CORRESPONDENCE - PURCHASE ORDER - 9113293
/W 3 -loll SAFETY STORAGE INC. 855 N. 5th Street Charleston, IL 61920 Ph: (888) 345-4470 Fax: (217) 345-4428 http://www.safetystorage.com May 24, 2011 Errin Henggeler City Of Fort Collins PO Box 580 Fort Collins, CO 80522 Phone: 970-416-2320 Email: ehenggler@fcgov.com Ref: 2411 ER Dear Errin: Safety Storage, Inc., on behalf of its representative Jim Bath, is pleased to submit the following quotation for the manufacture of one (1) Factory Mutual (FM) Approved Model LF0810 Safety Storage Building equipped with the items you requested. The specifications for this building are attached for your review. The following quotation will be honored for a period of sixty (60) days from the date of this quote. LF0810 Bldg, Uni-Directional Fireshield, 2HR Fire Rated $12,460.00 Nominal Ext. Dimensions 101 X 8'W X 8'H (Optional items not �J 7, -included) -Includes 1 Door 60W X 80H (39 FT) Shelving,16" Deep, with 1" Lip, SS TOTAL PURCHASE PRICE $12,460.00 Freight Estimated Freight to Fort Collins, CO (does not include off-loading) $3,245.00 /ease See Page (4/ for Qpptional Accesso�s ries ,Not /nclutleal / +"�� 5 Freight and Off -Loading Charges, Arming of the Dry Chemical System, any Required Approval Fees and Taxes Are Not Included; Please refer to the attached Safety Storage, Inc. Terms & Conditions. Freight estimates are valid for 14 days only. All freight estimates include permits, pilot cars, and fuel surcharges. Because all loads are subject to fuel surcharges, rates may vary at time of shipment Lead Time: 8 to 10 weeks after approval. Allow up to 5 days for Delivery. This is an estimate only; lead time affected by project complexity and production backlog at the time of order. Deliver time varies depending on location and season. Delivery Terms are F.O.B. Origin — Prepaid & Added to Invoice. ,Please indicate shipping preference on your purchase order. (1) Please issue and mail your purchase order directly to: Safety Storage, Inc. P.O. Box 440 Charleston, IL 61920 A copy of the purchase order may be faxed to: Safety Storage, Inc. (217)345-4428 If you should have any questions regarding this quotation, please do not hesitate to contact Sales Representative: Jim Bath 1104 Snowberry Drive Golden, Colorado 80401 Phone (303) 763-8857 Fax (303) 763-8858 email jbath.psi@comcast.net Thank for your interest in Safety Storage products. We look forward to working with you on the successful completion of this project. Sincerely, SAFETY STORAGE INC. Eric Rienbolt General Sales Manager (2) SAFETY STORAGE BUILDING "LF" Series A free-standing, relocatable chemical storage and containment structure. The structure includes the following components for storage of flammable or combustible liquids and other hazardous materials. STANDARD FEATURES: • Factory Mutual System ("FM") Approved & Labeled. • Exterior Wall Construction: Weatherproof 2-hour fire -rated noncombustible construction, with multiple layers of UL Classified fire -resistive gypsum wallboard encased between interior galvannealed steel sheets & exterior welded heavy gauge steel sheets for maximum durability, weather resistance & rigidity. Gypsum wallboard layers are offset with overlapping joints for maximum fire -resistance. • Sump Wall Construction: Weatherproof 2-hour fire -rated noncombustible construction, same as exterior walls, utilizing interior & exterior continuously welded heavy gauge steel sheets for maximum spill containment protection. • Roof/Ceiling Construction: Weatherproof fire -rated membrane noncombustible construction, same as exterior walls, utilizing interior galvannealed steel sheets & continuously welded heavy gauge steel roof sheets for maximum durability and weather resistance. Roof/ceiling permanently attached to exterior walls. • 60' W x 80"H, Three-hour fire -rated double door(s), UL Classified & Labeled, equipped with UL Listed self-closer(s) and UL Listed exterior security lock(s) with keyless interior safety release lever(s). • Screened Air Vent(s): Air inlet vent(s) equipped with UL Classified & Labeled 3-hour rated fire dampers with louvers & screens to provide air flow. Dampers have a galvanized steel frame, curtain -type galvanized steel blades, and a UL Listed 1650F fusible link. • Building Base: Open channel construction for forklift and/or crane slings and under building inspections. • Internal Spill Containment Capacity: Minimum 30% of total storage capacity. Surpasses regulatory and Factory Mutual requirements for spill containment. • Interior Finish: High solids, chemical -resistant epoxy coating with a white aliphatic polyurethane topcoat. • Exterior Finish: High solids, chemical -resistant epoxy undercoat with a heat reflective white aliphatic polyurethane topcoat. • Four (4) Hold-down Brackets (structural steel angles) for bolting to purchaser's foundation for seismic and wind load anchoring. • Static Grounding System: One (1) exterior grounding connection, one (1) 8-foot long 5/8" diameter copper -clad steel grounding rod, one (1) #4AWG copper conductor, and grounding lug(s). • Signage: D.O.T. hazard classification placard with rust -proof aluminum holder & stainless steel clips; and pressure sensitive NFPA 704 Hazard Rating Sign(s). DESIGN LOADS: • Roof Snow Load: 40 psf • Wind Load: 110 mph, Exposure C • Floor Live Load: 500 psf • Seismic Condition: Zone 4 or Performance Category E (3) INCLUDED ITEMS: SHELVING (Adjustable, 16"D) Corrosion -resistant stainless steel adjustable shelving with clear zinc -coated supporting standards and brackets. Each shelf is 16" deep with a 1" lip on its front, back and side edges for secondary spill containment. Each shelf will support a uniformly distributed load of 80 psf. OPTIONAL ITEMS (Not Included) Price = $220.00 (Please note that this option is necessary if any other electrical accessory is taken) LOAD CENTER (Single Phase) UL Listed, 240/120V, single-phase load center (NEMA 3R) with circuit breaker(s) and main breaker. Price = $990.00 LIGHTING, INTERIOR (135W Lamp) (Explosion-Proofl Interior UL-Listed explosion -proof incandescent light fixture with a 135W lamp (120V, 1.25A, 1-Phase), rated for Class I, Division 1, Groups C & D, Hazardous Locations. Heavy-duty glass globe with a sealed heavy-duty aluminum housing and equipped with a protective metal guard. Equipped with an exterior UL Listed light switch (snap type) suitable for outdoor locations. Price = $2250.00 DRY CHEMICAL FIRE SUPPRESSION SYSTEM UL Listed & FM Approved pre-engineered system rated for Class A, B and C Fires. Fusible link detection for automatic actuation. Interior nozzle(s) for total flooding application. One (1) exterior UL Listed weatherproof audible alarm (120V, 0.1A, 1- Phase). Dry chemical agent storage cylinder (tank) and releasing device housed inside an exterior tamper -proof (key lockable) enclosure per the requirements of NFPA 17 (Standard for Dry Chemical Extinguishing Systems). System equipped with a means for remote annunciation. Automatic ventilation system shutdown (if applicable) upon system actuation. Price = $609.00 RAMP (Steel. 48"x 88") Access Ramp (48"W x 881) fabricated from 3/16" plate steel with 12GA formed side walls and protected with a "safety yellow" coating. Securely held in place with two 1/2" diameter inserts located in the door thresholds. Installation required by others. (4) CONCRETE I. cma.l. emat.,, t u. lm xama mnaaR cw.. v[tr4[ mq[t dJ. N d-gFMee b _m. Mrtltlue. m,WM[ Iw" eibew q[I ,ed N oNN R M wwsk. G[aek MI la,.. N-ery 000 µn ot 1 M1,[beYq yn ml ml.n 1v ED m Asrx AI!] are aw r Ieppu a ea e' ea e o o, y I s 14F- -beer enm u Mt e.er a x' (CL TO CL) el e e .a wMMI•^[ eaver wrct. r,I— mtnm mu. A (ANCHOR BOLTS) [ llxn- FeWtp .M bear m rob al ,mgtaeu i 'bell or II orw beri knte Wn[ fR .RR a nkn •meM. bgl,R [epa[ly tl iJ9 Rabb Pt 4 e. I t m°Rw�R wR 9_' - Buesn-91[e, [Ren .1 en emwl uneim,leee ,ell or .e[bee mnM rR Rob a Mr. aa.eb" emnq [[ee[Ry a faW es."S.`I;,�� ebbed et'll, Jb" ma, ea " cw z'b• mew be ,ee enmp.meq eygNgaea.iueb e Al .. m 1. be be. meal m or beq L.iq Re a. Mttxnl eels. T. CM il Core. nm.l, .1m be Snwln-T...l De.. A n.. a t la.-OO for r.,eeeif n vee. 1 cersnY mortal, mE mW,ee..f m.alct'an iWl e.eWRc nepl., u 0 IM lnl N.L.I M&I, C.d. Dock mc; Io.be1 be R In mewls eeln R e. y.ku,e. M: wt p.ta. SIMPSCN STRONG-TE SET HIGH 5TRENCTH EPOKY (ICBD ER-S279) WITH (1) A307 7/3'a ALL THREAD ROD ANCHOR BOLTS (AND HEX NUTS), WRH 7' MINMLPM EMBEDMENT 3'x Y. 1/2^ THCK ANGLE. 6^ LONG -S 7 0 EACH CORNER \ C4 X S.R. CHARNEL C") /4 O.C. EACH WAY In STCNE Y 2 1/4' Ct£AR Be a^ a^ 2'-0' MINIMUM' ll 6 MIL VAPOR BARRIER -OR TO FROST UNE DEPTH (WHCRfYERAs DRFATER) IICTR TNF uuR F CIF LJ PFAIMETER FOOH.NC OETNL ANCHOR ti 6^ _ x^ (Cl_ TO GL ANCHOR BOLTS) / --------------------------- ER EDGE OF SUB METER FOOTING SSI BUILDING k' + 24" (MAIN SLAB LENGTH) FOUNMTION PAD PLAN TOP OF SLAB RECOMMEND PRCHING, (FRONT � REAR), TO PREVENT WATER ACCUMULATION 1.125^ MIN. 'q;;ICK 44 LONOITUONAL SECTIO NON -SHRINK GROUT UNDER ANGLE BRACKET (TYP) CHAMFER AWAY FROM BRACKET AT 45' ANGLE 14 TURNED COWN BARS ® 12' O.C. CHAMPFER CL' MP) REBAR (TYP) NOTICE, EDGE OF MNN SUB " uxx rzxr al,aeR a mTa sIe HOLD-DOWN ANGLE YI/ (1) ANCHOR BOLT AS07 7/B^0 ANDIDRS 1YP a 4 CORNERS. WITH i EMBEDMENT JSNC SET EPD)CY RX¢ NIDWaE uro 'Y' 4 24" Oa.®ea,V il] MI (MAIN SIAB IWOTH) n la.n kt oI 1N[ .0 ICIQt IRE So= (H WE Ale S' M. N . W/ 1 - 2.Na MI YN. el IxAT '. vR YwlveenmW wba r..e a) AUP[IBIf LNa � ON A FM'IpR OF WEII aF ♦ wR wxevrc wwmRs e) mSlRxees wo svwlxe va uwuALTIRq's REW(AAREIFMS ILLUSTRATIVE SAMPLE HOLD-DOWN ANGLE I_ !Y1 TRANVER SOMM U THESE FOUNDATION DETAILS ARE ILLUSTRATIVE ONLY, AND SHALL NOT BE USED AS A BASIS FOR CONSTRUCTION OF AN ACTUAL FOUNDATION. THE FOUNDATION, ANCHOR BOLT SIZE, AND EMBEDMENT SHALL BE DESIGNED BY AN ENGINEER, HIRED BY THE OWNER OR CONTRACTOR, AND LICENSED IN THE STATE WHERE THE BUILDING IS TO BE SITED. wrrnRCAr ©raw n vran N9A4R IAA 14 AL@eJ RRS6R1ip IflIL LOATIYdMB ARH FaT F 88 RdIAtlCLCPO MR IAT NIPF65E. A QMI GA N PLfl RIIIMn rR1nL DdAV24®1ID15IRR 9aRIQ. MC en.w u+w 1111MATIVE SAN LE FOUNDATION PLAN ob m FOR 1—MT BRACKET W/ SET fm U-) Corporate Profile Safety Storage Incorporated From its start, Safety Storage, Inc. has been the industry leader designing high quality, cost-effective secondary containment Hazmat storage and compaction products meeting the latest compliance codes for the handling, use, containment and compaction of hazardous materials. In 1982, seeing rapidly expanding federal, state and local regulations and changing building, fire and environmental codes, SSI responded with the industry's first pre-engineered, pre -fabricated, factory - built, non-combustible hazardous material storage unit. In 1999 SSI merged with Haz-Stor. The combined company offers the widest variety of pre-engineered secondary containment lockers and customized buildings available for use in and around an existing factory. Between those major milestones, SSI has introduced or offered a wide range of pre-engineered units in many sizes with sophisticated options and applications. A few are: • 1985 The first explosion -resistant construction for storage and dispensing • 1988 The first 2-hour fire -rated building Classified construction • 1992 The first 4-hour fire -rated building Classified construction • 1994 Drive on decontamination sump for vehicles dispensing pesticides • 1995 CTI brand hazwaste compaction systems and drum crushers acquired • 1996 Modular units to 1500 sq. ft. to accommodate facilities expansions • 1999 Buildings used to house and protect paint mixing equipment and operations • 2008 The most corrosion resistant code compliant building ever, DualSafe is launched. Safety Storage's Strengths — Today and in the Future • SSI is the only manufacturer with a nationwide local representative network to meet in person with you and meet your needs. • SSI is the most compliant manufacturer in the industry. We are constantly reviewing and updating our designs to meet the latest codes and requirements. • SSI works directly with you on site, identifying your needs, recognizing your site constraints, finding you standard or custom -engineered special purpose buildings, and evaluating alternatives to satisfy you and state and local authorities using Regional Sales Managers and factory -trained Sales Professionals. • SSI assembles professional technical packages, price proposals, and engineered drawing packages necessary for acceptance and approval by insurance, building, and fire officials prior to delivery. • SSI's factories apply state-of-the-art manufacturing practices, employ AWS certified welders, and host independent 3' party inspectors resulting in consistent quality and cost savings. • SSI offers you complete product liability insurance and warranties which support your needs for safe, reliable, cost-effective, compliant secondary containment building systems (6) SAFETY STORAGE, INC. Terms and Conditions 1) FOB POINT: Shipping Point (Hollister, CA or Charleston, IL) 2) FREIGHT CHARGES: Safety Storage, Inc. quotations provide "estimated" freight charges. Unless otherwise noted on your purchase order, these charges will be prepaid and added to the invoice. 3) TERMS: 25% down, due upon placement of an order. Safety Storage, Inc. will invoice for the down payment (due upon receipt), ifdeposit check is .or received with the purchase order. The balance, including freight charges, will be invoiced upon shipment and is due NET 30 days. 4) PURCHASE ORDER: Your order will be added to our production schedule upon credit approval and our receipt of your purchase order, 25% down payment, and signed diagram. Please issue your purchase order directly to: Safety Storage, Inc. You may fax a copy of Me purchase 855 N. 5th Street order to Safety Storage, Lie. at 217-345-4428 Charleston, IL 61920 Attn: Kara Smith 5) REMIT TO ADDRESS: Safety Storage, Inc. P.O. Box 49093 San Jose, CA 95161 6) CONTACT NAME: Delivery contact time and telephone number(s) must be included on the order. 7) PRODUCTION TIME: Orders will be scheduled for production on a first -come, first -served basis. Please call for delivery date. 8) CREDIT APPROVAL: Credit Approval is required on all orders. 9) ORDER CONFIRMATION: The estimated completion date of your order will be provided after receipt and processing of the order. Note: orders requiring state or local approvals are placed into the production schedule after receipt of such approvals. 10) INTERNATIONAL ORDERS: the following must be received prior to processing of your order. Unless otherwise noted below, all terns and conditions listed above remain valid: a. Original Irrevocable Letter of Credit submitted to Comerica Bank. It. Irrevocable Letter of Credit must be in an acceptable form to Comerica Bank. C. The expiration date of the Irrevocable Lever of Credit must be no less than six months (6 mos.) from the date the Irrevocable Letter of Credit is received by both Comerica Bank and Safety Storage, Inc. d. Payment terms are 25% down, Net 10 days. Please note that funds must be deposited directly to Safety Storage, Inc.'s bank account using the following information: Name of Bank: Comerca Bank Address: 333 West Santa Clara St. San Jose, CA 95113 ABA#: 121137522 Account#: 1890609769 Telephone#: 408-556-5238 Fax #: 408-556-5395 Bank Contact Name: Charles McCarroll 11) REGULATORY AGENCY APPROVAL: Where applicable, third party approval maybe required on `closed construction" (i.e., insulated or fire - rated) units. Associated fees are not typically included in the quotation. Prior to purchase order submission, the customer is responsible for contacting the local jurisdiction to ascertain the specific requirement. If local jurisdiction deems that third party approval is not required, documentation From that agency must be provided with the purchase order. If, however, third party approval is required, estimated fees will be provided by your Safety Storage, Inc. Field Engineer and must be included on your purchase order. Upon placement ofan order, Material Safety Data Sheets (MSDS) for each of the chemicals being stored in the Safety Storage building(s), quantities and container size of each chemical, and a plot plan illustrating the location of the Safety Storage building(s) relative to existing structures and/or property lines will be required to determine the occupancy classification (112, H3, H4, H7, SI, etc). As part of the plan review, the reviewing agency may require that additional equipment be added to the unif(s). If this should occur, the price for these additional item(s) will be quoted to the customer upon receipt of the approval and a revised purchase order will be required to proceed with the order. An estimated completion date will be provided after receipt ofthe third party approval (estimate 10 to 14 weeks). In addition, the reviewing agency may require that additional equipment be added to the unit(s) during the plan review process. The price for these additional items will be quoted to the customer upon receipt of the plan review and a revised purchase order maybe required to proceed with processing of the order. Note: orders requiring state or local approvals are placed into the production schedule after receipt of such approvals. 12) DELIVERY ACCEPTANCE/STORAGE: If, for any reason, the customer is unable to accept delivery of the unit(s) upon production completion and notification from Safety Storage, Inc., the customer agrees to accept title of the building(s), be invoiced for the building(s) and pay the invoice terms. If, after two (2) weeks from the date of initial invoice, the customer is unable to take delivery of the building(s), storage charges of $500.00 per week, per building accrue and will be invoiced weekly. 13) DRY CHEMICAL FIRE SUPPRESSION SYSTEM: Systems must be shipped unarmed to preclude accidental discharge during transportation. It is the customer's responsibility to initiate a start-up and regular maintenance program for each building by contacting the nearest Representative of the fire suppression system manufacturer. 14) DOCUMENTATION & PERMITTING: A certified engineering package consisting of detailed schematics and structural calculations, necessary for permitting, are available for an additional charge, subsequent to order placement. 15) OFFLOADING: All Safety Storage, Inc. buildings are shipped on open flatbed trailers. Offloading the building(s) at the customer's site is the responsibility of the customer. Upon order entry, offloading instructions will be provided to enable you to arrange offloading equipment of the proper type and capacity. NOTE: Offloading arrangements should not be made prior to notification from Safety Storage, Inc.'s Corporate Transportation �7� Department as to actual delivery date of the unit(s). Safety Storage, Inc. will not be responsible for any incurred offloading charges as the result of an unauthorized arrangement. 16) INSTALLATION: Installation (anchoring, electrical connections, plumbing connections, etc.) of Safety Storage, Inc. buildings are the responsibility of the customer. 17) PRELIMINARY LIEN: Safety Storage, Inc. reserves the right to pre -lien orders to assure payment. 18) DEMURAGE: In the event of any delays in offloading the Safety Storage, Inc. building(s) at the delivery site caused by the customer's inability to have the site prepared, the customer will be responsible for charges assessed by the transporting company. 19) CHANGE ORDERS: Safety Storage, Inc. will assess a minimum S500 change order fee to make customer requested changes to a product that has been released to engineering prior to the change notification. Safety Storage, Inc. will assess a minimum SI,000 change order fee to make customer requested changes to a product that has been released to production prior to the change notification. The aforementioned charges are over and above the cost to implement the requested changes. Changes may affect promised delivery dates. 20) RESTOCKING/CANCELLATION FEES: Safety Storage, Inc. will assess a minimum of25% of order total for reslocking/cancellation fees (dependent other costs incurred). Safely Storage, Inc. reserves the right to determine applicable cancellation fees for custom orders. 21) SECURITY: In the event that the customer does not pay the balance when due, or breaches any other terns of the agreement, Safety Storage, Inc. may demand the entire unpaid balance to be paid immediately and, as provided by law, commence any legal action for collection of the balance due. Safely Storage, Inc. may also pursue any other legal action deemed necessary or appropriate with respect to the account. The customer agrees to pay reasonable collection fees of not less than twenty percent of the entire balance and late charges, court costs and all other costs of collection. 22) LATE CHARGES: It is understood and agreed that all charges are due and payable in full by the 30th day aRer invoice date. Any account not paid in full within thirty (30) days of invoice date is delinquent and will be assessed a service charge of 18%per annum, or the maximum allowable by law. 23) TAXES: All applicable sales or use taxes are the responsibility of the customer; these taxes are not included in the price quoted. Applicable sales or use taxes should be added to the purchase order. If tax exempt, please supply a copy of your Tax Exempt Certificate with your purchase order. 24) LIMITED WARRANTY a. Limited General Warranty - Your Safety Storage, Inc. ("SSI") Building is warranted to you as the original purchaser. Defects must be reported to Safety Storage, Inc.'s Customer Service Department within sixty (60) days of Product delivery. Limited Structural Warranty - Safely Storage, Inc., will warrant structural components (e.g., load -bearing walls, floor supports, sump structure and roof) for a period often (10) years from the date of purchase. SSI will replace or repair, at SST's option, within the warranty period, any structural component which, in its opinion is defective and has not been tampered with, modified, subjected to an accident, misuse or abuse, neglect, subjected to use in extreme conditions not expressly communicated to Safely Storage, Inc., or not maintained, inspected and tested in accord with the SSI Maintenance Manual shipped with the product. At the option of the SSI Customer Service Department, a structural component shall be replaced or repaired at the customer's site using factory personnel or outside contractors under SST's direction. This limited warranty does not apply to the installation of optional equipment by others. If the product must be returned to SSI or its authorized subcontractor for warranty repair work, all installed equipment not covered under warranty must be removed (by others) prior to shipment. Limited Purchased Products or Pans Warranty - Items that are not manufactured but purchased by SSI are warranted against defects resulting from the original manufacturer's fabrication process or parts for one (1) year from the date of delivery. Such items include but are not limited to: switches, lights, electrical boxes, air conditioners, heaters, fan motors, dry chemical fire protection equipment, fusible links, door closures, door locks, electrical relays, thermostats, pressure relief valves, shut-off valves, ere. Such items should be returned to SST's Hollister, California, factory with the pior approval of the SSI Customer Service Department. Evaluation of each reported defective pan will be made by the original manufacturer or agent thereof and their judgment shall be final. Upon Safety Storage, Inc.'s receipt of the original receipts, the Customer will be reimbursed for the postal charges, duties and insurance where applicable. SSI will replace or repair, at SST's option, any purchased product or part which, in its opinion is defective and has not been tampered with, modified, subjected to an accident, misuse or abuse, neglect, subjected to use in extreme conditions not expressly communicated to Safety Storage, Inc., or not maintained, inspected and tested in accord with the SSI Maintenance Manual shipped with the product. At the option of the SSI Customer Service Department, a purchased product or pan shall be replaced or repaired at the customer's site using factory personnel or outside contractors under SST's direction. This limited warranty does not apply to the installation of optional equipment by others. If the product must be returned to SSI or its authorized subcontractor for warranty repair work, all installed equipment not covered under warranty must be removed (by others) prior to shipment. d. These limited warranties are the original purchaser's exclusive warranties and replace all other warranties or conditions, expressed or implied. e. Items Not Covered By Warranty - Safety Storage, Inc., does not warrant uninterrupted operation ofbuilding systems. Any technical support provided for a product under warranty, such as telephone assistance with "how to" questions and those regarding building and product setup and installation will be provided without warranties ofany kind. F. Warranty Work: • Before Safety Storage, Inc., will approve return ofany products under warranty, the Purchaser must ensure that the product(s) are free ofany legal obligations or restrictions and obtain written authorization from the legal owner. • Prior to any on -site warranty work by SSI or its authorized subcontractor(s), the Purchaser will provide sufficient, free, and safe access the Purchaser's facilities to permit warranty repair(s). • Safely Storage, Inc., is responsible for the loss of, or damage to, warranted products while they are in SSI's possession. While products are in transit, any damage or loss will be the responsibility of the transporter. 25) DISCLAIMER AND LIM ITATION OF DAMAGES: Except as stated in Safety Storage, Inc.'s "Limited General Warranty', "Limited Structural Warranty" and "Limited Purchased Products or Pans Warranty", SSI makes no other warranties whatsoever, whether express or implied, including the warranties of merchantability and fitness for particular purpose. SSI does not assume or authorize any person to assume for it any liability in connection with the damage. Under no circumstances, shall SSI be liable for any special, incidental, consequential, or indirect damage. SSI's maximum liability for any direct damages shall be limited to the purchase price paid by the customer for the particular product. Under no circumstances will SSI be liable for any third party claims against the original purchaser. �8�