Loading...
HomeMy WebLinkAboutWORK ORDER - PURCHASE ORDER - 9122011CjlzZ61� EXHIBIT "A" WORK ORDER FORM PURSUANT TO AN AGREEMENT BETWEEN THE CITY OF FORT COLLINS AND E CUBE, INC. DATED: October 1, 2009 Work Order Number: CM-01-2012 Purchase order Number: Project Title: Utilities Addition, Remodel HVAC and Lighting Upgrades (USCCapital ProjectLnprovements) Commencement Date: April02,2012 Completion Date: August15,2012 Maximum Fee (-time and reimbursable direct costs): S82,775.00 Project Description: Dssign and phased construction for Light& Power Area addition remodel various areas HVAC study, and probable HVAC & lighting upgrades to entire building at 700 Wood Street Scope of Services: Retro-commissioning as per five page proposal tom 9Cube dated March 19 2012 ACCEPTANCE S. Seefeld USER 1/9— Service Provider agrees to perform The attached forms consisting the services identified above and on of fide �5) pages are hereby the attached forms in accordance, accepted and incorporated with_tTxe_terms—and--cond-iLioa"s herein—by--this—refexenae--and— -- contained herein and in the services Notice to Proceed is hereby Agreement between the parties. In given - the event of a conflict between or ambiguity in the terms of the Services Agreement and this work order (including the attached forms) the Services Agreement shall control. SERVICE PROV 'DER By: Date: CC: Purchasing CITY 0 F RT COLL By: Date: i Director of Purchasing and Rlsk Management over " I $60,000. J SCube, Inc. Energy • Efficiency • Enuironment • Technical Consulting March 19, 2012 - Steve Seefeld, CCCA •.r�It6�iGUS(tyw .r: f'2 3, 2W ,ju; �? � City of Fort Collins Operations Services 117 N. Mason PO Box 580 Fort Collins, Colorado 80522-0580 Re: Fort Collins Utility Service Center Retro-Commissioning - Fee Proposal Steve: This letter represents our proposal to the City of Fort Collins for Retro-Commissioning on the Utility Service Center Building located at 700 Wood St. Ft. Collins CO. This proposal was tailored to meet the city's needs with direct input from Steve Seefeld, Gary Schroeder and Dennis Dutton. Equtoment/Systems to be commissioned (From the HVAC report dated 8 Dec 20111: • 11 RTU/AHUs 5 Condensing Units 7 Boilers and distribution system — baseboard, RH coils, RTU/AHU coils. Boiler Pumps — and distribution pumps TerminaWAV units (100%) Building Automation System (JCI) 10 Gas Unit Heaters 1 Furnace Unit • 2 CRAC units 10 Exhaust Fans Capital Improvements to be examined: • New Central Plant, New DDC system, Right sizing equipment, IDEC systems, Geothermal Heat - pump system using lake water as heat sink Schedule for completion of the oroiect: This year Level of Effort by Phase The following table represents an hourly breakdown for the scope of work as defined in the RFP and refined following our February 10, 2012 meetings with Steve Seefeld and Gary Schroeder. 598.8 Ft. Collins Utility Service Center Retro-Commissionin Proposal i�TaskCode`S yv.Yi..Y; .t�%r*'try''i'.,�1.;'-�je` tTask9a• :. % 7'_-.��3t:°' : `!§t' .c.�r(�i I.V Hour�"s r i Project Management 1 Plannino and Manaciement 36 2 Client communication and coordination meetings 20 3 RCx Schedule, Develop and Maintain 5 4 Administrative 4 sd+. .�:��t'. 3".q---.a.._a-•c-w�.,�.r l r�emrt.: y 1 5i'1 SfNr K ,13PIa nin (Phase w.s•;.,.,._ ,u`- ` �?r,:ai...«. .�i�"h ac:s�... k'n>r't3.S..., M '5 100 a Initial Site Survey and Interview 40 E Cube, Inc. Boulder, Colorado (303)443-2610 FAX(303)443-3704 (www.ecube.coml Chicago, Illinois (312)441-9610 FAX(312)141-9611 City of Fort Collins Utility Service Center Retro-Commissioning ibfarch 19, 2012 Page 2 101 I b) Documentation Review: As-Builts, Warranties, Maintenance Schedules and Records TAB Reports, Cx Reports 32 102 c Develop Utility Bill Benchmarkin Plan Provided by the City) 0 103 d) Generate Energy Use Index (EUI) and Energy Star Benchmark for Baseline Condition Provided by the City) 0 104 a Generate Pro'ecl Issues Log FONs) 20 105 Generate list of Potential Energy Conservation Measures ECMs 44 106 Developand Submit RCx PlanningReport 107 Identify RCx Ob ectives 8 108 ii Determine Prelimina' ECMs 16 109 iii Develop Investigation Aroach %•" i 110 1 Generate Sample Pt -Pt and Functional Testing App III a Produce Sample Pt -Pt and Functional Testing Forms 24 112 b Provide Existing Equipment Inventory and Soo 8 113 c Determine Equipment that Requires a Calibration Check 4 114 (d) Determine the Role of Buildings Operations Staff During Testing Along with Impacts to Building Occupants 8 115 2 Present Test and Balance Assessment Approach 0 116 3 Determine Plan for Post Corrective M & V 0 r Lo' t231n'v`ei3tl aeon P.liase ,t'�`,k x,r, 'i-`, z ,.a e;zT �tfi,F M= 200 a Implement Diagnostic Monitoring Data Logging) Plan 20 201 bt Conduct Pt -Pt and Functional TeOinn 120 202 c Execute Test and Balance Assessment Survey 0 203 d Perform Equipment Calibration Tests 40 204 a Identi any Code or Health and Safety Deficiencies or Concerns 8 205 Update the FONs and List of Potential ECMs 24 206 Retrieve and Anal ze Data Logging Data 60 207 h Perform Energy Analysis of Potential ECMs 208 i) Utilize Results of Data Trending, Benchmarking Results, and Field Observations to Determine Baseline Energy Performance 0 209 ii) Analyze Potential ECMs for Energy Savings Potential and Economic Benefit 0 210 iii Anal ze Synergistic Effects of Combinations of ECMs 16 211 i Develop Investigation Report *, 212 i Present Trend Data Assessment Results 8 213 ii Present Results of All Field Testing and Surveys '°:'?+:' %.'i{?•4 214 1 Completed Functional Testing and Pt -Pt Procedures 24 215 2 TAB Assessment Survey Results 0 216 3 Equipment Calibration Results 4 217 4 Current Project Issues Log FONs) 4 218 iii Present Results of Energy Analysis 0 219 iv) Present a Prioritized list of Recommended ECMs with Economic and Energy Savings Estimates, Associated Implementation Cost and any Applicable Incentives 8 220 Ca ital improvements Recommendations and ROI see list below 45 300 a) Implement repairs and improvements that have no cost or have less than 1 year payback along with any easily made Maintenance corrections. TBD 301 b Implement Measurement and Verification Plan and record results TBD 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) -143 -3 704 113 S. Clinton, 650 • Chicago, IL 60005 • (312) 4419610 • Fax (312) 441-9611 Cih, of Fort Collins Utility Service Center Retm-Commissioning March 19. 2012 Page 3 302 c Fine-tune improvements if needed T8D 303 d Revise estimated energy savings calculations TRD 4 Project HandoH (Operational) Phase - 400 a) Prepare and submit final report with master list of improvements made and improvements suggested TBD 401 b) Develop guidelines and recommendation for incorporating energy accounting and tracking systems. TBD Total Hours 650 NOTE: Upon completion of Phases 1 & 2 (Planning and Investigation), the necessity of continuing with Phases 3 and 4, (Implementation and Handoff) will be determined and priced if necessary in light of the best interest of the City. (Per discussion with Gary Schroeder) This proposed fee is based upon E Cube's interpretation of the projects needs and our estimation of the required level of effort in man hours and trips to the project site. This is all based on our experience with adding value to projects of this type. Should you have any questions or concerns regarding our interpretation of the desired scope of services, please do not hesitate to contact us to discuss these matters. Contributors C.ntnb.fttm % 201ZRates ,:Principals, Project __________________________________ 5%n____,___ 173 Senior Associates_ Senior Project Managers, VPs 8 % $135 :Associates, Senior Engineers, Project Managers.___.______ .____ 25% „ $127 .: Staff Epgineers_&Analyst_Level ll__........................ 60(........ 121 Staff EngipeersBAnalyst,Levell............................... .._........ ________ 5715 Senior Field Technicians ................................................................................................. $112 Field Technicians $78 Project Resource Manager ........................................ ..„_.. 2% 54 Sum of Effort 100% 7012 AVERAGE RATE S124.67/hour DIRECT PROJECT EXPENSES $1740.00 PROFESSIONAL SERVICES FEE E Cube is pleased to provide the following fee for Commissioning Services in supporting the City of Fort Collins with commissioning services for the Utility Service Center building. Proposed Fee for the Utility Service Center Building FIXED LUMP SUM: $82,775.00 FI .HTY-TWO THOUSAND c V N H tNDR D SEVENTY FIVE DOLLARS Fee does not include commissioning of the new 20,000 sq R, 2story, addition 1900 Folsom. Suite 109. Boulder, CO 811302 . (303) 443-2610 . Fax (303) 443-3704 118 S. Clinton, H00 . Chicago, IL 60005 . (312) ,141-9610 . Fax (312) 441 961 1 City of Fort Collins Utility Service Center Retro-Commissioning iblarch 19. 2012 Page=1 Fee does not include commissioning of the new 20,000 sq ft, 2-story addition Expenses E Cube, Inc. makes a point of aggressively managing reimbursable expenses so that project costs may be used for more productive purposes such as additional time on -site reviewing systems. Nonetheless, reasonable and normal reimbursable expenses including long distance calls, printing, reproduction, shipping, equipment rental, and mileage expenses will be billed at their direct cost with no markup, and are included in the proposal amount presented in the fixed fee amount. Assumptions and Clarifications I. This quotation is based on the project documents presented to us by the Owner. 2. This quotation is based on the allocation of hours as shown in the detailed Level of Effort Table above. Flours may be moved between tasks as needed and appropriate. 3. This quotation is based on all work, being performed on straight time, i.e., during normal weekday working hours. 4. In terms of altered schedules, two changes in schedule that incur no added cost as well as two that will add cost, are considered here as follows: • No added cost: • if the schedule shifts by one or more weeks but remains the same overall length • if the schedule lengthens but the commissioning team is still on -site for the same total amount of time • Added cost: • if the schedule lengthens and, as a result, there are delays but the commissioning team is still needed on -site due to the lengthening schedule • if the schedule is compressed and, as a result, the commissioning team is required to work overtime to meet the new schedule. Note that from a practical standpoint, this compression is probably limited to approximately 3/4 of the allowed time for a given sequence of tasks. Overtime will be billed at an agreed upon differential i. An addition of equipment or an increase in complexity to the scope shall result in an incremental increase in the commissioning costs included. 6. The contract amount herein is contingent upon no -cost access (to E3) of the "front end" software for the controls system for remote monitoring. In addition, appropriate manuals, proper control system passwords, and access levels, to the projects will be needed for complete monitoring and commissioning shall he provided. Web -based access is acceptable. 7. Owner will arrange or provide facilities for all scheduled meetings. S. Systems that turn out to not be ready for successfid completion of functional procedures, after being represented as ready, will be subject to additional incurred costs (hourly rate(s), travel and other expenses) if additional work is required. These situations will be carefully documented and reported to the Owner for authorization to proceed. 9. Once deficiencies or problems are noted and reported, E Cube will be available for one additional effort to establish that these items have been corrected. E Cube's scope (foes not include further efforts should problems remain unresolved: and, all work beyond the scope of this letter and scope description will be an added charge. 10. Only the equipment and/or DEC points installed Under the above -mentioned "systems to commission' will be commissioned. 11. Once deficiencies or problems are noted and reported, E Cube is not responsible to ensure that [lie items are corrected. and all work beyond the scope of this letter and scope description will be an added charge. 12. E3 will not authorize and/or approve any chan_aes in construction schedule, cost (including change -orders), or contractual requirements. 1900 Folsom, Suite 109 • Boulder. CO 30301_ • (303) 443-2610 • Fax (303) 443-3704 118 S. Clinton, #650 • Chicago, IL 60005 • (312) 441-9610 • Fax (312) 441-9611 City of Fort Collins utility Service Center Retro-Contntissioning March 19, 2012 Page a 13. E3 is not responsible for any construction means and methods, site safety, or site security. 14. All project communication and instruction will be channeled through Ou'ner/Construction Team. It will be necessary that Owner/Construction Team will coordinate site visit to"istics and will coordinate with the appropriate parties involved in functional procedures. In addition, E Cube, Inc. is not responsible for schedule slips due to incomplete systems or unforeseen problems or delays. Date Consultant Authorized Agent Title Signatuatb- Approved and Accepted by: Date Client Authorized Agent Title Signature Please review this at your convenience and let us knoW'if there are any questions or other matters to discuss. Our entire team continues to look forward to more work with you and the City of Fort Collins. C:\PROJECl1598.8 (Utility Svs C(r_Cx)tAdmin\598.8 RCx fee_prop.doc 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 118 S. Clinton, ="650 • Chicago, If- 60005 • (312) 44 1-96 10 • Fax (312) 441-9611