HomeMy WebLinkAboutRESPONSE - RFP - 7173 BUILDING COMMISSIONING ANNUAL FEDERAL (2)Annual Commissioning Services For City cif F&tIC tfift w RFP 7173 — Building Commissioning Annual Federal Offered by: Cube, Inc. Energy • Efficiency • Environment • Technical Consulting Boulder . Chicago October 11, 2010 (P1089) City of Fort Collins Annual Commissioning Services E Cube, Inc. b) Contractor Aids i Eauinment StartuD October 11, 2010 Paae 10 IDENTIFICATION PUMP # LOCATION DATE: TECHNICIAN: NAME / COMPANY / PHONE: NAMEPLATE DATA 1 Pump Manufacturer Motor Manufacturer 2 Pump: model: serial number: 3 Motor model: frame: serial number: 4 Horsepower: RPM: Im leller size: Design m / head 4 Rated - Volts / Ph / FLA / SF / PF / EFF INSTALLATION YES NO NA COMMENTS / CONDITIONS 1 Is there any visible damage 2 Is piping independently supported & straight 3 Are all piping joints leak tight 4 Is the foundation level 5 Is the base bolted down, all bolts and fasteners tight 6 Proper number of shims 7 Is the base grouted in position 8 Are all service connections properly connected 9 Are accessories mounted and operating ro erl 10 Are all guards in place 11 Correct inlet screen in place LUBRICATION 1 Have the motor bearings been greased/oiled (list type of lube) ii Testing Specification #: Date Description: Initials HW and CHW Water OK Comments 1) Piping complete and all hydro test complete and signed off 2) Flush for a period of time long enough to assure removal of ALL dirt and foreign mater from piping system. 3) Bypass all coils, control valves, heat exchangers and any factory cleaned equipment 4) Sectionalize system to flush at sufficient velocity @6 fps (measured), Temporally connect any dead-end supply and return headers Open all control valves and assure they remain open for the duration of the flushing. Flush bottoms of risers Do not flush through chiller, boiler or ice tanks until after distribution system has been thoroughly cleaned. 5) Drain until collected water samples are determined to be visually clear. 6) Cleaning: After initial flush add cleaning solution at the concentration recommende1bythe manufacturer. Circulate cleaning solution for at least 24 hours. 7) Flush out cleaning solution or neutralize until the water is at an acceptable concentr level per the cleaning solution's manufacturer's specs. 8) CHW Piping: Refill the CHW pipe with clean water for the installation of water chemistry as specified. Note that the chemical treatment provider will need to be ready to respond at the time of this filling. 9) CHW Follow -Up: Circulate the CHW system while monitoring/cleaning the fine -mesh screens in the pumps. Remove once the screens no longer are accumulating material but prior to test and balance. © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 • Fax (312) 441-9611 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 City of Fort Collins Annual Commissioning Services October 11, 2010 E Cube, Inc. Page 11 iii Procedural Guidelines GENERAL PUMP & P/T ARRANGEMENTS 3/26/98 PUMP TEE PIPED INTO THREADED FLANGE FLANGE TAP Ak P/T PLUG PUMP TEE PIPED INTO THREADED FLANGE TAP Prr PLUG PUMP FLANGE GAUGE PUMP TEE PIPED INTO FLANGE THREADED FLANGE TAP P/T PLUG DIFF PRES. PUMP DEVICE \/ P/T PLUG PUMP TEE PIPED INTO FLANGE THREADED FLANGETAP PUMP WITH FLANGE TAPS UNUSED PUMP WITH FLANGE TAPS PIPED TO PLANNED GAUGE, TEE W/ GAUGE PIPED ON BRANCH & P/T PIPED ON RUN (4" Max. length from P/T into pipe flow) PUMP WITH FLANGE TAPS PIPED TO PLANNED DEVICE, TEE W/ DEVICE PIPED ON BRANCH & P/T PIPED ON RUN (4" Max. length from P/T into pipe flow) E-Cube, Inc. -3 © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 • Fax (312) 441-9611 City of Fort Collins Annual Commissioning Services October 11, 2010 E Cube, Inc. Page 12 4) LEED Experience Commissioning LEED-NC: 100 LEED-EB 4 LEED-CI 11 LEED-Campus 2 LEED-Retail 1 LEED-CS 3 LEED-HC 2 Total 123 5) Why E Cube • Your day-to-day E Cube contact is just a few blocks away - quick turn -around time • Experienced employees to choose from if subject matter expert is needed - solve issues quickly • National Cx project experience - delivers best practices • Project Manager who understands your needs. - Owner's perspective! • Excellent combined municipal commissioning experience, meaning a lower learning curve = improved schedules • We have systems and tools that drive predictable outcomes — (no surprises) © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.Lcube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 • Fax (312) 441-9611 City of Fort Collins Annual Commissioning Services October 11, 2010 E Cube, Inc. Page 2 5 Cube, Inc.. Energy • Efficiency • Environment • Technical Consulting City of Ft. Collins Building Commissioning Services Annual Federal Proposal No. 7173 1) E Cube Commissioning Process 2) Contractor Buy -in 3) Commissioning Forms a) Project Management Forms b) Equipment Field Commissioning Forms c) Contractor Aids 4) LEED Experience 5) Why E Cube © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 • Fax (312) 441-9611 City of Fort Collins Annual Commissioning Services October 11, 2010 E Cube, Inc. Page 3 1) E Cube Commissioning Process E Cube offers a structured, systematic and well grounded process THE QUALITY BUILDING PROCESS® Design Review (SD, DD, CD Phases) Design Phase Develop Commissioning Plan and Specifications Construction Phase Typical MEP System Typical Control System O&M Manuals Commissioning Process Commissioning Process and Training .Pre Functional•Proce'dures Pre -Functional Checklists O&M Preparation c co st-StartuF Point to Point Testing I I Network Verification I Programming ling I I Sequence Checks and Tuning -� Functional Checkouts Integrated Systems Operation Training Preparation Draft O&M Manuals Final O&M Manuals Owner Training %COMPLETE OPERATING SYSTEM' t" Layered Approach to Hip-h Performance Facility commissioning 2) © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 • Fax (312) 441-9611 City of Fort Collins Annual Commissioning Services E Cube, Inc. 2) Contractor Buy -in i Kick-off meeting Clear roles and responcibilities Becoming part of the team "Project Name" "Location" Commissioning Process Roles and Responsibilities Matrix Role Definitions F C F October 11, 2010 Paae 4 Key (By decreasing level of effor qualifiers P Primary responsibility +/- Indicates level of involvement A Assists * Optional task C Coordinates R Reviews & responds Primary Responsibility Responsible for successful completion of task. Actively Assists Actively assists party with primary responsibility on Coordinates Expedites completion of task by coordinating with Reviews & responds Reviews email, meeting minutes and other documents O U vi PHASE Notes & Comments ) w V U a w v Develop Commissioning A R R A/R+ P Ian Develop Commissioning spec (made available if so A R R A/R+ P desired Commissioning Kick Off R C P A Plan for mtg. w/ Prime contr & key subs Meeting(s) attend prior to contr. coord. Regular scheduled mtgs to review cx Cx Progress Me ' R R- - A A progress, issue status, cx planning & scheduling Pre -Functional Procedure CA finalizes project -specific forms to verify and Form Development * C- P equip/sys installation meets contract req. and is read for startup Pre -Functional Procedure A.L C P A mpletes prefunctional checklists w/ 4 Execution a t c from contractors as needed . Contr./Vendor Testing and I CA revi w contr./vendor testing and startup Start-up Proced./Form R* A- P forms oc u prior to execution Submittal &Review Specified Contr./Vendor Pre A* A/C A- cludes pipe ak testing, megger & hi - Startup Testin stin of elec . s., etc. Specified Contr./Vendor A* A/C A- P I al tion of MEP equip & systems. Equipment Startup Specified Contr./Vendor A* A/C A/C P Include B BAS Pt-Pt/calib./SoO Iirg Ge TS testing, Med Testing checkouts, Gas Cert. etc. Equip/Sys Level Functional CA finalizes project-s rocedures and Peformance Verification R* C- P R forms to verify & document operation & Procedure Development performance of e u ment ands stems. Equip/Sys Level Functional Verifies operational performance of equipment Peformance Verification A* C P A+ & systems, culminates in IST. CA leads Procedure Execution process w/ assistance from contractors/vendors (esp. BAS . © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 • Fax (312) 441-9611 ' City of Fort Collins E Cube, Inc. Annual Commissioning Services ' ii Startup/ Controls/ T&B meeting Speacilaized meeting for specific critical tasks COMMISSIONING PROCESS Pre -Functional Checklists assure all equipment and associated devices are installed and substantially ready Pre -Functional for start-up. ' Checkout This includes but is not limited to: cleaned, wired, greased, oiled, aligned, clearance, rotation checked. Pre -Operational 01 Contractor Testing the contractors personnel, fill out appropriate documentation. This assures that ALL Pre -Operational system components have been tested and is ready for ' Contractor Testing start-up. This includes but is not limited to: hydro., pressure, duct leakage, meggar, torquing, etc. Start-up is performed by the vendor or the contractors designated start-up personnel, who will fill out ' appropriate start-up documentation. This assures that Contractor/ Vendor. ALL equipment has been checked and is ready to be Start-up operated as needed for T&B and Functional checkout. ' This includes but is not limited to: volts & amps on all 3 phases, bearing temperature., etc. Contrator Dynamic testing of operational systems T&B and and controls. Contractor 4 At this point systems are fully balanced, tested, Operational Testing operational and ready for Functional Performance Checkout. Functional Functional Performance checkout of individual ' Performance 4 equipment componants, as well as integrated Checkout systems functionallity. Cube, Inc. (303)443-2610 October 11, 2010 Paae 5 © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 • Fax (312) 441-9611 City of Fort Collins Annual Commissioning Services October 11, 2010 E Cube, Inc. Page 6 3) Commissioning Forms a) Project Management Forms i Status & Tracking Pre -Functional Start -Up Post Startup Testing Functional Equipment/System Sub IN fn %Complete,PF oc r (b) rm red rev St -up oc rc (b) Maini form oc r (b) fn %Complete,FF kcred, NOTES HVAC Ductwork Galv Fans: Centrifugal, Utility, Propeller i nal H ,na ® Iffil ® na M1 na Mna. ` na,,- AHU-1 IN. N ® 0 AHU-2 Rimini HVAC CHWICW HVAC Piping ;na na na iia: '+ na : na; na na' na - na,;, HW HVAC Piping na; .na! ® na ` . Ana b ;,n8 na^ _, na na;,na; Hydronic Specialties n was na na °ria�i.na`° Exp Tank ET-1 na na na Exp Tank ET-2 & 3 ®� na - na na ns= na Piping - Steam distribution „na' na; na ; r na na, , na_ ;g_ na na na a na`, na ` Steam Boiler ME Deaerator e Hot Water Boiler Centrifugal Chillers Cooling Towers 0110101 a U1 Variable Frequency Drives ®. Pumps, Base Mount E 90% 0 WHO M Packaged Pumping Systems IN M Is swum Condenser Water Filtration MEN Condenser Water Chem Treatment SEE 1 101101 © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 9 Fax (312) 441-9611 City of Fort Collins E Cube, Inc. Annual Commissioning Services ii Field Observation Notes Last undated on: 09/17/09 Bv: JD October 11, 2010 Paae 7 Number of Items: 15 Item Date Noted o Respon. Affected Date System/ Affected Area Issue Description Issue Status No. * L Party * Resolved Equip. 40 9/3/2009 H BLL AHU-W 10 AHU Need catwalk to complete commissioning 9/17 no change Network 1 st flr control 43 9/3/2009 H BLL Need trimed out for controls connection (/17) Work in Progress connections I room Vertical clearance for motor replacement is (4/7/09) Verify during start-up Dom booster approx. 4" above two of the motors. (OA duct 12 6/25/2008 I BLL I M with manufactor's rep. pump for AHU-W2 is above) It may not be possible (4/10/09, JW) Facilities to look at remove the motors during replacement. 49 9/17/2009 1 BLL AHU-9 AHU-9 No safe access to service AHU-9 JCI needs access to damper 46 913/2009 1 FEM AHU-6 OA Damper OA damper does not operate ductwork Conduit containing EM circuits not marked 26 3/26/2009 H Huen Conduit identification (4/10/09 JW) in progress "emer enc "sec 16195 2.0213 33 8/25/2009 1 H Huen EF-7 Lab 207 fan not wired cannot test fan/controls 9/17 no change Field Observations Open Contract items items © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 9 (312) 441-9610 • Fax (312) 441-9611 City of Fort Collins Annual Commissioning Services October 11, 2010 E Cube, Inc. Page 8 Equipment Field CommissioningForms iii Prefunctuional Check sheets NMH NEW PRENTICE WOMEN'S1 1 1SPECIFICAT III I► ! ' ►/ ' Sitstem/Eauiument1 1 1 on: Reference 1 u �1 .1� • ►� 1� ► rem 11RIM I I• •1 "1-1 • n u - 1 -1 - • •' 1 • 211 Traslt/debris_ 11 • " • • 11 . 1 • _ 1 r - e •11 •1 • I I- 1 • 1 •. ' I.1 • . 1 1 1 • 1 11 1 • - 1 © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 9 Fax (312) 441-9611 City of Fort Collins Annual Commissioning Services E Cube, Inc. iv Functuional Check sheets October 11, 2010 Paae 9 NMH NEW PRENTICE WOMEN'S HOSPITAL COMMISSIONING SPECIFICATIO APPENDIX 6 - SAMPLE FUNCTIONAL PERFORMANCE CHECKLISTS AIR -HANDLING UNIT S stem/E ui ment ID: Location: ITEM Design I Actual COMMENTS Preheat Coil Per ormance HW control valve position Entering/LeavingEntering/Leaving HW pressure Water -side dP HW Flow rate GPM Entering/LeavingEntering/Leaving air temperature Air -side dT Entering/LeavingEntering/Leaving HW temperature Water -side dT Local thermometers read OK Coofin2 Coil Per ormance CHW control valve position Entering/LeavingEntering/Leaving CHW pressure Water -side dP CHW flow rate GPM Entering air temperature / ° RH Leaving air tem eraure / % RH Air -side dT Air -side dH Entering/LeavingEntering/Leaving HW temperature Water -side dT Local thermometers read OK Humidi cer Performance Steam control valve position Entering steam pressure Entering air temperature / % RH Leaving air tem eraure / ° RH Humidification rate #/hr COMMENTS AND OBSERVATIONS © 2010 E Cube, Inc. 1900 Folsom, Suite 109 • Boulder, CO 80302 • (303) 443-2610 • Fax (303) 443-3704 www.ecube.com 118 South Clinton, Suite 650, Chicago, IL 60661 • (312) 441-9610 • Fax (312) 441-9611