HomeMy WebLinkAboutCORRESPONDENCE - PURCHASE ORDER - 9110348of
,rt%F°�r
January 4, 2011
Dear City of Fort Collins Water Treatment Chemical Vendor,
Financial Services
Purchasing Division
215 North Mason Street
2nd Floor
PO Box 580
Fort Collins, CO 80522
970.221.6775
970.221.6707 - fax
fcgov.com/Purchasing
Congratulations on being awarded City of Fort Collins chemical business for the
coming year. As part of the requirement for being a selected vendor, the City
requests that you forward the following information as soon as possible:
MATERIAL SAFETY DATA SHEET (MSDS), and
NSF CERTIFICATION
Please forward your information via mail to:
City of Fort Collins Water Treatment Facility
4316 W LaPorte Avenue
Fort Collins, CO 80521
Attn: Rita DeCourcey
Or preferably, e-mail your information in pdf (Adobe) format to
rdecourcey@fcgov.com.
Thank you for supporting the mission of the City of Fort Collins Water Treatment
Facility.
Sincerely,
Ed Bonnette, C.P.M., CPPB
Buyer
r
City of Fort Collins Water Treatment Facility
Fort Collins
_ �,;,;Ey Standard Operating Procedure
Services '
Purchasing Liquid Carbon Dioxide
Author: Rita DeCourcey A s (Si n ures an D t;s):
Section: Administration
Subject: FCWTF SOP for Carbon Dioxide Purch ses �2.2g• /a
Revision Date: December 1, 2010 Lisa vV�tko, Pt, Water Prod6c ion Manager
Chuck Gross, Plant Superintendent
PURPOSE
Establish guidelines for purchasing/delivering Liquid Carbon Dioxide.(CO2) for the Fort Collins
Water Treatment Facility (FCWTF).
The mission of the Fort Collins Water Treatment Facility (FCWTF) is to "provide the community
with a continuous ample supply of treated water that is pleasing, wholesome, free from known
health risks, and affordable. The FCWTF purchases products by determining best value for the
City. Best value is calculated by combining the following four components: (1) the chemical has
been tested in the Pilot Plant and/or approved by the Water Treatment Quality Coordinator; (2) the
chemical can meet or exceed all FCWTF standards, the AWWA standards, the NSF standards,
and any other regulatory agency standards; (3) the supplier can meet all the FCWTF requirements;
and (4) the cost is factored in once it has been determined that a supplier can meet items (1), (2),
and (3) above.
HEALTH AND SAFETY ISSUES
For detailed information, please refer to the most current MSDS document
1. CO2 is primarily an oxidizer. Other hazard classes include being classified as a cryogenic.
2. NFPA Hazard Rating includes:
• Health=1
• Flammability=0
• Reactivity=0
• Special=Oxidizer
3. Personal Protective Equipment:
• Gloves for cryogenic atmospheres. Goggles or a full -face shield. Carbon dioxide
portable analyzer. For spill clean up, SCBA's should be worn.
4. Delivery vehicles:
• Trucks leaking any liquids, powders, substances, etc.; will not be allowed on FCWTF
property. All trucks must use chock blocks on tires; these blocks will be supplied by
FCWTF.
5. Delivery Containers:
• In accordance with the most current AWWA Standard for liquid carbon dioxide, the
CO2 bulk shipment containers will be pressure vessels manufactured to American
Page l
K:/Operate/SOP/CarbonDioxide/CarbonDioxidePurchases.doc
City of Fort Collins Water Treatment Facility
Fort Collins Standard Operating Procedure
P g
Services
Purchasing Liquid Carbon Dioxide
Society of Mechanical Engineers (ASME) pressure vessel code and comply with the
U.S. DOT regulations for'hazardous materials.
INFORMATION FOR THE FORT COLLINS WATER TREATMENT FACILITY (FCWTF)
1. CO2 is budgeted in account 502-032201-534260.
2. CO2 is used in the FCWTF Corrosion control program. CO2 and Lime are combined at the pre
treatment and the clearwell stage to add alkalinity and hardness to the water and thereby
provide corrosion control.
3. FCWTF requires CO2 to have a minimum of 99.5 percent purity.
4. FCWTF requires CO2 to be delivered in bulk quantities.
5. FCWTF has storage capacity for 380,000 pounds of carbon dioxide. There are two 160,000
pound liquid storage tanks and one 60,000 pound storage tank.
6. FCWTF requires that CO2 be delivered within 48 hours of an order.
A. FCWTF has used over 5,000 lbs. of CO2 in one day. FCWTF protocol requires the
container to be between 15,000 and 10,000 lbs. before delivery. A container with only 10,000
lbs. limits FCWTF to 2 days of CO2.
7. FCWTF will reject delivery of any bulk shipments which appear to be leaking, forming ice on
the outside of valves, or have any damaged piping, tubing, hoses, or fittings. The Supplier will
pay the freight charges for all rejected shipments.
CO2
1. CO2 must meet the most current American Water Works Association (AWWA).Standard for
liquid carbon dioxide.
A. Commercial carbon dioxide suitable for use will have a carbon dioxide content of at least
99.5 percent, by weight.
B. CO2 shall contain no soluble inorganic or organic substances in quantities capable of
producing deleterious or injurious effects on the health of those consuming the water or
that would otherwise render the water that had been treated properly with CO2 unfit for
public use.
a. Potential impurities include: hydrocarbons, hydrogen sulfide, nitrogen dioxide, ammonia,
radon, and sulfur dioxide.
C. Water content of CO2 shall not exceed 220 ppm (volume per volume (v/v)-32°F) at the time
of delivery.
SUPPLIER
1. Supplier must be able to supply CO2 in bulk quantities.
2. Supplier must be able to supply CO2 within 48 hours of the telephone order.
3. Supplier must provide an analysis of impurities with each shipment. The analysis shall be
submitted prior to delivery. The analysis should include, but is not limited to: acetaldehyde,
benzene, carbon monoxide, carbonyl sulfide, hydrogen sulfide, hydrogen, methane, moisture,
ZNEtJy
Page 2
%/ = K:/Operate/SOP/CarbonDioxide/CarbonDioxidePurchases.doc
Ml
f to FE A
City of Fort Collins Water Treatment Facility
Fort Collins
Standard Operating Procedure
seNceg Purchasing Liquid Carbon Dioxide
other hydrocarbons, oxygen, radon, and sulfur dioxide. This analysis can be faxed ahead of
the delivery or delivered by the driver at the time of delivery.
4. The supplier must ensure that the shipment is delivered in tank trucks in pressure vessels
manufactured to American Society of Mechanical Engineers (ASME) pressure vessel code and
complying with the US DOT regulations for hazardous material transportation.
5. Each year in January, the supplier will mail to FCWTF a new copy of the MSDS sheet and/or
the web site location of the most current version.
6. Each year in January, the supplier will mail to FCWTF a copy of the NSF Certification and
AWWA conformance letter.
7. Supplier will be responsible for the shipping costs of the shipment if the delivery is rejected and
returned because it does not meet the standards expressed in this SOP.
8. Supplier will perform an annual inspection of all three of the carbon dioxide storage tanks for a
cost determined during the bid process or contract renewal.
DELIVERY
1. All chemical suppliers must fax to the FCWTF (970-221-6736) the following information prior
to delivery:
a) the name of the driver making the delivery
b) the numbers of the tractor and trailer transporting the chemical
2. Delivery trucks must park in the designated area on the north side of LaPorte Avenue
outside of the entrance gate. Use a cellular phone to call the facility at (970)221.6690 or
walk to the entrance kiosk and press the red call button. Please do not block the facility
entrance on LaPorte Avenue. All deliveries are checked by FCWTF personnel prior to
entry.
3. The receptionist or person answering the telephone must contact the Duty operator. The Duty
operator will verify the delivery from the schedule board. The operator or designee will meet
the truck at the parking area outside the gate.
4. A list of all Praxair drivers is posted in the FCWTF control room. If the driver is not on the list,
the truck will not be allowed to enter the facility. The Plant Superintendent will be contacted
and the delivery may be rejected.
5. The truck fitting will be sealed with a color coded security tag at the point of origin.
6. The security verification, the supplier's quality assurance analysis, and the City's lab analysis
will be given to the Water Quality Coordinator in order to identify the load in the event of any
problems.
7. The Plant Superintendent or the duty operator must approve all deliveries. The Plant
Superintendent monitors the tank levels and places orders with the supplier, setting the
delivery date and quantity.
8. Delivery drivers will provide a sample and submit it to the Operator at the time of delivery. The
driver will be instructed on how the samples will be taken:
A. The sample draw will be from the main discharge line of the truck.
B. Protective gloves are required when taking and delivering the sample
9. The Operator will take the sample to the on -site Laboratory Technicians for analysis.
10. The delivery driver must wait for the results of the laboratory, test before unloading the truck.
ON
Page 3
K:/Operala/SOP/CarbonDioxide/CarbonDioxidePurchases.doc
` ,a♦
City of Fort Collins Water Treatment Facility
Fort Collins
Standard Operating Procedure
Services purchasing Liquid Carbon Dioxide
11. Delivery drivers are required to provide certified weight tickets for both the empty and loaded
weights of the tractor and trailer unit. All weight tickets should have the tractor and trailer
numbers written on them, as well as the name of the facility, FCWTF,
12. Delivery must be made within 48 hours of the order being placed.
13. Delivery may only be made Monday through Friday from 8 A.M. to 5 P.M.
14. Delivery drivers are responsible for off-loading the CO2.
15. Delivery drivers are required to chock and unchock their trucks.
16. Delivery drivers should meet with the operator to become familiar with the location of phones,
alarms, and emergency showers that are nearest to the off-load location.
17. FCWTF will reject delivery of any bulk shipments that are leaking, forming ice on the outside of
valves or have damaged piping, tubing, hoses, or fittings.
PURCHASING
1. All contracts and purchases will be made in accordance with the City of Fort Collins
Purchasing Department (FCPD) Purchasing Procedures. A copy can be obtained through the
Purchasing Department. The Purchasing Department will ensure adherence to the FCPD
Purchasing Procedures.
2. FCWTF requires that all suppliers submit the names, locations, and phone numbers of three
current clients as part of any bidding process.
3. FCWTF requires that all suppliers submit a list of intended delivery agents (motor carrier) and
a letter from the U.S. Department of Transportation, Federal Highway Administration, stating
the Motor Carrier Safety Rating for the company as part of any bidding process. Each listed
motor carrier's rating must be Satisfactory or above to be considered in the bidding process.
4. FCPD representatives are responsible for ensuring that the items noted in this SOP can be
met by the supplier before any contract is awarded.
5. The FCWTF and FCPD will establish, at the beginning of each New Year, a Blanket Purchase
Order.
6. FCWTF Operations/Process Supervisor or his designee will place delivery orders on that
Purchase Order throughout the year. FCWTF must be able to place orders using telephone,
fax, or electronic mail.
7. When placing an order, a delivery date will be specified.
8. This SOP can act as the sole -source justification if only one supplier can meet the criteria
specified above.
Page 4
P10,