Loading...
HomeMy WebLinkAbout280216 JOHNSON CONTOLS INC - CONTRACT - AGREEMENT MISC - LIGHTING RETROFIT PROGRAMTHIS AGREEMENT is dated of the 5th day of May 2008 by and between the CITY OF FORT COLLINS, COLORADO, a municipal corporation (hereinafter called OWNER) and Johnson Controls, Inc., a Colorado Corporation (hereinafter called DESIGN/BUILDER). OWNER AND DESIGN/BUILDER, in consideration of the mutual covenants hereinafter set forth, agree as follows: Article 1. WORK 1. 1.01 DESIGN/BUILDER shall complete all Work as specified or indicated in the Owner-Design/Builder Contract Documents, as set forth in Section 12.01. The Work is generally described as follows: design and construction of a City of Fort Collins Lighting and Retrofit Project. Article 2. THE PROJECT 2.01 The Project for which the Work under the Contract Documents may be the whole or only a part is generally described in the Scope of Work consisting of Sixty Three (63) pages and incorporated herein by this reference. Article 3. CONTRACT TIMES 3.01 Days to Achieve Substantial Completion and Final Payment The Work will be substantially completed on October 1, 2008. Final payment shall be made in accordance with paragraph 13.08 of the General Conditions. 3.02 Liquidated Damages A. DESIGN/BUILDER and OWNER recognize that time is of the essence of the Agreement and the OWNER will suffer financial loss if the Work is not completed within the times specified in paragraph 3.01 above, plus any extensions thereof allowed in accordance with Article 11 of the General Conditions. The parties also recognize the delays, expenses and difficulties involved in proving the actual loss suffered by OWNER if the Work is not completed on time. Accordingly, instead of requiring any such proof, OWNER and DESIGN/BUILDER agree that as liquidated damages for delay (but not as a penalty) DESIGN/BUILDER shall pay OWNER Five Hundred Dollars, ($500.00), One Hundred Dollars ($100.00) for each day that expires after the time specified in paragraph 3.01 for Substantial Completion until the Work is substantially complete. SECTION 00410 BOND NUMBER: 6554825 REISSUE PROPOSAL BOND KNOW ALL MEN BY THESE PRESENTS; that we,* the undersigned as Principal, and Safeco Insurance Company of America Safeco Plaza Seattle ** as Surety, are hereby held and firmly bound unto the City of Fort Collins, Colorado, as OWNER, in the sum of $ One Million Fourteen *** for the payment of which, well. and truly to be made, we hereby jointly and severally bind ourselves, successors, and assigns. THE CONDITION of this obligation is such that whereas the Principal has submitted to the City_ of _Fort Collins, Colorado the accompanying ---- ---------- Proposal and hereby made a part hereof to enter into a Construction Agreement for the construction of. the City of Fort Collins Lighting and Retrofit Project. NOW THEREFORE, a) If said Proposal. shall be rejected, or (b) If said Proposal. shall be accepted and the Principal shall execute and deliver a Contract in the form of Contract attached hereto (properly completed in accordance with said Proposal) and shall furnish a BOND for his faithful performance of said Contract, and for payment of all persons performing labor or furnishing materials in connection therewith, and shall in all other respects perform the Agreement created by the acceptance of said Proposal, then this obligation shall be void; otherwise the same shall remain in force and effect, it being expressly understood and agreed that the liability of the Surety for any and all claims hereunder shall, in no event, exceed the penal amount of this obligation as herein stated. The Surety, for value received, hereby stipulates and agrees that the obligations of said Surety and its BOND shall. be in no way impaired or affected by any extension of the time within which the OWNER may accept such. Proposal.; and said Surety does hereby waive notice of any such extension. Surety Companies executing bonds must be authorized to transact business in the State of. Colorado and be accepted by the OWNER. *Johnson Controls, Inc.; 5757 North Green Bay Avenue, Milwaukee, WI 53209 **WA 98185 ***Thousand Four Hundred Thirteen Dollars and 001100 ($1,014,413.00) 7/96 Section 00410 Page I Attachment #1 - City-wide Lighting Scope Facilities Lincoln Center Ludlow Conference 18 18 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, i L&2L IOP LP Facilities Lincoln Center Ludlow Conference 10 10 Install new 26W CF Can (Dimmable & Grid Ceiling) Facilities Lincoln Center Ludlow Conference 2 0 Sensor -Spec CUS1000 Facilities Lincoln Center Kitchen 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps & (112) 4L IOP-LP Facilities Lincoln Center Kitchen 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Facilities Lincoln Center Kitchen 3 3 Replace lamp w/ 16W R30 Screw in CF Facilities Lincoln Center Kitchen 2 2 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28WIamps & (1/2) 2L IOP-LP Facilities Lincoln Center Corridor 32 0 No Retrofit at this time Facilities Lincoln Center Corridor 3 0 No Retrofit at this time Facilities Lincoln Center Corridor 3 0 No Retrofit at this time Facilities Lincoln Center Lower Corridor / RR Lobo 1 0 No Retrofit at this time Facilities Lincoln Center Lower Corridor / RR Lobo 3 0 No Retrofit at this time Facilities Lincoln Center Lower Corridor / RR Lobo 3 3 Replace lamp wl 16W R30 Screw in CF Facilities Lincoln Center Lower Corridor / RR Lobo 11 0 No Retrofit at this time Facilities Lincoln Center Lower Corritlor / RR Lobo 17 0 No Retrofit at this time Facilities Lincoln Center Lower Corridor / RR Lobb 1 0 No Retrofit at this time Facilities Lincoln Center Womens RR 22 22 Retrofilfixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities Lincoln Center Warrens RR 3 3 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Lincoln Center Mens RR 10 10 Retrofitfixture wl (2) F32T8/ADV84VEW/LUALTO 28W lamps & Of2) 4L IOP-LP Facilities Lincoln Center Mims RR 2 2 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Lincoln Center Intimate Gallery 39 0 No Retrofit at this time Facilities Lincoln Center Intimate Gallery 1 0 No Retrofit at this time Facilities Lincoln Center Intimate Gallery 1 0 No Retrofit at this time Facilities Lincoln Center Gallery / Lobby 39 0 No Retrofit at this time Facilities Lincoln Center Gallery Lobby 2 0 No Retrofit at this time Facilities Lincoln Center Gallery Lobby 1 0 No Retrofit at this time Facilities Lincoln Center Main Lobby 8 8 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & (1/4) 4L IOP-LP Facilities Lincoln Center Main Lobby 8 8 Retrofit fixture w/ (1) F25T8/TL841/ALTO&(1/4)4L IOP-LP Facilities Lincoln Center Main Lobby 4 4 Replace lamp w/ 23W R40 Screw in CF Facilities Lincoln Center Main Lobby 3 3 Replace lamp wl 16W R30 Screw in CF Facilities Linwln Center Main Lobby 1 0 No Retrofit at this time Facilities Linwln Center Main Lobby 2 0 No Retrofit at this time Facilities Lincoln Center Main Lobby 9 0 No Retrofit at this time Facilities Lincoln Center Main Lobby 1 0 No Retrofit at this time Facilities Lincoln Center Main Lobby 24 24 Retrofilfixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & (1/2) 4L IOP-LP (Difficult Ins Facilities Lincoln Center Main Lobby 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EWILUALTO 28W lamps & 2L IOP-LP (Difficult Install) Facilities Lincoln Center Main Lobby 1 0 No Retrofit at this time Facilities Lincoln Center Main Lobby 5 5 Replace lamp w/ 23W R40 Screw in CF Facilities Lincoln Center Main Lobby 4 0 No Retrofit at this time Facilities Lincoln Center Box Once 4 4 Retrofit fixture w/ (2) F17T8/TL841ALTO Lamps, 2L IOP-HP Bllst, & 2x2 kit Facilities Lincoln Center Box Office 5 5 Retrofit fixture w/(2)F32T8/AOV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Lincoln Center Box Office 1 0 No Retrofit at this time Facilities Lincoln Center Box Office Storage 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALTO 28W lamps &2L IOP-LP Facilities Lincoln Center Stairs 3 0 No Retrofit at this time Facilities Lincoln Center Upper Lobby 12 12 Replace lamp w/ 16W R30 Screw in CF Facilities Lincoln Center Upperlobby 2 0 No Retrofit at this time Facilities Lincoln Center Upper lobby 14 0 No Retrofit at this time Attachment #1 - City-wide Lighting Scope Facilities Lincoln Center Upper Lobby 2 0 No Retrofit at this time - Facilities Lincoln Center Storage 1 1 Install new 4'1L28T8 Strip- IOPStnd(Photocell) Facilities Lincoln Center Conference 3 3 Retrofit w/ 26W CF Downlight Kit IS" & Dimmable) Facilities Lincoln Center Stairs 3 0 No Retrofit at this time Facilities Lincoln Center Mech Room 1 1 Replace Lamp w/ 23W Screw in CF Facilities Lincoln Center Spot Light Deck 4 0 No Retrofit at this time Facilities Lincoln Center Control Room 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW4L/ALT0 28W lamps, 2L IOP Sind, & 2x4 Refi Facilities Lincoln Center Control Room 3 0 No Retrofit at this time Facilities Lincoln Center Spot Light Deck 4 0 No Retrofit at this time Facilities Lincoln Center Mech Room 1 1 Replace Lamp w/ 23W Screw in CF Facilities Lincoln Center Offices 24 24 Retrofit fixture w/(2)F32T8/ADV841/EW/LVALTO 28Wiamps&2L I0P-LP Facilities Lincoln Center Under stage hall 15 15 Retrofit fixture w/(2)F32T8/ADV841/EW/LVALTO 28W lamps &2L I0P-LP Facilities Lincoln Center Under stage hall 3 0 No Retrofit at this time Facilities Lincoln Center Bulb storage 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALT028Wiamps&2L I0P-LP Facilities Lincoln Center Under stage/lamp storac 6 0 No Retrofit at this time Facilities Lincoln Center Under stage/lamp storac 7 0 No Retrofit at this time Facilities Lincoln Center Under stage/tamp storac 5 0 No Retrofit at this time Facilities Lincoln Center AN Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP-Sind, & 8' Industrial H Facilities Lincoln Center Dressing Room- Ladies 48 0 No Retrofit at this time Facilities Lincoln Center Dressing Room- Ladies 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L ICE LP Facilities Lincoln Center Dressing Room- Ladies 1 0 Sensor Spec CIR-2R Facilities Lincoln Center Dressing Room- RR 1 1 Retrofit fixture w/ (2) F17T8/A841/ALTO Lamps, 2L IOP-Sind Blist. & 2x2 kit Facilities Lincoln Center Dressing Room- RR 2 2 Install new 2' Vanity Fixture w/ (2) F17T8rTL841/ECO lamps- QHE LP Bllst Facilities Lincoln Center Dressing Room- RR 1 1 Replace lamp w/ 13W Screw in CF Facilities Lincoln Center Dressing Room- RR 1 1 Replace lamp wl 16W R30 Screw in CF Facilities Lincoln Center Dressing Room - RR 1 0 Sensor Spec WSUS Facilities Lincoln Center Dressing Room - Mens 6 6 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L ICE LP Facilities Lincoln Center Dressing Room -Mens 52 0 No Retrofit at this time Facilities Lincoln Center Dressing Room -Mens 1 0 Sensor Spec CIR-2R Facilities Lincoln Center Dressing Room- RR 1 1 Retrofit fixture w/ (2) F17T8lR841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities Lincoln Center Dressing Room -RR 2 2 Install new 2'Vanity Fixture w/(2)F17T8/iL841/ECO lamps -QHE LP BIIst Facilities Lincoln Center Dressing Room- RR 1 1 Replace lamp w/ 13W Screw in CF Facilities Lincoln Center Dressing Room- RR 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities Lincoln Center Exterior 3 3 Install new 100W Pulse Start Metal Halide Wall Pack Facilities Lincoln Center Exterior 1 0 No Retrofit at this time Facilities Lincoln Center Exterior 2 2 Install new Flood Fixture w/ (2) 32W CF Lamps Facilities Lincoln Center Exterior 3 0 No Retrofit at this time Facilities Lincoln Center Exterior 2 0 No Retrofit at this time Facilities Lincoln Center Exterior 7 0 No Retrofit at this time Facilities Lincoln Center Exterior 2 0 No Retrofit at this time Facilities Lincoln Center Exterior 5 0 No Retrofit at this time Facilities Lincoln Center Exterior 3 0 No Retrofit at this time Facilities Lincoln Center Exterior 4 0 No Retrofit at this time Facilities Lincoln Center Exterior 10 10 Install new 2L 13W CF Can (Cold Temperature) Facilities Lincoln Center Exterior 2 0 No Retrofit at this time Facilities Lincoln Center Exterior 3 0 No Retrofit at this time Facilities Lincoln Center Vending 1 0 Sensor Spec VEND MISER- Attachment #1 - City-wide Lighting Scope taoup bite Name Area Description Fists Exist Fists Proposed Retrofit Description _-- SensorT Facilities Mulberry Pool Entry Lobby 12 12 Retrofit fixture w/ (2) F32T8/ADV841/EWILUALTO 28W lamps & (1/2) 4L IOP-LP Facilities Mulberry Pool Entry Lobby 1 1 Install new Green LED Exit w/ Battery Back up Facilities Mulberry Pool Entry Lobby 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities Mulberry Pool Entry Lobby 1 0 No Retrofit at this time Facilities Mulberry Pool Elevator 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Mulberry Pool Stairs 2 2 Retrofit fixture W/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Shia, & 2x4 Ran Facilities Mulberry Pool Stairs 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Stnd, 2x4 Bell Facilities Mulberry Pool Mezzanine 12 12 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W(amps, 2L IOP Sind. 2x4 Fell Facilities Mulberry Pool Mezzanine 2 2 Install new Green LED Exit w/ Battery Back up Facilities Mulberry Pool Weight Room 16 16 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Stnd, 2.4 Bell Facilities Mulberry Pool Weight Room 2 0 Sensor Spec CIR Facilities Mulberry Pool Weight Room 2 2 Install new Green LED Exit w/ Battery Back up Facilities Mulberry Pool Weight Room Storage 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Mulberry Pool Equipment 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L IOP-LP Facilities Mulberry Pool Open Office 16 16 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L OF Stnd, 2x4 Bell Facilities Mulberry Pool Conference 207 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Slid. 2x4 Bell Facilities Mulberry Pool Conference 207 1 0 Sensor Spec WSIR Facilities Mulberry Pool Women's RR 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Women'. RR 1 0 No Retrofit at this time Facilities Mulberry Pool Women's RR 1 0 Sensor Spec CUS1000 Facilities Mulberry Pool Janitor 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Men's RR 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Men's RR 1 0 No Retrofit at this time Facilities Mulberry Pool Men's RR 1 0 Sensor Spec CUS1000 Facilities Mulberry Pool Seating 18 18 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (112) 4L IOP-LP (Difficult ins Facilities Mulberry Pool Seating 2 2 Install new Green LED Exit w/ Battery Back up Facilities Mulberry Pool Seating 2 0 No Retrofit at this time Facilities Mulberry Pool Condor 107 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Men's Locker 115 1 1 Replace lamp w/ 16WR30 Screw in CF Facilities Mulberry Pool Men's Locker 115 1 0 No Retrofit at this time Facilities Mulberry Pool Men's Locker 115 16 16 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Men's Locker 115 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Storage 115A 1 1 Retrofit fixture w/ (2) F32TWADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Reception 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Reception 3 3 Replace [amp w/ 16W R30 Screw in CF Facilities Mulberry Pool Life Guards 5 5 Retrofit fixture w/(2)F32T8/AOV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Mulberry Pool Laundry 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities Mulberry Pool Private/Dressing Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Facilities Mulberry Pool Private/Dressing Room 1 0 Sensor Spec CUS1000 Facilities Mulberry Pool Private/Dressing Room 3 0 No Retrofit at this time Facilities Mulberry Pool Life Guard RR 2 0 No Retrofit at this time Facilities Mulberry Pool Life Guard RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Life Guard RR 2 0 No Retrofit at this time Facilities Mulberry Pool Life Guard RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Women's Locker 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities Mulberry Pool Women's Locker 1 0 No Retrofit at this time Facilities Mulberry Pool Women's Locker 16 16 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028WIamps&2L IOP-LP Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Finds Exist Fixts Proposed Retrofit Description Sensor Type Sensor Qty Facilities Mulberry Pool Women's Locker 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/L/ALTO 28W lamps &2L I0P-LP Facilities Mulberry Pool Pool 34 30 8.1- T8 wet location highboy — direct Control Systen 1 Facilities Mulberry Pool Pool 24 24 6-1- TB wet location highboy — indirect Facilities Mulberry Pool Pool 3 3 Install new Green LED Exit w/ Battery Back up Facilities Mulberry Pool Vestibule 2 2 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L I0P-LP Facilities Mulberry Pool Vestibule 1 1 Install new Green LED Exit w/ Battery Back up Facilities Mulberry Pool Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, (112) 4L IOP-Stud, & 8' Indust Facilities Mulberry Pool Chemical 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stud, & 8' Socket Plat Facilities Mulberry Pool Corridor 1 1 Retrofit fixture w/ (2) F32TS/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Pool Mechanical 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Mulberry Pool Pool Mechanical 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP (Difficult Install) Facilities Mulberry Pool Boiler 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Surd, & 8' Industrial H Facilities Mulberry Pool Electrical 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W Iamps & 2L IOP-LP Facilities Mulberry Pool Stairs 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W[amps & 21 IOP-LP Facilities Mulberry Pool Exterior e 0 No Retrofit at this time Facilities Mulberry Pool Exterior 6 0 No Retrofit at this time Facilities Mulberry Pool Exterior 3 0 No Retrofit at this time Facilities Mulberry Pool Entry Lobby 1 0 Sensor Spec VEND MISER- 1 Facilities Pottery Building Glazing roam 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Sind, & 8' Socket Plat Facilities Pottery Building Pottery wheels 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Sind, & 8' Socket Plat Facilities Pottery Building Hall 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Sind, & & Socket Plat Facilities Pottery Building Hall i 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Facilities Pottery Building Hall 4 4 Replace lamp w/ 16W R30 Screw in CF Facilities Pottery Building Hall 1 1 Install New 21 13W CF Drum Fixture Facilities Pottery Building Boiler 2 2 Install New 2L 13W CF Drum Fixture Facilities Pottery Building Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stud, & 8' Socket Plat Facilities Pottery Building Kiln 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stud, & 8' Socket Plat Facilities Pottery Building Rolling area 3 3 Retrofit fixture w/ (2) F32T8/ADV841 IEW/LUALTO 28W lamps, 2L IOP-Stnd, & 8' Socket Plat Facilities Pottery Building Rolling area RR 1 0 No Retrofit at this time Facilities Pottery Building Rolling area RR 1 0 No Retrofit at this time Facilities Pottery Building Rolling area RR 1 0 Sensor Spec WSIR 1 Facilities Pottery Building Stairs i 1 Install New 2L 13W OF Drum Fixture Facilities Pottery Building Upstairs 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Pottery Building Kitchen sinks 1 1 Install new 2L 13W CF Drum Fixture Facilities Pottery Building Storage i 1 Install New 2L 13W CF Drum Fixture Facilities Pottery Building Upperhall 1 1 Install New 2L 13W CF Drum Fixture Facilities Pottery Building Upper rolling press 1 1 Retrofit fixture w/ (2) F32TS/ADV841/EW/I.UALT0 28W lamps, 2L IOP-Shnd. & 8' Socket Plat Facilities Pottery Building Upper work room 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EWILUALTO 28W lamps, 2L IOP-Stud. & 8' Socket Plat Facilities Pottery Building Upper RR 1 1 Install new 2' Vanity Fixture w/ (2) F17TB/7L841/ECO lamps- OHE LP Bllst Facilities Pottery Building Upper office 1 1 Retrofit fixture w/ (2) F32TB/ADVM11EWILUALT0 28W lamps, 2L IOP-Stud. & 8' Socket Plat Facilities Pottery Building Out building 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L OP Stop, & 2x4 Reg Facilities Pottery Building Out building 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP-Shod. & 8' Socket Plat Facilities Pottery Building Out building 1 1 Install new 2L 13W CF Drum Fixture Facilities Pottery Building Out building 3 3 Install new 26W CF Flood Fixture Facilities Pottery Building Exterior 4 0 No Retrofit at this time Facilities Pottery Building Exterior 3 0 No Retrofit at this time Facilities Pottery Building Exterior 2 2 Install new 26W CF Flood Fixture (Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Forts Proposed Retrofit Description Sensor Type Sensor Qty Facilities Recreation Division Entry 1 0 No Retrofit at this time Facilities Recreation Division Reception Area 16 16 Retrofit fixture w/(3)F32T8/ADV841/EW/LUA-TO 28W lamps &3L IOR LP Facilities Recreation Division Reception Area 7 7 Replace lamp w/ 16W R30 Screw in CF Facilities Recreation Division Play Area 1 0 No Retrofit at this time Facilities Recreation Division Play Area 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities Recreation Division Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I OF LP, & 2L IOP LP (Due Facilities Recreation Division Office 1 0 Sensor Spec WSIR-2P 1 Facilities Recreation Division Couidor 2 0 No Retrofit at this time Facilities Recreation Division Office 3 0 No Retrofit at this time Facilities Recreation Division Office 1 0 Sensor -Spec WSIR i Facilities Recreation Division Storage 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3IOP LP Facilities Recreation Division Copy Room 6 6 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALT028W lamps &3L]OR LP Facilities Recreation Division Copy Room 1 0 Sensor Spec CIR i Facilities Recreation Division Hall 14 0 No Retrofit at this time Facilities Recreation Division Hail 2 2 Install new Green LED Exit w/ Battery Back up Facilities Recreation Division Hall 3 3 Replace lamp w/ 16W R30 Screw in CF Facilities Recreation Division Phone 1 1 Retroftfixture w/(3)F32T8/ADV841/EW/LL/ALTO 28WIamps&3L IOR LP Facilities Recreation Division Janitor 1 i Install New 13W CF Drum Fixture Facilities Recreation Division Janitor 1 1 Retrofilfxture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP LP, delamped Facilities Recreation Division RR Women's 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities Recreation Division RR Women'. 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities Recreation Division RR Women's 1 0 No Retrofit at this time Facilities Recreation Division RR Women's 1 0 Sensor Spec WSIR-2P 1 Facilities Recreation Division RR Men's 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L ]OR LP Facilities Recreation Division RR Men's 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities Recreation Division RR Men's 1 0 No Retrofit at this time Facilities Recreation Division RR Men's 1 0 Sensor Spec WSIR-2P 1 Facilities Recreation Division Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities Recreation Division Office 1 0 Sensor Spec WSIR 1 Facilities Recreation Division Breakroom 3 3 Retrofitfxture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L OF LP Facilities Recreation Division Breakroom 1 0 Sensor Spec CIR i Facilities Recreation Division Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4LIOP LP Facilities Recreation Division Conference 8 8 Reirofilfixture w/ (3) F32T8/ADVS41/EW(LUALTO 28W lamps & 3L OF LP Facilities Recreation Division Conference 1 0 Sensor Spec CIR 1 Facilities Recreation Division Open Office 4 4 Replace lamp w/ 16W R30 Screw in CF Facilities Recreation Division Open Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28WIamps, 4L IOP LP Facilities Recreation Division Open Office 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps. 2L IOP Smd, & 2x4 Refl Facilities Recreation Division Office 2 2 Retrofit fixture w/ (3) F32T8/ADVS41/EW/LUALT0 28W lamps & 3L OF LP Facilities Recreation Division Office 1 0 Sensor Spec WSIR 1 Facilities Recreation Division Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sand. & 2x4 Refl Facilities Recreation Division Office 1 1 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Sind, & 2x4 Reg Facilities Recreation Division Interns 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Surd, & 2x4 Refl Facilities Recreation Division Interns 1 0 Sensor Spec CIR 1 Facilities Recreation Division IT Closet 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OR Sunni, & 2x4 Refl Facilities Recreation Division Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OR Sand, & 2x4 Refi Facilities Recreation Division Exterior 3 0 No Retrofit at this time Facilities Recreation Division Exterior 2 0 No Retrofit at this time Attachment #1 - City-wide Lighting Scope Facilities Recreation Division Exterior 1 1 Install New Enertmn 7800L 13W CF AP Facilities Recreation Division Exterior 1 1 Install new 26W CF Flood Fixture Facilities Recreation Division Breakroom 1 0 Sensor Spec VEND MISER - Facilities Senior Center Kitchen 14 14 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L ICE LP Facilities Senior Center Kitchen 1 0 No Retrofit at this time Facilities Senior Center Kitchen 2 2 Install New Enertron 7026L 2L 13W CF WE Facilities Senior Center Kitchen Dry Storage 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps & 31 IOP LP Facilities Senior Center DHW Heater 1 1 Retrofit fixture w/ (3) F32T8/ADV841dEW/WALTO 28W lamps & 3L IOP LP Facilities Senior Center Multipurpose 3 0 No Retrofit at this time Facilities Senior Center Multipurpose 38 38 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Multipurpose 2 0 Sensor Spec CIR-HIGH Facilities Senior Center Multipurpose 2 0 No Retrofit at this time Facilities Senior Center Multipurpose 3 0 No Retrofit at this time Facilities Senior Center Multipurpose 38 38 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Multipurpose 2 0 Sensor Spec WCDT1500-DI Facilities Senior Center Multipurpose Storage 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALTO 28Wiamps&2L IOP-LP Facilities Senior Center Multipurpose 3 0 No Retrofit at this time Facilities Senior Center Multipurpose 33 33 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Multipurpose 2 0 Sensor Spec CIR-HIGH Facilities Senior Center Multipurpose 1 0 No Retrofit at this time Facilities Senior Center Multipurpose 2 0 No Retrofit at this time Facilities Senior Center Multipurpose Storage 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Senior Center Stage 9 9 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L ICE LP Facilities Senior Center Stage 8 0 No Retrofit at this time Facilities Senior Center Stage 1 0 Sensor Spec CIR-2R Facilities Senior Center Stage 4 0 No Retrofit at this time Facilities Senior Center Stage Storage 1 1 Retrofit fixture w/(3)F32T8/ADV84VEW/LUALTO 28W lamps &3L ICE LP Facilities Senior Center Wet Crafts 9 9 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L ICE LP Facilities Senior Center Wet Crafts 1 0 Sensor Spec CIR Facilities Senior Center Storage 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 31. IOP LP Facilities Senior Center Kiln 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Facilities Senior Center Studio 19 19 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities Senior Center Studio 1 0 Sensor Spec CDT2000 Facilities Senior Center Studio 1 0 No Retrofit at this time Facilities Senior Center Studio Storage 1 1 Rerofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps & 3L POP LP Facilities Senior Center Studio Storage 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps & 3L [OR LP Facilities Senior Center Office 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps & 3L [OR LP Facilities Senior Center Transformer 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Senior Center Men's RR 8 0 No Retrofit at this time Facilities Senior Center Men's RR 7 7 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Women's RR 12 12 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Senior Center Women's RR 8 0 No Retrofit at this time Facilities Senior Center Laundry 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Laundry 1 0 Sensor Spec WSIR Facilities Senior Center Meeting Room 8 0 No Retrofit at this time Facilities Senior Center Meeting Room 1 0 Sensor Spec CIR Facilities Senior Center Meeting Room 8 0 No Retrofit at this time Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Finds Exist Fixts Proposed Retrofit Description Sensor Type Sensor Dty Facilities Senior Center Meeting Room 1 0 Sensor Spec CIR i Facilities Senior Center Billiards 16 0 No Retrofit at this time Facilities Senior Center Billiards 5 5 Retro0l fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities Senior Carle, Billiards 2 0 Sensor Spec WCDT1500 2 Facilities Senior Center Billiards 1 0 No Retrofit at this time Facilities Senior Center Halls 21 0 No Retrofit at this time Facilities Senior Center Halls 5 0 No Retrofit at this time Facilities Senior Center Halls 13 0 No Retrofit at this time Facilities Senior Center Halls 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities Senior Center Lobby/Atrium 36 36 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Senior Center Lobby/Atrium 1 0 No Retrofit at this time Facilities Senior Center Lobby/Atrium 3 0 No Retrofit at this time Facilities Senior Center Lobby/Atrium 5 5 Replace lamp w/32W Screw in CF Facilities Senior Center Reception Area 27 0 No Retrofit at this time Facilities Senior Center Reception Area 9 9 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Facilities Senior Center Reception Area 2 0 No Retrofit at this time Facilities Senior Center Once 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps. I IOP LP, & 2L IOP LP (Due Facilities Senior Center Office 1 0 Sensor Spec WSIR,2P 1 Facilities Senior Center Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps. I IOP LP, & 2L IOP LP (Due Facilities Senior Center Office 1 0 Sensor Spec WSIR-2P 1 Facilities Senior Center Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps, I IOP LP, & 2L IOP LP (Due Facilities Senior Center Office 1 0 Sensor Spec WSIR-2P 1 Facilities Senior Center Open Office 8 8 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps. IL IOP LP, & 2L IOP LP (Due Facilities Senior Center Hall 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I IOP LP, & 2L IOP LP (Due Facilities Senior Center Hall 1 0 No Retrofit at this time Facilities Senior Center Break/Copy 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Facilities Senior Center Conference 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps, 1L IOP LP, & 2L POP LP (Dua Facilities Senior Center Conference 1 0 Sensor Spec WSIR-2P 1 Facilities Senior Center Storage 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L I0P LP Facilities Senior Center Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps, I IOP LP, & 2L POP LP (Dua Facilities Senior Center Office 1 0 Sensor Spec WSIR-2P i Facilities Senior Center Work Room 4 4 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, IL IOP LP, &2L I0P LP (Dua Facilities Senior Center Elevator 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Facilities Senior Center Library 15 15 Retrofit fixture w/(3)F32T8/ADV841/EW/LL/ALT028W lamps &3L I0P LP Facilities Senior Center Library 1 0 Sensor Spec WCDT1500 1 Facilities Senior Center Library 1 0 No Retrofit at this time Facilities Senior Center Lower Hail 8 0 No Retrofit at this time Facilities Senior Center Lower Hall 1 0 No Retrofit at this time Facilities Senior Center Elevator Mach 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W tamps &2L I0P-LP Facilities Senior Center Emergency Stairs 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALT028W lamps &2L I0P-LP Facilities Senior Center Emergency Stairs 1 0 No Retrofit at this time Facilities Senior Center Men's Locker 3 0 No Retrofit at this time Facilities Senior Center Men's Locker 1 0 No Retrofit at this time Facilities Senior Center Men's Locker 8 e Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities Senior Center Men's Locker 15 15 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities Senior Center Men's Locker 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L POP -LP Facilities Senior Center Women's Locker 3 0 No Retrofit at this time Attachment #1 - City-wide Lighting Scope Group rote Name Area Description Fixts Exist Fixts Proposed Retrofit Description Sensor Type Facilities Senior Center Women's Locker 1 0 No Retrofit at this time Facilities Senior Center Women's Locker 8 8 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Women's Locker 15 15 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Women'a Locker 6 6 Retrofit fixture w/(2)F32T8/ADV841/EW/WALTO 28W lamps &2L IOP-UP Facilities Senior Center Hot Tub 4 0 No Retrofit at this time Facilities Senior Center Pool 2 0 No Retrofit at this time Facilities Senior Center Pool 12 12 Retrofit w/ 320W Pulse Start Metal Halide Lamp & Ballast Facilities Senior Center Pool 12 12 Retrofit w/ 320W Pulse Start Metal Halide Lamp & Ballast Facilities Senior Center Pool 2 0 No Retrofit at this time Facilities Senior Center Assisted Changing 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/DUALTO 28W lamps & 2L IOP-LP Facilities Senior Center Assisted Changing 1 0 Sensor Spec MIR Facilities Senior Center Pool Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L OP LP Facilities Senior Center Pool Office 1 0 Sensor Spec WSIR Facilities Senior Center Pool Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/ILALTO 28W lamps & 2L IOP-LP Facilities Senior Center Gym 12 12 Install new 61-32T8 Highbay, w/Dense&Wreguard- IOP-HP Facilities Senior Center Gym 4 4 Remove (1) 1000W MH & Install (2) New 81.32T8 Highbays with Lense & Wireguard - IOP-HF Facilities Senior Center Gym 14 14 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Gym 3 0 No Retrofit at this time Facilities Senior Center Computer 1 1 Retrofit fixture w/(2)F32T8/AOV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Gym Storage 6 6 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Stair 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Senior Center Stair 1 0 No Retrofit at this time Facilities Senior Center Pool Chemical 6 6 Retrofitfixture w/(2)F32T8/ADV841/EW/LUALTO 28Wiamps&2L OR -LP Facilities Senior Center Chemical Storage 1 1 Install New Enertron 7026L 21. 13W OF WP Facilities Senior Center Chemical Storage 1 1 Install New Enertron 7026L 21 13W OF WV Facilities Senior Center Pool Boilers 10 10 Retrofitfixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L [OP -LP Facilities Senior Center Electrical 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Senior Center Upper Lobby/Exercise 6 6 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L OP LP Facilities Senior Center Upper Lobby / Exercise 1 0 No Retrofit at this time Facilities Senior Center Activity Rm 3 11 0 No Retrofit at this time Facilities Senior Center Activity Rm 3 1 0 Sensor Spec CIR Facilities Senior Center Activity Run 3 Storage 1 i Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities Senior Center Track 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Senior Center Exterior 13 0 No Retrofit at this time Facilities Senior Center Exterior 14 0 No Retrofit at this time Facilities Senior Center Exterior 13 0 No Retrofit at this time Facilities Senior Center Exterior 2 0 No Retrofit at this time Facilities Senior Center Exterior 22 0 No Retrofit at this time Facilities Senior Center Exterior 1 0 No Retrofit at this time Facilities Senior Center Halls Vending 1 0 Sensor Spec VEND MISER - Facilities Streets Adminislrativ Entry 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28Wlamps&2L IOP-LP Facilities Streets Administrati, Reception 20 0 No Retrofit at this time Facilities Streets Administrati, Reception 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Streets Administrati, Reception 14 14 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Streets Administrati, Reception i 1 Install new Green LED Exit w/ Battery Back up Facilities Streets Administrain, Reception 6 6 Install new 26W OF Track fixture Facilities Streets Administrati, Office 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fills Exist Fixs Proposed Retrofit Description Sensor Type Sensor Qty Facilities Streets Administrati, Office t 0 Sensor Spec W51R 1 Facilities Streets Administratio File/Office 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Streets Administrati, File/Office 1 0 Sensor Spec WSIR 1 Facilities Streets Administrati. Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841 /EW/LUALTO 28W lamps &2L I0P-LP Facilities Streets Administrati, Office 1 0 Sensor Spec WSIR i Facilities Streets Administrati, Office 4 4 Retrofit fixture w/(2)F32T8/AOV841/EW/LL/ALT028W lamps &2L I0P-LP Facilities Streets Administrati, Office 1 0 Sensor Spec WSIR t Facilities Streets Administrati, Computer 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALT028W lamps &3L I0P LP Facilities Streets Administrati, Office 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L I0P-LP Facilities Streets Administrati Office 1 0 Sensor Spec WSIR t Facilities Streets Administrati, Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Streets Administrab Office 1 0 Sensor Spec WSIR 1 Facilities Streets Admiristratii Office 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Facilities Streets Administrati-Office 1 0 Sensor Spec WSIR 1 Facilities Streets Administrati, Office 4 4 Retrofit fixture w/(2)F32T8/ADV84VEW/WALTO 28W lamps &2L I0P-1-P Facilities Streets Admiri Office 1 0 Sensor Spec WSIR i Facilities Streets Administrativ Hall 14 0 No Retrofit at this time Facilities Streets Administrati, Hail 1 1 Install new Green LED Exit w/ Battery Back up Facilities Streets Administrati, Hall 1 0 No Retrofit at this time Facilities Streets Administrati� Open Office 8 8 Retrofit fixture w/(2)F32T8/ADV84t/EW/LUALTO 28W lamps &2L I0P-LP Facilities Streets Administrati, Open Office 1 0 Sensor Spec CDT1500 1 Facilities Streets Administrati, RR 1 1 Retrofit fixture w/(1)F32T8/ADV84t/EW/LUALT028W lamps &IL I0P-LP Facilities Streets Administrab RR 3 0 No Retrofit at this time Facilities Streets Administrati, RR 1 0 Sensor Spec WSUS 1 Facilities Streets Administrati-RR t t Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps &IL IOP-LP Facilities Streets Administrati, RR 3 0 No Retrofit at this time Facilities Streets Administrativ RR 1 0 Sensor Spec WSUS 1 Facilities Streets Administrati, Break room 6 6 Retrofit fixture w/(2)F32T8/ADV84t/EW/LUALTO 28W lamps &2L IOP-LP Facilities Streets Administrati, Conference 6 6 New 26W Can- Dimmable (grid ceiling) Facilities Streets Administrativ Conference 14 14 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Facilities Streets Administrativ Conference 1 0 Sensor Spec WCDT1500 1 Facilities Streets Adminicratii Janitor 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LL/ALTO 28W [amps &3L I0P LP Facilities Streets Administrati, Electrical 1 1 Retrofit fixture wl (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L On LP Facilities Streets Administrati, Crew Room 6 6 Retrofit fixture wl (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L IOP LP Facilities Streets Administrativ Crew Office 3 3 Retrofit fixture wl (2) F32T8IADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Streets Administati, Crew Office 1 0 Sensor Spec CIR-HIGH 1 Facilities Streets Administraf, Crew Room 10 10 Retrofit fixture w/ (3) F32T8/ADV841/EWILUALTO 28W lamps & 3L IOP LP Facilities Streets Administra5 Crew Once 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities Streets Administrati, Crew Office 1 0 Sensor Spec WSIR 1 Facilities Streets Administrati, Crew Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Facilities Streets Administrate, Crew Office 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Facilities Streets Administrati, Crew Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L I0P-LP Facilities Streets Administratir Crew Office 1 0 Sensor Spec WSIR 1 Facilities Streets Administrati, Corridor 22 0 No Retrofit at this time Facilities Streets Administrati, Corritlor 1 1 Install new Green LED Exit w/ Battery Back up Facilities Streets Administrati, Corridor 1 0 No Retrofit at this time Facilities Streets Administrati, Mans Locker 4 4 Retrofit fixture wl (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP (Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fiats Exist Fiats Proposed Retrofit Description Sensor Type Sensor Qty Facilities Streets Adminisnati- Mans Locker 6 6 Retrofit fixture w/ (2) F17T8/fL841/ALTO Lamps, 2L IOP-Stnd Bllst, & 2x2 Refl Kit Facilities Streets Administrati, Mans Locker 1 1 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps &1L IOP-LP Facilities Streets Administratt, Mans Locker 1 0 Sensor Spec CUS2000 1 Facilities Streets Administraty Men. Locker 2 0 No Retrofit at this time Facilities Streets Administrati, Mud Room 3 3 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Facilities Streets Administrativ Mud Room 1 0 Sensor Spec CIR 1 Facilities Streets Administrati, Women's Locker 5 5 Retrofit fixture w/ (2) F17T8/fL841/ALTO Lamps, 2L IOP-Sand Sllst, & 2x2 Refl Kit Facilities Streets Administrati,Women's Locker 1 1 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALT028W lamps &1L IOP-LP Facilities Streets Administrafiv Women's Locker 1 0 Sensor Spec CUS2000 1 Facilities Streets Administrati, Women's Locker 2 0 No Retrofit at this time Facilities Streets Adminislrativ Storage 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps, 2L IOP-Smd, & 8'Industrial H Facilities Streets Admirinnrati� Mach Equipment 5 5 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L IOP-LP Facilities Streets Administrati, Mach Equipment 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps & (1 /2) 4L IOP-LP Facilities Streets Administrativ Boiler Room 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L IOP-LP Facilities Streets Administrati,Training Room 17 17 Retrofit fixture w/ (3) F32T8/ADV841 /EW/LUALT0 28W lamps &3L IOP LP Facilities Streets Administrati,Training Room 3 3 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stud ells(, & 2x2 Roll Kit Facilities Streets AdministrativTraining Room 1 0 No Retrofit at this time Facilities Streets Administrativ Training Room 14 14 New 26W Can- Dimmable (grid ceiling) Facilities Streets Administrativ Kitchen / Vending 4 4 Retrofit fixture wl (2) F17T8rU 841/ALTO Lamps, 2L IOP-Stnd Ean, & 2x2 Refl Kit Facilities Streets Administrati, Storage 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALT028W lamps &3L IOP LP Facilities Streets Administratii Wellness 8 8 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities Streets Administrati, Wellness 1 0 Sensor Spec CIR-HIGH i Facilities Streets Administrativ Crew Area 6 6 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I IOF LP. & 2L 10P LP (Due Facilities Streets Administrati, Crew Area 1 0 Sensor Spec WSIR-2P 1 Facilities Streets Administrati, Once 3 3 Retrofit fixture w/(2)F32T6/ADV841/EW/LUALT028W lamps &2L IOP-LP Facilities Streets Administrati, Office 1 0 Sensor Spec WSIR i Facilities Streets Administrativ Computer Area 8 8 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I IOP LP, & 2L IOP LP (Dua Facilities Streets Adminislrafiv Computer Area 1 0 Sensor Spec CDT1500-HIGi 1 Facilities Streets Administrati, Work Shop 13 13 Retrofit fixture wl (4) F32T8/ADV841/EW/LUALTO 28W lamps, 41-IOP-LP, & V Industral Ho Facilities Streets Administrati,Work Shop 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps&3L IOP LP Facilities Streets Admininrefir Phone Room 1 1 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALT028W lamps, 4LIOP-LP,&8'Industnal Ho Facilities Streets Administrati, Storage 2 2 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALT028Wiamps. 4L1OP-LP,&S'Induslrial Ho Facilities Streets Administrafi� Sign Fabrication 12 12 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities Streets Adminislrati� Warehouse Area 4 4 Retrofit fixture w/(1)F32T8/ADV84VEW/WALT028W lamps&1L IOP-LP Facilities Streets Admini.trativ Warehouse Area 64 64 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, (1/2) 4L IOP-LP. 8'2L lndustn Facilities Streets Administrati, Warehouse Area 2 2 Install new Green LED Exit w/ Battery Back up Facilities Streets Administrati,Women's RR 2 0 No Retrofit at this time Facilities Streets Admini.trafir Women's RR 1 1 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps &1L IOP-LP Facilities Streets Adminislrati� Women's RR 1 0 Sensor Spec WSIR i Facilities Streets Administrati, Men's RR 1 1 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W tamps &1L IOP-LP Facilities Streets Administrati, Men's RR 2 0 No Retrofit at this time Facilities Streets Administrati, Men's RR 1 0 Sensor Spec WSIR 1 Facilities Streets Adminitund, Truck Bays 20 20 Install new 8'61-T81ndustrial fixture - IOP-HP Facilities Streets Administrati, Truck Bays 3 3 Install new Green LED Exit w/ Battery Back up Facilities Streets Administratii Upper Storage 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, (1/2) 4L IOP-LP, 8' 2L Industn Facilities Streets Administrati, Upper Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-LP, 8' 2L Industrial He Facilites Streets Administrati, Parts Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP-LP, 8' 2L Industrial He IN WITNESS WHEREOF, the Principal and the Surety have hereunto set their hands and seals this 12th day of May , 2008, and such of them as are corporations have caused their corporate seals to be hereto affixed and these presents to be signed by their proper officers, the day and year first set forth above. PRINCIPAL SURETY Name: Johnson Controls, Inc. Safeco Insurance Company of America Address: 5757 North Green Bav Avenue Milwaukee, VI53209 By: Catherine B. Hutson Title: Attorney -In -Fact Safeco Plaza Seattle, WA 98185 By: i�%y A� elP Trac K Matthev�s_ Title: Attorney -In -Fact ATTEST: By:� (SEAL) 7/96 Section 00410 Page 2 (SEAL) Attachment #1 - Citv-wide Liahtina SCODe Group Site Name Area Description Finds Exist Fuds Proposed Retrofit Description - - - Sensor Type Sensor city Facilities Streets Administrati-Parts Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-LP, 8' 2L Industrial He Facilities Streets Administrati, Parts Storage 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, (1/2) 4L IOP-LP, 8' Socket Ple Facilities Streets Administratii Parts Storage 1 1 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & (1/3) 3L IOP-LP Facilities Streets Administrati, Parts Storage Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps. 2L IOP Sea, & 2x4 Refl Facilities Streets Administrati, Oil Storage 3 3 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps, 2L IOP-Sind,&8'Industrial H Facilities Streets AdministrativVehicle Storage 13 13 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Streets Administrati, Vehicle Storage 2 2 Install new Green LED Exit w/ Battery Back up Facilities Streets AdministratiWehicle Storage 1 0 No Retrofit at this time Facilities Streets Administrati Vehicle Storage 39 39 Retrofit fixture w/ (2) F32TB/ADV841/EW/LUALTO 28W lamps, 2L IOP-Sand, & 8' Industrial H Facilities Streets Administrati, Vehicle Wash 16 16 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP Sind, & 8' Socket Plat Facilities Streets Administrati, Street Sweeper 20 20 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP Said, & 8' Industrial H Facilities Streets Administrati, Street Sweeper Storage 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L OR Said, & 8' Industrial H Facilities Streets Administrati, Fuel Storage 2 0 No Retrofit at this time Facilities Streets Administrati, Fuel Storage 12 0 No Retrofit at this time Facilities Streets Administralir Fuel Storage 12 0 No Retrofit at this time Facilities Streets Administrate, Fuel Storage 1 0 No Retrofit at this time Facilities Streets Administrati, Soffit Cans 4 0 No Retrofit at this time Facilities Streets Administrati, Large MH Flood 3 0 No Retrofit at this time Facilities Streets Administrab Garage Entry 9 0 No Retrofit at this time Facilities Streets Administimb Large pole lights high 9 0 No Retrofit at this time Facilities Streets Administrati, Large Poles Brown 3 0 No Retrofit at this time Facilities Streets Administrati, Smaller Poles Brown 11 0 No Retrofit at this time Facilities Streets Administrati- Exterior 9 0 No Retrofit at this time Facilities Streets Administrati, Exterior 5 0 No Retrofit at this time Facilities Streets Administnativ Exterior 12 0 No Retrofit at this time Facilities Streets Administrati, Training Roam 1 0 Sensor Spec VEND MISER- 1 Facilities Streets Adminatrati, Kitchen/Vending 1 0 Sensor Spec VEND MISER- 1 Facilities Transfort Administr Atlmin Entry 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28WIamps&2L IOP-LP Facilities Transfort Administrz Atlmin Hall 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028WIamps&(1/2)4L IOP-LP Facilities Transfort Administr Admin Hall 2 2 Retrofit fixture w/ (2) F25T8/R841/ALTO Lamps &(1/2)4L IOP-LP Blist Facilities Transfort Administr Condor 12 0 No Retrofit at this time Facilities Transfort Administre C0md0r 3 0 No Retrofit at Reis time Facilities Transfort Administre Office 6 6 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &(1/2)4L IOP-LP Facilities Transfort Administr Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Transfort Administrz Office 1 1 Retrofit fixture w/ (2) F 1 7T8,71841/ALTO Lamps, 2L IOP-Sand Bllst,&2x2 kit Facilities Transfort Administr Conference 8 0 No Retrofit at this time Facilities Transfort Administrz Conference 3 0 No Retrofit at this time Facilities Transfort Administre Conference 2 2 Replace lamp w/ 16W R30 Screw in CF Facilities Transfort Administr Conference 1 0 Sensor Spec CUR 1 Facilities Transfort Administr Dispatch 8 0 No Retrofit at this time Facilities Transfort Administrz Dispatch 2 4 0 No Retrofit at this time Facilities Transfort Administrz Dispatch 3 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps& 2L ]OR Sind(Delamped) Facilities Transfort Administr Electrical/Supply 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALTO 28W lamps &2L IOP-LP Facilities Transfort Administrz Electrical/Supply 1 0 Sensor Spec WSIR i Facilities Transfort Administrz Computer 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALTO 28W lamps &2L IOP-LP Facilities Transfort Administrz Computer 2 2 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28W lamps, 4L I OR LP Facilities Transfort Administrz Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOR LP Attachment #1 - City-wide Lighting Scope Facilities Transfort Administr Office 1 0 Sensor Spec WSIR Facilities Transfort Administrz Corridor 1 1 Retrofit fixture w/ (2) F32T8IADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Transfort Administre Storage/Electrical 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps & (1 /2) 4L IOP-LP Facilities Transfort Administr Mans RR 1 i Retrofit fixture w/ (2) F17T8/fLe41/ALTO Lamps, 2L IOP-Stnd Bllst, & 2x2 kit Facilities Transfort Administre Mans RR 1 i Retrofit fixture w/ (2) F25T8frL841/ALTO Lamps, IOP-Stud Bllst. 6' 2L Conversion Kit (Cove) Facilities Transfort Administrz Mans RR 2 2 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps, (1/2) 2L IOP-Stnd (Delamped Facilities Transfort Admidstr<Mans RR 1 1 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps. 1L IOP-Sind, & 4' Centering K Facilities Transfort Administrz Mena RR 1 0 Sensor Spec WSUS Facilities Transfort Administrz Mena RR 1 i Replace lamp w/ 13W Screw in CF Facilities Transfort Administrz Womens RR 1 1 Retrofit fixture w/ (2) F17T81R841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities Transfort Administrz Wearers RR 2 2 Retrofit fixture w/(1)F32T8/ADV841/EWTUALTO 28W lamps. (1/2) 2L IOP-Slnd(Delamped; Facilities Transfort Administrz Warrens RR 2 2 Retrofit fixture w/(1)F32T8/ADV841/EW/WALTO 28W lamps, I IOP-Stnd,&4'CenteringK Facilities Transfort Administrz Womens RR 1 0 Sense, Spec WSUS Facilities Transfort Administrz Womens RR 1 1 Replace lamp w/ 13W Screw in CF Facilities Transfort Administrz Conference 16 16 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps&(1/2)4L IOP-LP Facilities Transfort Administrz Conference 2 2 Retrofit fixture w/(2) F25TBITL841/ALTO Lamps &2L IOP-LP Sllst Facilities Transfort Administrz Office 2 2 Retrofit fixture w/(3)F32TB/ADV841/EW/LUALTO 28W lamps &3L IOP LP Facilities Transfort Administrz Office 1 0 Sensor Spec WSIR Facilities Transfort Administr Storage 1 1 Retrofit fixture w/(3)F32T6/ADV841/EW/LUALTO 28W lamps &3L IOP LP Facilities Transfort Administrz Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W[amps &3L IOP LP Facilities Transfort Administrz Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Facilities Transfort Administrz Ofg 1 0 Sensor Spec WSIR Facilities Transfort Administrz Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EWTUALTO 28W lamps &3L IOP LP Facilities Transfort AdministrE Office 1 0 Sensor Spec MIR Facilities Transfort Administrz Garage West 15 0 No Retrofit at this time Facilities Transfort Administrz Garage West 1 1 Install new 8' 6LT8 Vapor Tight Fixture- IOP-HP (850K) Facilities Transfort Administrz Garage West 1 1 Install new Green LED Exit Facilities Transfort Administr Garage North 5 0 No Retrofit at this time Facilities Transfort Administrz Garage North 14 14 Install new 8' 6LT8 Vapor Tight Fixture - IOP-HP (850K) Facilities Transfort Administr Garage North 1 1 Install new 8' 6L28T8 Vapor Tight Fixture- IOP-HP (850K) Facilities Transfort Administr Garage North 1 1 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & I IOP-LP Facilities Transfort Administrz Garage East 16 0 No Retrofit at this time Facilities Transfort Administrz Garage East 4 4 Install new Green LED Exit Facilities Transfort Administrz Garage South 15 15 Install new 8' 6LT8 Vapor Tight Fixture- IOP-HP (850K) Facilities Transfort Administrz Garage South 10 10 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Transfort Administrz Garage South 1 1 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps &iL IOP-LP Facilities Transfort Administr Storage 1 t Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Transfort Administrz Electrical 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP (20' High) Facilities Transfort Administrz Garage South.l 16 16 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALTO 28W lamps & (112) 4L IOP-LP (20' High) Facilities Transfort Administre Garage South.2 8 8 Retrofit fixture w/(2)F32T8/ADV841/EWTUALTO 28W lamps & (1/2) 4L IOP-LP (20' High) Facilities Transfort Administrz Garage South.3 2 2 Install new 8'6LT8 Vapor Tight Future-IOP-HP(850K) Facilities Transfort Administre Garage South.3 6 6 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28W lamps, 4L OR Sind, & (RU-VP??) Facilities Transfort Administr Garage South.3 1 0 No Retrofit at this time Facilities Transfort Administrz Garage South.4 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (112) 4L IOP-LP (20' High) Facilities Transfort Administrz Storage 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps & (112) 4L IOP-LP Facilities Transfort Administr Compressor 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps & (1 /2) 4L IOP-LP Facilities Transfort Administrz Garage Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W tamps, 2L [OR Sind, &delamped Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Finds Proposed Retrofit Description Sensor Type Sensor Qty Facilities Transfort Administrz Corridor 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21. ]OR Sintl, & tlelamped Facilities Transfort Administrz Office VCT 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & tlelamped Facilities Transfort Administr Office VCT 1 0 Sensor Spec WSIR 1 Facilities Transfort Adminislre Office VCT 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OR Sind, & tlelamped Facilities Transfort Administrz Office VCT 1 0 Sensor Spec WSIR 1 Facilities Transfort Administrz Lunch Room 3 3 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps, 2L ]OR Sind, &delamped Facilities Transfort Administr Lunch Room 1 0 Sensor -Spec WSIR 1 Facilities Transfort Administrz Womens RR 2 2 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps, (1/2) 2L IOP-Sintl (Delamped Facilities Transfort Administrz Womens RR 2 2 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps, I IOP-Stnd, & 4' Centering V Facilities Transfort Administrz Womens RR 1 1 Retrofit fixture w/ (2) F25T8frL841/ALTO Lamps, IOP-Sind Blist, 6' 2L Conversion Kit (Cove) Facilities Transfort Administrz Womens RR 1 1 Install New 13W CF Drum Fixture Facilities Transfort Administrz Womens RR 1 0 Sensor Spec WSUS 1 Facilities Transfort Administrz Janitor 1 1 Install New 13W CF Drum Fixture Facilities Transfort Administrz Mans RR 2 2 Retrofit fixture w/(1)F32T8/ADV84VEW/LUALTO 28W lamps, (112) 2L IOP-Stnd(Delamped, Facilities Transfort Adminislre Mans RR 1 1 Retrofit fixture w/(1)F32T8/ADV841/E)A/LUALTO 28W lamps, i L IOP-Sind,&4'Cemeringk Facilities Transfort Administrz Mans RR 1 1 Retrofit fixture w/ (2) F25T8/TL841/ALTO Lamps, IOP-Sind Blist, 6' 2L Conversion Kit (Cove) Facilities Transfort Administrz Mons RR 1 0 Sensor Spec WSUS 1 Fadlities Transfort Administrz Mens Shower 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Transfort Administrz Mena Shower 1 1 Replace lamp w/ 13W Screw in CF Facilities Transfort Administrz Mans Shower 1 0 Sensor Spec WSIR 1 Facilities Transfort Administrz Equipment Storage 8 8 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps & (1/4) 4L IOP-LP Facilities Transfort Administrz Equipment Storage 4 4 Retrofit fixture w/(1)F32T8/ADV84VEW/LUALTO 28W lamps & (1/2) 2L IOP-LP Facilities Transfort Administrz Parts Storage 32 32 Retrofit fixture w/(i)F32T8/ADV84VEW/LUALTO 28W lamps & (1/4) 4L IOP-LP Facilities Transfort Administr Parts Storage 20 20 Retrofit fixture w/(1)F32T8/ADV84VEW/LUALTO 28W lamps & (112) 2L IOP-LP Facilities Transfort Adminislre Parts Storage 9 9 Retrofit fixture w/(1)F32T8/ADV84VEW/-UALTO 28W lamps &1L IOP-LP Facilities Transfort Administr Paris Storage 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Facilities Transfort Administrz Upper Mechanical Room 14 14 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities Transfort Administrz Bus Wash Storage 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP (20' High) Facilities Transfort Administrz Bus Wash Bay 4 4 Install new 8'4128T8 Vapor Tight Fixture - IOP-HP Facilities Transfort Administrz Bus Wash Bay 2 0 Sensor Spec CIR-HIGH-VVE 2 Facilities Transfort Administrz Bus Wash Bay 1 i Install new Green LED Exit Facilities Transfort Administrz Bus Wash Storage 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & (112) 4L IOP-LP (20' High) Facilities Transfort Administrz Money Entry 2 2 Retrofit w/ 18W CF Kit (6" & Cold) Facilities Transfort Administrz Money Room 7 7 Replace lamp w/ 16W R30 Screw in CF Facilities Transfort Administrz Money Room 3 3 Retrofit fixture w/ (3) F32T8lADV841/EW/LUALTO 28W lamps & 3L ]OR LP Facilities Transfort Adminislre Money Room 1 0 Sensor Spec CUS2000 1 Facilities Transfort Administrz Fuel Island Canopy 9 0 No Retrofit at this time Facilities Transfort Administr¢ Admin Modular Office 6 6 Retrofit fixture w/ (4) F32TWADVIAVEW/LUALTO 28W lamps, 4L OR LP Facilities Transfort Administrz Admin Modular Office 1 0 Sensor Spec CIR-2R 1 Facilities Transfort Administrz Admin Modular RR 1 1 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L OF LP Facilities Transfort Administr¢ Admin Modular RR 1 0 Sensor Spec WSIR 1 Facilities Transfort Administrz Admin Modular Office 1 1 Retrofit fixture wl (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities Transfort Administrz Admin Modular Office 1 1 Retrofit fixture wl (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities Transfort Administrz Admin Modular Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities Transfort Administr Admin Modular Office 2 2 Retrofit fixture w/ (4) F32T8/ADV&4l/EW/LUA1-TO 28W lamps, 4L IOP LP Facilities Transfort Administrz Admin Modular Office 1 0 Sensor Spec WSIR i Facilities Transfort Administrz Admin Modular Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP (Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fists Proposed Retrofit Description Sensor Type Facilities Transfort Administre Admin Modular Office 1 0 Sensor Spec WSIR Facilities Transfort Administrz Exterior Modular 2 2 Install New Enerlron 7800L 13W OF VVP Facilities Transfort Adminishr Exterior Main 7 7 install new 21 13W OF Can (Cold Temperature) Facilities Transfort Administre Exterior Main 13 0 No Retrofit at this time Facilities Transfort AdministrE Exterior Main 4 0 No Retrofit at this time Facilities Transfort Administr Exterior Main 12 0 No Retrofit at this time Facilities Transfort Administre Garage West 1 0 Sensor Spec VEND MISER - Golf Collindale Golf Cow Front Stairs 104 4 0 No Retrofit at this time Golf Collindale Golf Cow Lobby B01 4 0 No Retrofit at this time Golf Collindale Goff Cow Lobby 601 1 0 No Retrofit at this time Golf Collindale Golf Com Lobby 601 1 0 No Retrofit at this time Golf Collindale Golf Cow Phone 802 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 OP -LP Golf Collindale Golf Cow Mech 603 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Golf Collindale Golf Cow Mach 804 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Golf Collindale Golf Cow Mans Locker 85 9 0 No Retrofit at this time Golf Collindale Golf Com Mans Locker 85 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Golf Collindale Golf Com Mans Locker 85 2 0 No Retrofit at this time Golf Collindale Golf Com Mans Locker B5 2 0 No Retrofit at this time Golf Collindale Golf Cow Womens Locker B6 4 0 No Retrofit at this time Golf Collindale Golf Cow Womens Locker B6 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Golf Collindale Golf Cow Womens Locker B6 3 0 No Retrofit at this time Golf Collintlale Golf Cow Womens Locker 86 2 0 No Retrofit at this time Golf Collindale Golf Cow Lounge 87 4 4 Retrofit fixture w/(3)F32T8/ADV841/EW/LL/ALTO 28W lamps &3L IOP LP Golf Collindale Golf Cow Hall 88 9 9 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Golf Collindale Golf Cow Hall 88 5 0 No Retrofit at this time Golf Colfindale Golf Cow Storage B9 2 2 Retrofit fixture w/ (2) F32TBIADV841/EW/LUALTO 28W lamps & 2L IOP-LP Golf Colfindale Golf Cow Mech B10 3 3 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Golf Collindale Golf Co., Wet B11 2 2 Retrofit fixture w/ (3) F32TB/ADV841/EW/LUALTO 28W lamps &3L IOP LP Golf Collindale Goff Com Repair Bit 4 4 Retrofit fixture W(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Goff Collindale Goff Cow Cart Storage Bl S 26 26 Retrofit fixture w/(2)F32TB/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Goff Collindale Golf Cow Cart Storage B15 2 0 No Retrofit at this time Golf Collindale Golf Cow Back Stairs 127 2 0 No Retrofit at this time Golf Collindale Golf Cow Attic 9 9 Retrofit fixture w/(2)F32TB/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Golf Collindale Golf Com Veslibule 100 2 0 No Retrofit at this time Golf Collindale Golf Cow Vestibule 100 4 0 No Retrofit at this time Golf Collindale Golf Cow Lobby 101 2 0 No Retrofit at this time Golf Collindale Golf Cow lobby 101 1 0 No Retrofit at this time Golf Collindale Golf Cow Coats 102 2 0 No Retrofit at this time Golf Collindale Golf Com Entry 103 1 0 No Retrofit at this time Golf Collindale Golf Com Entry 103 1 0 No Retrofit at this time Golf Collindale Golf Cow Entry 103 1 0 No Retrofit at this time Golf Collindale Golf Cow Private Dining 105 9 0 No Retrofit at this time Golf Collindale Golf Cow Private Dining 105 2 0 No Retrofit at this time Golf Collindale Golf Cow Private Dining 105 2 0 No Retrofit at this time Golf Collindale Golf Cam Private Dining 105 6 0 No Retrofit at this time Golf Collindale Golf Com Private Dining 105 16 0 No Retrofit at this time Golf Collindale Golf Com Storage 123 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP (Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixes Exist Fills Proposed Retrofit Description Sensor Type Sensor Qty Golf Collindale Golf Cow Lounge 107 46 0 No Retrofit at this time Golf Collindale Golf Cow Lounge 107 16 0 No Retrofit at this time Golf Collindale Golf Cow Lounge 107 4 0 No Retrofit at this time Golf Collindale Golf Cow Lounge 107 4 0 No Retrofit at this time Golf Collindale Golf Cow Bar 108 4 0 No Retrofit at this time Golf Collindale Golf Cow Bar 108 4 0 No Retrofit at this time Golf Collindale Golf Cow Bar 108 3 0 No Retrofit at this time Golf Collindale Golf Count Bar 108 3 3 Retrofit fixture w/ (1) F321-8/ADV841/EW/LUALTO 28W lamps & I [OP -LP Golf Collindale Golf Cow Bar Controls 108 1 1 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps. 4L OP LP Golf Collindale Golf Com Bar Storage 118 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Golf Collindale Golf Cow Kitchen 1191120 12 12 Retrofit fixture w/(3)F32TB/ADV841/EW/LUALTO 28W lamps &3L I0P LP Golf Collindale Golf Cow Kitchen 1191120 4 4 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALT028W lamps &2L I0P-LP Golf Collindale Golf Cow Kitchen 119/120 3 3 Install new 42W CF Jar Fixture Golf Collindale Golf Cow Kitchen 1191120 2 2 Install new 42W CF Jar Fixture Golf Collintlale Golf Com Freezer 2 2 Retrofit fixture w/ (2) F32T8/ADV841/ALTO lamps, 2L IOP-Sind. & 4' Socket Plate Kit (Cold) Golf Collindale Golf Cow Freezer 1 1 Remove Lamp Golf Collindale Golf Cow Sink 1 0 No Retrofit at this time Golf Collindale Golf Cow Beer Cooler 1 1 Install New Enertron 7800L 13W CIF AP Golf Collindale Golf Cow Corridor 109 11 0 No Retrofit at this time Golf Collindale Golf Gout Grader 109 2 0 No Retrofit at this time Golf Collindale Golf Com Worriers RR 116 7 0 No Retrofit at this time Golf Collindale Golf Com Worriers RR 116 2 0 No Retrofit at this time Golf Collindale Golf Cow Janitor 104 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 21 GP -LP Golf Collindale Golf Cow Mens RR 115 7 0 No Retrofit at this time Golf Collindale Golf Com Mans RR 115 2 0 No Retrofit at this time Golf Collindale Golf Cam Pro Shop 110 30 0 No Retrofit at this time Golf Collindale Golf Com Pro Shop 110 8 0 No Retrofit at this time Golf Collindale Golf Cow Pro Shop 110 1 0 No Retrofit at this time Golf Collindale Golf Cow Pro Shop 110 2 0 No Retrofit at this time Golf Collindale Golf Cow Dressing Room 111 1 0 No Retrofit at this time Golf Collindale Golf Co., Office 112 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Golf Collindale Golf Cow Storage 113 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L I0P LP Golf Collindale Golf Cow Riser 1 1 Retrofit Wore w/(2)F32T8/ADV841/EW/LL/ALT028W lamps &2L I0P-LP Golf Collindale Golf Cow Back Ramp 2 0 No Retrofit at this time Golf Collindale Golf Cow Soffit Lights 20 0 No Retrofit at this time Golf Collindale Golf Cow Step Lights 12 0 No Retrofit at this time Golf Collindale Golf Cow Dec Sconces 2 0 No Retrofit at this time Golf Collindale Golf Cow Drive Way 3 0 No Retrofit at this time Golf Collindale Golf Gout Parking 2 2 Retrofit fixture w/ (2) 200W Pulse Start Metal Halide Lamps & Ballast Golf Collindale Golf Com Parking 2 2 Retrofit fixture w/ 200W Pulse Start Metal Halide Lamp & Ballast Golf Collindale Golf Com Parking 6 6 Retrofit fixture w/ 200W Pulse Start Metal Halide Lamp & Ballast Golf Collindale Golf Cow Parking 2 2 Retrofit fixture w/ 200W Pulse Start Metal Halide Lamp & Ballast Golf Southridge Golf Storage Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Golf Southridge Golf Storage Room 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 21 OP-Stnd, & B' Industrial H Golf Southridge Goff Furnace / Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/WALTO 28W lamps, 2L OP -Sind, & V Industrial H Golf Southridge Golf Furnace /Storage 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Golf Southridge Golf RR 1 0 No Retrofit at this time Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fists Exist Fixts Proposed Retrofit Description Sensor Type Sensor Qty Golf Southridge Golf RR 1 1 Install new 2' Vanity Fixture w/ (2) F17TS71-841/ECO lamps- QHE Sind Blist Golf Southridge Golf Repair Shop - Retail 5 0 No Retrofit at this time Golf Southridge Golf Repair Shop - Retail 5 5 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L I0P-LP Golf Southridge Golf Repair Shop - Retail 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Golf Southridge Golf Hall 1 1 Retrofit fixture w/(2)F32TS/ADV841/EW/LUALT028W lamps &2L I0P-LP Golf Southridge Golf Hall 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Golf Southridge Golf Cart Garage- Drinks 1 1 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP Send, & 8' Socket Plat, Golf Southridge Golf Cart Garage- Drinks 1 1 Replace lamp w/ 16W R30 Screw in CF Golf Southridge Golf Cart Garage - Drinks 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P4LP Golf Southridge Golf Office 2 2 Retrofit fixture w/ (2) 1`32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Golf Southridge Golf Office 1 1 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALT0 28W lamps, 21 IOP Sind, delamped Golf Southridge Golf DHW 1 1 Replace lamp w/ 13W Screw in OF Golf Southridge Golf Office- Pro 3 3 Replace lamp w/ 16W R30 Screw in OF Golf Southridge Golf Office - Pro 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Golf Southridge Golf Pro Shop 2 2 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALT0 28W lamps & 2L IOP-LP Golf Southridge Golf Pro Shop 27 0 No Retrofit at this time Golf Southridge Golf Pro Shop 3 0 No Retrofit at this time Golf Southridge Golf Pro Shop 6 0 No Retrofit at this time Golf Southridge Golf Pro Shop 4 0 No Retrofit at this time Golf Southridge Golf Storage Room 1 1 Install New 13W OF Drum Fixture Golf Southridge Golf Entry/Hall 2 2 Replace lamp w/ (4) 18W Screw in OF Golf Southridge Golf Entry / Hall 2 2 Install new Green LEO Exit Golf - Southridge Golf Entry/Hail 1 1 Replace lamp w/ 16W R30 Screw in OF Golf Southridge Golf Meng RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Golf Southridge Golf Meng RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Golf Southridge Golf Meng RR 1 0 No Retrofit at this time Golf Southridge Golf Meng RR 1 0 Sensor Spec WSIR t Golf Southridge Golf Womens RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EWAUALT0 28W lamps & 2L IOP-LP Golf Southridge Golf Womens RR i i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Golf Southridge Golf Womens RR 1 0 No Retrofit at this time Golf Southridge Golf Womens RR 1 0 Sensor Spec WSIR 1 Golf Southridge Golf Restaurant 17 17 Retrofit w/ 26W CF Downiight Kit (6" & Dimmable) Golf Southridge Golf Restaurant 1 i Install new Green LED Exit w/ Battery Back up Golf Southridge Golf Bar 8 8 Retrofit w/26W OF Downlight Kit (6" & Dimmable) Golf Southridge Golf Bar 3 3 Retrofit w/ 26W CF Downlight Kit (6" & Dimmable] Golf Southridge Golf Tap Display 3 3 Retrofit w/ 26W CF Downlight Kit (6" & Dimmable) Golf Southridge Golf Kitchen 8 6 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps & (112) 4L IOP-LP(Tubeguard Golf Southridge Golf Kitchen 2 2 Retrofit fixture w/(2)F32T8/ADV84lfEW/LUALTO 28W lamps &2L I0P-LP (Tubeguards) Goff Southridge Golf Kitchen 2 2 Install new 42W OF Jar Fixture Golf Southridge Golf Dry Storage 1 1 Install New 2L 13W OF Drum Fixture Golf Southridge Golf Cart Garage - New 26 26 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L I0P-LP Golf Southridge Golf Cart Garage, New 2 0 Sensor Spec CIR 2 Golf Southridge Golf Maintenance Shop 3 3 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP Stnd, & B' Socket Plat, Golf Southridge Golf Maintenance Shop 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Golf Southridge Golf Maintenance Shop 3 3 Install new 4' 2L28T8 Strip - IOP-Stud Golf Southridge Golf Maintenance Shop 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Golf Southridge Golf Maintenance Shop 2 2 Install new 4' 2L28T8 Strip - IOP-Stud Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fixts Proposed Retrofit Description Sensor Type Sensor Qty Golf Southridge Golf Storage Room 1 1 Install new 2L 13W CF Omm Fixture Golf Southridge Golf Jacket Room 1 1 Install new 2L 13W CF Drum Fixture Golf Southridge Golf RR 1 1 Install new 2' Vanity Fixture w/ (2) F17T8,7L841/EC0 lamps- QHE LP Bllst Golf Southridge Golf Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W Iamps & 2L IOP-LP Golf Southridge Golf Office 1 0 Sensor Spec WSIR 1 Golf Southridge Golf Main Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, delamped Golf Southridge Golf Main Office 1 0 Sensor Spec WSIR 1 Golf Southridge Golf Tractor Storage 1 1 Install New 13W CF Drum Fixture Golf Southridge Golf Grinding Room 1 1 Install new 4' 2L28T8 Strip - IOP-Stud Golf Southridge Golf Equipment Barn 9 9 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stnd, & 8' Industrial H Golf Southridge Golf Fertilizer Storage 1 1 Install new 2L 26W CF Drum Golf Southridge Golf Exterior - Maintenance 3 3 Install new 42W CF Wallpack Golf Southridge Golf Exterior- Maintenance 1 1 Install New Enertron 7800L 13W CF WP Golf Southridge Golf Exterior - Cart Barn 6 0 No Retrofit at this time Golf Southridge Golf Exterior - Main Building 1 0 No Retrofit at this time Golf Southridge Golf Exterior- Main Building 11 11 Replace lamps w/ (2) 8W R30 Screw in Cold Cathode lamps Goff Southridge Golf Exterior- Main Building 4 4 Install new 42W Wall pack Golf Southridge Golf Exterior- Main Building 1 1 Replace lamp w/ 16W R30 Screw in CF Golf Southridge Golf Exterior- Main Building 4 4 Replace lamp w/ 16W R30 Screw in CF Golf Southridge Golf Exterior - Main Building 2 0 No Retrofit at this time Golf Southridge Golf Exterior- Main Building 6 0 No Retrofit at this time Golf Southridge Golf Maintenance Shop 1 0 Sensor Spec VEND MISER- 1 Utilities Utilities A/B Warehouse 562 18 18 Retrofit future w/ (4) F32T8/ADV8411EWILUALTO 28W lamps, 4L IOP Stnd, & 8' Industrial H, Utilities Utilities Ar6 Warehouse 562 1 1 Retrofit future w/ (4) F32T8/ADV8411EW/LUALT0 28W lamps, 4L IOP Smd, & 8' Industrial F Utilities Utilities A/B Warehouse 562 1 0 No Retrofit at this time Utilities Utilities AS Dock Lights 11 11 Install new 8'4128T8 Vapor Tight Fixture - IOP-HP (850K) Utilities Utilities A/B Office 565 2 2 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALT0 28W lamps, 2L IOP Stnd, 2x4 Ref Utilities Utilities AlB Office 565 1 0 Sensor Spec WSIR 1 Utilities Utilities A/B Office 564 6 6 Retrofit future w/ (2) F32T8/ADVSH1EW/LUALT0 28W lamps. 2L IOP Stnd, 2x4 ReFl Utilities Utilities A/B Office 564 1 0 Sensor -Spec CIR 1 Utilities Utilities A/B Office 563 7 7 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 ReFl Utilities Utilities A/B Office 563 1 0 Sensor Spec CIR 1 Utilities Utilities A/B Office 563 2 2 Retrofit fixture w/ (2) F32T8/ADV8411EW1LUALTO 28W lamps. 2L IOP Stnd, 2x4 Ref Utilities Utilities A/B Office 563 1 0 Sensor Spec WSIR 1 Utilities Utilities AID Corridor 565 3 3 Retrofit future w/(2)F32T8/ADV8411EW/LUALT028W lamps, 2L POP Stnd, 2x4 ReFl Utilities Utilities A/B Corridor 555 1 1 Install new Green LED Exit w/ Battery Back up Utilities Utilities A18 Conference 553 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Ref Utilities Utilities A/B Conference 553 1 0 Sensor Spec WSIR 1 Utilities Utilities A/B RR 552 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities AIR Copy 551 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps, 2L IOP Stnd, 2x4 ReFl Utilities Utilities A/B Copy 551 1 0 Sensor -Spec WSIR 1 Utilities Utilities NB Office 550 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Stnd, 2x4 ReFl Utilities Utilities A/B Office 556 2 2 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALT0 28W lamps, 2L IOP Stnd, 2x4 Refl Utilities Utilities A/B Mach Rm 557 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps. 2L I0P Strut, 2x4 Ran Utilities Utilities A/B Mech Rm 557 1 0 Sensor Spec WSIR 1 Utilities Utilities A/B Corridor 500c 13 0 No Retrofit at this time Utilities Utilities A/B Warehouse 560 109 109 Retrofit fixture w/(2)F32T8/ADV8411EW/LUALTO 28W lamps &2L IOP-LP (High Install) Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Forts Proposed Retrofit Description Sensor T Utilities Utilities A/B Warehouse 560 1 0 No Retrofit at this time Utilities Utilities A/B Warehouse 560 Cage 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities A/B Garage 570 11 11 Install new 4' 2L28T8 Vapor Tight Fixture- IOP-Stud (850K) Utilities Utilities A/B Garage 570 Cages 6 6 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities AIR Garage 570 Cages 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Ref Utilities Utilities AB Garage 570 Cages 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd. delamped Utilities Utilities A/B Cages 9 9 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Storage 4 4 Retrofit Wore w/(2)F32T8/ADV841/EW/LL/ALTO 28W tamps &(1/2)4L IOP-LP (Long ??) Utilities Utilities A/B Storage 1 0 Sensor Spec TIMER Utilities Utilities A/B Storage 4 4 Retrofit fixture w/ (2) F32TS/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP (Long??) Utilities Utilities A/B Storage 1 0 Sensor Spec TIMER Utilities Utilities A/B Meter Shop/Office 14 0 No Retrofit at this time Utilities Utilities A/B Meter Shop / Office 1 1 Retrofit fixture w/ (2) F32TB/ADV841/EWILLIALTO 28W lamps & 2L IOP-LP Utilities Utilities AS Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities A/8 Office 1 0 Sensor Spec WSIR-2P Utilities Utilities ArB Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps. 1L IOP LP, & 2L IOP LP (Dua Utilities Utilities AIR Office 1 0 Sensor Spec WSIR-2P Utilities Utilities AB Office 3 3 Retrofit fixture w/13)F32T8/ADV841/EW/LUALTO 28W lamps, I IOP LP,&2L IOP LP (Due Utilities Utilities A/B Office 2 0 No Retrofit at this time Utilities Utilities AS Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP (Very High) Utilities Utilities ArB Break Room 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Bell Utilifies Utilities A/B Break Room 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 21 IOP LP (Due Utilities Utilities A/B Office i 0 Sensor Spec WSIR-2P Utilities Utilities A/B . Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP. & 2L IOP LP (Due Utilities Utilities A/B Office 1 0 Sensor Spec WSIR-2P Utilities Utilities A/B Computer Equipment 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Ref Utilities Utilities A/B Computer Equipment 1 0 Sensor Spec WSIR Utilities Utilities A/B Ice Machine 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, delamped Utilities Utilities A/B Ice Machine 1 0 Sensor Spec WSIR Utilities Utilities A/B Vending 1 0 No Retrofit at this time Utilities Utilities A/B Corridor 32 0 No Retrofit at this time Utilities Utilities A/B Come., 1 0 No Retrofit at this time Utilities Utilities A/B Conidor 5 5 Install new Green LED Exit w/ Battery Back up Utilities Utilities A/B Office 535 6 6 Retrofit fixture w/ (2) F32T8/ADVS41/EW/LL/ALT0 28W lamps, 21 IOP Stnd, 2x4 Ref Utilities Utilities A/B Office 537 6 0 No Retrofit at this time Utilities Utilities NEI Office 536 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Ref UBiifies Utilities A/B Office 536 1 0 Sensor Spec WSIR Utilities Utilities A/B Office/Electrical 2 2 Retrofit Wore w/(2)F32T8/ADV&41/EW/LUALTO 28W lamps, 2L IOP Sind. delamped Utilities Utilities A/B Electrical/UPS 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, delamped Utilities Utilities A/B Office 6 6 Retrofit fdure w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, IL IOP LP,&2L IOP LP (Due Utilities Utilities A/B Office 1 0 Sensor Spec GDT1000 Utilities Utilities A/B Storage 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALTO 28W lamps,(0.5) 4L IOP Sind, &delampe Utilities Utilities AfS Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Sind, & delamped Utilities Utilities A/B Storage 6 0 No Retrofit at this time Utilities Utilities A/B Storage 1 1 Replace Lamp w/ 23W Screw in CF (Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Finds Exist Fixts Proposed Retrofit Description Sensor Type Sensor City Utilities Utilities AIS Open Office 460 16 16 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I [OR LP, & 2L [OR LP (Due Utilities Utilities A/B Open Office 450 2 0 Sensor Spec CUS1000 2 Utilities Utilities A/B Office 47D 2 2 Retrofit fixture w/ (3) F32T8/AOV841/EW/LUALTO 28W lamps, I IOP LP, & 2L IOP LP (Dua Utifities Utilities A/B Office 47D 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Office 472 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities A/B Office 472 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Office 474 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities A/B Office 474 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities AIR Once 456 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/WALTO 28W lamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities AS Office 456 3 0 No Retrofit at this time Utilities Utilities A/B Office 456 1 0 Sensor Spec CIR 1 Utilities Utilities A/B Break 454 4 0 No Retrofit at this time Utilities Utilities A/B Mans RR 453 3 0 No Retrofit at this time Utilities Utilities A/B Mans RR 453 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Utilities Utilities A/B Mena RR 453 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps & 2L IOP-LP Utilities Utilities AB Mena RR 453 1 0 Sensor Spec CUS1000 i Utilities Utilities A/B Storage 1 0 No Retrofit at this time Utilities Utilities A/B Mech Run 125 10 10 Retrofit fixture w/(2)F32T8/ADV841/EW/LVALT028WIamps&2L IOP-LP Utilities Utilities A/B Mech Run on Roof 4 4 Install New 2L 13W CF Drum Fixture Utilities Utilities A/B Mach Run on Roof 1 0 No Retrofit at this time Utilities Utilities A/B Library 465 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L IOP LP Utilities Utilities A/B Office 476 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L ]OR LP, & 2L IOP LP (Due Utilities Utilities A/B Office 476 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Office 478 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps, 1L OR LP, & 2L IOP LP (Due Utilities Utilities A/B Office 480 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 2L ]OR LP (Dua Utilities Utilities A/B Office 480 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities AID Office 482 4 4 Retrofit fixture w/ (3) F32T81ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 2L POP LP (Due Utilities Utilities A/B Entry 2 0 No Retrofit at this time Utilities Utilities A/B Office 484 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I IOR LP, & 2L IOP LP (Due Utilities Utilities A/B Office 484 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Office 486 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I [OR LP, & 2L [OR LP (Dua Utilities Utilities A/B Office 486 1 0 Sensor Spec WSIR-2P i Utilities Utilities A/B Office 488 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I IOP LP, & 2L IOP LP (Due Utilities Utilities A/B Office 488 1 0 Sensor Spec WSIR-2P i Utifities Utilities A/B Office 492 2 2 Retrofit fixture w/ (3) F32T8/ADV8411EW/LUALTO 28W lamps, I IOP LP, & 2L IOP LP (Due Utilities Utifities A/B Office 492 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Office 494 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities A/B Office 494 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Office 496 4 4 Retrofit fixture w/ (3) F32T8/ADV84VEW/LUALTO 28W lamps, I IOP LP, & 2L IOP LP (Due Utilities Utilities AS Office 496 1 0 Sensor Spec CIR 1 Utilities Utilities A/B Copy 483 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I IOP LP, & 2L IOP LP (Due Utilities Utilities A/B Conference 481 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I POP LP, & 2L IOP LP (Due Utilities Utilities A/B Conference 481 1 0 Sensor Spec WSIR 1 Utilities Utilities A/B Office 3 3 Retrofit fixture w/ (3) 1`32T8/ADV841/EW/LUALTO 28W lamps, I IOP LP, & 2L ]OR LP ([)us Utilities Utilities A/B Office 1 0 Sensor Spec WSIR-2P i Utilities Utilities A/B Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities A/B Office 1 0 Sensor Spec WSIR-2P 1 Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Finds Exist Fixts Proposed Retrofit Description Sensor Type Sensor Cry Utilities Utilities A/B Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, lL IOP LP, & 2L IOP LP (Due Utilities Utilities A/B Office 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/6 Office 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I IOP LP, & 2L IOP LP (Due Utilities Utilities A/S Office 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/6 Office 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I IOP I.P. & 2L IOP LP (Due Utilities Utilities AB Office 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Open Office 10 10 Retrofitfixture w/ (3) F32T8/ADV841/EW)LUALTO 28W lamps & 3L IOP LP Utilities Utilities A/B Open Office 18 0 No Retrofit at this time Utilities Utilities A/B Open Office 12 12 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps &1LIOP-UP Utilities Utilities A/B Open Office 2 2 Install new Green LED Exit w/ Battery Back up Utilities Utilities A/B Open Office 2 2 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 2L IOP-LP Utilities Utilities A/B Office 446 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 446 3 0 No Retrofit at this time Utilities Utilities A/B Office 446 2 0 No Retrofit at this time Utilities Utilities A/B Cubicles 445 8 8 Retrofit fixture w/(3)F32T81ADV841/EW/LVALTO 28W[amps &3L IOP LP Utilities Utilities A/B Cubicles 445 4 0 No Retrofit at this time Utilities Utilities A/B Office 444 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 444 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities A/B Office 442 2 0 No Retrofit at this time Utilities Utilities A/B Office 442 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 442 1 1 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps &iL IOP-LP Utilities Utilities A/B Cubicles 8 8 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities A/B Office 3 0 No Retrofit at this time Utilities Utilities A/B Office 4 0 No Retrofit at this time Utilities Utilities A/B Office 2 0 No Retrofit at this time Utilities Utilities A/B Office 4 0 No Retrofit at this time Utilities Utilities A/B Cubicles 5 0 No Retrofit at this time Utilities Utilities A/B Office 6 0 No Retrofit at this time Utilities Utilities A/B Office 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Office 1 0 No Retrofit at this time Utilities Utilities A/B Office 5 0 No Retrofit at this lime Utilities Utilities AB Office 2 0 No Retrofit at this time Utilities Utilities A/B Halls 17 0 No Retrofit at this time Utilities Utilities A/B Halls 8 8 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps &1L IOP-LP Utilities Utilities A/B Halls 2 2 Install new Green LED Exit w/ Battery Back up Utilities Utilities A/B Office 6 0 No Retrofit at this time Utilities Utilities A/B Office 4 0 No Retrofit at this time Utilities Utilities A/B Office 2 0 No Retrofit at this time Utilities Utilities A/B Conference 1 i Retrofit fixture w/ (2) 1`32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities A/B Conference 2 0 No Retrofit at this time Utilities Utilities A/B Conference 2 0 No Retrofit at this time Utilities Utilities A/S Conference 7 0 No Retrofit at this time Utilities Utilities A/B Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities A/B Office 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Office 2 0 No Retrofit at this time Utilities Utilities A/B Office 1 0 Sensor Spec WSIR 1 Utilities Utilities A/B Office 2 0 No Retrofit at this time Johnson Controls, Inc. 5%57 N. Green Bay Avenue Post Office 13ox >91 Milwaukee, VVI 53201 0591 rel. 414/524 12.00 H S N DELEGATION OF AUTHORITY P LS fhe undersigned, President of Johnson Controls, Inc., a Wisconsin corporation (the "Company"), pursuant to the authority vested in him by a certain resolution adopted by the Board of Director of the Company on January 23, 1980, hereby authorizes: Catherine 13. Hutson Hays Companies 1200 N. Mayfair Road, Suite 100 Milwaukee, WI53226 to perform, on behalf'of the Company, the acts described below: To execute, seal and deliver, as attorney -in -fact for the Company, surety bonds forwarded to Flays Companies by a Company authorized surety that do not exceed Two Million Dollars (`n2,000,000,00) that are necessary and proper in carrying on the business of the Company. This authority shall remain in full force and effect far six (6) months from the date of issue. Signed at Milwaukee, Wisconsin, this �% _ day ofAAA 'f OC)% f Keith E. Wa,Jeff,-tiresident Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fills Proposed Retrofit Description Sensor Type Sensor City Utilities Utilities NB Office 1 0 Sensor Spec WSIR i Utilities Utilities NB Halls 6 0 No Retrofit at this time Utilities Utilities A/B Worriers RR 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/WALTO 28W lamps & 2L IOP-LP Utilities Utilities NB Womens RR 3 0 No Retrofit at this time Utilities Utilities AID Womens RR 1 0 Sensor Spec CUS1000 1 Utilities Utilities NB Conference 440 18 0 No Retrofit at this time Utilities Utilities A/B Conference 440 5 0 No Retrofit at this time Utilities Utilities NB Conference 440 2 0 No Retrofit at this time Utilities Utilities A/B Conference 440 3 0 No Retrofit at this time Utilities Utilities A/B Conference 440 1 0 Sensor Spec CUS1000 1 Utilities Utilities A/B Conference 440 1 0 Sensor Spec CDT2000 i Utilities Utilities NB Storage 3 3 Retrofit Wore w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L hDP-LP Utilities Utilities NB Storage 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALT028W lamps &2L IOP-LP Utilities Utilities A/B Storage 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Storage 1 1 Retrofit fixture w/ (2) F32TmADV841/EW/LL/ALT0 28W lamps & 21 IOP-LP Utilities Utilities NS Copy Room 425 6 6 Retrofit fixture w/ (3) F32T8/ADV84VEW(LUALTO 28W lamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities NB Copy Room 425 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities NB Conference 400 5 0 No Retrofit at this time Utilities Utilities NB Conference 400 5 0 No Retrofit at this time Utilities Utilities NB Conference 400 4 0 No Retrofit at this time Utilities Utilities NB Conference 400 2 0 No Retrofit at this time Utilities Utilities NB Conference 400 1 0 Sensor Spec WCDT1500 1 Utilities Utilities NB Corridor 4 0 No Retrofit at this time Utilities Utilities A/B Corridor 1 0 No Retrofit at this time Utilities Utilities NB Closet 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L IOP-LP Utilities Utilities NB Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Office 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Utilities Utilities NB Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities NB Office 2 0 No Retrofit at this time Utilities Utilities NB Once 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities NB Office 1 0 No Retrofit at this time Utilities Utilities NB Office 1 0 No Retrofit at this time Utilities Utilities NB Office 2 0 No Retrofit at this time Utilities Utilities NB Office 2 0 No Retrofit at this time Utilities Utilities NB Copy 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I IOP LP, & 2L IOP LP (Due Utilities Utilities NB Copy 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities NB Corridor 2 0 No Retrofit at this time Utilities Utilities NB Open Office 7 7 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W ]amps, IL IOP LP, & 2L IOP LP (Due Utilities Utilities NB Open Office 11 0 No Retrofit at this time Utilities Utilities NB Open Office 8 8 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&(1/2)4L IOP-LP(VeryHigh) Utilities Utilities NB Office 4 4 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, IL IOP LP, &2L IOP LP (Due Utilities Utilities NB Office 1 0 Sensor Spec CIR i Utilities Utilities NB Computer 6 6 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUAU0 28W tamps, 1L IOP LP, & 2L IOP LP (Due Utilities Utilities NB Conference 4 0 No Retrofit at this time Utilities Utilities NB Conference 8 0 No Retrofit at this time Utilities Utilities NB Conference 1 0 Sensor Spec WSI R-2P 1 Utilities Utilities NB RR i i Retrofit fixture w/ (2) F17T8/fL841/ALTO Lamps & 2L IOP-LP Bllst Attachment #1 - City-wide Lighting Scope Group Site Name Area Description FWs Exist Fists Proposed Retrofit Description Sensor Type Sensor qty Utilities Utilities NB RR 1 0 No Retrofit at this time Utilities Utilities NB RR 1 0 No Retrofit at this time Utilities Utilities NB RR 1 0 Sensor Spec WSIR 1 Utilities Utilities A/B Mens RR 5 0 No Retrofit at this time Utilities Utilities NB Mans RR 7 7 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28Wlamps&2L IOP-LP Utilities Utilities A/B Mans RR 1 0 Sensor Spec CUS2000 1 Utilities Utilities NB Storage 1 0 No Retrofit at this time Utilities Utilities A/B Office 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, lL IOP LP, &2L IOP LP (Due Utilities Utilities NB Once 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities NB Janitor 1 0 No Retrofit at this time Utilities Utilities NB Warrens RR t 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Utilities Utilities NB Womens RR t 0 No Retrofit at this time Utilities Utilities AIR Womens RR 1 0 No Retrofit at this time Utilities Utilities NB Open Once 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Shei 2x4 Ref Utilities Utilities NB Open Office 1 0 Sensor Spec CUS1000 1 Utilities Utilities A/B Cafeteria / Break 8 8 Replace lamp w/ 16W R30 Screw in OF Utilities Utilities NB Cafeteria/Break 5 5 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps. 2L 10P Sind, 2x4 Ran Utilities Utilities NB Cafeteria/Break 8 8 Retrofit fixture w/(2)F32T8/ADV84t/EW/LUALT028W lamps & (1/2) 4L IOP-LP Utilities Utilities A/B Corridor 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W tamps, 2L IOP Stnd, & 2x4 Roll Utilities Utilities NB Once 517 4 4 Retrofit fixture wl (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP - Dual SwAcher Utilities Utilities NB Office 517 1 0 Sensor Spec WSIR-2P 7 Utilities Utilities NB Office 507 4 4 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALT0 28W lamps, (2) 2L IOP LP - Dual Switches Utilities Utilities AID Once 507 t 0 Sensor Spec WSIR-2P 1 Utilities Utilities AIR Open Office 506 3 3 Retrofit fixture w/ (4) F32T8/ADV84t/EW/LUALTO 28W lamps, 41 IOP LP Utilities Utilities AIR Office 512 4 4 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALT0 28W lamps, (2) 21 IOP LP- Dual Switches Utilities Utilities A/B Office 512 1 0 Sensor Spec CIR 1 Utilities Utilities A/B Office 511 2 2 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L HOP LP - Dual Switche( Utilities Utilities NB Once 511 1 1 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP - Dual Switche( Utilities Utilities A/B Office 511 1 0 Sensor Spec WSIR-2P 1 Utilities Utilities A/B Office 508 2 2 Retrofit fixture w/(4)F32T8/ADV84t/EW/LUALT028W lamps, (2)2L IOP LP - Dual Switche( Utilities Utilities NB Office 508 1 1 Retrofit fixture w/(4)F32T8/ADV841/EW/LL/ALTO 28W lamps, (2) 2L HOP LP - Dual Switche( Utilities Utilities NB Office 508 1 0 Sensor Spec CIR t Utilities Utilities NB Halls 4 0 No Retrofit at this time Utilities Utilities NB Halls 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Utilities Utilities NB Hails 12 0 No Retrofit at this time Utilities Utilities NB Hails 1 t install new Green LED Exit w/ Battery Back up Utilities Utilities NB Hails 1 0 No Retrofit at this time Utilities Utilities NB Hails 6 0 No Retrofit at this time Utilities Utilities NB Office 2 2 Retrofit fixture w/ (2) F32TB/ADV841/EW/LUALTO 28W lamps. 2L IOP Stnd, 2x4 Deep Ran Utilities Utilities NB Office 2 0 No Retrofit at this time Utilities Utilities NB Once 1 0 Sensor Spec CIR 1 Utilities Utilities NB Vault 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 21 IOP-LP Utilities Utilities NB Conference 365 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Deep Ran Utilities Utilities NB Conference 365 2 0 No Retrofit at this time Utilities Utilities NB Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV84t/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities NB Corridor 7 7 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Womens Locker 6 6 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps & 1 L IOP-LP Attachment #1 - City-wide Lighting Scope Utilities Utilities A/B Worsens Locker 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &1112)4L IOP-LP Utilities Utilities NB Womens Locker 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28Wiamps&2L IOP-LP Utilities Utilities NB Worriers Locker 2 0 No Retrofit at this time Utilities Utilities NB Womens Locker 2 0 No Retrofit at this time Utilities Utilities N6 Mens Locker 2 2 Retrofit fixture w/ (1) F32T8/ADV841/EW/LL/ALTO 28W lamps & (112) 21. IOP-LP Utilities Utilities AB Mens Locker 1 i Retrofit fixture w/ (1) F32T8/ADV841/EW/L1JA1-TO 28W lamps & 1L IOP-LP Utilities Utilities NB Mens Locker 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/L1JA1-T0 28W lamps & (1/2) 41 IOP-LP Utilities Utilities NB Mens Locker 1 1 Retrofit fixture w/ (2) F17T8/7L841/ALTO Lamps & (1/2) 41 IOP-LP Bllst Utilities Utilities A/B Conference 6 6 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L IOP-LP Utilities Utilities NB Conference 9 0 No Retrofit at this time Utilities Utilities NB Office 2 2 Retrofit fixture w/ (2) F32T81ADV841/EW/LUALTO 28W lamps, 2L IOP Smd, 2x4 Deep Rea Utilities Utilities AIR Office 1 0 Sensor Spec WSIR Utilities Utilities NB Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/L1JA1-TO 28W lamps, 2L IOP Sind, 2x4 Deep Bell Utilities Utilities NB Once 1 0 Sensor Spec WSIR Utilities Utilities NB Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP Sind, 2x4 Deep Bell Utilities Utilities NB Office 1 0 Sensor Spec CIR Utilities Utilities NB Entry Lobby 11 0 No Retrofit at this time Utilities Utilities NB Entry Lobby 8 0 No Retrofit at this time Utilities Utilities NS Entry Lobby 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W[amps &2L IOP-LP Utilities Utilities NB Entry Lobby 12 12 Retrofit fixture w/ (2) F32T8/ADVB41/EW/LUALTO 28W lamps & (112) 41 IOP-LP Utilities Utilities NB Entry Lobby 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 POP -LP Utilities Utilities NB Entry Lobby 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Deep Bell Utilities Utilities NB Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841AEW/LUALT0 28W lamps, 2L IOP Stntl, 2x4 Deep Refl Utilities Utilities NB Office 1 0 Sensor Spec WSIR Utilities Utilities NB Closet 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L IOP-LP Utilities Utilities NB Halls 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W [amps & 21 IOP-LP Utilities Utilities NB Halls 1 1 Install new Green LED Exit w/ Battery Back up Utilities Utilities NS Library 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUA1-TO 28W lamps, 21 IOP Sintl, 2x4 Deep Refl Utilities Utilities NB Library 1 0 Sensor Spec WSIR Utilities Utilities NB Phone Room 5 5 Retrofit fixture w/(2)F32T8/ADV8411EW/LUALTO 28W lamps. 21 ]OR Sind, 2x4 Deep Bell Utilities Utilities NB Stairs 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/L1JA1-T0 28W lamps, 21 IOP Sintl. 2x4 Deep Refl (I Utilities Utilities NB Stairs 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW)LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Conference Room 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/1-UALT0 28W lamps, 2L IOP Sind. 2x4 Deep Bell Utilities Utilities NB Conference Room 2 0 No Retrofit at this time Utilities Utilities NB Office 5 5 Retrofit fixture wl (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Stnd, 2x4 Deep Bee Utilities Utilities NB Office 1 0 Sensor Spec WSIR Utilities Utilities NB Office 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/L1JALT0 28W lamps, 21 POP Sind, 2x4 Deep Rea Utilities Utilities N6 Office 1 0 Sensor Spec WSIR Utilities Utilities NB Office 3 3 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps, 21 1OP She, 2x4 Deep Rea Utilities Utilities NB Office 1 0 Sensor Spec WSIR Utilities Utilities NB Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21. [OR Stnd, 2x4 Deep Rea Utilities Utilities NB Office 1 0 Sensor Spec VVSIR Utilities Utilities NB Locker 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/L1JALTO 28W lamps, 2L IOP Stnd, 2x4 Bell Utilities Utilities NS Mens RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21. IOP Sintl, delamped Utilities Utilities NB Mens RR 2 2 Install new 21 13W CF Drum Fixture Utilities Utilities NB Stairs 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Office 3 3 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Attachment #1 - City-wide Lighting Scope Utilities Utilities A/B Office 3 3 Retrofit fixture w/ (3) F32T8/ADV841IEW/LUALTO 28W lamps & 3L [OR LP Utilities Utilities ND Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Utilities Utilities AlB Office 4 4 Retrofit fixture w/(3)F32T8/ADV841/EW/LL/ALTO 28W lamps &3L IOP LP Utilities Utilities AIB Office 3 3 Retrofit fixture W/ (3) F32T8/ADV841/EWAL/ALTO 28W lamps & 31 OR LP Utilities Utilities A/B Office 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 31 IOP Utilities Utilities A/B Office 2 2 LP Retrofit fixture w/(3)F32TB/ADV841/EW/LUALTO 28W lamps &3L IOP LP Utilities Utilities A/B Records 7 7 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Utilities Utilities AID Custodian 1 1 Retrofit fixture W/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Utilities Utilities AB Sprinkler 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps 8, 2L IOP-LP Utilites Utilities A/B Corridor 7 7 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities A/B Open Office 8 8 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&(112)4L IOP-LP Utilities Utilities A/B Open Office 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Utilities Utilities A/B Office 320 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW(LUALTO 28W lamps, I & 2L IOP LP Utilities Utilities Ala Office 320 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W Iamps, 1L & 2L [OR LP Utilities Utilities A/B Office 320 1 0 Sensor Spec Utilities Utilities A/B Office 319 2 2 Retrofit fixture w/ (3) F32T6/ADV841/EW/LUALTO 28W lamps, I & 2L IOP LP WSIR-2P Utilities Utilities AlB Office 319 1 1 Retrofit fixture W/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, l L&2L IOP LP Utilities Utilities AID Office 2 2 Retrofit fixture W/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I & 21 IOP LP Utilities Utilities A/B Office 1 1 Retrofit fixture w/ (3) F32T8/ADV841IEW/LUALTO 28W lamps. I & 2L IOP LP Utilities Utilities A/B Office 1 0 Sensor Spec Utilities Utilities A/B Office 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP WSIR-2P Utilities Utilities AIB Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L & 21 IOP LP Utilities Utilities A/B Office 1 0 Sensor Spec Utilities Utilities A/B Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L & 2L IOP LP WSIR-2P Utilities Utilities A/B Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, l L&2L IOP LP Utilities Utilities NB Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W tamps, l L&2L IOP LP Utilities Utilities NB Office 1 1 Retrofit fixture W/ (3) F32T8/ADV841/EW/LUALTO 28W tamps, 1L & 21 OR LP Utilities Utilities AS Office 2 2 Retrofit fixture w/ (3) F32T8/ADV84VEW/LUALTO 28W lamps. I & 21 IOP LP Utilities Utilities A/B Office 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LLIALTO 28W lamps. i L&2L IOP LP Utilities Utilities A/B Office 2 2 Retrofit fixture w/(2)F32T8/ADV&41/EW/LVALTO 28W lamps, 2L IOP Stri 2x4 Deep Retl Utilities Utilities NB Office 1 0 Sensor Spec WSIR Utilities Utilifies A/S Corridor 10 0 No Retrofit at this time Utilities Utilities AIB Corridor 5 0 No Retrofit at this time Utilities Utilities A/B Entry 2 0 No Retrofit at this time Utilities Utilities A/B Entry 1 1 Replace Lamp w/23W Screw in CF Utilities Utilities NB Mena RR 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W tamps, 2L IOP Sind, & 2x4 Roll Utilities Utilities AID Mans RR 4 0 No Retrofit at this time Utilities Utilities A/B Mens RR 2 0 No Retrofit at this time Utilities Utlities A/B Mach Room 7 7 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28Wiamps&2L IOP-LP Utilities Utilities NB Mach Room 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALTO 28WIamps&2L IOP-LP Utilities Utilities AIB Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Stud, 2x4 Deep ReFl Utilities Utilities NB Conference 4 4 Retrofit fixture w/ (2) F32T8/ADV&41/EW/LUALTO 28W lamps. 21 IOP Stine, 2x4 Deep Refi Utilities Utilities A/B Conference 1 0 Sensor Spec WSIR Utilities Utilities A/B Copy 5 5 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP Stnd. 2x4 Deep Ral Utilities Utilities AID Copy 1 0 Sensor Spec CIR Utilities Utilities A/B Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Utilities Utilities A/S Office 4 4 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Attachment #1 - City-wide Lighting Scope Utilities Utilities NB Corridor 3 0 NO Retrofit at this time aensori Utilities Utilities NB Halls 5 5 Retrofit fixture w/(1)F32T8/ADV84VEW/LUALTO 28W lamps &iL IOP-LP Utilities Utilities NB Office 2 2 Retrofit fixture w/(3)F32T8/ADV84VEW/LUALTO 28Wlamps, i L&2L IOP LP Utilities Utilities NB Office 1 0 Sensor Spec Utilities Utilities NB Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LL/ALTO 28W lamps, l L&2L WSIR-2P Utilities Utilities NB Office 1 0 IOP LP Sensor Spec Utilities Utilities NB Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps, 1L & 2L IOP LP WSIR-2P Utilities Utilities NB Office 1 0 Sensor Spec Utilities Utilities NS Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, l L&2L IOP LP WSIR-2P Utilities Utilities NB Office 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1 L & 21 Utilities Utilities NB Office 1 0 IOP LP Sensor Spec Utilities Utilities NB Office 4 4 Retrofit fixture w/ (3) F32T8/ADV84VEW/LUALTO 28W lamps, I & 2L IOP LP WSIR-2P Utilities Utilities NB Office 1 0 Sensor Spec WSIR-2P Utilities UBlities NB Once 4 4 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, l L& 2L IOP Utilities Utilities NB Office 1 0 LP Sensor Spec Utilities Utilities NS Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps, 1L & 2L IOP LP WSIR-2P Utilities Utilities NB Office 2 2 Retrofit fixture w/(3)F32T8/ADV84VEW/LUALTO 28W lamps. i L&2L IOP LP Utilities Utilities NB Office 1 0 Sensor Spec Utilities Utilities NB Office 2 2 Retrofit fixture w/(3)F32T8/ADVB41/EW/LUALTO 28W lamps, 1 L&2L IOP LP WSIR-2P Utilities Utilities NB Office 1 0 Sensor Spec Utilities Utilities NB Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps. I & 2L IOP LP WSIR-2P Utilities Utilities NB Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, i L&2L IOP LP Utilities Utilities NB Office 2 2 Retrofit Winne w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, lL&2L IOP LP Utilities Utilities NB Office 2 2 Retrofit Wore w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, l L&2L IOP LP Utilities Utilities NB Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L & 21 IOP LP Utilities Utilities NB Office 1 0 Sensor Spec WSIR-2P Utilities Utilities NB Halls 7 7 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Halls 1 1 Install new Green LED Exit w/ Battery Back up Utilities Utilities NB Worriers Locker 4 0 No Retrofit at this time Utilities Utilities NB Worsens Locker 1 0 No Retrofit at this time Utilities Utilities NS Womens Locker 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Office 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Utilities Utilities NB Halls 3 3 Deep Refi Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Halls 2 2 Install new Green LED Exit w/ Battery Back up Utilities Utilities NB Exercise Room 8 8 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps, 1L & 2L IOP LP Utilities Utilities NB Exercise Room 1 1 Retrofit fixture w/ (3) F32T8/ADV8411EW/LUALTO 28W lamps, 1L & 2LIOP LP Utilities Utilities NS Exercise Room 6 6 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Exercise Room 1 0 Sensor Spec CDT1500 Utilities Utilities NB Understair storage 1 1 Replace Lamp W 23W Screw in CF Utilities Utilities NB Stairs 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stnd, & 8' Socket Plat Utilities Utilities NS Mech Room 8 B Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Utilities Utilities NB Mech Room 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28Wiamps&2L IOP-LP Utilities Utilities NB Office 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Mach Room 1 1 Replace Lamp w/ 23W Screw in CF Utilities Utilities NB Lamp Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W Iamps & (1/2) 4L IOP-LP Utilities Utilities NB Lamp Storage 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities NB Lamp Storage 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28Wiamps a 2L IOP-LP Attachment #1 - City-wide Lighting Scope afouP ane name Area Uescnpnon Fixts Exist Fixts Proposed Retrofit Description Sens< Utilities Utilities A/B Lamp Storage 8 8 Retrofit fixture w/ (2) F32T8/ADV841IEW/LUALT0 28W lamps & 21 IOP-LP Utilities Utilities A/B Halls 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Conference 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Ref Utilities Utilities A/B Conference 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, &2x4 Red Utilities Utilities A/B Conference 1 0 Sensor Spec WSIR Utilities Utilities A/B Nurse Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 21. IOP-LP Utilities Utilities AID Nurse Office 2 2 Retrofilfixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sims, 2x4 Rell Utilities Utilities A/B Nurse Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Sind, 2x4 Refi Utilities Utilities A/B Office 1 0 Sensor Spec CIR Utilities Utilities AS Office 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Womens RR 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALTO 28Wiamps&2L IOP-LP Utilities Utilities A/8 Womens RR 1 0 Sensor Spec WSIR Utilities Utilities A/B Storage 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Conference 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 21 IOP-LP Utilities Utilities A/B Office 4 4 Retrofit fixture w/(2)F32T8/ADV84VEW/LL/ALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Corridor 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Utilities Utilities A/S Office 1 0 Sensor Spec WSIR Utilities Utilities AB Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841IEW/LUALT0 28W lamps & 21 IOP-LP Utilities Utilities A/B Office 1 0 Sensor -Spec WSIR Utilities Utilities A/B Office 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/L/ALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Computer 4 4 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, I IOP LP, &2L IOP LP(Dua Utilities Utilities A/8 Computer 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/8 Corridor 1 0 No Retrofit at this time ' Utilities Utilities AIR Mens RR 1 1 Retrofit fixture w/ (2) F32T8/ADV84VEW/1-UALTO 28W lamps & 21 IOP-LP Utilities Utilities A/B Mens RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W Iamps & (1/2) 41 IOP-LP Utilities Utilities A/B Mens RR 1 1 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps & (112) 4L lOP-LP Sitar Utilities Utilities A/B Corridor 8 0 No Retrofit at this time Utilities Utilities A/B Corridor 2 0 No Retrofit at this time Utilities Utilities A/B Corridor 2 0 No Retrofit at this time Utilities Utilities Aid Corridor 5 0 No Retrofit at this time Utilities Utilities A/S Corridor 2 0 No Retrofit at this time Utilities Utilities A/B Office 3 3 Retrofit future w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 21 IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities AIR Office 3 3 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Conference 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1 L IOP LP, & 21 IOP LP (Due Attachment #1 - City-wide Lighting Scope up one name Area uescnpnon fiats Exist Pixts Proposer! Retrofit Description Sensor Type Utilities Utilities A/B Office 4 4 Retrofit fixture w/(2)F32T8/ADV8411EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities AID Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 3 3 Retrofit fixture w/(2)F32T8/AOV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities A/B Office 1 0 Sensor Spec WSIR Utilities Utilities A/B Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW1LUALTO 28W lamps & 2L IOP-LP Utilities Utilities A/B Office 26 26 Retrofit fixture w/ (2) F32T&ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities A/B Electrical UPS 1 1 Retrofit fixture w/(2)F32T8/ADVW1EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities A/B Record Storage 14 14 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28Wiamps&2L IOP-LP Utilities Utilities A/B Cafeteria/Break 16 0 No Retrofit at this time Utilities Utilities A/B Mens RR 4 4 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps &1L IOP-LP Utilities Utilities A/B Mans Locker 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities A/B Womens RR 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities A/B Womens RR 1 0 No Retrofit at this time Utilities Utilities A/B Corridor 3 0 No Retrofit at this time Utilities Utilities A/B Corridor 2 0 No Retrofit at this time Utilities Utilities AS Corridor 2 0 No Retrofit at this time Utilities Utilities A/B Vending 1 0 Sensor Spec VEND MISER - Utilities Utilities A/B Vending 1 0 Sensor Spec VEND MISER - Utilities U6lifies C Garage 18 18 Retrofit fixture w/ (4) F32T8/ADV841/EW&UALTO 28W lamps, 4L IOP LP, & 8' Hooded Intl C Utilities Utilities C Garage 2 2 Install new Green LED Exit w/ Battery Back up Utilities Utilities C Locker Room 6 6 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP, & e' Hooded Ind C Utilities Utilities C Break Room 7 7 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Utilities Utilities C Break Room 2 2 Install new Green LED Exit w/ Battery Back up Utilities Utilities C Break Room 4 4 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Utilities Utilities RR 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Utilities Utilities C RR 2 2 Retrofit fixture w/ (4) F32T8/ADV8411EW/LUALTO 28W lamps, 4L IOP LP Utilities Utilities C Custodian 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities C Storage Garage 3 3 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP, & 8' Hooded Intl C Utilities Utilities C Break Room 1 0 Sensor Spec VEND MISER - Utilities Utilities Meter Shop Vestibule 1 0 No Retrofit at this time Utilities Utilities Meter Shop Vestibule 1 0 No Retrofit at this time Utilities Utilities Meter Shop Open Office 28 0 No Retrofit at this time Utilities Utilities Meter Shop Office 6 0 No Retrofit at this time Utilities Utilities Meter Shop Conference 8 0 No Retrofit at this time Utilities Utilities Meter Shop Conference 3 0 No Retrofit at Mis time Utilities Utilities Meter Shop Conference 1 0 Sensor Spec CIR Utilities Utilities Meter Shop Womens RR 5 0 No Retrofit at this time Utilities Utilities Meter Shop Womens RR 1 0 No Retrofit at this time Utilities Utilities Meter Shop Womens RR 1 1 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities Meter Shop Womens RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities Meter Shop Womens RR 1 0 Sensor Spec WSUS Utilities Utilities Meter Shop Mena RR 5 0 No Retrofit at this time Attachment 91 - City-wide Liqhtina Scooe Group Site Name Area Description Fists Exist Fixs Proposed Retrofit Description Sensor Type Sensor Qty Utilities Utilities Meter Shop Mans RR 1 0 No Retrofit at this time Utilities Utilities Meter Shop Mans RR 2 2 Retrofit Ward w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities Meter Shop Mans RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities Meter Shop Men$ RR 1 0 Sensor Spec WSUS 7 Utilities Utilities Meter Shop Corridor 6 6 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Utilities Utilities Meter Shop Corridor 1 0 No Retrofit at this time Utilities Utilities Meter Shop Conference 7 7 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Utilities Utilities Meter Shop Prep 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L I0P LP Utilities Utilities Meter Shop File 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L Go LP Utilities Utilities Meter Shop Janitor 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Utilities Utilities Meter Shop Electrical 2 2 Retrofit fisture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities Meter Shop Mechanical 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Utilities Utilities Meter Shop Meter Test 21 21 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP, & B' Hooded Intl C Utilities Utilities Meter Shop Meter Test 2 0 No Retrofit at this time Utilities Utilities Meter Shop Staging 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities Meter Shop Electronics 4 4 Retrofit marine w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP, & 8' Hooded Ind C Utilities Utilities Meter Shop Electronics 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Utilities Utilities Meter Shop Assembly 2 2 Retrofit fixture wl (4) F32T8/ADV841/EW/LL/ALTO 28W lamps, 4L IOP LP, & 8' Hootletl Ind C Utilities Utilities Meter Shop Work 4 4 Retrofit fixture wl (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP, & 8' Hooded Ind C Utilities Utilities Meter Shop Tool 3 3 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALT028W lamps &2L IOP-LP Utilities Utilities Meter Shop Compressor 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities Vehicle St., Vehicle Storage 28 28 Retrofit fixture W (4) F32TB/ADV841/EW/LUALTO 28W lamps, 4L IOP Sim. & 8' Industrial H, Utilities Utilities Vehicle Star Vehicle Storage 6 6 Retrofit fixture w/ (4) F32T8/ADV8411EWILUALTO 28W lamps, 4L IOP LP, & B' Hooded Ind C Utilities Utilities Vehicle Stor Tool Storage 10 10 Retrofit fixture w/ (4) F32T8/ADV841/EW/WALTO 28W lamps, 4L IOP Slnd, & S Industrial H, Utilities Utilities Vehicle Star Tool Storage 6 6 Retrofit fixture w/ (4) F32T8/ADV8411EW/LUALT0 28W lamps, 4L IOP-LP, & 8' Industrial He Utilities Utilities Vehicle Stor Vehicle Storage 2 0 No Retrofit at this time Utilities Utilities Vehicle Stor Tool Storage 10 10 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALT028W lamps, 4L IOP-UP, & 8'lndustrial He Utilities Utilities Vehicle St., Womens RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities Vehicle Shot Mans RR i i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Utilities Utilities Vehicle St., Exterior 10 0 No Retrofit at this time Utilities Utilities Vehicle Star Exterior 2 0 No Retrofit at this time Totals 9967 6612 486 Ballasts that contain PCB's must be sent for incineration at a TSCA approved facility. Mercury containing lamps and non-pcb ballasts must be sent to an approved resource recovery facility for recycling. Disposal facilities must be approved by a City of Fort Collins Environmental Regulatory Specialist prior to disposal. Attachment # 2 Lincoln Center Redesign Lincoln Center Our team followed the project design that was submitted by David Nelson. We believe that his design addresses both lighting and energy issues. He is replacing most of the incandescent fixtures with new compact fluorescent recessed fixtures. This will improve the lighting in the hallway/ gallery areas and lower energy usage. We also believe that it is better to replace the track lighting with new track and new track heads. By using a combination of compact fluorescent and MR16 halogen track heads, you improve the energy efficiency and still allow the flexibility for the proper display of the various types of art work. The only changes that we made for this project were to use less expensive brands of fixtures than what David Nelson specified. We have substituted Nora Lighting recessed fixtures for the Lithonia and WAC Lighting track and track heads for the LSI. We selected fixtures that have very similar specs to the fixtures that David Nelson specified. We also substituted Sensor Switch controls for the Watt Stopper. All of these changes should have lowered the pricing without sacrificing either the design or the performance. FixtQty retroDescr Unit Charge Project Charge 37 NHP81J-226/NTS-872WLISF $369,10 $13,656.88 32 NHP8U-126/NTS-879LIWFDC-WH $392.09 $12,546.97 2 HHT-819-WT MR16 head w/ HMP-WT monopoint & lamp $253.59 $507.18 14 101-32XV 1-L T8 strip $129.75 $1,816.51 1 Track parts - 200' & all parts $i 929 23 $1,929.23 50 HHT-819-WT MR16 head w/lamp $20872 $10.436.25 60 HTK-W126E-HS-WTw/L126-WT louver &lamp $301,01 $18,060,34 1 Sensor Switch Custom Lighting Control system (includes- Data line wall switch; open loop multi zone control module, low voltage relay panel, network time Clock, Factory commissioning.service $4,138.56 $4,138.56 Attachment # 3 Mulberry Pool lighting Redesign At Mulberry Poo, we are specifying T8 fixtures not T5HO with the following specifications. • Wet location powder coat painted aluminum body fixtures not open steel fixtures • T'8 fixtures will use the same T8 lamps as in the rest of the building • T8 fixtures are less expensive to maintain — T8 lamps and ballasts are less expensive than T5HO • The T8 system is more reliable with less problems than the T5HO system • Our design saves 21% more energy than the other design without sacrifice light levels Following is the analysis we performed as part of this redesign effort. Energy analysis Type PI —existing 34 ea. 400 watt metal halide highbays @460 watts 15,640 watts Nelson's design 34 ea. 6-L T5HO highbay — direct @362 watts 12,308 watts WSI's design 30 ca. 8-L T8 wet location highbay— direct* @288 watts 8,760 watts Type P2 — existing 48 ea. 400 watt metal halide indirect @460 watts 22,080 watts Nelson's design 48 ea. 2-L T5HO industrial strip — indirect @121 watts 5,808 watts WSI's design 24 ea. 6-L T8 wet location highbay — indirect @222 watts 5,328 watts Nelson's design saves — 19,604 watts WSI's design saves— 23,752 watts Performance analysis 6-L T5HO 4,500 lumens X 6 X 1.0 BF = 27,000 lumens 8-L T8 2,950 lumens X 8 X 1.15 BF = 27,140 lumens Twin 2-L T5HO 4,500 lumens X 2 X 1.0 BF = 9,000 lumens X 2 = 18,000 lumens 6-L T8 2,950 lumens X 6 X 1.18 BF = 20,886 lumens *We are eliminating one of the double fixtures that are at each corner of the building because we fell that they are unnecessary after the lighting upgrade. This is why our total for Type PI is only 30 fixtures. POWER OF ATTORNEY KNOW ALL BY THESE PRESENTS: No. 10618 Safeco Insurance Company of America General Insurance Company of America Safeco Plaza Seattle, WA 98185 That SAFECO INSURANCE COMPANY OF AMERICA and GENERAL INSURANCE COMPANY OF AMERICA, each Washington corporation, does each hereby appoint *"**"**********KATHLEEN A. CRARY; LUCY A, HANTZSCH; CATHY HUTSON; DANIEL J. KWIECINSKI; TRACY K. MATTHEWS; WENDY S. MILLER; DANIEL J. SAPIRO; LISA M. SLAKES; Milwaukee, Wisconsin*************************"***************** its true and lawful attorneys) -in -fact, with full authority to execute on its behalf fidelity and surety bonds or undertakings and other documents of a similar character issued in the course of its business, and to bind the respective company thereby. IN WITNESS WHEREOF, SAFECO INSURANCE COMPANY OF AMERICA and GENERAL INSURANCE COMPANY OF AMERICA have each executed and attested these presents this 22nd day of January 2008 STEPHANIE DALEY--WATSON SECRETARY TIM MIKOLAJEWSKI SENIOR VICE-PRESIDENT SURETY CERTIFICATE Extract from the By -Laws of SAFECO INSURANCE COMPANY OF AMERICA and of GENERAL INSURANCE COMPANY OF AMERICA: "Article V, Section 13. - FIDELITY AND SURETY BONDS... the President, any Vice President, the Secretary, and any Assistant Vice President appointed for that purpose by the officer in charge of surety operations, shall each have authority to appoint individuals as attorneys -in -fact or under other appropriate titles with authority to execute on behalf of the company fidelity and surety bonds and other documents of similar character issued by the company in the course of its business... On any instrument making or evidencing such appointment, the signatures may be affixed by facsimile. On any instrument conferring such authority or on any bond or undertaking of the company, the seal, or a facsimile thereof, may be impressed or affixed or in any other manner reproduced; provided, however, that the seal shall not be necessary to the validity of any such instrument or undertaking." Extract from a Resolution of the Board of Directors of SAFECO INSURANCE COMPANY OF AMERICA and of GENERAL INSURANCE COMPANY OF AMERICA adopted July 28, 1970. "On any certificate executed by the Secretary or an assistant secretary of the Company setting out, (1) The provisions of Article V, Section 13 of the By -Laws, and (ii) A copy of the power -of -attorney appointment, executed pursuant thereto, and (iii) Certifying that said power -of -attorney appointment is in full force and effect, the signature of the certifying officer may be by facsimile, and the seal of the Company may be a facsimile thereof." I, Stephanie Daley -Watson , Secretary of SAFECO INSURANCE COMPANY OF AMERICA and of GENERAL INSURANCE COMPANY OF AMERICA, do hereby certify that the foregoing extracts of the By -Laws and of a Resolution of the Board of Directors of these corporations, and of a Power of Attorney issued pursuant thereto, are true and correct, and that both the By -Laws, the Resolution and the Power of Attorney are still in full force and effect. IN WITNESS WHEREOF, I have hereunto set my hand and affixed the facsimile = np seal of said corporation '} this ' day of : A4 4.00 r . pHGE COAga9y` �NgECOMPq VT CORPORATE SEAL SEAL air l s AS I WASNt2� FOf MI�'' ���aWdS��\S $TEPHANIE DALEY-WATSON, SECRETARY `. Safri and the$afece logo are registered trademarks of Safeco Corporation. S-0974/DS 4/05 WEB PDF Attachment # 4 Scope 215 North Mason Street Facility Following is the scope of work for retrofit of the lighting systems at 215 North Mason Street facility. 215 North Mason • Existing 7 Series T8 Lamps & Electronic Ballast • Existing 42W Compact Fluorescent lamps • We propose retrofitting existing 4' T8 fixtures with Energy Saving 4th generation 28W T8 lamps & 3rd Generation High Efficiency Electronic Ballast • We proposed to relamp 2' & 3' T8 lamps with 8 series 2' & 3' T8 Lamps • We proposed to relamp existing 42W Compact Fluorescent Lamps Following is the specific list of energy saved, rebates and payback. • Estimated Total KW Saved 18 • Estimated Total KWH Saved 69,968 • Estimated Annual Value of Energy Saved $5,004.53 • Estimated Rebate $7,911.00 • Estimated Annual Maintenance Avoidance $936.88 • Estimated Payback 6.22 Yrs Attachment #5 - Estimated Project Savings Johnson Controls City of Fort Collins Lighting Retrofit Savings Proposal Summary November 14, 2007 Fixture Summary Total Site Fixture Qty 11,197 Fixture Qty to be Retrofit or Replaced 7,842 Energy Savings Existing KW of Fixts to be Retrofit or Replaced 1 232 Proposed KW of Fixts to be Retrofit �or Re laced 869 Projected Total KW Savings 363 Projected Total Annual KWH Savings 1,255,818 Projected Annual Energy Cost Savin s $ g3,455.48 HVAC Interactive Projective Savings $ (5,607.33) Net Projected Annual Energy Cost Savings $ 87 g48.15 Installation Cost & Utility Incentives Projected Utility Incentive (PRPA) $ 163,325.25 Controls Summary Controls Installed 496 Energy Savings Estimated KWH Saved 136,631 Projected Annual Energy Cost Savin s $ 10,255.83 Installation Cost & Utility Incentives Projected Sensor Utility Incentive (PRPA) $ 6,724.00 Project Summary Energy Savings $ 98,103.98 Maintenance Savings $ 21,764.02 Total Savings $ 119,868.00 Energy Incentives' ($ 170,049.25 ✓elvanuem un rrrrH avowing rort coons rebate In excess of $'70q 000 cap Project Summary - City of Fort Collins tI 125aavi' Ir.armism Mon&1a1o6 23 1day Tue2 136 Tuo 2/2610B Iday wed v2Y.•a8 wca2 710e < <daYs. Thu 2/28N8 ._.. .. Tue 3/4I08 ---- ...._5 r 30 days wod 315/OB Tue 411&08 5days WM 4116MS Tue 4/ 108 ] 21 Jays' Wed 4123/06... Wood 5/21/08 ._._. __.. 8 95 days Mon&24ID8 Fri a11ro6.... "3 4daYs" Mon 3n4N0 4hv V27108 10 4aaya. For WBOB Wed 4zo8 it 7do, Thu 4/Y08 Fr 4/1'NB i2 tday Mon 4114108 Non 4/14asy 13 9a., 'Tue 4i15ro8 Fri m25/08 14— 2days MOn a28/O6 - Tue 429/OB 2days' Wed r1OXB..... IN 511/0e 16 -1ad, Fir 5/ 8 Fn5 08 -" T] 1day Mon Y5/C3 Man 515108 tBy 1day. Toe S/605 Tue W108 19 l 1day Wed S/1/D8 Wed S/iNe 20 ' 3days Thu 51&08 Mon 511ne 2] 9do, Tue S/13N0 Fn NWos 22 3us, h1on 52d1 Wed S2&0B 23 3or, Thug SM Man 6R= 2a ;days Toe 6/3108 Wed Fri if, 25 In days' Thu WIMM N/ed 625108 26 - - 8days Thu V26108 Mpdi/i108 27 1 day Tuc ]/&CB Tve 7l8IOB 28 1do, on 7sn6 WM]9/Ce 6anus Thu]noro0 Thu]/1T/08 20 64ays' Fri]/16N6 Fr 725IOB 31 5an, bun 7nWe Fri 6/1N6 32 Sun, Mon 7/28108 Fri 811108 33 2days Man]/2&08 --Tue]29n10 34 3day5. Wed]/3OX8 Fri e11/08 35 � 20 days A1on 619NeR1 7/4/00 W 18 days Iran 6l91De Non 6130108 37 1d., Tue]/1/CB Tue]/1109 38 1day. Wed 2206 Wed 917/08 39 2days Thu]/3/p5 Fri ToAOB 4p 21 days on 7121108 Mon.118109 Gi 6aays Mon 72IM Mon 7128108 21 days Mon 71.i108 Mon&18108 43 6days Mon&4/DB Non&11/OB j 44 2days TUC&12/o8 VJed eIIWOB 45 3ari, 7r,&140B so, 8l18N8 a6 4days Tue a/19g8 Fri 82Y08 2/26 O M6 212T O27 L2o O 314 315 - City of Ft. Collins Project Schedule darn O M22 .3 zt 3124 © 3.1 3128 = de 413 4111 - N14 O 41t4 41150 W26 42a [3 4129 '30 0 &1 512 0 5I2 5'5 0 Y5 .0516 wOS e = 5112 SI13 S/23 5126 ❑ 5I28 5129 = se 613 0 6111 .12 r J 6126 mo O ]O ]Rp]18 ]/9 p T9 7/10 O ]I1] ]/18 F Wmmmmmmmmmmv 619 6p0 TIT 711 ]2 O ]I2 ➢3 0 T/4 J ]/25 ]/28 O &1 WmW ]/29 ❑ ]/M ]I30El 8I1 7121 O T/28 ]/21 &10 &4 Hari &12 ❑ 8113 $114 O &18 &19 F7 BI22 Project Ft Coffins G9hting BCF.edulet Task 0 lliiles:one ♦ ROIkd Up ask RORM Up Pro9mss Etlernal asks _ Group Bl Summary pale. or 2/i t/OB P,,ro. summary ^ RMIdUp NAeSIodo 6qR P,-tsn—•Tary Deatl nC �j Page i SECTION 00530 NOTICE TO PROCEED Description of Work: City of Fort Collins Lighting and Retrofit Project To: This notice is to advise you: That the contract covering the above described Work has been fully executed by the CONTRACTOR and the OWNER. That the required CONTRACTOR's Performance Bond and Payment Bond have been received by the OWNER. That the OWNER has approved the said Contract Documents. Therefore, as the CONTRACTOR for the above described Work, you are hereby authorized and directed to proceed within (_) calendar days from receipt of this notice as required by the Agreement. Dated this day of , 20 The dates for Substantial Completion and Final Acceptance shall be 20_ and 20_, respectively. City of Fort Collins OWNER Title: ACKNOWLEDGMENT OF NOTICE Receipt of the above Notice to Proceed is hereby acknowledged this day of , 20 CONTRACTOR: Johnson Controls, Inc. By: Title: 7/96 Section 00530 Page 1 SECTION 00610 PERFORMANCE BOND Bond No.6554825 REISSUE KNOW ALL MEN BY THESE PRESENTS: that Johnson Controls, Inc. (Firm) 5757 North Green Bay Avenue (Address) Milwaukee, WI 53209 (&R'KxX�XbOx9ZX�9Wtz�k) , (axxRaxxx�cx�bp) , (a Corporation) , hereinafter referred to as the "Principal" and Safeco Insurance Company of America (Firm) Safeco Plaza (Address) Seattle, WA98185 hereinafter referred to as "the Surety", are held and firmly bound unto City of Fort Collins, 300 LaXJorte Ave, Fort _Collins, Colorado 80522 a (Municipal Corporation) hereinafter referred to as the "OWNER", in the penal sum of One Million Fourteen Thousand Four Hundred * in lawful money of the United States, for the payment of which sum well and truly to be made, we bind ourselves, successors and assigns, jointly and severally, firmly by these presents. THE CONDITIONS OF THIS OBLIGATION are such that whereas the Principal entered into a certain Agreement with the OWNER, dated the 5th day of MaV , 2008, a copy of which is hereto attached and made a part hereof for the performance of The City of Fort Collins Lighting and Retrofit Project. NOW, THEREFORE, if the Principal shall well, truly and faithfully perform its duties, all the undertakings, covenants, terms, conditions and agreements of said Agreement during the original term thereof, and any extensions thereof which may be granted by the OWNER, with or without Notice to the Surety and during the life of the guaranty period, and if the Principal shall satisfy all claims and demands incurred under such Agreement, and shall fully indemnify and save harmless the OWNER from all cost and damages which it may suffer by reason of failure to do so, and shall reimburse and repay the OWNER all outlay and expense which the OWNER may incur in making good any default then this obligation shall be void; otherwise to remain in full force and effect. *Thirteen Dollars and 001100 ($1,014,413.00) 7/96 Section 00610 Page 1 BOND NUMBER: 6554825 REISSUE PROVIDED, FURTHER, that the said Surety, for value received, hereby stipulates and agrees that no change, extension of time, alteration or addition. to the terms of the Agreement or to the Work to be performed thereunder or the Specifications accompanying the same shall in any way affect its obligation on this bond; and it does hereby waive notice of any such change, extension of time, alteration or addition to the terms of the Agreement or to the Work or to the Specifications. PROVIDED, FURTHER., that no final settlement between the. OWNER and the CONTRACTOR shall abridge the right of any beneficiary hereunder, whose claim may be unsatisfied. PROVIDED, FURTHER, that the Surety Company must be authorized to transact business in the State of Colorado and be acceptable to the OWNER. IN WITNESS WHEREOF, this instrument is executed in four (4) counterparts, each one of which shall. be deemed an original., this 12th day"of May, 20 08. IN PRESENCE OF: Principal JOHNSON CONTROLS INC.. Catherine B. Hutson; Attorney -In -Fact (Title) 5757 North Green Bay Avenue, Milwaukee WI 53209 (Address) (Corporate Seal) IN PRESENCE OF: Other Partners Bv: By: IN PRESENCE OF: e / Surety Safeco Insurance Company of America BY Tracy K. Matthews; Attorney- In•Fact By: Safeco Plaza: Seattle WA 98185 � (Address) (Surety Seal) NOTE: Date of Bond must not be prior to, date of Agreement. If CONTRACTOR is Partnership; all. .partners should execute Bond. 7/96 Section 00610 Page 2 SECTION 00615 PAYMENT BOND Bond No.6554825 REISSUE KNOW ALL MEN BY THESE PRESENTS: that Johnson Controls, Inc. (Firm) 5757 North Green Bay Avenue (Address) Milwaukee, WI53209 (mxxx)Z>Z 'J<RX Awk) , (xxxxkAVMRx ) , (a Corporation) , referred to as the "Principal" and Safeco Insurance Company of America (Firm) Safeco Plaza (Address) Seattle, WA 98185 hereinafter referred to as "the Surety" are unto the CiT.y of Fort Collins, 300 Laportt Colorado 80522 a (Municipal Corporation) hereinafter referred to as "the OWNER", in the penal sum of in lawful. money of the United States, for the payment of which sum well and truly to be made, we bind ourselves, successors and assigns, jointly and severally, firmly by these presents. hereinafter held and firmly bound Ave., Fort Collins, THE CONDITIONS OF THIS OBLIGATION are such that whereas the Principal entered into a certain Agreement with the OWNER, dated the 5th , day of May , 2008, a copy of which is hereto attached and made a part hereof for the performance of The City of Fort Collins project, City of. Fort Collins Li-gh.ti.ng and Retrofit Project. NOW, THEREFORE, if the Principal shall make payment to all persons, firms, subcontractors, and corporations furnishing materials for or performing labor- in the prosecution of the Work provided for in such Agreement and any authorized extension or modification thereof, including all amounts due for materials, lubri-cants, repairs on machinery, equipment and tools, consumed, rented or used in connection with the construction of, such Work, and all insurance premiums on said Work, and for all labor, performed in such Work whether by subcontractor or otherwise, then this obligation shall be void; otherwise to remain in full force and effect - *One Million Fourteen Thousand Four Hundred Thirteen Dollars and 00/100 ($1,014,413.00) 7/96 Section 00615 Page I BOND NUMBER: 6554825 REISSUE PROVIDED, FURTHER, that the said Surety, for value received, hereby stipulates and agrees that no change, extension of time, alteration or addition to the terms of the Agreement or to the Work to be performed thereunder or the Specifications accompanying the same shall in any way affect its obligation on this bond; and it does hereby waive notice of any such change, extension of time, alteration or addition to the terms of the Agreement or to the Work or to the Specifications. PROVIDED, FURTHER, that no final settlement between the OWNER and the CONTRACTOR shall abridge the right of any beneficiary hereunder, whose claim may be unsatisfied. PROVIDED, FURTHER, that the Surety Company must be authorized to transact business in the State of Colorado and be acceptable to the OWNER. IN WITNESS WHEREOF, this instrument is executed in four (4) counterparts, each one of which shall be deemed an original, this 12th day of May 2008• c IN PRESENCE OF: �— Princc//�,ppe�al JOHNSON CONT OLS, INC. By 44— eY 1 Catherine B. Hutson Attorney -In -Fact (Title) 5 5757 North Green Bay Avenue Milwaukee WI 53209 (Address) (Corporate Seal) IN PRESENCE OF: Other Partners IN PRESENCE OF: Surety SAFECO INSURNACE COMPANY OF AMERICA - k. - v � Tracy K. Matthews; Attorney--lnFdct L'�--',/ By: Safeco Plaza; Seattle WA 98185 v (Address) (Surety"Seal) NOTE: Date of Bond must not be prior to date, of Agreement. If CONTRACTOR is Partnership, all :partners should execute Bond. It 7/96 Section 00615 Page 2 Johnson Consols, Inc. 5757 N. Graer1 131,y Avenue Post Office Box 591 Milwaukee, Wl 5iVO1 W)91 l01,414/524 1200 f IHNS N DELEGATION OF AUTHORITY CONJ LS The undersigned, President of Johnson Controls, luc., a Wisconsin corporation (the "Company"), pursuant to the authority vested in him by a certain resolution adopted by the Board of Directors of the Company on .lanuary 23, 1980, hereby authorizes: Catherine 13. Hutson Hays Companies 1200 N. Mayfair Road, Suite 100 Milwaukee, W153226 to perform, on behalf of the Company, the acts described below: To execute, seal and deliver, as attorney -in -fact for the Company, surety bonds forwarded to Hays Companies by a Company authorized surety that do not exceed Two Million Dollars ($2,000,000.00) that arc necessary and proper in carrying ou the business of the Company. This authority shall remain in full force and effect for six (6) months from the date of issue. Signed at Milwaukee, Wisconsin, this I2�_ clay of'2,00�_._.. i KeitllJ.. Wandell. President Article 4. Intentonally Omitted Article 5. COST OF THE WORK 5.01 Cost of the Work shall be determined as provided in paragraphs 10.0LA and B of the General Conditions, but, in addition to any limitations therein set forth, it shall not include costs in excess of any Guaranteed Maximum Contract Price as set forth in Article 7 hereof. Article 6. Intentionally Omitted Article 7. GUARANTEED MAXIMUM PRICE 7.01 DESIGN/BUILDER guarantees that the maximum obligation of OWNER for the sum of the Cost of the Work plus the DESIGN/BUILDER'S Fee will not exceed $ One Million Fourteen Thousand Four Hundred Thirteen Dollars, ($1,014,413.00), the Guaranteed Maximum Price ("GMP") subject to increases or decreases for changes in the Work. Article 8. CHANGES IN THE WORK 8.01 The amount of any increases or decreases in the DESIGN/BUILDER's Fee or in any GMP or Fee which results from a Change Order shall be set forth in the applicable Change Order subject to the following: A. Any increase or decrease in the DESIGN/BUILDER's Fee resulting from net additions or decreases in the Cost of the Work shall be determined in accordance with paragraph 11.0 LC of the General Conditions. B. In the case of net additions or deletions in the Work, the amount of any increase or decrease in the GMP shall be determined in accordance with paragraph 10.01 of the General Conditions. Article 9. PAYMENT PROCEDURES 9.01 DESIGN/BUILDER shall submit and OWNER will process Applications for Payment in accordance with Article 13 of the General Conditions. Applications for Payment will indicate the amount of the DESIGN/BUILDER's Fee then payable. A. Progress Payments; Retainage. OWNER shall make progress payments on account of the Contract Price on the basis of DESIGNBUILDER's Applications for Payment, on or about the 15th day of each month during performance of the Work as provided in paragraphs 9.0l.A.1 and A.2 below. All such payments will be subject to the limitations of any GMP or DESIGN/BUILDER's Fee and will be measured by the POWER t 4 OF ATTORNEY KNOW ALL BY THESE PRESENTS: Safeco Insurance Company of America General Insurance Company of America Safeco Plaza Seattle, WA 98185 That SAFECO INSURANCE COMPANY OF AMERICA and GENERAL INSURANCE COMPANY OF AMERICA, each Washington corporation, does each hereby appoint -""***********KATHLEEN A. CRARY; LUCY A. HANTZSCH; CATHY HUTSON; DANIEL J. KWIECINSKI; TRACY K. MATTHEWS; WENDY S, MILLER; DANIEL J. SAPIRO; LISA M. SLAKES; Milwaukee, Wisconsin*****************************"************* its true and lawful attorney(s)-in-fact, with full authority to execute on its behalf fidelity and surety bonds or undertakings and other documents of a similar character issued in the course of its business, and to bind the respective company thereby. IN WITNESS WHEREOF, SAFECO INSURANCE COMPANY OF AMERICA and GENERAL INSURANCE COMPANY OF AMERICA have each executed and attested these presents this 22nd day of January 2008 STEPHANIE DALEY•WATSON SECRETARY TIM MIKOLAJEWSKI SENIOR VICE-PRESIDENT SURETY CERTIFICATE Extract from the By -Laws of SAFECO INSURANCE COMPANY OF AMERICA and of GENERAL INSURANCE COMPANY OF AMERICA: "Article V, Section 13. - FIDELITY AND SURETY BONDS ... the President, any Vice President, the Secretary, and any Assistant Vice President appointed for that purpose by the officer in charge of surely operations, shall each have authority to appoint individuals as attorneys -in -fact or under other appropriate titles with authority to execute on behalf of the company fidelity and surety bonds and other documents of similar character issued by the company in the course of its business... On any instrument making or evidencing such appointment, the signatures may be affixed by facsimile. On any instrument conferring such authority or on any bond or undertaking of the company, the seal, or a facsimile thereof, may be impressed or affixed or in any other manner reproduced; provided, however, that the seal shall not be necessary to the validity of any such instrument or undertaking." Extract from a Resolution of the Board of Directors of SAFECO INSURANCE COMPANY OF AMERICA and of GENERAL INSURANCE COMPANY OF AMERICA adopted July 28, 1970, "On any certificate executed by the Secretary or an assistant secretary of the Company setting out, (I) The provisions of Article V, Section 13 of the By -Laws, and (it) A copy of the power -of -attorney appointment, executed pursuant thereto, and (iii) Certifying that said power -of -attorney appointment is in full force and effect, the signature of the certifying officer may be by facsimile, and the seal of the Company may be a facsimile thereof." I, Stephanie Daley -Watson Secretary of SAFECO INSURANCE COMPANY OF AMERICA and of GENERAL INSURANCE COMPANY OF AMERICA, do hereby certify that the foregoing extracts of the By -Laws and of a Resolution of the Board of Directors of these corporations, and of a Power of Attorney issued pursuant thereto, are true and correct, and that both the By -Laws, the Resolution and the Power of Attorney are still in full force and effect. IN WITNESS WHEREOF, I have hereunto set my hand and affixed the facsimile seal of said corporation this I Z day of SFAL r Fof weSovo � �✓ �J92� \ aO STEtPAHvAlNIEDALEY-WATSO�N,SECRET ARY �tofwas�t� Safeco© and the Safeco logo are registered trademarks of Safeco Corporation. S-0974/DS 4/05 WEB PDF s, SECTION 00630 CERTIFICATE OF INSURANCE CONTRACTOR shall insert his own standard form for Certificate of Insurance. 7/96 Section 00630 Page I woo-';` C�ftTIFICATE OF INSUR ONCE PRODUCER - oATe OS/07/2008 - - THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS - - '.Marsh USA Inc. - - NO RIGHTS UPON THE CERTIFICATE HOLDER OTHER THAN THOSE PROVIDED IN THE POLICY. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE 411 East Wisconsin Avenue _ - AFFORDEDBY THE POLICIES DESCRIBED HEREIN. Suite 1600Milwaukee - Milwaukee, Wisconsin 53202w4479 COMPANIES AFFORDING COVERAGE Beatganp8 -See '*See Baba Attn: CPU, Phone (414) 2904912 Fax(414) 2904953 - Company' - ACE American Insurance Company Pan y CPU_Milmukee@mamh.com A P.O. Box 41484, Philadelphia, PA 19101 A+XV INSURED - _ Johnson Controls, Inc. Corp. Risk Mgmt.X-92 - Company Sentry Insurance ve Mutual A+ XV Johnson Controls Battery Group, Inc -. P.O.P.OBOX 591 it 5 - B 1800 North Point Drive, Stevens Pant, WI 4481 Johnson Controls Interiors, L.L.C. Milwaukee, WI 53201 " - Company Indemnity Insurance Company of North America Cal -Air, Inc. C and for CA, WI & EX WC: ACE American GES America, L.L.C. - - - Insurance Company A+XV Optima Batteries, Inc. US[ Companies - - P.O. Box41484, Philedel hie PA 19101 Company Lexington Insurance Company - A+XV "YorkInternationalCorporation - al D 10o Summer Street, Boston MA 02110 COVERAGESi: •,. '. This:Certificate'su"ersede$`and:re laces ari previous) Issued celYificate � �" ' THISIS TO ODIION OF THAT POLICIES OFINSURANCE DESCRIBED HEREIN HAVEBBEN ISSUED TO THE INSURED NAMED HEREIN FORTHE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REONPEMENT,TERM OR TON Of ANY CONTRACT OR OTHER DOCUMENT RESPECT TO WHICH THE CERTIFICATE MAY BE ISSUED OR SUBJECT MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL Tff TERNS, CONDITIONS AND EXCLUSIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. OF CO LTB TYPE OFINSURANCE POLICY NUMBER- POLICY EFFECTIVE POLICY EXPIRATION LIMITS DAM(MMIDDIYY) DATE(MWDDNY)- ATI GENERAL LIABILHY(1)(3)(4) - - GENERAL AGGREGATE $5.000.000 X COMMERCIAL GENERAL LIABIL-ITY- HDOG2373283A 10-1-2007 '. 10-1-2008 PRODUCTS-COMP/OPAGG $5,000,000 CLAIMS MADE aOCCUR" - - PERSONAL &ADV INJURY $5,000,000 EACH OCCURRENCE $5,000,000 OWNER'S& CONTRACTOR'S PROT )(- Contractual _ FIRE DAMAGE (Any one fire $ 5,000.000 X x.C.0 IExplosipn CPllapso, Undm ,nund) - - $ 50,000 X Addilmalbsurvc- . o Lomse>or s Cpmlodaw see Belpre MED EXP tAny one person) AUTOMOBILELIABILITY(2)(3)(4) - X ANY AUTO 90-04606-01 10-1-2007 10-1-2008 COMBINED SINGLE LIMIT $ 5,000,000 ALL OWNED AUTOS BODILY INJURY (Per person) SCHEDULED AUTOS X HIRED AUTOS NJURY BODILY eracci ent) X NON -OWNED AUTOS - PROPERTY DAMAGE GARAGE LIABILITY AUTO ONLY -EA ACCIDENT ANY AU70 - OTHER THAN AUTO ONLY: EACH ACCIDENT D EXCESS LIABILITY $ 5,000,000 X UMBRELIA FORM 5577735'- 10-1-2007 10-1-2008 EACH OCCURRENCE AGGREGATE $5,000,000 - - OTHER THAN UMBRELI-A FORM C WORKERS COMPENSATION AND WLRC444O94-ADS 1O-1-2007 10-1-2008 X WC STATU- OTH- 73 EMPLOYERS' LIABILITY (4) WLRC44473136- CA- Tonr LIMITS ER SCFC44473057-WI EL EACH ACCIDENT $1,000,000 THE PROPRIETOR/ X INCL WCUC44473OIA—EXWC - ELDISEASE-POLICY LIMIT $1,ODO,000 PARTNERS/EXECUTIVE EXCL OFFICERS ARE EL DISEASE -EACH EMPLOYEE $ 1,OD0,000 (1) ADDITIONAL INSURED: If required by contract, Includes coverage for Additional Insured's per attached Endorsement (2) ADDITIONAL INSURED: If raqutred by contract, Inchoate coverage!orAdditional Insured's and Loss Payee as required by contract. - S (3) PRIMARY COVERAGE: Where required by lease or contract this coverage is primary and not excess of orcontributing with other insurance or self -Insurance. 4 WAIVER OF SUBROGATION: Insureowivessubro atlon to the extent re uirMb contract DESCRIPTIONOFOPERATIONS/LOCATIONSNEHICLES/SPECIAL ITEMS JCI Contract No. Project Name: - Customer PO Number - - ;C,ERTIFICATEHOLDER., ,_- CANCELLATION-,-•, _;. SHOULD ANY OFTHE POLICIES DESCRIBED HEREIN BE CANCELLED BEFORE THE EX ORATION DATETHEREOF," THEISSUINGCOMPANY WILLENB6hYBR;QMAIL X DAYS WRITTEN NOTICE TO THE CERTIFICATE " HOLDERNAMEDHI2REN, MARSH USA INC BY �GS?f✓ems» ../�io-�-ri' pfl a p 0(tled /orinforma0 'P Rpae} NY ndamb 1I up�T1 rrmalip iM1 agagto}n c6 ralb8 p II bl f MwhUSAI on ih d}t 'ti Hth rq xnlh _sp [t J t tnpa M h USAI III oty tivAllh vqp 3pomlBlllryor oLapeb pl fpr nh : rtIX I b 1tl nYP IYn VP th) aHif h.l f �. h0.M a et n e Mn e $. `. :? h w i blhty vnlh p it LUApIv npY p6fpt RAbll Yp pp�plefnw I Yph a 0 s Td 1 M hUSA in 111 ty 0Y fit In N mP} kdwM1i4rYhev 9 tlth I Iv II be f m d h ml -h': "IaaMaY waa .Tha.ANOLiabl mebo'h q$plen neiRR c;a )nc.i@i:W WackorOtlVO:SJIle BiliCh(W o Ied0E0eManJ,UEAine Dada nihorol8 of avneulletA lotha inSumE VMM1 ma e3blHla�-n meM . POLICY NUMBER: HobG23719290:. COMMERICAL GENERAL LIABILITY THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART L Name of Additional Insured Persons Or Or anization s if required by contract, City of Fort Collins Purchasing 215 N. Mason 2nd Floor Fort Collins, CO 80524 Location(s) Of Covered Operations required by contract. 7 Information required to com lete this Schedule, if not shown above, will be shown in the Declarations. aecaon a —vvno is An msurea is amenaea to include as an additional insured the person(s) or organization(s) shown in the Schedule, but only with respect to liability for "bodily injury", "property damage" or "personal and advertising injury" caused solely by: 1. Your acts or omissions; or 2. The acts or omissions of those acting on your behalf; in the performance of your ongoing operations for the additional insured(s) at the localion(s) designated above. rul With respect to the Insurance afforded to these ad( insureds, the following additional. exclusions apply: This insurance does not apply to "bodily injury" or "property damage" occurring after: 1. All work, including materials, parts or equipment furnished in connection with such work, on the project (other than service, maintenance or repairs) to be performed by or on behalf of the additional insured(s) at the location of the covered operations has been completed; or 2. That portion of "your work" out of which the injury or damage arises has been put to its intended use by any person or organization other than another contractor or subcontractor engaged in performing operations for a principal as a part of the same #A2A section u — who Is An Insured is amended to include as an additional insured the person(s) or organization(s) shown in the Schedule, but only with respect to liability for "bodily injury" or "property damage" caused solely by "your work" at the location designated and described in the schedule of this endorsement performed for that additional insured and Included In the "products- SECTION 00635 CERTIFICATE OF SUBSTANTIAL COMPLETION TO: CITY OF FORT COLLINS (OWNER) DATE OF SUBSTANTIAL COMPLETION: PROJECT TITLE: City of Fort Collins Lighting and Retrofit Project PROJECT OR INCLUDE: OWNER: City of Fort Collins CONTRACT DATE: May 5, 2008 SPECIFIED PART SHALL LOCATION: Fort Collins, Colorado CONTRACTOR: Johnson Controls, Inc. The Work performed under this contract has been inspected by authorized representatives of the OWNER, CONTRACTOR, and the ENGINEER and the project (or specified part of the project, as indicated above) is hereby declared to be substantially completed on the above date. A tentative list of items to be completed or corrected is appended hereto. This list may not be exhaustive, and the failure to include an item on it does not alter the responsibility of the CONTRACTOR to complete all the Work in accordance with the Contract Documents. ENGINEER AUTHORIZED REPRESENTATIVE DATE The CONTRACTOR accepts the above Certificate of Substantial Completion and agrees to complete and correct the items on the tentative list within the time indicated. CONTRACTOR AUTHORIZED REPRESENTATIVE DATE The OWNER accepts the project or specified area of the project as substantially complete and will assume full possession of the project or specified area of the project at 12:01 a.m., on The responsibility for heat, utilities, security, and insurance under the Contract Documents shall be as set forth under "Remarks" below. CITY OF FORT COLLINS, COLORADO By: OWNER AUTHORIZED REPRESENTATIVE DATE 7/96 Section 00635 Page 1 SECTION 00640 CERTIFICATE OF FINAL ACCEPTANCE TO: Gentlemen: 20 You are hereby notified that on the day of , 20_ the City of Fort Collins, Colorado, has accepted the Work completed by for the City of Fort Collins project, City of Fort Collins Lighting and Retrofit Project. A check is attached hereto in the amount of $ as Final Payment for all Work done, subject to the terms of the Contract Documents which are dated In conformance with the obligations and guarantees the following date: Sincerely, Contract Documents for this project, your will continue for the specified time from OWNER: City of Fort Collins By: Title: ATTEST: Title: 7/96 Section 00640 Page 1 SECTION 00650 LIEN WAIVER RELEASE (CONTRACTOR) TO: City of Fort Collins, Colorado (OWNER) FROM: Johnson Controls, Inc. (CONTRACTOR) PROJECT: City of Fort Collins Lighting and Retrofit Project 1. The CONTRACTOR acknowledges having received payment, except retainage from the OWNER for all work, labor, skill and material furnished, delivered and performed by the CONTRACTOR for the OWNER or for anyone in the construction, design, improvement, alteration, addition or repair of the above described project. 2. In consideration of such payment and other good and valuable consideration, the receipt and adequacy of which are hereby acknowledged, the CONTRACTOR voluntarily waives all rights, claims and liens, including but not limited to, mechanic's liens, Miller Act claims (40 U.S.C.A. 270 a and b), stop notices, equitable liens and labor and material bond rights which the CONTRACTOR may now or may afterward have, claim or assert for all and any work, labor, skill or materials furnished, delivered or performed for the construction, design, improvement, alteration, addition or repair of the above described project, against the OWNER or its officers, agents, employees or assigns, against any fund of or in the possession or control of the OWNER, against the project or against all land and the buildings on and appurtenances to the land improved by the project. 3. The CONTRACTOR affirms that all work, labor and materials, furnished, delivered or performed to or for the construction, design, improvement, alteration, addition or repair of the project were furnished, delivered or performed by the CONTRACTOR or its agents, employees, and servants, or by and through the CONTRACTOR by various Subcontractors or materialmen or their agents, employees and servants and further affirms the same have been paid in full and have released in full any and all existing or possible future mechanic's liens or rights or claims against the project or any funds in the OWNER'S possession or control concerning the project or against the OWNER or its officers, agents, employees or assigns arising out of the project. 4. The CONTRACTOR agrees to defend and hold harmless the OWNER, the lender, if any, and the Surety on the project against and from 7/96 Section 00650 Page 1 any claim hereinafter made by the CONTRACTOR'S Subcontractors, materialmen, employees, servants, agents or assigns against the project or against the OWNER or its officers, employees, agents or assigns arising out of the project for all loss, damage and costs, including reasonable attorneys fees, incurred as a result of such claims. S. The parties acknowledge that the description of the project set forth above constitutes and adequate description of the property and improvements to which this Lien Waiver Release pertains. It is further acknowledged that this Lien Waiver Release is for the benefit of and may be relied upon by the OWNER, the lender, if any, and Surety on any labor and material bonds for the project. Signed this day of 20 CONTRACTOR M Title: ATTEST: Secretary STATE OF COLORADO ) )as. COUNTY OF LARIMER ) Subscribed and sworn to before me this 20_, by Witness my hand and official seal. My Commission Expires: Notary Public day of 7/96 Section 00650 Page 2 SECTION 00660 CONSENT OF SURETY TO: City of Fort Collins, Colorado (hereinafter referred to as the "OWNER") CONTRACTOR: Johnson Controls, Inc. PROJECT: City of Fort Collins Lighting and Retrofit Project CONTRACT DATE: May 5, 2008 In accordance with the provisions of the Contract between the OWNER and the CONTRACTOR as indicated above, for on bond of (Surety) hereby approves of the Final Payment to the CONTRACTOR, and agrees that Final Payment to the CONTRACTOR shall not relieve the Surety Company of any of its obligations to the OWNER, as set forth in the said Surety Company's Bond, IN WITNESS WHEREOF, the Surety Company has hereunto set its hand this day of , (Surety Company) ATTACH: Power of Attorney and Certificate of Authority of Attorney(s)-in-Fact. 7/96 Section 00670 Page 1 SECTION 00670 APPLICATION FOR EXEMPTION CERTIFICATE OR 0172 (12m) A COmORA6DO DEPART41ENT OF REVCNOE OENVERC000261 a2-2d16 CONTRACTOR APPLICATION OFNV FOR EXEMPTION CERTIFICATE Pursuantto Statute Section 39 26.114(1)(a)(XM The exemption certificate for which you are applying must be used only for the purpose of purchasing construct ion and building materials for the exempt project described below. This exemphandoes not include or apply to the purchase or rental of equipment, supplies, and matere is which are purchased, rented, or consumed by the contractor and which do not became part of the structure, highway, road, street, or other public works wind and used by the exempt organization. Any unauthorized use or the exemption certificate will result in revocation of your exemption certificate and other penalties provided by law. A separate certificate is required for each contract. Subcontractors will not be issued Certificates of Exemption by the Department of Revenue. It is the responsibility of the prim contractor to issue certificates to each of the subcontractors. (See reverse side). FAILURE TO ACCURATELY COMPLETE ALL BOXES WILL CAUSE THE APPLICATION TO BE DENIED. No. to be assigw.tlby OR drod 89rsuamNAcwwe 0170-750 (999)$0.00 CONTRACTOR INFORMATION rape amel A Jo�inson Controls, Inc. nep Pan r, e, caporsm name 'Olt 2d egi tatbentennial Rd. �a& °� A. Tocquigny --Malls dress: e rat e s d n ca'on Number: - "T9b �� tlamount oryour contract. $ 1,014,413.00 ( � ) 979-6846 B"73Y telephone rn 3b2' ( 303 )932-3754 .......wit ..... g--d.... nem er: EXEMPTION INFORMATION 'copies of contractor agreement pages (1) Identifying the contracting parties and (2) containing signatures of contracting parties must be attached. Name of exempt organrza ion (as shown on conlrect) - emplocanization s number. 98- Address of exempt organrzeUon (Q y, tale, ip). Principal contact at exempt organization'. rinctipal contact's telephone number: Physical location of projec site (give actual address when applicable and Ci ues antl/or County pes) where project Is located) sm,dWed y cetmcUon sars data, rmpad ."r, Day ear dare: I declare under penalty of perjury in the second degroc that the statements made in this application are true and complete to the best of my knowledge. Igna owner, partner er Orate o cer Time of coorrporateo wer. ate.. (/�' V/✓l Jai // Ji✓S 5 A/0 DO NOT WRITE BELOW THIS LINE Section 00670 Page 1 acceptable Schedule of Values established in paragraph 2.06 of the General Conditions (and in the case of Unit Price Work based on the number of units completed). 1. For Cost of Work: Progress payments on account of the Cost of the Work will be made as follows: a. Prior to Substantial Completion, in an amount equal to the percentage indicated below, but, in each case, less the aggregate of payments previously made and less such amounts as OWNER may withhold in accordance with paragraph 13.03.13 of the General Conditions. (1) 90 percent of Cost of the Work completed (with the balance being retainage). if the Work has been 50% completed as determined by OWNER, and if the character and progress of the Work have been satisfactory to OWNER, OWNER may determine that as long as the character and progress of the Work remain satisfactory, there will be no additional retainage on account of Work completed, in which case the remaining progress payments prior to Substantial Completion will be in an amount equal to 100% of the Work completed. (2) 90 percent of (with the balance being retainage) of the cost of materials and equipment not incorporated in the Work (but delivered, suitably stored and accompanied by documentation satisfactory to OWNER as provided in paragraph 13.02.A of the General Conditions). b. Upon Substantial Completion, in an amount sufficient to increase total payments to DESIGNBUILDER to 95 percent of the Contract Price (with the balance being retainage), less such amounts as OWNER shall determine that OWNER may withhold, in accordance with paragraph 13.03.13 of the General Conditions. 2. For DESIGN/BUILDER'S Fee: Progress payments on account of the DESIGN/BUILDER'S Fee will be made as follows: a. Payments prior to Substantial Completion will be in an amount equal to 90 percent of such Fee earned to the date of the approved Application for Payment (less in each case payments previously made on account of such fee) based on the progress of the Work measured by the Schedule of Values established as provided in paragraph 2.06.A of the General Conditions (and in the case of Unit Price Work on the number of units completed) and upon Substantial Completion in an amount sufficient to increase total payments to DESIGN/BUILDER on account of that fee to 95 percent of the DESIGN/BUILDER's Fee. c Special Notice Contractors who have completed this application in the past, please note the following changes in procedure The Department will no longer issue individual Certificates of exam ption to subcontractors. Only prime contrac- tors will receive a Contractor's Exemption Certificate on exempt projects. Upon receipt of the Certificate, the prime contractor should make a copy for each subcontractor involved in the project and complete it by filling in the subcontractor's name and address and signing it. The original Certificate should always be retained by the prime contractor. Copies of all Certificates that the prime contractor issued to subcontractors should be kept at the prime contractor's place of business for a minimum of three years and be available for inspection in the event of an audit. Once an 891t has been assigned to you, please use the next five numbers following it for any applications submitted for future projects. This should be your permanent number. For instance, if you were assigned 89- 12345-0001, every application submitted thereafter should contain 89-12345 on the application. The succeed- ing numbers will be issued by the Department of Revenue. DO NOT enter what you believe to be the next in sequence as this may delay processing of your application. Section 00670 Page 2 This document has important legal consequences; consultation with an attorney is encouraged with respect to its use or modification. This document should be adapted to the particular circumstances of the contemplated Project and the Controlling Law. City of Port Collins changes to this document are shown by underlining text that has been added and striking through text that has been deleted. STANDARD GENERAL CONDITIONS OF THE CONTRACT BETWEEN OWNER AND DESIGN/BUILDER Prepared by ENGINEERS JOINT CONTRACT DOCUMENTS COMMTr'ru and Issued and Published Jointly by A C National Society 1. C E Arofessional Enginn ASCE American Society eers of Civil Engineers a-+++rR+� t ���+��+���� ..„ •�+��>��� ProlessIona/Englnners In Private Practice PROFESSIONAL ENGINEERS IN PRIVATE PRACTICE a practice division of the NATIONAL SOCIETY OF PROFESSIONAL ENGINEERS AMERICAN COUNCIL OF ENGINEERING COMPANIES AMERICAN SOCIETY OF CIVIL ENGINEERS EICDC D-700 Standard General Conditions of the Contract Between Owner and Desip/Nnldor Copyright 02002 National Society of Professional Engineers for EICDC All �ghts tesetn�ed. EJCDC D-700 Standard ken ,.l Conditions ofthe Contmcl Between Owner and DesigtJUuilder Copyaight 02002 National Society ofllrofinsionnl Engineors for rJCDC. All tights reserved. These General Conditions have been prepared for use with either one of the two Agreements between Owner and Design/Builder (Nos. D-520 and D-525, 2002 Editions) of the Engineers Joint Contract Documents Committee. Their provisions are interrelated and a change in one may necessitate a change in the others. The suggested language and instructions contained in the Guide to Use of EJCDC Design/Build Documents (No. D-001, 2002 Edition) is also carefully interrelated with the language of these General Conditions. The Guide also contains comments concerning the use of the General Conditions. Copyright ©2002 National Society of Professional Engineers 1420 King Street, Alexandria, VA 22314-2794 American Council of Engineering Companies 1015 15th Street N.W., Washington, DC 20005 American Society of Civil Engineers 1801 Alexander Bell Drive, Reston, VA 20191-4400 EJCDC D-700 Standard Genoral Conditions of the Com.ot Betweon Ownor and DcsipBuildcr Copynght OQ2002 National Society of Professional Enginccm for EJCDC. All rights reserved. TABLE OF CONTENTS Page 3 ENVIRONMENTAL CONDITIONS...............................................................................7 .............................................................................................................................................. 7 4.uz ..:.tteFing o,te-' .d,to:S Subsurtace and PhysicalUonditions.............................................................................................7 4.03 Reference Points....................................................................................................................................................................9 4.04 44a ^A '^U ^ Asbestos PCBs Petroleum Hazardous Waste or Radioactive Material ....... 10 ARTICLE5 - BONDS AND INSURANCE.................................................................................................................................... 10 5.01 Performance. Payment and Other Bonds.............................................................................................................................11 5.02 Licensed Sureties and Insurers.............................................................................................................................................11 5.03 Certificates of Insurance...................................................................................................................................................... 11 5.04 Design/Builder's Liability Insurance. ................................................................................................................................... 11 5.05 Owner's Liability Insurance.................................................................................................................................................12 5.06 -P� Builders Risk Insurance.........................................................................................................................................12 5.07 Waiver of Rights..................................................................................................................................................................13 5.08 Receipt and Application of Insurance Proceeds...................................................................................................................14 5.09 Acceptance of Bonds and Insurance• Option to Replace.....................................................................................................14 5.10 Partial Utilization, Acknowledgment of Property Insurance...............................................................................................14 ARTICLE 6 - DESIGN/BUILDER'S RESPONSIBILITIES...........................................................................................................14 6.01 Design Professional Services...............................................................................................................................................14 6.02 Supervision and Superintendence of Construction..............................................................................................................15 6.03 Labor, Working Hours.........................................................................................................................................................15 6.04 Services. Materials, and Equipment.....................................................................................................................................15 6.05 Progress Schedule...............................................................................................................................................................A6 6.06 Concerning Subcontractors, Suppliers and Others..............................................................................................................A6 6.07 Patent Pees and Royalties....................................................................................................................................................16 6.08 Permits.................................................................................................................................................................................17 6.09 Laws or Regulations............................................................................................................................................................17 6.10 Taxes....................................................................................................................................................................................17 6.11 Use of Site and Other Areas.................................................................................................................................................17 6.12 Record Documents...............................................................................................................................................................18 6.13 Safety and Protection...........................................................................................................................................................18 6.14 Safety Representative...........................................................................................................................................................18 6.15 Hazard Communication Programs.......................................................................................................................................18 6.16 Emergencies.........................................................................................................................................................................18 6.17 Submittals............................................................................................................................................................................19 6.18 Continuing the Work............................................................................................................................................................19 6.19 Post -Construction Phase......................................................................................................................................................19 6.20 Design/Builders General Warranty and Guarantee.............................................................................................................19 6.21 Indemnification....................................................................................................................................................................19 6.22 Survival ofObligation s........................................................................................................................................................20 FJCDC D-700 Standard Gataral Conditions ofthe Contract Between Owner and Desipffleilder Copyright 02002 National Society of Professional Engineers for WCDC. All tights roscrved, Includes City of Fort Collins modi Boations dated 09/2004 ARTICLE7 - OTHER CONSTRUCTION......................................................................................................................................20 7.01 Related Work at Site............................................................................................................................................................20 7.02 Coordination........................................................................................................................................................................21 ARTICLE 8 - OWNER'S RESPONSIBILITIES.............................................................................................................................21 8.01 General.................................................................................................................................................................................21 8.02 Insurance .............................................................................................................................................................................. 21 8.03 Limitations on Owner's Responsibilities..............................................................................................................................21 8.04 Undisclosed Hazardous Environmental Condition..............................................................................................................22 8.05 Resident Project Representation ..........................................................................................................................................22 8.06 Owner's Consultant..............................................................................................................................................................22 ARTICLE 9 - CHANGES IN THE WORK CLAIMS....................................................................................................................22 9.01 Authorized Chanties in the Work.........................................................................................................................................22 9.02 Unauthorized Changes in the Work.....................................................................................................................................22 9.03 Claims..................................................................................................................................................................................22 9.04 Execution of Change Orders................................................................................................................................................22 9.05 Notice to Sureties.................................................................................................................................................................22 9.06 Effect of Change Orders......................................................................................................................................................23 ARTICLE10-COST OF THE WORK CASH ALLOWANCES UNIT PRICE WORK.............................................................23 10.01 Cost ofthe Work................................................................................................................................................................23 10.02 Cash Allowances................................................................................................................................................................25 10.03 Unit Prices..........................................................................................................................................................................25 ARTICLE 11 1-.CHANGE OF CONTRACT PRICE; CHANGE OF CONTRACT TIMES...........................................................25 11.01 Change of Contract Price ................... ..................................................... ..................... .................................... ................... 25 11.02 Change of Contract Times.................................................................................................................................................26 ARTICLE 12-TESTS AND INSPECTIONS; CORRECTION REMOVAL OR ACCEPTANCE OF DEFECTIVE CONSTRUCTIONOR WORK........................................................................................................................................................27 12.01 Notice of Defects...............................................................................................................................................................27 12.02 Access to Construction.......................................................................................................................................................27 12.03 Tests and Inspections........................................................ .................................... -.............................. .................... ........ 27 12.04 Uncovering Construction...................................................................................................................................................27 12.05 Owner May Stop Construction or Work... ................................... ............. ...................... .................................. ............. 28 12.06 Correction or Removal of Defective Construction or Work..............................................................................................28 12.07 Correction Period...............................................................................................................................................................28 12.08 Acceptance of Defective Construction...............................................................................................................................28 12.09 Owner May Correct Defective Construction or Work.... ................................... .................................. ............................ 28 12.10 No Limitation.....................................................................................................................................................................29 ARTICLE 13 - PAYMENTS TO DESIGN/BUILDER AND COMPLETION...............................................................................29 13.01 Schedule of Values............................................................................................................................................................29 13.02 Application for Pro ress Payment.....................................................................................................................................29 13.03 Review of Applications for Progress Payments.................................................................................................................29 13.04 Design/Builder'sWarranty of Title....................................................................................................................................30 13.05 Substantial Completion......................................................................................................................................................30 13.06 Partial Utilization...............................................................................................................................................................30 13.07 Final Inspection.. ............................... ...................................... ................. -- .......... ..................... ................................... 31 13.08 Final Payment....................................................................................................................................................................31 13.09 Final Completion Delayed.................................................................................................................................................31 13.10 Waiver of Claims...............................................................................................................................................................32 ARTICLE 14-SUSPENSION OF WORK AND TERMINATION...............................................................................................32 14.01 Owner May Suspend Work ............................ ................... ................................................... -........................................... 32 14.02 Owner May Terminate for Cause.......................................................................................................................................32 14.03 Owner May Terminate for Convenience, .................. ............................................................. ......................... . ............ -32 14.04 Design/Builder May Stop Work or Terminate...................................................................................................................33 ARTICLE15 -DISPUTE RESOLUTION......................................................................................................................................33 ARTICLE16 -MISCELLANEOUS...............................................................................................................................................33 16.01 Giving Notice................................................................................................................................................................I....33 16.02 Computation of Times.......................................................................................................................................................33 16.03 Cumulative Remedies........................................................................................................................................................33 16.04 Survival of Obligations......................................................................................................................................................34 16.05 Controlling Law.................................................................................................................................................................34 E7CUC D-700 Standard General Conditions ofthe Contract Behveen Omner and Design/Builder Copyright ©2002 National tiocicty of Professional Engineers for EfCDC. All rights reserved. hmledes City offort Collins modifications dated 09/2004 STANDARD GENERAL CONDITIONS OF THE CONTRACT BETWEEN OWNER AND DESIGN/BUILDER ARTICLE I —DEFINITIONS AND TERMINOLOGY 1.01 Defined Terms A. Wherever used in the Contract Documents and printed with initial or all capital letters, the following terms have the meanings indicated which are applicable to both the singular and plural thereof: 1. Addenda — Written or graphic instruments issued Prior to the opening of Proposals which clarifL correct or change the Request for Proposals or the Contract Documents 2. Agreement — The written instrument which is evidence of the agreement between Owner and Design/Builder covering the Work 3. Application for Payment — The form which is to be used by Design/Builder in requesting progress or final payments and which is to be accompanied by such supporting documentation as is required by the Contract Documents. 4. Asbestos — Any material that contains more than one percent asbestos and is friable or is releasing asbestos fibers into the air above current action levels established by the United States Occupational Safety and Health Administration. 5. Bonds — Performance and payment bonds and other instruments of security. 6. Change Order — A written order which is signed by Design/Builder and Owner which authorizes an addition, deletion or revision in the Work, or an adjustment in the Contract Price or the Contract Times, issued on or after the Effective Date of the Agreement. 7. Claim — A demand or assertion by Owner or Design/Builder seeking an adjustment of Contract Price or Contract Times, or both, or other relief with respect to the terms of the Contract. A demand for money or services by a third party is not a claim. 8. Conceptual Documents — The drawings and specifications and/or other graphic or written materials, criteria and information concerning Owner's requirements for the Project, such as design objectives and constraints, space, capacity and performance requirements, flexibility and expandability, including those items enumerated in the Request for Proposals which show or describe the character and scope of, or relate to, the Work to be performed or furnished and which have been prepared by or for Owner. 9. Construction — The result of performing or furnishing of labor, the furnishing and incorporating of materials and equipment into the Work and the furnishing of services (other than Design Professional Services) and documents, all as required by the Contract Documents. 10. Construction Subagreement — A written agreement between Design/Builder and a construction Subcontractor for provision of Construction. 11. Contract — The entire and integrated written agreement between Owner and Design/Builder concerning the Work. The Contract supersedes prior negotiations, representations, or agreements, whether written or oral. 12. Contract Documents — Those items so designated in the Agreement. Only printed or hard copies of the items listed in the Agreement are Contract Documents. 13. Contract Price — The moneys payable by Owner to Design/Builder for completion of the Work in accordance with the Contract Documents. 14. Contract Times — The numbers of days or the dates stated in the Agreement to (i) to achieve Substantial Completion and (ii) to complete the Work so that it is ready for final payment as evidenced by Owner's Representative's written recommendation for final payment, and in accordance with paragraph 13.08. 15. Design/Builder — The individual or entity with whom Owner has entered into the Agreement 15a. Design Materials — Any and all documents shop drawings, electronic information data plans drawings sketches illustrations specifications descriptions, models and other information developed prepared, furnished. delivered or required to be delivered by the Design/Builder (a) to the Owner under the Contract Documents or (b) developed or prepared by the Design/Builder specifically to discharge its duties under the Contract Documents PJCDC D-700 Standard General Conditions of the Contracl Between Owner and Design/Builder Copyright 02002 National Society of Professional Engineers for EJCDC. All rights reserved_ Includes City of Pon Collins modifications dated 09/2004 1 16. Design Subagreement - A written agreement between Design/Builder and a design professional for provision of Design Professional Services. 17. Design Professional Services - Services related to the preparation of Drawings, Specifications, and other design submittals specified by the Contract Documents and required to be performed by licensed design professionals, as well as other services provided by or for licensed design professionals during Bidding/Negotiating, Construction, or Operational phases. 18. Drmvings - Those portions of the Contract Documents prepared by or for Design/Builder and approved by Owner consisting of drawings, diagrams, illustrations, schedules and other data which show the scope, extent, and character of the Work. 19. Ffffeciive Date qj the Agreement - The date indicated in the Agreement on which it becomes effective, but if no such date is indicated it means the date on which the Agreement is signed and delivered by the last of the two parties to sign and deliver. 20. Field Order - A written order issued by Owner which orders minor changes in the Work in accordance with Article 9 - Changes in the Work: Claims but which does not involve a change in the Contract Price or the Contract Times. 21. Hazardous Environmental Condition - The presence at the Site of Asbestos, Hazardous Waste, PCBs, Petroleum Products or Radioactive Materials in such quantities or circumstances that may present a substantial danger to persons or property exposed thereto on connection with the Work. 22. Hazardous Waste -- The term Hazardous Waste shall have the meaning provided in Section 1004 of the Solid Waste Disposal Act (42 USC Section 6903) as amended from time to time. 23. Laws or Regulations - Any and all applicable laws, rules, regulations, ordinances, codes, and orders of any and all governmental bodies, agencies, authorities and courts having jurisdiction. 23a. Leval Holidays - Those holidays observed by the City of Port Collins. 24. Liens - Charges, security interests or encum- brances upon real property or personal property. 25. Milestone - A principal event specified in the Contract Documents relating to an intermediate completion date or time prior to Substantial Completion of all the Work. 26. Notice of Award - The written notice by Owner to the successful proposer stating that upon compliance by the successful proposer with the conditions precedent included therein, within the time specified, Owner will sign and deliver the Agreement. 27. Notice to Proceed - A written notice given by Owner to Design/Builder fixing the date on which the Contract Times will commence to run and on which Design/Builder shall start to perform the Work. 28. Owner - The individual or entity with whom Design/Builder has entered into the Agreement and for whom the Work is to be performed. 29. Owner's Consultant - An individual or entity with whom the Owner may contract to furnish services to Owner with respect to the Project and who is identified as such in the Supplementary Conditions. 30. Partial Utilization - Use by Owner of a substantially completed part of the Work for the purpose for which it is intended (or a related purpose) prior to Substantial Completion of all the Work. 31. PCBs-Polychlorinatedbiphenyls, 32. Petroleum - Petroleum, including crude oil or any fraction thereof which is liquid at standard conditions of temperature and pressure (60 degrees Fahrenheit and 14.7 pounds per square inch absolute), such as oil, petroleum, fuel oil, oil sludge, oil refuse, gasoline, kerosene, and oil mixed with other non -Hazardous Wastes and crude oils. 33. Project - The total construction of which the Work to be provided under the Contract Documents may be the whole, or a part as indicated elsewhere in the Contract Documents. 34. Proposal - The documents submitted by Design/Builder in response to the Request for Proposals setting forth the design concepts, proposed prices, and other conditions for the Work to be performed. 35. Radioactive Material - Source, special nuclear, or byproduct material as defined by the Atomic Energy Act of 1954 (42 USC Section 2011 et seq.) as amended from time to time. 35a. Regular Workint' Hours - 7.00 a.m. to 6700 n.m.. Monday through Friday, unless otherwise specified in the Contract Documents 36. Request.for Proposals -The document prepared by or for Owner specifying and describing Owners LJCDC D-700 Standard Ge.end Conditions of the Contract netween Ownor and DesigN[ittilder Copyright 02002 National Society of Professional Engineers for r'iCDC. All rights reserved. Includes City of Fort Collins modifications dated 09/2004 2 objectives and the procedure to be followed in preparing and submitting a Proposal and awarding a contract. 37. Resident Project Representative - The authorized representative of Owner who may be assigned to the Site or any part thereof. 37a. Samples - Physical examples of materials, equipment, or workmanship that are representative of some portion of the Work and which establish the standards by which such portion of the Work shall be judged. 38. Schedule of Values - A schedule prepared by Design/Builder and acceptable to Owner indicating that portion of the Contract Price to be paid for each major component of the Work. 38a. Shop Drawings - All drawings, diagrams, illustrations, schedules and other data or information which are specifically prepared or assembled by or for Design/Builder and submitted by Design/Builder to illustrate some portion of the Work. 39. Site - Lands or other areas designated in the Contract Documents as being furnished by Owner upon which Construction is to be performed, including rights -of - way and easements for access thereto, and such other lands furnished by Owner which are designated for use of Design/Builder. 40. Specifications - The part of the Contract Documents prepared by or for Design/Builder and approved by Owner consisting of written technical descriptions of materials, equipment, construction systems, standards and workmanship as applied to the Work and certain administrative details applicable thereto. 41. Subcontractor - An individual or entity other than a Supplier having a direct contract with Design/Builder or with any other Subcontractor for the performance of a part of the Work. 42. Submittal -- A written or graphic document prepared by or for Design/Builder which is required by the Contract Documents to be submitted to Owner by Design/Builder. Submittals may include Drawings, Specifications, progress schedules, shop drawings, samples, cash flow projections, and Schedules of Values. Submittals other than Drawings and Specifications are not Contract Documents. 43. Substantial Completion - The time at which the completed" as applied to all or part of the Work refer to Substantial Completion thereof. 44. Supplementary Conditions - The part of the Contract Documents which amends or supplements these General Conditions. 45. Supplier - A manufacturer, fabricator, supplier, distributor, materialman or vendor having a direct contract with Design/Builder or with any Subcontractor to furnish materials or equipment to be incorporated in the Work by Design/Builder or any Subcontractor. 45a, Underground Facilities - All pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels or other such facilities or attachments, and any encasement containing such facilities which have been installed underground to furnish any of the following services or materials: electricity, gases, steam, liquid petroleum products, telephone or other communications, cable television, sewage and drainage removal, traffic or other control systems or water. 46. Unit Price Work- Work to be paid for on the basis of unit prices. 47. Work - The entire construction or the various separately identifiable parts thereof required to be performed or furnished under the Contract Documents. Work includes and is the result of performing or furnishing Design Professional Services and Construction required by the Contract Documents. 48. Work Change Directive - A written directive to Design/Builder, issued on or after the Effective Date of the Agreement and signed by Owner ordering an addition, deletion or revision in the Work, or responding to differing site conditions under which the Work is to be performed or to emergencies. A Work Change Directive will not change the Contract Price or the Contract Times, but is evidence that the parties expect that the change directed or documented by a Work Change Directive will be incorporated in a subsequently issued Change Order following negotiations by the parties as to its effect, if any, on the Contract Price or Contract Times. 1.02 Terminology A. Intent of Certain Terms or Adjectives: 1. The word "day" shall constitute a calendar day of 24 hours measured. from midnight to the next midnight. Work (or a specified part) has progressed to the point where it is sufficiently complete, in accordance with the 2. The word "defective." when modifying the Contract Documents, so that the Work (or a specified part) words "Construction" or "Work" refers to Construction can be utilized for the purposes for which it is intended. or Work that is unsatisfactory, faulty, or deficient in that The terns "substantially complete" and "substantially ECDC D-700 Standard General Conditions ofthe Contras[ Botween Owner and Design/Builder Copyright 02002 Nmiovel Society of PmCessional Enginoers for GICDC. All rights reserved. Includes City of Pon Collins modifications dated 09/2004 3 it does not conform to the Contract Documents, or does not meet the requirements of any inspection, reference standard, test or approval referred to in the Contract Documents, or has been damaged prior to Owner's final payment (unless responsibility for the protection thereof has been assumed by Owner at Substantial Completion) provided that the defect was not caused by Owner. 3. The word "furnish." when used in connection with services materials or equipment, shall mean to supply and deliver said services, materials or equipment to the Site (or some other specified location) ready for use or installation and in usable or operable condition 4. The word "install." when used in connection with services, materials, or equipment, shall mean to put into use or place in final position said services, materials or equipment or equipment complete and ready for intended use. 5. The words "Perform" or `provide" when used in connection with services, materials, or equipment, shall mean to furnish and install said services materials or equipment complete and ready for intended use 6. When "furnish," "install;' "perform;' or "provide" is not used in connection with services, materials, or equipment in a context clearly requiring an obligation of Design/Builder, "provide" is implied 7. Unless stated otherwise in the Contract Documents, words or phrases which have a well-known technical or construction industry or trade meaning are used in the Contract Documents in accordance with that meaning. ARTICLE 2— PRELIMINARY MATTERS 2.01 Delivery of Bonds A. When Design/Builder delivers the executed Agreements to Owner, Design/Builder shall also deliver to Owner such Bonds as Design/Builder may be required to furnish in accordance with paragraph 5.0I.A. 2.02 Commencement of Contract Times; Notice to Proceed A. The Contract Times will commence to run on the thirtieth day after the Effective Date of the Agreement, or, if a Notice to Proceed is given, on the day indicated in the Notice to Proceed. A Notice to Proceed may be given at any time within thirty days after the Effective Date of the Agreement. Unless agFeea t—by�Owner --and 2.03 Starting the Work A. Design/Builder shall start to perform the Work on the date when the Contract Times commence to run. No Work shall be done at the Site prior to the date on which the Contract Times commence to run. 2.04 Before Starting the Work A. Design/Builder's Review of Contract Documents: Before undertaking each part of the Work, Design/Builder shall carefully study and compare those Contract Documents prepared by Owner and check and verify pertinent figures therein and all applicable field measurements. Design/Builder shall promptly report in writing to Owner any conflict, error, ambiguity, or discrepancy which Design/Builder may discover and shall obtain a written interpretation or clarification from Owner before proceeding with any Work affected thereby; however, Design/Builder shall not be liable to Owner for failure to report any conflict, error, ambiguity, or discrepancy in the Contract Documents unless Design/Builder knew or reasonably should have known thereof. B. Preliminary Schedules: Within 10 days after commencement of the Contract Times (unless otherwise specified in the Contract Documents), Design/Builder shall submit the following to Owner for its timely review: 1. A preliminary progress schedule indicating the times (numbers of days or dates) for starting and completing the various stapes of the Work, including any Milestones specified in the Contract Documents: 2. A preliminary schedule of Submittals which will list each required Submittal and the times for submitting, reviewing and processing each Submittal: in no case will a schedule be acceptable which allows less than seven (7) calendar days for each review by owner. 3. A preliminary Schedule of Values for all of the Work which will include quantities and prices of items which when added together equal the Contract Price and subdivides the Work into component parts in sufficient detail to serve as the basis for proress payments during performance of the Work Such prices will include an appropriate amount of overhead and profit applicable to each item of Work: and 4. A preliminary cash flow projection estimating that portion of the Contract Price to be due during each month of performance. r)CDC D-700 Standard General Conditions of tiro Contract Between Owner and Design/Builder Copyright 02002 National Society of Professicarn Engineers for P.7CDC. All rights reserved. Ineledes City ofPorl Collins modifications dated 0912004 4 B. Final Payment. Upon final completion and acceptance of the Work in accordance with paragraph 13.08 of the General Conditions and statutorily required procedures as set forth in Section 16.05.A of the General Conditions, OWNER shall pay remainder of the Contract Price. Article 10. DESIGN/BUILDER'S REPRESENTATIONS 10.01. DESIGN/BUILDER makes the following representations: A. DESIGN/BUILDER has examined and carefully studied the Contract Documents (including the Addenda) listed in paragraphs 12.0l.A. B. DESIGN/BUILDER has visited the Site and become familiar with and is satisfied as to the general, local and Site conditions that may affect cost, progress, performance or furnishing of the Work. C. DESIGN/BUILDER is familiar with and is satisfied as to all federal, state and local Laws and Regulations that may affect cost, progress, performance or furnishing of the Work. D. DESIGN/BUILDER has carefully studied all reports of explorations and tests of subsurface conditions at or contiguous to the Site and all drawings of physical conditions in or relating to existing surface or subsurface structures at or contiguous to the Site which have been made available by OWNER. E. DESIGN/BUILDER is aware of the general nature of work to be performed by OWNER and others at the Site that relates to the Work as indicated in the Contract Documents. F. DESIGN/BUILDER has correlated the information known to DESIGN/BUILDER, information and observations obtained from visits to the Site, reports and drawings identified in the Contract Documents and all additional examinations, investigations, explorations, tests, studies and data with the Contract Documents. G. DESIGN/BUILDER has given OWNER written notice of all known conflicts, errors, ambiguities or discrepancies that DESIGN/BUILDER has discovered in the Contract Documents and the written resolution thereof by OWNER is acceptable to DESIGN/BUILDER, and the Contract Documents and the written resolution thereof by OWNER is acceptable to DESIGN/BUILDER, and the Contract Documents are generally sufficient to indicate and convey understanding of all terms and conditions for performance and furnishing of the Work. Article 11. ACCOUNTING RECORDS C. Evidence of Insurance: Before any Work at the Site is started, Design/Builder and O -^- Shall ^^_w deliver to the other, Fti ficate of instiFaHee as Fequired b paFagFaph ."��^d d —shall deliver to Owner certificates of insurance (and other evidence of insurance requested by Owner) which Design/Builder is required to purchase and maintain in accordance with Article 5 - Bonds and Insurance. 2.05 Initial Conference A. Within twenty days after the Contract Times start to run, Design/Builder will arrange a conference attended by Owner and Design/Builder and others as appropriate to establish a working understanding among the parties as to the Work and to discuss the design concepts, schedules referred to in paragraph 2.04.13, procedures for handling Submittals, processing Applications for Payment, maintaining required records, items required pursuant to paragraph 8.01.A.6 and other matters. 2.06 Initial Acceptance of Schedules A. At least ten days before submission of the first Application for Payment (unless otherwise provided in the Contract Documents), Design/Builder will arrange a conference attended by Design/Builder, Owner and others as appropriate to review for acceptability the schedules submitted in accordance with paragraph 2.04.B. Unless otherwise provided in the Contract Documents, before any work at the site begins, a conference attended by Design/Builder, Owner's Representative and others as designated by Owner will be held to review for acceptability to Owner as provided herein the schedules submitted in accordance with paragraph 2.04.13, Design/Builder shall have an additional ten days to make corrections and adjustments and to complete and resubmit the schedules. No progress payment shall be made to Design/Builder until the acceptable schedules are submitted to Owner. 1. The Progress schedule will be acceptable to Owner if it provides an orderly progression of the Work to completion within any specified Milestones and the Contract Times. Such acceptance will not impose on Owner responsibility for the progress schedule, for sequencing, scheduling or progress of the Work nor interfere with nor relieve Design/Builder from Design/Buildees full responsibility therefore 2. Design/Builder's schedule of Submittals will be acceptable to Owner if it provides a workable arrangement for reviewing and processing the required Submittals. 3. Design/Builder's Schedule of Values will be acceptable to Owner as to form and substance if it provides a reasonable allocation of the Contract Price to component parts of the work. ARTICLE 3 - CONTRACT DOCUMENTS: INTENT, AMENDING, REUSE 3.01 Intent A. The Contract Documents are complementary; what is called for by one is as binding as if called for by all. B. It is the intent of the Contract Documents to describe a functionally complete Project (or part thereof) to be designed and constructed in accordance with the Contract Documents. Any labor, documentation, services, materials, or equipment that may reasonably be inferred from the Contract Documents or from prevailing custom or trade usage as being required to produce the intended result will be furnished and performed whether or not specifically called for at no additional cost to Owner. C. Whenever in the Contract Documents the terns "as ordered", "as directed", "as required", "as approved" or terms of like effect or import are used, or the adjectives "reasonable", "suitable", "acceptable", "proper" or "satisfactory" or adjectives of like effect or import are used to describe a requirement, direction, review or judgment of Owner as to the Work, it is intended that such requirement, direction, review or judgment will be solely to evaluate, in general, the completed Work for compliance with the requirements of and information in the Contract Documents and conformance with the design concept of the completed Project as a functioning whole as shown or indicated in the Contract Documents (unless there is a specific statement indicating otherwise). The use of any such term or adjective shall not be effective to assign to Owner any duty or authority to supervise or direct the furnishing or performance of the Work or any duty or authority to undertake responsibility contrary to any provision of the Contract Documents. 3.02 Reference Standards A. Standards, Specifications, Codes, Laws or Regulations. I. Reference to standards_ specifications, manuals or codes of any technical society, organization or association, or to Laws or Regulations, whether such reference be specific or by implication, shall mean the latest standard, specification, manual, code, or Laws or Regulations in effect on the last day for receipt of Proposals except as may be otherwise specifically stated in the Contract Documents. E1CDC D-700 Standard General Conditions cfthe Conooet nclwecn Owner and Design/nnilder Copydght©2002 National Society of Professional Engineers fen LJCDC_ All nghlsreservcd. Includes City of Pon Coll ins modifications dated 09/2004 5 2. No provision of any such standard, specification manual code or instruction of a Supplier shall be effective to chance the duties and responsibilities of Owner, Design/Builder, or any of their subcontractors, consultants, agents, or employees from those set forth in the Contract Documents, nor shall it be effective to assign to Owner any duty or authority to supervise or direct the furnishing or performance of the Work or any duty or authority to undertake responsibility inconsistent with the provisions of the Contract Documents. 3.03 Resolving Discrepancies A. In the event of a discrepancy between the Conceptual Documents on the one hand and the Proposal or Drawings or Specifications on the other hand, the Conceptual Documents will control except when Owner has approved a Submittal pursuant to paragraph 6.17.B. B. Except as otherwise specifically stated in the Contract Documents, the provisions of the Contract Documents shall take precedence in resolving any conflict, error, ambiguity, or discrepancy between the provisions of the Contract Documents and: 1. The provisions of any such standard, specification, manual, code, or instruction (whether or not specifically incorporated by reference in the Contract Documents); or 2. The provisions of any such Laws or Regulations applicable to the performance of the Work (unless such an interpretation of the provisions of the Contract Documents would result in violation of such Law or Regulation). 3. In the event of conflicting or ambiguous provisions within the Contract Documents, specifications will take precedence over the drawings and addenda will take precedence over both. Notwithstanding the foregoing, the more specific provision will take precedence over the less specific: the more stringent will take precedence over the less stringent; the more expensive item will take precedence over the less expensive. On all drawings, figures take precedence over scaled dimensions. Scaling of dimensions if done is done at the Design/Builder's own risk. C. If, during the performance of the Work, Design/Builder discovers any conflict, error, ambiguity or discrepancy within the Contract Documents or between the Contract Documents and any provision of any such Law or Regulation applicable to the performance of the Work or of any such standard, specification, manual or code or of any instruction of any Supplier referred to in paragraph 3.03.11, Desien/Builder shall report it to Owner in writing at once, and Design/Builder shall not proceed with the Work affected thereby (except in an emergency as authorized by paragraph 6.16) until an amendment or supplement to the Contract Documents has been issued by one of the methods indicated in paragraph 3.04.A: provided, however, that Design/Builder shall not be liable to Owner for failure to report any such conflict error, ambipuity, or discrepancy unless Design/Builder knew or reasonably should have known thereof 3.04 Amending and Supplementing Contract Documents A. The Contract Documents may be amended to provide for additions, deletions, and revisions in the Work or to modify the terms and conditions thereof in one or more of the following ways: 1. Owner's approval of required Submittals (pursuant to paragraph 6.17.B); 2. A Work Change Directive: 3. A Change Order: 4. A Field Order; 5. A formal Written Amendment. 3.05 Reuse of Doeuments Use of Design Materials A. All documents including Drawings and Specifications prepared or furnished by Design/Builder pursuant to this Agreement are for Design/Builder's own use, and Design/Builder shall retain an ownership and property interest therein whether or not the Project is completed. Owner may make and retain copies for information and reference in connection with the use and occupancy of the Project by Owner and others. However, such documents are not intended or represented to be suitable for reuse by Owner or others on extensions of the Project or on any other project. Any reuse or any continued use after any termination without written verification or adaptation by Design/Builder for the specific purpose intended will be at Owner's sole risk and without liability or legal exposure to Design/Builder and Owner shall indemnify and hold harmless Design/Builder and Subcontractors from all claims, damages, losses and expenses including attorneys' fees arising out of or resulting therefrom. Any such verification or adaptation will entitle Design/Builder to further compensation at rates to be agreed upon by Owner and Design/Builder. The Owner shall have unlimited rights to copy and use in connection with the Project all Desien Materials, including the right to use same on the Project at no additional cost to the Owner, regardless of de ree of completion, provided that said services performed have been fully paid for as required by the terms of this Agreement The Design/Builder agrees to and does hereby grant to the Owner and any assignee or successor of the Owner as owner of the EJCDC D-700 Standard General Conditions orthe Contraot Eetwcen Owner and Ne gnifnnildor Copy6ght O2002 National Society of Professional Engineers for EJCDC. All rights resmve& Inoludes City of Fon Collins nWifieations dated 09/2004 6 Project a royalty -free license to any such Design Materials as to which the Design/Builder may assert any rights under the patent or copyright laws. The Design/Builder hereby assigns outright and exclusively to the Owner all copyrights in the design appearance of the Project The Design/Builder, as part of its agreements with any Subcontractor or consultant, will secure such license and use rights from each such entity, and shall defend, indemnify and hold the Owner and any successors or assigns harmless from any claims by such entities for copyright or patent infringement. B. The Drawings, Specifications and other documents prepared for this Project are for use solely with respect to this Project and the author of these documents, consistent with Owner's ownership of the design, shall retain all common law, statutory and other reserved rights, including the copyright. The Owner shall be permitted to retain copies, including reproducible copies, of the Drawings, Specifications and other documents for information and reference in connection with the Owner's use and occupancy of the Project. The Drawings, Specifications or other documents shall not be used by the Owner or others on other projects. Submission or distribution of documents to meet official regulatory requirements or for other similar purposes in connection with the Project is not to be construed as publication in derogation of the rights reserved herein. C. Subject to Owner's remedies for a default, the Owner shall release the Design/Builder, its Subcontractors, consultants, and their respective agents and employees from all Owner's claims, liabilities, demands, actions, costs and expenses (including reasonable attorney's and expert's fees and costs) (a) arising from any use by the Owner, its successors or assigns of such Design Materials if the Design/Build Agreement is terminated by the Owner prior to Substantial Completion of the Work, or (b) arising as a result of amendments or modifications of any such Design Materials made without the prior consent of Design/Builder, and which do not result from errors, omissions or negligence in the Design Materials supplied hereunder. D. Upon conclusion of the Project and before final payment, Design/Builder shall provide Owner with reproducible drawings and electronic computer files of the Project containing accurate information on the Project as constructed. Drawings shall be of archival quality, prepared on stable mylar base material using a non -fading process proven suitable for long-term storage and high -quality reproduction. Electronic computer files shall be in AutoCAD Version 1.3 format. 3.06 Electronic Data A. Copies of data furnished by Owner to obtained or derived from such electronic files will be at the user's sole risk. If there is a discrepancy between the electronic files and the hard copies, the hard copies govern. B. Because data stored in electronic media format can deteriorate or be modified inadvertently or otherwise without authorization of the data's creator, the party receiving electronic files agrees that it will perform acceptance tests or procedures within 60 days, after which the receiving party shall be deemed to have accepted the data thus transferred. Any errors detected within the 60-day acceptance period will be corrected by the transferring party. C. When transferring documents in electronic media format, the transferring party makes no representations as to long term compatibility, usability, or readability of documents resulting from the use of software application packages, operating systems, or computer hardware differing from those used by the data's creator. ARTICLE 4 — AVAILABILITY OF LANDS; DIFFERING SITE SUBSURFACE AND PHYSICAL CONDITIONS; REFERENCE POINTS; HAZARDOUS ENVIRONMENTAL CONDITIONS 4.01 Availability of Lands A. Owner shall furnish the Site. Owner shall notify Design/Builder of any encumbrances or restrictions not of general application but specifically related to use of the Site which Design/Builder will have to comply in performing the Work. Unless otherwise provided in the Contract Documents, Owner will obtain in a timely manner and pay for easements for permanent structures or permanent changes in existing facilities. If Design/Builder and Owner are unable to agree on entitlement to or the amount or extent of any adjustments in the Contract Price or the Contract Times as a result of any delay in Owner's furnishing the Site, Design/Builder may make a Claim therefor as provided in Article 9. B. Upon reasonable written request, Owner shall furnish Design/Builder with a current statement of record legal title and legal description of the lands upon which the Construction is to be performed and Owner's interest therein as necessary for giving notice of or filing a mechanic's lien against such lands in accordance with applicable Laws or Regulations. C. Design/Builder shall provide for all additional lands and access thereto that may be required for temporary construction facilities or storage of materials and equipment. Design/Builder or Design/Builder to Owner that may be relied upon are limited to the printed copies (also known as hard 4.02 Differing Site r_nditio •ts Subsurface and Physical copies). Piles in electronic media format of text, data, Conditions graphics, or other types are furnished only for the convenience of the receiving party. Any conclusion or information EICDC D-000 Standard General Conditions ofthe Contrao BemcGt owner aad DesigNBaildcr Copyright©2002 National Society of Professional Eogineors for EJCDC. All rights reserved. ruclodes City of Fort Collins modifications dated 09/2004 7 A. Design/Builder shall promptly, and before the conditions are disturbed, give a written notice to Owner of (i) subsurface or latent physical conditions at the Site which differ materially fiom those indicated in the Contract Documents, or (ii) unknown physical conditions at the Site, of an unusual nature, which differ materially from those ordinarily encountered and generally recognized as inhering in work of the character called for by the Contract Documents, B. Owner will investigate the Site conditions promptly after receiving the notice. If the conditions do materially so differ and cause an increase or decrease in the Design/Builder's cost of, or the time required for, performing any part of the Work, whether or not changed as a result of the conditions, an equitable adjustment shall be made under this clause and the Contract Price or Times modified in writing by Change Order in accordance with Article 9. C. No request by Design/Builder for an equitable adjustment under paragraph 4.02 shall be allowed unless Design/Builder has given the written notice required; provided that the time prescribed in 9.03.A for giving written notice may be extended by Owner. D. The provisions of this paragraph 4.02 are not intended to apply to a Hazardous Environmental Condition uncovered or revealed at the Site. A. Reports and Drawings: Refer to these Supplementary Conditions for identification of: I. Subsurface Conditions: Those reports of explorations and tests of subsurface conditions at or contiguous to the site that have been utilized by Owner in preparing the Contract Documents, including the following: See Section 00800 Supplementary Conditions Design/Builder may rely upon the accuracy of the technical data contained in the geoteehnical documents, but not upon nontechnical data, interpretation or opinions contained therein or upon the completeness of any information in the report. 2. Physical Conditions: Those drawings of physical conditions in or relating to existing surface or subsurface structures at or contiguous to the site (except Underground Facilities) that have been utilized by OWNER in preparing the Contract Documents. a. No drawings of physical conditions in or relating to existing surface or subsurface structures (except Underground Facilities referred to in Paragraph 4.02.G) which are at or contiguous to the site have been utilized in preparation of the Contract Documents, except the following: See Section 00800 Supplementary Conditions B. Limited Reliance by Design/Builder Authorized, Technical Data: Design/Builder may rely upon the general accuracy of the "technical data" contained in such reports and drawings, but such reports and drawings are not Contract Documents. Such "technical data" is identified in the Request for Proposals or in these Supplementary Conditions. Except for such reliance on such "technical data", Design/Builder may not rely upon or make any claim against Owner, with respect to: (i) the completeness of such reports and drawings for Design/Builder's purposes, including, but not limited to, any aspects of the means, methods, techniques, sequences and procedures of construction to be employed by Design/Builder and safety precautions and programs incident thereto, or (ii) other data, interpretations, opinions and information contained in such repots or shown or indicated in such drawings, or (iii) any Design/Builder interpretation of or conclusion drawn from any "technical data" or any such data, interpretations, opinions or information. C. Notice of Differing Subsurface or Physical Conditions: If Design/Builder believes that any subsurface or physical condition at or contiguous to the site that is uncovered or revealed either: 1. is of such a nature as to establish that any "technical data" on which Design/Builder is entitled to rely as provided in paragraphs 4.02.A and 4.02.13 is materially inaccurate, or 2. is of such a nature as to require a change in the Contract Documents, or 3. differs materially from that shown or indicated in the Contract Documents, or 4. is of an unusual nature, and differs materially from conditions ordinarily encountered and generally recognized as inherent in work of the character provided for in the Contract Documents; or 5. is of such a nature as to reasonably be suspected of containing or constituting Asbestos, PCBs, Petroleum, Hazardous Waste, or Radioactive Material, or such other substances or materials that may result in significant damage or injury or require compliance with specifically applicable regulatory requirements, unless confirmation of the absence of such condition has previously been provided; then Design/Builder shall, immediately after becoming aware thereof and before further disturbing conditions affected thereby or performing any Work in connection therewith (except in an emergency as permitted by paragraph 6.16), notify Owner in writing about such condition. Design/Builder shall not further disturb such conditions or perform any Work in connection therewith (except as aforesaid) until receipt of written order to do so. D. Owner's Review: Owner will promptly review the pertinent conditions and determine the necessity of obtaining additional exploration or tests with respect thereto. EJCDC D-000 Standard General Conditions ofthe Contraq Between Owner and Design/nnilder Copyright ©2002 National Society of Professional Bnginecrs for EJCDC. All rights reserved. Includes City of FortCollins ntodifteatlo s dated 09/2004 8 E. Possible Contract Documents Change: If Owner concludes that a change in the Contract Documents is required as a result of a condition that meets one or more of the categories in paragraph 4.02.C, a Work Change Directive or a Change Order will be issued as provided in Article 9 to reflect and document the consequences of such change. F. Possible Price and Times Adjustments: An equitable adjustment in the Contract Price or in the Contract Times, or both, will be allowed to the extent that the existence of such uncovered or revealed condition causes an increase or decrease in Design/Builders cost of, or time required for performance of, the Work; subject, however, to the following: 1. such condition must meet any one of more of the categories described in paragraph 4.02.C; 2. a change in the Contract Documents pursuant to paragraph 4.02.E will not be an automatise authorization of nor a condition precedent to entitlement to any such adjustment; 3. with respect to Work that is paid for on a Unit Price Basis, any adjustment in Contract Price will be subject to the provisions of paragraph 10.03; and 4. Design/Builder shall not be entitled to any adjustment in the Contract Price or Times if: a. Design/Builder knew of the existence of such conditions at the time Design/Builder made a final commitment to Owner in respect of Contract Price and Contract Times by the submission of a bid or becoming bound under a negotiated contract; or b. the existence of such condition could reasonably have been discovered or revealed as a result of any examination, investigation, exploration, test or study of the site and contiguous areas required by the Request for Proposals or Contract Documents to be conducted by or for Design/Builder prior to Design/Builder's making such final commitment; or c. Design/Builder failed to give the written notice within the time and as required by Paragraph 4.02.0 above. 5. If Owner and Design/Builder are unable to agree on entitlement to or as to the amount or length of any such equitable adjustment in the Contract Price or Contract Times, a claim may be made therefor as provided in Articles 10 and 11. However, Owner shall not be liable to Design/Builder for any claims, costs, losses or damages sustained by Design/Builder on or in connection with any other project or anticipated project. G. Physical Conditions— Underground Facilities: 1. Shown or Indicated: The information and data shown or indicated in the Contract Documents with respect to existing Underground Facilities at or contiguous to the site is based on information and data furnished to Owner by the owners of such Underground Facilities or by others. Unless it is otherwise expressly provided in the Supplementary Conditions, Owner shall not be responsible for the accuracy or completeness of any such information or data, and the cost of all of the following will be included in the Contract Price and Design/Builder shall have full responsibility for: reviewing and checking all such information and data, b. locating all Underground Facilities shown or indicated in the Contract Documents, c. coordination of the Work with the owners of such Underground Facilities during construction, and d. the safety and protection of all Underground Facilities as provided in paragraph 6.13 and repairing any damage thereto resulting from the Work. 2. Not Shown or Indicated: If an Underground Facility is uncovered or revealed at or contiguous to the site which was not shown or indicated in the Contract Documents, Design/Builder shall, immediately after becoming aware thereof and before further disturbing conditions affected thereby or performing any Work in connection therewith (except in an emergency as required by paragraph 6.16), identify the owner of such Underground Facility and give written notice to that owner and to Owner. Owner will promptly review the Underground Facility and determine the extent, if any, to which a change is required in the Contract Documents to reflect and document the consequences of the existence of the Underground Facility. If Owner concludes that a change in the Contract Documents is required, a Work Change Directive or a Change Order will be issued as provided in Article 9 to reflect and document such consequences. During such time, Design/Builder shall be responsible for the safety and protection of such Underground Facility as provided in paragraph 6.12. Design/Builder may be allowed an increase in the Contract Price or an extension of the Contract Times, or both, to the extent that they are attributable to the existence of any Underground Facility that was not shown or indicated in the Contract Documents and that Design/Builder did not know of and could not reasonably have been expected to be aware of or to have anticipated. If Owner and Design/Builder are unable to agree on entitlement to or the amount or length of any such adjustment in Contract Price or Contract Times, Design/Builder may make a claim therefor as provided in Articles 10 and 11. However, Owner shall not be liable to Design/Builder for any claims, costs, losses or damages incurred or sustained by Design/Builder on or in connection with any other project or anticipated project. EICDC D-000 Standard Geocral Conditions of the Conh'act netween Owner and DesignBailder Copyright 02002 National Society of Professional Engineers for FJCDC. All nghts reserved. Includes City of Fort Collins modi 6cations dated 092004 9 4.03 Reference Points A. Design/Builder shall be responsible for laying out the Work and shall protect and preserve the reference points and property monuments established by Owner pursuant to paragraph 8.01.A.6.e, and shall make no changes or relocations without the prior written approval of Owner. Design/Builder shall report to Owner whenever any reference point or property monument is lost or destroyed or requires relocation because of necessary changes in grades or locations, and shall be responsible for the accurate replacement or relocation of such reference points or property monuments by professionally qualified personnel. Asbestos, PCBs, Petroleum, Hazardous Waste or Radioactive Material A. Design/Builder will not be responsible for any Hazardous Environmental Condition encountered at the Site which was not identified in the Contract Documents to be within the scope of the Work. Design/Builder shall be responsible for materials creating a Hazardous Environmental Condition created by any materials brought to the Site by Design/Builder, Subcontractors, Suppliers or anyone else for whom Design/Builder is responsible Owner shall be responsible for any Asbestos, PCBs, Petroleum, Hazardous Waste or Radioactive Material uncovered or revealed at the site which was not shown or indicated in Drawings or Specifications or identified in the Contract Documents to be within the scope of the Work and which may present a substantial danger to persons or property exposed thereto in connection with the Work at the site unless such substance or material should have been ascertained by Design/Builder in accordance with paragraph 4.02.C.5. OWNER shall not be responsible for any such materials brought to the site, managed stored or disposed of by Design/Builder Subcontractors. Suppliers, or anyone else for whom Design/Builder is responsible.. B. If Design/Builder encounters a Hazardous Environmental Condition, Design/Builder shall immediately: (i) secure or otherwise isolate such condition; (ii) stop all Construction in connection with such condition and in any area affected thereby (except in an emergency as required by paragraph 6.16); and (iii) notify Owner (and thereafter confirm such notice in writing). Owner shall promptly determine the necessity of retaining a qualified expert to evaluate such condition or take corrective action, if any. C. Design/Builder shall not be required to resume Construction in connection with such Hazardous Environmental Condition or in any such affected area until after Owner has obtained any required permits related thereto and delivered to Design/Builder written notice (i) specifying that such condition and any affected area is or has been rendered safe for the resumption of Construction, or (ii) specifying any special conditions under which such Construction may be resumed safely. If Owner and Design/Builder cannot agree as to entitlement to or the amount or extent of an adjustment, if any, in Contract Price or Contract Times as a result of such Construction stoppage or such special conditions under which Construction is agreed to be resumed by Design/Builder, either party may make a Claim therefor as provided in Article 9. D. If after receipt of such special written notice Design/Builder does not agree to resume Construction based on a reasonable belief it is unsafe, or does not agree to resume such Construction under such special conditions, then Owner may order such portion of the Work that is related to such Hazardous Environmental Condition to be deleted from the Work. If Owner and Design/Builder cannot agree as to entitlement to or the amount or extent of an adjustment, if any, in Contract Price or Contract Times as a result of deleting such portion of the Work, then either party may make a Claim therefor as provided in Article 9. Owner may have such deleted portion of the Work performed by Owner's own forces or others in accordance with Article 7. E. To the fullest extent permitted by Laws or Regulations, Owner shall indemnify and hold harmless Design/Builder, Subcontractors, Suppliers and the officers, directors, partners, employees, agents, other consultants and subcontractors of each and any of them from and against all claims, costs, losses and damages (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals and all court or arbitration or other dispute resolution costs) arising out of or resulting from such Hazardous Environmental Condition, provided that such Hazardous Environmental Condition: (i) was not shown or indicated in the Contract Documents to be included in the scope of the Work, and (iii) was not created by Design/Builder or by anyone for whom Design/Builder is responsible. Nothing in this paragraph 4.04.E shall obligate Owner to indemnify any individual or entity from and against the consequences of that individual's or entity's own negligence. F. To the fullest extent permitted by Laws or Regulations, Design/Builder shall indemnify and hold harmless Owner, Owner's Consultant and the officers, directors, partners, employees, agents, other consultants and subcontractors of each and any of them from and against all claims, costs, losses and damages (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals and all court or arbitration or other dispute resolution costs) arising out of or resulting from such Hazardous Environmental Condition created by Design/Builder or anyone for whom Design/Builder is responsible. Nothing in this paragraph 4.04.17 shall obligate Design/Builder to indemnify any individual or entity from and against the consequences of that individual's or entity's own negligence. ARTICLE 5 — BONDS AND INSURANCE C]CDC D-700 Standard General Condition, of the Contract Between Owner and Dcsign/auilder Copyright CG2002 National Society of Professional Engineers for MCDC. All tights reserved Includes City of Pon Conies modifications dated 09/2004 10 5.01 Performance, Payment and Other Bonds A. Design/Builder shall furnish performance and payment Bonds, each in an amount at least equal to the Contract Price as security for the faithful performance and payment of all Design/Builder's obligations to furnish, provide and pay for Work and related materials under the Contract Documents. These Bonds shall remain in effect at least until one year after the date when final payment becomes due, except as provided otherwise by Laws or Regulations or by the Contract Documents. Design/Builder shall also furnish such other Bonds as are required by the Contract Documents. B. All Bonds shall be in the form prescribed by the Contract Documents except as provided otherwise by Laws or Regulations, and shall be executed by such sureties as are named in the current list of "Companies Holding Certificates of Authority as Acceptable Sureties on Federal Bonds and as Acceptable Reinsuring Companies" as published in Circular 570 by the Audit Staff, Bureau of Government Financial Operations, U.S. Department of the Treasury. All Bonds signed by an agent must be accompanied by a certified copy of such agent's authority to act. C. If the surety on any Bond furnished by Design/Builder is declared a bankrupt or becomes insolvent or its right to do business is terminated in any state where any part of the Project is located or it ceases to meet the requirements of paragraph 5.01.13 and 5.02, Design/Builder shall within twenty ten 10 days thereafter substitute another Bond and surety, both of which shall eanifily with «h,. quirement^ Of Paragraphs 5.01.13must be acceptable to Owner. 5.02 Licensed Sureties and Insurers A. All Bonds and insurance required by the Contract Documents to be purchased and maintained by Owner or Design/Builder shall be obtained from surety or insurance companies that are duly licensed or authorized in the jurisdiction in which the Project is located to issue Bonds or insurance policies for the limits and coverages so required. Such surety and insurance companies shall also meet such additional requirements and qualifications as may be provided in the Supplementary Conditions. 5.03 Certificates of Insurance A. Design/Builder shall deliver to Owner, with copies to each additional insured indicated in the Supplementary Conditions, certificates of insurance (and other evidence of insurance requested by Owner or any other additional insured) which Design/Builder is required to purchase and maintain. 9viner Shall �o 5.04 Design/Builder's Liability Insurance A. Design/Builder shall purchase and maintain such liability and other insurance as is appropriate for the Work being performed and as will provide protection from claims set forth below which may arise out of or result from Design/Builder's performance of the Work and Design/Builder's other obligations under the Contract Documents, whether it is to be performed by Design/Builder, any Subcontractor or Supplier or by anyone directly or indirectly employed by any of them to perform any of the Work, or by anyone for whose acts any of them may be liable: 1. Claims under workers' compensation disability benefits and other similar employee benefit acts• 2. Claims for damaees because of bodily iiniury, occupational sickness or disease. or death of Design/Builder's emplovees: 3. Claims for damaees because of bodily injury, sickness or disease or death of any person other than Design/Builder's employ 4. Claims for damages insured by reasonably available personal iniury liability coverage which are sustained (i) by any person as a result of an offense directly or indirectly related to the employment of such person by Design/Builder. or (ii) by any other person for any other reason: 5. Claims for damages, other than to the Work itself, because of minty to or destruction of tangible property wherever located, including loss of use resulting therefrom; and 6. Claims for damages because of bodes minty or death of any person or property damage arising out of the ownership, maintenance or use of any motor vehicle B. The policies of insurance required by paragraph 5.04.A shall: 1 With respect to insurance required by paragraphs 5.04.A.3 through 5,04.A.6 inclusive 5.04 B 3 --a�.b' (subject to any customary exclusion in respect of professional liability) include as additional insureds Owner and Owner's Consultants and any other persons or entities indicated in the Supplementary Conditions all of whom shall be listed as additional insureds, and include coverage for the respective EJCDC D-700 Standard General Conditions of lira ConUael Between Owner and DosignBuilder Copynghl 02002 National Society of Professional Engineers for GJCDC. All nights reserved. Includes City of Port Collins modifications dated 09M04 11 officers directors partners and employees agents and other consultants and subcontractors of each and any of all such additional insureds, and the insurance afforded to these additional insureds shall provide primary coverage for all claims covered thereby; 2. Include at least the specific coverages and be written for not less than the limits of liability provided in the Supplementary Conditions or required by Laws or Regulations, whichever is greater• the limits of liability for the insurance required by the paragraph numbers of the General Conditions listed below are as follows: For paragraphs 5.04.A.1 and 5 04.A 2: Coverage A — Statutory limits; Coverage B -- $100000/ $100000/ $500,000. For paragraphs 5 04-A 3 and 5 04 A 5: The Commercial General Liability Policy will have limits of $1,000,000 combined single limits (CSL) This policy will include coverage for Explosions Collapse and Underground coverage unless waived by the Owner. For paragraph 5 04 A 6 The Comprehensive Automobile Liability Insurance policy will have limits of $1,000,000 combined single limits (CSL) For pars rah 5 04 B 3: This policy will include completed operations coverage / product liability coverage with limits of $1,000.000 combined single limits (CSL). This policy shall also include an Umbrella Excess Liability as follows General liability and automobile liability insurance in an amount not less than $1,000,000 per occurrence in excess of the above stated primary limits. For paragraph 5 02 C• The Professional Liabilitv Errors & Omissions poliev will have limits of $5,000,000. 3. include completed operations insurance 4. Include contractual liability insurance covering Design/Builder's-rt,a„ '-' a 5. Contain a provision or endorsement that the coverage afforded will not be canceled materially changed or renewal refused until at least thirty days' prior written notice has been given to Owner and each other additional insured indicated in the Supplementary Conditions to whom a certificate of insurance has been issued (and the certificates of insurance furnished by the Design/Builder pursuant to paragraph 5.03 will so provide); 6. Remain in effect at least until final payment and at all times thereafter when Design/Builder may be correcting, removing or replacing defective Construction in accordance with paragraphs 12 06 and 12 07; and 7 With respect to completed operations insurance, and any other insurance coverage written on a claims -made basis, remain in effect for at least two years after final payment (and Design/Builder shall furnish Owner and each other additional insured indicated in the Supplementary Conditions to whom a certificate of insurance has been issued evidence satisfactory to Owner and any such additional insured of continuation of such insurance at final payment and one year thereafter) C. Design/Builder's Professional Liability Errors & Omissions Insurance Design/Builder shall purchase and maintain such Professional Liability Errors & Omissions insurance as is appropriate for the Work being Performed and furnished and as will provide protection from claims which may arise out of or result from Design/Builder's performance and furnishing of the Work and Design/Builder's other obligations under the Contract Documents, whether it is to be performed or furnished by Design/Builder, any Subcontractor or Supplier, or by anyone directly or indirectly employed by any of them to perform or furnish any of the Work or by anyone for whose acts any of them may be liable 5.05 Owner's Liability Insurance A. In addition to the insurance required to be provided by Design/Builder under paragraph 5.04, Owner, at Owner's option, may purchase and maintain at Owner's expense Owner's own liability insurance as will protect Owner against claims which may arise from operations under the Contract Documents. 5.06 "e-ty Builders Risk Insurance A. Unless otherwise provided in the Supplementary Conditions, Owner shall purchase and maintain property insurance upon the Construction at the Site in the amount of the full replacement cost thereof (subject to such deductible amounts as may be provided in the Supplementary Conditions or required by Laws or Regulations). This insurance will: 1. Include the interests of Owner. Owner's Consultant, Design/Builder Subcontractors and any other individuals or entities indicated in the Supplementary Conditions, and the officers directors partners, employees, agents, and other consultants and subcontractors of each and any of them, each of whom is deemed to have an insurable interest and shall be listed as an insured or additional insured: 2. Be written on a Builder's Risk "all-risk" or open peril or special causes of loss policy form that shall at least include insurance for physical loss and damage to the Construction, temporary buildings falsework and all materials and equipment in transit, and shall insure against at least the following perils or causes of loss• fire, lightning extended coverage theft vandalism and IJCDC D-700 Standard General Conditions ofthe Contraot Between Owner and Desigielt0dor Copyright 62002 National Soeiety of Professional Engineers for EJCDC. All rights reserved. Includes City of Fort Collins modifications dated 09/2004 12 malicious mischief, earthquake collapse debris removal demolition occasioned by enforcement of Laws or Regulations water damage and such other perils or causes of loss as may be specifically required by the Supplementary Conditions• 3. Include expenses incurred in the repair or replacement of any insured property (including but not limited to fees and charges of engineers and architects)• 4 Cover materials and equipment stored at the Site or at another location that was agreed to in writing by Owner prior to being incorporated in the Construction, provided that such materials and equipment have been included in an Application for Payment approved by Owner 5. Allow partial utilization in accordance with paragraph 13.06� 6 Include testing and startup and 7. Be maintained in effect until final payment is made unless otherwise agreed to in writing by Owner and Design/Builder with thirty days' written notice to each other additional insured to whom a certificate of insurance has been issued. B. Owner shall purchase and maintain such boiler and machinery insurance or additional property insurance as may be required by the Supplementary Conditions or Laws or Regulations which will include the interests of Owner, Owner's Consultants, Design/Builder, Subcontractors, and any other individuals or entities indicated in the Supplementary Conditions, each of whom is deemed to have an insurable interest and shall be listed as an insured or additional insured C. All the policies of insurance (and the certificates or other evidence thereof) required to be purchased and maintained by Owner in accordance with paragraph 5.06 will contain a provision or endorsement that the coverage afforded will not be canceled or materially changed or renewal refused until at least 30 days' prior written notice has been given to Design/Builder and to each other additional insured to whom a certificate of insurance has been issued and will contain waiver provisions in accordance with paragraph 5.07. D. Owner shall not be responsible for purchasing and maintaining any property insurance to protect the interests of Design/Builder, Subcontractors, Suppliers, or others in the Work to the extent of any deductible amounts that are identified in the Supplementary Conditions. The risk of loss within such identified deductible amount, will be borne by Design/Builder, Subcontractor or others suffering any such loss and if any of them wishes property insurance coverage within the limits of such amounts, each may purchase and maintain it at the purchasers own expense. E. If Design/Builder requests in writing that other special insurance be included in the property insurance policies provided under paragraph 5.06, Owner shall, if possible, include such insurance, and the cost thereof will be charged to Design/Builder by appropriate Change Order. Prior to commencement of the Work at the Site, Owner shall in writing advise Design/Builder whether or not such other insurance has been procured by Owner. 5.07 Waiver of Rights A. Owner and Design/Builder intend that all policies purchased in accordance with paragraph 5.06 will protect Owner, Owner's Consultant, Design/Builder, Subcontractors, Suppliers, and all other individuals or entities indicated in the Supplementary Conditions to be listed as insureds or additional insureds (and the officers, directors, partners, employees, agents, and other consultants and subcontractors of each and any of them) in such policies and will provide primary coverage for all losses and damages caused by the perils or causes of loss covered thereby. All such policies shall contain provisions to the effect that in the event of payment of any loss or damage the insurers will have no rights of recovery against any of the insureds or additional insureds thereunder. Owner and Design/Builder waive all rights against each other and their respective officers, directors, partners, employees, agents, and other consultants and subcontractors of each and any of them for all losses and damages caused by, arising out of or resulting from any of the perils or causes of loss covered by such policies and any other property insurance applicable to the Work; and, in addition, waive all such rights against Owners Consultant, Subcontractors, Suppliers, and all other individuals or entities indicated in the Supplementary Conditions to be listed as insureds or additional insureds under such policies for losses and damages so caused. None of the above waivers shall extend to the rights that any party making such waiver may have to the proceeds of insurance held by Owner as trustee or otherwise payable under any policy so issued. B. Owner waives all rights against Design/Builder, Subcontractors, and Suppliers and the officers, directors, employees and agents of any of them for: 1 Loss due to business interruption loss of use or other consequential loss extending beyond direct physical loss or damage to Owner's property caused by, arising out of or resulting from fire or other peril whether or not insured by Owner; and 2 Loss or damage to the completed Project or any part thereof caused by, arising out of or resultiniz from fire or other insured peril or cause or loss covered by any property insurance maintained on the completed Project or part thereof by Owner during partial utilization pursuant to paragraph 13 06 after Substantial EJCDC D-700 Standard Genmral Conditions ofthe Contact Between Owncr and Design/Boilder Copyright 02002 National Society of Professional Engineers for EJCDC. All rights resmved. Includes City of Port Collins modifications dated 09/2004 13 Completion pursuant to paragraph 13 05 or after final payment pursuant to paragraph 13.08. C. Any insurance policy maintained by Owner covering any loss, damage or consequential loss referred to in paragraph 5.07.13 shall contain provisions to the effect that in the event of payment of any such loss, damage, or consequential loss, the insurers will have no rights of recovery against Design/Builder, Subcontractors, Owners Consultant, and the officers, directors, partners, employees, agents, and other consultants and subcontractors of each and any of them. 5.08 Receipt and Application of Insurance Proceeds A. Any insured loss under the policies of insurance required by paragraph 5.06 will be adjusted with Owner and made payable to Owner as fiduciary for the insureds, as their interests may appear, subject to the requirements of any applicable mortgage clause and of paragraph 5.08.13. Owner shall deposit in a separate account any money so received, and shall distribute it in accordance with such agreement as the parties in interest may reach. If no other special agreement is reached the damaged Construction shall be repaired or replaced, the moneys so received applied on account thereof and the Work and the cost thereof covered by an appropriate Change Order. B. Owner as fiduciary shall have power to adjust and settle any loss with the insurers unless one of the parties in interest shall object in writing within 15 days after the occurrence of loss to Owner's exercise of this power. If such objection be made, Owner as fiduciary shall make settlement with the insurers in accordance with such agreement as the parties in interest may reach. If no such agreement among the parties in interest is reached, Owner as fiduciary shall adjust and settle the loss with the insurers ^-a "required in wFitiBg J any Y interest, in Ov,HeF as fiduGiai�, shall give bond -fef the pFopeF peize._"'c^ee of suoh dtitie, 5.09 Acceptance of Bonds and Insurance; Option to Replace A. If either Owner ep-De^'^^t.,,b.mBmld� has any objection to the coverage afforded by or other provisions of the Bonds or insurance required to be purchased and maintained by the -ether -patty Design/Builder in accordance with Article 5 on the basis of their not complying with the Contract Documents, the-ehjeeting-patty Owner shall so notify the-etheiz pai Design/Builder in writing within ten fifteen (15) days after receipt of the certificates (or other evidence requested) required by paragraph 2.04.C. Owner --and De. ign, 3 .:uef shall eaGh fifevide t the ,.theF s sh additionalinfei,matign iH Fespeet of insuranee Provided as the Either may 5.10 Partial Utilization, Acknowledgment of Property Insurance A. If Owner finds it necessary to occupy or use a portion or portions of the Work prior to Substantial Completion of all the Work as provided in paragraph 13.06, no such use or occupancy shall commence before the insurers providing the property insurance pursuant to paragraph 5.06 have acknowledged notice thereof and in writing effected any changes in coverage necessitated thereby. The insurers providing the property insurance shall consent by endorsement on the policy or policies, but the property insurance shall not be canceled or permitted to lapse on account of any such partial use or occupancy. ARTICLE 6 - DESIGN/BUILDER'S RESPONSIBILITIES 6.01 Design Professional Services A. Standard of Care. The standard of care for Design Professional Services performed or furnished under this Agreement will be the care and skill ordinarily used by members of the architectural and engineering professions practicing under similar conditions at the same time and locality. B. Preliminary Design Phase. After the Contract Times commence to run, Design/Builder shall: 1. Consult with Owner to understand Owner's requirements for the Project and review available data: 2. Advise. Owner as to the necessity of Owners providing or obtaining from others additional reports data or services of the types provided in paragraph 8.01.A.6.a-g and assist Owner in obtaining such reports. data, or services 3. _ Identify and analyze requirements of governmental authorities having jurisdiction to approve the portions of the Project designed or specified by Design/Builder with whom consultation is to be undertaken in connection with the Project; 4. Obtain such additional geotechnical and related information which it deems necessary for performance of the Work: B)CDC D-700 Standard General Conditions ofthe Contract Between Owner and Desipanilder Copyright©2002 National Society of Professional Gnginecrs for rlCDC. All nitht.resetved. Includes 01y.frort Colliostnodifieatiens deted09/2004 14 11.0 DESIGN/BUILDER shall keep such full and detailed accounts as may be necessary for proper financial management under the Contract Documents with respect to all materials, equipment and labor entering into the Work. The accounting methods shall be satisfactory to OWNER. OWNER shall be afforded reasonable access to all of DESIGN/BUILDER'S records, books, correspondence, instructions, drawings, receipts, vouchers, memoranda and similar data relating to the Cost of Work and DESIGNBUILDER's Fee. DESIGN/BUILDER shall preserve all such documents for a period of three years after final payment by OWNER. Article 12. CONTRACT DOCUMENTS 12.01 The Contract Documents which comprise the entire agreement between OWNER and DESIGN/BUILDER concerning the Work consist of the following: A. This Agreement (pages 1 to 8, inclusive). B. Proposal Bond, Notice to Proceed, Performance Bond, Payment Bond, Certificate of Insurance and other documents identified as Section 00410 through 00670 consisting of fifteen (15) pages C. Standard General Conditions of the Contract Between Owner and Design/Builder (pages one to forty-one, (1-41) inclusive). D. Supplementary Conditions (pages 0800-1 to 0800-2, inclusive). E. The following, which may be delivered, prepared or issued after the Effective Date of this Agreement and are not attached hereto: All Written Amendments and other documents amending, modifying or supplementing the Contract Documents pursuant to paragraph 3.04.A of the General Conditions. 2. Specifications as defined in Paragraph 1.6I.A.40 of the General Conditions. 12.02 The documents listed in paragraph 12.01 above are attached to this Agreement (except as otherwise expressly noted). 12.03 There are no Contract Documents other than those listed above. The Contract Documents may only be amended, modified or supplemented as provided in paragraph 3.04.A of the General Conditions. 5. On the basis of the Conceptual Documents and Design/Builder's Proposal, prepare preliminary design documents consisting of final design criteria, preliminary drawings, outline specifications, and written descriptions of the Project; 6. Furnish the preliminary design documents to and review them with Owner within the times indicated in the schedules described in paragraphs 2.06.A.1 and 2.06.A2: and 7. Identify any variations in the preliminary design documents from the Contract Documents in accordance with 6.173. C. Final Design Phase. After written acceptance by Owner of the preliminary design phase documents Design/Builder shall: 1. On the basis of the accepted Preliminary Design Phase documents, prepare final Drawings showing the scope, extent, and character of the Construction to be performed and furnished by Design/Builder and Specifications (which will be prepared, where appropriate, in general conformance with the sixteen division format of the Construction Specifications Institute); 2. Provide technical criteria written descriptions and design data required for obtaining approvals of such governmental authorities as have iurisdiction to review or approve the final design of the Project and assist Owner in consultations with appropriate authorities; 3. Furnish the above documents, Drawings, and Specifications to and review them with Owner within the times indicated in the schedules described in paragraphs 2.06.A.1 and 2.06.A.2; and 4. Identify any deviations from other Contract Documents in accordance with paragraph 6.17.B. 6.02 Supervision and Superintendence of Construction A. Design/Builder shall supervise, inspect and direct the Construction competently and efficiently, devoting such attention thereto and applying such skills and expertise as may be necessary to provide the Construction in accordance with the Contract Documents. Design/Builder shall be solely responsible for the means, methods, techniques, sequences and procedures of Construction. Design/Builder shall be responsible to see that the completed Construction complies accurately with the Contract Documents and shall keep Owner advised as to the quality and progress of the Construction. B. At all times during the progress of Construction, the Design/Builder shall assign a competent resident superintendent thereto, who shall not be replaced without written notice to Owner except under extraordinary circumstances. The superintendent will be Design/Builder's representative at the Site and shall have authority to act on behalf of Design/Builder. All communications given to or received from the superintendent shall be binding on Design/Builder. 6.03 Labor, Working Hours A. Design/Builder shall provide competent, suitably qualified personnel to perform the Work as required by the Contract Documents. Design/Builder shall at all times maintain good discipline and order at the Site. B. Except as otherwise required for the safety or protection of persons or the Work or property at the Site or adjacent thereto, and except as otherwise indicated in the Contract Documents, all Construction at the Site shall be performed during rRegular wWorking #+Hours, and Design/Builder will not permit overtime work or the performance of Construction on Saturday, Sunday or any Legal hHoliday without Owner's written consent; +sh-w+4 not be unFeasena 15, withheld. DeshWBuilder shall submit requests to Owner no less than 48 hours in advance of any Work to be performed on Saturday, Sunday, Legal Holidays, or outside Regular Working Hours. 6.04 Services, Materials, and Equipment A. Unless otherwise specified in the Contract Documents, Design/Builder shall furnish or cause to be furnished and assume full responsibility for materials, equipment, labor, transportation, construction equipment and machinery, tools, appliances, fuel, power, light, heat, telephone, water, sanitary facilities, temporary facilities, and all other facilities and incidentals necessary for the Work. 1. Purchasing Restrictions: Design/Builder must comply with the City's purchasing restrictions. Copies of the resolution(s) are available for review in the offices of the Purchasing and Risk Management Division or the city Clerk's office. 2. Cement Restrictions: City of Fort Collins Resolution 91-121 requires that suppliers and producers of cement or products containing cement certify that the cement was not made in cement kilns that burn hazardous waste as a fuel. B. All materials and equipment incorporated into the Work shall be of good quality and new, except as otherwise provided in the Contract Documents. All warranties and guarantees specifically called for by the Contract Documents shall expressly run to the benefit of Owner. If reasonably required by Owner, Design/Builder shall furnish EJCDC D-700 Standard General Conditions ofihe Conlrnet Between Owner and Design/Builder Copynght 02002 National Society of Professional Engineers for EJCDC. All rights reserved. includes City of Fort Collins modifealions dated 09/2004 15 satisfactory evidence (including reports of required tests) as to the source, kind, and quality of materials and equipment. All materials and equipment shall be applied, installed, connected, erected, used, cleaned, and conditioned in accordance with instructions of the applicable Supplier, except as otherwise provided in the Contract Documents. 6.05 Progress Schedule A. Design/Builder shall adhere to the progress schedule established in accordance with paragraph 2.06.A as it may be adjusted from time to time as provided below: 1. Design/Builder shall submit to Owner for acceptance proposed adjustments in the progress schedule that will not change the Contract Times (or Milestones). Such adjustments will conform generally to the progress schedule then in effect, and will comp with any provisions of the Contract Documents applicable thereto. 2. Proposed adjustments in the progress schedule that will change the Contract Times (or Milestones) shall be submitted in accordance with the requirements of Article 11.02. Such adjustments may only be made b a Change Order. 6.06 Concerning Subcontractors, Suppliers, and Others A. Design/Builder shall not employ any Subcontractor, Supplier, or other individual or entity against whom Owner may have reasonable objection. Design/Builder shall not be required to employ any Subcontractor, Supplier or other individual or entity to furnish or perform any of the Work against whom Design/Builder has reasonable objection. Design/Builder shall perform not less than 5 percent of the Work with its own forces (that is, without subcontracting). The 20 percent requirement shall refer to the Work the value of which totals not less than 20 percent of the Contract Price. B. Design/Builder shall be fully responsible to Owner for all acts and omissions of the Subcontractors, Suppliers and other individuals or entities performing or furnishing any of the Work just as Design/Builder is responsible for Design/Builder's own acts and omissions. Nothing in the Contract Documents shall create for the benefit of any such Subcontractor, Supplier, or other individual or entity any contractual relationship between Owner and any such Subcontractor, Supplier, or other individual or entity, nor shall it create any obligation on the part of Owner to pay or to see to the payment of any moneys due any such Subcontractor, Supplier, or other individual or entity except as may otherwise be required by Laws or Regulations. C. Design/Builder shall be solely responsible for scheduling and coordinating Subcontractors, Suppliers and other individuals and entities performing or furnishing any of the Work under a direct or indirect contract with Design/Builder. The divisions and sections of the Specifications and the identifications of any Drawings shall not control Design/Builder in dividing the Work among Subcontractors and Suppliers or delineating the Work to be performed by specific trade. D. Design/Builder shall require all Subcontractors, Suppliers and such other individuals and entities performing or furnishing any of the Work to communicate with the Owner through Design/Builder. E. All Work performed for Design/Builder by a Subcontractor or Supplier will be pursuant to an appropriate Design Subagreement or Construction Subagreement between Design/Builder and the Subcontractor or Supplier which specifically binds the Subcontractor or Supplier to the applicable terms and conditions of the Contract Documents for the benefit of Owner. "'here eF any stish ^bg-eement is with Subee..t_aetaf of Suppli„« who in listed n an additional insured on the piseliefty 'Hsisitaiiee provided in paragraph 5.06F the agreementL..,t., tl.., Tl..^'..../D..ild.,_ and the SubpAntFalet8F of Supplier waives all rights against Ownef, Design/Builder, Owner's Consultant, alld all atheF additimnal _o� T any of them) for all losses and damages e sed by ^ of ahby any Subsoil or SupplieF, Pesigii/Rtiildef will ., obtainperils ef eauses of less covered by such pelieies and aH5, othe IiFepeFty insuFaaee applieable to the Wed, If the insi-FeFg en any SUGh polieies Feqiiiize sepaFate waiver terms to be signed the gAffle- 6.07 Patent Fees and Royalties A. Design/Builder shall pay all license fees and royalties and assume all costs incident to the use in the performance of the Work or the incorporation in the Work of any invention, design, process, product or device which is the subject of patent rights or copyrights held by others. If a particular invention, design, process, product, or device is specified in the Conceptual Documents for use in the performance of the Construction and if to the actual knowledge of Owner its use is subject to patent rights or copyrights calling for the payment of any license fee or royalty to others, the existence of such rights shall be disclosed by Owner in the Conceptual Documents. B. To the fullest extent permitted by Laws or Regulations, Design/Builder shall indemnify and hold harmless Owner and Owner's Consultant, and the officers, directors, partners, employees or agents, and other consultants of each and any of them from and against all claims, costs, losses and damages (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals and all court or arbitration or other dispute resolution costs) arising out of or resulting from any EICDC D-700 Standard General Conditions of the Contract Between Owner and Design/Builder Copyright ©2002 National Socicty of Professional Engineers for EICDC. All nghts reserved. Includes City of Fon Collins modifications dated 09/2004 16 infringement of patent rights or copyrights incident to the use in the performance of the Work or resulting from the incorporation in the Work of any invention, design, process, product or device not identified in the Conceptual Documents. C. To the fullest extent permitted by Laws or Regulations, Owner shall indemnify and hold harmless Design/Builder and its officers, directors, partners, employees or agents, Subcontractors and Suppliers from and against all claims, costs, losses and damages (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals and all court or arbitration or other dispute resolution costs) arising out of or resulting from any infringement of patent rights or copyrights incident to the use in the performance of the Work or resulting from the incorporation in the Work of any invention, design, process, product or device required by the Conceptual Documents. 6.08 Permits A. Unless otherwise provided in the Contract Documents, Design/Builder shall obtain and pay for all necessary permits, licenses, and approvals of governmental authorities having jurisdiction over the Work. Owner shall assist Design/Builder, when necessary, in obtaining such permits, licenses and approvals. Design/Builder shall pay all governmental charges and inspection fees necessary for the performance of the Work, which are applicable on the last day for receipt of Proposals or on the effective date of the Agreement. Design/Builder shall pay all charges of utility owners for connections to the Work, and Design/Builder shall nay fees as provided in the Supplemental Conditions. Ownee shall pay all charges of such ut I , , _elated ti.,.ren rya-.,,�.�,.o-. 6.09 Laws or Regulations A. Design/Builder shall give all notices required by and comply with all Laws or Regulations applicable to the performance of the Work. Except where otherwise expressly required by applicable Laws and Regulations, Owner shall not be responsible for monitoring Design/Builder's compliance with any Laws or Regulations. B. If Design/Builder performs any Work knowing or having reason to know that it is contrary to Laws or Regulations, Design/Builder shall bear all costs arising therefrom. C. Changes in Laws or Regulations not known on the date of receipt of Proposals having an effect on the cost or time of performance may be the subject of a change in Contract Price or Conti -act Times. 6.10 Taxes A. Design/Builder shall pay all sales, consumer, use, and other similar taxes required to be paid by Design/Builder in accordance with the Laws or Regulations of the place of the Project which are applicable during the performance of the Work. B. Owner is exempt from Colorado state and local sales and use taxes on materials to be permanently incorporated into the project. Said taxes shall not be included in the Contract Price. Design/Builder must apply for, and receive, a Certificate of Exemption from the Colorado Department of Revenue for construction materials to be physically incorporated into the project. This Certification of Exemption provides that the Design/Builder shall neither pay nor include in his Proposal, sales and use taxes on those building and construction materials physically incorporated into the project. Address: Colorado Department of Revenue State Capital Annex 1375 Sherman Street Denver, CO 80261 C. Sales and use taxes for the State of Colorado, Regional Transportation District (RTD) and certain Colorado counties are collected by the State of Colorado and are included in the Certification of Exemption. All applicable sales and use taxes (including State collected taxes) on any items other than construction and building materials physically incorporated into the project are to be paid by Design/Builder and are to be included in appropriate Work items. 6.11 Use of Site and Other Areas A. Limitation on Use of Site and Other Areas. 1. Design/Builder shall confine construction equipment, the storage of materials and equipment and the operations of construction workers to the Site and other areas permitted by Laws or Regulations, and shall not unreasonably encumber the Site and other areas with construction equipment or other materials or equipment Design/Builder shall assume full responsibility for any damage to any such land or area, or to the owner or occupant thereof or of any adjacent land or areas, resulting from the performance of the Work. 2. Should any claim be made by any such owner or occupant because of the performance of Work. Design/Builder shall promptly settle with such other party by negotiation or otherwise resolve the claim by arbitration or other dispute resolution proceeding or at law. 3. To the fullest extent permitted by Laws or Regulations. Design/Builder shall indemnify and hold harmless Owner, Owner's Consultants and and 6JCDC D-700 Stvtdard Gencral Conditions fthe Contract Between Owner and D06givBitilder Copyright 02002 National Society of Prolessional Engineers for F.JCDC. All rights resen,rd. Includes City of Pon Collins o odifieatimts dated 0912004 17 directly or indirectly employed by any of them from and against all claims, costs, losses and damages (including, but not limited to, fees of engineers, architects, attorneys and other professionals and court and arbitration or other dispute resolution costsl arising out of or resulting from any claim brought by any such owner or occupant against Owner, or any other arty indemnified hereunder to the extent caused by or based upon Design/Builder's performance of the Construction B. Removal of Debris. During the performance of the Construction, Design/Builder shall keep the premises free from accumulations of waste materials, rubbish, and other debris resulting from the Construction. Removal and disposal of such waste materials, rubbish, and other debris shall conform to applicable Laws or Regulations. C. Cleaning. Prior to Substantial Completion, Design/Builder shall clean the Site and make it ready for utilization by Owner. At completion of Construction, Design/Builder shall remove all tools, appliances, construction equipment, temporary construction and machinery, and surplus materials and shall restore to original condition all property not designated for alteration by the Contract Documents. D. Loading Structures. Design/Builder shall not load nor permit any part of any structure to be loaded in any manner that will endanger the structure, nor shall Design/Builder subject any part of the Construction or adjacent property to stresses or pressures that will endanger it. 6.12 Record Documents A. Design/Builder shall maintain in a safe place at the Site one record copy of all Drawings, Specifications, Addenda, Change Orders, Field Orders and Work Change Directives in good order and annotated to show all changes made during performance of the Work. These record documents together with all approved Submittals will be available to Owner for reference. Upon completion of the Work and prior to release of final payment, these record documents and Submittals, including a reproducible set of record drawings as provided in paragraph 3.05.D, will be delivered to Owner. 6.13 Safety and Protection A. Design/Builder shall be solely responsible for initiating, maintaining and supervising all safety precautions and programs in connection with the Work. Design/Builder shall take all necessary precautions for the safety of, and shall provide the necessary protection to prevent damage, injury, or loss to: I. All persons on the Site or who may affected by the Work; 2 All Work and materials and equipment to be incorporated therein, whether in storage on or off the Site; and 3. Other property at the Site or adjacent thereto including trees, shrubs, lawns, walks, pavements roadways, structures, utilities and underground facilities not designated for removal relocation or replacement in the course of construction. B. Design/Builder shall comply with applicable Laws or Regulations relating to the safety of persons or property, or to the protection of persons or property from damage, injury, or loss; and shall erect and maintain all necessary safeguards for such safety and protection. Design/Builder shall notify owners of adjacent property and of underground facilities and utility owners when prosecution of the Work may affect them, and shall cooperate with them in the protection, removal, relocation, and replacement of their property. C. All damage, injury, or loss to any property referred to in paragraph 6.13.A.2 or 6.13.A.3 caused, directly or indirectly, in whole or in part, by Design/Builder, any Subcontractor, Supplier, or any other individual or entity directly or indirectly employed by any of them to perform any of the Work, or anyone for whose acts any of them may be liable, shall be remedied by Design/Builder. D. Design/Builder's duties and responsibilities for safety and for protection of the construction shall continue until such time as all the Work is completed and Owner has issued a notice to Design/Builder in accordance with paragraph 13.08.B that the Work is acceptable (except as otherwise expressly provided in connection with Substantial Completion). 6.14 Safety Representative A. Design/Builder shall designate a qualified and experienced safety representative at the Site whose duties and responsibilities shall be the prevention of accidents and the maintaining and supervising of safety precautions and programs. 6.15 Hazard Communication Programs A. Design/Builder shall be responsible for coordinating any exchange of material safety data sheets or other hazard communication information required to be made available to or exchanged between or among employers at the Site in accordance with Laws or Regulations. IJCDC D-700 Standard Gcncral Conditions ofdm Contract netwecn Owner mid Design/Boilder Copyright 02002 Nelional Socicty of Profession¢I rngmn ors for EJCDC All rights roso,v d. Includes City of Fort Collins,wdifieatione dated 09/2004 18 6.16 Emergencies A. In emergencies affecting the safety or protection of persons or the Work or property at the Site or adjacent thereto, Design/Builder is obligated to act to prevent threatened damage, injury or loss. Design/Builder shall give Owner prompt written notice if Design/Builder believes that any significant changes in the Work or variations from the Contract Documents have been caused thereby or are required as a result thereof. If a change in the Contract Documents is required because of the action taken by Design/Builder in response to such an emergency, a Work Change Directive or Change Order will be issued. 6.17 Submittals A. Owner will review and approve Submittals in accordance with the schedule of required Submittals accepted by Owner as required by paragraph 2.06.A. Owner's review and approval will be only to determine if the items covered by the Submittals will, after installation or incorporation in the construction, conform to the information given in the Contract Documents and be compatible with the design concept of the completed Project as a functioning whole as indicated by the Contract Documents. Owner's review and approval will not extend to means, methods, techniques, sequences, or procedures of construction (except where a particular means, method, technique, sequence, or procedure of construction is specifically and expressly called for by the Contract Documents) or to safety precautions or programs incident thereto. The review and approval of a separate item as such will not indicate approval of the assembly in which the item functions. B. Owner's review and approval of Submittals shall not relieve Design/Builder from responsibility for any variation from the requirements of the Contract Documents unless Design/Builder has in a separate written communication at the time of submission called Owner's attention to each such variation and Owner has given written approval. C. Construction prior to Owner's review and approval of any required Submittal will be at the sole risk of Design/Builder. 6.18 Continuing the Work A. Design/Builder shall continue the Work and adhere to the progress schedule during all disputes or disagreements with Owner. No Work shall be delayed or postponed pending resolution of any disputes or disagreements, except as Design/Builder and Owner may otherwise agree in writing. 6.19 Post -Construction Phase A. Design/Builder shall: 1. Provide assistance in connection with the start-up, testing, refining and adjusting of anyequipment or system. 2. Assist Owner in training staff to operate and maintain the Work. 3. Assist Owner in developing systems and procedures for control of the operation and maintenance of and record keeping for the Work. 6.20 Design/Builder's General Warranty and Guarantee A. Design/Builder warrants and guarantees to Owner that all @enstwctiee Work will be in accordance with the Contract Documents and will not be defective. Design/Builder's warranty and guarantee hereunder excludes defects or damage caused by: I. Abuse- modification or improper maintenance or operation by persons other than Design/Builder, Subcontractors, or Suppliers or any other individual for whom Design/Builder is responsible, unless such abuse, modification, or improper maintenance or operation was permitted by or could reasonably have been prevented by Design/Builder, Subcontractors or Suppliers: or 2. Normal wear and tear under normal usage B. Design/Builder's obligation to perform and complete the Work in accordance with the Contract Documents shall be absolute. None of the following will constitute an acceptance of Work that is not in accordance with the Contract Documents or a release of Design/Builder's obligation to perform the Work in accordance with the Contract Documents: I_ Observations by Owner: 2. The making of any progress or final payment: 3. The issuance of a certificate of Substantial Completion or any paymenty Owner to Design/Builder under the Contract Documents: 4. Use or occupancy of the Work or any part thereof by Owner: SO" 5. Any acceptance by Owner or any failure to do E1CDC D400 Siandard General Condiliens of the Contract Between Owner and Design/Builder Copyright V2002 National Socicq, of Profcssionel Engineers for E1CDC All rights rcw,wd, Includes City of Fat Collins modifications dated 09/2004 19 6. —Any review and approval of a Submittal: 7. Any inspection, test or approval by others or 8. Any correction of defective Garistfuetiee Work by Owner. 6.21 Indemnification A. To the fullest extent permitted by Laws or Regulations, Design/Builder shall indemnify and hold harmless Owner, Owner's Consultants, and the officers, directors, partners, employees, agents, other consultants and subcontractors of each from and against all claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals and all court or arbitration or other dispute resolution costs) arising out of or resulting from the performance of r ongtFu ien the Work, provided that any such claim, cost, loss, or damage is attributable to bodily injury, sickness, disease, or death, or to injury to or destruction of tangible property (other than the Work itself), including the loss of use resulting therefrom ` only and is caused in whole or in Dart by any negligent act or omission of Design/Builder, any Subcontractor, any Supplier, or any individual or entity directly or indirectly employed by any of them to perform or furnish any of the Work or anyone for whose acts any of them may be liable, regardless of whether or not caused in part by any negligence or omission of an individual or entity indemnified hereunder or whether liability is imposed upon such indemnified party by Laws and Regulations regardless of the negligence of any such individual or entity. B. In any and all claims against Owner, Owner's Consultant or any of their respective consultants, agents, officers, directors, partners or employees by any employee (or the survivor or personal representative of such employee) of Design/Builder, any Subcontractor, any Supplier, any individual or entity directly or indirectly employed by any of them to perform any of the Work or anyone for whose acts any of them may be liable, the indemnification obligation under paragraph 6.21.A shall not be limited in any way by any limitation on the amount or type of damages, compensation or benefits payable by or for Design/Builder or any such Subcontractor, Supplier, or other individual or entity under workers' compensation acts, disability benefit acts or other employee benefit acts. C. The indemnification obligations of Design/Builder under paragraph 6.2LA shall not extend to the liability of Owner's Consultant, and their officers, directors, partners, employees, agents, other consultants, and subcontractors arising out of the preparation or approval of maps, drawings, opinions, reports, surveys, designs, or specifications. 6.22 Survival of Obligations A. All representations, indemnifications warranties and guarantees made in required by or given in accordance with the Contract Documents as well as all continuing obligations indicated in the Contract Documents will survive final payment completion and acceptance of the Work and termination or completion of the Agreement. ARTICLE 7 — OTHER CONSTRUCTION 7.01 Related Work at Site A. Owner may perform other Work related to the Project at the Site by Owner's employees, or let other direct contracts therefor, or have other work performed by utility owners. If such other work is not noted in the Contract Documents, then: 1. Written notice thereof will be given to Design/Builder prior to starting any such other work: and 2. Design/Builder may make a Claim therefor as provided in Article 9 if Design/Builder believes that such performance will involve additional expense to Design/Builder or requires additional time and the parties are unable to agree as to the amount or extent thereof B. Design/Builder shall afford each other contractor who is a party to such a direct contract and each utility owner (and Owner, if Owner is performing the additional work with Owner's employees) proper and safe access to the Site and a reasonable opportunity for the introduction and storage of materials and equipment and the execution of such other work and shall properly connect and coordinate the Work with theirs. Unless otherwise provided in the Contract Documents, Design/Builder shall do all cutting, fitting, and patching of the Work that may be required to make its several parts come together properly and integrate with such other work. Design/Builder shall not endanger any work of others by cutting, excavating, or otherwise altering their work and will only cut or alter their work with the written consent of Owner and the others whose work will be affected. The duties and responsibilities of Design/Builder under this paragraph are for the benefit of such utility owners and other contractors to the extent that there are comparable provisions for the benefit of Design/Builder in said direct contracts between Owner and such utility owners and other contractors. C. If the proper execution or results of any part of Design/Builder's Work depends upon work performed or services provided by others under this Article 7, Design/Builder shall inspect such other work and appropriate instruments of service and promptly report to Owner in writing any delays, defects or deficiencies in such other work CJCDC D-700 Standard Geocrel Conditions fthe Contract Betwoon Owncr and Design/Builder Copyright02002 National Society of Professional Ggineen for EJCDC. All tights reserved. Includes City of Fort Collins modifications da1cd 09/2004 20 or services that render it unavailable or unsuitable for the proper execution and results of Design/Builder's Work. Design/Builders failure so to report will constitute an acceptance of such other work as fit and proper for integration with Design/Builder's Work except for latent or nonapparent defects and deficiencies in such other work. 7.02 Coordination A. If Owner intends to contract with others for the performance of other work on the Project at the Site, the following will be set forth in Supplementary Conditions: 1. The individual or entity who will have authority and responsibility for coordination of the activities among the various Prime contractors will be identified 2. The specific matters to be covered by such authority and responsibility will be itemized: and 3 The extent of such authority and responsi- bilities will be provided. B. Unless otherwise provided in the Supplementary Conditions, Owner shall have sole authority and responsibility in respect of such coordination. ARTICLE 8 — OWNER'S RESPONSIBILITIES 8.01 General A. Owner shall do the following in a timely manner so as not to delay the services of Design/Builder: 1. Designate in writing a person to act as Owner's Representative with respect to the services to be rendered under this Agreement Such person shall have complete authority to transmit instructions, receive information, interpret and define Owner's policies, make decisions with respect to performance of the Work, and shall provide such other services as may be agreed upon 2. Provide such legal services as Owner may require with regard to legal issues pertaining to the Project including any that may be raised by Design/Builder; 3. If requested in writing by Design/Builder, furnish reasonable evidence satisfactory to Design/Builder that sufficient funds are available and committed for the entire cost of the Project Unless such reasonable evidence is furnished. Design/Builder is not required to commence or continue any Work, or may, if such evidence is not presented within a reasonable time stop Work upon 15 days notice to the Owner: 4. Make payments to Design/Builder romRtly when they are due as provided in paragraph 13.03 and 13_08 5. Furnish the Site as set forth in paragraph 4.01.A 6. Furnish to Design/Builder, as required for performance of Design/Builder's Services the following, all of which Design/Builder may use and rely upon in performing services under this Agreement a. Environmental assessment and impact statements; b. Property, boundary, easement, right-of- way, topographic, and utility surveys; C. Property descriptions; d. Zoning, deed, and other land use re- strictions; e. Engineering surveys to establish reference points for design and construction which in Owner's judgment are necessary to enable Design/Builder to proceed with the Work; f. Assistance to Design/Builder in filing documents required to obtain necessary permits, licenses, and approvals of governmental authorities having jurisdiction over the Project; g. Permits, licenses, and approvals of government authorities Owner is specifically required to obtain by the Contract Documents; and h. All subsurface data at or contiguous to the Site which Owner may have obtained. 7. Review Submittals subiect to Owner review pursuant to paragraph 6.17.A: and 8. Provide information known to or in the possession of Owner relating to the presence of materials and substances at the Site which could create a Hazardous Environmental Condition. 8.02 Insurance A. Owner's responsibilities in respect of purchasing and maintaining liability and property insurance are set forth in Article 5. WCDC D-700 Standard Oenoml Conditions of the Contact Between Ownor and Duiga/Bailder Copyright 02002 National Society of Profcssional Engineers for E1CDC. All rights reserved. Inolades City of Port Collins modifications dated 09/2004 21 8.03 Limitations on Owner's Responsibilities A. The Owner shall not supervise, direct, or have control or authority over, nor be responsible for, Design/Builders means, methods, techniques, sequences, or procedures of construction or the safety precautions and programs incident thereto, or for any failure of Design/Builder to comply with Laws or Regulations applicable to the furnishing or performance of the Work. Owner will not be responsible for Design/Builder's failure to perform the Work in accordance with the Contract Documents. 8.04 Undisclosed Hazardous Environmental Condition A. Owner's responsibility in respect of undisclosed Asbestos, PCBs, Petroleum, Hazardous Waste, or Radioactive Materials uncovered or revealed at the Site is set forth in paragraph 4.04. 8.05 Resident Project Representation A. Owner may furnish a Resident Project Representative to observe the performance of Construction. The duties, responsibilities and limitations of authority of any such Resident Project Representative and assistants will be as provided in the Supplementary Conditions. 8.06 Owner's Consultant A. Owner's Consultant, if any, has no duties, responsibilities, or authorities with respect to Design/Builder, unless so provided in the Supplementary Conditions. ARTICLE 9 — CHANGES IN THE WORK; CLAIMS 9.01 Authorized Changes in the Work A. Without invalidating the Agreement and without notice to any surety, Owner may, at any time or from time to time, order additions, deletions, or revisions in the Work ,, a'w..z hip-^ ",one-^' scope of the "^..t a^ by a Written Amendment, Change Order or a Work Change Directive. Upon receipt of any such document, Design/Builder shall promptly proceed with the Work involved which will be performed under the applicable conditions of the Contract Documents (except as otherwise specifically provided). 9.02 Unauthorized Changes in the Work A. Design/Builder shall not be entitled to an increase in the Contract Price or an extension of the Contract Times with respect to any Work performed that is not required by the Contract Documents as amended, modified and supplemented as provided in paragraph 3.04, except in the case of an emergency as provided in paragraph 6.16 or in the case of uncovering Construction as provided in paragraph 12.04. 9.03 Claims A. Notice. If Owner and Design/Builder are unable to agree on entitlement to, or on the amount or extent, if any, of an adjustment in the Contract Price or an adjustment of the Contract Times that should be allowed as a result of any order of Owner pursuant to paragraph 9.0 LA or other occurrence for which the Contract Documents provide that such adjustment(s) may be made, a Claim may be made therefor. Written notice of intent to make such a Claim shall be submitted to the other party promptly and in no event more than 15 days after the start of the occurrence or event giving rise tothe Claim. B. Documentation. Substantiating documentation shall be submitted by the claiming party within 30 days after delivery of the notice required by paragraph 9.03.A. C. Decision. The other party shall render a decision on the Claim no more than 30 days after the receipt of the substantiating documentation required by paragraph 9.03.13. This decision will be final and binding unless the claiming party gives notice of intention to exercise its rights under Article 15 within 30 days of receipt of the decision and exercises such rights within 30 days of giving the notice of intent. D. Time Limit Extension. The time limits of paragraphs 9.03.13 and 9.03.0 may be extended by mutual agreement. 9.04 Execution of Change Orders A. Owner and Design/Builder shall execute appropriate Change Orders covering: I. Changes in the Work which are (i) ordered by Owner pursuant to paragraph 9.01, (ii) required because of acceptance of defective Construction or Work under paragraph 12.08 or Owners correction of defective Construction or Work under paragraph 12.09 or (iii) agreed to by the parties: and 2. Changes in the Contract Price or Contract Times which are agreed to by the parties, including any undisputed sum or amount of time for Work actuate performed in accordance with a Work Change Directive-: provided that, in lieu of executing any such Change Order, an appeal may be taken from any such decision in accordance with the provisions of the Contract Documents and applicable Laws and Regulations, but during any such appeal Design/Builder shall earry on the EICDC D-900 Standard General Conditions fthe Contract newcen Owner and Desitn /milder Copyright 02002 National Society of Professional Gtginees for EICDC. All rights reserved. Includes City of Fort Collins modifications dated 09/2004 22 Work and adhere to the progress schedule as provided in paragraph 6.18. 9.05 Notice to Sureties A. if notice of any change affecting the general scope of the Work or the provisions of the Contract Documents (including, but not limited to, Contract Price or Contract Times) is required by the provisions of any Bond to be given to a surety, the giving of any such notice will be Design/Builder's responsibility. The amount of each applicable Bond will be adjusted to reflect the effect of any such change. 9.06 Effect of Change Orders A. By the execution of a Change Order, a Work Change Directive, or Written Agreement, Owner and Design/Builder expressly acknowledge and agree that said Change Order, Work Change Directive, or Written Agreement provides for a fair and equitable adjustment in Contract Price and/or Contact Time for the additions, deletions, or revisions in the Work as authorized by said Change Order, Work Change Directive or Written Agreement. Owner and Design/Builder further expressly acknowledge and agree that claims for adjustments to the Contract Price and/or Contract Time covered by a Change Order, Work Change Directive or Written Agreement are not valid. ARTICLE 10 — COST OF THE WORK; CASH ALLOWANCES; UNIT PRICE WORK 10.01 Cost of the Work A. Costs Included. The term Cost of the Work means the sum of all costs necessarily incurred and paid by Design/Builder in the proper performance of the Work. When the value of Work covered by a Change Order or when a Claim for an adjustment in Contract Price is determined on the basis of Cost of the Work, the costs to be reimbursed to Design/Builder will be only those additional or incremental costs required because of the change of the Work or because of the event giving rise to the Claim. Except as otherwise may be agreed to in writing by Owner, such costs shall be in amounts no higher than those prevailing in the locality of the Project, shall include only the following items, and shall not include any of the costs itemized in paragraph 10.01.13: 1. Payroll costs for employees in the direct employ of Design/Builder in the performance of the Work under schedules of job classifications agreed upon by Owner and Design/Builder. a. Such employees shall include without limitation superintendents, foremen, and other personnel employed full-time at the Site. Payroll costs for employees not employed full time on the Work shall be apportioned on the basis of their time spent on the Work. Payroll costs shall '^^ludo, b,.^ ' u net -be limited to, salaries and wages plus the cost of fringe benefits which shall include social security contributions, unemployment, excise and payroll taxes, workers' compensation, and health and ,..rent benefits, bonuses,a holiday pay applicable thereto. The expenses of performing Work after regular working hours, on Saturday, Sunday or ILegal #Holidays, shall be included in the above to the extent authorized by Owner. b. Such employees shall also include engineers, engineering technicians, architects, and others providing Design Professional Services. For purposes ofthis paragraph 10.0l.A.1, Design/Builder shall be entitled to payment for such employees an amount equal to salary costs times a factor, both as designated in the Agreement, for all services performed or furnished by such employees engaged on the Project. 2. Cost of all materials and equipment furnished and incorporated in the Work, including costs of transportation and storage thereof, and Suppliers' field services required in connection therewith All cash discounts shall accrue to Design/Builder unless Owner deposits funds with Design/Builder with which to make payments, in which case the cash discounts shall accrue to Owner. All trade discounts, rebates and refunds and returns from sale of surplus materials and equipment shall accrue to Owner. and Design/Builder shall make provisions so that they may be obtained 3. Payments made by Design/Builder to Subcontractors (excluding payments for Design Professional Services pursuant to paragraph 10 0l.A 4) for Work performed or furnished by Subcontractors If any subcontract provides that the Subcontractor is to be paid on the basis of Cost of the Work plus a fee. the Subcontractor's Cost of the Work and fee shall be determined in the same manner as Design/Builder's Cost of the Work and fee. All subcontracts shall be subject to the other provisions of the Contract Documents insofar as applicable. 4. Payments made by Design/Builder for Design Professional Services provided or furnished under a Design Subagreement. 5. Costs of special consultants (including but not limited to testing laboratories, surveyors, attorneys, and E1CDC D-700 Standard General Conditimu ofthe Contract Between owner and Design/Builder Copyright 02002 National Society of Brotessional 8ngincecs for E1CDC. All rights reserved. Incledca City of Port Collins modifications dated 09/2004 23 accountants) employed for services specifically related to the Work. 6. Supplemental costs including the following items: a. The proportion of necessary transporta- tion, travel and subsistence expenses of Design/Builder's employees incurred in discharge of duties connected with the Work. b. Cost, including transportation and maintenance, of all materials, supplies, equipment, machinery, appliances, office and temporary facilities at the Site and hand tools not owned by the workers, which are consumed in the performance of the Work, and cost, less market value, of such items used but not consumed which remain the property of Design/Builder. C. Rentals of all construction or engineering equipment and machinery and the palls thereof whether rented from Design/Builder or others in accordance with rental agreements approved by Owner, and the costs of transportation, loading, unloading, installation, dismantling and removal thereof. All such costs shall be in accordance with the terms of said rental agreements. The rental of any such equipment, machinery or parts shall cease when the use thereof is no longer necessary for the Work. d. Sales, consumer, use, and other similar taxes related to the Work, and for which Design/Builder is liable, imposed by Laws or Regulations. e. Deposits lost for causes other than negligence of Design/Builder, any Subcontractor or anyone directly or indirectly employed by any of them or for whose acts any of them may be liable, and royalty payments and fees for permits and licenses. f. Losses, damages, and related expenses caused by damage to the Work not compensated by insurance or otherwise, sustained by Design/Builder in connection with the furnishing and performance of the Work (except losses and damages within the deductible amounts of property insurance established by Owner in accordance with Article 5 above) provided they have resulted from causes other than the negligence of Design/Builder, any Subcontractor, or anyone directly or indirectly employed by any of them or for whose acts any of them may be liable. Such losses shall include settlements made with the written consent and approval of Owner. No such losses, damages, and expenses shall be included in the Cost of the Work for the purpose of determining Design/Builder's fee. g. The cost of utilities, fuel, and sanitary facilities at the Site. h. Minor expenses such as telegrams, long distance telephone calls, telephone service at the Site, expressage, and similar petty cash items in connection with the Work. i. Cost of premiums for all Bonds and insurance Design/Builder is required by the Contract Documents to purchase and maintain. B. Costs Excluded. The term Cost of the Work shall not include any of the following items: 1. Payroll costs and other compensation of Design/Builder's officers, executives, principals (of partnerships and sole proprietorships), general managers, engineers, architects, estimators, attorneys, auditors, accountants, purchasing and contracting agents, expediters, timekeepers, clerks and other personnel employed by Design/Builder whether at the Site or in Design/Builder's principal or a branch office for general administration of the Work and not specifically included in the agreed upon schedule of job classifications referred to in paragraph 10.0l.A.1, all of which are to be considered administrative costs covered by the Design/Builder's fee. 2. Expenses of Design/Builders principal and branch offices other than Design/Builder's office at the Site. 3. Any part of Design/Builder's capital expenses, including interest on Design/Builder's capital employed for the Work and charges against Design/Builder for delinquent payments. 4. Costs due to the negligence of Design/Builder, any Subcontractor, or anyone directly or indirectly employed by any of them or for whose acts any of them may be liable, including but not limited to the correction of defective Work, disposal of materials or equipment wrongly supplied, and making good any damage to property. 5. Other overhead or general expense costs of any kind and the costs of any item not specifically and expressly included in paragraph 10.01.A. W CDC. D-900 Standard General Conditions of the C.w o nclweco Owner and Design/milder Copyright 622002 National Socicty or professional Engineers for EJCDC. All nghts o,.,c . ).erodes City ofport Collins modifications dated 09/2004 24 12.04 In the case of any irreconcilable ambiguity, inconsistency or conflict between DESIGN/BUILDER's Proposal and the Request for Proposal , the terns of the Proposal shall be controlling. Article 13. MISCELLANEOUS 13.01 The Standard General Conditions of the Contract Between Owner and Design/Builder are referred to herein as the General Conditions. 13.02. Terms used in this Agreement will have the meanings indicated in Article I of the General Conditions. 13.03 No assignment by a party hereto of any rights under or interests in the Contract Documents will be binding on another party hereto without the written consent of the party sought to be bound; and, specifically but without limitation, moneys that may become due and moneys that are due may not be assigned without such consent (except to the extent that the effect of this restriction may be limited by law), and unless specifically stated to the contrary in any written consent to an assignment no assignment will release or discharge the assignor from any duty or responsibility under the Contract Documents. 13.04 OWNER and DESIGN/BUILDER each binds itself, its partners, successors, assigns and legal representatives to the other party hereto, its partners, successors, assigns and legal representatives in respect to all covenants, agreements and obligations contained in the Contract Documents. 13.05. Any provision or part of the Contract Documents held to be void or unenforceable under any Law or Regulation shall be deemed stricken, and all remaining provisions shall continue to be valid and binding upon OWNER and DESIGN/BUILDER, who agree that the Contract Documents shall be reformed to replace such stricken provision or part thereof with a valid and enforceable provision that comes as close as possible to expressing the intention of the stricken provision. 13.06 The Contract Documents shall constitute public records under the Colorado Public Records Act, and shall be available for public review upon request, except for the Audited Financial Statement of DESIGN/BUILDER included in DESIGN/BUILDER'S Proposal. IN WITNESS WHEREOF, OWNER and DESIGN/BUILDER have signed this Agreement in duplicate. One counterpart each has been delivered to OWNER and DESIGN/BUILDER. All portions of the Contract Documents have been signed, initiated or identified by OWNER and DESIGN/BUILDER. This Agreement will be effective on May 5, 2008. 11 C. DesignlBuilder's Fee. When all the Work is performed on the basis of cost-plus, Design/Builder's fee shall be as set forth in the Agreement. When the value of the Work covered by a Change Order is determined on the basis of Cost of the Work, Design/Builder's fee shall be determined as set forth in paragraph l I.01.C. D. Documentation. Whenever the cost of any Work is to be determined pursuant to paragraph 10.0l.A and 10.01.B, Design/Builder will establish and maintain records thereof in accordance with generally accepted accounting practices and submit in a form acceptable to Owner an itemized cost breakdown together with supporting data. 10.02 Cash Allowances A. The Contract Price includes all allowances so named in the Contract Documents. Design/Builder shall cause the Work so covered to be performed for such sums as may be acceptable to Owner. Design/Builder agrees that: 1. The allowances include the cost to Design/Builder (less any applicable trade discounts) of materials and equipment required by the allowances to be delivered at the Site and all applicable taxes and 2. Except as set forth in the Contract Documents Design/Builder's costs for unloading and handling on the Site, labor, installation costs overhead profit and other expenses contemplated for the allowances have been included in the Contract Price and not in the allowances and no demand for additional payment on account of any of the foregoing will be valid B. Prior to final payment, an appropriate Change Order will be issued to reflect actual amounts due Design/Builder on account of Work covered by allowances, and the Contract Price shall be correspondingly adjusted. 10.03 Unit Prices A. Where the Contract Documents provide that all or part of the Work is to be Unit Price Work, initially the Contract Price will be deemed to include for all of Unit Price Work an amount equal to the sum of the established unit prices for each separately identified item of Unit Price Work times the estimated quantity of each item as indicated in the Agreement. The estimated quantities of items of Unit Price Work are not guaranteed and are solely for the purpose of comparison of Bids and determining an initial Contract Price. Determinations of the actual quantities and classifications of Unit Price Work performed by Design/Builder will be made by Owner. B. Each unit price will be deemed to include an amount considered by Design/Builder to be adequate to cover Design/Builder's overhead and profit for each separately identified item. C. Design/Builder or Owner may make a Claim for an adjustment in the Contract Price in accordance with Article 9 if 1. the quantity of any item of Unit Price Work performed by Design/Builder differs materially and significantly from the estimated quantity of such item indicated in the Contract Docume 2. there is no corresponding adjustment with respect to any other item of Work; and 3. Design/Builder believes that it is entitled to an increase in Contract Price as a result of having incurred additional expense or Owner believes it is entitled to a decrease in Contract Price and the parties are unable to agree as to the amount of any such increase or decrease D. Design/Builder acknowledges that Owner has the right to add or delete items of the Work or change quantities at Owner's sole discretion without affecting the Contract Price of any remaining item so longas s the deletion or addition does not exceed twenty-five nercent of the estimated quantity of the item ARTICLE 11 — CHANGE OF CONTRACT PRICE; CHANGE OF CONTRACT TIMES 11.01 Change of Contract Price A. The Contract Price may only be changed by a Change Order or by a Written Amendment. Any Claim for an adjustment in the Contract Price shall be based on written notice delivered by the party making the Claim to the other party promptly in accordance with paragraph 9.03.A. B. The value of any Work covered by a Change Order or of any Claim for an adjustment in the Contract Price will be determined as follows: I. Where the Work involved is covered by unit prices contained in the Contract Documents by application of such unit prices to the quantities of the items involved (subject to the Provisions of paragraph J0.0R or 2. Where the Work involved is not covered by unit prices contained in the Contract Documents bya mutually agreed payment basis including loom sum (which may include an allowance for overhead and profit EJCDC D-900 Standard General Conditions ofthe Contract Between Owner and Design/milder Copyright Q2002 National Society of Professional Engineers for EJCDC, All rights reserved. Inelades City of Fort Collins modifications dated 09/2004 25 not necessarily in accordance with paragraph 11 0] C.21 or 3 Where the Work involved is not covered -by unit prices contained in the Contract Documents and agreement to a lump sum is not reached under paragraph 11.01.13.2 on the basis of the Cost of the Work (determined as provided in paragraph 1001) plus a Design/Builder's Fee for overhead and profit (determined as provided in paragraph 11.01.0 C. Design/Builders Fee: The Design/Builder's fee for overhead and profit on Change Orders shall be determined as follows: 1. A mutually acceptable fixed fee: or 2. If a fixed fee is not agreed upon, then a fee based on the following_ percentages of the various portions of the Cost of the Work: a. For costs incurred under paragraphs 10.01.A.l.a and 10.01.A.2, the Design/Builder's fee shall be 43 three percent; b. For costs incurred under paragraph 10.01.A.3 10.0l.A.4, 10.01.A.5 and 10.0l.A.6, the Design/Builder's fee shall be €we three percent; C. Where one or more tiers of subcontracts are on the basis of Cost of the Work plus a fee and no fixed fee is agreed upon, the intent of paragraphs 11.0l.C.1 and 11.0l.C.2.a is that the Subcontractor who actually performs or furnishes Work, at whatever tier, will be paid a fee of 15 percent of the costs incurred by such Subcontractor under paragraphs 10.01.A.1 and 10.01.A.2 and that any higher tier Subcontractor and Design/Builder will each be paid a fee 4 to be negotiated in good faith with Owner but not to exceed five percent of the amount paid to the next lower tier Subcontractor; d. The amount of credit to be allowed by Design/Builder to Owner for any change which results in a net decrease in cost will be the amount of the actual net decrease in cost plus a deduction in Design/Builder's fee by an amount equal to five three percent of such net decrease; and e. When both additions and credits are involved in any one change, the adjustment in Design/Builder's fee shall be computed on the basis of the net change in accordance with paragraphs 11.0l.C.2.a through I1.0l.C.2.d, inclusive. f. No fee shall be pavable on the basis of costs itemized under paragraphs 10,01.A.5, 10.0l.A.6 or 10.01 B. 11.02 Change of Contract Times A. The Contract Times (or Milestones) may only be changed by a Change Order. Any Claim for an adjustment of the Contract Times (or Milestones) shall be based on written notice pursuant to paragraph 9.03.A. B. Delays Beyond DesignIBuilder's Control. Where Design/Builder is prevented from completing any part of the Work within the Contract Times (or Milestones) due to delay beyond the control of Design/Builder, the Contract Times (or Milestones) will be extended in an amount equal to the time lost due to such delay if a Claim is made therefor as provided in paragraph 11.02.A. Delays beyond the control of Design/Builder shall include, but not be limited to, acts or neglect by Owner, governmental agencies, acts or neglect of utility owners or other contractors performing other construction work as contemplated by Article 7, fires, floods, epidemics, abnormal weather conditions, or acts of God. C. If Owner or other contractor or utility owners performing other work for Owner as contemplated by Article 7, or anyone for whom Owner is responsible, delays, disrupts, or interferes with the performance or progress of the Work, then Design/Builder shall be entitled to an equitable adjustment in the Contract Price or the Contract Times, or both. Design/Builder's entitlement to an adjustment of the Contract Times is conditioned on such adjustment being essential to Design/Builder's ability to complete the Work within the Contract Times. D. If Design/Builder is delayed in the performance or progress of the Work by fire, flood, epidemic, abnormal weather conditions, acts of God, acts or failures to act of utility owners not under the control of Owner, or other causes not the fault of and beyond control of Owner and Design/Builder, then Design/Builder shall be entitled to an equitable adjustment in Contract Times, if such adjustment is essential to Design/Builder's ability to complete the Work within the Contract Times. Such an adjustment shall be YJCDC D400 Standard Goreral Conditions ofthe Contract Between Owner and DesigNnnilder Copyright 02002 National Society of Professional Hngineers for E.ICDC. All rights reserved. Includes City of Fort Collins modifications doled 09/2004 26 Design/Builder's sole and exclusive remedy for the delays described in this Paragraph 11.02.D. E. Owner and Owner's Consultant shall not be liable to Design/Builder for any claims, costs, losses, or damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) sustained by Design/Builder on or in connection with any other project or anticipated project. F. Design/Builder shall not be entitled to an adjustment in Contract Price or Contract Times for delays within the control of Design/Builder. Delays attributable to and within the control of a Subcontractor or Supplier shall be deemed to be delays within the control of Design/Builder. ARTICLE 12 — TESTS AND INSPECTIONS; CORRECTION, REMOVAL OR ACCEPTANCE OF DEFECTIVE CONSTRUCTION OR WORK 12.01 Notice of Defects A. Owner shall give Design/Builder prompt written notice of all defective Construction or Work of which Owner has actual knowledge. All defective Construction or Work may be rejected, corrected or accepted as provided in this Article 12. 12.02 Access to Construction A. Owner, Owner's Consultants, other representatives and personnel of Owner, independent testing laboratories and governmental agencies with jurisdictional interests will have access to the Site and the Construction at reasonable times for their observation, inspecting, and testing. Design/Builder shall provide them proper and safe conditions for such access and advise them of Design/Builder's Site safety procedures and programs so that they may comply therewith as applicable. 12.03 Tests and Inspections A. If the Contract Documents or Laws or Regulations of any public body having jurisdiction require any part of the Geristfuetion Work specifically to be inspected, tested or approved, Design/Builder shall assume full responsibility for arranging and obtaining such inspections, tests or approvals, pay all costs in connection therewith, and furnish Owner the required certificates of inspection or approval. Design/ Builder shall also be responsible for arranging and obtaining and shall pay all costs in connection with any inspections, tests, or approvals required for Owner's acceptance of materials or equipment to be incorporated in the Work or of materials, mix designs, or equipment submitted for approval prior to Design/Builder's purchase thereof for incorporation in the Work. B. Design/Builder shall give Owner reasonable notice of the planned schedule for all required inspections, tests, or approvals. C. If any Construction (or the construction work of others) that is required to be inspected, tested, or approved is covered by Design/Builder without written concurrence of Owner, it must, if requested by Owner, be uncovered for observation at Design/Builder's expense unless Design/ Builder has given Owner timely notice of Design/Builder's intention to cover the same and Owner has not acted with reasonable promptness in response to such notice. D. Owner shall employ and pay for the services of an independent testing laboratory to perform all inspections, tests, or approvals required by the Contract Documents except (i) for inspections, tests, or approvals covered by paragraph 12.03.A above; (ii) costs incurred in connection with tests or inspections conducted pursuant to paragraph 12.04.13 below shall be paid as provided in said paragraph 12.04.13; and (iii) as otherwise specifically provided in the Contract Documents. 12.04 Uncovering Construction A. If any Construction is covered contrary to the written request of Owner, it must, if requested by Owner, be uncovered for Owner's observation and recovered at Design/Builder's expense. B. If Owner considers it necessary or advisable that covered Construction be observed by Owner or inspected or tested by others, Design/Builder, at Owner's request, shall uncover, expose or otherwise make available for observation, inspection or testing as Owner may require, that portion of the Construction in question, furnishing all necessary labor, material and equipment. If it is found that such Construction is defective, Design/Builder shall pay all claims costs, losses and damages caused by, arising out of, or resulting from such uncovering, exposure, observation, inspection and testing and of satisfactory replacement or reconstruction, (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals, all court or arbitration or other dispute resolution costs, and all costs of repair or replacement of work of others); and Owner shall be entitled to an appropriate decrease in the Contract Price, and, if the parties are unable to agree as to the amount thereof, Owner may make a Claim therefor as provided in Article 9. If, however, such Construction is not found to be defective, Design/Builder shall be allowed an increase in the Contract Price or an extension of the Contract Times (or Milestones), or both, directly attributable to such uncovering, exposure, observation, inspection, testing, replacement and reconstruction. If the parties are unable to agree as to the amount or extent thereof, Design/Builder may make a Claim therefor as provided in Article 9. EICDC D-900 Standard General Conditions ofthe Contract nehveen Owner and Design/nnildor Copyright ©2002 National Society of Professional Fnginoera fre EJCDC. All rights reserved. Inehtdes City of Pon Collins modifications dated 09/2004 27 12.05 Owner May Stop Construction or Work A. If Construction or Work is defective, or Design/Builder fails to supply sufficient skilled workers or suitable materials or equipment, or fails to furnish or perform Construction or Work in such a way that the completed 6eastfustien Work will conform to the Contract Documents, Owner may order Design/Builder to stop Construction or Work or any portion thereof, until the cause for such order has been eliminated; however, this right of Owner to stop Construction will not give rise to any duty on the part of Owner to exercise this right for the benefit of Design/Builder or any surety or other party. 12.06 Correction or Removal of Defective Construction or Work A. Owner will have authority to disapprove or reject defective Construction or Work and will have authority to require special inspection or testing of the Construction or Work whether or not the Construction or Work is fabricated, installed or completed. If required by Owner, Design/Builder shall promptly, as directed, either correct all defective Construction or Work, whether or not fabricated, installed or completed, or, if the Construction or Work has been rejected by Owner, remove it from the Site and replace it with non - defective Construction or Work. Design/Builder shall bear all direct, indirect, and consequential costs of such correction, replacement and/or removal (including but not limited to all claims, costs, losses and damages caused by, arising out of or resulting from such correction, replacement and/or removal and fees and charges of engineers, architects, attorneys and other professionals and all court, arbitration, or other dispute resolution costs) arising out of or relating to such correction or removal.) 12.07 Correction Period A. If within one year after the date of Substantial Completion of the entire Work or such longer period of time as may be prescribed by Laws or Regulations or by the terms of any applicable special guarantee required by the Contract Documents or by any specific provision of the Contract Documents, any Construction or Work is found to be defective, Design/Builder shall promptly, without cost to Owner and in accordance with Owner's written instructions, (i) correct such defective Construction or Work, or, if it has been rejected by Owner, remove it from the Site and replace it with Construction or Work that is not defective, and (ii) satisfactorily correct or remove and replace any damage to other Construction or Work or the work of others resulting therefrom. If Design/Builder does not promptly comply with the terms of such instructions, or in an emergency where delay would cause serious risk of loss or damage, Owner may have the defective Construction or Work corrected or the rejected Construction or Work removed and replaced, and all cla_ ns costs, losses, and damages caused by, arising out of, or resulting from such removal and replacement (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals, all court or arbitration or other dispute resolution costs, and all costs of repair or replacement of work of others) will be paid by Design/Builder. B. In special circumstances where a particular item of equipment is placed in continuous service before Substantial Completion of all the Work, the correction period for that item may start to run from an earlier date if so provided in the Conceptual Documents. C. Where defective Construction or Work and damage to other Construction or Work resulting therefrom) has been corrected, removed or replaced under this paragraph 12.07, the correction period hereunder with respect to such Construction or Work will be extended for an additional period of one year after such correction or removal and replacement has been satisfactorily completed. 12.08 Acceptance of Defective Construction or Work A. If, instead of requiring correction or removal and replacement of defective Construction or Work, Owner prefers to accept it, Owner may do so. Design/Builder shall pay all costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals and all court or arbitration or other dispute resolution costs) attributable to Owner's evaluation of and determination to accept such defective Construction or Work. If any such acceptance occurs prior to final payment, a Change Order will be issued incorporating the necessary revisions in the Contract Documents, and Owner shall be entitled to an appropriate decrease in the Contract Price reflecting the diminished value of the Construction or Work so accepted. If the parties are unable to agree as to the amount thereof, Owner may make a Claim therefor as provided in Article 9. If the acceptance occurs after final payment, an appropriate amount will be paid by Design/Builder to Owner. 12.09 Owner May Correct Defective Construction or Work A. If Design/Builder fails within a reasonable time after written notice from Owner to correct defective Construction or Work or to remove and replace rejected Construction or Work as required by Owner in accordance with paragraphs 12.06.A or 12.07.A, or if Design/Builder fails to perform the Construction or Work in accordance with the Contract Documents, or if Design/Builder fails to comply with any other provision of the Contract Documents, Owner may, after seven days' written notice to Design/Builder, correct and remedy any such deficiency. B. In exercising the rights and remedies under this paragraph 12.09 Owner shall proceed expeditiously. In connection with such corrective and remedial action, Owner BJCDC D-700 Standard Geveral Conditions of the Contract notwaao Owner end Design/73uilder Copyright 02002 Nalimtal Society of Professional Engineers for EJCDC. All rights reserved. Includes City of Pore Collins modifications dated 09/2004 28 may exclude Design/Builder from all or part of the Site, take possession of all or part of the Construction or Work, and suspend Design/Builders services related thereto, take possession of Design/Builders tools, appliances, construction equipment and machinery at the Site, and incorporate in the Construction or Work all materials and equipment stored at the Site or for which Owner has paid Design/Builder but which are stored elsewhere. Design/Builder shall allow Owner, Owners Consultant, Owners representatives, agents, employees, and other contractors access to the Site to enable Owner to exercise the rights and remedies under this paragraph. C. All claims, costs, losses, and damages (included but not limited to fees and charges of engineers, architects, attorneys and other professionals, all court or arbitration or other dispute resolution costs and all costs of repair or replacement of work of others) incurred or sustained by Owner in exercising such rights and remedies under this paragraph 12.09 will be charged against Design/Builder and a Change Order will be issued incorporating the necessary revisions in the Contract Documents, and Owner shall be entitled to an appropriate decrease in the Contract Price. If the parties are unable to agree as to the amount thereof, Owner may make a Claim therefor as provided in Article 9. D. Design/Builder shall not be allowed an extension of the Contract Times (or Milestones) because of any delay in the performance of the Work attributable to the exercise by Owner of Owner's rights and remedies under this paragraph 12.09. 12.10 No limitation A. Nothing contained in this Article 12 shall be construed to establish a period of limitation with respect to other obligations which the Design/Builder might have under the Contract Documents. Establishment of the time period of one year as described in Section 12.07 relates only to the specific obligation of the Desien/Builder to correct the Work, and has no relationship to the time within which the obligation to comply with the Contract Documents may be sought to be enforced, nor to the time within which proceedings may be commenced to establish the Desilm/Builder's liability with respect to the Design/Builder's obligations other than specifically to correct the Work ARTICLE 13 — PAYMENTS TO DESIGN/BUILDER AND COMPLETION 13.01 Schedule of Values A. The Schedule of Values established as provided in paragraph 2.06.A will serve as the basis for progress payments. Progress payments on account of Unit Price Work will be based on the number of units completed. 13.02 Application for Progress Payment A. On or about the date established in the Agreement for submission of each application for progress payment (but not more often than once a month), Design/Builder shall submit to Owner for review an Application for Payment filled out and signed by Design/Builder covering the Work completed as of the date indicated on the Application and accompanied by supporting documentation as required by the Contract Documents. If payment is requested on the basis of materials and equipment not incorporated in the Work but delivered and suitably stored at the Site or at another location agreed to in writing, the Application for Payment shall also be accompanied by a bill of sale, invoice or other documentation warranting that Owner has received the materials and equipment free and clear of all Liens and evidence that the materials and equipment are covered by appropriate property insurance provided by Design/Builder and other arrangements to protect Owners interest therein, all of which will be satisfactory to Owner. B. Beginning with the second Application for Payment, each Application shall include an affidavit of Design/Builder stating that all previous progress payments received on account of the Work have been applied on account to discharge Design/Builder's legitimate obligations associated with prior Applications for Payment. C. The amount of retainage with respect to progress payments will be as stipulated in the Agreement. D. Any funds that are withheld by Owner shall not be subject to substitution by Design/Builder with securities or any arrangements involving an escrow or custodianship. By executing the Application for Payment form, Design/Builder expressly waives his right to the benefits of Colorado Revised Statutes, Section 24-91-101, et seq. 13.03 Review of Applications for Progress Payments A. Procedure. Progress payments shall be made by the Owner to the Design/Builder according to the following procedure: 1. Owner will, within ten days of receipt of each Application for Payment, either indicate in writing its acceptance of the Application and state that the Application is hemp processed for payment, or return the Application to Design/Builder indicating in writing reasons for refusing to accept the Application. Not more than ten days after accepting such Application the amount will become due and when due will be paid by Owner to Design/Builder. 2. If Owner should fail to pay Design/Builder at the time the payment of any amount becomes due, except EJCDC D-700 Standard General Conditions of dm Contact Betomn Owner and Design/Builder Copyright C2002 National Socioty of Professional Engi,, er. for E]CDC. All fights reserved. Includes City of For; Collins modifications dated 09/2004 29 as provided in paragraph 13.03.13 and as otherwise provided in the Contract Documents. then Design/Builder may, at any time thereafter, upon serving written notice that he will stop the Work within seven days after receipt of the notice by Owner, and after such seven day period, stop the Work until payment of the amount owing has been received. Written notice shall be deemed to have been duly served if sent by certified mail to the last known business address of Owner. 3. Payments due but unpaid shall bear interest at the rate specified in the Agreement 4. No Progress Payment nor any partial or entire use or occupancy of the Project by Owner shall constitute an acceptance of any Work not in accordance with the Contract Documents. B. Reduction in or Refusal to Make Payment. Owner may refuse to make the whole or any part of any such payment, or because of subsequently discovered evidence or the results of subsequent inspections or tests, nullify any previous payment, to the extent that is reasonably necessary to protect Owner from loss because: I. the Construction or Work is defective, or completed Construction or Work has been damaged requiring correction or replacement: or 2. the Contract Price has been reduced by Change Order; or 3. Owner has been required to correct defective Construction or complete Work in accordance with paragraph 12.09.A; or 4. Owner has actual knowledge of the Occurrence of any of the events enumerated in paragraphs 13.03.B.1 through 13.03.B.3 inclusive. or paragraphs 14.02.A.1 through 14.02.A.3 inclusive: or 5. Claims have been made against Owner on account of Design/Builder's performance or furnishing of the Work; or 6. Liens have been filed in connection with the Work except where Design/Builder has delivered a specific Bond satisfactory to Owner to secure the satisfaction and discharge of such Liens: or 7. There are other items entitling Owner to a set off against the amount for which application is made. C. If Owner refuses to make payment of the full amount requested by Design/Builder, Owner must give Design/Builder immediate written notice stating the reasons for such action and promptly pay Design/Builder any amount remaining after deduction of the amount withheld. Owner shall promptly pay Design/Builder the amount withheld or any adjustment thereto agreed to when Design/Builder corrects to Owner's satisfaction the reason for such action. 13.04 Design/Builder's Warranty of Title A. Design/Builder warrants and guarantees that title to all Construction, materials, and equipment covered by any Application for Payment, whether incorporated in the Project or not, will pass to Owner no later than the time of payment free and clear of all Liens. 13.05 Substantial Completion A. When Design/Builder considers the Work ready for its intended use Design/Builder shall notify Owner in writing that the Work is substantially complete (except for items specifically listed by Design/Builder as incomplete) and request that Owner issue a certificate of Substantial Completion. Promptly thereafter, Owner and Design/Builder shall make an inspection of the Work to determine the status of completion. If Owner does not consider the Work substantially complete, Owner will notify Design/Builder in writing giving the reasons therefor. If Owner considers the Work substantially complete, Owner will prepare and deliver to Design/Builder a certificate of Substantial Completion which shall fix the date of Substantial Completion. There shall be attached to the certificate a list of items to be completed or corrected before final payment. At the time of delivery of the certificate of Substantial Completion Owner will deliver to Design/Builder a written determination as to division of responsibilities pending final payment between Owner and Design/Builder with respect to security, operation, safety, protection of Construction, maintenance, heat, utilities, insurance and warranties and guarantees. B. Owner will have the right to exclude Design/Builder from the Site after the date of Substantial Completion, but Owner will allow Design/Builder reasonable access to complete or correct items on the list of items to be completed. 13.06 Partial Utilization A. Prior to Substantial Completion of all the Work, Owner may use or occupy any substantially completed part of the Construction which (i) has specifically been identified in the Contract Documents, or (ii) Owner and Design/Builder agree constitute a separately functioning and usable part of the Construction that can be used by Owner for its intended purpose without significant interference with Design/ Builder's performance of the remainder of the Construction, subject to the following: 1. Owner at any time may request Design/Builder in writing to permit Owner to use or MCDC D-700 Standard General Catdilions ofthe Cnntmcl Between Owner and Desigomailder Copyright 02002 National society of Prnfessicead r tgiacers for EJCDC. All rights reserved. laclndes City of Lon Collins modifications dated 09/2004 30 occupy any such part of the Construction which Owner believes to be ready for its intended use and substantially complete If Design/Builder agrees that such part of the Work is substantially complete Design/Builder will certify to Owner that such part of the Construction is substantially complete and request Owner to issue a certificate of Substantial Completion for that part of the Construction. Design/Builder at any time may notify Owner in writing that Design/Builder considers any such part of the Work ready for its intended use and substantially complete and request Owner to issue a certificate of Substantial Completion for that part of the Work. Within a reasonable time after either such request, Owner and Desien/Builder shall make an inspection of that part of the Work to determine its status of completion If Owner does not consider that part of the Work to be substantially complete Owner will notice Design/Builder in writing giving the reasons therefor. If Owner considers that part of the Work to be substantially complete the provisions of paragraph 13.05 will apply with respect to certification of Substantial Completion of that part of the Work and the division of responsibility in respect thereof and access thereto 2 No use or occupancy of part of the Construction will be accomplished prior to compliance with the requirements of paragraph 510 regarding Property insurance 13.07 Final Inspection A. Upon written notice from Design/Builder that the entire Work or an agreed portion thereof is complete, Owner will make a final inspection with Design/Builder and will notify Design/Builder in writing of all particulars in which this inspection reveals that the Work is incomplete or defective. Design/Builder shall immediately take such measures as are necessary to complete such Work or remedy such deficiencies. 13.08 Final Payment A. Application for Payment. 1. After Design/Builder has completed all such corrections to the satisfaction of Owner and delivered in accordance with the Contract Documents all maintenance and operating instructions, schedules guarantees, Bonds, certificates or other evidence of insurance, certificates of inspection, record documents (as provided in paragraph 6.12) and other documents Design/Builder may make application for final PaYMeDt following the procedure for progress payments 2. The final Application for Payment shall be accompanied (unless previously delivered) by: (j) all documentation called for in the Contract Documents including but not limited to the evidence of insurance required by paragraph 5.04.137: (ii) consent of the surety,if any, to final payment and (iii) complete and legally effective releases or waivers (satisfactory to Owner) of all Liens arising out of or Filed in connection with the Work. 3. In lieu of such releases or waivers of Liens specified in paragraph 13.08.A.2 and as approved by Owner. Design/Builder may furnish receipts or releases in full and an affidavit of Design/Builder that (i) the releases and receipts include all labor, services material and equipment for which a Lien could be filed and (ii) all payrolls, material and equipment bills and other indebtedness connected with the Work for which Owner or Owner's property might in any way be responsible have been paid or otherwise satisfied If any Subcontractor or Supplier fails to furnish such a release or receipt in full, Design/Builder may furnish a Bond or other collateral satisfactory to Owner to indemnifv Owner against any Lien. 4. Releases or waivers of liens and the consent of the surety to finalize payment are to be submitted on forms conforming to the format of the Owner's standard forms bound in the Project manual B. Final Payment and decelrtance. If Owner is satisfied that the Work has been completed and Design/Builders other obligations under the Contract Documents have been fulfilled, Owner will, within ten days after receipt of the final Application for Payment, give written notice to Design/Builder that the Work is acceptable. Otherwise, Owner will return the Application to Design/Builder, indicating in writing the reasons for refusing to process final payment, in which case Design/Builder shall make the necessary corrections and resubmit the Application. C. Payment Becomes Due. Thirty days after the presentation to Owner of the acceptable Application and accompanying documentation, in appropriate form and substance and with Owner's notice of acceptability, the amount will become due and will be paid by Owner to Design/Builder, subject to paragraph 16.05.A.1 and 16.05 A 2 of these General Conditions. 13.09 Final Completion Delayed A. If, through no fault of Design/Builder, final completion of the Work is significantly delayed, Owner shall, upon receipt of Design/Builder's final Application for Payment, and without terminating the Agreement, make payment of the balance due for that portion of the Work fully completed and accepted. if the remaining balance to be held by Owner for Work not fully completed or corrected is less than the retainage stipulated in the Agreement, and if Bonds have been furnished as required in paragraph 5.0LA, the written consent of the surety to the payment of the balance due for that portion of the Work fully completed and accepted EJCDC D-700 Standard Gooeral Conditions ofthe Cool= Between Omner and Design/Builder Copyright 02002 National Society of Professional Engineers for EJCDC. All rights,"med. Includes City of fool C. lmn onodifiealioos dated 09/2004 31 shall be submitted by Design/Builder to Owner with the Application for such payment. Such payment shall be made under the terms and conditions governing final payment, except that it shall not constitute a waiver of Claims. 13.10 Waiver of Claims A. The making and acceptance of final payment will constitute: I. A waiver of all Claims by Owner against Design/Builder. except Claims arising from unsettled Liens, from defective Construction appearing after final inspection Pursuant to paragraph 13 07 from failure to comply with the Contract Documents or the terms of anv special guarantees specified therein or from Design/Builder's continuing obligations under the Contract Documents; and 2. A waiver of all Claims by Design/Builder against Owner other than those previously made in writing and still unsettled. ARTICLE 14 — SUSPENSION OF WORK AND TERMINATION 14.01 Owner May Suspend Work A. At any time and without cause, Owner may suspend the Work or any portion thereof for a period of not more than 90 days by notice in writing to Design/Builder which will fix the date on which Work will be resumed. Design/Builder shall resume the Work on the date so fixed. Design/Builder shall be allowed an adjustment in the Contract Price or an extension of the Contract Times, or both, directly attributable to any such suspension if Design/Builder makes a Claim therefor as provided in Article 9. 14.02 Owner May Terminate for Cause A. Upon Tthe occurrence of any one or more of the following events justifies ,,,,,,,,,,,,,ion o�,o Owner may terminate this Agreement as provided herein: I Design/Builder's persistent failure to perform the Work in accordance with the Contract Documents (including, but not limited to, failure to supply sufficient skilled workers or suitable materials or equipment or failure to adhere to the progress schedule established under paragraph 2.06 A as adjusted from time to time Pursuant to paragraph 6.05). 2. Design/Builders disregard of Laws or Regulations of any public body having jurisdiction 3. Design/Builder's violation in any substantial way of Provisions of the Contract Documents B. If one or more of the events identified in paragraph 14.02.A occur, Owner may, after giving Design/Builder (and the surety, if any) seven days' written notice, terminate the services of Design/Builder, take possession of any completed Drawings and Specifications prepared by or for Design/Builder (subject to the indemnification provisions of paragraph 3.05.A), exclude Design/Builder from the Site, and take possession of the Work and of all Design/Builder's tools, appliances, construction equipment and machinery at the Site and use the same to the full extent they could be used by Design/Builder (without liability to Design/Builder for trespass or conversion), incorporate in the Work all materials and equipment stored at the Site or for which Owner has paid Design/Builder but which are stored elsewhere, and finish the Work as Owner may deem expedient. In such case Design/Builder shall not be entitled to receive any further payment until the Work is finished. If the unpaid balance of the Contract Price exceeds all claims costs, losses and damages sustained by Owner arising out of or resulting from completing the Work (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals and all court or arbitration or other dispute resolution costs) such excess will be paid to Design/Builder. If such claims, costs, losses and damages exceed such unpaid balance, Design/Builder shall pay the difference to Owner. Such claims, costs, losses and damages incurred by Owner will be incorporated in a Change Order. When exercising any rights or remedies under this paragraph Owner shall not be required to obtain the lowest price for the Work performed. C. Notwithstanding paragraph 14.02.13, Design/ Builder's services will not be terminated if Design/Builder begins, within seven days of receipt of notice of intent to terminate, to correct its failure to perform and proceeds diligently to cure such failure within no more than 30 days of receipt of said notice. D. Where Design/Builder's services have been so terminated by Owner, the termination will not affect any rights or remedies of Owner against Design/Builder then existing or which may thereafter accrue. Any retention or payment of moneys due Design/Builder by Owner will not release Design/Builder from liability. 14.03 Owner May Terminate for Convenience A. Upon seven days' written notice to Design/Builder, Owner may, without cause and without prejudice to any other right or remedy of Owner, elect to terminate the Contract. In such case, Design/Builder shall be paid (without duplication of any items) for: FJCDC D�700 Standard General Conditions ofthe Contnon Between Owner and Design/Boilder Copyright 02002 National Society of Professional Engineers for MCDC. All rights reserved. Includes Cify of Fort Collins modifications datod 09/2004 32 I. Completed and acceptable Work executed in accordance with the Contract Documents prior to the effective date of termination including fair and reasonable suns for overhead and profit on such Work: 2 Expenses sustained prior to the effective date of termination in performing services and furnishing labor, materials or equipment as required by the Contract Documents in connection with uncompleted Work plus fair and reasonable sums for overhead and profit on such expenses: and 3. Amounts paid in settlement of terminated contracts with Subcontractors Suppliers and others (including but not limited to all fees and charges of engineers, architects, attorneys and other professionals and all court or arbitration or other dispute resolution costs incurred in connection with termination of contracts with Subcontractors Suppliers and others)? and 4 Reasonable expenses directly attributable to termination. B. Except as provided in paragraph 14.03.C, Design/Builder shall not be paid on account of loss of anticipated profits or revenue or other economic loss arising out of or resulting from such termination. 14.04 Design/Builder May Stop Work or Terminate A. If, through no act or fault of Design/Builder, the Work is suspended for a period of more than 90 days by Owner or under an order of court or other public authority, or Owner fails to act on any Application for Payment within thirty days after it is submitted or Owner fails for thirty days to pay Design/Builder any sum finally determined to be due, then Design/Builder may, upon seven days' written notice to Owner, and provided Owner does not remedy such suspension or failure within that time, terminate the Agreement and recover from Owner payment on the same terms as provided in paragraph 14.03.A. In lieu of terminating the Agreement and without prejudice to any other right or remedy, if Owner has failed for 30 days to pay Design/Builder any sum finally determined to be due, Design/Builder may upon seven days' written notice to Owner stop the Work until payment is made of all such amounts due Design/Builder, including interest thereon. The provisions of this paragraph 14.04.A are not intended to preclude Design/Builder from making Claim under Article 9 for an increase in Contract Price or Contract Times or otherwise for expenses or damage directly attributable to Design/Builder's stopping Work as permitted by this paragraph. ARTICLE 15 — DISPUTE RESOLUTION 15.01 Methods and Procedures A. Dispute resolution methods and procedures, if any, shall be as set forth in the Supplementary Conditions. If no such method and procedure has been set forth, Owner and Design/Builder may exercise such rights or remedies as either may otherwise have under the Contract Documents or by Laws or Regulations in respect of any dispute. ARTICLE 16—MISCELLANEOUS 16.01 Giving Notice A. Whenever any provision of the Contract Documents requires the giving of written notice, it will be deemed to have been validly given if delivered in person to the individual or to a member of the firm or to an officer of the corporation for whom it is intended, or if delivered at or sent by certified mail, postage prepaid, to the last business address known to the giver of the notice. 16.02 Computation of Times A. When any period of time is referred to in the Contract Documents by days, it will be computed to exclude the first and include the last day of such period. If the last day of any such period falls on a Saturday or Sunday or on a day made a legal holiday by the law of the applicable jurisdiction, such day will be omitted from the computation. 16.03 Cumulative Remedies A. The duties and obligations imposed by these General Conditions and the rights and remedies available hereunder to the parties hereto are in addition to, and are not to be construed in any way as a limitation of, any rights and remedies available to any or all of them which are otherwise imposed or available by: 1. Laws or Regulations: or 2. any special warranty or guarantee; or 3, other Provisions of the Contract Documents B. The provisions of paragraph 16.03.A will be as effective as if repeated specifically in the Contract Documents in connection with each particular duty, obligation, right and remedy to which they apply. EJCDC D-700 Swodw ri Gencrol Conditions of the ContmCt Between Owner and DesigoBullder Copyright (02002 National Society of Professional Engineers for L/CDC. All tights reserved. Includes City effort Collins modifications dined 09/2004 33 16.04 Survival of Obligations A. All representations, indemnifications, warranties and guarantees made in, required by or given in accordance with the Contract Documents, as well as all continuing obligations indicated in the Contract Documents, will survive final payment, completion and acceptance of the Work and termination or completion of the Contract. 16.05 Controlling Law &f he n_e The laws of the State of Colorado shall apply to this Agreement, including but not limited to the following pertinent Colorado statutes: 1. Colorado Revised Statutes (CRS 8-17-101) requires that Colorado labor be employed to perform the work to the extent of not less than 80 percent (80%) of each type or class of labor in the several classifications of skilled and common labor employed on the project. Colorado labor means any person who is a bona fide resident of the State of Colorado at the time of employment, without discrimination as to race, color, creed, age, religion or sex. 2. If a claim is filed, Owner is required by law (CRS 38-26-107) to withhold from all payments to Design/Builder sufficient funds to insure the payment of all claims for labor, materials, team hire, sustenance, provisions, provender, or other supplies used or consumed by Design/Builder or his Subcontractors in or about the performance of the work. Such funds must be withheld until said claims have been paid or such claims as filed have been withdrawn, such payment or withdrawn to be evidenced by filing with Owner a receipt in full or an order for withdrawal in writing and signed by the person filing such a claim or his duly authorized agents or assigns. Such funds shall not be withheld longer than ninety (90) days following the date fixed for final settlement, as published in a public newspaper in accordance with the law, unless an action is commenced within that time to enforce such unpaid claim and a notice of lis pendens is filled with the Owner. At the expiration of such ninety (90) day period, Owner shall pay to Design/Builder such moneys and funds as are not the subject of suit and lis pendens notices, and shall retain only sufficient funds to insure the payment of judgments which may result from the suit. EJCDC D-700 Sla,tdard Goneml Conditions of the Contract nebvcmt Owner and Deaign/Buildec Copyright 02002 National Society ofProfessional Gigincers for WCDC. All tights reserved. Includes City of Poet Collins modifications dated 09/2004 34 OWNER: CITY OF FA RT COL INS DESIGN/BUILDER: By: Johnson Controls, Inc. D11fn�Atteberry, City Manager By: c. ? l� By: ames . O'Neill II, CPPO, FNIGP Name Bruno A. B asii otter fecl r of Purchasing and Risk Management c, Date: Foram 'cn SEAbT'rE T: Clerk Address for giving notices: PO Box 580 Designated Representative: Name Title: Address: Phone: Facsimile Address for giving notices: 10289 W. Centennial Rd. Littleton, CO 80127 License No. (If DESIGN/BUILDER is a corporation, attach evidence of authority to sign.) Designated Representative: Title: Address: Phone: Facsimile: 7 SECTION 00800 SUPPLEMENTARY CONDITIONS SC-5 Bonds and Insurance ADD the following language in Section 5.03 Paragraph A.1 Certificates oflnsurance Additional Insureds: City ofFort Collins 7/96 Section 00800 Page 1 Attachment #1 - City-wide Lighting Scope vroup vne name Area uescnpnon Flits Exist Pixts Proposed Retrofit Description Sensor Typ Facilities 117 North Mason Open Office 10 10 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Sind, 2x4 Ref Facilities 117 North Mason Open Office 2 0 No Retrofit at this time Facilities 117 Noah Mason Open Office 2 2 Retrofit fixture wl (2) F32T81ADV841/EW/LUALT0 28W Iamps & 2L I0P-LP Facilities 117 North Mason Open Office 2 2 Retrofit fixture wl (2) F17TWLe41/ALTO Lamps, 21 IOP-Stnd Bllst, & 2x2 kit Facilities 117 North Mason Open Office 2 0 Sensor Spec CDT1500 Facilities 117 North Mason Break Hall 2 2 Retrofit fixture w/ (2) F17T8,71-84VALTO Lamps, 2L IOP-Stnd BIIst, & 2x2 kit Facilities 117 North Mason Break Room 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Facilities 117 North Mason Copy Room 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 117 North Mason Private Office 2 2 Retrofit fixture w/ (2) F1 B71-841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities 117 Noah Mason Private Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Ref Facilities 117 North Mason Open Once 4 4 Retrofit fixture w/ (3) F32TB/ADV8,H/EW/LUALTO 28W lamps & 3L IOP LP Facilities 117 North Mason Open Office 3 3 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALT0 28W Iamps & 2L IOP-LP Facilities 117 North Mason Open Office 1 0 Sensor Spec 1CDT,1CUS Facilities 117 North Mason Supply Room 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W Iamps, 2L IOP Stud, & 2x4 Raft Facilities 117 North Mason Supply Room 1 0 Sensor Spec WSIR Facilities 117 North Mason Fac. Service File Rm 3 3 Retrofit fixture wl (2) F32T8/ADV841/EW/LL/ALTO 28W [amps. 2L IOP-Stud, & 8' Socket Plat Facilities 117 North Mason Fac. Service File Rm 2 2 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stud, & 8' Socket Plat Facilities 117 North Mason Fac. Service File Rm 4 4 Retrofit fixture w/ (2) F32T8/ADV84t/EW&UALTO 28W lamps & 2L IOP-LP Facilities 117 North Mason Fac. Service File Rm 2 0 Sensor Spec TIMER Facilities 117 North Mason Fac. Service File Rm 4 4 Retrofit fixture w/ (2) F32T8/AOV841/EW/LUALTO 28W lamps, 2L IOP-Smd, & 8' Socket Plat Facilities 117 North Mason Fac. Service File Rm 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 117 North Mason Fac. Service Lower File 1 1 Retrofit fixture w/ (2) F32TS/ADV841/EW/LL/ALTO 28W lamps, 2L IOP-Sind, & 8' Socket Plat Facilities 117 North Mason Fac. Service Lower File 3 3 Install new 4' 2L28T8 Strip - IOP-Stnd (wireguard & Photocell) Facilities 117 Noah Mason Fac. Service Lower File 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 21 IOP-LP (Photocelp Facilities 117 North Mason File Corridor 4 4 Retrofit fixture w/ (4) F32TWADV8411EW/LUALT0 28W lamps, 4L IOP LP Facilities 117 North Mason Large Conference Room 12 12 Retrofit fixture w/ 13) F32T8/ADV8411EW/LUALT0 28W lamps, IL IOP LP, & 2L IOP LP (Dua Facilities 117 North Mason Large Conference Room 1 0 Sensor Spec CDT1000 Facilities 117 Noah Mason Open Office 12 12 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities 117 Noah Mason Open Office 2 2 Retrofit fixture wl (2) F17T8/TL841/ALTO Lamps. 21 IOP-Sind Bllst, & 2x2 Kit Facilities 117 Noah Mason Storage Room 1 1 Retroflfxture w/ (2) F32T8/ADV841/EW/LUALTO 28W[amps. 2L IOP Sind, 2x4 Refl Facilities 117 North Mason RR 1 i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 117 North Mason RR t i install new 2'Vanity Fixture w/ (2) F17T8/iL84VEC0 lamps -QHE LP BIIst Facilities 117 North Mason RR 1 0 No Retrofit at this time Facilities 117 North Mason RR 1 0 Sensor Spec WSIR Facilities 117 North Mason Supply Room 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 OF Sind, 2x4 Red Facilities 117 North Mason Supply Room 1 0 Sensor Spec WSIR Facilities 117 North Mason Corridor 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilites 117 Noah Mason Condor 1 1 Retrofit fixture w/ (2) F32T8/ADV84t/EW/LUALTO 28W lamps & 21 IOP-LP Facilities 117 North Mason Corridor 3 3 Install new 8' 2L28T8 Wrap-2L IOP-Sind Bllst Facilities 117 North Mason Corridor 1 1 Install new 8' 2L28T8 Wrap-2L IOP-Smd Sllst Facilities 117 North Mason Womens RR 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L IOP-LP Facilities 117 Noah Mason Warrens RR 1 1 Install new 2' Vanity Fixture W (2) P17T8/TL84t/ECO lamps -QHE LP Biist Facilities 117 Noah Mason Warrens RR 1 0 Sensor Spec WSIR Facilities 117 North Mason Mens RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Re0 Facilities 117 North Mason Mens RR 1 i Install new 2'Vanity Fixture w/ (2) F17TB7L841/ECO Iamps- ORE LP BIIst Facilities 117 North Mason Mans RR 1 0 Sensor Spec WSIR Facilities 117 North Mason IT Room 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 11, & 2L IOP LP Attachment #1 - City-wide Lighting Scope --, —1i,1—Ine .,a �escnpuon nxcs Exist Foas Proposed Retrofit Description Sensor T Facilities 117 North Mason IT Room 1 0 Sensor Spec WSIR-2P Facilities 117 North Mason Janitor 1 0 No Retrofit at this time Facilities 117 North Mason Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps. 1L & 2L IOP LP Facilities 117 North Mason Office 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I & 2L IOP LP Facilities 117 North Mason Off. 1 0 Sensor Spec WSIR-2P Facilities 117 North Mason Storage Warehouse 4 4 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28Wlamps, 4L IOP-Sind, & 8' Facilities 117 North Mason Storage Warehouse i 1 (112) Socke Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP-Stnd, & e' Socket Plat Facilities 117 North Mason Storage Warehouse 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. (112) 4L IOP-Sind, & 8' Socke Facilities 117 North Mason Storage Warehouse 3 3 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALT0 28W lamps, (1/3) 3L IOP-Sind & 4' Center Facilities 117 North Mason Cages 3 3 Install new 4' 2128T8 Strip- IOP-Sind (Photocell) Facilities 117 North Mason Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stud, & 8' Socket Plat Facilities 117 North Mason RR 1 0 No Retrofit at this time Facilities 117 North Mason RR 1 i Install new 2'Vanity Fixture w/(2)F17T8/I'LS41/ECO lamps -OHE LP BIIst Facilities 117 North Mason RR 1 0 Sensor Spec WSIR Facilities 117 North Mason Receiving 4 4 Retrofit fixture w/ (2) F32T&ADV841/EWTUALTO 28W lamps, 2L IOP-Stnd, & 8' Socket Plat Facilities 117 North Mason Receiving 1 0 No Retrofit at this time Facilities 117 Noah Mason Receiving Corridor 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, (1/2) 4L IOP-Sind, & 8' Socke Facilities 117 Noah Mason Receiving Corridor 1 1 Retrofit fixture w/ (2) F32T8/AOV841/EW/LUALTO 28W lamps. 2L IOP-Shad. & 8' Socket Plat Facilities 117 North Mason Wood Shop 8 8 Retrofit fixture w/ (4) F32T8/ADV8411EW/LUALT0 28W lamps, 4L IOP-LP, & 8' Socket Plate Facilities 117 North Mason Wood Shop 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 117 Noah Mason Tool Storage 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALT0 28W lamps, 2L IOP-Stnd, & 8' Socket Plat Facilities 117 North Mason Private Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps. I & 2L IOP LP Facilities 117 Noah Mason Private Office 1 i Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L & 2L IOP LP Facilities 117 North Mason Private Office 2 2 Retrofit fixture w/ (3) F32T8/AOV841/EW/LUALT0 28W lamps, I & 2L IOP LP Facilities 117 North Mason Private Office 1 0 Sensor Spec WSIR-2P Facilities 117 North Mason Conference 3 3 Retrofit fixture wl (3) F32T8/ADV841/EW/LUALT0 28W lamps & 3L IOP LP Facilities 117 North Mason Conference 4 4 Retrofit fixture w/ (2) F17T87TL841/ALTO Lamps, 2L IOP-Sind BIIs6 & 2x2 kit Facilities 117 North Mason Plan Room 4 4 Retrofit fixture w/ (2) F17Te,71-e41/ALTO Lamps. 2L IOP-Sind BIIs6 & 2x2 kit Facilities 117 North Mason Plan Roam 4 4 Retrofit fixture w/(3)F32T8/AOV84VEWTUALTO 28Wlamps&3L IOP LP Facilities 117 North Mason Plan Room 1 0 Sensor Spec CUS1000 Facilities 117 Noah Mason Open Once 10 10 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP Stnd. 2x4 Re0 Facilities 117 North Mason Open Office 3 3 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities 117 Noah Mason Corridor 1 1 Retrofilfixlure w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 117 North Mason Office- Vacant 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L & 2L IOP LP Facilities 117 Noah Mason Office - Vacant 1 0 Sensor Spec WSIR-21' Facilities 117 North Mason Office 2 2 Retrofit fixture w/(3)F32T8/ADV84VEWTLJALTO 28Wlamps. lL&2L IOP LP Facilities 117 North Mason Office i 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W Iamps & 2L IOP-LP Facilities 117 North Mason Once 2 2 Retrofit fixture w/ (2) P17T8,71841/ALTO Lamps, 2L IOP-Sind BIIs6 & 2x2 kit Facilities 117 North Mason Office 1 0 Sensor Spec WSDT-2P Facilities 117 North Mason Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W Iamps, IL IOP LP, & 2L IOP LP Facilities 117 North Mason Office 1 0 (Due Sensor Spec CIR Facilities 117 North Mason Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/WALT0 28W lamps, 2L IOP Stud, 2x4 Refl Facilities 117 North Mason Office 2 2 Retrofit fixture w/ (2) F17T8,71841/ALTO Lamps, 2L IOP-Sind BIIs6 & 2x2 kit Facilities 117 Noah Mason Office 1 0 Sensor Spec CUR Facilities 117 North Mason Exterior 11 0 No Retrofit at this time Facilities 117 North Mason Exterior 4 0 No Retrofit at this time Facilities 117 Noah Mason Exterior 3 0 No Retrofit at this time Attachment #1 - City-wide Lighting Scope Facilities 117 North Mason Exterior 1 0 No Retrofit at this time - Facilities 117 North Mason Vending 1 0 Sensor Spec VEND MISER - Facilities 200 West Mountain Entry Hall 10 10 Retrofit fixture w/ (2) F32T8/ADV84llEW/LUALTO 28W lamps & 2L IOP-LP Facilities 200 West Mountain Entry Hall 2 2 Install new Green LED Exit w/ Battery Back up Facilities 200 West Mountain Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L [OR Sind. & 2x4 Refl Facilities 200 West Mountain Open Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L OF Stud, & 2x4 Reg Facilities 200 West Mountain Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind. & 2x4 Rea Facilities 200 West Mountain Conference 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OR Sind, & 2x4 Rea Facilities 200 West Mountain Corridor 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stud, & 2x4 Rea Facilities 200 West Mountain Conference 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L OF Sind, & 2x4 Reif Facilities 200 West Mountain Womens RR 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 200 West Mountain Womens RR 1 0 No Retrofit at this time Facilities 200 West Mountain Mans RR 1 0 No Retrofit at this time Facilities 200 West Mountain Mans RR 3 3 Retrofit fixture wl (2) F32T8/ADV841/EW/LL/ALTO 28W Iamps & 2L IOP-LP facilities 200 West Mountain Open Office -Triad 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, & 2x4 Reg Facilities 200 West Mountain Open Once -Triad 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, & 2x4 Rea Facilities 200 West Mountain Open Office -Triatl 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW1LUALTO 28W lamps, 2L ]OR Sintl, & 2x4 Rea Facilities 200 West Mountain Open Office - Triad 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/I-UALTO 28W Iamps, 2L IOP Stud, & 2x4 Rea Facilities 200 West Mountain Open Office - Triad 1 1 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALTO 28W lamps, 2L IOP Sind, & 2.4 Refl Facilities 200 West Mountain Open Office- Triad 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Sind, & 2x4 Reg Facilities 200 West Mountain Private Office 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities 200 West Mountain Private Office 1 0 Sensor Spec WSIR Facilities 200 West Mountain HC RR 1 0 No Retrofit at this time Facilities 200 West Mountain HC RR 1 0 No Retrofit at this time Facilities 200 West Mountain HC RR 1 0 Sensor Spec WSIR Facilities 200 West Mountain Mach / Cust 1 1 Replace Lamp w/ 23W Screw in CF Facilities 200 West Mountain Triad Engineering 12 12 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sind, & 2x4 Reg Facilities 200 West Mountain Triad Engineering 4 4 Retrofit fixture w/ (2) P17T8/TL841/ALTO Lamps, 2L IOP-Stud BIIst, & 2x2 kit Facilities 200 West Mountain Storage Room 1 1 Replace Lamp w/ 23W Screw in CIF Facilities 200 West Mountain Triad Engineering 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21, IOP Stnd, & 2x4 Reg Facilities 200 West Mountain Triad Engineering Storagc 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Star, & 2x4 Reg Facilities 200 West Mountain Triad Engineering Shop 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Rea Facilities 200 West Mountain Privacy Network 7 7 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OR LP, delamped Facilities 200 West Mountain Privacy Network 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/I.UALTO 28W lamps, (0.5) 4L IOP LP Facilities 200 West Mountain Privacy Network 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, (0.5) 4L IOP LP Facilities 200 West Mountain Privacy Network 13 13 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L [OR LP, delamped Facilities 200 West Mountain Privacy Network 1 1 Install new Green LED Exit w/ Battery Back up Facilities 200 West Mountain Privacy Network 1 1 Retrofit fixture w/ (2) F17TB TL841/ALTO Lamps, 2L IOP-LP Bilst, & 2x2 kit Facilities 200 West Mountain Privacy Network 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, (0.5) 4L IOP LP Facilities 200 West Mountain Privacy Network 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OR Sind, & 2x4 Rea Facilities 200 West Mountain Copy Room 1 i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L OF End, & 2x4 Rep Facilities 200 West Mountain Network Room 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EWILUALTO 28W lamps. (112) 4L IOP Sind. & 2x4 Reg Facilities 200 West Mountain Open Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L [OR LP, delamped Facilities 200 West Mountain Open Office 1 0 No Retrofit at this time Facilities 200 West Mountain Office 2 2 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Reg Facilities 200 West Mountain Natural Resources 16 16 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L IOP LP Facilities 200 West Mountain Natural Resources 2 0 No Retrofit at this time (Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Forte Exist Fills Proposed Retrofit Description Sensor Type Sensor Oty Facilities 200 West Mountain Natural Resources 12 12 Retroftfixture w/ (1) F32T8/ADV841/EW/LL/ALTO 28W lamps & (1/4) 4L IOP-LP Facilities 200 West Mountain Natural Resources 4 4 Retrofitfixlure w/ (1) F32T8/ADV84 /EW/LL/ALTO 28W lamps & (1/2) 2L IOP-LP Facilities 200 West Mountain Natural Resources t 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, & 2x4 Reg Facilities 200 West Mountain Private Office 4 4 Retrofit fixture w/ 12) F32T8/ADV841/EW/LUALTO 28W lamps, (112) 4L NOR Sind, & 2x4 Bell Facilities 200 West Mountain Private Office 1 0 Sensor Spec CIR i Facilities 200 West Mountain Private Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Reg Facilities 200 West Mountain Private Office 1 0 Sensor Spec WSOT 1 Facilities 200 West Mountain Private Office 2 2 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Red Facilities 200 West Mountain Private Office 1 0 Sensor -Spec WSDT 1 Facilities 200 West Mountain Private Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Reg Facilities 200 West Mountain Private Office 3 3 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps & (1/3) 3L IOP-LP Facilities 200 West Mountain Private Office 1 0 Sensor Spec WSIR-2P i Facilities 200 West Mountain Private Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21, IOP Sind, & 2x4 Refi Facilities 200 West Mountain Private Office 3 3 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & (113) 3L IOP-LP Facilities 200 West Mountain Private Office 1 0 Sensor Spec WSIR-2P 1 Facilities 200 West Mountain Private Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L [OR Sind, & 2x4 Bell Facilities 200 West Mountain Private Once 3 3 Retrofit fixture w/ (1) F3218/ADV841/EW/LUALTO 28W lamps & (1/3) 3L IOP-LP Facilities 200 West Mountain Private Office 1 0 Sensor Spec WSIR-2P i Facilities 200 West Mountain Private Once 2 2 Retrofit fixture w/ (2) F3218/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, delamped Facilities 200 West Mountain Private Once 3 3 Retrofit fixture wl (1) F32T8/ADV841/EW/LUALTO 28W lamps & (1/3) 3L IOP-LP Facilities 200 West Mountain Private Office 1 0 Sensor Spec WSIR-2P 1 Facilities 200 West Mountain Corridor 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, delamped Facilities 200 West Mountain Corridor 1 0 No Retrofit at this time Facilities 200 West Mountain Open Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L [OR Sind, & 2x4 Reg Facilities 200 West Mountain Open Office 2 2 Retrofit fixture w/(1)F32TWADV841/EW/LUALTO 28W lamps & (1/2) 2L IOP-LP Facilities 200 West Mountain Open Office 1 1 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & 1L IOP-LP Facilities 200 West Mountain Open Office 1 0 Sensor Spec CUS2000-1R t Facilities 200 West Mountain Private Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OR Sind, & 2x4 Reg Facilities 200 West Mountain Private Office i i Retrofitfixture w/ (1) F32T8/ADV84t/EW/LL/ALT0 28W lamps & (1/3) 3L IOP-LP Facilities 200 West Mountain Private Once t i Retrofit fixture w/ (1) F25TBu7L841/ALTO & (1/3) 3L IOP-LP Facilities 200 West Mountain Private Office 1 1 Retrofit fixture w/ (1) F17T8lrLe41/ALTO & (1/3) 3L IOP-LP Facilities 200 West Mountain Private Office 1 1 Retrofit fixture w/(2)F32T8/AOV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities 200 West Mountain Private Office 1 0 Sensor Spec WSIR-2P i Facilities 200 West Mountain Private Office 4 4 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Reg Facilities 200 West Mountain Private Office 2 2 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & (113) 3L IOP-LP Facilities 200 West Mountain Private Office i t Retrofit fixture w/ (1) F17TSfrL841/ALTO & (1/3) 31 IOP-LP Facilities 200 West Mountain Private Office t 0 Sensor Spec WSIR 1 Facilities 200 West Mountain Mena RR 1 1 Install new4' 2L28T8 Wrap Fixture- IOP Sind Facilities 200 West Mountain Mans RR 1 1 Install New 13W CF Drum Fixture Facilities 200 West Mountain Warrens RR 1 1 Install new 4' 2L28T8 Wrap Fixture- ]OR Sind Facilities 200 West Mountain Womens RR 1 1 Install New 13W CF Drum Fixture Facilities 200 West Mountain Warrens RR 1 0 No Retrofit at this time Facilities 200 West Mountain Womens RR t 0 Sensor Spec WSIR t Facilities 200 West Mountain Break Room t i Retrofit fixture w/ (2) F32T8/ADV841/EW/1-UALT0 28W lamps & 2L IOP-LP Facilities 200 West Mountain Storage Room 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Facilities 200 West Mountain Custodian 1 1 Replace Lamp w/ 18W Screw in CF Facilities 200 West Mountain Corridor 2 2 Retrofit fixture wl (2) F32T8/ADV841/EW/1-UALTO 28W lamps & 2L IOP-LP Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist FortsProposed Retrofit Description Sensor Type Sensor Qty Facilities 200 West Mountain Corridor 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Facilities 200 West Mountain Condor 1 0 No Retrofit at this time Facilities 200 West Mountain Corridor 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Said. & 2x4 Rem Facilities 200 West Mountain C.hF RR Mens 1 1 Install New 2L 13W CF Drum Fixture Facilities 200 West Mountain Genf RR Men. 1 0 No Retrofit at this time Facilities 200 West Mountain Con' RR Mans 1 0 Sensor Spec WSIR 1 Facilities 200 West Mountain Conf RR Womens i i Install New 2L 13W CF Drum Fixture Facilities 200 West Mountain Cent RR Womens 1 0 No Retrofit at this time Facilities 200 West Mountain Cent RR Womens 1 0 Sensor Spec WSIR i Facilities 200 West Mountain Training Room 12 12 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Su d, & 2x4 Reg Facilities 200 West Mountain Corridor 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 200 West Mountain Corridor 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Facilities 200 West Mountain Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stop, & 2x4 Reg Facilities 200 West Mountain Office 1 0 Sensor Spec WSIR 1 Facilities 200 West Mountain Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sum. & 2x4 Rem Facilities 200 West Mountain Office 1 0 Sensor Spec WSIR i Facilities 200 West Mountain Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind. & 2x4 Rem Facilities 200 West Mountain Office 1 0 Sensor Spec WSUS i Facilities 200 West Mountain Open Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps. 2L ]OR Sam, & 2x4 Reg Facilities 200 West Mountain Open Office 1 0 Sensor Spec CIR t Facilities 200 West Mountain Corridor 1 i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 200 West Mountain Exterior 2 0 No Retrofit at this time Facilities 200 West Mountain Exterior 18 18 Install new 1L 13W CF Square Fixture Facilities 200 West Mountain Exterior 2 0 No Retrofit at this time Facilities 200 West Mountain Exterior 1 0 No Retrofit at this time Facilities 200 West Mountain Exterior 4 0 No Retrofit at this time Facilities 200 West Mountain Exterior 3 0 No Retrofit at this time Facilities 281 N. College Lobby 4 0 No Retrofit at this time Facilities 281 N. College Lobby 11 0 No Retrofit at this time Facilities 281 N. College Lobby 5 5 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28WIamps, 4L 1OR LP, delamped Facilities 281 N. College Lobby 11 11 Install new 100W CMH Can (High Height) Facilities 281 N. College Lobby 3 3 Install New 42W CF Can Facilities 281 N. College Lobby 3 3 Install new Green LED Exit w/ Battery Back up Facilities 281 N. College Lobby 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, (1/2) 4L IOP-LP, & 2L Intlusln Facilities 281 N. College Lobby 4 4 Retrofitfixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, (1/2) 4L IOP-LP, 8' 2L Intlusln Facilities 281 N. College Lobby 2 2 Retrofilfixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-LP, V 2L Industrial He Facilities 281 N. College Lobby 16 16 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & (114) 4L IOP-LP Facilities 281 N. College Lobby 4 4 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & (112) 2L IOP-LP (Very Difficr Facilities 281 N. College Lobby 2 2 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & 1L IOP-LP (Very Difficult Ins Facilities 281 N. College Entry 1 0 No Retrofit at this time Facilities 281 N. College Office 3 3 Retrofit fixture w/ (2) F17TS71-841/ALTO Lamps, 2L IOP-Stnd Bllst, & 2x2 kit Facilities 281 N. College Office 2 2 Replace lamp w/ 13W Screw in CF Facilities 281 N. College Office 4 4 Retrofit fixture w/ (2) F17T8/T1-841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 4 4 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Slnd Bllst, & 2x2 kit Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 6 6 Retrofit fixture w/ (2) F17T8(TL841/ALTO Lamps, 2L IOP-Sand Bgst. & 2x2 kit Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fixts Proposed Retrofit Description Sensor Type Sensor City Facilities 281 N. College Once 1 0 Sensor Spec CIR i Facilities 281 N. College Conference 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Facilities 281 N. College Conference 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Conference 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities 281 N. College Conference 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities 281 N. College Conference 3 0 No Retrofit at this time Facilities 281 N. College Conference 1 0 Sensor Spec OR i Facilities 281 N. College Conference 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Conference 2 2 Retrofit fixture W/(2)F32T8/ADV841/EW/LUALTO 28WIamps & (1/2) 4L IOP-LP Facilities 281 N. College Conference 5 0 No Retrofit at this time Facilities 281 N. College Conference 1 1 Retrofit w/ 18W OF Downlighl Kit (6" & Dimmable) Facilities 281 N. College Conference 1 0 Sensor Spec CIR-1R 1 Facilities 281 N. College Elevator Mechanical 1 1 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Facilities 281 N. College Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 11 & 2L IOP LP Facilities 281 N. College Once 1 0 Sensor Spec WSIR-2P 1 Facilities 281 N. College Open Office 11 0 No Retrofit at this time Facilities 281 N. College Open Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Slnd, 2x4 Re8 Facilities 281 N. College Open Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities 281 N. College Open Once 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 21 IOP-LP Facilities 281 N. College Open Office 1 1 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & I IOP-LP Facilities 281 N. College Open Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & (1/2) 4L IOP-LP Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP Sind, 2x4 Reg Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Pell Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Conidor 1 i Retrofitfxture W/ (2) Pi 7Te/TL841/ALTO Lamps, 21 IOP-Sind Bllst, & 2x2 kit Facilities 281 N. College Once 2 2 Retrofit fixture w/(4)F32T8/ADV841/EW/LL/ALTO 28WIamps. 4L IOP LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Open Office 7 7 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 41 IOP LP Facilities 281 N. College Open Office 1 0 Sensor Spec CUS2000 1 Facilities 281 N. College Office 4 4 Retrofit fixture W/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Sind, 2x4 Refi Facilities 281 N. College Office 1 i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Stnd, 2x4 Rag Facilities 281 N. College Office 1 1 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28WIamps&1L IOP-LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR i Facilities 281 N. College Open Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 31 IOP LP Facilities 281 N. College Open Office 1 0 Sensor Spec CIR 1 Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP Sind, 2x4 Refl Facilities 281 N. College Office i 1 Retrofit fixture w/ (2) F1778,71-841/ALTO Lamps, 21 IOP-Sind BIIst, & 2x2 kit Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP Sintl, 2x4 Refi Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W ]amps, 21 IOP Sind, 2x4 ReFl Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Copy 4 4 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28WIamps, 4L IOP LP Facilities 281 N. College File Room 3 3 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps, (1/3)3L IOP-LP, 4'Sockel Pk Facilities 281 N. College File Room 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 6 6 Retrofit fixture wl (2) F17T&TL841/ALTO Lamps, 21. IOP-Stnd Bllst, & 2x2 kit Facilities 281 N. College Copy 2 2 Retrofit fixture w/ (2) F32TWADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Copy 2 0 No Retrofit at this time Attachment #1 - City-wide Lighting Scope Group Site Name Area Description fills Exist Fixts Proposed Retrofit Description Sensor Type Sensor Qty Facilities 281 N. College Copy t 0 Sensor Spec WSIR 1 Facilities 281 N. College Conidor 4 0 No Retrofit at this time Facilities 281 N. College Corridor 4 0 No Retrofit at this time Facilities 281 N. College Corridor 1 1 Retrofit fixture w/ (2) FI7T8fTL841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities 281 N. College Office 3 3 Retrofit fixture w/(2)F32T8/ADV84t/EW/LUALT028W lamps &2L I0P-LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-LP. 4' Centering Kit Facilities 281 N. College Office 1 1 Retrofilfxture w/ (1) F32T8/ADV841/EWILL/ALTO 28W lamps & IL IOP-LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR-2P 1 Facilities 281 N. College Office 6 6 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stnd Mist, & 2x2 kit Facilities 281 N. College Storage 2 0 No Retrofit at this time Facilities 281 N. College Storage 2 2 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Facilities 281 N. College Entry 1 1 Replace Lamp w/ 20W Screw in CIF Facilities 281 N. College Condor 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stud, & 2x4 Reg Facilities 281 N. College Corridor 1 0 No Retrofit at this time Facilities 281 N. College Corridor 2 2 Install new Green LED Exit w/ Battery Back up Facilities 281 N. College Worsen RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Stnd, delamped Facilities 281 N. College Mans RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP Stnd, delamped Facilities 281 N. College Phone 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/WALTO 28W lamps, 2L IOP Smd, & 2x4 Pet! Facilities 281 N. College Locker Room 2 0 No Retrofit at this time Facilities 281 N. College Locker Room 2 0 No Retrofit at this time Facilities 281 N. College Open Once 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Sind, 2x4 Fell Facilities 281 N. College Open Office 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Open Office 3 3 Retrofitfxture w/ (2) F17T87rL841/ALTO Lamps, 2L IOP-Stnd Bllst, & 2x2 kit Facilities 281 N. College Private Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Fell Facilities 281 N. College Pnvate Office 1 0 Sensor Spec WSIR i Facilities 281 N. College Hail 1 1 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stud Mist, & 2x2 kit Facilities 281 N. College Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Red Facilities 281 N. College Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV&41/EW/LUALT0 28W lamps, 21, IOP Sind, 2x4 Refi Facilities 281 N. College Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Refs Facilities 281 N. College Open Once 9 9 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sing, 2x4 Red Facilities 281 N. College Private Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Reis Facilities 281 N. College Private Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Open Office 4 4 Retrofit fixture w/ (2) F32T8/ADV84VEW/LUALT0 28W lamps, 2L IOP Bind, 2x4 Refi Facilities 281 N. College Open Office 7 7 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28WIamps, 4L I0P LP Facilities 281 N. College Private Once 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/WALTO 28W lamps, 2L IOP Sind, 2x4 Red Facilities 281 N. College Private Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Red Facilities 281 N. College Private Office 1 0 Sensor Spec WSIR t Facilities 281 N. College Private Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LL/ALTO 28W lamps. 4L IOP LP Facilities 281 N. College Hall 2 2 Retrofilfxture w/ (2) F17T87fL841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sintl, 2x4 Red Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps & 3L IOP LP Facilities 281 N. College Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps &3L I0P LP Facilities 281 N. College Office 1 0 Sensor Spec WSUS i Facilities 281 N. College Open Office 12 12 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 31 IOP LP Facilities 281 N. College Open Office 2 2 Retrofit fixture w/ (3) F32T6/ADV841/EW/LUALTO 28W lamps & 3L OF LP (Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixus Exist Fixts Proposed Retrofit Description Sensor Type Sensor Oty Facilities 281 N. College Copy 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Stud. 2x4 Pen Facilities 281 N. College Copy 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Kitchen 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Plans Storage 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sure, 2x4 Ben Facilities 281 N. College Plans Storage 1 0 Sensor Spec CIR i Facilities 281 N. College Copy 2 2 Retrofit fixture w/ (2) F32T8/AOV841/EW/LUALTO 28W lamps, 2L IOP Said, Delamped Facilities 281 N. College Copy 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Facilities 281 N. College Open Office 9 9 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Open Once 1 0 Sensor Spec CDT1000 1 Facilities 281 N. College Storage 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L POP LP Facilities 281 N. College Storage 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities 281 N. College Office 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L POP LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR i Facilities 281 N. College Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W Iamps & 3L IOP LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR t Facilities 281 N. College Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28WIamps&3L OF LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR t Facilities 281 N. College Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L POP Sand, & 2x4 Ref! Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Pen Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP - Dual Swltche( Facilities 281 N. College Once 1 0 Sensor Spec WSIR-2P 1 Facilities 281 N. College Open Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities 281 N. College Open Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stud, & 2x4 Ron Facilities 281 N. College Open Office 3 0 No Retrofit at this time Facilities 281 N. College Office 2 2 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28WIamps, (2) 2L IOP LP - Dual Svdtche( Facilities 281 N. College Office 1 0 Sensor Spec WSIR-2P i Facilities 281 N. College Office 2 2 Retrofit Wore w/(4)F32T8(ADV841/EWILUALTO 28WIamps,(2) 2L IOP LP - Dual Svntche( Facilities 281 N. College Office 1 0 Sensor Spec WSIR-2P 1 Facilities 281 N. College Break Rm 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W Iamps. 2L IOP Sind. & 2x4 Reg Facilities 281 N. College Break Rm 1 1 Retrofitfxture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L POP Stnd, & 2x4 Ran Facilities 281 N. College RR - 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities 281 N. College RR 1 0 Sensor Spec WSIR 1 Facilities 281 N. College RR 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities 281 N. College RR 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP - Dual Switche( Facilities 281 N. College Office 1 1 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP - Dual Swltche( Facilities 281 N. College Office 1 0 Sensor Spec WSIR-2P 1 Facilities 281 N. College Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W]amps, (2) 2L POP LP- Dual Swisher Facilities 281 N. College Office 1 0 Sensor Spec WSIR-2P 1 Facilities 281 N. College File Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L OF Stnd, & 2x4 Ran Facilities 281 N. College Open Office 11 11 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W Iamps & 3L IOP LP Facilities 281 N. College Office 3 3 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28WIamps&3L IOP LP Facilities 281 N. College Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28Wlamps & 3L OF LP Attachment #1 - City-wide Lighting Scope Facilities 281 N. College Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities 281 N. College Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities 281 N. College Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities 281 N. College Once 2 2 Retrofit fixture w/(3)F32T8/ADV8411EWILUALTO 28W lamps &3L IOP LP Facilities 281 N. College Office 2 2 Retrain fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Mach Rm 4 4 Install new3L 13W OF Drum Facilities 281 N. College Open Office 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, & 2x4 Refl Facilities 281 N. College Conference 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, & 2x4 Ran Facilities 281 N. College Conference 1 1 Retrofit fixture w/ (2) F32T8/ADVMVEW/ L/ALTO 28W lamps, 2L IOP Stud, & 2x4 Roll Facilities 281 N. College Conference 1 0 Sensor Spec WSIR Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Star, & 2x4 Re0 Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Once 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Stud, & 2x4 Refs Facilities 281 N. College Once 1 0 Sensor Spec VVSIR Facilities 281 N. College Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps. 2L IOP Stnd,&2x4 Bell Facilities 281 N. College Once 1 0 Sensor -Spec WSIR Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Stnd, & 2x4 Bell Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Once 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd. & 2x4 Bell Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP Sind, & 2x4 ReFl Facilities 281 N. College Office 1 0 Sensor Spec CIR Facilities 281 N. College O(Tce 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stud, & 2x4 ReFl Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Hall 1 0 No Retrofit at this time Facilities 281 N. College HC RR 1 1 Retrofilfixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Mens RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Stnd, delamped Facilities 281 N. College Womens RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sind, delamped Facilities 281 N. College Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sind, delamped Facilities 281 N. College Atrium 5 5 Install new t00W CMH Can (High Height) Facilities 281 N. College Atrium 1 1 Install new Green LED Exit w/ Battery Back up Facilities 281 N. College Atrium 6 0 No Retrofit at this time Facilities 281 N. College Atrium 10 10 Install New 42W OF Can (High) Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stud, & 2x4 Fell Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, & 2x4 Bell Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Phone 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Roll Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F17T8/fL841/ALTO Lamps. 2L IOP-Sind Bllst, & 2x2 kit Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Stnd, & 2x4 Refs Facilities 281 N. College Storage 1 0 Sensor Spec WSIR Facilities 281 N. College Entry 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Facilities 281 N. College Office 3 3 Retrofit fixture w/ (2) F32T8/ADV84VEW/LUALTO 28W Iamps, 2L IOP Stnd. & 2x4 ReFl Facilities 281 N. College Conference 4 4 Retrofitfxture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Stnd. & 2x4 Bell Facilities 281 N. College Conference 3 3 Retrofit fixture w/ (2) Fl7T8/rL841/ALTO Lamps, 2L IOP-Sind Sllst, & 2x2 kit Facilities 281 N. College Conference 1 0 Sensor Spec CIR F, Johnson Contirds DELEGATION OF AUTHORITY The undersigned, President of Johnson Controls, Inc., a Wisconsin corporation, pursuant to the authority vested in him by a certain resolution adopted by the Board of Directors of the Company on January 23, 1980, hereby authorizes Bruno A. Biasiotta Vice President & GM Solutions, North America Building Efficiency - Milwaukee 507 E. Michigan Street Milwaukee, WI 53202 to perform, on behalf of the Company, the acts described below: To execute and deliver any and all contracts for the performance of work, sale of goods, and furnishing of services, and any other instruments in connection therewith and in the ordinary course of business. This authority does not extend to: a. the execution of surety, performance or bid bonds; b. the signing of any notes, contracts, or any other agreement to borrow money in the name of the Company; C. the signing, on behalf of the company, of any deeds, abstracts, offers to purchase or any other instruments pertaining to the purchase or sale of real property; and This authority shall remain in full force and effect until October 8, 2008. Signed and sealed at Milwaukee, Wisconsin, this day of April , 2008 `Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fists Proposed Retrofit Description Sensor Type Sensor Qty Facilities 281 N. College Entry 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Office 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sand, & 2x4 Ref Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities 281 N. College Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sind, & 2x4 Ren Facilities 281 N. College Office 2 2 Install new 4' 1 128T8 Wrap - IOP-Sind (Tandem 2L Bllst) Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Said, & 2x4 Reg Facilities 281 N. College Mach Rm 1 1 Install New 2L 13W CF Drum Fixture Facilities 281 N. College Office 3 3 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2)2L IOP LP - Dual Switchec Facilities 281 N. College Copy 1 1 Install new V 2L28T8 Wrap wl Reflector-2L IOP-Stnd ellst Facilities 281 N. College Office 4 4 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP - Dual Switches Facilities 281 N. College Office 1 0 Sensor Spec CIR 1 Facilities 281 N. College Office 4 4 Retrofit fixture w/ (4) F32T8/ADV8411EW/LUALT0 28W lamps, (2) 2L IOP LP- Dual Switches Facilities 281 N. College Office 1 0 Sensor Spec WSIR-2P 1 Facilities 281 N. College Storage 1 t Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sand, & 2x4 Refl Facilities 281 N. College Storage 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 4 4 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28WIamps,(2) 2L IOP LP - Dual SWtchec Facilities 281 N. College Office 1 0 Sensor Spec WSIR-2P i Facilities 281 N. College Office 3 3 Retrofit fixture w/(4)F32T8/ADV84t/EW/LUALT028W lamps, (2) 2L IOP LP - Dual Switche( Facilities 281 N. College Office 1 0 Sensor Spec WSIR-2P t Facilities 281 N. College Phone 2 2 Retrofitfxture w/ (2) F32T8/ADV84t/EW/LUALT0 28W lamps & 2L IOP-LP Facilities 281 N. College Conference 4 4 Retrofitfxlure w/ (4) F32T8/ADV841/EW/LUALTO 28W Iamps, (2) 2L IOP LP- Dual Switchec Facilities 281 N. College Conference t 0 Sensor Spec WSIR-2P 1 Facilities 281 N. College Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd. & 2x4 Reg Facilities 281 N. College Storage 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Corridor 2 2 Retrofit fixture w/ (2) F32TWADV841/EW/LUALTO 28W lamps, 2L IOP Sand, & 2x4 Reg Facilities 281 N. College Janitor 1 1 Install new 2L 13W CF Drum Fixture Facilities 281 N. College RR 1 1 Install new 2' Vanity Fixture w/ (2) F17TSITI- IECO Iamps- OHE LP Bilst Facilities 281 N. College RR 1 1 Retrofit fixture w/ (2) F17T8/71-841/ALTO Lamps & 2L IOP-LP Blet Facilities 281 N. College Open Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Said, & 2x4 Reg Facilities 281 N. College Open Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stan, 2x4 Reg Facilities 281 N. College Corridor 2 0 No Retrofit at this time Facilities 281 N. College Conference 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps, 1L & 2L IOP LP Facilities 281 N. College Conference 1 0 Sensor Spec WSIR-21` 1 Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Refl Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Copy 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/I-UALT0 28W Iamps, 2L IOP Sind, 2x4 Reg Facilities 281 N. College Copy 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Open Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALT028W lamps& 2L IOP-LP Facilities 281 N. College Office 2 2 Retrofit Wore w/(2)F32T8/ADV841/EW/LUALTO 28Wlamps&2L IOP-LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR t Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Office 1 1 Retrofitf lure w/ (2) F32T8/ADV84i/EW/LUALTO 28Wlamps & 2L IOP-LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV84VEWILUALTO 28W lamps, (0.5) 4L IOP Sind, & 2x4 Refl Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Facilifies 281 N. College Office 2 2 Retrofit fixture w/ (2) F32TWADV841/EW/LUALTO 28W lamps. (0.5) 4L IOP Stud, & 2x4 Ran Facilities 281 N. College Office 1 0 Sensor Spec WSIR 1 Attachment #1 - City-wide Lighting Scope Facilities 281 N. College Office 2 2 Retrofitfxture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OF Sind, 2x4 Ref Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Corridor 4 4 Install new 2128T8 Wrap -IOP-Sind Facilities 281 N. College Corridor 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Strict, & 2x4 Ref Facilities 281 N. College Condor 1 1 Retrofit fixture w/ (2) F32T8/ADV8411EWILUALTO 28W lamps, 2L IOP Stnd, & 2x4 Ref Facilities 281 N. College Conifer 1 1 Install new Green LED Exit w/ Battery Back up Facilities 281 N. College Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd. & 2x4 Ref Facilities 281 N. College Worriers RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L 10P Send, & 2x4 Retl Facilities 281 N. College Mans RR 1 1 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W Iamps, 2L IOP Sind, & 2x4 Ref Facilities 281 N. College Break R. 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Corridor 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Corridor 3 3 Replace lamp w/ 16W R30 Screw in CF Facilities 281 N. College Office 2 2 Retrofit fixture wf (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Office 2 2 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28WIamps&2L lOP-LP Facilities 281 N. College Once 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&21 IOP-LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Open Office 9 9 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28Wiamps&2IOP-LP Facilities 281 N. College Open Office 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities 281 N. College Open Office 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28Wiamps&2L I0P-LP Facilities 281 N. College Open Office 2 0 No Retrofit at this time Facilities 281 N. College Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Ref Facilities 281 N. College Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28Wlamps, 2L IOP Sind, 2x4 Ref Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Office 2 2 Retrofit f dure w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Surd, 2x4 Ref Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L Clo Sind. 2x4 Ref Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L 1OP Sind, 2x4 Ref Facilities 281 N. College Office 1 0 Sensor Spec WSIR Facilities 281 N. College Open Once 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Ref Facilities 281 N. College Open Office 4 0 No Retrofit at this time Facilities 281 N. College Conference 2 2 Retrofitfixture w/ (2) F32T8/ADV841/EW/LUALTO 28W Iamps & (1/2) 4L IOP-LP Facilities 281 N. College Conference 1 0 Sensor Spec WSIR Facilities 281 N. College Office 2 2 Retrofit fixture W/ (3) F32T8/ADV8411EW/LUALT0 28W Iamps, iL & 2L IOP LP Facilities 281 N. College Office 1 0 Sensor Spec CIR Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, (0.5) 4L IOP Slnd, & 2x4 Refl Facilities 281 N. College Once 2 2 Retrofit fixture w/ (2) F32T8/AOV84VEW/LUALT0 28W lamps, 2L IOP Stnd, 2x4 Ref Facilities 281 N. College Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Smd, 2x4 Refl Facilities 281 N. College Stairs 1 1 Install new 4128T8 Decorative Surfed mount Fixture - IOP-Stnd Facilities 281 N. College Corridor 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, & 2x4 Ref (Attachment #1 - City-wide Lighting Scope croup site Name Area Description Fixts Exist Fods Proposed Retrofit Description Sensor Type Facilities 281 N. College Elevator 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028WIamps&2L I0P-LP Facilities 281 N. College Exterior 3 0 No Retrofit at this time Facilities 281 N. College Exterior 2 0 No Retrofit at this time facilities 281 N. College Exterior 2 0 No Retrofit at this time Facilities 281 N. College Exterior 3 0 No Retrofit at this time Facilities 281 N. College Atrium Vending 1 0 Sensor Spec VEND MISER - Facilities City Park Bath Hou=Kitchen 4 4 Retrofilfxlure w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Bath Hou! Kitchen 1 i Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & I IOP-LP Facilities City Park Bath Hour Concessions 4 4 Retrofit fixture w/ (1) F32T8/ADV841 /EW/LL/ALTO 28W lamps, 1L IOP-Stnd, & 4' Centering N Facilities City Park Bath How Concessions 6 6 Retrofit fixture w/ (2) F25T8/71841/ALTO Lamps, IOP-HP Bllst, 6' 2L Industrial Hood Convers Facilities City Park Bath Hou: Concessions 1 1 Retrofit fixture w/ (2) F25T8/TL841/ALTO Lamps, IOP-HP Sllst, 6' 2L Industrial Hood Conveys Facilities City Park Bath How Women's Locker 7 7 Retrofit fixture w/ (2) F25Trv7L841/ALTO Lamps, IOP-HP Sllst, 6' 2L Industrial Hood Convers Facilities City Park Bath How Women's Locker 1 1 Retrofit fixture w/ (2) F25T8/TL841/ALTO Lamps, IOP-HP BIISL 6' 2L Industrial Hood Convers Facilities City Park Bath Hou: Women's Locker 3 3 Retrofit fixture w/ (2) F32TB/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Bath Hou! Women's Locker 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities City Park Bath How Women's Locker 2 2 Install new Green LED Exit w/ Battery Back up Facilities City Park Bath How Women's Locker i 0 No Retrofit at this time Facilities City Park Bath How Women's Locker 1 1 Replace lamp w/ (2) 13W Screw in OF Facilities City Park Bath How Office 2 2 Retrofit Wure w/ (4) F32T8/ADV841/EW/LL/ALTO 28W lamps, 4L IOP LP, & 8' Hooded Intl C Facilities City Park Bath Hou: Custodian 2 2 Retrofit Rama w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Bath How Men's Locker 7 7 Retrofit fixture w/ (2) F25T8/fLe41/ALTO Lamps, IOP-HP Bllst, 6' 2L Industrial Hood Convers Facilities City Park Bath How Men's Locker i 1 Retrofit fixture w/ (2) F25TSITL841/ALTO Lamps, IOP-HP Sllst, 6' 2L Industrial Hood Convers Facilities City Park Bath How Men's Locker 3 3 Retrofit fixture w/(2)F32T8/ADV84VEWILUALTO 28W lamps &2L IOP-LP Facilities City Park Bath How Men's Locker 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &(1/2)4L I0P-LP Facilities City Park Bath How Men's Locker 3 3 Install new Green LED Exit w/ Battery Back up Facilities City Park Bath Houe Men's Locker 1 1 Replace lamp w/ (2) 13W Screw in OF Facilities City Park Bath Hou, Staff Lockers 7 7 Retrofit fixture w/ (2) F25TWTI-841/ALTO Lamps, IOP-HP Slat, 6' 2L Industrial Hood Convers Facilities City Park Bath Hou: Staff Lockers 1 1 Retrofit fixture w/ (2) F25T8,711841/ALTO Lamps, IOP-HP Sllst, 6' 2L Industrial Hood Convers Facilities City Park Bath Houe Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/WALT028W lamps &2L I0P-LP Facilities City Park Bath Hou:OKce 1 0 Sensor Spec WEIR Facilities City Park Bath Hout Lockers 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Bath Hou: Staff RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities City Park Bath Hous Boiler Room 12 12 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Bath How Chemical Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Bath Hou=Boiler Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Bath How Chlorine Storage i i Install new 2L 13W OF Drum Fixture Facilities City Park Bath Hou=. Chlorine Storage 1 1 Install new 2L 13W OF Drum Fixture Facilities City Park Bath How Chlorine Storage 1 i Install new 2L 13W OF Drum Fixture Facilities City Park Bath Hou: Chlorine Storage 1 i Install new 2L 13W OF Drum Fixture Facilities City Park Bath Hou: Mans RR 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALT028W lamps &2L I0P-LP Facilities City Park Bath Hou: Women RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Bath Houe Exterior 2 2 Replace lamp w/ (2) 13W Screw in OF Facilities City Park Bath Hou: Exterior 8 0 No Retrofit at this time Facilities City Park Bath How Exterior 10 0 No Retrofit at this time Facilities City Park Bath Houe Exterior 3 0 No Retrofit at this time Facilities Cemetery Shop Can Ban 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP Suit, & S Socket Plat, Facilities Cemetery Shop Break Room 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stud, Small box Attachment #1 - City-wide Lighting Scope Facilities Cemetery Shop Shop Bays 8 8 Retrofit fixture w/(4)F32T8/ADV84 VEW/LUALT028W lamps, 4L I0P-LP,88'Intlustrial Ho --w •ryv Facilities Cemetery Shop Parts Room 3 3 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP-LP, & 8' Industrial He Facilities Cemetery Shop Office 1 1 Install new4' 2L28T8 Decorative Surface Mount- IOP-Smd Facilities Cemetery Shop Mans RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP Stnd, Small box Facilities Cemetery Shop Wormers RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, delamped Facilities Cemetery Shop Furnace 1 1 Install new 1L 13W CF Drum Fixture Facilities Cemetery Shop Exterior 4 4 Install New 100W Pulse Start Metal Halide Flood Fixture Facilities Cemetery Shop Exterior 1 0 No Retrofit at this time Facilities Cemetery Shop Vending 1 0 Sensor -Spec VEND MISER - Facilities City Hall Hall 11 0 No Retrofit at this time Facilities City Hall Hall 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Hall Hall 1 0 No Retrofit at this time Facilities City Hall Custodian 1 1 Install new 1L 13W CF Drum Fixture Facilities City Hall Corridor 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 31 IOP LP Facilities City Hall Corns., 1 0 No Retrofit at this time Facilities City Hall Boiler 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L I0P-LP Facilities City Hall Boiler 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 21 IOP-Sind, & 8' Socket Plat Facilities City Hall Cable TV Studio 4 0 No Retrofit at this time Facilities City Hall Control Room 2 0 No Retrofit at this time Facilities City Hall Control Room 7 0 No Retrofit at this time Facilities City Hall Control Room 6 0 No Retrofit at this time Facilities City Hall Control Room 1 0 Sensor Spec CUS1000 Facilities City Hall TV Studio 6 0 No Retrofit at this time Facilities City Hall TV Studio 1 0 No Retrofit at this time Facilites City Hall Office 5 5 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP - Dual Switche< Facilities City Hall Office 4 4 Retrofit fixture wl (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP- Dual Swdchec Facilities City Hall Office 1 1 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2) 21 IOP LP- Dual Swisher Facilities City Hall Office 5 0 No Retrofit at this time Facilities City Hall Office 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps, I [OR LP, & 21 OF LP (Due Facilities City Hall Office 1 0 Sensor Spec WSIR-2P Facilities City Hall Office 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1 L IOP LP, & 21 [OR LP (Dua Facilities City Hall Office 1 0 Sensor Spec WSIR-2P Facilities City Hall Mech Room 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Hall Storage 2 2 Retrofit fxture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Hall Storage 1 1 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps &1L IOP-LP Facilities City Hall Storage 1 1 Retrofit fixture w/ (2) F25T6RL841/ALTO Lamps & 2L I0P-LP Bllst Facilities City Hall Storage 1 1 Retrofit fixture w/ (1) F25T8lTL841/ALTO&1L IOP-LP Facilities City Hall Network Rooms 1 1 Retrofit Wore w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Refi Facilities City Hall Network Rooms 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Stnd, 2x4 Ref (Very C Facilities City Hall Phone Room 10 10 Retrofit fixture w/ (4) 1`32TS/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP- Dual Switchec Facilities City Hall Phone Room 1 1 Retrofit fixture wl (4) F32T8/ADV841/EW/1UALTO 28W lamps, (2) 2L OF LP- Dual Switches Facilities City Hall Phone Room 1 i Retrofit fixture w/ (2) F17T8,71841/ALTO Lamps, 2L IOP-Stnd BIIst, & 2x2 kit Facilities City Hall Hall 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Facilities City Hall Hall 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Hall Shower 1 1 Retrofit fixture w/ (2) 1`17T8/71841/ALTO Lamps, 2L IOPStnd Sllst, & 2x2 kit Facilities City Hall Break Run 2 2 Retrofit fixture w/ (2) F32T6/ADV841/EW/LUALTO 28W lamps, 2L IOP Sbi & 2x4 Rell Facilities City Hall Shower 1 1 Retrofit fixture w/ (2) F17T8/TL841/ALT0 Lamps, 21 IOP-Sind BIIst, & 2x2 kit Attachment #1 - City-wide Lighting Scope broup Site Name Area Description Fixs Exist Fills Proposed Retrofit Description - Sensor T Facilities City Hall Mach Room 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028WIamps&2L I0P-LP Facilities City Hall Mech Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Sind, & 8' Socket Plat Facilities City Hall Elevator Mech 1 1 Install new 4' 2L28T8 Strip - IOP-Stud Facilities City Hall Electrical 4 4 Retrofit fixture w/ (2) F32T81ADV841/EW/LUALTO 28W lamps & 2L I0P-LP Facilities City Hall Womens RR 4 4 Retrofit fixture w/ (2) F32T8/ADV8411EWILUALTO 28W lamps & (1/2) 4L IOP-LP Facilities City Hall Mens RR 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/1-UALT0 28W lamps & (112) 4L IOP-LP Facilities City Hall Clerk's Office 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Stud, & 2x4 Refl Facilities City Hall Clerk's Office 19 19 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Said, 2x4 Refl Facilities City Hall Clerk's Office 5 5 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stnd Blet, & 2x2 kit Facilities City Hall Clerk's Office 2 0 Sensor Spec CDT2000 Facilities City Hall Clerk's Once 2 0 No Retrofit at this time Facilities City Hall File Rm 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Hall Conference 7 7 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Strip, 2x4 Pert Facilities City Hall Conference 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Sfnd, & 2x4 Refl Facilities City Hall Conference 1 0 Sensor Spec VVSIR Facilities City Hall Office 2 2 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALTO 28W lamps, 2L IOP Strip, 2x4 Pell Facilities City Hall Office 1 0 Sensor Spec WSIR Facilities City Hall Office 2 2 Retrofit fixture w/ (2) F32T8/AOV84VEW/LUALT0 28W lamps, 2L IOP Stud, 2x4 Fefi Facilities City Hall Office 1 0 Sensor -Spec MIR Facilities City Hall Once 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps. 2L POP Stnd, 2x4 ReFl Facilities City Hall Office 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L I0P Sum, &2x4 Fell Facilities City Hall Office 1 0 Sensor Spec WSIR Facilities City Hall Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Stnd, 2x4 Refl Facilities City Hall Office 1 0 Sensor Spec WSIR Facilities City Hall Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Ship, 2x4 Re0 Facilities City Hall Office 1 i Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Ship, & 2x4 ReFl Facilities City Hall Office 2 2 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stnd Bllst, & 2x2 kit Facilities City Hall Office 1 0 Sensor Spec WSIR Facilities City Hall Office 1 1 Retrofit fixture w/ (2) F17T8,71841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities City Hall Office 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Strip, 2x4 Retl Facilities City Hall Office 1 1 Retrofit fixture w/(2)F32T8/ADV8411EW/LUALT028W lamps, 2L I0P Shri&2x4 Ran Facilities City Hall Office 1 0 Sensor Spec OR Facilities City Hall Supply Room 2 2 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stud Bllst, & 2x2 kit Facilities City Hall Supply Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stud. 2x4 Roll Facilities City Hall Supply Room 1 0 Sensor Spec WSIR Facilities City Hall Break Rm 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Shp, 2x4 Re0 Facilities City Hall Break Rm 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Strip, & 2x4 Fell Facilities City Hall Break Rm 1 0 Sensor Spec CIR Facilities City Hall Corridor 3 3 Retrofit fixture w/ (2) F17T87rL841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities City Hall Corridor 1 0 Sensor Spec CUS1000 Facilities City Hall Corridor 3 3 Retrofit fixture w/ (2) F17T8RL841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities City Hall Corridor 1 1 Retrofit fixture w/ (2) F1 7W-1841 /ALTO Lamps, 2L IOPStnd BIIst, & 2x2 kit Facilities City Hall Corridor 1 0 Sensor Spec CUS2000 Facilities City Hall Corridor 2 0 No Retrofit at this time Facilities City Hall Library 6 6 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities City Hall Library 1 0 Sensor Spec WSIR Facilities City Hall File Rm 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Stnd, & 2x4 Raul Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fixts Proposed Retrofit Description Sensor Type Sensor Qty Facilities City Hall File Rm 1 1 Retrofitfxture w/ (2) F17T8/fI-841/ALTO Lamps, 2L IOP-Stnd Bllst, & 2x2 kit Facilities City Hall File Rm 1 0 Sensor Spec WSDT 1 Facilities City Hall Conference 6 6 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps. 1L OF LP, & 2L IOP LP (Dua Facilities City Hall Conference 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP End, & 2x4 Reg Facilities City Hall Storage 1 0 Sensor Spec TIMER i Facilities City Hall Reception 5 5 Retrofit fixture W (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Red Facilities City Hall Reception 1 1 Retrofit fixture w/ (2) F32T8/ADV84VEW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Refl Facilities City Hall Reception 1 0 Sensor Spec WSLIS 1 Facilities City Hall Reception 1 0 No Retrofit at this time Facilities City Hall Open Offices 11 11 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Red Facilities City Hall Open Offices 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L OF Strip, & 2x4 Red Facilities City Hall Open Offices 2 2 Retrofit fixture w/ (2) F1 7TWI-841 /ALTO Lamps, 2L IOP-Slnd Sllst, & 2x2 kit Facilities City Hall Open Offices 2 2 Retrofit fixture w/ (2) F17TSfrL841/ALTO Lamps, 21 IOP-Stnd Sift, & 2x2 kit Facilities City Hall Open Offices 1 1 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Sind Slat, & 2x2 kit Facilities City Hall Open Offices 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Red Facilities City Hall Open Offices 2 0 Sensor Spec CDT2000 2 Facilities City Hall Copy Room 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities City Hall Copy Room 1 0 Sensor Spec CIR 1 Facilities City Hall Meeting Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Red Facilities City Hall Meeting Roam 1 0 Sensor Spec WSIR 1 Facilities City Hal[ Once 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Strip, 2x4 Fell Facilities City Hall Once 1 0 Sensor Spec WSIR 1 Facilities City Hall Conference 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1 L & 2L IOP LP Facilities City Hall Conference 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1 L & 2L OF LP Facilities City Hall Conference 1 0 Sensor Spec - WSIR-2P 1 Facilities City Hall Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L & 2L OF LP Facilities City Hall Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I & 2L IOP LP Facilities City Hall Office 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I & 2L IOP LP Facilities City Hall Office 1 0 Sensor Spec CIR 1 Facilities City Hall Office 1 1 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, (2) 2L IOP LP- Dual Switchec Facilities City Hall Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Once 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps, l L&2L OF LP Facilities City Hall Office 1 0 Sensor Spec WSIR-2P i Facilities City Hall Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps,(2) 2L IOP LP - Dual Svntchec Facilities City Hall Office 1 0 Sensor Spec WSIR-2P i Facilities City Hall Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L & 2L IOP LP Facilities City Hall Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps, 1L & 2L IOP LP Facilities City Hall Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Office 2 2 Retrofit fixture w/ (3) F32T8/AOV841/EW/LUALTO 28W lamps, 1L & 2L IOP LP Facilities City Hall Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Office 4 4 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, I & 2L IOP LP Facilities City Hall Office 1 0 Sensor Spec CIR 1 Facilities City Hall Break Rm 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd. 2x4 Red Facilities City Hall Break Rm 1 0 Sensor Spec WSIR 1 Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fists Exist Fixts Proposed Retrofit Description Sensor T Facilities City Hall Open Offices 7 7 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Rell Facilities City Hall Open Offices 1 i Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities City Hall Open Offices 1 1 Retrofit fixture w/ (2) F17T8/fL841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities City Hall Open Offices 1 0 Sensor Spec CDT2000 Facilities City Hall Open Offices 2 0 Sensor Spec CIR Facilities City Hall Supply Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Refl Facilities City Hall Supply Room 1 1 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stud SIISL & 2x2 kit Facilities City Hall Supply Room 1 0 Sensor Spec CIR Facilities City Hall Corridor 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Re8 Facilities City Hall Corridor 1 1 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Sind Blist, & 2x2 kit Facilities City Hall Corridor 1 0 Sensor Spec WSUS Facilities City Hall Supply Room 2 2 Retrofit fixture w/ (2) F32T8/ADVS41/EW0.UALTO 28W lamps, 2L IOP Sind, 2x4 Bell Facilities City Hall Supply Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Fell Facilities City Hall Supply Room 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & 2x4 Refi Facilities City Hall Supply Room 1 0 Sensor Spec TIMER Facilities City Hall Conference 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Fell Facilities City Hail Conference 1 0 Sensor Spec WSIR Facilities City Hall Corridor i 1 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALT0 28W lamps, 2L IOP StndT 2x4 Refi Facilities City Half Conidor 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sind, & 2x4 Refl Facilities City Hall Condor 2 2 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stnd BIIst, & 2x2 kit Facilities City Hall Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps. 2L IOP Sind, 2.4 Refi Facilities City Hall Office 1 0 Sensor Spec WSIR-2P Facilities City Hall Conference 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EVV/LUALT0 28W lamps, 2L IOP Sind, 2x4 Reil Facilities City Hall Conference 1 0 Sensor Spec CIR Facilities City Hall Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Fell Facilities City Hall Office 1 0 Sensor Spec WSIR-2P Facilities City Hall Office 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Surd, 2x4 Roll Facilities City Hall Office 1 0 Sensor Spec CIR Facilities City Hall Once 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Ran Facilities City Hall Office 1 0 Sensor Spec WSIR Facilities City Hall Supply Room 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stud, 2x4 Re8 Facilities City Hall Supply Room 1 0 Sensor Spec CIR Facilities City Hall Corridor 8 e Retrofit fixture w/ (2) Fl7T8rrL841/ALTO Lamps, 2L IOP-Sind BIIst, & 2x2 kit Facilities City Hall Conidor 2 0 Sensor Spec CUS1000 Facilities City Hall Corridor 4 4 Install new Green LED Exit w/ Battery Back up Facilities City Hall Vault e 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Pell Facilities City Hall IT Room 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Refl Facilities City Hall IT Room 7 7 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Sind, 2x4 Bell Facilities City Hall IT Room 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Hall IT Office 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Sind, 2x4 Refi Facilities City Hall IT Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP Sind, 2x4 Bell Facilities City Hall IT Office 1 0 Sensor Spec WSIR Facilities City Hall IT Office 1 i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Bell Facilities City Hall IT Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sind, & 2x4 Refl Facilities City Hall IT Office 1 i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Fell Facilities City Hail IT Office 1 0 Sensor Spec WSIR Facilities City Hall IT Office 1 1 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Reif Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Finds Exist Fixts Proposed Retrofit Description Sensor Type Sensor Qty Facilities City Hall IT Office 1 0 Sensor Spec WSIR 1 Facilities City Hall IT Office i i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stud, 2x4 Rea Facilities City Hall IT Office 1 0 Sensor Spec WSIR 1 Facilities City Hall IT Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Shut, 2x4 Refi Facilities City Hall IT Office 1 0 Sensor Spec WSIR 1 Facilities City Hall IT Office 1 1 Retrofit fixture w/ (2) F32TB/ADV841/EW/LUALTO 28W lamps, 2L IOP Stri 2x4 Refl Facilities City Hall IT Office 1 0 Sensor Spec WSIR t Facilities City Hall Stairs 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP S(nd, 2x4 Rea Facilities City Hall Stairs 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sind, 2x4 Rea (Very F Facilities City Hall Stairs 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Hall Open Offices 6 6 Retrofilfixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Stud, 2x4 Rea Facilities City Hall Open Offices i i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sind. & 2x4 Refi Facilities City Hall Open Offices 1 1 Retrofit fixture w/ (2) F17T8/fL841/ALTO Lamps, 2L IOP-Stud Bllst, & 2x2 kit Facilities City Hall Open Offices 1 0 Sensor Spec CDT1000 1 Facilities City Hall Open Offices 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Hall Office, 1 1 Retrofit fixture wl (3) F32T8/ADV841/EW/LL/ALTO 28W lamps, I IOP LP, & 2L IOP LP (Dua Facilities City Hall Office 1 1 Retrofit fixture W (3) F32T8/ADV841/EW/LUALTO 28W [amps, l L & 2L I0P LP Facilities City Hall Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps, it & 2L IOP LP Facilities City Hall Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Mayor Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L & 2L IOP LP Facilities City Hail Mayor Office 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps, 1L & 2L IOP LP Facilities City Half Mayor Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Mayor Office Cent 2 2 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALT0 28W lamps, 2L IOP Stud, 2x4 Rea Facilities City Hall Mayor Office Cent 1 0 Sensor Spec WSIR 1 Facilities City Hall Conference 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Rea Facilities City Hall Conference 1 0 Sensor Spec WSIR i Facilities City Hall Office 2 0 No Retrofit at this time Facilities City Hall Office 1 1 Retrofit fixture w/(4)F32T8/ADV841/EW/LL/ALT028W lamps. 4L IOP LP Facilities City Hall Office 1 0 Sensor Spec WSIR t Facilities City Hall Corridor 3 3 Retrofit fixture w/ (2) F17TWI-841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities City Hall Corridor 1 0 Sensor Spec CUS1000 t Facilities City Hall Office 2 2 Retrofit fixture w/ (3) F32T8/ADV84t/EW/LUALTO 28W lamps, 1L & 2L IOP LP Facilities City Hall Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Office 2 2 Retrofit fixture w/ (3) F32T8/ADV84t/EW/LUALTO 28W lamps, 1L & 2L IOP LP Facilities City Hall Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Open Offices 7 0 No Retrofit at this time Facilities City Hall Open Offices 4 4 Retrofit fixture w/(2)F32TB/ADV641/EW/LUALT028W lamps &2L I0P-LP Facilities City Hall Open Offices 3 0 No Retrofit at this time Facilities City Hall Open Offices 2 0 Sensor Spec CDT2000 2 Facilities City Hall Open Offices 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Hall Office 2 0 No Retrofit at this time Facilities City Hall Office 1 1 Retrofit fixture w/ (4) F32T8/ADV84l/EW/LUALTO 28W lamps, 4L IOP LP Facilities City Hail Office 1 0 Sensor Spec WSIR 1 Facilities City Hall Office 2 0 No Retrofit at this time Facilities City Hall Office 1 1 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities City Hall Office 1 0 Sensor Spec WSIR 1 Facilities City Hall Once 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps. i L& 2L I0P LP Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Pixts Proposed Retrofit Description Sensor Type Sensor Qty Facilities City Hall Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Office 6 0 No Retrofit at this time Facilities City Hall Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Facilities City Hall Office 1 0 Sensor Spec WSIR-21` 1 Facilities City Hall Conference 3 3 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALT028W lamps, l L&2L IOP LP Facilities City Hall Conference 1 1 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALT028W lamps, l L&2L IOP LP Facilities City Hall Conference 1 0 Sensor Spec VJSIR-2P i Facilities City Hall Conference RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Stud, 2x4 Re0 Facilities City Hall Conference RR 1 0 Sensor Spec WSIR 1 Facilities City Hall Storage 1 1 Install new 2L 13W CF Drum Fixture Facilities City Hall Lobby 12 0 No Retrofit at this time Facilities City Hall Lobby 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Hall Women; RR 4 4 Retrofit fixture w/ (2) 1`32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities City Hall Roof Access 1 1 Install new 3L 13W OF Drum Facilities City Hall Copy Room 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & t1/2) 4L IOP-LP Facilities City Hall Copy Room 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities City Hall Mons RR 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities City Hall Main Lobby 17 0 No Retrofit at this time Facilities City Hall Main Lobby 2 0 No Retrofit at this time Facilities City Hall Main Lobby 2 2 Install new Green LED Exit w/ Battery Back up Facilities City Hall Main Lobby 6 6 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP Sure, & 8' Socket cla4 Facilities City Hall Entry 6 0 No Retrofit at this time Facilities City Hall Entry 3 0 No Retrofit at this time Facilities City Hall Conference 17 17 Retrofit fixture w/ (2) F1718/rL841/ALT0 Lamps, 2L IOP-HP Milan, & 2x2 kit (18y Facilities City Hall Conference 11 11 Install new 26W OF Can (Dimmable @ 18') Facilities City Hall Conference 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Hall Conference 1 0 Sensor Spec WCDT1500-W 1 Facilities City Hall Council Chambers 2 2 Retrofilfixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities City Hall Council Chambers 1 i Retrofilfixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W Iamps & 2L IOP-LP Facilities City Hall Council Chambers 10 10 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (112) 4L IOP-LP (Difficult Ins Facilities City Hall Council Chambers 1 1 Relroftfixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP (Difficult Install) Facilities City Hall Council Chambers 5 5 Retrofitfixture w/ (2) F32T8/ADV841/EW/IUALTO 28W lamps & 2L IOP-LP Facilities City Hall Council Chambers 8 8 Install New 42W CF Can (Dimmable) Facilities City Hall Council Chambers 3 3 Install New 42W CF Can (Dimmable & @ 16') Facilities City Hall Council Chambers 8 8 Install New 42W CF Can (Dimmable & @ 16) Facilities City Hall Council Chambers 9 9 Install New 42W OF Can (Dimmable & @ 16') Facilities City Hall Council Chambers 10 10 Install New 42W CF Can (Dimmable & @ 16') Facilities City Hall Council Chambers 30 30 Install New 42W CF Can (Dimmable & (9 16') Facilities City Hall Council Chambers 10 10 Install New 42W CF Can (Dimmable & @ 16') Facilities City Hall Council Chambers 2 2 Install new 1 L 26W CF Directional Can (Dimmable) Facilities City Hall Council Chambers 3 3 Install new Green LED Exit w/ Battery Back up Facilities City Hall Council Chambers 2 0 No Retrofit at this time Facilities City Hall Council Storage i 1 Install New 2L 13W OF Drum Fixture Facififies City Hall Conference 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP Stud, & 4x4 Reflector Facilities City Hall Conference 4 0 No Retrofit at this time Fardlities City Hall Conference 6 0 No Retrofit at this time Facilities City Hall Conference 5 0 No Retrofit at this time Attachment #1 - Citv-wide Liahtina Score Group Site Name Area Description Fills Exist Fixts Proposed Retrofit Description Sensor Type Sensor a Facilities City Hall Conference 1 0 No Retrofit at this time Facilities City Hall RR 1 1 Replace lamp w/ 16W G30 Globe Screw in CF Facilities City Hall Kitchen 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Sind, delampetl Facilities City Hall Computer 3 3 Retrofit fixture wl (3) F32TWADV841/EWILUALTO 28W lamps, 1L & 2L IOP LP Facilities City Hail Computer 1 0 Sensor Spec WSIR-2P 1 Facilities City Hall Exterior 14 14 Install new 2L 13W CF Can (Cold Temperature & Difficult Install) Facilities City Hall Exterior 4 0 No Retrofit at this time Facilities City Hall Exterior 2 0 No Retrofit at this time Facilities City Hall Exterior 4 0 No Retrofit at this time Facilities City Hall Exterior 3 0 No Retrofit at this time Facilities City Hall Hall 1 0 Sensor Spec VEND MISER- 1 Facilities City Park Center Janitor 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Center Hall 4 4 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Sind BIIst, & 2x2 kit Facilities City Park Center Hall 1 0 No Retrofit at this time Facilities City Park Center Hall 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Park Center Football Area 5 5 Retrofit fixture W/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities City Park Center Football Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stud, & 8' Industrial H Facilities City Park Center Football Storage 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUA-TO 28W lamps, 2L IOP-Stand, & 8' Industrial H Facilities City Park Center Pool Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Sind, & B' Industrial H Facilities City Park Center Pool Storage 1 1 Install New 2L 13W CF Drum Fixture Facilities City Park Center Pool Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W [amps & 2L IOP-LP Facilities City Park Center Tube Storage 2 2 Install New 2L 13W CF Drum Fixture Facilities City Park Center Pads Storage 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Sind, & 8' Industrial H Facilities City Park Center Pads Storage 1 1 Install New 2L 13W CF Drum Fixture Facilities City Park Center Shop 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Sind, & 8' Industrial H Facilities City Park Center Garage / Storage 13 13 Install new 4' 1L28T8 Strip - IOP-Sind Facilities City Park Center Pool Pumps 2 2 Retrofit fixture w/ (2) F32TWADV84VEW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities City Park Center Chemical Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Center Upper hall 5 5 Retrofit fixture w/ (2) FWTIOH-841/ALTO Lamps, 2L [OP -Stud Bilsp & 2x2 kit Facilities City Park Center Upper hall 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Park Center Upper hall stairs 3 0 No Retrofit at this time Facilities City Park Center Dance studio 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Sind. & 8' Socket Plat Facilities City Park Center Dance studio 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/WALTO 28W lamps, 2L IOP-Stnd, & 8' Socket Plat Facilities City Park Center Dance studio 10 0 No Retrofit at this time Facilities City Park Center Dance studio 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Center Dance studio 8 8 Install New 2L 13W CF Decorative Drum Fixture (1126BR13-L) Facilities City Park Center Stage 3 0 No Retrofit at this time Facilities City Park Center Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stud, & 8' Socket Plat Facilities City Park Center Women's RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sintl, & 2x4 Rail Facilities City Park Center Women's RR i 1 Install new 2'Vanity Fixture w/(2)F17T8/TL841/ECO lamps-CHE LP Bllst Facilities City Park Center Women's RR 1 0 No Retrofit at this time Facilities City Park Center Women's RR 1 0 Sensor Spec WSIR 1 Facilities City Park Center Men's RR 1 1 Retrofit fixture w/ (2) F32T8lADV841/EW/LUALTO 28W lamps, 2L IOP Sintl, & 2x4 Refl Facilities City Park Center Men's RR 1 1 Instal( new 2' Vanity Fixture w/ (2) F'i 78,71-84VECO lamps -OHE LP Biist Facilities City Park Center Men's RR 1 0 No Retrofit at this time Facilities City Park Center Men's RR 1 0 Sensor Spec WSIR 1 Facilities City Park Center Elevator 1 1 Retrofit Wore w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP 00410 Proposal Bond 00530 Notice to Proceed 00610 Performance Bond 00615 Payment Bond 00630 Certificate of Insurance 00635 Certificate of Substantial Completion 00640 Certificate of Final Acceptance 00650 Lien Waiver Release (CONTRACTOR) 00660 Consent of Surety 00670 Application for Exemption Certificate Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fists Proposed Retrofit Description Sensor Type Sensor Qty Facilities City Park Center Storage 2 2 Install new 4' 1L28T8 Strip- IOP-Sind Facilities City Park Center Exterior 2 0 No Retrofit at this time Facilities City Park Center Exterior- Boat Storage 3 3 Install New 2L 13W CF Drum Fixture Facilities City Park Center Exterior 4 0 No Retrofit at this time Facilities City Park Center Dance Studio 1 0 Sensor Spec VEND MISER- 1 Facilities City Park Golf Cour: Pro Shop B 8 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & 1 L IOP-LP Facilities City Park Golf Cour: Pro Shop 14 0 No Retrofit at this time Facilities City Park Golf Cour. Pro Shop 1 1 Install new Green LED Exit w/ Battery Back up Facilities City Park Golf Cour: Pro Shop 3 3 Replace lamp w/ 16W R30 Screw in CF Facilities City Park Golf Cour: Pro Shop 2 2 Retrofit fixture w/ (2) F32T8lADV841/EW/LL/ALTO 28W lamps, 2L IOP Stnd, 2x4 Deep Ref Facilities City Park Golf Cour Furnace 2 2 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps & (112) 4L IOP-LP Facilities City Park Golf Cour. Hand Carl Storage 4 4 Retrofit fixture w/ (2) F32T8fADV841/EW/LUALT0 28W Iamps, (1/2) 4L IOP Sud, delamped Facilities City Park Golf Cour. Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, delamped Facilities City Park Golf Cour: Office 1 0 Sensor Spec WSIR 1 Facilities City Park Golf Cour. Shoe Storage 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Golf Coun Restaurant 12 12 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28W lamps &1L IOP-LP Facilities City Park Golf Coun Restaurant 7 7 Replace lamp w/ 16W R30 Screw in CF Facilities City Park Golf Cour: Restaurant 2 2 Install new Green LED Exit w/ Battery Back up Facilities City Park Golf Cour Mans RR Vestibule 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Golf Court Mans RR Vestibule 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities City Park Golf Cour Mans RR Vestibule 1 0 Sensor Spec WSIR 1 Facilities City Park Golf Cour: Mans RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities City Park Goff Cour. Mans RR 1 i Replace lamp w/ 16W R30 Screw in CF Facilities City Park Golf Coun Mans RR 1 0 Sensor Spec WSIR 1 Facilities City Park Golf Coun. Concessions 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sud, delamped Facilities City Park Golf Cour. Kichen 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, delamped Facilities City Park Golf Cour Worriers RR Vestibule 1 1 Retrofit w/ (1) 18W CF Hardwire Kit Facilities City Park Golf Cour. Wearers RR Vestibule 1 0 Sensor Spec VVSiR 1 Facilities City Park Golf Cour Worriers RR 2 2 Retrofit Posture w/ (2) F32T8/AOV841/EW/LUALT0 28W lamps & 2L IOP-LP Facilities City Park Golf Cour. Warrens RR 1 1 Retrofit w/ (1) 18W CF Hardwre Kit Facilities City Park Golf Cour. Worriers RR 1 0 Sensor Spec WSIR 1 Facilities City Park Golf Coun Storage Room 2 2 Retrofit fixture w/ (2) 1`32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, delamped Facilities City Park Golf Cour. Storage Room 1 1 Replace Lamp w/ 23W Screw in CF Facilities City Park Golf Cour: Electrical Room 1 1 Replace Lamp w/23W Screw in CF Facilities City Park Golf Cou, Exterior 3 0 No Retrofit at this time Facilities City Park Golf Cour. Exterior 4 4 Replace lamp w/ 13W Screw in CF Facilities City Park Golf Court Exterior 3 0 No Retrofit at this time Facilities City Park Golf Cour: Exterior 5 0 No Retrofit at this time Facilities City Park Golf Cart Carl Barn 8 8 Install new 4' 2L32T8 Strip Fixture- IOP-Sind (Cole Temp) Facilities City Park Golf Cart Cart Barn 2 0 Sensor Spec CUR 2 Facilities City Park Golf Maini Shop 13 13 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L [OR Sind, & 8' Socket Plat, Facilities City Park Golf Monl Shop Office 2 2 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Facilities City Park Golf Mainl Shop Office 1 0 Sensor Spec WSIR 1 Facilities City Park Goff Marl RR 1 1 Retrofit fixture w/ (2) F32TB/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities City Park Golf Marl RR 1 0 No Retrofit at this time Facilities City Park Golf Main! RR i 0 Sensor Spec MIR 1 Facilities City Park Golf Main] Locker 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fixts Proposed Retrofit Description Sensor Type Sensor Qty Facilities City Park Golf Mainl Break Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOP-LP Facilities City Park Golf Main10ffice 2 2 Retrofit fixture w/ (2) F32T8/ADV84t/EW/LUALTO 28W lamps, 2L IOP Stnq & 2x4 Rea Facilities City Park Goff Mainl Office t 0 Sensor Spec WSIR 1 Facilities City Park Golf Barn Barn 3 3 Install new 2L 13W OF Drum Fixture Facilities City Park Golf Barn Barn 4 4 Install new 2L 13W OF Drum Fixture Facilities City Park Golf Barn Barn 1 1 Install new 2L 13W OF Drum Fixture Facilities City Park Golf Barn Barn 1 1 Install new 2L 13W CF Drum Fixture Facilities City Park Golf Barn Upper Barn 3 3 Install new 2L 13W OF Drum Fixture Facilities City Park Golf Cour Vending 1 0 Sensor Spec VEND MISER- 1 Facilities City Park Shop Shop 36 36 Install new & 6LTe lmostdal fixture with uptight- IOP-HP Facilities City Park Shop Shop & Upper Storage 29 29 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Shop Shop 8 8 Retrofit fixture w/ (2) F32T8/ADV84t/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Shop Shop i 1 Install new Green LED Exit Facilities City Park Shop Forestry Office 6 6 Retrofit fixture w/ (2) F32T8/ADV8411EW/LUALT0 28W lamps & 2L IOP-LP Facilities City Park Shop Computer Room 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALT0 28W lamps, 4L [OR LP Facilities City Park Shop Lunch Room 8 8 Retrofit fixture w/(4)F32T8/AOV841/EW/LUALTO 28WIamps, 4L [OR LP Facilities City Park Shop Copy Room 2 2 Retrofit fixture w/(4)F32T8/ADV841/EW/WALTO 28W lamps, 4L IOP LP Facilities City Park Shop Parts Office 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L I0P-LP Facilities City Park Shop Parts Shelves 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Shop Parts Shelves 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L POP -LP Facilities City Park Shop Shop Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Shop Paint Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities City Park Shop Chemical Room 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities City Park Shop Corridor 10 10 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L I0P-LP Facilities City Park Shop Candor 1 1 Install new Green LED Exit Facilities City Park Shop Lobby/Entry 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L I0P-LP Facilities City Park Shop Lobby/Entry 1 1 Install new Green LED Exit Facilities City Park Shop Lobby/Entry 4 0 No Retrofit at this time Facilities City Park Shop Lobby/Entry 1 1 Retrofit fixture w/ (2) F17TWTI-841/ALTO Lamps, 2L IOP-Sind Blist, & 2x2 kit Facilities City Park Shop Women's RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Shop Men's RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Shop Sports Once 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities City Park Shop Sports Office 1 0 Sensor Spec WSIR 1 Facilities City Park Shop Sports Office 1 t Retrofit fixture w/ (2) F32TSIADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities City Park Shop Sports Office 3 3 Retrofit fixture w/ (4) F32TWADVM11EWILUALTO 28W lamps, 4L JOB LP Facilities City Park Shop Sports Office 1 0 Sensor Spec WSIR-2P 1 Facilities City Park Shop Sports Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALT0 28W lamps, 4L IOP LP Facilities City Park Shop Sports Office 1 0 Sensor Spec WSIR 1 Facilities City Park Shop Sports Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALT0 28W tamps, 4L IOP LP Facilities City Park Shop Sports Office 1 0 Sensor Spec WSIR t Facilities City Park Shop Sports Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities City Park Shop Sports Office 1 0 Sensor Spec WSIR 1 Facilities City Park Shop Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L UP LP Facilities City Park Shop Office 1 0 Sensor Spec WSIR 1 Facilities City Park Shop Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALT0 28W lamps & 3L IOP LP Facilities City Park Shop Office 1 0 Sensor Spec WSIR 1 Facilities City Park Shop Office 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L I0P LP Attachment_#1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fixts Proposed Retrofit Description Sensor Type Sensor oty Facilities City Park Shop Office 1 0 Sensor Spec WSIR t Facilities City Park Shop Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L OF LP Facilities City Park Shop Office 1 0 Sensor Spec WSIR t Facilities City Park Shop Office 4 4 Retrofit fixture w/ (4) F32TWADV8411EW/LUALTO 28W lamps, 4L IOP LP Facilities City Park Shop Office 1 0 Sensor Spec WSIR 1 Facilities City Park Shop Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities City Park Shop Office 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUA1-TO 28W lamps, 4L IOP LP Facilities City Park Shop Open Office 7 7 Retrofit fixture w/ (4) F32T8/ADV841/EW/LL/ALTO 28W lamps, 4L IOP LP Facilities City Park Shop Conference 2 3 3 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities City Park Shop Conference 2 t 0 Sensor Spec WSIR 1 Facilities City Park Shop Conference 1 8 0 No Retrofit at this time Facilities City Park Shop Conference 1 6 0 No Retrofit at this time Facilities City Park Shop Conference 1 1 0 Sensor Spec CIR-2R 1 Facilities City Park Shop Conference 1 12 12 Retrofilfixlure w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stud Bllst, & 2x2 kit Facilities City Park Shop Reception 7 7 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP LP Facilities City Park Shop Small Wall packs 6 0 No Retrofit at this time Facilities City Park Shop Jelly Jars 1 t Install New Enertron 7800L 13W CF WP Facilities City Park Shop Shed 3 3 Install New Enertron 7800L 13W CF WP Facilities City Park Shop Large wall pack 1 0 No Retrofit at this time Facilities City Park Shop Main Shop 1 0 Sensor Spec VEND MISER- 1 Facilities City Park Shop Lunch Room 1 0 Sensor Spec VEND MISER- 1 Facilities EPIC Entry Vestible 5 5 Replace lamp w/ 16W R30 Screw in CF Facilities EPIC Main Lobby 22 22 Install new 3L F31T8 2x2 DCP - Sind IOP Bllst (High) Facilities EPIC Main Lobby 2 2 Replace lamp w/ 16W R30 Screw in CF (Difficult) Facilities EPIC Upstairs lobby 27 27 Retrofit fixture w/ (2) F17T8rfL841/ALTO Lamps, 2L IOP-HP BIIst, & 2x2 kit Facilities EPIC Upstairs lobby 6 6 Replace lamp w/ 16W R30 Screw in CF Facilities EPIC Elevator 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Elevator Mech 1 1 Retrofit fixture w/(2)F32T8/ADV84t/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Concessions 5 5 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Concessions 2 2 Install New Enertron 7026L 2L 13W CF WP Facilities EPIC Women's RR 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 21 IOP-LP Facilities EPIC Man's RR 3 3 Retrofit fixture w/(2)F32TB/ADV8411EWILUALTO 28W lamps &2L IOP-LP Facilities EPIC Storage 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Storage 1 0 Sensor Spec WSIR i Facilities EPIC Conference 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Conference 1 0 Sensor Spec WSIR 1 Facilities EPIC Skate Rental 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Skate Rental 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Skate Rental 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Facilities EPIC Skate Rental 1 0 Sensor Spec WSIR 1 Facilities EPIC Day Care 3 3 Retrofit fixture w/(4)F32T8/ADV84t/EW/LUALTO 28W lamps, (2) 2L IOP LP - Dual Swfchec Facilities EPIC Day Care 1 0 Sensor Spec WSIR-2P 1 Facilities EPIC Day Care RR 2 2 Retrofit fixture w/ (2) F32T8/ADV84t/EW/LUALTO 28W lamps & 21 IOP-LP Facilities EPIC Day Care RR 1 0 Sensor Spec WSIR 1 Facilities EPIC Office 3 3 Retrofit fixture w/ (2) F32T6/ADV841/EW/LL/A1.TO 28W lamps, 21 IOP Strip, 2x4 Refl Facilities EPIC Office 1 0 Sensor Spec WSIR 1 Facilities EPIC Kitchen 4 4 Retrofit fixture w/ (2) F32T8/ADV84t/EW/LUALTO 28W lamps, 2L IOP Star, 2x4 Retl Attachment #1 - City-wide Lighting Scope Facilities EPIC Kitchen t 0 Sensor Spec CIR Facilities EPIC Youth Hockey 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind 2x4 Reg Facilities EPIC Youth Hockey t t Retrofit fxture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & 2L IOP-LP Facilities EPIC Youth Hockey t 0 Sensor Spec WSIR Facilities EPIC Youth Hockey Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Youth Hockey Office 1 0 Sensor Spec WSIR Facilities EPIC Rob Coordinator 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L [OR Sind, 2x4 Refi Facilities EPIC Rec Coordinator 1 0 Sensor Spec CIR Facilities EPIC Meeting A 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stnd, 2x4 Refi Facilities EPIC Meeting A 2 0 Sensor Spec CIR Facilities EPIC Meeting B 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Strict, 2x4 Reg Facilities EPIC Meeting 1 0 Sensor Spec CIR Facilities EPIC Exercise Room 12 12 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilites EPIC Exercise Room 1 0 Sensor Spec CIR Facilities EPIC Mech Rm 2 2 Retrofit fixture w/ (2) F32T8/ADV84 /EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Hall 9 9 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Hall t 1 Install new Red LED Exit w/ Battery Back up Facilities EPIC Hockey Locker 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L OF Ski &delamped Facilities EPIC RR/Shower 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stri & delamped Facilities EPIC Locker 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind. & delamped Facilities EPIC Lock.,C 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, & delamped Facilities EPIC RR/Shower 2 2 Retrofit fixure w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps, 2L IOP Sind, & delamped Facilities EPIC Locker D 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind. & delamped Facilities EPIC Old Rink 42 0 No Retrofit at this time Facilities EPIC Old Rink e 0 No Retrofit at this time Facilities EPIC Old Rink 4 4 Install new Red LED Exit w/ Battery Back up Facilities EPIC Old Rink 1 0 No Retrofit at this time Facilities EPIC Old Rink Stands 14 14 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP (Difficult Install) Facilities EPIC Old Rink Stands t i Retrofit fixture w/ (2) F32T8/ADV84t/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Boiler Rm 2&3 15 15 Retrofit fixture wl(2)F32T8/ADV84t/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Boiler For Office 3 3 Retrofit fixture w/(2)F32T8/ADV84t/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Old Zambom Room B 8 Retrofit fixture w/(2)F32T8/ADV84t/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Cust Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &(112)4L IOP-LP Facilities EPIC Cust Office 1 1 Retrofit fixture w/(2)F32T8/ADV84t/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Storage 2 2 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 41 IOP Sind & 8- Socket Plat Facilities EPIC New Rink 44 0 No Retrofit at this time Facilities EPIC New Rink 9 0 No Retrofit at this time Facilities EPIC New Rink 4 0 No Retrofit at this time Facilities EPIC New Rink 14 14 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC New Rink 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUA1-TO 28W lamps & 2L IOP-LP Facilities EPIC Concessions Lobby 6 6 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L [OR LP Facilities EPIC Concessions Lobby 1 0 Sensor Spec CIR Facilities EPIC Skate staff 6 6 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities EPIC Skate staff 1 0 Sensor Spec CIR Facilities EPIC Skate staff Kitchen 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Skate staff RR 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2IOP-LP Facilities EPIC Skate staff Storage 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Attachment #1 - City-wide Lighting Scope Droup Site Name Area Description Fiats Exist Fixts Proposed Retrofit Description -- - Sensor l Facilities EPIC First Aid 1 1 Retrofit fixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities EPIC First Aid 1 0 Sensor Spec WSIR Facilities EPIC Ref Office 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L IOP LP Facilities EPIC Ref RR 1 1 Retrofit fixture w/ (2) 1`32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities EPIC Ref RR 1 0 No Retrofit at this time Facilities EPIC Skate Sharpening 2 2 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Facilities EPIC Corridor 2 2 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Corridor 1 0 No Retrofit at this time Facilities EPIC Storage 6 6 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L IOP-LP Facilities EPIC Ext Storage 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALT028W[amps &2L IOP-LP Facilities EPIC Conditioning A 8 e Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Conditioning 1 0 Sensor Spec CIR Facilities EPIC Conditioning B 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities EPIC Conditioning 1 0 Sensor Spec CIR Facilities EPIC RR 1 i Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC RR 2 0 No Retrofit at this time Facilities EPIC RR 2 0 No Retrofit at this time Facilities EPIC RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Rep Supervisor 4 4 Retrofit fixture w/(3)F32T8/ADV841/EW/LUALTO 28W lamps &3L IOP LP Facilities EPIC Storage 1 1 Retrofit fixture w/(2)F32TB/ADV841/EW/LUALT028W lamps &2L IOP-LP Facilities EPIC Locker A 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities EPIC RR 2 2 Retrofit fixture wl (2) F32T8/ADV641/EW/LUALTO 28W tamps & 2L IOP-LP Facilities EPIC RR 3 0 No Retrofit at this time Facilities EPIC Locker B 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Locker C 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC RR 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC RR 3 0 No Retrofit at this time Facilities EPIC Locker 6 6 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Women's Locker 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Women's Locker 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Women's Locker 2 0 No Retrofit at this time Facilifes EPIC Zamboni Storage 16 16 Retrofit Were w/(2)F32T8/AOV841/EWILUALT028WIamps&2L IOP-LP Facilities EPIC Upper Locker 8 8 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALT028W [amps &2L IOP-LP Facilities EPIC Upper Meeting Ran 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W [amps & 2L IOP-LP Facilities EPIC Upper Meeting Rm 2 0 No Retrofit at this time Facilities EPIC Upper Meeting Rm 1 0 Sensor Spec WSIR-2P Facilities EPIC Maint Office 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & (1/2) 4L IOP-LP Facilities EPIC Mech Rm 121 2 2 Retrofilfixture w/ (2) F32T8/ADV841/EWILUALTO 28W lamps & (112) 4L IOP-LP Facilities EPIC Mach Run 121A 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps & (1/2) 4L IOP-LP Facilities EPIC Janitor 116A 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities EPIC Corridor 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALT028W lamps &2L IOP-LP Facilities EPIC Corridor 1 0 No Retrofit at this time Facilities EPIC Storage 122 4 4 Retrofit fixture w/ (2) F32TS/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Hall West 10 10 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W[amps &2L IOP-LP Facilities EPIC Hall West 1 1 Install new Red LED Exit w/ Battery Back up Facilities EPIC Corridor 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Attachment #1 - City-wide Liahtina SCODe Group Site Name Area Description Fixts Exist Fists Proposed Retrofit Description Sensor Type Sensor oty Facilities EPIC Office 1 0 Sensor Spec WSIR 1 Facilities EPIC Locker Ran- Men's Staff 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 ]OR -LP Facilities EPIC Locker Rho-Men's Staff 1 0 Sensor Spec WSUS 1 Facilities EPIC Locker Rm - Women'. Sta 2 2 Retrofit fixture w/ (2) F32T8/ADV84 VEW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Locker Rm - Women's St: 1 0 Sensor Spec WSUS 1 Facilities EPIC Office 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Office 1 0 Sensor Spec WSIR 1 Facilities EPIC Office Per 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Office Pool 3 0 No Retrofit at this time Facilities EPIC Office Pool 1 0 Sensor Spec CIR 1 Facilities EPIC Office 2 2 Retrofit fixture w/(2)F32T8/AOVM11EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Office 1 0 Sensor Spec WSIR 1 Facilities EPIC Family Changing Room 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Family Changing Room 1 0 Sensor Spec WSIR 1 Facilities EPIC Women's Locker 17 17 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Women's Locker 1 0 No Retrofit at this time Facilities EPIC Women's Locker 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Family#2 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Family#3 1 1 Retrofit Wore w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Family#3 1 1 Retrofit Wore w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Man'. Locker 16 16 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Facilities EPIC Men's Locker 1 1 Retrofit Wore w/(2)F32T8/ADV841/EW/LL/ALTO 28WIamps&2L IOP-LP Facilities EPIC Men's Locker 1 0 No Retrofit at this time Facilities EPIC Men's Locker 3 3 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps & 21 IOP-LP Facilities EPIC Custodian 1 1 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Pool Storage 5 5 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Pool 30 30 1000W High Low System w/ ambient lighting control Facilities EPIC Pool 1 0 Sensor Spec AMBIENT SEfi 1 Facilities EPIC Pool 6 6 Install new Red LED Exit w/ Battery Back up Facilities EPIC Pool Observation 16 16 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP (Difficult Install) Facilities EPIC Lower Pool 56 56 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (1/2) 4L IOPLP (Difficult Ins Facilities EPIC Lower Pool/Hot tub 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP(Diffcult Install) Facilities EPIC Boiler Rm 1 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities EPIC Boiler Rm 1 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & (112) 4L IOP-LP Facilities EPIC Pool Mitch 11 11 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Ext Storage 4 4 Retrofit fixture w/(2)F32T8/ADV841/EWTUALTO 28W lamps &2L IOP-LP Facilities EPIC Ext Storage 2 2 Retrofit fixture w/(2)F32T8/ADV8411EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Upper Lobby 5 5 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-HP Bllst, & 2x2 kit Facilities EPIC Upper Lobby 4 4 Install new Red LED Exit w/ Battery Back up Facilities EPIC Upper Lobby Halls 14 14 Retrofit fixture w/ (2) F32T8/ADV841/EWTL/ALTO 28W lamps & 2L IOP-LP Facilities EPIC Emergency Stairs 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Emergency Stairs 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP (Emer Batt) Facilities EPIC Emergency Stairs 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Emergency Stairs 1 1 Retrofit fixture w/(2)F32T8/ADVMVEW/WALTO 28W lamps &2L IOP-LP Facilities EPIC Emergency Stairs 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities EPIC Emergency Stairs 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP (Emer Batt) Facilities EPIC Front Drive 4 0 No Retrofit at this time Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fixts Proposed Retrofit Description Sensor Type Facilities EPIC Wall packs -Lg 12 0 No Retrofit at this time Facilities EPIC Parking 37 0 No Retrofit at this time Facilities EPIC Wall packs -Sm 2 0 No Retrofit at this time Facilities EPIC Flag lights 3 3 Install new 26W CF Flood Fixture Facilities EPIC Main Lobby 1 0 Sensor Spec VEND MISER- Facilities EPIC Main Lobby 1 0 Sensor Spec VENDMISER- FacilitiesEPIC Concessions Lobby 1 0 Sensor Spec VEND MISER - Facilities Firing Range Firing Range 48 48 Install new4'1 L32 Asymetrical Wrap- Dimmable Ballast Facilities Firing Range Firing Range 8 8 Install new 4' 1L32T8 Asymehical Wrap (Dimmable -Tandem 2L) Facilities Firing Range Firing Range 16 16 Low Voltage Dimmer Facilities Firing Range Firing Range 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sand, & 2x4 Refl Facilities Firing Range Firing Range 6 6 Install new 26W CF Can (Dimmable) Facilities Firing Range Exercise Room 20 20 Retrofit fixture w/ (2) F32T8/AOV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 per Facilities Firing Range Men's RR 1 1 Install new 2' Vanity Fixture w/ (2) F17TS/TL841/ECO lamps- QHE LP Bllst Facilities Firing Range Men's RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities Firing Range Women's RR 2 2 Install new 2' Vanity Fixture w/ (2) F17T8/TL841/ECO lamps- QHE LP Blisl Facilities Firing Range Women's RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Firing Range Classroom 6 6 Retrofitfixture w/ (2) F32T8/ADV841/EW/LL/ALTO 28W (amps, 2L IOP Stntl, 2x4 Fort Facilities Firing Range Classroom 1 0 Sensor Spec CIR Facilities Firing Range Shop 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Stntl, 2x4 Roll Facilities Firing Range Shop 1 0 Sensor Spec WSIR Facilities Firing Range Armory 2 2 Retrofitfixture w/ (1) F32T8/ADV841/EW/LUALTO 28W Iamps & 1L IOP-LP Facilities Firing Range Armory Upstairs 1 1 Install New 2L 13W CF Drum Fixture Facilities Firing Range Mech Room 4 4 Install new 3L 13W CF Drum Facilities Firing Range Exenor 1 0 No Retrofit at this time Facilities Firing Range Exterior 2 0 No Retrofit at this time Facilities Firing Range Parking Floods 3 0 No Retrofit at this time Facilities Firing Range Bollards 4 4 Replace lamp w/ 18W Outdoor rated Screw in CF Facilities Firing Range Exercise Room Vending 1 0 Sensor Spec VEND MISER - Facilities Fleet Maintenance Lobby 101) 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Fleet Maintenance Lobby 100 1 0 No Retrofit at this time Facilities Fleet Maintenance Equipment Rm 100A 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Fleet Maintenance Office 1006 3 3 Install new e' 2128T8 Wrap- 2L IOP-Stnd Bllst Facilities Fleet Maintenance Women's RR 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Fleet Maintenance Women's RR 1 0 Sensor Spec WSUS Facilities Fleet Maintenance Men's RR 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Fleet Maintenance Men's RR 1 0 Sensor Spec WSUS Facilities Fleet Maintenance Custodian 1 1 Install New 21. 13W CF Drum Fixture Facilities Fleet Maintenance Corridor 100 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Fleet Maintenance Corridor 100 1 0 No Retrofit at this time Facilities Fleet Maintenance Mach Ran 2 2 Install New 13W CF Drum Fixture Facilities Fleet Maintenance Main Garage 32 32 Install new 8' 6LT8 Industrial fixture - IOP-HP Facilities Fleet Maintenance Main Garage 2 0 No Retrofit at this time Facilities Fleet Maintenance Main Garage 8 8 Retrofit fixture w/ (4) F32T8/ADV841/EW/LUALTO 28W lamps, 4L IOP-LP, & 8Industrial Ho Facilities Fleet Maintenance Compressor / Parts 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stnd, & 8' Industrial H Facilities Fleet Maintenance Oil Tanks 1 0 No Retrofit at this time Facilities Fleet Maintenance Metal Shop 4 4 Retrofit fixture w/ (4) F32TS/ADV841/EW/LUALTO 28W lamps, 4L IOP-LP, & 8' Industrial Ho Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fins Exist Fixts Proposed Retrofit Description Sensor Type Sensor Qty Fatalities Fleet Maintenance Metal Shop 1 1 Retrofit fixture w/ (4) F32TB/ADV841/EW/LUALTO 28W lamps, 4L ]OR LP, & 8' Hooded Ind C Facilities Fleet Maintenance Upper Storage 2 2 Install new 8' 6LT8 Industrial fixture- IOP-HP Facilities Fleet Maintenance Breakroom 110A 4 4 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP-Stud. & 8' Industrial H Facilities Fleet Maintenance Breakroom 110A 1 0 Sensor Spec CIR 1 Facilities Fleet Maintenance Office/Copy 2 2 Retrofit fixture w/(2)F32T8/ADV841/EWILUALTO 28W lamps, 2L OR SIntl, delamped Facilities Fleet Maintenance Office/Copy 1 0 Sensor Spec WSIR 1 Facilities Fleet Maintenance Parts once 2 2 Retrofit fixture w/(4)F32T8/ADV841/EW/LUALTO 28W lamps, 4LIOP-LP,&8'Induafm Ho Facilities Fleet Maintenance Partsoffice2 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L [OR Sind, delamped Facilities Fleet Maintenance Parts once 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L [OR Strip, delamped Facilities Fleet Maintenance Parts Storage 8 8 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP-Stud, & 8' Industrial H Facilities Fleet Maintenance Parts Storage 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP-Stnd.&V industrialH Facilities Fleet Maintenance Parts Storage 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Fleet Maintenance Storage 120A 1 0 No Retrofit at this time Facilities Fleet Maintenance Storage 221 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP-Stud, & 8' Industrial H Facilities Fleet Maintenance Storage 221 6 6 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOPStnd,&8'industualH Facilities Fleet Maintenance Storage 221 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALT0 28W lamps, 2L IOP-Stnd, & 8' Industrial H Facilities Fleet Maintenance Conference 6 6 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Strip, Small box Facilities Fleet Maintenance Kitchen 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L [OR End. &2x4 Refl Facilities Fleet Maintenance Conference 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Strip, &2x4 Refi Facilities Fleet Maintenance Conference 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP SIntl, 2x4 Ref Facilities Fleet Maintenance Conference 1 0 Sensor Spec CIR 1 Facilities Fleet Maintenance Hall 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Fleet Maintenance Hall 1 0 No Retrofit at this time Facilities Fleet Maintenance Men's RR 1 1 Retrofit fixture w/ (2) F32T8/ADVMVEW/LUALTO 28W lamps & 2L IOP-LP Facilities Fleet Maintenance Men's RR 1 0 Sensor Spec WSIR 1 Facilities Fleet Maintenance Women's RR 1 1 Retrofit fxturew/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Fleet Maintenance Women's RR 1 0 Sensor Spec WSIR 1 Facilities Fleet Maintenance Mach Rm 1 1 Install New 13W CF Drum Fixture Facilities Fleet Maintenance Cant Pm/Office 3 3 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Fleet Maintenance Office 2 2 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, delamped Facilities Fleet Maintenance Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L OR SIntl, Small box Facilities Fleet Maintenance Open Office 11 11 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W]amps, 2L IOP Strip, & 2x4 Refi Facilities Fleet Maintenance Open Office 1 0 No Retrofit at this time Facilities Fleet Maintenance Office 3 3 Retrofit fixture w/(2) F32T8/ADV841/EW/LUALTO 28W Iamps, 2L IOP Stnd, tlelamped Facilities Fleet Maintenance Office 1 0 Sensor Spec WSIR 1 Facilities Fleet Maintenance Once 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OR SNtl. Small box Facilities Fleet Maintenance Office 1 0 Sensor Spec WSIR 1 Facilities Fleet Maintenance Office 2 2 Retrofit fixture w/(2)F32T8/ADVM11EW/LUALTO 28W Iamps, 2L IOP Sind, delamped Facilities Fleet Maintenance Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L ]OR Sind, delamped Facilities Fleet Maintenance Stairs 1 1 Retrofit fixture w/(2)F32T8/ADV84VEW/LUALTO 28W lamps &2L IOP-LP (HighInstall) Facilities Fleet Maintenance Stairs 1 1 Retrofit fixture w/ (2) F32T8/ADV84IIEW/LUALTO 28W lamps & 2L IOP-LP Facilities Fleet Maintenance Stairs 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EWILUALTO 28W lamps & 2L IOP-LP (High Install) Facilities Fleet Maintenance Stairs 1 1 Retrofit fnure w/(2)F32T8/ADV841/EW/LUALTO 28W lamps &2L IOP-LP Facilities Fleet Maintenance Vestibie 1 1 Replace lamp w/13W Screw in CF Facilities Fleet Maintenance Exterior 10 0 No Retrofit at this time Facilities Fleet Maintenance Exterior 4 0 No Retrofit at this time Facilities Fleet Maintenance Exterior 8 0 No Retrofit at this time Attachment #1 - City-wide Lighting Scope Group Site Name Area Description Fixts Exist Fixts Proposed Retrofit Description Sensor Type Facilities Fleet Maintenance Exterior 3 0 No Retrofit at this time Facilities Fleet Maintenance Fuel Island 6 0 No Retrofit at this time Facilities Fleet Maintenance Vending 1 0 Sensor Spec VEND MISER - Facilities Fleet Maintenance Breakroom 110A 1 0 Sensor Spec VENDMISER- Facilities Lincoln Center Main Stage 8 0 No Retrofit at this time Facilities Lincoln Center Main Stage 1 0 No Retrofit at this time Facilities Lincoln Center Theatrical Lighting 36 0 No Retrofit at this time Facilities Lincoln Center Theatrical Lighting 34 0 No Retrofit at this time Facilities Lincoln Center Theatrical Lighting 12 0 No Retrofit at this time Facilities Lincoln Center Theatrical Lighting 12 0 No Retrofit at this time Facilities Lincoln Center Off Stage 9 9 Retrofit Wore w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Lincoln Center OH Stage 1 0 No Retrofit at this time Facilities Lincoln Center OR Stage Pulleys 17 0 No Retrofit at this time Facilities Lincoln Center Catwalks 5 5 Install new 3L 13W CF Drum Facilities Lincoln Center Catwalks 2 2 Retrofilfxture w/(2)F32T8/ADV841/EW/LL/ALTO 28Wlamps&2L IOP-LP Facilities Lincoln Center House lights 15 0 No Retrofit at this time Facilities Lincoln Center House lights 3 0 No Retrofit at this time Facilities Lincoln Center House lights 24 0 No Retrofit at this time Facilities Lincoln Center House lights 12 0 No Retrofit at this time Facilities Lincoln Center Maintenance Entry 8 8 Retrofilfixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (112) 4L IOP-LP Facilities Lincoln Center Maintenance Entry 1 1 Retrofilfixture wl (2) F32T81ADV841/EW/LL/A1_TO 28W lamps & 2L OP -LP Facilities Lincoln Center Stage Office 2 2 Retrofit fixture W (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Lincoln Center Mini -theatre stage 16 a No Retrofit at this time Facilities Lincoln Center Mini -theatre stage 2 0 No Retrofit at this time Facilities Lincoln Center Theatre Lights 60 0 No Retrofit at this time Facilities Lincoln Center Mini -theatre house lights 24 0 No Retrofit at this time Facilities Lincoln Center Mini -theatre house lights 2 0 No Retrofit at this time Facilities Lincoln Center Mini -theatre house lights 1 1 Replace lamp w/ 16W R30 Screw in CF Facilities Lincoln Center Mini -theatre house lights 12 a No Retrofit at this time Facilities Lincoln Center Mini -theatre catwalk 2 2 Replace lamp W 9W Screw in CF Facilities Lincoln Center Mini -theatre control booth 3 0 No Retrofit at this time Facilities Lincoln Center Hall 4 4 Retroftfixture w/ (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L IOP LP Facilities Lincoln Center Hall 1 0 No Retrofit at this time Facilities Lincoln Center Changing Rooms 4 4 Retrofitfixture wl (3) F32T8/ADV841/EW/LUALTO 28W lamps & 3L OP LP Facilities Lincoln Center Changing Rooms 1 1 Retrofitfixture wl (2) F32T8/ADV841/EW/LL/ALTO 28W lamps & 2L IOP-LP Facilities Lincoln Center Changing Rooms 4 4 Retrofilfixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Lincoln Center Changing Rooms 55 0 No Retrofit at this time Facilities Lincoln Center Mans RR 1 1 Retrofit fixture wl (2) F17T8/TL841/ALTO Lamps, 2L IOP-Stud Bllst, & 2x2 kit Facilities Lincoln Center Mans RR 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L OP -LP Facilities Lincoln Center Mans RR 1 1 Replace lamp w/ 13W Screw in CF Facilities Lincoln Center Mens RR 1 0 Sensor Spec WSUS Facilities Lincoln Center Womens RR 1 1 Install new 2' Vanity Fixture w/ (2) F17T8/TL841/ECO lamps- QHE LP Bllst Facilities Lincoln Center Womens RR 2 2 Retrofit fixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 3L OF LP Facilities Lincoln Center Womens RR 1 1 Replace lamp W 13W Screw in CF Facilities Lincoln Center Guest Artist Suite 3 3 Retrofit fixture w/ (2) F17T8/TL841/ALTO Lamps, 2L IOP-Sind Bllst, & 2x2 kit Facilities Lincoln Center Guest Artist Suite 24 0 No Retrofit at this time Facilities Lincoln Center Guest Artist Suite 1 1 Replace lamp w/ 18W Screw in CF Attachment #1 - City-wide Lighting Scope Group Ste Name Area Description FWs Exist Fixts Proposed Retrofit Description Sensor Typ[ Facilities Lincoln Center Guest Artist Suite 1 1 Replace lamp wl 13W Screw in CF Facilities Lincoln Center Custodian / DHW 1 1 Install new 2L 26W CF Drum Facilities Lincoln Center Janitor 1 1 Install new 2L 26W CF Drum Facilities Lincoln Center Hall 6 6 Retrofilfixture w/ (3) F32T8/ADV841/EW/LL/ALTO 28W lamps & 31 IOP LP Facilities Lincoln Center Entry Hall 3 3 Replace lamp w/ 16W R30 Screw in CF Facilities Lincoln Center Entry Hall 2 2 Replace lamp w/ 16W R30 Screw in CF Facilities Lincoln Center Entry Hall 20 20 Retrofit fixture w/ (1) F32T8/ADV841/EW/LUALTO 28W lamps & (1/4) 4L IOP-LP Facilities Lincoln Center Entry Hall 2 0 No Retrofit at this time Facilities Lincoln Center Entry Hall 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Lincoln Center Entry Hall 16 16 Retrofit fixture w/ (1) F32T8/ADV841fEW/LUAL7O 28W lamps & (1/4) 4L IOP-LP Facilities Lincoln Center Meeting Hall 80 80 Retrofit fixture w/(3)F32T8/ADV84VEW/WALTO 28W lamps, lL&2L OF LP (High) Facilities Lincoln Center Meeting Hall 21 21 Install new 42W CF Can (Dimmable with OS) Facilities Lincoln Center Meeting Hall 1 0 No Retrofit at this time Facilities Lincoln Center Meeting Hall 6 0 Sensor Spec CIR-HIGH Facilities Lincoln Center Meeting Hall 3 0 No Retrofit at this time Facilities Lincoln Center Storage 3 3 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Lincoln Center Storage 2 2 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W Iamps & (1/2) 4L IOP-LP Facilities Lincoln Center Storage 1 1 Install New 2L 13W CF Drum Fixture Facilities Lincoln Center Upstairs Storage 10 10 Retrofit fixture wl (2) F32T8/ADV841/EW/LUALTO 28W lamps, (1/2) 4L IOP Stnd, & lx8 Ref Facilities Lincoln Center Upstairs Storage i 1 Retrofit fixture w/(1)F32T8/ADV841/EW/LUALTO 28WIamps&11 IOP-LP Facilities Lincoln Center Upstairs Storage 6 6 Install new 4' 2L28T8 Strip - IOP-Sind Facilities Lincoln Center Kitchen 5 5 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & 2L IOP-LP Facilities Lincoln Center Kitchen 1 1 ReVofit Were w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Facilities Lincoln Center Kitchen 10 10 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps & (112) 4L IOP-LP Facilities Lincoln Center Dry Storage 1 1 Install new 2L 13W CF Drum Fixture Facilities Lincoln Center RR 2 2 remoe & rap Facilities Lincoln Center RR 1 1 Install new 4' 2128T8 Strip Fixture- OR Sind Facilities Lincoln Center RR 1 0 Sensor Spec WSIR Facilities Lincoln Center Meeting Hall 22 22 Retrofit fixture w/ (3) 1`32T8/ADV841/EW/LUALTO 28W lamps. I & 2L IOP LP (High) Facilities Lincoln Center Meeting Hall 9 9 Install new 42W CF Can (Dimmable with OS) Facilities Lincoln Center Meeting Hall 51 0 No Retrofit at this time Facilities Lincoln Center Meeting Hall 2 0 Sensor Spec CIR-HIGH Facilities Lincoln Center Scheduling Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps. 2L IOP Stnd, & 2x4 Hell Facilities Lincoln Center Scheduling Office 1 1 Retrofit fixture w/ (2) F32T8/ADV841/EW/LUALTO 28W lamps, 2L IOP Sind, 2x4 Refi Facilities Lincoln Center Scheduling Office 1 1 Retrofit fixture w/ (2) F32T6/ADV841/EW/LUALTO 28W Iamps, 2L IOP Slid, 2x4 ReFl Facilities Lincoln Center Cortidor 3 3 Replace lamp w/ 16W R30 Screw in CF Facilities Lincoln Center Cortidor 1 i Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps, 2L IOP Sind, delamped Facilities Lincoln Center Corridor 1 1 Retrofit fixture w/(2)F32T8/ADV841/EW/LUALTO 28WIamps&2L IOP-LP Facilities Lincoln Center Mans RR 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/LL/ALTO 28WIamps&2L IOP-LP Facilities Lincoln Center Mans RR 1 0 Sensor Spec CUS1000 Facilities Lincoln Center Womens RR 4 4 Retrofit fixture w/(2)F32T8/ADV841/EW/WALTO 28WIamps&2L IOP-LP Facilities Lincoln Center Womens RR 1 0 Sensor Spec CUS1000 Facilities Lincoln Center Ludlow Conference 6 6 Retrofit fixture wl (3) F32T8/ADV841/EW/LUALTO 28W lamps, I & 2L IOP LP Facilities Lincoln Center Ludlow Conference 20 20 Install new 26W CF Can (Dimmable & Grid Ceiling) Facilities Lincoln Center Ludlow Conference 1 0 No Retrofit at this time Facilities Lincoln Center Ludlow Conference 1 0 Sensor Spec CDT2000.11R Facilities Lincoln Center Ludlow Conference 1 0 No Retrofit at this time