HomeMy WebLinkAboutRESPONSE - BID - 7195 CONCRETE REQUIREMENTSCITY OF FORT COLLINS
BID PROPOSAL
BID #7195
CONCRETE REQUIREMENTS
BID OPENING: February 2, 2011, 3:00 p.m. (our clock)
WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR
SAND AND WATER MIX, NON -YIELDING BACKFILL, SLURRY CONCRETE AND READY -
MIX CONCRETE PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS.
SPECIFICATIONS AND APPROVED VENDORS:
The City of Fort Collins Light and Power Utility requires all firms supplying Ready Mix Concrete,
Slurry Concrete, Non -Yielding Backfill or Sand and Water Mix to conform to the attached
Material Specification #366-501.
An important aspect of the specifications is Section 7.0 Requirements to be an Approved
Supplier (prequalification). Due to the extensive test data, certification of the supplier's plant,
and references requested, only those Suppliers listed on Appendix A Approved Suppliers
Specification 366-501 may bid these requirements. All Approved Suppliers must be located
within 10 miles of Fort Collins' urban growth area.
Firms wishing to be approved can submit all required documentation for approval at any time.
Light and Power and Purchasing personnel will analyze the documentation and determine the
firm's status of approval. The firm will be notified immediately of their status, but will not be
placed on the approval list until material requirements are bid again.
The full set of Material Specifications is attached. Section 1.1, Scope, pertains to each material
(Non -Yielding Backfill, Ready Mix Concrete, etc.) and firms can bid only on the material they are
approved to supply in Appendix A. Bids submitted for unapproved materials will be disqualified.
Delivery Time: Contractor must deliver concrete a minimum of 2 hours after the order is called
in. City will give contractor as much time as possible for large deliveries.
Admixtures : Due to the detailed specifications for these materials, there will be no adders bid
for admixtures.
Bid Award:
The City may elect to award each material individually or as a total package, whichever is in the
best interest of the City. Additionally, each material may be split between two or more Bidders.
Contractor must enter into the attached services agreement and provide the required
insurance. This agreement is effective for one year from the date on the service agreement. In
addition, at the option of the City, the Agreement may be extended for additional one year
periods not to exceed four (4) additional one year periods. Renewals and pricing changes shall
be negotiated by and agreed to by both parties. The Denver Boulder Greeley CPIU published by
the Colorado State Planning and Budget Office will be used as a guide. Written notice of
renewal shall be provided to the Service Provider and mailed no later than ninety (90) days prior
to contract end.
3
SA rev03/10
ESTIMATED OTY. DESCRIPTION UNIT
1. 1,800 cu. yds. Sand and Water Mix $ _6 /cy
.per the Specifications of Attachment D
2. 3,500 cu. yds. Non -yielding Backfill $ J3. gO_/cy
per the Specifications of Attachment A
3. 1,000 cu. yds. Slurry Concrete $ —7 1, L iJ /cy
per the Specifications of Attachment C
4. 130 cu. yds. Ready -Mix Concrete $ 00 jcy
per the Specifications of Attachment B
DELIVERY CHARGES:
Over 5 miles from urban growth area of Fort Collins, non -mountains, ADD $ per load
mile.
Over 5 miles from urban growth area of Fort Collins, in mountains, ADD $ per load
mile.
Minimum load is _Cy.
Additional char es if less than minimum load is required will be
$ cy/load.
BIDDER'S STATEMENT:
I certify that my firm has been approved to supply the materials above and further certify that all
materials supplied do now and will, for the term of this award, comply with the attached Material
Specification #366-501. 1 understand any deviation from the Specifications can disqualify my bid
for that material.
FIRM NAME: LAFRRGE //'�NC/Z�7EE
c,7< �7
ADDRESS /900 /\/ �r I ( /C L'
PHONE/FAX 270 - L107- 3 UU 970- L/6)7- -CX
BY: tl i�YLi-1 G e co- e_L AQy Scf E5 �ep•
(Signature) (Printed) (Title)
4
SA rev03/10
P
FARGE
RTH AMERICA
Mix Identification No.:
GGOOKG9N
LCM Batch Code:
Design Strength:
Mix Description:
0, Sand, NAE
Typical Usage:
Lafarge N.A. Lab No.:
Mix Proportions:
ASTM
Design Weights
Materials:
Type or Size
Standard
per Cubic Yard
Total Cementitious
0 lb.
Cement
1-2
C-150
0 lb.
SCM
Class C
C-618
0 lb.
Coarse Aggregate
57/67
C-33
0 lb.
Int. Aggregate
# 8
C-33
0 lb.
Fine Aggregate
Sand
C-33
2705 lb.
AEA
C-260
oz.
WRA
A
C-494
4 oz/cwt
MRWR
A
C-494
OZ/cwt
HRWR
F
C-494
oz/cwt
Water
City
C-94
3700 lb. 444.2 gal.
The above weights are based upon aggregates in a saturated, surface dry (SSD) condition. Batch plant corrections must be
made for moisture in aggregates. Mix proportions may be adjusted in accordance with 301-05, section 4.2.3.5
Physical Properties of Mixture:
Slump 8 - 10 in.
Air Content /,
Unit Weight 130 pcf
Yield 27.17 cu. ft.
Compressive Strength (psi):
3 Day 7 Day 28 Day 56 Day
LAFARGE North America
J. Scott Keim, P.E.
Quality Assurance Manager
Front Range Concrete Division
Jow
LAFARGE
NORTH AMERICA
Mix Identification No.:
JC10DC7C
Old Mix Identification No.:
Design Strength:
100
Mix Description:
Flowfill
Typical Usage:
Excavations
Lafarge N.A. Lab No
Mix Proportions:
ASTM
Design Weights
Materials:
Type or Size
Standard
per Cubic Yard
Cement
III
C-150
80 lb.
SCM
Class C
C-618
0 lb.
Coarse Aggregate
57/67
C-33
1647 lb.
Int. Aggregate
C-33
lb.
Fine Aggregate
Sand
C-33
1698 lb.
AEA
C-260
oz.
W RA
A
C-494
oz.
MRWR
A
C-494
oz.
Water
City
C-94
332 lb.
Special Material
39.9 gal.
The above weights are based upon aggregates in a saturated, surface dry (SSD) condition. Batch plant corrections must be
made for moisture in aggregates. Mix proportions may be adjusted in accordance with 301-05, section 4.2.3.5
Physical Properties of Mixture:
Slump
7-9
in.
Air Content
6 - 10
%
Unit Weight
133.8
pcf
Yield
28.08
cu. ft.
Water/Cement Ratio
4.15
Initial Time of Set
hr/min
Compressive Strength (psi):
(Estimated) 3 Dav
7 Dav
28 Day 56 Dav
100
LAFARGE North America
) Z"�te� —�-"O�
J. Scott Keim, P.E.
Quality Assurance Manager
Front Range Concrete Division
P
FARGE
RTH AMERICA
Mix Identification Code:
Old Mix Identification Code:
Design Strength:
Mix Description:
Typical Usage:
Lafarge N.A. Lab No.:
Mix Proportions:
Materials:
Cement
SCM
Coarse Aggregate
Int. Aggregate
Fine Aggregate
AEA
W RA
MRWR
HRWR
Water
MC20DC2J
2000
2000, 57/67, AE, MUNICIPAL
ASTM
Design Weights
Type or Size
Standard
per Cubic Yard
1-2
C-150
195 lb.
Class F
C-618
181 lb.
57/67
C-33
lb.
# 4
C-33
1882 lb.
Sand
C-33
1147 lb.
C-260
oz.
A
C-494
19 oz/cwt
A
C-494
oz/cwt
F
C-494
oz/cwt
City
C-94
374 Ib. 44.9 gal.
The above weights are based upon aggregates in a saturated, surface dry (SSD) condition. Batch plant corrections must be
made for moisture in aggregates. Mix proportions may be adjusted in accordance with 301-05, section 4.2.3.5
Physical Properties of Mixture:
Slump 6-8 in.
Air Content 1 - 4 %
Unit Weight 138.7 pcf
Yield 27.13 cu. ft.
Water/Cement Ratio 0.99
Compressive Strength (psi):
(Estimated) 3 Dav
LAFARGE North America
J. Scott Keim, P.E.
Quality Assurance Manager
Front Range Concrete Division
7 Day 28 Day 56 Day
2240 3200
LAFARG E
NORTH AMERICA
Mix Identification Code:
Old Mix Identification Code
Design Strength:
Mix Description:
Typical Usage:
Lafarge N.A. Lab No.:
Mix Proportions:
GE40DC5J
4000
4000, 57/67, AE, STANDARD
General Use, Exterior Slabs
ASTM
Design Weights
Materials:
Type or Size
Standard
per Cubic Yard
Total Cementitious
590 lb.
min.
- Cement
1-2
C-150
80 %
min.
SCM
Class C
C-618
20 %
max.
Coarse Aggregate
57/67
C-33
58-60 %
Int. Aggregate
# 8
C-33
Fine Aggregate
Sand
C-33
40-42 %
AEA
C-260
3.5 oz.
W RA
A
C-494
3-7 oz/cwt
MRWR
A
C-494
oz/cwt
HRWR
F
C-494
oz/cwt
Water
City
C-94
267 lb.
32.1 gal.
The above weights are based upon aggregates in a saturated, surface
dry (SSD) condition. Batch plant corrections must be
made for moisture in aggregates. Mix proportions may be adjusted in accordance with 301-05, section 4.2.3.5
Physical Properties of Mixture:
Slump
2-4
in.
Air Content
5-8
% Entrapped
Unit Weight
141.5
pcf
Yield
27.14
cu. ft.
Water/Cement Ratio
0.45
Compressive Strength (psi):
(From Field Data)
3 Day
7 Dav
28 Day
56 Day
3720
4850
LAFARGE North America
J. Scott Keim, P.E.
Quality. Assurance Manager
Front Range Concrete Division