HomeMy WebLinkAboutRESPONSE - BID - 7120 BACKFLOW ASSEMBLY TESTING AND REPAIRBID SCHEDULE
7120 BACKFLOW ASSEMBLY TESTING AND REPAIR
Award will be based on lowest total for all phases (1 through 3) of the Bid Schedule.
2.
3.
4.
Provide testing of any size PVB $ per test X 76 = $ % �$
Provide testing of any size RP $ 3) - a per test X 55 = $
Repair labor rates $ 0 per hour X 6 hrs $
GRAND TOTAL $ %1/4 .5-? W
Maximum material mark-up City will pay:
1) < $500.00 + 10% Bidder's mark-up /0 %
2) > $500.00 + 8% Bidder's mark-up %
Since miscellaneous materials and minimum charge will be a minor factors with this contract in
most cases, they will not be calculated in bid method of award, but contractor must honor both
mark-up rate and minimum charge.
FIRM NAME I cJ d /o cli
Are you a Corpor tion, Partnershi DBA, LC, or PC
1
SIGNATURE
ADDRESS l S Y_ Q s 4 17-2 n d
Lav�I�►-L� �� �'os�`�
PHONE/FAX# 4%a.aO
5
All American BackflowO (970 )
391-0006
��M
Lynnette kein
215 East 2nd St.
CI� Loveland
TfIS7�EST= 2/16/2010
c0 SIP 80537
�P",�
�Ar t Watts �t��E
TK99E
TESTNO 467957217 :111 ;� 2l16/2011
MANOMETER
GAUGE READING
BEFORE AFTER
ADJUSTMENTS ADJUSTMENTS
1 psi
PSI-1: 0.9
1.00 PSID
3 psi
3.00 PSID
5 psi
PSI-5: 4.8
15.00 PSID
7 psi
7.00 PSID
9 psi
pSI-9: 8.8
1 9.00 PSID
11.00 PSID
11, psi
13 psi
13.00 PSID
COMMENTS
TECHNICIAN:
Calibration and adjustments are accurate to 1 percent of gauge range at the time of calibration, . Due
to the nature of gauge and the sensitivity to shock, No warranty is given or implied after the gauge
has left out facilities. Calibrations are done on a manometer reconignzed by NIST as a priamay
standard and traceable to NIST.
!NT
Rathet ZbQ4
Tertif irativlu
BACKFLOW PREVENTION
INSTITUTE
BackfCow 1r''reventionAssem6Cy Tester
Lynnette Seim
has demonstrated compliance with the llir�r000p�i00006�oogea�e
by successfully completing the requirements of
,AS9,61, NSj Standard 5110 - Xackflow preveKtlofl Assefffbly fester
at the City of Xwgmont, Za gwont, eolomdo
on this, the 15th day of March, 2008.
certificatiom JVuxber: 15220
Americam Society of Sanitary Sngineerin9
for plumbing and Sanitary.Remarch
,4SSS baernattonal president, 9oseph 3ugelo
Oriykal eertifieatiotr: 0311812008 1�ecertifiea:• 03/18/2008
,International Association of plumbing
and Al echanical Officials
,I TA-40 president, Koff Rice
Colorado Divisk
Fire Supp Tess
By Issue Of This Registration, The State OfCo lorac
Lynnetta"keim,'."_
Name;
All A, eric6n,'BaCA
Dated this
Expiration Date
of Fire Safety
ProgramReglstrafion No. 1OB982
isiofi'6fFird,Saf6ty Recognizes
Who Is Principal Of
vv
As A
�a ,
pres8mo'n Sy,
Fire SQ,"d" I
in ac dance with Cofdirado,� visects. tes, 24-315-1
This Regisirag"ill remain in effect until expiration subject Wthe
Suppression Administrator'"'"
Contractor
'A, 20 Q9--
n 6f Fire Safety
ion'; dniinistrator
regulations of the Fire
d
S4
I
'I
I
(E