SD Myers LLC (SDM) Analytical Services is pleased to submit this quotation for your
review and approval. Per our discussion, our pricing will be as follows:
Item No. Description Unit Price Qty. Amount
4054 Power Factor
TC's: 43
27.00 1 27.00
4041 Liquid Screen Test 23.00 2 46.00
TC's: 43,44
4043 K F Dissolved Water 23.00 2 46.00
TC's: 43,44
4000 CriticalPac 210.00 16 3,360.00
TC's: 52,54,56,58,60,62,64,66,68,70,72,77,79,81,83,85
4004 LTCPac 105.00 16 1,680.00
TC's: 53,55,57,59,61,63,65,67,69,71,73,78,80,82,84,86
4066 Filming Cmpds/particles 154.00 16 2,464.00
TC's: 53,55,57,59,61,63,65,67,69,71,73,78,80,82,84,86
4005 RegPac-Single
TC's: 74-76
105.00 3 315.00
TD-300 Health Center - Fleet 20.00 16 320.00
4565
Opt Out- Send Hardcopy Reports
25.00
1
25.00
4500
Inspection & Sampling Up To 1 Day
500.00
1
500.00
4501
Inspection & Sampling Additional Day
200.00
1
200.00
180 South Avenue, Tallmadge, Ohio 44278 USA www.sdmyers.com 1-330-630-7000
Page: 2
Quote Number 10203031
TOTAL: 8,983.00
Quoted prices are valid for sixty (60) days and contingent upon the quoted test quantities. Any
change to the number or type of tests could result in a change in quoted prices.
Note that any syringes being supplied for mail-in testing not returned to SD Myers within 90
days are subject to a non-refundable late fee of $30.00.
If you need more information or have any questions about these or additional tests please do not
hesitate to contact me at (800) 444-9580 ext. 3903 or Brian.Carpenter@sdmyers.com. Upon
approval please confirm via email or fax to (330) 633-8081.
Regards,
Brian Carpenter
Diagnostic & Analytical Coord.
SD Myers LLC
180 South Avenue, Tallmadge, Ohio 44278 USA www.sdmyers.com 1-330-630-7000
Page: 3
Quote Number 10203031
Company Overview
SDM has been in the business of testing liquid filled electrical equipment
since 1965. From that time we have served tens of thousands of customers
and have collected more customer and analytical data than anyone in our
industry. This includes millions of transformer test records on hundreds of
thousands of transformers. Our database continues to grow as we analyze
hundreds of thousands of samples annually to determine reliable life of
electrical equipment. In addition to our analytical services we also offer field
service consulting to help our customers understand their electrical
equipment problems and to understand the type of field services they require.
We also offer a variety of educational seminars and materials through our
Training and Education department (T&E). Our T&E materials and courses are
designed to help individuals better understand their electrical equipment to
prevent premature failures and unexpected power outages. Other services
offered are international engineering services to help with moisture reduction
and PCB removal.
Scope of Work Summary
SDM will provide the following services for the preventative maintenance
of your liquid filled electrical equipment which are further defined in this quote:
1. Scheduling of SDM's Mobile Diagnostic Technician.
2. Perform on-site sampling of liquid filled electrical equipment,
equipment inspection, nameplate and equipment data collection.
3. Safely ship samples to our Tallmadge, Ohio lab facility.
4. Test liquid, perform test result analysis, and provide service
recommendations.
5. Provide Transformer Dashboard website access to view test results,
analysis, recommendations, and reports.**
Scheduling
An SDM representative will contact you to schedule work. The normal
work week for SDM technicians is Monday through Friday. Weekend work
and/or specific dates must be scheduled in advance and may result in
additional charges.
Liquid Filled Electrical Equipment Sampling
SDM will provide a qualified technician, tools, supplies, and approved
containers to obtain representative samples of liquid from specified electrical
equipment. The technician will also perform a visual inspection of the
specified equipment, complete a field report and package sample containers
for shipment. The samples and field reports will be shipped to SDM
laboratory for analysis. You must provide the SDM technician with an
escort competent in the knowledge of environmental and safety regulations
pertaining to your facility, along with clear and safe access to equipment. Your
escort will also be responsible for inspecting all equipment worked on and assuring
that all valves are properly and securely closed and no leaks are present.
SDM technicians reserve the right to decline any portion of work they deem
to be hazardous or unsafe.
180 South Avenue, Tallmadge, Ohio 44278 USA www.sdmyers.com 1-330-630-7000
Page: 4
Quote Number 10203031
Safety
SDM provides an average of 40 hours of training per year to all of our field
technicians including, but not limited to, OSHA 10 hour General Industry
Practices, Hazwoper and NFPA 70E training. This training and proper use of
personal protective equipment prepares technicians to safely enter
substations and collect samples from most energized equipment. To further
ensure safety procedures and proper sampling procedures are adhered to,
SDM performs periodic check rides with all of our technicians.
Insurance
SDM carries various types of insurance to industry standards. If it is
necessary for you to obtain a copy of SDM's certificate of insurance please
let your SDM representative know as soon as possible to avoid any delays in
scheduling.
Waste Disposal
To collect a representative sample it is necessary to flush a volume of fluid
from the sample valve prior to collecting the sample. This fluid is classified as
waste generated by the customer. SDM technicians are not permitted to
remove waste fluid from your site. You are responsible for the proper
disposal of all waste fluids generated on site. You should consult federal and
state agencies to identify applicable regulations for proper disposal.
Sample Shipping Information
When shipping samples domestically to a laboratory, you must abide by all
regulations listed in the Code of Federal Regulations (49CFR). International
shipping must abide by IATA (International Air Transportation Association)
regulations. SDM guarantees its customers that the shipping of samples will
be in accordance with these regulations. This protects you from any spills
and or liabilities that may occur due to improper shipping.
Testing, Analysis, and Recommendations
SDM has the resources and capabilities to perform the testing listed on this
quote. Tests are performed in accordance with the methods listed on page 7
of this quote. Sample test analysis will be evaluated and a report
generated for each piece of electrical equipment tested. Reports may include
equipment nameplate data, additional equipment data, if applicable, visual
inspection data, test results, and test analysis. An Executive Recap Report of
all electrical equipment tested in this quote will also be generated to include a
summary of the equipment information, test result analysis, and service
recommendations. Lab Express results will not contain an Executive Recap
Report or any test analysis.
Rush Analysis
If you request an expedited or rush analysis, additional charges will apply
Contact your SDM representative to discuss additional charges and any
necessary arrangements for expedited or rush turnaround.
180 South Avenue, Tallmadge, Ohio 44278 USA www.sdmyers.com 1-330-630-7000
Page: 5
Quote Number 10203031
Transformer Dashboard
For most purchases, analytical data pertaining to each piece of electrical
equipment tested, including the reports listed above will be available via SDM
Transformer Dashboard at www.transformerdashboard.net. An email notification
will be sent to each individual authorized to view test results immediately after
testing is complete. The notification e-mail will provide further instructions for
accessing test results. OCR results will not be available through Transformer
Dashboard.
Health Center
SDM Health Center combines all test results with a transformer's historical
data to give each transformer a rating - At Risk, Service, Watch, or Satisfactory.
Health center will economize the amount of time you spend interpreting your owwn
test result data and help prioritize the maintenance needs of your transformer
fleet. Health Center subscription levels can be customized to transformers
deemed critical to your output or to include all transformers to better anticipate
upcoming maintenance needs. For more information, plese see:
Maintenance Assessment Report
Optional Maintenance Assessment Reports are available for each piece of oil
filled electrical equipment tested. Maintenance Assessment Reports are a
detailed description of the recommended maintenance (including repairs and
reclaiming) needed on each piece of equipment based on the test results of
the equipment. The Maintenance Assessment Report is a great tool to
present to your supervisors, ISO Personnel, and insurance agents. This
report takes the guesswork out of what service needs to be done on "QU"
(Questionable) and "UN" (Unacceptable) test results. It also gives a clean bill
of health on the "AC" (Acceptable) units. Should you have any further
questions or would like to see an example of the Maintenance Assessment
Report please contact your SDM representative.
Payment
Payment terms are Net thirty (30) from date of invoice with no discounts.
Terms and Conditions
This quotation is subject to the Service Agreement Work Order Type (the
“Agreement”) between the City of Fort Collins and SD Myers Inc. executed
November 19, 2015.SDM Analytical Services Terms and Conditions (Revision #5),
attached.
Page: 6
Quote Number 10203031
Project Acceptance
Thank you for your consideration of this proposal. If you would like to move forward, please sign and
return this completed form via email or fax it to (330) 633-8081. I thank you again for this opportunity
to serve you. If you have any further questions, please call me at (800) 444-9580 ext. 3903.
The undersigned agrees to all the above scope of work as stated and agrees to accept SDM
Analytical Services Terms and Conditions (Revision #5)this work is subject to the terms and
condition of the Agreement.
Fort Collins Light & Power Dept. SD Myers LLC
Signature
Name (print)
P.O. Number
Date
Signature
Brian Carpenter
Name (print)
Diagnostic & Analytical Coord.
Title
Date
Gerry Paul, Purchasing Director
August 14, 2019
Page: 7
MaxLife Analytical Test Packages
ITEM PACKAGE ITEMS INCLUDED IN PACKAGE * RECCOMENDED FOR THIS EQUIPMENT
4000 CRITICAL PAC 4041, 4042, 4043, 4046, 4047, 4050, 4054 Any apparatus critical to your operation
4001 POWER PAC 1 4041, 4042, 4043, 4046,4047, 4054 69-230 kV transformers with forced oil cooling
4002 POWER PAC 2 4041, 4042, 4043, 4047, 4054 69-230 kV transformers
4003 DISTRIBUTION PAC 4041, 4042, 4043 Distribution class apparatus
4004 LTC PAC 4041, 4042, 4043 Load Tap Changers
4005 REG PAC SINGLE 4041, 4042, 4043 Regulators
4006 REG PAC THREE 4041, 4042, 4043, 4047, 4050, 4054 Regulators
4007 REG PAC STEP 4041, 4042, 4043, 4047, 4050, 4054 Regulators
4008 OCB PAC 4041, 4042, 4043 Oil Circuit Breakers
4009 SWITCH PAC 4041, 4042, 4043 Switch Gear
4010 S-FLUID PAC 4041, 4042, 4043 Apparatus filled with special fluids
4012 LTC CRITICAL 4041, 4042, 4043, 4066 Load Tap Changers
4051 SIL PAC 4041, 4042, 4043 Silicone filled transformers
4052 ASK PAC 4041, 4043, 4050 Askarel filled transformers
4058 WEC PAC 4041, 4043 Wecosol filled transformers
4060 SIL PAC PLUS 4041, 4042, 4043, 4050 Silicone filled transformers with furan test
4063 FR3/BIOTEMP PAC 4041, 4042, 4043, 4050, 4054 Apparatus with natural and synthetic ester fluids
4064 FR3 PAC PLUS 4041, 4042, 4043, 4047, 4050, 4054 Apparatus with natural and synthetic ester fluids
* For the description of the item numbers, see the following page.
ITEM ANALYSIS ASTM # IEC # SIGNIFICANCE
4041** Liquid Screen Test ** ** The seven (7) tests indicated with (**) are included in
the SD Myers LLC Liquid Screen Test
4041** Neutralization Number ** D 974 60296 Measures acidic constituents; reveals chemical
change or deterioration
4041** InterfacialTension ** D 971 60296 Detects soluble polar contaminants and products of
deterioration
4041** Dielectric Breakdown Voltage ** D 877 60156 Measures ability of insulating liquid to withstand
electric stress without failure; Indicates presence of
contaminating agents
4067 Dielectric Breakdown Voltage D 1816 Method for use on oil being processed into
apparatus. Should not be used for new oil
4041** Color ** D 1500 60296 Increase in color number indicates deterioration of
insulating oil
4041** Specific Gravity ** D 1298 60296 Influences the heat transfer rates and may determine
suitability for use in specific applications
4041** Visual Examination ** D 1524 May detect unusual color changes or contamination
with particulate matter
4041** Sediment ** D 1524 Notes particles in the sample: none, light, medium or
heavy
4047^ Oxidation Inhibitor Content D 2668 * 60666 * Measures the amount of inhibitor remaining after
oxidation have reduced its concentration
4054^ Liquid Power Factor
(Dissipation Factor)
D 924 60247 Measures dielectric losses in an oil; indicates
presence of contaminates or deterioration products
4043^ Karl Fischer (Water Content) D 1533 60814 High water content may make a dielectric liquid
unsuitable for some electrical applications
4050 Furanic Compounds D 5837 61198 Determines the aging rate of paper insulation and
the type and extent of damage
4042 Gas Content D 3612 60567 The rate of gas generation and changes in
concentration of specific gasses over time may be
used to evaluate the condition of electrical apparatus
4046^ Dissolved Metals (ICP) D 7151 Determines the amount of metals in solution; in
conjunction with other tests is a diagnostic tool for
transformer operation
4044 Polychlorinated Biphenyls (PCB ) D 4059 60997 Measures the amount of PCB's present in oil in order
to handle and /or dispose of in the manner
prescribed by law
4090 Degree of Polymerization D 4243 Measures the remaining life of the paper insulation
4081 Particle Count Distribution D 6786 Provides a general degree of contamination level;
useful in accessing the condition of specific types of
electrical equipment
4066 Particle and Filming
Compounds Analysis
Proprietary
Identifies particles and oxidation compounds
4087 Corrosive Sulfer D 1275 315/86 Test for corrosive sulfur compounds in oil
4089 Flash Point D 92 60034 Indicates the flammability of an oil
4091 Pour Point D 97 3016 Indicates the lowest temperature to which oil may be
cooled without limiting the circulation of the oil
4085 Resistivity D 1169 60247 Measures electrical insulating properties of the liquid
4083 AGE (allyl glycidyl ether) Measures remaining acid scavenger in Askarel units
retrofilled with perchloroethylene
4084 Viscosity D 445 3104 Measures oils resistance to flow
^ Test method(s) performed with modifications to ensure higher accuracy and quality results.
Should you need additional information, please contact us at DL-DASRequest@sdmyers.com.
* For FR3 fluids we use an internal method.