Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CORRESPONDENCE - BID - 8197 SMALL LANDSCAPE & IRRIGATION ANNUAL (5)
Work Order Form Official Purchasing Form Last updated 10/2017 WORK ORDER FORM PURSUANT TO A MASTER AGREEMENT BETWEEN THE CITY OF FORT COLLINS AND KORBY WORK ORDER NUMBER: PROJECT TITLE: Beattie POC & Pump Renovation ORIGINAL BID/RFP NUMBER & NAME: 8197 SMALL LANDSCAPE & IRRIGATION ANNUAL MASTER AGREEMENT EFFECTIVE DATE: March 1, 2016 WORK ORDER COMMENCEMENT DATE: 10/4/2018 WORK ORDER COMPLETION DATE: 5/1/2018 MAXIMUM FEE: (time and reimbursable direct costs): 28,997.06 PROJECT DESCRIPTION/SCOPE OF SERVICES: Renovation of irrigation point of connection and install of pump purchased by Parks. See drawings. Service Provider agrees to perform the services identified above and on the attached forms in accordance with the terms and conditions contained herein and in the Master Agreement between the parties. In the event of a conflict between or ambiguity in the terms of the Master Agreement and this Work Order (including the attached forms) the Master Agreement shall control. The attached forms consisting of ( ) page(s) are hereby accepted and incorporated herein, by this reference, and Notice to Proceed is hereby given after all parties have signed this document. SERVICE PROVIDER: Date: Steve Korby, Korby ACCEPTANCE: Date: Jill Wuertz, Project Manager REVIEWED: Date: Elliot Dale, Buyer or Senior Buyer ACCEPTANCE: Date: Gerry Paul, Purchasing Director (if greater than $60,000) DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 10/4/2018 11:09:43 AM PDT 10/9/2018 10:33:56 AM MDT 10/11/2018 3:51:42 PM PDT Landscape Quote 9/26/2018 # 20864 Bill To CITY OF FORT COLLINS ATTN: JILL WUERTZ P.O. BOX 580 FT COLLINS, CO 80521 Ship To Beattie School Pumphouse/Hydrometer/POC Renovation P.O. Number Terms Net 30 Project Date 10/26/2018 Rep KK Project Approval Signature: ________________________________________________________________ __________________ Total Sales Tax (7.4%) www.korbylandscape.com Bus: 970.232.1127 Fax:970.568.7635 KORBY LANDSCAPE, LLC 2406 E COUNTY RD 60 WELLINGTON, CO 80549 Email: info@korbylandscape.com Description Qty Cost Total Beattie Pumphouse Estimate Electrical Services ( Installing New Pump and VFD) 1 11,475.00 11,475.00 LABOR CHARGES FOR DIGGING POC, BACKFLOW, IRRIGATION TIE IN AND BACKFLOW PAD 108 50.00 5,400.00 LABOR FOR LANDSCAPE INDUSTRY CERTIFIED TECHNICIAN TO INSTALL BACKFLOW, POC TIE IN AND PLUMBING TO PUMP 62 56.00097 3,472.06 Hydrometer 2" Photo Diode 1 2,200.00 2,200.00 2" Febco 825YA Backflow 1 1,650.00 1,650.00 Guard Shack Enclosure Aluminum 1 1,250.00 1,250.00 Copper Parts for POC, Backflow & Pump Tie In and Outlet. ( Piping, Valves, Blow out, Iso Valves, Bell Housing) 1 3,150.00 3,150.00 Labor Charge for Landscape Supervisor for VFD Wiring and Startup supervision 8 50.00 400.00 $28,997.06 $0.00 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Q: In the electrical plans I didn't see an electrical disconnect for the pump could you verifiy this for me? A: The equipment is within and in site of the panel. The breaker in the panel is the disconnect. Mike Gust mgust@gustengineering.com Q: I didn't see any up stream or down stream Iso valves for the pump house I assume you would want one between the POC and Backflow and possible one down stream where the pump ties into the park irrigation. A: The PPS shop drawing shows butterfly valves on the upstream side of the pump which is per plan. The backflow preventer will typically have valves on each side of backflow (complete isolation). Jason Klausner, P.E., CLIA | Project Engineer jason@aquaengineering.com DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 DATE SHEET NO. DESIGNED BY DRAWN BY CHECKED BY REVISIONS 1/XX/2018 IR1.0 HYDROMETER RENOVATION BEATTIE ELEM. CITY OF FORT COLLINS FORT COLLINS, CO JHK JHK CBK - - - - NOT FOR CONSTRUCTION PRELIMINARY DESIGN NOT FOR CONSTRUCTION PRELIMINARY DESIGN NOT FOR CONSTRUCTION PROJECT LOCATION MAP IMAGE BY GOOGLE EARTH N.T.S. BEATTIE ELEM. GENERAL DESCRIPTION GENERAL NOTES NOTES AND DEMOLITION PLAN 1 BEATTIE ELEMENTARY IRRIGATION DEMOLITION PLAN N.T.S. DEMOLITION ITEMS: 1. DISCONNECT PIPING FROM EXISTING WATER METER. ABANDON BELOW GRADE PIPING IN PLACE. 2. REMOVE ALL EXISTING IRRIGATION PLUMBING WITHIN EXISTING BOOSTER PUMP BUILDING. RETURN SALVAGEABLE MATERIALS TO THE OWNER'S REPRESENTATIVE. DISPOSE OF UNWANTED ITEMS OFFSITE. 3. DISCONNECT EXISTING PUMP FROM 7.5 HP SINGLE PHASE MOTOR. RETURN MOTOR TO OWNER'S REPRESENTATIVE. KEEP PUMP FOR INSTALLATION ONTO NEW MOTOR. 4. DISCONNECT AND REMOVE EXISTING BREAKER BOX AND CONDUIT AND CONDUCTORS TO EXISTING BOOSTER PUMP. RETURN SALVAGEABLE MATERIALS TO THE OWNER'S REPRESENTATIVE. DISPOSE OF UNWANTED ITMES OFFSITE. ENSURE ELECTRICAL POWER IS DEENERGIZED PRIOR TO WORK AND ALL ELECTRICAL WORK CONDUCTED PER NEC CODES. REFER TO ELECTRICAL PLANS. 5. COORDINATE ALL DEMOLITION ACTIVITIES WITH THE OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 DATE SHEET NO. DESIGNED BY DRAWN BY CHECKED BY REVISIONS 1/XX/2018 IR2.0 HYDROMETER RENOVATION BEATTIE ELEM. CITY OF FORT COLLINS FORT COLLINS, CO JHK JHK CBK - - - - NOT FOR CONSTRUCTION PRELIMINARY DESIGN NOT FOR CONSTRUCTION PRELIMINARY DESIGN NOT FOR CONSTRUCTION RENOVATION PLAN 1 BEATTIE ELEMENTARY IRRIGATION RENOVATION PLAN N.T.S. EQUIPMENT LIST EXISTING CONCRETE BUILDING. NOTE: BUILDING INTERIOR HEIGHT IS 85-INCHES. EXISTING BREAKER BOX AND ELECTRICAL PANEL. REFER TO ELECTRICAL PLANS. EXISTING WATER METER (MANHOLE LID) 2-INCH TYPE K COPPER PIPE AND FITTINGS - CONNECT TO EXISTING METER AND ROUTE TO NEW BACKFLOW PREVENTER 2-INCH REDUCED PRESSURE BACKFLOW PREVENTER (FEBCO 825YA OR EQUAL) INSTALLED WITHIN ALUMINUM ENCLOSURE (STRONGBOX SBBC OR EQUAL, SIZED AS NECESSARY) 2-INCH TYPE K COPPER PIPE FROM BACKFLOW PREVENTER TO PUMP. CORE DRILL THROUGH WALL AND ROUTE PIPE THROUGH WALL. ALL EXTERIOR COPPER PIPE PAINTED BLACK TO DETER THEFT. SEAL PENETRATION WITH HYDRAULIC CEMENT. 2-INCH BRASS BALL VALVE 2-INCH BRASS OR COPPER UNION EXISTING PUMP - REFER TO DEMOLITION PLAN. INSTALL NECESSARY FITTINGS TO COMPLETE PIPE CONNECTION (INLET). INSTALL NEW MECHANICAL SEAL AND GASKETS. NEW 7.5 HP, 3500 RPM, 230/60/3 PH MOTOR (213JM FRAME). SECURE TO CONCRETE FLOOR USING RUBBER VIBRATION DAMPENERS. REFER TO SPECIFICATIONS. 2-INCH TYPE K COPPER PIPE FROM PUMP DISCHARGE. INSTALL NECESSARY FITTINGS FOR CONNECTION TO PUMP DISCHARGE. PRESSURE TRANSDUCER, PRESSURE GAUGE, AND HARDWARE HYDROMETER - WIRE TO EXISTING IRRIGATION CONTROLLER PER MANUFACTURER'S GUIDELINES. INSTALL WIRING WITHIN 1-INCH RIGID METAL CONDUIT ROUTED ALONG WALLS AS NECESSARY TO IRRIGATION CONTROLLER. MAKE ALL NECESSARY CONNECTIONS. 2-INCH TYPE K COPPER PIPE AND FITTINGS FROM PUMP TO PENETRATION THROUGH WALL. CORE DRILL THROUGH WALL AND ROUTE PIPE THROUGH WALL. ALL EXTERIOR COPPER PIPE PAINTED BLACK TO DETER THEFT. SEAL PENETRATION WITH HYDRAULIC CEMENT. FLOW P1 PCP LP11 MT LP11 - 1,3 3 # 8 & 1 # 10 FLEX CONNECTION GRD. IN 3/4" AT MOTOR MT EP ELECTRICAL LEGEND ELECTRICAL EQUIPMENT PANELBOARD OR SWITCHBOARD SAFETY SWITCH FRACTIONAL HP MOTOR ELECTRICAL FIXTURES DUPLEX RECEPTACLE LIGHTING FIXTURES WALL LIGHT SURFACE MOUNTED FLUORESCENT MECHANICAL EQUIPMENT LIGHTING DEVICES SINGLE POLE, SNAP SWITCH S1 (c) S1 = FIXTURE TYPE, c = 120 VOLT WALL SWITCH DESIGNATION S PUMP WIRING WIRING IN CONDUIT, GROUND WIRE IS LINE WITH HOOK SYMBOL, HOT WIRE IS LONG LINE, NEUTRAL IS SHORT LINE. NUMBER OF WIRES AS SHOWN. WIRE SHALL BE #12 MINIMUM AND CONDUIT SHALL BE 1/2" MINIMUM UNLESS AS NOTED ON THE CIRCUIT SCHEDULE(S). LP12-1 ARROW(S) INDICATE HOME RUN(S) WITH PANEL AND CIRCUIT NUMBER(S) INDICATED NOTE: EC SHALL COMPLY WITH NEC110.22a "EACH DISCONNECTING MEANS SHALL BE LEGIBLY MARKED TO INDICATE ITS PURPOSE UNLESS LOCATED AND ARRANGED SO THE PURPOSE IS EVIDENT. THE MARKING SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED." AND 408.4A, "CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION. EVERY CIRCUIT AND CIRCUIT MODIFICATIONS SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT AND SPECIFIC PURPOSE OR USE. ETC." EC SHALL MEET ALL REQUIREMENTS OF THESE ENTIRE SECTIONS. SCHEDULES SHOWN ON THESE PLANS ARE SHORT HAND DESIGNATIONS FOR THE DESIGN AND ARE ONLY TO BE USED FOR CONSTRUCTION. FINAL SCHEDULES SHALL MEET THE REQUIREMENTS OF THE TWO CODE SECTIONS INDICATED IN THIS NOTE. MAIN SERVICE PANEL NEUTRAL BUSS GROUND BUSS BOND NEUTRAL BUSS TO GROUND BUSS GROUND ROD UFER GROUND TO BAR IN FOUNDATION # 6 # 4 # 6 TO BUILDING STEEL # 6 TO BUILDING WATER PIPING REGROUND NEW PANEL WITH MINIMUM AS SHOWN HERE. PERFORMANCE DESIGN FLOW RATE: 100 GPM INTAKE PRESSURE: 70 PSI BOOST PRESSURE: 30 PSI DISCHARGE PRESSURE: 100 PSI ELECTRICAL INPUT VOLTAGE: 240 VOLTAGE/PHASE/Hz VERIFIED BY: PHASE: 1 Hz: 60 x PUMP AND MOTOR FUNCTION QTY HP PUMP TYPE / MOTOR ENCLOSURE RATING MAIN/DUTY 1 5 100 GPM @ 75' TDH END-SUCTION CENTRIFUGAL / ODP PIPING AND SKID PIPING: STEEL A53 SKID: STEEL A36 COATING REQUIREMENT: STANDARD/NON-POTABLE SKID/ WETTED SURFACES / PIPING: PPS BEIGE APPROVED BY: 90% DATE: Vertical Multistage pumps require that intake water be free of suspended solids. Failure to adequately pre-screen can result in severe pump damage. BEATTIE ES HYDROMETER RENOVATION FINAL SUBMITTAL PERFORMANCE SYSTEM SUMMARY CB#C1C005X00100-030XXXX241INS-2 NON-POTABLE QT: 14777 6515 Business Way Boise, ID 83716 www.gopps.us 208-323-5300 STATION ORIENTATION & FLOW VERIFIED BY: X:__________________________________________________________ DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Table of Contents 1 Station Overview 1.1 Station Drawing 1.2 Powder Coating 2 Control Panel Components 2.1 PLC & Components 2.1.1 PLC/Touchscreen 2.1.2 PLC Power Supply 2.2 Motor Starting Components 2.2.1 Variable Frequency Drive 2.3 Overcurrent & Short-circuit Protection 2.3.1 Mini Circuit Breakers 2.3.2 Thermal Magnetic Breaker 2.4 Voltage Management 2.4.1 Transformer 2.4.2 Surge Protection 2.5 Pilot Devices 2.5.1 Potentiometer 2.5.2 HOA Switch 2.6 Electrical Enclosure 2.6.1 Electrical Enclosure 2.6.2 Filter Fan 2.6.3 Exhaust Filter 3 Sensors, Switches, & Gauges 3.1 Pressure Transmitter 3.2 Pressure Gauges 3.3 Flow Switch 4 Pump and Motor Data 4.1 Duty Pump Data 5 Valves 5.1 Butterfly Valves 5.2 Silent Check Valves 5.3 Air Release Valves 6 Miscellaneous 6.1 Pressure Tank DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Industrial Control Panels Industrial control panels. Copyright © 2009 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2009 Underwriters Laboratories Inc.®" NITW.E210861 Industrial Control Panels Page Bottom See General Information for Industrial Control Panels PRECISION PUMPING SYSTEMS E210861 6515 BUSINESS WAY BOISE, ID 83716 USA Last Updated on 2009-05-01 Questions? Notice of Disclaimer Page Top NITW.E210861 - Industrial Control Panels Page 1 of 1 Section 1.3 UL Panel Certification DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Packaged Pumping Systems Packaged pumping systems, Designated Titan series Cat. Nos. T - Turbine series, followed by additional letter and/or numbers; S - Submersible series, followed by additional letter and/or numbers; CB - Series, followed by additional letters and/or numbers; VMS - Series, followed by additional letter and/or numbers; V - Series, followed by additional letter and/or numbers. Copyright © 2009 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2009 Underwriters Laboratories Inc.®" QCZJ.E327721 Packaged Pumping Systems Page Bottom See General Information for Packaged Pumping Systems PRECISION PUMPING SYSTEMS E327721 6515 BUSINESS WAY BOISE, ID 83716 USA Last Updated on 2009-05-29 Questions? Notice of Disclaimer Page Top QCZJ.E327721 - Packaged Pumping Systems Page 1 of 1 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=Q... 6/11/2009 Section 1.4 UL Pump Station Certification DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Purdy Enterprises, Inc. Precision Pumping Systems 6515 Business Way, Boise, Idaho 83716 USA Quality Management System ISO 9001:2015 Manufacture of pumping systems, pump control panels, and remote monitoring and control systems. Certificate No.: CERT-0107103 Original Certification Date: March 29, 2018 File No.: 1694007 Certification Effective Date: March 29, 2018 Issue Date: April 2, 2018 Certificate Expiry Date: March 28, 2021 ________________________________________________________________________________ ISO 9001 Registered by: QMI-SAI Canada Limited (SAI Global), 20 Carlson Court, Suite 200, Toronto, Ontario M9W 7K6 Canada. This registration is subject to the SAI Global Terms and Conditions for Certification. While all due care and skill was exercised in carrying out this assessment, SAI Global accepts responsibility only for proven negligence. This certificate remains the property of SAI Global and must be returned to them upon request. To verify that this certificate is current, please refer to the SAI Global On-Line Certification Register: www.qmi-saiglobal.com/qmi_companies/ This is to certify that operates a which complies with the requirements of for the following scope of certification CERTIFICATE OF REGISTRATION Nicole Grantham General Manager SAI Global Certification Services DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 1 Station Overview DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Model # Design Flow Rate: Minimum Power: GPM @ Volt / HP/Pump DESIGN SPECIFICATIONS Duty Pump Details: GPM @ PSI Boost Phase TDH CB#C1C005X00100-030XXXX241INS-2 240 5 100 100 100 75 1 2 3 9 10 6 Front View 10 1" Blowout 11 5 4 49.0 38.5 10 1 7 Plan View 10 8 9 NEC Panel Clearance See Local Codes 2" Discharge 2" Suction 12 Concrete Pad (By others) Optional HDPE Drop Pipes (CUT-TO-LENGTH) ITEM NO. DESCRIPTION Size QTY. 1 Control Panel 30x20x10 1 2 GAUGE PRESSURE, 0-160PSI, 2-1/2'' BOTTOM PORT 2-1/2" 1 3 GAUGE PRESSURE, 0-200PSI, 2-1/2'' BOTTOM PORT 2-1/2" 1 4 Motor, 3600 RPM 5 HP 1 5 Pressure Tank 2 Gal 1 6 Pump, Centrifugal 3BF 1 7 Skid 48"x33" 1 8 SWITCH, FLOW, 1/2'' NPT 1/2" 1 9 TRANSDUCER, 0-200 PSI, 4-20mA, 1/4'' MALE NPT 1/4" 1 10 VALVE, 2'' GROOVED BUTTERFLY VALVE, NITRILE RUBBER COVERED DISC, LEVER OPERATED 2" 2 11 VALVE, 2'', WAFER CHECK, VALMATIC 2" 1 12 VALVE, 3/4'' AIR RELIEF, VALMATIC 3/4" 1 www.cardinalpaint.com Southern California Powder Coating Corporate Headquarters Manufacturing 1329 Potrero Avenue tel 626.937-6767 South El Monte, CA 91733 tel 626.444.9274 fax 626.444.0382 Arizona Colorado Missouri Pennsylvania Washington State tel 602.437.2401 tel 303.286.1876 tel 314.878.3010 tel 814.728.0721 tel 425.483.5665 Northern California Minnesota North Carolina Texas Hong Kong tel 408.452.8522 tel 952.469.6021 tel 336.882.9493 tel 214.333.9801 tel 852.2410.8200 IMPORTANT: Warranty and Disclaimer – The performance characteristics of these products vary according to the product application, operating conditions, materials applied to or use. Since these factors can affect results, we strongly recommend that you make your own tests to determine your satisfaction whether the product is of acceptable quality, has not been affected by storage or transportation and is suitable for your particular purpose under your own operating conditions prior to using any product in full scale production. Seller warrants the products to be free from defects in materials and workmanship. SUCH WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. No representative of ours has authority to waive or change this provision, which applies to all sales of these products. TECHNICAL DATA SHEET LS #: CURED FILM PROPERTIES 1.5 to 3.0 mils 140 in.lbs. 140 in.lbs. 2H 4B 100% ALL TESTS WERE PERFORMED AT A FILM THICKNESS OF: TEST DIRECT IMPACT(INCH LBS.): INDIRECT IMPACT(INCH LBS.): PENCIL HARDNESS: CROSS HATCH ADHESION: FLEXIBILITY(CONICAL MANDREL): D2794 D2794 D3363 D3359B D1737/D522 METHOD RANGE POLYESTER TGIC POWDER COATING 0DWWH)LQLVK BEIGE POWDER PROPERTIES CURE SCHEDULE: SPECIFIC GRAVITY: SHELF LIFE: (METAL TEMPERATURE) 25 - 50 MICRONS AVERAGE STORE BELOW 80 DEGREES F, IN COOL DRY ENVIRONMENT MINIMUM OF 1 YEAR PARTICLE SIZE: STORAGE; COVERAGE: 58.9 SQ.FT./LB. @ 2 MILS (100% EFFICIENCY) CHEMICAL AND CORROSION EXPOSURE TESTS CHEMICAL RESISTANCE: OVERBAKE RESISTANCE: Good to excellent resistance to most solvents, oils, acids, and alkalies. Sl ight yellowing is evident, especially in white and pastel colors. All tests were performed on 24 gauge Bonderite 1000 panels. APPLICATION This product was designed to be applied by electrostatic spray, on steel, galvanized steel, or aluminum. 2 Control Panel Components DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Programmable Logic Controller (PLC) and Components 2.1 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Human/Machine Interfaces MagelisTM SCU Small HMI controllers Catalog March 2015 Section 2.1.1 Combination PLC-Touchscreen DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Selection guide HMI controllers MagelisTM SCU Small HMI controllers, MagelisTM XBTGC HMI controllers, MagelisTM XBTGT, XBTGK Standard Advanced panels + control function Applications Display of text messages, graphic objects and mimics, control and configuration of data Display of text messages, graphic objects and mimics, control and configuration of data IEC 1131-2 control function IEC 1131-2 control function Terminal type Small HMI controllers HMI controllers Touch screen Standard Advanced panels + control function Standard Advanced panels with keypad + control For control of simple machine For control of simple process function + + Display Type Color TFT LCD Color TFT LCD (320 x 240 pixels) Backlit color TFT LCD (320 x 240 pixels to 1024 x 708 pixels) (1) Monochrome STN LCD or color TFT LCD (320 x 240 pixels or 640 x 480 pixels) (1) Capacity 3 .5" (65 K colors) 5 .7" (65 K colors) 3 .5" (65 K colors) 5 .7" (65 K colors) 5 .7" (65 K colors) 5 .7" (color) 7 .5", 10 .4", 12 .1" or 15" (color) (1) 5 .7" (monochrome or color) or 10 .4" (color) (1) Data entry Via touch screen Via touch screen Via keypad and/or touch screen (configurable) and/or by industrial pointer Static function keys – – 10 or 12 (1) Dynamic function keys – – 14 or 18 (1) Service keys – – 8 Alphanumeric keys – – 12 Memory capacity Application 128 MB Flash EPROM 16 MB Flash EPROM 16 MB Flash EPROM or 32 MB Flash EPROM (1) Expansion – – By 128 MB to 4 GB CF card (1) Functions Maximum number of pages and maximum number of instructions Limited by internal Flash EPROM memory capacity Limited by internal Flash EPROM memory capacity Limited by internal Flash EPROM memory capacity or CF card memory capacity Variables per page Unlimited (8000 variables max .) Unlimited (8000 variables max .) Programmed logic 5 languages according to IEC 1131-2 (LD, ST, FBD, SFC, IL) 5 languages according to IEC 1131-2 (LD, ST, FBD, SFC, IL) Counting/positioning 2 x 100 kHz high speed counter inputs/2 x 50 kHz pulse train outputs 4 x 100 kHz high speed counter inputs/4 x 65 kHz pulse train outputs – Control (PID) Yes Yes Representation of variables Alphanumeric, bitmap, bargraph, gauge, tank, tank level indicator, curves, polygon, button, light Alphanumeric, bitmap, bargraph, gauge, tank, tank level indicator, curves, polygon, button, light Recipes 32 groups of 64 recipes comprising 1024 ingredients max . 32 groups of 64 recipes comprising 1024 ingredients max . Curves Yes, with log Yes, with log Alarm logs Yes Yes Real-time clock Built-in Built-in I/O Integrated v 14 x 24 V c digital inputs v 2 high speed counter (HSC) inputs v 8 digital relay outputs v 2 pulse train source transistor outputs v 6 x 24 V c digital inputs v 2 high speed counter (HSC) inputs v 6 digital relay outputs v 2 pulse train source transistor outputs v 2 x 13-bit analog inputs (Voltage/current) v 2 x 16-bit analogue temperature inputs (TC/PT100-1000) v 2 x 12-bit analog outputs (Voltage/current) v 16 x 24 V c digital inputs v 16 sink or source transistor outputs (1) – I/O modular expansion – 3 Modicon TM2 I/O modules max . – 9 Description (continued) HMI controllers Magelis SCU Small HMI controllers Magelis SCU Small HMI controllers for control of simple processes Description Magelis HMISCUpB5 Small HMI controllers Front panel Magelis SCU Small HMI controllers for control of simple processes have the following on the front panel: 1 A 3 .5" touch screen for displaying mimics (color TFT LCD) or 2 A 5 .7" touch screen for displaying mimics (color TFT LCD) Upper rear panel The upper rear panel has the following: 3 Four removable terminal blocks for 8 digital inputs including 2 fast HSC inputs (100 KHz 1 channel or 50 kHz 2 channel), 6 digital relay outputs, 2 transistor source outputs (PTO/PWM 50 kHz or 20 kHz pulse train if HSC used), 2 analog inputs (voltage, current), 2 temperature inputs (Thermocouple, PT100, PT1000) and 2 analog outputs (voltage, current) Lower rear panel The lower rear panel has the following: 4 A USB mini-B device connector for application transfer (on left-hand side of panel) 5 A removable screw terminal block for 24 V c power supply 6 A 9-way SUB-D connector for CANopen link, fitted with an LED for signalling power supply and system operation status 7 An RJ45 connector for Ethernet TCP/IP, 10BASE-T/100BASE-TX link 8 A type A USB master connector for: v Connection of a peripheral device v Connection of a USB memory stick v Application transfer 9 An RJ45 male connector for RS 232C or RS 485 serial link connection to PLCs (COM1) Fixing system Magelis HMI SCU Small HMI controllers consist of a front module (comprising the screen) and a rear module (comprising the CPU plus terminals and connectors) . The two modules are fixed together via a hole measuring 22 mm in diameter. The fixing system contains the following elements: 10 A fixing nut 11 A seal 12 An anti-rotation tee (can be used as an option) 13 A release mechanism: Simply press to separate the two modules once they have been fixed together This system is included with the complete products (see page 11) . Note: The 2 modules can also be mounted separately: Using a remote connection cable enables the rear module and the front module to be separated and the Controller module mounted on DIN rail (see page 11). 3 3 5 7 6 9 8 5 7 6 9 8 3 11 References HMI controllers Magelis SCU Small HMI controllers HMISCU6p5 HMISCU8p5 Magelis HMISCUpA5 Small HMI controllers for control of simple machines (1) Complete products 24 V c (Screen module + Controller module) Type of screen No. of ports Application memory capacity Compact Flash memory Integrated I/O No. of Ethernet ports Reference Weight kg/lb 3.5" QVGA color TFT 2 USB 1 COM1 1 CANopen 128 MB No 16 digital I/ 10 digital O 1 HMISCU6A5 0 .512/ 1.129 5.7" QVGA color TFT 2 USB 1 COM1 1 CANopen 128 MB No 16 digital I/ 10 digital O 1 HMISCU8A5 0 .764/ 1.684 Magelis HMISCUpB5 Small HMI controllers for control of simple processes (1) Type of screen No. of ports Application memory capacity Compact Flash memory Integrated I/O No. of Ethernet ports Reference Weight kg/lb Complete products 24 V c (Screen module + Controller module) 3.5" QVGA color TFT 2 USB 1 COM1 1 CANopen 128 MB No 8 digital I/8 digital O 4 analog I/ Extended Product Type: Product ID: EAN: Catalog Description: Long Description: EAN: Minimum Order Quantity: Customs Tariff Number: Product Net Width: Product Net Height: Product Net Depth: Product Net Weight: Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 1 Units: Function: Number of Phases: Input Voltage (Uin): Output Voltage (Uout): Output Current: Output Power: General Information CPE 24/1.25 1SVR427031R0000 4016779656870 CPE 24/1.25 Power supply In:100240VAC Out: 24VDC/1.25A The CPE 24/1.25 is a power supply from the CPE range. The primary switch mode power supply offers a wide range input of 85264 V AC and 90375 V DC, rated input voltage is 100240 V AC. The rated output power is 30 W, rated output current is 1.25 A at an output voltage of 24 V DC. The output voltage is adjustable within a range of 24 to 28 V DC. The power supply provides a U/I output characteristic and allows parallel operation to enable redundancy. A further feature is the signalling output (transistor) for output voltage OK. A redundancy unit is available as accessory. Categories Products » Low Voltage Products and Systems » Control Products » Power Supplies Ordering 4016779656870 1 piece 85044090 Dimensions 40.5 mm 90 mm 114 mm 0.27 kg Container Information 132 mm 154 mm 58 mm 0.34 kg 1 piece Technical Switch mode power supply 1 85 ... 264 V AC 90 ... 375 V DC 24 V DC 1.25 A RoHS Status: CCC Certificate: cUL Certificate: cUR Certificate: Declaration of Conformity CE: EAC Certificate: GOST Certificate: RoHS Information: UL Certificate: UR Certificate: eClass: Enummer: ETIM 4.0: ETIM 5.0: Object Classification Code: UNSPSC: Following EU Directive 2002/95/EC August 18, 2005 and amendment Certificates and Declarations (Document Number) CCC_2008010907282731 cUL508_E174460 cUR60950_E196145 cUR1310_E313203 cUR_ANSI_E317914 1SAD9385030113 EAC_RU_CDE.ME77.B.01651 GOST_POCC_CN.AB76.B00924 1SAA9810234402 UL508_E174460 UR60950_E196145 UR1310_E313203 UR_ANSI_E317914 Classifications 7.0 27049002 5218701 EC002540 DCpower supply EC002540 DCpower supply T 39121100 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Motor Control Components DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 F800 SERIES Inverters us.MitsubishiElectric.com/fa/en POCKET REFERENCE GUIDE Section 2.2.1 Variable Frequency Drive DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 F820 Selection Chart Model Number AMPS For Duty Horsepower For Duty (NEC) Frame Size Weight (lbs) SLD LD SLD LD FR-F820-00046-3-N6 4.6 4.2 1 1 A 6 FR-F820-00077-3-N6 7.7 7 2 2 B 6 FR-F820-00105-3-N6 10.5 9.6 3 3 C 9 FR-F820-00167-3-N6 16.7 15.2 5 5 9 FR-F820-00250-3-N6 25 23 7.5 7.5 9 FR-F820-00340-3-N6 34 31 10 10 D 17 FR-F820-00490-3-N6 49 45 20 15 17 FR-F820-00630-3-N6 63 58 20 20 E 20 FR-F820-00770-3-N6 77 70.5 25 25 F 37 FR-F820-00930-3-N6 93 85 30 30 37 FR-F820-01250-3-N6 125 114 40 40 37 FR-F820-01540-3-60 154 140 60 50 G 48 FR-F820-01870-3-60 187 170 60 60 H 92 FR-F820-02330-3-60 233 212 75 75 92 FR-F820-03160-3-60 316 288 125 100 K 119 FR-F820-03800-3-60 380 294 150 125 L 163 FR-F820-04750-3-60 475 432 150 150 163 FR-HEL DC Link Chokes (supplied separately) Drives in shaded area above MUST be used together with a DC Link Choke. Model Number LD SLD FR-F820-03160-3-60 FR-HEL-75K FR-HEL-75K FR-F820-03800-3-60 FR-HEL-90K FR-HEL-110K FR-F820-04750-3-60 FR-HEL-110K FR-HEL-110K Overload Rating 60s 3s Ambient Temp. SLD 110% 120% 40°C LD 120% 150% 50°C Key to Duty Codes Important Note: Drives in shaded area MUST be used together with FR-HEL DC Link Choke (supplied separately). Weights do not include separate DC Link chokes. DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Over Current and Short-circuit Protection 2.3 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 System pro M compact® DIN Rail components for low voltage installation Technical catalogue - Edition 2012 Section 2.3.1 Mini Circuit Breakers DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 2 2/2 ABB Series S 200 S 200 M S 200 P S 200 S S 200 U S 200 UP S 200 UDC SN 201 L SN 201 SN 201 M S 280 Characteristics B,C,D, K,Z B,C,D, K,Z B,C,D, K,Z B,C,D, K,Z B,C,D, K,Z B,C K,Z K,Z K,Z K,Z K, Z B,C B,C,D B,C B,C Rated current [A] 0.5 ≤ In ≤ 63 0.5 ≤ In ≤ 63 0.2 ≤ In ≤ 25 32 ≤ In ≤ 40 50 ≤ In ≤ 63 6 ≤ In ≤ 20 0.2 ≤ In ≤ 25 32 ≤ In ≤ 40 50 ≤ In ≤ 63 0.2 ≤ In ≤ 25 1 ≤ In ≤ 63 2 ≤ In ≤ 40 2 2/14 ABB Technical details ............................ pag. 11/2 Overall dimensions ........................ pag. 13/2 System pro M compact® S 200-C C S 200 C characteristic Function: protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. Applications: residential, commercial and industrial. Standard: IEC/EN 60898, IEC/EN 60947-2 Icn=6 kA Number Rated Order Bbn Price Price Weight Pack of poles current details 4016779 1 piece group 1 piece unit In A Type code Order code EAN kg pc. 1 0.5 S 201-C 0.5 2CDS 251 001 R0984 52329 5 0.125 10 1 S 201-C 1 2CDS 251 001 R0014 52331 8 0.125 10 1.6 S 201-C 1.6 2CDS 251 001 R0974 52330 1 0.125 10 2 S 201-C 2 2CDS 251 001 R0024 52332 5 0.125 10 3 S 201-C 3 2CDS 251 001 R0034 52333 2 0.125 10 4 S 201-C 4 2CDS 251 001 R0044 52334 9 0.125 10 6 S 201-C 6 2CDS 251 001 R0064 46400 0 0.125 10 8 S 201-C 8 2CDS 251 001 R0084 46410 9 0.125 10 10 S 201-C 10 2CDS 251 001 R0104 46420 8 0.125 10 13 S 201-C 13 2CDS 251 001 R0134 46430 7 0.125 10 16 S 201-C 16 2CDS 251 001 R0164 46440 6 0.125 10 20 � S 201-C 20 2CDS 251 001 R0204 46450 5 0.125 10 25 S 201-C 25 2CDS 251 001 R0254 46460 4 0.125 10 32 � S 201-C 32 2CDS 251 001 R0324 46470 3 0.125 10 40 � S 201-C 40 2CDS 251 001 R0404 46480 2 0.125 10 50 S 201-C 50 2CDS 251 001 R0504 55100 7 0.125 10 63 S 201-C 63 2CDS 251 001 R0634 55101 4 0.125 10 2 0.5 S 202-C 0.5 2CDS 252 001 R0984 52335 6 0.250 5 1 S 202-C 1 2CDS 252 001 R0014 52336 3 0.250 5 1.6 S 202-C 1.6 2CDS 252 001 R0974 52337 0 0.250 5 2 S 202-C 2 2CDS 252 001 R0024 52338 7 0.250 5 3 S 202-C 3 2CDS 252 001 R0034 52339 4 0.250 5 4 S 202-C 4 2CDS 252 001 R0044 52340 0 0.250 5 6 S 202-C 6 2CDS 252 001 R0064 46550 2 0.250 5 8 S 202-C 8 2CDS 252 001 R0084 46560 1 0.250 5 10 S 202-C 10 2CDS 252 001 R0104 46570 0 0.250 5 13 S 202-C 13 2CDS 252 001 R0134 46580 9 0.250 5 16 S 202-C 16 2CDS 252 001 R0164 46590 8 0.250 5 20 S 202-C 20 2CDS 252 001 R0204 46600 4 0.250 5 25 S 202-C 25 2CDS 252 001 R0254 46610 3 0.250 5 32 S 202-C 32 2CDS 252 001 R0324 46620 2 0.250 5 40 S 202-C 40 2CDS 252 001 R0404 46630 1 0.250 5 50 S 202-C 50 2CDS 252 001 R0504 55104 5 0.250 5 63 S 202-C 63 2CDS 252 001 R0634 55105 2 0.250 5 3 0.5 S 203-C 0.5 2CDS 253 001 R0984 52341 7 0.375 1 1 S 203-C 1 2CDS 253 001 R0014 52342 4 0.375 1 1.6 S 203-C 1.6 2CDS 253 001 R0974 52343 1 0.375 1 2 S 203-C 2 2CDS 253 001 R0024 52344 8 0.375 1 3 S 203-C 3 2CDS 253 001 R0034 52345 5 0.375 1 4 S 203-C 4 2CDS 253 001 R0044 52346 2 0.375 1 6 S 203-C 6 2CDS 253 001 R0064 46750 6 0.375 1 8 S 203-C 8 2CDS 253 001 R0084 46760 5 0.375 1 10 S 203-C 10 2CDS 253 001 R0104 46780 3 0.375 1 13 S 203-C 13 2CDS 253 001 R0134 46790 2 0.375 1 16 S 203-C 16 2CDS 253 001 R0164 46800 8 0.375 1 SACE Tmax XT UL/CSA New low voltage molded case circuit breakers up to 250A for UL 489 and CSA C22.2 Standards Technical catalog - Preliminary Section 2.3.2 Thermal Magnetic Breaker DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 7 7/8 1SXU200095C0201 | ABB catalog XT1 125A TMF - Fixed (F) - 3 poles - Front terminals (F) - UL/CSA Thermal magnetic trip unit Int Rtng (480V) N 25kA Part number S 35kA Part number H 65kA Part number Type In I3 TMF 15 500 XT1NU3015AFF000XXX XT1SU3015AFF000XXX XT1HU3015AFF000XXX 20 500 XT1NU3020AFF000XXX XT1SU3020AFF000XXX XT1HU3020AFF000XXX 25 500 XT1NU3025AFF000XXX XT1SU3025AFF000XXX XT1HU3025AFF000XXX 30 500 XT1NU3030AFF000XXX XT1SU3030AFF000XXX XT1HU3030AFF000XXX 35 500 XT1NU3035AFF000XXX XT1SU3035AFF000XXX XT1HU3035AFF000XXX 40 500 XT1NU3040AFF000XXX XT1SU3040AFF000XXX XT1HU3040AFF000XXX 45 500 XT1NU3045AFF000XXX XT1SU3045AFF000XXX XT1HU3045AFF000XXX 50 500 XT1NU3050AFF000XXX XT1SU3050AFF000XXX XT1HU3050AFF000XXX 60 600 XT1NU3060AFF000XXX XT1SU3060AFF000XXX XT1HU3060AFF000XXX 70 700 XT1NU3070AFF000XXX XT1SU3070AFF000XXX XT1HU3070AFF000XXX 80 800 XT1NU3080AFF000XXX XT1SU3080AFF000XXX XT1HU3080AFF000XXX 90 900 XT1NU3090AFF000XXX XT1SU3090AFF000XXX XT1HU3090AFF000XXX 100 1000 XT1NU3100AFF000XXX XT1SU3100AFF000XXX XT1HU3100AFF000XXX 110 1100 XT1NU3110AFF000XXX XT1SU3110AFF000XXX XT1HU3110AFF000XXX 125 1250 XT1NU3125AFF000XXX XT1SU3125AFF000XXX XT1HU3125AFF000XXX Ordering codes for XT1 UL/CSA Circuit breakers XT1 125A TMF - Fixed (F) - 4 poles - Front terminals (F) - UL/CSA Thermal magnetic trip unit Int Rtng (480V) N 25kA Part number S 35kA Part number H 65kA Part number Type In I3 TMF 15 500 XT1NU4015AFF000XXX XT1SU4015AFF000XXX XT1HU4015AFF000XXX 20 500 XT1NU4020AFF000XXX XT1SU4020AFF000XXX XT1HU4020AFF000XXX 25 500 XT1NU4025AFF000XXX XT1SU4025AFF000XXX XT1HU4025AFF000XXX 30 500 XT1NU4030AFF000XXX XT1SU4030AFF000XXX XT1HU4030AFF000XXX 35 500 XT1NU4035AFF000XXX XT1SU4035AFF000XXX XT1HU4035AFF000XXX 40 500 XT1NU4040AFF000XXX XT1SU4040AFF000XXX XT1HU4040AFF000XXX 45 500 XT1NU4045AFF000XXX XT1SU4045AFF000XXX XT1HU4045AFF000XXX 50 500 XT1NU4050AFF000XXX XT1SU4050AFF000XXX XT1HU4050AFF000XXX 60 600 XT1NU4060AFF000XXX XT1SU4060AFF000XXX XT1HU4060AFF000XXX 70 700 XT1NU4070AFF000XXX XT1SU4070AFF000XXX XT1HU4070AFF000XXX 80 800 XT1NU4080AFF000XXX XT1SU4080AFF000XXX XT1HU4080AFF000XXX 90 900 XT1NU4090AFF000XXX XT1SU4090AFF000XXX XT1HU4090AFF000XXX 100 1000 XT1NU4100AFF000XXX XT1SU4100AFF000XXX XT1HU4100AFF000XXX 110 1100 XT1NU4110AFF000XXX XT1SU4110AFF000XXX XT1HU4110AFF000XXX 125 1250 XT1NU4125AFF000XXX XT1SU4125AFF000XXX XT1HU4125AFF000XXX Voltage Management 2.4 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Transformers Low Voltage Products & Systems 13.5 ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0201 13 Transformers Primary voltage — 460/230/208V, 480/240V, 440/220/200V Secondary voltage — 115/24V 2, 120/25V, 110/23V Use Class CC fuse Primary voltage — 460/230/208V, 480/240V, 440/220/200V Secondary voltage — 115V, 120V, 110V Use Class CC fuse 1 Primary & secondary fuse block provided as standard (750VA unit, only). 2 Whenever both secondary voltages are to be used at the same time, remove the secondary fuse clip and use a separate mounted 2 pole fuse block. Discount schedule AT [OI] Top View Side View C B D A E Top View Side View C B D A E Top View Side View C B D A E Dimensions A B C D E Mounting slots VA Rating Catalog number Output Amps 24/115 in mm in mm in mm in mm in mm in mm 45 X4045SF1 1.90 / 0.39 41/2 115 3 76 31/8 80 27/8 72 21/2 64 3/16 x 7/16 5 x 12 50 X4050PSF1 2.08 / 0.44 41/2 115 3 76 4 102 27/8 72 21/2 64 3/16 x 7/16 5 x 12 75 X4075PSF1 3.13 / 0.65 41/2 114 33/8 86 4 3/8 110 23/4 71 23/4 71 3/16 x 7/16 5 x 12 100 X4100PSF1 4.17 / 0.87 41/2 115 33/4 95 45/8 118 3 76 31/8 80 3/16 x 7/16 5 x 12 150 X4150PSF1 6.25 / 1.30 5 128 33/4 95 45/8 118 31/8 81 31/8 80 3/16 x 7/16 5 x 12 200 X4200PSF1 8.33 / 1.74 43/8 111 41/2 114 51/4 134 33/4 76 33/4 95 3/16 x 7/16 5 x 12 250 X4250PSF1 10.42 / 2.17 43/4 120 41/2 114 51/4 134 33/4 76 33/4 95 3/16 x 7/16 5 x 12 300 X4300PSF1 12.50 / 2.61 61/8 155 51/4 133 6 151 37/8 98 43/8 111 5/16 x 11/16 8 x 27 350 X4350PSF1 14.58 / 3.04 61/8 155 51/4 133 6 151 37/8 98 43/8 111 5/16 x 11/16 8 x 27 500 X4500PSF1 20.84 / 4.35 71/8 181 51/4 133 51/8 131 5.37 136 43/8 111 5/16 x 11/16 8 x 27 Dimensions Mounting slots A B C D E VA Rating Catalog Number Output Amps in mm in mm in mm in mm in mm in mm 750 X4750PS1 6.52 75/8 193 51/4 133 6 151 53/4 146 43/8 111 5/16 x 11/16 8 x 27 1000 X41K1 8.70 71/8 181 63/8 162 53/8 137 41/2 114 55/16 135 5/16 x 11/16 8 x 17 1500 X41.5K1 13.04 71/2 191 63/4 171 511/16 144 47/16 113 61/16 154 9/32 x 9/16 7 x 14 Transformers 13.8 Low Voltage Products & Systems 1SXU000023C0201 ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 13 Technical data UL Overcurrent protection Primary & secondary Overcurrent protection on both the primary and secondary sides of transformers are specified in UL508 and the National Electrical Code. The maximum acceptable ratings are shown below. Due to the high inrush currents present when a transformer is initially energized, it is recommended that the primary fuse be time delay, to prevent nuisance trips during startup. Maximum acceptable rating of primary overcurrent protection 115 6/10 1-1/4 1-8/10 2-1/2 3-1/2 5 5 6-1/4 7-1/2 10 15 (1) (2) (3-2/10) (4) (6-1/4) (8) 120 6/10 1-1/4 1-8/10 2-1/4 3-1/2 5 5 6-1/4 7 10 15 (1) (2) (3) (4) (6-1/4) (8) 200 3/10 3/4 1-1/8 1-1/2 2-1/4 3 3-1/2 4-1/2 5 6-1/4 9 (6/10) (1-1/4) (1-8/10) (2-1/2) (3-1/2) (5) (6-1/4) (7-1/2) (8) 208 3/10 6/10 1 1-4/10 2 2-8/10 3-1/2 4 5 6 9 (6/10) (1-1/8) (1-8/10) (2-1/4) (3-1/2) (4-1/2) (6) (7) (8) 220 3/10 6/10 1 1-1/4 2 2-1/2 3-2/10 4 4-1/2 5-6/10 8 (1/2) (1-1/8) (1-6/10) (2-1/4) (3-2/10) (4-1/2) (5-6/10) (6-1/4) (7-1/2) 230 3/10 6/10 8/10 1-1/4 1-8/10 2-1/2 3-2/10 3-1/2 4-1/2 5 8 (1/2) (1) (1-6/10) (2) (3-2/10) (4) (5) (6-1/4) (7-1/2) 240 3/10 6/10 8/10 1-1/4 1-8/10 2-1/4 3 3-1/2 4 5 7-1/2 (1/2) (1) (1-1/2) (2) (3) (4) (5) (6-1/4) (7) 277 1/4 1/2 8/10 1 1-6/10 2 2-1/2 3-2/10 3-1/2 5 6-1/4 (4/10) (8/10) (1-1/4) (1-8/10) (2-1/2) (3-1/2) (4-1/2) (5) (6-1/4) (9) 380 3/16 3/10 1/2 3/4 1-1/8 1-1/2 1-8/10 2-1/4 2-1/2 3-1/2 5-6/10 (3/10) (6/10) (8/10) (1-1/4) (1-8/10) (2-1/2) (3-2/10) (3-1/2) (4-1/2) (6-1/4) (9) 400 3/16 3/10 1/2 3/4 1-1/8 1-1/2 1-8/10 2-1/4 2-1/2 3-1/2 5-6/10 (3/10) (6/10) (8/10) (1-1/4) (1-8/10) (2-1/2) (3) (3-1/2) (4) (6-1/4) (9) 415 15/100 3/10 1/2 6/10 1 1-4/10 1-8/10 2 2-1/2 3-1/2 5 (3/10) (6/10) (8/10) (1-1/8) (1-8/10) (2-1/4) (3) (3-1/2) (4) (6) (9) 440 15/100 3/10 1/2 6/10 1 1-1/4 1-6/10 2 2-1/4 3-2/10 5 (1/4) (1/2) (8/10) (1-1/8) (1-6/10) (2-1/4) (2-8/10) (3-2/10) (3-1/2) (5-6/10) (8) 460 15/100 3/10 4/10 6/10 8/10 1-1/4 1-6/10 1-8/10 2-1/4 3-2/10 4-1/2 (1/4) (1/2) (8/10) (1) (1-6/10) (2) (2-1/2) (3-2/10) (3-1/2) (5) (8) 480 15/100 3/10 4/10 6/10 8/10 1-1/4 1-1/2 1-8/10 2 3 4-1/2 (1/4) (1/2) (3/4) (1) (1-1/2) (2) (2-1/2) (3) (3-1/2) (5) (7-1/2) 550 1/8 1/4 4/10 1/2 8/10 1 1-1/4 1-6/10 1-8/10 2-1/2 4 (2/10) (4/10) (6/10) (8/10) (1-1/4) (1-8/10) (2-1/4) (2-1/2) (3) (4-1/2) (6-1/4) 575 1/8 1/4 3/10 1/2 3/4 1 1-1/4 1-1/2 1-8/10 2-1/2 3-1/2 (2/10) (4/10) (6/10) (8/10) (1-1/4) (1-6/10) (2) (2-1/2) (3) (4) (6-1/4) 600 DITEK’s D50 industrial surge protectors are designed to provide protection to AC power systems in the most demanding environments. The D50 incorporates individually fused components for maximum performance and protection. Available in a wide range of voltage configurations, the compact D50 is an excellent choice for electrical panel protection. 50kA/ĭ, 25kA/Mode Surge Protective Device General Product Specifications D50 Series D50 Product Features • Suitable for use on branch panels and small disconnects • Compact size enables close mounting to the protected panel to minimize wire length and maximize performance • 50,000 Amp peak surge current capacity ensures long service life • Available in 8 voltage configurations • Diagnostic LED indicates system power and SPD function • Complies with ANSI/IEEE C62.41 and C62.45 Category B and C3 standards • Ten year limited warranty Specifications Agency Approvals: UL 1449, 3rd Edition, cUL IEEE Location Category: Category B and C3 Protector Type: SPD Type 1 (US), Type 2 (Canada) Peak Surge Current: 50kA/Phase, 25kA/Mode Short Circuit Current Rating: 100,000A Protection Modes: See Chart Temperature Range: -40° – 140°F (-40° – 60°C) Maximum Humidity: 95% non-condensing Operating Frequency: 40Hz – 400Hz Housing: NEMA 4X Dimensions: 3.5”H x 3.5”W x 2.4”D (89mm x 89mm x 61mm) Connection: ½” NPT conduit, watertight fittings Weight: 1.2lb. (.5kg) Options: Flush Mount Kit, D50-FMK Dimensions: 5.0” x 5.0” Plate (127mm x 127mm) Document: SPS-100073-001 Rev 2 09-11 ©2010 DITEK Corp. Specification Subject to Change Industrial Surge Protection Section 2.4.2 Surge Protection DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 50kA/ĭ, 25kA/Mode Surge Protective Device General Product Specifications D50 Series D50 Surge Protection Technical Specifications 347/600VAC Three ĭ 420/840V 10KA 1500V 2500V 1500V 2500V Wye D50-347/6003Y D50-2401 240VAC SINGLE ĭ 320V 10KA 1200V 1200V 2000V N/A D50-240HW 550V 320V 320V/640V 150V/320V 150V/300V 150V/300V MCOV D50-2403D 240VAC Three ĭ Delta 10kA N/A 1200V N/A 2000V 1800V 2000V 1000V HL-G 1500V 1000V 1000V L-G N/A 1200V 600V 600V 600V N-G 4000V 2000V 1200V HL-L 1500V 1200V 1200V L-N L-L N/A 1200V 600V/ HL 1200V 600V 600V UL 1449, 3rd Edition Voltage Protection Rating (VPR) 10kA 10kA 10kA 20kA 20kA UL 3rd Ed. In Rating D50-4803D 480VAC Three ĭ Delta 277/480VAC Three ĭ Wye D50-277/4803Y D50-220/3803Y Pilot Devices 2.5 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 1SFC151004C0201 | Pilot Devices 27 Operator: Potentiometer Description Type Order Code Package Quantity Weight Kg Complete Potentiometers Black knob with integrated position indication and marking in white With Resistor 5 kohm Black Plastic Bezel MT-105B 1SFA 611 410 R1056 1 0.040 Chrome Metal Bezel MT-305B 1SFA 611 410 R3056 1 0.048 With Resistor 10 kohm Black Plastic Bezel MT-110B 1SFA 611 410 R1106 1 0.040 Chrome Metal Bezel MT-310B 1SFA 611 410 R3106 1 0.048 With Resistor 50 kohm Black Plastic Bezel MT-150B 1SFA 611 410 R1506 1 0.040 Chrome Metal Bezel MT-350B 1SFA 611 410 R3506 1 0.048 Knob without Resistor Black knob with integrated position indication and marking in white. For shaft diameter 6 -6.35 mm. Min. shaft length 20 mm. Black Plastic Bezel KT-100B 1SFA 616 410 R1006 10 0.034 Chrome Metal Bezel KT-300B 1SFA 616 410 R3006 10 0.042 Legend Plates Aluminum Symbol: see fig. (29.6 x 44.5 mm) - SK 615 562-87 10 0.002 Scale: 0-10 (48.5 x 44.5 mm) - SK 615 562-88 10 0.002 Scale: 0-50 (48.5 x 44.5 mm) - 1SFA 611 930 R1252 10 0.002 Potentiometers Potentiometer Operator: Buzzer Description Type Order Code Package Quantity Weight Kg Buzzers Black. Frequency: Approx. 2400 Hz. Loudness: Min 80 dB (A)/10 cm Rated Current: < 8 mA. Service Life:>5000 h Suitable for both 50 and 60 Hz networks Supply Voltage Tone Type 24 V AC/DC Continuous KB1-4010 1SFA 616 401 R4010 1x10 0.020 115 V AC/DC Continuous KB1-4030 1SFA 616 401 R4030 1x10 0.020 230 V AC Continuous KB1-4040 1SFA 616 401 R4040 1x10 0.020 24 V AC/DC Pulsating KB1-4110 1SFA 616 401 R4110 1x10 0.020 115 V AC/DC Pulsating KB1-4130 1SFA 616 401 R4130 1x10 0.020 230 V AC Pulsating KB1-4140 1SFA 616 401 R4140 1x10 0.020 Buzzers Buzzer Legend Plates Modular Range Section 2.5.1 Speed Potentiometer DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 1SFC151004C0201 | Pilot Devices 21 Selector Switches three-position, non-illuminated Operator: Three-position Selector Switch Description Type Order Code Package Quantity Weight Kg Short handle Maintained l Red M3SS1-10R 1SFA 611 210 R1001 1x10 0.015 l Black M3SS1-10B 1SFA 611 210 R1006 1x10 0.015 l Grey M3SS1-10U 1SFA 611 210 R1007 1x10 0.015 Momentary, spring return from A to B and from C to B l Red M3SS2-10R 1SFA 611 211 R1001 1x10 0.015 l Black M3SS2-10B 1SFA 611 211 R1006 1x10 0.015 l Grey M3SS2-10U 1SFA 611 211 R1007 1x10 0.015 Momentary, spring return from C to B l Red M3SS3-10R 1SFA 611 212 R1001 1x10 0.015 l Black M3SS3-10B 1SFA 611 212 R1006 1x10 0.015 l Grey M3SS3-10U 1SFA 611 212 R1007 1x10 0.015 Momentary, spring return from A to B l Red M3SS7-10R 1SFA 611 216 R1001 1x10 0.015 l Black M3SS7-10B 1SFA 611 216 R1006 1x10 0.015 l Grey M3SS7-10U 1SFA 611 216 R1007 1x10 0.015 Long handle Maintained l Red M3SS4-10R 1SFA 611 213 R1001 1x10 0.018 l Black M3SS4-10B 1SFA 611 213 R1006 1x10 0.018 l Grey M3SS4-10U 1SFA 611 213 R1007 1x10 0.018 Momentary, spring return from A to B and from C to B l Red M3SS5-10R 1SFA 611 214 R1001 1x10 0.018 l Black M3SS5-10B 1SFA 611 214 R1006 1x10 0.018 l Grey M3SS5-10U 1SFA 611 214 R1007 1x10 0.018 Momentary, spring return from C to B l Red M3SS6-10R 1SFA 611 215 R1001 1x10 0.018 l Black M3SS6-10B 1SFA 611 215 R1006 1x10 0.018 l Grey M3SS6-10U 1SFA 611 215 R1007 1x10 0.018 Momentary, spring return from A to B l Red M3SS8-10R 1SFA 611 217 R1001 1x10 0.018 l Black M3SS8-10B 1SFA 611 217 R1006 1x10 0.018 l Grey M3SS8-10U 1SFA 611 217 R1007 1x10 0.018 Contacts actuated Left block Right block Handle position Center block Handle position Left block Right block Contact Blocks and Holder see the fold-out page at the end of the catalog Selector Switch, short handle Selector Switch, long handle How to order: Alt.1 • Operator + Holder + Contact Block(s) 34 Pilot Devices | 1SFC151004C0201 Accessories for Modular Range Contact Blocks and Holders Description Type Order Code Package Quantity Weight Kg Holders Holders for three positions MCBH-00 1SFA 611 605 R1100 1x10 0.006 Holders for five positions* MCBH5-00 1SFA 611 601 R1100 1x10 0.008 * Note: Double Contact Blocks are required on side positions Single Contact Blocks for front mounting 1 NO MCB-10 1SFA 611 610 R1001 1x10 0.013 1 NO MCB-10 1SFA 611 610 H1001 100 0.013 1 NC MCB-01 1SFA 611 610 R1010 1x10 0.013 1 NC MCB-01 1SFA 611 610 H1010 100 0.013 1 NO with gold plated contacts MCB-10G 1SFA 611 610 R1101 1x10 0.013 1 NC with gold plated contacts MCB-01G 1SFA 611 610 R1110 1x10 0.013 Micro Switch Blocks 1 NO MCBL-10 1SFA 611 612 R1010 1x10 0.010 1 NC MCBL-01 1SFA 611 612 R1001 1x10 0.010 Double Contact Block for front mounting 2 NO MCB-20 1SFA 611 610 R1002 1x10 0.026 2 NC MCB-02 1SFA 611 610 R1020 1x10 0.026 1 NO + 1 NC MCB-11 1SFA 611 610 R1011 1x10 0.026 Note: To be used together with MCBH5-00 when Contact Blocks in position 4- and 5- are needed. Also when using MCBH-00 together with Selector Switch and Contact Block in position 3- is needed Contact Blocks with Holder for front mounting For non-illuminated Operators 1 NC MCBH-01 1SFA 611 605 R1110 1x10 0.019 1 NO MCBH-10 1SFA 611 605 R1101 1x10 0.019 2 NC MCBH-02 1SFA 611 605 R1120 1x10 0.032 2 NO MCBH-20 1SFA 611 605 R1102 1x10 0.032 1 NO + 1 NC MCBH-11 1SFA 611 605 R1111 1x10 0.032 Contact Block Micro Switch Blocks Holders for Contact Block Double Contact Blocks Modular Range Section 2.5.2 HOA Switch DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Electrical Enclosure 2.6 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Saginaw Control & Engineering 95 Midland Road Saginaw, MI 48638-5770 Phone: (800)234-6871 Fax: (989)799-4524 http://www.saginawcontrol.com Part Information - SCE-30EL2010LP SCE-30EL2010LP Application - Designed to house electrical and electronic controls, instruments and components. Provides protection from dust, oil and water. For outdoor application a drip shield is recommended. Construction - • 0.075" carbon steel. • Seams continuously welded and ground smooth. • Flange trough collar around all sides of door opening. • Oil-resistant gasket. • Collar studs provided for mounting optional panels. • Concealed hinge. • Removable and interchangeable doors. • Black quarter turn latches. • Latches are opened or closed with a screwdriver. • Mounting holes in back of enclosure. • Mounting hardware, sealing washer and hole plug included. • Removable print pocket. • Ground studs on door and body. Options - - Optional tamper-resistant inserts are available. - Optional mounting feet available. - Door hardware available. Finish - ANSI-61 gray powder coating inside and out. Optional Subpanels are powder coated white. Industry Standards - (IS2) NEMA Type 4, 12 and Type 13 UL Listed Type 4 and 12 CSA Type 4 and 12 IEC 60529 IP 66 Notes - Interchangeable latches and handles available in the accessory section. Product Specifications - Part Number: SCE- 30EL2010LP Description: EL Enclosure Height: 30.00" Width: 20.00" Depth: 10.00" Catalog Page: 68 Est. Ship Weight: 53.00 lbs Download CAD Package Add to Bill of Material www.mechatronics.com E-mail: Sales@Mechatronics.com Fax: 425-222-5155 Tel: 425-222-5900 800-453-4569 07/06/05 Model No. Rated Voltage V Sound Noise dB Max Static Pressure (H2O) Air Volume Wt M3 CFM OZ /Min MM INCH UF12A12-_ _H 115 60 12 0.16 0.23 3,100 3.0 106 8.7 0.35 46 18.7 UF12A23-_ _H 230 60 15 0.08 0.12 3,100 3.0 106 8.7 0.35 46 18.7 UF12A12-_ _M 115 60 12 0.17 0.19 2,750 2.6 92 7.0 0.28 42 18.7 UF12A23-_ _M 230 60 15 0.08 0.09 2,750 2.6 92 7.0 0.28 42 18.7 UF12A12-_ _L 115 60 12 0.15 0.16 2,300 2.3 81 4.0 0.16 38 18.7 UF12A23-_ _L 230 60 15 0.07 0.08 2,300 2.3 81 4.0 0.16 38 18.7 UF12A12-_ _S 115 60 8 0.08 0.09 2,100 1.8 64 2.8 0.11 37 18.7 UF12A23-_ _S 230 60 8 0.04 0.05 2,100 1.8 64 2.8 0.11 37 18.7 UF12A12-_ _SL 115 60 6 0.06 0.07 1,800 1.6 57 2.3 0.09 36 18.7 UF12A23-_ _SL 230 60 6 0.03 0.04 1,800 1.6 57 2.3 0.09 36 18.7 Speed RPM Freq. HZ Input Power W Rated Cur. A Locked Cur. A Size: (120 x 120 x 38 mm) 4.69 x 4.69 x 1.5 inches Operating voltage (VAC): 115 or 230 Construction: aluminum die cast frame; UL94V-0 PBT impeller Bearing option: motor quality ball bearings or sintered bronze sleeve Motor: shaded pole Air flow: exhaust over struts Connection: terminal or 22 AWG lead wire Protection: impedance .40 .35 .30 .20 .15 .05 0 20 40 60 80 120 AIR FLOW - CFM STATIC PRESSURE - IN. OF WATER .25 .10 100 Options: • Low EMC Option – If low EMI emissions are a concern for your application, please contact Pfannenberg for our EMC version of these Filterfans. • IP 55, Outdoor/Washdown Option – By using a UV resistant grill, Pfannenbergís new Filterfans meet the European IP55 rating for enclosures. • Rainhood Option – If more security is needed in outdoor or washdown environments then consider our PF-RH-XXXX series. • Special Colors/Voltages – Many of our Filterfans are available is special colors and voltages. Please consult with the factory. Table of Contents NEW FilterFan Introduction 27 New PF PF 11000/22000, PFA 1/20000 44-45 PF 32000, PFA 30000 46-47 PF 42500/43000, PFA 40000 48-49 PF 65/66/67000, PFA 60000 50-51 New PTF PTF 60500/60700/61000 52-53 3rd Gen PF PF Series - 3rd Generation 54-55 PFA Series - 3rd Generation 56 PF-RH Rainhoods 57 Panel Fans 58 NEMA Type 12 Filterfans® Features/Benefits: Patented four-corner “click & fit” system – Enhancing our traditional “click & fit” system, we created an easier to assemble and tighter seal against multiple gauge enclosure sizes. True hardware-free mounting – Our Filterfans do not require any screws to create the pressure on our gasket material to maintain a Type 12 seal against the enclosure. Removing these screws reduce the labor time to mount the Filterfans by greater than 200%. Easy to change filter – The patented hinge system allows for a quick, hands- free change. This reduces the number of lost and damaged grills when they items are placed on floors and carried away from the machine. UL tested NEMA Type 12 rating - Our Filterfans are tested by UL to UL 50 Type 12 and NITW2 categories allowing Integrators to maintain the enclosure ratings of the enclosure while maintaining the high CFM ratings of our original Filterfans. Special Fluted Filter – This special Type 12 filter increases time between maintenance by three times and allows for greater CFM in dirty environments. 43 www.filterfanusa.com Filterfans® Section 2.6.2 Filter Fan DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 44 Filterfan PF 11000-22000 / Exhaust Filter PFA 10000-20000 ● Maintains a UL Tested NEMA Type 12 seal against enclosure ● UL Recognized to UL 508a, category NITW2/8, UL File #E175229, CE approved for European use ● Patented “Click & Fit” design provides a hardware free installation! ● Plastic made from strong, heat resistant (ABS-FR), UL 94 VO fire approved material Options: EMC, IP55, Light Grey or Black Grills Airflow data PF 11000 PF 22000 PFA 10000 PFA20000 Filter material Type 12 filter mat Type 12 filter mat Type 12 filter mat Unimpeded airflow 17 CFM 38 CFM - Capacity free-flow 10 W/K 21 W/K - Airflow in combination 11 CFM 28 CFM - (Filterfan + Exhaust Filter) (PF 22000 + PFA 20000) (PF 22000 + PFA 20000) Capacity in combination 6 W/K 15 W/K - (Filterfan + Exhaust Filter) (PF 22000 + PFA 20000) (PF 22000 + PFA 20000) Max. static pressure (Airflow = 0 m3/h) 38 Pa 57 Pa - Filtration efficiency 88% 91% 88/91% Filter material grade G 3 (DIN EN 779) G 4 (DIN EN 779) G3/ G4 (DIN EN 779) Duty cycle 100% 100% Technical data PF 11000 PF 22000 PFA 10000/ AC DC AC DC PFA 20000 Outside dimensions in mm 109 x 109 x 62 109 x 109 x 49 145 x 145 x 70 145 x 145 x 64 109 x 109 x 26/ (height x width x installation depth) 145 x 145 x 26 Bearing type sleeve bearings ball bearings sleeve bearings ball bearings - Fitting position vertical any vertical any - Construction housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 VO Weight 0.55 kg 0.16 kg 0.7 kg 0.44 kg 0.06 kg / 0.12 kg Safety protection in accordance with DIN 31 001 - Color RAL 7035, RAL 7032 or black, other colors on request Connection terminal strip 2 wires, 310 mm long - System of protection NEMA Type 12, IP 55 (EN 60 529), when installed as specified Electrical data PF 11000 PF 22000 AC AC DC AC AC DC Rated voltage 230 V 115 V 24 V 230 V 115 V 24 V Power consumption 11 W 11 W 2W 18W 20W 5W NEMA Type Approvals Mounting DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 PF 22000 Filterfans® 45 Mechanical data: PF 22000 PF 22000 + PFA 20000 PFA 20000 Cutout Installation cutout 92 mm x 92 mm* standard punch size Static pressure increase Airflow data: PF 11000 .098 .086 .074 .061 .049 .037 .025 .012 0 0 3 6 9 12 15 18 [CFM] Airflow [in •H2 O] PFA 10000 PF 11000 Static pressure increase .172 .147 .123 .098 .074 .049 .025 0 Airflow [in •H2 O] PFA 20000 PF 22000 Installation cutout 125 mm x 125 mm* Mechanical data: PF 11000 PF 11000 + PFA 10000 PFA 10000 Cutout DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 3Instrumentation DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Pressure sensors PX3234 Electronic pressure sensor PX Quick disconnect Process connection ¼''NPT A / M5 I e1 compliant Analog output Measuring range 0...200 PSI Made in Germany Application Type of pressure: relative pressure Liquids and gases Electrical design DC Output 4...20 mA analog Operating voltage [V] 9.6...32 DC Reverse polarity protection yes Overload protection yes Analog output 4...20 mA Load for analog output [Ω] max. (Ub - 9.6 V) x 50; 720 at Ub = 24 V Pressure rating [PSI] 1087 Bursting pressure min. [PSI] 2175 Accuracy / deviations (in % of the span) Characteristics deviation *) < ± 0.35 (BFSL) / < ± 0.75 (LS) Repeatability **) < 0.1 Long-term stability ***) < ± 0.05 Temperature coefficients (TEMPCO) in the temperature range 0...80° C (in % of the span per 10 K) Greatest TEMPCO of the zero point 0.15 Greatest TEMPCO of the span 0.2 ifm efector, inc. 782 Springdale Drive, Exton, PA 19341 — We reserve the right to make technical alterations without prior notice. — US — PX3234 — 30.04.2009 Section 3.1 Pressure Transmitter DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 PX3234 Step response time analogue output [ms] 3 Ambient temperature [°C] -25...80 Medium temperature [°C] -25...90 ****) Storage temperature [°C] -40...100 Protection IP 65, III Insulation resistance [MΩ] > 100 (500 V DC) Shock resistance DIN IEC 68-2-27: 50 g (11 ms) Vibration resistance DIN IEC 68-2-6: 20 g (10...2000 Hz) Min. pressure cycles 100 million EMC EN 61000-4-2 ESD: 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated: 30 V/m EN 61000-4-4 Burst: 2 kV EN 61000-4-6 HF conducted: 10 V radiation of interference according to the automotive directive 2004/104/EC / CISPR25 noise immunity according to the automotive directive 2004/104/EC / ISO 11452-2 HF radiated 100 V/m pulse resistance according to ISO7637-2 / severity level 3 Housing materials stainless steel 316L / 1.4404; FPM (Viton); PA; EPDM/X (Santoprene) Materials (wetted parts) stainless steel (303S22); ceramics; FPM (Viton) Connection M12 connector; gold-plated contacts Weight [kg] 0.218 Remarks *) BFSL = Best Fit Straight Line / LS = Limit Value Setting **) with temperature fluctuations < 10 K ***) in % of value of measuring range / 6 months ****) -40...90 °C upon request Wiring ifm efector, inc. 782 Springdale Drive, Exton, PA 19341 — We reserve the right to make technical alterations without prior notice. — US — PX3234 — 30.04.2009 PX3234 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 376 www.midlandmetal.com Toll Free Phone 1-800-821-5725 2-1/2” FACE 1/4” CENTER BACK MOUNT 4” FACE 1/4” LOWER MOUNT /LTXLG¿OOHGJDXJHVHQKDQFHWKHUHOLDELOLW\DQGLQWHJULW\RIWKHPHDVXULQJV\VWHPIRUORQJSHULRGV7KHJO\FHULQH¿OOLQJKHOSVGDPSHQ the effects of vibration and pulsation. It also lubricates the movement which extends the life of the gauge. 2-1/2” FACE 1/4” LOWER MOUNT 1-1/2” FACE 1/8” LOWER MOUNT LIQUID FILLED GAUGES CENTER BACK MOUNT STAINLESS CASE Part # PSI 80-061 0-15 80-062 0-30 80-063 0-60 80-064 0-100 80-065 0-160 80-066 0-200 80-067 0-300 80-068 0-400 80-069 0-600 80-100 0-1000 80-101 0-1500 80-102 0-2000 80-103 0-3000 80-104 0-5000 80-105 0-10000 80-080 30-0 Vacuum 80-081 -30 to +30 Part # PSI 80-601 0-15 80-602 0-30 80-603 0-60 80-604 0-100 80-605 0-160 80-606 0-200 Part # PSI 80-201 0-15 80-202 0-30 80-204 0-60 80-203 0-160 80-205 0-100 80-206 0-200 80-207 0-300 80-208 0-400 80-209 0-600 Part # PSI 80-463 0-100 1-1/2” FACE 1/8” CENTER BACK MOUNT Part # PSI 80-611 0-15 80-612 0-30 80-613 0-60 80-614 0-160 80-615 0-100 RRRRRRRR R RRRRRRRRR Flow monitors SC0501 22 87 72 58 41 20,6 15 Compact type ½"NPT Quick disconnect Preset switch point Application water Electrical design AC / DC Output normally open Operating voltage [V] 24 AC / DC ± 15% (AC: 47...63 Hz) ¹) Current rating [mA] 80 AC / DC Short-circuit protection — Reverse polarity protection / overload protection — Voltage drop [V] < 4 Current consumption [mA] < 60 Pressure rating [bar] 21 Medium temperature [°C] -10...+60 Adjustment of the switch point preset switch point (15 cm/s) Power-on delay time [s] 15 Response time [s] < 10 (0...100 cm/s) Operating temperature [°C] -20...+70 Protection IP 67, III Housing material stainless steel (303S22) Material sensor surface stainless steel (303S22) Connection M12 connector Wiring 4 21 3 L1 / L+ N / L- 1 3 4 Remarks ¹) to EN50178, SELV, PELV; referring to UL: “limited voltage” with overcurrent protection in accordance with UL508 All data refer to water (25°C) and mounting in 4" pipe. Storage temperature: -40...+70°C efector, inc., 805 Springdale Dr., Exton, PA 19341 We reserve the right to make technical alterations without prior notice . US - SC0501 24.05.2004 Section 3.3 Flow Switch DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 4 Pump & Motor Data DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Engineering Data Pump Code: Pump Shut Off Head: Max. Temperature: Pump Size: Motor Speed: Liquid: Motor Code: System Input Pow er: Max. Frequency: Electrical Enclosures: Discharge: Approximate Net Weight: Suction Size: Impeller Type: Impeller Size: Sense of Rotation: Motor Standard: 3BF1J2B0 1 1/2 x 2 - 6 133 ft 3450 rpm 212 °F C10741 2" 1 1/2" 66 lb 60 ODP NEMA 3~ 208 V Radial impeller Clockwise from the drive end 55/8" Suction Flange Rating: 175 PSI Discharge Flange Rating: 175 PSI Impeller Construction: Closed Motor Rated Horsepower:5.00 hp Shaft Seal: Carbon/Ceramic/BUNA-N Water Impeller Material: Suction Flange Standard:NPT Discharge Flange Standard:NPT Pump Max Horsepower: 4.8119 hp Silicon Bronze (ASTM B584, C87500) Pump Horsepower at Rating Point: 4.18 hp Standard Equipment / Capability: Features and Benefits The 3656 and 3756 S-Group pumps from Goulds have been designed with technical benefits to meet the needs of users in a variety of water supply, recirculation, and cooling applications. The model 3656 offers close coupled design for space saving and simplified maintenance. The model 3756 offers a bearing frame mounted design for flexibility of installation and drive arrangements. Back pull-out to reduce maintenance down time. Standard Type 21 mechanical seal for both reliability and availability. Carbon/ceramic/ BUNA standard, with other faces and elastomers available. 3656/3756 available in all iron, bronze fitted or all bronze construction for application versatility. Replaceable wearing components include stainless steel shaft sleeve and casing and hub wear rings to maintain peak efficiency. Packed box sealing is also available as an option. Enclosed impeller design, dynamic balancing and renewable wear rings reduce losses affecting Head Efficiency NPSH-values Shaft pow er P2 Ø 5 15/16 72.8% Eff. 71% Ø 4 3/4 68.8% Ø 5 5/8 72.6% Application range 107 ft 72.5 % 8.61 ft 4.18 hp 116 US g.p.m. 40% 50% 50% 60% 60% 65% 65% 70% 72% Ø 4 3/4 Ø 5 15/16 Ø 5 5/8 107 ft 72.5 % 8.61 ft 4.18 hp 116 US g.p.m. Ø 4 3/4 Ø 5 Ø 5/8 5 15/16 107 ft 72.5 % 8.61 ft 4.18 hp 116 US g.p.m. Ø 5 15/16 (P2) Ø 4 3/4 (P2) Ø 5 5/8 (P2) 107 ft 72.5 % 8.61 ft 4.18 hp 116 US g.p.m. 0 10 20 30 40 50 60 70 80 90 100 110 Dimension Value Dimension Value A 61/2 H 7/16 AB max 57/8 L 101/2 B 61/2 R 11/4 CP max 263/4 Suction 2 NPT D 41/2 W 41/4 DC max 41/4 X 41/2 DD 31/2 Y 25/8 Discharge 1.5 NPT Z 31/2 E 33/4 F 21/4 G 3/16 Unit Dimensions 2018-07-31 3656 S Bronze Fitted MODEL : 3BF1J2B0 Printed from data f ile End Suction Cast Iron Pumps Voltage / Phase / Enclosure Model 3656/3756 S Group 1003BF1J2B0 US g.p.m. 133 ft 208-230V 3PH ODP Hydraulic Data NPSH Motor Data Qty. Maximum Flow Maximum TDH Submittal Prepared for: Engineer: Submittal Prepared by: Submittal Date: Job: Contractor: Company: 2018-07-31 Approved by: Date: 173ft US g.p.m. 9 1 Flow at Duty Point TDH at Duty Point 80 ft R DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 5 Valves DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 N(P.C.D) G - I H K & % $ F E L B1 B1 SIZE A B C E F H I K L B1XB1 J N 4-0d1 2 1.97 2.25 2.37 0.63 0.31 4.69 2.48 1.18 3.24 0.43 3.54 2.76 0.39 2.5 2.40 2.72 2.87 0.63 0.31 4.92 2.70 1.18 3.81 0.43 3.54 2.76 0.39 3 3.07 3.34 3.50 0.63 0.31 5.18 3.15 1.18 3.81 0.43 3.54 2.76 0.39 4 3.98 4.33 4.50 0.63 0.38 5.94 3.70 1.18 4.56 0.43 3.54 2.76 0.39 5 5.00 5.39 5.56 0.63 0.38 6.75 4.25 1.18 5.81 0.55 3.54 2.76 0.39 6 5.91 6.46 6.63 0.63 0.38 7.20 4.84 1.18 5.81 0.55 3.54 2.76 0.39 8 7.95 8.44 8.63 0.75 0.44 8.09 5.88 1.57 6.25 0.67 4.92 4.02 0.47 10 9.96 10.56 10.75 0.75 0.50 9.84 7.32 1.57 6.25 0.87 4.92 4.02 0.47 12 11.96 12.53 12.75 0.75 0.50 10.83 8.39 1.57 6.44 0.87 4.92 4.02 0.47 Drawing Title: Date: 07/27/2015 Drafted By: AB BFV-B-GVNL-(SIZE)- Phone # 541.564.7636 Fax # 541.564.6522 Please refer to Section 1.1 - Station Drawing for dimensions and operator type. Section 5.1 - Butterfly Valves DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 www.valmatic.com Silent Operation Proven Performance Cost Effective Certified Lead-Free NSF/ANSI 61 & 372 Certified Silent Check Valves ilent Check Valve Bulletin 1400/1800 Section 5.2 Check Valves DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Installation Dimensions A B NPT End Connection BOLT CIRCLE FOR: 2”-10” ANSI CLASS 125 8”-10” ANSI CLASS 250 50-150 MM PN 10/16 BOLT CIRCLE FOR: 2”-6” ANSI CLASS 250 4 Series 1400A - Wafer Series 1400THR - Threaded Dimensions - Inch Valve Size CWP (psig) ANSI Class A B Weight (lb) 2* 400 125/250 4.25 2.63 6 2 1/2* 400 125/250 5.00 2.88 7 3* 400 125/250 5.75 3.13 11 4* 400 125/250 7.00 4.00 19 5* 400 125/250 8.75 4.75 28 6* 400 125/250 9.75 5.50 41 8 200 125 13.38 6.50 81 400 250 13.38 6.50 89 10 200 125 16.00 8.25 99 400 250 16.00 8.25 137 Dimensions Valve Size (NPT) CWP psig (Bar) A in (mm) B in (mm) Weight lb (kg) 1/2 250 (17.2) 2.06 (52.3) 1.38 (35.0) .38 (.17) 3/4 250 6 Valve Construction PRESSURE RATINGS MATERIALS OF CONSTRUCTION MAXIMUM PRESSURE RATINGS SERIES DESCRIPTION SIZE RANGE END CONNECTION CWP psig (Bar) 1400THR Threaded 1/2” - 2” (15-50mm) Threaded NPT 250 (17.2) 1400A Wafer Style 2” - 6” (50-150mm) Wafer Class 125/250 400 (27.6) 8” - 10” (200-250mm) Wafer Class 125 200 (13.8) 8” - 10” (200-250mm) Wafer Class 250 400 (27.6) 1800 Globe Style 2 1/2” - 12” (65-250mm) Flanged Class 125 200 (13.8) 14” - 42” (300-1050mm) Flanged Class 125 150 (10.3) 2 1/2” - 12” (65-250mm) Flanged Class 250 400 (27.6) 14” - 42” (300-1050mm) Flanged Class 250 300 (20.7) V PROVIDING SYSTEM EFFICIENCY AND PROTECTION AIR VALVES Bulletin 1500 NSF/ANSI 61 Certified Section 5.3 Air Release Valve DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 12 Operational Highlights: • Maintains system flow efficiency • Releases unwanted air pockets during system operation • Protects system against air related surges Product Features: • Unconditionally guaranteed stainless steel floats • Stainless steel 316 internal trim • Resilient seating for positive shutoff • Performance proven for over 40 years • Non-clog design eliminates backwashing Optional Accessories: • Vacuum check (prevents inflow of air) • Outlet hood with screen (prevents debris from entering valves) • Ball and plug isolation valves (allows valve maintenance) • Inflow Preventer on outlet (stops flood water and resulting contamination from entering pipeline) • Backwash kit (for severe wastewater applications) MATERIALS OF CONSTRUCTION COMPONENT STANDARD OPTIONAL Body and Cover Cast Iron ASTM A126 Class B < 300 psig Ductile Iron ASTM A536 Grade 65-45-12 Stainless Steel ASTM A351 Grade CF8M Trim Type 316 Stainless Steel -- Coating Universal Alkyd Primer (external) Non-Stick Fusion Bonded Epoxy (internal & external) Venting Capacity for Air Release Valve Orifice Sizes Air Release Valves Clean Water* Wastewater * * REFER TO DRAWING* DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 13 WATER AIR RELEASE VALVES Inlet Size Outlet Size Model Number CWP PSI Orifice Size Dimensions A B 1/2” NPT 1/2” NPT 15A*• 175 1/16” 4 3/4” 5 1/4” 3/4” NPT 1/2” NPT 15A.2*• 175 1/16” 4 3/4” 5 1/4” 1” NPT 1/2” NPT 15A.3*• 175 1/16” 4 3/4” 5 1/4” 1” NPT 1/2” NPT 22.3*• 175 3/32” 5 1/8” 6” 1/2” - 3/4” NPT 1/2” NPT 22.4*• 175 3/32” 5 1/8” 6” 1/2” NPT 1/2” NPT 22.7*• 300 1/16” 5 1/8” 6” 1/2” - 1” NPT 1/2” NPT 22.9* 300 1/16” 5 1/8” 6” 3/4” - 1” NPT 1/2” NPT 25.5* 150 1/8” 6 1/8” 7” 3/4” - 1” NPT 1/2” NPT 25.6* 300 3/32” 6 1/8” 7” 1” NPT 1/2” NPT 38* 150 3/16” 7” 10” 1” NPT 1/2” NPT 38HP* 500 1/8” 7” 10” 2” NPT 1/2” NPT 38.2* 150 3/16” 7” 10” 1” NPT 1/2” NPT 38.5* 300 5/32” 7” 10” 2” NPT 1/2” NPT 38.6* 300 5/32” 7” 10” 2” NPT 1” NPT 45* 150 23/64” 9 1/2” 12 1/4” 2” NPT 1” NPT 45HP* 400 3/16” 9 1/2” 12 1/4” 3” NPT 1” NPT 45.2* 150 23/64” 9 1/2” 12 1/4” 2” NPT 1” NPT 45.5* 300 7/32” 9 1/2” 12 1/4” 3” NPT 1” NPT 45.6* 300 7/32” 9 1/2” 12 1/4” 2” NPT 1” NPT 50* 500 7/32” 10 7/8” 13” 2” NPT 1” NPT 50HP* 1000 1/8” 10 7/8” 13” 6” 125lb Flg 1” NPT 61* 150 1” 18 3/4” 22” Installation Dimensions A B A B 15A - 50HP Air Release Valve 48A - 49A.6 Wastewater Air Release Valves *NSF/ANSI 61 Certified •UL Listed/FM Approved B A 61 Air Release Valve Air Release Valves WASTEWATER AIR RELEASE VALVES Inlet Size Outlet Size Model Number CWP PSI 6 Miscellaneous DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Jet Rite 2 Well Tanks In addition to their bulletproof design, Jet Rite 2 tanks are made with a stainless steel system connection. And they are finished with an appliance-quality paint to help them withstand even the harshest outdoor elements. They are also available in both vertical and horizontal models providing unlimited installation flexibility. Materials of Construction Tank: 16- gauge cold rolled steel Finish: Appliance-quality paint for indoor or outdoor installation Water chambers: 100% butyl rubber, virgin polypropylene liner Connection: Stainless steel Testing: High pressure, seam weld, helium, final precharge check Air valve: Brass valve with O-ring seal Warranty: Five year Warranty Information Steel Well Tanks Warranty Dimension Table Model Volume (Gal.) Volume (Liter) Acceptance (Gal.) Acceptance (Liter) A (in.) A (cm.) B (in.) B (cm.) C (in.) C (cm.) D (in.) D (cm.) Weight (lbs) Weight (kg) PJR 6 2.1 8 .8 3.2 12.0 30.0 8.0 20.0 .75 NPT 1.91 NPT - - 5.0 2.3 PJR 15 4.8 18 1.9 7.2 14.5 37.0 11.0 28.0 .75 NPT 1.91 NPT - - 10.0 4.6 PJR 20S 5.3 20 2.1 8 17.5 44.4 11.4 28.9 .75 NPT 1.91 NPT - - 13.3 6.0 PJR 25S NPT NPT PJR 44IL 14.0 53 5.6 21.2 19.75 50.0 15.3 39.0 1 NPT 2.54 NPT - - 23.3 10.6 PJR 44S 14.0 53 5.6 21.2 20.8 52.8 16.3 41.4 .75 NPT 1.91 NPT - - 27.0 12.3 PJR 66S 20.0 76 8.0 32 28.5 72.4 16.3 41.4 1 NPT 2.54 NPT - - 38.0 17.2 Sizing Chart Table Model Volume (Gal.) Volume (Liter) Replacable Bladder 20/40 (Gal.) 20/40 (Liter) 30/50 (Gal.) 30/50 (Liter) 40/60 (Gal.) 40/60 (Liter) PJR 6 2.1 8 no .8 3.0 .7 2.6 .6 2.3 PJR 15 4.8 18 no 1.7 6.4 1.5 5.7 1.3 4.9 PJR 20S 5.3 20 no 1.9 7.2 1.6 6.0 1.4 5.3 PJR 25 (S) 9.0 34 no 3.1 11.7 2.6 9.8 2.3 8.7 PJR 44 (S) 14.0 53 no 5.1 19.3 4.3 16.3 3.8 14.4 PJR 44 IL 14.0 53 no 5.1 19.3 4.3 16.3 3.8 14.4 PJR 66S 20.0 76 no 7.6 28.8 6.5 24.6 5.5 20.8 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 25 9.0 34 3.6 12.8 18.9 48.1 12.5 31.8 .75 NPT 1.91 NPT - - 15.4 7.0 PJR 9.0 34 3.6 12.8 18.9 48.1 12.5 31.8 .75 1.91 - - 15.4 7.0 Section 6.1 Pressure Tank DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Orifice Size Dimensions A B 2” NPT 1/2” NPT 48A 150 3/16” 7” 15 5/16” 3” NPT 1/2” NPT 48A.2 150 3/16” 7” 15 5/16” 2” NPT 1/2” NPT 48A.4 75 5/16” 7” 15 5/16” 3” NPT 1/2” NPT 48A.5 75 5/16” 7” 15 5/16” 2” NPT 1” NPT 49A 150 7/16” 9 1/2” 17 9/16” 3” NPT 1” NPT 49A.2 150 7/16” 9 1/2” 17 9/16” 2” NPT 1” NPT 49A.4 75 1/2” 9 1/2” 17 9/16” 3” NPT 1” NPT 49A.5 75 1/2” 9 1/2” 17 9/16” 4” NPT 1” NPT 49A.6 75 1/2” 9 1/2” 17 9/16” Please refer to Section 1.1 - Station Drawing for dimensions. DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 COMPONENT STANDARD OPTIONAL Body Cast Iron Stainless Steel Ductile Iron Disc Lead-Free Bronze Al-Bronze (Lead-Free) Stainless Steel Seat Lead-Free Bronze Al-Bronze (Lead-Free) Stainless Steel Resilient Seat - Buna-N EPDM Spring T316 Stainless Steel Heavy Duty Spring Headloss Chart COMPONENT STANDARD Body Lead-Free Bronze Disc Lead-Free Bronze Seat Teflon Spring T316 Stainless Steel Threaded Style Wafer & Globe Style Size 2 2-1/2 34568 10 12 14 16 18 20 24 30 36 42 Wafer Cv 43 88 130 228 350 520 900 1450 - - - - - - - - - Globe Cv - 127 155 278 435 625 1115 1770 2500 3400 4400 5600 6900 10,000 15,400 22,400 30,400 10 8 7 6 5 4 3 2 1 .8 .7 .6 .5 .4 .3 10 20 30 40 50 60 70 80 100 200 300 400 500 600 700 800 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 10,000 40 50 60 70 80 100 200 300 400 500 600 700 800 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 .08 .1 .2 .3 .4 .5 .6 .7 .8 1 2 3 4 5 HEAD LOSS IN FEET OF WATER FLOW OF WATER IN GALLONS PER MINUTE CUBIC METERS PER HOUR METERS OF WATER 4 F E E T / S E C O N D V E L O C I T Y 12 FEET/SECOND VELOCITY 21/2” 3” 4” 5” 6” 8” 10” 12” 14” 16” 18” 20” 24” 30” 36” 42” TYPICAL GLOBE SIZING RANGE 10 8 7 6 5 4 3 2 1 .8 .7 .6 .5 .4 .3 6 7 8 10 20 30 40 50 60 70 80 100 200 300 400 500 600 700 800 30 40 50 60 70 80 100 200 300 400 500 600 700 800 1,000 2,000 3,000 4,000 .08 .1 .2 .3 .4 .5 .6 .7 .8 1 2 3 4 5 HEAD LOSS IN FEET OF WATER FLOW OF WATER IN GALLONS PER MINUTE CUBIC METERS PER HOUR METERS OF WATER TYPICAL WAFER SIZING RANGE 4 F E E T / S E C O N D V E L O C I T Y 10 FEET/SECOND VELOCITY 2” 2 1/2” 3” 4” 5” 6” 8” 10” Wafer Style Globe Style ilent Check Valve DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 (17.2) 2.25 (57.1) 1.63 (41.4) .48 (.22) 1 250 (17.2) 2.63 (66.8) 2.00 (50.8) .81 (.37) 1 1/4 250 (17.2) 2.94 (74.6) 2.38 (60.4) 1.22 (.55) 1 1/2 250 (17.2) 3.31 (84) 2.75 (69.8) 1.61 (.73) 2 250 (17.2) 3.68 (93.4) 3.38 (85.8) 5.13 (2.33) Dimensions - Metric Valve Size CWP (Bar) PN Class A B Weight (kg) 50 27.6 10/16 107.9 66.8 3 65 27.6 10/16 127 73.1 4 80 27.6 10/16 146 79.5 5 100 27.6 10/16 177.8 101.6 9 125 27.6 10/16 222.2 107.9 13 150 27.6 10/16 247.6 139.7 19 *Note: Sizes 2 - 6 in. are dual rated to fit between both ANSI Class 125 and 250 flanges. Please refer to Section 1.1 - Station Drawing for dimensions. DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 120 130 140 150 160 170 [ft] 10 20 30 40 50 60 [%] 4 8 12 16 [ft] 1 2 3 4 5 [hp] 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 [US g.p.m.] 1 Fluid: Water Duty Chart: 3500 RPM Performance Data 2018-07-31 3656 S Bronze Fitted MODEL : 3BF1J2B0 Printed from data f ile End Suction Cast Iron Pumps Voltage / Phase / Enclosure Model 3656/3756 S Group 1003BF1J2B0 US g.p.m. 133 ft 208-230V 3PH ODP Hydraulic Data NPSH Motor Data Qty. Maximum Flow Maximum TDH Submittal Prepared for: Engineer: Submittal Prepared by: Submittal Date: Job: Contractor: Company: 2018-07-31 Approved by: Date: 173ft US g.p.m. 9 1 Flow at Duty Point TDH at Duty Point 80 ft R DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 performance and pump life. Suction and discharge pipe connections are NPT threaded, except 3 x 4 7 which has 125 lb. ANSI flat faced flanges. Rigid cast iron motor adapter provides support and registered fits maintain positive unit alignment. Standard NEMA motor frame, JM or JP shaft extension, C-face mounting, single phase or three phase, 3500 or 1750 RPM. Open drip proof and totally enclosed fan cooled. Optional explosion proof or high efficiency motors available. Optional rigid carbon steel bedplate, sheet metal coupling guard and T. B. Woods spacer coupling for 3756 models. Submittal Data 2018-07-31 3656 S Bronze Fitted MODEL : 3BF1J2B0 Printed from data f ile End Suction Cast Iron Pumps Voltage / Phase / Enclosure Model 3656/3756 S Group 1003BF1J2B0 US g.p.m. 133 ft 208-230V 3PH ODP Hydraulic Data NPSH Motor Data Qty. Maximum Flow Maximum TDH Submittal Prepared for: Engineer: Submittal Prepared by: Submittal Date: Job: Contractor: Company: 2018-07-31 Approved by: Date: 173ft US g.p.m. 9 1 Flow at Duty Point TDH at Duty Point 80 ft R DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 80-616 0-200 •Liquid Filled Gauges with a stainless case are used for protection in harsh environments. •Stainless Steel Case •Copper Alloy Wetted parts •Polycarbonate window + 1.5% of span accuracy • Temp. Range -104°F to 158°F GAUGES PNEUMATICS ACCSESSORIES Section 3.2 Pressure Gauges DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 L M H SL S L M H UF12A series TERMINAL TYPE LEAD WIRE 4.69 ±0.04 (120) 4.12 ±0.01 (104.8 ±0.3) 0.17 (Ø4.2) Nom. 11.8 (300) (8.5) (8) (3) 1.50 ±0.02 (38) (4) (Ø114) Section 2.6.2 Filter Fan DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Optional Accessories - SCE-30P20 - Supbanel, Bent SCE-DS20N4 - Shield, Drip **Optional drip shield. SCE-ELMFK4 - Kit, EL Mounting Feet (4pc.) SCE-PLWKB - Padlocking Wingknob Door Latch (Black) Section 2.6.1 Electrical Enclosure DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Alt.2 • Operator + Holder with Contact Block(s) 1SFC151079F0001 Contact Blocks Holder Operator (with Locking Nut) Bezel Modular Range Bezel Options Type Order Code Black Plastic M3SS(X)-10X 1SFA611 21X R10XX Chrome Metal M3SS(X)-30X 1SFA611 21X R30XX Bezel - How to order Black Plastic - Standard Chrome Metal - Replace ‘1’ with ‘3’ in Type and Order Codes Section 2.5.2 HOA Switch DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 D50-230/4003Y D50-240/4153Y 120/240VAC Three ĭ High Leg Delta D50-120/240HL 120/208VAC Three ĭ Wye D50-120/2083Y D50-127/2203Y 120/240VAC Split ĭ D50-120/2401 D50-120/240HD Service Wiring D50 Series Industrial Surge Protection Document: SPS-100073-001 Rev 2 09-11 ©2010 DITEK Corp. Specification Subject to Change Dimensions: Option Codes: Ordering Example: 3.5”H x 3.5”W x 2.4”D Flush Mount Kit: D50-120/2083Y: D50 for 50kA, (89mm x 89mm x 61mm) D50-FMK 3 Wye for 4W+G, 120/208V system Conduit fitting: ½” threaded NPT Outdoor Rated Conduit and Nipple Flush Mount Plate Option Section 2.4.2 Surge Protection DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 1/8 2/10 3/10 1/2 3/4 8/10 1-1/4 1-1/2 1-6/10 2-1/4 3-1/2 (2/10) (4/10) (6/10) (8/10) (1-1/4) (1-6/10) (2) (2-1/2) (2-8/10) (4) (6-1/4) Primary VA Rating voltage 25 50 75 100 150 200 250 300 350 500 750 If the rated primary current is less than 2 amps, the maximum rating of the overcurrent device is 300% for power circuits, shown above, or 500% for control circuits, shown above in (brackets). If the rated primary current is 2 amps or more, the maximum rating of the overcurrent device is 250%. All figures assume secondary overcurrent protection per UL/NEC. Reference: NEC 430 - 72(c) exception #2, 450-3(b) 1 & 2, UL508 32.7, UL845 11.16 & 11.17. If the rated secondary current is less than 9 amps, the maximum rating of the overcurrent device is 167%; 9 amps or more, the maximum rating of the overcurrent device is 125%. If 125% does not correspond to a standard fuse rating, the next highest standard rating may be used. Reference: NEC 430 - 72(c) exception #2, 450-3(b) 1 & 2, UL508 32.7, UL845 11.16 & 11.17. Maximum acceptable rating of secondary overcurrent protection 23 1-8/10 3-1/2 5 7 10 12 15 20 20 30 45 24 1-6/10 3-2/10 5 6-1/4 10 12 15 20 20 30 40 25 1-6/10 3-2/10 5 6-1/4 10 12 15 15 20 25 40 90 4/10 8/10 1-1/4 1-8/10 2-1/2 3-1/2 4-1/2 5 6-1/4 9 12 95 4/10 8/10 1-1/4 1-6/10 2-1/2 3-1/2 4 5 6 8 12 100 4/10 8/10 1-1/4 1-6/10 2-1/2 3-2/10 4 5 5-6/10 8 12 110 3/10 3/4 1-1/8 1-1/2 2-1/4 3 3-1/2 4-1/2 5 7-1/2 10 115 3/10 6/10 1 1-4/10 2 2-8/10 3-1/2 4 5 7 10 120 3/10 6/10 1 1-1/4 2 2-1/2 3-2/10 4 4-1/2 6-1/4 10 220 15/100 3/10 1/2 3/4 1-1/8 1-1/2 1-8/10 2-1/4 2-1/2 3-1/2 5-6/10 230 15/100 3/10 1/2 6/10 1 1-4/10 1-8/10 2 2-1/2 3-1/2 5 240 15/100 3/10 1/2 6/10 1 1-1/4 1-6/10 2 2-1/4 3-2/10 5 Secondary VA Rating voltage 25 50 75 100 150 200 250 300 350 500 750 Section 2.4.1 Transformer DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 2000 X42K1 17.39 81/4 210 63/4 171 511/16 144 51/4 133 61/16 154 9/32 x 9/16 7 x 14 3000 X43K1 26.09 89/16 217 9 229 71/2 191 53/4 147 71/2 191 7/16 x 3/4 11 x 19 5000 X45K1 43.48 101/2 267 9 229 103/16 259 61/2 165 61/2 165 7/16 x 3/4 11 x 19 X4045SF1 T41K1 X4750PSF1 Covers Description Catalog number List price Terminal covers TPTC-1001 $ 39 Primary fuse covers TPTC-2006 26 Section 2.4.1 Transformer DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 XT1 125A MCP (MA) Fixed (F) - 3 poles - Front terminals (F) - UL/CSA Magnetic trip unit Int Rtng (480V) H 65kA Type In I3 Part number MCP 3 9…33 XT1HU3003MFF000XXX 7 21…77 XT1HU3007MFF000XXX 15 45…165 XT1HU3015MFF000XXX 30 90…330 XT1HU3030MFF000XXX 50 150…550 XT1HU3050MFF000XXX 70 210…770 XT1HU3070MFF000XXX 80 240…880 XT1HU3080MFF000XXX 100 300…1100 XT1HU3100MFF000XXX 125 375…1375 XT1HU3125MFF000XXX DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 20 � S 203-C 20 2CDS 253 001 R0204 46810 7 0.375 1 25 S 203-C 25 2CDS 253 001 R0254 46820 6 0.375 1 32 � S 203-C 32 2CDS 253 001 R0324 46830 5 0.375 1 40 � S 203-C 40 2CDS 253 001 R0404 46840 4 0.375 1 50 S 203-C 50 2CDS 253 001 R0504 55106 9 0.375 1 63 S 203-C 63 2CDS 253 001 R0634 55107 6 0.375 1 Umax 253 V 72 V ... Umax 440 V 125 V ... � Umax 440 V Selection tables MCBs S 200 series 6000 2CSC400412F0201 2CSC400409F0201 2CSC400408F0201 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 2 ≤ In ≤ 40 2 ≤ In ≤ 40 80 ≤ In ≤ 100 Breaking capacity [kA] Reference standard Nr. poles Ue[V] IEC 23-3/EN 60898 Icn 230/400 6 10 25 15 15 6 4.5 6 10 6 IEC/EN 60947-2 Alternating current Icu 1, 1P+N 133 20 25 � 40 25 25 40 25 25 40 10 15 20 15 230 10 15 � 25 15 15 25 15 15 25 6 10 10 6 2, 3, 4 230 20 25 � 40 25 25 40 25 25 40 10 400 10 15 � 25 15 15 25 15 15 25 6 2, 3, 4 500 690 Ics 1, 1P+N 133 15 18.7 � 20 18.7 18.7 20 18.7 18.7 20 6 10 10 15 230 7.5 11.2 � 12.5 11.2 7.5 12.5 11.2 7.5 12.5 4.5 6 7.5 6 2, 3, 4 230 15 � 18.7 � 20 18.7 18.7 20 18.7 18.7 20 10 400 7.5 11.2 � 12.5 11.2 7.5 12.5 11.2 7.5 12.5 6 2, 3, 4 500 690 IEC/EN 60947-2 Direct current T=I/R≤5ms for all series, except S280 UC and S800S-UC, where T=I/R<15ms Icu 1, 1P+N 24 20 60 10 10 15 10 10 15 10 10 15 10 15 15 10 125 250 2 48 20 125 10 10 15 10 10 15 10 10 15 10 15 15 10 250 500 800 3,4 375 500 750 1200 Ics 1, 1P+N 24 20 60 10 10 15 10 10 15 10 10 15 10 15 15 10 125 250 2 48 20 125 10 10 15 10 10 15 10 10 15 10 15 15 10 250 500 800 3,4 375 500 750 1200 UL 1077/ C22.2 No 235 Alternating current Int. cap. 1, 1P+N 120 10 10 10 10 240 277 610 10 10 2, 3, 4 240 10 10 10 10 480 Y/277 610 10 10 UL 1077/ C22.2 No 235 Direct current Int. cap. 1, 1P+N 60 10 125 250 2, 3, 4 125 250 500 UL 489/ C22.2 No 5 Alternating current Int. cap. 1 240 10 10 10 10 277 10 2, 3, 4 240 10 10 10 10 480 Y/277 10 UL 489/ C22.2 No 5 Direct current Int. cap. 1 60 14 2 125 14 � IEC/EN 60947-3 Icw 2 800 3, 4 1200 � only up to 40 A; � only for “D” characteristic � values are not for all rated currents � 600 V DC for 100, 125 A � 1000 V DC for 100, 125 A � 3 poles 10 kA up to 50/63 A General features and breaking capacities System pro M compact® MCBs NOTE: All the MCBs of S200 series present two values of breaking capacities marked on the product: on the front Icn according to IEC/EN 60898 on the side Icu/Ics according to IEC/EN 60947-2 dependig on the rated current, if not otherwise specified. C DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 30 W Environmental ABB contact for United CPEAmerica 24/1.25 States of Section 2.1.2 PLC Power Supply DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 2 analog O 1 HMISCU6B5 0 .551/ 1.215 5.7" QVGA color TFT 2 USB 1 COM1 1 CANopen 128 MB No 8 digital I/8 digital O 4 analog I/ 2 analog O 1 HMISCU8B5 0 .803/ 1.770 (1) Mounting system for Ø 22 mm hole, power supply and I/O connectors, locking device for USB connector and instruction sheet included with terminals. The setup documentation for Magelis SCU Small controllers is supplied in electronic format with the SoMachine software (please refer to our website www.schneider-electric.com.). DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 3 4 1 2 13 10 12 11 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Communication Downloadable protocols Modbus, Modbus TCP/IP (1) Uni-TE, Modbus, Modbus TCP/IP (1) and for PLC brands: Mitsubishi, Omron, Allen-Bradley and Siemens Asynchronous serial link RS 232C/RS 485 (COM1) RS 232C/RS 422/RS 485 (COM1) RS 232C/RS 422/RS485 (COM1) and RS 485 (COM2) USB ports 1 Host type A + 1 Device type mini-B 1 1 or 2 (1) Buses and networks 1 CANopen master 1 CANopen master with optional module (XBTZGC CAN) 1 CANopen master with external module (XBTZG CANM) which is mandatory for the control function Ethernet TCP/IP (10BASE-T/100 BASE-TX) Ethernet TCP/IP (10BASE-T/100BASE-TX) Ethernet TCP/IP (10BASE-T/100BASE-TX) (1) Printer link USB port for parallel printer USB port for parallel printer USB port for parallel printer and RS 232C (COM1) serial link Design software SoMachine on Windows XP Professional and Windows 7 Professional 343647/64-bit (please refer to our website www .schneider-electric .com) . SoMachine on Windows XP Professional and Windows 7 Professional 343647/64-bit (please refer to our website www .schneider-electric .com) . Operating system Magelis (333 MHz RISC CPU) Magelis (131 MHz RISC CPU) Magelis (131 MHz RISC or 266 MHz RISC CPU) (1) Magelis (266 MHz RISC CPU) Terminal type HMISCU6A5 HMISCU8A5 HMISCU6B5 HMISCU8B5 XBTGC2330T XBTGC2330U XBTGT2p/4p/5p/63/73 + XBTZGCANM XBTGK2p/53 + XBTZGCANM Page 11 For more information, please refer to our website www .schneider-electric .com . (1) Depending on model. 8 .0 2 3 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 Most powders can be reclaimed, sieved and recycled, if proper housekeeping is maintained. PRETREATMENT The substrate pretreatment prior to powder coating is a critical factor in developing maximum corrosion resistance and maximizing the l ifetime of the product. C.R.S. (Iron phosphate): C.R.S. (Zinc phosphate): Galvanized steel (Zinc phosphate): Aluminum (Chromate): Aluminum (phosphate): 2 to 5 stages depending upon soil level, and quality desired. 5 to 9 stages depending upon soil level, and quality desired. 5 to 7 stages depending on soil level, and quality desired. Galvanized steel must be degassed at 5 degrees above cure temperature to minimize gassing. 5 stage system is normally needed. 5 stage system is normally needed. 10 MINUTES @ 400 DEGREES F. 1.64 CALCULATED C11JA RoHS Compliant Section 1.2 Powder Coating PPS Beige DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 43 z 2 BOOSTER SYSTEM PUMP STATION BEATTIE ES 90% Final PART NO: TITLE: PROJECT: MATERIAL B 1 OF 1 REV PRECISION PUMPING SYSTEMS 6515 BUSINESS WAY BOISE, IDAHO 83716 208-323-5300 www.gopps.us LEVEL: DATE: 9/21/2018 SIZE: SCALE: SHEET: UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL: 1/8" ONE PLACE DECIMAL: .10 TWO PLACE DECIMAL: .05 DO NOT SCALE DRAWING DRAWN: JWR NTS 1C-NJ-NF-2 - Piping: SS 304 Skid: STEEL A36 NON-POTABLE NOT FOR FABRICATION JOB: DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 REUSE THOSE GROUNDS AVAILABLE EXISTING METER MT TO REMAIN EXISTING SERVICE LATERAL TO REMAIN EXISTIN PAD MOUNTED TRANSFORMER TO REMAIN REMOVE AND REPLACE FEEDER FROM METER TO PANEL REMOVE EXISTING PANEL AND REPLACE WITH LP11 M Y R O N G U S T G N E L A N O I S S E F O R P C O L O R A D O L I R E E N I C E N S E D 18304 DATE SHEET NO. DESIGNED BY DRAWN BY CHECKED BY REVISIONS 01-17-2018 HYDROMETER RENOVATION BEATTIE ELEM. CITY OF FORT COLLINS FORT COLLINS, CO. - - - - MHG MHG MHG NOT FOR CONSTRUCTION ISSUED FOR CONSTRUCTION E-100 POWER REMODEL PLANS 1/2" = 1'-0" 1 FIRST FLOOR - POWER PLAN MECHANICAL EQUIPMENT SCHEDULE Type Mark Count Description P1 1 NEW PUMP, WIRED BY EC Grand total: 1 ELECTRICAL EQUIPMENT SCHEDULE Type Mark Count Manufacturer Model Description LP11 1 SQUARE D 120/240V SURFACE MOUNT PANELBOARD WITH MAIN LUGS ONLY PCP 1 1 PHASE TO 3 PHASE PUMP CONTROL PANEL ELECTRICAL CIRCUIT SCHEDULE Panel Load Name Circuit Number Wire Size Conduit Size Voltage Voltage Drop VD% MT LP11 1 2-#3, 1-#3, 1-#8 1 1/4" 240 V 0 V 0.048698 LP11 PCP 1,3 2-#8, 1-#8, 1-#10 3/4" 240 V 1 V 0.4147 Grand total: 2 1/4" = 1'-0" 2 FIRST FLOOR - POWER DEMOLITION PLAN 1/4" = 1'-0" ELECTRICAL LEGEND No Scale WIRING LEGEND EXISTING ELECTRICAL EQUIPMENT SCHEDULE Type Mark Count Description MT 1 EXISTING METER TO REMAIN. REMOVED FEED TO EXISTING PANEL AND REPLACE TO NEW PANEL EP 1 EXISTING 100 AMP 120/240 VOLT PANEL TO BE REPLACED WITH NEW PANEL Notes: Total Est. Demand: 0 A Total Conn.: 0 A Total Est. Demand: 0 VA Total Conn. Load: 0 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 24 A 24 A Total Load: 2880 VA 2880 VA 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 2880 VA 4 1 PCP 40 A 2 2880 VA 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: Surface Wires: 3 Mains Rating: 100 A Supply From: MT Phases: 1 Mains Type: M.L.O. Location: Volts: 120/240 Single A.I.C. Rating: 10000 Branch Panel: LP11 No Scale 3 DIRECTIVE FOR PANEL SCHEDULES No Scale 4 GROUNDING ONE LINE, 100 AMP SERVICE No Scale 5 ONE LINE1 DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6 TRANSITION TO CLASS 200 PVC PIPE BELOW GRADE. 2-INCH CLASS 200 PVC PIPE 2"X3" SCH. 40 PVC CONCENTRIC REDUCER 3-INCH CLASS 200 PVC PIPE 3-INCH SCH. 40 PVC 22.5° FITTING CUT EXISTING 3-INCH PVC MAINLINE AND INSTALL SOLVENT WELD SCH. 40 PVC TEE. EXISTING 3-INCH PVC MAINLINE. NOTE: THERE ARE APPROXIMATELY THREE (3) EXISTING REMOTE CONTROL VALVES WITHIN 5-FEET OF THE BUILDING. PUMP CONTROL PANEL: ABB ACS550, 24 AMP VFD IN WALL MOUNT NEMA 1 ENCLOSURE 1-INCH COPPER TEE (ORIENTED VERTICALLY) WITH 1-INCH BRASS BALL VALVE INTENDED FOR WINTERIZATION EXISTING IRRIGATION CONTROLLER (WIRE HYDROMETER TO EXISTING CONTROLLER) 9'-6" 42" PER NEC CODE 36" WIDE DOOR A NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL FIELD CONDITIONS PRIOR TO ORDERING EQUIPMENT. 2. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3. MOTOR, PRESSURE TRANSDUCER, AND CONTROL PANEL TO BE SHIPPED LOOSE AND ASSEMBLED ON SITE BY PUMP MANUFACTURER'S REPRESENTATIVE. REFER TO SPECIFICATIONS. 4. REFER TO ELECTRICAL PLANS FOR ADDITIONAL INFORMATION. 5. INSTALL ONE (1) PIPE SUPPORT STAND (GRAINGER ITEM #25CH16 OR EQUAL) EVERY 5-FEET OF ELEVATED PIPING LOCATED ON DISCHARGE SIDE OF PUMP. B C E D FLOW F G H I J K L 1'-0" M H N O P Q Q ±8' R S T U ±6' ±24" 9'-6" V W A B C D E F G H I J K L M N O P Q R S T U V W DocuSign Envelope ID: 5B5423FC-692F-4B80-B4BF-A3A3D66904F6