Loading...
HomeMy WebLinkAboutCORRESPONDENCE - PURCHASE ORDER - 9146939LryNG BUILDING ENVIRONMENTS to: Biven Wray company: City of Fort Collins from: Doug Kling regarding: Epic Ice Arena We are pleased to quote the following equipment: 1795 W. Yale Avenue Englewood, CO 80110 (970)227-2383 dklingtalong.com Technologyror Better Buildings October 10e1, 2014 delivery terms: FOB Factory. Freight allowed to first destination. payment terms: Net 30 days (with credit approval). Otherwise cash, order acceptance: Conditional on the terms and conditions attxhed. B you do not have them, please request a copy. (1) McQuay Scroll Water Cooled Liquid Chiller Complete with: • Full Charge of R41 OA and oil • Evaporator Insulation • Microtech II Onboard Controls • DP switches • HGBP • Across the Line Starter • Non Fused Disconnect Switch • One Year Parts Warranty • One Year Parts Warranty By Others: Labor Warranty, Extended warranties, Installation of field items, Isolation, bluing external to unit, Curb or Pad, start-up Total Net Price .................... E 46;9t)0 00>'c ......................................... wv# `lb37zs Doug Kling MCCOani5MMN MOMnSCOPEdw Colorado Nevada Utah Wyoming Daikin PDC — TECHNICAL BREAKDOWN Date saved : October 16, 2014 UNIT ELECTRICAL DATA (ETL / Canadian ETL Listed and Labeled)'*" Volts 460 Hertz 60 Single Point' Mufti Point' with external overload Ckt 1 Ckt 2 Ckt 3 MCA 115 8 61 [451 61 45 N/A Field Wire Gauge 2 AWG [3 AWGField 6 AWG 18 AWG] 6 AWG [8 AWG] N/A Wire Qty 3131 3 3 3 3 N/A Conduit Qty 1 [11 1111 1 1 N/A Conduit Nom Size 1.25 [1.001 0.75 [0.51 0.75 0.5 N/A Rec Fuse Size 125 [1001 80 f6ol 80 60 N/A Max Fuse Size 125 [1001 80 f6ol 80 60 WA Terminal Amps for Standard Power Block" 175 175 175 N/A Connector Wire Range for Standard Power Block" (1)2/0-#14 (1)2/0-#14 (1)210-#14 N/A Terminal Amps for Optional Disconnect Switch" 125 100 100 N/A Connector Wire Range for Optional Disconnect Switch" (1)3/0-#3 (1)1/0-#10 (1)110-#10 N/A Both single and multiple point data are shown for user convenience. " Both standard power block and optional disconnect data are shown for user convenience. "' Electrical data does not include items configured in the Job Editor such as a pump package. For all options refer to the order acknowledgement for the actual configuration _ COMPRESSOR ELECTRICAL DATA Type / Quantity Scroll/4 Comp 1 Comp 2 Comp 3 Comp, 4 Comp 5 Comp 5 RLA 26.9 26.9 26.9 26.9 WA NIA LRA Across the Line 173.0 173.0 173.0 173.0 WA N/A Reduced Inrush / Part Winding N/A N/A N/A N/A WA NIA Reduced Inrush / Solid State N/A N/A N/A N/A N/A N/A AHRI 5601690 CERTIFICATION' This unit is certified In accordance with the AHRI Water -Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which Is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org ® 2013 Daikin www.DaikinApplied.com Page 2, P :g i-76: Qoty Daikin PDC -TECHNICAL BREAKDOWN Date saved : October 16, 2014 JOB NAME DH913T REP. OFFICE Lon Building Technologies JOB DESCRIPTION EPIC CHILLER SALESMAN Long Building Technologies CUSTOMER MODEL NUMBER WGZ080D - Standard Efficient UNIT TAGGING CH-1 IVERSION 18.84.001 PHYSICAL DATA Length (ins) 1136.0 Shipping weight(lb) 2658.0 Width (ins) 32.8 Operating weight(lb) 2771.0 Height (ins) 63.4 Refrigerant R410a Refrigerant charge ( lb) 100.0 DESIGN PERFORMANCE Capacity (tons) Input Power (kW) Performance (EER) Flow (gpm) IPLv Evaporator Condenser P.D. (ftHd) Tin ('F) Tout ff) P.D. (ftHd) Tin ('F) Tout ('F) 61.8 44.1 16.8 148.3 20.2 15.1 54.0 44.0 13.1 60.0 90.0 EVAPORATOR DATA CONDENSER DATA Design Flow m / P.D. ftHd 148.3 / 15.1 Desi n Flow m / P.D. ftHd 185.4 / 13.1 Fluid type Water Fluid type Water Percentage of fluid 100 Percentage of fluid 100 Number of passes 2 Number of passes 2 Fouling Factor F.fta.h/Btu 0.00010 Fouling factor F.fta.h/Btu 0.00025 Type Brazed Plate Tube material Cu Tube wall thickness ins Contact factory Tube wall thickness ins 0.025 Water volume al 3.2 Water volume al 13.6 Min flow m / P.D. ftHd 90.8 / 5.9 Min flow m / P.D. ftHd 113.415.2 Max flow m / P.D. ftHd 242.0 / 38.3 Max flow m / P.D.(ftHd PART LOAD PERFORMANCE AT AHRI STANDARD CONDITIONS P# %Mad request Capacity tons Total unit Input power W Pedonnance EER 1 100 60.6 46.6 15.6 2 75 45.4 29.0 18.8 3 50 - 30.3 17.1 21.3 4 25 15.1 8.5 21.3 SOUND DATA Sound pressure (at 1 meter) - octave band at center frequency (Without sound insulation) 63Hz 125Hz 2501­1z 500Hz 1000Hz 20001­1z 4000Hz 8000Hz - overall 64 57 62 75 65 69 65 56 75 Sound power - octave band at center ire uenc ithout sound insulation 63Hz 125Hz 250Hz 5001­1z 11000Hz 2000Hz 4000Hz 8000Hz Overall 72 65 70 83 73 1 77 74 1 64 -- 83 Octave band is non 'A' weighted and overall readings are 'A' weighted. Sound data rated in accordance with AHRI Standard-575. 0 2013 Daikin www.DaikinArolied.com �v Page 1 DAIKI ! �� r r 3 00 a• N 7 a 3 0 c o w LCYNG BUILDING ENVIRONMENTS TERMS AND CONDITIONS OF SALE - EQUIPMENT & PARTS LONG BUILDING TECHNOLOGIES, INC. is a manufacturers agent representing the various suppliers quoted in this proposal. Acceptance of this proposal is deemed to be acceptance of the terms and conditions set forth by the various suppliers represented herein. PRICE POLICY: Quotations are subject to acceptance within thirty (30) days from the date of quotation. TERMS: Terms of payment are subject at all times to the approval of LONG BUILDING TECHNOLOGIES, INC. and its suppliers' Credit Departments. CLAIMS: The responsibility of LONG BUILDING TECHNOLOGIES, INC. and their suppliers ceases upon delivery of goods in good order to the carrier. Claims for factory shortages will not be considered unless made in writing to LONG BUILDING TECHNOLOGIES, INC. within ten (10) days after receipt of the goods and accompanied by reference to our bill of lading and factory order numbers. As all goods are shipped at customers risk, any claims for damage or shortage in transit must be filed by customer against the transportation company. TAXES: The amount of any present or future taxes applicable to the product shall be added to the price contained herein and paid by the customer in the same manner and with the same effect as if originally added thereto. Taxes are not Included in the prices quoted on this proposal. CANCELLATIONS: Accepted orders are not subject to cancellation without LONG BUILDING TECHNOLOGIES, INC. and its suppliers being reimbursed for any and all expenses. DELAYS: LONG BUILDING TECHNOLOGIES, INC. and its suppliers shall not be liable for any delays caused by riots, strikes, fires, floods, lack'of transportation, accidents or any other contingency beyond Its control. PRODUCT CHANGES: In the interest of continuous product improvement, LONG BUILDING TECHNOLOGIES, INC. and its suppliers reserve the right to change specifications and/or design without incurring obligation. INSTALLATION: This proposal does not include installation labor, supplies or rigging unless otherwise noted in the proposal. RETURNED GOODS: Goods may not be returned except by permission of an authorized Officer of LONG BUILDING TECHNOLOGIES, INC. In Denver, Colorado and when so returned will be subject to a handling charge and transportation costs. Authorized return goods should be returned to suppliers as directed ti LONG BUILDING TECHNOLOGIES, INC. depending on point of origin. Return Shipments should not be directed to LONG BUILDING TECHNOLOGIES, INC.. WARRANTY: LONG BUILDING TECHNOLOGIES, INC. and Its suppliers warrant to the original purchaser that the products manufactured or supplied by them are free of defects in material and workmanship If property installed, maintained and used under normal conditions with competent supervision. The obligation of LONG BUILDING TECHNOLOGIES, INC. and its suppliers is limited to, at their option, repairing or replacing, F.O.B. point of manufacture or main office of LONG BUILDING TECHNOLOGIES, INc., any part or parts under this warranty which shall thus prove defective within one are shipment to the original purchaser (some suppliers may extend the warranty to one year after startup, or eighteen months after shipment whichever occurs first). LONG BUILDING TECHNOLOGIES, INc. and suppliers' examination shall disclose to their satisfaction the warranty status of parts claimed to be thus defective; warranty shall be valid provided such part or parts are returned to the suppliers manufacturing point or LONG BUILDING TECHNOLOGIES, INc. main office with transportation charges prepaid and provided that LONG BUILDING TECHNOLOGIES, INc. and its suppliers receive written notice Of such defect within 15 days of the failure of the product. The term "original purchaser', as used In this waranty shall mean that person to whom the product was originally supplied. ASSUME FOR THEM ANY OTHER WARRANTY OR LIABILrTY IN CONNECTION VY ITS SUPPLIERS MAKE NO WARRANTY WHATSOEVER REGARDING PARTS NO LS OR ACCESSORIES; SUCH rTEMS CARRY ONLY THE WARRANTY ISSUED BY IN CONCLUSION: All orders accepted by LONG BUILDING TECHNOLOGIES, INC. and its suppliers are with the express condition that the purchaser agrees with the terms and conditions appearing In this proposal. LONG BUILDING TECHNOLOGIES, INC. and its suppliers failure to obl'ect to the provisions contained In the customer's purchase order or other communications shall not be deemed a waiver of the terms and conditions hereof or acceptance of such provisions. No representations or guarantees other than those contained herein shall be binding upon LONG BUILDING TECHNOLOGIES, INC. and Its suppliers unless made In writing and signed by an Officer of LONG BUILDING TECHNOLOGIES, INC. and Its suppliers. Colorado Nevada Utah Wyoming