Loading...
HomeMy WebLinkAbout102795 WESCO DISTRIBUTION INC - PURCHASE ORDER - 6604953Date: 08/04/06 City of Fort Collins Page Number: 1 City of Fort Collins Purchase Order Number: 6604953 Delivery Date: 03/16/07 Buyer: DICK,OPAL Purchase Order number must appear on invoices, packing lists, labels, bills of lading, and all correspondence. Note: Line Qty UOM Description Unit Price Extended Price 1 10 EA T3000051; XMFMR 500 kVA; 480Y/277 T3000051 YARD TRANSFORMER, 500 kVA PAD -MOUNTED COMPARTMENTAL TYPE, THREE PHASE DISTRIBUTION WITH SEPARABLE INSULATED LOAD BREAK HIGH VOLTAGE CONNECTORS. HIGH VOLTAGE RATING: 13200 GRDY/7620. LOW VOLTAGE RATING: 480Y/277. SERIAL NUMBER 051 TO BE IN ACCORDANCE WITH SPECIFICATION #368-300-051, REVISION MM MFR. ABB ESCALATION IS APPLICABLE ADJUSTMENTS WILL BE REVIEWED BY CITY PRIOR TO PRODUCTION AND IN 13, 376.000 133, 760.00 Opal Dick_ 368dash300.pdf Page REV. SYM: MM 3.2 SPECIFIC REQUIREMENTS FOR DESIGN OF LOOP -FEED Units 3.2.1 FUNCTIONAL DESCRIPTION The transformer shall be a three phase, pad mounted, loop feed -safe break, "deadfront" type for use on a 13.8 kV grounded "Y" distribution system. 3.2.2 DESIGN AND CONSTRUCTION 3.2.2.1 RATINGS Table 1 - L000-Feed Transformer Ratinas Stock No. WA Low Nominal Voltage Impedance Bushing T. a/Confi . High Voltage Low Voltage 368-300- 008 75 20BY/120 1.9% c of 368-300- 009 75 4BOY/277 1.7% c of 368-300- 015 150 208Y/120 2.1% c of 368-300- 016 150 480Y/277 2.1% c of 368- 300 20BY/120 25% c of 36-300-01 3 300 480Y/277 2.5% c of 368-300- 050 500 208Y/120 3.04% c e 368-300- 061 500 480Y1277 3.04% c of 368-300- 075 750 208Y/120 5.75% c ci 368-300- 076 750 480Y/277 5.75% c 368-300- 100 1 1000 208Y/120 5.75% c 368-300- 101 1 1000 1 480YI277 5.75% c 368-300- 151 1500 480Y/277 5.75% c 368-300- 201 2000 480Y/277 5.75% c 368-300- 251 2500 480Y/277 5.75% c cFigure 1 (V-config.) of this specification e Low -voltage line and neutral terminals shall be stud type bushings in accordance with ANSI C57.12.26-1992, Fig. 9(d) and shall include a separate spade with NEMA standard drilling f Figure 9(a) of ANSI C57.12.26 -1992 (4hole pad) g Figure 9(b) of ANSI C57.12.26 -1992 (6-hole pad) (<b�aF�Yq�Si[iL1fi4Ti� 3.2.2.2.1 The basic impulse level (BIL) of the comple lely assembled transformer, including high -voltage and low -voltage terminals shall be 95 kV and 30 kV respectively. 3.2.2.2.2 Dielectric test levels shall be in accordance with the distribution levels in Paragraph 5.10 of ANSI C75.12.002000 3.2.2.2.3 The unit shall withstand test voltages in accordance with ANSI C57.12.00 and impulse tests in accordance with NEMA Standards for Transformers, Publications No. TR1. 3.2.2.3 TRANSFORMER CORE A five -legged core -coil assembly or three separate core -cal assemblies shall be employed. The use of three-legged designs is expressly prohibited. 7 368-300 Opal Dick- 368dash30O.pdf Page 8 REV. SYM: MM 3.2.2.4 HIGH VOLTAGE TAPS A no-load tap changer with external operating handle shall provide two 2 Y2 full capacity taps above and below normal. The operating handle shall be mounted in the primary compartment. 3.2.2.5 BUSHING WELLS AND TERMINALS 3.2.2.5.1 The number, location, and arrangement of bushing wells, terminals and parking stands shall be as shown in Fig. 1 and Fig. 5 of this specification. All low -voltage bushings and higlrvoltage wells shall be externally clamped and shall have leads of sufficient length to allow them to be changed without removing he cover. Welded bushings and wells are expressly prohibited. 3.2.2.5.2 High -voltage bush ng wells shall be 200A load -break interface 8.N14.4 kV bushings in accordance with ANSI/IEEE Sid. 386. 3.2.2.5.3 Low voltage bushing arrangement and spacing shall be "staggered', as shown in Fig. 5 of this Specification. 3.2.2.5.4 The low -voltage neutral shall be a fully insulated bushing. A ground pad shall be provided on the order surface of the tank and a removable copper ground strap shall be provided and connected between the low -voltage neutra I bushing and the ground pad. 3.2.2.5.5 The high -voltage neutral shall be connected to the low -voltage neutral internally with provision for opening this connection for testing. 3.2.2.6 ACCESSORY CABINET 3.2.2.6.1 The accessory cabinet shall consist of a high -voltage and low- voltage compartment generally constructed in accordance with applicable ANSI specifications and dimensioned in accordance with Fig.1 of this Specification. 3.2.2.6.2 Cabinet doors shall be hinged, removable, and lockable. Stainless hinge pins shall be provided. 3.2.2.7 ACCESSORY EQUIPMENT Accessory equipment shall be provided in accordance with Table 1A and the following details: 3.2.2.7.1 Suitable jack bosses or equivalent jacking facilities shall be provided on the tank. Vertical clearance for a jack shall be 11/2 inches minimum, 3Y= inches maximum. 3.2.2.7.2 The transformer base shall be arranged for rolling in two directions: Parallel to and at right angles to the centerline of the higlrvoltage bushings. 3.2.2.7.3 Far lifting lugs shall be provided. These lugs shall be adequate strength and size and arranged on the tank to provide a suitable lift for the completely assembled unit. 3.2.2.7.4 The base of the assembly shall be provided with suitable means for mounting the unit on the pad. An internal flange shall be provided at the base of the accessory compartment to provide means for mounting the unit on the pad. (Fig. 1). 3.2.2.7.5 Terminal designations are shown in Figure 1. The identification of terminal connection shall be shown on the instruction nameplate. Instruction nameplate shall be corrosion resistant, located in the low -voltage compartment, and shall be readable with cables in place. Where the nameplate is mounted on a removable part, the manufacturer's name and transformer serial number shall be pemnanerlly affixed to a non -removable part. Instruction nameplate shall contain the informal ion specified in ANSI C57.12.00-2000, paragraph 5.12. In adddion, either on the nameplate or label affixed near it, the manufacturer shall indicate that the dielectric fluid is nort-PCB. 8 368-300 Opal Dick- 368dash300.pdf Page 9 REV. SYM: MM 3.2.2.7.6 An automatic pressure relief device shall be located within the compartment. This device shall meet the following requirements: /:' NPT or larger male Inlet Pat. Exposed pans of weather and corrosion resistant materials. Non-deterioratin g gasket and o-ring material. Manual pull ring able to withstand 25 pound force minimum. Body able to withstand 100 pound force minimum. Bug shield. Cracking pressure of 10 t 2 psig. Resealing pressure of 6 psig minimum. Zero leak rate from resealing pressure to —8 psig. Minimum flow rate of 35 SCFM at 15 psig. 3.2.2.8 OILPRESERVATION Transformers shall be of sealed -tank construction. Sealed -tank construction is that which seals the interior of the tank from the atmosphere, and in which the gas plus the oil volume remains constant. The transformer will remain effectively sealed for a top -oil temperature range of —32°C to 105°C. 3.2.2.9 TANKS The tank shall be domed or sloped to shed water and shall be of sufficient strength to support a minimum of 500 lbs. Construction of the tank shall be in accordance with ANSI C57.12.26-1992, Section 7, except bolted cover is preferred. 3.2.2.9.1 If main cover is welded, adequate handhole(s) shall be provided. Handholes shall be concealed. Bolted -on covers shall be adequately gasketed and tamperproof. Main cover bolts may be exposed; however, where cover bolts are exposed, the comer bolts shall be welted or otherwise rendered tamperproof. 3.2.2.9.2 Tank grounding provision shall be in accordance with paragraph 7.6.4 of ANSI C52.12.26-1992. 3.2.2.9.3 Locking bolts shall be pentahead style. 3.2.2.10 OVERCURRENT PROTECTION Overcurrent protection shall consist of a single element current sensing bay-o-net fuse link in series with an ELSP currerlt limiting backup fuse. Fuses shall be sized as shown in Table 2: Tahia 2 — Fusina Ranuiramantx Expulsion 'Fuse Conttnuous Current Limiting Fuse Stock WA Current Rating Contlnudua<Current-Rating Number Ca acl (Part Number*) mart Nu bar' 36&304008 75kVA "A 30A 36&30b009 4000353C06 354403OMi1M I' V" I 113544040M 368-30D-016 (4000353C0e) ItA 368-300-030 300kVA 254 654 368-MG-031 4000353C10 3544065M61 368-300-D51 MVA 40A 10DA 4000353C12(3544100WIKM 368.30D 075 75OkVA 65A 125A 368-300-076 75MVA (40DO353C 14) (35441251V714 368-300-10D 1000kVA 368-300-101 1000kVA 120001NA I14000353C17) I(3544125M)1M1125A fuses 368-300-201 368-300-251 12500kVA 1125A Hi-Arrp OL Unk C05CB r 1250A : Parallel 1254 fuses (3544125Mr1M) Fuse shall be as specked in the table above or shall be an equivalent as approved in writing by Electric Standards Engineering. 9 368-300 Opal Dick- 368dash300.pdf Page 10 REV. SYM: MM 3.2.2.11 COMPONENTS FOR LOOPED PRIMARY The minimum current -carrying capability of components for the looped primary cable system shall be 200 amperes (continuous) and 10.000 amperes symmetrical (momentary). 3.2.2.12 AUDIBLE SOUND LEVEL The audible sound level shall be in accordance with NEMA Standard TR1. 3.2.2.13 BASE PLAN The base plan of a completely assembled unit shall be such that A can be installed on a pad of the dimensions shown in Fig. 6 of this specification. 3.2.2.14 PAINT 3.2.2.14.1 Surfaces to be painted shall be blast cleaned (commercial blast) to provide a clean dry surface free of dirt, dust, chalk, loose paint, rust, grease and any other contaminants. 3.2.2.14.2 EEI "Finishing Guidelines" specification shall apply. Finish coat shall be Desert Tan, Munsell #10YR6.013.0, glossy. 3.2.2.15 SAFETY LABELS The manufacturer shall not apply NEMA 260 Safety Labels. The Purchaser will apply custom warring labels after delivery. 3.2.2.16 ANGULAR DISPLACEMENT: Per Fig. 10(b) of ANSI C57.12.26-1992. r Opal Dick - 368dash300.pdf Page 1 L BELawd a I I A's NIN + �+—V + r 4 I 27.0 FLANGE 31T MIN 1 11T MAX KVARATINGS LOWVOLTAGE RATINGS COMPARTMENT UMEMIONS (MINIMUM) BUSHING HEIGHT A• B 7blw ALL 231M 27 T1S500 ALL n 31 7561000 iaIYW7,Z8Y 11ID R 4:1 15W.2500 ABOVlzz7 28 CB NOTE: D aed., insHe Amensbu. See Fg.5 Al Sena n (inc8es�. Mft m= gh,e lass shag al- arse bite dear a Iran edge M W (Fg. 6), MIN' Figure -Accessory compartment &Bushing Dimensions (Config. 1) REV. SYM: MM 11 368300 Opal Dick - 368dash300.pdf Page 12] -2.65 hit N.._.. TANK SFIRF. CE r i. TANK SUR FACE i 1 , ff I 1R c I c 4 1-lie0 I0.79 _j INSIDE Cable Accessory Patkinj; Sty l Figure I —Cable Accessory Parking Stand Detail [: =2(Config.) - DELETED 7/92 Figures 3 & 4 - DELETED 11/00 Ref. now to: ANSI C57.12.26 - 1992 figures 9(a) & 9(b) REV. SYM: MM 12 368-300 Opal Dick- 368dash300.pdf Page 13 REV. SYM: MM 4.0" A A A 4.0" 6" RADIUS IN MIN TYPICAL 3 PLACES r CL X1 X3 I B rr r rL �\ XO ` k\ X2 �r KVA RATINGS LOWVOLTAGE RATINGS A B 75-150 ALL 4.75 8 225-500 ALL 6 8 750-2500 480/277, 208Y/120 6 10 Figure 5- Staggered Low -Voltage Bushing Arrangement (all dimensions minimum inches). NOTE: An area having a 6 inch radius around each bushing shall remain clear of obstructions such as gauges, etc. 13 368-300 Opal Dick - 368dash300.pdf Page 14-1 REV. SYM: MM KVA I SERIAL I PAD DIMENSIONS (inches) A I B C D E F 75 -M thru -M 75 55 40 21 15 61 150 -015 75 55 40 21 15 61 150 -016 75 55 40 21 15 61 300 -030 75 55 40 21 15 61 300 -031 75 55 40 21 15 61 500 -050 75 55 40 21 15 61 500 -051 75 55 40 21 15 61 750 -076, -075 85 72 49 23 15 67 1000 -101,-100 85 72 49 23 15 67 1500 -151 101 87 51 23 15 j 76 2000 -201 107 88 51 23 15 79 2500 -251 107 88 51 23 15 79 Fig.6 - Pad Dimensions 14 36&300 Opal Dick - 368dash30O.pdf rt Page 1 REV. SYM: MM TABLE to ACCESSORY EQUIPMENT ACCESSORY I KVA 75450 300 500-2500 Tap changer handle in HV compartment X X X Irslruction nameplate in LV compartment X X X Jacking provisions X X X Provisions for rolling in two directions X X X Lifting lugs X X X Provisions for mounting on pad X X X Arrester moulting provisions Grounding provisions in both compartments X X X 1" oil drain plup X 1"oil drain valve with sampling device X X Upper filter press and filling plug (or cap) (f) X X X Provisions for oil gauge X Provisions for pressure -vacuum gauge X X Oilgauge X Thennorneter X X X Secondary CT mounting holes (4 holes on 4 318" x 5 5 8" centers) X X X Manual/automat is pressure relief valve X X X 15 368-300 Opal Dick - 368dash300.pdf Page 16 REV. SYM: MM 3.3 SPECIFIC REQUIREMENTS FOR DESIGN OF RADIAL -FEED Units 3.3.1 FUNCTIONAL DESCRIPTION The transformer shall be a three phase, pad mounted, radial feed safe break, "deadfrord" type for use on a 13.8 W grounded "Y" distribution system. 3.3.2 DESIGN AND CONSTRUCTION The requirements for radial -feed transformers shall be the same as those of loop -feed with the following exceptions: 3.3.2.1 RATINGS Tahln 9 _ RaAhl_Pmd Transforrin o-e Low Stock No. WA Voltage Impedance Bushin T e/Conft . High Volta a Low Voltage 366-300- 006 75 208Y/120 1 9% d f h 368-300- 007 75 1 480Y/277 1 9% d I f h d Per Figures 5A, & 7 of ANSI C57.12.26-1992 (In -Line) EXCEPTION: high voltage bushings shall be 32 .36 inches above the base of the transformer If Figures 9(a) & 9(d) of ANSI C57.12.26 -1992 (stud with 4-hole pad) h Figure 8(a) of ANSI C57.12.26-1992 (Staggered) 3.3.2.2 ACCESSORY CABINET The accessory cabinet shall be dimensioned in accordance with Fig. 7 of ANSI C57.12.26-1992. 4. QUALITY ASSURANCE 4.1 GENERAL 4.1.1 RESPONSIBILITY FOR INSPECTION Unless otherwise specified, the vendor is responsible for the performance of all inspection requirements as specked herein. Except as otherwise specified, the vendor may utilize his own facilities or any commercial laboratory acceptable to the City of Fort Collins. The City reserves the right to perform or witness any of the inspections set forth in this Specification where such inspections are deemed necessary. 4.1.2 TEST REPORT The manufacturer shall furnish to the purchaser certified copies of the results of all tests prior to payment. Copies shall be send to the Design Section as well as with the invoice. Unsigned copies are riot acceptable even if accompanied by a signed cover letter. The Quality Control Manager shall review and sign each test report. 4.2 TEST CONDITIONS Unless otherwise specified, testing defined in Section 4.6 shall be conducted under the following conditions: 4.2.1 REFERENCE TEMPERATURE The reference temperature to which losses, impedance, regulation, and efficiency are corrected shall be 850 C. 4.2.2 TOLERANCE ON IMPEDANCE VOLTAGE Tolerance shall be as specified in ANSI C57.12.00. 16 368-300 Date: 08/04/06 I n City of Fort Collins Page Number: 2 City of Fort Collins Purchase Order Number: 6604953 Delivery Date: 03/16/07 Buyer: DICK,OPAL Purchase Order number must appear on invoices, packing lists, labels, bills of lading, and all correspondence. Note: Line Qty UOM Description Unit Price Extended Price ACCORDANCEWITH STATED INDICES IN PRICING. ANY INDEX ESCALATION (INCREASE) AFTER THE QUOTED DELIEVERY DATE WILL NOT BE ALLOWED. NO LOAD LOSS - 924 FULL LOAD LOSS - 2346 TOTAL LOAD LOSS - 3270 IMPEDANCE 3.04% DELIVERY: 32 WEEKS OR CITY OF FORT COLLINS MAY CONSIDER THE CAPACTIY PLAN ARRANGEMENT AS PROVIDED IN THE QUOTATION FOR THESE UNITS WITH SPECIFIC SHIPMENTS AND QUANTITIES TO BE STATED WITHIN THE NEXT Opal Dick - 368dash300.pdf Page 177 REV. SYM: MM 4.2.3 TOLERANCE ON IMPEDANCE VOLTAGE ON A TAP The percent departure of tested impedance voltage on any tap from tested impedance voltage at rated voltage shall not be greater than the total tap voltage range expressed as a percentage of the rated voltage. 4.3 FUNCTIONAL TESTS Functional tests shall consist of those tests and related requirements as cross referenced in Table 4 and shall be performed on each unit, except Temperature and Noise Tests which shall be performed on one unit of each design (KVA) per order. Tn Mtn A C......N T TEST TEST PARAGRAPH REQUIREMENT ;OR'REFERENCE Examination Of Product 4.6 3.0 3.1 3.2 3.3 hisspecification) Ratio 4.6 ANSI C57.12.00 Section 8 Polarity Arid Phase Relation 4.6 ANSI C57.12.00 Section 8 Excitation Loss 4.6 ANSI C57.12.00 Section 8 Excitation Current 4.6 ANSI C57.12.00 Section 8 Impedance & Load Loss 4.6 ANSI C57.12.00 Section 8 TemDerature Tests" 4.6 ANSI C57.12.00 Section 8 Dielectric Tests 4.6.1 is s cation Impulse Tests 4.6.2 3.212.2 hiss ifrcation Leak Testing 4.6.3 1 3.2.2.8 & 3.2.2.9 (This specification) Noise Test . 4.6.4 1 3.2.2.12 hiss ifrcation une urn per design per omer. 4.4 TEST METHODS -- FUNCTIONAL TESTS Each completed unit shall be inspected to determine compliance with respect to dimensions, material, workmanship, construction and marking, and routine tests on all units shall be made as specified in Section 8 of ANSI Standard C57.12.00, and in ANSI Standard C57.12.90. In addition to rouline tests, the following test requirements arKVor modifications shall apply. 4.4.1 DIELECTRIC TESTS Induced and applied potential Dielectric Tests shall be performed in accordance with ANSI C57.12.00 and C57.12.90. The low voltage windings shall have a test potential to ground of 10,000 volts for one minute. The test potential between high voltage windings shall be 34,000 volts for one minute. 4.4.2IMPULSE TESTS ANSI Standard Impulse Tests shall be performed. Full Wave Impulse Test shall use a 1.5 x 50 microsecond wave. 4.4.3 LEAK TESTING The transformer tank shall be filled with oil and tested for air and oil leaks under (1) 4 psig vacuum for % hour, (2) 7 psig pressure for 24 hours in the sequence indiicated. An alternate method of leak testing may be performed by iryecting halogen gas under 10 psig and detecting leaks through the use of a halogen detector. (Note, the automatictmanual pressure relief device must be removed for this test). 4.4.4 NOISE TESTING Noise testing shall be conducted in accordance with applicable NEMA Standards. 5. PREPARATION FOR DELIVERY Transformers shall be prefilled with the appropriate amount of transformer oil and shall be shipped by open -bed trick. Units shall be packaged in such a way as to provide for ease of handli rig and to protect units from shipping damage. Units shall be fully palletized in four-way universal pallets with29' minimum openings to facilitate handling from any side. Pallets shall be independent of the transformer. The Supplier shall give 24-hou notice prior to delivery for any shipments where an individual transformer weighs over 4,000 pounds. In addition to these requdrements, the Supplier shall comply with any additional requirements or modifications shown on the purchase order arKVor supplemental instructions. 17 3W300 Opal Dick - 368dash300.pdf Page 18_ REV. SYM: MM 6. DEFINITIONS AND ABBREVIATIONS • Vendor or Supplier- The manufacturer andlor manufacturer's agent supplying or quoting on the specified article. • Article, Unit, Assembly - All refers to the equipment defined by this specification. DC or d.c.- Direct Current. • AC or a.c. - Alternating Current. • °C- Degree Celsius (Centigrade) • OF - Degree Fahrenheit • kV -1000 volts. • CPS or Hz -Cycles per second. psig -Pounds per square inch gauge. • V ory -Volts. • kVA -1000 Volt-amperes. 18 368-300 Opal Dick - 36-8dash300.pdf Page 19 REV. SYM: MM APPENDIX A Typical pad designs are shown in Figures 1A through 3,k The dimensions in inches of Figures 1A through 3A Wil fit the mirdmum compartments on transformers covered by this Specification as well as the maximum transformer envelope. 19 368-300 Opal Dick - 368dash300.pdf Page 20 REV. SYM: MM _ I I3" I PRIYNtY SEC. 3' 6' FRD r ' 27- 13• 19' a3 LENLLEND fW NQ fD wI WID7N 10" d0' — 3' 7 5T/9' Lr3. }- T T Noted on Pad World — I. Co+creb moot be3.ODD ver mninurn. ] Ir)aeinum coulee DgWeaote dra 1 1/2 idles 9page rewirements far Pad Cnd primary a ntnng cabinet Fill generally be V X 12'. Faclars to he twmtacpt fdarmi In iq the Pod rock da — 1. Aeftseblity — Ina Udn l"er pod anal at aCCeeefaU to line boon trucha eaufpped la the installation and removul of heavy tranafarMoM $tads aeesddWlity shall not tegvia mlrusmn a odj wt Prapeny. 2 Prosinity of Buadinga. dale. Darriea. and/or Ovarhmge — m adaalm to the rtaarmrad raqured IS, Fdtdtaum and nmoyd. the mninum elwwl w n front of the bonaformet pod shot be eight (8) feat and the mhinum clearance from al otrs ddm anal be tree (S) test If the aulldnq has on e1411%en9, dwenae IS the alga of the bvinsformar Pad shah be measured hurimntally from the wtar edge of the overhang. Tronofarmss through 300 KVA may be installed undsd the avemanq if the Yort"I dwanro bet✓bith ins Poe and the ovfmohe is all le let 25 foot wA the faddtlun is weeesible to line boom truohe J. Codn and Standards — In uddtt'tm to the oboes. the Installation dhrtl conform to the Notlm l Electric Cade and hderut note arW ray mars are slu+mras. 2 S 25 93 REV NO. DATE OWN D.E. APP MO. ENG ADD DIST ADP CITY OF FORT COLLINS DWG 3PHASEI LIGHT AND POWER DEPARTMENT TRANSFORMER PAD DESIGN 75 — 500 KVA leeerr one �0� 3 PHASE Figure IA- Pad Design (76 - 500 KVA) 20 368-300 Opal Dick - 368dash300.pdf Page 21 REV. SYM: MM l I I I I I I 72' - I—�----i--�-- I' -mot. 3 17' I PRINARY SEIbNS6tiY 8. I av— +IT 1 1 Tr ��— 1H' 26" or tir —+I rotsw e7 otiva 49,3' L04GI. Mdl VtalY 7 3/0 —t— 47 Noted an Pro I,lotafnl — 1. Crtt, mutt be 3,000 Per mrnrnum. 2. o..um anoes oggepats sbe 1 112 novae a requirements fdf pad and Pi.nory fowlehrnq edbnot 0111 q"aIr M B' x 120. rectors to on, owzmweo fn facet rig the Pod InC1Yae — f ACcetaatity — the tmosiMmer pod snot ppe ecceatae 10 P line boon trudm eauidaed far fnetolo4b,l ad removal of heOty IrorMfoemsR. Such dec,"emy Mal not raep's nt.an on odlownt FWCPWIy. 2. Rotnnoty of B.rLatnyys. *thus Barriers, and//air Overr"s — ti addition to the doaronced rew1 ed for ineluloUo, wet remand, the Mn1hYM assrdles br front of the 1ra56farMw Pad "I de dgnt (a) feet end Ina Mlnrmam oecrorce tam all other tides shot ter four (1) test, If the "dilq hot on aY,mom) eldoreneo to the edge of the transforms, Pod enrol be mouslrrad horIzontolly ceva corn the outer adpe of the rhanp. rrervformerd t rowel, 300 KVA moy be w0clied under the onarnonq o the Ydltca clorwonae brelYolen tno Pod wo ins onahod9 fs of host 25 feel and the lowbou is arcesalde to lels boom trucks 31 Codes and Slondtrds - in odiiInn, to the above. the neidfolydl "I Conform to the filit,431101 EIWIhC Code Ma federal, state wd city Lodes and standorda. 1I 02 BO REV NO. OATE D D,E, APP DS G E G APP DIST, APP CITY OF FORT COLLINS DWG 3PHASE2 LIGHT AND PO ER QEPARNENT TRANSFORWR P p OESIG 500 — 1000 KVA 3 PHASE Figure 2A - Pad Design (500 -1000 KVA) 21 368-300 Opal Dick- 368dash300.pdf Page 22� REV. SYM: MM --I -1-4-� I-- �- I� 15' PRIMARY WINDOW SC[WDARr B" -- —� — 2B' 23' V. 29' II FIVE ss REPAR VI 31• L[NGIM AND Wl Dllp 3" AND 3' 7 5/9- -F t Not" on pad ildwo - 1,Sc,Ynalete marl no S.ODD psi minmum. 2, 1( nim cast" owegato Sao 1 1/2 inches, space raqulhammm by POD end Primary lh+lchrg co%net *1 gmeroly be 9' % 12'. Foekon to be coneidored in locotlrq the pod :+clods - 1. AenNl4ty - rha Lranafoi~ Pea Shop be oteouOY to Nia boom trucks ewbped for the instalotim and raaaml of a" Vpnilprerp'a Sum orcma ley snail rat ragbo inkra9lm a odpcenk property. 2 Prodmily of Blr[dnge, l Whet Borriora, wd/w Overhangs - In od3lion to the cleowcm reti.had for inetdlalion and remow1, the mimmnu eMvorao in Iledt er the irOMlaimm pad %boll tee light (8) 1wl and the mmraam doeronce from all other sire Shall he 1" (4) feel If the baildbq has on amain, r:MlanrJ to ME od" of me trenstermer Pad "I be msosurod horirw,tely train the Dater edge 91 the overhong. rrmrferrrlWE thiO qn 7W MVA may on y0141W under me ovr"" it lea YrrdEal de>ereo Wtjam in$ Pod and Inn ovsharq is of least 25 fist and the I=Von is occeedble to Inr boom traate. S. Cadn as stanryde - h addition to the asoye. the matelelim shall twform to the Not End Deere ends and fadrd, slots and ally codm and atomb 11/02/90 REV N0. OATE 0 N D.E. APP DSNG. ENG APP DIST. APP CITY OF FORT COLLINS DWC 3PHASE3 LIGHT AND POWERDEPARDEPARTIyIENT 11300 - 2500 KVA w-�• ••�••• gorses r �ar� 3 PHASE Figure 3A- Pad Design (1000-2500 KVA) 22 368-300 Opal Dick - 368dash300.pdf Page 23 REV. SYM: MM APPENDIX B Transformers purchased under this Specification shall be of the make shown below. Manufacturers not listed below may submit written proposals demonstrating compliance with these Specifications for consideration of addition to the accepted manufacturer list prior to the next request for bids. In addition to inclusion on the list below, manufacturer's equipment must also satisfy all requirements of this Specification to be acceptable. TABLE 3B MANUFACTURER SERIAL NO. Cooper Power Systems At ASEA Brown-Bovari (ABB) All Howard Industries All Pawaels Transformers All The manufacturers in the following list have been conditionllyapproved and may bid as an aftemate. The definition and intent of "Conditional Approval" of a manufacturer is to allow the City to gain some experience with the manufacturers product. Should a conditionally approved manufacturer be the evaluated low bidder, the City reserves the right to award all, part, or none of the order to them, dependant upon the current feeds of the City for that item or items. 23 368-300 Opal Dick - 368dash300.pdf Page 24] REV. SYM: MM APPENDIX C The following fors for Individual and Average Transformer Losses are used by the City of Fort Collins to determine loss pennies. 1) Transformer Loss Evaluation Average Losses For 2) Individual Transformer Loss Evaluation For 24 368-300 Opal Dick - 368dash300.pdf Page 25 REV. SYM: MM TRANSFORMER LOSS EVALUATION -AVERAGE LOSSES City Order No. SIN Manufacturer Invoice No. WA/Unit LINE DESCRIPTION AMOUNT (1) No. of units (2) Average core losses (3) Quoted core losses (4) Excess average core losses: line (2) less line (3) (5) Penalty for excess average core losses: line (1) x line (4) x $ (6) Average copper losses (7) Quoted copper losses (8) Excess average copper losses: line (6) less line (7) (9) Penalty for excess average copper losses: line (1) x line (8) x $ _ (10) Penalty to be assessed manufacturer: line (5) plus line (9) but not less than zero Date Prepared By: Design Engineering NOTE: If any unit(s) exceeds the loss tolerances of ANSI C57.12.00, Light & Power will either reject it, include it on these averages, or calculate losses using the Individual Transformer Losses Evaluation Form, whichever is most favorable to Light and Paver. 25 368-300 Opal Dick - 368dash300.pdf Page 26 INDIVIDUAL TRANSFORMER LOSS EVALUATION City Order No. Manufacturer KVA/Unit LINE DESCRIPTION (1) _ Tested core losses (2) Quoted core losses (3) Excess core losses line (1) less line (2) but not less than zero (4) Percent difference Line (3)—line (2) x 100 (5) Tested total losses (6) Quoted total losses (n Excess total losses Line (5) less line (6) but not less than zero. (8) Percent difference Line (7) -a- line (6) x 100 (9) _ Tested copper losses (10) Quoted copper losses (11) Excess copper losses Line (9) less line (10) but not less than zero. (12) Penalty for excess core losses Line (3) x $ (13) Penalty for excess copper losses Line (11) x $ (14) Penalty to be assessed manufacturer Line (12) plus line (13) SIN Invoice No. Date Prepared By: Design Engineering AMOUNT REV. SYM: MM 26 368-300 Date: 08/04/06 City of Fort Collins Page Number: 3 City of Fort Collins Purchase Order Number: 6604953 Delivery Date: 03/16/07 Buyer: DICK,OPAL Purchase Order number must appear on invoices, packing lists, labels, bills of lading, and all correspondence. Note Line Qty UOM Description Unit Price Extended Price 7 CALENDAR DAYS BY WESCO Total $133,760.00 City of Fort C1411ijs Director of Purchasing and Risk Management City of Fort Collins This order is valid over $2000 unless signed by James B. O'Neill 11, CPPO, FNIGP Accounting Department City of Fort Collins Purchasing, PO Box 580, Fort Collins, CO 80522-0580 PO Box 580 Fort Collins, CO 80522-0580 e Opal Dick- 368dash300instructions.pdf Page 1 Revised 12/13/96 Special Conditions and Supplemental Instructions to Bidders Applicable to Specification 368-300 A. Data to be supplied with Bidder's Proposal The following data shall be supplied with the bidder's proposal in addition to that information required by the "Invitation to Bid" and the "Purchase Requisition". 1. Impedance volts in percent (%) at full load, high voltage to low voltage at 85°C 2. No load and total losses at 85°C 3. Delivery in weeks 4. A statement indicating compliance with our Specification with exception or a detailed list of exceptions. 5. Escalation IS / IS NOT applicable for the transformers bid. If escalation applies, the Bidder shall indicate in his bid, the specific items or materials subject to escalation and shall provide the method and indices to be used in computing the amount thereof. Escalation occurring after acceptance, if Purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid. If the above information and compliance statement are not supplied the proposal will not be evaluated An alternate bid for the total order may be submitted in addition to the unit bids. B. Loss Evaluations Loss penalties and loss evaluations will be based on the following values: 1. No-load or excitation losses at $3.90/watt 2. Load losses at $2.30/watt C. Shipping Terms Ship F.O.B. point of destination, freight prepaid. D. Terms of Payment l . If escalation applies, the City of Fort Collins shall not be billed for escalation occurring after the promised delivery date. 2. Test reports shall accompany the invoice. If test reports do no accompany the invoice, late payment penalty charges incurred due to delays in obtaining the test reports will not be paid. Certified copies of test reports shall be sent to the Standards Engineering Section, Fort Collins Utilities - Light & Power. 3. Loss penalty credits and escalation charges shall be itemized on the invoice. Opai Dick - 368dash300.pdf Page 1 THE CITY OF FORT COLLINS Light and Power Department P.O. Box 580 Fort Collins, CO 80522 SPECIFICATION NO: 368-300 TITLE PAD -MOUNTED COMPARTMENTAL-TY PE,THREE-PHASE DISTRIBUTION TRANSFORMERS VNTH SEPARABLE INSULATED LOAD BREAK HIGH -VOLTAGE CONNECTORS i APPROVED BY: Kraig Bader Standards Engineering Division Manager - ORIGINATION DATE: 8/12/83 REVISED: 2/2/2005 Opal Dick - 368dash300 pdf Pale 2 REV. SYM: MM ITEMS COVERED BY THIS SPECIFICATION DESCRIPTION STOCK NO. SPECIFICATION NO. SERIAL 75 KVA 20BY/120 RADIAL 368.300 -m 75 KVA 408Y/277 RADIAL 368-300 -007 75 KYA 208Y/120 LOOP 368-300 -008 75 KVA 480Y/277 LOOP 368-300 -009 150 KV& 208Y/120 LOOP 368-300 -015 150 KVA 480Y/277 LOOP 368-300 -016 300 KVA 208Y/120 LOOP 368-300 -030 300 KVA, 480Y/277 LOOP 368-300 -031 500 KV& 208Y/120 LOOP 368.300 -050 500 KVA 480Y/277 LOOP 368-300 -051 750 MA 20BY1120 LOOP 3W30D -075 750 MA 480Y/277 LOOP 368-300 -076 1000 KVA 20BY1120 LOOP 368-300 -100 1000 MA 4BOY/277 LOOP 368-300 -101 15W KVA 4BOY/277 LOOP 368 300 151 2000 KVA 480YI277 LOOP 368-300 -201 2TOO KVA 480Y/277 LOOP 368-300 -251 2 368-300 Opal Dick - 368dash300.pdf Page 3 REV. SYM: MM REVISION DESCRIPTIONS REVISION DESCRIPTION Previous onflle APPROVED REVISION FF: Tim Sagen Add Paragraph 5.2.2.9.3: pentahead locking bolts Susan Coram Paragraph 3.2.2.13.1: add glossy requirement. 10-18-95 REVISION GG: Susan Coram Title page: Remove revised date Tim Sagen Paragraph 4.4 and Table 2A Change Temperature Tests and Noise Test from every 9-22-95 unit to one unit of design. REVISION HH: Opal Dick GE removed from Appendix B Tim Sagan 12-13-96 REVISION II • Add paragraph 3.2.2.10 OVERCURRENT PROTECTION and renumber remaining paragraphs in section 3.2 Opal Dick • Revise Fig. 1 to reflect a "V" configuration for the primary bushing arrangement vs. an Tim Sagen in -line arrangement. 613199 • Revise Fig. 17 to remove requirement for CT mounting studs and increase drnansions A from 5' and 5.5" to 6" on 225-25W WA sizes REVISION JJ Bill Bray Reformat and converted to MS Word, delete List of Active Pages Tim Sagan 911412000 REVISION KK Kraig Bader Added drawing la to describe cable accessory parking stand detail, revise to reflect Tim Sagen current editions of national standard s, change impedance on 368-300-009 from 9 / 11 / 2001 1.7% to 1.9%. REVISION LL Kraig Bader • Charge fusing from oil -immersed cwrent sensing weak link cartridge to a current 4/212004 sensing bay-o-net fuse fink in series with an ELSP current limiting backup fuse (clause 3.2.2.10). • Charge column header for impedance table in 3.2.2.1 to clarify that impedance numbers are nominal values. (Tolerance s are consistent with ANSI C.57.12.00- 2000) • Charged wording from "Mr. Ouch" in 3.2.2.15 to "warring label" Revision MM Kraig Bader Change clause 3.2.2.10 to specify current sensing bay-o-net fuse link by size and 212/2006 part number. Table 2 was added for this pupose. Renamed table in 3.3.2.1 to from Table 2 to Table 3 Renamed table in 4.3. from Table 2A to Table 4 3 368-300 Opal Dick- 368dash300.pdf Page 4 REV. SYM: MM TABLE OFCONTENTS ITEMS COVERED BYTH IS SPECIFICATION ... ........... ............. ._........... ...... _.... ... ....._....... ......... ...... ........ 2 REVISIONDESCRIPTIONS ...... _........ _... ....... ....... ...... . ............. .............. ............ ..... ......... ____ ............. .....__3 1. SCOPE ... .......... .............. .._.......... .............. ............... ... ....... .... ................ .............................. ... ........ ... .............. ............... ..5 2. APPLICABLE DOCUMENTS..._. ..... _ ._.. .............. .............. ..... ._....... _.___._... _.. __..._ ....__._... ... _ .. .___ .. _.5 3. REQUIREMENTS ._......_.r. ___.._._... __._....._. ............ .. ............... ............... ............ ............... ............. .............. ..... _....... 5 3.1 GENERAL REQUIREMENTS FOR DESIGN .......... ................ ...... ... ...... ................-.............. ................ ................ ............... .......5 3.2 SPECIFIC REQUIREMENTS FOR DESIGN OF LOOP -FEED UNITS ........................... ................ ................ ................ .............7 3.3 SPECIFIC REQUIREMENTS FOR DESIGN OF RADIAL -FEED UNITS ........... ................ ......... ................ ................ ......16 4. QUALITY ASSURANCE ............ ............ ...... ............... ... ........... ............. .... ..... .... .... ... ....... _.....__.._ .............. .16 4.1 GENERAL ................ ............... ................................................ ................ ................ .....16 4.2 TEST CONDITIONS ................ ................ ................ ................ ................ ................ ................................................ ................ .....16 4.3 FUNCTIONAL TESTS ........... ................ ................ ............... ................ ................ ................ ............... _.............. ................ .......17 4.4 TEST METHODS - FUNCTIONAL TESTS ................ ................ _............. ................ ................ ................ ................ ................ 17 5. PREPARATION FOR DELIVERY......_ _.___._.. .............. ............ ...... ....._..__. ._.._..... _.......__.._. ... .... __. ._.._..17 6.DEFINITIONS AND ABBREVIATIONS _._.......... _...... ...... ............. .............. ..__.._._. ......... ... . .............. ......_..... ......18 APPENDIXA ...... _..___.... _____.... ........... .............. ............. ._........... ..... ..... _...._.._._.. ...... __..... ._.._._.... APPENDIXB_____.._. ........... ............... ....... _............ ........... ._........__ .__....__ .__..23 APPENDIXC.__.__.. _._._.w.. __....___ .__.._._. ....._._._... _..__...._.. ._. ....... ........... _. ......___. .__..___ _.....24 TRANSFORMER LOSS EVALUATION -AVERAGE LOSSES .......................... ................ ................ ................ ................ .......25 INDIVIDUAL TRANSFORMER LOSS EVALUATION ...................... ................ ................ ................ ................ ................ ........26 4 368-300 Opal Dick - 368dash300.pdf Page 5 REV. SYM: MM SPECIFICATION FOR PAD -MOUNTED COMPARTMENTAL -TYPE, THREE-PHASE DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED LOAD BREAK HIGH -VOLTAGE CONNECTORS 1.SCOPE This Specification establishes the minimum electrical requirements and mechanical features of three phase, 60 HZ, mineral al immersed, self -coded, pad -mounted, compartmen tal4ype distribution transformers rated 2500 WA and smaller, high voltage 13,200 Grd Y17620 volts, with separab le insulated load break high voltage connectors. These transformers are used for step down purposes from an underground primary cable supply. This standard generally conforms to ANSI requirements for pad -mounted compartm ental-type, self -coded, three-phase, distribution transformers for use with separable insulated high -voltage connectors, C57.12.26. 2.APPLICABLE DOCUMENTS The following documents form a part of this Specification to the extent specified herein. The latest issue in effect on the date of invitation for bids shall form a part of this Specification, undess otherwise rated. • ANSI C57.12.00 - Distribution, power, and regulating transformers, and shunt reactors, general requirements for • ANSI C57.12.26 - Pad mounted, comparl mental-ty pe, self -coded three phase, distribution transformers for use with separable insulated high voltage connectors, high voltage 34,5W Grd Y/19,920 volts and below, 2500 WA and smaller, requirements for • ANSI C57.12.70 - Temunal markings and connections for distribution and power transformers • ANSI C57.12.80 - Terminology for power and distribution transformers • ANSI C57.12.90 - Distribution, paver, and regulating transformers, and shunt reactors, test code for • ANSMEEE 386 - Separable insulated connectors for pourer distribution systems above 600V NEMA STANDARD TR1 -Transformers, regulators and reactors 3. REQUIREMENTS 3.1 GENERAL REQUIREMENTS FOR DESIGN 3.1.1 BASIC DESIGN STANDARDS Transformers purchased under these Specifications shall be new and, unless otherwise specified, meet the requirements of the applicable ANSI Standards and the modifications and additions given in the subsequent paragraphs. In case of conflict, the requirements of the following documents shall apply in the priority shown: a) This Specification. b) ANSI C57.12.26 c) Other applicable ANSI and NEMA Standards. 3.1.2 KILOVOLT -AMPERE TEMPERATURE RATINGS Kilovolt -ampere ratings are continuous and are based on not exceeding either a 65°C average winding temperature or an 80°C hot spot temperature rise. The temperature rise of the insulating oil shall rat exceed 65°C when measured near the top of the tank. The temperature rise is based on an altitude of 3,300 feet. 3.1.3 GENERAL CONSTRUCTION 3.1.3.1 The pad -mounted compartmental-t ype transformers shall consist of the transformer tank, high -voltage cable terminating compartment, and the law -voltage cable-terninatin g compartment. All three of these components shall be assembled as an integral unit, tamperproof and weatherproof for mounting on a pad. There shall be no exposed screws, bolts or other festering devices, which are externally removable, except the main cover bolts may be exposed. Where the main cover bolts are exposed, the 5 368-300 Opal Dick - 368dash300.pdf Page 6 REV. SYM: MM comer bolts shall be welded or otherwise render ed tamperproof. There shall be no opening through which foreign objects such as sticks, rods, or wire s might be inserted to contact live parts. Suitable means for padlocking the compartment door(s) shall be provided. 3.1.3.2 The high and low -voltage compartment shall be located side by side on one side of the transformer tank. When facing the compartment, the low -voltage compartment shall be on the right. 3.1.3.3 Construction of the unit shall be such that it can be lifted, skidded, and slid into place on the mounting pad without disturbing the entrance cables. 3.1.3.4 An undercoating over the regular finish or an equivalent treatment shall be applied to all surfaces that are in contact with the pad to minimize corrosion. 3.1.3.5 Minimum dimensions shall be as shown in Fig. 1 of this Specification. Maximum transformer and minimum pad dimensions are shown in Fig. 6 of this Specification. 3.1.4 LOSSES The total losses of a transformer shall be the sum of the excitation losses and the load losses (12R losses). Load loss tests shall be performed and reported on all tints regardless of whether or not a record of such tests is available on duplicate units. Loss evaluation and loss costs will be based on the values shown in the "Special Conditions and Supplemental Instructions s to Bidders." Transformers will be evaluated on excitation losses and PR losses at the specified rates. If tested losses exceed quoted losses but are within the tolerances of paragraph 9.3. ANSI C57.12.00-2000, the additional cost incurred from the differential of losses will be calculated using the follawing equation and the above specified rates and will be deducted from the original Purchase Order or back charged to the manufacturer. In Table 18 and the following equation "Units" shall mean "Transforrmers of the same size and design on one order." Excess loss $ _ [No. of units] [(No Load Loss Evaluat ion $) (Avg. No Load Losses — Quoted No Load Losses) + (Load Loss Evaluation $) (Avg. Load Losses — Quoted Load Losses)]. If this equation results in a negative number no credit will be given the Supplier. If any unit or units exceed the tolerances of paragraph 9.3, ANSI C57.12.OD-2000, that unit or units shall not be shipped without express permission from the City. If accepted, the deduction for excess losses will be based on the following equation: Excess loss $ _ (No Load Loss Evaluation $) (No Load Losses — Quoted No Load Losses) But Not Less Than Zero + (Load Loss Evaluation $) (Load Losses —Quoted Losses) But Not Less Than Zero. 3.1.5 SERVICE CONDITIONS Service conditions shall be as defined in paragraph 4.1 of ANSI C57.12.00 except the ambient temperature range shall be 40"C above to 32°C below zero. The transformer shall operate safely with starting temperatures as low as 32"C below zero. 6 368-300