WORK ORDER FORM
PURSUANT TO AN AGREEMENT BETWEEN
THE CITY OF FORT COLLINS
AND
H&H
DATED: 7/10/2012
Work Order Number 1206019-4
Purchase Order Number:
Project Title: SMF FRII DRC
Commencement Date: 7/10/2012
Completion Date: 8/31/2012
Maximum Fee: (time and reimbursable direct costs): $5,964.37
Project Description: Hardware and Installation of Fiber Optic Equipment @ CHW
Scope of Services: Each site specific project requires a work order authorized by the project manager
and Purchasing agent for release of funds. Invoices to reflect specific work order number and PO
number.
Service Provider agrees to perform the services
identified above and on the attached forms in
accordance with the terms and conditions
contained herein and in the Work Order Services
Agreement between the parties. In the event of a
conflict between or ambiguity in the terms of the
Work Order Services Agreement and this work
order (including the attached forms) the Work
Order Services Agreement shall control.
The attached forms consisting of 1206019-4 are
hereby accepted and incorporated herein, by this
reference, and Notice to Proceed is hereby given.
IMSERVICESINC.DATA
DATA B VOIICE CABLING • PHONE SYSTEMS
J
PROPOSAL TO:
CITY OF FORT COLLINS
STREET:
PO BOX 580
CITY:
FORT COLLINS,CO 80522
CONTACT:
HILLARY KOONTZ
JOB NAME:
SMF FRII DRC
1310 Webster Ave.
Ft Collins, Co.80524
Tel: 970-482-6064
Fax:970-484-3252
PROPOSAL M 1206019-4 07/10/12
PROVIDE MATERIALS AND LABOR TO INSTALL, TEST AND DOCUMENT PER DESCRIPTION BELOW:
BACKBONE:
'INSTALL (1) ONE FL2-48RPNL-B TERM. ONLY PANEL IN THE DESIGNATED RELAY RACK IN THE PBX ROOM.
-INSTALL (4) FOUR FL2-6PSMLC ADAPTER PANELS IN THE FL2-48RPNL-B TERM ONLY PANEL IN THE PBX ROOM.
"INSTALL (1) ONE FEC-288 ON THE DESIGNATED WALL IN THE PBX ROOM.
'INSTALL (2) TWO FST-D-HS SPLICE TRAYS IN THE FEC-288 IN THE PBX ROOM.
Q "INSTALL (1) ONE MF242696-P-50F TRUNK BETWEEN THE FL2-48RPNL-B PANEL IN THE PBX ROOM TO THE FEC-288 IN PBX ROOM.
`INSTALL (1) ONE MF242696-P-100F TRUNK BETWEEN THE FEC-288 IN THE PBX ROOM AND THE EXISTING FL2000
TERM. SPLICE PANEL IN THE RELAY RACK IN THE PRPA ROOM.
INSTALL (2) TWO FL2-6PSMLC ADAPTER PANELS IN THE EXISTING FL2000 PANEL IN THE PRPA ROOM.
"SPLICE THE (2) TWO TRUNKS AND THE EXISTING 48 STD. SM FROM THE SERVER ROOM INTO THE FEC-2881N THE PBX ROOM.
1) SPLICE 24 STRANDS OF THE EXISTING 48 STD. SM FIBER FROM THE SERVER ROOM AT THE FEC-288 TO THE FIRST 24 STDS. OF
THE MF242696-P-50F TRUNK FROM THE FL2-48RPNL-B TERM ONLY PANEL IN THE RELAY RACK IN THE PBX ROOM.
2) SPLICE 24 SRANDS OF THE 48 STD. MF242696-P-100F TRUNK FROM THE PRPA ROOM TO THE SECOND 24 STDS. OF THE
MF242696-P-50F CABLE FROM THE FL2-48RPNL-B TERM ONLY PANEL IN THE RELAY RACK IN THE PBX ROOM.
`COIL ALL UNUSED FIBERS IN THE FEC AND THE TERM. ONLY PANEL FOR FUTURE USE.
'LEAVE ALL EXCESS TRUNK CABLE COILED ABOVE CEILING IN A SERVICE LOOP. (DO NOT CUT ANY MORE OF THE TRUNK
CABLE THAN WHAT IS NEEDED.) THESE SERVICE LOOPS WILL BE MAINTAINED FOR FUTURE MOVES IF NEEDED.
TESTING AND DOCUMENTATION:
`INCLUDES LABELING WITH MACHINE GENERATED WHITE LABELS WITH BLACK LETTERING.
'LABELING SCHEME: PER CITY STANDARDS.
'INCLUDES TESTING WITH LEVEL III TESTERS.
"INCLUDES (1) ONE COPY OF TEST REPORTS ON CD.
'EXCLUDES (1) ONE COPY OF AUTOCAD AS -BUILT ON CD.
7310 Webster Ave.
& Ft. Collins, Co.80524
SERVICESiHc. Tel: 970-482-6064
DATA H VOICE CABLING •PHONE SYSTEMS Fax: 970-484-3252
PROPOSALTO:
CITY OF FORT COLLINS
STREET:
PO BOX 580
CITY:
FORT COLLINS,CO 80522
CONTACT:
HILLARY KOONTZ
JOB NAME:
SMF FRII DRC
PROPOSAL #_ _
1206019-4 07/10/12
PROVIDE MATERIALS AND LABOR TO INSTALL, TEST AND DOCUMENT PER DESCRIPTION BELOW
GENERAL:
*H&H TECHNICIANS ARE INDUSTRY AND MANUFACTURER CERTIFIED.
*H&H DATA SERVICE'S RCDD AND A PROJECT MANAGER WILL OVERSEE THE INSTALLATION.
*INSTALLATION WILL BE PER ANSI/EIA/TIA STANDARDS AND LOCAL CODES AND ORDINANCES.
*INSTALLATION OF ALL WORK TO BE COMPLETED DURING STANDARD BUSINESS HOURS.
*INCLUDES MANUFACTURER'S WARRANTY ON MATERIALS AND ONE-YEAR WARRANTY ON WORKMANSHIP.
*EXCLUDES TAX.
*EXCLUDES CROSS -CONNECTS TO SERVICES AND CUSTOMER EQUIPMENT.
*EXCLUDES CONDUIT, J- BOXES IN WALLS AND ABOVE CEILINGS AND SLEEVES BETWEEN FLOORS AND THROUGH WALLS.
QTY UN
MFG
PART#
DESCRIPTION
EXTENSION
1 EA
ADC
FL2-48RPNL-B
FL2000 48 EMPTY FIBER ENCLOSURE
$217.65
6 EA
ADC
FL2-6PSMLC
6PAK PLUG-IN SINGLEMODE DUPLEX ADAPTER LOADED
$444.71
1 EA
ADC
FEC-288
FIBER ENTRANCE CABINET / 288 SPLICE CAPACITY
$1,630.12
2 EA
ADC
FST-D-HS
24 SPLICE TRAY, CAPACITY DUAL POSITION HEAT SHRINK FUSION
$102.94
1 EA
MCC
MF242696-P-50F
LC SM 48STR PVC 50FT TRUNK
$705.88
1 EA
MCC
MF242696-P-100F
LC SM 48STR PVC 100FT TRUNK
$1,138.82
48 LOT
N/A
N/A
SPLICE (48) STD. AT FEC IN PBX ROOM
$0.00
48 EA
CORNING
2806031-01
SPLICE SLEEVE PROTECTORS
$41.51
1 LOT
N/A
N/A
MISC. CONSUMABLES
$100.00
10 FT
N/A
N/A
#6 THHN GREEN WIRE, GROUNDING
$6.80
2 EA
ILSCO
CLND-6-14-58
GROUNDING -SURE CRIMP
$9.08
1 EA
RINO-TAPE
18443
LABELING TAPE
$14.86
1 LOT
N/A
N/A
TESTING - EXCLUDES PRINTED TEST REPORTS
$0.00
0 EA
N/A
N/A
$0.00
„,.y_` ,,.,;, "t: )h?'° :, 1310 Webster Ave.
DATA f 1
'�J`j=1`' SERVICES rT: - I Ft Collins, Co.60524
wC. Tel: 970-482-6064
;ATA 6 VOICE CABLING • PHONE SYSTEMS Fax: 970-484-3262
PROPOSAL TO: CITY OF FORT COLLINS
STREET: PO BOX 580
CITY:
FORT COLLINS,CO 80522
CONTACT:
HILLARY KOONTZ
JOB NAME:
SMF FRII DRC
PROPOSAL M
1206019-4 07/10/12
PROVIDE MATERIALS AND LABOR TO INSTALL, TEST AND DOCUMENT PER DESCRIPTION BELOW
Proposal Accepted By:
Printed Name:
Date:
*H&H proposal number shall be on all Job related documents.
Note: This quote is valid for 30 days.
50% of materials will be billed upon contract signing.
MATERIAL
$4,412.37
LABOR
$1,552.00
TAX (0%)
$0.00
TOTAL
$6,964.37