Loading...
HomeMy WebLinkAboutRESPONSE - BID - 7196 WATER METERSi AT10NAL METER AND AUTOMATION, INC_ 7220 S Fraser St, Centennial, CO 80112 Tel: (303) 339-9100 Fax: (303) 649-1017 January 14, 2011 City of Fort Collins Purchasing Division 215 N. Mason St., 2°d Floor Fort Collins, CO 80522 Re: BID #7196 Water Meter Dear Director of Purchasing and Risk Management, National Meter and Automation, Inc. is pleased to submit the enclosed bid for water meters. We are the exclusive Colorado distributor for water meters manufactured by Badger Meter, Inc. As a certified Tier 1 distributor, we can provide the City with customer support, local inventory, delivery, and technical assistance. We are the largest Badger Meter distributor in the United States and have the most experienced staff of any water works distributor in the State of Colorado. We will be there for the City to help resolve any meter issues. All meters quoted in our response to Bid#7196 meet or exceed the meter specifications of the City of Fort Collins and can be found on the City's approved list. In addition, our meters exceed the appropriate American Water Works Association standards for each size and type of meter. In our bid packet you will find the pricing sheets and also technical information on each meter proposed. Additional information can be found by going to our web site www.mnaai.com and clicking on the Badger Meter link. Thank you for your consideration of our bid. For questions or additional information, please feel free to contact me (303)478-8163 or through email jterrygnmaai.com. erely, 7� y L. Terry, Jr. National Meter and Automation, Inc. Sales Support Manager RecordallO Size 3/4" (DN 20mm) Technical Cold Water ANSUNSF Standard Bronze Disc Meter 61 Certified, Annex G Brief DESCRIPTION Badger Meter offers the Recordall Disc meter in Cast Bronze and a Low Lead Alloy. The Low Lead Alloy (Trade Designation: M35 LL) version complies with ANSIINSF Standard 61, Annex G and carries the NSF-61 Mark on the housing. All components of the Low Lead Alloy meter, i.e., disc, chamber, housing, seals, etc., comprise the certified system. APPLICATIONS: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. OPERATION: Water flows through the meters strainer and into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register.The follower magnet isconnected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register dial face. . OPERATING PERFORMANCE: The Badger® RecordalP Disc meters meet or exceed registration accuracy for the low floor rates (95%), normal operating flow rates (100 t 1.5%), and maximum continuous operation flow rates as specifically stated by AWWA Standard C700. CONSTRUCTION: BackjerRewrdaMDiscmeterconsMxfti whichcor om with ANSI/AW WA standard C700, ohs of three basic components: meter housing, measuring chamber, and permanently sealed register. The water meter is available in bronze and Low Lead Alloy with externally -threaded spuds. A corrosion -resistant thermoplastic material is used for the measuring chamber. To simplify maintenance, the register, measuring chamber, and strainer can be replacedwithout removingthe meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of parts among like -sized meters also minimizes spare parts inventory investment. The built-in strainer has an effective straining area of twice the inlet size. MAGNETIC DRIVE: Direct magnetic drive, through the use of high - strength magnets, provides positive, reliable and dependable register coupling forstraight-reading, remote orautomatic meter reading options. SEALED REGISTER:The standard registerconsistsof astreight-reading odometer -type totalization display, 3600 test circle with center sweep hand and flow finder to detect leaks. Register gearing consists of self- lubricating thermoplastic gearsto minimize friction and provides long life. Permanently sealed; dirt, moisture, tampering and lens fogging problems are eliminated. Multi -position register simplifies meter installation and reading. Generator -type remote reading and automatic meter reading systems are available for all Recordall Disc meters. All reading options are removable from the meter without disrupting water service. TAMPER -PROOF FEATURES: Customer removal of the register to obtain free water can be prevented when the optional tamper detection seal wire screw or T'OR)(®tamper resistant seal screw is added to the meter. Both can be installed at the meter site or at the factory. MAINTENANCE: Badger Recordall Disc meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. As an alternative to repair by the utility, Badger offers various maintenance and meter component exchange programs to fit the needs of the utility. CONNECTIONS: Tailpieces/Unions for installations of meters on various pipe types and sizes, including misaligned pipes, are available as an option. 3 Badger Meter e Model 35 SPECIFICATIONS Typical Operating 3/4-35 GPM (.17 to 7.9 m3/hr) Range (100% t 1.5%) Low Flow 3/8 GPM (.085 m3/hr) (Min. 97%) Maximum 25 GPM (5.7 ms/hr) Continuous Operation Pressure Loss 5 PSI at 25 GPM at Maximum (.37 bar at 5.7 m'/tlr) Continuous Operation Maximum Operating 80°F (26°C) Temperature Maximum Operating 150 PSI (10 bar) Pressure Measuring Element Nutating disc, positive displacement RegisterType Straight reading, permanently sealed magnetic drive standard. Remote reading or Automatic Meter Reading units optional. Register Capacity 10,000,000 Gallons, 1,000,000 Cubic Feet, 100,000 e. 6 odometer wheels. Meter Connections Available in bronze and thermoplastic to fit 3/4' spud thread bore diameter sizes. See table below. METER SPUD AND CONNECTION SUES size 'L' Designation x Laying Length '8' Bore Dta Coupling Nut and Spud Thread Tailpiece Pipe Thread (NPT) 3/4x 7%' 314' 1'(3/4') 3/4' 3l4' x 9' 3/4' 1' (3/4') 3/4' 3/4' xl' x 9' 3/4' 11G' (1-) 1' Meter Housing Housing Bottom Plates Measuring Chamber Disc Trim Strainer Disc Spindle Magnet Magnet Spindle Register Lid and Shroud Generator Housing MATERIALS Cast Bronze, Low Lead Alloy Bronze, Cast Iron, Low Lead Alloy Thermoplastic Thermoplastic Stainless Steel, Bronze Thermoplastic Stainless Steel Ceramic Stainless Steel Thermoplastic, Bronze Thermoplastic RD-T 3/4 1a10 PRESSURE LOSS CHART Rate of Fbm to Gal = per K&v i to loo ACCURACY CHART Rate or rbK m Gaotms par Mkwm la _ _ to - - - _ 'OD A B C D APPROX. METER METER LAYING HEIGHT HEIGHT CENTERLINE SHIPPING SIZE MODEL LENGTH REG. / RTR GEN. BASE WIDTH WEIGHT 5/; 35 71/2 51/; 65/8 15/a" 5- 51/p lb. (20mm) (190mm) (133mm) (168mm) (41mm) (127mm) (2.5kg) 3/; 35 9" 51/; 65/8 15/8 5° 5% lb. (20mm) (229mm) (133mm) (168mm) (41mm) (127mm) (2.6kg) 3/," x 1" 35 9" 5'/; 65/8 15/B 5- 6 Ib. (20mm) (229mm) (133mm) (168mm) (41mm) (127mm) (2.7kg) Sweep Hand Registration MODEL GALLON cu.F . cu. METER M35 10 1 .1 g 35 ' s a ® Y me,m o O = 7 Gallons 3� 'am 35 -9 35 5 Fm .7 Cubic Feet" .3 Please see our website at OUD www.badgermeter.com for speck contacts. CoMigM 2010, Badger Meter, br- All rights reserved RTRe and Recordalie are registered trademark of Badger Meter, Inc. TORX' Is a registered tradema* of Camcar. Division of Textron, Inc. Due to continu = researck product enprovertm is and enNummertls, Badger Meter reserves fhe dgtt to cha W product or system spediCaf l— widaA nofioe, except to the extent an auft9andutg o-b-hral obfigabon exists. Badger Meter P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876-3837 / Fax: (888) 371-5982 www.badgermeter.com ReCOrdallO Size 1" (DN 25mm) C ;� � MW- Cold Water ANSUNSF Standard Bronze DISC Meter 61 Certified, Annex G Brief DESCRIPTION Badger Meter offers the Recordall Disc meter in Cast Bronze and a Low Lead Alloy. The Low Lead Alloy (Trade Designation: M70 LL) version complies with ANSI/NSF Standard 61, Annex G and carries the NSF-61 Mark on the housing. All components of the Low Lead Alloy meter, i.e., disc, chamber, housing, seals, etc., comprise the certified system. APPLICATIONS: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. OPERATION: Water flows through the meter's strainer and into the measuring chamber where if causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register.The follower magnet is connected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register dial face. OPERATING PERFORMANCE: The BadgerRecordall Discmeters meet or exceed registration accuracy for the low flow rates (95%), normal operating flow rates (100 t 1.5%), and maximum continuous operation flow rates as specifically stated by AW WA Standard C700. CONSTRUCTION: Badger Recordall Disc meter construction, which complies with ANSI/AWWA standard C700, consists of three basic components: meter housing, measuring chamber, and permanently sealed register. The water meter is available in bronze and Low Lead Alloy with externally -threaded spuds. A corrosion -resistant thermoplastic material is used for the measuring chamber. To simplify maintenance, the register, measuring chamber, and strainer can be replaced without removing the meter housing from the installation. Nochange gears are required for accuracy calibration. interchangeability of parts among like -sized meters also minimizes spare parts inventory investment. MAGNETIC DRIVE: Direct magnetic drive, through the use of high - strength magnets, provides positive, reliable and dependable register coupling forstraight-reading, remote or automatic meter reading options. SEALED REGISTER: The standard register consists of a straight -reading odometer -type totalization display, 360' test circle with center sweep hand and flow finder to detect leaks. Register gearing consists of setf- lubricating thermoplastic gearsto minimize friction and provides long life. Permanently sealed; dirt, moisture, tampering and lens fogging problems are eliminated. Multi -position register simplifies meter installation and reading. Generator -type remote reading and automatic meter reading systems are available for all Recordall Disc meters. All reading options are removable from the meter without disrupting water service. TAMPER -PROOF FEATURES: Customer removal of the register to obtain free water can be prevented when the optional tamper detection seat wire screw or TORX® tamper resistant seal screw is added to the meter. Both can be installed at the meter site or at the factory. MAINTENANCE: Badger Recordall Disc meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient ration. As an aftemative to repair by the utility, Badger offers various maintenance and meter component exchange programs to fit the needs of the utility. CONNECTIONS: Tailpieces/Unions for installations of meterson various pipe typesand sizes, including misalignedpipes, are available as an option. Badger Meter m Model 7C SPECIFICATIONS Typical Operating 1 1/4-70 GPM (.28 to 16 m3/hr) Range (100% m 1.5%) Low Flow 3/4 GPM (.17 m'/hr) (Min. 95%) Maximum 50 GPM (11.3 m'/hr) Continuous Operation Pressure Loss 6.5 PSI at 50 GPM at Maximum (.45 bar at 11.3 m3/hr) Continuous Operation Maximum Operating 80°F (26'C) Temperature Maximum Operating 150 PSI (10 bar) Pressure Measuring Element Nutating disc, positive displacement ReglsterType Straight reading, sealed magnetic drive standard. Remote reading or Automatic Meter Reading units optional. Register Capacity 10,000,000 Gallons, 1,000,000 Cubic Feet,100,000 m'. 6 odometer wheels. Meter Connections Available in bronze and thermoplastic to fit 1' (DN 25mm) spud thread bore diameter sizes. See table below. METER SPUD AND CONNECTION SIZES Size 'L' "B' Coupling Nut Tailpiece Designation x Laying Bone and Pipe Thread Length Dta. spud Thread (NP ) 1' x 10 3/4' 1' 1 1/4' (1') 1' MATERIALS Meter Housing Cast Bronze, Low Lead Alloy Housing Bottom Plates Bronze, Cast Iron, Low Lead Alloy Measuring Chamber Disc Trim Strainer Disc Spindle Magnet Magnet Spindle Register Lid and Shroud Generator Housing Thermoplastic Thermoplastic Stainless Steel, Bronze Thermoplastic Stainless Steel Ceramic Stainless Steel Thermoplastic, Bronze Thermoplastic RD-T 1 10-te PRESSURE LOSS (MART Ram of Fbw, in GoDons per MkvAa 10 .. .. — ..1100 — .... — ...1000 a m is a 6s to s ACCURACY CHART Ram of Fbw In G>,aRom per Moons ID le tooa A A A t 4 6 1 rs a 4/ 10 A B C D APPROX. METER METER LAYING HEIGHT HEIGHT CENTERLINE SHIPPING SIZE MODEL LENGTH REGJRTR GEN. TO BASE WIDTH WEIGHT 1. 70 10 3r4' 6 1/2' 7 7/8' 2 5116' 7 314' 11 1/2 Ib. (25mm) (273mm) (165mm) (200mm) (59mm) (197mm) (5.2kg) Sweep Hand Registration MODEL I GALLON CU.Ff. CU. METER M707 10 1 .1 RTFP and Recordall' are registered trademarks of Badger Meter, lnc. TOW Is a registered trademark of Camcar, Division of Textron, Inc. C Due to card UMS research, Product mp w netZ mW erftn=mft Badger Meter reserves the right to dwwe product or system sp-ificationts witimut notim Please see our website at exDept to the extent an oLdswxftv cord achAd d3rrgatwn exists. 4, www.badgermeter.com s0o; for specific contacts. Badger Meter P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876-3837 / Fax: (888) 371-5982 Copyright 2010, Badger ateW, Im All dgMs reserved. www.badgermeter.com Recordall® Cold Size 1 1/2" (DN 40mm) -technical Water Top Load ANSUNSF Standard Bronze Disc Meter 61 Certified, Annex G Brief DESCRIPTION Badger Meter offers the Recordall Disc meter in Cast Bronze and a Low Lead Alloy. The Low Lead Alloy (Trade Designation: M120 LL) version complies with ANSUNSF Standard 61, Annex G and carries the NSF-61 Mark on the housing. All components of the Low Lead Alloy meter, i.e., disc, chamber, housing, seats, etc., comprise the certified system. APPLICATIONS: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. OPERATION: Water flows through the meter's strainer and into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register.The followermagnet iscennected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register dial face. OPERATING PERFORMANCE: The Badger Recordall Disc meters meet or exceed registration accuracy for the low flow rates (95%), normal operating flow rates (100 t 1.51/6), and maximum continuous operation flow rates as specifically stated by AW WA Standard C700. CONSTRUCTION: Badger Recordall Disc meter construction, which complies with ANSI/AWWA standard C700, consists of three basic components: bronze meter housing, measuring chamber, and permanently sealed register.A corrosion -resistant thermoplastic material is used for the measuring chamber. To simplify maintenance, the register, measuring chamber, and strainer can be replaced without removing the meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of parts among like -sized meters also minimizes spare parts inventory investment. MAGNETIC DRIVE: Direct magnetic drive, through the use of high - strength magnets, provides positive, reliable and dependable register coupling for straight -reading, remote or automatic meter reading options. SEALED REGISTER: The standard register consists of a straight -reading odometer -type tota6zation display, 360° test circle with center sweep hand and flow finder to detect leaks. Register gearing consists of self- lubricating thermoplastic gears to minimize friction and provides long life. Permanently sealed; dirt, moisture, tampering and lens fogging problems are eliminated. Mufti position register simplifies meter installation and reading. Generator -type remote reading and automatic meter reading systems are available for all Recordall Disc meters. All reading options are removable from the meter without disrupting water service. TAMPER -PROOF FEATURES: Customer removal of the register to obtain free water can be prevented when the optional tamper detection seal wire screw or TORX® tamper resistant seal screw is added to the meter. Both can be installed at the meter site or at the factory. MAINTENANCE: Badger Recordall Disc meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. As an alternative to repair by the utility, Badger offers various maintenance and meter component exchange programs to fit the needs of the utility. CONNECTIONS: Tailpieces/Flanges for installations of meters on various pipe types and sizes, including misaligned pipes, are available as an option. Badger Meter .% Model 120 shown with optional 1 ° Test Plug SPECIFICATIONS Typical Operating 21/2-120 GPM (.57 to 27 m'/hr) Range (100%:1.5%) Low Flow 1 114 GPM (.28 m3/hr) (Min. 95%) Maximum 80 GPM (18 m3/hr) Continuous Operation Pressure Loss 4.8 PSI at 80 GPM at Maximum (.33 bar at 18 m'/hr) Continuous Operation Maximum Operating 80OF (26°C) Temperature Maximum Operating 150 PSI (10 bar) Pressure Measuring Element Nutating disc, positive displacement RegisterType Straight reading, permanently -sealed magnetic drive standard. Remote reading or Automatic Meter Reading units optional. Registration 100 Gallons,10 Cubic Feet,1 e, 0.1 m9 Register Capacity 100,000,000 Gallons, 10,000,000 Cubic Feet,1,000,000 m', 100,000 0. 6 odometer wheels. Meter Connections 1 1 /2' AW WA two bolt elliptical flange, drilled or 1 1/2' -11 1/2 NPT internal pipe threads. Test Plugs 1 ° NPT test plug (TP) available on elliptical long and short versions. MATERIALS Meter Housing Cast Bronze, Low Lead AAoy HousingTop Plates Bronze, Low Lead Alloy Measuring Chamber Disc Trim Strainer Disc Spindle Magnet Magnet Spindle Register Lid and Shroud Generator Housing Thermoplastic Thermoplastic Stainless Steel, Bronze Thermoplastic Stainless Steel Ceramic Stainless Steel Thermoplastic, Bronze Thermoplastic RD-T 1 1/2 1a10 PRESSURE LOSS CHART Kato of Flow, in Gallom per M xoo 1 to lea loop ACCURACY CHART Rafe or Flow. in Gallons per Mint _ la _ _ _ joo — — — Iwo A B C D APPROX. METER METER LAYING HEIGHT HEIGHT CENTERLINE SHIPPING SIZE MODEL LENGTH REGJRTR GEN. TO BASE WIDTH WEIGHT it/, 120 EL, Hex 125/8 7° 83/e 25/e 83/" 19 lb. (40mm) 120 EL, TP (321mm) (178mm) (213mm) (60mm) (222mm) (8.6kg) * 120 ELL 13° 7° 8s/e 25/B W/; 19 lb. (Z1l/ rn) 120 ELL, TP I (330mm) I (178mm) (213mm) (60mm) (222mm) (8.6kg) EL = Elliptical ELL = Elliptical Long Sweeo Hand Registration MODEL GALLON CU. CU. METER M120 100 10 1/A :I'D ® zo STE,L„ o O - .70 Geffom 30-:1 40 120 ox R000fte san ms ® 0 0 -7 Cubic Feet 3z AM z RTRe and RecordaIP are registered trademarks of Badger Meter, Inc. TORXO is a registered trademark of Camcar. Division of Textron, Inc. Please see our website at 5' www.badgermeter.com S170> for specific contacts. Copyright 2010, Badger Motor, Inc. AD fW is reserved. Hex = Hexagon, 1 %* -11 % NPT Thread TP=Test Plug 1 ° all! i iQ.Is�.� r�Iitiiitl•■ Ul Due to continuous researaf4 product its and enhamernefft Badger Meter reserves the right to change product or system Vecd*KM= wMW notice, excW to tte extent an outstanding contrachai obligation exists. Badger Meter P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876-3837 / Fax- (888) 371-5982 o www.badgermeter.com Recordall® Cold Size2" (DN 50mm) Technical Water Top Load ANSUNSF Standard Bronze DISC Meter 61 Certified, Annex G Brief DESCRIPTION Badger Meter offers the Recordall Disc meter in Cast Bronze and a Low Lead Alloy. The Low Lead Alloy (Trade Designation: M170 LL) version complies with ANSI/NSF Standard 61, Annex G and carries the NSF-61 Mark on the housing. All components of the Low Lead Alloy meter, i.e., disc, chamber, housing, seals, etc., comprise the certified system. APPLICATIONS: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. OPERATION: Water flows through the meter's strainer and into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanenty-sealed register.The follower magnet is connected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register dial face. OPERATING PERFORMANCE:The BadgerRecordall Discmeters meet or exceed registration accuracy for the low flow rates (95%), normal operating flow rates (100 * 1.5%), and maximum continuous operation flow rates as specifically stated by AWWA Standard C700. CONSTRUCTION: Badger Recordall Disc meter construction, which complies with ANSUAWWA standard C700, consists of three basic components: bronze meter housing, measuring chamber, and permanently, sealed register. Acorrosion-resistant thermoplastic material is used for the measuring chamber. To simplify maintenance, the register, measuring chamber, and strainer can be replaced without removing the meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of parts among like -sized meters also minimizes spare parts inventory investment. The built-in strainer has an effective straining area of twice the inlet size. MAGNETIC DRIVE: Direct magnetic drive, through the use of high - strength magnets, provides positive, reliable and dependable register coupling for straight -reading, remote or automatic meter reading options. SEALED REGISTER: The standard regiisterconsists of a straight -reading, odometer -type totalization display, 3600 test circle with center sweep hand and flow finder to detect leaks. Register gearing consists of self- lubricating thermoplastic gears to minimize friction and provides long rite. Permanently sealed; dirt, moisture, tampering and lens fogging problems are eliminated. Multi -position register simplifies meter installation and reading. Generator -type remote reading and automatic meter rearing systems are available for all Recordall Disc meters. All reading options are removable from the meter without disrupting water service. TAMPER -PROOF FEATURES: Customer removal of the registerto obtain free water can be prevented when the optional tamper detection seal wire screw/or Tons® tamper seal resistant screw is added to the ureter. Both can be installed at the meter site or at the factory. MAINTENANCE: Badger Recordall Disc meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. As an alternative to repair by the utility, Badger offers various maintenance and meter component exchange programs to fit the needs of the utility. CONNECTIONS: Tailpieces/Flanges for installations of meters on various pipe types and sizes, including misaligned pipes, are available as an option. Badger Meter .% Model 170 shown with optional 1" Test Plug SPECIFICATIONS Typical Operating 21/2 -170 GPM (.57 to 39 m3/hr) Range (100% * 1.5%) Low flow 1 1/2 GPM (.34 nftr) (Min. 95%) Maximum 100 GPM (23 rmVhr) Continuous Operation Pressure Iris 3.3 PSI at 100 GPM at Maximum (.23 bar at 23 Wlhr) Continuous Operation Maximum Operating 80°F (26°C) Temperature Maximum Operating 150 PSI (10 bar) Pressure Measuring Element Nutating disc, positive displacement RegisterType Straight reading, permanently sealed magnetic drive standard. Remote reading or Automatic Meter Reading units optional. Registration 100 Gallons,10 Cubic Feet,1 e Register Capacity 100,000,000 Gallons, 10,000,000 Cubic Feet 1.000,000 m3. 6 odometer wheels. Meter Connections 2' AW WA two bolt elliptical flange, drilled, or 2" -11 1/2 NPT internal pipe threads. Optional Test Plug 1' NPT test plug (TP) available on elliptical long and short versions. MATERIALS Meter Housing Cast Bronze, Low Lead Alloy Housing Top Mates Bronze, Low Lead Alloy Measuring Chamber Disc Trim Strainer Disc Spindle Magnet Magnet Spindle Register Lid and Box Generator Housing Thermoplastic Thermoplastic Stainless Steal/Bronze Thermoplastic Stainless Steel Ceramic Stainless Steel Thermoplastic or Bronze Thermoplastic RD-T 2 10-10 PRESSURE LOSS CHART Ram of FbK in GaDws per fAmae 1 10 1e0 raoo ! • • • b O b b ]00 Oi ••• b• ACCURACY CHART Ram o1 Flan in Gallons per Mb vft ra - - - -to - - - -10e — — — rmo A B C D APPROX. METER METER LAYING HEIGHT HEIGHT CENTERLINE SHIPPING SIZE MODEL LENGTH REGJRTR GEN. BASE WIDTH WEIGHT 2' 170 EL, Hex. 151/,' 8' 93/e" 21/8 9'/2 30 lb. (50mm) 170 EL, TP (387mm) (203mm) (238mm) (73mm) (241 mm) (13.6kg) 2' 170 ELL, 17' 8' 93/e" 2r/a 9'/2 30 lh (50mm) 170 ELL, TP (432mm) (203mm) (238mm) (73mm) (241mm) (13.6kg) EL = Elliptical 1fo pwardar, 7 Came Feet oo' (o`o';�p ELL = Elliptical Long Sweep Hand Registration MODEL I GALLON CU.FT. CU. METER W7_07 100 10 1 �,- ';040�o�;oro��] RTR' and RecordalP are registered trademarks of Badger Meter, Inc- TORX' is a registered trademark of Cantrar. Division of Textron, Inc. Please see our website at OSUD,L`"__�' wwnw.badgermeter.com for specific contacts. Copyright 2010, Badger Meter, Irn. AD rights reserved. Hex = Hexagon, 2' -11 V, NPT Thread TP=Test Plug 1' Due to cantiramus ieseamh, product improvements and erttoncerrtertts, Badger Meter reserves the right to change ptadurt or system speaTcatirms wiltrout rwtice, except to the exterd an outstartft cons aclUal d3ligalion e)ists. Badger Meter P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876.3837 / Fax: (888) 371-5982 o www.badgermeter.com Cold Water Technical Recordall® Size 1 1/2° (DN 40 MM) Turbo 160 Meter Brief DESCRIPTION Badger Meter offers the 1-1/2' Turbo Series meter in Cast Bronze and a Low Lead Alloy. The Low Lead AOoy reds Designation: Turbo Series LL- NS) varsian orunplies with ANSi/NSF tandard 61, Annex G and carries the NSF-61 Mark on the product. APPLICATIONS: For use in measurement of potablacold water in commercial and industrial services where flaw is in one direction only. OPERATION: Water flows into the meters measuring element contacting the multi -vaned rotor. Flow readings are obtained by rotor revolutions hansmit- led by magnetic drive coupling through the meter's cover plate to the sealed register. Magnetic drive is achieved by a right angle worm drive, coupling the rotor to a vertical transmission spindle, driving a gear set rotating the magnet carrier. A ceramic magnet in a career rotates around a vertical axis. Through the magnetic coupling, rotor rotation is transmitted to a follower magnet which transmits rotation to the register gearing. The turbo measuring element is designed to greatly reduce wear by reducing friction potential between the moving parts of the rotor and bearing system. Less wear, in this critical area of the design, provides the utility manager with a lower life cycle cost for meter application. Throughout the normal operat- ing range of the meter, the rotor floats between the thrust bearing system. OPERATING PERFORMANCE: The BadgeiORecordallTurbo 160 is designed to provide excellent registration accuracy for the low flow rate, normal operat- ing flow rate, and maximum continuous operation flow. CONSTRUCTION: The Badger Recordall Turbo 160 meter construction which compiles with ANSI and AWWA C701 standards, consists of three basic components: meter housing, interchangeable measuring element and permanently sealed register. The housing is bronze, with elliptical flanges. The measuring element consists of the transmission coupling, measuring element insert, rotor, inlet and outlet straightening vanes with nose cones, and calibration ring assembly.The unique inlet and outlet straightening vanes minimize swirl from piping arrangements upstream as well as downstream. To simplify maintenance, the register and measuring element can be removed without removing the meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of certain parts between 1 1 /2' - 4' like -sized meters also minimizes spare parts inventory investment. MAGNETIC DRIVE: Direct magnetic drive, through the use of high -strength magnets, provides positive, reliable and dependable register coupling for straight -reading, remote or automatic meter reading options. SEALED REGISTER: The standard register consists of a straight -reading odometer -type totalization display, 360" test circle with center sweep hand and flow finder to detect leaks. Register gearing consists of self-lubricating thermoplastic gears to minimize friction and provide long life. Permanently sealed; din, moisture, tampering and lens fogging problems are eliminated. Multi-posdion register simplifies meter installation and reading. Automatic meter reading and dose proximdy systems are available forall RecordaRTurbo meters. (See back of sheet for additional information.) Ad reading options are removable from the meter without disrupting water service. TAMPER -RESISTANT FEATURES: Customer removal of the register to obtain free water can be prevented if the tamper detection seal wire screw or TOW tamper resistant seal strew is added to the meter. Either can be installed at the meter site or at the factory. A tamper resistant calibration plug seal provides protection from unauthorized personnel. MAINTENANCE: Badger Recordall Turbo meters are designed and manu- factured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter instal- lation or at any other convenient location. As an alternative to repair by the utility, Badger offers various maintenance and meter component exchange programs to fit the needs of the utility. CONNECTIONS: Companion flanges forinstallation of meterson variouspipe types and sizes are available in cast iron or bronze as an option. TEST PLUG: An optional 1' NPT test plug puts an end to removing and reinstalling meters during field accuracy and pressure testing. qs BadgerMeter, Inc. 0 av 'SbtM.fn! l i �'F r Grp Turbo 160 with i"Test Plug SPECIFICATIONS Typical Operating 4 - 200 GPM (0.9 to 45.4 m3/h) Range (100%:1.5%) Maximum 160 GPM (36 e1h) Continuous Operation Maximum 200 GPM (45.4m3/h) Intermittent Flow Typical Low Flow 2.5 GPM (0.6 m3/h) (Min. 95%) Pressure Loss 3.8 PSI (.26 bar at 36 m3/h) at Maximum Continuous Operation Maximum Operating 120"F (49"C) Temperature Maximum Operating 150 PSI (10 bar) Pressure Meter Flanges 1 1/2' Elliptical AWWA 125 pound class Register Straight reading, permanently sealed magnetic drive standard. Automatic Meter Reading and Close Proximity units optional. Registration 100,000.000 Gallons 100 gallorWsweep hand revolution. 10,000,000 Cubic Feet 10 cubic ftJsweep hand revolution. 1,000,000 m3 1 m'/sweep hand revolution. 100,000,000 Imperial Gallons 100 Imperial Gallons/sweep hand revolution. MATERIALS Housing Cast Bronze (681), Low Lead Alloy Turbo Head Cam Bronze @81), Low Lead Alloy Nose Cone and Thermoplastic Straightening Vanes Rotor Thermoplastic Rotor Radial Bearings Lubricated Thermoplastic RotorThrust Bearings Sapphire Jewels Rotor Bearing Pivots Passivated 316 Stainless Steel Calibration Mechanism Stainless Steel and Thermoplastic Magnet Ceramic Register Ud and Shroud Thermoplastic, Bronze Trim Stainless Steel RTS-T 1 1/2 91e PRESSURE LOSS CHART Ram of Flow. In Galom per Wilts ACCURACY CHART Ram of Flow, in Galons per Nftft to 100 taco Meter & DIMENSIONS Pipe Size Length Width Height Flange Bolt Circle Centerline No. Net Shipping A B C D E F Bolts Weight Weight 1 1 /2' EL 13' 5 7/32' 6 9/32' 51164' 4' 1 27/32' 14.3 lb. 16.8 lb 2 (DN 40) (330mm) (133mm) (159mm) (20mm) (102mm) (47mm) (6.5 kg) (7.6 kg) ...... , 1 a NPT •�go P-14.I0 •' T•18D ° - D 0 op/,'30- so 40' ,,,,,,... so �.\� f—"*o.� nolr T•teD % A O °• aT .°* E F 's 0 O Q [I 1 3' o a o 55 4 0.6 0.4 PROPER INSTALLATION: The following installation guidelines will insureoptimum field performance and reliability when installing a Badger Turbo meter. 1. A strainer is recommended to insure optimum flow conditioning and protection for the turbo meter measuring element. 2. When using a strainer, five (5) diameters of straight pipe separating the strainer upstream of the meter is recommended. 3. ONLY full -open gate valves should be used immediately upstream of the meter. Butterfly valves MUST be five (5) pipe diameters or more upstream of the meter. Full -open gate or butterfly valves can be used downstream. 4. DO NOT install pressure reducing devices or check valves upstream of the meter. Badger° and RecordalP are registered trademarks of Badger Meter, Inc. Please see our website at www.badgermetercom tiGrorr for specific contacts. CopyVd 2010, Badger Meter. br- Al rights reserved. 5. Unweighted check valves MUST be located at least three (3) pipe diameters downstream of the meter. 6. Pressure reducing devices and externally weighted check valves MUST be located at least five (5) pipe diameters downstream of the meter. BY4VISS Ojlad NT011It TEerP'ORAK M:Haalet Ol,rwE tmcwla tme t V rAko,1EUS a' tar TEST TEE SI RAKi/l Fdti (f luitBU UPSTREAM —1 DOWNSTREAM BADGER PIATE. COUPUNG SERVICE SHUTAFF STRAotER AND TURBO SERIES METERS ADAPTOR SADDLE VALVE Due to oaufirtuotts Pesewch. product mgxoventents and erltmrtcemerft Badger Meter reserves the rot to due W product Or system SpedicatiOns wiihOut naboa. except to the extant an outstanding contractual obligation exists. BadgerMeter, Inc. P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876-3837 / Fax: (888) 371-5982 m www.badgermeter.com FIRM NAME: 6460na/ 1 eekr 4AJ q"�Dmabotl CITY OF FORT COLLINS BID PROPOSAL Water Meters BID NO. 7196 BID DATE: 2:00 p.m. (Our clock) January 14, 2011. WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR Water Meters, PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS. QUANTITY: DESCRIPTION: 3000 ea METER %", SHORT LAYING LENGTH (7 %' LONG) BRONZE MAIN CASE, 8 DIGIT SERIAL NUMBER STAMPED IN CASE. PLASTIC DISC CHAMBER, ABSOLUTE ENCODER REGISTER WITH WALL MOUNT TOUCH PAD, REGISTER COVER, 8 TO 10 DIGIT PRE- PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6 NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, CAST IRON BOTTOM CAP, SCREW MOUNT TERMINALS ON REGISTERS, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METERS SHALL BARE THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER MANUFACTURERS: NEPTUNE T-10, BADGER MODEL 35 (NO SUBSTITUTES), METERS MUST BE FULLY ASSEMBLED WITH REGISTERS INSTALLED ON METER BODY. MINIMUM REGISTER RESOLUTION OF ONE -TENTH (0.1) GALLON VISUALLY AND TEN (10) GALLONS ELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES: BADGER ADE OR NEPTUNE E-CODER (NO SUBSTITUTES) BADGER, MODEL 35; NEPTUNE, T-10; $ 817. S3 Ea. $ o2 41 / Jr 90. 00 Total Mfr. 13a.6e, r Mfr. # Mode � �S Delivery in Weeks: fo S cJ ee Ks 3000 ea METER 3/", SHORT LAYING LENGTH (7 %" LONG) BRONZE MAIN CASE, 8 DIGIT SERIAL NUMBER STAMPED IN CASE. PLASTIC CHAMBER, POTTED ABSOLUTE ENCODER REGISTER WITH REGISTER COVER AND PIT LID MOUNT TOUCH PAD WITH 6 FEET OF WIRE BETWEEN REGISTER AND TOUCH PAD, 8 TO 10 DIGIT PRE-PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6 NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, CAST IRON BOTTOM CAP, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METERS SHALL BARE THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER. MANUFACTURERS: NEPTUNE T-10, BADGER MODEL 35 (NO SUBSTITUTES), METERS MUST BE FULLY ASSEMBLED WITH /I Cold Water Size 2" (ON 50 mm) Technical Recordall Turbo 200 Meter Brief DESCRIPTION Badger Meter offers the 2" Turbo a Low Lead Alloy. The Low Lead Alloy (Trade Deied esig ation: Turbo Series version complies with ANSI/NSF Standard 61, Annex G and carries the NSF-61 Mark on the product. APPLICATIONS: For use in measurement of potable cold water in commercial and industrial services where flow is in one direction only. OPERATION: Water flows into the meter's measuring element contacting the multi -vaned rotor. Flow readings are obtained by rotor revolutions transmit- ted by magnetic drive coupling through the meters cover plate to the sealed register. Magnetic drive is achieved by a right angle worm drive, coupling the rotor to a vertical transmission spindle, driving a gear set rotating the magnet carrier. A ceramic magnet in a carrier rotates around a vertical axis. Through the magnetic coupling, rotor rotation is transmitted to a follower magnet which transmits rotation to the register gearing. The turbo measuring element is designed to greatly reduce wear by reducing friction potential between the moving parts of the rotor and bearing system. Less wear, in this critical area of the design, provides the utility manager with a lower life cycle cost for meter application. Throughout the normal operating range of the meter, the rotor floats between the thrust bearing system. OPERATING PERFORMANCE:The Badgerm Recordall Turbo 200 meter meets and exceeds registration accuracy for the low lbw rate, normal operating flow rate, and maximum continuous operation flow rate as specifically stated in AWWA Standard C701. CONSTRUCTION: The Badger Recordall 2W Turbo meter construction which complies with ANSI and AW WA C701 standards, consists of three basic com- ponents: meter housing, interchangeable measuring element and permanently sealed register. The housing is bronze, with round or elliptical flanges. The measuring element consists of the transmission coupling, measuring element insert, rotor, inlet and outlet straightening varies with nose cones, and calibration ring assembly. The unique inlet and outlet straightening vanes minimize swirl from piping arrangements upstream as well as downstream. To simplify maintenance, the register and measuring element can be removed without removing the meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of certain pans between 1 1/2' - 4' like -sized meters also minimizes spare parts inventory investment. MAGNETIC DRIVE: Direct magnetic drive, through the use of high -strength magnets, provides positive, retiableand dependable registercouplingforstraight- reading, remote or automatic meter reading options. SEALED REGISTER: The standard register consists of a straight -reading odometer4ype totalization display, 360° test circle with center sweep hand and flow finder to detect leaks. Register gearing consists of self-lubricating thermo- plastic gears to minimize friction and provide long life. Permanently sealed; dirt, moisture, tampering and lens fogging problems are eliminated. Mutd-position register simplifies meter installation and reading. Automatic meter reading and close proximity systems are available for all Recordali Turbo meters. (See back of sheet for additional information.) AD reading options are removable from the meter without disrupting water service. TAMPER -RESISTANT FEATURES: Customer removal of the register to obtain free water can be prevented if the tamper detection seal wire screw or TORT tamper resistant seal screw is added to the meter. Either can be installed at the meter site or at the factory. A tamper resistant calibration plug seal provides protection from unauthorized personnel. STRAINER: A separate strainer is recommended to protect the measuring ele- ment. See Technical Brief PS-T-1 for strainer dimensions. MAINTENANCE: Badger RecordatiTurbo meters are designed and manufactured to provide tong -term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. As an alternative to repair by the utility, Badger of- fers various maintenance and meter component exchange programs to fit the needs of the utility. CONNECTIONS: Companion flanges for installation of meters on various pipe types and sizes are available in cast iron or bronze as an lotion. TEST PLUG: An optional 1 1/2' NPT test plug puts an and to removing and reinstalling meters during field accuracy and pressure testing. 01 01 Turbo 200 with 1 1/2" Test Plug I . SPECIFICATIONS Typical Operating 4 - 310 GPM (0.9 to 70.4 m3/h) Range (100% =1.5%) Maximum Continuous Operation Maximum Intermittent Flow Typical Low Flow (Min. 95%) Pressure Loss at Maximum Continuous Operation Maximum Operating Temperature 200 GPM (45.4 m3/h) 310 GPM (70.4 m'/h) 2.5 GPM (0.6 m3/h) 3.1 PSI (.21 bar at 45.4 m3/h) 120"F (49°C) Maximum Operating 150 PSI (10 bar) Pressure Meter Flanges 2' Elliptical or Round Flanges, AWWA 125 pound Gass Register Straight reading, permanently sealed magnetic drive standard. Automatic Meter Reading and Close Proximity units optional. Registration 100,000,000 Gallons 100 gallons/sweep hand revolution. 10,000,000 Cubic Feet 10 cubic ftJsweep hand revolution. 1,000,000 m' 1 ms/sweep hand revolution. 100,000,000 Imperial Gallons 100 ImperialGallons/sweep hand revolution. MATERIALS Housing Cast Bronze (681), Low Lead Alloy Turbo Head Cast Bronze (B81), Low Lead Alloy Nose Cone and Thermoplastic Straightening Vanes Rotor Thermoplastic Rotor Radial Bearings Lubricated Thermoplastic Rotor Thrust Bearings Sapphire Jewels Rotor Bearing Pivots Passivated 316 Stainless Steel Calibration Mechanism Stainless Steel and Thermoplastic Magnet Ceramic Register Ud and Shroud Thermoplastic, Bronze Trim Stainless Steel BadgerMeter, Inc. RTS-T-2 s•10 PRESSURE LOSS CHART Ram ot1eRoK m Gk. per Mk ftsI W ,ciao ACCURACY CHART Ram e1 %K to cadb. per Mf xte ,00 ,aoo DIMENSIONS Meter & Pipe Size Length Width Height Flange Bolt Circle Centerflne No. Net Shipping A B C D E F Boits� Weight Weight 2" EL 10' 5 27/32" 6 1/2' 25/32' 41/2' 21/16' 14.9 lb. 16.4 lb. (DN 50) (254mm) (148mm) (165mm) (20mm) (114mm) (52mm) 2 (6.8 kg) (7.4 kg) 2" RD 10' 6" 7 3/32' S/8' 4 3/4' 2 5/8" 17.4 lb. 18.9 lb. (DN 50) (254mm) (152mm) (180mm) (16mm) (121mm) (67mm) 4 (7.9 kg) (8.6 kg) 1 117' NPT r-mo 00 m �so- b,,, o o� Go 40 ...... a1,d,.a so - r mo = r zoo �e _2 : io.e oz AB 10 °B� 'o� E =F A�f 0 OOOar;:' 00+0000 I 8 4 , oe B PROPER INSTALLATION: The following installation guidelines will insure optimum field performance and reliabilitywhen installing a Badger Turbo meter. 1. A strainer is recommended to insure optimum flow conditioning and protection for the turbo meter measuring element. 2. When using a strainer, five (5) diameters of straight pipe separating the strainer upstream of the meter is recommended. 3. ONLY full -open gate valves should be used immediately upstream of the meter. Butterfly valves MUST be five (5) pipe diameters or more upstream of the meter. Full -open gate or butterfly valves can be used downstream. 4. DO NOT install pressure reducing devices or check valves upstream of the meter. BadgerO and RecordalP are registered trademarks of Badger Meter, Inc. Please see our website at www.badgermetercom tt for specific Contacts. r Sri Copyright 2010, Badger Meter. Inc. AO dgtds reserved 5. Unweighted check valves MUST be located at least three (3) pipe diameters downstream of the meter. 6. Pressure reducing devices and mdemally weighted check valves MUST be located at least five (5) pipe diameters downstream of the meter. ew nss U'VAMWFNT OR VALVE MMM MCNIM NAR IWI Lq�p DIAM I MS OF TEST TFE sllrwc/nl ,'s',: i UPSTREAM ,��' --/ DaVHSTREAM BADGER PLATE STRAINER AND TURBO COUPLING SERVIa- SHUT-OFF ADAPTOR SADOLE VAIVF SERIES METERS Due to continuous research, prDducl hVmvemertts and entw-rnatfts, Badger Meter reserves the right to chanlIa product or system WIcifrcxtions wf'ttfout notice, except to the efderd an ouistardufg contrachial oblgation exists. BadgerMeter, Inc. P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876-3837 / Fax: (888) 371-5982 ® www.badgeryneter.com Model ADE Absolute Digital Encoder Technical Brief Description Applications: The Absolute Digital Encoder (ADE®) is designed for use with all Recordall® Disc, Turbo, Compound and Fire Service meters to provide connectivity with ORION® Badger® ERT®, BadgerTouch® and Badger Meter approved AMR technology solutions. Electronic Resolution: Digital output from the ADE includes the option of either four, five or six dial resolution. Refer to tables on the next page for details. Mounting: The ADE in its shroud assembly uses a bayonet mount compatible with all Recordall Disc, Turbo, Compound and Fire Series meters. The bayonet mount allows positioning of the register in any of four orientations for visual reading convenience. The ADE can be removed from the meter without disrupting water service. Magnetic Drive: A direct -drive, high -strength magnetic coupling through the meter body to the wetted magnet provides reliable and dependable register coupling. Local Indication: The ADE register face features a six -digit mechanical odometer wheel stack, a 360' test circle with sweep hand, and a flow finder to indicate leaks. Tamper -Resistant Features: Unauthorized removal of the ADE is inhibited by a tamper resistant Torx® seal screw, provided as a standard accessory with the ADE. An optional tamper detection seal wire screw is also available. Construction: The housing of the ADE is constructed of a strengthened glass lens top and a corrosion -resistant metal bottom. Internal construction materials are thermoplastic for long life and high reliability. The register gearing is self- lubricating thermoplastic to minimize friction and provide long, reliable life. The shroud assembly is thermoplastic. Temperature: The operating range of the ADE is -40° C to 60' C (-40°F to 140°F). The water meter should not be subjected to temperatures below freezing. Sealing: The ADE achieves true water resistance due to the adhesive technology used to seal the glass dome to the corrosion resistant metal bottom. Leak rates less than 10-6 cc/sec, as tested by a helium mass spectrometer, are comparable to a true hermetic seal. Due to this unique sealing process, the ADE exceeds all applicable requirements of AWWA Standard C707 regarding moisture intrusion. Wire Connections: The ADE is available with either a wire lead, fully potted to prevent moisture intrusion at the connections, or with terminal screws. When provided with a wire lead, the ADE may be pre -wired at the factory to select Badger Meter -approved AMR devices, or may be furnished with a variety of lead wire lengths. Lead wire equipped AIDE registers are suitable for installation in all environments, BadgerMeter, Inc. .3 Specifications Transmitter/Register Straight reading, permanently sealed, magnetic drive Unit of Measure U.S. Gallons, Cubic Feet, Cubic Meters, clearly identified on register face Number Wheels Six with 3/16-inch high numerals Test Circle 360' circle with ten major increments with ten divisions each Weight 11Ounces Humidity 0% to 100% condensing when equipped with potted lead wire, 0% to 95% non - condensing with screw -terminal wire connections Temperature -5° F to 120' F (-20° C to 49° C) Signal Output Industry Standard ASCII Format Visual Resolution 1/100th of Test Circle Electronic Resolution Four-, five- or six -dial resolution Signal Type Two -wire asynchronous for Touch Solutions Power Source I External including continuously submerged water meter pits. The terminal screw version ADE features a tamper -resistant cap over the three -wire terminals. ADE registers with terminal screws are for indoor installation in protected environments, such as residential basements. Electrical: The electronic circuitry is designed to provide immunity to electrical surges and transients per IEC801-2, IEC801-4 Severity Level 4. Operation of the ADE is dependent on the wire length limitations of connected AMR equipment. Operating Characteristics: The digital reading obtained by an AMR device is sensed directly from the position of the ADE register's odometer using internal LED light paths to determine the exact position of each number wheel. This technology eliminates electromechanical contacts that could wear out, and provides greater long-term performance. ADE-T-01 1ao 2.56 v Side View Dimensional Drawing 0 ®®MIN u 4.24, 3.90" with wire lead with terminal screws Top View Dimensional Drawing Measurement Resolution: The minimum electronic resolution of the ADE is as noted below (6 Dial Reading). To verify the correct resolution for your application, contact Badger Meter Customer Service. RECORDALL® Disc Series Size 6 Dial Resolution Gallons 6 Dial Resolution Cubic Feet (FN) 6 Dial Resolution Cubic Meters (m3) M25 5/8" 10 1 0.1 M25 3/4" 10 1 0.1 M35 3/4" 10 1 0.1 M40 1'1 10 1 0.1 M55 11. 10 1 0.1 M70 1•• 10 1 0.1 M 120 1 1 /2" 100 10 1 M170 2" 100 10 1 RECORDALL Turbo Series 6 Dial Resolution Gallons 6 Dial Resolution Cubic Feet (Ft3) 6 Dial Resolution Cubic Meters (m3) 1 1/2" 100 10 1 2" 100 10 1 3" 100 10 1 4" 100 10 1 6" 1000 100 10 8" 1000 100 10 10" 1000 100 10 12" 10000 1000 10 16" 10000 1000 10 20" 10000 10000 10 Please see our Web site at Trey www.badgermeter.com 40 for specific contacts. 0 2010 Badger Meter, Inc. All rights reserved. 6 Dial 6 Dial 6 Dial Resolution Resolution Fire Service Resolution Cubic Cubic Meters Gallons Feet (Ft3) Meters (m3) 3" 100 10 1 4" 100 10 1 6" 1000 100 10 8" 1000 100 10 10" 1000 100 10 6 Dial 6 Dial 6 Dial Resolution Resolution RECORDALL Resolution Cubic Cubic Compound Series Gallons Feet Ft3 Meters m3 2" High Side (Turbine) 100 10 1 2" Low Side (PD) 10 1 0.1 3" High Side (Turbine) 100 10 1 3" Low Side (PD) 10 1 0.1 4" High Side (Turbine) 100 10 1 4" Low Side (PD) 10 1 0.1 6" High Side (Turbine) 1000 100 10 6" Low Side (PD) 10 1 0.1 Resolution stated as individual high and low readings. The ADE should only be connected to a Badger Meter, Inc. approved product. Connection to an unapproved product will void the ADE warranty. ADE, Badger, ORION and Recordall are registered trademarks of Badger Meter, Inc. All other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. BadgerMeter, Inc. P.O. Box 245036 Milwaukee, Wl53224-9536 800-876-3837 ® infocentral@badgermeter.com • www.badgermeter.com BadgerTouch TM BadgerTouch TM Technical Automated Meter Remote Module Reading System Brief DESCRIPTION APPLICATIONS: The BadgerTouchTTM Single Remote Module coupled with the Absolute Digital Encoder (ADETTM) is a complete electronically encoded close -proximity automated meter reading system, specifi- cally designed for single point remote meter installations. This system can be used with all Badger Meter Recordall Disc, Turbo Series, and Compound meters available today. COMMUNICATION: Communication is accomplished by using com- patible reading devices programmed to read BadgerTouch or SensusTM protocols, such as the VersaProbeTM or Metre Pro'sTm reading wands, to interrogate the BadgerTouch remote module. The remote module responds with its serial number, water meter reading, and transmits data in approximately 2.5 seconds. In the event a tamper condition exists, the data collector will not receive a reading. PERFORMANCE: The Badger Meter BadgerTouch automated meter reading system offers operating performance in a variety of applica- tions under most climatic conditions. For consistent results, interro- gation equipment should be placed in direct contact with the remote read pad. METER READING VALIDATION: Further validation of the meter reading can be made automatically by the data collector based on comparison of high -low audit fields in the record. If the meter reading is not between these predetermined limits, an error message is displayed on the data collector display. WIRE CONNECTIONS: The BadgerTouch Remote Module can be installed in new or existing installations where remote meter reading is required. The remote module is connected to the recommended wire that runs between the module and the ADE. A set of terminal screws on the remote module makes this connection. The ADE is provided prewired with either a T, 6% 10' 15' or 25' length of wire that is ready for connection in existing installations. Please see figure 1 for more information on connections. To provide best results, a maximum of 75 feet of wire (Belden #9770) between the remote module and the ADE is allowed. Other wire types may also affect performance. If an additional length of wire is used in addition to that provided with the ADE, a set of gel splices must be made. CONSTRUCTION: The Badger Meter BadgerTouch remote module enclosure is constructed of a high impact plastic enclosure designed for most remote locations. All internal electronic components are encapsulated to provide environmental protection. The ADE provides permanent glass/metal packaging in a plastic shroud and lid for long lasting, highly reliable encoded meter reading information collection. LICENSE REQUIREMENTS: This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes made by the user not approved by Badger Meter can void the user's authority to operate the equipment. No license is required by the utility to operate a BadgerTouch meter reading system. E§ BadgerMeter, Inc. SPECIFICATIONS Temperature: Operating -5° F to +120* F (-20° C to +49° C) Storage -5° F to +120' F (-20° C to +49- C) Humidity 0% to 100% Condensing Ultraviolet Remote enclosure is UV protected for outdoor installation Construction The remote module has a high impact weather proof plastic enclosure containing encapsu- lated electronics and reading coil. The AIDE is constructed of a permanently sealed glass and copper design. Hardware Two terminal screws for connecting the AIDE lead wire to the remote module Noncorrosive tamper resistant TORX® seal screw mounted on ADE shroud and remote housing (optional seal screw available) Weight 6 ounces (not including the ADE) BT-T-03 944 BadgerTouchTM Remote Module 0 0 ADETM Register 0 Cable From Register a 5' or 25' FIGURE 1. BADGERTOUCHT"' SINGLE REMOTE CONFIGURATION RecordalP and RTR®are registered trademarks of Badger Meter, Inc. TORX° is a registered trademark of Camcar, Division of Textron, Inc. BadgerTouchTM and ADETM are trademarks of Badger Meter, Inc. Metre Pro- is a trademark of Metre Pro Technologies Inc. SensusT" is a trademark of Sensus Metering Systems -North America Inc. and its subsidiaries and affiliates. Please see our website at TIN www.badgermeter.com for specific contacts. � �tl Copyright®Badger Meter, Inc. 2004. All rights reserved. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding bid obligation exists. BadgerMeter, Inc. P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876-3837 / Fax: (888) 371-5982 ® www.badgermeter.com BadgerTouch TM Technical Automated Meter BadgerTouch TM Reading System Pit Module Brief DESCRIPTION APPLICATIONS: The Badger Meter BadgerTouchTm Single Pit Mod- ule factory prewired to the Absolute Digital Encoder (ADETm), is a complete electronically encoded close -proximity automated meter reading system, specifically designed for single pit meter installations. This system can be used with all Badger Meter Recordall Disc, Turbo Series and Compound meters available today and is designed to fit pit lid configurations up to 2 inches thick. COMMUNICATION: Communication is accomplished by using com- patible reading devices programmed to read BadgerTouch or SensusTA° protocols, such as the VersaProbeTI or Metre Pro' SW reading wands, to interrogate the BadgerTouch pit module. The pit module responds with its serial number, water meter reading, and transmits data in approximately 2.5 seconds. In the event a tamper condition exists, the data collector will not receive a reading. PERFORMANCE: The Badger Meter BadgerTouch automated meter reading system offers superior operating performance in pit applica- tions and is designed for totally submerged environments. The pit module allows readings under many conditions where ice, sand, or dirt may impede direct contact with the read pad. For consistent results, interrogation equipment should be placed in direct contact with the remote read pad. METER READING VALIDATION: Further validation of the meter reading can be made automatically by the data collector based on comparison of high -low audit fields in the record. If the meter reading is not between these predetermined limits, an error message is displayed on the data collector display. WIRE CONNECTIONS: The BadgerTouch Single Pit Module is factory prewired to the AIDE and does not require additional wiring in the field. CONSTRUCTION: The Badger Meter BadgerTouch pit module is constructed from high impact plastic material that is designed for mounting directly through the pit lid. There is a plastic cover that locks the pit module in place. Inside the pit, a plastic locking nut is used to fit the module firmly in place next to the pit lid. All electronic components internal to the enclosure are encapsulated to provide environmental protection. The Absolute Digital Encoder (ADE) provides permanent glass/metal packaging in a plastic shroud and lid for long lasting, highly reliable encoded meter reading information. LICENSE REQUIREMENTS: This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes made by the user not approved by Badger Meter can void the user's authority to operate the equipment. No license is required by the utility to operate a BadgerTouch meter reading system. BadgerMeter, Inc. .3 SPECIFICATIONS Temperature: Operating -5° F to +120° F (-20 ° C to +49° C) Storage -5° F to +120' F (-20 ° C to +49° C) Humidity 0% to 100% Condensing Construction High impact plastic pit lid nut, adjustment nut, and encapsulated read coil within the plastic pit module. The ADE is constructed of a perma- nently sealed glass and copper design. Hardware Noncorrosive tamper resistant TORX® seal screw mounted on ADE shroud (optional seal screw available) Weight 15 ounces (module and ADE) BT-T-04 9-04 1.75" Diameter Hole Badge I Black Housing .25" ADETM Register 0 Uza 5' and 25' Cable Lengths Available FIGURE 1. BADGERTOUCHT" SINGLE PIT PREWIRED CONFIGURATION Recordall® and RTR® are registered trademarks of Badger Meter, Inc. TOW is a registered trademark of Camcar, Division of Textron, Inc. ADETM and BadgerTouchT" are trademarks of Badger Meter, Inc. Metre Pro- is a trademark of Metre Pro Technologies Inc. Sensue" is a trademark of Sensus Metering Systems -North America Inc. and its subsidiaries and affiliates. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding bid obligation exists. Please see our website at T01 w www.badgermeter.com for specific contacts. � ri1 CopyrightOBadger Meter, Inc.2004. All rights reserved. BadgerMeter, Inc. P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876-3837 / Fax: (888) 371-5982 ® www.badgermeter.com Recordall" Physical and Operating Characteristics Selection Disc Series Meters Guide RECORDALL DISC SERIES METERS SIZES OPERATING RANGE 5/8", 5/8" x 314" 118 to 25 GPM 3/4', 3/4" SL, 3/4' x 1" 318 to 35 GPM 1" 1/2 to 55 GPM 1 1/2" ELL, ELS, HEX 1 1/4 to 120 GPM 2" ELL, ELS, HEX 1 1/2 to 170 GPM BadgerMeter, Inc. 0 FEATURES Meets or exceeds AW WA C700 Standard. Proven design with years of field perfonnance_ Extended -measurement capacity while maintaining exceptional accuracy_ Interchangeability of parts within sizes. Permanently sealed registers with tamper -resistant features. Lower pressure loss at all flaw ranges. RDS-10 740 Physical and Operating Characteristics for Recordall Disc Series Meters Meter Length Inches Safe Max. Maximum Pressure Meter Model Meter Size Bore Dia. Oper. �ssShot�m PSI At Rate Thread (inches (Inches) Capacity, Spud Flang. GPM Ends Ends AW W/A C7104)2 112i 112 x'3/4 at8 71/2 15 GPM 15 PSI ®.15 GPM STANDARDS- Plastic 112,112 x 314 5J8 7-1/2 - 25 GPM 7.4 PSI @ 20 GPM RCDL 25 1/2" AVI�A/A G700 02 1/2,W x 314 5M 7-1V2 - 15 GPM 15 PSI 0 15 GPM STANDARDS Bronze 1/2, 1/2 x 3/4 5/8 7-112 -- 20 GPM 7.6 PSI ® 20 GPM Model LP Bronze 112, 1/2 x 314 5f8 7-1/2 --- 25 GPM 6.0 PSI @ 20 GPM RCDL LP AWWA C71fl-02 5M518 x.3/4 5/8 7-1/2 20 GPM 15 PSI ® 20 GPM ' STANDARDS ' Plastic 5/8 7.4 PSI @ 20 GPM RCDL 25 5f8, 5J8 x 3/4 7-1/2 --- 25 GPM 314 5.0 PSI @ 20 GPM SB" ASTANDA0DS 518 518 x 314 55/8 7AM — 20 GPM 15 PSI @ 15 GPM STANDARDS Bronze 7.6 PSI @ 20 GPM Model LP 518, 518 x 3/4 7-1f2 --- 20 GPM 3/4 5.7 PSI @ 20 GPM Bronze 518 6.0 PSI @ 20 GPM RCDL 25 5/8.5J8 x 3J4 7-1/2 - 25 GPM 314 4.9 PSI @ 20 GPM AWWA C700-02 314 W4 9 --- 3D GPM 15 PSI ® 30 GPM STANDARDS 3/4" Bronze 3/4 314 9, 7-1/2 --- 35 GPM 7.3 PSI 0 30 GPM RCDL 35 AWWA C700-02 1 1 10-/4 50 GPM 15 PSI 0, 30 GPM STANDARDS i" RCDL 55 1 1 10-314 - 55 GPM 5.3 PSI @ 50 GPM RCDL 70 1 1 10-3/4 - 70 GPM 6.5 PSI @ 50 GPM -'A�AC7 1-1/2 12 M 13. 100 GPM '15 PSI ® 100 GPM STANDARDS RCDL 120 1-1f2 1-1/2 12-5/8 12-5/8, 13 120 GPM 7.3 PSI @ 100 GPM WWAC700-02 2 2 15-1/4 17 i60 GPM 15 PSI 960 GPM STANQARDS 2" RCDL 170 2 2 15-1/4 15-1/4, 17 170 GPM 8.6 PSI @ 160 GPM J 0 AWWA C700-90 and C710-90 Standards REGISTERS INSTALLED ON METER BODY. MINIMUM REGISTER RESOLUTION OF ONE -TENTH (0.1) GALLON VISUALLY AND TEN (10) GALLONS ELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES: BADGER ADE OR NEPTUNE E- CODER (NO SUBSTITUTES) BADGER, MODEL 35; NEPTUNE, T-10; $ 7JO Y, Ea. $ 2.3s a 10. oc Total Mfr. 13A.dG e r Mfr. # Mi e 1 3J5- Delivery in Weeks: -3 �D S c.Je e e�CS 528 ea METER 1", (10%" LONG) BRONZE MAIN CASE, 8 DIGIT SERIALNUMBER STAMPED IN CASE. PLASTIC DISC CHAMBER, ABSOLUTE ENCODER REGISTER WITH WALL MOUNT TOUCH PAD, REGISTER COVER, 8 TO 10 DIGIT PRE-PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6 NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, CAST IRON BOTTOM CAP, SCREW MOUNT TERMINALS ON REGISTERS, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METERS SHALL BARE THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER MANUFACTURERS: NEPTUNE T-10, BADGER MODEL 70 (NO SUBSTITUTES) METERS MUST BE FULLY ASSEMBLED WITH REGISTERS INSTALLED ON METER BODY. MINIMUM REGISTER RESOLUTION OF ONE -TENTH (0.1) GALLON VISUALLY AND TEN (10) GALLONS ELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES: BADGER ADE OR NEPTUNE E-CODER (NO SUBSTITUTES) BADGER, MODEL 70; NEPTUNE, T-10;// $ Ea. $ [v % Total Mfr. I3md:8r Mfr.# rnede/ 70 --v Delivery in Weeks:_ .3 fa S- c i ee K.S 664 ea METER 1", (10'/" LONG) BRONZE MAIN CASE, 8 DIGIT SERIAL NUMBER STAMPED IN CASE. PLASTIC DISC CHAMBER, POTTED ABSOLUTE ENCODER REGISTER WITH REGISTER COVER AND PIT LID MOUNT TOUCH PAD WITH 6 FEET OF WIRE BETWEEN REGISTER AND TOUCH PAD, 8 TO 10 DIGIT PRE-PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6 NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, CAST IRON BOTTOM CAP, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METERS SHALL BARE THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER MANUFACTURERS: NEPTUNE T-10,.BADGER MODEL 70 (NO SUBSTITUTES), METERS MUST BE FULLY ASSEMBLED WITH REGISTERS INSTALLED ON METER BODY. MINIMUM REGISTER RESOLUTION OF ONE -TENTH (0.1) GALLON VISUALLYAND TEN (10) GALLONS ELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES: BADGER ADE OR NEPTUNE E- CODER (NO SUBSTITUTES) 98.5/101.5% Maximum Nutations Recommended Max Minimum Test Flow Accuracy At Housing Continuous Flow pate GPM & Normal Flow Material Main Accuracy Percent Limits, GPM Case Per 1 Gal. Per Cu. Ft. Potyrrter;°, . 15 GPM 98.5% ® 114 GPM 1/2 - 25 GPM 49.59 370.9 Polymer '94 114GPw I 1&GPM ° ,• . ; ; .E .. - �eae/c v7.5'GPM'' . ° :..,..," ..,..E 1 :_; ... Leah AtW 10 GPM 95% @ 1/4 GPM 1/4 - 20 GPM 57.4 429.3 Low Lead Alloy 15 GPM 98.5% @ 114 GPM 1/2 - 25 GPM 49.59 370.9 Bronzekow Lead Alloy O'GF'M; 95°iQ. i, 114'GP4•-' 1=`20,GPivA 58 ° d35 ` . ` Omar 15 GPM 98.5% @ 114 GPM 1/2 - 25 GPM 49.59 370.9 Polymer 1U.GPM: ° 9596,.E 114 GPM,• . 1.,-`20 GPM 58 435 . e ► Lead Atby 10 GPM 95% @� 114 GPM 1/4 - 20 GPM 57.4 429.3 Low Lead Allay 15 GPM 98.5910 et 114 GPM 1/2 - 25 GPM 49.59 370.9 Bronze/Low Lead Alloy 15 GPM; 95%-@ 1/2 GPM 2 - 30 GPM' 33.3 250 Srohzekow - Lead Attoy 25 GPM 97% 0 318 GPM 3/4 - 35 GPM 31.6 236.8 Bronze./Low Lead Alloy 25 GPM .95% 3f4.GPM : 3 - 50 GPM 15.3 115 , Lead AWy 40 GPM 95% 1/2 GPM 1 - 55 GPM 14.5 108.9 Bronze/Low Lead Alloy 50 GPM 95% @ 314 GPM 1-1/4 - 70 GPM 11.7 87.5 Bronze/Low Lead Alloy ':o •••Y 7W. e<.'M .q. '"ia°W `1Yrt R..'vr k. '6 ,a,.,V'HChid'...:'.1v y.d:. %!N„-ref.I,'u-,F.J WR n.•. r,.sP. ..4 .. br,..,:er :�A,.-,...4f kk .. ..f�..,.. 50:GPM!, ..<. "% ®i 112"GPM. „ 5 1QD GP[�/l 8 7 D 50a "'Lea3d 60 GPM 951% @i 114 GPM 2-112 - 120 5.97 44.63 Btonzeti--ow GPM Lead Alloy 480 GPM , '•95% 0,2 GPM .x 8 -16D GPMA- 4 Le�a Aar 100 GPM 9500 @ 1-112 GPM 2-112 -170 3.64 272 Bronze/Low GPM Lead Alloy necordap' Is a registered crademask of Badger Metr, hrc. Please see our website at if,.mw% www.badgermeter.com qQP for specific contacts. C opffW Badger Meter, Inc 2010. AO ro15 reserved. Due to continuous research, productimprovem ents and enhancernents, Badger Metier reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. BadgerMeter, Inc. PO. Box 245036, Milwaukee, WI 53224-9536 (800) 876-38371 Fax: (888) 371-5932 ® www.badgenneter.com 0 j RecordallO Physical and Operating Selection Turbo Series Meter characteristics Guide RECORDALL TURBO SERIES METERS SIZES OPERATING RANGE (GPM) 1 Y2" EL 4 to 200 2- EL, RD 4 to 310 3" 5 to 550 3" Fire Hydrant Meter 5 to 660 4" 10 to 1250 6" 20 to 2500 8" 30 to 4500 10" 50 to 7000 12" 90 to 8800 16" 150 to 13200 20" 300 to 19800 BadgerMeter inc, .% FEATURES Compatible with TRACE®, ACCESSplus®, and Read-O-Mati& meter reading systems Complies with AWWA C701 Class II Standard Interchangeable measuring elements within certain sizes Extended high -flow, low -flow capability Low pressure loss Broader calibration range for extended service life RTS-S-10 Physical and Operating Characteristics for Recordall Turbo Series Meters (TSM) Meter Dimensions Maximum Physical Characteristics of Companion Flanges Port Holes Bolt Holes Number Bolt Hole Meter Meter Size Laying Width Height Center Circle of Diameter Model (Inches) Length (In.) (Inches) (Inches) To Base Diameter Bolt Holes (Inches) Inches Inches AWWA,. C7O1=88 1'/x 13' 9 17 < 61/2 Oval Flange Oval Flange-- Oval Flange (Class 11) _ Flanged (Max.) (Max.) (Max.) (Max.) 4 2 5/8. :Turbine Std. , 1'IT TSM 1''h' 13 5 7/32 Oval Flange Oval Flange Oval Flange Oval Flange Oval Flange Model160 617/32 1.85 4 2 23/32 Class II AWWA : _ Oval Flange Oval Flange,, Oval Flange. . C7O1-88 2 18 91/2 20 81/2 41/2 '2 3/4 (Classiq Flanged,; (Max.) (Max.),; (Max.) (Max,) Round Flange. Round Flange Round; Flange Turbine Std. 4 3 4 1 4 3 4 -' 2' Oval Flange Oval Flange Oval Flange Oval Flange Oval Flange Oval Flange TSM 2 10 5 27/32 6 23/32 2 1/16 41/2 2 3/4 Model 200 Flanged Round Flange Round Flange Round Flange Round Flange Round Flange Round Flange (Class 11) 6 71964 258 434 4 34 AWWA C7O1-88 : - 3 24 14 28 13 1/2 6 -4 3/4 (Classlq" '' (Max.) (Max.).. (Max.) (Max.)" 3' TSM 3 12 71/2 8 23/32 3 13/32 6 4 3/4 Model 450 Class it AWWA C7O1'-88 4 ., 29 15 1/2 28. 14 71/2 8 3/4., (Class il) (Max.) (Max.) (Max.) (Max.) 4' TSM 4 14 9 9 21/32 4 11/32 71/2 8 3/4 Model 1000 Class II AWWA '36 C7O1=88 6 1/2 '. 21 31 15 1/2-' 9 112- 8` 7/8: , (Class 11) Turbine Std. (Max.) (Max.) (Max.) (Max.) 6' TSM 6 18 11 13 5/16 51/4 91/2 8 7/8 Model 2000 Class II AWWA C7O1-88 8 43 3/4 27 1/2 31 16 11 3/4 8 7/81 (Class II) (Max.) (Max.) (Max.) (Max.) Turbine 8' TSM 8 20 13 1/2 15 3/16 63/8 11 3/4 8 7/8 Model 3500 Class 11 AWWA r. C7O1-88 10 60 29 35 20 1/2 14 1/4 12 1 (Classll) - (Max.) (Max.) (Max.) `(Max.) Trine 10" TSM 10 26 16 17 15/32 7 7/8 14 1/4 12 1 Model 5500 II AWWA ... 12 31 42 21 17 12 ,,. 1. (CassB) (Max.) (Max.)" (Max.) (M x.)`68 Jurbme Std:� 12" TSM 12 19 11/16 19 19 11/16 8 7/8 17 12 1 Model 6200 (Class II) i AWWA (CLASS11 TURBINE'STANDARDS HAVE NOT BEEN DEVEL PED "F R THE .16'.TURBO METERS a 16, TSM 16 19 11/16 22 13/16 26 5/16 11 7/16 21 1/4 16 1 1/8 Model 6600 (Class II) i:AWWA CLASS II TURBINE'STANDARDS HAVE NOT BEEN DEVELOPED FOR THE 20' TURBO METERS ` 20' TSM 20 19 11/16 28 1/8 30 13/16 14 1/16 25 20 1 1/4 Model 10000 (Class II) >Mr= = AWWA C701-88 Standards Physical Characteristics Cham-dchwistim of Companion Flanges M Wn cad Inn) h"m "A' Safe Operating Max. Rate Max. Loss 98.5/101.5% Extra Low (10 Capacity (Maximum) For Cont. Duty Of Head At Max. Oper. Accuracy at Typical Oper. Flow Range (95% Min.) At At Bolt Hole Hub GPM GPM Capacity PSI Ranges Accur.)GPM OV 'g 6 Oval Flange Oval Flange 200 160 3.8 PSI 4-200 2.5 9/16 13/16 at 160 GPM GPM (Bronze) (Bronze) al Flange &-, Flange�&% - �;Round Flange, IUO b 7 PSI ay 4 160 GPM Ca 9i Oval l­Iange 5/8 (Bronze) 7/8 (Bronze) 310 200 3.1 PSI 4-310 2.5 GPM Round Flange Round Flange at 200 GPM GPM 1/2 (Bronze) 1 (Bronze) T �,3/4, e4 �35V­'­ ���240 (Cast Iron)a (Cast Iron) d at 35 5/8 1 3/16 550 450 1.8 PSI at 5-550 4 GPM (Bronze) (Bronze) at 450 GPM GPM , 15/16 T" 15/1 420 J"PSI 115 6 3 (Cast Iron) `.j,' `;t (Cast Iron) Ob GPM Pm -kV�� 4"" , 4, n.t L _0 11/16 1 5/16 1250 1000 7.3 PSI 10-1250 8 GPM (Bronze) (Bronze) at 1000 GPM GPM (Cast Iron} :9/,6, . !, (Cast Iron), 400- r`i� ­ " �'N 920,�,�-' I I: " T P ��:"'�aj)460 GPM 1- 01'4100, ,GP . .. ... .. 13/16 1 9/16 2500 2000 4.8 PSI 20-2500 15 GPM (Bronze) (Bronze) at 2000 GPM GPM 1 18 3/4 NOV' 1600r 7 PSl r5 C as at 2400 GPM ` GPM 17 "1 15/16 1 3/4 4500 3500 2.5 PSI 30-4500 20 GPM (Bronze) (Bronze) at 3500 GPM GPM 500 1,w­ 757 ., q," 1 3/16 1 15/16 7000 5500 1.6 PSI 50-7000 30 GPM at 5500 GPM GPM /4 f 2'3/$ :500V-", 120 5000r f7' at 500W 41 N 1 1/4 23/16 8800 6200 .8 PSI 90-8800 65 GPM a16200GPM GPM 1 7/16 2112 13200 6600 .5 PSI 150-13200 130 GPM at6600GPM GPM 1 11/16 2 7/8 19800 10000 .5 PSI 300-19800 200 GPM at 10000 GPM GPM Please see our wel site at nN www.badgermeter.com for specific contacts. � �tI Copyright@Badger Meter, Inc.2004. All rights reserved. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding bid obligation exists. BadgerMeterjnc. P.O. Box 245036, Milwaukee, WI 53224-9536 (800) 876-3837 / Fax: (888) 371-5982 ® www.badgermeter.com BADGER, MODEL 70; NEPTUNE, T-10; $ I J 4. 3-1 Ea. $ <P3 c? 74. '�� Total Mfr. gedgr Mfr.# Mocle1 70 Delivery in Weeks: .3 f 0 S r,) e e KS 41 ea METER 1 1/2", (13" LONG) BRONZE MAIN CASE, 8 DIGIT SERIAL NUMBER STAMPED IN CASE. PLASTIC DISC CHAMBER, ABSOLUTE ENCODER REGISTER WITH WALL MOUNT TOUCH PAD, REGISTER COVER, 8 TO 10 DIGIT PRE-PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6 NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, OVAL FLANGED ENDS WITHOUT COMPANION FLANGES, SCREW MOUNT TERMINALS ON REGISTERS, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METER'S SHALL BEAR THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER MANUFACTURERS: NEPTUNE T-10, BADGER MODEL 120 (NO SUBSTITUTES), METERS MUST BE FULLY ASSEMBLED. MINIMUM REGISTER RESOLUTION OF ONE (1) GALLON VISUALLY AND ONE - HUNDRED (100) GALLONS ELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES: BADGER ADE OR NEPTUNE E-CODER (NO SUBSTITUTES) BADGER, MODEL 120; NEPTUNE, T-10; $ 7 9 Ea. $ /0 S 7.3 � 9 Total Mfr. ecLdq.ar Mfr. # Delivery in Weeks: 740 S LA)eeKS 292 ea METER 1 1/2", (13" LONG) BRONZE MAIN CASE, 8 DIGIT SERIAL NUMBER STAMPED IN CASE. PLASTIC DISC CHAMBER, POTTED ABSOLUTE ENCODER REGISTER WITH REGISTER COVER AND PIT LID MOUNT TOUCH PAD WITH 25 FEET OF WIRE BETWEEN REGISTER AND TOUCH PAD, 8 TO 10 DIGIT PRE-PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6 NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, OVAL FLANGED ENDS WITHOUT COMPANION FLANGES, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METER'S SHALL BEAR THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER MANUFACTURERS: NEPTUNE T-10, BADGER MODEL 120 (NO SUBSTITUTES), MINIMUM REGISTER RESOLUTION OF ONE (1) GALLON VISUALLY AND ONE -HUNDRED (100) GALLONS ELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES:BADGER ADE OR NEPTUNE E- CODER (NO SUBSTITUTES) BADGER, MODEL 120; NEPTUNE, T-10; Ea. $ -7S �Sa - Total Mfr. gadse r Mfr. # Mode Id 0 Delivery in Weeks: L j ee KS 18 ea METER 2", (17- LONG) BRONZE MAIN CASE, 8 DIGIT SERIAL NUMBER STAMPED IN CASE. PLASTIC DISC CHAMBER, ABSOLUTE ENCODER REGISTER WITH WALL MOUNT TOUCH PAD, REGISTER COVER, 8 TO 10 DIGIT PRE-PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6,NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, OVAL FLANGED ENDS WITHOUT COMPANION FLANGES, SCREW MOUNT TERMINALS ON REGISTERS, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METER'S SHALL BEAR THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER MANUFACTURERS: NEPTUNE T-10, BADGER MODEL 170 (NO SUBSTITUTES), METERS MUST BE FULLY ASSEMBLED. MINIMUM REGISTER RESOLUTION OF ONE (1) GALLON VISUALLY AND ONE - HUNDRED (100) GALLONSELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES: BADGER ADE OR NEPTUNE E-CODER (NO SUBSTITUTES) BADGER, MODEL 170; NEPTUNE, T-10; $ 3 / 0. S 3 Ea. $ S .s do % S� Total Mfr. Badger Mfr.# Model / 70 Delivery in Weeks: f0 ,5' c.)ee,es 114 ea METER 2", (17" LONG) BRONZE MAIN CASE, 8 DIGIT SERIAL NUMBER STAMPED IN CASE. PLASTIC DISC CHAMBER, POTTED ABSOLUTE ENCODER REGISTER WITH REGISTER COVER AND PIT LID MOUNT TOUCH PAD WITH 25 FEET OF WIRE BETWEEN REGISTER AND TOUCH PAD, 8 TO 10 DIGIT PRE-PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6 NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, OVAL FLANGED ENDS WITHOUT COMPANION FLANGES, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METER'S SHALL BEAR THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER MANUFACTURERS: NEPTUNE T-10, BADGER MODEL 170 (NO SUBSTITUTES), MINIMUM REGISTER RESOLUTION OF ONE (1) GALLON VISUALLY AND ONE -HUNDRED (100) GALLONS ELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES: BADGER ADE OR NEPTUNE E- CODER (NO SUBSTITUTES) BADGER, MODEL 170; NEPTUNE, T-10; q $ .3 / /. OS Ea. $ 5 1. -70 Total Mfr. %3adR 2 r Mfr. # Medea / 7 0 w Delivery in Weeks: /v eeKS 42 ea METER 1 1/2", TURBO WITH BRONZE STRAINER (13" LONG) BRONZE MAIN CASE, 8 DIGIT SERIAL NUMBER STAMPED IN CASE. POTTED ABSOLUTE ENCODER REGISTER WITH REGISTER COVER AND PIT LID MOUNT TOUCH PAD WITH 25 FEET OF WIRE BETWEEN REGISTER AND TOUCH PAD, 8 TO 10 DIGIT PRE- PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6 NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, OVAL FLANGED ENDS WITHOUT COMPANION FLANGES, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METER'S SHALL BEAR THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER MANUFACTURERS: NEPTUNE HP TURBINE, BADGER RECORDALL TURBO 160 (NO SUBSTITUTES). MINIMUM REGISTER RESOLUTION OF ONE (1) GALLON VISUALLY AND ONE -HUNDRED (100) GALLONS ELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES: BADGER ADE OR NEPTUNE E-CODER (NO SUBSTITUTES) BADGER, RECORDALL TURBO 160; NEPTUNE, HP TURBINE; q 6� $ T [o � �a Ea. $ � /6 73. Total Mfr. 3aoCg e. r Mfr. # Ar-erola Il T rbo / 60 Delivery in Weeks: 3 S Ujee KS 31 ea METER 2", TURBO WITH BRONZE STRAINER (17° LONG) BRONZE MAIN CASE, 8 DIGIT SERIAL NUMBER STAMPED IN CASE. POTTED ABSOLUTE ENCODER REGISTER WITH REGISTER COVER AND PIT LID MOUNT TOUCH PAD WITH 25 FEET OF WIRE BETWEEN REGISTER AND TOUCH PAD, 8 TO 10 DIGIT PRE-PROGRAMMED UNIQUE ENCODER REGISTER NUMBER, MEASURING IN U.S. GALLONS WITH A MINIMUM OF 6 NUMERAL WHEEL REGISTRATION OR 6 REMOTELY -READ DIGITS, OVAL FLANGED ENDS WITHOUT COMPANION FLANGES, METERS SHALL MEET THE ESTABLISHED ANSI/NSF 61-2001 FOR MECHANICAL DEVICES, SECTION 8. METER'S SHALL BEAR THE NSF 61 CERTIFICATION MARK. REGISTER PINS NOT INSTALLED ON NEPTUNE'S. ACCEPTABLE METER MANUFACTURERS: NEPTUNE HP TURBINE, BADGER RECORDALL TURBO 200 (NO SUBSTITUTES). MINIMUM REGISTER RESOLUTION OF ONE (1) GALLON VISUALLY AND ONE - HUNDRED (100) GALLONS ELECTRONICALLY (REMOTELY) IS REQUIRED. REQUIRED REGISTER TYPES: BADGER ADE OR NEPTUNE E-CODER (NO SUBSTITUTES) BADGER; RECORDALL TURBO 200; NEPTUNE, HIGH PERFORMANCE TURBINE; $ 5167 7 q Ea.$ /S, m? 1/1 Total Mfr. 8a do/I Mfr.# AcvrA TTr�o a00 Delivery in Weeks: 7LD -s weeKS Grand Total — All Items ........................ $ 7 / I� a 7 l0. 7 The meters being bid meet or exceed the specifications. V11" Yes No. If no, please list exceptions, on a separate sheet of paper and attach to your,bid. Delivery may be a consideration of bid award. For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid. Future orders of meters may be authorized, at the option of the City, from this bid for a period of five years after date of award. Satisfactory pricing and delivery is required for future orders based on this bid. Nofe : Pr + c;r19 IS �'�rm -(or one year. For years a 74roug� S, prices quofed may be ,'n CrPaSPcy I n 74 �e %firvd0cer- Pr-%ce lAdey -iCor Ma�-er%a/s -4or- dUrable- rnan" �'aCY-ur/ n'� as �-e10or--,ked �/. �/e a. S. Depc,r� e� ./- o-/' La6or. 7'�e base ; neho,,e sX4// be 7-he 11)e vem. er- a?o/o J &'/ Lo X , o 40 / TA 'S'. G n a nW c°.S , "1 ,p r C & S' w; l/ �e no m ere �'re q uen-� fX Q n eVerl / '? M&A-I- .s 14' nei-essar/ SUPPLEMENTAL INSTRUCTIONS Prices quoted must remain firm for a 30 day period after the opening date. Freight terms: F.O.B. destination freight prepaid. All freight charges must be included in pricing submitted on proposal and not entered as separate pricing. Any discount allowed by Vendor for prompt payment, etc. must be reflected in quoted figure, and not entered as separate pricing. The City reserves the right to accept or reject any and all quotes. Bidder not responding to the services requested in this bid shall be removed from our automated listing for: Not Applicable Any questions or inquiries regarding this bid should be directed to: Opal F. Dick, CPPO, Senior Buyer (970) 221-6778 NAP V, mPzpgi'W'AN� F: A len4 e7er an COMPANY NAME: WJO S. )'::�raser ��a.oz.f M alto 4� - J, M M � L Te • r• i s y Jr. - Sale TYPM OR PRINTED NAME AND TI LE Stippar -/- ' WI artaaC'r 0 /1 30333 i - q / 00 CO3 d 'I?-Iel 7 (AREA CODE) TELEPHONE NUMBER/FAX T4UMBER -• Y', CfnPeYiriia/ ADDRESS: STREET, CITY, STATE, ZIP e 0 M EMAIL: eo 00o// a / DATE Pluchase Order Terms and Conditions 1. COMMERCIAL DETAILS. Tax exemptoms. By .crate the City of Fort Collins is exempt from sate and local taxes. Our Exemption Number is 93-03301. Federal Excise Tax Exemption Cerzifixa-- of Rt;i=y 94-WO587 is regis:eyed with the Collector of Inter�l Revenue, Deaver, Colorado (Ref Colorado Raised Sm-wes 1073. Chapter 39-26, 1! 4 (a). Goods Rejected. GOODS REJECTED due to faihre to meet speci5cations, either when shipped or die to defects of damaga in rmasir, may be retuned to you for credit and are nor to be replaced except upon receipt of wrirten tosttnccons from the City of Fart Collins. Inspection- GOODS are subject to the City of Fen Collins inspection on arrival. Final Acceptance. Receipt of the merchandise, services or egiipmem in response to this order can result in achonzed payment on the pass of the City of Fan Collins. However, it is to be understood that FINAL ACCEPTANCE is d--e:dent upon completion of a➢ applicable requi-ed inspection procedures. Freight Terms. Shipments most be F.03., City of Fes: Collins, 700 Wood SL, For COMMA, CO 80521 access othernise specified on this Order. if permission is given to prepay freiglm and charge separately, the orirnial freight bill must accompany invoice. Additional charges for Packing- will cot be accepted. Shipment Distance. Alm —macru ins hire distributing poins in ratio= parts of the couaxy, shipment is expected from the nearest disobution point to destmaton, and excess freight will be deducted from Invoice when shipmeun are made from greater distance. Permits. Seer shall procure at sellers solo cost all necessary permits, certificates and licenses required by all applicable laws, relyd3ams, ordinmces and rules of he site, mumapa!3ty, territory or political mbdnision where tit_ work is performed, of required by any other duly commmed public auhoray hiring jurisdiction over the work of vendor. Seer fbaher agrees to bold the City of For, Collins harmless from -and against all liabili,v and loss incurred by them by rmon of an asserted or established violation of any such laws, regulations. otdmamces, niles and requirements. Aurrhori=non All parties to this contract ae•ee that the represeastires are, in far., bona Edo and possess fall and complete aubcnty to bind said parch. MUTATION OF TERMS, This Purchase Order express$ !amiss acceptance to the terms and conditom sated herein set forh and any supplementary or additional terms and conditions annexed hereto or incorporated herein by reference. Any additional or different terms and conditions proposed by seller are objected to sad hereby rejected 2. DM ERY. PLV LSE AMISE PURCMASING AGMIT immediately if yam cannot make cozzptare shipment to arise m y-om promised delivery date as noted Time a of the essence. Defivary and perfomince most be effected within the time stated on the purchase order and the docomenn attached hereto. No acts of the Putrchisen including, winhom limitation, acceptance of partial late deliveries, sball operate as a waiver of chit provision. In the event of any delay, the Purchaser shad bare, in addition to other legal and equimble remedies, the option of placing this order elsewhere and holding the Seller table ford —ages. Foweter, the Seller shall not be liable for damages as a reTe,, of delays due to causes nor reasonably finesmWe which are beyond its reaseuable control and without its Laub of neglgamaN snob acts of God acts of civil a military aurtmities, govercremal priorities, firs, sties, Mod, epidemtirs, wan or riots provided that notice of the conditions camine such delay is eiven to the purchase within five (5) days of the time when the Sella first received knowledge thereof In the evert of any such delay, the date of delivery shall be extended for the period equal to the time actually lost by reason of the delay. 3. W:ARR4NTY. The Seller warrants that a➢ goods, articles, materals and work covered by thiseider will conform with applicable drawings, specifications, samples and'or other descriptions given. will be fit for the purposes intended and performed with the higher degree of cue and competence in accordance with accepted standards for work of a simile mrme. The Seller agrees to hold the purchaser harmless from any loss. damage or expense which the Pmcbaser may suffer or incur on acconm of the Sellers breach of warranty, The Seller %bball replace, repair or make good without cost to :he ptscbasu, any defects or fatrlts ansing w itin One (1) year Or within such longer period of time as may be prescribed by law or by the terms of any applicable warranty provided by the Seller after the date of acceptance of the goods famished heeumder (acceptance tmr to be trinmenabh• delayed), resulting from imperfect or defective work done or tmmWs furnished by the Seer. Acceptance or use of goods by the Purchaser shall not Constance a waiver of any claim under this waraary. Except as otherwise provided in this purchase order, the Seen Iabi r.. , hereunder sball extend to a0 damages proximately caused by the breach of any of the toregaag waaanties or guarantees, but such lability shall in no even: inchide loss of pmfs or loss ofine_ NO LMPIUED W'A-F V.T`v OR afERCHANTAHILITY OR OF FITNESS FORPURPOSE SF-AL.L APPLY. a. CHANGES N LEGAL TERMS. The Purchaser may sake changes to legal terms by written change order. 5_ CF.ANGES N COMUSR?CIAL TERMS. The Purchaser may cake any changes to the terms, other than legal terms. intruding additions; to or deletoms iron the gaantties originally ordered in the specifrcatom or drawings, by verbal or written change Order. If any such change affects the amount due or the time of performance hereunder, an eguinble adjmmsem shall be made. 6. iEUSSIIiATIONS. The Purchaser may it any time by urnmen change order. to mince this agreement as to any or all portions Of the goods then not shipped. subject to any equiab!e adjustment between the pastes as to any work or minerals than in progress provided that the Purchaser shall not be liable for any claims for anticipated profits am the uncompleted portion of the goods and'or work, for incidental or comequenrfal damages, and that no mcb adjustment be made in fat w of the Seiler with respect to any goods which are he Seller standard stock. No such tans imuou &ball relieve the Purchaser Or he Seller of any of heir oh?igatiem as to any goods delivered hereunder. 7. CLAWS FOR ADJUSTMENT. Any claim for adjusmtem must be asserted within thirty (30) days from the date the charge or termination is ordered. 8. COMPLLANCE MM LAW - The The Seller wummu that all goods sold hereunder shill have been produced. sold delivered and famished in strict compliance with all applicable laws and reeulatieas ro'which the goods are subject. The Seller 00 execute and deliver such documents as may he required Co effect or evidence compliance. All Ltw•t and rexWatoas required to be incorporated in agseemems of this character are hereby incorporated herein by this reference. The Seer agree in indemnify and bold the purchaser harmless from all costs and damages suffered by the Purchaser as a resuul- of the Sellers failure to comply with such Isw. 9, ASSIOMMENT. Neither parry shall assign r„re%. or convey this order. or any monies due or to become din hereunder wihom tbe prior written consent of the other parry•. 10. Ti1T_. The Seer wrtams fall clear and unrestricted title to the Purchaser for a➢ equipment. materials, and items fh-- ;-,%ed in Performance of this igreemen tee and clear of any mad a➢ Lens. restrictions, reservations, security interest encumbrances and claims of others. 11. XONW M. =R. Failure of the Purchaser to insist upon strict performance of the tests and conditions bereoi_ EnIme or delay to exercise any rights or remedies prodded herein or by law; failure to promptly notify the Seer in the event of a breach, the acceptance of or payment for goods hereunder or approval of the design. shall not retwse she Seller of any of the warrttes or obligations of this ptachase Order and shall sot be deemed a waiver of any right of the purchaser to insist upon sict pe iormasce hereof or any of as rights or remedies as to any such goods, regardless of when sLVped, received or accepted as to any prior or subsequent defast hereunder, nor shill any ptnported oral r..odilicatoa or rescission of his purchase Order by the Purchaser operate as a wan.a of any of the terms hereof. 12. ASSIGNNMNT OF Ala Is"'RUST CLABIS. Seller and the Purchaser recogz-e that in actual economic practice, overcharges reswlang tom ac=m; violatiocs are in fact bo^.e by the Purchaser. Theretofore, fur good cause and as consideratm for executing this purchase order, the Seller hereby assigns to the Purchaser any and all claims it may am have or hereafter acquired tinder federal or sate antiomt laws for such overcharges relating to the particular goods or services purchased or acquired by the Purchaser panmm to this purchase order. 13. PURCHASERS PERFORMANCE OF SELLERS OBLIGATIONS, lithe Purchaser &:acts the Seller to correct noncocfoxming o: defective goods by a des to be agreed upon by the Purchater and the Seller, and the Seller tbeteafte indicates is inab]ity Or unwilEagness to comply, the Purchase: may cause the work to be performed by the most expeditions mesas available to a, and the Seller shall pay a➢ costs associated with such work The Seller shall m!eme the Purchaser and is contractor Of any ter from all Cabilrry and claims of any mane resulting from the performance of such work. This release thall apply even in the event of feu!: of niglinace of the parry released and shall extend to the directors, o5cers and employees of rucb parry, The Se➢ear's con-narmal oblipmots, i cludng war-xuy, shall not be deemed to be reduced in any way, became such wort is performed or caused to be perfd;ueed by the Purchaser. la. PATENTS. Whenever the Seller is required to me any design, device, material or process covered by Lamar, patent, trademark or copyright, the Seller shall indemnify and save harmless the Purchaser Sons any and all claims for mbrinaeemem by reason of the we of such patented design, device, lateral or process n connection wiib the Cc=ratct, and shall indamaify the Purchaser for any cosi expense or damage which it may be obliged to pay by reason of such infringement at any due during the protecation or after the completion of the work. In case said egopment, or any part thereof orthe intended use of the goods, is in such not held to comtince infringement and the use of said equipment or pan is eajomed the Seller shall, in in own expense and at its option. either procure for the Purchaser the right to continue using said equipmem Orr pats, replace the same with substantially equal but unniabri_.gi t; equipment. or modify it so it becomes ueamfragng. IS_ INSOLVENCY. If the Seller tha➢ become insolvent or bankrupt, make an assignment for the benefit of creditor, Appoint a receiver or trustee for any of the Sellers property• at business, this order may fonhwith be canceled by the Purchaser with= liability. l6. GOVERNNG LAW. The definitions of terms used or the interpretation of the agreement and the rights of all parties hereunder shall be com anted under and governed by the laws of the Stare of Colorado, USA. T2 fu➢awm; Addcoaal Condi ors apply only in cases where :be Seller is w perform wont hereunder, including the services of Seller Represectinv(s), on the premises of others. 17. SELLERS RESPONSIBILITY. The Seller shall carry on said work at Seller's own risk until he same is Stilly completed and accepted, and shall, in case of any accident, destruction or injury to the work and!or materials before Senees anal completion and acceptance, conpL==te she work at Sellers own expense and to the satisfaction of the Purchaser. teen materials aid equipment are fur,,;,t,ars by others for installation or erection by the Seller, the Seller she➢ receive. miload store and have satne at the site and become responsible therefor as though such materials aador equipment wee being famished by the Seller sunder Else order. IS. NSuR,ANCE. The Seller sh4 a: his own expense, provide for the paymiat of w-o&m compensatm including occusaeonal disease bene5n. to is employees employed on or in counemo wih the work covered by this purchase order. ailtor to their dependents in accordance wih the laws of the state in which tb• work is to be dote. The Seller shall also carry comprehensive general liability including bur not limited to, contractual and amomobile public liability imamate with bodily injury and death limits of at lea. a300,000 for any one peas*, a500,000 for any one accideal and property damage limit per accident of 5400,000. TI~ Seller shall likewise require his comraccon, if ate•, to provide for such compensation and inr„-,.,fe. Before ivy of she Sellers err his comtracto.. empbye s &hail do any rands upon the premises ofethers, the Seller shz 0rui h tiles Aachase wish a certiEca:e that such compensation and insurance have been provided. Such certiftcaes dil-I specify the dam when such compet-man and insurance have been provrided Such certificates shall specify the date when such compensation and insurance expires. The Seller egrets that such compensation and insurance %ball be maintained anti after ibs entire work is completed and accepted ! 9. PROTECTION AGAINST ACCDENTS AND JE4-SiAGES. The Seller hereby assomes the entire responsibility and liability for any and all damage, loss or injury of any kind or mare whatsoever to persons or property caused by or resubM from the execution of the work provided for in this patchate order or in connection herewith. The Seller will indemnify and hold hnmless the Purchaser and any or all of the Purchasers of'rcen, agents and employees from and agaimi any and all claims, losses, damages, charges or expenses, whether direct or indirect, and wbether to persons or property run which the Purchaser may be pm or subject by reason of any act action, neglect, omission or default oa the par, of do Seller. any of his contractors, or amy of the Sellers Or COmraCtOn OfScen, asems or employees. In case any suit or other proceedings shall be brought against the Purchaser. or its c0cem agents or employees at any time on account Or by reason of any act, action, neglect omission or default of the Sella of any of his cOnranon or any of its or their officer, agents or emplo)ees our afore%aid, the Seller hereby agrees to assome the defense thereof and to defend the same ar the Sellers own expense, to pay any and all costs, charges, attorneys fees and otber expeases, airy- and all judgmemn that may be mcized by or obtained against the PmchuL, or any of its or their officer&, agents Or employees in such suits or other proceedings, and in case judgment a other lien be placed spas or obtai-ed against the property of tux Purchase, or said parries in or as a result of such suits or other proceedings, the Seller w•➢1 at once cause the same to be dissolved and discharged by giving bond or otherwise. The Seer and Us contractun %ball take all safer• precautions, furnish and install all guards necessary far the pstremisin of accidents, comply with all laws and regulations with regard to safety including• but without hminma the Occap tiamil Safety and Health Act of 1970 and all m!es and reguL-rians issued pursuant thereto. Revised 03R0!0