER, PREFORMED PIPE INSULATION: TYPE I, 850 DEG F MAXIMUM SERVICE TEMPERATURE MATERIALS: MINERAL OR GLASS FIBERS BONDED WITH A THERMOSETTING RESIN. COMPLY WITH ASTM C547 AND ASTM C795, TYPE I, GRADE A, WITH FACTORY-APPLIED ASJ. FACTORY- APPLIED JACKET. SHALL HAVE A ‘K’ VALUE OF 0.24 AT 75 DEGREES F. AS PER ASTM C177. ADHESIVES FLEXIBLE ELASTOMERIC AND POLYOLEFIN ADHESIVE: COMPLY WITH MIL-A-24179A, TYPE II, CLASS I. MINERAL-FIBER ADHESIVE: COMPLY WITH MIL-A-3316C, CLASS 2, GRADE A. ASJ ADHESIVE, AND FSK JACKET ADHESIVE: COMPLY WITH MIL-A-3316C, CLASS 2, GRADE A FOR BONDING INSULATION JACKET LAP SEAMS AND JOINTS. SEALANTS JOINT SEALANTS: MATERIALS SHALL BE COMPATIBLE WITH INSULATION MATERIALS, JACKETS, AND SUBSTRATES. PERMANENTLY FLEXIBLE, ELASTOMERIC SEALANT. SERVICE TEMPERATURE RANGE: MINUS 100 TO PLUS 300 DEG F. FACTORY-APPLIED JACKETS INSULATION SYSTEM SCHEDULES INDICATE FACTORY-APPLIED JACKETS ON VARIOUS APPLICATIONS. WHEN FACTORY-APPLIED JACKETS ARE INDICATED, COMPLY WITH THE FOLLOWING: ASJ-SSL: ASJ WITH SELF-SEALING, PRESSURE-SENSITIVE, ACRYLIC-BASED ADHESIVE COVERED BY A REMOVABLE PROTECTIVE STRIP; COMPLYING WITH ASTM C 1136, TYPE I. TAPES ASJ TAPE: WHITE VAPOR-RETARDER TAPE MATCHING FACTORY-APPLIED JACKET WITH ACRYLIC ADHESIVE, COMPLYING WITH ASTM C 1136. SECUREMENTS STAPLES: OUTWARD-CLINCHING INSULATION STAPLES, NOMINAL ¾ INCH-WIDE, STAINLESS STEEL OR MONEL. PROTECTIVE SHIELDING GUARDS PROTECTIVE SHIELDING PIPE COVERS. DESCRIPTION: MANUFACTURED PLASTIC WRAPS FOR COVERING PLUMBING FIXTURE HOT-AND COLD-WATER SUPPLIES AND TRAP AND DRAIN PIPING. COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS. PART 3 – EXECUTION GENERAL INSTALLATION REQUIREMENTS INSTALL INSULATION MATERIALS, ACCESSORIES, AND FINISHES WITH SMOOTH, STRAIGHT, AND EVEN SURFACES; FREE OF VOIDS THROUGHOUT THE LENGTH OF PIPING INCLUDING FITTINGS, VALVES, AND SPECIALTIES. INSTALL INSULATION MATERIALS, FORMS, VAPOR BARRIERS OR RETARDERS, JACKETS, AND THICKNESSES REQUIRED FOR EACH ITEM OF PIPE SYSTEM AS SPECIFIED IN INSULATION SYSTEM SCHEDULES. INSTALL ACCESSORIES COMPATIBLE WITH INSULATION MATERIALS AND SUITABLE FOR THE SERVICE. INSTALL ACCESSORIES THAT DO NOT CORRODE, SOFTEN, OR OTHERWISE ATTACK INSULATION OR JACKET IN EITHER WET OR DRY STATE. INSULATION INSTALLATION AT INTERIOR WALL AND PARTITION PENETRATIONS (THAT ARE NOT FIRE RATED): INSTALL INSULATION CONTINUOUSLY THROUGH WALLS AND PARTITIONS. INSULATION INSTALLATION AT FIRE-RATED WALL AND PARTITION PENETRATIONS: INSTALL INSULATION CONTINUOUSLY THROUGH PENETRATIONS OF FIRE-RATED WALLS AND PARTITIONS. GENERAL PIPE INSULATION INSTALLATION INSULATION INSTALLATION OF STRAIGHT PIPES AND TUBES: SECURE EACH LAYER OF PREFORMED PIPE INSULATION TO PIPE WITH WIRE OR BANDS AND TIGHTEN BANDS WITHOUT DEFORMING INSULATION MATERIALS. FOR INSULATION WITH FACTORY-APPLIED JACKETS ON BELOW-AMBIENT SURFACES, DO NOT STAPLE LONGITUDINAL TABS. INSTEAD, SECURE TABS WITH ADDITIONAL ADHESIVE AS RECOMMENDED BY INSULATION MATERIALS. FOR INSULATION WITH FACTORY-APPLIED JACKETS ON BELOW-AMBIENT SURFACES, DO NOT STAPLE LONGITUDINAL TABS. INSTEAD, SECURE TABS WITH ADDITIONAL ADHESIVE AS RECOMMENDED BY INSULATION MATERIAL MANUFACTURER AND SEAL WITH VAPOR- BARRIER MASTIC AND FLASHING SEALANT. INSULATION INSTALLATION ON PIPE FITTINGS AND ELBOWS: INSTALL PREFORMED SECTIONS OF SAME MATERIAL AS STRAIGHT SEGMENTS OF PIPE INSULATION WHEN AVAILABLE. WHEN PREFORMED INSULATION ELBOWS AND FITTINGS ARE NOT AVAILABLE, INSTALL MITERED SECTIONS OF PIPE INSULATION, TO A THICKNESS EQUAL TO ADJOINING PIPE INSULATION. SECURE INSULATION MATERIALS WITH WIRE OR BANDS. DIVISION 22 0000 SPECIFICATIONS SCALE: NOT TO SCALE 4 POINT-OF-USE MIXING VALVE SENSOR OPERATED DIAGRAM REMOVAL OF ALL PLUMBING FIXTURES, PIPING, EQUIPMENT, AND ASSOCIATED APPURTENANCES. NO PERSON OTHER THAN A LICENSED PLUMBER SHALL REMOVE PLUMBING ITEMS FROM THEIR ORIGINAL LOCATION. B. SHUTDOWN OF EXISTING SYSTEMS SHALL BE COORDINATED WITH OWNER TO LIMIT INTERFERENCE WITH OWNER'S OPERATION AND DOWNTIME. CONTRACTOR SHALL SUBMIT TO OWNER FOR REVIEW AND APPROVAL, THE PROPOSED PHASING PLAN FOR SHUTDOWN OF EXISTING SERVICES. C. CONTRACTOR SHALL COMPLY WITH GENERAL CONDITIONS AND PROTECTION PROVISIONS SPECIFIED FOR JOINT OWNER/CONTRACTOR OCCUPANCY WORK AREAS. D. CONTRACTOR SHALL PROTECT EXISTING UTILITIES TO REMAIN FROM DAMAGE DURING DEMOLITION. ANY UTILITIES AND SERVICES DAMAGED SHALL BE REPAIRED AT NO EXPENSE TO OWNER. E. CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO TEMPORARILY MOVING OR TAKING EQUIPMENT OUT OF SERVICE AS NECESSARY TO COMPLETE WORK. F. WHERE APPLICABLE, THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE OWNER AND GENERAL TRADE FOR ANY WALL AND CEILING OPENINGS IN WHICH PLUMBING WORK IS TO BE PERFORMED. GENERAL TRADE SHALL BE RESPONSIBLE FOR PATCHING SUCH WALL AND CEILING OPENINGS TO MATCH EXISTING ONCE PLUMBING INSTALLATION HAS BEEN COMPLETED. WHERE PLUMBING CONTRACTOR IS PRIME, THEY WILL BE RESPONSIBLE FOR ARRANGING ALL WORK DESCRIBED ABOVE AND INCLUDE RELATED COST IN BID. G. WHERE APPLICABLE THE PLUMBING CONTRACTOR SHALL DEMARCATE EXISTING CONCRETE FLOOR AREAS FOR SAW CUT AND REMOVAL BY GENERAL TRADE. PLUMBING CONTRACTOR SHALL PROVIDE ALL EXCAVATION AND BACKFILL REQUIRED FOR INSTALLATION OF SYSTEM PIPING AND SPECIALTIES. GENERAL TRADE WILL BE RESPONSIBLE FOR PATCHING FLOOR AREAS FLUSH TO MATCH WITH EXISTING FLOOR ONCE PLUMBING INSTALLATION HAS BEEN COMPLETED. WHERE PLUMBING CONTRACTOR IS PRIME, THEY WILL BE RESPONSIBLE FOR ARRANGING ALL WORK DESCRIBED ABOVE AND INCLUDE RELATED COST IN BID. A. WORK SHALL BE PERFORMED BY A LICENSED PLUMBER OF THE STATE OF COLORADO. B. MATERIALS, INSTALLATION AND TESTING SHALL BE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF STATE AND LOCAL CODE PROCEDURES, METHODS AND REQUIREMENTS, INCLUDING THE MOST STRINGENT OF HEALTH AND SAFETY STANDARDS AS REQUIRED AND AS INTERPRETED BY THE AUTHORITY HAVING JURISDICTION. APPLICABLE CODES AND STANDARDS INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: "COLORADO STATE PLUMBING CODE" 2019 EDITION "INTERNATIONAL PLUMBING CODE" 2018 EDITION "INTERNATIONAL FUEL GAS CODE" 2018 EDITION "INTERNATIONAL ENERGY CONSERVATION CODE" 2018 EDITION "NFPA 54 - NATIONAL FUEL GAS CODE" APPLICABLE LOCAL AND MUNICIPAL CODES AND ORDINANCES. C. MEANING AND INTENT OF DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND PLUMBING SYSTEMS ARE SHOWN IN SCHEMATIC FORM. DRAWINGS DO NOT SHOW EVERY PLUMBING SYSTEM COMPONENT AND SHOULD BE FOLLOWED AS CLOSELY AS CIRCUMSTANCES WILL PERMIT. PLUMBING SYSTEM INSTALLATIONS RELATED TO THIS PROJECT SHALL BE PROVIDED TO MEET THE INTENT AND MEANING OF THE DRAWINGS IN COMPLIANCE WITH APPLICABLE CODES, AND STANDARDS. WHERE APPLICABLE THE PLUMBING CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO INSTALLATION. REPORT ANY QUESTIONS, OR CONCERNS TO THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH WORK. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. MINOR CHANGES IN LOCATIONS OF PLUMBING EQUIPMENT, &/OR SYSTEMS FROM THOSE INDICATED ON DRAWINGS SHALL BE MADE WITHOUT EXTRA COST. A COMPLETE AND OPERATIONAL PLUMBING SYSTEM SHALL BE PROVIDED. D. THE PLUMBING CONTRACTOR SHALL REFER TO BOTH DRAWINGS AND SPECIFICATIONS FOR ALL PLUMBING CRITERIA REQUIRED FOR THIS PROJECT. E. PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL PLUMBING UTILITY SERVICES FROM 5'-0" OUTSIDE BUILDING FOUNDATION WALL TO WITHIN THE BUILDING UNLESS NOTED OTHERWISE ON PLANS. SEE SITE UTILITY PLANS FOR RELATED SITE UTILITY WORK BY OTHERS. F. COORDINATE ROUTING OF PIPING WITH ALL OTHER TRADES AND STRUCTURAL CONDITIONS TO AVOID ANY ROUTING CONFLICTS OR SERVICE INTERFERENCES. G. MAINTAIN A MINIMUM CLEARANCE IN FRONT OF AND FROM EITHER SIDE OF ELECTRICAL PANELS, EQUIPMENT, ETC., AS OUTLINED IN NEC STANDARDS. PIPE SYSTEMS SHALL NOT BE ROUTED DIRECTLY OVER PANELS, EQUIPMENT, ETC. H. INCLUDE IN BID, ALL LICENSE, PERMIT, INSPECTION AND OTHER FEES REQUIRED BY UTILITY COMPANIES OR AUTHORITIES HAVING JURISDICTION REQUIRED FOR COMPLETION OF WORK SO THAT NO UNEXPECTED ADDITIONAL EXPENSES ARE INTRODUCED TO OWNER. I. ALL CLEANOUTS, VALVES, WATER HAMMER ARRESTORS, ETC. ARE TO BE ACCESSIBLE. EXTEND PIPING AND COORDINATE ACCESS PANEL SIZE AND LOCATION AS NECESSARY. J. PLUMBING CONTRACTOR SHALL CLEAN WORK AREA OF ALL DUST AND DEBRIS GENERATED BY THEIR WORK AT THE END OF EACH WORK DAY. K. ALL PLUMBING SYSTEM VALVES SHALL BE INSTALLED IN A LOCATION AND ORIENTATION THAT WILL PERMIT INTENDED USE. L. PROVIDE STOPS AND/OR ISOLATION VALVES TO EACH INDIVIDUAL FIXTURE, FIXTURE GROUP OR PIECE OF EQUIPMENT PER APPLICABLE CODES TO ALLOW FOR INDIVIDUAL SERVICING UNLESS NOTED OTHERWISE ON PLANS. M. SANITARY WASTE PIPING SHALL BE SLOPED AT 1/8-INCH PER FOOT MINIMUM FOR ALL PIPING 4-INCH AND LARGER AND AT 1/4-INCH PER FOOT MINIMUM FOR ALL PIPING 3- INCH AND SMALLER. N. INDIRECT DRAIN PIPING FROM FIXTURES, SPECIALTIES, AND EQUIPMENT SHALL BE ROUTED TO FLOOR DRAIN OR OTHER APPROVED RECEPTACLE AND TERMINATED WITH AN AIR GAP 2 TIMES THE DIAMETER OF THE DRAIN PIPING, BUT NOT LESS THAN 1 INCH GAP. SUPPORT PIPING SO DRAIN PIPING CANNOT BE DEFLECTED FROM DRAIN SOURCE. O. ALL VENTS FROM HORIZONTAL SOIL OR WASTE PIPE SHALL COME OFF TOP OR AT 45 DEGREE VERTICALLY FROM CENTER OF PIPE BEFORE OFFSETTING HORIZONTALLY TO RISER. P. ALL VENT TERMINATIONS SHALL BE COORDINATED WITH BUILDING OPENINGS, AIR INTAKES AND AIR EXHAUST OPENINGS. ADJUST VENT THROUGH ROOF LOCATIONS TO COMPLY WITH APPLICABLE CODE. Q. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING ALL HANGERS AND SUPPORTS ARE SECURELY ANCHORED OR ATTACHED TO BUILDING ELEMENTS ADEQUATE FOR INTENDED PLUMBING SYSTEM OR EQUIPMENT. R. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL NAIL PLATES WHERE PIPING PASSES THROUGH STUD(S) WITHIN 2" OF NAILING SURFACE TO PROTECT PIPE FROM NAILS OR DRYWALL SCREWS. S. PLUMBING CONTRACTOR SHALL PROVIDE APPROVED WATER HAMMER ARRESTORS IN WATER LINES SERVING QUICK-CLOSING VALVES, BATTERIED, OR BACK TO BACK FIXTURES WITH INDIVIDUAL ISOLATION VALVES. T. ALL NEWLY INSTALLED CIRCULATED HOT WATER SHALL BE WITHIN THE MAXIMUM ALLOWABLE PIPE LENGTH TO TERMINATE AT EACH FIXTURE, OR APPLIANCE AS OUTLINED IN THE INTERNATIONAL ENERGY CONSERVATION CODE. SPECIAL ATTENTION SHOULD BE PAID TO PUBLIC LAVATORIES WHERE MAXIMUM PIPE LENGTHS ARE LIMITED. REFER TO PLUMBING PLANS AND DETAILS FOR CLARIFICATION. U. ALL P-TRAPS FOR FLOOR DRAINS AND FLOOR SINKS SHALL BE DEEP SEAL TYPE. TRAPS SHALL MAINTAIN THE SEWER GAS SEALS BY MEANS OF A PRIMING DEVICE DESIGNED FOR SUCH PURPOSES OR BY OTHER METHODS AS ACCEPTABLE BY CODE AND AHJ. V. PLUMBING CONTRACTOR TO INSTALL, TEST, AND FIELD BALANCE APPROVED EQUIPMENT PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. W. PROVIDE INSULATION FOR THE PLUMBING PIPING SYSTEMS DESCRIBED IN THESE DRAWINGS AS PER THE IPC AND THE IECC. HWC HW 3-WAY CONTROL VALVE ANGLE GATE VALVE ANGLE GLOBE VALVE BALANCING/SHUTOFF VALVE BALL VALVE BUTTERFLY VALVE CHECK VALVE CALIBRATED BALANCING VALVE CONTROL VALVE EXPANSION VALVE GATE VALVE GLOBE VALVE QUICK OPEN VALVE SAFETY RELIEF VALVE SOLENOID VALVE BACKFLOW PREVENTER ECCENTRIC REDUCER CONCENTRIC REDUCER FLOW ARROW HOSE BIBB / SILLCOCK WALL CLEANOUT WATER CLOSET VENT THRU ROOF VACUUM BREAKER THERMOSTATIC MIXING VALVE TO BELOW SILLCOCK (EXTERIOR) PLUMBING CONTRACTOR MOP SINK BASIN LAVATORY HOT WATER RECIRCULATION PUMP HOSE BIBB (INTERIOR) HIGH AS POSSIBLE GENERAL CONTRACTOR FROM FLOOR ABOVE FLOOR CLEANOUT FURNISHED BY OTHERS ELECTRICAL CONTRACTOR BELOW GRADE BELOW FLOOR ABOVE FINISHED FLOOR ABOVE CEILING PLUMBING EQUIPMENT DESIGNATION AC AFF BF BG EC FBO FCO FFA GC HAP HB HWCP L MSB PC SC TB TMV VB VTR WC WCO SP SUMP PUMP UR URINAL EWC ELECTRIC WATER COOLER FD FLOOR DRAIN RD ROOF DRAIN CSS CLINICAL SERVICE SINK ET EXPANSION TANK FA FROM ABOVE FB FROM BELOW FFB FROM FLOOR BELOW FT FILL TANK GWH GAS WATER HEATER TFB TO FLOOR BELOW TFA TO FLOOR ABOVE WF WASH FOUNTAIN VACUUM RELIEF VALVE SH SHOWER EWH ELECTRIC WATER HEATER SS SERVICE SINK LT LAUNDRY TUB IM ICE MAKER HS HOSE STATION ESHSHOWER COMB. EMERGENCY EYE WASH/ EEWWASH EMERGENCY EYE DWDISHWASHER CF COMBINATION FIXTURE WB WASHER BOX SK SINK WS WATER SOFTENER BH BOOSTER HEATER PIPING SYSTEM DF DRINKING FOUNTAIN NOTE: NOT ALL SYMBOLS ARE USED IN CONSTRUCTION DOCUMENTS GAS COCK PLUG VALVE BAS BUILDING AUTOMATION SYSTEM BFP BACKFLOW PREVENTION DEVICE BJ BETWEEN JOISTS BOP BOTTOM OF PIPE BTUH BRITISH THERMAL UNITS PER HOUR COND CONDENSATE CP CONDENSATE PUMP CV CONTROL VALVE DN DOWN FPC FIRE PROTECTION SUBCONTRACTOR GPM GALLONS PER MINUTE MBH THOUSANDS OF BTU PER HOUR P PUMP PRV PRESSURE RELIEF VALVE TOP TOP OF PIPE NTS NOT TO SCALE GENERAL SF SQUARE FOOT SE SEWAGE EJECTOR EXISTING PLUMBING KEYNOTE KITCHEN EQUIPMENT DESIGNATION POINT OF NEW CONNECTION POINT OF TERMINATION/CAP NEW BOLD TEXT INDICATES NEW ITEM ITALIC TEXT INDICATES EXISTING ITEM # PRESSURE REDUCING VALVE (WATER) PRESSURE REGULATOR (GAS) PIPE ANCHOR PIPE GUIDES WALL CLEANOUT SUSPENDED CLEANOUT WCO WYE STRAINER WYE STRAINER W/DRAIN VALVE FLOOR DRAIN - ROUND OR SQUARE FLOOR CLEANOUT - ROUND OR SQUARE PIPE CAP PIPE TURNING DOWN PIPE TURNING UP TEE UP TEE DOWN DROP AND RUN DROP AND TURN TEE OFF TOP TEE OFF BOTTOM CROSS AND RISER PLAN 90° ELBOW PIPE TEE PIPE UNION FLEXIBLE PIPE CONNECTOR WATER METER PUMP AUTOMATIC AIR VENT PRESSURE SWITCH PRESSURE GAUGE THERMOMETER FLOW SWITCH TEMPERATURE SWITCH G NATURAL GAS ST STORM PD PUMP DISCHARGE OST OVERFLOW STORM GW GREASE WASTE OW OIL WASTE W SANITARY WASTE CD CONDENSATE DRAIN FS FLOOR SINK MC MECHANICAL CONTRACTOR ORD OVERFLOW ROOF DRAIN CA COMPRESSED AIR AW ACID WASTE N2 NITROGEN N2O NITROUS OXIDE MA MEDICAL AIR O2 OXYGEN WAGD WASTE ANESTHETIC GAS DISPOSAL VAC VACUUM V SANITARY VENT OV OIL VENT AV ACID VENT NPCW NONPOTABLE COLD WATER DI DE-IONIZED WATER SCW SOFTENED COLD WATER CW DOMESTIC COLD WATER RO REVERSE OSMOSIS WATER DOMESTIC HW RECIRCULATION DOMESTIC HOT WATER CO2 CARBON DIOXIDE HW (---) DOMESTIC HOT WATER (OTHER TEMP) OR OR YCO YARD CLEANOUT WFL WATER FILTER CO PIPE SLOPE ARROW F P T M L1 K22 GD GARBAGE DISPOSAL DS DOWNSPOUT NOZZLE AD AREA DRAIN SYMBOLS LEGEND ABBREVIATIONS DEMOLITION PIPING LHW LAB HOT WATER TW TEMPERED WATER LINE STYLE INDICATES DEMOLISHED ITEM LHWC LAB HW RECIRCULATION FCW FILTERED COLD WATER LCW LAB COLD WATER SHEET # DETAIL # DETAIL OR SECTION MARK ## # FIRE PROTECTION GENERAL RENOVATION NOTES A. DURING THE TIME THAT THE FIRE PROTECTION RENOVATION WORK IS BEING PERFORMED, AND THE FIRE PROTECTION SYSTEM IS DOWN AND OUT OF COMMISSION, THE FIRE PROTECTION CONTRACTOR SHALL HAVE SUFFICIENT PERSONNEL ONSITE TO KEEP A “FIRE WATCH” ON THE FACILITY. B. A FIRE PROTECTION WATCH IS IMPLEMENTED TO ENSURE THE FIRE SAFETY OF A BUILDING IN THE EVENT OF ANY ACT, OR SITUATION INSTIGATING AN INCREASED RISK TO PERSONS OR PROPERTY. THE TERM “FIRE WATCH” IS USED TO DESCRIBE A DEDICATED PERSON OR PERSONS WHO’S SOLE RESPONSIBILITY IS TO LOOK FOR FIRES WITHIN AN ESTABLISHED AREA. C. IN THE OPINION OF THE FIRE AND LIFE-SAFETY GROUP (FLS) OF FACTORY MUTUAL (FM), ANY REQUIRED FIRE PROTECTION SYSTEM THAT IS OUT OF SERVICE FOR MORE THAN 4 HOURS AND OCCUPIED IS REQUIRED TO ESTABLISH A FIRE WATCH. FOR THE PERSON OR PERSONS ASSIGNED TO THE FIRE WATCH, THIS MUST BE THEIR ONLY JOB DUTY DURING THE TIME PERIOD OF THE FIRE PROTECTION RENOVATION WORK. D. IN ADDITION THE BUILDING OWNER IS REQUIRED TO HAVE AN IMPAIRMENT COORDINATOR. THE OUT OF SERVICE EQUIPMENT MUST BE TAGGED “OUT OF SERVICE”. AN OUT OF SERVICE TAG MUST BE PLACED AT THE FIRE ALARM PANEL AND THE FIRE DEPARTMENT CONNECTION (REFERENCE INTERNATIONAL FIRE CODE- CHAPTER 9, SECTION 901.7). E. FIRE WATCH PERSONNEL ARE TO KEEP WATCH FOR FIRES IN THE GENERAL AREA OF PERFORMANCE, THE PERSONS PERFORMING THE FIRE WATCH ARE NOT PERMITTED TO PERFORM ANY OTHER DUTIES. F. FIRE WATCH PERSONNEL ARE TO HAVE FIRE EXTINGUISHING EQUIPMENT READILY AVAILABLE AND TO BE TRAINED IN ITS USE. G. THE QUANTITY OF PERSONNEL INVOLVED IN THE FIRE WATCH IS TO BE ADEQUATE SUCH THAT EACH FLOOR, LEVEL, AND ROOM OF THE FIRE AREA IS COVERED. H. IN GENERAL, A FIRE WATCH IS TO FULFILL THE INTENT OF NFPA-72 AS FOLLOWS: 1. NOTIFY OCCUPANTS TO EVACUATE WHEN THERE IS A FIRE IN THE BUILDING; 2. NOTIFY THE CENTRAL MONITORING STATION TO INITIATE EMERGENCY PERSONNEL RESPONSE; 3. ACTIVATE FIRE PROTECTION SYSTEMS IN ORDER TO RELEASE DOOR HOLDERS, CLOSE SMOKE DAMPERS, AND SHUT DOWN FANS. I. IF BUILDING OCCUPANTS ASSIST WITH FIRE WATCH DUTIES, THE PROCEDURES FOR CONTACTING EMERGENCY PERSONNEL AND EVACUATING THE BUILDING ARE TO BE DISTRIBUTED TO BUILDING OCCUPANTS. FOR PLANNED OUTAGES, THE PROCEDURES ARE TO BE SENT TO THE BUILDING OWNER FOR DISTRIBUTION. A. THE FIRE PROTECTION CONTRACTOR SHOULD USE NFPA-13 (CURRENT EDITION), “PLANS AND CALCULATIONS” AS A GUIDELINE WHEN PREPARING SUBMITTALS FOR REVIEW. DISREGARD ONLY THOSE ITEMS NOT APPLICABLE TO THE INDIVIDUAL BUILDING SYSTEM. FIRE PROTECTION MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA-13 FOR THE INSTALLATION OF AUTOMATIC SPRINKLER SYSTEM. B. THE FIRE PROTECTION CONTRACTOR SHALL COMPLY WITH THE INTERNATIONAL BUILDING CODE (LATEST ADOPTED EDITION). INSTALLATION SHALL MEET THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. C. IT IS THE CONTRACTOR'S RESPONSIBILITY TO HYDRAULICALLY CALCULATE SPRINKLER REQUIREMENTS PER THE APPROPRIATE HAZARD OCCUPANCY AND PROVIDE ACTUAL NUMBER OF HEADS, REQUIRED SPACING AND PIPE ROUTING AS REQUIRED FOR CLEARANCE WITH STRUCTURAL CONDITIONS AND OTHER TRADES TO PROVIDE A COMPLETE AND OPERABLE SYSTEM IN ACCORDANCE WITH IFC, NFPA AND AUTHORITY HAVING JURISDICTION REQUIREMENTS. D. SPRINKLER CONTRACTOR SHALL DESIGN THE SYSTEM AND ROUTE PIPING AS REQUIRED FOR CONFORMANCE WITH ACTUAL BUILDING CONDITIONS AND NFPA REQUIREMENTS. COORDINATE SPRINKLER WORK WITH ALL OTHER TRADES TO AVOID CONFLICT. E. SUPPORT ALL NEW PIPING AND EQUIPMENT FROM STRUCTURE ABOVE AS REQUIRED. CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTAL STEEL TO SPAN BETWEEN PRIMARY BUILDING STRUCTURAL MEMBERS. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE DESIGN OF SUPPLEMENTAL STEEL AND SUPPORTS INCLUDING REACTION LOADS AT PRIMARY BUILDING STRUCTURAL MEMBERS. F. PROVIDE ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, ETC. REQUIRED FOR COMPLETE AND FUNCTIONAL SYSTEM AS SPECIFIED AND INDICATED ON THE DRAWINGS. G. INCLUDE IN BID, ALL LICENSE, PERMIT, INSPECTION, AND OTHER FEES REQUIRED BY UTILITY COMPANIES OR AUTHORITIES HAVING JURISDICTION REQUIRED FOR COMPLETION OF WORK SO NO ADDITIONAL EXPENSES ARE INTRODUCED TO OWNER. H. PROMPTLY INFORM THE ENGINEER, IN WRITING, OF ANY DEVIATIONS IN THE CONTRACT DOCUMENTS FROM REQUIREMENTS OF LOCAL UTILITIES, MUNICIPALITIES, STATE OR FEDERAL LAWS AND REGULATIONS. PERFORM WORK IN ACCORDANCE WITH SUCH REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. I. FIRE PROTECTION CONTRACTOR SHALL SUBMIT ONE COMPLETE SET OF AUTOMATIC SPRINKLER SYSTEM DRAWINGS, HYDRAULIC CALCULATIONS, CURRENT WATER FLOW TEST, AND EQUIPMENT DATA BROCHURES AS PREPARED BY (OR PREPARED UNDER THE SUPERVISION OF) A PROFESSIONAL ENGINEER WHO SHALL BE SEALING THE AFOREMENTIONED SYSTEM DRAWINGS. THE SUBMITTAL SHALL BE SENT TO ALL AUTHORITIES HAVING JURISDICTION FOR REVIEW AND APPROVAL. SYSTEM SHALL ALSO BE IN COMPLIANCE WITH ALL REQUIRED PLUMBING CODES. J. ALL EXPENSES CARRIED BY THE A/E IN TROUBLESHOOTING SYSTEM(S) PROBLEMS CAUSED BY INADEQUATE WORKMANSHIP, LACK OF TECHNICAL EXPERTISE OR OTHER FORMS OF POOR PERFORMANCE ON THE PART OF A CONTRACTOR, SHALL BE BORN BY THAT CONTRACTOR. K. PROVIDE FIRE STOP / SEALANT AT ALL PIPE PENETRATIONS THROUGHOUT FIRE RATED WALLS. REVIEW ARCHITECTURAL PLANS PRIOR TO BIDDING AND INDICATE FIRE-RATED PENETRATION LOCATIONS ON SPRINKLER LAYOUT SUBMITTAL. L. FIRE PROTECTION CONTRACTOR SHALL FURNISH AND INSTALL ARMOVER SUPPORTS FOR ALL END OF LINE BRANCH LINES PER NFPA-13, SECTION: 9.2.3.4. REFER TO A.9.2.3.4.3(B) FOR ACCEPTABLE. M. ALL DROPS TO SPRINKLER HEADS SHALL TEE / ELBOW OFF TOP OF BRANCH PIPE, EXCEPT WHERE STRUCTURAL, ARCHITECTURAL OR MECHANICAL EQUIPMENT CONDITIONS PRECLUDE CONVENTIONAL INSTALLATION. N. THE CONTRACTOR SHALL VERIFY THE EXACT EXISTING CONDITIONS, INCLUDING ANY PERCEIVED CONCEALED SPACES, AND THE BUILDING TYPE AND CONSTRUCTION AS OUTLINED IN THE INTERNATIONAL BUILDING CODE, PRIOR TO THE START OF WORK. REFER TO THE INTERNATIONAL BUILDING CODE, ESPECIALLY CHAPTERS 6 (TYPES OF CONSTRUCTION) AND CHAPTER 9 (FIRE PROTECTION SYSTEMS), NFPA 13, AND THE PROJECT SPECIFICATIONS FOR OTHER FIRE PROTECTION REQUIREMENTS. FIRE PROTECTION BUILDING AND OCCUPANT SAFETY FOR THE INTERRUPTION OF FIRE PROTECTION SERVICE DATE: DRAWN: REVIEWED: SHEET TITLE: SHEET NUMBER: PROJECT NO.: PROJECT: ISSUE: # DATE: DESCRIPTION: NOT FOR CONSTRUCTION DESIGNED: 4/7/2020 10:16:29 AM P0.1 GENERAL INFORMATION BAJ CRF 0200100.04 Downtown Transit Center - Restroom Upgrades City of Fort Collins 250 N. Mason St, Fort Collins, CO 04.08.2020 JMB 90% CD 22x10 R 18"ø 16"ø 10"ø 12x8 S 265 12x8 S 265 ON ROOF 1 6"ø S 50 22x10 R 8"ø S 230 18"ø 16"ø 10"ø 12x8 S 265 12x8 S 265 36" MAX. 36" MAX. 36" MAX. 36" MAX. FLEXFLOW ELBOW AS MANUFACTURED BY THERMAFLEX SHEET METAL PLENUM MANUAL VOLUME DAMPER (TYP) BRANCH DUCT "SPIN-IN" TAKEOFF (TYP) SUPPLY AIR TRUNK DUCT APPLICATION NOTES: 1. FLEXIBLE DUCTWORK IS INTENDED FOR THE SOLE PURPOSE OF DIFFUSER ALIGNMENT. 2. UNDER NO CIRCUMSTANCE WILL THE USE OF FLEXIBLE DUCT BE ALLOWED IN NEGATIVE PRESSURE APPLICATIONS. 3. FLEXIBLE DUCTWORK MAY BE INSTALLED ONLY ABOVE ACCESSIBLE CEILINGS. TOP TAKEOFF SIDE TAKEOFF - ROUND BOTTOM TAKEOFF 36" MAX. 36" MAX. DESIGNER'S NOTE: FLEXFLOW ELBOW SUPPORT AND SHEET METAL PLENUM NOT ALLOWABLE ON ALL PROJECTS 36" MAX. 4" MIN. SIDE TAKEOFF - ROUND CONDUIT TO WIRING POST BY EC DAMPER BY FAN MANUFACTURER DISCONNECT BY FAN MANUFACTURER WITHIN HOUSING PREFABRICATED ROOF CURB REMOVABLE, SPUN ALUMINUM HOUSING NON-FERROUS BIRD SCREEN WIRING POST SHEET METAL PLENUM. SEAL LOWER 6 INCHES WATERTIGHT. BRANCH DUCT ROOF SYSTEM - REFER TO ARCHITECTURAL DETAILS DATE: DRAWN: REVIEWED: SHEET TITLE: SHEET NUMBER: PROJECT NO.: PROJECT: ISSUE: # DATE: DESCRIPTION: NOT FOR CONSTRUCTION DESIGNED: 4/7/2020 5:34:49 PM M1.1 DEMO AND NEW FLOORPLAN, NOTES, AND DETAILS BAJ CRF 0200100.04 Downtown Transit Center - Restroom Upgrades City of Fort Collins 250 N. Mason St, Fort Collins, CO 04.08.2020 BEB 90% CD 0 2 4 8 NORTH TRUE K. MECHANICAL SYSTEMS HAVE BEEN DESIGNED BASED UPON THE 2018 INTERNATIONAL MECHANICAL CODE, 2018 INTERNATIONAL ENERGY CONSERVATION CODE. J. DO NOT INSULATE EXPOSED SPIRAL DUCT AND EXHAUST DUCT UNLESS OTHERWISE NOTED. I. INSTALL DUCTS, UNLESS OTHERWISE INDICATED, VERTICALLY AND HORIZONTALLY, PARALLEL AND PERPENDICULAR TO BUILDING LINES; AVOID DIAGONAL RUNS UNLESS SPECIFICALLY INDICATED ON DRAWINGS. H. COORDINATE SIZE AND LOCATION OF ALL OPENINGS REQUIRED FOR DUCT AND PIPE PENETRATIONS THROUGH WALLS, FLOORS, AND ROOFS, WITH CONTRACTOR RESPONSIBLE FOR ROUGH FRAMING. COORDINATE LOCATION OF AIR INTAKES WITH EXHAUST AND PLUMBING VENTS SO THAT INTAKES ARE A MINIMUM OF 10 FEET FROM EXHAUST OPENINGS OR PLUMBING VENTS. G. FABRICATE RECTANGULAR DUCTS, ELBOWS, TRANSITIONS, OFFSETS, BRANCH CONNECTIONS, AND OTHER CONSTRUCTION WITH GALVANIZED, SHEET STEEL, ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS--METAL AND FLEXIBLE." COMPLY WITH REQUIREMENTS FOR METAL THICKNESS, REINFORCING TYPES AND INTERVALS, TIE-ROD APPLICATIONS, AND JOINT TYPES AND INTERVALS. F. COMPLY WITH NFPA 90B, "INSTALLATION OF WARM AIR HEATING AND AIR CONDITIONING SYSTEMS," UNLESS OTHERWISE INDICATED. E. COMPLY WITH NFPA 90A, "INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS," UNLESS OTHERWISE INDICATED. D. INSTALL EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER BUILDING SYSTEMS AND COMPONENTS. C. FINAL TEST AND BALANCE REPORT SHALL BE SUBMITTED FOR APPROVAL. B. ALL EXTERIOR WALL AND ROOF PENETRATIONS SHALL BE SEALED WATER TIGHT. A. ALL DUCTWORK IS SHOWN IN SCHEMATIC FORM. PROVIDE OFFSETS AS REQUIRED TO MEET SPACE REQUIREMENTS AND TO AVOID INTERFERENCE WITH OTHER TRADES AND FIELD CONDITIONS. EXACT LOCATION OF THE DUCTWORK MAY VARY ACCORDING TO THE COORDINATED SPACE REQUIREMENTS. EACH TRADE SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES. GENERAL NOTES SCALE: 1/4" = 1'-0" 2 VENTILATION PLAN KEYNOTES # 1 RETURN GRILLE OPEN TO SPACE ABOVE. 2 8x8 EXHAUST DUCT UP TO EF-10 ON ROOF. SCALE: 1/4" = 1'-0" 1 MECHANICAL DEMOLITION PLAN KEY PLAN SCALE: NOT TO SCALE 3 FLEXIBLE DUCT CONNECTIONS SCALE: NOT TO SCALE 4 DOWNFLOW ROOF EXHAUST FAN CWWATER DOMESTIC COLD CWP CONDENSER WATER PUMP CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY DC DRY COOLER DN DOWN DP DIFFERENTIAL PRESSURE DS DUCT SILENCER EA EXHAUST AIR EBB ELECTRIC BASEBOARD HEATER EF EXHAUST FAN EG EXHAUST GRILLE (LESS DAMPER) EHC ELECTRIC HEATING COIL EL ELEVATION ER EXHAUST REGISTER ERV ENERGY RECOVERY VENTILATOR ET EXPANSION TANK FA FRESH AIR FD FIRE DAMPER FDC FLEXIBLE DUCT CONNECTION FFA FROM FLOOR ABOVE FFB FROM FLOOR BELOW FPC FLEXIBLE PIPE CONNECTION FPT FAN POWERED AIR TERMINAL FT FINNED TUBE RADIATION GF GAS FURNACE GIH GRAVITY INTAKE HOOD GPM GALLONS PER MINUTE GR GLYCOL RETURN GS GLYCOL SUPPLY GUH GAS UNIT HEATER HU HUMIDIFIER HC HEATING COIL HCWR DUAL TEMPERATURE RETURN HCWS DUAL TEMPERATURE SUPPLY HP HEAT PUMP HPR HIGH PRESSURE STEAM RETURN HPS HIGH PRESSURE STEAM SUPPLY HRC HEAT RECOVERY COIL HS HUMIDITY SENSOR HWP HOT WATER PUMP HWR HOT WATER RETURN LOW PRESSURE STEAM SUPPLY LOW PRESSURE STEAM RETURN KITCHEN HOOD - COMMERCIAL HEAT EXCHANGER HOT WATER SUPPLY LPS LPR KH HX HWS THOUSANDS OF BTU PER HOUR MOTORIZED DAMPER MAKEUP AIR UNIT MIXED AIR MBH MD MAU MA OBD OPPOSED BLADE DAMPER P PUMP PBD PARALLEL BLADE DAMPER PRV PRESSURE RELIEF VALVE PS PRESSURE SWITCH PSI POUNDS PER SQUARE INCH PTAC RA RETURN AIR RF RETURN AIR FAN RG RETURN GRILLE (LESS DAMPER) RH ROOF HOOD RHC REHEAT COIL RLFA RELIEF AIR RPZ REDUCED PRESSURE BFP RR RETURN REGISTER (WITH DAMPER) RTU ROOFTOP AIR HANDLING UNIT SA SUPPLY AIR SAS SELF-ACTING SHUTTER SD SUPPLY DIFFUSER/SMOKE DAMPER SF SUPPLY FAN / SQUARE FOOT SFD SMOKE/FIRE DAMPER SG SUPPLY GRILLE SR SUPPLY REGISTER TCAC TEMP. CONTROL AIR COMPRESSOR TCAD TEMP. CONTROL AIR DRYER TDV TRIPLE DUTY VALVE TFA TO FLOOR ABOVE TFB TO FLOOR BELOW TOD TOP OF DUCT TOP TOP OF PIPE UC UNIT COOLER UFD UNDERFLOOR DUCT UH UNIT HEATER UV UNIT VENTILATOR VAV VARIABLE AIR VOLUME TERMINAL VD VOLUME DAMPER VFD VARIABLE FREQUENCY DRIVE AUTOMATIC AIR VENT TEMPERATURE SENSOR/SWITCH PRESSURE GAUGE THERMOMETER PIPE ANCHOR PIPE GUIDES MANUAL AIR VENT FLOW SENSOR/SWITCH PIPE EXPANSION JOINT PIPE UNION CONCENTRIC REDUCER ECCENTRIC REDUCER WYE STRAINER WYE STRAINER W/DRAIN VALVE DIRECTION OF FLOW STEAM BUCKET TRAP STEAM F&T TRAP BACKFLOW PREVENTER PIPE TURNING UP PIPE TURNING DOWN TEE OFF TOP TEE OFF BOTTOM PIPE TEE PIPE CAP PLAN 90 DEGREE ELBOW PLAN 45 DEGREE ELBOW PIPING SYSTEM (SOLID LINE) PIPING SYSTEM (DASHED LINE) MOTORIZED SHUTTER NOT TO SCALE MS NTS GENERAL HYDRONIC VENTILATION GENERAL NOTES COMMON REQUIREMENTS PIPING SYSTEM REQUIREMENTS DEMOLITION DESIGN CONDITIONS DUCTWORK REQUIREMENTS UFT UNDERFLOOR FAN TERMINAL HRV HEAT RECOVERY VENTILATOR (SENSIBLE) EUH ELECTRIC UNIT HEATER ESP EXTERNAL STATIC PRESSURE ISP INTERNAL STATIC PRESSURE TSP TOTAL STATIC PRESSURE PUMP PC PLUMBING CONTRACTOR EC ELECTRICAL CONTRACTOR GC GENERAL CONTRACTOR FLEXIBLE PIPE CONNECTOR FCU FAN COIL UNIT AL ALUMINUM VRP VERTICAL RADIANT PANEL WAC WINDOW / WALL AIR CONDITIONER DAC DOOR AIR CURTAIN DH DEHUMIDIFIER DOAS DEDICATED OUTDOOR AIR SYSTEM DSU DUCTLESS SPLIT UNIT DX DX COOLING COIL ERP ELECTRIC RADIANT PANEL GRH GAS RADIANT HEATER L LOUVER PDH POOL ROOM DEHUMIDIFIER PACKAGED TERMINAL AIR CONDITIONER RP RADIANT PANEL S1 12x12 250 EXISTING EQUIPMENT TYPE EQUIPMENT MARK SHEET # DETAIL # AIRFLOW IN CFM THROAT SIZE MECHANICAL EQUIPMENT TAG AIR TERMINAL DESIGNATION KEYNOTE DETAIL OR SECTION MARK POINT OF NEW CONNECTION CAP EXISTING PIPE OR DUCT BOLD TEXT INDICATES PROPOSED ITEM ITALIC TEXT INDICATES EXISTING ITEM NEW ## # # PRESSURE/TEMPERATURE PLUG AHU-1 GUARD LOCKABLE GUARD WHERE INDICATED EQUIPMENT TO BE CONTROLLED GUARD TEMP HUMID CO ELEMENT TO BE MONITORED LOCKABLE GUARD WHERE INDICATED HUMIDISTAT THERMOSTAT SENSOR SUPPLY DIFFUSER/REGISTER RETURN REGISTER/GRILLE EXHAUST REGISTER/GRILLE DIFFUSER AIRFLOW PATTERN IF OTHER THAN 4-WAY BLOW FLEXIBLE BRANCH RUNOUT TO SUPPLY DIFFUSER, 36" MAX LENGTH CEILING RETURN REGISTER WITH LINED DUCT FOR SOUND ATTENUATION OPEN TO CEILING PLENUM FLEXIBLE DUCT CONNECTION TO EQUIPMENT OR BETWEEN DUCTS VOLUME DAMPER MOTORIZED DAMPER FIRE DAMPER SMOKE DAMPER COMBINATION FIRE/SMOKE DAMPER SUPPLY AIR DUCT TOWARDS SUPPLY AIR DUCT AWAY RETURN/OUTDOOR AIR DUCT TOWARDS RETURN/OUTDOOR AIR DUCT AWAY TRANSFER AIR A. THIS FACILITY HAS BEEN DESIGNATED A "SMOKE-FREE" ENVIRONMENT. NO MECHANICAL VENTILATION PROVISIONS HAVE BEEN MADE TO ACCOMMODATE TOBACCO USAGE BY THE BUILDING OCCUPANTS B. ALL MECHANICAL SYSTEMS SHALL BE INSTALLED TO THE SATISFACTION OF THE LOCAL CODE AUTHORITIES HAVING JURISDICTION A. INSTALL EQUIPMENT TO ALLOW MAXIMUM POSSIBLE HEADROOM UNLESS SPECIFIC MOUNTING HEIGHTS ARE INDICATED B. INSTALL EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER BUILDING SYSTEMS AND COMPONENTS IN EXPOSED INTERIOR SPACES, UNLESS OTHERWISE INDICATED C. INSTALL HVAC EQUIPMENT TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR OR REPLACEMENT OF COMPONENTS. CONNECT EQUIPMENT FOR EASE OF REMOVAL, WITH MINIMUM INTERFERENCE TO OTHER INSTALLATIONS D. ALL MECHANICAL EQUIPMENT WITH THE EXCEPTION OF AIR HANDLING UNITS, SUPPORTED FROM FLOOR STRUCTURE SHALL BE MOUNTED ON 4" THICK CONCRETE HOUSEKEEPING PADS UNLESS NOTED OTHERWISE. AIR-HANDLING UNITS SHALL BE MOUNTED ON 6" THICK CONCRETE HOUSEKEEPING PADS TO ACCOMMODATE PROPER TRAPPING OF THE CONDENSATE DRAIN E. AIR FILTERS SHALL BE REPLACED IN ALL AIR HANDLING EQUIPMENT EMPLOYING SUCH PRIOR TO FINAL COMPLETION AND OWNER OCCUPANCY F. THE INSTALLING CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ALL MECHANICAL EQUIPMENT PUT INTO OPERATION PRIOR TO THE INSTALLATION OF A WORKING CONTROL SYSTEM, TESTING, AND BALANCING, AND SUBSTANTIAL COMPLETION. ALL RETURN AND EXHAUST DUCT OPENINGS SHALL BE COVERED WITH ROLL TYPE FILTER MEDIA DURING SUCH TEMPORARY OPERATION. OPERATION OF THE MECHANICAL EQUIPMENT PRIOR TO FINAL COMPLETION SHALL NOT IMPACT THE EQUIPMENT WARRANTY. MINIMUM 1-YEAR FROM SUBSTANTIAL COMPLETION UNLESS SPECIFIED OTHERWISE G. PROVIDE FLEXIBLE DUCT CONNECTION BETWEEN MOTOR DRIVEN MECHANICAL UNITS AND SHEET METAL SUPPLY, OUTDOOR AIR, EXHAUST, AND/OR RETURN AIR DUCTWORK CONNECTIONS H. PROVIDE FLEXIBLE PIPE CONNECTION BETWEEN MOTOR DRIVEN MECHANICAL UNITS AND CONNECTING PIPING I. BASIS OF DESIGN MECHANICAL EQUIPMENT IS AS SCHEDULED ON THE DRAWINGS. INSTALLING CONTRACTOR ASSUMES RESPONSIBILITY FOR COORDINATING PHYSICAL SPACE REQUIREMENTS OF EQUIVALENT CAPACITY MECHANICAL EQUIPMENT DEEMED ACCEPTABLE BY THE ENGINEER J. MECHANICAL EQUIPMENT FACTORY FINISH DAMAGED DURING THE COURSE OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITION PRIOR TO FINAL ACCEPTANCE A. DUCTWORK IS SHOWN IN SCHEMATIC FORM. ALL REQUIRED DUCT RISERS AND DROPS TO ALLOW GENERAL ROUTING DEPICTED MAY NOT BE SHOWN. PROVIDE OFFSETS AS REQUIRED TO MEET SPACE REQUIREMENTS AND TO AVOID INTERFERENCE WITH OTHER TRADES AND FIELD CONDITIONS. EXACT LOCATION OF THE DUCTWORK MAY VARY ACCORDING TO THE COORDINATED SPACE REQUIREMENTS. EACH TRADE SHALL BE TOTALLY RESPONSIBLE FOR COORDINATION WITH OTHER TRADES. NOTIFY ENGINEER OF CONDITIONS REPRESENTING SIGNIFICANT CHANGES TO THE DESIGNED ROUTING B. COMPLY WITH NFPA 90A, "INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS," UNLESS OTHERWISE INDICATED C. COMPLY WITH NFPA 90B, "INSTALLATION OF WARM AIR HEATING AND AIR CONDITIONING SYSTEMS," UNLESS OTHERWISE INDICATED D. FABRICATE RECTANGULAR DUCTS, ELBOWS, TRANSITIONS, OFFSETS, BRANCH CONNECTIONS, AND OTHER CONSTRUCTION WITH GALVANIZED, SHEET STEEL, ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS--METAL AND FLEXIBLE." COMPLY WITH REQUIREMENTS FOR METAL THICKNESS, REINFORCING TYPES AND INTERVALS, TIE-ROD APPLICATIONS, AND JOINT TYPES AND INTERVALS E. COORDINATE SIZE, QUANTITY, AND LOCATION OF ALL OPENINGS REQUIRED FOR DUCT AND PIPE PENETRATIONS THROUGH WALLS, FLOORS, AND ROOFS, WITH CONTRACTOR RESPONSIBLE FOR ROUGH FRAMING. COORDINATE LOCATION OF AIR INTAKES WITH EXHAUST AND PLUMBING VENTS SO THAT INTAKES ARE A MINIMUM OF 10 FEET FROM EXHAUST OPENINGS OR PLUMBING VENTS F. INSTALL DUCTS IN LONGEST LENGTH POSSIBLE AND FEWEST POSSIBLE JOINTS. INSTALL FABRICATED FITTINGS FOR CHANGES IN DIRECTIONS, CHANGES IN SIZE AND SHAPE, AND CONNECTIONS G. INSTALL DUCTS, UNLESS OTHERWISE INDICATED, VERTICALLY AND HORIZONTALLY, PARALLEL AND PERPENDICULAR TO BUILDING LINES; AVOID DIAGONAL RUNS UNLESS SPECIFICALLY INDICATED ON DRAWINGS H. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING MOUNTED DEVICES. COORDINATE MECHANICAL CEILING DEVICES SUCH AS DIFFUSERS AND REGISTERS WITH LIGHT FIXTURES, SPEAKERS, SPRINKLER HEADS, ETC. I. ELECTRICAL EQUIPMENT SPACES: ROUTE DUCTWORK TO AVOID PASSING THROUGH TRANSFORMER VAULTS AND ELECTRICAL EQUIPMENT SPACES AND ENCLOSURES. AVOID ROUTING DUCTWORK DIRECTLY ABOVE ELECTRICAL EQUIPMENT UNLESS SPECIFICALLY INDICATED ON THE MECHANICAL DRAWINGS J. NON-FIRE-RATED PARTITION PENETRATIONS: WHERE DUCTS PASS THROUGH INTERIOR PARTITIONS AND ARE EXPOSED TO VIEW IN MECHANICAL ROOMS, CONCEAL SPACE BETWEEN CONSTRUCTION OPENING AND DUCT OR DUCT INSULATION WITH SHEET METAL FLANGES OF SAME METAL THICKNESS AS DUCT. OVERLAP OPENING ON FOUR SIDES BY AT LEAST 1-1/2 INCHES UNLESS INDICATED OTHERWISE K. FIRE-RATED PARTITION PENETRATIONS: WHERE DUCTS PASS THROUGH INTERIOR PARTITIONS, INSTALL APPROPRIATELY RATED FIRE DAMPER. FIRE DAMPER INSTALLATION MUST STRICTLY ADHERE TO MANUFACTURER'S WRITTEN INSTRUCTIONS L. PROVIDE MANUAL VOLUME-CONTROL BALANCING DAMPER AT ALL BRANCH DUCTS AND AT ALL OTHER LOCATIONS REQUIRED FOR A COMPLETE AND BALANCEABLE AIR DISTRIBUTION SYSTEM M. BALANCE ENTIRE AIR DISTRIBUTION SYSTEM TO AIRFLOW QUANTITIES INDICATED ON MECHANICAL DRAWINGS N. FLEXIBLE DUCTWORK SHALL BE ALLOWED ONLY IN POSITIVE PRESSURE APPLICATIONS AT SUPPLY BRANCH RUNOUTS TO DIFFUSERS ABOVE ACCESSIBLE CEILINGS. FLEXIBLE DUCTWORK SHALL NOT EXCEED 36" IN LENGTH. 90 DEGREE TURNS SHALL ONLY BE ALLOWED IF RETAINING BANDS EQUAL TO THERMAFLEX "FLEX-FLOW" ARE EMPLOYED. UNDER NO CIRCUMSTANCES SHALL FLEXIBLE DUCTWORK BE ALLOWED IN NEGATIVE PRESSURE APPLICATIONS A. VERIFY EXACT SIZE AND LOCATION OF EXISTING UTILITIES PRIOR TO START OF DEMOLITION WORK B. RELOCATE, REMOVE, AND ADJUST ALL MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO ACCOMPLISH SCOPE OF NEW WORK C. EXISTING MECHANICAL ITEMS ARE SHOWN IN SCHEMATIC FORM BASED UPON EXISTING CONSTRUCTION DOCUMENTS AND/OR FIELD INVESTIGATION D. REMOVE EXISTING PIPING AND DUCTWORK BACK TO LAST ACTIVE SERVICE AND CAP E. FIXTURES AND EQUIPMENT INDICATED TO BE REUSED OR SALVAGED SHALL REMAIN THE PROPERTY OF THE OWNER AND BE STORED IN A LOCATION AS DIRECTED BY OWNER'S REPRESENTATIVE F. IN LOCATIONS WHERE EXISTING CONSTRUCTION IS REMOVED AND NO ADDITIONAL CONSTRUCTION IS INDICATED, PATCH EXISTING CONSTRUCTION TO MATCH ADJACENT SURFACES AND FINISHES G. CONNECTIONS TO, AND SHUTDOWNS OF, EXISTING SYSTEMS SHALL BE COORDINATED WITH OWNER'S REPRESENTATIVE TO ALLOW MINIMUM INTERFERENCE WITH OWNER'S OPERATION AND DOWNTIME OF EXISTING UTILITIES. CONTRACTOR SHALL SUBMIT TO OWNER FOR REVIEW AND APPROVAL THE PROPOSED PHASING PLAN FOR CONNECTING NEW SERVICES TO EXISTING A. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PIPING SYSTEMS. INDICATED LOCATIONS AND ARRANGEMENTS WERE USED TO SIZE PIPE AND CALCULATE FRICTION LOSS, EXPANSION, PUMP SIZING, AND OTHER DESIGN CONSIDERATIONS. INSTALL PIPING AS INDICATED UNLESS DEVIATIONS TO LAYOUT ARE APPROVED BY ENGINEER B. DELIVER PIPES AND TUBES WITH FACTORY-APPLIED END CAPS. MAINTAIN END CAPS THROUGH SHIPPING, STORAGE, AND HANDLING TO PREVENT PIPE END DAMAGE AND TO PREVENT ENTRANCE OF DIRT, DEBRIS, AND MOISTURE C. COORDINATE PIPE ROUTINGS, CHASES, AND OPENINGS IN BUILDING STRUCTURE WITH ALL TRADES DURING PROGRESS OF CONSTRUCTION. COORDINATE INSTALLATION OF REQUIRED SUPPORTING DEVICES AND SET SLEEVES IN POURED-IN-PLACE CONCRETE AND OTHER STRUCTURAL COMPONENTS AS THEY ARE CONSTRUCTED D. INSTALL PIPING IN CONCEALED LOCATIONS, UNLESS OTHERWISE INDICATED AND EXCEPT IN EQUIPMENT ROOMS AND SERVICE AREAS. INSTALL PIPING INDICATED TO BE EXPOSED AND PIPING IN EQUIPMENT ROOMS AND SERVICE AREAS AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL RUNS ARE PROHIBITED UNLESS SPECIFICALLY INDICATED OTHERWISE E. INSTALL PIPING ABOVE ACCESSIBLE CEILINGS TO ALLOW SUFFICIENT SPACE FOR CEILING PANEL REMOVAL F. INSTALL PIPING TO PERMIT VALVE SERVICING G. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS H. INSTALL PIPING TO ALLOW APPLICATION OF INSULATION I. INSTALL ESCUTCHEONS FOR PENETRATIONS OF FINISHED WALLS, CEILINGS, AND FLOORS J. SLEEVES ARE NOT REQUIRED FOR CORE-DRILLED HOLES. K. PERMANENT SLEEVES ARE NOT REQUIRED FOR HOLES FORMED BY REMOVABLE PE SLEEVES L. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS AND CONCRETE FLOOR AND ROOF SLABS M. UNDERGROUND, EXTERIOR-WALL PIPE PENETRATIONS: INSTALL CAST-IRON "WALL PIPES" FOR SLEEVES. SEAL PIPE PENETRATIONS USING MECHANICAL SLEEVE SEALS. SELECT SLEEVE SIZE TO ALLOW FOR 1-INCH ANNULAR CLEAR SPACE BETWEEN PIPE AND SLEEVE FOR INSTALLING MECHANICAL SLEEVE SEALS N. FIRE-BARRIER PENETRATIONS: MAINTAIN INDICATED FIRE RATING OF WALLS, PARTITIONS, CEILINGS, AND FLOORS AT PIPE PENETRATIONS. SEAL PIPE PENETRATIONS WITH FIRESTOP MATERIALS. O. VERIFY FINAL EQUIPMENT LOCATIONS FOR ROUGHING-IN. MECHANICAL EQUIPMENT INSTALLATION PRESSURE SENSOR/SWITCH EXHAUST AIR DUCT TOWARDS EXHAUST AIR DUCT AWAY TJ THROUGH JOISTS CHS CHILLED WATER SUPPLY CO2 3-WAY CONTROL VALVE ANGLE GATE VALVE ANGLE GLOBE VALVE BALANCING/SHUTOFF VALVE BALL VALVE BUTTERFLY VALVE CHECK VALVE CALIBRATED BALANCING VALVE CONTROL VALVE EXPANSION VALVE GATE VALVE GLOBE VALVE QUICK OPEN VALVE SAFETY RELIEF VALVE SOLENOID VALVE VACUUM RELIEF VALVE GAS COCK PLUG VALVE PRESSURE REDUCING VALVE (WATER) PRESSURE REGULATOR (GAS) PIPE SLOPE ARROW WALL SWITCH H S T CFM F P T 12x8Φ FLAT OVAL DUCT 12"ø ROUND DUCT 12x8 RECTANGULAR DUCT AHU 1 M METER MC MECHANICAL CONTRACTOR SYMBOLS LEGEND NOTE: NOT ALL SYMBOLS ARE USED IN CONSTRUCTION DOCUMENTS HVAC DESIGN LOAD CALCULATIONS ARE BASED ON THE FOLLOWING CLIMATE DATA: CITY AND STATE: FORT COLLINS WINTER OUTDOOR AMBIENT DB: -2.6 SUMMER OUTDOOR AMBIENT DB/WB: 90.1/60.9 MECHANICAL SYSTEMS HAVE BEEN DESIGNED BASED UPON THE 2018 INTERNATIONAL MECHANICAL CODE, 2018 INTERNATIONAL ENERGY CONSERVATION CODE, NATIONAL FIRE PROTECTION (NFPA) STANDARDS, AND ACCEPTED AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR-CONDITIONING ENGINEERS (ASHRAE) ACCEPTED STANDARDS AND PRACTICES ABBREVIATIONS LINE STYLE INDICATES DEMOLISHED ITEM DATE: DRAWN: REVIEWED: SHEET TITLE: SHEET NUMBER: PROJECT NO.: PROJECT: ISSUE: # DATE: DESCRIPTION: NOT FOR CONSTRUCTION DESIGNED: 4/8/2020 2:09:34 PM M0.1 GENERAL INFORMATION Drawn By Approver 0200100.04 Downtown Transit Center - Restroom Upgrades City of Fort Collins 250 N. Mason St, Fort Collins, CO 04.08.2020 Designer 90% CD 14,957A 1#2/0 X 13,649A DO NOT TERMINATE IG CONDUCTOR IN PANEL P1 (4#3, 1#8G, 1-1/4"C) (4#4/0, 1#4IG, 1#4G, 2-1/2"C) LIEBERT AVC SERIES OR APPROVED EQUAL LOAD SUMMARY: P2 EXISTING LOAD: 13400 VA LOAD REMOVED: 1260 VA NEW LOAD: 360 VA TOTAL LOAD: 12500 VA TOTAL LOAD: 34.72 A LOAD SUMMARY: P1 EXISTING LOAD: 101400 VA LOAD REMOVED (P2 AND P3): 1508 VA NEW LOAD (P2, P3, AND EF-10): 1040 VA TOTAL LOAD: 100932 VA TOTAL LOAD: 280.37 A LOAD SUMMARY: P3 EXISTING LOAD: 21800 VA LOAD REMOVED: 248 VA NEW LOAD: 152 VA TOTAL LOAD: 21704 VA TOTAL LOAD: 60.29 A DATE: DRAWN: REVIEWED: SHEET TITLE: SHEET NUMBER: PROJECT NO.: PROJECT: ISSUE: # DATE: DESCRIPTION: NOT FOR CONSTRUCTION DESIGNED: 4/8/2020 10:32:48 AM E1.1 ELECTRICAL PLANS JPG APC 0200100.04 Downtown Transit Center - Restroom Upgrades City of Fort Collins 250 N. MASON ST. FORT COLLINS, CO 04.08.2020 INM 90% CD 0 4 8 16 NORTH PLAN B. CONTRACTOR TO CONFIRM THAT ALL EXISTING CIRCUIT CONTINUITY IS MAINTAINED. A. EXISTING PANNEL/CIRCUIT NUMBERS SHOWN ARE BASED ON EXISTING DRAWINGS. CONTRACTOR TO CONFIRM THAT INFORMATION SHOWN ON DEMOLITION DRAWINGS ARE ACCURATE. GENERAL NOTES # SCALE: 1/4" = 1'-0" 2 LIGHTING PLAN KEYNOTES 1 THIS ROOM IS NOT IN SCOPE OF WORK. ALL EQUIPMENT AND FIXTURES ARE EXISTING TO REMAIN. 2 DEMOLISH ALL EXISTING ELECTRICAL EQUIPMENT AND LIGHTING FIXTURES IN THIS SPACE. SEE NEW WORK PLANS E1.1/1 AND E1.1/2 ON THIS SHEET. REUSE EXISTING CONDUCTORS AND CONDUITS WHERE APPROPRIATE. 3 MOUNT TYPE B FIXTURE HORIZONTALLY AND CENTERED ABOVE MIRROR. 4 CIRCUIT EF-10 TO P1-24. IF CIRCUIT IS NOT AVAILABLE, CIRCUIT TO OPEN SPACE OR 15A/1P SPARE AVAILABLE IN PANEL P1. SCALE: 1/4" = 1'-0" 1 POWER AND SYSTEMS PLAN SCALE: 1/4" = 1'-0" 3 ELECTRICAL DEMOLITION PLAN KEY PLAN SCALE: NOT TO SCALE 4 EXISTING ONE-LINE DIAGRAM (FOR REFERENCE ONLY) LUMINAIRE SCHEDULE TYPE MANUFACTURER CATALOG NUMBER LAMP DESCRIPTION VOLTAGE LOAD (VA) FINISH MOUNTING DESCRIPTION A PRESCOLITE LC8SL SERIES 3500K, 90+ CRI, LED 120 V 22 WHITE RECESSED 8" DOWNLIGHT, 0-10V DIMMING, 1000 LM B COLUMBIA LIGHTING CWM SERIES 3500K, LED 120 V 32 WHITE HORIZONTAL ABOVE MIRROR 4' VANITY LIGHT, 3240 LM, FROSTED RECTILINEAR LENS, FLAT ALUMINUM END CAPS, 0-10V DIMMING, WITH EMERGENCY BATTERY PACK. B. FOR APPROVAL OF FIXTURES FROM MANUFACTURERS OTHER THAN THOSE LISTED, PROPOSED FIXTURES SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER TEN BUSINESS DAYS PRIOR TO BID FOR REVIEW. FINAL DETERMINATION OF 'EQUAL' STATUS FOR BIDDING SHALL BE THE SOLE DETERMINATION OF THE ARCHITECT/ENGINEER. NOTES: A. REMOVE ALL FINGER PRINTS FROM LENSES, REFLECTORS, AND LOUVERS FOLLOWING LIGHT FIXTURE INSTALLATION. EQUIPMENT DATA SCHEDULE DESCRIPTION LOAD DATA DISCONNECT AT EQUIP. WIRE & CONDUIT REMARKS MARK EQUIPMENT FURNISHED BY INSTALLED BY LOCATION LOAD VOLTAGE PHASE DISC. TYPE DISC. SIZE FURNISHED BY INSTALLED BY EF 10 EXHAUST FAN MC MC ROOF 1/8 HP 120 1 SW -- EC EC 2#12, 1#12G, 3/4"C N. FIELD ADJUST ALL LUMINAIRES REQUIRING AIMING WITH THE OWNER PRESENT AND TO THEIR SATISFACTION. M. THE ELECTRICAL CONTRACTOR SHALL BE HELD FINANCIALLY RESPONSIBLE FOR ANY AND ALL COSTS OF THE ENGINEERS TIME REQUIRED TO REVIEW AND RESEARCH NON-SPECIFIED EQUIPMENT SUBMITTED FOR SUBSTITUTION BY THE ELECTRICAL CONTRACTOR. THESE COSTS SHALL BE AUTOMATICALLY INVOICED TO THE CONTRACTOR UNLESS SUCH SUBSTITUTIONS FOLLOW THE GUIDELINES FOR SUBSTITUTION AND ARE WITHIN THE PROPER TIME FRAME AS OUTLINED IN OTHER SECTIONS OF THIS SPECIFICATION. L. ALL LUMINAIRES WITH EMERGENCY BATTERIES SHALL HAVE THE BATTERY CHARGER CIRCUITED TO THE AMBIENT LIGHTING CIRCUIT IN THE SPACE BUT SHALL BE UNSWITCHED. IF THE LUMINAIRE IS INDICATED AS SWITCHED, ONLY THE LUMINAIRE SHALL BE CONTROLLED BY THE SWITCHED CONDUCTORS (BATTERY CHARGER SHALL REMAIN UNSWITCHED). K. FINISH OF ALL LIGHTING FIXTURES IS SUBJECT TO ARCHITECT'S APPROVAL. SUBMIT SAMPLES IF REQUESTED. J. ALL RECESSED LUMINAIRES IN HARD CEILINGS SHALL HAVE FEED-THRU JUNCTION BOXES. I. ALL LIGHT FIXTURES SHALL BE EQUIPPED WITH A GREEN GROUND WIRE BONDED TO THE HOUSING. 1. ALL PENETRATIONS OF FIRE-RESISTIVE FLOORS OR SHAFT WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UNDERWRITERS' LABORATORIES LISTINGS FOR "THROUGH-PENETRATION FIRE STOP SYSTEMS." THE CONTRACTOR SHALL SUBMIT SHOP DRAWING DETAILS, FURNISHED BY THE MANUFACTURER OF THE FIRE STOP MATERIAL, WHICH SHOW COMPLETE CONFORMANCE TO THE UL LISTING AND SHALL BE SPECIFIC FOR EACH PENETRATION WITH ALL VARIABLES DEFINED. THESE FINAL AND APPROVED DRAWINGS SHALL BE READILY AVAILABLE TO THE LOCAL INSPECTORS AT ALL TIMES AT THE PROJECT SITE. H. REFER TO ARCHITECTURAL PLANS TO CONFIRM ALL FIRE-RATED CEILINGS AND WALLS. G. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR ACTUAL LAYOUT OF LIGHT FIXTURES AND CEILING TYPES. VERIFY CEILING TYPES PRIOR TO ORDERING FIXTURES. F. DRAWINGS SHOW EXISTING CONDITIONS OF THE SITE. AN ATTEMPT HAS BEEN MADE TO SHOW EXISTING BUILDING, SITE DETAILS, ETC., BUT ACCURACY CANNOT BE GUARANTEED. VERIFY EXACT LOCATIONS OF ALL CIRCUITS, CONDUITS, PIPING, EQUIPMENT, ETC. VERIFY ALL SITE AND BUILDING DETAILS. E. GROUT AND SEAL ALL CONDUIT PENETRATIONS OF WALLS AND FLOOR SLABS TO PRESERVE FIRE RATING AND WATERTIGHT INTEGRITY. D. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY, COORDINATE AND CONFIRM WITH THE MECHANICAL AND PLUMBING CONTRACTOR THE EXACT LOCATIONS AND FEED REQUIREMENTS OF ALL EQUIPMENT NEEDING AN ELECTRICAL CONNECTION. C. SEE MECHANICAL/PLUMBING DRAWINGS FOR ELECTRICAL REQUIREMENTS OF ALL MECHANICAL/PLUMBING EQUIPMENT, FOR WIRING AND CONTROL DIAGRAMS, AND FOR EXACT LOCATION OF EQUIPMENT. B. PRIOR TO ROUGH-IN AND FINAL CONNECTION, VERIFY ELECTRICAL REQUIREMENTS AND EXACT LOCATION OF EQUIPMENT BEING PROVIDED BY OTHER TRADES. REFERENCE ENTIRE SET OF CONSTRUCTION DOCUMENTS AS WELL AS FINALIZED SHOP DRAWINGS. A. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, ELEVATIONS, AND BUILDING DETAILS. VERIFY LOCATION OF ALL WALL OUTLETS, SWITCHES, ETC., WITH ARCHITECTURAL DRAWINGS AND ACTUAL CONDITIONS. COMMON REQUIREMENTS: I. EXISTING LOW VOLTAGE WIRING WHICH WILL NOT BE MADE OBSOLETE AND WHICH WILL BE DISTURBED DUE TO CONSTRUCTION CHANGES REQUIRED BY THIS CONTRACT SHALL BE RESTORED TO CONDITION, OR POSITION, AS REQUIRED. PROPERLY RE-SECURE CABLE IN CHASES, CRAWL SPACES, TUNNELS, AND CEILING SPACES AS REQUIRED BY NEC. IN SOME CASES IT MAY BE NECESSARY TO ADD SUPPORTING HARDWARE TO ACCOMPLISH THIS REQUIREMENT. H. ALL ELECTRICAL CONNECTIONS REQUIRING AN OUTAGE SHALL BE MADE DURING AN APPROVED TIME LIMIT. CHANGEOVERS SHALL BE AS SHORT A DURATION AS POSSIBLE AND SHALL NOT INTERFERE WITH NORMAL OPERATION OF THE OWNER'S FACILITIES. NOTICE SHALL BE REQUIRED IN ADVANCE OF A SHUTDOWN OF ANY ELECTRICAL CIRCUIT FOR CHANGEOVER, AND SUCH A CHANGEOVER SHALL BE DONE DURING HOURS AS DIRECTED BY OWNER. WORK SHALL BE SCHEDULED SO THAT AT NO TIME WILL ANY EMERGENCY FEEDER, CIRCUIT, OR FIRE ALARM ZONE BE OUT OF SERVICE. PROVIDE NECESSARY TEMPORARY FEEDERS TO ACCOMPLISH THIS REQUIREMENT. G. EXAMINE ARCHITECTURAL, STRUCTURAL, AND MECHANICAL DRAWINGS AND SPECIFICATIONS TO DETERMINE THE SEQUENCE OF CONSTRUCTION THROUGHOUT THE PROJECT, INCLUDING EXISTING, TEMPORARY, REMODELED AND NEW AREAS. F. ALL TEMPORARY AND REMODELING WORK SHALL BE CONSIDERED A PART OF THIS CONTRACT AND NO EXTRA CHARGES WILL BE ALLOWED. THIS SHALL INCLUDE MINOR ITEMS OF MATERIAL OR EQUIPMENT NECESSARY TO MEET THE REQUIREMENTS AND INTENT OF THE PROJECT. E. THE CONTRACTOR SHALL BE HELD FULLY RESPONSIBLE FOR THE PROPER RESTORATION OF ALL EXISTING SURFACES REQUIRED PATCHING, PLASTERING, PAINTING AND/OR OTHER REPAIR DUE TO THE INSTALLATION OF ELECTRICAL WORK UNDER THE TERMS OF THIS SPECIFICATION. CLOSE ALL OPENINGS, REPAIR ALL SURFACES, ETC., AS REQUIRED. THE CONTRACTOR SHALL EMPLOY QUALIFIED AND EXPERIENCED WORKMEN FOR THIS WORK. ALL RESTORATION WORK SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT AND/OR THE OWNER. D. OUTLETS FROM WHICH FIXTURES, SWITCHES, RECEPTACLES, AND/OR OTHER ELECTRICAL DEVICES ARE MOVED AND WHICH ARE NOT REPLACED OR REUSED SHALL BE REMOVED OR, IF IT IS NOT POSSIBLE TO REMOVE, PLACE A BLANK COVER ON THE OUTLET BOX. WHERE OUTLETS, BOXES, ETC., ARE COMPLETELY REMOVED, THE CONTRACTOR SHALL CUT OFF CONDUITS AND REMOVE WIRING. C. EXISTING ELECTRICAL WIRING WHICH WILL NOT BE MADE OBSOLETE AND WHICH WILL BE DISTURBED DUE TO CONSTRUCTION CHANGES REQUIRED BY THIS CONTRACT SHALL BE RESTORED TO OPERATING CONDITION, AS REQUIRED AND/OR DIRECTED. WHERE REQUIRED, SHOWN AND/OR DIRECTED, OUTLETS AND CONDUIT RUNS SHALL BE RELOCATED. IN SOME CASES IT MAY BE NECESSARY TO EXTEND CONDUITS AND PULL IN NEW WIRING OR INSTALL JUNCTION BOXES AND SPLICE IN NEW WIRING OR REPLACE OLD WIRING WITH NEW. B. BRANCH CIRCUITS SHALL BE REUSED WHERE PRACTICAL AND SHALL, IN ADDITION, BE REMODELED AS REQUIRED. THE CONTRACTOR SHALL CONCEAL ALL WORK WHERE POSSIBLE. WHERE EXPOSED WORK IS REQUIRED IN FINISHED AREAS, THE CONTRACTOR SHALL USE WIREMOLD RACEWAY WITH #500 BEING THE MINIMUM SIZE ACCEPTABLE. A. CERTAIN RENOVATION OF ELECTRICAL FACILITIES WILL BE REQUIRED IN THE EXISTING BUILDING. EXISTING CONDUIT RUNS ARE GENERALLY NOT SHOWN, ALTHOUGH A FULL ATTEMPT HAS BEEN MADE TO SHOW SOME EXISTING CONDITIONS, OF WHICH INFORMATION HAS BEEN TAKEN FROM EXISTING RECORD DRAWINGS OF THIS PROJECT. THE DRAWINGS SHOWING LOCATION OF EXISTING EQUIPMENT, OUTLETS, FIXTURES, ETC., IN EXISTING AREAS ARE APPROXIMATE ONLY (FIELD VERIFY). RENOVATION NOTES: H. EXISTING EQUIPMENT NOT IMPLICITLY SHOWN ON THE DRAWINGS IS INTENDED TO BE "EXISTING TO REMAIN UNCHANGED", UNLESS NOTED OTHERWISE. 6. REMOVAL OF FEEDER CONDUIT IF FOUND TO BE UNSALVAGEABLE BY ARCHITECT, ENGINEER OR OWNER'S REPRESENTATIVE. 5. CAPPING OF FEEDER CONDUIT AT 6" ABOVE OR BELOW FLOOR/CEILING AS REQUIRED AND MARKING LOCATION OF POINT OF FEED WITH AN ENGRAVED BRASS TAG. 4. PATCHING OF WALLS, FLOORS AND CEILINGS PER ARCHITECT'S INSTRUCTIONS. 3. REMOVAL OF ALL FITTINGS, SUPPORTS, BRACKETS, ETC. 2. REMOVAL OR RE-CIRCUITING OF ALL BRANCH CIRCUITING. 1. REMOVAL OF FEEDER FROM EQUIPMENT TO POINT OF FEED. G. WORK REQUIRED FOR EXISTING EQUIPMENT NOTED AS "EXISTING TO BE REMOVED" SHALL INCLUDE: F. MAKE AS-BUILTS WITH NEW TYPED DIRECTORIES FOR ALL PANELBOARDS, INDICATING CIRCUIT DESCRIPTION (USED OR SPARE), CIRCUIT BREAKERS AND CIRCUIT LOAD. E. REMOVED OR DAMAGED CONDUIT, WIRE, AND FITTINGS SHALL NOT BE REUSED FOR RELOCATED OR NEW DEVICES. D. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK REQUIRED TO REMOVE/RELOCATE ANY EXISTING ELECTRICAL EQUIPMENT SUCH THAT ELECTRIC SHOCK HAZARDS TO WORKMEN ARE ELIMINATED DURING DEMOLITION AND NEW CONSTRUCTION. C. ELECTRICAL CONTRACTOR TO PROVIDE ALL NECESSARY LABOR, CONDUIT, WIRE, CONNECTIONS, ETC., FOR DEVICES, FIXTURES, ETC., NOTED AS "EXISTING TO REMAIN" SUCH THAT EXISTING CIRCUIT CONTINUITY IS MAINTAINED. B. REMOVE ALL EXISTING WIRING DEVICES, LIGHT FIXTURES, WIRE, CONDUIT, ETC., AS NOTED OR INDICATED WITHIN DEMOLITION AREA. (ALL ITEMS MAY NOT BE SHOWN). REWORK AS NECESSARY CIRCUITING WHICH REQUIRES CONTINUATION THROUGH THE AREA. A. RETURN REMOVED MATERIAL DEEMED SALVAGEABLE BY OWNER'S REPRESENTATIVE. MATERIALS DEEMED NOT SALVAGEABLE SHALL BE REMOVED FROM THE PREMISES. DEMOLITION: GENERAL NOTES A. THE WORK TO BE PERFORMED UNDER THIS DIVISION OF THE SPECIFICATIONS SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, TRANSPORTATION, CONSTRUCTION, FACILITIES, AND INCIDENTALS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL ELECTRICAL WORK AS SHOWN AND INDICATED ON THE CONTRACT DRAWINGS, AND/OR HEREIN SPECIFIED WITH THE INTENT THAT THE INSTALLATION SHALL BE COMPLETE IN EVERY RESPECT, READY FOR USE. COMPLY WITH THE LATEST EDITION IN FORCE OF THE NFPA CODES INCLUDING THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES. WORK INCLUDED FIRE ALARM D. SUBMIT ELECTRONIC COPIES OF OPERATING AND MAINTENANCE MANUAL/RECORD DOCUMENTS. MANUAL/RECORD DOCUMENTS SHALL CONSIST OF MANUFACTURER'S STANDARD PRODUCT DATA, MANUFACTURER'S CURRENT PRINTED OPERATING AND MAINTENANCE INSTRUCTION, LIST OF ORIGINAL SPARE PARTS, LIST OF SUPPLIERS DISTRIBUTING SPARE PARTS, RECOMMENDED QUANTITIES TO BE MAINTAINED IN STORAGE, TEST REPORTS AS REQUIRED BY CODE (IF SYSTEM REQUIRED), APPROVAL DOCUMENTATION OF THE AHJ (IF SYSTEM REQUIRED), PROGRAMING INFORMATION STORED ON A FLASH DRIVE (FIRE ALARM ONLY), PAPER COPIES OF ALL DOCUMENTATION STORED IN THE FIRE ALARM DOCUMENT CABINET (FIRE ALARM ONLY). MANUAL SHALL INCLUDE INFORMATION ON THE FOLLOWING: WIRING DEVICES/COVER PLATES OCCUPANCY/VACANCY SENSORS LIGHTING C. SUBMIT ELECTRONIC COPIES OF OPERATING AND MAINTENANCE MANUAL/RECORD DOCUMENTS. MANUAL/RECORD DOCUMENTS SHALL CONSIST OF MANUFACTURER'S STANDARD PRODUCT DATA, MANUFACTURER'S CURRENT PRINTED OPERATING AND MAINTENANCE INSTRUCTIONS, LIST OF ORIGINAL SPARE PARTS, LIST OF SUPPLIERS DISTRIBUTING SPARE PARTS, RECOMMENDED QUANTITIES TO BE MAINTAINED IN STORAGE AND ALL WARRANTIES. MANUAL SHALL INCLUDE INFORMATION ON THE FOLLOWING: FIRE ALARM B. SUBMIT ELECTRONIC COPIES OF PRODUCT DATA, SHOP DRAWINGS, WIRING DIAGRAMS, LAYOUT DRAWINGS , BATTERY CALCULATIONS PER CODE (IF SYSTEM REQUIRED), AND NICET CERTIFICATE FOR DESIGN TECHNICIAN (IF SYSTEM REQUIRED). LITERATURE SHALL BE MARKED TO INDICATE THE SIZE, TYPE OR MODEL BEING PROPOSED AND ALL ACCESSORIES TO BE PROVIDED: WIRING DEVICES/COVER PLATES OCCUPANCY/VACANCY SENSORS LIGHTING AND LIGHTING CONTROLS A. SUBMIT ELECTRONIC COPIES OF PRODUCT DATA, SHOP DRAWINGS, WIRING DIAGRAMS AND LITERATURE ON SYSTEMS INDICATED BELOW. LITERATURE SHALL BE MARKED TO INDICATE THE SIZE, TYPE OR MODEL BEING PROPOSED AND ALL ACCESSORIES TO BE PROVIDED. SUBMITTALS B. THE ELECTRICAL CONTRACTOR SHALL BE HELD FINANCIALLY RESPONSIBLE FOR ANY AND ALL COSTS OF THE ENGINEER'S TIME REQUIRED TO REVIEW AND RESEARCH NON-SPECIFIED EQUIPMENT SUBMITTED FOR SUBSTITUTION BY THE ELECTRICAL CONTRACTOR. THESE COSTS SHALL BE AUTOMATICALLY INVOICED TO THE CONTRACTOR UNLESS SUCH SUBSTITUTIONS FOLLOW THE GUIDELINES FOR SUBSTITUTION AND ARE WITHIN THE PROPER TIME FRAME AS OUTLINED IN OTHER SECTIONS OF THIS SPECIFICATION. A. "APPROVED EQUAL" INDICATES THE SPECIFYING ENGINEER SHALL APPROVE ALL CONTRACTOR PROPOSED ALTERNATE MATERIAL OR MANUFACTURERS. ENGINEER'S DECISION IS FINAL. GENERAL B. MANUFACTURER'S WARRANTY ON ALL EQUIPMENT SHALL BE FOR A TIME PERIOD OF ONE (1) YEAR FROM SUBSTANTIAL COMPLETION UNLESS NOTED OTHERWISE. A. CONTRACTOR'S WARRANTY ON COMPLETE ELECTRICAL INSTALLATION SHALL BE FOR A TIME PERIOD OF ONE (1) YEAR FROM SUBSTANTIAL COMPLETION. WARRANTY B. COORDINATE INSTALLATION OF SERVICE ENTRANCE THOROUGHLY WITH UTILITY COMPANY. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RELATED TO SERVICE ENTRANCE WORK, INCLUDING ANY CHARGES FROM THE UTILITY COMPANY. A. IN GENERAL, COORDINATE WORK THOROUGHLY WITH OTHER TRADES, OWNER AND UTILITY COMPANIES TO PROVIDE EFFICIENT FLOW OF THE WORK AND TIMELY COMPLETION OF THE CONTRACT. COORDINATION C. "APPROVED EQUAL" INDICATES THE SPECIFYING ENGINEER SHALL APPROVE ALL CONTRACTOR PROPOSED ALTERNATE MATERIAL OR MANUFACTURERS. ENGINEER'S DECISION IS FINAL. B. IDENTIFICATION: LAMINATED PLASTIC LABELS ON ALL EQUIPMENT, SWITCHES, CONTROLS, ETC. A. IN GENERAL ALL MATERIALS SHALL BE: NEW, U.L. LISTED FOR THE SPECIFIC APPLICATION AS SPECIFIED OR AS REQUIRED, AND INSTALLED PER MANUFACTURER'S INSTRUCTIONS. BASIC MATERIALS G. PROVIDE CONDUIT SEALING FITTINGS IN ACCORDANCE WITH NEC AND WHERE INDICATED ON DRAWINGS. LOCATE FITTINGS AT SUITABLE, APPROVED, ACCESSIBLE LOCATIONS AND FILL WITH U.L. LISTED SEALING COMPOUND. INSTALL SEALING FITTINGS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. F. CONDUIT SHALL BE INSTALLED CONCEALED UNLESS NOTED OTHERWISE ON DRAWINGS. E. RGS CONDUIT SHALL BE USED IN OUTDOOR EXPOSED LOCATIONS, INDOOR DAMP OR WET LOCATIONS, HAZARDOUS LOCATIONS, OR WHERE REQUIRED BY NEC AND WHERE NOTED ON DRAWINGS. D. EMT MAY BE USED WHERE PERMITTED BY NEC EXCEPT WHERE OTHER TYPE IS SPECIFIED HEREIN OR NOTED ON DRAWINGS. C. MINIMUM CONDUIT SIZE SHALL BE 3/4". B. RIGID GALVANIZED STEEL (RGS) CONDUIT: COMPLYING WITH ANSI C80.1, THREADED CONDUIT WITH APPROVED FITTINGS, SIZED AS SHOWN ON DRAWINGS OR IF NOT SIZED ON THE DRAWINGS, IN ACCORDANCE WITH NEC AND OTHER APPLICABLE PORTIONS OF THE CONTRACT DOCUMENTS. A. ELECTRICAL METALLIC TUBING (EMT): COMPLYING WITH ANSI C80.3 WITH COMPRESSION TYPE FITTINGS, SIZED AS SHOWN ON DRAWINGS OR IF NOT SIZED ON THE DRAWINGS, IN ACCORDANCE WITH NEC AND OTHER APPLICABLE PORTIONS OF CONTRACT DOCUMENTS. CONDUIT 4. BE U.L. LISTED AND LABELED FOR THEIR APPLICATION. 3. BE OF PROPER SIZE AND SHAPE FOR CONDUITS ENTERING THEM. 2. BE NEMA TYPE 3R OR NEMA TYPE 4 FOR INDOOR DAMP OR WET LOCATIONS AND OUTDOOR LOCATIONS. 1. BE NEMA TYPE 1 FOR INDOOR DRY LOCATIONS. B. ALL PULL/JUNCTION BOXES AND ENCLOSURES SHALL: 4. BE CAST TYPE FOR EXPOSED WORK BELOW 10'-0" AFF. 3. BE U.L. LISTED AND NEC RATED FOR THEIR APPLICATION. 2. BE OF PROPER SIZE AND SHAPE FOR CONDUITS ENTERING THEM. 1. BE STAMPED, ONE PIECE, GALVANIZED STEEL. A. ALL STANDARD INTERIOR OUTLET BOXES SHALL: BOXES E. MC CABLE SHALL NOT BE USED EXCEPT FOR FIXTURE WHIPS. D. ALL CONDUCTORS FOR BRANCH CIRCUITS SHALL BE COPPER. C. ALL CONDUCTORS SIZE #10 AND SMALLER SHALL BE SOLID COPPER. CONDUCTORS SIZE #8 AND LARGER SHALL BE STRANDED. B. ALL CONDUCTORS SHALL BE COLOR CODED WITH WIRE LABELS INSTALLED FOR EASY IDENTIFICATION. A. ALL CONDUCTORS SHALL BE COPPER, 600 VOLT, TYPE THHN/THWN UNLESS OTHERWISE NOTED. MINIMUM WIRE SIZE SHALL BE #12 AWG FOR POWER WIRING AND #14 AWG FOR CONTROL WIRING. WIRE AND CABLES A. ALL CONNECTORS SHALL BE OF MATERIAL COMPATIBLE WITH THE MATERIAL OF THE CONDUCTORS TO PREVENT CORRODING, DIFFERENCES IN COEFFICIENTS OF EXPANSION AND ELECTROLYSIS AS MANUFACTURED BY IDEAL, BURNDY, THOMAS AND BETTS, AND 3-M. WIRE CONNECTIONS AND DEVICES WIRE COLOR CODE FOR 120/208V, 3Ø, 4W PHASE A: BLACK PHASE B: RED PHASE C: BLUE NEUTRAL: WHITE GROUND: GREEN WIRE COLOR CODE FOR 480V PHASE A: BROWN PHASE B: ORANGE PHASE C: YELLOW NEUTRAL: GRAY GROUND: GREEN D. WIRE SHALL BE COLOR CODED IN INDUSTRY STANDARD FORMAT, COLORED CONDUCTOR OR COLORED TAPE WRAPPING. C. RECEPTACLES SHALL HAVE ENGRAVED COVER PLATES IDENTIFYING THE PANEL AND CIRCUIT NUMBER. B. ALL PANELBOARDS SHALL BE PROVIDED WITH A TYPEWRITTEN CIRCUIT DIRECTORY, LAMINATED AND MOUNTED INSIDE THE PANEL COVER. A. ALL PANELBOARDS, SWITCHBOARDS, DISCONNECT DEVICES, CONTROLLERS, ETC., SHALL BE PROVIDED WITH A WHITE NAMEPLATE WITH BLACK ENGRAVED LETTERS MOUNTED IN A VISIBLE LOCATION ON THE DEVICE. PLATE SHALL INDICATE THE DEVICE TAG, THE SOURCE OF POWER AND THE CIRCUIT NUMBER. IDENTIFICATION c. PASS & SEYMOUR/LEGRAND #2097W b. LEVITON #N7899 a. HUBBELL #GFST20 GFCI RECEPTACLE c. PASS & SEYMOUR/LEGRAND #5362 b. LEVITON #5362 a. HUBBELL #HBL 5362 20 AMP, STRAIGHT BLADE, NEMA 5-20R 4. APPROVED PRODUCTS: 3. COVERPLATES SHALL BE HIGH IMPACT, SMOOTH NYLON TYPE; COLOR SHALL MATCH WIRING DEVICE UNLESS NOTED OTHERWISE. 2. SNAP SWITCHES SHALL BE QUIET-TYPE; COMPLYING WITH U.L. STANDARD 20 AND FEDERAL SPECIFICATION W-S-896. 1. RECEPTACLES SHALL BE NEMA 5-20, STRAIGHT BLADE, GROUNDING TYPE, COMPLYING WITH FEDERAL SPECIFICATION WC-596F. A. WIRING DEVICES SHALL BE U.L. LISTED, HEAVY DUTY INDUSTRIAL GRADE TYPE, 1. COMPLYING WITH NEMA STANDARD WD 1. COLOR SHALL BE DETERMINED BY THE DESIGN PROFESSIONAL DURING SHOP DRAWINGS. WIRING DEVICES 1. MATCH EXISTING. D. APPROVED MANUFACTURERS: 1. SYSTEMS SHALL MATCH EXISTING SYSTEM IN BUILDING. B. CEILING MOUNTED SYSTEMS A. LIGHTING SYSTEM CONTROLS ARE DIAGRAMMATIC AND ARE GENERIC. SUCCESSFUL LIGHTING CONTROL SYSTEM VENDOR SHALL THOROUGHLY EXAMINE PLANS AND SHALL PROVIDE CONTRACTOR WITH DETAILED LAYOUT DRAWINGS AND BILL OF MATERIALS TO PROVIDE A COMPLETE AND OPERATIONAL SYSTEM WITHOUT REQUESTS FOR ADDITIONAL MONETARY COMPENSATION FOR "MISSING" COMPONENTS. OCCUPANCY/VACANCY SENSORS F. PROVIDE "BLACK-OUT" TEST OF EMERGENCY LUMINAIRES UPON PROJECT COMPLETION IN THE PRESENCE OF THE AUTHORITY HAVING JURISDICTION. E. CORRECT WIRING DEFICIENCIES AND REPAIR OR REPLACE DAMAGED OR DEFECTIVE PRODUCTS. REPAIR OR REPLACE EXCESSIVELY NOISY BALLASTS AS DETERMINED BY ARCHITECT. D. TEST SELF-POWERED EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND FLUORESCENT EMERGENCY POWER SUPPLY UNITS TO VERIFY PROPER OPERATION UPON LOSS OF NORMAL POWER SUPPLY. C. OPERATE EACH LUMINAIRE AFTER INSTALLATION AND CONNECTION TO VERIFY PROPER OPERATION. B. INSPECT EACH PRODUCT FOR DAMAGE AND DEFECTS. A. SEE SECTION 01 4000 - QUALITY REQUIREMENTS FOR ADDITIONAL REQUIREMENTS. FIELD QUALITY CONTROL A. PERFORM COMPLETE OPERATIONAL TEST OF ELECTRICAL INSTALLATION BEFORE ACCEPTANCE BY OWNER. TEST SHALL BE PERFORMED IN PRESENCE OF OWNER'S REPRESENTATIVE. TESTING B. SEE LUMINAIRE SCHEDULE ON DRAWINGS FOR DESCRIPTION. 2. FURNISHED WITH 6'-0" OF FLEXIBLE CONDUIT PREWIRED (DROP IN ONLY). BE U.L. LISTED IN ACCORDANCE WITH THE NEC. 1. FURNISHED WITH PROPER OUTLET BOXES, HANGERS, HARDWARE, SUPPORTS, CANOPY EXTENSIONS, PLUGS. A. LUMINAIRES SHALL BE: LIGHTING J. SUBMIT A CERTIFICATE OF COMPLETION PER NFPA 72. I. PROVIDE DEMONSTRATION OF THE MODIFIED FIRE ALARM SYSTEM TO THE OWNER. PERFORM ALL THE FUNCTIONS SPECIFIED. H. BEFORE REQUESTING FINAL APPROVAL OF THE INSTALLATION, THE INSTALLING CONTRACTOR SHALL FURNISH A WRITTEN STATEMENT TO THE EFFECT THAT THE SYSTEM HAS BEEN INSTALLED AND TESTED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE APPROPRIATE NFPA REQUIREMENTS. G. FIRE ALARM SYSTEM MODIFICATIONS AND EXPANSION SHALL BE INSTALLED AND FULLY TESTED UNDER THE SUPERVISION OF A MANUFACTURER'S SPECIFICATIONS AND THE APPROPRIATE NFPA REQUIREMENTS. REPORTS OF ALL TESTING DURING INSTALLATION SHALL BE SUBMITTED TO THE OWNER AND ENGINEER UPON REQUEST. F. NEW AUDIBLE/VISUAL ALARM DEVICES SHALL BE 100% COMPATIBLE WITH THE EXISTING FIRE ALARM CONTROL PANEL; SHALL COMPLY WITH ADA REQUIREMENTS; SHALL BE LISTED AND LABELED PER U.L. STANDARD 1971; AND UL 464 15CD TYPE STROBE, UNLESS NOTED OTHERWISE. SURFACE MOUNT DEVICES AT 80" ABOVE FINISHED FLOOR OR AT 6" BELOW CEILING, WHICHEVER IS LOWER. PROVIDE ASSOCIATED BACKBOX. E. NEW VISUAL ALARM DEVICES SHALL BE 100% COMPATIBLE WITH THE EXISTING FIRE ALARM CONTROL PANEL; SHALL COMPLY WITH ADA REQUIREMENTS; SHALL BE LISTED AND LABELED PER U.L. STANDARD 1971; 15CD TYPE STROBE, UNLESS OTHERWISE NOTED. SURFACE MOUNT DEVICES AT 80" ABOVE FINISHED FLOOR OR AT 6" BELOW CEILING WHICHEVER IS LOWER. PROVIDE ASSOCIATED BACKBOX. D. ALL WIRING SHALL BE VERIFIED WITH FIRE ALARM EQUIPMENT SUPPLIER AS TO QUANTITY, SIZE, ROUTING, CONDUIT, JUNCTION BOX REQUIREMENTS, ETC. C. PROVIDE HARDWARE AND PROGRAMMING MODIFICATIONS REQUIRED TO THE EXISTING ALARM CONTROL PANEL AND ASSOCIATED ACCESSORIES TO EXPAND THE EXISTING SYSTEM AS INDICATED ON THE DRAWINGS. ALL MODIFICATIONS SHALL BE COMPLETE BY MANUFACTURER'S AUTHORIZED TECHNICIAN. B. ALL NEW WIRING SHALL BE 100% COMPATIBLE WITH EXISTING FIRE ALARM SYSTEM AND SHALL BE AS DIRECTED BY THE MANUFACTURER OF THE EXISTING FIRE ALARM SYSTEM. A. ALL DEVICES AND EQUIPMENT ADDED TO THE EXISTING FIRE ALARM SYSTEM SHALL BE 100% COMPATIBLE WITH THE EXISTING SYSTEM. ALL NEW DEVICES AND EQUIPMENT SHALL BE U.L. LISTED AND SHALL CONFORM TO NFPA 72. EXISTING FIRE ALARM SYSTEM EMERGENCY POWER SYSTEM OR BALLAST/DRIVER LUMINAIRE TYPE PANEL NAME LUMINAIRE - RECESSED (REFER TO LUMINAIRE SCHEDULE) CONNECTED FOR NIGHT LIGHT USE 1LP-1a NL CIRCUIT NUMBER AND SWITCH LEG (LUMINAIRES ARE CONTROLLED BY LOCAL SWITCH UNLESS DESIGNATION GIVEN) A SPECIAL SYSTEMS HANDICAP DOOR OPERATORS - SEE ARCHITECURALS WITH 3/4" CONDUIT a WALL MOUNTED LUMINAIRE T-1 45 KVA 3Ø 208Y/120VAC # AF # AT # A # A 75 75 C 75 C 75 75 C G ST GROUND FAULT PROTECTED BREAKER SHUNT TRIP BREAKER CURRENT TRANSFORMER POTENTIAL TRANSFORMER # AF DRAWOUT CIRCUIT BREAKER # AT FUSE PANELBOARD 1 Room name 101A PLUMBING EQUIPMENT CALL-OUT: REFER TO THE EQUIPMENT DATA SCHEDULE FOR DETAILS J J M G # A # POLES PANEL ### F J DUPLEX RECEPTACLE (NEMA 5-20R) - MOUNTED 18" AFF GFI GROUND FAULT CIRCUIT INTERRUPTER SS SURGE SUPPRESSOR (ISOLATED GROUND TYPE) WP WEATHERPROOF HG HOSPITAL GRADE TR TAMPER RESISTANT D DEDICATED USB STANDARD DUPLEX WITH 2 USB PORTS FLOOR BOX - SEE SPECS OR KEYED NOTES ON PLAN FOR DETAILS TOGGLE SWITCH - MOUNTED 48" AFF b LOWER CASE LETTER DENOTES LTG. SWITCH GROUP 2 DOUBLE-POLE SINGLE-THROW (DPST) 3 3-WAY 4 4-WAY B PUSHBUTTON D DIMMER (WALL BOX TYPE) K KEY OPERATED M MANUAL MOTOR STARTER P PILOT LIGHT T TIMER TT THERMAL TRIP SWITCH WP WEATHERPROOF OS WALL BOX OCCUPANCY SENSOR OS2 WALL BOX OCCUPANCY SENSOR FOR TWO LEVEL SWITCHING VS WALL BOX VACANCY SENSOR LV LOW VOLTAGE SWITCH TC TEACHER CONTROLS STATION TE TEACHER ENTRY STATION MC MOMENTARY CONTACT SWITCH OS CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR a LOWER CASE LETTER DENOTES LTG. SWITCH GROUP NOTIFICATION APPLIANCE MOUNTED 80" AFF OR 6" FROM CEILING WHICHEVER IS LOWER C CHIME H HORN LF LOW FREQUENCY NOTIFICATION APPLIANCE - STROBE ONLY MOUNTED 80" AFF CANDELA VALUE AS SHOWN MINIMUM NOTIFICATION APPLIANCE WITH STROBE MOUNTED 80" AFF OR 6" FROM CEILING WHICHEVER IS LOWER CANDELA VALUE AS SHOWN MINIMUM C CHIME H HORN LF LOW FREQUENCY NOTIFICATION APPLIANCE (CEILING) C CHIME STROBE H HORN STROBE LF LOW FREQUENCY CANDELA VALUE AS SHOWN MINIMUM CEILING MOUNTED COMBINATION VOICE EVACUATION SPEAKER AND STROBE CANDELA VALUE AS SHOWN MINIMUM COMBINATION VOICE EVACUATION SPEAKER AND STROBE MOUNTED AT 80" AFF CANDELA VALUE AS SHOWN MINIMUM F CO S S a VS CEILING MOUNTED DUAL TECHNOLOGY VACANCY SENSOR a LOWER CASE LETTER DENOTES LTG. SWITCH GROUP RTS REMOTE TEST SWITCH GROUND BAR 100A4G # KVA/KW 480Y/277V, 3Ø, 4W AHU 1 GWH1 1 # C ENCLOSED CIRCUIT BREAKER DATE: DRAWN: REVIEWED: SHEET TITLE: SHEET NUMBER: PROJECT NO.: PROJECT: ISSUE: # DATE: DESCRIPTION: NOT FOR CONSTRUCTION DESIGNED: 4/8/2020 10:32:47 AM E0.1 GENERAL INFORMATION JPG APC 0200100.04 Downtown Transit Center - Restroom Upgrades City of Fort Collins 250 N. MASON ST. FORT COLLINS, CO 04.08.2020 INM 90% CD SYMBOLS LEGEND NOTE: NOT ALL SYMBOLS ARE USED IN CONSTRUCTION DOCUMENTS MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MCP MOTOR CIRCUIT PROTECTOR MDF MAIN DISTRIBUTION FRAME MDP MAIN DISTRIBUTION PANEL MEPFP MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION MGB MASTER GROUND BAR MH MANHOLE MH METAL HALIDE MIN MINIMUM MLO MAIN LUG ONLY MOCP MAXIMUM OVERCURRENT PROTECTION MSB MAIN SWITCHBOARD MTG MOUNTING MTS MANUAL TRANSFER SWITCH MVA MEGAVOLT-AMPERES MW MEGAWATT MWH MEGAWATT-HOURS N NEUTRAL N/A NOT APPLICABLE NC NORMALLY CLOSED NEC NATIONAL ELECTRIC CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NF NONFUSED NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NL NIGHT LIGHT NO NORMALLY OPEN NP NAMEPLATE NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OH OVERHEAD OWN OWNER P POLE PA PUBLIC ADDRESS PB PULL BOX PC PHOTOCELL PC PLUMBING CONTRACTOR PF POWER FACTOR PH PHASE PIR PASSIVE INFRARED PLC PROGRAMMABLE LOGIC CONTROLLER PNL PANEL PR PAIR PRI PRIMARY PT POTENTIAL TRANSFORMER PV PHOTOVOLTAIC PVC POLYVINYL CHLORIDE PWC PRE-WIRED CONTROLS PWR POWER RCPT RECEPTACLE REQD REQUIRED RF RADIO FREQUENCY RM ROOM RMC RIGID METAL CONDUIT RNC RIGID NON-METALLIC CONDUIT (SCH 40) RVAT REDUCED VOLTAGE - AUTOTRANSFORMER SC SHORT CIRCUIT SCC SHORT CIRCUIT CURRENT RATING SDP SUBDISTRIBUTION PANEL SEC SECONDARY SHLD SHIELD(ED) (AS IN CABLE) SHT SHEET SPD SURGE-PROTECTIVE DEVICE SPDT SINGLE POLE DOUBLE THROW SPST SINGLE POLE SINGLE THROW SR SINGLE RECEPTACLE ST SHUNT TRIP SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR TBD TO BE DETERMINED TC TIMECLOCK TCC TEMPERATURE CONTROLS CONTRACTOR TEMP TEMPERATURE TT THERMAL TRIP SWITCH TTB TELEPHONE TERMINAL BOARD TYP TYPICAL U UTILITY UG UNDERGROUND UL UNDERWRITERS LABORATORY UON UNLESS OTHERWISE NOTED UPS UNINTERUPTABLE POWER SUPPLY V VOLTS VA VOLT-AMPERES VAC VOLTS ALTERNATING CURRENT VDC VOLTS DIRECT CURRENT VFD VARIABLE FREQUENCY DRIVE VND VENDOR W WATTS W WIRE WHM WATTHOUR METER WP WEATHERPROOF XFMR TRANSFORMER XP EXPLOSION PROOF %Z IMPEDANCE (E) EXISTING (ALSO COVERED BY TEXT WEIGHT) (F) FUTURE (PART) PARTIAL CIRCUIT (R) RELOCATE A AMPERES AC 6" ABOVE COUNTER ADA AMERICANS WITH DISABILITIES ACT AF AMPERES FRAME AFCI ARC FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AIC AMPERES INTERRUPTION CAPACITY AL ALUMINUM AT AMPERES TRIP ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BMS BUILDING MANAGEMENT SYSTEM C CONDUIT CAM CAMERA CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CCW COUNTER CLOCKWISE CKT CIRCUIT CL CENTER LINE CLG CEILING CO CONDUIT ONLY CRI COLOR RENDERING INDEX CT CURRENT TRANSFORMER CU COPPER CW CLOCKWISE DIA DIAMETER DISC DISCONNECT DIST DISTRIBUTION DPDT DOUBLE POLE DOUBLE THROW DPST DOUBLE POLE SINGLE THROW DR DUPLEX RECEPTACLE DWG DRAWING(S) EC ELECTRICAL CONTRACTOR ELC ELEVATOR CONTRACTOR ELEC ELECTRIC/ELECTRICAL EM EMERGENCY EMT ELECTRICAL METALLIC TUBING EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EXP EXPLOSION PROOF F FUSED FA FIRE ALARM FAA FIRE ALARM ANNUNCIATOR FACP FIRE ALARM CONTROL PANEL FC FOOTCANDLE FLA FULL LOAD AMPERES FMC FLEXIBLE METAL CONDUIT FO FIBER OPTIC FPC FIRE PROTECTION CONTRACTOR FS FUSED SWITCH FSD FIRE/SMOKE DAMPER FT FOOT/FEET FVNR FULL VOLTAGE, NON-REVERSING FVR FULL VOLTAGE, REVERSING G GROUND GC GENERAL CONTRACTOR GEN GENERATOR GF GROUND FAULT GFI/GFCI GROUND FAULT INTERRUPTER GND GROUND/GROUNDING H HORIZONTALLY MOUNTED HH HANDHOLE HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTO HP HORSEPOWER HPS HIGH PRESSURE SODIUM HZ FREQUENCY I/O INPUT/OUTPUT ID INSIDE DIAMETER IDF INTERMEDIATE DISTRIBUTION FRAME IG ISOLATED GROUND IMC INTERMEDIATE METAL CONDUIT ISC SHORT CIRCUIT CURRENT JB JUNCTION BOX K KELVIN (COLOR TEMPERATURE) KCMIL 1000 CIRCULAR MILS KV KILOVOLTS KVA KILVOLT-AMPERES KW KILOWATTS KWH KILOWATT-HOUR LAN LOCAL AREA NETWORK LC LIGHTING CONTACTOR LCP LIGHTING CONTROL PANEL LED LIGHT EMITTING DIODE LF LINEAR FOOT LFMC LIQUID-TIGHT FLEXIBLE METAL CONDUIT LM LUMEN LTG LIGHTING LV LOW VOLTAGE MAN MANUAL MOTOR STARTER WITH OVERLOADS MAX MAXIMUM MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPERES ABBREVIATIONS COORDINATE WITH NEW CONSTRUCTION B. ALL ITEMS INDICATED TO BE DEMOLISHED SHALL BE REMOVED AS TO FULLY ALLOW FOR THE PROPER FURNISHING AND INSTALLATION OF ALL SCHEDULED NEW WORK. THIS SHALL INCLUDE DEMOLITION OF ADJACENT ITEMS, ACCESSORIES, AND APPURTENANCES AS NECESSARY. C. DEMOLITION DRAWINGS ILLUSTRATE MAJOR ITEMS TO BE REMOVED. CONTRACTOR SHALL COORDINATE THESE DRAWINGS WITH NEW WORK DRAWINGS AND SHALL BE RESPONSIBLE FOR OTHER ITEMS REQUIRED TO BE DEMOLISHED TO ACCOMMODATE NEW WORK. D. THE CONTRACTOR IS RESPONSIBLE FOR RETAINING AND RELOCATING ALL SALVAGE AS DESIGNATED BY THE OWNER'S REPRESENTATIVE. E. PROTECT ALL FINISHES TO REMAIN FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION. F. PRIOR TO DEMOLITION, ENSURE THE STABILITY OF ANY WALLS TO REMAIN. G. REMOVE CEILINGS INCLUDING, BUT NOT LIMITED TO, RELATED SUPPORT SYSTEMS, CEILING TILES, LIGHT FIXTURES, GRILLES, DIFFUSERS, EXIST SIGNS, AND OTHER ELECTRICAL OR COMMUNICATION DEVICES. H. DEMOLITION OF FLOOR FINISHES INCLUDES REMOVAL OF ADHESIVES, GROUTING BEDS, RESILIENT BASE, ETC. I. REMOVAL OF EXISTING PLUMBING FIXTURES TO INCLUDE PIPING, WASTE LINES, ETC. LINES ARE TO BE CAPPED AS REQUIRED. SEE PLUMBING DRAWINGS. J. REMOVAL OF EXISTING HVAC TO INCLUDE DUCTWORK, HANGERS, GRILLES, DIFFUSERS, ETC. SEE MECHANICAL DRAWINGS. K. REMOVAL OF EXISTING ELECTRICAL SYSTEMS TO INCLUDE CONDUIT, BOXES, WIRE, CABLE, SUPPORTS, WIRING DEVICES, SAFETY SWITCHES, FIRE ALARM EQUIPMENT, SPEAKERS, TELEPHONE OUTLETS AND LIGHT FIXTURES. SEE ELECTRICAL DRAWINGS. DEMOLITION GENERAL NOTES A. CONTRACTOR TO PROVIDE ALL ADDITIONAL FRAMING NECESSARY FOR ALL OPENINGS AND SUPPLEMENTAL FRAMING ABOVE PARTITIONS. B. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES FOR SYSTEM RELATED PENETRATIONS NOT SHOWN. C. CONTRACTOR SHALL MAINTAIN THE BUILDING IN A WEATHERPROOF CONDITION AT ALL TIMES. D. PROJECTS SHALL REMAIN IN COMPLIANCE WITH ALL ASPECTS OF ALL GOVERNING CODES AND ORDINANCES DURING THE COURSE OF CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, EXITING, FIRE ALARM SYSTEM(S) SMOKE/FIRE DETECTION SYSTEM(S), SPRINKLER SYSTEM(S). E. TEMPORARY BARRICADES AS PERTAINING TO CONTRACTOR'S ACTIVITIES SHALL BE INSTALLED TO PREVENT POSSIBLE INJURY TO PERSONS IN AND AROUND DEMOLITION AND CONSTRUCTION AREAS IN ACCORDANCE WITH OSHA REQUIREMENTS. COORDINATE WITH OWNER. F. ALL AREAS TO BE DEMOLISHED OR DISTURBED BY ANY DEMOLITION ARE TO BE PATCHED AND PAINTED (OR PREPARED FOR OTHER SCHEDULED FINISH). IF PAINTING IS REQUIRED, ENTIRE WALL SHALL RECEIVE PAINT TO AVOID MISMATCH OF COLOR. G. ALL OPENINGS AND VOIDS LEFT BY THE REMOVAL OF EXISTING CONSTRUCTION, EQUIPMENT, PIPING, DUCTS, ETC, SHALL BE PROPERLY PATCHED AND CLOSED OFF TO MAINTAIN PROPER FIRE RATING IN AFFECTED WALL, FLOOR, OR ROOF. PREPARE PATCHED AREAS TO RECEIVE NEW FINISHES AS SCHEDULES (OR MATCH EXISTING FINISHES IF NOT OTHERWISE IDENTIFIED). H. WHEN PATCH OF EXISTING FLOOR IS REQUIRED, SLOPING OR RAMPING IN EXCESS OF CONTRACT TOLERANCES WILL NOT BE ALLOWED (1/8" PER 10 FEET MAXIMUM). I. UPON REMOVAL OF TEMPORARY PARTITIONS, CONTRACTOR IS RESPONSIBLE FOR PATCHING TO MATCH EXISTING ADJACENT CONSTRUCTION. J. AT CONSTRUCTION ACCESS, CONTRACTOR TO PROVIDE LABOR AND MATERIALS TO REPAIR ALL DISTURBED ELEMENTS. K. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO PROVIDE COMPLETE WORKING SYSTEMS FOR ALL NEW ELEMENTS AND TO COORDINATE THEIR WORK WITH ALL OTHER TRADES. L. ALL CONTRACTORS SHALL PROVIDE NEW, UNDAMAGED MATERIALS UNLESS OTHERWISE SPECIFIED. M. STORE MATERIALS IN SUCH A MANNER AS NOT TO OVERSTRESS, OVERLOAD, OR OTHERWISE PUT AN UNSAFE LOAD ON ANY STRUCTURE DURING CONSTRUCTION. N. INSTALL ALL WORK IN ACCORDANCE WITH CURRENT APPLICABLE CODES, PUBLISHED STANDARDS, AND ACCEPTABLE CONSTRUCTION STANDARDS. O. DETAILS ARE GENERALLY TYPICAL AND ARE NOT TO BE CONSTRUED AS LIMITED TO THOSE AREAS SPECIFICALLY INDICATED. REVIEW ANY QUESTIONS OR CONFLICTING INFORMATION WITH THE DESIGN PROFESSIONAL PRIOR TO FABRICATION OR INSTALLATION. P. CONTRACTOR SHALL VERIFY DIMENSIONS IN FIELD PRIOR TO BEGINNING CONSTRUCTION. Q. HINGE SIDE OF DOOR JAMBS TO BE LOCATED 4” FROM NEAREST WALL INTERSECTION UNLESS OTHERWISE NOTED. GENERAL NOTES 1-1/2" DIAMETER GRAB BAR TOILET TISSUE DISPENSER SANITARY NAPKIN DISPOSAL TOILET FIXTURE TOILET FIXTURE TOILET TISSUE DISPENSER 1-1/2" DIAMETER GRAB BAR EXPOSED PLUMBING AT BARRIER FREE LAVATORIES SHALL BE INSULATED. LEVER OPERATING CONTROLLED SOAP DISPENSER NOTE: SINKS IN COUNTERS TO BE MOUNTED WITH RIM NO MORE THAN 2'-10" HIGH AND WITH AT LEAST 2'-3" KNEE CLEARANCE. CLEAR ACCESSIBLE TOILET TYPICAL ACCESSIBLE CLEARANCE AT LAVATORY TYPICAL ACCESSIBLE LAVATORY AND MIRROR 1'-3" 1'-3" 2'-5" MIN 2'-10" MAX 3'-4" MAX 4'-0" MAX 6'-8" A.F.F. 1'-6" 17" - 19" 5'-0" CLEAR 3'-0" 6" 17" - 19" 3'-0" MAX 3'-4" 1'-6" 1'-0" 3'-6" 2'-4" 5'-0" CLEAR MIN 8" MAX 6" MIN 9" 2'-3" MIN 2'-5" MIN 2'-10" MAX 17" MIN TO BOTTOM OF REFLECTIVE SURFACE OF MIRROR 7"-9" PAPER TOWEL DISPENSER/ WASTE RECEPTICLE 4'-0" PAPER TOWEL DISPENSER 4'-0" 2'-0" AT SIDEWALLS AT COUNTER SINKS 1'-6" AT SIDEWALLS AT LAVATORY FINISH FLOOR SEAL GAP @ GYP. BD. TO FLOOR CONDITION BASE - REFER TO FLOOR PLAN KEYNOTES SEE INTERIOR ELEVATIONS FURTHER FINISH INFORMATION 3 5/8" GALVANIZED LIGHT GAUGE METAL STUDS @ 16" O.C. W/ CONTINUOUS STIFFENER CHANNEL 5/8" FIRE RESISTANT GYPSUM BOARD - BOTH SIDES GYPSUMBOARD CEILING @ 8'-6" A.F.F. ACOUSTICAL JOINT SEALANT 1 1A GYPSUM WALLBOARD ONE SIDE ONLY 2'-6" LIGHTGAGE BOXBEAM HEADER 1 2 3 4 5 6 7 8 9 10 A B C D E F G H I J K 1 2 3 4 5 6 7 8 9 10 DATE: DRAWN: REVIEWED: SHEET TITLE: SHEET NUMBER: PROJECT NO.: PROJECT: ISSUE: # DATE: DESCRIPTION: NOT FOR CONSTRUCTION DESIGNED: 3/30/2020 11:07:24 AM A1.1 DEMO AND NEW FLOOR PLAN, NOTES, AND DETAILS JMS JMS 0200100.04 Downtown Transit Center - Restroom Upgrades City of Fort Collins Enter address here 03.30.2020 JMS Preliminary SCALE: 1/4" = 1'-0" 2 FLOOR PLAN #.# KEY PLAN SCALE: 1/4" = 1'-0" 1 DEMOLITION FLOOR PLAN SCALE: 1/4" = 1'-0" 3 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" 4 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" 5 INTERIOR ELEVATION DEMOLITION KEYNOTES (BY DIVISION) DIVISION 06 D6-1 REMOVE EXISTING CASEWORK AND/OR COUNTERTOP DIVISION 08 D8-1 REMOVE EXISTING DOOR FRAME, AND HARDWARE AS REQUIRED FOR NEW WORK DIVISION 09 D9-1 REMOVE EXISTING STUD WALL ASSEMBLY AS REQUIRED FOR NEW WORK D9-2 REMOVE EXISTING CEILING ASSEMBLY AS REQUIRED FOR NEW WORK D9-3 REMOVE EXISTING FLOORING AS REQUIRED FOR NEW WORK TOILET ACCESSORY SCHEDULE MARK DESCRIPTION T1 GRAB BAR (42") T2 GRAB BAR (36") T3 GRAB BAR (18") T4 TOILET TISSUE DISPENSER T5 PAPER TOWEL DISPENSER T6 SOAP DISPENSER - WALL MOUNTED T7 MIRROR UNIT (3'-8" T x 2'-0" W) T8 SEMI-RECESSED PAPER TOWEL DISPENSER / WASTE RECEPTACLE T9 UNDERLAVATORY GUARD SCALE: 3/8" = 1'-0" STANDARD MOUNTING HEIGHTS DOOR SCHEDULE DOOR DOOR FRAME LBL HDWR NO. WIDTH HEIGHT THICK MAT'L FINISH ELEV MAT'L FINISH SET NOTES T/ SLAB 101 3' - 0" 7' - 0" 1 3/4" WD PF F HM PNT 01 102 3' - 0" 7' - 0" 1 3/4" WD PF F HM PNT 01 HARDWARE SET 01 2 HINGES 1 ELECTRIFIED HINGE 1 LOCKSET (PRIVACY) 1 CLOSER 1 KICKPLATE 1 CARD READER SILENCERS KEYNOTES (BY DIVISION) DIVISION 00 #.# DIVISION 09 9-1 TILE FLOOR ASSEMBLY 9-2 GYPSUM BOARD CEILING ASSEMBLY - PAINT (SEMI-GLOSS) 9-3 PAINT GYPSUM BOARD ABOVE WALL TILE (SEMI-GLOSS) 9-4 GYPSUM BOARD AND METAL STUD WALL ASSEMBLY INFILL - MATCH ADJACENT FINISH 9-5 NEW RUBBER BASE TO MATCH EXISTING. PAINT GYPSUMBOARD SCALE: 3/4" = 1'-0" PARTITION TYPES