Loading...
HomeMy WebLinkAbout109260 D P C INDUSTRIES - PURCHASE ORDER - 9950421City of F6rt Collins Page Number: 1 Date: 1 /15/2009 BLANKET Purchase Order Number Delivery Date: 1/15/2009 Buyer: BONNETTE, ED Purchase Order number must appear on invoices, packing lists, labels, bills of lading, and all correspondence. Note: THIS PURCHASE ORDER IS FOR THE PROCUREMENT OF GOODS AND/OR SERVICES, AS NEEDED DURING THE CURRENT CALENDAR YEAR. DOLLAR AMOUNTS SPECIFIED ARE ESTIMATES AND NOT A PROMISE TO PURCHASE ANY MINIMUM AMOUNT OF SUCH GOODS AND/OR SERVICES. Line Qty/Units Description Extended Price 1 BLANKET PO FOR 2009 40,000.00 CHLORINE FOR CHLORINE $520.00/TON IN 2,000 LB. CYLINDERS, F.O.B. FORT COLLINS, COLORADO WATER TREATMENT FACILITY; PER MAPO BID. CHLORINE VENDOR WILL FOLLOW: FCWTF SOP FOR PURCHASING°LIQUID CHLORINE REV 12/31/08, ENCLOSED. PLEASE FORWARD MSDS AND NSF INFO, PER ENCLOSED LETTER. 2 BLANKET PO FOR 2009 4,000.00 SODIUM BISULFITE IN 616 LB. DRUMS @ $0.35/1-B. F.O.B. FORT COLLINS, COLORADO WATER TREATMENT FACILITY. PER JACK WARD QUOTE 1/7/09. 3 BLANKET PO FOR 2009 1,000.00 CHEMICAL SUPPLIES Total $45,000.00 City of Fort CoffinCoffinj Director of Purchasing and Risk Management City of Fort Collins This order is alid over $5000 unless signed by James B. O'Neill II, CPPO Accounting Department City of Fort Collins Purchasing, PO Box 580, Fort Collins, CO 80522-0580 PO Box 580 Phone: 970-221-6775 Fax: 970-221-6707 Email: purchasing@fcgov.com Fort Collins, CO 80522-0580 City of Fort Collins Water Treatment Facility Fort Collins Standard Operating Procedure Services Purchasing Liquid Chlorine Author: Rita DeCourcey Section: Administration Subject: FCWTF SOP for Chlorine Purchases Revision: Rita DeCourcey Revision Date: December 31, 2008 Approvals (SN!natu Voytko, P.E., Water and Dates): / OZil aall._ Chuck Gross, Plant Superintendent 051-09 Manager PURPOSE Establish guidelines for purchasing Liquid Chlorine (Chlorine) for the Fort Collins Water Treatment Facility (FCWTF). The mission of the Fort Collins Water Treatment Facility (FCWTF) is to "provide the community with a continuous ample supply of treated water that is pleasing, wholesome, free from known health risks, and affordable." The FCWTF purchases products by determining best value for the City. Best value is calculated by combining the following four components: (1) the chemical has been tested in the Pilot Plant and/or approved by the Water Treatment Quality Coordinator; (2) the chemical can meet or exceed all FCWTF standards, the AWWA standards, the NSF standards, and any other regulatory agency standards; (3) the supplier can meet all the FCWTF requirements; and (4) the cost is factored in once it has been determined that a supplier can meet items (1), (2), and (3) above. HEALTH AND SAFETY ISSUES For detailed information, please refer to the MSDS 1. Chlorine is primarily highly toxic. Other hazard classes include oxidizer and corrosive. 2. NFPA Hazard Rating includes: • Health=4 • Flammability=0 • Reactivity=1 • Special=Oxidizer Personal Protective Equipment: • SCBA's. Chemical splash proof Safety Goggles. Leather or rubber gloves. Boots, aprons, and chemical suits should be worn when necessary to prevent skin contact. 4. Leaks and Spills: • If a leak occurs, employees and visitors are to follow the Leak Evacuation Plan. 5. Delivery vehicles: • All one -ton cylinders will be delivered on an open -bed truck. 6. Delivery Containers: • Containers will only be allowed on -site if they are in an acceptable condition as specified below. ��xEary Page I K:/Operate/SOP/Chlorie/ChlorinePurchases.cloc P rq FE Vp City of Fort Collins Water Treatment Facility Fort Collins Standard Operating Procedure Services Purchasing Liquid Chlorine INFORMATION FOR THE FORT COLLINS WATER TREATMENT FACILITY (FCWTF) 1. Chlorine is budgeted in account 502-032201-534110. 2. Chlorine is used as a disinfectant in post treatment and in the on -site generation of Chlorine Dioxide. 3. FCWTF requires chlorine to have 99.5 percent purity. 4. FCWTF requires chlorine to be delivered in one -ton cylinders. 5. FCWTF is capable of storing nine one -ton cylinders on site. 6. FCWTF will reject delivery of any cylinders which appear to be leaking, the cylinder integrity is compromised (e.g., bulges in the tank), physical damage to a valve -protective housing, valve - protective -housing lugs and set screws, damaging fusible plugs, or if the gross weight is under 3,425 lbs. (2,000 lbs. of product, cylinder tare weight 1,500 lbs. for a total of 3,500 lbs. Chlorine Institute requires that cylinders be rejected when the tare weight is less than 95 percent of the original tare weight or, 1,425 lbs.) 7. FCWTF will reject any shipments that do not meet its standard in quality or delivery safety. The supplier will pay the rejected shipment's freight. CHLORINE 1. Chlorine must meet the most current American Water Works Association (AWWA) Standard for chlorine. A. Chlorine shall contain no soluble mineral or organic substances in quantities capable of producing deleterious or injurious effects on the health of persons consuming water that has been treated properly with liquid chlorine. B. All Chlorine supplies shall be dry chlorine. Moisture shall not exceed 150 ppm. (0.015 percent), by weight. C. The sum of all heavy metals shall not exceed 30 ppm (0.003 percent) expressed as lead. Lead shall not exceed 10 ppm (0.001 percent) reported as lead. Mercury shall not exceed 1 ppm (0.0001 percent) reported as mercury. Arsenic shall not exceed 3 ppm (0.003 percent) reported as metallic arsenic. D. The total residue shall not exceed 150 ppm (0.015 percent), by weight, in chlorine as packaged in one -ton cylinders. E. Carbon tetrachloride shall not exceed 100 ppm (0.010 percent). F. Trihalomethanes shall not exceed 300 ppm (0.030 percent). 2. Chlorine must meet the most current National Sanitation Foundation (NSF) Standard 60. 3. Chlorine must be 99.5 percent pure as required by the AWWA Standard B301-99, which requires that chlorine be 99.5 percent pure by volume. SUPPLIER 1. Supplier must guarantee Chlorine meets or exceeds the most current AWWA Standard for Liquid Chlorine. 2. Supplier must guarantee Chlorine meets or exceeds the most current NSF Standard 60. 3. Supplier must guarantee Chlorine is 99.5 percent pure. (Note: the AWWA standard requires 99.5 percent purity). 4. Supplier must be able to supply Chlorine in one -ton cylinders. %�NERfy Page t K:/Operate/SOP/Chlorie/ChlorinePnrchases.cloc o-1ln 9I4 `E � City of Fort Collins Water Treatment Facility Fort Collins F6r Collins Standard Operating Procedure Services Purchasing Liquid Chlorine 5. Supplier must be able to supply Chlorine within 24 hours after an order is placed in the event of an emergency. 6. Supplier will ensure the safety of the delivery vehicles and delivery containers. A. Supplier must inspect one -ton cylinders in accordance with the Chlorine Institute pamphlet 1. Any containers that show evidence of leakage, damage, or corrosion should be rejected before the containers are sent to FCWTF. These containers will be rejected and returned to the supplier by FCWTF. B. Cylinders should not be damaged, leaking, have unusual bulges, no physical damage to the valve -protection housing, valve -protective housing lugs and set screws, or damaged fusible plugs. C. Ensure that the gross weight is not under 3,425 lbs. (2,000 lbs. of product, cylinder tare weight 1,500 lbs. for a total of 3,500 lbs. Chlorine Institute requires that cylinders be rejected when the tare weight is less than 95 percent of the original tare weight, or, 1,425 lbs.) D. Delivery vehicles must meet or exceed all current State of Colorado Department of Transportation (CDOT) regulations. 7. Supplier is required to have a method to ensure that tampering has not occurred from the point of origin to FCWTF unloading point. 8. Each year in January, the supplier will mail to FCWTF a new copy of the MSDS sheet and/or the web site location of the most current version. 9. Each year in January, the supplier will mail to FCWTF a copy of the NSF Certification and AWWA conformance letter. 10. The supplier is to supply FCWTF a recent copy of a letter from the U.S. Department of Transportation, Federal Highway Administration, stating the Motor Carrier Safety Rating, for every carrier used to transport the Chlorine on site. 11. Supplier will be responsible for the cost of the shipment if the delivery is rejected and returned because of the chlorine not being 99.8 percent pure, the Certificate of Analysis has not been given to FCWTF, the delivery not made on open -bed trucks, or problems associated with unsafe containers. DELIVERY 1. All chemical suppliers must fax to the FCWTF (970-221-6736) the following information prior to delivery: a) the name of the driver making the delivery b) the numbers of the tractor and trailer transporting the chemical 2. Delivery trucks must park in the designated area on the north side of LaPorte Avenue outside of the entrance gate. Use a cellular phone to call the facility at (970)221-6690 or walk to the entrance kiosk and press the red call button. Please do not block the facility entrance on LaPorte Avenue. All deliveries are checked by FCWTF personnel prior to entry. 3. The receptionist or person answering the telephone must contact the Duty operator. The Duty operator will verify the delivery from the schedule board. The operator or designee will meet the truck outside the gate. a�NERty Page 3 K:/Operate/SOP/Chlorie/ChlorinePurchases.doc Iq E WP City of Fort Collins Water Treatment Facility Fort Collins Standard Operating Procedure Services Purchasing Liquid Chlorine ' 4. FCWTF personnel will verify that the faxed information matches up with the driver and the delivery vehicle arriving at the FCWTF. If the driver's ID or the tractor and trailer numbers do not match, the truck will not be allowed to enter the facility. The Plant Superintendent will be contacted and the delivery may be rejected. 5. FCWTF personnel will visually inspect the vehicle and the one -ton cylinders.. If FCWTF personnel deem the one -ton cylinders unsafe, the shipment will be rejected and returned to the supplier, at the supplier's cost. 6. The security verification, the supplier's quality assurance analysis, and the City's lab analysis will be given to the Water Quality Coordinator in order to identify the load in the event of any problems. 7. Chlorine must be delivered on open -bed truck trailers on Wednesdays only, unless there is an emergency. 8. In the event of an emergency, Chlorine must be delivered within 24 hours after an order is placed. 9. Delivery driver's point of delivery is the loading dock. Under no circumstances will FCWTF employees board the truck. The driver is required to attach the hoist to each tank or disattach the hoist from each tank. 10. Delivery drivers will record the incoming and outgoing tank identification numbers. 11. Delivery drivers are required to chock and unchock their trucks. 12. Delivery drivers should meet with the operator to become familiar with the location of phones, alarms, and emergency showers that are nearest to the off load location. PURCHASING 1. All contracts and purchases will be made in accordance with the City of Fort Collins Purchasing Department (FCPD) Purchasing Procedures. A copy can be obtained through the Purchasing Department. The Purchasing Department will ensure adherence to the FCPD Purchasing Procedures. 2. FCWTF requires that all suppliers submit the names, locations, and phone numbers of three current clients as part of any bidding process. 3. FCWTF requires that all suppliers submit a list of intended delivery agents (motor carrier) and a letter from the U.S. Department of Transportation, Federal Highway Administration, stating the Motor Carrier Safety Rating for the company as part of any bidding process. Each listed motor carrier's rating must be Satisfactory or above to be considered in the bidding process. 4. All price bids will include Super Fund Tax. 5. FCPD representatives are responsible for ensuring that the items noted in this SOP can be met by the supplier before any contract is awarded. 6. The FCWTF and FCPD will establish, at the beginning of each New Year, a Blanket Purchase Order. 7. FCWTF Operations/Process Supervisor or his designee will place delivery orders on that Purchase Order throughout the year. FCWTF must be able to place orders using telephone, fax, or electronic mail. 8. When placing an order, a delivery date will be specified. 9. This SOP can act as the sole -source justification if only one supplier can meet the criteria specified above. �NER7h Page 4 A■`I'//��` K:/Operate/SOP/Chlorie/ChlorinePurchases.tloc P J4fF � January 7, 2009 Dear City of Fort Collins Water Treatment Chemical Vendor, Congratulations on being awarded City of Fort Collins chemical business for the coming year. As part of the requirement for being a selected vendor, the City requests that you forward the following information as soon as possible: MATERIAL SAFETY DATA SHEET (MSDS), and NSF CERTIFICATION Please forward your information via mail to: City of Fort Collins Water Treatment Facility 4316 W LaPorte Avenue Fort Collins, CO 80521 Attn: Rita DeCourcey Or preferably, e-mail your information in pdf (Adobe) format to rdecourcey@fcgov.com. Thank you for supporting the mission of the City of Fort Collins Water Treatment Facility. Sincerely, Ed Bonnette, C.P.M., CPPB Buyer