HomeMy WebLinkAbout256604 SOUTHWEST FIBERGLASS INC - PURCHASE ORDER - 6605954Date: 09/18106
City of Fort Collins
Page Number: 1
City of Fort Collins
Purchase Order Number: 6605954
Delivery Date: 11/24/06 Buyer: DICK,OPAL
Purchase Order number must appear on invoices, packing lists, labels, bills of lading, and all correspondence.
Note:
Line
Qty
UOM Description
Unit Price
Extended Price
1
75
EA 6550-8640
1,029.000
77,175.00
complete smalll oval vault
YARD
VAULT, COMPLETE, SMALL OVAL PRIMARY, 3' X 6' WITH QUEEN OLIVE
COLOR COVER, UNASSEMBLED, WITHOUT ASSEMBLING HARDWARE, WITH'
LOCKING HARDWARE INSTALLED,
PER SPEC. #366-103
SOUTHWEST FIBERGLASS,
2 LS Plant Materials & Supply .000 3,200.00
Estimated Freight
DELIVERY: 10-12 WEEKS
Total $80,375.00
City of Fort CtAlljs Director of Purchasing and Risk Management City of Fort Collins
This order is valid over $2000 unless signed by James B. O'Neill II, CPPO, FNIGP Accounting Department
City of Fort Collins Purchasing, PO Box 580, Fort Collins, CO 80522-0580 PO Box 580
Fort Collins, CO 80522-0580
THE CITY OF FORT COLLINS
Light and Power Department
P.O. Box 580
Fort Collins, CO 80521
SPECIFICATION NO: 366-103
Fiberglass Utility Vault
,n
APPROVED BY:jr
Kraigo6ader
Standards Engineering Manager
PREPARED BY: Kraig Bader
Date: September 22, 1992
Revision Date: February 4, 2005
REV: C
REV. SYM C
REVISION DESCRIPTIONS
DESCRIPTION (previous revision descriptions on file)
CHANGE
APPROVED
NOTICE
Revision A:
N/A
Sagen/Coram
Paragraph 3.4. — deleted requirement for "queen olive gel coat" on all
9/28/92
vault parts
Revision B
Paragraph 2.1 — Edited the testing paragraph to clarify the test
N/A
methods and results desired for the vault lid. This is a clarification of
10/4/2002
the intended test method only and no test values were changed.
Revision C
Kraig Bader
• Paragraph 2.1 — Specified that load rating shall be an ultimate
2/1712005
load rating. Amend load rating from 14,100 pounds -force to
10,000 pounds -force. The reduced load rating is selected as
a compromise between strength rating and lid weights that
will allow safe operation. (Line Crew Foreman lifting limit from
floor to knuckle is 52 pounds.)
• Paragraph 3.3 - Cover weights for oval vaults changed from
minimum of 58 pounds to a range between 60 and 80
pounds.
• Paragraph 4 - Modified "Qualification Testing" requirements
to include more specific language that requires testing for any
design or process changes on both the covers and the vaults.
M-41-M R
REV. SYM C
TABLE OF CONTENTS
REVISIONDESCRIPTIONS....................................................................................................................................2
TABLEOF CONTENTS............................................................................................................................................3
1 GENERAL DESCRIPTION....................................................................................................................................4
2 PERFORMANCE REQUIREMENTS...................................................................................................................4
3 CONSTRUCTION REQUIREMENTS..................................................................................................................4
4 QUALIFICATION TESTING................................................................................................................................4
366-103
SPECIFICATION FOR
FIBERGLASS UTILITY VAULT
1 GENERAL DESCRIPTION
REV. SYM C
This specification covers large fiberglass utility vaults for sub -surface installation of electric equipment.
Vaults purchased under this Specification shall be in accordance with drawing no. 366-103 and the
following requirements.
2 PERFORMANCE REQUIREMENTS
2.1 Covers shall support a minimum ultimate load of 10,000 pounds -force when tested with a point load
applied to a 12" diameter steel plate placed at the center of the lid. Covers shall be tested with the
lids in place on the vault housing.
2.2 Sidewalls shall have a minimum ultimate strength of 3,000 pounds -force when tested with a point
load applied to a 10" x 10" plate placed in the middle of the sidewall.
2.3 The structural properties of the vault shall remain stable over a temperature range of -50OF to +200°F
3 CONSTRUCTION REQUIREMENTS
3.1 The vault and cover shall be constructed of fiberglass reinforced polyester (FPR) with a minimum of
30% glass, the balance being isophthalic polyester resin. The resin shall include ultraviolet
inhibitors.
3.2 The side panels and half round end sections shall be a minimum of 210 mils thick. Side panels shall
be a minimum weight of 36 lbs. each. End panels shall be a minimum weight of 46 lbs. each.
3.3 The cover shall be constructed with reinforcing ribs as shown on drawing 366-103. The top of the
cover shall be a minimum of 474 mils thick, shall have a non-skid surface, and shall be impregnated
with a queen olive color.
3.3.1 Round covers shall have a minimum weight of 30 pounds.
3.3.2 Oval covers shall have a weight between 60 pounds and 80 pounds.
3.4 Deleted
3.5 Dimensional integrity shall be such that parts can be randomly selected for development of either an
oval or round vault.
3.6 All hardware shall be stainless steel.
4 QUALIFICATION TESTING
Manufacturers shall be required to provide certified test reports prior to placing an order and on at least
one vault and cover from the first production run following any design or process change. Test reports
shall verify that the glass content and ultimate strength of the covers and the vault sections
manufactured under the manufacturer's process conform to this specification.
366-103