HomeMy WebLinkAboutRESPONSE - BID - 7127 COLLEGE HARMONY INTERSECTION IMPROVEMENTS FEDERAL AID PROJECT NO. STU M455-077r �
ity Financial Services
Cof Purchasing Division
215 N. Mason St. 2"d Floor
PO Box 580
F6rt- uoilin:,03-4 Fort Collins. CO 80522
970.221.6775
970.221.6707
�Puir�Clhasiinq fcgov.com/purchasing
ADDENDUM No. 3
SPECIFICATIONS AND CONTRACT DOCUMENTS
Description of Bid 7127: College/Harmony Intersection Improvements
Federal Aid Project No. STU M455-077
OPENING DATE: 3:00 P.M. (Our Clock) April 21, 2010
To all prospective bidders under the specifications and contract documents described above,
the following changes are hereby made.
CHANGE:
Bid Opening Date Has Been Changed To April 21, 2010.
Revisions to the Project Special Provisions:
A. Revision to Section 420 - Geosynthetics
The project special provision for "Geotextile (Crack Reduction) (High Density)" is deleted
from the Project Special Provisions.
Clarifications to the Project Special Provisions:
A. Clarification to Section 609 — Curb and Gutter
■ Addendum #2 is revised to clarify when tie bars are required between the curb/gutter
and the concrete pavement. Tie bars will not be required if curb and gutter is placed
monolithic with the concrete paving. Tie bars will be required if there is a
construction joint between the curb/gutter and the pavement. In both cases, the pan
thickness along concrete paving will be the depth of the pavement which is 11
inches.
Please contact John D. Stephen, CPPO, LEED AP, Senior Buyer at (970) 221-6777 with any
questions regarding this addendum.
RECEIPT OF THIS ADDENDUM MUST BE ACKNOWLEDGED BY A WRITTEN STATEMENT
ENCLOSED WITH THE BID/QUOTE STATING THAT THIS ADDENDUM HAS BEEN
RECEIVED.
April 30, 2009
6
REVISION OF SECTIONS 105 AND 106
CONFORMITY TO THE CONTRACT OF
PORTLAND CEMENT CONCRETE PAVEMENT
(COMPRESSIVE STRENGTH CRITERIA)
Table 106-3
TESTING SCHEDULE - ITEM 412 PORTLAND CEMENT CONCRETE PAVEMENT
Minimum Testing Frequency
Element Contractor's Quality Control
Aggregate Gradation Minimum of 1/day, then 1/10,000 sq. yds... ,
and Fractured Faces
Slump First three loads each day, then as needed for control.
Compressive Strength,
Air Content, Yield and Minimum of 1/day, then 1/2,500 sq. yds.
Sand Equivalent
Pavement Thickness I In accordance with subsection 412.21.
Minimum of six transverse and six longitudinal joint
Pull Test Joints locations for the 1 s` 2500 linear feet, then three transverse
and three longitudinal' joints thereafter.
Load Transfer Dowel Minimum of six transverse joint locations in each 2500
Bar Placement linear feet.
Tining Depth 528 linear feet in each lane and shoulder wider than 8 feet.
Water Cement Ratio First three loads each day, then 1/500 cu. yds.
Rev 10/20/07
SECTION 00400
SUPPLEMENTS TO BID FORMS
00410 Bid Bond
00420 Statement of Bidder's Qualifications
00430 Schedule of Subcontractors
Section 00410 Page 1
PROJECT:
SECTION 00300
BID FORM
City of Fort Collins
Place 215 N. Mason St. Fort Collins, Co. 80522
Date 04/16/2010
1 . In compliance with your Invitation to Bid dated 03 18 , 20 10 and
subject to all conditions thereof, the undersigned
a (Corporation, Limited Liability Company, Partnership, Joint Venture, or
Sole Proprietor) authorized to do business in the State of Colorado
hereby proposes to furnish and do everything required by the Contract
Documents to which -this refers for the construction of all items listed
on the following Bid Schedule or Bid Schedules.
2. The undersigned Bidder does hereby declare and stipulate that this
proposal is made in good faith, without collusion or connection with any
other person or persons Bidding for the same Work, and that it is made in
pursuance of and subject to all the terms and conditions of the
Invitation to Bid and Instructions to Bidders, the Agreement, the
detailed Specifications, and the Drawings pertaining to the Work to be
done, all of which have been examined by the undersigned.
3. Accompanying this Bid is a certified or cashier's check or standard Bid
bond in the sum of 5%
($ ) in accordance with the Invitation To Bid and Instructions
to Bidders.
4. The undersigned Bidder agrees to execute the Agreement and a Performance
Bond and a Payment Bond for the amount of the total of this Bid within
fifteen (15 ) calendar days from the date when the written notice of the
award of the contract is delivered to him at the address given on this
Bid. The name and address of the corporate surety with which the Bidder
proposes to furnish the specified performance and payment bonds is as
follows: Liberty Mutual Insurance Co.
5.• All the various phases of Work enumerated in the Contract Documents with
their individual jobs and overhead, whether specifically mentioned,
included by implication or appurtenant thereto, are to be performed by
the CONTRACTOR under one of the items listed in the Bid Schedule,
irrespective of whether it is named in said list.
6. Payment for Work performed will be in accordance with the Bid Schedule or
Bid Schedules subject to changes as provided in the Contract Documents.
7. The undersigned Bidder hereby acknowledges receipt of Addenda No.
001 through 003
Rev 10/20/07
Section 00300 Page 1
7127 College/Harmony Intersection Improvements Federal Aid Project No. STU M455-077
Addendum 2
Line Item p Line Item Description
Estimated
Quantities
Unit
Unit Price
Total Cost
201-00000
Clearing and Grubbing
1
Ls
3,916.77
3,916.77
202-00019
Removal of Inlet
3
EA
395.76
1,187.28
202-00035
Removal of Pie
46
LF
23.82
1,095.72
202-00200
Removal of Sidewalk
1,683
Sy
1 1.84
3,096.72
202-00203
Removal of Curb and Gutter
6,792
LF
1.04
7,063.68
202-00210
Removal of Concrete Pavement
803
SY
3.42
2,746.26
202-00211
Removal of Median Cover
860
sY
2.50
2 150. 00
202-00220
Removal of Asphalt Mat
16,544
SY
4.37
72,297.28
202-00240
Removal of Asphalt Mat(Planing)
4,944
SY
1.44
7,119.36
202-00900
Removal of Concrete Footing (Signal Pole Base -
To 36"
8
EA.
272.34
2,178.72
203-00010
Unclassified Excavation (Complete In Place
5,494
CY
4 • 33
23, 789.02
203-00100
Muck Excavation
100
CY
27.95
2,795.00
203-01596
Potholing With Surveying and Stationing of U/G
Utilities
1
LS
9,545.21
9,545.21
207-00205
Topsoil
173
CY
14.13
2,444.49
207-00210
Stockpile Topsoil
595
CY
3.57
2,124.15
207-00405
Topsoil Special
830
CY
14.28
11,852.40
208-00003
Erosion Log Wattle (18 Inch)
12
EA
66.30
795.60
208-00020
Silt Fence
846
LF
.84
710.64
208-00045
Concrete Washout Structure
4
EA
1,070.99
4,283.96
208-00050
Storm Drain Inlet Protection (Type 1
7
EA
29.14
203.98
208-00070
Stabilized Construction Entrance
4
EA
599.76
2,399.04
208-00205
Erosion Control Supervisor
75
HR
27.50
2,062.50
209-00000
Water (Irrigation)
4,000
GAL
.33
1,320.00
210-00002
Reset Structure Brick Bollards
2
EA
1,127.09
2,254.18
7127 College/Harmony Intersection Improvements Federal Aid Project No. STU M455-077
Arid-d- �
210-00003
Reset Existinq Irrigation Backflow Preventer
2
EA
1,376.99
2,753.98
210-00004
Adjust Existing Irrigation Backflow Preventer
1
EA
204.00
204.00
210-00050
Reset Fire Hydrant
2
EA
4,258.47
8,516.94
210-00065
Reset Monument
1
EA
277.00
277.00
210-04010
Adjust Manhole
9
EA
484.75
4,362.75
210-04015
Modify Manhole
2
EA
994.49
1,988.98
210-04050
Adjust Valve Box
12
EA
242.37
2,908.44
210-04060
Adjust Water Meter
2
EA
403.92
807.84
212-00050
Sod
15,000
SF
.46
6,900.00
304-06000
Aggregate Base Course (Class 5 or 6)
7,435
TON
13.71
101,933.85
403-00001
Hot Mix Asphalt Tem orar11"
135
TON
72.74
9,819.90
403-00720
Hot Mix Asphalt (Patching) (Asphalt) (6")
245
TON
127.36
31, 203.20
403-32821
Hot Mix Asphalt (Grading SG) (100) (PG 58-28)
(4" Depth)
974
TON
52.21
55, 722.54
403-33851
Hot Mix Asphalt (Grading S) (100) (PG 64-28) (2"
Depth)
487
TON
77.51
37 747.37
403-33852
Hot Mix Asphalt (Grading S) (100) (PG 64-28) (Y
Depth)(Overlay)
85SI
TON
77.00
65 835.00
412-00801
Concrete Pavement (8 Inch)(S ecial-Driveways)
193
SY
44.11
8,513.23
412-01100
Concrete Pavement (11 Inch)
11,930
SY
50.99
608, 310. 70
412-01101
Concrete Pavement (11 Inch) (Special-
Crosswalks)
835
SY
92.96
77, 621.60
412-01102
Concrete Pavement (11 Inch) (Special -Raised
Crosswalks)
118
SY
98.06
11,571.08
412-01120
Concrete Pavement (11 inch) (Fast Track) (24
Hour)
50
SY
35.86
1,793.00
412-01121
Concrete Pavement (11 inch) (Fast Track) (48
Hour)
50
sY
35.16
1,758.00
420-00500
Geotextile(Paving)
7,024
SY
1.76
12,362.24
506-01020
Geo rid Reinforcement
500
SY
3.22
1,610.00
603-01155
15 Inch Reinforced Concrete Pipe (Complete In
Place)
51
LF
86.14
4,393.14
603-01185
18 Inch Reinforced Concrete Pipe (Complete In
Place)
23
LF
38.35
882.05
7127 College/Harmony Intersection Improvements Federal Aid Project No. STU M455-077
Addendum 2
603-01245
24 Inch Reinforced Concrete Pipe (Complete In
Place)
40
LF
109.09
4,363.60
604-16050
Inlet Type 16 (Single) (Special)
2
EA
4.003.47
8,006.94
604-16505
Inlet Type 16 Double 5 Foot
1
EA
604-19315
Inlet Type R L 15 15 Foot)
1
EA
7,627.51
7,627.51
604-30010
Manhole Slab Base 4' Diameter 10 Foot)
1
EA
1 , 657.49
1,657.49
604-30015
Manhole Slab Base 5 Diameter 15 Foot
1
EA
3,439.42
3,439.42
604-xxxxx
Snout Structure
4
EA
693.60
2,774.40
605-00004
4 Inch Non -Perforated Pie Underdrain
210
LF
31.62
6,640.20
605-00040
4 Inch Perforated Pie Underdrain
1,992
LF
11.37
22, 649.04
608-00005
Concrete Sidewalk (Special -Thickened Ede
88
SY
43.76
3,850.88
608-00350
Concrete Sidewalk Colored
293
SY
42.90
12, 569. 70
608-00006
Concrete Sidewalk 6 Inch
1,111
SY
29.58
32 863. 38
608-00010
Concrete Curb Ramp
335
SY
103.71
34,742.85
608-10010
Sidewalk Drain
1
EA
1881.89
1.881.89
609-21010
Curb and Gutter Type 2 Section I-B)
1,149
LF
13.89
15, 959. 61
609-21011
Curb and Gutter Type 2 Section I-B Modified
2,772
LF
23,93
66,333.96
609-21020
Curb and Gutter Type 2 Section II-B
2,822
LF
15.92
44, 926.24
609-21011
Curb and Gutter Type 2 (Section I-M)
755
LF
13.79
10,411.45
610-00010
Median Cover Material Decorative
747
SF
7. 23m
5,400.81
613-00200
2 Inch Electrical Conduit
1,125
LF
4.28
4,815.00
613-00201
2 Inch Electrical Conduit - Irrigation Sleeve
410
LF
4.28
1,754.80
613-00300
3Inch Electrical Conduit
2,400
LF
4.69
11 256.00
620-00002
Field Office Class 2
1
EA
6,383.12
6,383.12
620-00020
Sanitary Facility
2
EA
] 14. 00
1,428.00
622-00270
Bollard
24
EA
193.80
4,651.20
7127 College/Harmony Intersection Improvements Federal Aid Project No. STU M455-077
Aaaenaum
c
626-00000
Mobilization
1
LS
174,500.00
174,500.00
626-01000
Public Information Services
1
LS
439.99
439.99
627-00025
4 inch Pavement Markin Tape Removable
2,400
LF
.25
600.00
630-80000
Construction Traffic Control Devices
1
LS
19.696.07
19,696.07
Flagging
1,600
Hour
22.95
36 720.00
630-00000
630-00012
Traffic Control Management
Construction Traffic Sin Panel Size A)
134
15
Da
EA
346.80
76.50
46,471.20
1 .147.5 0
63 880341
630-80342
Construction Traffic Sin Panel Size B
Portable Message Sign Panel
Concrete Barrier (Temporary)
15
90
300
EA
EA/
Da
LF
86.70
76.50
24.48
1,300.50
6 885.00
7,344.00
630-80359
630-80370
630-86800
Traffic Signal (Temporary) - College and
Harmon Intersection
1
LS
27 776.40
27 776.40
630-86801
Traffic Signal (Temporary) - College and Mason
Intersection
FORCE ACCOUNT
1
LS
2 $ 55..69
26,855.69
700-70010
F/A Minor Contract Revisions
F/A Partnering
1
1
FA
FA
$ 145,000.00
$ 5,000.00
$ 145,000.00
$ 5,000.00
700-70011
700-70014
F/A Incentive
1
FA
$ 115,000.00
$ 115,000.00
700-70016
F/A Fuel Cost Adjustment
1 FA $ 25,000.00 $ 25,000.00
F/A Concrete Pavement Incentive
F/A Asphalt Cement Cost Adjustment
F/A OJT Colorado Training Program
1 FA $ 17,000.00 $ 17,000.00
1 FA $ 25,000.00 $ 25,000.00
1 FA $ 525.00 $ 525.00
F
700-70022
700-70380 1 F/A Erosion Control
1
FA
$ 5,000.00
1 $ 5.000.00
TOTAL COST:Fs 2, 236 762 .
Two Million, Two Hundred Th;rfy Six Thnncanrl� �-- — d c
ern Niin r2r1 m wty Two nnl�ar
TOTAL IN WORDS
and Seventy Eight Cents
9. PRICES
The foregoing prices shall include all labor, materials,
transportation, shoring, removal, dewatering, overhead, profit,
insurance, etc., to - cover the complete Work in place of the several
kinds called for.
Bidder acknowledges that the OWNER has the right to delete items in
the Bid or change quantities at his sole discretion without affecting
the Agreement or prices of any item so long as the deletion or change
does not exceed twenty-five percent (25%) of the total Agreement
Price.
RESPECTFULLY SUBMITTED:
Lafarge North America dba
Lafarge West, Inc.
CONTRACTOR
BY: Kenneth R. Ball
04/16/2010
i�Date
General Manager
Title
00239
License Number (If Applicable)
(Seal - if Bid is by corporation)
Attest:
Patrese E. Yar ugh
Address 00 N. Taft Hill Rd.
Fort Collins, Co. 80521
Telephone 970 407-3600
Email ken.ball@lafarge-na.com
Rev10/20/07 Section 00300 Page 5
SECTION 00410
BID BONA
Lafarge North America, Inc. dba
KNOW ALL MEN BY THESE PRBSENTS: that we, the undersigned Lafarge West, Inc.
as Principal., and as Surety, are hereby held and firmly bound unto the City of
Fort Collins, Colorado,_ as _ OWNER, in the sum of $ Five Percent (5%) of Amount Bidfor the
payment of which, well and truly to be made, we hereby jointly and severally
bind ourselves, successors, and assigns.
THE CONDITION of this obligation is such that whereas the Principal has
submitted to the City of Fort Collins, Colorado the accompanying Bid and
hereby made a part hereof to enter into a Construction Agreement for the
construction of Fort Collins Project, 7127 College/Harmony Intersection
Improvements Federal Aid Project No. STU M455-077.
NOW THEREFORE,
(a) If said Bid shall be rejected, or
(b) If said Bid shall be accepted and the Principal shall execute and deliver.
a Contract in. the form of Contract attached hereto (properly completed in
accordance with said Bid) and. shall furnish a BOND for his faithful °'-
performance of said Contract, and for payment of all persons performing
labor or furnishing materials in connection therewith, and shall in all
other respects perform the agreement created. by the acceptance of said
Bid, then this obligation shall be void; otherwise: the same shall remain
in foxce and effect, it being expressly understood and agreed that the
liability of the Surety for any and all claims hereunder shall, in no
event, exceed the penal amount of this obligation as herein stated.
The Surety, for value received, hereby stipulates and agrees that the
obligations of said Surety and its BOND shall be in no way impaired or
affected by any extension of the time within which the OWNER may accept such
Bid; and said Surety does hereby waive notice of.any such extension.
Surety Companies executing bonds must, be authorized to transact business in
the State of Colorado and be accepted by the OWNER.
ReVIMC107 Section 00410 Rage 2
IN WITNESS WHEREOF, the Principal and the Surety have hereunto set their hands
and seals this 29th day of. March , 201Q, and such of them as are
corporations have caused their corporate seals to be hereto affixed and these
presents to be signed by their proper officers, the day and year first set
forth above.
PRITcxPAL
Lafarge North America, Inc.
Name: dba Lafarge West Inc
ATTEST:
By: (�
o.
SURETY
1400 American Lane
Hy : ("
Sandra E. Bronson
Title: Attorney -in -Fact
j/Cs F h
r;
(SEAL)
Rev10120107 Section 00410 Page 3
i
Financial Services
City
Purchasing Division
215 N. Mason St. 2"d Floor
PO Box 580
'IF olions
t Collins, CO 80522
ForOn
970.221.6775
970.221.6707
k P �rc ZIn
fcgov.com/Purchasing
ADDENDUM No. 2
SPECIFICATIONS AND CONTRACT DOCUMENTS
Description of Bid 7127:,College/Harmony Intersection Improvements
Federal Aid Project No. STU M455-077
OPENING DATE: 3:00 P.M. (Our Clock) April 16, 2010
To all prospective bidders under the specifications, and contract documents described above, the
following changes are hereby made.
CHANGE:
A. Revision of Section 620, Field Facilities
Line Item 620-00002 Field Office (Class 2);is added to the bid tab.
I
Pay Item Pay Quantity Pay Unit
620-00002 Field Office (Class 2) 1 EA
B. Revision of Section 630, Traffic Control
Line Item 630-80359 Portable Message Sign Panel Pay item is revised to EA / DAY on the
bid tab.
Pay Item Pay Quantity Pay Unit
630-80359 Portable Message Sign Panel 90 EA / DAY
C. Revision of Force Account
Line Item 700-70017 Concrete Pavement Incentive is added to the contract for Pavement
Incentive Payment based on Compressive Strength Criteria in Standard Special
Pay Item Pay Unit Unit Price Total Cost
700-70017 Concrete Pavement Incentive FA $17,000 $17,000
Revisions to the Project Special Provisions:
A. Revision to Section 506 — Geosynthetics
The project special for item 506-01020 Geogrid Reinforcement will meet the following
specifications:
• Minimum Mass per Unit Area: 5 OZ / SY
• Minimum Peak Tensile Strength: 850 LB/ FT
• Minimum Tensile Strength at 2% Strain: 275 LB / FT
• Minimum Junction Efficiency: 90%
Power of Attorney
FIDELITY AND DEPOSIT COMPANY OF MARYLAND
KNOW ALL MEN BY THESE PRESENTS: That the FIDELITY AND DEPOSIT COMPANY OF MARYLAND, a
corporation of the State of Maryland, by M. P. HAMMOND, Vice President, and GREGORY E. MURRAY, Assistant
Secretary, in pursuance of authority granted by Article VI, Section 2, of the By -Laws of said y, which are set forth on
the reverse side hereof and are hereby certified to be in full force and effect on the d ereby nominate,
constitute and appoint Richard G. DICCIANI, Darella E. WHITE, D R rd A. JACOBUS,
Mary C. O'LEARY, Sandra E. BRONSON, Maureen M ancy K. WALLACE,
all of Philadelphia, Pennsylvania, EACH its true a n - make, execute, seal and
deliver, for, and on its behalf as surety, a ts� e A and undertakings, and the execution of
such bonds or undertakings in p tlib�e pre a "'���m___g upon said Company, as fully and amply, to all
intents and purpose$�ha b %duj y t owledged by the regularly elected officers of the Company at
its office in Baltimo3j , m sons. This power of attorney revokes that issued on behalf of Richard G.
DICCIANI, Darella�D WHEELER, Richard A. JACOBUS, Mary C. O'LEARY, Sandra E. BRONSON,
Maureen E. MCNEI e G. MCVAUGH, Nancy K. WALLACE, dated June 13, 2006.
The said Assistant Secretary does hereby certify that the extract set forth on the reverse side hereof is a true copy of Article VI,
Section 2, of the By -Laws of said Company, and is now in force.
IN WITNESS WHEREOF, the said Vice -President and Assistant Secretary have hereunto subscribed their names and
affixed the Corporate Seal of the said FIDELITY AND DEPOSIT COMPANY OF MARYLAND, this 20th day of June,
A.D. 2006.
ATTEST:
FIDELITY AND DEPOSIT COMPANY OF MARYLAND
'gyp Dfpo'si
ti �p O
�, •wry ;
W
Gregory E. Murray Assistant Secretary M. P. Hammond Vice President
State of Maryland 1
3 C v o Baltimore
f ss.
�.
.Oth day of June, A.D. 2006, before the subscriber, a Notary Public of the State of Maryland, duly
cominIS ' t ed'and qualified, came M. P. HAMMOND, Vice President, and GREGORY E. MURRAY, Assistant Secretary of
ITY AND DEPOSIT COMPANY OF MARYLAND, to me personally known to be the individuals and officers
in and who executed the preceding instrument, and they each acknowledged the execution of the same, and being
�ytrnbAuly sworn, severally and each for himself deposeth and saith that they are the said officers of the Company aforesaid,
"and at the seal affixed to the preceding instrument is the Corporate Seal of said Company, and that the said Corporate Seal
and their signatures as such officers were duly affixed and subscribed to the said instrument by the authority and direction of
the said Corporation.
IN TESTIMONY WHEREOF, I have hereunto set my hand and affixed my Official Seal the day and year first above
written.
IC•
Maria D. Adamski Notary Public
My Commission Expires: July 8, 2011
POA-F 156-0735
EXTRACT FROM BY-LAWS OF FIDELITY AND DEPOSIT COMPANY OF MARYLAND
"Article VI, Section 2. The Chairman of the Board, or the President, or any Executive Vice -President, or any of the Senior
Vice -Presidents or Vice -Presidents specially authorized so to do by the Board of Directors or by the Executive Committee,
shall have power, by and with the concurrence of the Secretary or any one of the Assistant Secretaries, to appoint Resident
Vice -Presidents, Assistant Vice -Presidents and Attorneys -in -Fact as the business of the Company may require, or to
authorize any person or persons to execute on behalf of the Company any bonds, undertaking, recognizances, stipulations,
policies, contracts, agreements, deeds, and releases and assignments of judgements, decrees, mortgages and instruments in
the nature of mortgages,...and to affix the seal of the Company thereto."
CERTIFICATE
I, the undersigned, Assistant Secretary of the FIDELITY AND DEPOSIT COMPANY OF MARYLAND, do hereby certify
that the foregoing Power of Attorney is still in full force and effect on the date of this certificate; and I do further certify that
the Vice -President who executed the said Power of Attorney was one of the additional Vice -Presidents specially authorized
by the Board of Directors to appoint any Attorney -in -Fact as provided in Article VI, Section 2, of the By -Laws of the
FIDELITY AND DEPOSIT COMPANY OF MARYLAND.
This Power of Attorney and Certificate may be signed by facsimile under and by authority of the following resolution of the
Board of Directors of the FIDELITY AND DEPOSIT COMPANY OF MARYLAND at a meeting duly called and held on
the 1 Oth day of May, 1990.
RESOLVED: "That the facsimile or mechanically reproduced seal of the company and facsimile or mechanically
reproduced signature of any Vice -President, Secretary, or Assistant Secretary of the Company, whether made heretofore or
hereafter, wherever appearing upon a certified copy of any power of attorney issued by the Company, shall be valid and
binding upon the Company with the same force and effect as though manually affixed."
IN TESTIMO�NI,Y WHEREOF, I have hereunto subscribed my name and affixed the corporate seal of the said Company,
this a� r \ day of / r ► k(1� o'� i �• '
f.
Assistant Secretary
....................
• i
FIDELITY AND DEPOSIT COMPANY
OF MARYLAND
3910 KESWICK ROAD, BALTIMORE, MD 21211-2226
Statement of Financial Condition
As Of December 31, 2008
ASSETS
Bonds............................................................................................................................................... $ 148,252,979
Stocks............................................................................................................................................... 23,313,771
Cash and Short Term Investments................................................................................................... 7,904,491
ReinsuranceRecoverable................................................................................................................. 5,939,089
Other Accounts Receivable.............................................................................................................. 38,307,386
TOTAL ADMITTED ASSETS........................................................................................................ $ 223,717,718
LIABILITIES, SURPLUS AND OTHER FUNDS
Reserve for Taxes and Expenses...................................................................................................... $ 597,566
Ceded Reinsurance Premiums Payable............................................................................................ 38,399,492
Securities Lending Collateral Liability............................................................................................ 6,094,921
TOTALLIABILITIES.................................................................................................................... $ 45,091,979
Capital Stock, Paid Up........................................................................................ $ 5,000,000
Surplus................................................................................................................ 173,625,739
Surplus as regards Policyholders...................................................................................................... 178,625,738
TOTAL...................................................................................................................................... $ 223,717,718
Securities carried at $38,306,550 in the above statement are deposited as required by law.
Securities carried on the basis prescribed by the National Association of Insurance Commissioners. On the basis of
December 31, 2008 market quotations for all bonds and stocks owned, the Company's total admitted assets would be
$216,398,425 and surplus as regards policyholders $171,306,445.
I, DENNIS F. KERRIGAN, Corporate Secretary of the FIDELITY AND DEPOSIT COMPANY OF MARYLAND, do hereby
certify that the foregoing statement is a correct exhibit of the assets and liabilities of the said Company on the 31st
day of December, 2008.
'110 Secretary
State of Illinios
City of Schaumburg SS:
Subscribed and swom to, before me, a Notary Public of the State of Illinois, in the City of Schaumburg, this 14th day of March, 2009.
Notary Public
v 1"
={�'ir '"3b i4]ARLO G. Sd.klA•.3`!N `t
Aorr�c�ntl P,tif COA?!: iSSiON EXViRcS{,
SECTION 00420
STATEMENT OF BIDDER'S QUALIFICATIONS
All questions must be answered and the data given must be clear and
comprehensive.. This statement must be notarized. If necessary, questions may
be answered on separate attached sheets. The Bidder may submit any additional
information he desires.
1.
Name of Bidder: Lafarge
North America dba Lafarge West, Inc.
1800 N.
Taft Hill Rd.
2.
Permanent main office address:
Fort Collins,
Co. 80521
3.
When organized: Dec. 2001
4.
If a corporation, where
incorporated:
Delaware
5.
How many years have you
been engaged in
the contracting business
under your present firm
or trade name?
9 Yearg
6. Contracts on hand: (Schedule these, showing the amount of each
contract
and the appropriate
anticipated dates
of completion.)
City of
Greeley 2010
$
One Million
Fall 2010
City of
Estes Pk. 2010
$
900,000
Summer 2010
E. Harmony Bridge
$
1.5 Million
SSummer 2010
Citv of
Fort Collins Overlav
$
1.4 Million
Fall 2010
7. General character of Work performed by your company:
Asphalt Paving, Aggregates, Ready Mix Sales
8. Have you ever failed to complete any Work awarded to you? No
If so, where and why?- N/A
9. Have your ever defaulted on a contract?
If so, where and why? N/A
10. Are you debarred by any government agency?
If yes list agency name. N/A
No
No
Rev10/20/07 Section 00420 Page 1
11. List the more important projects recently completed by your company,
stating the approximate cost of each, and the month and year completed,
location and type of construction.
Wal-Mart Supercenter $1.7 Million April 2009 Fort Collins Parking Lot
Lemay Ave Widening $2.1 Million Sept. 2008 Fort Collins _Street Widening
City of Greeley 2009 Overlay Project $ 1.8 Million Dec 2009 Greeley Street
Repair
12. List your major equipment available for this contract.
Please see the attachPd 1; Gt of
13. Experience in construction Work similar in importance to this
project:
City of Fort Collins Overlay Projects
Larimer Coutny Round-abouts at Taft Hill Rd and Vine
Harmony / Ziegler Widening
14. Background and experience of the principal members of your organization,
including officers:
Steven B. Peterson Vice President 20+ Years
Kenneth R. Ball General Manager 9+ Y.arG
Bob Tews Operations Manager 30+ Yearg
15. Credit available: $ Unlimited
16. Bank reference: Wells Fargo Bank 1800 289-3557
17. will you, upon request, fill out a detailed financial statement and
furnish any other information that may be required by the OWNER?
18. Are you licensed as a General CONTRACTOR? Yes
If yes, in what city, county and state? FT. Collins. Larimer CountyWhat
class, license and numbers? General Contractor's 7.;c_ # 00239
19. Do you anticipate subcontracting Work under this
Contract? Yes
If yes, what percent of total contract? Please see schedule of subcontractors
and to whom?
20. Are any lawsuits pending against you or your firm at this time? No
IF yes, DETAIL N/A
Rev10/20/07 Section 00420 Page 2
LAFARGE WEST, INC. EQUIPMENTLIST
ASPHALT PLANTS —4
4 Oil Distributors
18 Field Conveyors
2 Draglines
SPRAYERS
11 Light plants & Generators
14 Conveyors, portable
17 Silos
3 Baghouses
TRUCKS & AUTOMOBILES
22 Passenger Cars
10 Single Axle Mechanic's
2 Single Axle FlatBeds
1 Tandem Flatbed
7 Single Axle Water
4 Single Axle Water
.2 Tilt Trailers
40 Pickup Trucks
7 Tandem Patch Trucks
.6 Tandem Water Trucks
22 Tandem Dump Trucks
30 Over -the -Road
2 Gravel Tailers
1 Gravel Tractors
10 Tool Trailers
7 Oil Trailers
1 4000 Gallon Water
1 Pipe Trailer
8 Lab & Office Trailers
5 Loboy & Hiboy Trailers
1 Rock Trailers
3 Single Axle Fuel Trucks
7 1-Ton w/Dist.-Tanks
TRACTOR— CRAWLERS
2 Farm Tractors
1 634 CAT Dozer
LOADERS
1 5 Michigan Loader
1 75A Michigan Loader'.
TRAILERS W/RAMPS
1 AC Loader
TERRAIN HYDRA CRANE
1 125 Michigan Loader
1 175B Michigan Loader
2 966 CAT Loader
1 275B Michigan Loaders
TRUCKS
3 920 CAT Loaders
TRUCKS
7 910 CAT Loaders
TRUCKS
2 936 CAT Loaders
1 950 CAT Loader
TRACTORS
3 Scoopmobiles
1 '224 CAT Loader .
COMPACTORS
2 Vibro Plate Compactors
CAT 815
WEIGHING EQUIPMENT
1 Scales
4 Ramsey Belt Scales
SCRAPERS
5 613 CAT Scraper
ROAD WIDENERS
1 Blaw Knox Road Widener
RAILROAD CARS
35 Gondola Type Cars
21. What are the limits of your public liability? DETAIL
$17 Million
What company? Liberty Mutual Surety Co.
22. What are your company's bonding.limitations? $225 Million
23. The undersigned hereby authorizes and requests any person, firm or
corporation to furnish any information requested by the OWNER in
verification of the recital comprising this Statement of Bidder's
Qualifications.
Dated at Noon this 16th day of April , 2010.
Lafarge North America dba
Lafarge Wes nc .
Name pf d
By:
Ke no-th R. a
Title: General Manager
State of Colorado
County of Larimer
Kenneth R. BAll being duly sworn deposes and says that he
is General Manager of Lafarge North America dba and that
(name of organization) Lafarge West, Inc.
the answers to -the foregoing questions and all statements therein contained
are true and correct.
Subscribed and sworn to before me this 16th day of
'�7 /a
E "n� —
Notary Public
My commission expires
Rev 10/20/07
March 28, 2013
ril , 2010 .
��1111111/I
•••........•
��.. NOTq� 'p op
,t •O—
V�tic
Ol OIC •••••••..•••••• O ``�
Section 00420 Page 3
SECTION 00430
SCHEDULE OF SUBCONTRACTORS
List all subcontractors for the work items listed below and all subcontractors
performing over 150 of the contract.
ITEM
Concrete
Dirt & Utilities
Traffic Control
Asphalt Removal
Temp Traffic Signals
Erosion Control
Landscaping
1
SUBCONTRACTOR
Gerrard Excavation
Quality Traffic Control
Alpha Milling
W.L Contractors
All Terrain Erosion Control
A & M Landscaping
Section 00430 Page 1
COLORADO DEPARTMENT OF TRANSPORTATION PROJECT
ANTI-COLLUSION AFFIDAVIT souU
M4 —
LOCATION
College / Harmony Intersection
I hereby attest that I am the person responsible within my firm for the final decision as to the price(s) and amount of this
bid or, if not, that I have written authorization, enclosed herewith, from that person to make the statements set out below on
his or her behalf and on behalf of my firm.
I further attest that:
1. The price(s) and amount of this bid have been arrived at independently, without consultation, communication or
agreement for the purpose or with the effect of restricting competition with any other firm or person who is a bidder
or potential prime bidder.
2A. Neither the price(s) nor the amount of this bid have been disclosed to any other firm or person who is a bidder or
potential prime bidder on this project, and will not be so disclosed prior to bid opening.
2B. Neither the prices nor the amount of the bid of any other firm or person who is a bidder or potential prime bidder on
this project have been disclosed to me or my firm.
3A. No attempt has been made to solicit, cause or induce any firm or person who is a bidder or potential prime bidder to
refrain from bidding on this project, or to submit a bid higher than the bid of this firm, or any intentionally high or non-
competitive bid or other form of complementary bid.
3B. No agreement has been promised or solicited for any other firm or person who is a bidder or potential prime bidder
on this project to submit an intentionally high, noncompetitive or other form of complementary bid on this project.
4. The bid of my firm is made in good faith and not pursuant to any consultation, communication, agreement or
discussion with, or inducement or solicitation by or from any firm or person to submit any intentionally high, noncom-
petitive or other form of complementary bid.
5. My firm has not offered or entered into a subcontract or agreement regarding the purchase or sale of materials or
services from any firm or person, or offered, promised or paid cash or anything of value to any firm or person,
whether in connection with this or any other project, in consideration for an agreement or promise by any firm or
person to refrain from bidding or to submit any intentionally high, noncompetitive or other form of complementary bid
or agreeing or promising to do so on this project.
6. My firm has not accepted or been promised any subcontract or agreement regarding the sale of materials or
services to any firm or person, and has not been promised or paid cash or anything of value by any firm or person,
whether in connection with this or any other project, in consideration for my firm's submitting any intentionally high,
noncompetitive or other form of complementary bid, or agreeing or promising to do so, on this project.
7. 1 have made a diligent inquiry of all members, officers, employees, and agents of my firm with responsibilities
relating to the preparation, approval or submission of my firm's bid on this project and have been advised by each of
them that he or she has not participated in any communication, consultation, discussion, agreement, collusion, or
other conduct inconsistent with any of the statements and representations made in this affidavit.
8. 1 understand and my firm understands that any misstatement in this affidavit is and shall be treated as a fraudulent
concealment from the Colorado Department of Transportation, of the true facts relating to submission of bids for this
contract.
I DECLARE UNDER PENALTY OF PERJURY IN THE SECOND DEGREE, AND ANY OTHER APPLICABLE STATE OR
FEDERAL LAWS, THAT THE STATEMENTS MADE ON THIS DOCUMENT ARE TRUE AND COMPLETE TO THE BEST
OF MY KNOWLEDGE.
Contractor's firm or company name
By
Date
Lafarge North America dba
enneth . Ball
�04/21Z10
Title
General Manager
Lafarge West, Inc.
2nd contractor's firm or company name. (if joint venture.)
By
Date
Title
N/A
Sworn to before me this 21 -day of, ril \��X��� "t q���/t,� 2010
\� Y
Notary Public
Patrese E. Yarbrough
���•� •�pTAIgY •�•O/ i
V^^
v+
My commission expires
03/28/13
�N'• ' 0
pUB4�G Z
NOTE: This document must be signed in ink.
e� ��.•••• ••.•'Q�`�
1I OF co�.� \� CDOT Form #606 1/02
COLORADO DEPARTMENT OF TRANSPORTATION Project No.: STU M455-077
BIDDERS LIST DATA and UNDERUTILIZED College Harmony Intersection
DBE (UDBE) BID CONDITIONS ASSURANCE Location:Fort Collins, Co.
Prime Contractor Instructions: This form has two sections, both must be completed and submitted with your bid. Complete Section
to list all subcontract quotes received (non -DBE and DBE). Complete Section II to report only Underutilized DBE (UDBE) participation
percentages which qualify under the contract goal specification for this project. Please review CDOT Form #715 instructions before
completing Section II. Attach additional sheets as necessary.
POLICY
It is the policy of the Colorado Department of Transportation that underutilized disadvantaged business enterprises have equal
opportunity to participate on projects financed with federal, state or local entity funds. Consistent with 49 Code of Federal Regulations
(CFR) Part 26.11, the Bidders List data provided by the Contractors will provide CDOT as accurate data as possible about the
universe of DBE and non -DBE firms actively seeking work on its highway construction contracts, for use in setting overall DBE goals.
SECTION I: CDOT BIDDERS LIST INFORMATION (Non -DBEs and DBEs)
1) Are all subcontract bids (quotes) received by your firm for this project listed below? ® Yes ❑ No
2) If No, make certain any additional subcontract bidding information is submitted to the CDOT Business.Prog rams Office
before 4:00 pm on the day after bids are opened to ensure CDOT has the best data possible for setting future DBE goals
(use the same table format as below):
CDOT Business Programs Office
4201 E. Arkansas Ave., Room 200
Denver, Colorado 80222 FAX: 303-757-9019 EMAIL: eo@dot. state. co. us
3) The most recent CDOT Bidders List will be posted online at: www.dot.state.co.us/EEO/DBEProgramPage.htm
NAME OF FIRM
SUBMITTING BID/QUOTE
CERTIFIED
DBE FIRM?
WORK ITEM(S) DESCRIPTION
FIRM
BEING USED?
1
El Yes El No
Concrete
Yes ❑ No
CG&S
Fj Ma be
y
2. Gerrard
,I] Yes ®
Dirt & Pipe
Yes ❑ NoNo
[:1 Ma ybe
3. Quality Traffic
( 'Yes 0 No
Traffic Control
�] Yes ❑ No
control
❑ Ma ybe
4. Alpha Milling
[7 Yes ® No
[ Yes ❑ No
YMa e
Asphalt Removal
❑ ybe
5-W.L. Contractors
0Yes [id No
No
Temp. Traffic Signals
Yes ❑ No
❑Ye ybe
6 All Terrain Erosion
Yes ® No
Erosion Control
ki Yes ❑ No
Control
❑ Ma ybe
7. Northstar Concrete
❑ Yes U No
Concrete
El ER No
❑ Ma ybe
8. P.A.A. Concrete
®Yes El No
Concrete
El Yes �] No
❑ Ma ybe
9. Your Way
® Yes ❑ No
Traffic Control
❑ Yes $] No
❑ Ma ybe
10Lawson
❑ Yes N No
Concrete
❑ Yes K] No
❑ Ma ybe
11. Mill Brothers
❑ Yes U No
Landscaping
❑ Yes ZI No
❑ Ma ybe
12. Environmental
[jd Yes ❑ No
Erosion Control
❑ Yes i] No
Logistins
❑ Ma ybe
13.
Don Kehn
❑ Yes ® No
Asphalt Removal
El Yes &I No
❑ Ma ybe
Previous editions may not be used CDOT Form 714 Page 1 of 2 4/08
Revisions to the Project Standard Special Provisions:
A. Standard Special Provision "Conformity to the Contract of Portland Cement Concrete
Pavement (Compressive Strength Criteria) — April 30, 2009" is added to the contract.
• See Attached.
• This Standard Special Provision revises section 105.05 and allows the City of Fort
Collins to base pay factor incentive/disincentive on compressive strength criteria.
Clarifications to the Project Special Provisions:
A. Clarification to Section 203 — Excavation and Embankment
Unclassified Excavation (Complete in Place) assumes that Harmony and College
roadways have a minimum 9 inches of existing base under the existing pavement. The
City does not anticipate requiring over excavation, stockpiling and recornpacting existing
subgrade and aggregate base to obtain the assumed 9" of aggregate base.
Should a condition arise where the existing subgrade is less than 9 inches thick, the City
would address that area with the line item 203-00100 - Muck Excavation for over
excavation and disposal of shallow base and use line item 304-06000 Aggregate Base
Course (Class 5 or 6) for backfill of the excavated area in order to obtain the 9" base that
is assumed on the project.
B. Clarification to Section 609 — Curb and Gutter
• All curb and gutter that is adjacent to concrete pavement will need to be tied to the
concrete pavement with dowel bars and will need to have a pan thickness equal to the
pavement thickness which is 11 inches.
• All curb and gutter that is adjacent to asphalt pavement will be standard pan thickness of
6 inches thick.
• All curb and gutter can be poured monolithically with the pavement, but it will require tie
bars, the specified gutter pan shape and the 11 inch thick pan section.
• To simplify field measurements and comply with CDOT line item codes, all curb and
gutter will be paid under the specified bid tab line items.
C. Clarification to Section 630 — Traffic Control
• Portable Message Sign Panel — The City anticipates using portable message sign panels
for 5 days prior to each phase of construction. The City anticipates using 4 portable
message sign panels for phase 1,2, and 4. The City anticipates using 6 portable
message sign panels prior to phase 3. The pay item is EA / DAY.
REVISED BID FORM ATTACHED.
Please contact John D. Stephen, CPPO, LEED AP, Senior Buyer at (970) 221-6777 with any
questions regarding this addendum.
RECEIPT OF THIS ADDENDUM MUST BE ACKNOWLEDGED BY A WRITTEN STATEMENT
ENCLOSED WITH THE BID/QUOTE STATING THAT THIS ADDENDUM HAS BEEN RECEIVED.
., 0
NAME OF FIRM
CERTIFIED
WORK ITEM(S) DESCRIPTION
FIRM
SUBMITTING BID/QUOTE
DBE FIRM?
BEING USED?
14.
ElYes K] No
Dirt & Utilities
El Ye ® No
SEBI
El ybe
15. A&M Landscaping
ElYes KI No
Landscaping
® Yes ❑ No
❑ Ma ybe
16.
❑ Yes ❑ No
❑ Yes ❑ No
❑ Ma ybe
17.
❑ Yes ❑ No
❑ Yes ❑ No
❑ Ma ybe .
18.
❑ Yes ❑ No
❑ Yes ❑ No
❑ Ma ybe
19.
❑ Yes ❑ No
❑ Yes ❑ No
❑ Ma ybe
20.
❑ Yes ❑ No
❑ Yes ❑ No
❑ Ma ybe
SECTION IL UNDERUTILIZED DBE (UDBE) PARTICIPATION COMMITMENT
1) Total eligible Underutilized DBE (UDBE) percentage amount from Box A below: 24 . 9 %
2) Will your company's Underutilized DBE (UDBE) participation commitment meet the contract goal?] Yes ❑ No
3) List the UDBE firms, committed work items, and eligible UDBE percentage of your bid committed to each.
UDBE FIRM NAME
CERTIFICATION
COMMITTED
% COMMITMENT
NUMBER
WORK ITEM(S)
TOWARD DBE GOAL`
6G&S
145
Concrete
24 '9 %
2.
%
3.
%
4.
%
5.
%
BOX A: TOTAL ELIGIBLE UDBE PERCENTAGE AMOUNT (Round to nearest hundredth)--),
24 -9 %
Detailed instructions on how to calculate DBE commitment amounts are available on CDOT Form #715 and in the "Counting DBE Participation
Toward Contract Goals and CDOT's annual DBE goal" section of the "DBE — Definitions and Requirements" in the Standard Special Provisions.
I understand that, if my company is determined to be the low bidder for the contract on this project, I must submit a completed CDOT
Form #715 CERTIFICATION OF UNDERUTILIZED DBE PARTICIPATION for each firm listed in Section II of this form to the
Transportation Department by 4:00 pm on the third work day after the day bids are opened. The actual amounts submitted on
each CDOT Form #715 must equal or exceed the DBE percentage commitments documented on this form. In addition, if my
company does not meet the DBE/UDBE goal for this project, I must submit a completed CDOT Form #718 DBE GOOD FAITH
EFFORT DOCUMENTATION before 4:00 pm on the day after bids are opened. CDOT Form #715s submitted for firms not
included on this form, OR for amounts exceeding those listed on this form, will be accepted but NOT counted as Good Faith
Efforts. Only the efforts the contractor made prior to the bid opening will count as Good Faith Efforts.
I understand my obligation to abide by the Policy stated above Section I. 1 shall not discriminate on the basis of race, color, age, sex,
national origin, or handicap in the bidding process or the performance of contracts.
I DECLARE UNDER PENALTY OF PERJURY IN THE SECOND DEGREE, AND ANY OTHER APPLICABLE STATE OR
FEDERAL LAWS, THAT THE STATEMENTS MADE IN THIS DOCUMENT ARE TRUE AND COMPLETE TO THE BEST OF MY
KNOWLEDGE.
Company Name: Lafarge Nort Ame ' ca dba
Date: 04 / 21/ 10
Laf ar ,
Company Officer Signature: enneth R. B
Title: General Manager
Previous; editions may not be used CDOT Form 714 Page 2 of 2 4108
April 30, 2009
REVISION OF SECTIONS 105 AND 106
CONFORMITY TO THE CONTRACT OF
PORTLAND CEMENT CONCRETE PAVEMENT
(COMPRESSIVE STRENGTH CRITERIA)
NOTICE
This is a standard special provision that revises or modifies CDOT's Standard
Specifications for Road and Bridge Construction. It has gone through a formal review
and approval process and has been issued by CDOT's Project Development Branch with
formal instructions for its use on CDOT construction projects. It is to be used as written
without change. Do not use modified versions of this special provision on CDOT
construction projects, and do not use this special provision on CDOT projects in a
manner other than that specified in the instructions unless such use is first approved by
the Standards and Specifications Unit of the Project Development Branch. The
instructions for use on CDOT construction projects appear below.
Other agencies which use the Standard Specifications for Road and Bridge Construction
to administer construction projects may use this special provision as appropriate and at
their own risk.
INS"rRUCTIONS FOR USE ON CDOT CONSTRUCTION PROJECTS:
Use this standard special provision on projects having portland cement concrete
pavement where the Region Materials Engineer has determined that acceptance will
be based on compressive strength criteria.
April 30, 2009
I
REVISION OF SECTIONS 105 AND 106
CONFORMITY TO THE CONTRACT OF
PORTLAND CEMENT CONCRETE PAVEMENT
(COMPRESSIVE STRENGTH CRITERIA)
Sections 105 and 106 of the Standard Specifications are hereby revised for this project as follows:
Delete subsection 105.06 and replace with the following:
105.06 Conformity to the Contract of Portland Cement Concrete Pavement. Conformity to the Contract of all
Portland Cement Concrete Pavement, Item 412, will be determined in accordance with the following:
When the Engineer finds that the materials furnished, the work performed, or the finished product does not
conform with the Contract, or the Pay Factor (PF) for an element's process is less than 0.75 but that reasonably
acceptable work has been produced, the Engineer will determine the extent of the work that will be accepted and
remain in place. The Engineer will use a Contract Modification Order to document the justification for allowing the
work to remain in place and the price adjustment that will be applied.
When the Engineer finds the materials furnished, work performed, or the finished product is not in conformity with
the Contract, or the PF for an element's process is less than 0.75 and has resulted in an inferior or unsatisfactory
product, the work or material shall be removed and replaced or otherwise corrected by and at the expense of the
Contractor. When the PF for any process is 0.75 or greater, the finished quantity of work represented by the
process will be accepted at the calculated pay factor.
Materials will be sampled and tested by the Department in accordance with Section 106 and with procedures
contained in the Department's Field Materials Manual. The approximate quantity represented by each sample will
be as set forth in subsection 106.06, Table 106-3. Additional samples may be selected and tested at the
Engineer's discretion.
(a) Incentive/Disincentive Payments (I/DP) will be made based on a statistical analysis that yields Pay Factors
(PF) and Quality Levels (QL). The PF and QL will be made based on test results for the elements of
compressive strength and pavement thickness. Incentive/ Disincentive payment will not be made for
thickness of concrete pavement furnished by the Contractor and placed by others.
The QL will be calculated for the elements of compressive strength and pavement thickness on a process
basis. A separate process will be established for an element when a change in the process affects that
element. A process will consist of the test results from a series of random samples. Test results determined
to have sampling or testing errors will not be used. All materials produced will be assigned to a process. A
change in process is defined as a change that affects the element involved. Changes in mix design, material
source, design pavement thickness, or the method being utilized to place' the pavement are considered
changes in process. The following is provided to clarify changes in processes for each element:
1. Construction of mainline pavement, including the shoulders if placed with the mainline, is a single
process, providing there are no changes in process as described above.
2. Construction of ramps, acceleration and deceleration lanes, shoulders placed separately and areas
requiring hand work are considered separate processes.
3. A change in the mix design is a process change for the compressive strength element, but is not a
process change for the pavement thickness element.
(b) When it is necessary to represent material by one or two tests, each individual test shall have a PF computed
in accordance with the following:
If the value of the test is at or above the lower tolerance limit, then PF = 1.000. If the value of the test is
below the lower tolerance limit, then:
PF = 1.00 — [ 0.25(T,_ -TO)/V ]
where: PF = pay factor.
V= V factor from Table 105-4
To = the individual test value.
TL= lower tolerance limit.
April 30, 2009
2
REVISION OF SECTIONS 105 AND 106
CONFORMITY TO THE CONTRACT OF
PORTLAND CEMENT CONCRETE PAVEMENT
(COMPRESSIVE STRENGTH CRITERIA)
(c) The following procedures will be used to compute Incentive/Disincentive Payments (I/DP), quality levels (QL),
and pay factors (PF) for processes represented by three or more tests:
1. Quality Level (QL) will be calculated according to CP-71.
2. Compute the PF for the process. When the process has been completed, the number of tests (Pn) it
includes shall determine the formula to be used to compute the final pay factor in accordance with the
following:
A. For compressive strength and pavement thickness:
When 3_5Pn<_5
If QL >_ 85, then PF = 1.00 + (QL - 85)0.001333
If QL < 85, then PF = 1.00 + (QL - 85)0.005208
When 65Pn<_9
If QL >_ 90, then PF = 1.00 + (QL - 90)0.002000
If QL < 90, then PF = 1.00 + (QL - 90)0.005682
When 10 <_ Pn _< 25
If QL >_ 93, then PF = 1.00 + (QL - 93)0.002857
If QL < 93, then PF = 1.00 + (QL - 93)0.006098
When Pn >_ 26
If QL >_ 95, then PF = 1.00 + (QL - 95)0.004000
If QL < 95, then PF = 1.00 + (QL - 95)0.006757
3. Compute the I/DP for the process:
I/DP = (PF-1)(QR)(UP)
where: QR = Quantity Represented by the process.
UP = Unit Price bid for the Item.
The total I/DP for an element shall be computed by accumulating the individual I/DP for each process
of that element.
(d) As acceptance test results become available, they will be used to calculate accumulated QL and
Incentive/Disincentive Payments (I/DP) for each element and for the item. The Contractor's test results and
the accumulated calculations shall be made available to the Engineer upon request. The Engineer's test
results and the calculations will be made available to the Contractor as early as reasonably practical.
Numbers from the calculations shall be carried to significant figures and rounded according to AASHTO
Standard Recommended Practice R-11, Rounding Method.
I/DP will be made to the Contractor in accordance with subsection 412.24(a). During production, interim I/DP
will be computed for information only. The Pn will change as production continues and test results
accumulate. The Pn at the time an I/DP is computed shall determine the formula to be used. After all
portland cement concrete pavements have been placed according to the contract, the final I/DP will be
computed.
(e) The Contractor will not have the option of accepting a price reduction or disincentive in lieu of producing
specification material. Continued production of non -specification material will not be permitted. Material
which is obviously defective may be isolated and rejected without regard to sampling sequence or location
within a process.
April 30, 2009
3
REVISION OF SECTIONS 105 AND 106
CONFORMITY TO THE CONTRACT OF
PORTLAND CEMENT CONCRETE PAVEMENT
(COMPRESSIVE STRENGTH CRITERIA)
Table 105-4
"V" FACTORS AND INCENTIVE PAYMENTS
COMPRESSIVE STRENGTH CRITERIA
Maximum
Lower Tolerance
Element
V factor
Incentive
Limit, TL
Payment
Compressive Strength
400 psi
2.00 percent
4,200 psi
Pavement Thickness
0.4 inch
2.00 percent
Plan Thickness
-0.4 inch
(f) Sand Equivalence. The sand equivalence (SE) as determined by CP 37 will be considered acceptable when
the running average of three consecutive tests is greater than 80 percent and no individual test result is less
than 75 percent. When the running average of three consecutive SE tests falls below 80 percent or an
individual SE test result falls below 75 percent paving operations shall be suspended. The Contractor shall
submit a written plan to correct the low SE test results to the Engineer for approval. The Contractor shall not
continue paving operations until the Engineer approves the plan in writing and three SE test results from
random samples in the stockpile are above 80 percent
Delete subsection 106.06 and replace with the following:
106.06 Sampling and Testing of Portland Cement Concrete Paving. All Portland Cement Concrete
Pavement, Item 412, shall be tested in accordance with the following quality control and acceptance testing
procedures:
(a) Quality Control Testing. The Contractor shall be responsible for quality control testing of all elements listed in
Table 106-3. Quality control testing shall be performed at the expense of the Contractor. The Contractor shall
develop a quality control plan (QCP) in accordance with the following:
1. Quality Control Plan. For each element listed in Table 106-3, the QCP must provide adequate details to
ensure that the Contractor will perform quality control. The Contractor shall submit the QCP to the
Engineer at the preconstruction conference. The Contractor shall not start any work on the project until
the Engineer has approved the QCP in writing.
A. Frequency of Tests or Measurements. The QCP shall indicate a random sampling frequency, which
shall not be less than that shown in Table 106-3. The quality control tests shall be independent of
acceptance tests.
B. Test Result Chart. Each quality control test result, the appropriate area, volume and the tolerance
limits shall be plotted. The chart shall be posted daily at a location convenient for viewing by the
Engineer.
C. Quality Level Chart. The QL for each element in Table 106-3 shall be plotted. The QL will be
calculated in accordance with the procedure in CP 71 for Determining Quality Level. The QL will be
calculated on tests 1 through 3, then tests 1 through 4, then tests 1 through 5, then thereafter the last
five consecutive test results. The area of material represented by the last test result shall correspond
to the QL.
2. Point of Sampling. The material for quality control testing shall be sampled by the Contractor using CP
61. The location where material samples will be taken shall be indicated in the QCP.
3. Testing Standards. The QCP shall indicate which testing standards will be followed. Acceptable
standards are Colorado Procedures, AASHTO and ASTM. The order of precedence is Colorado
Procedures, AASHTO procedures and then ASTM procedures.
April 30, 2009
4
REVISION OF SECTIONS 105 AND 106
CONFORMITY TO THE CONTRACT OF
PORTLAND CEMENT CONCRETE PAVEMENT
(COMPRESSIVE STRENGTH CRITERIA)
The compressive strength test for quality control will be the average strength of two test cylinders cast in
plastic molds from a single sample of concrete, cured under standard laboratory conditions, and tested
three to seven days after molding.
4. Testing Supervisor Qualifications. The person in charge of and responsible for the quality control testing
shall be identified in the QCP. This person shall be present on the project and possess one or more of
the following qualifications:
A. Registration as a Professional Engineer in the State of Colorado.
B. Registration as an Engineer in Training in the State of Colorado with two years of paving experience.
C. A Bachelor of Science in Civil Engineering or Civil Engineering Technology with three years of paving
experience.
D. National Institute for Certification in Engineering (NICET) certification at level III or higher in the
subfields of Transportation Engineering Technology, Highway Materials or Construction Materials
Testing Engineering Technology, Concrete and four years of paving experience.
5. Technician Qualifications. Technicians performing tests shall meet the requirements of Colorado
Procedure 10.
6. Testing Equipment. All of the testing equipment used to conduct quality control testing shall conform to
the standards specified in the test procedures and be in good working order.
7. Reporting and Record Keeping. The Contractor shall report the results of the tests to the Engineer in
writing at least once per day. The Contractor shall assemble a Quality Control (QC) notebook and update
it daily. This notebook shall contain all worksheets, test results forms, test results charts and quality level
charts for each of the elements listed in Table 106-2 or 106-3. The Contractor shall submit examples of
worksheets, test result forms and test results charts in accordance with CP 12B as part of the
Contractor's Quality Control Plan (QCP). The Contractor shall submit the QC notebook to the Engineer
for review once a month on the date agreed to at the Pre -Construction Conference. The QC notebook
will be returned to the Contractor with a list of recognized deficiencies within two working days after
submittal. Deficiencies may include, but are not limited to the failure to submit the notebook on time or an
absence of the required reports. For any month in which deficiencies are identified, the QC notebook will
be submitted for review two weeks after the QC notebook is returned. Upon the second recognized
deficiency the Engineer will notify the Contractor, and the pay estimate shall be withheld until the
Contractor submits, in writing, a report detailing the cause for the recognized deficiency. The report shall
include how the Contractor plans to resolve the deficiencies. Additional recognized deficiencies will result
in a delay of the pay estimate until the Contractor has identified and resolved the deficiency along with
revising and resubmitting his QCP to address these issues. Once the Engineer has reviewed and
approved the revised QCP the estimate may be paid. Upon submittal of the QC notebook for the semi-
final estimate, the QC notebook shall become the property of the Department. The Contractor shall make
provisions such that the Engineer can inspect quality control work in progress, including QC notebook,
sampling, testing, plants, and the Contractor's testing facilities at any time.
(b) Acceptance Testing. Acceptance testing frequencies will be in accordance with Table 106-3. Acceptance
tests will be conducted by and at the expense of the Department. Acceptance sampling and testing
procedures will be in accordance with the Department's Field Materials Manual with the following exceptions
and inclusions:
A split sample from an acceptance test shall not be used for a quality control test. The Engineer will
designate the location where samples are to be taken. Samples shall be taken by the Contractor in
accordance with CP 61. The Engineer will be present during the sampling and take possession of all
acceptance samples. Samples transported in different containers will be combined and mixed before molding
specimens. All materials are subject to inspection and testing at all times.
Pavement thickness acceptance will be determined by cores.
April 30, 2009
5
REVISION OF SECTIONS 105 AND 106
CONFORMITY TO THE CONTRACT OF
PORTLAND CEMENT CONCRETE PAVEMENT
(COMPRESSIVE STRENGTH CRITERIA)
The compressive strength test for acceptance will be the average compressive strength of three test cylinders
cast in plastic molds from a single sample of concrete and cured under standard laboratory conditions prior to
testing. If the compressive strength of any one specimen differs from the average by more than 10 percent,
that specimen will be deleted and the average strength will be determined using the remaining two
specimens. Each set of three cylinders will be tested at 28 days after molding.
(c) Check Testing. The Contractor and the Engineer shall conduct a check testing program (CTP) prior to the
placement of any concrete pavement. The check testing program will include a conference directed by the
Region Materials Engineer of the Contractor's testers and the Department's testers concerning methods,
procedures and equipment for compressive strength testing. Check testing shall be completed before any
portland cement concrete pavement is placed. A set of three cylinders will be molded by both the Contractor
and the Department's project testers from a split sample. The specimens will be sampled, molded and cured
for seven days and tested for compressive strength according to the procedures of Section 106. The
Department's Independent Assurance Tester will also mold, cure and test a set of three cylinders, but the
Independent Assurance Test results will not be entered in the check testing analysis. If the results of the
check tests do not meet the following criteria, then the check testing will be repeated until the following criteria
are met:
1. The average of the Contractor's test results and the average of the Department's test results shall be
within 10 percent of the average of all test results.
2. Each specimen test result shall be within 15 percent of the average of all test results.
A check test must also be conducted on the sand equivalent test. The average of the absolute differences
between the quality control and the acceptance testing personnel will be compared to the acceptable limits
shown in Table 13-1 of CP 13. The CTP will be continued until the acceptance and quality control test results
are within the permissible ranges shown in Table 13-1 of CP 13.
During production, split samples of randomly selected acceptance tests will be compared to the permissible
ranges shown in Table 13-1 of CP 13. The minimum frequency will be as shown in Table 106-3.
If production has been suspended and then resumed, the Engineer may order a CTP between quality control
and acceptance testing persons to assure the test results are within the permissible ranges shown in Table
106-4. Check test results shall not be included in quality control testing. The Region Materials Engineer shall
be called upon to resolve differences if a CTP shows unresolved differences beyond the ranges shown in
Table 13-1 of CP 13.
(d) Testing Schedule. All samples used to determine I/DP by quality level formulas in accordance with
Section 105, will be selected by a stratified random quality.