Loading...
HomeMy WebLinkAbout102796 OLDCASTLE PRECAST - PURCHASE ORDER - 88526426z City of Fort Collins Page Number: 1 City of Fort Collins Date: 05/06/08 Purchase Order Number: 8852642 ueuvery uace: ubrubrua Buyer: DICK,OPAL Purchase Order number must appear on invoices, packing lists, labels, bills of lading, and all correspondence. Note: Line Qty/Units Description Extended Price 1 6990-8841 7,500.00 79x56x6" 3-phase xfiner pad YARD TRANSFORMER PAD, PRECAST, 79"X56" X6", FOR 3 PHASE, 75-500 KVA, FLAT TOP WITH NO RECESSED AREAS, PER SPEC, DWG 368-400, SERIAL #01, REV. AMCOR, 2 6990-8846 2,874.00 8473x6" 3-phase xfiner pad YARD TRANSFORMER PAD, PRECAST, 84"X73" X6", FOR 3 PHASE, 500-1000 KVA, FLAT TOP WITH NO RECESSED AREAS, PER SPEC. DWG 368-400, SERIAL #02, REV. AMCOR, Per quote dated 4/29/2008 (Wayne Bickford Delivery: Five weeks Total $10,374.00 This order is rlig0alid over $5000 unless signed by James B. O'Neill Il, CPPO City of Fort Collins Accounting Department City of Fort Collins Purchasing, PO Box 580, Fort Collins, CO 80522-0580 PO Box 580 Fort Collins, CO 80522-0580 6"-1' (73') 7,_0• <84') 52 PRIMARY SECt)N A/RY 16• 6' Space requirements for pad and primary switching cabinet will generally be 9'XI2'. Factors to be considered in locating the pad include — 1. ACCESSIBILITY — The transformer pad shall be accessible to the line boom trucks equipped for the installation and removal of heavy transformers. Typically, the pad must be placed within 10' of an all—weather surface where a line boom truck can be driven. Such accessibility shall not require intrusion on adjacent property. 2 PROXIMITY OF BUILDINGS, WALLS, AND/OR OVERHANGS — In addition to the clearances required for installation and removal, the minimum clearance in front of the transformer pad shall be 8' and the minimum clearance from all other sides shall be 3'. If the building has an overhang, clearance to the edge of the transformer pod shall be measured horizontally from the outer edge of the overhang. Transformers through 300 KVA may be installed under the overhang if the vertical clearance between the pad and the overhang is at least 25' and the location is accessible to line boom trucks. 3. CODES AND STANDARDS — In addition to the above, the installation shall conform to the National Electric Code and federal, state, and city codes and standards. NOTE — This pad is typically used for a service total between 2000 amps and 5000 amps at 120/208V 3—phase, or between 1200 amps and 2400 amps at 277/480V 3—phase. M. Moore 03 12/16/1996 City of Fort Collins Utilities Electric CITY OF FORT COLLINS UTILITIES Drawn By: I Rev # Date ( Stds. Mgr. Appr. Transformer Pad Design 500 - 1000 KVA 3 Phase r- I j_7__T__F__ I24 3/4"— 9 ,/4• L_1_J--)--1--t--1 ,6 � I I 13 1/2- T- 52- Tv #4 x 4'4' ® 12� C.C. (9 REO'D) y4 x 6'3' ® 12 C.C. (6 REO'D) /4- X 5 1/2- T-6A ANCHOR LIFTING INSERT (2 REQ'0) 2- GLASS REINFORCED INSERT(4 REO'D) 7 13 1/2• DESCRIPTION: 79' X 56" 6" PRECAST TRANSFORMER REFERENCE SPECIFICATIONS: PAD. TOP SHALL BE FLAT WITH NO RECESSED AREAS. ASTM A615 MATERIALS: TYPE III CEMENT ASTM C33 GRADE 60 REINFORCING STEEL WITH YIELD STRENGTH OF 60.000 psi ASTM C39 3/4- AGGREGATE, AIR -ENTRAINING AGENT. WATER -REDUCING AGENT. ACCELERATOR. SAND AND WATER CONCRETE SHALL HAVE 28 DAY COMPRESSIVE STRENGTH ASTM C136 OF 4.500 psi ASTM C143 DUALITY CONTROL ASTM C150 To assure proper quality contra and supervision, aonaete Pads shall be produced of a Notional Precast Concrete Assxiotion (NPCA) certified ASTM C192 manufacturing facility. The manufacturer shall comply with the requirements set by the NPCA's Quality Conlrai Manual far Precost Concrete Plants. ASTM C291 ASTM C260 ASTM C494 ACI MI-89 Specification far Deformed and Plain Billet -Steel Bars for Concrete Reinforcement Specifications for Concrete Aggregates Test Method for Compressive Strength of Cylindrical Concrete Specimens Method for Sieve Anclysis for Fine and Coarse Aggregates Test Method for Slump of Portland Cement Concrete Specificotions far Portland Cement Method of Making and Curing Concrete Test Specimens o the Laboratory Test Method of Air Content of Freshly Mixed Concrete by the Pressure Method Specfcaton for Air Entrainment Admixtures of Concrete Specification for Chemical Admixtures for Concrete Specification for Design of Concert using Ultimata Strength Methods OITV OF FORT OOLLINIII LIGHT and POWER PRECAST TRANSFORMER PAD for 75 — 500 KVA Specification R 368-400, serial 01 ROL ENG X'PoBY SCALE T. SAGEN G_10 NONE 1. BY DATE SVEET S. CORAM 10/25/95 1 1 a 1