Loading...
HomeMy WebLinkAboutRESPONSE - BID - 7232 CITY PARK MINI SHELTERSCity of Financial Services III Purchasing Division 215 N. Mason St 2n° Floor ®rt Colli n s PO Box 580 Fort Collins. 80522 970.221.6775 Purchasing 970.221.6707 fcgov.com/Purchasing INVITATION TO BID 7232 CITY PARK MINI SHELTERS BID OPENING: 3:00 P.M. (our clock), May 10, 2011 Sealed bids will be received and publicly opened at the office of the Director of Purchasing and Risk Management, PO Box 580, 215 North Mason St., 2nd floor, Fort Collins, Colorado 80522, at the time and date noted on the bid pro�osal and/or contract documents. If delivered, they are to be sent to 215 North Mason Street, 2" Floor, Fort Collins, Colorado 80524. If mailed, the address is P.O. Box 580, Fort Collins, 80522-0580. Bids must be received at the Purchasing Office prior to 3:00 p.m. (our clock), May 10, 2011. Technical questions should be referred to Eileen Scholl, Project Manager at (970) 416-2062 or e-mail at escholl(cDfcgov.com. Questions regarding bid submittal or process should be directed to John D.Stephen, CPPO, LEED AP, Senior Buyer at (970)221-6777 or email at istephenC@fcgov.com. A copy of the Bid may be obtained as follows: Download the Bid from the Purchasing Webpage, Current Bids page, at: http://fcgov.com/eprocurement 2. Come by Purchasing at 215 North Mason St., 2nd floor, Fort Collins, and request a copy of the Bid. Special Instructions All bids must be properly signed by an authorized representative of the company with the legal capacity to bind the company to the agreement. Bids may be withdrawn up to the date and hour set for closing. Once bids have been accepted by the City and closing has occurred, failure to enter into contract or honor the purchase order will be cause for removal of supplier's name from the City of Fort Collins' bidders list for a period of twelve months from the date of the opening. The City may also pursue any remedies available at law or in equity. Bid prices must be held firm for a period of forty-five (45) days after bid openings. Submission of a bid is deemed as acceptance of all terms, conditions and specifications contained in the City's specifications initially provided to the bidder. Any proposed modification must be accepted in writing by the City prior to award of the bid. Only bids properly received by the Purchasing Office will be accepted. All bids should be clearly identified by the bid number and bid name contained in the bid proposal. No proposal will be accepted from, or any purchase order awarded, to any person, firm or corporation in default on any obligation to the City. Bid 7232 City Park Mini Shelters Page 1 of 13 SQR10-MR CITY PARK MINI SHELTER FORT COLLINS, CO Revision: 5/6/2011 Supply manufacturer's standard 10-year limited warranty on frame and 10-year limited warranty on paint system as specified. PART2 - PRODUCTS 2.1 DESCRIPTION OF PRODUCT MODEL NUMBER AND SIZE: SQR10-MR 10' SQUARE 4 COLUMN STYLE SHELTER 2.2 ACCEPTABLE MANUFACTURER A. Poligon, a Product of PorterCorp, 4240 N 136th Ave., Holland, MI, 616.399.1963; E-mail: info@poligon.com; www.poligon.com. B. Substitutions must be approved a minimum often (10) days before bid. All approved manufacturers shall be notified in writing before the bid date and shall not be allowed to bid without written notification. C. Alternate suppliers must meet the qualifications and provide proof of certifications listed under section 1.7 QUALITY ASSURANCE. D. Alternate suppliers must provide equivalency to the specified paint system. E. Alternate suppliers must provide proof that their designs do not infringe on patents or copyrights. 2.3 MATERIALS A. STRUCTURAL FRAMING: Structural steel tube minimum ASTM A500 grade B, "I" beams, tapered columns, open channels, or wood products shall not be accepted for primary beams. Frame will have a STANDARD POLI-5000 Color chosen from manufacturer's standard color chart: B. COMPRESSION MEMBERS: Compression Ring: Structural channel or welded plate minimum ASTM A36 or Compression Tube: Structural steel tube minimum ASTM A500 grade B. C. STRUCTURAL FASTENERS: ASTM A325 high strength bolts and A563 high strength nuts, ASTM A307 anchor bolts. E. PRIMARY ROOF SYSTEM OF "R" PANEL/MULTI-RIB METAL ROOFING: Multi -rib roofing shall be 24 gauge ribbed galvalume steel sheets with ribs 1 3/16" high and 12" on center. Roof surface shall be painted with Kynar 500 to the manufacturer's standard color TBD. Ceiling surface shall be white. Roof panels shall be factory precut to size and angled to provide one-step installation. 1. Metal roofing trim shall match the color of the roof and shall be factory made of 26 gauge Kynar 500 painted steel. Trim shall include panel ridge caps, eave trim, splice channels, lrg®n" STEEL SHELTERS by PorterCorp * Holland, MI * 49424 CSI Section 10 73 00 www.poligon.com * 800-354-7721 * fax 616-399-9123 Page 5 of 6 SQR10-MR FORT COLLINS, CO CITY PARK MINI SHELTER Revision: 5/6/2011 roof peak cap, and corner trim as applicable for model selected, reference drawings for additional information. Painted screws and butyl tape are included. 2. Ridge Caps shall be preformed with a single central bend to match the roof pitch and shall be hemmed on the sides. 3. Roof peak cap shall be supplied on all buildings (that do not include a cupola). 4. Thirty pound felt and nails shall be provided when T&G roof deck or SIP roof deck is ordered along with metal roofing. 2.4 ACCESSORIES/OPTIONAL 2.5 FABRICATION A. All steel fabrication of tubes and plates shall be factory controlled under a documented Quality Management System. All parts shall be permanently etched with identification numbers. Fabrication facility will be experienced for a minimum of ten years in precision tube and plate fabrication. Cumulative experience in fabrication will not be an acceptable alternative. B. Certified AWS welders shall make all welded connections in accordance with AWS Specifications and trained by an on -staff AWS Certified Welding Inspector. PART 3 - ERECTION A. FOOTINGS: The shelter shall be set on prepared footings designed by Poligon, anchor bolts to be provided, and concrete slab (if required) provided by others. The design engineer shall be presented with complete information about the site including soil bearing and lateral load capacity. If soil data is not provided, the design engineer will design footings to the minimum values identified in IBC Table 1804.2 Allowable Foundation and Lateral Pressure. The contractor must use appropriate construction practices for the specific site conditions. B. Install all components according to manufacturer's installation instructions and these specifications. END OF SECTION lklon" STEELsHELTERs by PorterCorp * Holland, MI * 49424 www.poligon.com * 800-354-7721 * fax 616-399-9123 CSI Section 10 73 00 Page 6 of 6 Poligon Product Specification Form PROJECT PROJECT LOC CUSTOMER ADDRESS WIND LOAD: SNOW SEISMIC DESIGN: BLDG Le- 0-4- i U; '• PORTERcoae^� t !� ro.nxoar. as N.ixm.Nl yow.No.w .v.z. Pke-TLA-4a- (JbtlA.Q l'Pi� �Pj� w��` �1G.vt. to' ..pollgon.com BM354-]]21 It IF 2 of �E gx�s TOIC Y x % % X % % Y Y X % % % % Y Y I % % % % % Z % % x % % fryn•. MIt1Al! % Z x% Lx1i1xix Y x X%% Y x RMI xt. w x x x x x x x x x x x x x x Y..m IT ReeR LEGEND: X STANDARDCOLOR + SIGNIFICANT UPCHARGE FOR THESE COLORS SELECT ANCHOR SYSTEM: ❑ EXPOSED RECESSED ❑ EXPOSED / FLUSH ❑ CONCEALED ❑ BURIED COLUMN SELECT MODIFICATIONS TO A STANDARD: INCREASE UTM, HEIGHT: ADD ELECTRICAL CUTOUTS: ADDCUPOLA:_ ADD ORNAMENTAPON:_ ADD BENCHES: ADD HANDRAILS: SELECT APPLICABLE ROOF TYPE: ❑ MR (Metal Roof) ❑ SPMR (Structural Panel or ❑ TGMR (Tongue &Groove ❑ SS (Standing Seam Roof) ❑ SPSS (Structural Panel un ❑ TGSS (Tongue & Groove ❑ SPAS Structural Panel ur ❑ SPCS IStructural Panel ur ❑ SPCHStructural Panel ul ❑ TGAS longue & Groove ❑ TGCS Tongue S. Groove ❑ TGCH (Tongue S. Groove ❑ LATIA (Santa Fe metal stir ❑ TRELLIS SELECT CUSTOMIZATION: INCREASE UTM MORE THAN 2: CUSTOM COLUMNS:_ CUSTOM PITCH:_ ADD E-COATING FRAME:_ ADD GALVANIZING FRAME:_ aal%aoq REFER TO WWW.POLIGON.COM Metal Roof) DOWNLOAUATEA-FO (dingg Seam) FOOTING AND ANCHOR tan ling Seam) INFORMATION halt Shin lesI COLUMN STYLE OPTIONS dar Shingles) CUPOLA OPTIONS ed Cedar Shin lost ORNAMENTATION STYLE OPTIONS kspholt Shinglest _edor Shingles) INTEGRATED BENCH OPTIONS Milled Cedar Shinglest ' MISCELLANEOUS OPTIONS PORTERCORP MANUFACTURES AND DELIVERS PRODUCT IN STRICT COMPLIANCE TO GOVERNING BUILDING CODES. SHEET INDEX C6VER SHEET / ORDER FORM • ELEVATION VIEWS • STRUCTURAL FRAME • ANCHOR LAYOUT SQUARE 12 SQR-12 . M M PAKHI�CM Desgrc aM cok�bibns of Pofgon do 11 or. palecledu r,, c.yngM11 and Ro 1. fenn and may rrol W.S in IMeMnrvcfron or desgn ofo t NR I., a—tsweFed M Pdipon. °1' PORTERco" W¢RCCOw, 42tl N. .Ig1w .'I'l. Snrn w .pongon.com 800-354-7721 COVER SHEET /O f 3B'-Fir4' SQUARE NOTE: THIS IS A PLANNING LEVEL DRAWING. THE STRUCTURE SHOWN IS SUBJECT TO ^" ^"IGN REVIEW AND T SOME CHANGES ES AND GENERAL NLY USE DRAWINGS ENGINEERED R CONSTRUCTION. AL MEMBEF FRAME AND ORNAMENTATION FINISH: MEMBERS SHOT BLASTED TO NEAR WHITE CONDITION CSOATED WITH SUPER DUR BLEWASHED ANDALED TGIC POLYESTER POWDERAY AND OVEN CURED, SEE COLOR MATRIX FOR AVAILABLE COLORS. OPTIONAL UNDERCOAT: EPDXY E-COAT SYSTEM, USING FULL IMMERSION ELECTRO-DEPOSITION PROCESS. NOTE: THIS IS A PLANNING LEVEL DRAWING THE STRUCTURE SHOWN IS SUBJECT TO ON -GOING DESIGN REVIEW AND UPDATE. EXPECT SOME CHANGES TO MATERIAL SIZES AND GENERAL DIMENSIONS, ONLY USE DRAWINGS PROVIDED WITH ENGINEERED STRUCTURES FOR CONSTRUCTION. paligonf pards®I' Potigon, Parasol, and Pinnaele POftefSips Limited Warranty and Limitations gp E PorterCorp warrants the building structure for 10 years from shipping date with the FRAME$- following limitations. (Paint System Warranty 7.2fm24 is a separate document.) PorterCorp limits its warranty to the supply of materials that will fit, be structurally sound, and can be assembled with normal expertise and with tools required and found pinnae e in the construction trades. It is expressly understood that PorierCorp's Liability be limited to repair or replacement of nonconforming material at time of delivery. 4240 No. 136th Ave. Holland, MI 49424 80 0.3 54.7 721 Ph: 616.399,1963 Fx: 616.399.9123 www.portercorp.com PorterCorp does not warrant product for defects caused by erection, harsh site conditions, lack of maintenance, and/or other conditions beyond PorterCorp's control. PorterCorp shall not be held liable for field alterations. PorterCorp shall not be held liable for meeting unspecified building codes or for updating designs or specifications to meet new building codes or insurance standards either existing or updated. PorterCorp shall not be responsible for delays due to missing and/or nonconforming parts. Parts short -shipped and non -conforming parts will be replaced or reworked by PorterCorp as a top priority. Any rework of non -conforming parts by the contractor must be authorized by PorterCorp prior to rework. PorterCorp shall not be liable for any act of God, fire, vandalism, settlement, incidental or consequential damages, erosion of foundation, or extreme site conditions. This Limited Warranty supersedes all other warranties expressed or implied. The warranty on metal roofing, fabric, and shingles will be as passed through PorterCorp's Supplier as per their warranty, contact Customer Service for Supplier Warranty. This Limited Warranty is conditional upon payment in full to PorterCorp within terns. PorterCorp will not be held responsible for any materials that were not properly stored prior to installation. Liability under this Warranty is limited in that it shall not exceed the original sales price of the components as supplied by PorterCorp. 7.2I'm 1901/11/08 REFERENCES Poligon Park Shelters - Colorado DOUGLAS COUNTY PARKS & TRAILS Contact: Curt Sloan 303-470-0140 Email: csloan@dogulas.co.us TOWN OF WINDSOR Contact: Wade Willis 970-674-2434 Email: wwillis@windsorgov.com TOWN OF JOHNSTOWN Contact: Don Gardner 970-587-4664 Email: dgardner@townofjohnstown.com CITY OF COLORADO SPRINGS PARKS & RECREATION Contact: TIM PLUEMER 719-385-6524 Email: tpluemer@springsgov.com CITY OF LONGMONT Contact: James Curts 303-651-8447 Email: james.curts@ci.longmont.co.us J ,, PARK ARCHITECTURE all all 1*1 OII Hill •••_ ., •arc crra nII man■IN 1, IIa Yf III8 ■ifi t[■ 1[[ ■Z6 ■[[ IU ■16 [OI 01 a...rr....F...r«-�- 1909 1991LI 0 � _ pwr —Z-. 0 9 f 190 Q- 2001 Elm 2903 The Evolution of Tubular Steel Shelters VO /M1Le IJOJI SJ0.«la . h. (303) 5a0.fl23fl . Tdl frN (900)12C.)5]9 p6ligon® PARK ARCMs CNR A d rds�1. pinnacGGlc- P «�os« a d a rt Mportersips- A EIMKEL 6UUDIM08 structural insulatetl panels PORTERCORPTM Innovattn4 bulldina system5 since 1964 PORTERCORP 4240 N. 136th M. - Holland, MI 4 4 vn<w Iigon.com-B003 .Ml- CopogM 0200E L934 Bids must be furnished exclusive of any federal excise tax, wherever applicable. Bidders must be properly licensed and secure necessary permits wherever applicable Bidders not responding to this bid will be removed from our automated vendor listing for the subject commodities. The City may elect where applicable, to award bids on an individual item/group basis or on a total bid basis, whichever is most beneficial to the City. The City reserves the right to accept or reject any and all bids, and to waive any irregularities or informalities. Sales prohibited/conflict of interest: no officer, employee, or member of City Council, shall have a financial interest in the sale to the City of any real or personal property, equipment, material, supplies or services where such officer or employee exercises directly or indirectly any decision - making authority concerning such sale or any supervisory authority over the services to be rendered. This rule also applies to subcontracts with the City. Soliciting or accepting any gift, gratuity, favor, entertainment, kickback or any items of monetary value from any person who has or is seeking to do business with the City of Fort Collins is prohibited. Freight terms: unless otherwise noted, all freight is F.O.B. Destination, Freight Prepaid. All freight charges must be included in prices submitted on proposal. Discounts: any discounts allowed for prompt payment, etc., must be reflected in bid figures and not entered as separate pricing on the proposal form. Purchasing restrictions: your authorized signature of this bid assures your firm's compliance with the City's purchasing restrictions. A copy of the resolutions is available for review in the Purchasing Office or the City Clerk's Office. Request Resolution 91-121 for cement restrictions. Collusive or sham bids: any bid deemed to be collusive or a sham bid will be rejected and reported to authorities as such. Your authorized signature of this bid assures that such bid is genuine and is not a collusive or sham bid. Bid results: for information regarding results for individual bids send a self-addressed, self -stamped envelope and a bid tally will be mailed to you. Bid results will be posted in our office 7 days after the bid opening. James B. O'Neill II, CPPO, FNIGP Director of Purchasing and Risk Management Bid 7232 City Park Mini Shelters Page 2 of 13 CITY OF FORT COLLINS BID PROPOSAL 7232 City Park Mini Shelters BID OPENING: 3:00 P.M. (our clock), May 10, 2011 WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR City Park Mini Shelters PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS: The City of Fort Collins Parks and Recreation Department is requesting bids for providing and delivering three (3) 10' X 10' shelters to job site, unloading of shelters and installing shelters for a complete product. Awarded contractor must enter into the attached service agreement (for your review) and provide the required insurance (Exhibit B). Bidder Qualifications A. At least (3) three years consistent, hands on experience in commercial construction and awarded contractor must be able to demonstrate this through references. B. Please provide list of at least (5) five jobs completed with contact information including current name and phone number. BID SCHEDULE Service Provider to provide, deliver, unload and install shelters for complete product. $ /D, D/S. ov per shelter X 3 = Base Bid $ 30, OqS. 400 In Words FIRM NAME Are you a Corporation, Partnership, DBA, LLC, or PC SIGNATURE ADDRESS ,AO K�auoT �d �OS�iF� PHONE/FAX # 303 • s30 • Ally' / 303 53o - 9L3� E-MAIL ADDRESS G4ra e chtcrt hteAjdee r-e L+L} M.ne+- Bid 7232 City Park Mini Shelters Page 3 of 13 SCOPE OF WORK Responsible for providing and delivering three (3) 10' X 10' shelters to job site, unloading of shelters and installing shelters for a complete product. There will be no electrical to shelters and no concrete pad. Contractor will be responsible for fine grade work after installation. Contractor will be responsible for obtaining any necessary permits, the city will pay permit fees. Picnic shelter specs: 10' X 10' steel square hip shelter, 24 gauge precut multi rib metal roof panels, powder coated frame, anchor bolts, 6" square buried columns with footings, freight and engineered stamped drawings. Color to be specified by owner. Bid 7232 City Park Mini Shelters Page 4 of 13 City of ®rt Collins Uchas• i ADDENDUM No. 1 SPECIFICATIONS AND CONTRACT DOCUMENTS Description of BID: 7232 CITY PARK MINI SHELTERS OPENING DATE: 3:00 P.M. (OUR CLOCK), MAY 10, 2011 Financial Services Purchasing Division 215 N. Mason St. 2ntl Floor PO Box 580 Fort Collins, CO 80522 970.221.6775 970.221.6707 fcgov. com/purchasing To all prospective bidders under the specifications and contract documents described above, the following clarification is hereby made: Each mini shelter must have 4 columns Please contact John D.Stephen, CPPO, LEED AP, Senior Buyer at (970)221-6777 orjstephen@fcgov.com with any questions regarding this addendum. RECEIPT OF THIS ADDENDUM MUST BE ACKNOWLEDGED BY A WRITTEN STATEMENT ENCLOSED WITH THE BID/QUOTE STATING THAT THIS ADDENDUM HAS BEEN RECEIVED. Addendum 1 7232 City Park Mini Shelters Page 1 of 1 SQR10-MR CITY PARK MINI SHELTER FORT COLLINS, CO Revision: 5/6/2011 Poligon Steel by PorterCorp 4240 136`" Ave., Holland, MI 49424 Product Guide Specification DIVISION 107300 SPECIALTIES MANUFACTURERS OF PROTECTIVE COVERS PART1 - GENERAL 1.1 SECTION INCLUDES Prefabricated metal shelter/gazebo/pavilion. 1.2 RELATED SECTIONS Cast -In -Place Concrete, Section 03 30 00. 1.3 REFERENCES A. American Institute of Steel Construction (AISC). B. American Iron and Steel Institute (AISI) Specifications for Cold Formed Members. C. American Society of Testing of Materials (ASTM). D. Steel Finishing. 1. STANDARD POLI-5000 FINISH: a. For quality control purposes, steel shall be cleaned, pretreated and finished at a facility owned and directly supervised by the manufacturer. Steel shall be shot blasted to SSPC-SP10 near -white blast cleaning. SSPC-SP2 hand tool cleaning will not be an acceptable alternative. Parts shall be pretreated in a 3 stage iron phosphate or equal washer. Epoxy primer powder coat to be applied to parts for superior corrosion protection with a top coat of Super Durable TGIC Powder Coat. For environmental purposes, finish shall allow no VOC emissions. b. For quality control purposes the supplier applying the powder coat shall be PCI 4000 S Certified which covers meeting the requirements in: pretreatment, ovens and curing, control, application area, quality control, training, maintenance, customer satisfaction, safety, process incoming quality control, and loading, unloading, and packaging. For additional information go to www.00wdercoating.org. c. All visible areas of exposed nuts, bolts, and washers for frame and ornamentation connection shall be powder coated to match the frame to minimize installer's time in touching them up. The threads shall be protected for ease of installation (nuts, bolts, and washers). n poligo® STEEL SHELTERS by PorterCorp * Holland, MI * 49424 CSI Section 10 73 00 www.poligon.com * 800-354-7721 * fax 616-399-9123 Page 1 of 6 SOR10-MR CITY PARK MINI SHELTER FORT COLLINS, CO Revision: 5/6/2011 d. If there is a functional cupola, all exposed structural bolts shall be painted to minimize installer's time in touching them up. e. All heads of fasteners for purlin and u-clip connections shall be painted to minimize installer's time in touching them up. f. Sample production parts shall have been tested and meet the following criteria: 1) Salt spray resistance per ASTM B 117/ ASTM D 1654 to 5000 hours with no creep from scribe line and rating of 10. 2) Humidity resistance per ASTM D2247-02 to 3000 hours with no loss of adhesion or blistering. 3) Color/UV resistance per ASTM G154-04 to 2000 hours exposure, alternate cycles with results of a) no chalking b) 75% color retention c) Color variation maximum 3.0 E variation CIE formula (before and after 2000 hours exposure). E. American Society for Quality (ASQ). F. American Welding Society (AWS). G. International Building Code (IBC). H. Leadership in Energy and Environmental Design (LEED). Lightning Protection Institute (LPI). J. National Fire Protection Association (NFPA). K. National Recreation and Park Association (NRPA). L. NTA Inc. (Third Party Auditor). M. OSHA Steel Erection Standard 29 CFR 1926 Subpart R-Steel Erection. N. Powder Coating Institute (PCI). O. PCI 4000 S Certification. P. Steel Structures Painting Council (SSPC) SSPC-SP10 Near White Blast Cleaning. 1.4 CONTRIBUTION TOWARDS LEED CREDITS A. LEED SS Credit 7.1: Sustainable Sites, Heat Island Effect/Non-Roof. B. LEED SS Credit 7.2: Sustainable Sites, Heat Island Effect/Roof. C. LEED MR Credit 4.0: Material and Resources, Recycled Content. D. LEED MR Credit 5.0: Material and Resources, Regional Material. IOND hGon� STEEL SHELTERs by PorterCorp * Holland, MI * 49424 CSI Section 10 73 00 www.poligon.com * 800-354-7721 * fax 616-399-9123 Page 2 of 6 SQR10-MR FORT COLLINS. CO 1.5 SYSTEM DESCRIPTION CITY PARK MINI SHELTER Revision: 5/6/2011 A. PRODUCT DESIGN LOADS: IBC (2009 edition) 36, pounds per square foot ground snow Ioad,110 mile per hour basic wind speed, site specific seismic zone requirements. B. DESIGN METHOD: As a minimum the engineering calculations submitted shall include the following: 1. Building Codes and design manuals used for calculations. 2. Formulas used for determining loads specific to project location. 3. Three dimensional modeling input, model geometry, and analysis results. 4. Member design results and controlling load cases. 5. Connection design for bolts, welds, and plate thicknesses. 6. Foundation design including vertical and lateral load effects. Foundation designs must include the worst case effects due to wind or seismic loads. C. The pre-engineered package shall be a pre-cut and pre -fabricated package that shall include powder coated structural frame members, roof material, fasteners, and trim as well as the installation instructions. The structure shall be shipped knocked down for minimum shipping charges. Field labor will be kept to a minimum by pre -manufactured parts. No onsite welding will be permitted. Connection bolts shall be concealed within the tubing where possible. D. Where possible, tube column to concrete base will be surface mounted with all anchor bolts hidden within the column. Each column will have a minimum of four anchor bolts to meet OSHA safety requirements. E. Where possible, the structure will have a moment connection at the top of the column and a pinned connection at the base of the column to ensure a clean connection at the base, reduce the size of the concrete foundation, and provide for one-step concrete installation process. 1.6 SUBMITTALS A. GENERAL SUBMITTAL: Submit 4 sets of signed and sealed submittal drawings by a Professional Engineer licensed in the State of Colorado and 2 sets of calc books. B. Structural calculations shall be in conformance to item 1.5 B under System Description. 1.7 QUALITY ASSURANCE Provide evidence of commitment to quality craftsmanship as demonstrated by the following: A. SUPPLIER QUALIFICATIONS: 1. The product shall be designed, produced, and finished at a facility owned and directly supervised by the supplier who has at a minimum of ten years under same ownership o19190"' STEEL SHELTERS by PorterCorp * Holland, MI * 49424 CSI Section 10 73 00 www.poligon.com * 800-354-7721 * fax 616-399-9123 Page 3 of 6 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. SQR10-MR CITY PARK MINI SHELTER FORT COLLINS, CO Revision: 5/6/2011 making steel frame pre -manufactured shelters. Staff members' cumulative experience in fabrication will not be an acceptable alternative. 2. The product shall be shipped from a single source. 3. Annual audit of the Powder Coat Finishing System (Shot Blast, Powder Coat) by Third Party Agency (PCI). Annual audit of Quality System by Third Party Agency (NTA Inc.). Membership in American Institute of Steel Construction. Membership in American Society for Quality. Corporate Member of American Welding Society. Membership in Chemical Coaters Association International. Membership in Construction Specifications Institute. Membership in National Recreation and Park Association. Corporate Member of Powder Coating Institute. Full time on -staff Licensed Engineer. Full time on -staff Quality Assurance Manager. Published Quality Management System. Full time on -staff AWS Certified Welding Inspector. Continued certification by an independent inspection agency. Control of finishing quality by in-house shot blast, pretreatment, coating. primer and powder B. CERTIFICATONS: 1. City of Los Angeles, CA approved fabricator. 2. Quality Control Inspector qualified by the Los Angeles (California) Department of Building and Safety, Materials Control Section for fabrication with Medium Weight Steel 3. Miami Dade County Certificate of Competency for Structural Steel and Miscellaneous Metal Products and Assemblies. 4. City of Houston, TX approved fabricator. 5. City of Riverside, CA approved fabricator. 6. City of San Bernardino, CA approved fabricator. 7. County of Clark County, NV approved fabricator. 8. State of Utah Approved Fabricator. 9. NTA Listing Report PSC121902-22 for structural insulated panels. 10. Welders Certified to AWS D1.1. 11. AWS Certified Welding Inspector. 12. ASQ Certified Quality Manager/Organizational Excellence. 13. LEED AP. 14. PCI 4000 S Certified, Certification thru PCI for original equipment manufacturers (OEMs) to evaluate process on entire finish system to add powder coat over steel. 1.8 DELIVERY AND STORAGE Installer shall unload materials with necessary equipment (no hand unloading), store covered out of weather, and keep out of direct sun. The owner's representative shall inspect parts within 48 hours of delivery, compare with manufacturer's bill of material, and report any missing or non -conforming parts to manufacturer within this time. 1.9 LIMITED WARRANTY poll 0 VSTEEL SHELTERS by PorterCorp * Holland, MI * 49424 CSI Section 10 73 00 www.poligon.com * 800-354-7721 * fax 616-399-9123 Page 4 of 6