CHANGE ORDER NO, 03
PROJECT TITLE: CSU TRANSIT CENTER
CONTRACTOR: MARK YOUNG CONSTRUCTION
PROJECT NUMBER- 5W9
DESCRIPTION: CHANGES TO THE CONTRACTOR'S AGREEMENT
In preparing Change or+dem show In order as separate numbered paragraphs the %Mowing:
1. Reason for change: Unknown electrical pipe location.
2. Descrlpdon of change: COR No. 8 See Attachments
3. Change in contract cost $3,941.00
4. Change in contract time:
(Attach additional sheets as M-g gjmjb
ORIGINAL CONTRACT COST.........................................................................$4,318,404.00
TOTAL APPROVED CHANGE ORDERS ....................................................................3868A0
TOTAL PENDING CHANGE ORDERS..............................................................I...........00.00
TOTAL THIS CHANGE ORDER .............................. ........................................ ......32�,
ADJUBM CONTRACT COST............................................................
. ..................... .. .. ...................4, 23.
TOTAL % THIS CHANGE ORDER ......................... Less than 1%
TOTAL C.O. % OF ORIGINAL CONTRACT....................Len than 1%
ADJUSTED CONTRACT COST ... .................... .................
................i4,830,�18.00
REVIEWED BY:
e-
ACCEPTED BY;
ACCEPTED BY:.
ACCEPTED BY:
CIT Y, BTM WHITE, PROJECT MANAGER
j
APPROVED BY:
APPROVED BY:
PURCHASING AGENT OVER MDO
O
DATE
DATE
1 3,0 -45;.
DATE
DATE
DATE
ca Project File, Contractor, Purchasing, Engineer
JAN-04-2008 WED 09125 AM WAYNES ELECTRIC INC FAX NO. 3036540877
P, 05
CSMS 271
Jon 04, 2M 08..W M
Page: 3
F7ro1 Pricing
Value (51..
92t.t3
(%)
Atom
Code
LaborTogl —^
Total C
OM
D�Mbaae Material 6V6i ad
31e 2rS
Labor Overhead
Total Overhead
139.71
t 0 boa
t?audwe Material Markup
Labor Markup
G2.11
t6.aaa
TotaiMarko
Salting Prioe
231.12
10.=
2,550.0a
.
Fkla1 Price
2,650.0E
.1.�
Jan. 4. 2006 12:43PM c00rer-clack
Dio 12 2005 315OPM MARK YOUHG CONSTRUCTION
t.�:•
y+•
� a
RR*
16 DATE
TO:
COovar-dark & Aasodatss, P.c PR6jwrN:
4511 Shamran WoK GU% 205 PROJECT:
Denve r, CO ti0m
AT7EWM.
Jay Lamtoq,
Plsaas advlis a pan of acffon
On Its IIYrH tto0r. Panel NO Is fed ftm gow SOC.4.
The rieepom b RFkRB no lading 11Ns saRts p e aovLp Idsd In
IMPACT. DATE RE8PON9E REQUMSM t3Y:
ndu. DEUY SMEDut.i: W CMCVjM.
POTENTIAL COST IMPACT IP CHRom
-
`-- • . on lIt
No, H94 P. 2
197O4023O81 P • goo
City Of Ft. Caine 3 CSU Tmnd camel I
the unknown pipe In 1Me ►"tr level
IPW UW 2-1)2' or 3" Wm fords man
1?1f912006
crrinarmrrrlo.•`_`
Max Millen
From: Jay Lamicq Daylamicq@coover-clark.com]
Sent: Thursday, December 22, 2005 3:29 PM
To: Dennis Wolfe; Max Millen
Cc: Edward Balkin
Subject: FW,. CSU Transit Center- Response to RFI #16
Attachments: RFI #16 sketch. pdf
17
RFI *16 sla t. .pdf
(99 KB)
Max -
Below is our response from our electrical engineer in regards to the electrical conduit in
the women's bathroom. I wanted to send these options to you to pass along to Wayne's
Electric for their input before answering this RFI officially. Here are my comments for
these options:
Option #1: This option is not possible by code.
Option #2: This option is too expensive (Approx. $20,000) to add new copper line to the
panel.
Option #3: This is a viable option but this will use up most of the panel.
Option #4: I would prefer this option above all. We would have to splice the line and cut
the slab to get this to work, but I think it is the best solution as far as costs go. Our
Electrical Engineer is concerned about cutting the steel pipe to expose the line as well
as the time required to splice while power is down. I have attached a sketch describing my
intentions. We can provide j-boxes in the wall and also above the ceiling for the splices.
Please let me know if option #4 can be done, and call with any questions.
Jay R. Lamicq, Assoc. AIA
Associate Designer
Coover-Clark & Associates
455 Sherman Street, Suite #205
Denver, Colorado 80203
(303) 783-0040 ext. 16
(303) 783-0060 fax
Email: jaylamicq@coover-clark.com <mai.lto:jaylamicq@coover-clark.com>
Web: www.coover-clark.com <http://www.coover-clark.com/>
"The sender believes that this E-mail and any attachments were free of any virus, worm,
Trojan horse, and/or malicious code when sent. This message and its attachments could have
been infected during transmission. By reading the message and opening any attachments, the
recipient accepts full responsibility for taking protective and remedial action about
viruses and other defects. The sender's employer is not liable for any loss or damage
arising in any way from this message or,its attachments."
1
-----Original Message -----
From: Curtis McMillin [mailto:cmcmillin@bcer.com)
Sent: Wednesday, December 21, 2005 2:00 PM
To: Jay Lamicq
Cc: Matt Killebrew
Subject: CSU Transit Center
Jay,
Matt and I visited the job site this morning. Attached is Electrical Field Observation
Report #1.
Regarding the existing electrical feeder that rises vertically through WOMENS RR 050 to
existing Panel "NM":
Option 1) Remove one toilet and move the handicapped stall north, this could save cost,
and the electrical feeder riser can remain in its present location. Or, Option 2) Remove
feeder conductors and abandon existing conduit below slab. Remove feeder riser in
handicapped stall. Provide new 100 Ampere feeder, to replace existing, to Panel "NM" from
existing 100A/3P switch/fuse unit in Sub -Distribution Switchboard "SDC-5", (4#2 & It
8G)1-1/2"C. This new feeder may be routed beside the new feeder to new Panel "NFl/NF2".
This method is preferred to Options 3 and 4.
Or,
Option 3) Remove feeder conductors and abandon existing conduit below slab. Remove feeder
riser in handicapped stall. Provide new 100 Ampere feeder, to replace existing, to Panel
"NM" from new 100A/3P circuit breaker in New Panel "L1A", (4#2 $ 1#8G)1-1/2"C. This
method is not recommended as it will use most of the spare capacity presently designed in
the New 400A Panel "L1A" and motor inrush voltage drop issues may be an issue. Or, Option
4) Remove feeder conductors and replace with new feeder conductors in existing conduit
below slab. Cut and patch concrete floor to reroute feeder around handicapped stall to
existing Panel "NM". This method is not preferred as it appears more costly than above
options and a lengthy power outage to existing panel "NM" would be necessary.
Let me know if you have any questions or desire more information to price or select one of
the options above.
Thanks,
Curt
No virus found in this incoming message.
Checked by AVG Free Edition.
Version: 7.1.371 / Virus Database: 267.14.2/208 - Release Date: 12/20/2005
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.1.371 / Virus Database: 267.14.3/209 - Release Date: 12/21/2005
2
Rv,ocwr c-v>
j° COAPO K
vi mir, 9,e°vy
I
I
Q
ii
Arch twu Plmmera I.mrdreapes Intariora
ARCHITECT'S
SUPPLEMENTAL INSTRUCTIONS
(ASI) #8
455 Shaman StreeL Suite 205 Denver, Co 80203
Phone: 303-753.0040 Far. 303.783-W50
webmai1ft=over-dwk.eom
OWNER
[ X)
ARCHITECT
[ X)
CONSULTANT
[ I
CONTRACTOR
IX)
FIELD
[ l
OTHER
[ )
PROJECT: CSU & Fort Collins Transit Center ARCHITECTS SUPPLEMENTAL
Colorado State University INSTRUCTION NO 8
DATE OF ISSUANCE; 11130/2005
OWNER: Fort Collins & CSU
TO: Mark Young Construction
(contractor) 4150 Jason Street
Denver, CO 80211
CONTRACT FOR: Transit Center
CONTRACT DATED:
ARCHITECT Coover-Clark & Associates, P C
455 Sherman Street, Ste 205
Denver, CO 80203
ARCHITECTS PROJECT NO 0320
The Work shall be carried out in accordance with the following supplemental instructions issued in accordance
with the Contract Documents without change in Contract Sum or Contract Time. Proceeding with the Work in
accordance with these instructions indicates your acknowledgement that there will be no change in the
Contract Sum or Contract Time.
Description
1. New C-store electrical lighting layout, per SK-6 & fixture cut sheet attached, with prismatic lens
2. Trace origin of unknown pipe at women's RR #50 Cut at ceilin and slope to chase connect tc
3. Install new EWC as bid, move to location opposite new Lavatory at men's #47 Tie plumbing in under
counter, furr out below counter as required, with gyp. board and metals studs, paint wall, provide CT base
to a 6" ht. DO NOT violate ADA clearance.
4. Tie plumbing into "Gridline E" from Breakroom #73, to be covered with cabinets Keep tie-ins below
counter.
5. Delete intumescent paint @ pipe columns and change all pipe columns to a 4" nominal XXS with 3 hr
wet mix spray applied fire resistive material & provide wrap, see SK-7 and SK-8
Contractor to provide credit for new design.
6. Change UL rating for barrel roof to meet UL design # P502, see SK-9
Contractor to provide credit for new design.
7_ Change slope of (e) conf room 228 ceiling in lieu of flat patch, re -size windows and louver, see SK-10
ASI#8.xls Page 1
Contractor to provide credit for new design.
8. No cost change (a) stained conc. to Pantheon 13"x13 tile, Palo Series 90-105. Lay pattern
45 degree angle to grid w/ 1116" grout. Art pattern to be water jet cut into tile, same colors.
Install per mfg. recommendations.
9. Contractor to proceed with external stairs as designed, although MYC may elect to contract
SA Miro for re -design services if needed.
10. Additional blinds, beyond those bid at (e) conf. Room 228 are inside and not sun control issues
Owner to provide if needed.
Attachments:
SK-6 to 10
ISSUED BY: Jay Lamicq, Associate
ASI#8.xls Page 2
Via Facsimile 303-783-0060
January 5, 2006
Coover-Clark & Associates
455 Sherman Street, Suite 205
Denver, CO 80203
Project Title: City of Fort Collins & Colorado State University Transit Center Phase 11
Project No. 05477
Subject: Unknown Electrical Pipe in Restroom #50
RE: Change Order Request Number. COR No: 8
Gentlemen:
Pursuant to the above subject matter, please find enclosed our cost summary, qualifications, and back-up to move
the unknown electrical pipe located where the new south wall of Restroom #50 will be located. Pricing is
contingent upon the response to RFI#16 issued 12/12/06 to Coover-Clark & Associates. The total cost to perform
the above referenced work is $3,941.00.
Please note the following during review of this change order request:
1. RFI#16 Response per CCA: Originally it was requested by Coover-Clark and Associates that MYC
provide pricing for option #4 as stated in RFI#16. The work to be performed entails cutting the pipe at
floor and ceiling levels, saw -cutting the floor slab, moving the electric lines and piping into the stud wall
of room 49. Pricing and backup is attached per the meeting with Wayne's Electric, CCA and MYC on
Friday, 116/06 and CCA's final response to RFI#16 dated 1/4/06.
If you should have any questions and/or concerns, please contact me at your earliest convenience at
(303) M-1421
Sincerely,
Max Millen
Project Engineer
cc:
05477-F-1.2
Steve White 970-221-6534
Cass Beitler 970-491-7572
Owner response, please sign as appropriate:
Approved, Proceed as Submitted
Rejected, Do Not Proceed, Provide Comments
Other, Do Not Proceed, Provide Comments
MARK YOUNG CONSTRUCTION, INC.
PROJECT NAME: City of Fort Collins and CSU Transit Center Phase II
PROJECT NUMBER: #06477
CHANGE ORDER REQUEST SUMMARY
COST. CODES
ACTIVITY DESCRIPTION
AMOUNT
TOTALS
CHANGE ORDER REQUEST#8
ASI#8.2
MARK YOUNG CONSTRUCTION LABOR: $201hr
Remove Sawcut Concrete - (4MH's @ $30.69)
$123
FRP New 6" Slab - (8MH's @30.69)
$246
MYC LABOR TOTAL
$368
$368
MYC MATERIAL
Concrete to Replace Existing Slab - (1 CY)
$84
MYC MATERIAL TOTAL
$84
$84
MYC EQUIP.
Sawcut Existing 6" Slab - (151-17)
$400
MYC EQUIPMENT TOTAL
$400
$400
SUBTOTAL
$852
SMALL TOOLS & SUPPLIES @ 5% OF LABOR
$18
PAYROLL TAXES & INSURANCE @ 38% OF LABOR
$140
GENERAL CLEANUP: N/A
$0
DELIVERY: N/A
$0
DRAWINGS & SPECS: BY ARCHITECT
$0
SUBTOTAL
$1,010
MYC OVERHEAD & FEE @ 15.0%
$152
SUBTOTAL MYC WORK
$1,162
l
MARK YOUNG CONSTRUCTION, INC.
PROJECT NAME: City of Fort Collins and CSU Transit Center Phase II
PROJECT NUMBER: #05477
CHANGE ORDER REQUEST SUMMARY
COST CODES
ACTIVITY DESCRIPTION
AMOUNT
TOTALS
SUBCONTRACTS
ASI#8.2 Pricing- Unknown Pine 0 RR#50
Wayne's Electric
Move Panel Feed for Panel NQ from the Women's RR#50
$2,550
- Per RFI#16 Relocate 3" Conduit in New Wall
- Provide J-Boxes in New Wall w/ Access from RM. 49
SUBCONTRACT TOTAL
$2,550
$2,550
SUBTOTAL
$2,550
MYC FEE @ 5.0%
$128
SUBTOTAL SUBCONTRACTOR WORK
$2,678
SUBTOTAL (DIRECT COSTS)
$3,840
BUILDERS RISK INSURANCE @ 1.0%
$38
LIABILITY INSURANCE @ 0.75%
$29
MYC BOND:.86 %
$34
SUBCONTRACTOR BOND: N/A
$0
PERMIT FEES: NIA
SALES TAX: N/A
CONTRACTOR CONTINGENCY @ 0%
$0
$0
$0
PROPOSED CHANGE TOTAL
$3,941
JAN-04-2008 WED 09,24 AM WAYNES ELECTRIC INC FAX NO, 303654OB77
P. 01
Niaps'i eeetrk Mt.
WEI
WAYNE*S ELECDUC, INC. .
130 S. MAIN ST. BRIGHTON'CO $0601
DATE:
NrMBER OF PAGES: , S
M4C>;,UDM COVER)
TO: FROM:
/I Alan White
Proiect Manager
CELL # 303419-7885
PHONE 303-659-7481
FAX 303-659-0877
COMMENTS:
130 South Main Street 8dghtoa, Colotado $0601. 30"9-7461 • Fax 303-6S4-087y� L
' 1
AN-04-2006 WED 09124 Ail WAYNES ELECTRIC INC FAX N0, 3036540877
CHANGE ORDER
WAYNE'S ELECTRIC INC.
130 SOUTH MAIN STREET
BRIGHTON COLO. WWI
PHONE: 639-7461
FAX:654.0877
CHANGE TO: MYC
ATTENTION: MAX
JOB LOCATION: CSU TRANI
..max. ./i /II.M nLnY/'SC NNCD WIVY��•
WE HEREBY AGREE TO MARE THE CHANGE(S) EPECtFIED BELOW
IRFI#16
Move panel feed for panel NO from the new Woman restroom to new storage room
a
NOTE: THIS CHANGE ORDER BECOMES PART OF AND IN CONFORMANCE WITH THE CONTRACT:
WE AGREE TO MARE THE CHANGES) SPECIFIED ABOVE AT THIS PRICE: SZ560.00
DATE: .lame 4_2006
AUTHORIZED SIGNATURE(CONTRACTOR):..-
ACCEPTED:
DATE OF ACCEPTANCE:
SIGNATURE OWNER :
P. 02
JAN-04-2006 WED 09:24 AM WAYNES ELECTRIC INC FAX NO. 3036540877 P. 03
0SU16 271 Jan 04, 200(1 09..% M
Page:1
Job Name: CSU16
Job Nwabar. 271
Job Path: C1Pmwam FllealAenbid DSWJobdata1271.ES6
Job Typo'
Rw Due Data: 011042006 01110AM
ex"w Nor:
Telephone:
fan: .
Emaw.
Jab aearesa:
Nut *=: RR#16
CSU TRANSFER
FT COLLINS. CO
Client addraes:
1
04aoripbon
Qty
Doh
price
U
Disc IMat.
Adj.
Nat PdoO
Labor
U
Total MOO)
r
2 EMTCONDUIT
t062212005
10
64=2005
�412.11C
760.69le
0.00
0.00
0.00
0-001
0.0D
0.00
412.11
766.62
1,327.29
11.40C
16.600
27.00
42.00
41.21
2
_ _
130 EMT CONDUIT
2" EMT STL SS CONN
76.63
3
2
1/192005
1,327.20
C
C
26.55
4
3" EMT STL SS CONN
4
11191200 ,
S,153.14
0.00
0.00
0.09
5,153./4
_206.13
39.99
- 72,49
0.19
109.03
_ 62.53
69.93
3 Al
1.31
5
3" EMT STL 08 CPLG
1
1/1812d05
3,999.07
0.00
3,999.07
0.00
C_
6
3" EMT 90 DEG ELBOW
_
1
11/0/2005
7.249.080
0.00
0.00
0100
0.00
7,249.08
90.00
C
7
3" EMT STRUT CLAMP
2
1
2
12/15/2004
459.50
459.50
19.05
c
6
3" GRC 140-THREAD CONN
9I262005
10,993.00
0•DO
0.00
_
0.00
10,993.00
49.50
C
9
i0
11
12
3" GRC COUPLING_
1IMM005
9/262005
3,141.72
C
� 0.00
3,141.72
099.25
0.00
15.90
C
C
3" PVC r
10
09926
C
0.00
0 00
3" PVC TERM ADAPTER
1
1
21112312005
322005
3220o5
390.51
C
0.00
390.61
42.00
42.00
0.00
120,00
13.36
_ 28.35
156.1_5
C
C
3" PVC FEM ADAPTER
_
430.74
365.1110
C
0.00
_0.00
0.00
A30,74
365.11
1,421.00
7,011.89
13
3" PVC COUPLING
C
M
0.00
0.o0
0.0o
0.00
0.00
0.00
C
C
M
M
M
7,30
14
3" PVC 90 DEG ELBOW
1
11/23ft005
_
' 1,.t21A0
14.21
15
06 TMN
1S
_ 45
40
11/30=5
1,011.89
- _ 15.16
18
0310 THHN
1113o/2005
5,599.93
M
_
0.00
0100
5,599.93
252.00
17
_
SER 1/0.1_JO 110-2 (CU)
12/52001
^_ 0_.00
M
0100
0.00
0.00
0.00
18
0250MOM MECH LUG
� �- 2
12292004
2116/2006
7/20/2005
7/14/2004
V 337.15
21085.Oo
116.5
C
C
E
0,00
0.00
O.OD
0.00
0.00
337.15
2,005.00
25.50
-- 56.660
C
6.74
19
AYP250 250 AL CABLE
4
_
$3.40
233.38
48.39
20
21
22
24)a4x 6" SCREW CVR SOX NEW
-2
0.00
115.69
483.90
- 12120
Z.70
16sO
E
C
P-100D 1 5/8" STRUT
10
483.90
C
0.00
D.OD
0.00
3111' PLATED T-ROD
101211512004
16
8wo05
121.20
C
0.00
4.50
3,00
C
C
12.12
1,30
23
24
3/8-16 HEX NUT (PLATED]
318" (ENDER WASHER
totals
_
0.15
0.00
C
0.00110.00
_ &IS
16
12/5/2001
C
O.OD
0.00
/
Q*
Total H_ oure
Lab. Cond.
Normal
Prix Code
980D1o02006
98001002008
Oesoript on _ - _
2" EMT CONDUIT
Mat. Cond.
Normal
Manufao4xer Name_
Catalog Number
10
10
2
_ 1.14
1.50
0,54
CONDUIT RIGIO-EMT
T
3" EMT CONOUR
Normal
_ Normal
Normal
Normal
CONDUIT RIGID -EMT
CONDUIT 8 CBL FTG_
3
2"� EMT STL SS CONK ..
_
9Boo7o135D6
4
3" EMT $TL SS CONN
_ 4
1.68
Normal
Normal
CONDUIT 8 CBL F_T
08007013508
5
6
7
3" EMT STL 6S CPLG
1
0.00
0.00
Normal
No Labor
CONDUIT 3 CBL PTG
98007013we
96002002028
3" BUT 00 DEG ELBOW
"
1
Normal
Normal
Normal
Nomrat
CONDUIT FIGS RIGIDI
3" EMT STRUT CLAMP
_
3" GRC-AO- BEAD CONN
2
0.38
_ .
0.50
B-LINE SYSTEMS
B10_62-3
78101157t445
8
_ 1
2
_ _ 10
Normal
Normal
_
CONDUIT 6 CBL FT
- _
0007012528
98002000135
8
3" GRC COUPLING
0.00
1.69
OA2
Normal
No Labor
CONDUIT FIGS RIGID
_
10
3" PVC
Normal
Normal
Normal _
Normal
CONDUIT S FTGS _W
CONDUIT 6 FTGS
_ _ _ _
J
980060060011
11
12
3" PVC TERM ADAPTER
1
1
8800800820e
3' PVC FEM ADAPTER_
0.42
Normal
Normal
CONDUIT d PTGS FIV4
98008006216_
13
3" PVC COUPLING r
2
0.00
Normal
No Labor
CONDUIT », FTGS PV
_
98006006t06
14
3" PVC 90 DEG ELBOW
1
1.20
Normal
Normal
CONDUIT 8, r;
98008006p48
AN-04-2006 WED 09;24 AM WAYNES ELECTRIC INC FAX NO, 3036640877 P, 04
CSU16 2T1
Jan 04, 2008 (WOSAM
Pop$:2
DaaotWW Qty TOW Hours Mat Card. Lob. Goad. Muw% tuner Name Caalop Number Pace Codo
15 T14W 15 0,20 Narmel Normal COPPER WIRE THHN•648UG195 9801OM3160
18 SMTHHN 45 1.28 Normal Normal COPPER WIRE MN-3/043LK-19S 980100 U10
17 SER 1/0.1/0-1/0.2 (CU) _�— 40 6.25 Normal Normal - .�-
18 Fn� MECH LUG — 2 0.51 Norma9 N_amal ILSCO TA-266 78368986i42
2.35 Normal Normal _ ..,.
5.401 Normal l Normal
1A5 Normal Normal
Z, j3WIG HEX NUT (PLATED) 16 0.4d Normal Normal ISCRE
24 34- FENDER WASHER ll 024 Normal Normal
Tolah — . , — _
SYSTEMS ATR38X120~.. .
VSNUTS-BOLT . _
Labor Type
Full Rate
Cone
Type
1
FOREMAN
31130
_2
JOURNEYMAN
33,70
3 _
APPRENTICE
22.60
—
Totais_ M
31.6p
Rnal Pd ' Value (3) Pa Ste)..- Alarm Code
Oelabate MaWW (E)derulon) 1.397.13
MatKiel Taal
Direct Labor 921.13 --