HomeMy WebLinkAboutRESPONSE - BID - 7282 LP TRANSFORMERS 25KVA & 100KVA PADMOUNTED SINGLE PHASEFIRM NAMEWa, bja4�1,+)Jq CITY OF FORT COLLINS BID PROPOSAL BID NO. 7282 LP Transformers, 25kVA & 100kVA, Padmounted, Single Phase BID DATE: 3:00 p.m. (Our clock) October 7, 2011 WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR LP Transformers, 25kVA & 100kVA, Padmounted, Single Phase, PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS. QUANTITY: DESCRIPTION: 30 Ea. TRANSFORMER, 25 KVA PAD -MOUNTED, ANSI TYPE 1, c COMPARTMENTAL -TYPE, SINGLE PHASE DISTRIBUTION WITH SEPARABLE INSULATED LOAD BREAK HIGH -VOLTAGE CONNECTORS. HIGH VOLTAGE RATING: 13200 GRDY/7620. LOW VOLTAGE RATING: 240/120. SERIAL NUMBER 130 TO BE IN ACCORDANCE WITH SPECIFICATION #368-120-130, REVISION FF. PLEASE COMPLETE THE ATTACHED EXCEL SPREAD SHEET FOR BID SUBMITTAL. IF YOU ELECT TO PASSWORD PROTECT YOUR BID, PLEASE NOTE THAT PASSWORD BELOW. 'Any surcharges or additional costs shall be noted & included in bid submittal. The transformers being bid meet or exceed the specifications. Yes No. If not, please list exceptions, (specifying paragraph reference number) on a separate sheet of paper and attach to your bid. Escalation is , is not applicable for the transformers bid. If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof. Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city. Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid. REV. SYM: FF TABLE OF CONTENTS PREVIOUS REVISION DESCRIPTIONS ON FILE..........................................................................................................................2 ISCOPE 2 APPLICABLE DOCUMENTS............................................................................................................................................................4 2.1 ANSI C57.12.00 - DISTRIBUTION, POWER, AND REGULATING TRANSFORMERS, AND SHUNT REACTORS, GENERAL REQUIREMENTS FOR.................................................................................. .............................................. ......................................................................... 4 2.2 ANSI C57.12.25 - PAD MOUNTED, COMPARTMENTAL -TYPE, SINGLE-PHASE, DISTRIBUTION TRANSFORMERS WITH SEPARABLE H-V CONNECTORS, STANDARD REQUIREMENTS FOR..........!............................................................................................................................4 2.3 ANSI C57.12.28 - SWITCHGEAR AND TRANSFORMERS - PAD -MOUNTED EQUIPMENT -ENCLOSURE INTEGRITY...............................4 2.4 ANSI C57.12.70 - TERMINAL MARKINGS AND CONNECTIONS FOR DISTRIBUTION AND POWER TRANSFORMERS...............................4 2.5 ANSI C57.12.80 - TERMINOLOGY FOR POWER AND DISTRIBUTION TRANSFORMERS........................................................................4 2.6 ANSI C57.12.90 - DISTRIBUTION, POWER, AND REGULATING TRANSFORMERS, AND SHUNT REACTORS, TEST CODE FOR.................4 2.7 IEEE C57.91 - GUIDE FOR LOADING MINERAL -OIL -IMMERSED OVERHEAD AND PAD -MOUNTED DISTRIBUTION TRANSFORMERS RATED 500 KVA AND LESS WITH 650C OR 550C AVERAGE WINDING RISE.......................................................................................... 4 3 REQUIREMENTS................................................................................................................................................................................4 3.1 GENERAL REQUIREMENTS FOR DESIGN...............................................................................................................................4 3.2 SPECIFIC DESIGN REQUIREMENTS..........................................................................................................................................5 4 QUALITY ASSURANCE....................................................................................................................................................................9 4.1 GENERAL ........................... 4.2 TEST CONDITIONS........... 4.3 NOT USED ............ ................. 4A TESTS .................................. .............9 5 PREPARATION FOR DELIVERY....................................................................................................................................................9 6 DEFINITIONS AND ABBREVIATIONS........................................................................................................................................10 APPENDIX A -TRANSFORMER STOCK NUMBER CODING...................................................................................................I I APPENDIX B-DIMENSIONAL DRAWINGS............................................................. ».................................................................. 12 PADDIMENSIONS ..............................................................................................................................................................................14 APPENDIX C - APPROVED MANUFACTURERS......................................................................................................................... 15 TRANSFORMER LOSS EVALUATION -AVERAGE LOSSES.................................................................................................... 16 INDIVIDUAL TRANSFORMER LOSS EVALUATION.................................................................................................................17 3 368-120 REV. SYM: FF SPECIFICATION FOR PAD -MOUNTED COMPARTMENTAL -TYPE SINGLE-PHASE DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED LOAD BREAK HIGH -VOLTAGE CONNECTORS 1 SCOPE This Specification establishes the minimum electrical requirements and mechanical features of single phase, 60 HZ, mineral oil immersed, self -cooled, pad -mounted, compartmental -type distribution transformers rated 250 KVA and smaller, high voltage 13,200 Grd Y/7620 volts, with separable insulated load break high voltage connectors. These transformers are used for step down purposes from an underground primary cable supply. This standard generally conforms with ANSI requirements for pad -mounted compartmental -type, self -cooled, single- phase, distribution transformers, C57.12.25. 2 APPLICABLE DOCUMENTS The following documents of the issue shown form a part of this Specification to the extent specified herein. In those cases when the document is note dated, the latest issue in effect on the date of invitation for bids shall form a part of this Specification. 2.1 ANSI C57.12.00 - Distribution, power, and regulating transformers, and shunt reactors, general requirements for. 2.2 ANSI C57.12.25 - Pad mounted, compartmental -type, single-phase, distribution transformers with separable H-V connectors, standard requirements for. 2.3 ANSI C57.12.28 - Switchgear and Transformers - Pad -Mounted Equipment -Enclosure Integrity. 2.4 ANSI C57.12.70 - Terminal markings and connections for distribution and power transformers. 2.5 ANSI C57.12.80 - Terminology for power and distribution transformers. 2.6 ANSI C57.12.90 - Distribution, power, and regulating transformers, and shunt reactors, test code for. 2.7 IEEE C57.91 - Guide for Loading Mineral -Oil -Immersed Overhead and Pad -Mounted Distribution Transformers Rated 500IMA and Less with 65°C or 55°C Average Winding Rise. 3 REQUIREMENTS 3.1 GENERAL REQUIREMENTS FOR DESIGN 3.1.1 BASIC DESIGN STANDARDS Transformers purchased under these Specifications shall be new and, unless otherwise specified, meet the requirements of the applicable ANSI Standards and the modifications and additions given in the subsequent paragraphs. In case of conflict, the requirements of the following documents shall apply in the priority shown: a) This Specification b) Applicable ANSI Standards Approved manufacturers are listed in Appendix C. 4 368-120 REV. SYM: FF 3.1.2 KILOVOLT -AMPERE TEMPERATURE RATINGS Kilovolt -ampere ratings are continuous and are based on not exceeding either a 65°C average winding temperature or an 80°C hot spot temperature rise. The temperature rise of the insulating oil shall not exceed 65°C when measured near the top of the tank. The temperature rise is based on an altitude of 3,300 feet. The transformers shall be designed for overloads based on IEEE C57.91. 3.1.3 GENERAL CONSTRUCTION 3.1.3.1 The pad -mounted compartmental -type transformers shall consist of the transformer tank and high -and -low - voltage cable terminating compartment constructed in accordance with ANSI C57.12.25 and ANSI C57.12.28. The terminating compartment and tank shall be assembled as an integral unit, tamperproof and weatherproof for mounting on a pad. There shall be no exposed screws, bolls, or other fastening devices which are externally removable. The cover shall be welded construction. There shall be no opening through which foreign objects such as sticks, rods, or wires might be inserted to contact live parts. Suitable means for padlocking the compartment door(s) shall be provided. 3.1.3.2 The high- and low -voltage compartment shall be located side by side on one side of the transformer tank. When facing the compartment, the low -voltage side shall be on the right. 3.1.3.3 Construction of the unit shall be such that it can be lifted, skidded, and slid into place on the mounting pad without disturbing the entrance cables. 3.1.3.4An undercoating over the regular finish or an equivalent treatment shall be applied to all surfaces that are in contact with the pad to minimize corrosion. 3.1.3.5 Minimum dimensions for Type 1 transformers shall be as shown in Figure 1, Appendix B. Minimum dimensions for Type 2 transformers shall be as shown in Figure 2, Appendix B. 3.2 SPECIFIC DESIGN REQUIREMENTS 3.2.1 FUNCTIONAL DESCRIPTION The transformer shall be a single'phase, pad mounted, loop feed -safe break, "dead -front" type for use on a 13.8 kV grounded "Y" distribution system. 3.2.2 DESIGN AND CONSTRUCTION j 3.2.2.1 RATING The transformer shall be rated as follows: a) High Voltage 13,200 Grd. YI7620 volts b) Low Voltage 2401120 i c) Taps Two - 21/.% FC above and below normal d) Polarity Additive e) Capacity, Impedance values, and fusing for transformers in this specification shall conform to Table 1: 5 368-120 REV. SYM: FF Table 1 — Transformer Capacity. Impedance and Fuse Selection Stock kVA Min. ' Max. Bay-0-Net Current Limiting Fuse(s) Number Capacity Impedance Impedance Fuse 368-120-130 25 1.77% 2.16% 10 Amp ELSP 354403OM61 M (30 A) 4000353C08 368-120-150 50 1.77% 2-16% 15 Amp ELSP 3543640M81M(40 A) 4000353C08 368-120-155 50 1.77% 2.16% 15 Amp ELSP 3543040M61M (40 A) 4000353C08 368-120-170 100 1.95% 238% 25 Amp ELSP 3543080M71 M(80 A) 4000353C10 368-120-180 167 2.28% 2.79% 40 Amp ELSP 3543125M71 M(125 A) 4000353C72 368-120-190 250 5.75% 6.61% 65 Amp ELSP 3543125M71M(125 A) 4000353C74 'The BAY-0-NET fuse shall be located in the high voltage side of the compartment. 3.2.2.2 INSULATION LEVEL 3.2.2.2.1 The basic impulse insulation level (BIL) of completely assembled high -voltage and low -voltage terminals shall be 95 kV and 30 kV respectively. 3.2.2.2.2 Dielectric test levels shall be in accordance with the distribution levels in Section 4 of ANSI C57.12.00. 3.2.2.3 HIGH -VOLTAGE TAPS A no-load tap changer with external operating handle shall provide two - 2%% full capacity taps above and below normal. The tap changer operating handle shall be located within the high -voltage terminal side of the terminal compartment. 3.2.2.4 NOT USED 3.2.2.5 BUSHING WELLS AND TERMINALS 3.2.2.5.1 The number, location, and arrangement of bushing wells, terminals and parking stands shall be as shown in Fig. 1 or Fig. 2 in Appendix B. All low -voltage bushings and high -voltage wells shall be externally clamped and shall have leads of sufficient length to allow them to be changed without removing the cover. Welded bushings and wells are expressly prohibited. 3.2.2.6.2 High -voltage terminals shall be universal flowerpot bushing wells in accordance wlth Figure 3 of ANSI/IEEE 385-1985. Two wells shall be provided and shall be connected in a feed -through configuration. Loadbreak bushing inserts in accordance with Figure 5 of ANSI/IEEE 386-1985 will be owner furnished. 3.2.2.5.3 Low-vohage line and neutral terminals shall be sized as shown in Table 2 in accordance with ANSI C57.12.25. Bushing arrangement and spacing shall be shown in Fig. 1 or Fig. 2 in Appendix B. Table 2 — Low Voltame Terminal Sizes Stock Number. kVA Capacity Low volts a Terminal Size 368-120-130 25 5/8" x 11" UNC-2A copper studs 368-120-150 50 518" x 11" UNC-2A copper studs 368-120-155 50 5/8" x 11" UNC-2A copper studs 368-120-170 100 1"x 14" UNC-2A copper studs 368-120-180 167 1" x 14" UNC - 2A copper studs 368-120-190 250 1 %" x 12 UNF - 2A copper studs. 3.2.2.5.4 The low -voltage Xz bushing shall be a fully insulated bushing. A ground pad shall be provided on the outer surface of the tank'and an external removable cooper ground strap shall be provided and connected between the lbw -voltage Xz bushing and the ground pad. 3.2.2.5.5 The high -voltage neutral shall be securely grounded internally. 6 368-120 REV. SYM: FF 3.2.2.6 ACCESSORY CABINET 3.2.2.6.1 The accessory cabinet shall consist of a compartment containing high- and low -voltage bushings constructed in accordance with applicable ANSI specifications, including ANSI C57.12.28. Dimensions shall be in accordance with Fig. 1 of this specification. 3.2.2.6.2 Cabinet doors shall be hinged, removable, lockable, and of sufficient sae to provide adequate working space when removed or open. Unlocking the padlock shall permit access to both the high- and low - voltage terminations. Stainless steel hinge pins shall be provided. 3.2.2.7ACCESSORY EQUIPMENT Accessory equipment shall be provided in accordance with the following details: 3.2.2.7.1 Deleted 3.2.2.7.2 The transformer base shall be arranged for rolling in two directions: Parallel to and at right angles to the center line of the high -voltage bushings. 3.2.2.7.3 Lifting lugs or bosses for screw -in lift bolts shall be provided. These lugs or bosses shall be adequate strength and size and arranged on the tank to provide a suitable balanced lift for the completely assembled unit. 3.2.2.7.4 The base of the assembly shall be provided with suitable means for mounting the unit on the pad. An internal flange shall be provided at the base of the accessory compartment to provide means for mounting the unit on the pad. (Fig. land Figure 2, Appendix B). 3.2.2.7.5 Terminal designations are shown in Figure 1 and Figure 2, Appendix B. The identification of terminal connections shall be shown on the instruction nameplate. Instruction nameplate shall be located in the low -voltage side and shall be readable with cables in place. Where the nameplate is mounted on a removable part, the manufacturer's name and transformer serial number shall be permanently affixed to a non -removable part. Instruction nameplate shall contain the information specified in 5.12 of ANSI C57.12.00-1987, Nameplate A. Also, on the nameplate, or label affixed near it, the manufacturer shall indicate that the dielectric fluid contains less than 1 ppm; PCB. 3.2.2.7.6 A suitable marking inside of the tank shall indicate the correct oil level at 25°C 3.2.2.7.7 An automatic pressure relief device shall be located within the compartment. This device shall meet the following requirements: I • Y4" NPT or larger male Inlet Port. • Exposed parts of weather and corrosion resistant materials. • Non -deteriorating gasket and o-ring material. • Manual pull ring able to withstand 25 pound force minimum. • Body able to withstand 100 pound shear force minimum. • Bug shield. • Cracking pressure of 10 t 2 psig. • Resealing pressure of 8 t 2 psig. • Zero leak rate from 8 t 2 psig to -8 psig. • Minimum flow rate of 35 SCFM at 15 psig. 3.2.2.7.8 An RTE BAY-O-NET current sensing fuse and internally mounted partial range current limiting fuse shall be furnished as shown in Table 1. 3.2.2.8O1L PRESERVATION Transformers shall be of sealed -tank construction. Sealed -tank construction is that which seals the interior of the tank from the atmosphere, and in which the gas plus the oil volume remains constant. The transformer will remain effectively sealed for a top -oil temperature range of -5°C to 105°C. 3.2.2.9TANKS The tank shall be domed or sloped to shed water. The tank shall be of sufficient strength to support a minimum of 500 lbs. vertical load. Construction of the tank shall be in accordance with ANSI C57.12.25- 1981, paragraphs 6.1 and 6.6. 7 368-120 REV. SYNI: FF 3.2.2.9.1 The cover shall be welded construction. 3.2.2.9.2 Tank grounding provision shall consist of two steel pads, each with Y2 inch - 13 NC tapped hole, 7/16 inch deep. 3.2.2.9.3 These ground pads shall be welded on the transformer base or on the tank wall near the base, one in the high -voltage side and one in the low -voltage side. In cases where the transformer tank and compartments are separate, provisions shall be made for electrically connecting them. 3.2.2.9.4 Locking bolts shall be pentahead. 3.2.2.10 COMPONENTS FOR LOOPED PRIMARY The minimum current -carrying capability of components for the looped primary cable system shall be 200 amperes (continuous) and 10,000 amperes symmetrical (momentary). 3.2.2.11 AUDIBLE SOUND LEVEL The audible sound level shall be in accordance with NEMA Standard TR1-1980. 3.2.2.12 BASE PLAN The base plan of a completely assembled unit shall be such that it can be installed on a pad of the dimensions shown in Fig. 1 B. 3.2.2.13 PAINT EEI "Finishing Guidelines" specification shall apply. Finish coat shall be Munsell Green, glossy. 3.2.2.14 LOSSES The total losses of transformer shall be the sum of the excitation losses and the load losses (I=R losses) Load loss tests shall be performed and reported on all units regardless of whether or not a record of such tests is available on duplicate units. Loss evaluations and loss costs will be based on the values shown in the "Special Conditions and Supplemental Instruction to Bidders." Transformers will be evaluated on excitation losses and I'R losses at the specified rates. If tested losses exceed quote losses but are within the tolerances of Table 18, ANSI C57.12.00-1987, the additional cost incurred from the differential of losses will be calculated using the following equation and the above specified rates and will be deducted from the original Purchase Order or back charged to the manufacturer. In Table 18 and the following equation "Units" shall mean 'Transformers of the same size and design on one order ". Excess loss $ _ [No. of units] [(No Load Loss Evaluation $) (Avg. No Load Losses - Quoted No Load Losses) + (Load Loss Evaluation $) (Avg. Load Losses - Quoted Load Losses)]. If this equation results in a negative number, no credit will be given the Supplier. If any unit or units exceed the tolerances of Table 18, ANSI C57.12.00-1987, that unit or units shall not be shipped without express permission from the City. If accepted, the deduction for excess losses will be based on the following equation: Excess loss $ _ (No Load Loss Evaluation $) (No Load Losses - Quoted No Load Losses) But Not Less Than Zero + (Load Loss Evaluation $) (Load Losses - Quoted Losses) But Not Less Than Zero. 3.2.2.15 SAFETY LABELS NEMA 1260 Safety Labels shall not be applied by the manufacturer: Purchaser will apply customer warning labels after delivery. 8 368-120 REV. SYM: FF 4 QUALITY ASSURANCE 4.1 GENERAL 4.1.1 RESPONSIBILITY FOR INSPECTION Unless otherwise specified, the vendor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified, the vendor may utilize his own facilities or any commercial laboratory acceptable to the City of Fort Collins. The City reserves the right to perform or witness any of the inspections set forth in this Specification where such inspections are deemed necessary. 4.12 TEST REPORT The manufacturer shall furnish to the purchaser certified copies of the results of loss tests prior to payment. Copies shall be sent to the Design Section as well as with the invoice. Unsigned copies are not acceptable even if accompanied by a signed cover letter. The Quality Control Manager shall review and sign each test report. 4.2 TEST CONDITIONS Unless otherwise specified, testing required by Section 4.4 shall be conducted under the following conditions: 4.2.1 REFERENCE TEMPERATURE i The reference temperature to which losses, impedance, regulation, and efficiency are corrected shall be 85°C. 4.2.2 TOLERANCE ON IMPEDANCE VOLTAGE Impedance on completed units shall fall within the range specified herein. 4.2.3 TOLERANCE ON IMPEDANCE VOLTAGE ON A TAP The percent departure of tested impedance voltage on any tap from tested impedance voltage at rated voltage shall not be greater than the total tap voltage range expressed as a percentage of the rated voltage. 4.3 Not used. 4.4 TESTS The kinds of tests to be performed and the test procedures shall be as specified in ANSI C57.12.20, ANSI C57.12.00, and C57.12.90 except as specified herein. 4.4.1 DIELECTRIC TESTS No applied potential test shall be made. The induced -potential test shall be made by applying between the terminals of one winding a voltage which will develop from high -voltage line terminals to ground a voltage of 1000 volts plus 3.46 times the rated transformer winding voltage. 4.4.2 IMPEDANCE AND LOAD -LOSS TESTS Impedance and load -loss tests shall be made on each unit and may not be omitted even if a record of such tests made on a duplicate unit is available. 5 PREPARATION FOR DELIVERY Transformers shall be prefilled with the appropriate amount of transformer oil and shall be shipped by open -bed truck. Units shall be packaged in such a way as to provide for ease of handling and to protect units from shipping damage. 9 368-120 REV. SYM: FF Units shall be packaged on four-way universal pallets with 34 inches minimum opening and loaded on the truck for side removal. The Supplier shall give 24 hour notice prior to delivery for any shipments where an individual transformer weighs over 5,000 pounds. In addition to these requirements, the Supplier shall comply with any additional requirements or modifications shown on the purchase order and/or supplemental instructions. 6 DEFINITIONS AND ABBREVIATIONS Vendor or Supplier - The manufacturer and/or manufacturer's agent supplying or quoting on the specified article. Article, Unit, Assembly - All refer to the equipment defined by this Specification. • DC or d.c. - Direct Current. • AC or a.c. - Alternating Current. • •C - Degree Celsius (Centigrade) • °F - Degree Fahrenheit • kV - 1000 volts. • CPS or Hz - Cycles per second. • psig - Pounds per square inch gauge. • Vory- Volts. • KVA -1000 Volt-amperes. 10 368-120 REV. SYM: FF I APPENDIX A— Transformer Stock Number Coding Below are examples that demonstrate the coding method used by City of Fort Collins to establish transformer stock numbers. I. SINGLE PHASE Example #1 Transformer Single Phase 00 = 13.2Y/7620 & 7620/13.2Y x 2400/4160 outside pole 05 = 13.2Y7620 ESNA pole 20 = 13.2Y/7620 ESNA pad II. THREE PHASE Example #2 Transformer 3 Phase Pad 368 -1 006 = 75 015 = 150 030 = 300 050 = 500 Other KVA 0=5 5=50 1=10 6=75 2=15 7=100 3=25 8=167 4=37.5 9=250 1 = single voltage 2 = dual voltage 075 = 750 100 = 1000 150 = 1500 • All suffices indicate 208Y/120 sec. • For 480Y/277 sec., add 1 to XYZ lie. 007 would indicate a 75kVA with 480Y1277 sec.) 11 368-120 REV. SYM: FF APPENDIX B — DIMENSIONAL DRAWINGS 40" MAX 2B' MIN 4A' Sh' SV S t" 4t1I MIN MIN MIN I MIN MIN MIN MIN MIN 4lL) MIN i I H1A "HIB "X3 "X1 7'11' CABLE AMESSORY 32'mox x z PARKING STAND X2 CROUND PAD - 18'12" O� \O MAX. IM. KV A A 1N OUT RADIATORS N1TH RADIATORS 25 k 50-- 100 42' 167 250 • MINIMUM OPENING IN BOTTOM OF COMPARTMENT FOR CABLE ENTRANCE Figure 1 — Type 1 Transformer Dimensions and bushing Designations (not to scale) 12 368-120 20 Ea. TRANSFORMER, 100 kVA PAD -MOUNTED COMPARTMENTAL TYPE, SINGLE PHASE DISTRIBUTION WITH SEPARABLE�� �oU INSULATED LOAD BREAK HIGH VOLTAGE CONNECTORS. HIGH VOLTAGE RATING: 13200 GRDY/7620. LOW VOLTAGE RATING: 240/120. SERIAL NUMBER 170 TO BE IN ACCORDANCE WITH SPECIFICATION #368-120-170, REVISION FF PLEASE COMPLETE THE ATTACHED EXCEL SPREAD SHEET FOR BID SUBMITTAL. IF YOU ELECT TO PASSWORD PROTECT YOUR BID, PLEASE NOTE THAT PASSWORD BELOW. *Any surcharges or additional costs shall be noted & included in bid submittal. The transformers being bid meet or exceed the specifications. Yes No. If not, please list exceptions, (specifying paragraph reference number) on a separate sheet of paper and attach to your bid. Escalation is , is not applicable for the transformers bid. If escalation applies, the bidder shall indicate in his bid t t specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof. Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city. Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid. Delivery may be a consideration of bid award. For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid. The City of Fort Collins reserves the right to split the bid in whatever percentages are most advantageous to the City. Future orders of LP Transformers 25kVA & 100kVA, Padmounted, Single Phase may be authorized, at the option of the City, from this bid for a period of five years after date of award. Satisfactory pricing and delivery is required for future orders based on this bid. I INSIDE IZt°-2 TANK SURFACE DETAIL A CABLE ACCESSORY PARKING STAND I i BOTTOM FLANGE 4MIN 121 MAX HIGH -VOLTAGE CONNECTORS F CABLE ACCESSORY y REV. SYM: FF ONT 2.1 25� 2 2 MIN 3 2 MIN = x3G SEE CABLE ACCESSORY PARKING STAND E DETAIL A SEE DETAIL A 6 291/2 L 1 k 12 I° MIA 8 (NOTE 8) 26MIN 2 BSA LE GROUNDPAD 4I �I 8=1 BASE PLANE Z 4 Figure 2 — Type 2 Transformer Dimensions and bushing Designations (not to scale) 13 368-120 REV. SYM: FF Pad Dimensions This drawing is not intended to dictate requirements for items purchased under Specification 368-120 but is included as an aid to those users desiring a minimum of pad designs for the transformers covered by Specification 368-120. The dimensions in inches of Figure 3 will fit the minimum compartments on transformers covered by this Specification as well as the maximum transformer envelope. 48' None M POE MeleM! 1. Concrete.. Ine3,M pal mMarmn 2. MlWIYnI coarse agjle" eW l la NNb. Specs laqutiemenb W pad and primary switr mg calMettehi ga^^aM as 9'%12'. Faclons to Ea wngdsred N buthpMaPdNGude- t. AoRM1,111ty- The weasWmrr pad shai be toostaMaW lane Doom hl/da aqulpped for Me Installation and I al M Heavy atnshonrra. Such accessibility Mai not require Matti on adjacent popery. 2. paMnsy M Bananas. Was. Banana, 011WorC at;s - In aEdltldn W the tleaapaa requlad for Installation and amovY, Me mNrlum Waana M Qaed of tar Oenafomrr,d atoll M sight (8) lees and Me Mndreum Waance eom 0 timer sines a"i M too (2) het. II Me buiding Me an ovadang, Waance W Me edge of pro haasksn Rd Wg as meavuad IwKmab/ awn na wr/ edge M Me ova ,, Tlanskrmea Maugh 3Og WA may M Mideast under Me an a llo ng E Me v Ncal deaana bsMaen Me ped vW the overhang is at Most 25 Met and Me IDci Is accessible W Iles boom iNoea. ]. codes and 5landaNa - In addlam to Me Roves, Me Installation atoll coMolm to in. Natant ElscVlc Code and fedi state alto Oy cd]ne and Mandelda. Figure 3 — Pad Dimensions T3 a' I, UNG _1 _ TY a3 REBPR LENGTH ANO`M DTX 14 368-120 REV. SYM: FF I APPENDIX C — Approved Manufacturers Transformers purchased under this Specification shall be of the make shown below. Manufacturers not listed below may submit written proposals demonstrating compliance with these Specifications for consideration of addition to the accepted manufacturers list prior to the next request for bids. In addition to inclusion on the list below, manufacturer's equipment must also satisfy all requirements of this Specification to be acceptable. MANUFACTURER SERIAL NO. f�i All Cooper Power Systems All General Electric All Howard Industries All The manufacturers in the following list have been conditionally approved and may bid as an alternate. The definition and intent of "Conditional Approval' of a manufacturer is to allow the City to gain some experience with the manufacturer's product. Should a conditionally approved manufacturer be the evaluated low bidder, the City reserves the right to award all, part, or none of the order to them, dependant upon the current needs of the City for that item or items. 15 368-120 REV. SYM: FF TRANSFORMER LOSS EVALUATION - AVERAGE LOSSES City Order No. S/N Manufacturer Invoice No. KVA/UNt LINE DESCRIPTION AMOUNT (1) No. of units (2) Average core losses (3) Quoted core losses (4) Excess average core losses: line (2) less IIme (3) (5) Penal ttyy for excess average core losses: line (1) x line (4) x $ (6) Average copper losses (7) Quoted copper losses (8) Excess average coppper losses: line less line (�) (9) I(66) Pena fine 8j z average copper losses: (10) Penalty to be assessed manufacturer. line (5) plus line (9) but not less than zero Date Prepared By: Design Engineering NOTE: If any unit(s) exceeds the loss tolerances of ANSI C57.12.00, Light & Power will either reject it, include it on these averages, or calculate losses using the Individual Transformer Losses Evaluation Form, whichever is most favorable to Light and Power. 16 368-120 i INDIVIDUAL TRANSFORMER LOSS EVALUATION City Order No. S/N Manufacturer Invoice No. KVA/Unit LINE DESCRIPTION AMOUNT (1) Tested core losses (2) Quoted core losses (3) Excess core losses line (1) less line (2) but not less than zero (4) Percent difference % line (3) ❑ line (2) x 100 (5) Tested total losses (6) Quoted total losses (7) Excess total losses line (5) less line (6) but not less than zero (8) Percent difference j % line (7) D line (6)_x 100 I (9) Tested copper losses (10) Quoted copper losses It 1) Excess copper losses (12) line (9) less line (10) but not less than zero (12) Penalty for excess core losses line (3) x $ (13) Penalty for excess copper losses line (11) x $ (14) Penalty to be assessed manufacturer line (12) plus line It 3) Date Prepared By: Design Engineering REV. SYM: FF 17 368-120 Issued: 8/17/72 Revised: 1/21/94 Special Conditions and Supplemental Instructions to Bidders Applicable to Specification 368-120 A. Data to be Supplied with Bidder's Proposal The following data shall be supplied with the bidder's proposal in addition to that information required by the "Invitation to Bid" and the "Purchase Requisition". 1. A typical list of users of 1 phase padmounted distribution class transformers manufactured by the bidder during the past five years. 2. A typical drawing of the transformers showing that they will meet the critical dimensions required by the Specification. 3. Impedance volts in % at full load, high voltage to low voltage at 850C. 4. No load and total losses at 850C. 5. Delivery in weeks. 6. A statement indicating compliance with our Specification without exception or a detailed list of exceptions. 7. Escalation is _. is not _applicable for the transformers bid. If escalation applies, the Bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof. Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the City. Escalation occurring after acceptance, if Purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid. If the above information and compliance statement are not supplied, the proposal will not be evaluated. An alternate bid for the total order may be submitted in addition to the unit bids. B. Loss Evaluations Loss penalties and loss evaluations will be based on the following values: 1. No load or excitation losses at $3.90/watt. 1 2. Load losses at $1.50/watt. C. Shipping Terms Ship F.O.B. point of destination, freight prepaid. D. Terms of Payment If escalation applies, the City of Fort Collins shall not be billed for escalation occurring after the promised delivery date. 2. Test reports shall accompany the invoice. If test reports do not accompany the invoice, late payment penalty charges incurred due to delays in obtaining the test reports will not be paid. Certified copies of test reports shall be sent to the Design Section, Fort Collins Light and Power Utility. 3. Loss penalty credits and escalation charges shall be itemized on the invoice. SUPPLEMENTAL INSTRUCTIONS Prices quoted must remain firm for a 30 day period after the opening date. Freight terms: F.O.B. destination freight prepaid. All freight charges must be included in pricing submitted on proposal and not entered as separate pricing. Any discount allowed by Vendor for prompt payment, etc. must be reflected in quoted figure, and not entered as separate pricing. The City reserves the right to accept or reject any and all quotes. Bidder not responding to the services requested in this bid shall be removed from our automated listing for: Not Applicable Any questions or inquiries regarding this bid should be directed to: Opal F. Dick, CPPO, Senior Buyer (970) 221-6778 t s� Ate SIGNATURE AND TITLE: TYPED OR PRI —Di —�5w I EMAIL: NAME AND TITLE -?--7 r-x� AN ®D go P%®®®® Neg #: 11Q1369582 CITY OF FORT COLLINS -UTILITIES/ Wesco Distribution Inc / FTCollins7282 Item Alt Qty Description Price Each USD 10 30 25 KVA Liquid Filled Padmounted Transformer r/ DTR 2401, Jefferson City, USA (9AAE300179), PDC: 9AAC30400441, DTAN-L1S135 - /oC)(- 20 20 100 KVA Liquid Filled Padmounted Transformer � dr� 2 /a U� DTR 2401, Jefferson City, USA (9AAE300179), PDC: 9AAC30400441, DTAN-LlS135 V ABB Page 2 of 11 - 10/42011 NOTICE— 7hus document may contain confidential and privileged information for the sole use ofthe intended recipient. lfyou are not the inended recipient you mayner review, -copy -or distribute this message. Any review or distrih ition by others is strictly prohibited !f you are not the intended recipient. please contact the sender immediatelyand delete all copies. CITY OF FORT COLLINS - UTILITIES / Wesco Distribution Inc Neg #: 11 Q1 369582 / FTCollins7282 ITEM QTY kVA EACH (USD) NIL I LL TL %Z Shipment 10 30 25 59 @_85 1 234 @ 85 293 1.96 10-12 Weeks ITEM Customer Stock # 10 368-120-130 Quoted loss values are guaranteed average values. Description: Type Fluid Core Phase Frequency Average Winding Rise Ambient Temperature High Voltage High Voltage Taps High Voltage BIL Low Voltage Low Voltage BIL Feed Configuration Color Customer Specification Liquid -Filled MTR Maxi -Pak Padmounted Transformer Mineral Oil Grain Oriented Steel 1 Phase 60 Hz 65 °C 30 °C 13200GrdY/7620 +2 -2 2.5% 95kV BIL 240/120 30kV BIL Loop feed Green (Munsell 7GY 3.29/1.5) 368-120 Rev FF. 7/21/2004 Features (included in price); TANK & CABINET • 14" deep cabinet (13.25" deep sill) BUSHINGS • Bushing wells x 2 • Stud secondary x 3 FUSES • Partial range d fuse in series with bayonet MONITORING • Pressure relief valve OTHER • DOE Efficiency (2010) Scoop drip shield ABB Page 3 or I t 10/42011 NOTICE- Mis document may contain confidential and privileged information for the sale use ofihe intended recipient !flnu are not the inteadedrectpient you may not review, copy or distribute this message. Any renew or distribution by others is strictly prohibited. /fyou are not the intended recipient, please contact the sender immediately and delete all copies. CITY OF FORT COLLINS - UTILITIES / Wesco Distribution Inc Neg #: 11 Q 1369582 / FTCollins7282 20 1 20 1 100 ITEM Customer Stock # 20 368-120-170 Quoted loss values are guaranteed average values. Description: 1186@85I 689@85 875 2.15 I 10-12 Type Liquid -Filled MTR Maxi -Pak Padmounted Transformer Fluid . Mineral Oil Core . Grain Oriented Steel Phase 1 Phase Frequency . 60 Hz Average Winding Rise _ 65 °C Ambient Temperature . 30 °C High Voltage 13200GrdY/7620 High Voltage Taps : +2 -2 2.5% High Voltage BIL : 95kV BIL Low Voltage : 240/120 Low Voltage BIL : 30kV BIL' Feed Configuration . Loop feed Color : Green (Munsell 7GY 3.29/1.5) Customer Specification : 368-120 Rev FF, 7/21/2004 Features (included in price): TANK & CABINET • 14" deep cabinet (13.25" deep sill) BUSHINGS • Bushing wells x 2 • Stud secondary x 3 FUSES • Partial range G fuse in series with bayonet • Bayonet mounted expulsion fuse + isolation link MONITORING • Pressure relief valve OTHER • DOE Efficiency (2010) • Scoop drip shield Page 4 of I I 10/4/2011 NOTICE. -This document may contain corfdentialandprivilegedinformationfor the.sole use ofthe inleadedrecipient. /fyou are not the intendedrecipienlyou may not review,copy or distribute this message. Any review ordigribudon by others is strictly prahnined. Ifyvu are not the intended recipient, please contact The sender immediately and delete all copies. Ruchase CNdef Timm and Conditions 1, CONINEPtCMDETARS. Tax meaDma,.Bytnme MeC17 e[Fast Cohen i, eawp, ton,¢. aM kmlmm.Om Ens:pm N®mi, II.NON6'MT:R Ob04502. Fadm! Eulu Tn Eaemom Cmlkam a Reply N�517 n swooned MkM me Cab[n a Fe!lme Aides I9rtb,rt m iuiu gm =1 Dafmmame of b a:a, me [wdaom "At f ]seem dley. m Inval0.news, Dnnr, CelaNe RC Cek sU R«'sw Sax., 10]3, Cbapn 30-T0, lle (a). .aem,a mF,lFms m rem.dn Finatlae hae!a mq lose, lodes m pm➢ey sskfy Me S.R. As Miss-, et a 6 h. se a[[ey..d err Fa3'mos for Fouhh wAf epWeca! Mb let sbsN amnkeu Me SsW a OmGS Reiecral GOODS MTCTED na mkih:. As now¢ atM[Aw,. tib, aba,kppd m me m dKan of mot Me amana m abkmsom aftbs pmcbas.mdr mad stag Act be hsN a aaza of Any nPh at the daef. As ,...,.t. May, be need As Pan der snobs ,ad m am to b mbeN m,W amw MCA of wm:n PmcMva a uror gw,akt Pef[mvra[e hoa[m vyefnahnm caeca a m m' av3 Foods, rapuCm m—sMas mbCuye(Fm COCsss. ma]a elFyM rKm.dm acapmdasmm"IMAM m t¢eawa, dCamt bmnmde"am ebbs rnDVFMAd ¢L ae&I,,= ¢ raadtska of Ob Om'[tae miler by Me Pm[baa genera As e tram of ay of at tans In9a<nm GOODS Me gym be b CAP e[FmM Ce!!va vrp[ame m am, brtro[. Foal Aa,... Pec.pt of me merit -van, ..s m way ov As ras9aae to this wGa pv rash As 12. ASSIG !sMNiT OF A! : L'ST CLADS. scsh M pysimr w G Pm of b C, of Fan Codas. pmnx, A n m be aMaesoe Ca MAL S.N, m b Portia., ..yofe b, As aMol «omac p,._m, en:<mp, temlwF too M Mass ACCE➢TAVCE is dapneaa gm«¢ylaaw of MapptrebkrwnN to setl¢WMMaa. arohem m se fast basso by G Pr[baaa. Tberw a.' 55M Faadi. al ae[¢aamm fen aa®S MI, pm<bam ender. b SeIW haeq a AjAA m G P MIMMA m ad eH chat A my ma have m hvea Fra¢t Tees. Sblpmem sum be F.O E. CM of Fm Cods,, M Wood St. FN COL'c,, CO 105!!. ¢m As aW sea fedml m sate ausm, loses for nib m'mtapes rehwi As b Pads•'— FOMr m ursza aCemu apci abG+vea.upaaiaka h paver m pepaT teiim al OaFa apaaa7, me mival bight pmd As aymN by me pmcm,upenmm a Qu pnhm ender. n] mvacmpaT kvme.Admmml ciaM fmp[tW seiH err b. accaiam DFR NG£OF SfAtic i). PLPossam sboTvcd Pitsea pan arGCeemY,eymtm is ourmwyis.v chi MM'arATTOVS. VGpmL,sec,[mGSMrtm[mteaa¢<en`mcism, lavre WM,gaft. mNapeMapwgG Me Sea. .dismMm«sbm aaeaM 5ov b menu osatAnm poky m d¢mva of tam Alht ai0 b NdvnN Msm karma ohm i't, ➢mcbmr end G tarry Ms downs m mtr.^2)'m oxa5 c r sigma aaaaMe f:vn pram osmca. A A'A bend AA m A d .'Me shp Pay 4 mad Coe G cam m be pv'mcM q G sou mpdxi<m veers nvLbk m 6 cd be SMe,,bd py>7 no eaw[laed no w[b mml Plum. Seca ,bed Wmme At udm ask ram M mcnmy Ftmts, c.. ad Ikasis rwabN q .d spp aV kvx reitleoms, ere— n a! An of te sum, rare ' nssrm,F m im4mY �deamm mbn b mash k p,emmM m rwveG q vY myr daly rmaaxad phlk aOwL9 toy 3m,dumo am Qa kmt Mseedm. Sem fmtm,F.en m btl G C T o! Fm Cells IIadn, tom sea atmv M tabdny m bss ms.a q Gm q tow et a as.aN m nma'_... a:law err m eh k.s. nWkmm, md`�' a.e. w.s aengam'nrt. .ia`.s,rnma M pea m de cmnat ague Qn Ge uAe,maa[e, era. a dc; ben Cda � peaeaa GY vl =,A mmvy ahiesagepenef. LBHTTTON OF TERM& This w:[mt Qm .Rtsatly tiam a[gmce As b my err Caaohma emM mess'. (ad ere wy �t¢ay As m-.avl rm, m [cadent matl berm As ampmaad ham by name Any.ro ¢alme�8emm ma,nd[mmaem Wgmeequ^am dlKndm eras m.q NKtM DIFASE ADtRE pLRC9A51AG Af.EVi ®apmry m ya (®rc m,k[ [ ylaa [Lgmaa[ m u[tv ®Tim pmeeN 4tamy dv. a, vmei Ter[ k eft a,aa..OeyhutT cad pR®an mu b[ [!rind se@m G era tmM w G Iscbass ender m G dacwaau mcbM lam. Ne am of G Pccbso taarsmF aGbm F1m'_mt a[apaa[< ✓. iaCel can 4Y'nK a]N apnea n [ laver 0(b D(ORU[II lo G R'm of Cj d<hT. G P¢Cb,er,hM have, ca tlovaa m amrt kpl sib week ratdke. b gma Mp6ecaF my md.r.!arhne cad blmi G 5<Ctt bll. fen dawn. Hemam, b S.m stall err b aabk h Lxain n a r<M o(6loy+ r m[,m, m na,md7 ra.,«ark ahh a. b[F®d n rmmmh!. [eras me.rmmr n, fen tlmtnFm[., sub m of Cis andma�l mmhmy aadaflle. iataeCai p[a,des, bn, seh.e. Bead:.pfl¢ke. sum m en p[o[ 1[d Qn aen[< of G [minea, cave ,m] dfkT n Ln'n m Q< PxQ[aa.aba M+� l5) Hyi K Q< a[aba G SeBa fiv m<irMlmrkei[ mvn! h G <na R soy rah delay. Qe dam CNNvy sib! b m.aW h de perad e9ml m b of ¢many ben gnaw of b try. 3. R'ARAA!IFy'. Tb SMa ¢man der Mtosn, Aid. [mendge , Me rfl[tc[m rah qqL MAI d mCm, -sM sis ¢t : FM of, rdm la,mDOn, Matt nH b et W G DCDaen tmwdM m —L,, Ae W r]. hosier ape e[ Ald a [cam.mma o —Main a .m s, .a.md, !a[ .w e! e >Sb ame.:Te seen .pat m bdd b pm[ba« n elm hOm wF in,, daa[a m <apmn adcb G Pvehaur aa9 mtkr n mien w a<[® of b SM<n bn,[h et saatY. tM cart tbM mien, rryvr er rvke Lws nmma co m Gpx[bm, say dmcn w fmb and[ non cat (1)>m m m1Qca s¢h 1aaN perms M eeasnaybpavmNq lossmgbtense!eT7 eApfmabaanesy Proaid , bseder herGdte of a[ tfs [e!G pod, Mtxaltl mamar /a[[apm[. am m b ama,mm7 d•loyadt n,vmF tom tmFaka m e.r [.,a.an aaa m m,ta,w rmmbe q b s.ca. zagaa. m m. at poi, q' b vmm.a,beu seen 'a ofll[cam m0sfagmarry.Eaepaabtmhe Ratlsdmf Om[basum.badm tabevT bra®[a,bu mad m M aav[n Wem,uly ma,N by Me mssh etf my of G rm[m[ mmtmtw m Lvau«,, M mca bbitry k o not tittle loss atpata m Mne. ND D1ptlED R'ARRWTY ORS[EPSHAhTABHIR OR OF OF FRVESS FORD4'RDOSE SFUIL ADPLDLIt ,.CIGNGfS DF LEGAL iERNCS. Ibe Denham mymM<Cbxp, m lop! rm aymaa cha><. mdlr. 5. CFA:IGES w CON151ERCIAL TER]fs. The Pmsbm aril mde m [heap, As Qe tome. ads tam !.pit Mama. -ahtlhp admaom As m &Wang Mass Me Qmabn,.'MAU, eadrtM as the sPKr!a.wm As Ms. , by terbal m.... CbaP. sum. H m" inch cbaFt sbCn G sum® dd As G ®a efpmmaassommdn, m aembk aePvwtm sbM b mil. d. RTERN@murase—,mat:3. e Oa vy w by nova [bloc mess, nfmvm ash apeaam n m m As t0 pfnw, s so Pare Met AM dMet mgarner e0mnbhemas¢me bny Cea MeForms,amsnamrote. m Me Musk Ms. so pmmn ffbe der it pm[m,« ,bY oK M raise ten m clam, n' mothis. peen ee m. mcenak,M Pemw other Foesasscad. to MydsmvmCAM Me dens.,, msate ash tllmw.9ha mNaca fanssasSellalideespnanYFoe,ahbm Gsumssab'ibod t. Me tab kmI shM nam b Pocb,ambSafer of m'etbxetBlaom,amsoy Was, ds:aatl l<nmdc. ]. CIABIS FOR AD]LSI>IEI. Aay cbays for 4mwm .t be a,serad se.Qca di:1 (30) day, ten b don b flum of m aw is MAIAMA B. A Sea. iNCE1 Mat lose Ibf s.dK vane H m[ M Laad mA ! ii de ,M1 me. ben'Meds Me case , ssrwl a'W'!MN v ton <mapinan mxh M yDH[stle can m nFinatmm m setki G Mobs ere 1rO3Kt The term ebbs eza<aa sad eel. Ain avrybrcl—sm sbbKtewPoost"ham M hasfnntrlawtDiA sfdsub m[mpmud is old Ma Pu of dcs [amens as sang tvmpmatss Lorca by by Me Pull er sem epees e vd+c-h m1 batl G Palau, bola, Mee e! w, me emap..aE.rM q m. Pmn..a a.,.mH et mf Man fdmem[mpi' s,abym. 9. AssIGNSf£l.T. Ne,ho Imry [Y➢ ncW, awsm. m [mrey tC,mdr. «meY mask. am m m ba®a doe ]enmM nor® Ce parr anro cwsmt of CC ode perry. N. TITI£. The Sol a na dA cka eadamtmosadash m b Pm<bser h M w PAAMI memh:e, And. horded As vatmaaaa of ens tps Z Mn tAd my of M And 4 lie,. mass.. as...acw0' vnfm nc ..kacnnd[k Ada svt. The SeWr !lyre G Pmbart and es [acaamfe cf m ea Sm aD bob t, sad clams of eery mere fmh:vi tram bpn' <elsabaM. This Nem shaD apply.m At b nv a toul: of sohpae of G Fay stkased oaf shed Axed m the ft.. o6[m, and AMplAysiW fPl is Te hYeM1 t®[vY etlrpmm, mlmbt n:sy,,aa.l' err be de�N m le reffiM m crn. be<me m[bamk nPmmmM m <®ea sub put®ed q G Paimn. la PATENTS. 6Tm,mshs tom nf.0wtl ... sm d<mFn date, m:.ml m Wmns CmeMq leer, Pro, valmaQ m,g),tpm, ea SMe •a-n M¢v[y admit bmia„ ds Pmclao Sam m are aH [ha b dampmam by rtmaa offit As. At such pam<d dsv d<ava, enamel as pans ca cawna^a a G C Sam m .bM ne.:mry Q. Pmbnm v mF [me. e�.ae m emai. ¢tub v ley be ab!i;.e m pT q n„m erma M'vic�vamosdm&tl GFtns[mwmsfm G[m:loserMG Actsfsun At =d Moves cry padrtwfm G.mcp. ens aft FOA,k mcb and beL'mcemdee gate} taadGm. a[ utl oQimvm mpath eiTY—M GeSMa ,aM.auaxa ..maaepYa eE]a Gtmme fxG penhaur G r[y m [axle mcai »y wmpasa m Faq t4ca[e G sat nth mt,assBY egvl m ��eam, tmmaGS'v mvbaam«� T� is.MORET:CY. V b SaOa ,aa0 timer uW[m m bed make m aul¢sea br Ca bU Ot aadim. app�r rK<Fa a arena ten aJ pf Qa SMm Wopa:y m bvpe,4 t_" men maY !mdnd b! [>xe:tl q G D[mbam .dim aa.vry.. lbs. WS"ERVNGLA6. Tte n£xmm of terra madmb mmPmam of 8a e[raamm m dw,ytu cf It pen, teremdar stab cm.vmd In and Finamdgbhasalb SZK of Caimade, tSA. Tb AoUwosrizi AdGnaaL CwNaw, gply only As cast' aim G SeCr is e pw v taawda, mehdm G'.esofseC ft <..seOL w G Wfact' ofelm. 17. sEUtR] mwlvSI8mIT5'. n. S<Bn tba11 any, w eased wlk At Sedn]. suit wet ma sum, is ody<am;letol ad a<cynM are sbH ere N sa bite. M wM* . S ns v}ver m G seek vd'm vasofic b!an eM.r, ten! <amkwa ¢sibs anpma.,c¢yknbseen ¢MAMA, caseCorse matey Mee oa cfGsbc AAA— e:nala sm aasgmm m la . sh A lens h asm!aw m mcard q b SMm b SMrt eM ucan, mkM m«, ad ladle am, a aS an And bile tevpoitiN. Qamm„ mwFC mca muc«:, udm ,yaya'm m. b.hF Ma1dM by Ce Se W r ender Me o:M IF. NSLMW E. TW Sillier sleZ n hk ow Coeur, Wmils los essm—at of amkfn cvmaaavu hMni a[gmmrl Miss. bwda a m mplq'ma mptaya An m bs IMAM. seed the cart Cmmd by Cis pcdm coda. AAA to ba lFmdmv acconliAsicear]delaws a G[tae As a'S[h Me me@ is m b sum. The SMa shall rho tasoN Lsi 7. !atYVF. ben mot!Imue m. [ea_^a[ne! are ammohee pda[ 1b 7Ivmaa. rhb badCY calm) cad dead Imo of v ksm 5500,000 fen mF was Pow. {500,000 h m com actlat cad Wapny dama[. !St p: andw, of N00.000. ,Ter hY« shid a. ,cawes be cm¢a[mn. V m. m pmtN fen tab cwa.aama sod.vv:,se. B.ma aY of der S.m, err can cmnacmn mmygn,>DM do m cad nova Qf Wmkt' s[obn, m, sem+L:i fan:sh G Pmcbasaeti] d <.Ecm Gt mica [eapmasva and m�mmce Gs'e bees Wmidel. Sash [mvfxau, scar!! sp«sfy de eau vhev smE <wepfnuma era loam. me b.apm,adM soh m:aewte,,bad,p<iry b sun mbn mica <empmmdw and papnea Thf Sa51a [mess mas,ma [wyfmow sib nmavice [bed baaaaN ¢vl afm m. mtn Arseaft n mt ncemkMmd vrepM 19. PROTECTION AGADtST ACC=TS AND DANLiGES. Inc b.!!a brtq Harrah odempwm3Ep'mtabiWy [sumevd MdmaW, lens mri ]'a[ary lssi •aLtwna mptue[m9 Tatt)'<msNbYmr«WnaiM®d[anmaoa afeevod ¢o[N[G Ert¢ tG pxcbu md[r m a [waaow meals Ib SemnC k�tmgR' eras hotl bwka, de DIS<Leirt ad m m a:l of G Pvcmm aBco, s[wn m myby.ss Men m aFacs[ m sae M C^ hung dwpt cops mlapta.ee. amen dgm m tvdinct sad mbeb: m pasws m ProPefi, m ab:d b Pvrheur nap b Ddmmtjfctyrtam ofsay sic,[we.sfl ®hikers MricimbpIs a!G S Amold, Cwvxan, m m of Me SMm m [omatms oMco. a. -sun or eas»'en. d mu m sent m odor WmsaeQFs still b mash[ epos[ der Pmcbsu. m sh vftco. aFaan m awkYns tt mT me w acvaa m q [sum M sup at ram. mpKt avi[wv m ndv:t set b h[« tl m v[ k, [ma,mm, m m tl m m bk ofHcm. ., i m <mlgefs as .. As a Sem a sosis.peesestMul harwf and m MCkvd b sm,t G Met SAIas era tapfm, m py sup e 1 M [nq [bases, s. err A, fen ttl s Ma s of fto . .q and all pdiwID urb A s caNgmaba�aeeaFakatb PMeAs maser a[iamd[k ells. spans PMsAt , [mn.vnma]c Frm.[m F4ad n mu.Msuha[mmho Ln be *NM eywm obmmN eWaat Cs irmfnY o(Q<Padasrt, m.aA pvrcn is m as a rn h of tan svn m ads p:oceNmFe. ens SemaL n ens emu b eam a be dsmkN and ounai<eq Ficcaibwdmeeemiu. Tb semmd sc co®a[sm .had eke all mr4 WK,W . !Ant r' memo safe, Wed bus: Fm de prnmaw of addan. cam1Y ne Hs Im cad 1970 AM , nobs rtnad m .scan m<GsR asi nd[m tiafama b or[wanosa hfery, W Hee:e M of 19]0 vb all,skAnd nFnlstays y,md pmavt don THE CITY OF FORT COLLINS I Light and Power Department P.O. Box 580 Fort Collins, CO 80522 SPECIFICATION NO: 368-120 TITLE: PAD -MOUNTED COMPARTMENTAL -TYPE, SINGLE-PHASE DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED LOAD BREAK HIGH -VOLTAGE CONNECTORS APPROVED BY: 'A /� Kraig E. ad Standards Engineering Manager ORIGINATED: 09/14/72 LAST REVISED: 7/21/2004 ITEMS COVERED BY THIS SPECIFICATION DESCRIPTION STOCK NO. SPECIFICATION NO. SERIAL 25 KVA, 120240 ANSI Type 1 Transformer. 1 368-120 -130 50 KVA, 120240 ANSI Type 1 Transformer. 368-120 -150 50 KVA, 120/240 ANSI Type 2 Transformer. 368-120 - 155 100 KVA, 120/240 ANSI Type 1 Transformer. 368-120 -170 167 KVA, 120240 ANSI Type 1 Transformer. 368-120 -180 250 KVA, 120/240 ANSI Type 1 Transformer.' 368-120 -190 REV. SYM: FF PREVIOUS REVISION DESCRIPTIONS ON FILE REVISION DESCRIPTION APPROVED REVISION DD: Sagan • Paragraph 3.2.2.7.5: Editorial 10/21/94 • Add paragraph 3.2.2.9.4 requiring pentahead locking bolts • Paragraph 3.2.2.13 add glossy to paint requirement • Paragraph 4.2.2: Clarify impedance requirement REVISION EE: Sagan • Paragraph 5.0: revised pallet size from 28 to 34 inches 2/25/98 REVISION FF Kraig Bader • Added 50kVA ANSI Type 2 Transformer (368-120-155) to Specification 7/212004 • Changed paint color to standard Munsell Green • Reorganized to consolidate impedance and fusing requirements into one table. • Consolidated secondary terminal requirements into one table. • Added maximum impedance requirement for 250kVA transformer (+/-7.5% from nominal for transformers with impedance greater than 2.5%) per ANSI/IEEE C57.12.00-2000. • Re-evaluated fusing requirements of all transformers in this specification. Went from dual sensing bay-o-net (expulsion) fuses to curent sensing bayonet (expulsion) fuses. Fuse sizing was changed as follows: • Changed 25 kVA from 8A expulsion / 40 amp CL to 10A expulsion / 30A CL • Changed 50 kVA from 15A expulsion / 80 amp CL to 15A expulsion / 40A CL • Changed 100 kVA from 25A expulsion / 175 amp CL to 25A expulsion / BOA CL • Changed 167 kVA from 40A expulsion / 200amp CL to 40A expulsion / 125A CL • Changed 250 kVA from 65A expulsion / 350amp CL to 65A expulsion / 125A CL 2 368-120